Measuring radio-signal power accurately
NASA Technical Reports Server (NTRS)
Goldstein, R. M.; Newton, J. W.; Winkelstein, R. A.
1979-01-01
Absolute value of signal power in weak radio signals is determined by computer-aided measurements. Equipment operates by averaging received signal over several-minute period and comparing average value with noise level of receiver previously calibrated.
Ahrens, T S; Schallom, L
2001-01-01
Techniques to measure pulmonary artery (PA) pressure waveforms include digital measurement, graphic measurement, and freeze-cursor measurement. Previous studies reported the inaccuracy of digital and freeze-cursor measurements. However, many of the previous studies were small and did not thoroughly examine the circumstances of when digital measurements might be inaccurate. To compare digital measurements and graphic measurements of PA and central venous pressure (CVP) waveforms in patients with a variety of respiratory patterns, and to compare digital measurements and graphic measurements of CVPs in patients with abnormal or right ventricular waveforms. A total of 928 patients were enrolled in this study. Waveforms from the PA and CVP were collected from each patient. The monitor pressure value (digital measurement) printed on the recorded waveform was compared with the pressure value obtained by a graphic strip recording and measured by one of the primary investigators (graphic measurement). Digital measurements were found to be inaccurate in measuring waveforms in all respiratory categories and in measuring right ventricular waveforms. PA diastolic values and CVP values were the most inaccurately measured waveforms. Digital errors of more than 4 mm Hg were common. There were instances in which the monitor's digital measurement was substantially different from the graphically measured value. This difference has the potential to mislead interpretation of clinical situations. The monitor's ability to occasionally give digital measurement values similar to the graphic measurements may lead to a false sense of security in clinicians. Because the accuracy of the monitor is inconsistent, the bedside clinician should interpret waveforms through use of a graphic recording rather than rely on the digital measurement on the monitor.
ERIC Educational Resources Information Center
Shah, Akhtar H.
2014-01-01
Many projects fail despite the use of evidence-based project management practices such as Performance Measurement Baseline (PMB), Earned Value Management (EVM) and Risk Management (RM). Although previous researchers have found that integrated project management techniques could be more valuable than the same techniques used by themselves, these…
Davie-Martin, Cleo L; Hageman, Kimberly J; Chin, Yu-Ping; Rougé, Valentin; Fujita, Yuki
2015-09-01
Soil-air partition coefficient (Ksoil-air) values are often employed to investigate the fate of organic contaminants in soils; however, these values have not been measured for many compounds of interest, including semivolatile current-use pesticides. Moreover, predictive equations for estimating Ksoil-air values for pesticides (other than the organochlorine pesticides) have not been robustly developed, due to a lack of measured data. In this work, a solid-phase fugacity meter was used to measure the Ksoil-air values of 22 semivolatile current- and historic-use pesticides and their degradation products. Ksoil-air values were determined for two soils (semiarid and volcanic) under a range of environmentally relevant temperature (10-30 °C) and relative humidity (30-100%) conditions, such that 943 Ksoil-air measurements were made. Measured values were used to derive a predictive equation for pesticide Ksoil-air values based on temperature, relative humidity, soil organic carbon content, and pesticide-specific octanol-air partition coefficients. Pesticide volatilization losses from soil, calculated with the newly derived Ksoil-air predictive equation and a previously described pesticide volatilization model, were compared to previous results and showed that the choice of Ksoil-air predictive equation mainly affected the more-volatile pesticides and that the way in which relative humidity was accounted for was the most critical difference.
Low-Value Medical Services in the Safety-Net Population
Linder, Jeffrey A.; Clark, Cheryl R.; Sommers, Benjamin D.
2017-01-01
Importance National patterns of low-value and high-value care delivered to patients without insurance or with Medicaid could inform public policy but have not been previously examined. Objective To measure rates of low-value care and high-value care received by patients without insurance or with Medicaid, compared with privately insured patients, and provided by safety-net physicians vs non–safety-net physicians. Design, Setting, and Participants This multiyear cross-sectional observational study included all patients ages 18 to 64 years from the National Ambulatory Medical Care Survey (2005-2013) and the National Hospital Ambulatory Medical Care Survey (2005-2011) eligible for any of the 21 previously defined low-value or high-value care measures. All measures were analyzed with multivariable logistic regression and adjusted for patient and physician characteristics. Exposures Comparison of patients by insurance status (uninsured/Medicaid vs privately insured) and safety-net physicians (seeing >25% uninsured/Medicaid patients) vs non–safety-net physicians (seeing 1%-10%). Main Outcomes and Measures Delivery of 9 low-value or 12 high-value care measures, based on previous research definitions, and composite measures for any high-value or low-value care delivery during an office visit. Results Overall, 193 062 office visits were eligible for at least 1 measure. Mean (95% CI) age for privately insured patients (n = 94 707) was 44.7 (44.5-44.9) years; patients on Medicaid (n = 45 123), 39.8 (39.3-40.3) years; and uninsured patients (n = 19 530), 41.9 (41.5-42.4) years. Overall, low-value and high-value care was delivered in 19.4% (95% CI, 18.5%-20.2%) and 33.4% (95% CI, 32.4%-34.3%) of eligible encounters, respectively. Rates of low-value and high-value care delivery were similar across insurance types for the majority of services examined. Among Medicaid patients, adjusted rates of use were no different for 6 of 9 low-value and 9 of 12 high-value services compared with privately insured beneficiaries, whereas among the uninsured, rates were no different for 7 of 9 low-value and 9 of 12 high-value services. Safety-net physicians provided similar care compared with non–safety-net physicians, with no difference for 8 out of 9 low-value and for all 12 high-value services. Conclusions and Relevance Overuse of low-value care is common among patients without insurance or with Medicaid. Rates of low-value and high-value care were similar among physicians serving vulnerable patients and other physicians. Overuse of low-value care is a potentially important focus for state Medicaid programs and safety-net institutions to pursue cost savings and improved quality of health care delivery. PMID:28395014
Van Norman, Ethan R; Nelson, Peter M; Klingbeil, David A
2017-09-01
Educators need recommendations to improve screening practices without limiting students' instructional opportunities. Repurposing previous years' state test scores has shown promise in identifying at-risk students within multitiered systems of support. However, researchers have not directly compared the diagnostic accuracy of previous years' state test scores with data collected during fall screening periods to identify at-risk students. In addition, the benefit of using previous state test scores in conjunction with data from a separate measure to identify at-risk students has not been explored. The diagnostic accuracy of 3 types of screening approaches were tested to predict proficiency on end-of-year high-stakes assessments: state test data obtained during the previous year, data from a different measure administered in the fall, and both measures combined (i.e., a gated model). Extant reading and math data (N = 2,996) from 10 schools in the Midwest were analyzed. When used alone, both measures yielded similar sensitivity and specificity values. The gated model yielded superior specificity values compared with using either measure alone, at the expense of sensitivity. Implications, limitations, and ideas for future research are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krieger, G L
1976-06-01
W (the average energy to form an ion pair) for 5.4 MeV /sup 241/Am alpha particles in a Rossi-type tissue equivalent (T.E.) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitizer were used to measure the current produced by completely stopping the alpha particles in a large cylindrical ionization chamber. A multichannel analyzer, operating in a slow multiscalar mode, was used to store pulses from the current digitizer. The dwell time, on the order of 60 minutes per channel, was selected with anmore » external timer gate. Current measurements were made at reduced pressures (approximately 200 torr) to reduce ion-recombination. The average current, over many repeated measurements, was compared to the current produced in nitrogen and its previously published W-value of 36.39 +- 0.04 eV/ion pair. The resulting W-values were (in eV/ion pair): 26.29 +- 0.05 for argon, 29.08 +- 0.03 for methane and 30.72 +- 0.04 for T.E. gas, which had an analyzed composition of 64.6% methane, 32.4% CO/sub 2/, and 2.7% nitrogen. Although the methane and argon values agree within 0.1% with previously published values, the value for T.E. is 1.2% lower than the single previously reported value.« less
499 E Illinois, November 2012, Lindsay Light Radiological Survey
Field gamma measurements did not exceed the respective field instrument threshold value previously stated andmaximum values observed at each lift ranged from approximately 10,700 to 12,600 cpm unshielded
Partitioning of fluorotelomer alcohols to octanol and different sources of dissolved organic carbon.
Carmosini, Nadia; Lee, Linda S
2008-09-01
Interest in the environmental fate of fluorotelomer alcohols (FTOHs) has spurred efforts to understand their equilibrium partitioning behavior. Experimentally determined partition coefficients for FTOHs between soil/water and air/water have been reported, but direct measurements of partition coefficients for dissolved organic carbon (DOC)/water (K(doc)) and octanol/ water(K(ow)) have been lacking. Here we measured the partitioning of 8:2 and 6:2 FTOH between one or more types of DOC and water using enhanced solubility or dialysis bag techniques, and also quantified K(ow) values for 4:2 to 8:2 FTOH using a batch equilibration method. The range in measured log K(doc) values for 8:2 FTOH using the enhanced solubility technique with DOC derived from two soils, two biosolids, and three reference humic acids is 2.00-3.97 with the lowest values obtained for the biosolids and an average across all other DOC sources (biosolid DOC excluded) of 3.54 +/- 0.29. For 6:2 FTOH and Aldrich humic acid, a log K(doc) value of 1.96 +/- 0.45 was measured using the dialysis technique. These average values are approximately 1 to 2 log units lower than previously indirectly estimated K(doc) values. Overall, the affinity for DOC tends to be slightly lower than that for particulate soil organic carbon. Measured log K(ow) values for 4:2 (3.30 +/- 0.04), 6:2 (4.54 +/- 0.01), and 8:2 FTOH (5.58 +/- 0.06) were in good agreement with previously reported estimates. Using relationships between experimentally measured partition coefficients and C-atom chain length, we estimated K(doc) and K(ow) values for shorter and longer chain FTOHs, respectively, that we were unable to measure experimentally.
Improved Technique for Finding Vibration Parameters
NASA Technical Reports Server (NTRS)
Andrew, L. V.; Park, C. C.
1986-01-01
Filtering and sample manipulation reduce noise effects. Analysis technique improves extraction of vibrational frequencies and damping rates from measurements of vibrations of complicated structure. Structural vibrations measured by accelerometers. Outputs digitized at frequency high enough to cover all modes of interest. Use of method on set of vibrational measurements from Space Shuttle, raised level of coherence from previous values below 50 percent to values between 90 and 99 percent
The production and escape of nitrogen atoms on Mars
NASA Technical Reports Server (NTRS)
Fox, J. L.
1992-01-01
The lack of agreement between our previously computed values and those measured by Viking of the N-15:N-14 isotope enhancement ratio has led us to reevaluate our model of the Martian ionosphere. In previous models, we were unable to reproduce the ion profiles measured by the RPA on Viking using electron temperatures that were higher that the ion temperatures. When we increased the electron temperatures to 2500-3000 K and with a zero flux upper boundary condition, the ion densities at high altitudes exceeded the measured values by a large factor. We found that we can better fit the observed profiles if we impose a loss process at the upper boundary of our model. If the horizontal fluxes of ions do not constitute a net loss of ions, then the escape of N due to dissociative recombination is also inhibited and better agreement with the measured isotope ratio is found. The production of escaping nitrogen atoms is closely related to the production of thermospheric odd nitrogen; therefore, the densities of NO measured by Viking provide a convenient check on our nitrogen escape model. Our standard model NO densities are less that the measured values by a factor of 2-3, as are those of previous models. We find that reasonable agreement can be obtained by assuming that the rate coefficient for loss of odd nitrogen in the reaction of N with NO is smaller at temperatures that prevail in the lower Martian thermosphere than the standard value, which applies to temperatures of 200-400 K. Other aspects of this investigation are presented.
Distributions of p-values smaller than .05 in psychology: what is going on?
van Aert, Robbie C.M.; Nuijten, Michèle B.; Wicherts, Jelte M.; van Assen, Marcel A.L.M.
2016-01-01
Previous studies provided mixed findings on pecularities in p-value distributions in psychology. This paper examined 258,050 test results across 30,710 articles from eight high impact journals to investigate the existence of a peculiar prevalence of p-values just below .05 (i.e., a bump) in the psychological literature, and a potential increase thereof over time. We indeed found evidence for a bump just below .05 in the distribution of exactly reported p-values in the journals Developmental Psychology, Journal of Applied Psychology, and Journal of Personality and Social Psychology, but the bump did not increase over the years and disappeared when using recalculated p-values. We found clear and direct evidence for the QRP “incorrect rounding of p-value” (John, Loewenstein & Prelec, 2012) in all psychology journals. Finally, we also investigated monotonic excess of p-values, an effect of certain QRPs that has been neglected in previous research, and developed two measures to detect this by modeling the distributions of statistically significant p-values. Using simulations and applying the two measures to the retrieved test results, we argue that, although one of the measures suggests the use of QRPs in psychology, it is difficult to draw general conclusions concerning QRPs based on modeling of p-value distributions. PMID:27077017
Evaluation of the 1077 keV γ-ray emission probability from 68Ga decay
NASA Astrophysics Data System (ADS)
Huang, Xiao-Long; Jiang, Li-Yang; Chen, Xiong-Jun; Chen, Guo-Chang
2014-04-01
68Ga decays to the excited states of 68Zn through the electron capture decay mode. New recommended values for the emission probability of 1077 keV γ-ray given by the ENSDF and DDEP databases all use data from absolute measurements. In 2011, JIANG Li-Yang deduced a new value for 1077 keV γ-ray emission probability by measuring the 69Ga(n,2n) 68Ga reaction cross section. The new value is about 20% lower than values obtained from previous absolute measurements and evaluations. In this paper, the discrepancies among the measurements and evaluations are analyzed carefully and the new values are re-recommended. Our recommended value for the emission probability of 1077 keV γ-ray is (2.72±0.16)%.
Issue-Relevant Values and Opinions About Gay Rights: Beyond Equality and Morality.
Rhodebeck, Laurie
2018-01-01
Although many studies have examined the role of values in shaping public opinion, the number of values that inform this research is limited. This article employs the concept of issue-relevant values as a means to explore the broader range of values associated with policy issues. After discussing the concept in general terms, the article explores issue-relevant values pertinent to public opinion about gay rights. Using the policy examples of employment nondiscrimination and same-sex couple adoption, the present study identifies, measures, and assesses several values that add to the very short list previously used to explain public opinion about gay rights issues. Content from interest-group Web sites and news media coverage of the two issues aided in identifying the values. Data from an original Internet survey yield valid measures of the values. Multivariate analyses indicate that the values behave in predictable ways: they are strongly influenced by partisanship, and they strongly affect opinions about the two issues. The performance of the values is consistent with findings from previous research on the partisan basis of values and the value-based nature of opinions. The article concludes with suggestions for further empirical and theoretical work that could apply and extend the concept of issue-relevant values.
The stopping rate of negative cosmic-ray muons near sea level
NASA Technical Reports Server (NTRS)
Spannagel, G.; Fireman, E. L.
1971-01-01
A production rate of 0.065 + or - 0.003 Ar-37 atom/kg min of K-39 at 2-mwe depth below sea level was measured by sweeping argon from potassium solutions. This rate is unaffected by surrounding the solution by paraffin and is attributed to negative muon captures and the electromagnetic interaction of fast muons, and not to nucleonic cosmic ray component. The Ar-37 yield from K-39 by the stopping of negative muons in a muon beam of a synchrocyclotron was measured to be 8.5 + or - 1.7%. The stopping rate of negative cosmic ray muons at 2-mwe depth below sea level from these measurements and an estimated 17% electromagnetic production is 0.63 + or - 0.13 muon(-)/kg min. Previous measurements on the muon stopping rate vary by a factor of 5. Our value is slightly higher but is consistent with two previous high values. The sensitivity of the Ar-37 radiochemical method for the detection of muons is considerably higher than that of the previous radiochemical methods and could be used to measure the negative muon capture rates at greater depths.
Electric Monopole Transition Strengths in 62Ni
NASA Astrophysics Data System (ADS)
Evitts, L. J.; Garnsworthy, A. B.; Kibédi, T.; Moukaddam, M.; Alshahrani, B.; Eriksen, T. K.; Holt, J. D.; Hota, S. S.; Lane, G. J.; Lee, B. Q.; McCormick, B. P.; Palalani, N.; Reed, M. W.; Stroberg, S. R.; Stuchbery, A. E.
2016-09-01
Excited states in 62Ni were populated with a (p, p') reaction using the 14UD Pelletron accelerator at the Australian National University. Electric monopole transition strengths, ρ2(E0), were measured through simultaneous detection of the internal conversion electrons and γ rays emitted from the de-excitation of populated states, using the Super-e spectrometer coupled with a germanium detector. The strength of the 02+ to 01+ transition has been measured to be 77-34+23 × 10-3 and agrees with previously reported values. Upper limits have been placed on the 03+ to 01+ and 03+ to 02+ transitions. The measured ρ2(E0) value of the 22+ to 21+ transition in 62Ni has been measured for the first time and found to be one of the largest ρ2(E0) values measured to date in nuclei heavier than Ca. The low-lying states of 62Ni have previously been classified as one- and two-phonon vibrational states based on level energies. The measured electric quadrupole transition strengths are consistent with this interpretation. However as electric monopole transitions are forbidden between states which differ by one phonon number, the simple harmonic quadrupole vibrational picture is not suffcient to explain the large ρ2(E0) value for the 22+ to 21+ transition.
Predictors of Prosocial Behavior among Chinese High School Students in Hong Kong
Siu, Andrew M. H.; Shek, Daniel T. L.; Lai, Frank H. Y.
2012-01-01
This study examined the correlates and predictors of prosocial behavior among Chinese adolescents in Hong Kong. A sample of 518 high school students responded to a questionnaire containing measures of antisocial and prosocial behavior, prosocial norms, pragmatic values, moral reasoning, and empathy. Preliminary analyses showed that there were gender differences in some of the measures. While correlation analyses showed that parental education, prosocial norms, pragmatic values, moral reasoning, and empathy were related to prosocial behavior, regression analyses showed that prosocial norms, pragmatic values, and empathy dimensions (personal distress and empathy) were key predictors of it. The findings are largely consistent with theoretical predictions and previous research findings, other than the negative relationship between personal distress and prosocial behavior. The study also underscores the importance of values and norms in predicting prosocial behavior, which has been largely neglected in previous studies. PMID:22919326
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eronen, T.; Elomaa, V.; Hager, U.
2006-12-08
The {beta}-decay Q{sub EC} values of the superallowed beta emitters {sup 26}Al{sup m}, {sup 42}Sc, and {sup 46}V have been measured with a Penning trap to a relative precision of better than 8x10{sup -9}. Our result for {sup 46}V, 7052.72(31) keV, confirms a recent measurement that differed from the previously accepted reaction-based Q{sub EC} value. However, our results for {sup 26}Al{sup m} and {sup 42}Sc, 4232.83(13) keV and 6426.13(21) keV, are consistent with previous reaction-based values. By eliminating the possibility of a systematic difference between the two techniques, this result demonstrates that no significant shift in the deduced value ofmore » V{sub ud} should be anticipated.« less
Alperin, Noam; Lee, Sang H; Bagci, Ahmet M
2015-10-01
To add the hydrostatic component of the cerebrospinal fluid (CSF) pressure to magnetic resonance imaging (MRI)-derived intracranial pressure (ICP) measurements in the upright posture for derivation of pressure value in a central cranial location often used in invasive ICP measurements. Additional analyses were performed using data previously collected from 10 healthy subjects scanned in supine and sitting positions with a 0.5T vertical gap MRI scanner (GE Medical). Pulsatile blood and CSF flows to and from the brain were quantified using cine phase-contrast. Intracranial compliance and pressure were calculated using a previously described method. The vertical distance between the location of the CSF flow measurement and a central cranial location was measured manually in the mid-sagittal T1 -weighted image obtained in the upright posture. The hydrostatic pressure gradient of a CSF column with similar height was then added to the MR-ICP value. After adjustment for the hydrostatic component, the mean ICP value was reduced by 7.6 mmHg. Mean ICP referenced to the central cranial level was -3.4 ± 1.7 mmHg compared to the unadjusted value of +4.3 ± 1.8 mmHg. In the upright posture, the hydrostatic pressure component needs to be added to the MRI-derived ICP values for compatibility with invasive ICP at a central cranial location. © 2015 Wiley Periodicals, Inc.
Measurements of (60)Co in massive steel samples exposed to the Hiroshima atomic bomb explosion.
Gasparro, Joël; Hult, Mikael; Marissens, Gerd; Hoshi, Masaharu; Tanaka, Kenichi; Endo, Satoru; Laubenstein, Matthias; Dombrowski, Harald; Arnold, Dirk
2012-04-01
To study discrepancies in retrospective Hiroshima dosimetry, the specific activity of (60)Co in 16 steel samples from Hiroshima was measured using gamma-ray spectrometry in underground laboratories. There is general agreement between these new activity measurements and the specific activities derived from previously calculated dose values on the one hand and former measurements of samples gathered at distances less than 1,000 m from the center of the explosion (< 1,000 m slant range) on the other. It was found that activities at long range (> 1,300 m slant range) were mainly cosmogenically induced. Furthermore, at long range, these results are in disagreement with older measurements whose specific activity values were 10 to 100 times higher than predicted by computer model calculations in DS86 and DS02. As a consequence, the previously reported discrepancy is not confirmed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, X; Wang, Y
Purpose: Due to limited commissioning time, we previously only released our True beam non-FFF mode for prostate treatment. Clinical demand now pushes us to release the non-FFF mode for SRT/SBRT treatment. When re-planning on True beam previously treated SRT/SBRT cases on iX machine we found the patient specific QA pass rate was worse than iX’s, though the 2Gy/fx prostate Result had been as good. We hypothesize that in TPS the True beam DLG and MLC transmission values, of those measured during commissioning could not yet provide accurate SRS/SBRT dosimetry. Hence this work is to investigate how the TPS DLG andmore » transmission value affects Rapid Arc plans’ dosimetric accuracy. Methods: We increased DLG and transmission value of True beam in TPS such that their percentage differences against the measured matched those of iX’s. We re-calculated 2 SRT, 1 SBRT and 2 prostate plans, performed patient specific QA on these new plans and compared the results to the previous. Results: With DLG and transmission value set respectively 40 and 8% higher than the measured, the patient specific QA pass rate (at 3%/3mm) improved from 95.0 to 97.6% vs previous iX’s 97.8% in the case of SRT. In the case of SBRT, the pass rate improved from 75.2 to 93.9% vs previous iX’s 92.5%. In the case of prostate, the pass rate improved from 99.3 to 100%. The maximum dose difference in plans before and after adjusting DLG and transmission was approximately 1% of the prescription dose among all plans. Conclusion: The impact of adjusting DLG and transmission value on dosimetry might be the same among all Rapid Arc plans regardless hypofractionated or not. The large variation observed in patient specific QA pass rate might be due to the data analysis method in the QA software being more sensitive to hypofractionated plans.« less
American College Student Values: A Normative Study.
ERIC Educational Resources Information Center
Teglovic, Jr., Steve
The 4 objectives of this study were (1) to conduct a normative study of values held by US college students, (2) to assess a wide range of value commitments of US college students as measured by an instrument validated by previous research, (3) to study the relationship between values and other relevant variables, and (4) to lay the basis for a…
Electroencephalogram approximate entropy influenced by both age and sleep.
Lee, Gerick M H; Fattinger, Sara; Mouthon, Anne-Laure; Noirhomme, Quentin; Huber, Reto
2013-01-01
The use of information-based measures to assess changes in conscious state is an increasingly popular topic. Though recent results have seemed to justify the merits of such methods, little has been done to investigate the applicability of such measures to children. For our work, we used the approximate entropy (ApEn), a measure previously shown to correlate with changes in conscious state when applied to the electroencephalogram (EEG), and sought to confirm whether previously reported trends in adult ApEn values across wake and sleep were present in children. Besides validating the prior findings that ApEn decreases from wake to sleep (including wake, rapid eye movement (REM) sleep, and non-REM sleep) in adults, we found that previously reported ApEn decreases across vigilance states in adults were also present in children (ApEn trends for both age groups: wake > REM sleep > non-REM sleep). When comparing ApEn values between age groups, adults had significantly larger ApEn values than children during wakefulness. After the application of an 8 Hz high-pass filter to the EEG signal, ApEn values were recalculated. The number of electrodes with significant vigilance state effects dropped from all 109 electrodes with the original 1 Hz filter to 1 electrode with the 8 Hz filter. The number of electrodes with significant age effects dropped from 10 to 4. Our results support the notion that ApEn can reliably distinguish between vigilance states, with low-frequency sleep-related oscillations implicated as the driver of changes between vigilance states. We suggest that the observed differences between adult and child ApEn values during wake may reflect differences in connectivity between age groups, a factor which may be important in the use of EEG to measure consciousness.
Semantic text relatedness on Al-Qur’an translation using modified path based method
NASA Astrophysics Data System (ADS)
Irwanto, Yudi; Arif Bijaksana, Moch; Adiwijaya
2018-03-01
Abdul Baquee Muhammad [1] have built Corpus that contained AlQur’an domain, WordNet and dictionary. He has did initialisation in the development of knowledges about AlQur’an and the knowledges about relatedness between texts in AlQur’an. The Path based measurement method that proposed by Liu, Zhou and Zheng [3] has never been used in the AlQur’an domain. By using AlQur’an translation dataset in this research, the path based measurement method proposed by Liu, Zhou and Zheng [3] will be used to test this method in AlQur’an domain to obtain similarity values and to measure its correlation value. In this study the degree value is proposed to be used in modifying the path based method that proposed in previous research. Degree Value is the number of links that owned by a lcs (lowest common subsumer) node on a taxonomy. The links owned by a node on the taxonomy represent the semantic relationship that a node has in the taxonomy. By using degree value to modify the path-based method that proposed in previous research is expected that the correlation value obtained will increase. After running some experiment by using proposed method, the correlation measurement value can obtain fairly good correlation ties with 200 Word Pairs derive from Noun POS SimLex-999. The correlation value that be obtained is 93.3% which means their bonds are strong and they have very strong correlation. Whereas for the POS other than Noun POS vocabulary that owned by WordNet is incomplete therefore many pairs of words that the value of its similarity is zero so the correlation value is low.
Short, Meghan E; Goetzel, Ron Z; Young, Jared S; Kowlessar, Niranjana M; Liss-Levinson, Rivka C; Tabrizi, Maryam J; Roemer, Enid Chung; Sabatelli, Adriano A; Winick, Keith; Montes, Myrtho; Crighton, K Andrew
2010-08-01
To determine the effect of health promotion programs of Prudential Financial, Inc on biometric measures of blood lipids and glucose. Using actual biometric and self-reported measures of blood lipids and glucose values for the employees of Prudential Financial, Inc, we examined 1) the extent to which self-reported lipid and blood glucose values correlate to laboratory data, 2) whether self-reported and measured lipid values differ for physically active and sedentary employees, and 3) whether participation in a disease management program affects employees' lipid measures. We found significant differences in self-reported and measured total cholesterol and low-density lipoprotein values, although these differences and those for all lipid and blood glucose values were not clinically meaningful. Supporting previous clinical studies, high-density lipoprotein values were significantly higher for fitness center users compared with sedentary employees. Finally, disease management participants showed a significant reduction in total cholesterol and low-density lipoprotein during a 3-year period compared with nonparticipants. On average, the employees of Prudential Financial, Inc were aware of and accurately reported their lipid and blood glucose levels. Results from this study support the value of evaluating corporate health promotion programs, using measured biometric outcomes.
NASA Technical Reports Server (NTRS)
Lee, Cynthia C.; Obara, Clifford J.; Vijgen, Paul M.; Wusk, Michael S.
1991-01-01
Flight test results are reported from an experiment designed to study the detailed growth of disturbances in the laminar boundary layer. A gloved wing section incorporating closely-spaced flush-mounted streamwise-located instrumentation for measuring instability frequencies and amplitude growths as well as pressure distributions was used. The growth of Tollmien-Schlichting (T-S) and crossflow instabilities is predicted by the linear e exp n method and compared to the measured boundary-layer disturbance frequencies. The predictions showed good agreement with the measured data. The results exhibited fair agreement with previous n(T-S) and n(CF) flight correlations for several of the conditions analyzed. It is inferred from the high n(T-S) values for these data that moderately swept wings at compressible speeds can withstand higher combinations of n(T-S) and n(CF) values and still remain laminar than previously thought.
Method and apparatus for I-V data acquisition from solar cells
Cole, Steven W.
1985-01-01
A method and apparatus for logging current-voltage (I-V) characteristic d of a solar cell module (10) in two modes using a portable instrument. One mode controls the load current through a circuit (36) in 256 equal intervals while voltage is measured from open circuit to at least halfway into the knee of the curve and the other mode controls the load voltage through a circuit (34) in 256 equal intervals from the lowest voltage measurement possible (short circuit) to at least halfway into the knee of the curve, under control of a microcomputer (12). All measurements are packed by discarding each measurement that is within 0.5% of the value predicted from two previous measurements, except every ninth (9th) measurement which is retained. The remaining data is further packed into a memory block of a detachable storage medium (14) by recording the data points in sequence following a header containing data common to all points, with each point having the value of the controlled parameter recorded as the number of increments from the previous point recorded followed by the measured value. The detachable storage medium is preferably a solid state device for reliability, and is transferable to a playback terminal which unpacks the data for analysis and display.
Kondo, Takashi; Kobayashi, Daisuke; Mochizuki, Maki; Asanuma, Kouichi; Takahashi, Satoshi
2017-01-01
Background Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. However, differences in measured values between these new reagents and previously used reagents have not been well studied. In this study, we aimed to compare the values between ARCHITECT High-Sensitive Troponin I ST (newly developed reagents), ARCHITECT Troponin I ST and STACIA CLEIA cardiac troponin I (two previously developed reagent kits). Methods Gel filtration high-performance liquid chromatography was used to analyse the causes of differences in measured values. Results The measured values differed between ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cardiac troponin I reagents (r = 0.82). Cross-reactivity tests using plasma with added skeletal-muscle troponin I resulted in higher reactivity (2.17-3.03%) for the STACIA CLEIA cardiac troponin I reagents compared with that for the ARCHITECT High-Sensitive Troponin I ST reagents (less than 0.014%). In addition, analysis of three representative samples using gel filtration high-performance liquid chromatography revealed reagent-specific differences in the reactivity against each cardiac troponin I complex; this could explain the differences in values observed for some of the samples. Conclusion The newly developed ARCHITECT High-Sensitive Troponin I ST reagents were not affected by the presence of skeletal-muscle troponin I in the blood and may be useful for routine examinations.
NASA Astrophysics Data System (ADS)
Feng, X. J.; Zhang, J. T.; Lin, H.; Gillis, K. A.; Mehl, J. B.; Moldover, M. R.; Zhang, K.; Duan, Y. N.
2017-10-01
We report a new determination of the Boltzmann constant k B using a cylindrical acoustic gas thermometer. We determined the length of the copper cavity from measurements of its microwave resonance frequencies. This contrasts with our previous work (Zhang et al 2011 Int. J. Thermophys. 32 1297, Lin et al 2013 Metrologia 50 417, Feng et al 2015 Metrologia 52 S343) that determined the length of a different cavity using two-color optical interferometry. In this new study, the half-widths of the acoustic resonances are closer to their theoretical values than in our previous work. Despite significant changes in resonator design and the way in which the cylinder length is determined, the value of k B is substantially unchanged. We combined this result with our four previous results to calculate a global weighted mean of our k B determinations. The calculation follows CODATA’s method (Mohr and Taylor 2000 Rev. Mod. Phys. 72 351) for obtaining the weighted mean value of k B that accounts for the correlations among the measured quantities in this work and in our four previous determinations of k B. The weighted mean {{\\boldsymbol{\\hat{k}}}{B}} is 1.380 6484(28) × 10-23 J K-1 with the relative standard uncertainty of 2.0 × 10-6. The corresponding value of the universal gas constant is 8.314 459(17) J K-1 mol-1 with the relative standard uncertainty of 2.0 × 10-6.
Fine-particle pH for Beijing winter haze as inferred from different thermodynamic equilibrium models
NASA Astrophysics Data System (ADS)
Song, Shaojie; Gao, Meng; Xu, Weiqi; Shao, Jingyuan; Shi, Guoliang; Wang, Shuxiao; Wang, Yuxuan; Sun, Yele; McElroy, Michael B.
2018-05-01
pH is an important property of aerosol particles but is difficult to measure directly. Several studies have estimated the pH values for fine particles in northern China winter haze using thermodynamic models (i.e., E-AIM and ISORROPIA) and ambient measurements. The reported pH values differ widely, ranging from close to 0 (highly acidic) to as high as 7 (neutral). In order to understand the reason for this discrepancy, we calculated pH values using these models with different assumptions with regard to model inputs and particle phase states. We find that the large discrepancy is due primarily to differences in the model assumptions adopted in previous studies. Calculations using only aerosol-phase composition as inputs (i.e., reverse mode) are sensitive to the measurement errors of ionic species, and inferred pH values exhibit a bimodal distribution, with peaks between -2 and 2 and between 7 and 10, depending on whether anions or cations are in excess. Calculations using total (gas plus aerosol phase) measurements as inputs (i.e., forward mode) are affected much less by these measurement errors. In future studies, the reverse mode should be avoided whereas the forward mode should be used. Forward-mode calculations in this and previous studies collectively indicate a moderately acidic condition (pH from about 4 to about 5) for fine particles in northern China winter haze, indicating further that ammonia plays an important role in determining this property. The assumed particle phase state, either stable (solid plus liquid) or metastable (only liquid), does not significantly impact pH predictions. The unrealistic pH values of about 7 in a few previous studies (using the standard ISORROPIA model and stable state assumption) resulted from coding errors in the model, which have been identified and fixed in this study.
Initial study of deep inelastic scattering with ZEUS at HERA
NASA Astrophysics Data System (ADS)
Derrick, M.; Krakauer, D.; Magill, S.; Musgrave, B.; Repond, J.; Repond, S.; Stanek, R.; Talaga, R. L.; Thron, J.; Arzarello, F.; Ayad, R.; Barbagli, G.; Bari, G.; Basile, M.; Bellagamba, L.; Boscherini, D.; Bruni, A.; Bruni, G.; Bruni, P.; Cara Romeo, G.; Castellini, G.; Chiarini, M.; Cifarelli, L.; Cindolo, F.; Ciralli, F.; Contin, A.; D'Auria, S.; del Papa, C.; Frasconi, F.; Giusti, P.; Iacobucci, G.; Laurenti, G.; Levi, G.; Lin, Q.; Lisowski, B.; Maccarrone, G.; Margotti, A.; Massam, T.; Nania, R.; Nemoz, C.; Palmonari, F.; Sartorelli, G.; Timellini, R.; Zamora Garcia, Y.; Zichichi, A.; Bargende, A.; Crittenden, J.; Dabbous, H.; Desch, K.; Diekmann, B.; Doeker, T.; Geerts, M.; Geitz, G.; Gutjahr, B.; Hartmann, H.; Hartmann, J.; Haun, D.; Heinloth, K.; Hilger, E.; Jakob, H.-P.; Kramarczyk, S.; Kückes, M.; Mass, A.; Mengel, S.; Mollen, J.; Monaldi, D.; Müsch, H.; Paul, E.; Schattevoy, R.; Schneider, J.-L.; Wedemeyer, R.; Cassidy, A.; Cussans, D. G.; Dyce, N.; Fawcett, H. F.; Foster, B.; Gilmore, R.; Heath, G. P.; Lancaster, M.; Llewellyn, T. J.; Malos, J.; Morgado, C. J. S.; Tapper, R. J.; Wilson, S. S.; Rau, R. R.; Barillari, T.; Schioppa, M.; Susinno, G.; Bernstein, A.; Caldwell, A.; Gialas, I.; Parsons, J. A.; Ritz, S.; Sciulli, F.; Straub, P. B.; Wai, L.; Yang, S.; Burkot, W.; Eskreys, A.; Piotrzkowski, K.; Zachara, M.; Zawiejski, L.; Borzemski, P.; Jeleń, K.; Kisielewska, D.; Kowalski, T.; Rulikowska-Zerȩbska, E.; Suszycki, L.; Zajc, J.; Kȩdzierski, T.; Kotański, A.; Przybycień, M.; Bauerdick, L. A. T.; Behrens, U.; Bienlein, J. K.; Coldewey, C.; Dannemann, A.; Dierks, K.; Dorth, W.; Drews, G.; Erhard, P.; Flasiński, M.; Fleck, I.; Fürtjes, A.; Gläser, R.; Göttlicher, P.; Hass, T.; Hagge, L.; Hain, W.; Hasell, D.; Hultschig, H.; Jahnen, G.; Joos, P.; Kasemann, M.; Klanner, R.; Koch, W.; Kötz, U.; Kowalski, H.; Labs, J.; Ladage, A.; Löhr, B.; Lüke, D.; Mainusch, J.; Manczak, O.; Momayezi, M.; Ng, J. S. T.; Nicel, S.; Notz, D.; Park, I. H.; Pösnecker, K.-U.; Rohde, M.; Ros, E.; Schneekloth, S.; Schroeder, J.; Schulz, W.; Selonke, F.; Stiliaris, E.; Tscheslog, E.; Tsurugai, T.; Turkot, F.; Vogel, W.; Woeniger, T.; Wolf, G.; Youngman, C.; Grabosch, H. J.; Leich, A.; Meyer, A.; Rethfeldt, C.; Schlensthdt, S.; Casalbuoni, R.; de Curtis, S.; Dominici, D.; Francescato, A.; Nuti, M.; Pelfer, P.; Anzivino, G.; Casaccia, R.; de Pasquale, S.; Qian, S.; Votano, L.; Bamberger, A.; Freidhof, A.; Poser, T.; Söldner-Rembold, S.; Theisen, G.; Trefzger, T.; Brook, N. H.; Bussey, P. J.; Doyle, A. T.; Forbes, J. R.; Jamieson, V. A.; Raine, C.; Saxon, D. H.; Brückmann, H.; Gloth, G.; Holm, U.; Kammerdocher, H.; Krebs, B.; Neumann, T.; Wick, K.; Hofmann, A.; Kröger, W.; Krüger, J.; Lohrmann, E.; Milewski, J.; Nakahata, M.; Pavel, N.; Poelz, G.; Salomon, R.; Seidman, A.; Schott, W.; Wiik, B. H.; Zetsche, F.; Bacon, T. C.; Butterworth, I.; Markou, C.; McQuillan, D.; Miller, D. B.; Mobayyen, M. M.; Prinias, A.; Vorvolakos, A.; Bienz, T.; Kreutzmann, H.; Mallik, U.; McCliment, E.; Roco, M.; Wang, M. Z.; Cloth, P.; Filges, D.; Chen, L.; Imlay, R.; Kartik, S.; Kim, H.-J.; McNeil, R. R.; Metcalf, W.; Barreiro, F.; Cases, G.; Hervás, L.; Labarga, L.; del Peso, J.; Roldán, J.; Terrón, J.; de Trocóniz, J. F.; Ikraiam, F.; Mayer, J. K.; Smith, G. R.; Corriveau, F.; Gilkinson, D. J.; Hanna, D. S.; Hung, L. W.; Mitchell, J. W.; Patel, P. M.; Sinclair, L. E.; Stairs, D. G.; Ullmann, R.; Bashindzhagyan, G. L.; Ermolov, P. F.; Golubkov, Y. A.; Kuzmin, V. A.; Kuznetsov, E. N.; Savin, A. A.; Voronin, A. G.; Zotov, N. P.; Bentvelsen, S.; Dake, A.; Engelen, J.; de Jong, P.; de Jong, S.; de Kamps, M.; Kooijman, P.; Kruse, A.; van der Lugt, H.; O'dell, V.; Straver, J.; Tenner, A.; Tiecke, H.; Uijterwaal, H.; Vermeulen, J.; Wiggers, L.; de Wolf, E.; van Woudenberg, R.; Yoshida, R.; Bylsma, B.; Durkin, L. S.; Li, C.; Ling, T. Y.; McLean, K. W.; Murray, W. N.; Park, S. K.; Romanowski, T. A.; Seidlein, R.; Blair, G. A.; Butterworth, J. M.; Byrne, A.; Cashmore, R. J.; Cooper-Sarkar, A. M.; Devenish, R. C. E.; Gingrich, D. M.; Hallam-Baker, P. M.; Harnew, N.; Khatri, T.; Long, K. R.; Luffman, P.; McArthur, I.; Morawitz, P.; Nash, J.; Smith, S. J. P.; Roocroft, N. C.; Wilson, F. F.; Abbiendi, G.; Brugnera, R.; Carlin, R.; dal Corso, F.; de Giorgi, M.; Dosselli, U.; Gasparini, F.; Limentani, S.; Morandin, M.; Posocco, M.; Stanco, L.; Stroili, R.; Voci, C.; Field, G.; Lim, J. N.; Oh, B. Y.; Whitmore, J.; Contino, U.; D'Agostini, G.; Guida, M.; Iori, M.; Mari, S. M.; Marini, G.; Mattioli, M.; Nigro, A.; Hart, J. C.; McCubbin, N. A.; Shah, T. P.; Short, T. L.; Barberis, E.; Cartiglia, N.; Heusch, C.; Hubbard, B.; Leslie, J.; O'Shaughnessy, K.; Sadrozinski, H. F.; Seiden, A.; Badura, E.; Biltzinger, J.; Chaves, H.; Rost, M.; Seifert, R. J.; Walenta, A. H.; Weihs, W.; Zech, G.; Dagan, S.; Levy, A.; Zer-Zion, D.; Hasegawa, T.; Hazumi, M.; Ishii, T.; Kasai, S.; Kuze, M.; Nagasawa, Y.; Nakao, M.; Okuno, H.; Tokushuku, K.; Watanabe, T.; Yamada, S.; Chiba, M.; Hamatsu, R.; Hirose, T.; Kitamura, S.; Nagayama, S.; Nakamitsu, Y.; Arneodo, M.; Costa, M.; Ferrero, M. I.; Lamberti, L.; Maselli, S.; Peroni, C.; Solano, A.; Staiano, A.; Dardo, M.; Bailey, D. C.; Bandyopadhyay, D.; Benard, F.; Bhadra, S.; Brkic, M.; Burow, B. D.; Chlebana, F. S.; Crombie, M. B.; Hartner, G. F.; Levman, G. M.; Martin, J. F.; Orr, R. S.; Prentice, J. D.; Sampson, C. R.; Stairs, G. G.; Teuscher, R. J.; Yoon, T.-S.; Bullock, F. W.; Catterall, C. D.; Giddings, J. C.; Jones, T. W.; Khan, A. M.; Lane, J. B.; Makkar, P. L.; Shaw, D.; Shulman, J.; Blankenship, K.; Gibaut, D. B.; Kochocki, J.; Lu, B.; Mo, L. W.; Charchula, K.; Ciborowski, J.; Gajewski, J.; Grzelak, G.; Kasprzak, M.; Krzyżanowski, M.; Muchorowski, K.; Nowak, R. J.; Pawlak, J. M.; Stojda, K.; Stopczyński, A.; Szwed, R.; Tymieniecka, T.; Walczak, R.; Wróblewski, A. K.; Zakrzewski, J. A.; Zarnecki, A. F.; Adamus, M.; Abramowicz, H.; Eisenberg, Y.; Glasman, C.; Karshon, U.; Montag, A.; Revel, D.; Shapira, A.; Ali, I.; Behrens, B.; Camerini, U.; Dasu, S.; Fordham, C.; Foudas, C.; Goussiou, A.; Lomperski, M.; Loveless, R. J.; Nylander, P.; Ptacek, M.; Reeder, D. D.; Smith, W. H.; Silverstein, S.; Frisken, W. R.; Furutani, K. M.; Iga, Y.
1993-04-01
Results are presented on neutral current, deep inelastic scattering measured in collisions of 26.7 GeV electrons and 820 GeV protons. The events typically populate a range in Q2 from 10 to 100 GeV2. The values of x extend down to x ~ 10-4 which is two orders of magnitude lower than previously measured at such Q2 values in fixed target experiments. The measured cross sections are in accord with the extrapolations of current parametrisations of parton distributions.
Administrative database code accuracy did not vary notably with changes in disease prevalence.
van Walraven, Carl; English, Shane; Austin, Peter C
2016-11-01
Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.
The Mexican American Cultural Values scales for Adolescents and Adults
Knight, George P.; Gonzales, Nancy A.; Saenz, Delia S.; Bonds, Darya D.; Germán, Miguelina; Deardorff, Julianna; Roosa, Mark W.; Updegraff, Kimberly A.
2009-01-01
This research evaluates the properties of a measure of culturally linked values of Mexican Americans in early adolescence and adulthood. The items measure were derived from qualitative data provided by focus groups in which Mexican Americans’ (adolescents, mothers and fathers) perceptions of key values were discussed. The focus groups and a preliminary item refinement resulted in the fifty-item Mexican American Cultural Values Scales (identical for adolescents and adults) that includes nine value subscales. Analyses of data from two large previously published studies sampling Mexican American adolescents, mothers, and fathers provided evidence of the expected two correlated higher order factor structures, reliability, and construct validity of the subscales of the Mexican American Cultural Values Scales as indicators of values that are frequently associated with Mexican/Mexican American culture. The utility of this measure for use in longitudinal research, and in resolving some important theoretical questions regarding dual cultural adaptation, are discussed. PMID:20644653
The Logic of Quantum Measurements
NASA Astrophysics Data System (ADS)
Vanni, Leonardo; Laura, Roberto
2013-07-01
We apply our previously developed formalism of contexts of histories, suitable to deal with quantum properties at different times, to the measurement process. We explore the logical implications which are allowed by the quantum theory, about the realization of properties of the microscopic measured system, before and after the measurement process with a given pointer value.
On the Value-Dependence of Value-Driven Attentional Capture
Anderson, Brian A.; Halpern, Madeline
2017-01-01
Findings from an increasingly large number of studies have been used to argue that attentional capture can be dependent on the learned value of a stimulus, or value-driven. However, under certain circumstances attention can be biased to select stimuli that previously served as targets, independent of reward history. Value-driven attentional capture, as studied using the training phase-test phase design introduced by Anderson and colleagues, is widely presumed to reflect the combined influence of learned value and selection history. However, the degree to which attentional capture is at all dependent on value learning in this paradigm has recently been questioned. Support for value-dependence can be provided through one of two means: (1) greater attentional capture by prior targets following rewarded training than following unrewarded training, and (2) greater attentional capture by prior targets previously associated with high compared to low value. Using a variant of the original value-driven attentional capture paradigm, Sha and Jiang (2016) failed to find evidence of either, and raised criticisms regarding the adequacy of evidence provided by prior studies using this particular paradigm. To address this disparity, here we provided a stringent test of the value-dependence hypothesis using the traditional value-driven attentional capture paradigm. With a sufficiently large sample size, value-dependence was observed based on both criteria, with no evidence of attentional capture without rewards during training. Our findings support the validity of the traditional value-driven attentional capture paradigm in measuring what its name purports to measure. PMID:28176215
ERIC Educational Resources Information Center
LoPresto, Michael C.
2013-01-01
In a previous article in this journal, we reported on a laboratory activity in which students used a derivation from the Stefan-Boltzmann law to calculate planetary temperatures and compare them to measured values from various (mostly online) sources. The calculated temperatures matched observed values very well with the exceptions of Venus and…
Lorne, Emmanuel; Diouf, Momar; de Wilde, Robert B P; Fischer, Marc-Olivier
2018-02-01
The Bland-Altman (BA) and percentage error (PE) methods have been previously described to assess the agreement between 2 methods of medical or laboratory measurements. This type of approach raises several problems: the BA methodology constitutes a subjective approach to interchangeability, whereas the PE approach does not take into account the distribution of values over a range. We describe a new methodology that defines an interchangeability rate between 2 methods of measurement and cutoff values that determine the range of interchangeable values. We used a simulated data and a previously published data set to demonstrate the concept of the method. The interchangeability rate of 5 different cardiac output (CO) pulse contour techniques (Wesseling method, LiDCO, PiCCO, Hemac method, and Modelflow) was calculated, in comparison with the reference pulmonary artery thermodilution CO using our new method. In our example, Modelflow with a good interchangeability rate of 93% and a cutoff value of 4.8 L min, was found to be interchangeable with the thermodilution method for >95% of measurements. Modelflow had a higher interchangeability rate compared to Hemac (93% vs 86%; P = .022) or other monitors (Wesseling cZ = 76%, LiDCO = 73%, and PiCCO = 62%; P < .0001). Simulated data and reanalysis of a data set comparing 5 CO monitors against thermodilution CO showed that, depending on the repeatability of the reference method, the interchangeability rate combined with a cutoff value could be used to define the range of values over which interchangeability remains acceptable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.; Coleman, C.; Diprete, D.
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 41.3 mg/L while the sub-surface sample was 43.5 mg/L. The Tank 43H samples contained total uranium concentrations of 28.5 mg/L in the surface sample and 28.1 mg/L in the sub-surface sample. The U-235 percentage ranged from 0.62% to 0.63% for the Tank 38H samples and Tank 43H samples. The total uranium and percent U-235 results in the table appear slightly lower than recent Tank 38H and Tank 43H uranium measurements. The plutonium results in the tablemore » show a large difference between the surface and sub-surface sample concentrations for Tank 38H. The Tank 43H plutonium results closely match the range of values measured on previous samples. The Cs-137 results for the Tank 38H surface and sub-surface samples show similar concentrations slightly higher than the concentrations measured in recent samples. The Cs-137 results for the two Tank 43H samples also show similar concentrations within the range of values measured on previous samples. The four samples show silicon concentrations somewhat lower than the previous samples with values ranging from 124 to 168 mg/L.« less
Ballistics-Electron-Microscopy and Spectroscopy of Metal/GaN Interfaces
NASA Technical Reports Server (NTRS)
Bell, L. D.; Smith, R. P.; McDermott, B. T.; Gertner, E. R.; Pittman, R.; Pierson, R. L.; Sullivan, G. J.
1997-01-01
BEEM spectroscopy and imaging have been applied to the Au/GaN interface. In contrast to previous BEEM measurements, spectra yield a Schottky barrier height of 1.04eV that agrees well with the highest values measured by conventional methods.
Neuropsychological function and past exposure to metallic mercury in female dental workers
Sletvold, Helge; Svendsen, Kristin; Aas, Oddfrid; Syversen, Tore; Hilt, Bjørn
2012-01-01
The aim of this study was to see if dental personnel with previous exposure to metallic mercury have later developed disturbances in cognitive function. Ninety-one female participants who had been selected from a previous health survey of dental personnel were investigated neuropsychologically within the following domains: motor function, short-term memory, working memory, executive function, mental flexibility, and visual and verbal long-term memory. The scores were mainly within normal ranges. Relationships between an exposure score, the duration of employment before 1990, and previously measured mercury in urine as independent variables and the neuropsychological findings as dependent variables, were analyzed by multiple linear regression controlling for age, general ability, length of education, alcohol consumption, and previous head injuries. The only relationship that was statistically significant in the hypothesized direction was between the previously measured urine mercury values and visual long-term memory, where the urine values explained 30% of the variability. As the study had a low statistical power and also some other methodological limitations, the results have to be interpreted with caution. Even so, we think it is right to conclude that neuropsychological findings indicative of subsequent cognitive injuries are difficult to find in groups of otherwise healthy dental personnel with previous occupational exposure to mercury. PMID:22092046
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farmer, J.D.; Ott, E.; Yorke, J.A.
Dimension is perhaps the most basic property of an attractor. In this paper we discuss a variety of different definitions of dimension, compute their values for a typical example, and review previous work on the dimension of chaotic attractors. The relevant definitions of dimension are of two general types, those that depend only on metric properties, and those that depend on probabilistic properties (that is, they depend on the frequency with which a typical trajectory visits different regions of the attractor). Both our example and the previous work that we review support the conclusion that all of the probabilistic dimensionsmore » take on the same value, which we call the dimension of the natural measure, and all of the metric dimensions take on a common value, which we call the fractal dimension. Furthermore, the dimension of the natural measure is typically equal to the Lyapunov dimension, which is defined in terms of Lyapunov numbers, and thus is usually far easier to calculate than any other definition. Because it is computable and more physically relevant, we feel that the dimension of the natural measure is more important than the fractal dimension.« less
ERIC Educational Resources Information Center
Spencer, Bryden
2016-01-01
Value-added models are a class of growth models used in education to assign responsibility for student growth to teachers or schools. For value-added models to be used fairly, sufficient statistical precision is necessary for accurate teacher classification. Previous research indicated precision below practical limits. An alternative approach has…
ERIC Educational Resources Information Center
Chow, Angela; Eccles, Jacquelynne S.; Salmela-Aro, Katariina
2012-01-01
Two independent studies were conducted to extend previous research by examining the associations between task value priority patterns across school subjects and aspirations toward the physical and information technology- (IT-) related sciences. Study 1 measured task values of a sample of 10th graders in the United States (N = 249) across (a)…
Precise Measurements of the Masses of Cs, Rb and Na A New Route to the Fine Structure Constant
NASA Astrophysics Data System (ADS)
Rainville, Simon; Bradley, Michael P.; Porto, James V.; Thompson, James K.; Pritchard, David E.
2001-01-01
We report new values for the atomic masses of the alkali 133Cs, 87Rb, 85Rb, and 23Na with uncertainties ≤ 0.2 ppb. These results, obtained using Penning trap single ion mass spectrometry, are typically two orders of magnitude more accurate than previously measured values. Combined with values of h/m atom from atom interferometry measurements and accurate wavelength measurements for different atoms, these values will lead to new ppb-level determinations of the molar Planck constant N A h and the fine structure constant α. This route to α is based on simple physics. It can potentially achieve the several ppb level of accuracy needed to test the QED determination of α extracted from measurements of the electron g factor. We also demonstrate an electronic cooling technique that cools our detector and ion below the 4 K ambient temperature. This technique improves by about a factor of three our ability to measure the ion's axial motion.
Thermodynamic characterization of tandem mismatches found in naturally occurring RNA
Christiansen, Martha E.; Znosko, Brent M.
2009-01-01
Although all sequence symmetric tandem mismatches and some sequence asymmetric tandem mismatches have been thermodynamically characterized and a model has been proposed to predict the stability of previously unmeasured sequence asymmetric tandem mismatches [Christiansen,M.E. and Znosko,B.M. (2008) Biochemistry, 47, 4329–4336], experimental thermodynamic data for frequently occurring tandem mismatches is lacking. Since experimental data is preferred over a predictive model, the thermodynamic parameters for 25 frequently occurring tandem mismatches were determined. These new experimental values, on average, are 1.0 kcal/mol different from the values predicted for these mismatches using the previous model. The data for the sequence asymmetric tandem mismatches reported here were then combined with the data for 72 sequence asymmetric tandem mismatches that were published previously, and the parameters used to predict the thermodynamics of previously unmeasured sequence asymmetric tandem mismatches were updated. The average absolute difference between the measured values and the values predicted using these updated parameters is 0.5 kcal/mol. This updated model improves the prediction for tandem mismatches that were predicted rather poorly by the previous model. This new experimental data and updated predictive model allow for more accurate calculations of the free energy of RNA duplexes containing tandem mismatches, and, furthermore, should allow for improved prediction of secondary structure from sequence. PMID:19509311
On the value-dependence of value-driven attentional capture.
Anderson, Brian A; Halpern, Madeline
2017-05-01
Findings from an increasingly large number of studies have been used to argue that attentional capture can be dependent on the learned value of a stimulus, or value-driven. However, under certain circumstances attention can be biased to select stimuli that previously served as targets, independent of reward history. Value-driven attentional capture, as studied using the training phase-test phase design introduced by Anderson and colleagues, is widely presumed to reflect the combined influence of learned value and selection history. However, the degree to which attentional capture is at all dependent on value learning in this paradigm has recently been questioned. Support for value-dependence can be provided through one of two means: (1) greater attentional capture by prior targets following rewarded training than following unrewarded training, and (2) greater attentional capture by prior targets previously associated with high compared to low value. Using a variant of the original value-driven attentional capture paradigm, Sha and Jiang (Attention, Perception, and Psychophysics, 78, 403-414, 2016) failed to find evidence of either, and raised criticisms regarding the adequacy of evidence provided by prior studies using this particular paradigm. To address this disparity, here we provided a stringent test of the value-dependence hypothesis using the traditional value-driven attentional capture paradigm. With a sufficiently large sample size, value-dependence was observed based on both criteria, with no evidence of attentional capture without rewards during training. Our findings support the validity of the traditional value-driven attentional capture paradigm in measuring what its name purports to measure.
Independent measurement of the Hoyle state β feeding from B 12 using Gammasphere
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munch, M.; Alcorta, M.; Fynbo, H. O. U.
2016-06-01
Using an array of high-purity Compton-suppressed germanium detectors, we performed an independent measurement of the beta-decay branching ratio from B-12 to the second-excited state, also known as the Hoyle state, in C-12. Our result is 0.64(11)%, which is a factor similar to 2 smaller than the previously established literature value, but is in agreement with another recent measurement. This could indicate that the Hoyle state is more clustered than previously believed. The angular correlation of the Hoyle state. cascade has also been measured for the first time. It is consistent with theoretical predictions.
Accurate oscillator strengths for interstellar ultraviolet lines of Cl I
NASA Technical Reports Server (NTRS)
Schectman, R. M.; Federman, S. R.; Beideck, D. J.; Ellis, D. J.
1993-01-01
Analyses on the abundance of interstellar chlorine rely on accurate oscillator strengths for ultraviolet transitions. Beam-foil spectroscopy was used to obtain f-values for the astrophysically important lines of Cl I at 1088, 1097, and 1347 A. In addition, the line at 1363 A was studied. Our f-values for 1088, 1097 A represent the first laboratory measurements for these lines; the values are f(1088)=0.081 +/- 0.007 (1 sigma) and f(1097) = 0.0088 +/- 0.0013 (1 sigma). These results resolve the issue regarding the relative strengths for 1088, 1097 A in favor of those suggested by astronomical measurements. For the other lines, our results of f(1347) = 0.153 +/- 0.011 (1 sigma) and f(1363) = 0.055 +/- 0.004 (1 sigma) are the most precisely measured values available. The f-values are somewhat greater than previous experimental and theoretical determinations.
A measurement of the proton structure function F2( x, Q2) at low x and low Q2 at HERA
NASA Astrophysics Data System (ADS)
Adloff, C.; Aid, S.; Anderson, M.; Andreev, V.; Andrieu, B.; Arkadov, V.; Arndt, C.; Ayyaz, I.; Babaev, A.; Bähr, J.; Bán, J.; Ban, Y.; Baranov, P.; Barrelet, E.; Barschke, R.; Bartel, W.; Bassler, U.; Beck, H. P.; Beck, M.; Behrend, H.-J.; Belousov, A.; Berger, Ch.; Bernardi, G.; Bertrand-Coremans, G.; Beyer, R.; Biddulph, P.; Bispham, P.; Bizot, J. C.; Borras, K.; Botterweck, F.; Boudry, V.; Bourov, S.; Braemer, A.; Braunschweig, W.; Brisson, V.; Brückner, W.; Bruel, P.; Bruncko, D.; Brune, C.; Buchholz, R.; Büngener, L.; Bürger, J.; Büsser, F. W.; Buniatian, A.; Burke, S.; Burton, M. J.; Buschhorn, G.; Calvet, D.; Campbell, A. J.; Carli, T.; Charlet, M.; Clarke, D.; Clerbaux, B.; Cocks, S.; Contreras, J. G.; Cormack, C.; Coughlan, J. A.; Courau, A.; Cousinou, M.-C.; Cox, B. E.; Cozzika, G.; Cussans, D. G.; Cvach, J.; Dagoret, S.; Dainton, J. B.; Dau, W. D.; Daum, K.; David, M.; Davis, C. L.; De Roeck, A.; De Wolf, E. A.; Delcourt, B.; Dirkmann, M.; Dixon, P.; Dlugosz, W.; Dollfus, C.; Donovan, K. T.; Dowell, J. D.; Dreis, H. B.; Droutskoi, A.; Ebert, J.; Ebert, T. R.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Eisenhandler, E.; Elsen, E.; Erdmann, M.; Fahr, A. B.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Ferrarotto, F.; Flamm, K.; Fleischer, M.; Flieser, M.; Flügge, G.; Fomenko, A.; Formánek, J.; Foster, J. M.; Franke, G.; Gabathuler, E.; Gabathuler, K.; Gaede, F.; Garvey, J.; Gayler, J.; Gebauer, M.; Genzel, H.; Gerhards, R.; Glazov, A.; Goerlich, L.; Gogitidze, N.; Goldberg, M.; Goldner, D.; Golec-Biernat, K.; Gonzalez-Pineiro, B.; Gorelov, I.; Grab, C.; Grässler, H.; Greenshaw, T.; Griffiths, R. K.; Grindhammer, G.; Gruber, A.; Gruber, C.; Hadig, T.; Haidt, D.; Hajduk, L.; Haller, T.; Hampel, M.; Haynes, W. J.; Heinemann, B.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Herynek, I.; Hess, M. F.; Hewitt, K.; Hiller, K. H.; Hilton, C. D.; Hladký, J.; Höppner, M.; Hoffmann, D.; Holtom, T.; Horisberger, R.; Hudgson, V. L.; Hütte, M.; Ibbotson, M.; İşsever, Ç.; Itterbeck, H.; Jacholkowska, A.; Jacobsson, C.; Jacquet, M.; Jaffre, M.; Janoth, J.; Jansen, D. M.; Jönsson, L.; Johnson, D. P.; Jung, H.; Kalmus, P. I. P.; Kander, M.; Kant, D.; Kathage, U.; Katzy, J.; Kaufmann, H. H.; Kaufmann, O.; Kausch, M.; Kazarian, S.; Kenyon, I. R.; Kermiche, S.; Keuker, C.; Kiesling, C.; Klein, M.; Kleinwort, C.; Knies, G.; Köhler, T.; Köhne, J. H.; Kolanoski, H.; Kolya, S. D.; Korbel, V.; Kostka, P.; Kotelnikov, S. K.; Krämerkämper, T.; Krasny, M. W.; Krehbiel, H.; Krücker, D.; Küpper, A.; Küster, H.; Kuhlen, M.; Kurča, T.; Kurzhöfer, J.; Laforge, B.; Landon, M. P. J.; Lange, W.; Langenegger, U.; Lebedev, A.; Lehner, F.; Lemaitre, V.; Levonian, S.; Lindstroem, M.; Linsel, F.; Lipinski, J.; List, B.; Lobo, G.; Lomas, J. W.; Lopez, G. C.; Lubimov, V.; Lüke, D.; Lytkin, L.; Magnussen, N.; Mahlke-Krüger, H.; Malinovski, E.; Maraček, R.; Marage, P.; Marks, J.; Marshall, R.; Martens, J.; Martin, G.; Martin, R.; Martyn, H.-U.; Martyniak, J.; Mavroidis, T.; Maxfield, S. J.; McMahon, S. J.; Mehta, A.; Meier, K.; Merkel, P.; Metlica, F.; Meyer, A.; Meyer, A.; Meyer, H.; Meyer, J.; Meyer, P.-O.; Migliori, A.; Mikocki, S.; Milstead, D.; Moeck, J.; Moreau, F.; Morris, J. V.; Mroczko, E.; Müller, D.; Walter, T.; Müller, K.; Murín, P.; Nagovizin, V.; Nahnhauer, R.; Naroska, B.; Naumann, Th.; Négri, I.; Newman, P. R.; Newton, D.; Nguyen, H. K.; Nicholls, T. C.; Niebergall, F.; Niebuhr, C.; Niedzballa, Ch.; Niggli, H.; Nowak, G.; Nunnemann, T.; Nyberg-Werther, M.; Oberlack, H.; Olsson, J. E.; Ozerov, D.; Palmen, P.; Panaro, E.; Panitch, A.; Pascaud, C.; Passaggio, S.; Patel, G. D.; Pawletta, H.; Peppel, E.; Perez, E.; Phillips, J. P.; Pieuchot, A.; Pitzl, D.; Pöschl, R.; Pope, G.; Povh, B.; Prell, S.; Rabbertz, K.; Rädel, G.; Reimer, P.; Rick, H.; Riess, S.; Rizvi, E.; Robmann, P.; Roosen, R.; Rosenbauer, K.; Rostovtsev, A.; Rouse, F.; Royon, C.; Rüter, K.; Rusakov, S.; Rybicki, K.; Sankey, D. P. C.; Schacht, P.; Schiek, S.; Schleif, S.; Schleper, P.; von Schlippe, W.; Schmidt, D.; Schmidt, G.; Schoeffel, L.; Schöning, A.; Schröder, V.; Schuhmann, E.; Schwab, B.; Sefkow, F.; Semenov, A.; Shekelyan, V.; Sheviakov, I.; Shtarkov, L. N.; Siegmon, G.; Siewert, U.; Sirois, Y.; Skillicorn, I. O.; Sloan, T.; Smirnov, P.; Smith, M.; Solochenko, V.; Soloviev, Y.; Specka, A.; Spiekermann, J.; Spielman, S.; Spitzer, H.; Squinabol, F.; Steffen, P.; Steinberg, R.; Steinhart, J.; Stella, B.; Stellberger, A.; Stier, J.; Stiewe, J.; Stöβlein, U.; Stolze, K.; Straumann, U.; Struczinski, W.; Sutton, J. P.; Tapprogge, S.; Taševský, M.; Tchernyshov, V.; Tchetchelnitski, S.; Theissen, J.; Thompson, G.; Thompson, P. D.; Tobien, N.; Todenhagen, R.; Truöl, P.; Tsipolitis, G.; Turnau, J.; Tzamariudaki, E.; Uelkes, P.; Usik, A.; Valkár, S.; Valkárová, A.; Valĺee, C.; Van Esch, P.; Van Mechelen, P.; Vandenplas, D.; Vazdik, Y.; Verrecchia, P.; Villet, G.; Wacker, K.; Wagener, A.; Wagener, M.; Wallny, R.; Waugh, B.; Weber, G.; Weber, M.; Wegener, D.; Wegner, A.; Wengler, T.; Werner, M.; West, L. R.; Wiesand, S.; Wilksen, T.; Willard, S.; Winde, M.; Winter, G.-G.; Wittek, C.; Wobisch, M.; Wollatz, H.; Wünsch, E.; Žáček, J.; Zarbock, D.; Zhang, Z.; Zhokin, A.; Zini, P.; Zomer, F.; Zsembery, J.; zurNedden, M.; H1 Collaboration
1997-02-01
The results of a measurement of the proton structure function F2( x, Q2) and the virtual photon-proton cross section are reported for momentum transfers squared Q2 between 0.35 GeV 2 and 3.5 GeV 2 and for Bjorken- x values down to 6 × 10 -6 using data collected by the HERA experiment H1 in 1995. The data represent an increase in kinematic reach to lower x and Q2 values of about a factor of 5 compared to previous H1 measurements. Including measurements from fixed target experiments the rise of F2 with decreasing x is found to be less steep for the lowest Q2 values measured. Phenomenological models at low Q2 are compared with the data.
Preiss, David; Thomas, Laine E; Wojdyla, Daniel M; Haffner, Steven M; Gill, Jason M R; Yates, Thomas; Davies, Melanie J; Holman, Rury R; McMurray, John J; Califf, Robert M; Kraus, William E
2015-08-14
While bidirectional relationships exist between body weight and physical activity, direction of causality remains uncertain and previous studies have been limited by self-reported activity or weight and small sample size. We investigated the prospective relationships between weight and physical activity. Observational analysis of data from the Nateglinide And Valsartan in Impaired Glucose Tolerance Outcomes Research (NAVIGATOR) study, a double-blinded randomised clinical trial of nateglinide and valsartan, respectively. Multinational study of 9306 participants. Participants with biochemically confirmed impaired glucose tolerance had annual measurements of both weight and step count using research grade pedometers, worn for 7 days consecutively. Along with randomisation to valsartan or placebo plus nateglinide or placebo, participants took part in a lifestyle modification programme. Longitudinal regression using weight as response value and physical activity as predictor value was conducted, adjusted for baseline covariates. Analysis was then repeated with physical activity as response value and weight as predictor value. Only participants with a response value preceded by at least three annual response values were included. Adequate data were available for 2811 (30%) of NAVIGATOR participants. Previous weight (χ(2)=16.8; p<0.0001), but not change in weight (χ(2)=0.1; p=0.71) was inversely associated with subsequent step count, indicating lower subsequent levels of physical activity in heavier individuals. Change in step count (χ(2)=5.9; p=0.02) but not previous step count (χ(2)=0.9; p=0.34) was inversely associated with subsequent weight. However, in the context of trajectories already established for weight (χ(2) for previous weight measurements 747.3; p<0.0001) and physical activity (χ(2) for previous step count 432.6; p<0.0001), these effects were of limited clinical importance. While a prospective bidirectional relationship was observed between weight and physical activity, the magnitude of any effect was very small in the context of natural trajectories already established for these variables. NCT00097786. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Measurement of time-dependent CP violation in B 0 → η'K 0 decays
Šantelj, L.; Yusa, Y.; Abdesselam, A.; ...
2014-10-29
We present a measurement of the time-dependent CP violation parameters in B 0 → η'K 0 decays. The measurement is based on the full data sample containing 772×10 6 BB-bar pairs collected at the Υ(4S) resonance using the Belle detector at the KEKB asymmetric-energy e +e - collider. The measured values of the mixing-induced and direct CP violation parameters are: sin 2φ 1 eff = +0.68 ± 0.07 ± 0.03, A η'K0 = +0.03 ± 0.05 ± 0.04, where the first uncertainty is statistical and the second is systematic. The values obtained are the most accurate to date. Furthermore, thesemore » results are consistent with our previous measurements and with the world-average value of sin 2φ 1 measured in B 0 → J/ψK 0 decays.« less
Measurement of time-dependent CP violation in B 0 → η'K 0 decays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Šantelj, L.; Yusa, Y.; Abdesselam, A.
We present a measurement of the time-dependent CP violation parameters in B 0 → η'K 0 decays. The measurement is based on the full data sample containing 772×10 6 BB-bar pairs collected at the Υ(4S) resonance using the Belle detector at the KEKB asymmetric-energy e +e - collider. The measured values of the mixing-induced and direct CP violation parameters are: sin 2φ 1 eff = +0.68 ± 0.07 ± 0.03, A η'K0 = +0.03 ± 0.05 ± 0.04, where the first uncertainty is statistical and the second is systematic. The values obtained are the most accurate to date. Furthermore, thesemore » results are consistent with our previous measurements and with the world-average value of sin 2φ 1 measured in B 0 → J/ψK 0 decays.« less
NASA Technical Reports Server (NTRS)
Brinberg, Herbert R.; Pinelli, Thomas E.; Barclay, Rebecca O.
1995-01-01
Consideration effort has been devoted over the past 30 years to developing methods and means of assessing the value of information. Two approaches - value in exchange and value in use - dominate; however, neither approach enjoys much practical application because validation schema for decision-making is missing. The approaches fail to measure objectively the real costs of acquiring information and the real benefits that information will yield. Moreover, these approaches collectively fail to provide economic justification to build and/or continue to support an information product or service. In addition, the impact of Cyberspace adds a new dimension to the problem. A new paradigm is required to make economic sense in this revolutionary information environment. In previous work, the authors explored the various approaches to measuring the value of information and concluded that, in large measure, these methods were unworkable concepts and constructs. Instead, they proposed several axioms for valuing information. Most particularly they concluded that the 'value of information cannot be measured in the absence of a specific task, objective, or goal.' This paper builds on those axioms and describes under which circumstances information can be measured in objective and actionable terms. This paper also proposes a methodology for undertaking such measures and validating the results.
The Dynamics of Glomerular Ultrafiltration in the Rat
Brenner, Barry M.; Troy, Julia L.; Daugharty, Terrance M.
1971-01-01
Using a unique strain of Wistar rats endowed with glomeruli situated directly on the renal cortical surface, we measured glomerular capillary pressures using servo-nulling micropipette transducer techniques. Pressures in 12 glomerular capillaries from 7 rats averaged 60 cm H2O, or approximately 50% of mean systemic arterial values. Wave form characteristics for these glomerular capillaries were found to be remarkably similar to those of the central aorta. From similarly direct estimates of hydrostatic pressures in proximal tubules, and colloid osmotic pressures in systemic and efferent arteriolar plasmas, the net driving force for ultrafiltration was calculated. The average value of 14 cm H2O is lower by some two-thirds than the majority of estimates reported previously based on indirect techniques. Single nephron GFR (glomerular filtration rate) was also measured in these rats, thereby permitting calculation of the glomerular capillary ultrafiltration coefficient. The average value of 0.044 nl sec−1 cm H2O−1 glomerulus−1 is at least fourfold greater than previous estimates derived from indirect observations. PMID:5097578
Libet's experiment: Questioning the validity of measuring the urge to move.
Dominik, Tomáš; Dostál, Daniel; Zielina, Martin; Šmahaj, Jan; Sedláčková, Zuzana; Procházka, Roman
2017-03-01
The time of subjectively registered urge to move (W) constituted the central point of most Libet-style experiments. It is therefore crucial to verify the W validity. Our experiment was based on the assumption that the W time is inferred, rather than introspectively perceived. We used the rotating spot method to gather the W reports together with the reports of the subjective timing of actual movement (M). The subjects were assigned the tasks in two different orders. When measured as first in the respective session, no significant difference between W and M values was found, which suggests that uninformed subjects tend to confuse W for M reports. Moreover, we found that W values measured after the M task were significantly earlier than W values measured before M. This phenomenon suggests that the apparent difference between W and M values is in fact caused by the subjects' previous experience with M measurements. Copyright © 2017 Elsevier Inc. All rights reserved.
Measurement of the π 0 → e + e - γ Dalitz decay at the Mainz Microtron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adlarson, P.; Afzal, F.; Aguar-Bartolomé, P.
The Dalitz decay π 0 → e +e -γ has been measured in the γp → π 0p reaction with the A2 tagged-photon facility at the Mainz Microtron, MAMI. The value obtained for the slope parameter of the π 0 electromagnetic transition form factor, a π= 0.030 ± 0.010 tot, is in agreement with existing measurements of this decay and with recent theoretical calculations. The uncertainty obtained in the value of a π is lower than in previous results based on the π 0 → e +e -γ decay.
NASA Technical Reports Server (NTRS)
Bendura, R. J.; Crumbly, K. H.
1977-01-01
Surface-level exhaust effluent measurements of HCl, CO, and particulates, ground-cloud behavior, and some comparisons with model predictions for the launch of a Titan 3 rocket are presented along with a limited amount of airborne sampling measurements of other cloud species (O3, NO, NOX). Values above background levels for these effluents were obtained at 20 of the 30 instrument sites; these values were lower than model predictions and did not exceed public health standards. Cloud rise rate, stabilization altitude, and volume are compared with results from previous launches.
Measurement of the π 0 → e + e - γ Dalitz decay at the Mainz Microtron
Adlarson, P.; Afzal, F.; Aguar-Bartolomé, P.; ...
2017-02-09
The Dalitz decay π 0 → e +e -γ has been measured in the γp → π 0p reaction with the A2 tagged-photon facility at the Mainz Microtron, MAMI. The value obtained for the slope parameter of the π 0 electromagnetic transition form factor, a π= 0.030 ± 0.010 tot, is in agreement with existing measurements of this decay and with recent theoretical calculations. The uncertainty obtained in the value of a π is lower than in previous results based on the π 0 → e +e -γ decay.
Added value measures in education show genetic as well as environmental influence.
Haworth, Claire M A; Asbury, Kathryn; Dale, Philip S; Plomin, Robert
2011-02-02
Does achievement independent of ability or previous attainment provide a purer measure of the added value of school? In a study of 4000 pairs of 12-year-old twins in the UK, we measured achievement with year-long teacher assessments as well as tests. Raw achievement shows moderate heritability (about 50%) and modest shared environmental influences (25%). Unexpectedly, we show that for indices of the added value of school, genetic influences remain moderate (around 50%), and the shared (school) environment is less important (about 12%). The pervasiveness of genetic influence in how and how much children learn is compatible with an active view of learning in which children create their own educational experiences in part on the basis of their genetic propensities.
Koenig, Bruce E; Lacey, Douglas S
2014-07-01
In this research project, nine small digital audio recorders were tested using five sets of 30-min recordings at all available recording modes, with consistent audio material, identical source and microphone locations, and identical acoustic environments. The averaged direct current (DC) offset values and standard deviations were measured for 30-sec and 1-, 2-, 3-, 6-, 10-, 15-, and 30-min segments. The research found an inverse association between segment lengths and the standard deviation values and that lengths beyond 30 min may not meaningfully reduce the standard deviation values. This research supports previous studies indicating that measured averaged DC offsets should only be used for exclusionary purposes in authenticity analyses and exhibit consistent values when the general acoustic environment and microphone/recorder configurations were held constant. Measured average DC offset values from exemplar recorders may not be directly comparable to those of submitted digital audio recordings without exactly duplicating the acoustic environment and microphone/recorder configurations. © 2014 American Academy of Forensic Sciences.
Gas-Phase Lithium Cation Basicity: Revisiting the High Basicity Range by Experiment and Theory
NASA Astrophysics Data System (ADS)
Mayeux, Charly; Burk, Peeter; Gal, Jean-Francois; Kaljurand, Ivari; Koppel, Ilmar; Leito, Ivo; Sikk, Lauri
2014-09-01
According to high level calculations, the upper part of the previously published FT-ICR lithium cation basicity (LiCB at 373 K) scale appeared to be biased by a systematic downward shift. The purpose of this work was to determine the source of this systematic difference. New experimental LiCB values at 373 K have been measured for 31 ligands by proton-transfer equilibrium techniques, ranging from tetrahydrofuran (137.2 kJ mol-1) to 1,2-dimethoxyethane (202.7 kJ mol-1). The relative basicities (ΔLiCB) were included in a single self-consistent ladder anchored to the absolute LiCB value of pyridine (146.7 kJ mol-1). This new LiCB scale exhibits a good agreement with theoretical values obtained at G2(MP2) level. By means of kinetic modeling, it was also shown that equilibrium measurements can be performed in spite of the formation of Li+ bound dimers. The key feature for achieving accurate equilibrium measurements is the ion trapping time. The potential causes of discrepancies between the new data and previous experimental measurements were analyzed. It was concluded that the disagreement essentially finds its origin in the estimation of temperature and the calibration of Cook's kinetic method.
A Boltzmann constant determination based on Johnson noise thermometry
NASA Astrophysics Data System (ADS)
Flowers-Jacobs, N. E.; Pollarolo, A.; Coakley, K. J.; Fox, A. E.; Rogalla, H.; Tew, W. L.; Benz, S. P.
2017-10-01
A value for the Boltzmann constant was measured electronically using an improved version of the Johnson Noise Thermometry (JNT) system at the National Institute of Standards and Technology (NIST), USA. This system is different from prior ones, including those from the 2011 determination at NIST and both 2015 and 2017 determinations at the National Institute of Metrology (NIM), China. As in all three previous determinations, the main contribution to the combined uncertainty is the statistical uncertainty in the noise measurement, which is mitigated by accumulating and integrating many weeks of cross-correlated measured data. The second major uncertainty contribution also still results from variations in the frequency response of the ratio of the measured spectral noise of the two noise sources, the sense resistor at the triple-point of water and the superconducting quantum voltage noise source. In this paper, we briefly describe the major differences between our JNT system and previous systems, in particular the input circuit and approach we used to match the frequency responses of the two noise sources. After analyzing and integrating 50 d of accumulated data, we determined a value: k~=1.380 642 9(69)× {{10}-23} J K-1 with a relative standard uncertainty of 5.0× {{10}-6} and relative offset -4.05× {{10}-6} from the CODATA 2014 recommended value.
Investigation into the semimagic nature of the tin isotopes through electromagnetic moments
Allmond, J. M.; Stuchbery, A. E.; Galindo-Uribarri, A.; ...
2015-10-19
A complete set of electromagnetic moments, B(E2;0 + 1 2 + 1), Q(2 + 1), and g(2 + 1), have been measured from Coulomb excitation of semi-magic 112,114,116,118,120,122,124Sn (Z = 50) on natural carbon and titanium targets. The magnitude of the B(E2) values, measured to a precision of ~4%, disagree with a recent lifetime study [Phys. Lett. B 695, 110 (2011)] that employed the Doppler- shift attenuation method. The B(E2) values show an overall enhancement compared with recent theoretical calculations and a clear asymmetry about midshell, contrary to naive expectations. A new static electric quadrupole moment, Q(2 + 1), hasmore » been measured for 114Sn. The static quadrupole moments are generally consistent with zero but reveal an enhancement near midshell; this had not been previously observed. The magnetic dipole moments are consistent with previous measurements and show a near monotonic decrease in value with neutron number. The current theory calculations fail to reproduce the electromagnetic moments of the tin isotopes. The role of 2p-2h and 4p-4h intruders, which are lowest in energy at mid shell and outside of current model spaces, needs to be investigated in the future.« less
Half-lives of 214Pb and 214Bi.
Martz, D E; Langner, G H; Johnson, P R
1991-10-01
New measurements on chemically separated samples of 214Bi have yielded a mean half-life value of 19.71 +/- 0.02 min, where the error quoted is twice the standard deviation of the mean based on 23 decay runs. This result provides strong support for the historic 19.72 +/- 0.04 min half-life value and essentially excludes the 19.9-min value, both reported in previous studies. New measurements of the decay rate of 222Rn progeny activity initially in radioactive equilibrium have yielded a value of 26.89 +/- 0.03 min for the half-life of 214Pb, where the error quoted is twice the standard deviation of the mean based on 12 decay runs. This value is 0.1 min longer than the currently accepted 214Pb half-value of 26.8 min.
Inoue, Kaori; Goto, Atsushi; Kishimoto, Miyako; Tsujimoto, Tetsuro; Yamamoto-Honda, Ritsuko; Noto, Hiroshi; Kajio, Hiroshi; Terauchi, Yasuo; Noda, Mitsuhiko
2015-12-01
Glycated hemoglobin (HbA1c) and glycated albumin (GA) are frequently used as glycemic control markers. However, these markers are influenced by alterations in hemoglobin and albumin metabolism. Thus, conditions such as anemia, chronic renal failure, hypersplenism, chronic liver diseases, hyperthyroidism, hypoalbuminemia, and pregnancy need to be considered when interpreting HbA1c or GA values. Using data from patients with normal albumin and hemoglobin metabolism, we previously established a linear regression equation describing the GA value versus the HbA1c value to calculate an extrapolated HbA1c (eHbA1c) value for the accurate evaluation of glycemic control. In this study, we investigated the difference between the measured HbA1c and the eHbA1c values for patients with various conditions. Data sets for a total of 2461 occasions were obtained from 731 patients whose HbA1c and GA values were simultaneously measured. We excluded patients with missing data or changeable HbA1c levels, and patients who had received transfusions or steroids within the previous 3 months. Finally, we included 44 patients with chronic renal failure (CRF), 10 patients who were undergoing hemodialysis (HD), 7 patients with hematological malignancies and a hemoglobin level of less than 10 g/dL (HM), and 12 patients with chronic liver diseases (CLD). In all the groups, the eHbA1c values were significantly higher than the measured HbA1c values. The median difference was 0.75 % (95 % CI 0.40-1.10 %, P for the difference is <0.001) in the CRF group, 0.80 % (95 % CI 0.30-1.65 %, P for the difference is 0.041) in the HD group, 0.90 % (95 % CI 0.90-1.30 %, P for the difference is 0.028) in the HM group, and 0.85 % (95 % CI 0.40-1.50 %, P for the difference is 0.009) in the CLD group. We found that the measured HbA1c values were lower than the eHbA1c values in each of the groups.
Rotational Velocity Determinations for 118 δ Scuti Variables
NASA Astrophysics Data System (ADS)
Bush, Tabitha C.; Hintz, Eric G.
2008-09-01
A calibration method is presented for the determination of projected rotational velocities of 118 δ Scuti variables from FWHM measurements of metal lines near 4500 Å. The calibration relation used was derived from measurements of 29 stars. Of the 44 stars brighter than 8th magnitude and north of -1° declination which did not have values in the Rodríguez catalog (Rodríguez, E., López González, M. J., & López de Coca, P. 2000, A&AS, 144, 469) we present values for 38. In addition, we present new projected rotational velocity, vsin i, values for 10 stars south of -1° or fainter than 8th magnitude for a total of 48 vsin i values for stars with no previously published values.
Analysis of historical delta values for IAEA/LANL NDA training courses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geist, William; Santi, Peter; Swinhoe, Martyn
2009-01-01
The Los Alamos National Laboratory (LANL) supports the International Atomic Energy Agency (IAEA) by providing training for IAEA inspectors in neutron and gamma-ray Nondestructive Assay (NDA) of nuclear material. Since 1980, all new IAEA inspectors attend this two week course at LANL gaining hands-on experience in the application of NDA techniques, procedures and analysis to measure plutonium and uranium nuclear material standards with well known pedigrees. As part of the course the inspectors conduct an inventory verification exercise. This exercise provides inspectors the opportunity to test their abilities in performing verification measurements using the various NDA techniques. For an inspector,more » the verification of an item is nominally based on whether the measured assay value agrees with the declared value to within three times the historical delta value. The historical delta value represents the average difference between measured and declared values from previous measurements taken on similar material with the same measurement technology. If the measurement falls outside a limit of three times the historical delta value, the declaration is not verified. This paper uses measurement data from five years of IAEA courses to calculate a historical delta for five non-destructive assay methods: Gamma-ray Enrichment, Gamma-ray Plutonium Isotopics, Passive Neutron Coincidence Counting, Active Neutron Coincidence Counting and the Neutron Coincidence Collar. These historical deltas provide information as to the precision and accuracy of these measurement techniques under realistic conditions.« less
The measurement of place attachment: validity and generalizability of a psychometric approach
Daniel R. Williams; Jerry J. Vaske
2003-01-01
To enhance land managersâ ability to address deeper landscape meanings and place-specific symbolic values in natural resource decision making, this study evaluated the psychometric properties of a place attachment measure designed to capture the extent of emotions and feelings people have for places. Building on previous measurement efforts, this study examined the...
Khaw, Mel W.; Grab, Denise A.; Livermore, Michael A.; Vossler, Christian A.; Glimcher, Paul W.
2015-01-01
Environmental public goods—including national parks, clean air/water, and ecosystem services—provide substantial benefits on a global scale. These goods have unique characteristics in that they are typically “nonmarket” goods, with values from both use and passive use that accrue to a large number of individuals both in current and future generations. In this study, we test the hypothesis that neural signals in areas correlated with subjective valuations for essentially all other previously studied categories of goods (ventromedial prefrontal cortex and ventral striatum) also correlate with environmental valuations. We use contingent valuation (CV) as our behavioral tool for measuring valuations of environmental public goods. CV is a standard stated preference approach that presents survey respondents with information on an issue and asks questions that help policymakers determine how much citizens are willing to pay for a public good or policy. We scanned human subjects while they viewed environmental proposals, along with three other classes of goods. The presentation of all four classes of goods yielded robust and similar patterns of temporally synchronized brain activation within attentional networks. The activations associated with the traditional classes of goods replicate previous correlations between neural activity in valuation areas and behavioral preferences. In contrast, CV-elicited values for environmental proposals did not correlate with brain activity at either the individual or population level. For a sub-population of participants, CV-elicited values were correlated with activity within the dorsomedial prefrontal cortex, a region associated with cognitive control and shifting decision strategies. The results show that neural activity associated with the subjective valuation of environmental proposals differs profoundly from the neural activity associated with previously examined goods and preference measures. PMID:26221734
Modern reindeer and mice: revised phosphate-water isotope equations
NASA Astrophysics Data System (ADS)
Longinelli, Antonio; Iacumin, Paola; Davanzo, Silvana; Nikolaev, Vladimir
2003-09-01
The oxygen isotope composition of bone and tooth phosphate of 34 mice specimens ( Pitymus sp., Microtus arvalis and Arvicola terrestris) coming from seven different locations in Italy, Germany and Switzerland was measured by means of well-established techniques. These measurements were carried out with the purpose of establishing quantitative relationships between the δ 18O p from different mice genera and the mean δ 18O w values and to compare these data to previous measurements carried out on various specimens belonging to the genus Apodemus. The three genera studied showed a similar behaviour when compared to the mean δ 18O w values. The slope of the equation calculated for these three genera is significantly different from the slope obtained from Apodemus specimens. Reconsidering the δ 18O w values suggested in the case of Apodemus due to the small number of data available at that time, it seems that these values are too negative by 0.5 to about 1.5‰. If so, the Apodemus equation becomes almost identical to the equation calculated for the new mice values and, consequently, one could conclude that several micromammal genera and species might behave in the same way and obey the same relationship with the mean δ 18O w values. A set of 25 samples of modern reindeer skeletal material from Spitzbergen, Russia and Siberia was also studied with the aim of improving the reindeer isotope equation obtained from a previous study. In fact, the slope of that equation was somehow uncertain due to a rather large range of isotope values obtained from each group of reindeers coming from the same location. The new results confirm such 'anomalous' behaviour already shown by other mammals and probably related to dietary behaviours, water fluxes with the environment and isotopic composition of ingested food and water rather than to imperfect equilibrium conditions with environmental water. However, the equation calculated from both the old and new, statistically more significant, isotope results is not far from the previous one.
Reactions of PO(x)Cl(y)-ions with O(2)(a1-delta-g), H(2)O, and Cl(2) at 298 K
2008-03-10
branching ratio values calculated in this way for the 02(X) reaction differ slightly from the previous SIFT measurement [17]. However, the difference is...been measured in a selected ion flow tube (SIFT) at 298 K. A mixture of 02(a’Ag) in 02 has been produced using a recently designed chemical singlet...oxygen generator (sparger) with an emission detection scheme adopted previously in our laboratory. The experiments continue a series of investigations
Colorimetric values of esthetic stainless steel crowns.
Hosoya, Yumiko; Omachi, Koichi; Staninec, Michal
2002-01-01
The colorimetric values of two different kinds of esthetic stainless steel crowns were measured and compared with the colorimetric values of primary anterior teeth in Japanese children. The colorimetric values of resin composite-faced stainless steel crowns (Kinder Krown) and epoxy-coated stainless steel crowns (White Steel Crown) were measured with a color difference meter. The Commission Internationale de Eclairage L*, a*, b*, and delta E*ab values and Munsell value, chroma, and hue were calculated. The data were compared with previously reported colorimetric values of Japanese primary anterior teeth measured with the same color difference meter used in this study. Compared to Japanese primary anterior teeth, Kinder Krown Pedo I and Pedo II showed much higher L* values and lower hue; on the other hand, White Steel Crown showed much higher L*, a*, b* values, much higher value and chroma, and much lower hue. Color analysis revealed that the colors of the White Steel Crown and Kinder Krown Pedo I were substantially different from the color of Japanese primary anterior teeth. The color difference between Pedo II crowns and Japanese primary anterior teeth was relatively high, but the color of Pedo II might be acceptable for clinical use.
Nijran, Kuldip S; Houston, Alex S; Fleming, John S; Jarritt, Peter H; Heikkinen, Jari O; Skrypniuk, John V
2014-07-01
In this second UK audit of quantitative parameters obtained from renography, phantom simulations were used in cases in which the 'true' values could be estimated, allowing the accuracy of the parameters measured to be assessed. A renal physical phantom was used to generate a set of three phantom simulations (six kidney functions) acquired on three different gamma camera systems. A total of nine phantom simulations and three real patient studies were distributed to UK hospitals participating in the audit. Centres were asked to provide results for the following parameters: relative function and time-to-peak (whole kidney and cortical region). As with previous audits, a questionnaire collated information on methodology. Errors were assessed as the root mean square deviation from the true value. Sixty-one centres responded to the audit, with some hospitals providing multiple sets of results. Twenty-one centres provided a complete set of parameter measurements. Relative function and time-to-peak showed a reasonable degree of accuracy and precision in most UK centres. The overall average root mean squared deviation of the results for (i) the time-to-peak measurement for the whole kidney and (ii) the relative function measurement from the true value was 7.7 and 4.5%, respectively. These results showed a measure of consistency in the relative function and time-to-peak that was similar to the results reported in a previous renogram audit by our group. Analysis of audit data suggests a reasonable degree of accuracy in the quantification of renography function using relative function and time-to-peak measurements. However, it is reasonable to conclude that the objectives of the audit could not be fully realized because of the limitations of the mechanical phantom in providing true values for renal parameters.
Viscosity of saturated R152a measured with a vibrating wire viscometer
NASA Astrophysics Data System (ADS)
van der Gulik, P. S.
1995-07-01
Earlier reported values of the viscosity coefficient of the refrigerant R152a (1,1-difluoroethane) have been recalculated with an improved value for the mechanical damping of the vibrating wire viscometer. The measurements were taken along the saturation line both in the saturated liquid and in the saturated vapor every 10 K from 243 up to 393 K by means of a vibrating wire viscometer The damping of the vibration of the wire is a measure for the viscosity provided that the mechanical damping is subtracted. The latter is usually measured in vacuum. It turns out that the damping value measured in this way depends on the vacuum pressure and on the way the wire has been handled before. It appeared that the damping applied previously, measured after 6 days of pumping, is too small, resulting in values of the viscosity coefficient which are too large. The effect on the data for the saturated-liquid viscosity is small, but the new saturated-vapor viscosity data agree much better with the unsaturated-vapor data reported by Takahashi et al.
Biomarker measurements are used in three ways: 1) evaluating the time course and distribution of a chemical in the body, 2) estimating previous exposure or dose, and 3) assessing disease state. Blood and urine measurements are the primary methods employed. Of late, it has been ...
ERIC Educational Resources Information Center
Wilkinson, Lindsay R.; Shippee, Tetyana P.; Ferraro, Kenneth F.
2012-01-01
Occupational mobility is highly valued in American society, but is it consequential to women's health? Previous studies have yielded inconsistent results, but most measured occupational mobility by identifying transitions across occupational categories. Drawing from cumulative inequality theory, this study (1) compares objective and subjective…
New Measurement of the 60Fe Half-Life.
Rugel, G; Faestermann, T; Knie, K; Korschinek, G; Poutivtsev, M; Schumann, D; Kivel, N; Günther-Leopold, I; Weinreich, R; Wohlmuther, M
2009-08-14
We have made a new determination of the half-life of the radioactive isotope 60Fe using high precision measurements of the number of 60Fe atoms and their activity in a sample containing over 10(15) 60Fe atoms. Our new value for the half-life of 60Fe is (2.62+/-0.04) x 10(6) yr, significantly above the previously reported value of (1.49+/-0.27) x 10(6) yr. Our new measurement for the lifetime of 60Fe has significant implications for interpretations of galactic nucleosynthesis, for determinations of formation time scales of solids in the early Solar System, and for the interpretation of live 60Fe measurements from supernova-ejecta deposits on Earth.
Tousignant, Michel; Smeesters, Cécil; Breton, Anne-Marie; Breton, Emilie; Corriveau, Hélène
2006-04-01
This study compared range of motion (ROM) measurements using a cervical range of motion device (CROM) and an optoelectronic system (OPTOTRAK). To examine the criterion validity of the CROM for the measurement of cervical ROM on healthy adults. Whereas measurements of cervical ROM are recognized as part of the assessment of patients with neck pain, few devices are available in clinical settings. Two papers published previously showed excellent criterion validity for measurements of cervical flexion/extension and lateral flexion using the CROM. Subjects performed neck rotation, flexion/extension, and lateral flexion while sitting on a wooden chair. The ROM values were measured by the CROM as well as the OPTOTRAK. The cervical rotational ROM values using the CROM demonstrated a good to excellent linear relationship with those using the OPTOTRAK: right rotation, r = 0.89 (95% confidence interval, 0.81-0.94), and left rotation, r = 0.94 (95% confidence interval, 0.90-0.97). Similar results were also obtained for flexion/extension and lateral flexion ROM values. The CROM showed excellent criterion validity for measurements of cervical rotation. We propose using ROM values measured by the CROM as outcome measures for patients with neck pain.
In vivo estimates of NO and CO conductance for haemoglobin and for lung transfer in humans.
Guénard, Hervé Jean-Pierre; Martinot, Jean-Benoit; Martin, Sebastien; Maury, Bertrand; Lalande, Sophie; Kays, Christian
2016-07-01
Membrane conductance (Dm) and capillary lung volume (Vc) derived from NO and CO lung transfer measurements in humans depend on the blood conductance (θ) values of both gases. Many θ values have been proposed in the literature. In the present study, measurements of CO and NO transfer while breathing 15% or 21% O2 allowed the estimation of θNO and the calculation of the optimal equation relating 1/θCO to pulmonary capillary oxygen pressure (PcapO2). In 10 healthy subjects, the mean calculated θNO value was similar to the θNO value previously reported in the literature (4.5mmHgmin(-1)) provided that one among three θCO equations from the literature was chosen. Setting 1/θCO=a·PcapO2+b, optimal values of a and b could be chosen using two methods: 1) by minimizing the difference between Dm/Vc ratios for any PcapO2, 2) by establishing a linear equation relating a and b. Using these methods, we are proposing the equation 1/θCO=0.0062·PcapO2+1.16, which is similar to two equations previously reported in the literature. With this set of θ values, DmCO reached the morphometric range. Copyright © 2016 Elsevier B.V. All rights reserved.
QED test and nuclear radius determination of helium atom by laser spectroscopy
NASA Astrophysics Data System (ADS)
Pavone, F. S.
1995-01-01
The 23S1-33P0 4He transition at λ = 389 nm is measured with respect to a previously frequency calibrated 87Rb two-photon transition at 2λ = 778 nm. The 4He absolute frequency is 770 732 839 058 (190) kHz, with an accuracy of 2.4 parts in 1010. A Lamb shift value of + 4057.61 (79) MHz, with 600 kHz uncertainty arising from the theoretical position of the 33P0 energy level, is extracted for the 23S1. This value is more than two orders of magnitude more accurate than the current best theoretical predictions. By means of a novel heterodyne spectrometer using only one laser tuned at the atomic frequency, we have measured for the first time the 3He-4He isotope separation for the 23S1-33P0 transition at 389 nm. Our experimental result of 45 394 425 (140) kHz, for the F = 1/2-1/2 3He component, is compared with the theoretical prediction which has similar accuracy and depends also on the rms nuclear radius of 3He. For this we determine a preliminary value of 1.923 (37) fm which shows a slight discrepancy with previous values obtained by extrapolation to zero momentum transfer from high energy scattering measurements.
Ultra-precise single-ion atomic mass measurements on deuterium and helium-3
NASA Astrophysics Data System (ADS)
Zafonte, S. L.; Van Dyck, R. S., Jr.
2015-04-01
The former University of Washington Penning Trap Mass Spectrometer (UW-PTMS), now located at the Max Planck Institute for Nuclear Physics in Heidelberg, Germany, was used in the decade before the move to determine new values for the deuteron atomic mass, M (2H+) = 2.013 553 212 745(40) u, and the deuterium atomic mass, M (2H) = 2.014 101 778 052(40) u, both of which are now more than an order-of-magnitude more accurate than the previous best 1994-MIT measurements of these quantities. The new value for the deuteron’s mass can then be used with the accepted 2010-CODATA proton mass and the most recent 1999-measurement of the 2.2 MeV gamma-ray binding energy of the deuteron to refine the neutron’s mass to mn = 1.008 664 916 018(435) u which has about half the uncertainty relative to the value computed using that previous 1994-MIT deuterium measurement. As a result, further improvements of mn must now come from a more accurate determination of the wavelength of this gamma ray. In this same period of time, this spectrometer has also been used to determine new values for the helion atomic mass, M (3He2+) = 3.014 932 246 668(43) u, and the neutral helium-3 atomic mass, M (3He) = 3.016 029 321 675(43) u, which are both about 60 times more accurate than the 2006-SMILETRAP measurements, but disagree with the 4.4-times less-accurate 2015-Florida-State measurements by 0.76 nu. It is expected that these helium-3 results will be used in the future 3H/3He mass ratio (to be determined by the Heidelberg, Germany version of the old UW-PTMS) in order to generate a more accurate value for the tritium atomic mass.
455 N St Clair St, August 2012, Lindsay Light Radiological Survey
The field gamma measurements within the spoil materials generated during the drilling process did not exceed the respective threshold values previously stated withthe maximum unshielded gamma reading observed being 5,500 cpm.
Stenhouse, Rosie; Snowden, Austyn; Young, Jenny; Carver, Fiona; Carver, Hannah; Brown, Norrie
2016-08-01
Reports of poor nursing care have focused attention on values based selection of candidates onto nursing programmes. Values based selection lacks clarity and valid measures. Previous caring experience might lead to better care. Emotional intelligence (EI) might be associated with performance, is conceptualised and measurable. To examine the impact of 1) previous caring experience, 2) emotional intelligence 3) social connection scores on performance and retention in a cohort of first year nursing and midwifery students in Scotland. A longitudinal, quasi experimental design. Adult and mental health nursing, and midwifery programmes in a Scottish University. Adult, mental health and midwifery students (n=598) completed the Trait Emotional Intelligence Questionnaire-short form and Schutte's Emotional Intelligence Scale on entry to their programmes at a Scottish University, alongside demographic and previous caring experience data. Social connection was calculated from a subset of questions identified within the TEIQue-SF in a prior factor and Rasch analysis. Student performance was calculated as the mean mark across the year. Withdrawal data were gathered. 598 students completed baseline measures. 315 students declared previous caring experience, 277 not. An independent-samples t-test identified that those without previous caring experience scored higher on performance (57.33±11.38) than those with previous caring experience (54.87±11.19), a statistically significant difference of 2.47 (95% CI, 0.54 to 4.38), t(533)=2.52, p=.012. Emotional intelligence scores were not associated with performance. Social connection scores for those withdrawing (mean rank=249) and those remaining (mean rank=304.75) were statistically significantly different, U=15,300, z=-2.61, p$_amp_$lt;0.009. Previous caring experience led to worse performance in this cohort. Emotional intelligence was not a useful indicator of performance. Lower scores on the social connection factor were associated with withdrawal from the course. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mechanical property studies of human gallstones.
Stranne, S K; Cocks, F H; Gettliffe, R
1990-08-01
The recent development of gallstone fragmentation methods has increased the significance of the study of the mechanical properties of human gallstones. In the present work, fracture strength data and microhardness values of gallstones of various chemical compositions are presented as tested in both dry and simulated bile environments. Generally, both gallstone hardness and fracture strength values were significantly less than kidney stone values found in previous studies. However, a single calcium carbonate stone was found to have an outer shell hardness exceeding those values found for kidney stones. Diametral compression measurements in simulated bile conclusively demonstrated low gallstone fracture strength as well as brittle fracture in the stones tested. Based on the results of this study, one may conclude that the wide range of gallstone microhardnesses found may explain the reported difficulties previous investigators have experienced using various fragmentation techniques on specific gallstones. Moreover, gallstone mechanical properties may be relatively sensitive to bile-environment composition.
Puri, S; Chickos, J S; Welsh, W J
2001-04-01
The vaporization enthalpies of 16 polychlorinated biphenyls have been determined by correlation gas chromatography. This study was prompted by the realization that the vaporization enthalpy of the standard compounds used in previous studies, octadecane and eicosane, were values measured at 340 and 362 K, respectively, rather than at 298 K. Adjustment to 298 K amounts to a 7-8 kJ/mol increment in the values. With the inclusion of this adjustment, vaporization enthalpies evaluated by correlation gas chromatography are in good agreement with the values determined previously in the literature. The present results are based on the vaporization enthalpies of several standards whose values are well established in the literature. The standards include a variety of n-alkanes and various chlorinated hydrocarbons. The vaporization enthalpies of PCBs increased with the number of chlorine atoms and were found to be larger for meta- and para-substituted polychlorinated biphenyls.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M. S.; Coleman, C. J.; Diprete, D. P.
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H samples ranged from 53.7 mg/L for the surface sample to 57.0 mg/L in the sub-surface sample. The Tank 43H samples showed uranium concentrations of 46.2 mg/L for the surface sample and 45.7 mg/L in the sub-surface sample. The U-235 percentage was 0.63% in the Tank 38H samples and 0.62% in the Tank 43H samples. The total uranium and percent U-235 results appear consistent with recent Tank 38H and Tank 43H uranium measurements. The plutonium results for the Tank 38Hmore » surface sample are slightly higher than recent sample results, while the Tank 43H plutonium results are within the range of values measured on previous samples. The Cs-137 results for the Tank 38H surface and subsurface samples are slightly higher than the concentrations measured in recent samples. The Cs-137 results for the two Tank 43H samples are within the range of values measured on previous samples. The comparison of the sum of the cations in each sample versus the sum of the anions shows a difference of 23% for the Tank 38H surface sample and 18% for the Tank 43H surface sample. The four samples show silicon concentrations somewhat lower than the previous samples with values ranging from 80.2 to 105 mg/L.« less
Z = 50 core stability in 110Sn from magnetic-moment and lifetime measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumbartzki, G. J.; Benczer-Koller, N.; Speidel, K. -H.
2016-04-18
In this study, the structure of the semimagic Sn50 isotopes were previously studied via measurements of B(E2;2 1 + → 0 1 +) and g factors of 2 1 + states. The values of the B(E2;2 1 +) in the isotopes below midshell at N = 66 show an enhancement in collectivity, contrary to predictions from shell-model calculations. This work presents the first measurement of the 2 1 + and 4 1 + states' magnetic moments in the unstable neutron-deficient 110Sn. The g factors provide complementary structure information to the interpretation of the observed B(E2) values.
Quadrupole deformed and octupole collective bands in 228Ra
NASA Astrophysics Data System (ADS)
Gulda, K.; Mach, H.; Aas, A. J.; Borge, M. J. G.; Burke, D. G.; Fogelberg, B.; Gietz, H.; Grant, I. S.; Hagebo, E.; Hill, P.; Hoff, P.; Kaffrell, N.; Kurcewicz, W.; Lindroth, A.; Løvhøiden, G.; Martinez, T.; Mattsson, S.; Naumann, R. A.; Nybø, K.; Nyman, G.; Rubio, B.; Sanchez-Vega, M.; Tain, J. L.; Taylor, R. B. E.; Tengblad, O.; Thorsteinsen, T. F.; Isolde Collaboration
1998-06-01
Spins and parities for collective states in 228Ra have been determined from conversion electron measurements with a mini-orange β spectrometer. The fast-timing βγγ( t) method has been used to measure lifetimes of T {1}/{2} = 550(20) ps and 181 (3) ps for the 2 1+ and 4 1+ aembers of the K = 0 + band, and T {1}/{2} ⩽ 7 ps and ⩽6 ps for the 1 1- and 3 1- members of the K = 0 - band, respectively The quadrupole moments, Q0 deduced from the B (E2; 2 1+ → 0 1+) and B (E2; 4 1+ → 2 1+) rates are in good agreement with the previously measured value and the systematics of the region. However, the B(E1) rates of ⩾4 × 10 -4 e 2 fm 2, which represent the first B(E1) measurements for this nucleus, are at least 25 times larger than the value previously suggested for 228Ra. The new results are consistent with the B(E1) rates recently measured for the neighbouring 227Ra and reveal octupole correlations in 228Ra.
Hydrostatic compression of Fe(1-x)O wuestite
NASA Technical Reports Server (NTRS)
Jeanloz, R.; Sato-Sorensen, Y.
1986-01-01
Hydrostatic compression measurements on Fe(0.95)O wuestite up to 12 GPa yield a room temperature value for the isothermal bulk modulus of K(ot) = 157 (+ or - 10) GPa at zero pressure. This result is in accord with previous hydrostatic and nonhydrostatic measurements of K(ot) for wuestites of composition: 0.89 = Fe/O 0.95. Dynamic measurements of the bulk modulus by ultrasonic, shock-wave and neutron-scattering experiments tend to yield a larger value: K(ot) approximately 180 GPa. The discrepancy between static and dynamic values cannot be explained by the variation of K(ot) with composition, as has been proposed. This conclusion is based on high-precision compression data and on theoretical models of the effects of defects on elastic constants. Barring serious errors in the published measurements, the available data suggest that wuestite exhibits a volume relaxation under pressure.
Precision measurement of the electromagnetic dipole strengths in Be11
NASA Astrophysics Data System (ADS)
Kwan, E.; Wu, C. Y.; Summers, N. C.; Hackman, G.; Drake, T. E.; Andreoiu, C.; Ashley, R.; Ball, G. C.; Bender, P. C.; Boston, A. J.; Boston, H. C.; Chester, A.; Close, A.; Cline, D.; Cross, D. S.; Dunlop, R.; Finlay, A.; Garnsworthy, A. B.; Hayes, A. B.; Laffoley, A. T.; Nano, T.; Navrátil, P.; Pearson, C. J.; Pore, J.; Quaglioni, S.; Svensson, C. E.; Starosta, K.; Thompson, I. J.; Voss, P.; Williams, S. J.; Wang, Z. M.
2014-05-01
The electromagnetic dipole strength in Be11 between the bound states has been measured using low-energy projectile Coulomb excitation at bombarding energies of 1.73 and 2.09 MeV/nucleon on a Pt196 target. An electric dipole transition probability B(E1;1/2-→1/2+)=0.102(2) e2fm was determined using the semi-classical code Gosia, and a value of 0.098(4) e2fm was determined using the Extended Continuum Discretized Coupled Channels method with the quantum mechanical code FRESCO. These extracted B(E1) values are consistent with the average value determined by a model-dependent analysis of intermediate energy Coulomb excitation measurements and are approximately 14% lower than that determined by a lifetime measurement. The much-improved precisions of 2% and 4% in the measured B(E1) values between the bound states deduced using Gosia and the Extended Continuum Discretized Coupled Channels method, respectively, compared to the previous accuracy of ˜10% will help in our understanding of and better improve the realistic inter-nucleon interactions.
Student- and School-Level Belonging and Commitment and Student Smoking, Drinking and Misbehaviour
ERIC Educational Resources Information Center
Bonell, Christopher; Shackleton, Nichola; Fletcher, Adam; Jamal, Farah; Allen, Elizabeth; Mathiot, Anne; Markham, Wolfgang; Aveyard, Paul; Viner, Russell
2017-01-01
Objectives: It has been suggested that students are healthier in schools where more students are committed to school. Previous research has examined this only using a proxy measure of value-added education (a measure of whether school-level attendance and attainment are higher than predicted by students' social profile), finding associations with…
ERIC Educational Resources Information Center
Paez-Blarrina, Marisa; Luciano, Carmen; Gutierrez-Martinez, Olga; Valdivia, Sonsoles; Rodriguez-Valverde, Miguel; Ortega, Jose
2008-01-01
This study compares the effect of an acceptance-based protocol (ACT) and a cognitive control-based (CONT) protocol on three measures of pain coping: tolerance, self-report, and believability. Specific methodological controls were employed to further isolate the role of the value of participating in a pain task, compared to previous investigations…
Duration of serum antibody response to rabies vaccination in horses.
Harvey, Alison M; Watson, Johanna L; Brault, Stephanie A; Edman, Judy M; Moore, Susan M; Kass, Philip H; Wilson, W David
2016-08-15
OBJECTIVE To investigate the impact of age and inferred prior vaccination history on the persistence of vaccine-induced antibody against rabies in horses. DESIGN Serologic response evaluation. ANIMALS 48 horses with an undocumented vaccination history. PROCEDURES Horses were vaccinated against rabies once. Blood samples were collected prior to vaccination, 3 to 7 weeks after vaccination, and at 6-month intervals for 2 to 3 years. Serum rabies virus-neutralizing antibody (RVNA) values were measured. An RVNA value of ≥ 0.5 U/mL was used to define a predicted protective immune response on the basis of World Health Organization recommendations for humans. Values were compared between horses < 20 and ≥ 20 years of age and between horses inferred to have been previously vaccinated and those inferred to be immunologically naïve. RESULTS A protective RVNA value (≥ 0.5 U/mL) was maintained for 2 to 3 years in horses inferred to have been previously vaccinated on the basis of prevaccination RVNA values. No significant difference was evident in response to rabies vaccination or duration of protective RVNA values between horses < 20 and ≥ 20 years of age. Seven horses were poor responders to vaccination. Significant differences were identified between horses inferred to have been previously vaccinated and horses inferred to be naïve prior to the study. CONCLUSIONS AND CLINICAL RELEVANCE A rabies vaccination interval > 1 year may be appropriate for previously vaccinated horses but not for horses vaccinated only once. Additional research is required to confirm this finding and characterize the optimal primary dose series for rabies vaccination.
The Anomalous Magnetic Moment of the Muon
NASA Astrophysics Data System (ADS)
Hughes, Vernon W.; Sichtermann, Ernst P.
2002-12-01
A precise measurement of the anomalous g value, a = (g - 2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron. The result a
High-precision half-life measurements of the T =1 /2 mirror β decays 17F and 33Cl
NASA Astrophysics Data System (ADS)
Grinyer, J.; Grinyer, G. F.; Babo, M.; Bouzomita, H.; Chauveau, P.; Delahaye, P.; Dubois, M.; Frigot, R.; Jardin, P.; Leboucher, C.; Maunoury, L.; Seiffert, C.; Thomas, J. C.; Traykov, E.
2015-10-01
Background: Measurements of the f t values for T =1 /2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the f t values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T =1 /2 β+ emitters, 17F and 33Cl, in order to eliminate the half-life as the leading source of uncertainty in their f t values. Method: Half-lives of 17F and 33Cl were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The 17F half-life result, 64.347 (35) s, precise to ±0.05 % , is a factor of 5 times more precise than the previous world average. The half-life of 33Cl was determined to be 2.5038 (22) s. The current precision of ±0.09 % is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the f t values for both T =1 /2 mirror decays 17F and 33Cl.
Reference-free error estimation for multiple measurement methods.
Madan, Hennadii; Pernuš, Franjo; Špiclin, Žiga
2018-01-01
We present a computational framework to select the most accurate and precise method of measurement of a certain quantity, when there is no access to the true value of the measurand. A typical use case is when several image analysis methods are applied to measure the value of a particular quantitative imaging biomarker from the same images. The accuracy of each measurement method is characterized by systematic error (bias), which is modeled as a polynomial in true values of measurand, and the precision as random error modeled with a Gaussian random variable. In contrast to previous works, the random errors are modeled jointly across all methods, thereby enabling the framework to analyze measurement methods based on similar principles, which may have correlated random errors. Furthermore, the posterior distribution of the error model parameters is estimated from samples obtained by Markov chain Monte-Carlo and analyzed to estimate the parameter values and the unknown true values of the measurand. The framework was validated on six synthetic and one clinical dataset containing measurements of total lesion load, a biomarker of neurodegenerative diseases, which was obtained with four automatic methods by analyzing brain magnetic resonance images. The estimates of bias and random error were in a good agreement with the corresponding least squares regression estimates against a reference.
Scivoletto, Giorgio; Glass, Clive; Anderson, Kim D; Galili, Tal; Benjamin, Yoav; Front, Lilach; Aidinoff, Elena; Bluvshtein, Vadim; Itzkovich, Malka; Aito, Sergio; Baroncini, Ilaria; Benito-Penalva, Jesùs; Castellano, Simona; Osman, Aheed; Silva, Pedro; Catz, Amiram
2015-01-01
Background. A quadratic formula of the Spinal Cord Injury Ability Realization Measurement Index (SCI-ARMI) has previously been published. This formula was based on a model of Spinal Cord Independence Measure (SCIM95), the 95th percentile of the SCIM III values, which correspond with the American Spinal Injury Association Motor Scores (AMS) of SCI patients. Objective. To further develop the original formula. Setting. Spinal cord injury centers from 6 countries and the Statistical Laboratory, Tel-Aviv University, Israel. Methods. SCIM95 of 661 SCI patients was modeled, using a quantile regression with or without adjustment for age and gender, to calculate SCI-ARMI values. SCI-ARMI gain during rehabilitation and its correlations were examined. Results. A new quadratic SCIM95 model was created. This resembled the previously published model, which yielded similar SCIM95 values in all the countries, after adjustment for age and gender. Without this adjustment, however, only 86% of the non-Israeli SCIM III observations were lower than those SCIM95 values (P < .0001). Adding the variables age and gender to the new model affected the SCIM95 value significantly (P < .04). Adding country information did not add a significant effect (P > .1). SCI-ARMI gain was positive (38.8 ± 22 points, P < .0001) and correlated weakly with admission age and AMS. Conclusions. The original quadratic SCI-ARMI formula is valid for an international population after adjustment for age and gender. The new formula considers more factors that affect functional ability following SCI. © The Author(s) 2014.
NASA Astrophysics Data System (ADS)
Apel, W. D.; Arteaga-Velázquez, J. C.; Bähren, L.; Bekk, K.; Bertaina, M.; Biermann, P. L.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Cantoni, E.; Chiavassa, A.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Falcke, H.; Fuchs, B.; Gemmeke, H.; Grupen, C.; Haungs, A.; Heck, D.; Hiller, R.; Hörandel, J. R.; Horneffer, A.; Huber, D.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Krömer, O.; Kuijpers, J.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Melissas, M.; Morello, C.; Nehls, S.; Oehlschläger, J.; Palmieri, N.; Pierog, T.; Rautenberg, J.; Rebel, H.; Roth, M.; Rühle, C.; Saftoiu, A.; Schieler, H.; Schmidt, A.; Schoo, S.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Weindl, A.; Wochele, J.; Zabierowski, J.; Zensus, J. A.
2016-02-01
LOPES was a digital antenna array detecting the radio emission of cosmic-ray air showers. The calibration of the absolute amplitude scale of the measurements was done using an external, commercial reference source, which emits a frequency comb with defined amplitudes. Recently, we obtained improved reference values by the manufacturer of the reference source, which significantly changed the absolute calibration of LOPES. We reanalyzed previously published LOPES measurements, studying the impact of the changed calibration. The main effect is an overall decrease of the LOPES amplitude scale by a factor of 2.6 ± 0.2, affecting all previously published values for measurements of the electric-field strength. This results in a major change in the conclusion of the paper 'Comparing LOPES measurements of air-shower radio emission with REAS 3.11 and CoREAS simulations' published by Apel et al. (2013) : With the revised calibration, LOPES measurements now are compatible with CoREAS simulations, but in tension with REAS 3.11 simulations. Since CoREAS is the latest version of the simulation code incorporating the current state of knowledge on the radio emission of air showers, this new result indicates that the absolute amplitude prediction of current simulations now is in agreement with experimental data.
Schneider, Christopher; Newhauser, Wayne; Farah, Jad
2015-05-18
Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation.
Negative measurement sensitivity values of planar capacitive imaging probes
NASA Astrophysics Data System (ADS)
Yin, Xiaokang; Chen, Guoming; Li, Wei; Hutchins, David
2014-02-01
The measurement sensitivity distribution of planar capacitive imaging (CI) probes describes how effectively each region in the sensing area is contributing to the measured charge signal on the sensing electrode. It can be used to determine the imaging ability of a CI probe. It is found in previous work that, there are regions in the sensing area where the change of the charge output and the change of targeting physical parameter are of opposite trends. This opposite correlation implies that the measurement sensitivity values in such regions are negative. In this work, the cause of negative sensitivity is discussed. Experiments are also designed and performed so as to verify the existence of negative sensitivity and study the factors that may affect the negative sensitivity distributions.
479 N Columbus Dr, March 2012, Lindsay Light Radiological Survey
field gamma measurements did not exceed the respective field instrument threshold values previously stated and ranged from aminimum of 4,500 cpm unshielded to a maximum of 5,700 cpm shielded in the bottom of the excavation.
600 N McClurg Ct, April 2012, Lindsay Light Radiological Survey
Field gamma measurements did not exceed the respective field instrument threshold values previously stated andranged from 3,400 to 9,500 cpm unshielded with a maximum of 4,500 cpm shielded in the bottom of theexcavation
Height and weight errors in aeromedical certification data.
DOT National Transportation Integrated Search
1973-06-01
The Framingham Relative Weight Index (FRWI) of obesity was described in previous reports as a screening aid for detecting susceptibility to coronary heart disease (CHD). FRWI calculation requires measured values of height and weight but the height an...
300 East Randolph, December 2010, Lindsay Light Radiological Survey
Field gamma measurements within the excavation and the spoil materials generated during theexcavation process did not exceed the respective threshold values previously stated and generallyranged from 4,050 cpm to 9,690 cpm with the unshielded probe.
362-363 E. Ontario, April 2012, Lindsay Light Radiological Survey
field gamma measurements did not exceed the respective field instrument threshold values previously stated andranged from 3,400 to 9,500 cpm unshielded with a maximum of 4,500 cpm shielded in the bottom of theexcavation.
Sinuosity of Martian rampart ejecta deposits
NASA Technical Reports Server (NTRS)
Barlow, Nadine G.
1994-01-01
The sinuosities of 2213 Martian rampart ejecta craters are quantified through measurement of the ejecta flow front perimeter and ejecta area. This quantity, called lobateness, was computed for each complete lobe of the 1582 single lobe (SL), 251 double lobe (DL), and 380 multiple lobe (ML) craters included in this study. A lobateness value of 1 indicates a circular ejecta blanket, whereas more sinuous ejecta perimeters have lobateness values greater than 1. Although resolution does have an effect on the absolute values of lobateness, the general relationships between lobateness and morphology exist regardless of resolution. Evaluation of the lobateness values reveals that the outer lobes of DL and ML craters have higher median lobateness values (i.e., are more sinuous) than the inner lobes. The outermost lobe of ML craters displays higher lobateness values than the outer lobe of DL craters or the single lobe of SL craters. Previous reports of lobateness-diameter, lobateness-latitude, and lobateness-terrain relationships for rampart craters are not supported by this study. Many of the differences between the results of this study and the previous lobateness analyses can be attributed to the inclusion of resolution effects and the distinction between different ejecta morphologies in this study. The results of this study taken together with a previous analysis of the distribution and diameter dependence of different ejecta morphologies are most consistent with the theory that Martian lobate ejecta morphologies form from impact into subsurface volatiles.
Reexamination of the effective fine structure constant of graphene as measured in graphite
Gan, Yu; de la Pena Munoz, Gilberto; Kogar, Anshul; ...
2016-05-24
Here we present a refined and improved study of the influence of screening on the effective fine structure constant of graphene, α*, as measured in graphite using inelastic x-ray scattering. This followup to our previous study [J. P. Reed et al., Science 330, 805 (2010)] was carried out with two times better energy resolution, five times better momentum resolution, and an improved experimental setup with lower background. We compare our results to random-phase approximation (RPA) calculations and evaluate the relative importance of interlayer hopping, excitonic corrections, and screening from high energy excitations involving the sigma bands. We find that themore » static, limiting value of α* falls in the range 0.25-0.35, which is higher than our previous result of 0.14, but still below the value expected from RPA. We show the reduced value is not a consequence of interlayer hopping effects, which were ignored in our previous analysis, but of a combination of excitonic effects in the π→ π* particle-hole continuum, and background screening from the σ-bonded electrons. We find that σ-band screening is extremely strong at distances of less than a few nanometers, and should be highly effective at screening out short-distance, Hubbard-like interactions in graphene as well as other carbon allotropes.« less
Rotational Velocity Determinations for 118 δ Scuti Variables
NASA Astrophysics Data System (ADS)
Bush, Tabitha C.; Hintz, E. G.
2009-01-01
We present a calibration method used for the determination of projected rotational velocities (vsin i) of 118 δ Scuti variables from FWHM measurements of metal lines near 4500 Å. The calibration relation used was derived from measurements of 29 stars. Of the 44 stars brighter than 8th magnitude and north of -1° declination which did not have values in the Rodríguez catalog (Rodríguez, E., López González, M. J., & López de Coca, P. 2000, A&AS, 144, 469), we present values for 38. In addition, we present new vsin i values for 10 stars south of -1° or fainter than 8th magnitude for a total of 48 vsin i values for stars with no previously published values. We acknowledge the Dominion Astrophysical Observatory for making available the 1.2-m and 1.8-m telescopes to aid in this research.
Urban, M.W.; Fatemi, M.; Greenleaf, J.F.
2011-01-01
This paper reports shear stiffness and viscosity “virtual biopsy” measurements of three excised non-cancerous human prostates using shearwave dispersion ultrasound vibrometry (SDUV) in vitro. Improved methods for prostate guided-biopsy are required to effectively guide needle biopsy to the suspected site. In addition, tissue stiffness measurement helps identifying a suspected site to perform biopsy because stiffness has been shown to correlate with pathology. More importantly, early detection of prostate cancer may guide minimally-invasive therapy and eliminate insidious procedures. In this work, “virtual” biopsies were taken in multiple locations in three excised prostates. Then, SDUV shear elasticity and viscosity measurements have been performed at the selected “suspicious” locations within the prostates. SDUV measurements of prostate elasticity and viscosity are generally in agreement with preliminary values reported previously in the literature. It is however important to emphasize that the obtained viscoelastic parameters values are local, and not a mean value for the whole prostate. PMID:20595086
Torgén, M; Winkel, J; Alfredsson, L; Kilbom, A
1999-06-01
The principal aim of the present study was to evaluate questionnaire-based information on past physical work loads (6-year recall). Effects of memory difficulties on reproducibility were evaluated for 82 subjects by comparing previously reported results on current work loads (test-retest procedure) with the same items recalled 6 years later. Validity was assessed by comparing self-reports in 1995, regarding work loads in 1989, with worksite measurements performed in 1989. Six-year reproducibility, calculated as weighted kappa coefficients (k(w)), varied between 0.36 and 0.86, with the highest values for proportion of the workday spent sitting and for perceived general exertion and the lowest values for trunk and neck flexion. The six-year reproducibility results were similar to previously reported test-retest results for these items; this finding indicates that memory difficulties was a minor problem. The validity of the questionnaire responses, expressed as rank correlations (r(s)) between the questionnaire responses and workplace measurements, varied between -0.16 and 0.78. The highest values were obtained for the items sitting and repetitive work, and the lowest and "unacceptable" values were for head rotation and neck flexion. Misclassification of exposure did not appear to be differential with regard to musculoskeletal symptom status, as judged by the calculated risk estimates. The validity of some of these self-administered questionnaire items appears sufficient for a crude assessment of physical work loads in the past in epidemiologic studies of the general population with predominantly low levels of exposure.
NASA Astrophysics Data System (ADS)
Hill, David T.; Driver, Simon P.; Cameron, Ewan; Cross, Nicholas; Liske, Jochen; Robotham, Aaron
2010-05-01
We combine data from the Millennium Galaxy Catalogue, Sloan Digital Sky Survey and UKIRT Infrared Deep Sky Survey Large Area Survey to produce ugrizYJHK luminosity functions and densities from within a common, low-redshift volume (z < 0.1, ~ 71000h-31 Mpc3 for L* systems) with 100 per cent spectroscopic completeness. In the optical the fitted Schechter functions are comparable in shape to those previously reported values but with higher normalizations (typically 0, 30, 20, 15, 5 per cent higher φ* values in u, g, r, i, z, respectively, over those reported by the SDSS team). We attribute these to differences in the redshift ranges probed, incompleteness and adopted normalization methods. In the near-IR (NIR) we find significantly different Schechter function parameters (mainly in the M* values) to those previously reported and attribute this to the improvement in the quality of the imaging data over previous studies. This is the first homogeneous measurement of the extragalactic luminosity density which fully samples both the optical and NIR regimes. Unlike previous compilations that have noted a discontinuity between the optical and NIR regimes our homogeneous data set shows a smooth cosmic spectral energy distribution (CSED). After correcting for dust attenuation we compare our CSED to the expected values based on recent constraints on the cosmic star formation history and the initial mass function.
NASA Technical Reports Server (NTRS)
Webster, Christopher R.; May, Randy D.
1992-01-01
Simultaneous in situ measurements of stratospheric CH4, (C-13)H4, N2O, OC(O-18), pressure, and temperature have been made from Palestine, Texas (32 deg N) in September 1988 with the JPL Balloon-borne Laser In Situ Sensor. Measurements of CH4 and N2O in the altitude range 30-35 km agree well with other measurements, except for an anomalously high value for the N2O at 31 km. Measurements of CH4 support earlier observations of fold in the vertical profile. A ratio for stratospheric (C-13)H4/CH4 of 0.0105 +/- 0.0010 implies an enrichment of delta(C-13) = -45 +/- 92 parts per thousand over the PDB value, in agreement with previous measurements in the troposphere. A large mixing ratio of 1.9 +/- 0.2 ppmv for OC(O-18) is measured, corresponding to an enrichment of delta(O-18) = 280 +/- 50 parts per thousand for the (O-18) isotopic species over the SMOW value.
NASA Astrophysics Data System (ADS)
Zhao, Ke; Ji, Yaoyao; Pan, Boan; Li, Ting
2018-02-01
The continuous-wave Near-infrared spectroscopy (NIRS) devices have been highlighted for its clinical and health care applications in noninvasive hemodynamic measurements. The baseline shift of the deviation measurement attracts lots of attentions for its clinical importance. Nonetheless current published methods have low reliability or high variability. In this study, we found a perfect polynomial fitting function for baseline removal, using NIRS. Unlike previous studies on baseline correction for near-infrared spectroscopy evaluation of non-hemodynamic particles, we focused on baseline fitting and corresponding correction method for NIRS and found that the polynomial fitting function at 4th order is greater than the function at 2nd order reported in previous research. Through experimental tests of hemodynamic parameters of the solid phantom, we compared the fitting effect between the 4th order polynomial and the 2nd order polynomial, by recording and analyzing the R values and the SSE (the sum of squares due to error) values. The R values of the 4th order polynomial function fitting are all higher than 0.99, which are significantly higher than the corresponding ones of 2nd order, while the SSE values of the 4th order are significantly smaller than the corresponding ones of the 2nd order. By using the high-reliable and low-variable 4th order polynomial fitting function, we are able to remove the baseline online to obtain more accurate NIRS measurements.
Ziegeweid, J.R.; Black, M.C.
2010-01-01
Little is known about the physiological capabilities of young-of-year (YOY) shortnose sturgeon. In this study, plasma osmolality and hematocrit values were measured for YOY shortnose sturgeon following 48-h exposures to 12 different combinations of salinity and temperature. Hematocrit levels varied significantly with temperature and age, and plasma osmolalities varied significantly with salinity and age. Plasma osmolality and hematocrit values were similar to previously published values for other sturgeons of similar age and size in similar treatment conditions. ?? 2010 Springer Science+Business Media B.V.
NASA Astrophysics Data System (ADS)
Başar, Gü.; Güzelçimen, F.; Öztürk, I. K.; Er, A.; Bingöl, D.; Kröger, S.; Başar, Gö.
2017-11-01
The hyperfine structure of 57 spectral lines of neutral vanadium has been investigated using a hollow cathode lamp by laser-induced fluorescence spectroscopy in the wavelength range from 750 nm to 860 nm. New magnetic dipole hyperfine structure constants A have been determined for 14 atomic energy levels and new electric quadrupole hyperfine structure constants B for two levels. Additionally previously published hyperfine structure constants A of 56 levels have been measured again. In five cases, the old A values have been rejected and replaced by improved values.
Measuring Distance of Fuzzy Numbers by Trapezoidal Fuzzy Numbers
NASA Astrophysics Data System (ADS)
Hajjari, Tayebeh
2010-11-01
Fuzzy numbers and more generally linguistic values are approximate assessments, given by experts and accepted by decision-makers when obtaining value that is more accurate is impossible or unnecessary. Distance between two fuzzy numbers plays an important role in linguistic decision-making. It is reasonable to define a fuzzy distance between fuzzy objects. To achieve this aim, the researcher presents a new distance measure for fuzzy numbers by means of improved centroid distance method. The metric properties are also studied. The advantage is the calculation of the proposed method is far simple than previous approaches.
USDA-ARS?s Scientific Manuscript database
Most previous analyses of leaf gas exchange measurements assumed an infinite value of mesophyll conductance (gm) and thus equaled CO2 partial pressures in the substomatal cavity and chloroplast. Yet an increasing number of studies have recognized that gm is finite and there is a drawdown of CO2 part...
240 E Ontario St, September 2011, Lindsay Light Radiological Survey
Unshielded field gamma measurements within theexcavation and the spoil materials generated during the excavation process did not exceed the respectivethreshold values previously stated and ranged from a minimum of 7,500 cpm to a maximum of 8,100 cpm.
151 N. Field Blvd., August 2010, Lindsay Light Radiological Survey
The field gamma measurements within theexcavation and the spoil materials generated during the excavation process did not exceed therespective threshold values previously stated and ranged from a minimum of 2,400 cpm to amaximum of 3,000 cpm.
400 E. Monroe, January 2011, Lindsay Light Radiological Survey
The fieldgamma measurements within the excavation and the spoil materials generated during the excavationprocess did not exceed the respective threshold values previously stated and ranged from a minimum of4,867 cpm to a maximum of 7,351 cpm.
165 E Ontario, October 2010, Lindsay Light Radiological Survey
The field gamma measurements within the excavation and the spoil materials generatedduring the excavation process did not exceed the respective threshold values previously stated andranged from a minimum of 2, 150 cpm to a maximum of 6,270 cpm.
641 N Michigan, September 2011, Lindsay Light Radiological Survey
The unshielded field gamma measurements within the spoil matehals generated during the drilling processdid not exceed the respective threshold values previously stated and ranged from background levels of 4,000cpm to a maximum of about 8,000 cpm.
Compendium of Experimental Cetane Numbers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yanowitz, Janet; Ratcliff, Matthew A.; McCormick, Robert L.
This report is an updated version of the 2014 Compendium of Experimental Cetane Number Data and presents a compilation of measured cetane numbers for pure chemical compounds. It includes all available single-compound cetane number data found in the scientific literature up until December 2016 as well as a number of previously unpublished values, most measured over the past decade at the National Renewable Energy Laboratory. This version of the compendium contains cetane values for 496 pure compounds, including 204 hydrocarbons and 292 oxygenates. 176 individual measurements are new to this version of the compendium, all of them collected using ASTMmore » Method D6890, which utilizes an Ignition Quality Tester (IQT) a type of constant-volume combustion chamber. For many compounds, numerous measurements are included, often collected by different researchers using different methods. The text of this document is unchanged from the 2014 version, except for the numbers of compounds in Section 3.1, the Appendices, Table 1. Primary Cetane Number Data Sources and Table 2. Number of Measurements Included in Compendium. Cetane number is a relative ranking of a fuel's autoignition characteristics for use in compression ignition engines. It is based on the amount of time between fuel injection and ignition, also known as ignition delay. The cetane number is typically measured either in a single-cylinder engine or a constant-volume combustion chamber. Values in the previous compendium derived from octane numbers have been removed and replaced with a brief analysis of the correlation between cetane numbers and octane numbers. The discussion on the accuracy and precision of the most commonly used methods for measuring cetane number has been expanded, and the data have been annotated extensively to provide additional information that will help the reader judge the relative reliability of individual results.« less
Developing the Precision Magnetic Field for the E989 Muon g{2 Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Matthias W.
The experimental value ofmore » $$(g\\hbox{--}2)_\\mu$$ historically has been and contemporarily remains an important probe into the Standard Model and proposed extensions. Previous measurements of $$(g\\hbox{--}2)_\\mu$$ exhibit a persistent statistical tension with calculations using the Standard Model implying that the theory may be incomplete and constraining possible extensions. The Fermilab Muon g-2 experiment, E989, endeavors to increase the precision over previous experiments by a factor of four and probe more deeply into the tension with the Standard Model. The $$(g\\hbox{--}2)_\\mu$$ experimental implementation measures two spin precession frequencies defined by the magnetic field, proton precession and muon precession. The value of $$(g\\hbox{--}2)_\\mu$$ is derived from a relationship between the two frequencies. The precision of magnetic field measurements and the overall magnetic field uniformity achieved over the muon storage volume are then two undeniably important aspects of the e xperiment in minimizing uncertainty. The current thesis details the methods employed to achieve magnetic field goals and results of the effort.« less
Vortex wakes generated by robins Erithacus rubecula during free flight in a wind tunnel.
Hedenström, A; Rosén, M; Spedding, G R
2006-04-22
The wakes of two individual robins were measured in digital particle image velocimetry (DPIV) experiments conducted in the Lund wind tunnel. Wake measurements were compared with each other, and with previous studies in the same facility. There was no significant individual variation in any of the measured quantities. Qualitatively, the wake structure and its gradual variation with flight speed were exactly as previously measured for the thrush nightingale. A procedure that accounts for the disparate sources of circulation spread over the complex wake structure nevertheless can account for the vertical momentum flux required to support the weight, and an example calculation is given for estimating drag from the components of horizontal momentum flux (whose net value is zero). The measured circulations of the largest structures in the wake can be predicted quite well by simple models, and expressions are given to predict these and other measurable quantities in future bird flight experiments.
Mediterranean Environmental Acoustic Data Catalog
1975-05-01
kH.z. (C) SACLANT ASW Centre returned to the Tyrrhenian Sea to an area previously reported by Hastrup and Lallement to conduct extended tests uhich...were reported in 1962 by Hastrup . In these tests both explosive charges and an AN/SQS-26 sonar were used as sources, with a shallow suspended hydrophone...bottom at the point of reflection. The measured bottom reflection loss values in these tests agreed with the previously reported tests ( Hastrup and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanchez, R.; Zakova, Monika; Andejelkovic, Zoran
The frequencies of the 2S–3S two-photon transition for the stable lithium isotopes were measured by cavity-enhanced Doppler-free laser excitation that was controlled by a femtosecond frequency comb. The resulting values of 815 618 181.57(18) and 815 606 727.59(18) MHz, respectively, for 7Li and 6Li are in agreement with previous measurements but are more accurate by an order of magnitude. There is still a discrepancy of about 11.6 and 10.6MHz from the latest theoretical values. This is comparable to the uncertainty in the theoretical calculations, while uncertainty in our experimental values is more than a hundred-fold smaller. More accurate theoretical calculationmore » of the transition frequencies would allow extraction of the absolute charge radii for these stable isotopes, which in turn could improve nuclear charge radii values for the unstable lithium isotopes.« less
Accuracy and precision of as-received implant torque wrenches.
Britton-Vidal, Eduardo; Baker, Philip; Mettenburg, Donald; Pannu, Darshanjit S; Looney, Stephen W; Londono, Jimmy; Rueggeberg, Frederick A
2014-10-01
Previous implant torque evaluation did not determine if the target value fell within a confidence interval for the population mean of the test groups, disallowing determination of whether a specific type of wrench met a standardized goal value. The purpose of this study was to measure both the accuracy and precision of 2 different configurations (spring style and peak break) of as-received implant torque wrenches and compare the measured values to manufacturer-stated values. Ten wrenches from 4 manufacturers, representing a variety of torque-limiting mechanisms and specificity of use (with either a specific brand or universally with any brand of implant product). Drivers were placed into the wrench, and tightening torque was applied to reach predetermined values using a NIST-calibrated digital torque wrench. Five replications of measurement were made for each wrench and averaged to provide a single value from that instrument. The target torque value for each wrench brand was compared to the 95% confidence interval for the true population mean of measured values to see if it fell within the measured range. Only 1 wrench brand (Nobel Biocare) demonstrated the target torque value falling within the 95% confidence interval for the true population mean. For others, the targeted torque value fell above the 95% confidence interval (Straumann and Imtec) or below (Salvin Torq). Neither type of torque-limiting mechanism nor designation of a wrench to be used as a dedicated brand-only product or to be used as a universal product on many brands affected the ability of a wrench to deliver torque values where the true population mean included the target torque level. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Actinometric measurement of j(O3-O(1D)) using a luminol detector
NASA Technical Reports Server (NTRS)
Bairai, Solomon T.; Stedman, Donald H.
1992-01-01
The photolysis frequency of ozone to singlet D oxygen atoms has been measured by means of a chemical actinometer using a luminol based detector. The instrument measures j(O3-O(1D)) with a precision of 10 percent. The data collected in winter and spring of 1991 is in agreement with model predictions and previously measured values. Data from a global solar radiometer can be used to estimate the effects of local cloudiness on j(O3-O(1D)).
Zarzana, Kyle J; Min, Kyung-Eun; Washenfelder, Rebecca A; Kaiser, Jennifer; Krawiec-Thayer, Mitchell; Peischl, Jeff; Neuman, J Andrew; Nowak, John B; Wagner, Nicholas L; Dubè, William P; St Clair, Jason M; Wolfe, Glenn M; Hanisco, Thomas F; Keutsch, Frank N; Ryerson, Thomas B; Brown, Steven S
2017-10-17
We report enhancements of glyoxal and methylglyoxal relative to carbon monoxide and formaldehyde in agricultural biomass burning plumes intercepted by the NOAA WP-3D aircraft during the 2013 Southeast Nexus and 2015 Shale Oil and Natural Gas Nexus campaigns. Glyoxal and methylglyoxal were measured using broadband cavity enhanced spectroscopy, which for glyoxal provides a highly selective and sensitive measurement. While enhancement ratios of other species such as methane and formaldehyde were consistent with previous measurements, glyoxal enhancements relative to carbon monoxide averaged 0.0016 ± 0.0009, a factor of 4 lower than values used in global models. Glyoxal enhancements relative to formaldehyde were 30 times lower than previously reported, averaging 0.038 ± 0.02. Several glyoxal loss processes such as photolysis, reactions with hydroxyl radicals, and aerosol uptake were found to be insufficient to explain the lower measured values of glyoxal relative to other biomass burning trace gases, indicating that glyoxal emissions from agricultural biomass burning may be significantly overestimated. Methylglyoxal enhancements were three to six times higher than reported in other recent studies, but spectral interferences from other substituted dicarbyonyls introduce an estimated correction factor of 2 and at least a 25% uncertainty, such that accurate measurements of the enhancements are difficult.
NASA Astrophysics Data System (ADS)
Kloog, Itai; Koutrakis, Petros; Coull, Brent A.; Lee, Hyung Joo; Schwartz, Joel
2011-11-01
Land use regression (LUR) models provide good estimates of spatially resolved long-term exposures, but are poor at capturing short term exposures. Satellite-derived Aerosol Optical Depth (AOD) measurements have the potential to provide spatio-temporally resolved predictions of both long and short term exposures, but previous studies have generally showed relatively low predictive power. Our objective was to extend our previous work on day-specific calibrations of AOD data using ground PM 2.5 measurements by incorporating commonly used LUR variables and meteorological variables, thus benefiting from both the spatial resolution from the LUR models and the spatio-temporal resolution from the satellite models. Later we use spatial smoothing to predict PM 2.5 concentrations for day/locations with missing AOD measures. We used mixed models with random slopes for day to calibrate AOD data for 2000-2008 across New-England with monitored PM 2.5 measurements. We then used a generalized additive mixed model with spatial smoothing to estimate PM 2.5 in location-day pairs with missing AOD, using regional measured PM 2.5, AOD values in neighboring cells, and land use. Finally, local (100 m) land use terms were used to model the difference between grid cell prediction and monitored value to capture very local traffic particles. Out-of-sample ten-fold cross-validation was used to quantify the accuracy of our predictions. For days with available AOD data we found high out-of-sample R2 (mean out-of-sample R2 = 0.830, year to year variation 0.725-0.904). For days without AOD values, our model performance was also excellent (mean out-of-sample R2 = 0.810, year to year variation 0.692-0.887). Importantly, these R2 are for daily, rather than monthly or yearly, values. Our model allows one to assess short term and long-term human exposures in order to investigate both the acute and chronic effects of ambient particles, respectively.
Chow, Angela; Eccles, Jacquelynne S; Salmela-Aro, Katariina
2012-11-01
Two independent studies were conducted to extend previous research by examining the associations between task value priority patterns across school subjects and aspirations toward the physical and information technology- (IT-) related sciences. Study 1 measured task values of a sample of 10th graders in the United States (N = 249) across (a) physics and chemistry, (b) math, and (c) English. Study 2 measured task values of a sample of students in the second year of high school in Finland (N = 351) across (a) math and science, (b) Finnish, and (c) the arts and physical education. In both studies, students were classified into groups according to how they ranked math and science in relation to the other subjects. Regression analyses indicated that task value group membership significantly predicted subsequent aspirations toward physical and IT-related sciences measured 1-2 years later. The task value groups who placed the highest priority on math and science were significantly more likely to aspire to physical and IT-related sciences than were the other groups. These findings provide support for the theoretical assumption regarding the predictive role of intraindividual hierarchical patterns of task values for subsequent preferences and choices suggested by the Eccles [Parsons] (1983) expectancy-value model.
200 E Illinois St, December 2011, Lindsay Light Radiological Survey
Field gamma measurements within the excavation and the spoil materials generated during the excavation process did not exceed the respective threshold value previously stated and ranged from a minimum of 7,100 cpm to amaximum of 9,400 cpm unshielded.
158 East Ontario, July 23, 2013, Lindsay Light Radiological Survey
Field gamma measurements within the excavation and the spoil materials generated during the excavationprocess did not exceed the respective threshold values previously stated and ranged from a minimum of6,700 cpm to a maximum of 8,700 cpm unshielded.
600-602 N Lakeshore Drive, March 2011, Lindsay Light Radiological Survey
The fieldgamma measurements within the excavation and the spoil materials generated during the excavationprocess did not exceed the respective threshold values previously stated and ranged from a minimum of4,382 cpm to a maximum of 7,907 cpm.
Lindsay Light Radiological Survey 350 E Ohio St, May 2013
Field gamma measurements within the excavation and the spoil materials generated during the excavationprocess did not exceed the respective threshold values previously stated and ranged from a minimum of5,700 cpm to a maximum of 12,200 cpm unshielded.
201 E South Water, December 2010, Lindsay Light Radiological Survey
The field gamma measurements within the excavation and the spoil materials generated during the excavation process did not exceed the respective threshold values previously stated and ranged from a minimum of7,234 cpm to a maximum of 9,872 cpm.
Ten years of measured UV Index from the Spanish UVB Radiometric Network.
Utrillas, M P; Marín, M J; Esteve, A R; Estellés, V; Gandía, S; Núnez, J A; Martínez-Lozano, J A
2013-08-05
An analysis is made of the UV Index (UVI) obtained from the ultraviolet erythemal solar radiation (UVER) data measured by the Spanish UVB Radiometric Network between the years 2000 and 2009. Previously, the daily UVI has been evaluated using two different criteria: (a) the value corresponding to solar noon; and (b) the daily maximum value. The mean percentage of agreement is 92% if we consider the cases for which the difference is zero or one UVI unit. These results are similar to those obtained in a previous work where only 2 years were analyzed. In all the stations the UVI reaches very high values (8-10) in spring-summer, and the very high and extreme (≥ 11) UVI values are more dependent on the continental effect than on the latitude effect. From the UVI values it is possible to classify the stations into four groups: Coastal stations, Continental stations (more than 200 km from the coast), Southern stations (Coastal stations but with similar values of UVI as the Continental ones due to their low latitude) and Canary Islands stations (1400 km southwest from the Iberian Peninsula thus lower latitude). The monthly mean maximum of UVI is reached in July due to the annual evolution of the total ozone column. This value corresponds, for a skin phototype II, to three times the minimal erythemal dose (MED) in an hour in a Coastal station, 3.5 MEDs in an hour measured in a Continental or Southern station and up five MEDs in an hour in the Izaña station (Canary Islands). The cumulative dose on a horizontal plane over an average year has been calculated for each station. More than 40% of the annual dose is received in summer, about 35% in spring, more than 11% in autumn and less than 10% in winter except for the stations in the Canary Islands where the difference between seasons is less significant. Copyright © 2013 Elsevier B.V. All rights reserved.
Water Vapor Winds and Their Application to Climate Change Studies
NASA Technical Reports Server (NTRS)
Jedlovec, Gary J.; Lerner, Jeffrey A.
2000-01-01
The retrieval of satellite-derived winds and moisture from geostationary water vapor imagery has matured to the point where it may be applied to better understanding longer term climate changes that were previously not possible using conventional measurements or model analysis in data-sparse regions. In this paper, upper-tropospheric circulation features and moisture transport covering ENSO periods are presented and discussed. Precursors and other detectable interannual climate change signals are analyzed and compared to model diagnosed features. Estimates of winds and humidity over data-rich regions are used to show the robustness of the data and its value over regions that have previously eluded measurement.
Papuga, M Owen; Burke, Jeanmarie R
2011-02-01
An ink pad and paper, pressure-sensitive platforms, and photography have previously been used to collect footprint data used in clinical assessment. Digital scanners have been widely used more recently to collect such data. The purpose of this study was to evaluate the intra- and interrater reliability of a flatbed digital image scanning technology to capture footprint data. This study used a repeated-measures design on 32 (16 male 16 female) healthy subjects. The following measured indices of footprint were recorded from 2-dimensional images of the plantar surface of the foot recorded with an Associate Platinum (Foot Levelers Inc, Roanoke, VA) digital foot scanner: Staheli index, Chippaux-Smirak index, arch angle, and arch index. Intraclass correlation coefficient (ICC) values were calculated to evaluate intrarater, interday, and interclinician reliability. The ICC values for intrarater reliability were greater than or equal to .817, indicating an excellent level of reproducibility in assessing the collected images. Analyses of variance revealed that there were no significant differences between raters for each index (P > .05). The ICC values also indicated excellent reliability (.881-.971) between days and clinicians in all but one of the indices of footprint, arch angle (.689), with good reliability between clinicians. The full-factorial analysis of variance model did not reveal any interaction effects (P > .05), which indicated that indices of footprint were not changing across days and clinicians. Scanning technology used in this study demonstrated good intra- and interrater reliability measurements of footprint indices, as demonstrated by high ICC values. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Giuliani, S; Patacchini, R; Barbanti, G; Turini, D; Rovero, P; Quartara, L; Giachetti, A; Maggi, C A
1993-11-01
The tachykinin (NK2) receptor-mediating contraction of the human isolated bladder to NKA was investigated by studying the affinities of eight structurally different receptor-selective antagonists (linear peptides, cyclic peptides and pseudopeptides, nonpeptide NK2 receptor antagonists). The affinities of the antagonists were compared to those measured for the same ligands at the NK2 receptors previously characterized in the rabbit pulmonary artery and hamster trachea. In the presence of a cocktail of peptidase inhibitors (bestatin captopril and thiorphan, 1 microM each) no significant correlation was found between pA2 values measured in the human bladder vs. those measured in the other two NK2 receptor-bearing preparation. In the presence of the aminopeptidase inhibitor amastatin, however, pA2 values of linear antagonists bearing an N-terminal Asp residue MEN 10,207 and MEN 10,376 were significantly enhanced and these pA2 values were used for analysis; a significant correlation was found between pA2 values measured in the human urinary bladder and rabbit pulmonary artery. The pseudopeptide analog of NKA (4-10), MDL 28,564 which also bears a N-terminal Asp residue behaved as an agonist and its action was enhanced by amastatin. We conclude that the NK2 receptor-mediating contraction of the human urinary bladder smooth muscle is similar to that previously characterized in the rabbit pulmonary artery (NK2A receptor category); in the human bladder smooth muscle an amastatin-sensitive peptidase (possibly aminopeptidase A) limits biological activity of linear peptide derivatives of NKA bearing a N-terminal Asp residue.
NASA Astrophysics Data System (ADS)
Arita, Yuji; Suzuki, Keisuke; Matsui, Tsuneo
2005-02-01
The temperature limit for heat capacity measurements with the direct heating pulse calorimeter has been increased up to 2000 K by means of the combination of an optical pyrometer to detect the relative temperature change with tungsten rhenium thermocouples to determine absolute temperatures. With this improved calorimeter the heat capacities were measured up to 1950 K, for SiC and B4C, and 2000 K for graphite. The heat capacity values obtained in this study were in good agreement, within the error of ±5%, with those previous values calculated from the enthalpy data by drop method. The electrical conductivities of SiC, B4C and graphite were also simultaneously determined from the inducted voltage and the current for heat capacity measurement.
High-Precision Half-Life and Branching Ratio Measurements for the Superallowed β+ Emitter 26Alm
NASA Astrophysics Data System (ADS)
Finlay, P.; Svensson, C. E.; Demand, G. A.; Garrett, P. E.; Green, K. L.; Leach, K. G.; Phillips, A. A.; Rand, E. T.; Ball, G.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Grinyer, G. F.; Sumithrarachchi, C. S.; Williams, S. J.; Triambak, S.
2013-03-01
High-precision half-life and branching-ratio measurements for the superallowed β+ emitter 26Alm were performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ≤ 15 ppm at 90% C.L. was determined for the sum of all possible non-analogue β+/EC decay branches of 26Alm, yielding a superallowed branching ratio of 100.0000+0-0.0015%. A value of T1/2 = 6:34654(76) s was determined for the 26Alm half-life which is consistent with, but 2.5 times more precise than, the previous world average. Combining these results with world-average measurements yields an ft value of 3037.58(60) s, the most precisely determined for any superallowed emitting nucleus to date. This high-precision ft value for 26Alm provides a new benchmark to refine theoretical models of isospin-symmetry-breaking effects in superallowed β decays.
NASA Astrophysics Data System (ADS)
Aghasyan, M.; Alexeev, M. G.; Alexeev, G. D.; Amoroso, A.; Andrieux, V.; Anfimov, N. V.; Anosov, V.; Antoshkin, A.; Augsten, K.; Augustyniak, W.; Austregesilo, A.; Azevedo, C. D. R.; Badełek, B.; Balestra, F.; Ball, M.; Barth, J.; Beck, R.; Bedfer, Y.; Bernhard, J.; Bicker, K.; Bielert, E. R.; Birsa, R.; Bodlak, M.; Bordalo, P.; Bradamante, F.; Bressan, A.; Büchele, M.; Burtsev, V. E.; Capozza, L.; Chang, W.-C.; Chatterjee, C.; Chiosso, M.; Choi, I.; Chumakov, A. G.; Chung, S.-U.; Cicuttin, A.; Crespo, M. L.; Dalla Torre, S.; Dasgupta, S. S.; Dasgupta, S.; Denisov, O. Yu.; Dhara, L.; Donskov, S. V.; Doshita, N.; Dreisbach, Ch.; Dünnweber, W.; Dusaev, R. R.; Dziewiecki, M.; Efremov, A.; Eversheim, P. D.; Faessler, M.; Ferrero, A.; Finger, M.; Finger, M.; Fischer, H.; Franco, C.; Du Fresne von Hohenesche, N.; Friedrich, J. M.; Frolov, V.; Fuchey, E.; Gautheron, F.; Gavrichtchouk, O. P.; Gerassimov, S.; Giarra, J.; Giordano, F.; Gnesi, I.; Gorzellik, M.; Grasso, A.; Gridin, A.; Grosse Perdekamp, M.; Grube, B.; Grussenmeyer, T.; Guskov, A.; Hahne, D.; Hamar, G.; von Harrach, D.; Heinsius, F. H.; Heitz, R.; Herrmann, F.; Horikawa, N.; D'Hose, N.; Hsieh, C.-Y.; Huber, S.; Ishimoto, S.; Ivanov, A.; Iwata, T.; Jary, V.; Joosten, R.; Jörg, P.; Kabuß, E.; Kerbizi, A.; Ketzer, B.; Khaustov, G. V.; Khokhlov, Yu. A.; Kisselev, Yu.; Klein, F.; Koivuniemi, J. H.; Kolosov, V. N.; Kondo, K.; Königsmann, K.; Konorov, I.; Konstantinov, V. F.; Kotzinian, A. M.; Kouznetsov, O. M.; Kral, Z.; Krämer, M.; Kremser, P.; Krinner, F.; Kroumchtein, Z. V.; Kulinich, Y.; Kunne, F.; Kurek, K.; Kurjata, R. P.; Kuznetsov, I. I.; Kveton, A.; Lednev, A. A.; Levchenko, E. A.; Levillain, M.; Levorato, S.; Lian, Y.-S.; Lichtenstadt, J.; Longo, R.; Lyubovitskij, V. E.; Maggiora, A.; Magnon, A.; Makins, N.; Makke, N.; Mallot, G. K.; Mamon, S. A.; Marianski, B.; Martin, A.; Marzec, J.; Matoušek, J.; Matsuda, H.; Matsuda, T.; Meshcheryakov, G. V.; Meyer, M.; Meyer, W.; Mikhailov, Yu. V.; Mikhasenko, M.; Mitrofanov, E.; Mitrofanov, N.; Miyachi, Y.; Moretti, A.; Nagaytsev, A.; Nerling, F.; Neyret, D.; Nový, J.; Nowak, W.-D.; Nukazuka, G.; Nunes, A. S.; Olshevsky, A. G.; Orlov, I.; Ostrick, M.; Panzieri, D.; Parsamyan, B.; Paul, S.; Peng, J.-C.; Pereira, F.; Pešek, M.; Pešková, M.; Peshekhonov, D. V.; Pierre, N.; Platchkov, S.; Pochodzalla, J.; Polyakov, V. A.; Pretz, J.; Quaresma, M.; Quintans, C.; Ramos, S.; Regali, C.; Reicherz, G.; Riedl, C.; Rogacheva, N. S.; Ryabchikov, D. I.; Rybnikov, A.; Rychter, A.; Salac, R.; Samoylenko, V. D.; Sandacz, A.; Santos, C.; Sarkar, S.; Savin, I. A.; Sawada, T.; Sbrizzai, G.; Schiavon, P.; Schmidt, K.; Schmieden, H.; Schönning, K.; Seder, E.; Selyunin, A.; Silva, L.; Sinha, L.; Sirtl, S.; Slunecka, M.; Smolik, J.; Srnka, A.; Steffen, D.; Stolarski, M.; Subrt, O.; Sulc, M.; Suzuki, H.; Szabelski, A.; Szameitat, T.; Sznajder, P.; Tasevsky, M.; Tessaro, S.; Tessarotto, F.; Thiel, A.; Tomsa, J.; Tosello, F.; Tskhay, V.; Uhl, S.; Vasilishin, B. I.; Vauth, A.; Veloso, J.; Vidon, A.; Virius, M.; Wallner, S.; Weisrock, T.; Wilfert, M.; Windmolders, R.; Ter Wolbeek, J.; Zaremba, K.; Zavada, P.; Zavertyaev, M.; Zemlyanichkina, E.; Ziembicki, M.; Compass Collaboration
2018-06-01
We present a precise measurement of the proton longitudinal double-spin asymmetry A1p and the proton spin-dependent structure function g1p at photon virtualities 0.006(GeV / c) 2
NASA Astrophysics Data System (ADS)
Obayashi, Takeshi; Kinoshita, Kengo
2013-01-01
Gene coexpression analysis is a powerful approach to elucidate gene function. We have established and developed this approach using vast amount of publicly available gene expression data measured by microarray techniques. The coexpressed genes are used to estimate gene function of the guide gene or to construct gene coexpression networks. In the case to construct gene networks, researchers should introduce an arbitrary threshold of gene coexpression, because gene coexpression value is continuous value. In the viewpoint to introduce common threshold of gene coexpression, we previously reported rank of Pearson's correlation coefficient (PCC) is more useful than the original PCC value. In this manuscript, we re-assessed the measure of gene coexpression to construct gene coexpression network, and found that mutual rank (MR) of PCC showed better performance than rank of PCC and the original PCC in low false positive rate.
Nuclear DNA C‐values in 30 Species Double the Familial Representation in Pteridophytes
OBERMAYER, RENATE; LEITCH, ILIA J.; HANSON, LYNDA; BENNETT, MICHAEL D.
2002-01-01
Nuclear DNA C‐values and genome size are important biodiversity characters with fundamental biological significance. Yet C‐value data for pteridophytes, a diverse group of vascular plants with approx. 9000 extant species, remain scarce. A recent survey by Bennett and Leitch (2001, Annals of Botany 87: 335–345) found that C‐values were reported for only 48 pteridophyte species. To improve phylogenetic representation in this group and to check previously reported estimates, C‐values for 30 taxa in 17 families were measured using flow cytometry for all but one species. This technique proved generally applicable, but the ease with which C‐value data were generated varied greatly between materials. Comparing the new data with those previously published revealed several large discrepancies. After discounting doubtful data, C‐values for 62 pteridophyte species remained acceptable for analysis. The present work has increased the number of such species’ C‐values by 93 %, and more than doubled the number of families represented (from 10 to 21). Analysis shows that pteridophyte C‐values vary approx. 450‐fold, from 0·16 pg in Selaginella kraussiana to 72·7 pg in Psilotum nudum var. gasa. Superimposing C‐value data onto a robust phylogeny of pteridophytes suggests some possible trends in C‐value evolution and highlights areas for future work. PMID:12197518
Field estimates of body drag coefficient on the basis of dives in passerine birds.
Hedenström, A; Liechti, F
2001-03-01
During forward flight, a bird's body generates drag that tends to decelerate its speed. By flapping its wings, or by converting potential energy into work if gliding, the bird produces both lift and thrust to balance the pull of gravity and drag. In flight mechanics, a dimensionless number, the body drag coefficient (C(D,par)), describes the magnitude of the drag caused by the body. The drag coefficient depends on the shape (or streamlining), the surface texture of the body and the Reynolds number. It is an important variable when using flight mechanical models to estimate the potential migratory flight range and characteristic flight speeds of birds. Previous wind tunnel measurements on dead, frozen bird bodies indicated that C(D,par) is 0.4 for small birds, while large birds should have lower values of approximately 0.2. More recent studies of a few birds flying in a wind tunnel suggested that previous values probably overestimated C(D,par). We measured maximum dive speeds of passerine birds during the spring migration across the western Mediterranean. When the birds reach their top speed, the pull of gravity should balance the drag of the body (and wings), giving us an opportunity to estimate C(D,par). Our results indicate that C(D,par) decreases with increasing Reynolds number within the range 0.17-0.77, with a mean C(D,par) of 0.37 for small passerines. A somewhat lower mean value could not be excluded because diving birds may control their speed below the theoretical maximum. Our measurements therefore support the notion that 0.4 (the 'old' default value) is a realistic value of C(D,par) for small passerines.
Lee, Sang Hoon; Kim, Seung Up; Jang, Jeong Won; Bae, Si Hyun; Lee, Sanghun; Kim, Beom Kyung; Park, Jun Yong; Kim, Do Young; Ahn, Sang Hoon; Han, Kwang–Hyub
2015-01-01
Background/purpose Liver stiffness (LS) measurement using transient elastography can accurately assess the degree of liver fibrosis, which is associated with the risk of the development of hepatocellular carcinoma (HCC). We investigated whether LS values could predict HCC de novo recurrence after radiofrequency ablation (RFA). Methods This retrospective, multicenter study analyzed 111 patients with HCC who underwent RFA and LS measurement using transient elastography between May 2005 and April 2011. All patients were followed until March 2013 to monitor for HCC recurrence. Results This study included 76 men and 35 women with a mean age of 62.4 years, and the mean LS value was 21.2 kPa. During the follow-up period (median 22.4 months), 47 (42.3%) patients experienced HCC de novo recurrence, and 18 (16.2%) died. Patients with recurrence had significantly more frequent liver cirrhosis, more frequent history of previous treatment for HCC, higher total bilirubin, larger spleen size, larger total tumor size, higher tumor number, higher LS values, and lower platelet counts than those without recurrence (all P<0.05). On multivariate analysis, together with previous anti-HCC treatment history, patients with LS values >13.0 kPa were at significantly greater risk for recurrence after RFA, with a hazard ratio (HR) of 3.115 (95% confidence interval [CI], 1.238–7.842, P<0.05). Moreover, LS values independently predicted the mortality after RFA, with a HR of 9.834 (95% CI, 1.148–84.211, P<0.05), together with total bilirubin. Conclusions Our data suggest that LS measurement is a useful predictor of HCC de novo recurrence and overall survival after RFA. PMID:25678801
Lee, Sang Hoon; Kim, Seung Up; Jang, Jeong Won; Bae, Si Hyun; Lee, Sanghun; Kim, Beom Kyung; Park, Jun Yong; Kim, Do Young; Ahn, Sang Hoon; Han, Kwang-Hyub
2015-01-01
Liver stiffness (LS) measurement using transient elastography can accurately assess the degree of liver fibrosis, which is associated with the risk of the development of hepatocellular carcinoma (HCC). We investigated whether LS values could predict HCC de novo recurrence after radiofrequency ablation (RFA). This retrospective, multicenter study analyzed 111 patients with HCC who underwent RFA and LS measurement using transient elastography between May 2005 and April 2011. All patients were followed until March 2013 to monitor for HCC recurrence. This study included 76 men and 35 women with a mean age of 62.4 years, and the mean LS value was 21.2 kPa. During the follow-up period (median 22.4 months), 47 (42.3%) patients experienced HCC de novo recurrence, and 18 (16.2%) died. Patients with recurrence had significantly more frequent liver cirrhosis, more frequent history of previous treatment for HCC, higher total bilirubin, larger spleen size, larger total tumor size, higher tumor number, higher LS values, and lower platelet counts than those without recurrence (all P<0.05). On multivariate analysis, together with previous anti-HCC treatment history, patients with LS values >13.0 kPa were at significantly greater risk for recurrence after RFA, with a hazard ratio (HR) of 3.115 (95% confidence interval [CI], 1.238-7.842, P<0.05). Moreover, LS values independently predicted the mortality after RFA, with a HR of 9.834 (95% CI, 1.148-84.211, P<0.05), together with total bilirubin. Our data suggest that LS measurement is a useful predictor of HCC de novo recurrence and overall survival after RFA.
A fully automated system for quantification of background parenchymal enhancement in breast DCE-MRI
NASA Astrophysics Data System (ADS)
Ufuk Dalmiş, Mehmet; Gubern-Mérida, Albert; Borelli, Cristina; Vreemann, Suzan; Mann, Ritse M.; Karssemeijer, Nico
2016-03-01
Background parenchymal enhancement (BPE) observed in breast dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been identified as an important biomarker associated with risk for developing breast cancer. In this study, we present a fully automated framework for quantification of BPE. We initially segmented fibroglandular tissue (FGT) of the breasts using an improved version of an existing method. Subsequently, we computed BPEabs (volume of the enhancing tissue), BPErf (BPEabs divided by FGT volume) and BPErb (BPEabs divided by breast volume), using different relative enhancement threshold values between 1% and 100%. To evaluate and compare the previous and improved FGT segmentation methods, we used 20 breast DCE-MRI scans and we computed Dice similarity coefficient (DSC) values with respect to manual segmentations. For evaluation of the BPE quantification, we used a dataset of 95 breast DCE-MRI scans. Two radiologists, in individual reading sessions, visually analyzed the dataset and categorized each breast into minimal, mild, moderate and marked BPE. To measure the correlation between automated BPE values to the radiologists' assessments, we converted these values into ordinal categories and we used Spearman's rho as a measure of correlation. According to our results, the new segmentation method obtained an average DSC of 0.81 0.09, which was significantly higher (p<0.001) compared to the previous method (0.76 0.10). The highest correlation values between automated BPE categories and radiologists' assessments were obtained with the BPErf measurement (r=0.55, r=0.49, p<0.001 for both), while the correlation between the scores given by the two radiologists was 0.82 (p<0.001). The presented framework can be used to systematically investigate the correlation between BPE and risk in large screening cohorts.
Keelan, Jeffrey A.; Mattes, Eugen; Tan, HaiWei; Dinan, Andrew; Newnham, John P.; Whitehouse, Andrew J. O.; Jacoby, Peter; Hickey, Martha
2012-01-01
The aim of this study was to measure umbilical blood androgen concentrations in a birth cohort using a highly specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay and assesses the effects of sex, labor, and gestational age on fetal androgen levels at birth. We performed a prospective cohort study of androgen concentrations in mixed arterial and venous umbilical cord serum from 803 unselected singleton pregnancies from a general obstetric population in Western Australia. Total testosterone (TT), Δ4-androstenedione, and dehydroepiandrosterone were extracted from archived cord serum samples and measured using LC-MS/MS. SHBG was measured by ELISA; free testosterone (FT) and bioavailable testosterone (BioT) values were also calculated. Median values for all three androgens were generally lower than previously published values. Levels of TT, FT, BioT, and SHBG were significantly higher in male verses female neonates (P<0.0001), while dehydroepiandrosterone levels were higher in females (P<0.0001). Labor was associated with a significant (∼15–26%) decrease in median cord blood TT and FT levels (both sexes combined), but a modest (∼16–31%) increase in SHBG, Δ4-androstenedione, and dehydroepiandrosterone concentrations. TT and FT were significantly negatively correlated with gestational age at delivery, while SHBG, Δ4-androstenedione, and dehydroepiandrosterone were positively correlated. Antenatal glucocorticoid administration also had a significant effect in the multiple regression models. This is the first study to report umbilical cord androgen levels in a large unselected population of neonates using LC-MS/MS. Our findings suggest that previous studies have over-estimated cord androgen levels, and that fetal, maternal, and obstetric factors influence cord androgen levels differentially. Caution should be exercised when interpreting previously-published data that have not taken all of these factors into account. PMID:22916165
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savard, G.; Department of Physics, University of Chicago, Chicago, Illinois 60637; Buchinger, F.
2005-09-02
The masses of the radioactive nuclei {sup 46}V and its decay daughter {sup 46}Ti have been measured with the Canadian Penning Trap on-line Penning trap mass spectrometer to a precision of 1x10{sup -8}. A Q{sub EC} value of 7052.90(40) keV for the superallowed beta decay of {sup 46}V is obtained from the difference of these two masses. With this precise Q value, the Ft value for this decay is determined with improved precision. An investigation of an earlier Q-value measurement for {sup 46}V uncovers a set of 7 measurements that cannot be reconciled with modern data and affects previous evaluationsmore » of V{sub ud} from superallowed Fermi decays. A new evaluation, adding our new data and removing the discredited subset, yields new values for G{sub V} and V{sub ud}. When combined with recent results for V{sub us}, this yields modified constraints for the unitarity of the Cabibbo-Kobayashi-Maskawa matrix and other extensions of the standard model.« less
NASA Astrophysics Data System (ADS)
Moosmüller, H.; Arnott, W. P.; Rogers, C. F.; Chow, J. C.; Frazier, C. A.; Sherman, L. E.; Dietrich, D. L.
1998-11-01
A new photoacoustic instrument for the measurement of aerosol light absorption was collocated with conventional aerosol instrumentation during the 1996-1997 winter intensive monitoring period of the Northern Front Range Air Quality Study. Measurements of the light absorption efficiency for black carbon were 5 m2/g at 685 nm and 10 m2/g at 532 nm, and for elemental carbon, they were 3.6 m2/g at 685 nm. We show that these values together with previous photoacoustic measurements of aerosol light absorption shed some light on the wavelength dependence of absorption efficiency for carbonaceous aerosol in the visible and near-visible region. Integrating plate type filter measurements of aerosol light absorption result in far larger values than those measured with the photoacoustic instrument. We demonstrate that a recently published correction technique [Horvath, 1997] can yield improved agreement.
The Muon $g$-$2$ Experiment at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gohn, Wesley
A new measurement of the anomalous magnetic moment of the muon,more » $$a_{\\mu} \\equiv (g-2)/2$$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at Brookhaven National Laboratory (BNL) and completed in 2001, shows a 3.5 standard deviation discrepancy with the standard model value of $$a_\\mu$$. The new measurement will accumulate 21 times the BNL statistics using upgraded magnet, detector, and storage ring systems, enabling a measurement of $$a_\\mu$$ to 140 ppb, a factor of 4 improvement in the uncertainty the previous measurement. This improvement in precision, combined with recent improvements in our understanding of the QCD contributions to the muon $g$-$2$, could provide a discrepancy from the standard model greater than 7$$\\sigma$$ if the central value is the same as that measured by the BNL experiment, which would be a clear indication of new physics.« less
The Muon g-2 experiment at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapelain, Antoine
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.
The Muon g-2 experiment at Fermilab
NASA Astrophysics Data System (ADS)
Chapelain, Antoine
2017-03-01
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.
Spectral radiative properties of a living human body
NASA Astrophysics Data System (ADS)
Terada, N.; Ohnishi, K.; Kobayashi, M.; Kunitomo, T.
1986-09-01
Spectral radiative properties of the human body were studied experimentally in the region from the ultraviolet to the far-infrared to know the thermal response of the human body exposed to solar radiation and infrared radiation. The measuring equipment for reflectance and transmittance of a semitransparent scattering medium was developed and measurement on a living human skin was performed in vivo. The measured parts are forearm, cheek, dorsum hand, hip, and hair. The values obtained by the present study are much different from those of previous in vitro measurements. Fairly large values for hemispherical reflectances are observed in the visible and near-infrared regions but very small values for hemispherical reflectances are observed in the infrared region, below 0.05. By applying the four-flux treatment of radiative transfer, the absorption coefficient and scattering coefficient in the human skin are determined. The scattering coefficient is large in the visible region but negligible in the infrared region. The absorption coefficient is very close to that of water and large in the infrared region.
Direct measurement of methane hydrate composition along the hydrate equilibrium boundary
Circone, S.; Kirby, S.H.; Stern, L.A.
2005-01-01
The composition of methane hydrate, namely nW for CH 4??nWH2O, was directly measured along the hydrate equilibrium boundary under conditions of excess methane gas. Pressure and temperature conditions ranged from 1.9 to 9.7 MPa and 263 to 285 K. Within experimental error, there is no change in hydrate composition with increasing pressure along the equilibrium boundary, but nW may show a slight systematic decrease away from this boundary. A hydrate stoichiometry of n W = 5.81-6.10 H2O describes the entire range of measured values, with an average composition of CH4??5.99(??0.07) H2O along the equilibrium boundary. These results, consistent with previously measured values, are discussed with respect to the widely ranging values obtained by thermodynamic analysis. The relatively constant composition of methane hydrate over the geologically relevant pressure and temperature range investigated suggests that in situ methane hydrate compositions may be estimated with some confidence. ?? 2005 American Chemical Society.
NASA Technical Reports Server (NTRS)
Bertsch, D. L.; Biswas, S.; Fichtel, C. E.; Pellerin, C. J.; Reames, D. V.
1973-01-01
Measurements of the flux of helium nuclei in the 24 January 1971 event and of helium and (C,N,O) nuclei in the 1 September 1971 event are combined with previous measurements to obtain the relative abundances of helium, (C,N,O), and Fe-group nuclei in these events. These data are then summarized together with previously reported results to show that, even when the same detector system using a dE/dx plus range technique is used, differences in the He/(C,N,O) value in the same energy/nucleon interval are observed in solar cosmic ray events. Further, when the He/(C,N,O) value is lower the He/(Fe-group nuclei) value is also systematically lower in these large events. When solar particle acceleration theory is analyzed, it is seen that the results suggest that, for large events, Coulomb energy loss probably does not play a major role in determining solar particle composition at higher energies (10 MeV). The variations in multicharged nuclei composition are more likely due to partial ionization during the acceleration phase.
[2-3 diphosphoglycerate and tissue oxygenation in the cirrhotic].
Vendemiale, G; Altomare, E; Stufano, N; Procacci, V; Albano, O
1985-01-30
Increased 2-3 Diphosphoglycerate levels in cirrhotic patients have been reported. Previous studies did not show significant changes in 2-3 DPG in anaemic cirrhotic patients when compared to non anaemic cirrhotic patients, but the role played by alkalosis and/or hypoxia has not been investigated. To study this question, haematic 2-3 DPG was measured in 8 male patients with liver cirrhosis (histologically diagnosed) together with PO2, PCO2, pH and Hct. 2-3 DPG was also measured in 6 healthy male volunteers. We found a significant increase in blood 2-3 DPG of cirrhotic patients compared to control subjects (5,55 +/- 0,4 vs 2,18 +/- 0,3 mmol/l erythrocytes respectively, p less than 0,001) in agreement with previous studies. PO2 levels and Hct value did not show important changes, whereas PCO2 and pH resulted to be very altered when compared to normal values, even though we could not correlate these values with blood 2-3 DPG. We conclude that the genesis of 2-3 DPG increase is multifactorial, however an alteration in acid-base equilibrium seems to play a more important role than hypoxia.
Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold
NASA Astrophysics Data System (ADS)
Xu, Jingke; Shields, Emily; Calaprice, Frank; Westerdale, Shawn; Froborg, Francis; Suerfu, Burkhant; Alexander, Thomas; Aprahamian, Ani; Back, Henning O.; Casarella, Clark; Fang, Xiao; Gupta, Yogesh K.; Ianni, Aldo; Lamere, Edward; Lippincott, W. Hugh; Liu, Qian; Lyons, Stephanie; Siegl, Kevin; Smith, Mallory; Tan, Wanpeng; Kolk, Bryant Vande
2015-07-01
The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies but fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.
Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Jingke; Shields, Emily; Calaprice, Frank
2015-07-01
The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies butmore » fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.« less
406 E Grand, October 2010, Lindsay Light Radiological Survey
The field gamma measurements within the excavation and the spoil materials generated during the excavation process did not exceed the respective threshold values previously stated and ranged from a minim um of 1, 120 cpm to a maxim um of 6,640 cpm.
THE SPIN OF THE BLACK HOLE 4U 1543-47
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morningstar, Warren R.; Miller, Jon M., E-mail: wmorning@umich.edu, E-mail: jonmm@umich.edu
2014-10-01
We present a new analysis of Rossi X-Ray Timing Explorer observations of the 2002 outburst of the transient X-ray nova 4U 1543-47. We focus on observations in the high/soft state, and attempt to measure the ''spin'' of the black hole by simultaneously fitting the thermal disk continuum and by modeling the broadened iron k-shell emission lines and additional blurred reflection features. Previous works have found that use of these methods individually returns contradictory values for the dimensionless spin parameter a {sub *} = cJ/GM {sup 2}. We find that when used in conjunction with each other, a moderate spin ismore » obtained (a{sub ∗}=0.43{sub −0.31}{sup +0.22}) that is actually consistent with both other values within errors. We discuss limitations of our analysis, systematic uncertainties, and implications of this measurement, and compare our result to those previously claimed for 4U 1543-47.« less
NASA Astrophysics Data System (ADS)
Werner, V.; Cooper, N.; Régis, J.-M.; Rudigier, M.; Williams, E.; Jolie, J.; Cakirli, R. B.; Casten, R. F.; Ahn, T.; Anagnostatou, V.; Berant, Z.; Bonett-Matiz, M.; Elvers, M.; Heinz, A.; Ilie, G.; Radeck, D.; Savran, D.; Smith, M. K.
2016-03-01
The B (E 2 ) excitation strength of the first excited 2+ state in even-even nuclei should directly correlate with the size of the valence space and maximize at mid-shell. A previously found saturation of B (E 2 ) strengths in well-deformed rotors at mid-shell is tested through high-precision measurements of the lifetimes of the lowest-lying 2+ states of the 168Hf and 174W rare earth isotopes. Measurements were performed using fast LaBr3 scintillation detectors. Combined with the recently remeasured B (E 2 ;21+→01+) values for Hf and W isotopes the new data remove discrepancies observed in the differentials of B (E 2 ) values for these isotopes.
Sensitivity of solar-cell performance to atmospheric variables. 1: Single cell
NASA Technical Reports Server (NTRS)
Klucher, T. M.
1976-01-01
The short circuit current of a typical silicon solar cell under direct solar radiation was measured for a range of turbidity, water vapor content, and air mass to determine the relation of the solar cell calibration value (current-to-intensity ratio) to those atmospheric variables. A previously developed regression equation was modified to describe the relation between calibration value, turbidity, water vapor content, and air mass. Based on the value of the constants obtained by a least squares fit of the data to the equation, it was found that turbidity lowers the value, while increase in water vapor increases the calibration value. Cell calibration values exhibited a change of about 6% over the range of atmospheric conditions experienced.
THE INCLINATION OF THE SOFT X-RAY TRANSIENT A0620-00 AND THE MASS OF ITS BLACK HOLE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantrell, Andrew G.; Bailyn, Charles D.; Orosz, Jerome A.
2010-02-20
We analyze photometry of the soft X-ray transient A0620 - 00 spanning nearly 30 years, including previously published and previously unpublished data. Previous attempts to determine the inclination of A0620 using subsets of these data have yielded a wide range of measured values of i. Differences in the measured value of i have been due to changes in the shape of the light curve and uncertainty regarding the contamination from the disk. We give a new technique for estimating the disk fraction and find that disk light is significant in all light curves, even in the infrared. We also findmore » that all changes in the shape and normalization of the light curve originate in a variable disk component. After accounting for this disk component, we find that all the data, including light curves of significantly different shapes, point to a consistent value of i. Combining results from many separate data sets, we find i = 51.{sup 0}0 +- 0.{sup 0}9, implying M = 6.6 +- 0.25 M{sub sun}. Using our dynamical model and zero-disk stellar VIH magnitudes, we find d = 1.06 +- 0.12 kpc. Understanding the disk origin of nonellipsoidal variability may assist with making reliable determinations of i in other systems, and the fluctuations in disk light may provide a new observational tool for understanding the three-dimensional structure of the accretion disk.« less
The Inclination of the Soft X-Ray Transient A0620-00 and the Mass of its Black Hole
NASA Astrophysics Data System (ADS)
Cantrell, Andrew G.; Bailyn, Charles D.; Orosz, Jerome A.; McClintock, Jeffrey E.; Remillard, Ronald A.; Froning, Cynthia S.; Neilsen, Joseph; Gelino, Dawn M.; Gou, Lijun
2010-02-01
We analyze photometry of the soft X-ray transient A0620 - 00 spanning nearly 30 years, including previously published and previously unpublished data. Previous attempts to determine the inclination of A0620 using subsets of these data have yielded a wide range of measured values of i. Differences in the measured value of i have been due to changes in the shape of the light curve and uncertainty regarding the contamination from the disk. We give a new technique for estimating the disk fraction and find that disk light is significant in all light curves, even in the infrared. We also find that all changes in the shape and normalization of the light curve originate in a variable disk component. After accounting for this disk component, we find that all the data, including light curves of significantly different shapes, point to a consistent value of i. Combining results from many separate data sets, we find i = 51fdg0 ± 0fdg9, implying M = 6.6 ± 0.25 M sun. Using our dynamical model and zero-disk stellar VIH magnitudes, we find d = 1.06 ± 0.12 kpc. Understanding the disk origin of nonellipsoidal variability may assist with making reliable determinations of i in other systems, and the fluctuations in disk light may provide a new observational tool for understanding the three-dimensional structure of the accretion disk.
Interoceptive ability predicts aversion to losses.
Sokol-Hessner, Peter; Hartley, Catherine A; Hamilton, Jeffrey R; Phelps, Elizabeth A
2015-01-01
Emotions have been proposed to inform risky decision-making through the influence of affective physiological responses on subjective value. The ability to perceive internal body states, or "interoception" may influence this relationship. Here, we examined whether interoception predicts participants' degree of loss aversion, which has been previously linked to choice-related arousal responses. Participants performed both a heartbeat-detection task indexing interoception and a risky monetary decision-making task, from which loss aversion, risk attitudes and choice consistency were parametrically measured. Interoceptive ability correlated selectively with loss aversion and was unrelated to the other value parameters. This finding suggests that specific and separable component processes underlying valuation are shaped not only by our physiological responses, as shown in previous findings, but also by our interoceptive access to such signals.
Temsch, W; Luger, A; Riedl, M
2008-01-01
This article presents a mathematical model to calculate HbA1c values based on self-measured blood glucose and past HbA1c levels, thereby enabling patients to monitor diabetes therapy between scheduled checkups. This method could help physicians to make treatment decisions if implemented in a system where glucose data are transferred to a remote server. The method, however, cannot replace HbA1c measurements; past HbA1c values are needed to gauge the method. The mathematical model of HbA1c formation was developed based on biochemical principles. Unlike an existing HbA1c formula, the new model respects the decreasing contribution of older glucose levels to current HbA1c values. About 12 standard SQL statements embedded in a php program were used to perform Fourier transform. Regression analysis was used to gauge results with previous HbA1c values. The method can be readily implemented in any SQL database. The predicted HbA1c values thus obtained were in accordance with measured values. They also matched the results of the HbA1c formula in the elevated range. By contrast, the formula was too "optimistic" in the range of better glycemic control. Individual analysis of two subjects improved the accuracy of values and reflected the bias introduced by different glucometers and individual measurement habits.
Crichton, Georgina E; Elias, Merrill F; Dore, Gregory A; Torres, Rachael V; Robbins, Michael A
2014-11-01
The objective was to investigate the association between variability in blood pressure (BP) and cognitive function for sitting, standing, and reclining BP values and variability derived from all 15 measures. In previous studies, only sitting BP values have been examined, and only a few cognitive measures have been used. A secondary objective was to examine associations between BP variability and cognitive performance in hypertensive individuals stratified by treatment success. Cross-sectional analyses were performed on 972 participants of the Maine Syracuse Study for whom 15 serial BP clinic measures (5 sitting, 5 recumbent, and 5 standing) were obtained before testing of cognitive performance. Using all 15 measures, higher variability in systolic and diastolic BP was associated with poorer performance on multiple measures of cognitive performance, independent of demographic factors, cardiovascular risk factors, and pulse pressure. When sitting, reclining, and standing systolic BP values were compared, only variability in standing BP was related to measures of cognitive performance. However, for diastolic BP, variability in all 3 positions was related to cognitive performance. Mean BP values were weaker predictors of cognition. Furthermore, higher overall variability in both systolic and diastolic BP was associated with poorer cognitive performance in unsuccessfully treated hypertensive individuals (with BP ≥140/90 mm Hg), but these associations were not evident in those with controlled hypertension. © 2014 American Heart Association, Inc.
Characterization of measurements in quantum communication. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Chan, V. W. S.
1975-01-01
A characterization of quantum measurements by operator valued measures is presented. The generalized measurements include simultaneous approximate measurement of noncommuting observables. This characterization is suitable for solving problems in quantum communication. Two realizations of such measurements are discussed. The first is by adjoining an apparatus to the system under observation and performing a measurement corresponding to a self-adjoint operator in the tensor-product Hilbert space of the system and apparatus spaces. The second realization is by performing, on the system alone, sequential measurements that correspond to self-adjoint operators, basing the choice of each measurement on the outcomes of previous measurements. Simultaneous generalized measurements are found to be equivalent to a single finer grain generalized measurement, and hence it is sufficient to consider the set of single measurements. An alternative characterization of generalized measurement is proposed. It is shown to be equivalent to the characterization by operator-values measures, but it is potentially more suitable for the treatment of estimation problems. Finally, a study of the interaction between the information-carrying system and a measurement apparatus provides clues for the physical realizations of abstractly characterized quantum measurements.
Measurement of the proton structure function F 2 from the 1993 HERA data
NASA Astrophysics Data System (ADS)
Derrick, M.; Krakauer, D.; Magill, S.; Musgrave, B.; Repond, J.; Schlereth, J.; Stanek, R.; Talaga, R. L.; Thron, J.; Arzarello, F.; Ayad, R.; Bari, G.; Basile, M.; Bellagamba, L.; Boscherini, D.; Bruni, A.; Bruni, G.; Bruni, P.; Cara Romeo, G.; Castellini, G.; Chiarini, M.; Cifarelli, L.; Cindolo, F.; Ciralli, F.; Contin, A.; D'Auria, S.; Frasconi, F.; Giusti, P.; Iacobucci, G.; Laurenti, G.; Levi, G.; Margotti, A.; Massam, T.; Nania, R.; Nemoz, C.; Palmonari, F.; Polini, A.; Sartorelli, G.; Timellini, R.; Zamora Garcia, Y.; Zichichi, A.; Bargende, A.; Crittenden, J.; Desch, K.; Diekmann, B.; Doeker, T.; Feld, L.; Frey, A.; Geerts, M.; Geitz, G.; Grothe, M.; Hartmann, H.; Haun, D.; Heinloth, K.; Hilger, E.; Jakob, H.-P.; Katz, U. F.; Mari, S. M.; Mass, A.; Mengel, S.; Mollen, J.; Paul, E.; Rembser, Ch.; Schattevoy, R.; Schneider, J.-L.; Schramm, D.; Stamm, J.; Wedemeyer, R.; Campbell-Robson, S.; Cassidy, A.; Dyce, N.; Foster, B.; George, S.; Gilmore, R.; Heath, G. P.; Heath, H. F.; Llewellyn, T. J.; Morgado, C. J. S.; Norman, D. J. P.; O'Mara, J. A.; Tapper, R. J.; Wilson, S. S.; Yoshida, R.; Rau, R. R.; Arneodo, M.; Iannotti, L.; Schioppa, M.; Susinno, G.; Bernstein, A.; Caldwell, A.; Gialas, I.; Parsons, J. A.; Ritz, S.; Sciulli, F.; Straub, P. B.; Wai, L.; Yang, S.; Borzemski, P.; Chwastowski, J.; Eskreys, A.; Piotrzkowski, K.; Zachara, M.; Zawiejski, L.; Adamczyk, L.; Bednarek, B.; Eskreys, K.; Jeleń, K.; Kisielewska, D.; Kowalski, T.; Rulikowska-Zarębska, E.; Suszycki, L.; Zając, J.; Kędzierski, T.; Kotański, A.; Przybycień, M.; Bauerdick, L. A. T.; Behrens, U.; Bienlein, J. K.; Böttcher, S.; Coldewey, C.; Drews, G.; Flasiński, M.; Gilkinson, D. J.; Göttlicher, P.; Gutjahr, B.; Haas, T.; Hagge, L.; Hain, W.; Hasell, D.; Heßling, H.; Hultschig, H.; Iga, Y.; Joos, P.; Kasemann, M.; Klanner, R.; Koch, W.; Köpke, L.; Kötz, U.; Kowalski, H.; Kröger, W.; Krüger, J.; Labs, J.; Ladage, A.; Löhr, B.; Löwe, M.; Lüke, D.; Mainusch, J.; Mańczak, O.; Ng, J. S. T.; Nickel, S.; Notz, D.; Ohrenberg, K.; Roco, M.; Rohde, M.; Roldán, J.; Schneekloth, U.; Schulz, W.; Selonke, F.; Stiliaris, E.; Voß, T.; Westphal, D.; Wolf, G.; Youngman, C.; Grabosch, H. J.; Leich, A.; Meyer, A.; Rethfeldt, C.; Schlenstedt, S.; Barbagli, G.; Pelfer, P.; Anzivino, G.; Maccarrone, G.; de Pasquale, S.; Qian, S.; Votano, L.; Bamberger, A.; Freidhof, A.; Poser, T.; Söldner-Rembold, S.; Schroeder, J.; Theisen, G.; Trefzger, T.; Brook, N. H.; Bussey, P. J.; Doyle, A. T.; Fleck, I.; Jamieson, V. A.; Saxon, D. H.; Utley, M. L.; Wilson, A. S.; Dannemann, A.; Holm, U.; Horstmann, D.; Kammerlocher, H.; Krebs, B.; Neumann, T.; Sinkus, R.; Wick, K.; Badura, E.; Burow, B. D.; Fürtjes, A.; Lohrmann, E.; Milewski, J.; Nakahata, M.; Pavel, N.; Poelz, G.; Schott, W.; Terron, J.; Zetsche, F.; Bacon, T. C.; Beuselinck, R.; Butterworth, I.; Gallo, E.; Harris, V. L.; Hung, B. H.; Long, K. R.; Miller, D. B.; Morawitz, P. P. O.; Prinias, A.; Sedgbeer, J. K.; Whitfield, A. F.; Mallik, U.; McCliment, E.; Wang, M. Z.; Zhang, Y.; Cloth, P.; Filges, D.; An, S. H.; Hong, S. M.; Nam, S. W.; Park, S. K.; Suh, M. H.; Yon, S. H.; Imlay, R.; Kartik, S.; Kim, H.-J.; McNeil, R. R.; Metcalf, W.; Nadendla, V. K.; Barreiro, F.; Cases, G.; Graciani, R.; Hernández, J. M.; Hervás, L.; Labarga, L.; Del Peso, J.; Puga, J.; de Trocóniz, J. F.; Ikraiam, F.; Mayer, J. K.; Smith, G. R.; Corriveau, F.; Hanna, D. S.; Hartmann, J.; Hung, L. W.; Lim, J. N.; Matthews, C. G.; Mitchell, J. W.; Patel, P. M.; Sinclair, L. E.; Stairs, D. G.; St. Laurent, M.; Ullmann, R.; Bashkirov, V.; Dolgoshein, B. A.; Stifutkin, A.; Bashindzhagyan, G. L.; Ermolov, P. F.; Gladilin, L. K.; Golubkov, Y. A.; Kobrin, V. D.; Kuzmin, V. A.; Proskuryakov, A. S.; Savin, A. A.; Shcheglova, L. M.; Solomin, A. N.; Zotov, N. P.; Bentvelsen, S.; Botje, M.; Chlebana, F.; Dake, A.; Engelen, J.; de Jong, P.; de Kamps, M.; Kooijman, P.; Kruse, A.; O'Dell, V.; Tenner, A.; Tiecke, H.; Verkerke, W.; Vreeswijk, M.; Wiggers, L.; de Wolf, E.; van Woudenberg, R.; Acosta, D.; Bylsma, B.; Durkin, L. S.; Honscheid, K.; Li, C.; Ling, T. Y.; McLean, K. W.; Murray, W. N.; Park, I. H.; Romanowski, T. A.; Seidlein, R.; Bailey, D. S.; Blair, G. A.; Byrne, A.; Cashmore, R. J.; Cooper-Sarkar, A. M.; Daniels, D.; Devenish, R. C. E.; Harnew, N.; Lancaster, M.; Luffman, P. E.; Lindemann, L.; McFall, J.; Nath, C.; Quadt, A.; Uijterwaal, H.; Walczak, R.; Wilson, F. F.; Yip, T.; Abbiendi, G.; Bertolin, A.; Brugnera, R.; Carlin, R.; Dal Corso, F.; de Giorgi, M.; Dosselli, U.; Gasparini, F.; Limentani, S.; Morandin, M.; Posocco, M.; Stanco, L.; Stroili, R.; Voci, C.; Bulmahn, J.; Butterworth, J. M.; Feild, R. G.; Oh, B. Y.; Whitmore, J. J.; D'Agostini, G.; Iori, M.; Marini, G.; Mattioli, M.; Nigro, A.; Tassi, E.; Hart, J. C.; McCubbin, N. A.; Prytz, K.; Shah, T. P.; Short, T. L.; Barberis, E.; Cartiglia, N.; Dubbs, T.; Heusch, C.; van Hook, M.; Hubbard, B.; Lockman, W.; Rahn, J. T.; Sadrozinski, H. F.-W.; Seiden, A.; Biltzinger, J.; Seifert, R. J.; Walenta, A. H.; Zech, G.; Abramowicz, H.; Briskin, G.; Dagan, S.; Levy, A.; Hasegawa, T.; Hazumi, M.; Ishii, T.; Kuze, M.; Mine, S.; Nagasawa, Y.; Nagira, T.; Nakao, M.; Suzuki, I.; Tokushuku, K.; Yamada, S.; Yamazaki, Y.; Chiba, M.; Hamatsu, R.; Hirose, T.; Homma, K.; Kitamura, S.; Nagayama, S.; Nakamitsu, Y.; Cirio, R.; Costa, M.; Ferrero, M. I.; Lamberti, L.; Maselli, S.; Peroni, C.; Sacchi, R.; Solano, A.; Staiano, A.; Dardo, M.; Bandyopadhyay, D.; Benard, F.; Brkic, M.; Crombie, M. B.; Gingrich, D. M.; Hartner, G. F.; Joo, K. K.; Levman, G. M.; Martin, J. F.; Orr, R. S.; Sampson, C. R.; Teuscher, R. J.; Catterall, C. D.; Jones, T. W.; Kaziewicz, P. B.; Lane, J. B.; Saunders, R. L.; Shulman, J.; Blankenship, K.; Kochocki, J.; Lu, B.; Mo, L. W.; Bogusz, W.; Charchula, K.; Ciborowski, J.; Gajewski, J.; Grzelak, G.; Kasprzak, M.; Krzyżanowski, M.; Muchorowski, K.; Nowak, R. J.; Pawlak, J. M.; Tymieniecka, T.; Wróblewski, A. K.; Zakrzewski, J. A.; Żarnecki, A. F.; Adamus, M.; Eisenberg, Y.; Glasman, C.; Karshon, U.; Revel, D.; Shapira, A.; Ali, I.; Behrens, B.; Dasu, S.; Fordham, C.; Foudas, C.; Goussiou, A.; Loveless, R. J.; Reeder, D. D.; Silverstein, S.; Smith, W. H.; Tsurugai, T.; Bhadra, S.; Frisken, W. R.; Furutani, K. M.
1995-09-01
The ZEUS detector has been used to measure the proton structure function F 2. During 1993 HERA collided 26.7 GeV electrons on 820 GeV protons. The data sample corresponds to an integrated luminosity of 0.54 pb-1, representing a twenty fold increase in statistics compared to that of 1992. Results are presented for 7< Q 2<104 GeV2 and x values as low as 3×10-4. The rapid rise in F 2 as x decreases observed previously is now studied in greater detail and persists for Q 2 values up to 500 GeV2.
NASA Technical Reports Server (NTRS)
Mcdonald, G.
1980-01-01
Black cobalt oxide coatings (high solar absorptance layer) were deposited on thin layers of silver or gold (low emittance layer) which had been previously deposited on oxidized (diffusion barrier layer) stainless steel substrates. The reflectance properties of these coatings were measured at various thicknesses of cobalt for integrated values of the solar and infrared spectrum. The values of absorptance and emittance were calculated from the measured reflectance values, before and after exposure in air at 650 C for approximately 1000 hours. Absorptance and emittance were interdependent functions of the weight of cobalt oxide. Also, these cobalt oxide/noble metal/oxide diffusion barrier coatings have absorptances greater than 0.90 and emittances of approximately 0.20 even after about 1000 hours at 650 C.
Seawater 234U/238U recorded by modern and fossil corals
NASA Astrophysics Data System (ADS)
Chutcharavan, Peter M.; Dutton, Andrea; Ellwood, Michael J.
2018-03-01
U-series dating of corals is a crucial tool for generating absolute chronologies of Late Quaternary sea-level change and calibrating the radiocarbon timescale. Unfortunately, coralline aragonite is susceptible to post-depositional alteration of its primary geochemistry. One screening technique used to identify unaltered corals relies on the back-calculation of initial 234U/238U activity (δ234Ui) at the time of coral growth and implicitly assumes that seawater δ234U has remained constant during the Late Quaternary. Here, we test this assumption using the most comprehensive compilation to date of coral U-series measurements. Unlike previous compilations, this study normalizes U-series measurements to the same decay constants and corrects for offsets in interlaboratory calibrations, thus reducing systematic biases between reported δ234U values. Using this approach, we reassess (a) the value of modern seawater δ234U, and (b) the evolution of seawater δ234U over the last deglaciation. Modern coral δ234U values (145.0 ± 1.5‰) agree with previous measurements of seawater and modern corals only once the data have been normalized. Additionally, fossil corals in the surface ocean display δ234Ui values that are ∼5-7‰ lower during the last glacial maximum regardless of site, taxon, or diagenetic setting. We conclude that physical weathering of U-bearing minerals exposed during ice sheet retreat drives the increase in δ234U observed in the oceans, a mechanism that is consistent with the interpretation of the seawater Pb-isotope signal over the same timescale.
Formal Definition of Measures for BPMN Models
NASA Astrophysics Data System (ADS)
Reynoso, Luis; Rolón, Elvira; Genero, Marcela; García, Félix; Ruiz, Francisco; Piattini, Mario
Business process models are currently attaining more relevance, and more attention is therefore being paid to their quality. This situation led us to define a set of measures for the understandability of BPMN models, which is shown in a previous work. We focus on understandability since a model must be well understood before any changes are made to it. These measures were originally informally defined in natural language. As is well known, natural language is ambiguous and may lead to misunderstandings and a misinterpretation of the concepts captured by a measure and the way in which the measure value is obtained. This has motivated us to provide the formal definition of the proposed measures using OCL (Object Constraint Language) upon the BPMN (Business Process Modeling Notation) metamodel presented in this paper. The main advantages and lessons learned (which were obtained both from the current work and from previous works carried out in relation to the formal definition of other measures) are also summarized.
NASA Astrophysics Data System (ADS)
Galewsky, Joseph; Rella, Christopher; Sharp, Zachary; Samuels, Kimberly; Ward, Dylan
2011-09-01
Simultaneous, real-time measurements of atmospheric water vapor mixing ratio and isotopic composition (δD and δ18O) were obtained using cavity ringdown spectroscopy on the arid Chajnantor Plateau in the subtropical Chilean Andes (elevation 5080 m or 550 hPa; latitude 23°S) during July and August 2010. The measurements show surface water vapor mixing ratio as low as 215 ppmv, δD values as low as -540‰, and δ18O values as low as -68‰, which are the lowest atmospheric water vapor δ values reported from Earth's surface. The results are consistent with previous measurements from the base of the tropical tropopause layer (TTL) and suggest large-scale subsidence of air masses from the upper troposphere to the Earth's surface. The range of measurements is consistent with condensation under conditions of ice supersaturation and mixing with moister air from the lower troposphere that has been processed through shallow convection. Diagnostics using reanalysis data show that the extreme aridity of the Chajnantor Plateau is controlled by condensation in the upper tropical troposphere.
Fundamentals of in Situ Digital Camera Methodology for Water Quality Monitoring of Coast and Ocean
Goddijn-Murphy, Lonneke; Dailloux, Damien; White, Martin; Bowers, Dave
2009-01-01
Conventional digital cameras, the Nikon Coolpix885® and the SeaLife ECOshot®, were used as in situ optical instruments for water quality monitoring. Measured response spectra showed that these digital cameras are basically three-band radiometers. The response values in the red, green and blue bands, quantified by RGB values of digital images of the water surface, were comparable to measurements of irradiance levels at red, green and cyan/blue wavelengths of water leaving light. Different systems were deployed to capture upwelling light from below the surface, while eliminating direct surface reflection. Relationships between RGB ratios of water surface images, and water quality parameters were found to be consistent with previous measurements using more traditional narrow-band radiometers. This current paper focuses on the method that was used to acquire digital images, derive RGB values and relate measurements to water quality parameters. Field measurements were obtained in Galway Bay, Ireland, and in the Southern Rockall Trough in the North Atlantic, where both yellow substance and chlorophyll concentrations were successfully assessed using the digital camera method. PMID:22346729
NASA Astrophysics Data System (ADS)
Soulis, K. X.; Valiantzas, J. D.
2011-10-01
The Soil Conservation Service Curve Number (SCS-CN) approach is widely used as a simple method for predicting direct runoff volume for a given rainfall event. The CN values can be estimated by being selected from tables. However, it is more accurate to estimate the CN value from measured rainfall-runoff data (assumed available) in a watershed. Previous researchers indicated that the CN values calculated from measured rainfall-runoff data vary systematically with the rainfall depth. They suggested the determination of a single asymptotic CN value observed for very high rainfall depths to characterize the watersheds' runoff response. In this paper, the novel hypothesis that the observed correlation between the calculated CN value and the rainfall depth in a watershed reflects the effect of the inevitable presence of soil-cover complex spatial variability along watersheds is being tested. Based on this hypothesis, the simplified concept of a two-CN heterogeneous system is introduced to model the observed CN-rainfall variation by reducing the CN spatial variability into two classes. The behavior of the CN-rainfall function produced by the proposed two-CN system concept is approached theoretically, it is analyzed systematically, and it is found to be similar to the variation observed in natural watersheds. Synthetic data tests, natural watersheds examples, and detailed study of two natural experimental watersheds with known spatial heterogeneity characteristics were used to evaluate the method. The results indicate that the determination of CN values from rainfall runoff data using the proposed two-CN system approach provides reasonable accuracy and it over performs the previous original method based on the determination of a single asymptotic CN value. Although the suggested method increases the number of unknown parameters to three (instead of one), a clear physical reasoning for them is presented.
NASA Astrophysics Data System (ADS)
Bindeman, I. N.; Dixon, J. E.; Langmuir, C. H.; Palandri, J. L.
2015-12-01
The advent and calibration of the Thermal Combustion Element Analyzer (TCEA) continuous flow system coupled with the large-radius mass spectrometer MAT253 permits precise (±0.02 wt.% H2O, ±1-3‰ D/H) measurements in 1-10 mg of volcanic glass (0.1 wt.% H2O requires ~10 mg glass), which permits the targeting of small amounts of the freshest concentrate. This is a >100 factor reduction in sample size over conventional methods, four times over more common Delta series instruments. We investigated in triplicate 115 samples of submarine MORB glasses ranging from water-poor (0.1-0.2wt%) to water-rich (1.2-1.5wt%). These samples were previously investigated for major and trace elements, radiogenic isotopes; a large subset of these samples coming from the FAZAR expedition were studied previously by FTIR for water concentration. We also ran samples previously studied by the conventional off-line technique: MORB glass including those from the Easter Platform and the Alvin 526-1 standard (0.2wt% H2O). We observe excellent 1:1 correspondence (1.02x+0.02, R2=0.94) of wt% water by FTIR and TCEA suggesting complete extraction of water and no dependence on water concentration. We measure 51‰ total range in D/H that correlates with all other chemical and isotopic indicators of mantle enrichment, with the heaviest values occurring in the most enriched samples. When used uncorrected values of H2 gas run against H2 gas of known composition, this range agrees nicely with previous D/H range for MORB (-30 to -90‰), measured for samples run conventionally. Uncorrected analyses of Alvin glass 526-1 gives -66‰. When run against SMOW, SLAP and -41‰ water sealed in silver cups, the range is shifted by -15‰; when standardization is done by with three commonly used mica standards as is done most commonly in different labs, the range is shifted downward by -30-32‰. There are no isotopic offsets related to total water or D/H range requiring different slope or non-linear correction. The NBS30 mica standard has been recently shown to be heavier and more heterogeneous than previously thought, and older conventional methods that relied on Pt reduction unreliable. Based on these new TCEA results, the D/H values of MORB and mantle samples may need to be revised to lighter values by 15‰.
Determining the ventilation and aerosol deposition rates from routine indoor-air measurements.
Halios, Christos H; Helmis, Costas G; Deligianni, Katerina; Vratolis, Sterios; Eleftheriadis, Konstantinos
2014-01-01
Measurement of air exchange rate provides critical information in energy and indoor-air quality studies. Continuous measurement of ventilation rates is a rather costly exercise and requires specific instrumentation. In this work, an alternative methodology is proposed and tested, where the air exchange rate is calculated by utilizing indoor and outdoor routine measurements of a common pollutant such as SO2, whereas the uncertainties induced in the calculations are analytically determined. The application of this methodology is demonstrated, for three residential microenvironments in Athens, Greece, and the results are also compared against ventilation rates calculated from differential pressure measurements. The calculated time resolved ventilation rates were applied to the mass balance equation to estimate the particle loss rate which was found to agree with literature values at an average of 0.50 h(-1). The proposed method was further evaluated by applying a mass balance numerical model for the calculation of the indoor aerosol number concentrations, using the previously calculated ventilation rate, the outdoor measured number concentrations and the particle loss rates as input values. The model results for the indoors' concentrations were found to be compared well with the experimentally measured values.
Olfactory Threshold of Chlorine in Oxygen.
1977-09-01
The odor threshold of chlorine in oxygen was determined. Measurements were conducted in an altitude chamber, which provided an odor-free and noise...free background. Human male volunteers, with no previous olfactory acuity testing experience, served as panelists. Threshold values were affected by...time intervals between trials and by age differences. The mean threshold value for 11 subjects was 0.08 ppm obtained by positive responses to the lowest detectable level of chlorine in oxygen, 50% of the time. (Author)
VHDL-AMS modelling and simulation of a planar electrostatic micromotor
NASA Astrophysics Data System (ADS)
Endemaño, A.; Fourniols, J. Y.; Camon, H.; Marchese, A.; Muratet, S.; Bony, F.; Dunnigan, M.; Desmulliez, M. P. Y.; Overton, G.
2003-09-01
System level simulation results of a planar electrostatic micromotor, based on analytical models of the static and dynamic torque behaviours, are presented. A planar variable capacitance (VC) electrostatic micromotor designed, fabricated and tested at LAAS (Toulouse) in 1995 is simulated using the high level language VHDL-AMS (VHSIC (very high speed integrated circuits) hardware description language-analog mixed signal). The analytical torque model is obtained by first calculating the overlaps and capacitances between different electrodes based on a conformal mapping transformation. Capacitance values in the order of 10-16 F and torque values in the order of 10-11 N m have been calculated in agreement with previous measurements and simulations from this type of motor. A dynamic model has been developed for the motor by calculating the inertia coefficient and estimating the friction-coefficient-based values calculated previously for other similar devices. Starting voltage results obtained from experimental measurement are in good agreement with our proposed simulation model. Simulation results of starting voltage values, step response, switching response and continuous operation of the micromotor, based on the dynamic model of the torque, are also presented. Four VHDL-AMS blocks were created, validated and simulated for power supply, excitation control, micromotor torque creation and micromotor dynamics. These blocks can be considered as the initial phase towards the creation of intellectual property (IP) blocks for microsystems in general and electrostatic micromotors in particular.
Nuclear DNA amounts in angiosperms: progress, problems and prospects.
Bennett, M D; Leitch, I J
2005-01-01
The nuclear DNA amount in an unreplicated haploid chromosome complement (1C-value) is a key diversity character with many uses. Angiosperm C-values have been listed for reference purposes since 1976, and pooled in an electronic database since 1997 (http://www.kew.org/cval/homepage). Such lists are cited frequently and provide data for many comparative studies. The last compilation was published in 2000, so a further supplementary list is timely to monitor progress against targets set at the first plant genome size workshop in 1997 and to facilitate new goal setting. The present work lists DNA C-values for 804 species including first values for 628 species from 88 original sources, not included in any previous compilation, plus additional values for 176 species included in a previous compilation. 1998-2002 saw striking progress in our knowledge of angiosperm C-values. At least 1700 first values for species were measured (the most in any five-year period) and familial representation rose from 30 % to 50 %. The loss of many densitometers used to measure DNA C-values proved less serious than feared, owing to the development of relatively inexpensive flow cytometers and computer-based image analysis systems. New uses of the term genome (e.g. in 'complete' genome sequencing) can cause confusion. The Arabidopsis Genome Initiative C-value for Arabidopsis thaliana (125 Mb) was a gross underestimate, and an exact C-value based on genome sequencing alone is unlikely to be obtained soon for any angiosperm. Lack of this expected benchmark poses a quandary as to what to use as the basal calibration standard for angiosperms. The next decade offers exciting prospects for angiosperm genome size research. The database (http://www.kew.org/cval/homepage) should become sufficiently representative of the global flora to answer most questions without needing new estimations. DNA amount variation will remain a key interest as an integrated strand of holistic genomics.
Automatic, nondestructive test monitors in-process weld quality
NASA Technical Reports Server (NTRS)
Deal, F. C.
1968-01-01
Instrument automatically and nondestructively monitors the quality of welds produced in microresistance welding. It measures the infrared energy generated in the weld as the weld is made and compares this energy with maximum and minimum limits of infrared energy values previously correlated with acceptable weld-strength tolerances.
Systematics in position annihilation lifetime analysis of high T c superconducting transitions
NASA Astrophysics Data System (ADS)
Howell, R. H.; Radousky, H. B.; Wachs, A. L.; Fluss, M. J.; Turchi, P. E. A.; Jean, Y. C.; Sundar, C. S.; Chu, C. W.; Peng, J. L.; Folkerts, T. J.; Shelton, R. N.; Hinks, D. G.
1989-12-01
Values of the positron lifetime have previously been observed to change with temperature below T c in high T c superconducting oxides. We report new measurements on Ba .6K .4BiO 3 and Nd 1.85Ce .15CuO 4.
Javiya, Umesh; Chew, John; Hills, Nick; Dullenkopf, Klaus; Scanlon, Timothy
2013-05-01
The prediction of the preswirl cooling air delivery and disk metal temperature are important for the cooling system performance and the rotor disk thermal stresses and life assessment. In this paper, standalone 3D steady and unsteady computation fluid dynamics (CFD), and coupled FE-CFD calculations are presented for prediction of these temperatures. CFD results are compared with previous measurements from a direct transfer preswirl test rig. The predicted cooling air temperatures agree well with the measurement, but the nozzle discharge coefficients are under predicted. Results from the coupled FE-CFD analyses are compared directly with thermocouple temperature measurements and with heat transfer coefficients on the rotor disk previously obtained from a rotor disk heat conduction solution. Considering the modeling limitations, the coupled approach predicted the solid metal temperatures well. Heat transfer coefficients on the rotor disk from CFD show some effect of the temperature variations on the heat transfer coefficients. Reasonable agreement is obtained with values deduced from the previous heat conduction solution.
Reassessing the ratio of glyoxal to formaldehyde as an indicator of hydrocarbon precursor speciation
NASA Astrophysics Data System (ADS)
Kaiser, J.; Wolfe, G. M.; Min, K. E.; Brown, S. S.; Miller, C. C.; Jacob, D. J.; deGouw, J. A.; Graus, M.; Hanisco, T. F.; Holloway, J.; Peischl, J.; Pollack, I. B.; Ryerson, T. B.; Warneke, C.; Washenfelder, R. A.; Keutsch, F. N.
2015-07-01
The yield of formaldehyde (HCHO) and glyoxal (CHOCHO) from oxidation of volatile organic compounds (VOCs) depends on precursor VOC structure and the concentration of NOx (NOx = NO + NO2). Previous work has proposed that the ratio of CHOCHO to HCHO (RGF) can be used as an indicator of precursor VOC speciation, and absolute concentrations of the CHOCHO and HCHO as indicators of NOx. Because this metric is measurable by satellite, it is potentially useful on a global scale; however, absolute values and trends in RGF have differed between satellite and ground-based observations. To investigate potential causes of previous discrepancies and the usefulness of this ratio, we present measurements of CHOCHO and HCHO over the southeastern United States (SE US) from the 2013 SENEX (Southeast Nexus) flight campaign, and compare these measurements with OMI (Ozone Monitoring Instrument) satellite retrievals. High time-resolution flight measurements show that high RGF is associated with monoterpene emissions, low RGF is associated with isoprene oxidation, and emissions associated with oil and gas production can lead to small-scale variation in regional RGF. During the summertime in the SE US, RGF is not a reliable diagnostic of anthropogenic VOC emissions, as HCHO and CHOCHO production are dominated by isoprene oxidation. Our results show that the new CHOCHO retrieval algorithm reduces the previous disagreement between satellite and in situ RGF observations. As the absolute values and trends in RGF observed during SENEX are largely reproduced by OMI observations, we conclude that satellite-based observations of RGF can be used alongside knowledge of land use as a global diagnostic of dominant hydrocarbon speciation.
Low LET radiolysis escape yields for reducing radicals and H2 in pressurized high temperature water
NASA Astrophysics Data System (ADS)
Sterniczuk, Marcin; Yakabuskie, Pamela A.; Wren, J. Clara; Jacob, Jasmine A.; Bartels, David M.
2016-04-01
Low Linear Energy Transfer (LET) radiolysis escape yields (G values) are reported for the sum (G(radH)+G(e-)aq) and for G(H2) in subcritical water up to 350 °C. The scavenger system 1-10 mM acetate/0.001 M hydroxide/0.00048 M N2O was used with simultaneous mass spectroscopic detection of H2 and N2 product. Temperature-dependent measurements were carried out with 2.5 MeV electrons from a van de Graaff accelerator, while room temperature calibration measurements were done with a 60Co gamma source. The concentrations and dose range were carefully chosen so that initial spur chemistry is not perturbed and the N2 product yield corresponds to those reducing radicals that escape recombination in pure water. In comparison with a recent review recommendation of Elliot and Bartels (AECL report 153-127160-450-001, 2009), the measured reducing radical yield is seven percent smaller at room temperature but in fairly good agreement above 150 °C. The H2 escape yield is in good agreement throughout the temperature range with several previous studies that used much larger radical scavenging rates. Previous analysis of earlier high temperature measurements of Gesc(radOH) is shown to be flawed, although the actual G values may be nearly correct. The methodology used in the present report greatly reduces the range of possible error and puts the high temperature escape yields for low-LET radiation on a much firmer quantitative foundation than was previously available.
NASA Astrophysics Data System (ADS)
Miyamoto, M.; Mikouchi, T.
1996-08-01
The oxygen fugacity of CO 2H 2 gas mixtures were measured with a ZrO 2 oxygen sensor at high temperatures in a furnace. We confirmed that the oxygen fugacity values measured by the ZrO 2 cell are more reducing than those of the CO 2H 2 gas mixtures calculated by using JANAF data at temperatures below 1150°C as was previously reported by Huebner (1975). We successfully decreased the deviation of the measured oxygen-fugacity value from the calculated one down to temperature of 800°C by using a Pt catalyst. Our results suggest that the deviation is probably due to incomplete equilibration of the gases.
Business owners' optimism and business performance after a natural disaster.
Bronson, James W; Faircloth, James B; Valentine, Sean R
2006-12-01
Previous work indicates that individuals' optimism is related to superior performance in adverse situations. This study examined correlations after flooding for measures of business recovery but found only weak support (very small common variance) for business owners' optimism scores and sales recovery. Using traditional measures of recovery, in this study was little empirical evidence that optimism would be of value in identifying businesses at risk after a natural disaster.
Real-ear-to-coupler difference predictions as a function of age for two coupling procedures.
Bagatto, Marlene P; Scollie, Susan D; Seewald, Richard C; Moodie, K Shane; Hoover, Brenda M
2002-09-01
The predicted real-ear-to-coupler difference (RECD) values currently used in pediatric hearing instrument prescription methods are based on 12-month age range categories and were derived from measures using standard acoustic immittance probe tips. Consequently, the purpose of this study was to develop normative RECD predicted values for foam/acoustic immittance tips and custom earmolds across the age continuum. To this end, RECD data were collected on 392 infants and children (141 with acoustic immittance tips, 251 with earmolds) to develop normative regression equations for use in deriving continuous age predictions of RECDs for foam/acoustic immittance tips and earmolds. Owing to the substantial between-subject variability observed in the data, the predictive equations of RECDs by age (in months) resulted in only gross estimates of RECD values (i.e., within +/- 4.4 dB for 95% of acoustic immittance tip measures; within +/- 5.4 dB in 95% of measures with custom earmolds) across frequency. Thus, it is concluded that the estimates derived from this study should not be used to replace the more precise individual RECD measurements. Relative to previously available normative RECD values for infants and young children, however, the estimates derived through this study provide somewhat more accurate predicted values for use under those circumstances for which individual RECD measurements cannot be made.
Pilot study of Iopamidol-based quantitative pH imaging on a clinical 3T MR scanner.
Müller-Lutz, Anja; Khalil, Nadia; Schmitt, Benjamin; Jellus, Vladimir; Pentang, Gael; Oeltzschner, Georg; Antoch, Gerald; Lanzman, Rotem S; Wittsack, Hans-Jörg
2014-12-01
The objective of this study was to show the feasibility to perform Iopamidol-based pH imaging via clinical 3T magnetic resonance imaging (MRI) using chemical exchange saturation transfer (CEST) imaging with pulse train presaturation. The pulse train presaturation scheme of a CEST sequence was investigated for Iopamidol-based pH measurements using a 3T magnetic resonance (MR) scanner. The CEST sequence was applied to eight tubes filled with 100-mM Iopamidol solutions with pH values ranging from 5.6 to 7.0. Calibration curves for pH quantification were determined. The dependence of pH values on the concentration of Iopamidol was investigated. An in vivo measurement was performed in one patient who had undergone a previous contrast-enhanced computed tomography (CT) scan with Iopamidol. The pH values of urine measured with CEST MRI and with a pH meter were compared. In the measured pH range, pH imaging using CEST imaging with pulse train presaturation was possible. Dependence between the pH value and the concentration of Iopamidol was not observed. In the in vivo investigation, the pH values in the human bladder measured by the Iopamidol CEST sequence and in urine were consistent. Our study shows the feasibility of using CEST imaging with Iopamidol for quantitative pH mapping in vitro and in vivo on a 3T MR scanner.
Determination of HART I Blade Structural Properties by Laboratory Testing
NASA Technical Reports Server (NTRS)
Jung, Sung N.; Lau, Benton H.
2012-01-01
The structural properties of higher harmonic Aeroacoustic Rotor Test (HART I) blades were measured using the original set of blades tested in the German-dutch wind tunnel (DNW) in 1994. the measurements include bending and torsion stiffness, geometric offsets, and mass and inertia properties of the blade. the measured properties were compared to the estimated values obtained initially from the blade manufacturer. The previously estimated blade properties showed consistently higher stiffness, up to 30 percent for the flap bending in the blade inboard root section.
Revised and extended analysis of the eighth spectrum of platinum (Pt VIII)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azarov, Vladimir I., E-mail: vlad_azarov@yahoo.com; Gayasov, Robert R.
2017-05-15
The spectrum of platinum was observed in the 300–2100 Å wavelength region. Grazing and normal incidence VUV spectrographs have been used to record the spectrum. The (5d{sup 3}+5d{sup 2}6s)−5d{sup 2}6p transition array of seven times ionized platinum, Pt VIII, has been investigated. The configurations 5d{sup 3} and 5d{sup 2}6p had been previously studied, and all levels of these configurations (19 and 45 levels, respectively) had been established. The previous analysis was based on 178 classified spectral lines. In the current analysis we have confirmed identification of all previously found levels and all but 10 previously assigned spectral lines, although we havemore » detected a large (up to 35 mÅ) systematic shift in wavelength measurements used in the previous analysis. Based on new wavelength measurements, we have corrected the 5d{sup 3} and 5d{sup 2}6p energy level values (by up to 55 cm{sup −1}) and established for the first time 14 out of 16 theoretically possible 5d{sup 2}6s levels in Pt VIII. The total list of identified lines (including 180 new lines) contains 349 entries. The orthogonal operators technique was used to calculate the level structure and transition probabilities. The energy parameters have been determined by the least squares fit to the observed levels. Calculated transition probability and energy values, as well as LS-compositions obtained from the fitted parameters are presented.« less
NASA Technical Reports Server (NTRS)
Zhang, Zhengyu; Kuo, Szu-Cherng; Klemm, R. Bruce; Monks, Paul S.; Stief, Louis J.
1994-01-01
Photoionization efficiency spectra of FO were measured over the wavelength range 80.0-100.0 nm and in the ionization threshold region, 94.0-100.0 nm, using a discharge flow-photoionization mass spectrometer apparatus coupled to a synchrotron radiation source. FO was generated by the reaction of F2P atoms with NO3 and via a F2O2 discharge. A value of 12.78 +/- 0.03 eV was obtained for the adiabatic ionization energy of FO from photoion thresholds which corresponds to FO(+)(X 3 Sigma -) from FO(X 2 Pi i). These results, which are the first to be obtained by direct Photo-ionization mass spectrometry (PIMS) measurements, corroborate those of a photoelectron spectroscopy (PES) study; however, the ionization energy determined here is free from interferences due to other species which complicated the PES measurement. A value of 109.5 +/- 8.0 kJ/mol for Delta f H 0 298(FO) is computed from the present value of IE(FO) and a previous appearance energy measurement, and a value for the proton affinity of FO is calculated to be 511.5 +/- 10.0 kJ/mol.
Sampling and storage of blood for pH and blood gas analysis.
Haskins, S C
1977-02-15
Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.
Wang, Ying; Johnson, John A.; Spinale, Francis G.; Sutton, Michael A.; Lessner, Susan M.
2014-01-01
The left anterior descending (LAD) coronary artery is the most frequently involved vessel in coronary artery dissection, a cause of acute coronary syndrome or sudden cardiac death. The biomechanical mechanisms underlying arterial dissection are not well understood. This study investigated the dissection properties of LAD specimens harvested from explanted hearts at the time of cardiac transplantation, from patients with primary dilated cardiomyopathy (n=12). Using a previously validated approach uniquely modified for these human LAD specimens, we quantified the local energy release rate, G, within different arterial layers during experimental dissection events (tissue tearing). Results show that the mean values of G during arterial dissection within the intima and within the media in human LADs are 20.7±16.5 J/m2 and 10.3±5.0 J/m2, respectively. The difference in dissection resistance between tearing events occurring within the intima and within the media is statistically significant. Our data fall in the same order of magnitude as most previous measurements of adhesive strength in other human arteries, with the differences in measured values of G within the layers most likely due to histologically observed differences in the structure and composition of arterial layers. PMID:24729631
Information and complexity measures in the interface of a metal and a superconductor
NASA Astrophysics Data System (ADS)
Moustakidis, Ch. C.; Panos, C. P.
2018-06-01
Fisher information, Shannon information entropy and Statistical Complexity are calculated for the interface of a normal metal and a superconductor, as a function of the temperature for several materials. The order parameter Ψ (r) derived from the Ginzburg-Landau theory is used as an input together with experimental values of critical transition temperature Tc and the superconducting coherence length ξ0. Analytical expressions are obtained for information and complexity measures. Thus Tc is directly related in a simple way with disorder and complexity. An analytical relation is found of the Fisher Information with the energy profile of superconductivity i.e. the ratio of surface free energy and the bulk free energy. We verify that a simple relation holds between Shannon and Fisher information i.e. a decomposition of a global information quantity (Shannon) in terms of two local ones (Fisher information), previously derived and verified for atoms and molecules by Liu et al. Finally, we find analytical expressions for generalized information measures like the Tsallis entropy and Fisher information. We conclude that the proper value of the non-extensivity parameter q ≃ 1, in agreement with previous work using a different model, where q ≃ 1.005.
Dollar$ & $en$e. Part V: What is your added value?
Wilkinson, I
2001-01-01
In Part I of this series, I introduced the concept of memes (1). Memes are ideas or concepts--the information world equivalent of genes. The goal of this series of articles is to infect you with memes, so that you will assimilate, translate, and express them. No matter what our area of expertise or "-ology," we all are in the information business. Our goal is to be in the wisdom business. In the previous papers in this series, I showed that when we convert raw data into wisdom we are moving along a value chain. Each step in the chain adds a different amount of value to the final product: timely, relevant, accurate, and precise knowledge that can be applied to create the ultimate product in the value chain: wisdom. In Part II of this series, I introduced a set of memes for measuring the cost of adding value (2). In Part III of this series, I presented a new set of memes for measuring the added value of knowledge, i.e., intellectual capital (3). In Part IV of this series, I discussed practical knowledge management tools for measuring the value of people, structural, and customer capital (4). In Part V of this series, I will apply intellectual capital and knowledge management concepts at the individual level, to help answer a fundamental question: What is my added value?
Measurement of low‐energy backscatter factors using GAFCHROMIC film and OSLDs
Elson, Howard R.; Lamba, Michael A. S.
2012-01-01
Some of the lowest voltages used in radiotherapy are termed Grenz and superficial X‐rays of ~ 20 and ~ 100 kVp, respectively. Dosimetrically, the surface doses from these beams are calculated with the use of a free in‐air air kerma measurement combined with a backscatter factor and the appropriate ratio of mass energy absorption coefficients from the measurement material to water. Alternative tools to the standard ion chamber for measuring the BSF are GAFCHROMIC EBT2 film and optically stimulated luminescent dosimeter (OSLD) crystals made from Al2O3. The scope of this project included making three different backscatter measurements with an Xstrahl‐D3100 X‐ray unit on the Grenz ray and superficial settings. These measurements were with OSLDs, GAFCHROMIC EBT2 film, and a PTW ionization chamber. The varied measurement methods allowed for intercomparison to determine the accuracy of the results. The ion chamber measurement was the least accurate, as expected from previous experimental findings. GAFCHROMIC EBT2 film proved to be a useful tool which gave reasonable results, and Landauer OSLDs showed good results for smaller field sizes and an increasing overresponse with larger fields. The specific backscatter factors for this machine demonstrated values about 5% higher than the universal values suggested by the AAPM and IPEMB codes of practice for the 100 kVp setting. The 20 kvp measured data from both techniques showed general agreement with those found in the BJR Supplement No. 10, indicating that this unit's Grenz ray spectrum is similar to those used in previous experimental work. PACS number: 87.53.Bn PMID:23149776
Wess, G; Mäurer, J; Simak, J; Hartmann, K
2010-01-01
M-mode is the echocardiographic gold standard to diagnose dilated cardiomyopathy (DCM) in dogs, whereas Simpson's method of discs (SMOD) is the preferred method to detect echocardiographic evidence of disease in humans. To establish reference values for SMOD and to compare those with M-mode measurements. Nine hundred and sixty-nine examinations of 471 Doberman Pinschers. Using a prospective longitudinal study design. Reference values for SMOD were established using 75 healthy Doberman Pinschers >8 years old with <50 ventricular premature contractions (VPCs) in 24 hours. The ability of the new SMOD cut-off values, normalized to body surface area (BSA), for left ventricular end-diastolic volume (LVEDV/BSA >95mL/m(2) ) and end-systolic volume (LVESV/BSA > 55mL/m(2) ) to detect echocardiographic changes in Doberman Pinschers with DCM was compared with currently recommended M-mode values. Dogs with elevated SMOD values but normal M-mode measurements were followed-up using a prospective longitudinal study design. At the final examination 175 dogs were diagnosed with DCM according to both methods (M-mode and SMOD). At previous examinations, M-mode values were abnormal in 142 examinations only, whereas all 175 SMOD already had detected changes. Additionally, 19 of 154 dogs with >100 VPCs/24 hours and normal M-mode values had abnormal SMOD measurement. Six dogs with increased SMOD measurements remained healthy at several follow-up examinations (classified as false positive); in 24 dogs with increased SMOD measurements, no follow-up examinations were available (classified as unclear). SMOD measurements are superior to M-mode to detect early echocardiographic changes in Dobermans with occult DCM. Copyright © 2010 by the American College of Veterinary Internal Medicine.
Measurement of the profile and intensity of the solar He I lambda 584-A resonance line
NASA Technical Reports Server (NTRS)
Maloy, J. O.; Hartmann, U. G.; Judge, D. L.; Carlson, R. W.
1978-01-01
The intensity and profile of the helium resonance line at 584 A from the entire disk of the sun was investigated by using a rocket-borne helium-filled spectrometer and a curve-of-growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 + or - 10 mA, while the integrated intensity was measured to be 2.6 + or - 1.3 billion photons/s per sq cm at solar activity levels of F(10.7) = 90.8 x 10 to the -22nd per sq m/Hz and Rz = 27. The measured line width is in good agreement with previous spectrographic measurements, but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of 20 + or - 10 billion photons/s per sq cm/A is in good agreement with values inferred from airglow measurements.
ELECTRON IONIZATION FREQUENCY IN HYDROGEN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cottingham, W.B.; Buchsbaum, S.J.
1963-05-01
The frequency of ionization by electrons in hydrogen was measured during pulsed microwave breakdown in a waveguide. Optical radiation emanating from the plasma was used to determine the temporal rate of growth of electron density. Values of the ionization frequency are presented as a function of E/sub e//p/sub o/ for 36 < E/sub e//p/sub o/ < 200 v/cm-mm Hg. The measurements constitute an extension of the work of Madan, Gordon, Buchsbaum, and Brown who measured this coefficient up to an E/sub e//p/sub o/ of 40 v/cm-mm Hg by microwave cavity techniques. Comparison is made with previous d-c measurements of Rosemore » and with the theory of Allis and Brown. Good agreement is obtained with the measurements of Rose but not with the theory of Allis and Brown extended to high E/sub e//p/ sub o/, nor with the previous microwave measurements of Madan et al. (auth)« less
Vortex wakes generated by robins Erithacus rubecula during free flight in a wind tunnel
Hedenström, A; Rosén, M; Spedding, G.R
2005-01-01
The wakes of two individual robins were measured in digital particle image velocimetry (DPIV) experiments conducted in the Lund wind tunnel. Wake measurements were compared with each other, and with previous studies in the same facility. There was no significant individual variation in any of the measured quantities. Qualitatively, the wake structure and its gradual variation with flight speed were exactly as previously measured for the thrush nightingale. A procedure that accounts for the disparate sources of circulation spread over the complex wake structure nevertheless can account for the vertical momentum flux required to support the weight, and an example calculation is given for estimating drag from the components of horizontal momentum flux (whose net value is zero). The measured circulations of the largest structures in the wake can be predicted quite well by simple models, and expressions are given to predict these and other measurable quantities in future bird flight experiments. PMID:16849236
Fuller, L.M.; Jodoin, R.S.; Minnerick, R.J.
2011-01-01
Inland lakes are an important economic and environmental resource for Michigan. The U.S. Geological Survey and the Michigan Department of Natural Resources and Environment have been cooperatively monitoring the quality of selected lakes in Michigan through the Lake Water Quality Assessment program. Sampling for this program began in 2001; by 2010, 730 of Michigan’s 11,000 inland lakes are expected to have been sampled once. Volunteers coordinated by the Michigan Department of Natural Resources and Environment began sampling lakes in 1974 and continue to sample (in 2010) approximately 250 inland lakes each year through the Michigan Cooperative Lakes Monitoring Program. Despite these sampling efforts, it still is impossible to physically collect measurements for all Michigan inland lakes; however, Landsat-satellite imagery has been used successfully in Minnesota, Wisconsin, Michigan, and elsewhere to predict the trophic state of unsampled inland lakes greater than 20 acres by producing regression equations relating in-place Secchi-disk measurements to Landsat bands. This study tested three alternatives to methods previously used in Michigan to improve results for predicted statewide Trophic State Index (TSI) computed from Secchi-disk transparency (TSI (SDT)). The alternative methods were used on 14 Landsat-satellite scenes with statewide TSI (SDT) for two time periods (2003– 05 and 2007–08). Specifically, the methods were (1) satellitedata processing techniques to remove areas affected by clouds, cloud shadows, haze, shoreline, and dense vegetation for inland lakes greater than 20 acres in Michigan; (2) comparison of the previous method for producing a single open-water predicted TSI (SDT) value (which was based on an area of interest (AOI) and lake-average approach) to an alternative Gethist method for identifying open-water areas in inland lakes (which follows the initial satellite-data processing and targets the darkest pixels, representing the deepest water, before regression equations are created); and (3) checking to see whether the predicted TSI (SDT) values compared well between two regression equations, one previously used in Michigan and an alternative equation from the hydrologic literature. The combination of improved satellite-data processing techniques and the Gethist method to identify open-water areas in inland lakes during 2003–05 and 2007–08 provided a stronger relation and statistical significance between predicted TSI (SDT) and measured TSI than did the AOI lake-average method; differences in results for the two methods were significant at the 99-percent confidence level. With regard to the comparison of the regression equations, there were no statistically significant differences at the 95-percent confidence level between results from the two equations. The previously used equation, in combination with the Gethist method, yielded coefficient of determination (R2) values of 0.71 and 0.77 for the periods 2003–05 and 2007–08, respectively. The alternative equation, in combination with the Gethist method, yielded R2 values of 0.74 and 0.75 for 2003–05 and 2007–08, respectively. Predicted TSI (SDT) and measured TSI (SDT) values for lakes used in the regression equations compared well, with R2 values of 0.95 and 0.96 for predicted TSI (SDT) for 2003–05 and 2007–08, respectively. The R2 values for statewide predicted TSI (SDT) for all inland lakes with available open-water areas for 2003–05 and 2007–08 were 0.91 and 0.93, respectively. Although the two equations predicted similar trophic-state classes, the alternative equation is planned to be used for future prediction of TSI (SDT) values for Michigan inland lakes, to promote consistency in comparing predicted values between States and for potential use in trend analysis.
Total cross sections for ultracold neutrons scattered from gases
Seestrom, Susan Joyce; Adamek, Evan R.; Barlow, Dave; ...
2017-01-30
Here, we have followed up on our previous measurements of upscattering of ultracold neutrons (UCNs) from a series of gases by making measurements of total cross sections on the following gases hydrogen, ethane, methane, isobutene, n-butane, ethylene, water vapor, propane, neopentane, isopropyl alcohol, and 3He. The values of these cross sections are important for estimating the loss rate of trapped neutrons due to residual gas and are relevant to neutron lifetime measurements using UCNs. The effects of the UCN velocity and path-length distributions were accounted for in the analysis using a Monte Carlo transport code. Results are compared to ourmore » previous measurements and with the known absorption cross section for 3He scaled to our UCN energy. We find that the total cross sections for the hydrocarbon gases are reasonably described by a function linear in the number of hydrogen atoms in the molecule.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seestrom, Susan Joyce; Adamek, Evan R.; Barlow, Dave
Here, we have followed up on our previous measurements of upscattering of ultracold neutrons (UCNs) from a series of gases by making measurements of total cross sections on the following gases hydrogen, ethane, methane, isobutene, n-butane, ethylene, water vapor, propane, neopentane, isopropyl alcohol, and 3He. The values of these cross sections are important for estimating the loss rate of trapped neutrons due to residual gas and are relevant to neutron lifetime measurements using UCNs. The effects of the UCN velocity and path-length distributions were accounted for in the analysis using a Monte Carlo transport code. Results are compared to ourmore » previous measurements and with the known absorption cross section for 3He scaled to our UCN energy. We find that the total cross sections for the hydrocarbon gases are reasonably described by a function linear in the number of hydrogen atoms in the molecule.« less
Air Pollution Potential from Electroplating Operations.
ERIC Educational Resources Information Center
Diamond, Philip
Measurements were made of emission rates from electroplating operations considered to have maximum air pollution potential. Sampling was performed at McClellan and additional data from a previous survey at Hill Air Force Base was used. Values obtained were extremely low. Based on existing Federal standards, no collectors are specifically required…
Understanding Physical Educators' Perceptions of Mattering Questionnaire--Physical Education
ERIC Educational Resources Information Center
Richards, K. Andrew R.; Gaudreault, Karen Lux; Woods, Amelia Mays
2017-01-01
Previous research has illustrated that physical educators feel their subject is valued less than others in the context of schools. However, to date, no instruments have been developed to measure physical education teachers' perceptions of mattering. This study sought to propose and validate the Perceived Mattering Questionnaire--Physical Education…
ERIC Educational Resources Information Center
Nieuwland, Mante S.
2016-01-01
Do negative quantifiers like "few" reduce people's ability to rapidly evaluate incoming language with respect to world knowledge? Previous research has addressed this question by examining whether online measures of quantifier comprehension match the "final" interpretation reflected in verification judgments. However, these…
40 CFR 86.130-00 - Test sequence; general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... measurements supersede previous values. [61 FR 54893, Oct. 22, 1996] ... PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission... (US06) and air conditioning (SC03) use are conducted as stand-alone tests as described in §§ 86.158-00...
Pressure Probe and Isopiestic Psychrometer Measure Similar Turgor 1
Nonami, Hiroshi; Boyer, John S.; Steudle, Ernst
1987-01-01
Turgor measured with a miniature pressure probe was compared to that measured with an isopiestic thermocouple psychrometer in mature regions of soybean (Glycine max [L.] Merr.) stems. The probe measured turgor directly in cells of intact stems whereas the psychrometer measured the water potential and osmotic potential of excised stem segments and turgor was calculated by difference. When care was taken to prevent dehydration when working with the pressure probe, and diffusive resistance and dilution errors with the psychrometer, both methods gave similar values of turgor whether the plants were dehydrating or rehydrating. This finding, together with the previously demonstrated similarity in turgor measured with the isopiestic psychrometer and a pressure chamber, indicates that the pressure probe provides accurate measurements of turgor despite the need to penetrate the cell. On the other hand, it suggests that as long as precautions are taken to obtain accurate values for the water potential and osmotic potential, turgor can be determined by isopiestic psychrometry in tissues not accessible to the pressure probe for physical reasons. PMID:16665293
Pressure probe and isopiestic psychrometer measure similar turgor.
Nonami, H; Boyer, J S; Steudle, E
1987-03-01
Turgor measured with a miniature pressure probe was compared to that measured with an isopiestic thermocouple psychrometer in mature regions of soybean (Glycine max [L.] Merr.) stems. The probe measured turgor directly in cells of intact stems whereas the psychrometer measured the water potential and osmotic potential of excised stem segments and turgor was calculated by difference. When care was taken to prevent dehydration when working with the pressure probe, and diffusive resistance and dilution errors with the psychrometer, both methods gave similar values of turgor whether the plants were dehydrating or rehydrating. This finding, together with the previously demonstrated similarity in turgor measured with the isopiestic psychrometer and a pressure chamber, indicates that the pressure probe provides accurate measurements of turgor despite the need to penetrate the cell. On the other hand, it suggests that as long as precautions are taken to obtain accurate values for the water potential and osmotic potential, turgor can be determined by isopiestic psychrometry in tissues not accessible to the pressure probe for physical reasons.
Critical laboratory values in hemostasis: toward consensus.
Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J
2017-09-01
The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.
Empathy, values, morality and Asperger's syndrome.
Hirvelä, Shari; Helkama, Klaus
2011-12-01
The aims of this study were, first, to re-address the issue of empathy among people with autism conditions; second, to explore the relationships between empathy and values among autistic populations and controls; and third, to explore the capacity for moral agency among those affected by autism. We compared responses of an Asperger group (N = 41) and a control group (N = 139) to measures of self-reported empathy (Davis's IRI) and value priorities (Schwartz's PVQ). Control group results were largely in line with previous studies, such that empathy subscales of perspective taking and empathic concern showed their strongest positive and negative relations to the Schwartz self-transcendence/self-enhancement dimensions. Results for the Asperger group showed that although on the one hand there were self-reported difficulties in perspective taking and the cognitive recognition of affect, and that on the other hand there were less connections between the empathy and value measures, there was nevertheless a comparable prioritization of moral values. Conclusions suggest that different people may acquire moral values through different mechanisms. © 2011 The Authors. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.
Sonawane, A U; Shirva, V K; Pradhan, A S
2010-02-01
Skin entrance doses (SEDs) were estimated by carrying out measurements of air kerma from 101 X-ray machines installed in 45 major and selected hospitals in the country by using a silicon detector-based dose Test-O-Meter. 1209 number of air kerma measurements of diagnostic projections for adults have been analysed for seven types of common diagnostic examinations, viz. chest (AP, PA, LAT), lumbar spine (AP, LAT), thoracic spine (AP, LAT), abdomen (AP), pelvis (AP), hip joints (AP) and skull (PA, LAT) for different film-screen combinations. The values of estimated diagnostic reference levels (DRLs) (third quartile values of SEDs) were compared with guidance levels/DRLs of doses published by the IAEA-BSS-Safety Series No. 115, 1996; HPA (NRPB) (2000 and 2005), UK; CRCPD/CDRH (USA), European Commission and other national values. The values of DRLs obtained in this study are comparable with the values published by the IAEA-BSS-115 (1996); HPA (NRPB) (2000 and 2005) UK; EC and CRCPD/CDRH, USA including values obtained in previous studies in India.
Heat-transfer measurements of the 1983 Kilauea lava flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardee, H.C.
1983-10-07
Convective heat flow measurements of a basaltic lava flow were made during the 1983 eruption of Kilauea volcano in Hawaii. Eight field measurements of induced natural convection were made, giving heat flux values that ranged from 1.78 to 8.09 kilowatts per square meter at lava temperatures of 1088 and 1128 degrees Celsius, respectively. These field measurements of convective heat flux at subliquidus temperatures agree with previous laboratory measurements in furnace-melted samples of molten lava, and are useful for predicting heat transfer in magma bodies and for estimating heat extraction rates for magma energy.
Heat transfer measurements of the 1983 kilauea lava flow.
Hardee, H C
1983-10-07
Convective heat flow measurements of a basaltic lava flow were made during the 1983 eruption of Kilauea volcano in Hawaii. Eight field measurements of induced natural convection were made, giving heat flux values that ranged from 1.78 to 8.09 kilowatts per square meter at lava temperatures of 1088 and 1128 degrees Celsius, respectively. These field measurements of convective heat flux at subliquidus temperatures agree with previous laboratory measurements in furnace-melted samples of molten lava, and are useful for predicting heat transfer in magma bodies and for estimating heat extraction rates for magma energy.
The Lamb shift in muonic hydrogen and the proton radius
NASA Astrophysics Data System (ADS)
Antognini, A.; Pohl, R.; Amaro, F. D.; Biraben, F.; Cardoso, J. M. R.; Covita, D. S.; Dax, A.; Dhawan, S.; Fernandes, L. M. P.; Giesen, A.; Gouvea, A. L.; Graf, T.; Ḧansch, T. W.; Hildebrandt, M.; Indelicato, P.; Julien, L.; Kao, C.-Y.; Kirch, K.; Knowles, P.; Le Bigot, E.-O.; Liu, Y.-W.; Lopes, J. A. M.; Ludhova, L.; Monteiro, C. M. B.; Mulhauser, F.; Nebel, T.; Nez, F.; Rabinowitz, P.; dos Santos, J. M. F.; Schaller, L. A.; Schuhmann, K.; Schwob, C.; Taqqu, D.; Veloso, J. F. C. A.; Voss, A.; Kottmann, F.
By means of pulsed laser spectroscopy applied to muonic hydrogen (μ- p) we have measured the 2S F = 1 1/2 - 2PF = 2 3/2 transition frequency to be 49881.88(76) GHz. By comparing this measurement with its theoretical prediction based on bound-state QED we have determined a proton radius value of rp = 0.84184 (67) fm. This new value is an order of magnitude preciser than previous results but disagrees by 5 standard deviations from the CODATA and the electronproton scattering values. An overview of the present effort attempting to solve the observed discrepancy is given. Using the measured isotope shift of the 1S-2S transition in regular hydrogen and deuterium also the rms charge radius of the deuteron rd = 2.12809 (31) fm has been determined. Moreover we present here the motivations for the measurements of the μ 4He + and μ 3He + 2S-2P splittings. The alpha and triton charge radii are extracted from these measurements with relative accuracies of few 10 - 4. Measurements could help to solve the observed discrepancy, lead to the best test of hydrogen-like energy levels and provide crucial tests for few-nucleon ab-initio theories and potentials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.
2016-10-24
SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The total uranium in the Tank 38H surface sample was 57.6 mg/L, while the sub-surface sample was 106 mg/L. The Tank 43H samples ranged from 50.0 to 51.9 mg/L total uranium. The U-235 percentage was consistent for all four samples at 0.62%. The total uranium and percent U-235 results appear consistent with recent Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and somewhat higher concentrations than previous samples. The Pu-238 concentrationmore » is more than forty times higher in the Tank 38H sub-surface sample than the surface sample. The surface and sub-surface Tank 43H samples contain similar plutonium concentrations and are within the range of values measured on previous samples. The four samples analyzed show silicon concentrations somewhat higher than the previous sample with values ranging from 104 to 213 mg/L.« less
Estimating new production in the equatorial Pacific Ocean at 150 deg W
NASA Technical Reports Server (NTRS)
Dugdale, Richard C.; Wilkerson, Frances P.; Barber, Richard T.; Chavez, Francisco P.
1992-01-01
A major goal of the WEC88 cruise of the R/V Wecoma to the equatorial Pacific (made in February-March 1988) was to establish rates of new production along a meridional section at 150 deg W and to compare these measured rates with the relatively high values for the equatorial Pacific that had been reported previously using indirect methods and models. Production values were obtained from the traditional approach using N-15 labeled nitrate uptake, and by using C-14 fixation values multiplied by f (proportion of new production) from various sources: from N-15 data, from a C-14 fixation-versus-f relationship, or from a nitrate-versus-f relationship. The ratios of directly measured nitrate and carbon uptake and the ratios of nitrate to nitrate plus ammonium uptake, i.e., values of f, agree well; values of f calculated from carbon uptake or from nitrate concentration are overestimates for the equatorial upwelling region. Carbon-to-nitrogen uptake ratios measured with C-14 and N-15, respectively, approximate the Redfield molar ratio, 6.6 C:N. The overall mean value of f (0.17) helps confirm the view that the low primary production in the enriched eastern equatorial Pacific is due to failure of the nitrate-uptake system.
Electrical properties of lunar soil dependence on frequency, temperature and moisture.
NASA Technical Reports Server (NTRS)
Strangway, D. W.; Chapman, W. B.; Olhoeft, G. R.; Carnes, J.
1972-01-01
It was found that the dielectric constant and loss tangent of lunar soil samples in the range from 100 Hz to 1 MHz are not strongly dependent on frequency provided care is taken to avoid exposure of the sample to atmospheric air containing moisture. The loss tangent value obtained is lower by nearly a factor 10 than any previously reported value. The measurement data imply that the surface layers of the moon are probably extremely transparent to radiowaves.
Large magnetic entropy change in multiferroic HoFeO3 single crystal
NASA Astrophysics Data System (ADS)
Das, Moumita; Mandal, Prabhat
2018-04-01
In this article magnetic and magnetocaloric properties of HoFeO3 single crystal have been investigated by magnetization measurement in the temperature range 6-30K and near spin reorientation transition (TSR) region 45-61K. Remarkably large and reversible magnetic entropy change (-ΔSm) = 27J/kg K, has been observed for a field change of 0-6T near 9.5K due to metamagnetic transition. The value of ΔSm is 6J/kg K at 6T near TSR. This magnetocaloric parameter is larger than previously reported value along [100] crystallographic axis due to its anisotropic nature along different axis. This value is larger than some of the potential magnetic refrigerants in the same temperature range which is not reported previously. The ΔSm is also quite large for a small and moderate field change. For an example the values of ΔSmax are 7 and 12 J/kg K for field change of 2 and 3T. The large value of this magnetocaloric parameter suggests that HoFeO3 could be considered as a potential refrigerant material for low-temperature magnetic refrigeration technology to liquefaction the hydrogen and helium in fuel industry.
Mansoor, Kanaan; Shahnawaz, Saba; Rasool, Mariam; Chaudhry, Huwad; Ahuja, Gul; Shahnawaz, Sara
2016-09-15
Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard, the ongoing deliberation as to whether mercury sphygmomanometers should be replaced with the automated oscillometric devices stems from the risk mercury poses to the environment. This study was performed to check the validity of automated oscillometric blood pressure measurements as compared to the manual blood pressure measurements in Karachi, Pakistan. Blood pressure was recorded in 200 individuals aged 15 and above using both, an automated oscillometric blood pressure device (Dinamap Procare 100) and a manual mercury sphygmomanometer concomitantly. Two nurses were assigned to each patient and the device, arm for taking the reading and nurses were randomly determined. SPSS version 20 was used for analysis. Mean and standard deviation of the systolic and diastolic measurements from each modality were compared to each other and P values of 0.05 or less were considered to be significant. Validation criteria of British Hypertension Society (BHS) and the US Association for the Advancement of Medical Instrumentation (AAMI) were used. Two hundred patients were included. The mean of the difference of systolic was 8.54 ± 9.38 while the mean of the difference of diastolic was 4.21 ± 7.88. Patients were further divided into three groups of different systolic blood pressure <= 120, > 120 to = 150 and > 150, their means were 6.27 ± 8.39 (p-value 0.175), 8.91 ± 8.96 (p-value 0.004) and 10.98 ± 10.49 (p-value 0.001) respectively. In our study 89 patients were previously diagnosed with hypertension; their difference of mean systolic was 9.43 ± 9.89 (p-value 0.000) and difference of mean diastolic was 4.26 ± 7.35 (p-value 0.000). Systolic readings from a previously validated device are not reliable when used in the ER and they show a higher degree of incongruency and inaccuracy when they are used outside validation settings. Also, readings from the right arm tend to be more precise.
Interoceptive ability predicts aversion to losses
Sokol-Hessner, Peter; Hartley, Catherine A; Hamilton, Jeffrey R.
2014-01-01
Emotions have been proposed to inform risky decision-making through the influence of affective physiological responses on subjective value. The ability to perceive internal body states, or “interoception” may influence this relationship. Here, we examined whether interoception predicts participants' degree of loss aversion, which has been previously linked to choice-related arousal responses. Participants performed both a heartbeat detection task indexing interoception and a risky monetary decision-making task, from which loss aversion, risk attitudes, and choice consistency were parametrically measured. Interoceptive ability correlated selectively with loss aversion, and was unrelated to the other value parameters. This finding suggests that specific and separable component processes underlying valuation are shaped not only by our physiological responses, as shown in previous findings, but also by our interoceptive access to such signals. PMID:24916358
A new NIST primary standardization of 18F.
Fitzgerald, R; Zimmerman, B E; Bergeron, D E; Cessna, J C; Pibida, L; Moreira, D S
2014-02-01
A new primary standardization of (18)F by NIST is reported. The standard is based on live-timed beta-gamma anticoincidence counting with confirmatory measurements by three other methods: (i) liquid scintillation (LS) counting using CIEMAT/NIST (3)H efficiency tracing; (ii) triple-to-double coincidence ratio (TDCR) counting; and (iii) NaI integral counting and HPGe γ-ray spectrometry. The results are reported as calibration factors for NIST-maintained ionization chambers (including some "dose calibrators"). The LS-based methods reveal evidence for cocktail instability for one LS cocktail. Using an ionization chamber to link this work with previous NIST results, the new value differs from the previous reports by about 4%, but appears to be in good agreement with the key comparison reference value (KCRV) of 2005. © 2013 Published by Elsevier Ltd.
Zhu, Zhen; Puliga, Michelangelo; Cerina, Federica; Chessa, Alessandro; Riccaboni, Massimo
2015-01-01
The fragmentation of production across countries has become an important feature of the globalization in recent decades and is often conceptualized by the term “global value chains” (GVCs). When empirically investigating the GVCs, previous studies are mainly interested in knowing how global the GVCs are rather than how the GVCs look like. From a complex networks perspective, we use the World Input-Output Database (WIOD) to study the evolution of the global production system. We find that the industry-level GVCs are indeed not chain-like but are better characterized by the tree topology. Hence, we compute the global value trees (GVTs) for all the industries available in the WIOD. Moreover, we compute an industry importance measure based on the GVTs and compare it with other network centrality measures. Finally, we discuss some future applications of the GVTs. PMID:25978067
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; ...
2014-07-31
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), organic mass-to-organic carbon (OM : OC), and carbon oxidation state (OS C) for a vastly expanded laboratory dataset of multifunctional oxidized OA standards. For the expanded standard dataset, the "Aiken-Explicit" method (Aiken et al., 2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios, reproduces known molecular Omore » : C and H : C ratio values within 20% (average absolute value of relative errors) and 12% respectively. The more commonly used "Aiken-Ambient" method, which uses empirically estimated H 2O + and CO + ion intensities to avoid gas phase air interferences at these ions, reproduces O : C and H : C of multifunctional oxidized species within 28% and 14% of known values. These values are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2O +, CO +, and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and H 2O + produced from many oxidized species. Combined AMS-vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method reduces the systematic biases and reproduces O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C and H : C values is smaller (12% and 4% respectively) for synthetic mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.« less
Velocity diagnostics of electron beams within a 140 GHz gyrotron
NASA Astrophysics Data System (ADS)
Polevoy, Jeffrey Todd
1989-06-01
Experimental measurements of the average axial velocity v(sub parallel) of the electron beam within the M.I.T. 140 GHz MW gyrotron have been performed. The method involves the simultaneous measurement of the radial electrostatic potential of the electron beam V(sub p) and the beam current I(sub b). The V(sub p) is measured through the use of a capacitive probe installed near or within the gyrotron cavity, while I(sub b) is measured with a previously installed Rogowski coil. Three capacitive probes have been designed and built, and two have operated within the gyrotron. The probe results are repeatable and consistent with theory. The measurements of v(sub parallel) and calculations of the corresponding transverse to longitudinal beam velocity ratio (alpha) = v(sub perpendicular)/v(sub parallel) at the cavity have been made at various gyrotron operation parameters. These measurements will provide insight into the causes of discrepancies between theoretical RF interaction efficiencies and experimental efficiencies obtained in experiments with the M.I.T. 140 GHz MW gyrotron. The expected values of v(sub parallel) and (alpha) are determined through the use of a computer code (EGUN) which is used to model the cathode and anode regions of the gyrotron. It also computes the trajectories and velocities of the electrons within the gyrotron. There is good correlation between the expected and measured values of (alpha) at low (alpha), with the expected values from EGUN often falling within the standard errors of the measured values.
VizieR Online Data Catalog: Abundance of nine beta Cephei stars (Morel+, 2006)
NASA Astrophysics Data System (ADS)
Morel, T.; Butler, K.; Aerts, C.; Neiner, C.; Briquet, M.
2006-07-01
The equivalent widths (EWs) were measured on high-resolution spectra obtained with various echelle spectrographs (see Table 2 of paper for further details). Our EWs are systematically larger than the values quoted by Gies & Lambert (1992ApJ...387..673G) for the seven stars in common, but a similar trend is evident when comparing their values with previous measurements in the literature (see their Fig.4). This is likely to result from their use of Gaussian fitting instead of the direct integration used in our case. The same conclusion holds for the EWs of xi1 CMa presented by Hambly et al. (1996MNRAS.278..811H). (1 data file).
Heat transfer and fluid mechanics measurements in transitional boundary layer flows
NASA Technical Reports Server (NTRS)
Wang, T.; Simon, T. W.; Buddhavarapu, J.
1985-01-01
Experimental results are presented to document hydrodynamic and thermal development of flat-plate boundary layers undergoing natural transition. Local heat transfer coefficients, skin friction coefficients and profiles of velocity, temperature and Reynolds normal and shear stresses are presented. A case with no transition and transitional cases with 0.68% and 2.0% free-stream disturbance intensities were investigated. The locations of transition are consistent with earlier data. A late-laminar state with significant levels of turbulence is documented. In late-transitional and early-turbulent flows, turbulent Prandtl number and conduction layer thickness values exceed, and the Reynolds analogy factor is less than, values previously measured in fully turbulent flows.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barker, L.M.; Jones, A.H.
1986-04-01
The fracture toughness of CIP-HIP (cold isostatic pressed-hot isostatic pressed) beryllium was determined using the short-bar fracture-toughness (K/sub IcSB/) method. The K/sub IcSB/ value measured was 10.96 MPa x the square root of m at room temperature. This falls well within the expected range of 9 to 12 MPa x the square root of m as observed from previous fracture toughness measurements of beryllium. Toughness increased rapidly between 400 F and 500 F reaching a value of 16.7 MPa x the square root of m at 500 F.
NASA Astrophysics Data System (ADS)
Pavone, F. S.; Marin, F.; de Natale, P.; Inguscio, M.; Biraben, F.
1994-07-01
The 23S1-33P40He transition at λ0=389 nm is measured with respect to a previously frequency calibrated 87Rb two-photon transition at 2λ0=778 nm. The 4He absolute frequency is 770 732 839 058 (190) kHz, with an accuracy of 2.4 parts in 1010. A Lamb shift value of +4057.61 (79) MHz, with 600 kHz uncertainty arising from the theoretical position of the 33P0 energy level, is extracted for the 23S1 level. This value is more than 2 orders of magnitude more accurate than the current best theoretical predictions.
Black, A E
2000-09-01
To re-state the principles underlying the Goldberg cut-off for identifying under-reporters of energy intake, re-examine the physiological principles and update the values to be substituted into the equation for calculating the cut-off, and to examine its use and limitations. New values are suggested for each element of the Goldberg equation. The physical activity level (PAL) for comparison with energy intake:basal metabolic rate (EI:BMR) should be selected to reflect the population under study; the PAL value of 1.55 x BMR is not necessarily the value of choice. The suggested value for average within-subject variation in energy intake is 23% (unchanged), but other sources of variation are increased in the light of new data. For within-subject variation in measured and estimated BMR, 4% and 8.5% respectively are suggested (previously 2.5% and 8%), and for total between-subject variation in PAL, the suggested value is 15% (previously 12.5%). The effect of these changes is to widen the confidence limits and reduce the sensitivity of the cut-off. The Goldberg cut-off can be used to evaluate the mean population bias in reported energy intake, but information on the activity or lifestyle of the population is needed to choose a suitable PAL energy requirement for comparison. Sensitivity for identifying under-reporters at the individual level is limited. In epidemiological studies information on home, leisure and occupational activity is essential in order to assign subjects to low, medium or high PAL levels before calculating the cut-offs. In small studies, it is desirable to measure energy expenditure, or to calculate individual energy requirements, and to compare energy intake directly with energy expenditure.
Quantitative and descriptive comparison of four acoustic analysis systems: vowel measurements.
Burris, Carlyn; Vorperian, Houri K; Fourakis, Marios; Kent, Ray D; Bolt, Daniel M
2014-02-01
This study examines accuracy and comparability of 4 trademarked acoustic analysis software packages (AASPs): Praat, WaveSurfer, TF32, and CSL by using synthesized and natural vowels. Features of AASPs are also described. Synthesized and natural vowels were analyzed using each of the AASP's default settings to secure 9 acoustic measures: fundamental frequency (F0), formant frequencies (F1-F4), and formant bandwidths (B1-B4). The discrepancy between the software measured values and the input values (synthesized, previously reported, and manual measurements) was used to assess comparability and accuracy. Basic AASP features are described. Results indicate that Praat, WaveSurfer, and TF32 generate accurate and comparable F0 and F1-F4 data for synthesized vowels and adult male natural vowels. Results varied by vowel for women and children, with some serious errors. Bandwidth measurements by AASPs were highly inaccurate as compared with manual measurements and published data on formant bandwidths. Values of F0 and F1-F4 are generally consistent and fairly accurate for adult vowels and for some child vowels using the default settings in Praat, WaveSurfer, and TF32. Manipulation of default settings yields improved output values in TF32 and CSL. Caution is recommended especially before accepting F1-F4 results for children and B1-B4 results for all speakers.
A study on the measurement of wrist motion range using the iPhone 4 gyroscope application.
Kim, Tae Seob; Park, David Dae Hwan; Lee, Young Bae; Han, Dong Gil; Shim, Jeong Su; Lee, Young Jig; Kim, Peter Chan Woo
2014-08-01
Measuring the range of motion (ROM) of the wrist is an important physical examination conducted in the Department of Hand Surgery for the purpose of evaluation, diagnosis, prognosis, and treatment of patients. The most common method for performing this task is by using a universal goniometer. This study was performed using 52 healthy participants to compare wrist ROM measurement using a universal goniometer and the iPhone 4 Gyroscope application. Participants did not have previous wrist illnesses and their measured values for wrist motion were compared in each direction. Normal values for wrist ROM are 73 degrees of flexion, 71 degrees of extension, 19 degrees of radial deviation, 33 degrees of ulnar deviation, 140 degrees of supination, and 60 degrees of pronation.The average measurement values obtained using the goniometer were 74.2 (5.1) degrees for flexion, 71.1 (4.9) degrees for extension, 19.7 (3.0) degrees for radial deviation, 34.0 (3.7) degrees for ulnar deviation, 140.8 (5.6) degrees for supination, and 61.1 (4.7) degrees for pronation. The average measurement values obtained using the iPhone 4 Gyroscope application were 73.7 (5.5) degrees for flexion, 70.8 (5.1) degrees for extension, 19.5 (3.0) degrees for radial deviation, 33.7 (3.9) degrees for ulnar deviation, 140.4 (5.7) degrees for supination, and 60.8 (4.9) degrees for pronation. The differences between the measurement values by the Gyroscope application and average value were 0.7 degrees for flexion, -0.2 degrees for extension, 0.5 degrees for radial deviation, 0.7 degrees for ulnar deviation, 0.4 degrees for supination, and 0.8 degrees for pronation. The differences in average value were not statistically significant. The authors introduced a new method of measuring the range of wrist motion using the iPhone 4 Gyroscope application that is simpler to use and can be performed by the patient outside a clinical setting.
Watanabe, S M; Goodman, M F
1982-01-01
Enzyme kinetic measurements are presented showing that Km rather than maximum velocity (Vmax) discrimination governs the frequency of forming 2-aminopurine X cytosine base mispairs by DNA polymerase alpha. An in vitro system is used in which incorporation of dTMP or dCMP occurs opposite a template 2-aminopurine, and values for Km and Vmax are obtained. Results from a previous study in which dTTP and dCTP were competing simultaneously for insertion opposite 2-aminopurine indicated that dTMP is inserted 22 times more frequently than dCMP. We now report that the ratio of Km values KCm/KTm = 25 +/- 6, which agrees quantitatively with the dTMP/dCMP incorporation ratio obtained previously. We also report that VCmax is indistinguishable from VTmax. These Km and Vmax data are consistent with predictions from a model, the Km discrimination model, in which replication fidelity is determined by free energy differences between matched and mismatched base pairs. Central to this model is the prediction that the ratio of Km values for insertion of correct and incorrect nucleotides specifies the insertion fidelity, and the maximum velocities of insertion are the same for both nucleotides. PMID:6959128
NASA Technical Reports Server (NTRS)
Driver, R. D.; Lombardi, G.
1977-01-01
Results are reported for measurements of the widths and shifts of the overlapping helium-broadened profiles of the Fe I absorption lines at 3719.94 and 3722.56 A, which were performed in a ballistic piston compressor using a saturated solution of FeCl3 in ethanol. It is found that at 4000 K, the 3719.94-A line has a gamma/n (FWHM) value of approximately 5.2 billionths rad/sec per cu cm, the blue shift of this line corresponds to a beta/n value of about 0.49 billionth rad/sec per cu cm, and the 3722.56-A line has the same values. These results are compared with previous experimental determinations and with theoretical calculations of neutral-line broadening for the Fe I lines. The significance of these measurements with respect to the solar spectrum and cool DG white dwarfs is discussed.
Coulomb Excitation of n-rich nuclei along the N = 50 shell closure
NASA Astrophysics Data System (ADS)
Padilla-Rodal, E.; Galindo-Uribarri, A.; Batchelder, J. C.; Beene, J. R.; Bingham, C.; Brown, B. A.; Lagergren, K. B.; Mueller, P. E.; Radford, D. C.; Stracener, D. W.; Urrego-Blanco, J. P.; Varner, R. L.; Yu, C.-H.
2008-04-01
Recently, we have been investigating characteristics of nuclear states around the neutron-rich mass A=80 region [1]. Using the Radioactive Ion Beams (RIBs) produced at HRIBF, we have successfully measured the B(E2) values for ^78,80,82Ge , using Coulomb excitation in inverse kinematics. For the germanium isotopes, these data allow a study of the systematic trend between the subshell N= 40 and the N=50 shell. Using the same technique, we have measured the B(E2) value of various nuclei along the N=50 shell including the radioactive nucleus ^84Se. This value together with our previously measured ^82Ge, and the recent result on ^80Zn from ISOLDE [2] are providing basic experimental information needed for a better understanding of the neutron-rich nuclei around A˜80. We report the new results and compare with shell model calculations. [1] E. Padilla-Rodal et al., Phys. Rev. Lett. 94 (2005) 122501. [2] J. Van de Walle et al., Phys. Rev. Lett. 99 (2007) 142501.
Metacarpophalangeal joint orientation in anthropoid manual phalanges.
Rein, Thomas R; McCarty, Laura A
2012-12-01
The proximal articular surface angle of orientation (AO) of proximal phalanges of the hand and foot has been used to infer the locomotor profile of extinct Miocene catarrhines and early hominins. Previous work has found that joint orientation distinguishes quadrupedal from suspensory anthropoids. The purpose of this study is to expand on previous research by examining this feature within and across several primate clades, allowing us to investigate the potential influences of locomotion, substrate usage, hand posture, and phylogeny. We also report AO measurements in human proximal hand phalanges, allowing us to examine human skeletal variation within a wide comparative context. The angle of orientation was measured on manual proximal third phalanges of 21 extant anthropoid species using a Microscribe digitizer. Comparisons were made between locomotor groups within hominoids, platyrrhines, and cercopithecoids. Proximal phalanges of quadrupedal species were characterized by greater dorsal orientation than those of suspensory taxa in hominoids and atelids. In addition, arboreal quadrupeds had greater AO values than terrestrial quadrupeds within the Cercopithecoidea. However, within the terrestrial locomotor group, mean AO values did not differ between palmigrade and digitigrade taxa. Thus, while there appears to be a functional signal related to substrate usage, differences in use of hand postures when moving on the ground were not reflected in proximal joint orientation of the proximal phalanx. Finally, we measured relatively low AO values in human phalanges, which might be related to integration with serially homologous pedal phalanges that are under strong selective pressure related to bipedalism. Copyright © 2012 Wiley Periodicals, Inc.
Prediction of quantitative intrathoracic fluid volume to diagnose pulmonary oedema using LabVIEW.
Urooj, Shabana; Khan, M; Ansari, A Q; Lay-Ekuakille, Aimé; Salhan, Ashok K
2012-01-01
Pulmonary oedema is a life-threatening disease that requires special attention in the area of research and clinical diagnosis. Computer-based techniques are rarely used to quantify the intrathoracic fluid volume (IFV) for diagnostic purposes. This paper discusses a software program developed to detect and diagnose pulmonary oedema using LabVIEW. The software runs on anthropometric dimensions and physiological parameters, mainly transthoracic electrical impedance (TEI). This technique is accurate and faster than existing manual techniques. The LabVIEW software was used to compute the parameters required to quantify IFV. An equation relating per cent control and IFV was obtained. The results of predicted TEI and measured TEI were compared with previously reported data to validate the developed program. It was found that the predicted values of TEI obtained from the computer-based technique were much closer to the measured values of TEI. Six new subjects were enrolled to measure and predict transthoracic impedance and hence to quantify IFV. A similar difference was also observed in the measured and predicted values of TEI for the new subjects.
[Reproducibility of subjective refraction measurement].
Grein, H-J; Schmidt, O; Ritsche, A
2014-11-01
Reproducibility of subjective refraction measurement is limited by various factors. The main factors affecting reproducibility include the characteristics of the measurement method and of the subject and the examiner. This article presents the results of a study on this topic, focusing on the reproducibility of subjective refraction measurement in healthy eyes. The results of previous studies are not all presented in the same way by the respective authors and cannot be fully standardized without consulting the original scientific data. To the extent that they are comparable, the results of our study largely correspond largely with those of previous investigations: During repeated subjective refraction measurement, 95% of the deviation from the mean value was approximately ±0.2 D to ±0.65 D for the spherical equivalent and cylindrical power. The reproducibility of subjective refraction measurement in healthy eyes is limited, even under ideal conditions. Correct assessment of refraction results is only feasible after identifying individual variability. Several measurements are required. Refraction cannot be measured without a tolerance range. The English full-text version of this article is available at SpringerLink (under supplemental).
NIST Calibration of a Neutron Spectrometer ROSPEC.
Heimbach, Craig
2006-01-01
A neutron spectrometer was acquired for use in the measurement of National Institute of Standards and Technology neutron fields. The spectrometer included options for the measurement of low and high energy neutrons, for a total measurement range from 0.01 eV up to 17 MeV. The spectrometer was evaluated in calibration fields and was used to determine the neutron spectrum of an Americium-Beryllium neutron source. The calibration fields used included bare and moderated (252)Cf, monoenergetic neutron fields of 2.5 MeV and 14 MeV, and a thermal-neutron beam. Using the calibration values determined in this exercise, the spectrometer gives a good approximation of the neutron spectrum, and excellent values for neutron fluence, for all NIST calibration fields. The spectrometer also measured an Americium-Beryllium neutron field in a NIST exposure facility and determined the field quite well. The spectrometer measured scattering effects in neutron spectra which previously could be determined only by calculation or integral measurements.
Striatal action-value neurons reconsidered.
Elber-Dorozko, Lotem; Loewenstein, Yonatan
2018-05-31
It is generally believed that during economic decisions, striatal neurons represent the values associated with different actions. This hypothesis is based on studies, in which the activity of striatal neurons was measured while the subject was learning to prefer the more rewarding action. Here we show that these publications are subject to at least one of two critical confounds. First, we show that even weak temporal correlations in the neuronal data may result in an erroneous identification of action-value representations. Second, we show that experiments and analyses designed to dissociate action-value representation from the representation of other decision variables cannot do so. We suggest solutions to identifying action-value representation that are not subject to these confounds. Applying one solution to previously identified action-value neurons in the basal ganglia we fail to detect action-value representations. We conclude that the claim that striatal neurons encode action-values must await new experiments and analyses. © 2018, Elber-Dorozko et al.
Towards metering tap water by Lorentz force velocimetry
NASA Astrophysics Data System (ADS)
Vasilyan, Suren; Ebert, Reschad; Weidner, Markus; Rivero, Michel; Halbedel, Bernd; Resagk, Christian; Fröhlich, Thomas
2015-11-01
In this paper, we present enhanced flow rate measurement by applying the contactless Lorentz Force Velocimetry (LFV) technique. Particularly, we show that the LFV is a feasible technique for metering the flow rate of salt water in a rectangular channel. The measurements of the Lorentz forces as a function of the flow rate are presented for different electrical conductivities of the salt water. The smallest value of conductivity is achieved at 0.06 S·m-1, which corresponds to the typical value of tap water. In comparison with previous results, the performance of LFV is improved by approximately 2 orders of magnitude by means of a high-precision differential force measurement setup. Furthermore, the sensitivity curve and the calibration factor of the flowmeter are provided based on extensive measurements for the flow velocities ranging from 0.2 to 2.5 m·s-1 and conductivities ranging from 0.06 to 10 S·m-1.
Transforming hemoglobin measurement in trauma patients: noninvasive spot check hemoglobin.
Joseph, Bellal; Pandit, Viraj; Aziz, Hassan; Kulvatunyou, Narong; Zangbar, Bardiya; Tang, Andrew; O' Keeffe, Terence; Jehangir, Qasim; Snyder, Kara; Rhee, Peter
2015-01-01
Technological advances now allow for noninvasive Hbg measurements. Previous studies have reported on the efficacy of continuous noninvasive Hgb devices. Recently, a new device, Pronto-7, a spot check pulse CO-oximeter has become available. The aim of our study was to assess noninvasive Hgb measurement in trauma patients. We performed a prospective cohort analysis of all trauma patients presenting to our Level I trauma center. Invasive Hgb and spot check Hgb measurements were obtained simultaneously at presentation. Spot check was measured 2 times with each invasive Hgb value. Normal Hgb was defined as >8 mg/dL. Spearman correlation and Bland-Altman analysis was performed. A total of 525 patients had attempted spot check Hgb measurements with a success rate of 86% (n = 450). A total of 450 invasive and 1,350 spot check Hgb measurements were obtained. Mean ± SD age was 41 ± 21 years, 74% were male, and mean Injury Severity Score was 21 ± 13. Thirty-eight percent (n = 173) of patients had Hgb ≤8 mg/dL at presentation. Mean invasive Hgb was 11.5 ± 4.36 g/dL, mean spot check Hgb 11.1 ± 3.60 g/dL, and mean difference was 0.3 ± 1.3 g/dL. Spot check Hgb values had strong correlation with invasive Hgb measurements (R(2) = 0.77; R = 0.86; p = 0.04) with 76% accuracy and 95.4% sensitivity. Spot check Hgb monitoring had excellent correlation with invasive Hgb measurements. Application of spot check has more clinical use as compared with previous continuous Hgb monitoring. This novel technology allows immediate and accurate Hgb measurements in trauma patients. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kang, Yun; Wu, Shunxiang; Cao, Da; Weng, Wei
2018-03-01
In this paper, we present new definitions on distance and similarity measures between intuitionistic fuzzy sets (IFSs) by combining with hesitation degree. First, we discuss the limitations in traditional distance and similarity measures, which are caused by the neglect of hesitation degree's influence. Even though a vector-valued similarity measure was proposed, which has two components indicating similarity and hesitation aspects, it still cannot perform well in practical applications because hesitation works only when the values of similarity measures are equal. In order to overcome the limitations, we propose new definitions on hesitation, distance and similarity measures, and research some theorems which satisfy the requirements of the proposed definitions. Meanwhile, we investigate the relationships among hesitation, distance, similarity and entropy of IFSs to verify the consistency of our work and previous research. Finally, we analyse and discuss the advantages and disadvantages of the proposed similarity measure in detail, and then we apply the proposed measures (dH and SH) to deal with pattern recognition problems, and demonstrate that they outperform state-of-the-art distance and similarity measures.
K2 ROTATION PERIODS FOR LOW-MASS HYADS AND THE IMPLICATIONS FOR GYROCHRONOLOGY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Douglas, S. T.; Agüeros, M. A.; Covey, K. R.
2016-05-01
As the closest open cluster to the Sun, the Hyades is an important benchmark for many stellar properties, but its members are also scattered widely over the sky. Previous studies of stellar rotation in the Hyades relied on targeted observations of single stars or data from shallower all-sky variability surveys. The re-purposed Kepler mission, K2 , is the first opportunity to measure rotation periods ( P {sub rot}) for many Hyads simultaneously while also being sensitive to fully convective M dwarf members. We analyze K2 data for 65 Hyads and present P {sub rot} values for 48. Thirty-seven of thesemore » are new measurements, including the first P {sub rot} measurements for fully convective Hyads. For 9 of the 11 stars with P {sub rot} in the literature and this work, the measurements are consistent; we attribute the two discrepant cases to spot evolution. Nearly all stars with masses ≲0.3 M {sub ⊙} are rapidly rotating, indicating a change in rotation properties at the boundary to full convection. When confirmed and candidate binaries are removed from the mass–period plane, only three rapid rotators with masses ≳0.3 M {sub ⊙} remain. This is in contrast to previous results showing that the single-valued mass–period sequence for ≈600 Myr old stars ends at ≈0.65 M {sub ⊙} when binaries are included. We also find that models of rotational evolution predict faster rotation than is actually observed at ≈600 Myr for stars ≲0.9 M {sub ⊙}. The dearth of single rapid rotators more massive than ≈0.3 M {sub ⊙} indicates that magnetic braking is more efficient than previously thought, and that age–rotation studies must account for multiplicity.« less
ERIC Educational Resources Information Center
Palocsay, Susan W.; Wood, William C.
2014-01-01
"Bloomberg Businessweek" ranks U.S. undergraduate business programs annually. These rankings provide a convenient overall measure of quality, which is important in today's environment of concern about higher education costs and employment after graduation. Data envelopment analysis (DEA) has advantages over previous regression…
Estimating Critical Values for Strength of Alignment among Curriculum, Assessments, and Instruction
ERIC Educational Resources Information Center
Fulmer, Gavin W.
2011-01-01
School accountability decisions based on standardized tests hinge on the degree of alignment of the test with the state's standards documents. Yet, there exist no established criteria for judging strength of alignment. Previous measures of alignment among tests, standards, and teachers' instruction have yielded mixed results that are difficult to…
Factors influencing the robustness of P-value measurements in CT texture prognosis studies
NASA Astrophysics Data System (ADS)
McQuaid, Sarah; Scuffham, James; Alobaidli, Sheaka; Prakash, Vineet; Ezhil, Veni; Nisbet, Andrew; South, Christopher; Evans, Philip
2017-07-01
Several studies have recently reported on the value of CT texture analysis in predicting survival, although the topic remains controversial, with further validation needed in order to consolidate the evidence base. The aim of this study was to investigate the effect of varying the input parameters in the Kaplan-Meier analysis, to determine whether the resulting P-value can be considered to be a robust indicator of the parameter’s prognostic potential. A retrospective analysis of the CT-based normalised entropy of 51 patients with lung cancer was performed and overall survival data for these patients were collected. A normalised entropy cut-off was chosen to split the patient cohort into two groups and log-rank testing was performed to assess the survival difference of the two groups. This was repeated for varying normalised entropy cut-offs and varying follow-up periods. Our findings were also compared with previously published results to assess robustness of this parameter in a multi-centre patient cohort. The P-value was found to be highly sensitive to the choice of cut-off value, with small changes in cut-off producing substantial changes in P. The P-value was also sensitive to follow-up period, with particularly noisy results at short follow-up periods. Using matched conditions to previously published results, a P-value of 0.162 was obtained. Survival analysis results can be highly sensitive to the choice in texture cut-off value in dichotomising patients, which should be taken into account when performing such studies to avoid reporting false positive results. Short follow-up periods also produce unstable results and should therefore be avoided to ensure the results produced are reproducible. Previously published findings that indicated the prognostic value of normalised entropy were not replicated here, but further studies with larger patient numbers would be required to determine the cause of the different outcomes.
Berman, Elena S.F.; Levin, Naomi E.; Landais, Amaelle; Li, Shuning; Owano, Thomas
2013-01-01
Stable isotopes of water have long been used to improve understanding of the hydrological cycle, catchment hydrology, and polar climate. Recently, there has been increasing interest in measurement and use of the less-abundant 17O isotope in addition to 2H and 18O. Off-axis integrated cavity output spectroscopy (OA-ICOS) is demonstrated for accurate and precise measurements δ18O, δ17O, and 17O-excess in liquid water. OA-ICOS involves no sample conversion and has a small footprint, allowing measurements to be made by researchers collecting the samples. Repeated (514) high-throughput measurements of the international isotopic reference water standard GISP demonstrate the precision and accuracy of OA-ICOS: δ18OVSMOW-SLAP =−24.74 ± 0.07 ‰ (1σ) and δ17OVSMOW-SLAP = −13.12 ± 0.05 ‰ (1σ). For comparison, the IAEA value for δ18OVSMOW-SLAP is −24.76 ± 0.09 ‰ (1σ) and an average of previously reported values for δ17OVSMOW-SLAP is −13.12 ± 0.06 ‰ (1σ). Multiple (26) high-precision measurements of GISP provide a 17O-excessVSMOW-SLAP of 23 ± 10 per meg (1σ); an average of previously reported values for 17O-excessVSMOW-SLAP is 22 ± 11 per meg (1σ). For all these OA-ICOS measurements, precision can be further enhanced by additional averaging. OA-ICOS measurements were compared with two independent isotope ratio mass spectrometry (IRMS) laboratories and shown to have comparable accuracy and precision as the current fluorination-IRMS techniques in δ18O, δ17O, and 17O-excess. The ability to measure accurately δ18O, δ17O, and 17O-excess in liquid water inexpensively and without sample conversion is expected to increase vastly the application of δ17O and 17O-excess measurements for scientific understanding of the water cycle, atmospheric convection, and climate modeling among others. PMID:24032448
Branch breakage under snow and ice loads.
Cannell, M G; Morgan, J
1989-09-01
Measurements were made on branches and trunks of Picea sitchensis (Bong.) Carr. to determine the relationship between (i) the bending moment at the bases of branches that cause breakage, and (ii) midpoint diameter cubed. The theory for cantilever beams was then used to calculate the basal bending moments and midpoint diameters of branches with different numbers of laterals and endpoint deflections, given previously measured values of Young's modulus, taper and weights of foliage and wood. Snow and ice loads (equal to 2 and 4 g cm(-1) of shoot, respectively) were then included in the calculation to determine whether the basal bending moments exceeded the breakage values. The likelihood of breakage increased with an increase in (i) number of laterals, and (ii) endpoint deflection under self weight (without snow or ice)-features that had previously been shown to lessen the amount of branch wood required to support a unit of foliage. However, branches which deflected moderately (> 10% of their length) under their own weight deflected greatly under snow or ice loads and might shed powdery snow before breakage occurs.
Comparison of North and South American biomes from AVHRR observations
NASA Technical Reports Server (NTRS)
Goward, Samuel N.; Dye, Dennis; Kerber, Arlene; Kalb, Virginia
1987-01-01
Previous analysis of the North American continent with AVHRR-derived vegetation index measurements showed a strong relation between known patterns of vegetation seasonality, productivity and the spectral vegetation index measurements. This study extends that analysis to South America to evaluate the degree to which these findings extend to tropical regions. The results show that the spectral vegetation index measurements provide a general indicator of vegetation activity across the major biomes of the Western Hemisphere of the earth, including tropical regions. The satellite-observed patterns are strongly related to the known climatology of the continents and may offer a means to improve understanding of global bioclimatology. For example, South America is shown to have a longer growing season with much earlier spring green-up than North America. The time integral of the measurements, computed from 12 composited monthly values, produces a value that is related to published net primary productivity data. However, limited net primary production data does not allow complete evaluation of satellite-observed contrasts between North and South American biomes. These results suggest that satellite-derived spectral vegetation index measurements are of great potential value in improving knowledge of the earth's biosphere.
Novel measuring strategies in neutron interferometry
NASA Astrophysics Data System (ADS)
Bonse, Ulrich; Wroblewski, Thomas
1985-04-01
Angular misalignment of a sample in a single crystal neutron interferometer leads to systematic errors of the effective sample thickness and in this way to errors in the determination of the coherent scattering length. The misalignment can be determined and the errors can be corrected by a second measurement at a different angular sample position. Furthermore, a method has been developed which allows supervision of the wavelength during the measurements. These two techniques were tested by determining the scattering length of copper. A value of bc = 7.66(4) fm was obtained which is in excellent agreement with previous measurements.
Erdem, Yunus; Özkan, Gülsüm; Ulusoy, Şükrü; Arıcı, Mustafa; Derici, Ülver; Şengül, Şule; Sindel, Şükrü; Ertürk, Şehsuvar
2018-01-01
Intermittent fasting is a phenomenon which can be observed in most humans. The effect of intermittent fasting on blood pressure variability (BPV) has not previously been investigated. The purpose of this study was to assess the effect of fasting on blood pressure (BP) (with office, home, central, and ambulatory blood pressure monitoring [ABPM]) and on BPV. Sixty individuals were included in the study. Office, home, ABPM, and central BP measurements were performed before and during intermittent fasting. Standard deviation and coefficient variation were used for office and home BPV measurement, while the smoothness index was used to calculate ABPM variability. Patients' BP and BPV values before and during intermittent fasting were then compared. Intermittent fasting resulted in a significant decrease in office BP values and ABPM measurements but caused no significant change in home and central BP measurements. Twenty-four hour urinary sodium excretion decreased. Smoothness values obtained from ABPM measurements were low; in other words, BPV was greater. BPV was higher in patients who woke up to eat before sunrise, but BPV was low in patients with high body mass index. Intermittent fasting produced a significant decrease in BP values in terms of office and ABPM measurements in this study but caused no significant change in central BP and home measurements. We also identified an increase in BPV during intermittent fasting, particularly in patients who rose before sunrise. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Measuring interdependence in ambulatory care.
Katerndahl, David; Wood, Robert; Jaen, Carlos R
2017-04-01
Complex systems differ from complicated systems in that they are nonlinear, unpredictable and lacking clear cause-and-effect relationships, largely due to the interdependence of their components (effects of interconnectedness on system behaviour and consequences). The purpose of this study was to demonstrate the potential for network density to serve as a measure of interdependence, assess its concurrent validity and test whether the use of valued or binary ties yields better results. This secondary analysis used the 2010 National Ambulatory Care Medical Survey to assess interdependence of 'top 20' diagnoses seen and medications prescribed for 14 specialties. The degree of interdependence was measured as the level of association between diagnoses and drug interactions among medications. Both valued and binary network densities were computed for each specialty. To assess concurrent validity, these measures were correlated with previously-derived valid measures of complexity of care using the same database, adjusting for diagnosis and medication diversity. Partial correlations between diagnosis density, and both diagnosis and total input complexity, were significant, as were those between medication density and both medication and total output complexity; for both diagnosis and medication densities, adjusted correlations were higher for binary rather than valued densities. This study demonstrated the feasibility and validity of using network density as a measure of interdependence. When adjusted for measure diversity, density-complexity correlations were significant and higher for binary than valued density. This approach complements other methods of estimating complexity of care and may be applicable to unique settings. © 2015 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Smith, P. L.; Kuehne, M.
1978-01-01
Oscillator strengths for 134 lines from the ground term of neutral titanium have been measured by the hook method. The data, which are normalized to those of Bell, Kalman and Tubbs, agree well with most previously measured data but indicate that there is a line strength dependent error in the National Bureau of Standards compilation of TiIf-values by Wiese and Fuhr.
NASA Astrophysics Data System (ADS)
Phillips, A. A.; Andreoiu, C.; Ball, G. C.; Bandyopadhyay, D.; Behr, J. A.; Chupp, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hayden, M. E.; Hyland, B.; Nuss-Warren, S. R.; Pearson, M. R.; Schumaker, M. A.; Smith, M. B.; Svensson, C. E.; Tardiff, E. R.; Valiente-Dobón, J. J.; Warner, T.
2006-08-01
We have measured the half-life of Xe120 using a high-purity germanium (HPGe) detector to monitor the 176, 178, and 762 keV γ rays from Xe120 β+ decay. The result, 46±0.6 min, differs significantly from the value 40±1 min reported by Andersson [Ark. Fys. 28, 37 (1964)]. We have also measured the half-lives of Cs120 and I120 to be 60±0.7 s and 82.1±0.6 min, respectively, both of which are consistent with previous measurements.
NASA Technical Reports Server (NTRS)
Waddington, C. J.
1978-01-01
Evidence is reexamined which has been cited as suggesting serious errors in the use of fragmentation parameters appropriate to an airlike medium deduced from measurements made in nuclear emulsions to evaluate corrections for certain effects in balloon-borne observations of cosmic-ray nuclei. Fragmentation parameters for hydrogenlike interactions are calculated and shown to be in overall good agreement with those obtained previously for air. Experimentally measured fragmentation parameters in emulsion are compared with values computed semiempirically, and reasonable agreement is indicated.
Rewriting magnetic phase change memory by laser heating
NASA Astrophysics Data System (ADS)
Timmerwilke, John; Liou, Sy-Hwang; Cheng, Shu Fan; Edelstein, Alan S.
2016-04-01
Magnetic phase change memory (MAG PCM) consists of bits with different magnetic permeability values. The bits are read by measuring their effect on a magnetic probe field. Previously low permeability crystalline bits had been written in high permeability amorphous films of Metglas via laser heating. Here data is presented showing that by applying short laser pulses with the appropriate power to previously crystallized regions they can first be vitrified and then again crystallized. Thus, MAG PCM is rewriteable. Technical issues in processing the bits are discussed and results on thermal modeling are presented.
Activation cross sections of α-induced reactions on natZn for Ge and Ga production
NASA Astrophysics Data System (ADS)
Aikawa, M.; Saito, M.; Ebata, S.; Komori, Y.; Haba, H.
2018-07-01
The production cross sections of 68,69Ge and 66,67Ga by α-induced reactions on natZn have been measured using the stacked-foil activation method and off-line γ-ray spectrometry from their threshold energies to 50.7 MeV. The derived cross sections were compared with the previous experimental data and the calculated values in the TENLD-2017 library. Our result shows a slightly larger amplitude than the previous data at the peak, though the peak energy is consistent with them.
Castel, Alan D; Farb, Norman A S; Craik, Fergus I M
2007-06-01
The ability to selectively remember important information is a critical function of memory. Although previous research has suggested that older adults are impaired in a variety of episodic memory tasks, recent work has demonstrated that older adults can selectively remember high-value information. In the present research, we examined how younger and older adults selectively remembered words with various assigned numeric point values, to see whether younger adults could remember more specific value information than could older adults. Both groups were equally good at recalling point values when recalling the range of high-value words, but younger adults outperformed older adults when recalling specific values. Although older adults were more likely to recognize negative value words, both groups exhibited control by not recalling negative value information. The findings suggest that although both groups retain high-value information, older adults rely more on gist-based encoding and retrieval operations, whereas younger adults are able to remember specific numeric value information.
Effects of linking a soil-water-balance model with a groundwater-flow model
Stanton, Jennifer S.; Ryter, Derek W.; Peterson, Steven M.
2013-01-01
A previously published regional groundwater-flow model in north-central Nebraska was sequentially linked with the recently developed soil-water-balance (SWB) model to analyze effects to groundwater-flow model parameters and calibration results. The linked models provided a more detailed spatial and temporal distribution of simulated recharge based on hydrologic processes, improvement of simulated groundwater-level changes and base flows at specific sites in agricultural areas, and a physically based assessment of the relative magnitude of recharge for grassland, nonirrigated cropland, and irrigated cropland areas. Root-mean-squared (RMS) differences between the simulated and estimated or measured target values for the previously published model and linked models were relatively similar and did not improve for all types of calibration targets. However, without any adjustment to the SWB-generated recharge, the RMS difference between simulated and estimated base-flow target values for the groundwater-flow model was slightly smaller than for the previously published model, possibly indicating that the volume of recharge simulated by the SWB code was closer to actual hydrogeologic conditions than the previously published model provided. Groundwater-level and base-flow hydrographs showed that temporal patterns of simulated groundwater levels and base flows were more accurate for the linked models than for the previously published model at several sites, particularly in agricultural areas.
Mondelain, D; Vasilchenko, S; Čermák, P; Kassi, S; Campargue, A
2015-07-21
The room temperature self- and foreign-continua of water vapor have been measured near 4250 cm(-1) with a newly developed high sensitivity cavity ring down spectrometer (CRDS). The typical sensitivity of the recordings is αmin≈ 6 × 10(-10) cm(-1) which is two orders of magnitude better than previous Fourier transform spectroscopy (FTS) measurements in the spectral region. The investigated spectral interval is located in the low energy range of the important 2.1 μm atmospheric transparency window. Self-continuum cross-sections, CS, were retrieved from the quadratic dependence of the spectrum base line level measured for different water vapor pressures between 0 and 15 Torr, after subtraction of the local water monomer lines contribution calculated using HITRAN2012 line parameters. The CS values were determined with 5% accuracy for four spectral points between 4249.2 and 4257.3 cm(-1). Their values of about 3.2 × 10(-23) cm(2) molecule(-1) atm(-1) are found 20% higher than predicted by the MT_CKD V2.5 model but two times weaker than reported in the literature using FTS. The foreign-continuum was evaluated by injecting various amounts of synthetic air in the CRDS cell while keeping the initial water vapor partial pressure constant. The foreign-continuum cross-section, CF, was retrieved from a linear fit of the spectrum base line level versus the air pressure. The obtained CF values are larger by a factor of 4.5 compared to the MT_CKD values and smaller by a factor of 1.7 compared to previous FTS values. As a result, for an atmosphere at room temperature with 60% relative humidity, the foreign-continuum contribution to the water continuum near 4250 cm(-1) is found to be on the same order as the self-continuum contribution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blake, Thomas A.; Brauer, Carolyn S.; Kelly-Gorham, Molly Rose K.
The optical constants n and k can be used to model infrared spectra, including refraction, absorption, reflectance, and emissivity, but obtaining reliable values for solid materials (pure or otherwise) presents a challenge: In the past, the best results for n and k have been obtained from bulk, homogeneous materials, free of defects. That is, materials where the Fresnel equations are operant since there is no light scattering. Since it is often not possible to obtain a pure macroscopic (crystalline) material, it may be possible to press the material into a (uniform, void-free) disk. We have recently been able to domore » this with ammonium sulfate powder and then measured the n & k values via two independent methods: 1) Ellipsometry - which measures the changes in amplitude and phase of light reflected from the material of interest as a function of wavelength and angle of incidence, and 2) Single angle specular reflectance with an FT spectrometer using a specular reflectance device within an FT instrument which measures the change in amplitude of light reflected from the material of interest as a function of wavelength and angle of incidence over a wide wavelength range. The quality of the derived n & k values was tested by generating the reflectance spectra of the pellet and comparing to the calculated to measured reflectance spectra of the pure material which has been previously published. The comparison to literature values showed good accuracy and good agreement, indicating promise to measure other materials by such methods.« less
Collocated tunable wavenumber sensor/actuators for smart structures
NASA Astrophysics Data System (ADS)
Jones, Lori
1994-02-01
Two actuator modules have just come out of burnout. This burnout took longer than anticipated due to power outages during January. The measurements on the smaller actuators have been repeated and agreed with the previously reported values within +/- 10%. Measurements made on a glued stack showed stiffening with increasing stress from a modulus of about 4 Mpsi at 1000 psi to 12 Mpsi at 10,000 psi applied stress -- this shows the advantage of the cofired actuator.
Turbulence and Complex Flow Phenomena in Multi-Stage Axial Turbomachines
2007-05-10
those measured in previous studies of curved wakes (e.g. Weygandt & Metha 1995; Koyama, 1985; Nakayama, 1987 ; Hah & Lakshminarayana, 1982; Ramjee...34curvature terms" u’z/ (U, / R) (Nakayama 1987 ; Weygandt & Metha 1995). Since the shear stress changes sign across the wake, it increase the turbulent...only 20% of the term involving the shear stress, especially -correl /tio n, much less than values measured by, e.g. Nakayama ( 1987 ). The effect of
NASA Astrophysics Data System (ADS)
Irei, Satoshi; Takami, Akinori; Sadanaga, Yasuhiro; Miyoshi, Takao; Arakaki, Takemitsu; Sato, Kei; Kaneyasu, Naoki; Bandow, Hiroshi; Hatakeyama, Shiro
2015-11-01
To obtain evidence for secondary organic aerosol formation during the long-range transport of air masses over the East China Sea, we conducted field measurements in March 2012 at the Fukue atmospheric monitoring station, Nagasaki, in western Japan. The relative abundance of m/z 44 in fine organic aerosol (f44) was measured by an Aerodyne aerosol chemical speciation monitor. The stable carbon isotope ratio (δ13C) of low-volatile water-soluble organic carbon (LV-WSOC) in the daily filter samples of total suspended particulate matter was also analyzed using an elemental-analyzer coupled with an isotope ratio mass spectrometer. Additionally, in situ measurements of NOx and NOy were performed using NOx and NOy analyzers. The measurements showed that, unlike the systematic trends observed in a previous field study, a scatter plot for δ13C of LV-WSOC versus f44 indicated a random variation. Comparison of f44 with the estimated photochemical age by the NOx/NOy ratio revealed that the random distribution of f44 values near 0.2 is likely an indication of saturation already. Such f44 values were significantly lower than the observed f44 (∼0.3) at Hedo in the previous study. These findings imply that the saturation point of f44, and the use of f44 as an oxidation indicator, is case dependent.
Sepehrband, Farshid; Clark, Kristi A.; Ullmann, Jeremy F.P.; Kurniawan, Nyoman D.; Leanage, Gayeshika; Reutens, David C.; Yang, Zhengyi
2015-01-01
We examined whether quantitative density measures of cerebral tissue consistent with histology can be obtained from diffusion magnetic resonance imaging (MRI). By incorporating prior knowledge of myelin and cell membrane densities, absolute tissue density values were estimated from relative intra-cellular and intra-neurite density values obtained from diffusion MRI. The NODDI (neurite orientation distribution and density imaging) technique, which can be applied clinically, was used. Myelin density estimates were compared with the results of electron and light microscopy in ex vivo mouse brain and with published density estimates in a healthy human brain. In ex vivo mouse brain, estimated myelin densities in different sub-regions of the mouse corpus callosum were almost identical to values obtained from electron microscopy (Diffusion MRI: 42±6%, 36±4% and 43±5%; electron microscopy: 41±10%, 36±8% and 44±12% in genu, body and splenium, respectively). In the human brain, good agreement was observed between estimated fiber density measurements and previously reported values based on electron microscopy. Estimated density values were unaffected by crossing fibers. PMID:26096639
Evaluation of Rotor Structural and Aerodynamic Loads using Measured Blade Properties
NASA Technical Reports Server (NTRS)
Jung, Sung N.; You, Young-Hyun; Lau, Benton H.; Johnson, Wayne; Lim, Joon W.
2012-01-01
The structural properties of Higher harmonic Aeroacoustic Rotor Test (HART I) blades have been measured using the original set of blades tested in the wind tunnel in 1994. A comprehensive rotor dynamics analysis is performed to address the effect of the measured blade properties on airloads, blade motions, and structural loads of the rotor. The measurements include bending and torsion stiffness, geometric offsets, and mass and inertia properties of the blade. The measured properties are correlated against the estimated values obtained initially by the manufacturer of the blades. The previously estimated blade properties showed consistently higher stiffnesses, up to 30% for the flap bending in the blade inboard root section. The measured offset between the center of gravity and the elastic axis is larger by about 5% chord length, as compared with the estimated value. The comprehensive rotor dynamics analysis was carried out using the measured blade property set for HART I rotor with and without HHC (Higher Harmonic Control) pitch inputs. A significant improvement on blade motions and structural loads is obtained with the measured blade properties.
Nitric oxide in the upper stratosphere - Measurements and geophysical interpretation
NASA Technical Reports Server (NTRS)
Harvath, J. J.; Frederick, J. E.; Orsini, N.; Douglass, A. R.
1983-01-01
A rocket-borne parachute-deployed chemiluminescence instrument has obtained seven new measurements of atmospheric nitric oxide for altitudes between 30 and 50 km at mid-latitudes. These results, when combined with profiles measured by an earlier version of the instrument, cover all four seasons and provide a more comprehensive picture of upper stratospheric nitric oxide than has been available previously. At the highest altitudes studied, the vertical gradient in mixing ratio displays positive and negative values during different observations, with the largest values tending to appear at the greatest heights in summer. Examination of the differences among the profiles, which exceed a factor of 3 near the stratopause, suggests that they arise from the action of transport processes which carry air into the mid-latitude upper stratosphere from regions of the atmosphere that contain widely different odd-nitrogen abundances.
Simultaneous qubit-loss-free fusion of three multiple W states
NASA Astrophysics Data System (ADS)
Wang, Meiyu; Hao, Quanzhi; Yan, Fengli; Gao, Ting
2018-05-01
Qubit-loss-free fusion for two W states introduced by Li K et al (2016 Phys. Rev. A 94 062315) clearly increases the final size of the obtained W state and greatly reduces the number of fusion steps to achieve a W state of a target size. Motivated by this idea, we propose a qubit-loss-free fusion scheme for fusing three polarization entangled W states simultaneously. The elements of a two-outcome positive-operator valued measurement and the appropriate joint unitary operation for realizing a positive-operator valued measurement measurement are given. As an example, with the assistance of weak cross-Kerr nonlinearities, an optical setup for fusing three W states is proposed. We analyze the success probability of the scheme and the resource cost of the present scheme, as compared to previous work.
Actinide abundances in ordinary chondrites
Hagee, B.; Bernatowicz, T.J.; Podosek, F.A.; Johnson, M.L.; Burnett, D.S.; Tatsumoto, M.
1990-01-01
Measurements of 244Pu fission Xe, U, Th, and light REE (LREE) abundances, along with modal petrographic determinations of phosphate abundances, were carried out on equilibrated ordinary chondrites in order to define better the solar system Pu abundance and to determine the degree of variation of actinide and LREE abundances. Our data permit comparison of the directly measured Pu/ U ratio with that determined indirectly as (Pu/Nd) ?? (Nd/U) assuming that Pu behaves chemically as a LREE. Except for Guaren??a, and perhaps H chondrites in general, Pu concentrations are similar to that determined previously for St. Se??verin, although less precise because of higher trapped Xe contents. Trapped 130Xe 136Xe ratios appear to vary from meteorite to meteorite, but, relative to AVCC, all are similar in the sense of having less of the interstellar heavy Xe found in carbonaceous chondrite acid residues. The Pu/U and Pu/Nd ratios are consistent with previous data for St. Se??verin, but both tend to be slightly higher than those inferred from previous data on Angra dos Reis. Although significant variations exist, the distribution of our Th/U ratios, along with other precise isotope dilution data for ordinary chondrites, is rather symmetric about the CI chondrite value; however, actinide/(LREE) ratios are systematically lower than the CI value. Variations in actinide or LREE absolute and relative abundances are interpreted as reflecting differences in the proportions and/or compositions of more primitive components (chondrules and CAI materials?) incorporated into different regions of the ordinary chondrite parent bodies. The observed variations of Th/U, Nd/U, or Ce/U suggest that measurements of Pu/U on any single equilibrated ordinary chondrite specimen, such as St. Se??verin, should statistically be within ??20-30% of the average solar system value, although it is also clear that anomalous samples exist. ?? 1990.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, M. P.; Lawler, J. E.; Sneden, C.
2013-10-01
Atomic transition probability measurements for 364 lines of Ti II in the UV through near-IR are reported. Branching fractions from data recorded using a Fourier transform spectrometer (FTS) and a new echelle spectrometer are combined with published radiative lifetimes to determine these transition probabilities. The new results are in generally good agreement with previously reported FTS measurements. Use of the new echelle spectrometer, independent radiometric calibration methods, and independent data analysis routines enables a reduction of systematic errors and overall improvement in transition probability accuracy over previous measurements. The new Ti II data are applied to high-resolution visible and UVmore » spectra of the Sun and metal-poor star HD 84937 to derive new, more accurate Ti abundances. Lines covering a range of wavelength and excitation potential are used to search for non-LTE effects. The Ti abundances derived using Ti II for these two stars match those derived using Ti I and support the relative Ti/Fe abundance ratio versus metallicity seen in previous studies.« less
Tavares, Adriana Alexandre S; Lewsey, James; Dewar, Deborah; Pimlott, Sally L
2012-01-01
Previously, development of novel brain radiotracers has largely relied on simple screening tools. Improved selection methods at the early stages of radiotracer discovery and an increased understanding of the relationships between in vitro physicochemical and in vivo radiotracer properties are needed. We investigated if high performance liquid chromatography (HPLC) methodologies could provide criteria for lead candidate selection by comparing HPLC measurements with radiotracer properties in humans. Ten molecules, previously used as radiotracers in humans, were analysed to obtain the following measures: partition coefficient (Log P); permeability (P(m)); percentage of plasma protein binding (%PPB); and membrane partition coefficient (K(m)). Relationships between brain entry measurements (Log P, P(m) and %PPB) and in vivo brain percentage injected dose (%ID); and K(m) and specific binding in vivo (BP(ND)) were investigated. Log P values obtained using in silico packages and flask methods were compared with Log P values obtained using HPLC. The modelled associations with %ID were stronger for %PPB (r(2)=0.65) and P(m) (r(2)=0.77) than for Log P (r(2)=0.47) while 86% of BP(ND) variance was explained by K(m). Log P values were variable dependant on the methodology used. Log P should not be relied upon as a predictor of blood-brain barrier penetration during brain radiotracer discovery. HPLC measurements of permeability, %PPB and membrane interactions may be potentially useful in predicting in vivo performance and hence allow evaluation and ranking of compound libraries for the selection of lead radiotracer candidates at early stages of radiotracer discovery. Copyright © 2012 Elsevier Inc. All rights reserved.
Lifetimes of low-lying excited states in 50 36 86Kr
NASA Astrophysics Data System (ADS)
Henderson, J.; Chester, A.; Ball, G. C.; Caballero-Folch, R.; Domingo, T.; Drake, T. E.; Evitts, L. J.; Garnsworthy, A. B.; Hackman, G.; Hallam, S.; Moukaddam, M.; Ruotsalainen, P.; Smallcombe, J.; Smith, J. K.; Starosta, K.; Svensson, C. E.; Williams, J.
2018-04-01
Background: The evolution of nuclear magic numbers at extremes of isospin is a topic at the forefront of contemporary nuclear physics. N =50 is a prime example, with increasing experimental data coming to light on potentially doubly magic 100Sn and 78Ni at the proton-rich and proton-deficient extremes, respectively; however, experimental discrepancies exist in the data for less exotic systems. Purpose: In 86Kr the B (E 2 ;21+→01+) value—a key indicator of shell evolution—has been experimentally determined by two different methodologies, with the results deviating by 3 σ . Here, we report on a new high-precision measurement of this value, as well as the first measured lifetimes and hence transition strengths for the 22+ and 3(2) - states in the nucleus. Methods: The Doppler-shift attenuation method was implemented using the TRIUMF-ISAC γ -ray escape-suppressed spectrometer (TIGRESS) γ -ray spectrometer and the TIGRESS integrated plunger device. High-statistics Monte Carlo simulations were utilized to extract lifetimes in accordance with state-of-the-art methodologies. Results: Lifetimes of τ (21+)=336 ±4 (stat.)±20 (sys.) fs, τ (22+)=263 ±9 (stat.)±19 (sys.) fs, and τ (3(2) -)=73 ±6 (stat.)±32 (sys.) fs were extracted. This yields a transition strength for the first-excited state of B (E 2 ;21+→01+)=259 ±3 (stat.)±16 (sys.) e2 fm4. Conclusions: The measured lifetime disagrees with the previous Doppler-shift attenuation method measurement by more than 3 σ , while agreeing well with a previous value extracted from Coulomb excitation. The newly extracted B (E 2 ;21+→01+) value indicates a more significant reduction in the N =50 isotones approaching Z =40 .
Homogenization of the lipid profile values.
Pedro-Botet, Juan; Rodríguez-Padial, Luis; Brotons, Carlos; Esteban-Salán, Margarita; García-Lerín, Aurora; Pintó, Xavier; Lekuona, Iñaki; Ordóñez-Llanos, Jordi
Analytical reports from the clinical laboratory are essential to guide clinicians about what lipid profile values should be considered altered and, therefore, require intervention. Unfortunately, there is a great heterogeneity in the lipid values reported as "normal, desirable, recommended or referenced" by clinical laboratories. This can difficult clinical decisions and be a barrier to achieve the therapeutic goals for cardiovascular prevention. A recent international recommendation has added a new heterogeneity factor for the interpretation of lipid profile, such as the possibility of measuring it without previous fasting. All this justifies the need to develop a document that adapts the existing knowledge to the clinical practice of our health system. In this regard, professionals from different scientific societies involved in the measurement and use of lipid profile data have developed this document to establish recommendations that facilitate their homogenization. Copyright © 2017. Publicado por Elsevier España, S.L.U.
New determination of the gravitational constant G with time-of-swing method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tu Liangcheng; Li Qing; Wang Qinglan
A new determination of the Newtonian gravitational constant G is presented by using a torsion pendulum with the time-of-swing method. Compared with our previous measurement with the same method, several improvements greatly reduced the uncertainties as follows: (i) two stainless steel spheres with more homogeneous density are used as the source masses instead of the cylinders used in the previous experiment, and the offset of the mass center from the geometric center is measured and found to be much smaller than that of the cylinders; (ii) a rectangular glass block is used as the main body of the pendulum, whichmore » has fewer vibration modes and hence improves the stability of the period and reduces the uncertainty of the moment of inertia; (iii) both the pendulum and source masses are placed in the same vacuum chamber to reduce the error of measuring the relative positions; (iv) changing the configurations between the ''near'' and ''far'' positions is remotely operated by using a stepper motor to lower the environmental disturbances; and (v) the anelastic effect of the torsion fiber is first measured directly by using two disk pendulums with the help of a high-Q quartz fiber. We have performed two independent G measurements, and the two G values differ by only 9 ppm. The combined value of G is (6.673 49{+-}0.000 18)x10{sup -11} m{sup 3} kg{sup -1} s{sup -2} with a relative uncertainty of 26 ppm.« less
Sphericity determination using resonant ultrasound spectroscopy
Dixon, Raymond D.; Migliori, Albert; Visscher, William M.
1994-01-01
A method is provided for grading production quantities of spherical objects, such as roller balls for bearings. A resonant ultrasound spectrum (RUS) is generated for each spherical object and a set of degenerate sphere-resonance frequencies is identified. From the degenerate sphere-resonance frequencies and known relationships between degenerate sphere-resonance frequencies and Poisson's ratio, a Poisson's ratio can be determined, along with a "best" spherical diameter, to form spherical parameters for the sphere. From the RUS, fine-structure resonant frequency spectra are identified for each degenerate sphere-resonance frequency previously selected. From each fine-structure spectrum and associated sphere parameter values an asphericity value is determined. The asphericity value can then be compared with predetermined values to provide a measure for accepting or rejecting the sphere.
Sphericity determination using resonant ultrasound spectroscopy
Dixon, R.D.; Migliori, A.; Visscher, W.M.
1994-10-18
A method is provided for grading production quantities of spherical objects, such as roller balls for bearings. A resonant ultrasound spectrum (RUS) is generated for each spherical object and a set of degenerate sphere-resonance frequencies is identified. From the degenerate sphere-resonance frequencies and known relationships between degenerate sphere-resonance frequencies and Poisson's ratio, a Poisson's ratio can be determined, along with a 'best' spherical diameter, to form spherical parameters for the sphere. From the RUS, fine-structure resonant frequency spectra are identified for each degenerate sphere-resonance frequency previously selected. From each fine-structure spectrum and associated sphere parameter values an asphericity value is determined. The asphericity value can then be compared with predetermined values to provide a measure for accepting or rejecting the sphere. 14 figs.
A sol-gel monolithic metal-organic framework with enhanced methane uptake.
Tian, Tian; Zeng, Zhixin; Vulpe, Diana; Casco, Mirian E; Divitini, Giorgio; Midgley, Paul A; Silvestre-Albero, Joaquin; Tan, Jin-Chong; Moghadam, Peyman Z; Fairen-Jimenez, David
2018-02-01
A critical bottleneck for the use of natural gas as a transportation fuel has been the development of materials capable of storing it in a sufficiently compact form at ambient temperature. Here we report the synthesis of a porous monolithic metal-organic framework (MOF), which after successful packing and densification reaches 259 cm 3 (STP) cm -3 capacity. This is the highest value reported to date for conformed shape porous solids, and represents a greater than 50% improvement over any previously reported experimental value. Nanoindentation tests on the monolithic MOF showed robust mechanical properties, with hardness at least 130% greater than that previously measured in its conventional MOF counterparts. Our findings represent a substantial step in the application of mechanically robust conformed and densified MOFs for high volumetric energy storage and other industrial applications.
A sol-gel monolithic metal-organic framework with enhanced methane uptake
NASA Astrophysics Data System (ADS)
Tian, Tian; Zeng, Zhixin; Vulpe, Diana; Casco, Mirian E.; Divitini, Giorgio; Midgley, Paul A.; Silvestre-Albero, Joaquin; Tan, Jin-Chong; Moghadam, Peyman Z.; Fairen-Jimenez, David
2018-02-01
A critical bottleneck for the use of natural gas as a transportation fuel has been the development of materials capable of storing it in a sufficiently compact form at ambient temperature. Here we report the synthesis of a porous monolithic metal-organic framework (MOF), which after successful packing and densification reaches 259 cm3 (STP) cm-3 capacity. This is the highest value reported to date for conformed shape porous solids, and represents a greater than 50% improvement over any previously reported experimental value. Nanoindentation tests on the monolithic MOF showed robust mechanical properties, with hardness at least 130% greater than that previously measured in its conventional MOF counterparts. Our findings represent a substantial step in the application of mechanically robust conformed and densified MOFs for high volumetric energy storage and other industrial applications.
High-precision branching-ratio measurement for the superallowed β+ emitter 74Rb
NASA Astrophysics Data System (ADS)
Dunlop, R.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Andreoiu, C.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Glister, J.; Hackman, G.; Hadinia, B.; Leach, K. G.; Rand, E. T.; Starosta, K.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.
2013-10-01
A high-precision branching-ratio measurement for the superallowed β+ decay of 74Rb was performed at the TRIUMF Isotope Separator and Accelerator (ISAC) radioactive ion-beam facility. The scintillating electron-positron tagging array (SCEPTAR), composed of 10 thin plastic scintillators, was used to detect the emitted β particles; the 8π spectrometer, an array of 20 Compton-suppressed HPGe detectors, was used for detecting γ rays that were emitted following Gamow-Teller and nonanalog Fermi β+ decays of 74Rb; and the Pentagonal Array of Conversion Electron Spectrometers (PACES), an array of 5 Si(Li) detectors, was employed for measuring β-delayed conversion electrons. Twenty-three excited states were identified in 74Kr following 8.241(4)×108 detected 74Rb β decays. A total of 58 γ-ray and electron transitions were placed in the decay scheme, allowing the superallowed branching ratio to be determined as B0=99.545(31)%. Combined with previous half-life and Q-value measurements, the superallowed branching ratio measured in this work leads to a superallowed ft value of 3082.8(65) s. Comparisons between this superallowed ft value and the world-average-corrected Ft¯ value, as well as the nonanalog Fermi branching ratios determined in this work, provide guidance for theoretical models of the isospin-symmetry-breaking corrections in this mass region.
Reference Values for Weight, Height, Head Circumference, and Body Mass Index in Turkish Children.
Neyzi, Olcay; Bundak, Rüveyde; Gökçay, Gülbin; Günöz, Hülya; Furman, Andrzej; Darendeliler, Feyza; Baş, Firdevs
2015-12-01
This study aimed to integrate the existing updated reference standards for the growth of Turkish infants and children and to compare these values with World Health Organization (WHO) reference data, data from some European countries, and also with previous local data. Weight, height, and head circumference measurements were obtained on 2,391 boys and 2,102 girls who were regular attenders of a well child clinic and on 1,100 boys and 1,020 girls attending schools in relatively well-off districts in İstanbul. Mean number of measurements per child was 8.2±3.6 in the age group 0-5 years and 5.5±3.3 in the age group 6-18 years. All children were from well-to-do families and all were healthy. All measurements with the exception of measurements at birth, which were based on reported values, were done by trained personnel. The LMS method was used in the analyses and in the construction of the percentile charts. There is an increase in weight for age and body mass index values for age starting in prepubertal ages, indicating an increasing trend for obesity. Compared to WHO reference data, weight and height values in Turkish children were slightly higher in infants and in children younger than 5 years, while they showed similarity to those reported for children from Norway and Belgium. Head circumference values, which were slightly higher than the WHO references in the first 5 years, were comparable to the data on Belgian and Norwegian children in the first 9 years of life. At older ages, Turkish children showed higher values for head circumference. The relatively larger head circumference values were interpreted to reflect a genetic characteristic.
Reference values for pulmonary diffusing capacity for adult native Finns.
Kainu, Annette; Toikka, Jyri; Vanninen, Esko; Timonen, Kirsi L
2017-04-01
Measurement standards for pulmonary diffusing capacity were updated in 2005 by the ATS/ERS Task Force. However, in Finland reference values published in 1982 by Viljanen et al. have been used to date. The main aim of this study was to produce updated reference models for single-breath diffusing capacity for carbon monoxide for Finnish adults. Single-breath diffusing capacity for carbon monoxide was measured in 631 healthy non-smoking volunteers (41.5% male). Reference values for diffusing capacity (DLCO), alveolar volume (VA), diffusing capacity per unit of lung volume (DLCO/VA), and lung volumes were calculated using a linear regression model. Previously used Finnish reference values were found to produce too low predicted values, with mean predicted DLCO 111.0 and 104.4%, and DLCO/VA of 103.5 and 102.7% in males and females, respectively. With the European Coalition for Steel and Coal (ECSC) reference values there was a significant sex difference in DLCO/VA with mean predicted 105.4% in males and 92.8% in females (p < .001). New reference values for DLCO, DLCO/VA, VA, vital capacity (VC), inspiratory vital capacity (IVC), and inspiratory capacity (IC) are suggested for clinical use to replace technically outdated reference values for clinical applications.
Field observations of the electrostatic charges of blowing snow in Hokkaido, Japan
NASA Astrophysics Data System (ADS)
Omiya, S.; Sato, A.
2011-12-01
An electrostatic charge of blowing snow may be a contributing factor in the formation of a snow drift and a snow cornice, and changing of the trajectory of own motion. However, detailed electrification characteristics of blowing snow are not known as there are few reports of charge measurements. We carried out field observations of the electrostatic charges of blowing snow in Tobetsu, Hokkaido, Japan in the mid winter of 2011. An anemovane and a thermohygrometer were used for the meteorological observation. Charge-to-mass ratios of blowing snow were obtained by a Faraday-cage, an electrometer and an electric balance. In this observation period, the air temperature during the blowing snow event was -6.5 to -0.5 degree Celsius. The measured charges in this observation were consistent with the previous studies in sign, which is negative, but they were smaller than the previous one. In most cases, the measured values increased with the temperature decrease, which corresponds with previous studies. However, some results contradicted the tendency, and the maximum value was obtained on the day of the highest air temperature of -0.5 degree Celsius. This discrepancy may be explained from the difference of the snow surface condition on observation day. The day when the maximum value was obtained, the snow surface was covered with old snow, and hard. On the other hand, in many other cases, the snow surface was covered with the fresh snow, and soft. Blowing snow particles on the hard surface can travel longer distance than on the soft one. Therefore, it can be surmised that the hard surface makes the blowing snow particles accumulate a lot of negative charges due to a large number of collisions to the surface. This can be supported by the results of the wind tunnel experiments by Omiya and Sato (2011). By this field observation, it was newly suggested that the electrostatic charge of blowing snow are influenced greatly by the difference of the snow surface condition. REFERENCE: Omiya and Sato,(2010):An electrostatic charge measurement of blowing snow particles focusing on collision frequency to the snow surface. AGU Abstract Database, 2010 Fall Meeting.
High frequency acoustic reflections from an air-snow interface
NASA Astrophysics Data System (ADS)
Courville, Z.; Albert, D. G.; Lieb-Lappen, R.; Fegyveresi, J. M.
2016-12-01
High frequency wave propagation methods can be used to determine in situ near surface micro-pore geometry parameters in real Earth materials including snow. To this end, we have been developing a portable ultrasonic transducer rig to make measurements of acoustic reflections from a variety of natural porous media. Fresh natural snow, in particular, is a difficult material to characterize, as any mechanical interaction is likely to damage the fragile pores and grain bonds. Because acoustic waves are sensitive to the porous material properties, they potentially can be used to measure snow properties in a non-destructive manner. Such methods have already been demonstrated on cohesive porous materials including manufactured foams, porous metals, and sintered glass beads. We conducted high frequency, oblique-angle and near vertical reflection measurements on snow samples in a cold room. We then compare the acoustically derived snow physical parameters, including porosity, with values determined from micro-computed tomography (μCT) and with standard (but destructive) laboratory measurements. Preliminary results using a manufactured open cell foam following previous work by Fellah et al., (2003) shows very good agreement between values of porosity determined from the acoustic measurements and the values determined from μCT image analysis and gravimetric determination. Similarly, preliminary results comparing acoustic measurements of natural, dry snow samples prepared in the laboratory show good agreement between acoustically-derived porosity values and porosity values derived through independent means. Fellah, Z.E.A., S. Berger, W. Lauriks, C. Depollier, C. Aristegui, and J.Y. Chapelon, (2003b), Measuring the porosity and tortuosity of porous materials via reflected waves at oblique incidence, J. Acous. Soc. Am., 113, 2424-2433.
Glycaemic index and glycaemic load values of a selection of popular foods consumed in Hong Kong.
Lok, Kris Y; Chan, Ruth; Chan, Dicken; Li, Liz; Leung, Grace; Woo, Jean; Lightowler, Helen J; Henry, C Jeya K
2010-02-01
The objective of the present paper is to provide glycaemic index (GI) and glycaemic load (GL) values for a variety of foods that are commonly consumed in Hong Kong and expand on the international GI table of Chinese foods. Fasted healthy subjects were given 50 g of available carbohydrate servings of a glucose reference, which was tested twice, and test foods of various brands of noodles (n 5), instant cereals (n 3) and breads (n 2), which were tested once, on separate occasions. For each test food, tests were repeated in ten healthy subjects. Capillary blood glucose was measured via finger-prick samples in fasting subjects ( - 5, 0 min) and at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI of each test food was calculated geometrically by expressing the incremental area under the blood glucose response curve (IAUC) of each test food as a percentage of each subject's average IAUC for the reference food. GL was calculated as the product of the test food's GI and the amount of available carbohydrate in a reference serving size. The majority of GI values of foods tested were medium (a GI value of 56-69) to high (a GI value of 70 or more) and compared well with previously published values. More importantly, our dataset provides GI values of ten foods previously untested and presents values for foods commonly consumed in Hong Kong.
NASA Technical Reports Server (NTRS)
Burris, John; McGee, Thomas; Hoegy, Walt; Newman, Paul; Lait, Leslie; Twigg, Laurence; Sumnicht, Grant; Heaps, William; Hostetler, Chris; Neuber, Roland;
2001-01-01
NASA Goddard Space Flight Center's Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) measured extremely cold temperatures during all three deployments (December 1-16, 1999, January 14-29, 2000 and February 27-March 15, 2000) of the Sage III Ozone Loss and Validation Experiment (SOLVE). Temperatures were significantly below values observed in previous years with large regions regularly below 191 K and frequent temperature retrievals yielding values at or below 187 K. Temperatures well below the saturation point of type I polar stratospheric clouds (PSCs) were regularly encountered but their presence was not well correlated with PSCs observed by the NASA Langley Research Center's Aerosol Lidar co-located with AROTEL. Temperature measurements by meteorological sondes launched within areas traversed by the DC-8 showed minimum temperatures consistent in time and vertical extent with those derived from AROTEL data. Calculations to establish whether PSCs could exist at measured AROTEL temperatures and observed mixing ratios of nitric acid and water vapor showed large regions favorable to PSC formation. On several occasions measured AROTEL temperatures up to 10 K below the NAT saturation temperature were insufficient to produce PSCs even though measured values of nitric acid and water were sufficient for their formation.
On the distortions in calculated GW parameters during slanted atmospheric soundings
NASA Astrophysics Data System (ADS)
de la Torre, Alejandro; Alexander, Peter; Schmidt, Torsten; Llamedo, Pablo; Hierro, Rodrigo
2018-03-01
The significant distortions introduced in the measured atmospheric gravity wavelengths by soundings other than those in vertical and horizontal directions, are discussed as a function of the elevation angle of the sounding path and the gravity wave aspect ratio. Under- or overestimation of real vertical wavelengths during the measurement process depends on the value of these two parameters. The consequences of these distortions on the calculation of the energy and the vertical flux of horizontal momentum are analyzed and discussed in the context of two experimental limb satellite setups: GPS-LEO radio occultations and TIMED/SABER ((Atmosphere using Broadband Emission Radiometry/Thermosphere-Ionosphere-Mesosphere-Energetics and Dynamics)) measurements. Possible discrepancies previously found between the momentum flux calculated from satellite temperature profiles, on site and from model simulations, may to a certain degree be attributed to these distortions. A recalculation of previous momentum flux climatologies based on these considerations seems to be a difficult goal.
The influence of apical oxygen on the increase of Tc in Y Ba2Cu3O7-X
NASA Astrophysics Data System (ADS)
Dul'kin, E.
2004-07-01
The direct current (DC) bulk resistance and acoustic emission of Y Ba2Cu3O7-X ceramic samples have simultaneously been measured during heating in a temperature region of 400-700 K. Near 560 K, an anomaly of rgr, accompanied by an acoustic emission, has been observed. After this anomaly rgr reached a lower value than had previously been measured. The observed rgr decrease and acoustic emission signals confirm that Y Ba2Cu3O7-X ceramic samples absorb oxygen during heating in the temperature region of 500-600 K, as shown by previous dilatometric measurements (Dul'kin 2001 J. Superconductivity 14 497). It is shown that absorbed oxygen atoms enter O4 apical oxygen sites and are able to increase the Tc in Y Ba2Cu3O7-X material.
NASA Astrophysics Data System (ADS)
Qattan, I. A.
2017-06-01
I present a prediction of the e± elastic scattering cross-section ratio, Re+e-, as determined using a new parametrization of the two-photon exchange (TPE) corrections to electron-proton elastic scattering cross section σR. The extracted ratio is compared to several previous phenomenological extractions, TPE hadronic calculations, and direct measurements from the comparison of electron and positron scattering. The TPE corrections and the ratio Re+e- show a clear change of sign at low Q2, which is necessary to explain the high-Q2 form factors discrepancy while being consistent with the known Q2→0 limit. While my predictions are in generally good agreement with previous extractions, TPE hadronic calculations, and existing world data including the recent two measurements from the CLAS and VEPP-3 Novosibirsk experiments, they are larger than the new OLYMPUS measurements at larger Q2 values.
The implications of the COBE diffuse microwave radiation results for cosmic strings
NASA Technical Reports Server (NTRS)
Bennett, David P.; Stebbins, Albert; Bouchet, Francois R.
1992-01-01
We compare the anisotropies in the cosmic microwave background radiation measured by the COBE experiment to those predicted by cosmic string theories. We use an analytic model for the Delta T/T power spectrum that is based on our previous numerical simulations of strings, under the assumption that cosmic strings are the sole source of the measured anisotropy. This implies a value for the string mass per unit length of 1.5 +/- 0.5 x 10 exp -6 C-squared/G. This is within the range of values required for cosmic strings to successfully seed the formation of large-scale structures in the universe. These results clearly encourage further studies of Delta T/T and large-scale structure in the cosmic string model.
Tensor polarization of the ϕ meson photoproduced at high t
NASA Astrophysics Data System (ADS)
McCormick, K.; Audit, G.; Laget, J. M.; Adams, G.; Ambrozewicz, P.; Anciant, E.; Anghinolfi, M.; Asavapibhop, B.; Auger, T.; Avakian, H.; Bagdasaryan, H.; Ball, J. P.; Barrow, S.; Battaglieri, M.; Beard, K.; Bektasoglu, M.; Bellis, M.; Benmouna, N.; Berman, B. L.; Bianchi, N.; Biselli, A. S.; Boiarinov, S.; Bonner, B. E.; Bouchigny, S.; Bradford, R.; Brooks, W. K.; Burkert, V. D.; Butuceanu, C.; Calarco, J. R.; Carman, D. S.; Carnahan, B.; Cetina, C.; Chen, S.; Cole, P. L.; Coleman, A.; Connelly, J.; Cords, D.; Corvisiero, P.; Crabb, D.; Crannell, H.; Cummings, J. P.; de Sanctis, E.; Devita, R.; Degtyarenko, P. V.; Denizli, H.; Dennis, L.; Dharmawardane, K. V.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dragovitsch, P.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Eckhause, M.; Egiyan, H.; Egiyan, K. S.; Elouadrhiri, L.; Eugenio, P.; Farhi, L.; Feuerbach, R. J.; Ficenec, J.; Forest, T. A.; Frolov, V.; Funsten, H.; Gaff, S. J.; Gai, M.; Garçon, M.; Gavalian, G.; Gilad, S.; Gilfoyle, G. P.; Giovanetti, K. L.; Girard, P.; Gordon, C. I.; Griffioen, K.; Guidal, M.; Guillo, M.; Guo, L.; Gyurjyan, V.; Hadjidakis, C.; Hakobyan, R. S.; Hancock, D.; Hardie, J.; Heddle, D.; Hersman, F. W.; Hicks, K.; Hicks, R. S.; Holtrop, M.; Hyde-Wright, C. E.; Ito, M. M.; Jenkins, D.; Joo, K.; Juengst, H. G.; Kelley, J. H.; Khandaker, M.; Kim, W.; Klein, A.; Klein, F. J.; Klimenko, A.; Klusman, M.; Kossov, M.; Kramer, L. H.; Kuang, Y.; Kuhn, S. E.; Kuhn, J.; Lachniet, J.; Langheinrich, J.; Lawrence, D.; Li, Ji; Lukashin, K.; Major, W.; Manak, J. J.; Marchand, C.; McAleer, S.; McNabb, J. W.; Mecking, B. A.; Mehrabyan, S.; Melone, J. J.; Mestayer, M. D.; Meyer, C. A.; Minehart, R.; Mirazita, M.; Miskimen, R.; Morand, L.; Morrow, S. A.; Muccifora, V.; Mueller, J.; Mutchler, G. S.; Napolitano, J.; Nasseripour, R.; Nelson, S. O.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Niczyporuk, B. B.; Niyazov, R. A.; Nozar, M.; Osipenko, M.; Park, K.; Pasyuk, E.; Peterson, G.; Philips, S. A.; Pivnyuk, N.; Pocanic, D.; Pogorelko, O.; Polli, E.; Preedom, B. M.; Price, J. W.; Prok, Y.; Protopopescu, D.; Qin, L. M.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ritchie, B. G.; Ronchetti, F.; Rossi, P.; Rowntree, D.; Rubin, P. D.; Sabatié, F.; Sabourov, K.; Salgado, C.; Santoro, J. P.; Sanzone-Arenhovel, M.; Sapunenko, V.; Sargsyan, M.; Schumacher, R. A.; Serov, V. S.; Shafi, A.; Sharabian, Y. G.; Shaw, J.; Skabelin, A. V.; Smith, E. S.; Smith, T.; Smith, L. C.; Sober, D. I.; Spraker, M.; Stepanyan, S.; Stoler, P.; Strauch, S.; Taiuti, M.; Taylor, S.; Tedeschi, D. J.; Thoma, U.; Thompson, R.; Todor, L.; Tur, C.; Ungaro, M.; Vineyard, M. F.; Vlassov, A. V.; Wang, K.; Weinstein, L. B.; Weller, H.; Weygand, D. P.; Whisnant, C. S.; Witkowski, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Yun, J.; Zhao, J.; Zhou, Z.
2004-03-01
As part of a measurement [
Determination of the Gravitational Constant with a Beam Balance
NASA Astrophysics Data System (ADS)
Schlamminger, St.; Holzschuh, E.; Kündig, W.
2002-09-01
The Newtonian gravitational constant G was determined by means of a novel beam-balance experiment with an accuracy comparable to that of the most precise torsion-balance experiments. The gravitational force of two stainless steel tanks filled with 13 521kg mercury on 1.1kg test masses was measured using a commercial mass comparator. A careful analysis of the data and the experimental error yields G=6.674 07(22)×10-11 m3 kg-1 s-2. This value is in excellent agreement with most values previously obtained with different methods.
Proposed rocket experiments to measure the profile and intensity of the solar He1584A resonance line
NASA Technical Reports Server (NTRS)
Judge, D. L.
1978-01-01
The intensity and profile of the helium resonance line at 584 A from the entire disc of the sun was investigated using a rocket-borne helium-filled spectrometer and a curve of growth technique. The line profile was found to be accurately represented by a Gaussian profile with full width at half maximum of 122 plus or minus 10m A while the integrated intensity was measured to be (2.6 plus or minus 1.3) x 10 to the 9th power/photons sec sq cm at solar levels of F sub 10.7 = 90.8 x 10 to the minus 22th power/sq m H sub z and R sub z = 27. The measured linewidth is in good agreement with previous spectrographic measurement but the integrated intensity is larger than most previous photoelectric measurements. However, the derived line center flux of (2.0 plus or minus 1.0) x 10 to the 10th power/photons sec sq cm A is in good agreement with values inferred from airglow measurements.
Pressure probe and isopiestic psychrometer measure similar turgor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nonami, H.; Boyer, J.S.; Steudle, E.
1987-03-01
Turgor measured with a miniature pressure probe was compared to that measured with an isopiestic thermocouple psychrometer in mature regions of soybean (Glycine max (L.) Merr.) stems. The probe measured turgor directly in cells of intact stems whereas the psychrometer measured the water potential and osmotic potential of excised stem segments and turgor was calculated by difference. When care was taken to prevent dehydration when working with the pressure probe, and diffusive resistance and dilution errors with the psychrometer, both methods gave similar values of turgor whether the plants were dehydrating or rehydrating. This finding, together with the previously demonstratedmore » similarity in turgor measured with the isopiestic psychrometer and a pressure chamber, indicates that the pressure probe provides accurate measurements of turgor despite the need to penetrate the cell. On the other hand, it suggest that as long as precautions are taken to obtain accurate values for the water potential and osmotic potential, turgor can be determined by isopiestic psychrometry in tissues not accessible to the pressure probe for physical reasons.« less
NASA Astrophysics Data System (ADS)
Soulis, K. X.; Valiantzas, J. D.
2012-03-01
The Soil Conservation Service Curve Number (SCS-CN) approach is widely used as a simple method for predicting direct runoff volume for a given rainfall event. The CN parameter values corresponding to various soil, land cover, and land management conditions can be selected from tables, but it is preferable to estimate the CN value from measured rainfall-runoff data if available. However, previous researchers indicated that the CN values calculated from measured rainfall-runoff data vary systematically with the rainfall depth. Hence, they suggested the determination of a single asymptotic CN value observed for very high rainfall depths to characterize the watersheds' runoff response. In this paper, the hypothesis that the observed correlation between the calculated CN value and the rainfall depth in a watershed reflects the effect of soils and land cover spatial variability on its hydrologic response is being tested. Based on this hypothesis, the simplified concept of a two-CN heterogeneous system is introduced to model the observed CN-rainfall variation by reducing the CN spatial variability into two classes. The behaviour of the CN-rainfall function produced by the simplified two-CN system is approached theoretically, it is analysed systematically, and it is found to be similar to the variation observed in natural watersheds. Synthetic data tests, natural watersheds examples, and detailed study of two natural experimental watersheds with known spatial heterogeneity characteristics were used to evaluate the method. The results indicate that the determination of CN values from rainfall runoff data using the proposed two-CN system approach provides reasonable accuracy and it over performs the previous methods based on the determination of a single asymptotic CN value. Although the suggested method increases the number of unknown parameters to three (instead of one), a clear physical reasoning for them is presented.
Thomas, Freddy; Jamin, Eric
2009-09-01
An international collaborative study of isotopic methods applied to control the authenticity of vinegar was organized in order to support the recognition of these procedures as official methods. The determination of the 2H/1H ratio of the methyl site of acetic acid by SNIF-NMR (site-specific natural isotopic fractionation-nuclear magnetic resonance) and the determination of the 13C/12C ratio, by IRMS (isotope ratio mass spectrometry) provide complementary information to characterize the botanical origin of acetic acid and to detect adulterations of vinegar using synthetic acetic acid. Both methods use the same initial steps to recover pure acetic acid from vinegar. In the case of wine vinegar, the determination of the 18O/16O ratio of water by IRMS allows to differentiate wine vinegar from vinegars made from dried grapes. The same set of vinegar samples was used to validate these three determinations. The precision parameters of the method for measuring delta13C (carbon isotopic deviation) were found to be similar to the values previously obtained for similar methods applied to wine ethanol or sugars extracted from fruit juices: the average repeatability (r) was 0.45 per thousand, and the average reproducibility (R) was 0.91 per thousand. As expected from previous in-house study of the uncertainties, the precision parameters of the method for measuring the 2H/1H ratio of the methyl site were found to be slightly higher than the values previously obtained for similar methods applied to wine ethanol or fermentation ethanol in fruit juices: the average repeatability was 1.34 ppm, and the average reproducibility was 1.62 ppm. This precision is still significantly smaller than the differences between various acetic acid sources (delta13C and delta18O) and allows a satisfactory discrimination of vinegar types. The precision parameters of the method for measuring delta18O were found to be similar to the values previously obtained for other methods applied to wine and fruit juices: the average repeatability was 0.15 per thousand, and the average reproducibility was 0.59 per thousand. The above values are proposed as repeatability and reproducibility limits in the current state of the art. On the basis of this satisfactory inter-laboratory precision and on the accuracy demonstrated by a spiking experiment, the authors recommend the adoption of the three isotopic determinations included in this study as official methods for controlling the authenticity of vinegar.
NASA Astrophysics Data System (ADS)
Dattani, Nikesh S.; Zack, Lindsay; Sun, Ming; Johnson, Erin R.; Le Roy, Robert; Ziurys, Lucy
2014-06-01
We report eight new ultra-high precision (±5 kHz) measurements of purely rotational N(1←0) transitions in several vibrational states of all stable isotopologues of the ground X(11Σ+) -state of ZnO. Combined with previous high-resolution (±50 kHz) measurements of purely rotational transitions between higher rotational states for the same system, we are able to build analytic potentials for 64Zn16O, 66Zn16O, 67Zn16O, 68Zn16O, and 70Zn16O, that are in full agreement with all known spectroscopic measurements of the system. Despite there being absolutely no vibrational information, our empirical potentials are able to determine the size of the vibrational spacings and the bond lengths, each with a precision of more than two orders of magnitude greater than the most precise empirical values previously known. We then use the XDM method to calculate values for the C6, C8, and C10 long-range constants for this molecule, and use these to accurately anchor the long-range regions of the potentials, where no measurements have yet been performed. In the region lying between the short-range measurements and the long-range theory on which our potentials are based, our final analytic global potentials are in very good agreement with state of the art ab initio potentials. L. N. Zack, R. L. Pulliam, L. M. Ziurys, J. Mol. Spec., 256, 186-191 (2009).
Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity Generator
NASA Astrophysics Data System (ADS)
Martins, L. Lages; Ribeiro, A. Silva; Alves e Sousa, J.; Forbes, Alistair B.
2012-09-01
This article describes the measurement uncertainty evaluation of the dew-point temperature when using a two-pressure humidity generator as a reference standard. The estimation of the dew-point temperature involves the solution of a non-linear equation for which iterative solution techniques, such as the Newton-Raphson method, are required. Previous studies have already been carried out using the GUM method and the Monte Carlo method but have not discussed the impact of the approximate numerical method used to provide the temperature estimation. One of the aims of this article is to take this approximation into account. Following the guidelines presented in the GUM Supplement 1, two alternative approaches can be developed: the forward measurement uncertainty propagation by the Monte Carlo method when using the Newton-Raphson numerical procedure; and the inverse measurement uncertainty propagation by Bayesian inference, based on prior available information regarding the usual dispersion of values obtained by the calibration process. The measurement uncertainties obtained using these two methods can be compared with previous results. Other relevant issues concerning this research are the broad application to measurements that require hygrometric conditions obtained from two-pressure humidity generators and, also, the ability to provide a solution that can be applied to similar iterative models. The research also studied the factors influencing both the use of the Monte Carlo method (such as the seed value and the convergence parameter) and the inverse uncertainty propagation using Bayesian inference (such as the pre-assigned tolerance, prior estimate, and standard deviation) in terms of their accuracy and adequacy.
NASA Technical Reports Server (NTRS)
Welton, Ellsworth J.; Voss, Kenneth J.; Quinn, Patricia K.; Flatau, Piotr J.; Markowicz, Krzysztof; Campbell, James R.; Spinhirne, James D.; Gordon, Howard R.; Johnson, James E.; Starr, David OC. (Technical Monitor)
2001-01-01
Micro-pulse lidar systems (MPL) were used to measure aerosol properties during the Indian Ocean Experiment (INDOEX) 1999 field phase. Measurements were made from two platforms: the NOAA ship RN Ronald H. Brown, and the Kaashidhoo Climate Observatory (KCO) in the Maldives. Sunphotometers were used to provide aerosol optical depths (AOD) needed to calibrate the MPL. This study focuses on the height distribution and optical properties (at 523 nm) of aerosols observed during the campaign. The height of the highest aerosols (top height) was calculated and found to be below 4 km for most of the cruise. The marine boundary layer (MBL) top was calculated and found to be less than 1 km. MPL results were combined with air mass trajectories, radiosonde profiles of temperature and humidity, and aerosol concentration and optical measurements. Humidity varied from approximately 80% near the surface to 50% near the top height during the entire cruise. The average value and standard deviation of aerosol optical parameters were determined for characteristic air mass regimes. Marine aerosols in the absence of any continental influence were found to have an AOD of 0.05 +/- 0.03, an extinction-to-backscatter ratio (S-ratio) of 33 +/- 6 sr, and peak extinction values around 0.05/km (near the MBL top). The marine results are shown to be in agreement with previously measured and expected values. Polluted marine areas over the Indian Ocean, influenced by continental aerosols, had AOD values in excess of 0.2, S-ratios well above 40 sr, and peak extinction values approximately 0.20/km (near the MBL top). The polluted marine results are shown to be similar to previously published values for continental aerosols. Comparisons between MPL derived extinction near the ship (75 m) and extinction calculated at ship-level using scattering measured by a nephelometer and absorption using a PSAP were conducted. The comparisons indicated that the MPL algorithm (using a constant S-ratio throughout the lower troposphere) calculates extinction near the surface in agreement with the ship-level measurements only when the MBL aerosols are well mixed with aerosols above. Finally, a review of the MPL extinction profiles showed that the model of aerosol vertical extinction developed during an earlier INDOEX field campaign (at the Maldives) did not correctly describe the true vertical distribution over the greater Indian Ocean region. Using the average extinction profile and AOD obtained during marine conditions, a new model of aerosol vertical extinction was determined for marine atmospheres over the Indian Ocean. A new model of aerosol vertical extinction for polluted marine atmospheres was also developed using the average extinction profile and AOD obtained during marine conditions influenced by continental aerosols.
NASA Astrophysics Data System (ADS)
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; Chen, Q.; Kessler, S. H.; Massoli, P.; Hildebrandt Ruiz, L.; Fortner, E.; Williams, L. R.; Wilson, K. R.; Surratt, J. D.; Donahue, N. M.; Jayne, J. T.; Worsnop, D. R.
2014-07-01
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), organic mass-to-organic carbon (OM : OC), and carbon oxidation state (OSC) for a vastly expanded laboratory dataset of multifunctional oxidized OA standards. For the expanded standard dataset, the "Aiken-Explicit" method (Aiken et al., 2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios, reproduces known molecular O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12% respectively. The more commonly used "Aiken-Ambient" method, which uses empirically estimated H2O+ and CO+ ion intensities to avoid gas phase air interferences at these ions, reproduces O : C and H : C of multifunctional oxidized species within 28% and 14% of known values. These values are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H2O+, CO+, and CO2+ fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO+ and H2O+ produced from many oxidized species. Combined AMS-vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method reduces the systematic biases and reproduces O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C and H : C values is smaller (12% and 4% respectively) for synthetic mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OSC values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OSC units). This indicates that OSC is a more robust metric of oxidation than O : C, likely since OSC is not affected by hydration or dehydration, either in the atmosphere or during analysis.
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; ...
2015-01-12
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state (OS C) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determinemore » elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H 2O + and CO + ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2O +, CO +, and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and especially H 2O + produced from many oxidized species. Combined AMS–vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
..., the water consumption flow rate of commercial prerinse spray valves. (b) Testing and Calculations. The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed in... the previous step. Round the final water consumption value to one decimal place as follows: (1) A...
ERIC Educational Resources Information Center
Armel, K. Carrie; Pulido, Carmen; Wixted, John T.; Chiba, Andrea A.
2009-01-01
We demonstrate here that initially neutral items can acquire "specific" value based on their associated outcomes, and that responses of physiological systems to such previously meaningless stimuli can rapidly reflect this associative history. Each participant participated in an associative learning task in which four neutral abstract pictures were…
ERIC Educational Resources Information Center
Brinkerhoff, Robert O.; Dressler, Dennis
2002-01-01
Discusses the causes of variability of training impact and problems with previous models for evaluation of training. Presents the Success Case Evaluation approach as a way to measure the impact of training and build learning capability to increase the business value of training by focusing on a small number of trainees. (Author/LRW)
The accuracy of parent-reported height and weight for 6-12 year old U.S. children.
Wright, Davene R; Glanz, Karen; Colburn, Trina; Robson, Shannon M; Saelens, Brian E
2018-02-12
Previous studies have examined correlations between BMI calculated using parent-reported and directly-measured child height and weight. The objective of this study was to validate correction factors for parent-reported child measurements. Concordance between parent-reported and investigator measured child height, weight, and BMI (kg/m 2 ) among participants in the Neighborhood Impact on Kids Study (n = 616) was examined using the Lin coefficient, where a value of ±1.0 indicates perfect concordance and a value of zero denotes non-concordance. A correction model for parent-reported height, weight, and BMI based on commonly collected demographic information was developed using 75% of the sample. This model was used to estimate corrected measures for the remaining 25% of the sample and measured concordance between correct parent-reported and investigator-measured values. Accuracy of corrected values in classifying children as overweight/obese was assessed by sensitivity and specificity. Concordance between parent-reported and measured height, weight and BMI was low (0.007, - 0.039, and - 0.005 respectively). Concordance in the corrected test samples improved to 0.752 for height, 0.616 for weight, and 0.227 for BMI. Sensitivity of corrected parent-reported measures for predicting overweight and obesity among children in the test sample decreased from 42.8 to 25.6% while specificity improved from 79.5 to 88.6%. Correction factors improved concordance for height and weight but did not improve the sensitivity of parent-reported measures for measuring child overweight and obesity. Future research should be conducted using larger and more nationally-representative samples that allow researchers to fully explore demographic variance in correction coefficients.
NASA Astrophysics Data System (ADS)
Fuchs, Hendrik; Tan, Zhaofeng; Lu, Keding; Bohn, Birger; Broch, Sebastian; Brown, Steven S.; Dong, Huabin; Gomm, Sebastian; Häseler, Rolf; He, Lingyan; Hofzumahaus, Andreas; Holland, Frank; Li, Xin; Liu, Ying; Lu, Sihua; Min, Kyung-Eun; Rohrer, Franz; Shao, Min; Wang, Baolin; Wang, Ming; Wu, Yusheng; Zeng, Limin; Zhang, Yinson; Wahner, Andreas; Zhang, Yuanhang
2017-01-01
In 2014, a large, comprehensive field campaign was conducted in the densely populated North China Plain. The measurement site was located in a botanic garden close to the small town Wangdu, without major industry but influenced by regional transportation of air pollution. The loss rate coefficient of atmospheric hydroxyl radicals (OH) was quantified by direct measurements of the OH reactivity. Values ranged between 10 and 20 s-1 for most of the daytime. Highest values were reached in the late night with maximum values of around 40 s-1. OH reactants mainly originated from anthropogenic activities as indicated (1) by a good correlation between measured OH reactivity and carbon monoxide (linear correlation coefficient R2 = 0.33) and (2) by a high contribution of nitrogen oxide species to the OH reactivity (up to 30 % in the morning). Total OH reactivity was measured by a laser flash photolysis-laser-induced fluorescence instrument (LP-LIF). Measured values can be explained well by measured trace gas concentrations including organic compounds, oxygenated organic compounds, CO and nitrogen oxides. Significant, unexplained OH reactivity was only observed during nights, when biomass burning of agricultural waste occurred on surrounding fields. OH reactivity measurements also allow investigating the chemical OH budget. During this campaign, the OH destruction rate calculated from measured OH reactivity and measured OH concentration was balanced by the sum of OH production from ozone and nitrous acid photolysis and OH regeneration from hydroperoxy radicals within the uncertainty of measurements. However, a tendency for higher OH destruction compared to OH production at lower concentrations of nitric oxide is also observed, consistent with previous findings in field campaigns in China.
Improved COD Measurements for Organic Content in Flowback Water with High Chloride Concentrations.
Cardona, Isabel; Park, Ho Il; Lin, Lian-Shin
2016-03-01
An improved method was used to determine chemical oxygen demand (COD) as a measure of organic content in water samples containing high chloride content. A contour plot of COD percent error in the Cl(-)-Cl(-):COD domain showed that COD errors increased with Cl(-):COD. Substantial errors (>10%) could occur in low Cl(-):COD regions (<300) for samples with low (<10 g/L) and high chloride concentrations (>25 g/L). Applying the method to flowback water samples resulted in COD concentrations ranging in 130 to 1060 mg/L, which were substantially lower than the previously reported values for flowback water samples from Marcellus Shale (228 to 21 900 mg/L). It is likely that overestimations of COD in the previous studies occurred as result of chloride interferences. Pretreatment with mercuric sulfate, and use of a low-strength digestion solution, and the contour plot to correct COD measurements are feasible steps to significantly improve the accuracy of COD measurements.
Absolute ozone absorption cross section in the Huggins Chappuis minimum (350-470 nm) at 296 K
NASA Astrophysics Data System (ADS)
Axson, J. L.; Washenfelder, R. A.; Kahan, T. F.; Young, C. J.; Vaida, V.; Brown, S. S.
2011-08-01
We report the ozone absolute absorption cross section between 350-470 nm, the minimum between the Huggins and Chappuis bands, where the ozone cross section is less than 10-22 cm2. Ozone spectra were acquired using an incoherent broadband cavity enhanced absorption spectrometer, with three channels centered at 365, 405, and 455 nm. The accuracy of the measured cross section is 2 %. Previous measurements vary by more than an order of magnitude in this spectral region. The measurements reported here provide much greater spectral coverage than the most recent measurements. We report a minimum absorption cross section of 3.4×10-24 cm2 at 381.8 nm, which is 22 % lower than the previously reported value. The effect of O3 concentration and water vapor partial pressure were investigated, however there were no observable changes in the absorption spectrum most likely due to the low optical density of the complex.
Bioconcentration of TNT and RDX in coastal marine biota.
Ballentine, Mark; Tobias, Craig; Vlahos, Penny; Smith, Richard; Cooper, Christopher
2015-05-01
The bioconcentration factor (BCF) was measured for 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in seven different marine species of varying trophic levels. Time series and concentration gradient treatments were used for water column and tissue concentrations of TNT, RDX, and their environmentally important derivatives 2-amino-4,6-dintrotoluene (2-ADNT) and 4-amino-2,6-dinitrotoluene (4-ADNT). BCF values ranged from 0.0031 to 484.5 mL g(-1) for TNT and 0.023 to 54.83 mL g(-1) for RDX. The use of log K ow value as an indicator was evaluated by adding marine data from this study to previously published data. For the munitions in this study, log K ow value was a good indicator in the marine environment. The initial uptake and elimination rates of TNT and RDX for Fucus vesiculosus were 1.79 and 0.24 h(-1) for TNT and 0.50 and 0.0035 h(-1) for RDX respectively. Biotransformation was observed in all biota for both TNT and RDX. Biotransformation of TNT favored 4-ADNT over 2-ADNT at ratios of 2:1 for F. vesiculosus and 3:1 for Mytilus edulis. Although RDX derivatives were measureable, the ratios of RDX derivatives were variable with no detectable trend. Previous approaches for measuring BCF in freshwater systems compare favorably with these experiments with marine biota, yet significant gaps on the ultimate fate of munitions within the biota exist that may be overcome with the use stable isotope-labeled munitions substrates.
Interpretation of ESR results for some semimagnetic semiconductor alloys
NASA Astrophysics Data System (ADS)
Woolley, J. C.; Chehab, S. F.; Donofrio, T.; Manhas, S.; Manoogian, A.; Lamarche, G.
1987-03-01
Previously reported values of the ESR linewidth variation with temperature for the alloys (i) Cd xZn yMn zSe (ii) Cd xZn yMn zTe and (iii) Cd 1- zMn zTe 1- ySe y have been analyzed in terms of the relation, δ H = Γ exp (- T/ T0) + B{1 - exp(- T/ T0)}(1-θ/ T), where the first term is attributed to spatial inhomogeneity effects and the second to paramagnetic behaviour. Values of the parameters, Γ, T0 and B have been determined as a function of composition in each alloy system. The parameter T0, which measures the potential barrier separating two neighbouring ground states of the disordered spin system, is found to satisfy the relation T0 = (α + β f) z, where f = y/( x + y) for (i) and (ii) and f = y for (iii). β is positive for (i) and (ii) and negative for (iii), consistent with previous suggestions of Kremer and Furdyna, and may be correlated with the exchange constants Jsp-d discussed by Hass et al. The parameter Γ, which measures the width of the distribution of the local field seen by manganese ions in the lattice, is found to satisfy the relation Γ = Dz2(1 - z), where D appears to be characteristic of the crystal structure. The parameter B which measures the linewidth δ H at high temperatures due to paramagnetic effects is found to vary as B = B0 + γ z and the values of the coefficient γ appear to be related to the exchange parameters of the materials.
Roberts, M. S.; Jacobs, J. W.
2015-12-07
Rayleigh–Taylor instability experiments are performed using both immiscible and miscible incompressible liquid combinations having a relatively large Atwood number ofmore » $$A\\equiv ({\\it\\rho}_{2}-{\\it\\rho}_{1})/({\\it\\rho}_{2}+{\\it\\rho}_{1})=0.48$$. The liquid-filled tank is attached to a test sled that is accelerated downwards along a vertical rail system using a system of weights and pulleys producing approximately$1g$$net acceleration. The tank is backlit and images are digitally recorded using a high-speed video camera. The experiments are either initiated with forced initial perturbations or are left unforced. The forced experiments have an initial perturbation imposed by vertically oscillating the liquid-filled tank to produce Faraday waves at the interface. The unforced experiments rely on random interfacial fluctuations, resulting from background noise, to seed the instability. The main focus of this study is to determine the effects of forced initial perturbations and the effects of miscibility on the growth parameter,$${\\it\\alpha}$$. Measurements of the mixing-layer width,$$h$$, are acquired, from which$${\\it\\alpha}$$is determined. It is found that initial perturbations of the form used in this study do not affect measured$${\\it\\alpha}$$values. However, miscibility is observed to strongly affect$${\\it\\alpha}$$, resulting in a factor of two reduction in its value, a finding not previously observed in past experiments. In addition, all measured$${\\it\\alpha}$values are found to be smaller than those obtained in previous experimental studies.« less
Novel Polymers Containing Metal Ligands in the Side Chain
2012-10-01
10 2011): 0. doi: 10.1021/bm2010142 2012/10/01 15:35:02 10 Jun Cui, Melissa A. Lackey, Ahmad E. Madkour , Erika M. Saffer, David M. Griffin, Surita R...values for the linear fits are around 0.98. [M] denotes the monomer concentration. M- H measurement. If the RTF behavior of the previously...magnetization as a function of the applied field (M- H ) was measured at room temperature by a superconducting quantum interference device (SQUID) for all of
Collisionless dissociation and isotopic enrichment of SF6 using high-powered CO2 laser radiation
NASA Technical Reports Server (NTRS)
Gower, M. C.; Billman, K. W.
1977-01-01
Dissociation of S-32F6 and the resultant isotopic enrichment of S-34F6 using high-powered CO2 laser radiation has been studied with higher experimental sensitivity than previously reported. Enrichment factors have been measured as a function of laser pulse number, wavelength, energy and time duration. A geometry independent dissociation cross section is introduced and measured values are presented. Threshold energy densities, below which no dissociation was observed, were also determined.
Intensity formulas for triplet bands
NASA Technical Reports Server (NTRS)
Budo, A.
1982-01-01
Previous work in this area is surveyed and the mathematics involved in determining the quantitative intensity measurements in triplet bands is presented. Explicit expressions for the intensity distribution in the branches of the 3 Sigma-3 Pi and 1 Sigma-3Pi bands valid for all values of the coupling constant Y of the 3 Pi terms are given. The intensity distribution calculated according to the formulas given is compared with measurements of PH, 3 Pi-3 Sigma. Good quantitative agreement is obtained.
Potential Therapeutic Use of Relaxin in Healing Cranial Bone Defects
2017-09-01
to measure circulating concentrations of relaxin during the infusion by ELISA ; 3. sacrifice the mice at 10-12 days after cranial defect; 4. fix the...osmotic pump for 10-12 days, and to measure circulating concentrations of relaxin during the infusion by ELISA . Values of 0.35, 0.69, 1.61, 0.66, 1.99...vehicle-infused mice, because in our previous work, none was detected. This makes sense, because the ELISA we use does not detect mouse relaxin
Surface tension profiles in vertical soap films
NASA Astrophysics Data System (ADS)
Adami, N.; Caps, H.
2015-01-01
Surface tension profiles in vertical soap films are experimentally investigated. Measurements are performed by introducing deformable elastic objets in the films. The shape adopted by those objects once set in the film is related to the surface tension value at a given vertical position by numerically solving the adapted elasticity equations. We show that the observed dependency of the surface tension versus the vertical position is predicted by simple modeling that takes into account the mechanical equilibrium of the films coupled to previous thickness measurements.
Strong electromagnetic pulses generated in high-intensity laser-matter interactions
NASA Astrophysics Data System (ADS)
Rączka, P.; Dubois, J.-L.; Hulin, S.; Rosiński, M.; Zaraś-Szydłowska, A.; Badziak, J.
2018-01-01
Results are reported of an experiment performed at the Eclipse laser facility in CELIA, Bordeaux, on the generation of strong electromagnetic pulses. Measurements were performed of the target neutralization current, the total target charge and the tangential component of the magnetic field for the laser energies ranging from 45 mJ to 92 mJ with the pulse duration approximately 40 fs, and for the pulse durations ranging from 39 fs to 1000 fs, with the laser energy approximately 90 mJ. It was found that the values obtained for thick (mm scale) Cu targets are visibly higher than values reported in previous experiments, which is argued to be a manifestation of a strong dependence of the target electric polarization process on the laser contrast and hence on the amount of preplasma. It was also found that values obtained for thin (μm scale) Al foils were visibly higher than values for thick Cu targets, especially for pulse durations longer than 100 fs. The correlations between the total target charge versus the maximum value of the target neutralization current, and the maximum value of the tangential component of the magnetic field versus the total target charge were analysed. They were found to be in very good agreement with correlations seen in data from previous experiments, which provides a good consistency check on our experimental procedures.
CT radiation profile width measurement using CR imaging plate raw data
Yang, Chang‐Ying Joseph
2015-01-01
This technical note demonstrates computed tomography (CT) radiation profile measurement using computed radiography (CR) imaging plate raw data showing it is possible to perform the CT collimation width measurement using a single scan without saturating the imaging plate. Previously described methods require careful adjustments to the CR reader settings in order to avoid signal clipping in the CR processed image. CT radiation profile measurements were taken as part of routine quality control on 14 CT scanners from four vendors. CR cassettes were placed on the CT scanner bed, raised to isocenter, and leveled. Axial scans were taken at all available collimations, advancing the cassette for each scan. The CR plates were processed and raw CR data were analyzed using MATLAB scripts to measure collimation widths. The raw data approach was compared with previously established methodology. The quality control analysis scripts are released as open source using creative commons licensing. A log‐linear relationship was found between raw pixel value and air kerma, and raw data collimation width measurements were in agreement with CR‐processed, bit‐reduced data, using previously described methodology. The raw data approach, with intrinsically wider dynamic range, allows improved measurement flexibility and precision. As a result, we demonstrate a methodology for CT collimation width measurements using a single CT scan and without the need for CR scanning parameter adjustments which is more convenient for routine quality control work. PACS numbers: 87.57.Q‐, 87.59.bd, 87.57.uq PMID:26699559
NASA Astrophysics Data System (ADS)
Bennett, D. P.; Bond, I. A.; Abe, F.; Asakura, Y.; Barry, R.; Bhattacharya, A.; Donachie, M.; Evans, P.; Fukui, A.; Hirao, Y.; Itow, Y.; Koshimoto, N.; Li, M. C. A.; Ling, C. H.; Masuda, K.; Matsubara, Y.; Muraki, Y.; Nagakane, M.; Ohnishi, K.; Ranc, C.; Rattenbury, N. J.; Saito, To.; Sharan, A.; Sullivan, D. J.; Sumi, T.; Suzuki, D.; Tristram, P. J.; Yamada, T.; Yamada, T.; Yonehara, A.; MOA Collaboration
2017-08-01
We present the MOA Collaboration light-curve data for the planetary microlensing event OGLE-2015-BLG-0954, which was previously announced in a paper by the KMTNet and OGLE Collaborations. The MOA data cover the caustic exit, which was not covered by the KMTNet or Optical Gravitational Lensing Experiment (OGLE) data, and they provide a more reliable measurement of the finite source effect. The MOA data also provide a new source color measurement that reveals a lens-source relative proper motion of μ rel = 11.8 ± 0.8 mas yr-1, which compares to the value of μ rel = 18.4 ± 1.7 mas yr-1 reported in the KMTNet-OGLE paper. This new MOA value for μ rel has an a priori probability that is a factor of ≳100 times larger than the previous value, and it does not require a lens system distance of D L < 1 kpc. Based on the corrected source color, we find that the lens system consists of a planet of mass {3.4}-1.6+3.7 {M}{Jup} orbiting a {0.30}-0.14+0.34 {M}⊙ star at an orbital separation of {2.1}-1.0+2.2 {au} and a distance of {1.2}-0.5+1.1 {kpc}.
NASA Astrophysics Data System (ADS)
Haeussler, P. J.
2003-12-01
We revised the preliminary slip distribution (Science, 2003, v. 300, p. 1037ff) along the Denali and Totschunda faults after additional fieldwork this summer. Features of the surface trace had degraded in places due to melting of snow, permafrost, and soil. However, without snow cover, offset of fine-scale features was much clearer at many new localities. We were also able to add additional measurements on glaciers, where offset snow-filled crevasses could be observed. As a result, the revised slip distribution provides considerably more detail and a higher level of confidence than that inferred solely from measurements collected immediately after the earthquake. The primary features of the revised slip distribution are: 1) a broad plateau of roughly 5-m offsets extending from 70 to 170 km east of the epicenter along the central part of the Denali fault, 2) high-slip values of 6.5-8+ m between 170 and 212 km east of the epicenter, 3) the step up from the 5 m plateau to the higher is sharp, occurring over a lateral distance of one kilometer, 4) there are three new, and anomalously high, measurements of 7.2-8.2 m along a 7-km length of the fault within the plateau of 5-m slip values, 5) there was a maximum 3-m offset on the Totschunda fault, which is 0.9-m higher than previously measured; 6) A previously inferred region of high slip in the vicinity of the Trans Alaska Pipeline is less obvious or absent. However, slip in that area is higher than the region to the west of the Delta River, 7) In contrast to geodetic and seismologic slip models that infer low slip and moment release in a zone 100-160 km east of the epicenter, we find continuous surface offsets of about 5 m; 8) A drop to zero slip, previously inferred at the Totschunda-Denali junction appears to be a result of slip values obtained from transfer structures. The smallest robust measurements of lateral slip in the transition zone were about a meter. Denali Fault Earthquake Geology Working Group : T. Dawson, P. Haeussler, J. Lienkaemper, A. Matmon, D. Schwartz, H.Stenner, B. Sherrod (USGS), F. Cinti, P. Montone (INGV, Rome)
Glycaemic index and glycaemic load values of commonly consumed foods in the United Arab Emirates.
Al Dhaheri, Ayesha S; Henry, C Jeyakumar K; Mohamad, Maysm N; Ohuma, Eric O; Ismail, Leila Cheikh; Al Meqbaali, Fatima T; Jarrar, Amjad H
2017-04-01
Glycaemic index (GI) and glycaemic load (GL) values of some commonly consumed foods in the United Arab Emirates were determined with an aim of adding these values to the existing international table of GI and GL values. In all, eighteen test foods categorised into breads (n 5), entrée dishes (n 3), main dishes (n 5) and sweet dishes (n 5) were tested. For each test food, at least fifteen healthy participants consumed 25 or 50 g available carbohydrate portions of a reference food (glucose), which was tested three times, and a test food after an overnight fast, was tested once, on separate occasions. Capillary blood samples were obtained by finger-prick and blood glucose was measured using clinical chemistry analyser. A fasting blood sample was obtained at baseline and before consumption of test foods. Additional blood samples were obtained at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI value of each test food was calculated as the percentage of the incremental area under the blood glucose curve (IAUC) for the test food of each participant divided by the average IAUC for the reference food of the same participant. The GI values of tested foods ranged from low (55 or less) to high (70 or more). The GI values of various breads and rice-containing dishes were comparable with previously published values. This study provides GI and GL values of previously untested traditional Emirati foods which could provide a useful guide on dietary recommendations for the Emirati population.
NASA Astrophysics Data System (ADS)
Waelkens, C. M.; Gonzalez, C.; Martineau, D.; Goff, F. E.; Stix, J.
2017-12-01
Large silicic caldera-forming eruptions are some of the most destructive events on our planet, which makes silicic calderas important systems to study. Volatiles play an important role in determining the nature and behaviour of magmas, and can trigger eruptions when changes in volatile content and exsolution of fluid phases lead to overpressure in the magma chamber. A separate fluid phase will be exsolved if the magma is fluid saturated; whether the magma is fluid saturated depends on its H2O and CO2 content. We measured H2O and CO2 in melt inclusions of the Valles Caldera supervolcano system in New Mexico. This system had super-eruptions at 1.64 Ma and 1.25 Ma, depositing respectively the Lower (Otowi Member) and the Upper (Tshirege Member) Bandelier Tuff. Previous studies have reported H2O values for the Bandelier Tuff and the Cerro Toledo Formation - erupted between the two Bandelier super-eruptions from the same magma reservoir. We expanded this dataset and added CO2 analyses, which gives a more complete image of the volatile saturation state of the magma. Both H2O and CO2 were measured by transmission FTIR on doubly-polished melt inclusions hosted in quartz and feldspar crystals. While we found only limited variation within H2O contents, CO2 values were found to vary strongly. Our preliminary results indicate H2O values of 4 to 6 wt % throughout both the Lower and Upper Bandelier Tuff, consistent with previous studies. In contrast, we found CO2 values vary strongly, from below 50 ppm (maximum measured 60 ppm, minimum 7 ppm, median 33 ppm) in the base of the Lower Bandelier Tuff to 100 - 200 ppm CO2 (maximum measured 234 ppm, minimum 44, median 118 ppm) in the top of the basal Plinian fall deposit (Guaje Pumice). By the end of the Cerro Toledo Rhyolite and beginning of the Upper Bandelier, CO2 values in the magma were low again, around 50 ppm (maximum measured 91 ppm, minimum 23 ppm, median 42 ppm). No substantial difference is observed in H2O and CO2 values between the end of the Cerro Toledo Formation and beginning of the Upper Bandelier Tuff. We hypothesise that these variations in CO2 are related to the input of hotter, CO2-richer magma into the Bandelier magma chamber.
Royston, Thomas J.; Dai, Zoujun; Chaunsali, Rajesh; Liu, Yifei; Peng, Ying; Magin, Richard L.
2011-01-01
Previous studies of the first author and others have focused on low audible frequency (<1 kHz) shear and surface wave motion in and on a viscoelastic material comprised of or representative of soft biological tissue. A specific case considered has been surface (Rayleigh) wave motion caused by a circular disk located on the surface and oscillating normal to it. Different approaches to identifying the type and coefficients of a viscoelastic model of the material based on these measurements have been proposed. One approach has been to optimize coefficients in an assumed viscoelastic model type to match measurements of the frequency-dependent Rayleigh wave speed. Another approach has been to optimize coefficients in an assumed viscoelastic model type to match the complex-valued frequency response function (FRF) between the excitation location and points at known radial distances from it. In the present article, the relative merits of these approaches are explored theoretically, computationally, and experimentally. It is concluded that matching the complex-valued FRF may provide a better estimate of the viscoelastic model type and parameter values; though, as the studies herein show, there are inherent limitations to identifying viscoelastic properties based on surface wave measurements. PMID:22225067
Tablet Velocity Measurement and Prediction in the Pharmaceutical Film Coating Process.
Suzuki, Yasuhiro; Yokohama, Chihiro; Minami, Hidemi; Terada, Katsuhide
2016-01-01
The purpose of this study was to measure the tablet velocity in pan coating machines during the film coating process in order to understand the impact of the batch size (laboratory to commercial scale), coating machine type (DRIACOATER, HICOATER® and AQUA COATER®) and manufacturing conditions on tablet velocity. We used a high speed camera and particle image velocimetry to measure the tablet velocity in the coating pans. It was observed that increasing batch sizes resulted in increased tablet velocities under the same rotation number because of the differences in circumferential rotation speeds. We also observed the tendency that increase in the filling ratio of tablets resulted in an increased tablet velocity for all coating machines. Statistical analysis was used to make a tablet velocity predictive equation by employing the filling ratio and rotation speed as the parameters from these measured values. The correlation coefficients of predicted value and experimental value were more than 0.959 in each machine. Using the predictive equation to determine tablet velocities, the manufacturing conditions of previous products were reviewed, and it was found that the tablet velocities of commercial scales, in which tablet chipping and breakage problems had occurred, were higher than those of pilot scales or laboratory scales.
NASA Astrophysics Data System (ADS)
Connolly, D.; O'Malley, P. D.; Akers, C.; Chen, A. A.; Christian, G.; Davids, B.; Erikson, L.; Fallis, J.; Fulton, B. R.; Greife, U.; Hager, U.; Hutcheon, D. A.; Ilyushkin, S.; Laird, A. M.; Mahl, A.; Ruiz, C.
2018-03-01
Background: Nucleosynthesis of mid-mass elements is thought to occur under hot and explosive astrophysical conditions. Radiative α capture on 34S has been shown to impact nucleosynthesis in several such conditions, including core and shell oxygen burning, explosive oxygen burning, and type Ia supernovae. Purpose: Broad uncertainties exist in the literature for the strengths of three resonances within the astrophysically relevant energy range (ECM=1.94 -3.42 MeV at T =2.2 GK ). Further, there are several states in 38Ar within this energy range which have not been previously measured. This work aimed to remeasure the resonance strengths of states for which broad uncertainty existed as well as to measure the resonance strengths and energies of previously unmeasured states. Methods: Resonance strengths and energies of eight narrow resonances (five of which had not been previously studied) were measured in inverse kinematics with the DRAGON facility at TRIUMF by impinging an isotopically pure beam of 34S ions on a windowless 4He gas target. Prompt γ emissions of de-exciting 38Ar recoils were detected in an array of bismuth germanate scintillators in coincidence with recoil nuclei, which were separated from unreacted beam ions by an electromagnetic mass separator and detected by a time-of-flight system and a multianode ionization chamber. Results: The present measurements agree with previous results. Broad uncertainty in the resonance strength of the ECM=2709 keV resonance persists. Resonance strengths and energies were determined for five low-energy resonances which had not been studied previously, and their strengths were determined to be significantly weaker than those of previously measured resonances. Conclusions: The five previously unmeasured resonances were found not to contribute significantly to the total thermonuclear reaction rate. A median total thermonuclear reaction rate calculated using data from the present work along with existing literature values using the STARLIB rate calculator agrees with the NON-SMOKER statistical model calculation as well as the REACLIB and STARLIB library rates at explosive and nonexplosive oxygen-burning temperatures (T =3 -4 GK and T =1.5 -2.7 GK , respectively).
Missing Value Monitoring Enhances the Robustness in Proteomics Quantitation.
Matafora, Vittoria; Corno, Andrea; Ciliberto, Andrea; Bachi, Angela
2017-04-07
In global proteomic analysis, it is estimated that proteins span from millions to less than 100 copies per cell. The challenge of protein quantitation by classic shotgun proteomic techniques relies on the presence of missing values in peptides belonging to low-abundance proteins that lowers intraruns reproducibility affecting postdata statistical analysis. Here, we present a new analytical workflow MvM (missing value monitoring) able to recover quantitation of missing values generated by shotgun analysis. In particular, we used confident data-dependent acquisition (DDA) quantitation only for proteins measured in all the runs, while we filled the missing values with data-independent acquisition analysis using the library previously generated in DDA. We analyzed cell cycle regulated proteins, as they are low abundance proteins with highly dynamic expression levels. Indeed, we found that cell cycle related proteins are the major components of the missing values-rich proteome. Using the MvM workflow, we doubled the number of robustly quantified cell cycle related proteins, and we reduced the number of missing values achieving robust quantitation for proteins over ∼50 molecules per cell. MvM allows lower quantification variance among replicates for low abundance proteins with respect to DDA analysis, which demonstrates the potential of this novel workflow to measure low abundance, dynamically regulated proteins.
Markham, Wolfgang A; Young, Robert; Sweeting, Helen; West, Patrick; Aveyard, Paul
2012-07-01
Previous studies found lower substance use in schools achieving better examination and truancy results than expected, given their pupil populations (high value-added schools). This study examines whether these findings are replicated in West Scotland and whether school ethos indicators focussing on pupils' perceptions of schooling (environment, involvement, engagement and teacher-pupil relations) mediate the associations. Teenagers from forty-one schools (S2, aged 13, n = 2268; S4, aged 15, n = 2096) previously surveyed in primary school (aged 11, n = 2482) were surveyed in the late 1990s. School value-added scores were derived from standardised residuals of two regression equations separately predicting from pupils' socio-demographic characteristics (1) proportions of pupils passing five Scottish Standard Grade Examinations, and (2) half-day truancy loss. Outcomes were current smoking, monthly drinking, ever illicit drug use. Random effects logistic regression models adjusted for potential pupil-level confounders were used to assess (1) associations between substance use and school-level value-added scores and (2) whether these associations were mediated by pupils' perceptions of schooling or other school-level factors (school roll, religious denomination and mean aggregated school-level ethos scores). Against expectations, value-added education was positively associated with smoking (Odds Ratios [95% confidence intervals] for one standard deviation increase in value-added scores were 1.28 [1.02-1.61] in S2 and 1.13 [1.00-1.27] in S4) and positively but weakly and non-significantly associated with drinking and drug use. Engagement and positive teacher-pupil relations were strongly and negatively associated with all substance use outcomes at both ages. Other school-level factors appeared weakly and largely non-significantly related to substance use. Value-added scores were unrelated to school ethos measures and no ethos measure mediated associations between value-added education and substance use. We conclude that substance use in Scotland is more likely in high value-added schools, among disengaged students and those with poorer student-teacher relationships. Understanding the underpinning mechanisms is a potentially important public health concern. Copyright © 2012 Elsevier Ltd. All rights reserved.
Markham, Wolfgang A.; Young, Robert; Sweeting, Helen; West, Patrick; Aveyard, Paul
2012-01-01
Previous studies found lower substance use in schools achieving better examination and truancy results than expected, given their pupil populations (high value-added schools). This study examines whether these findings are replicated in West Scotland and whether school ethos indicators focussing on pupils' perceptions of schooling (environment, involvement, engagement and teacher–pupil relations) mediate the associations. Teenagers from forty-one schools (S2, aged 13, n = 2268; S4, aged 15, n = 2096) previously surveyed in primary school (aged 11, n = 2482) were surveyed in the late 1990s. School value-added scores were derived from standardised residuals of two regression equations separately predicting from pupils' socio-demographic characteristics (1) proportions of pupils passing five Scottish Standard Grade Examinations, and (2) half-day truancy loss. Outcomes were current smoking, monthly drinking, ever illicit drug use. Random effects logistic regression models adjusted for potential pupil-level confounders were used to assess (1) associations between substance use and school-level value-added scores and (2) whether these associations were mediated by pupils' perceptions of schooling or other school-level factors (school roll, religious denomination and mean aggregated school-level ethos scores). Against expectations, value-added education was positively associated with smoking (Odds Ratios [95% confidence intervals] for one standard deviation increase in value-added scores were 1.28 [1.02–1.61] in S2 and 1.13 [1.00–1.27] in S4) and positively but weakly and non-significantly associated with drinking and drug use. Engagement and positive teacher–pupil relations were strongly and negatively associated with all substance use outcomes at both ages. Other school-level factors appeared weakly and largely non-significantly related to substance use. Value-added scores were unrelated to school ethos measures and no ethos measure mediated associations between value-added education and substance use. We conclude that substance use in Scotland is more likely in high value-added schools, among disengaged students and those with poorer student–teacher relationships. Understanding the underpinning mechanisms is a potentially important public health concern. PMID:22503837
Reflection coefficients of permeant molecules in human red cell suspensions.
Owen, J D; Eyring, E M
1975-08-01
The Staverman reflection coefficient, sigma for several permeant molecules was determined in human red cell suspensions with a Durrum stopped-flow spectrophotometer. This procedure was first used with dog, cat, and beef red cells and with human red cells. The stopped-flow technique used was similar to the rapid-flow method used by those who originally reported sigma measurements in human red cells for molecules which rapidly penetrate the red cell membrane. The sigma values we obtained agreed with those previously reported for most of the slow penetrants, except malonamide, but disagreed with all the sigma values previously reported for the rapid penetrants. We were unable to calculate an "equivalent pore radius" with our sigma data. The advantages of our equipment and our experimental procedure are discussed. Our sigma data suggest that sigma is indirectly proportional to the log of the nonelectrolyte permeability coefficient, omega. Since a similar trend has been previously shown for log omega and molar volume of the permeant molecules, a correlatioo was shown between sigma and molar volume suggesting the membrane acts as a sieve.
An Astrometric Observation of Binary Star System WDS 15559-0210 at the Great Basin Observatory
NASA Astrophysics Data System (ADS)
Musegades, Lila; Niebuhr, Cole; Graham, Mackenzie; Poore, Andrew; Freed, Rachel; Kenney, John; Genet, Russell
2018-04-01
Researchers at Concordia University Irvine measured the position angle and separation of the double star system WDS 15559-0210 using a SBIG STX-16803 CCD camera on the PlaneWave 0.7-m CDK 700 telescope at the Great Basin Observatory. Images of the binary star system were measured using AstroImageJ software. Twenty observations of WDS 15559-0210 were measured and analyzed. The calculated mean resulted in a position angle of 345.95° and a separation of 5.94". These measurements were consistent with the previous values for this binary system listed in the Washington Double Star Catalog.
Physiological Parameter Response to Variation of Mental Workload.
Marinescu, Adrian Cornelius; Sharples, Sarah; Ritchie, Alastair Campbell; Sánchez López, Tomas; McDowell, Michael; Morvan, Hervé P
2018-02-01
To examine the relationship between experienced mental workload and physiological response by noninvasive monitoring of physiological parameters. Previous studies have examined how individual physiological measures respond to changes in mental demand and subjective reports of workload. This study explores the response of multiple physiological parameters and quantifies their added value when estimating the level of demand. The study presented was conducted in laboratory conditions and required participants to perform a visual-motor task that imposed varying levels of demand. The data collected consisted of physiological measurements (heart interbeat intervals, breathing rate, pupil diameter, facial thermography), subjective ratings of workload (Instantaneous Self-Assessment Workload Scale [ISA] and NASA-Task Load Index), and the performance. Facial thermography and pupil diameter were demonstrated to be good candidates for noninvasive workload measurements: For seven out of 10 participants, pupil diameter showed a strong correlation ( R values between .61 and .79 at a significance value of .01) with mean ISA normalized values. Facial thermography measures added on average 47.7% to the amount of variability in task performance explained by a regression model. As with the ISA ratings, the relationship between the physiological measures and performance showed strong interparticipant differences, with some individuals demonstrating a much stronger relationship between workload and performance measures than others. The results presented in this paper demonstrate that physiological and pupil diameter can be used for noninvasive real-time measurement of workload. The methods presented in this article, with current technological capabilities, are better suited for workplaces where the person is seated, offering the possibility of being applied to pilots and air traffic controllers.
NASA Astrophysics Data System (ADS)
Kirsch, Leo E.; Devlin, M.; Mosby, S. M.; Gomez, J. A.
2017-12-01
A new measurement is presented of the 6Li(n, α)t cross section from 245 keV to 10 MeV using a 252Cf fission chamber with 6LiI(Eu) and Cs2LiYCl6:Ce (CLYC) scintillators which act as both target and detector. Neutron energies are determined from the time of flight (TOF) method using the signals from spontaneous fission and reaction product recoil. Simulations of neutron downscatter in the crystals and fission chamber bring 6Li(n, α)t cross section values measured with the 6LiI(Eu) into agreement with previous experiments and evaluations, except for two resonances at 4.2 and 6.5 MeV introduced by ENDF/B-VII.1. Suspected neutron transport modeling issues cause the cross section values obtained with CLYC to be discrepant above 2 MeV.
Blainey, Joan B.; Ferré, Ty P.A.; Cordova, Jeffrey T.
2007-01-01
Pumping of an unconfined aquifer can cause local desaturation detectable with high‐resolution gravimetry. A previous study showed that signal‐to‐noise ratios could be predicted for gravity measurements based on a hydrologic model. We show that although changes should be detectable with gravimeters, estimations of hydraulic conductivity and specific yield based on gravity data alone are likely to be unacceptably inaccurate and imprecise. In contrast, a transect of low‐quality drawdown data alone resulted in accurate estimates of hydraulic conductivity and inaccurate and imprecise estimates of specific yield. Combined use of drawdown and gravity data, or use of high‐quality drawdown data alone, resulted in unbiased and precise estimates of both parameters. This study is an example of the value of a staged assessment regarding the likely significance of a new measurement method or monitoring scenario before collecting field data.
The Rydberg constant and proton size from atomic hydrogen
NASA Astrophysics Data System (ADS)
Beyer, Axel; Maisenbacher, Lothar; Matveev, Arthur; Pohl, Randolf; Khabarova, Ksenia; Grinin, Alexey; Lamour, Tobias; Yost, Dylan C.; Hänsch, Theodor W.; Kolachevsky, Nikolai; Udem, Thomas
2017-10-01
At the core of the “proton radius puzzle” is a four-standard deviation discrepancy between the proton root-mean-square charge radii (rp) determined from the regular hydrogen (H) and the muonic hydrogen (µp) atoms. Using a cryogenic beam of H atoms, we measured the 2S-4P transition frequency in H, yielding the values of the Rydberg constant R∞ = 10973731.568076(96) per meterand rp = 0.8335(95) femtometer. Our rp value is 3.3 combined standard deviations smaller than the previous H world data, but in good agreement with the µp value. We motivate an asymmetric fit function, which eliminates line shifts from quantum interference of neighboring atomic resonances.
NASA Technical Reports Server (NTRS)
Sinyuk, Alexander; Torres, Omar; Dubovik, Oleg; Bhartia, P. K. (Technical Monitor)
2002-01-01
We present a method for retrieval of the imaginary part of refractive index of desert dust aerosol in the near UV part of spectrum. The method uses Total Ozone Mapping Spectrometer (TOMS) measurements of the top of the atmosphere radiances at 331 and 360 run and aerosol optical depth provided by the Aerosol Robotic Network (AERONET). Obtained values of imaginary part of refractive index retrieved for Saharan dust aerosol at 360 nm are significantly lower than previously reported values. The average retrieved values vary between 0.0054 and 0.0066 for different geographical locations. Our findings are in good agreement with the results of several recent investigations.
Movement asymmetry in working polo horses.
Pfau, T; Parkes, R S; Burden, E R; Bell, N; Fairhurst, H; Witte, T H
2016-07-01
The high, repetitive demands imposed on polo horses in training and competition may predispose them to musculoskeletal injuries and lameness. To quantify movement symmetry and lameness in a population of polo horses, and to investigate the existence of a relationship with age. Convenience sampled cross-sectional study. Sixty polo horses were equipped with inertial measurement units (IMUs) attached to the poll, and between the tubera sacrale. Six movement symmetry measures were calculated for vertical head and pelvic displacement during in-hand trot and compared with values for perfect symmetry, compared between left and right limb lame horses, and compared with published thresholds for lameness. Regression lines were calculated as a function of age of horse. Based on 2 different sets of published asymmetry thresholds 52-53% of the horses were quantified with head movement asymmetry and 27-50% with pelvic movement asymmetry resulting in 60-67% of horses being classified with movement asymmetry outside published guideline values for either the forelimbs, hindlimbs or both. Neither forelimb nor hindlimb asymmetries were preferentially left or right sided, with directional asymmetry values across all horses not different from perfect symmetry and absolute values not different between left and right lame horses (P values >0.6 for all forelimb symmetry measures and >0.2 for all hindlimb symmetry measures). None of the symmetry parameters increased or decreased significantly with age. A large proportion of polo horses show gait asymmetries consistent with previously defined thresholds for lameness. These do not appear to be lateralised or associated with age. © 2015 EVJ Ltd.
A dynamic model for plant growth: validation study under changing temperatures
NASA Technical Reports Server (NTRS)
Wann, M.; Raper, C. D. Jr; Raper CD, J. r. (Principal Investigator)
1984-01-01
A dynamic simulation model to describe vegetative growth of plants, for which some functions and parameter values have been estimated previously by optimization search techniques and numerical experimentation based on data from constant temperature experiments, is validated under conditions of changing temperatures. To test the predictive capacity of the model, dry matter accumulation in the leaves, stems, and roots of tobacco plants (Nicotiana tabacum L.) was measured at 2- or 3-day intervals during a 5-week period when temperatures in controlled-environment rooms were programmed for changes at weekly and daily intervals and in ascending or descending sequences within a range of 14 to 34 degrees C. Simulations of dry matter accumulation and distribution were carried out using the programmed changes for experimental temperatures and compared with the measured values. The agreement between measured and predicted values was close and indicates that the temperature-dependent functional forms derived from constant-temperature experiments are adequate for modelling plant growth responses to conditions of changing temperatures with switching intervals as short as 1 day.
Tan, Chun Hua; Huang, Zhen Jian; Huang, Xu Guang
2010-06-01
We describe a simple and rapid method for determining the critical micelle concentration (CMC) of surfactants from fiber-optic measurements of refractive index. The refractive index of an aqueous surfactant solution was monitored as the surfactant concentration was increased using an automated dispensing system. On reaching the surfactant's CMC value, an abrupt change was observed in the rate of increase of the refractive index with increasing concentration. The measurement system provides rapid semiautomatic data collection and analysis, increasing the precision, sensitivity, and range of applicability of the technique while substantially decreasing the amount of manual intervention required. Measurements of CMC for sodium dodecyl sulfate (8.10mM), cetyltrimethylammonium chloride (1.58mM), and Triton X-100 (0.21mM) were in excellent agreement with values previously reported in the literature. The method is applicable to cationic, anionic, and nonionic surfactants, and it offers a facile, in situ, and sensitive means of detecting micelle formation over a broad range of CMC values larger than 10(-1)mM. Copyright 2010 Elsevier Inc. All rights reserved.
Ventilation-perfusion distribution in normal subjects.
Beck, Kenneth C; Johnson, Bruce D; Olson, Thomas P; Wilson, Theodore A
2012-09-01
Functional values of LogSD of the ventilation distribution (σ(V)) have been reported previously, but functional values of LogSD of the perfusion distribution (σ(q)) and the coefficient of correlation between ventilation and perfusion (ρ) have not been measured in humans. Here, we report values for σ(V), σ(q), and ρ obtained from wash-in data for three gases, helium and two soluble gases, acetylene and dimethyl ether. Normal subjects inspired gas containing the test gases, and the concentrations of the gases at end-expiration during the first 10 breaths were measured with the subjects at rest and at increasing levels of exercise. The regional distribution of ventilation and perfusion was described by a bivariate log-normal distribution with parameters σ(V), σ(q), and ρ, and these parameters were evaluated by matching the values of expired gas concentrations calculated for this distribution to the measured values. Values of cardiac output and LogSD ventilation/perfusion (Va/Q) were obtained. At rest, σ(q) is high (1.08 ± 0.12). With the onset of ventilation, σ(q) decreases to 0.85 ± 0.09 but remains higher than σ(V) (0.43 ± 0.09) at all exercise levels. Rho increases to 0.87 ± 0.07, and the value of LogSD Va/Q for light and moderate exercise is primarily the result of the difference between the magnitudes of σ(q) and σ(V). With known values for the parameters, the bivariate distribution describes the comprehensive distribution of ventilation and perfusion that underlies the distribution of the Va/Q ratio.
Bomphrey, Richard J; Taylor, Graham K; Lawson, Nicholas J; Thomas, Adrian L.R
2005-01-01
Actuator disc models of insect flight are concerned solely with the rate of momentum transfer to the air that passes through the disc. These simple models assume that an even pressure is applied across the disc, resulting in a uniform downwash distribution. However, a correction factor, k, is often included to correct for the difference in efficiency between the assumed even downwash distribution, and the real downwash distribution. In the absence of any empirical measurements of the downwash distribution behind a real insect, the values of k used in the literature have been necessarily speculative. Direct measurement of this efficiency factor is now possible, and could be used to compare the relative efficiencies of insect flight across the Class. Here, we use Digital Particle Image Velocimetry to measure the instantaneous downwash distribution, mid-downstroke, of a tethered desert locust (Schistocerca gregaria). By integrating the downwash distribution, we are thereby able to provide the first direct empirical measurement of k for an insect. The measured value of k=1.12 corresponds reasonably well with that predicted by previous theoretical studies. PMID:16849240
Further Estimates of (T-T_{90}) Close to the Triple Point of Water
NASA Astrophysics Data System (ADS)
Underwood, R.; de Podesta, M.; Sutton, G.; Stanger, L.; Rusby, R.; Harris, P.; Morantz, P.; Machin, G.
2017-03-01
Recent advances in primary acoustic gas thermometry (AGT) have revealed significant differences between temperature measurements using the International Temperature Scale of 1990, T_{90}, and thermodynamic temperature, T. In 2015, we published estimates of the differences (T-T_{90}) from 118 K to 303 K, which showed interesting behavior in the region around the triple point of water, T_TPW=273.16 K. In that work, the T_{90} measurements below T_TPW used a different ensemble of capsule standard platinum resistance thermometers (SPRTs) than the T_{90} measurements above T_TPW. In this work, we extend our earlier measurements using the same ensemble of SPRTs above and below T_TPW, enabling a deeper analysis of the slope d(T-T_{90})/dT around T_TPW. In this article, we present the results of seven AGT isotherms in the temperature range 258 K to 323 K. The derived values of (T-T_{90}) have exceptionally low uncertainties and are in good agreement with our previous data and other AGT results. We present the values (T-T_{90}) alongside our previous estimates, with the resistance ratios W( T) from two SPRTs which have been used across the full range 118 K to 323 K. Additionally, our measurements show discontinuities in d(T-T_{90})/dT at T_TPW which are consistent with the slope discontinuity in the SPRT deviation functions. Since this discontinuity is by definition non-unique, and can take a range of values including zero, we suggest that mathematical representations of (T-T_{90}), such as those in the mise en pratique for the kelvin (Fellmuth et al. in Philos Trans R Soc A 374:20150037, 2016. doi: 10.1098/rsta.2015.0037), should have continuity of d(T-T_{90})/dT at T_TPW.
NASA Astrophysics Data System (ADS)
Guillot, Sebastien; Servillat, Mathieu; Webb, Natalie A.; Rutledge, Robert E.
2013-07-01
This paper presents the measurement of the neutron star (NS) radius using the thermal spectra from quiescent low-mass X-ray binaries (qLMXBs) inside globular clusters (GCs). Recent observations of NSs have presented evidence that cold ultra dense matter—present in the core of NSs—is best described by "normal matter" equations of state (EoSs). Such EoSs predict that the radii of NSs, R NS, are quasi-constant (within measurement errors, of ~10%) for astrophysically relevant masses (M NS>0.5 M ⊙). The present work adopts this theoretical prediction as an assumption, and uses it to constrain a single R NS value from five qLMXB targets with available high signal-to-noise X-ray spectroscopic data. Employing a Markov chain Monte-Carlo approach, we produce the marginalized posterior distribution for R NS, constrained to be the same value for all five NSs in the sample. An effort was made to include all quantifiable sources of uncertainty into the uncertainty of the quoted radius measurement. These include the uncertainties in the distances to the GCs, the uncertainties due to the Galactic absorption in the direction of the GCs, and the possibility of a hard power-law spectral component for count excesses at high photon energy, which are observed in some qLMXBs in the Galactic plane. Using conservative assumptions, we found that the radius, common to the five qLMXBs and constant for a wide range of masses, lies in the low range of possible NS radii, R_NS =9.1^{+ 1.3}_{- 1.5} \\,km (90%-confidence). Such a value is consistent with low-R NS equations of state. We compare this result with previous radius measurements of NSs from various analyses of different types of systems. In addition, we compare the spectral analyses of individual qLMXBs to previous works.
Stopping power measurements with the Time-of-Flight (ToF) technique
Fontana, Cristiano L.; Chen, Chien-Hung; Crespillo, Miguel L.; ...
2015-11-10
In our review of measurements of the stopping power of ions in matter is presented along with new measurements of the stopping powers of O, Si, Ti, and Au ions in self-supporting thin foils of SiO 2, Nb 2O 5, and Ta 2O 5. Moreover, a Time-of-Flight system at the Ion Beam Materials Laboratory at the University of Tennessee, Knoxville, was used in transmission geometry in order to reduce experimental uncertainties. Finally, the resulting stopping powers show good precision and accuracy and corroborate previously quoted values in the literature. New stopping data are determined.
Stopping power measurements with the Time-of-Flight (ToF) technique
NASA Astrophysics Data System (ADS)
Fontana, Cristiano L.; Chen, Chien-Hung; Crespillo, Miguel L.; Graham, Joseph T.; Xue, Haizhou; Zhang, Yanwen; Weber, William J.
2016-01-01
A review of measurements of the stopping power of ions in matter is presented along with new measurements of the stopping powers of O, Si, Ti, and Au ions in self-supporting thin foils of SiO2, Nb2O5, and Ta2O5. A Time-of-Flight system at the Ion Beam Materials Laboratory at the University of Tennessee, Knoxville, was used in transmission geometry in order to reduce experimental uncertainties. The resulting stopping powers show good precision and accuracy and corroborate previously quoted values in the literature. New stopping data are determined.
Energy metabolism of Macaca mulatta during spaceflight
NASA Technical Reports Server (NTRS)
Hoban-Higgins, T. M.; Stein, T. P.; Dotsenko, M. A.; Korolkov, V. I.; Fuller, C. A.
2000-01-01
The mean daily energy expenditure rates of two rhesus monkeys (Macaca mulatta) were determined during spaceflight on the joint U.S./Russian Bion 11 mission by the doubly labeled water (DLW, 2H218O) method. Control values were obtained from two studies performed under flight-like conditions (n = 4). The mean inflight energy expenditure for the two Bion 11 monkeys was 81.3 kcal/kg/day, which was higher than that seen previously. The average energy expenditure (77.6 +/- 4.4 kcal/kg/day) for the four ground control monkeys was slightly lower than had been measured previously.
Manning's roughness coefficient for Illinois streams
Soong, David T.; Prater, Crystal D.; Halfar, Teresa M.; Wobig, Loren A.
2012-01-01
Manning's roughness coefficients for 43 natural and constructed streams in Illinois are reported and displayed on a U.S. Geological Survey Web site. At a majority of the sites, discharge and stage were measured, and corresponding Manning's coefficients—the n-values—were determined at more than one river discharge. The n-values discussed in this report are computed from data representing the stream reach studied and, therefore, are reachwise values. Presentation of the resulting n-values takes a visual-comparison approach similar to the previously published Barnes report (1967), in which photographs of channel conditions, description of the site, and the resulting n-values are organized for each site. The Web site where the data can be accessed and are displayed is at URL http://il.water.usgs.gov/proj/nvalues/.
Krimmel, Robert M.
2000-01-01
Mass balance and climate variables are reported for South Cascade Glacier, Washington, for the years 1986-91. These variables include air temperature, precipitation, water runoff, snow accumulation, snow and ice melt terminus position, surface level, and ice speed. Data are reduced to daily and monthly values where appropriate. The glacier-averaged values of spring snow accumulation and fall net balance given in this report differ from previous results because amore complete analysis is made. Snow accumulation values for the1986-91 period ranged from 3.54 (water equivalent) meters in 1991 to2.04 meters in 1987. Net balance values ranged from 0.07 meters in1991 to -2.06 meters in 1987. The glacier became much smaller during the 1986-91 period and retreated a cumulative 50 meters.
Challenging the ‘Big G’ measurement with atoms and light
NASA Astrophysics Data System (ADS)
Rosi, Gabriele
2016-10-01
The measurement of the Newtonian gravity constant G is a formidable task. Starting from the first determination made by Henry Cavendish in 1798, several attempts have been made in order to improve knowledge of its value. Nevertheless, despite these efforts, its uncertainty has decreased only by a factor of ten per century. Cold atom interferometry represents a conceptually different technique to challenge the G measurement, a feature that is crucial in order to identify discrepancies among previous measurements. In this review paper, after a short introduction on the traditional measurement techniques, I will describe and discuss past and ongoing G determination based on atom interferometry, highlighting for each of them the most significant aspects.
Alonso, M P; Figueiredo, A C A; Borges, F O; Elizondo, J I; Galvão, R M O; Severo, J H F; Usuriaga, O C; Berni, L A; Machida, M
2010-10-01
We present the first simultaneous measurements of the Thomson scattering and electron cyclotron emission radiometer diagnostics performed at TCABR tokamak with Alfvén wave heating. The Thomson scattering diagnostic is an upgraded version of the one previously installed at the ISTTOK tokamak, while the electron cyclotron emission radiometer employs a heterodyne sweeping radiometer. For purely Ohmic discharges, the electron temperature measurements from both diagnostics are in good agreement. Additional Alfvén wave heating does not affect the capability of the Thomson scattering diagnostic to measure the instantaneous electron temperature, whereas measurements from the electron cyclotron emission radiometer become underestimates of the actual temperature values.
NASA Astrophysics Data System (ADS)
Uemura, Y.; Tadokoro, K.; Matsuhiro, K.; Ikuta, R.
2015-12-01
The most critical issue in reducing the accuracy of seafloor positioning system, GPS/Acoustic technique, is large-scale thermal gradient of sound-speed structure [Muto et al., 2008] due to the ocean current. For example, Kuroshio Current, near our observation station, forms this structure. To improve the accuracy of seafloor benchmark position (SBP), we need to directly measure the structure frequently, or estimate it from travel time residual. The former, we repeatedly measure the sound-speed at Kuroshio axis using Underway CTD and try to apply analysis method of seafloor positioning [Yasuda et al., 2015 AGU meeting]. The latter, however, we cannot estimate the structure using travel time residual until now. Accordingly, in this study, we focus on azimuthal dependence of Estimated Mean Sound-Speed (EMSS). EMSS is defined as distance between vessel position and estimated SBP divided by travel time. If thermal gradient exists and SBP is true, EMSS should have azimuthal dependence with the assumption of horizontal layered sound-speed structure in our previous analysis method. We use the data at KMC located on the central part of Nankai Trough, Japan on Jan. 28, 2015, because on that day KMC was on the north edge of Kuroshio, where we expect that thermal gradient exists. In our analysis method, the hyper parameter (μ value) weights travel time residual and rate of change of sound speed structure. However, EMSS derived from μ value determined by Ikuta et al. [2008] does not have azimuthal dependence, that is, we cannot estimate thermal gradient. Thus, we expect SBP has a large bias. Therefore, in this study, we use another μ value and examine whether EMSS has azimuthal dependence or not. With the μ value of this study, which is 1 order of magnitude smaller than the previous value, EMSS has azimuthal dependence that is consistent with observation day's thermal gradient. This result shows that we can estimate the thermal gradient adequately. This SBP displaces 25.6 cm to the north and 11.8 cm to the east compared to previous SBP. This displacement reduces the bias of SBP and RMS of horizontal component in time series to 1/3. Therefore, determination of SBP is suitable when the thermal gradient exists on observation day and EMSS has azimuthal dependence for redetermination of μ value.
Cantinotti, Massimiliano; Giordano, Raffaele; Scalese, Marco; Murzi, Bruno; Assanta, Nadia; Spadoni, Isabella; Maura, Crocetti; Marco, Marotta; Molinaro, Sabrina; Kutty, Shelby; Iervasi, Giorgio
2017-01-01
Despite recent advances, current pediatric echocardiographic nomograms for valvular and arterial dimensions remain limited. We prospectively studied healthy Caucasian Italian children by two-dimensional (2D) echocardiography. Echocardiographic measurements for 18 valvular and arterial dimensions were performed and models were generated testing for linear, logarithmic, exponential, and square root relationships. Heteroscedasticity was accounted for by White or Breusch-Pagan test. Age, weight, height, heart rate, and body surface area (BSA) were used as independent variables in different analyses to predict the mean values of each measurement. Structured Z-scores were then computed. In all, 1151 subjects (age 0 days to 17 years; 45% females; BSA 0.12-2.12m 2 ) were studied. The Haycock formula was used when presenting data as predicted values (mean±2 SDs) for a given BSA and within equations relating echocardiographic measurements to BSA. The predicted values and Z-score boundaries for all measurements are presented. We report echocardiographic nomograms for valvular and arterial dimensions derived from a large population of children. Integration of these data with those of previous reports would allow for a comprehensive coverage of pediatric 2D echocardiographic nomograms for measurement of 2D cardiac structures. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Improved measurement of the absolute branching fraction of $$D^{+}\\rightarrow \\bar{K}^0 \\mu ^{+}\
Ablikim, M.; Achasov, M. N.; Ai, X. C.; ...
2016-07-04
Here, by analyzing 2.93 fb -1 of data collected at √s = 3.773 GeV with the BESIII detector, we measure the absolute branching fraction B(D + → K¯ 0μ +ν μ) = (8.72 ± 0.07 stat. ± 0.18 sys.)%, which is consistent with previous measurements within uncertainties but with significantly improved precision. Combining the Particle Data Group values of B(D 0 → K -μ +ν μ), B(D + → K¯ 0e +ν e), and the lifetimes of the D 0 and D + mesons with the value of B(D + → K¯ 0μ +ν μ) measured in this work, wemore » determine the following ratios of partial widths: Γ(D 0 → K -μ +ν μ)/Γ(D + → K¯ 0μ +ν μ) = 0.963 ± 0.044 and Γ(D + → K¯ 0μ +ν μ)/Γ(D + → K¯ 0e +ν e) = 0.988 ± 0.033.« less
Hypertension and blood pressure awareness among American Indians of the northern plains.
Sharlin, K S; Heath, G W; Ford, E S; Welty, T K
1993-01-01
This study compared self-reported and measured blood pressure among American Indians of the northern plains. In 1986, a group of American Indians from the northern plains was administered the Centers for Disease Control Behavioral Risk Factor Survey (which included a question about previous blood pressure measurements) and a health risk appraisal (which included blood pressure measurement). Approximately 18% of the respondents reported being told by a doctor, nurse, or other health professional that they had high blood pressure, and 11% actually had measured blood pressures of at least 140/90 mm Hg. Overall, only 50% of hypertensive participants correctly identified themselves as hypertensive (sensitivity); specificity was 92%, predictive value positive was 43%, predictive value negative was 94%, and efficiency (the proportion of individuals who correctly classified their blood pressure status as high or normal) was 87%. These findings agree with similar studies of hypertension awareness, and they indicate that lack of this awareness remains a significant problem in the fight against cardiovascular diseases and premature death among American Indians.
A Synthetic Calcite Standard for Determination of Relative Mn/Cr Sensitivity Factor
NASA Astrophysics Data System (ADS)
Fujiya, W.; Ichimura, K.; Takahata, N.; Sugiura, N.; Sano, Y.
2009-12-01
Primitive chondrites which suffered from aqueous alteration often contain carbonates such as calcites, dolomites and breunnerites. 53Mn-53Cr decay system (half-life: 3.7 Myr) is applicable to dating their precipitation and many authors have measured their Mn-Cr ages using the SIMS. However, the relative Mn/Cr sensitivity factor: RSF (measured Mn+/Cr+ ratio divided by the true ratio) is not well established due to the absence of suitable standards, therefore the ages have systematic uncertainties. We prepared a synthetic Mn and Cr bearing calcite to evaluate the Mn/Cr RSF. Here we report the technical details of preparation for the standard and its Mn/Cr RSF. We also measured the Mn/Cr RSF of San Carlos olivine which is often assumed to be the same as that of a carbonate, and compared it with that of our synthetic calcite. The Cr-bearing calcite was produced in a N2 filled closed system by the reaction Ca2+ + CO32- = CaCO3 in an aqueous solution. The reaction proceeded by continuous addition of ammonium carbonate vapor to the solution. The crystal size of the calcite was ~300 μm. A small amount of hydrazine was added to the solution in order to keep chromous ion from oxidation. Mn and Cr concentrations in the calcite grains were determined by the SEM-EDS. A weak, defocused beam was used due to prevent electron beam damage. In a spherical grain, radial zoning of Mn and Cr concentrations occur and they decrease towards the periphery. At the center of the grains, Mn and Cr concentrations are ~0.5 atomic % and the values of the Mn/Cr ratios are relatively constant. The Mn/Cr RSF was determined with the CAMECA NanoSIMS 50 at Ocean Research Institute of Univ. of Tokyo. A primary O- beam of ~1 nA and 5 μm diameter was used. 43Ca+, 52Cr+, 53Cr+ and 55Mn+ ions were analyzed in a combined peak-jumping/multi-detection mode. The total measurement time was typically ~20 minutes. The measurements were started after presputtering of 15 minutes. The mass resolution power was ~3500, sufficient to resolve all relevant isobaric interferences. Several points near the center of calcite grains with constant Mn and Cr concentrations were measured. As for San Carlos olivine, a primary beam was rastered over 20 x 20 μm2 areas. Signals of all ions decreased with time during the measurements. The 55Mn/52Cr RSF also decreased with time. Initially it was ~0.7-0.8, and approached to a nearly constant value of ~0.5-0.6 after ~20 minutes. 53Cr+/52Cr+ isotopic ratio was 0.1105 ± 0.0002 (1σ), not dependent on time and space. This value corresponds to ~-26 permil fractionation from the reference value. On the other hand, the RSF of San Carlos olivine was found to be ~0.9, consistent with previous studies. The RSF of our calcite is significantly lower than the values used in previous studies and the RSF of San Carlos olivine measured in this study. This implies that Mn-Cr ages for carbonates obtained in previous studies may have systematic biases (~3 Myr).
Tissue dielectric measurement using an interstitial dipole antenna.
Wang, Peng; Brace, Christopher L
2012-01-01
The purpose of this study was to develop a technique to measure the dielectric properties of biological tissues with an interstitial dipole antenna based upon previous efforts for open-ended coaxial probes. The primary motivation for this technique is to facilitate treatment monitoring during microwave tumor ablation by utilizing the heating antenna without additional intervention or interruption of the treatment. The complex permittivity of a tissue volume surrounding the antenna was calculated from reflection coefficients measured after high-temperature microwave heating by using a rational function model of the antenna's input admittance. Three referencing liquids were needed for measurement calibration. The dielectric measurement technique was validated ex vivo in normal and ablated bovine livers. Relative permittivity and effective conductivity were lower in the ablation zone when compared to normal tissue, consistent with previous results. The dipole technique demonstrated a mean 10% difference of permittivity values when compared to open-ended coaxial cable measurements in the frequency range of 0.5-20 GHz. Variability in measured permittivities could be smoothed by fitting to a Cole-Cole dispersion model. Further development of this technique may facilitate real-time monitoring of microwave ablation treatments through the treatment applicator. © 2011 IEEE
Tissue Dielectric Measurement Using an Interstitial Dipole Antenna
Wang, Peng; Brace, Christopher L.
2012-01-01
The purpose of this study was to develop a technique to measure the dielectric properties of biological tissues with an interstitial dipole antenna based upon previous efforts for open-ended coaxial probes. The primary motivation for this technique is to facilitate treatment monitoring during microwave tumor ablation by utilizing the heating antenna without additional intervention or interruption of the treatment. The complex permittivity of a tissue volume surrounding the antenna was calculated from reflection coefficients measured after high-temperature microwave heating by using a rational function model of the antenna’s input admittance. Three referencing liquids were needed for measurement calibration. The dielectric measurement technique was validated ex vivo in normal and ablated bovine livers. Relative permittivity and effective conductivity were lower in the ablation zone when compared to normal tissue, consistent with previous results. The dipole technique demonstrated a mean 10% difference of permittivity values when compared to open-ended coaxial cable measurements in the frequency range of 0.5–20 GHz. Variability in measured permittivities could be smoothed by fitting to a Cole–Cole dispersion model. Further development of this technique may facilitate real-time monitoring of microwave ablation treatments through the treatment applicator. PMID:21914566
What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?
Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E
2018-03-01
Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values <40 mg/dL, 58% of deleted values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values <40 mg/dL could decrease reported rates of severe hypoglycemia by as much as 40%. This project demonstrates that operators are frequently able to identify POC BG values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.
Mayrovitz, H N; Davey, S
2011-12-01
Our goal was to determine effects of low-level-laser-therapy (LLLT) on skin water and tissue indentation resistance (TIR) in patients with arm (N = 38) or leg (N = 38) lymphedema. Skin water was determined from tissue dielectric constant (TDC) measurements and TIR determined from measurements of force resulting from tissue indentations of 3-4 mm. A limb-location with fibrosis was identified by palpation and treated with an LLLT device for one minute at each of five points within a 3 cm2 area. TDC and TIR at these sites and corresponding sites on the contralateral limb were measured prior to LLLT (pre-LLLT), immediately after LLLT (post-LLLT) and after a manual lymphatic drainage (MLD) session (post-MLD). Results, from arms and legs, showed that post-LLLT values of TIR and TDC were significantly less than pre-LLLT. TIR values remained significantly reduced at post-MLD whereas TDC values were not significantly different from pre-LLLT values. On follow-up visit, 17 previously LLLT treated legs were sham treated with an inactive LLLT unit and measurements replicated. A TIR and TDC change-pattern similar to that obtained with the active LLLT was obtained, but sham-related reductions in TIR and TDC immediately post sham-treatment were significantly less than achieved with the prior active LLLT treatment.
High-resolution one-photon absorption spectroscopy of the D2Σ- ← X2 Π system of radical OH and OD
NASA Astrophysics Data System (ADS)
Heays, A. N.; de Oliveira, N.; Gans, B.; Ito, K.; Boyé-Péronne, S.; Douin, S.; Hickson, K. M.; Nahon, L.; Loison, J. C.
2018-01-01
Vacuum-ultraviolet (VUV) photoabsorption spectra were recorded of the A2Σ+(v‧ = 0) ← X2 Π(v‧‧ = 0) , D2Σ-(v‧ = 0) ← X2 Π(v‧‧ = 0) and D2Σ-(v‧ = 1) ← X2 Π(v‧‧ = 0) bands of the OH and OD radicals generated in a plasma-discharge source using synchrotron radiation as a background continuum coupled with the VUV Fourier-transform spectrometer on the DESIRS beamline of synchrotron SOLEIL. High-resolution spectra permitted the quantification of transition frequencies, relative f-values, and natural line broadening. The f-values were absolutely calibrated with respect to a previous measurement of A2Σ+(v‧ = 0) ← X2 Π(v‧‧ = 0) (Wang et al., 1979). Lifetime broadening of the excited D2Σ-(v = 0) and D2Σ-(v = 1) levels is measured for the first time and compared with previous experimental limits, and implies a lifetime 5 times shorter than a theoretical prediction (van der Loo and Groenenboom, 2005). A local perturbation of the D2Σ-(v = 0) level in OH was found.
NASA Astrophysics Data System (ADS)
Chen, Mingji; Wang, Changxian; Cheng, Xiaodong; Gong, Congcheng; Song, Weili; Yuan, Xujin; Fang, Daining
2018-04-01
The realization of an ideal invisible cloak implementing transformation optics is still missing. An impedance matching concept is implanted into transformation optics cloak to generate an impedance matching cloak (IMC) shell. In this work, it is proved that impedance matching structure reduces the cloaking structure’s disturbance to a propagating electromagnetic field and improves its invisibility measured by scattering field intensity. Such a cylindrical IMC shell is designed, fabricated with proposed rounded rectangular split-ring-resonators (RR-SRRs), and experimental measurements show the total scattering field of a perfect electric conductor (PEC) cylinder surrounded by an IMC shell is improved greatly compared to the PEC cylinder showing electromagnetic wave front ripple suppression and a considerable scattering shrinking effect. IMC shell backward scattering field is suppressed down to 7.29%, compared to the previous value of 86.7% due to its impedance matching character, and overall scattering field intensity shrinking is down to 19.3% compared to the previously realized value of 56.4%. Sideward scattering field recorded in the experiment also has a remarkable improvement compared to the PEC cylinder. The impedance matching concept might enlighten the realization of an ideal cloak and other novel electromagnetic cloaking and shielding structures.
Gas exchange rates measured using a dual-tracer (SF6 and3he) method in the coastal waters of Korea
NASA Astrophysics Data System (ADS)
Lee, Hyun-Woo; Lee, Kitack; Kaown, Duk-In
2008-03-01
Over a period of 5 days between August 12 and 17, 2005, we performed a gas exchange experiment using the dual tracer method in a tidal coastal ocean located off the southern coast of Korea. The gas exchange rate was determined from temporal changes in the ratio of3He to SF6 measured daily in the surface mixed layer. The measured gas exchange rate ( k CO 2), normalized to a Schmidt number of 600 for CO2 in fresh water at 20°C, was approximately 5.0 cm h-1 at a mean wind speed of 3.9 m s-1 during the study period. This value is significantly less than those obtained from floating chamber-based experiments performed previously in estuarine environments, but is similar in magnitude to values obtained using the dual tracer method in river and tidal coastal waters and values predicted on the basis of the relationship between the gas exchange rate and wind speed (Wanninkhof 1992), which is generally applicable to the open ocean. Our result is also consistent with the relationship of Raymond and Cole (2001), which was derived from experiments carried out in estuarine environments using222Rn and chlorofluorocarbons along with measurements undertaken in the Hudson River, Canada, using SF6 and3He. Our results indicate that tidal action in a microtidal region did not discernibly enhance the measured k CO 2 value.
NASA Astrophysics Data System (ADS)
Varvell, K.; Cooper-Sarkar, A. M.; Parker, M. A.; Sansum, R. A.; Aderholz, M.; Armenise, N.; Baton, J. P.; Bullock, F. W.; Berggren, M.; Bertrand, D.; Brisson, V.; Burkot, W.; Calcchio, M.; Claytoh, E. F.; Coghen, T.; Erriquez, O.; Fitch, P. J.; Gerbier, G.; Guy, J.; Hulth, P. O.; Iaselli, G.; Jones, G. T.; Kasper, P.; Klein, H.; Kochowski, C.; Marage, P.; Mermikides, M.; Middleton, R. P.; Morrison, D. R. O.; Mobayyen, M. M.; Natali, S.; Neveu, M.; Nuzzo, S.; O'Neale, S. W.; Petiau, P.; Petrides, A.; Ruggieri, F.; Sacton, J.; Simopoulou, E.; Vallee, C.; Vayaki, A.; Venus, W. A.; Wachsmuth, H.; Wells, J.; Wittek, W.
1987-03-01
The isoscalar nucleon structure functions F 2( x, Q 2) and xF 3( x, Q 2) are measured in the range 0< Q 2<64 GeV2, 1.7< W 2<250 GeV2, x<0.7 using ν andbar v interactions on neon in BEBC. The data are used to evaluate possible higher twist contributions and to determine their impact on the evaluation of the QCD parameter Λ. In contrast to previous analyses reaching to such low W 2 values, it is found that a lowΛ _{overline {MS} } value in the neighbourhood of 100 MeV describes the data adequately and that the contribution of dynamical higher twist effects is small and negative.
High-Precision Half-Life Measurement for the Superallowed β+ Emitter Alm26
NASA Astrophysics Data System (ADS)
Finlay, P.; Ettenauer, S.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.
2011-01-01
A high-precision half-life measurement for the superallowed β+ emitter Alm26 was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1/2=6346.54±0.46stat±0.60systms, consistent with, but 2.5 times more precise than, the previous world average. The Alm26 half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed β decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for Alm26, 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi β-decay studies used to test the conserved vector current hypothesis and determine the Vud element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cassata, W. S.; Velsko, C. A.; Stoeffl, W.
We determined fission yields of xenon ( 133mXe, 135Xe, 135mXe, 137Xe, 138Xe, and 139Xe) resulting from 14 MeV neutron induced fission of depleted uranium at the National Ignition Facility. Measurements begin approximately 20 s after shot time, and yields have been determined for nuclides with half-lives as short as tens of seconds. We determined the relative independent yields of 133mXe, 135Xe, and 135mXe to significantly higher precision than previously reported. The relative fission yields of all nuclides are statistically indistinguishable from values reported by England and Rider (ENDF-349. LA-UR-94-3106, 1994), with exception of the cumulative yield of 139Xe. Furthermore, considerablemore » differences exist between our measured yields and the JEFF-3.1 database values.« less
An inventory of undiscovered Canadian mineral resources
NASA Technical Reports Server (NTRS)
Labovitz, M. L.; Griffiths, J. C.
1982-01-01
Unit regional value (URV) and unit regional weight are area standardized measures of the expected value and quantity, respectively, of the mineral resources of a region. Estimation and manipulation of the URV statistic is the basis of an approach to mineral resource evaluation. Estimates of the kind and value of exploitable mineral resources yet to be discovered in the provinces of Canada are used as an illustration of the procedure. The URV statistic is set within a previously developed model wherein geology, as measured by point counting geologic maps, is related to the historical record of mineral resource production of well-developed regions of the world, such as the 50 states of the U.S.A.; these may be considered the training set. The Canadian provinces are related to this training set using geological information obtained in the same way from geologic maps of the provinces. The desired predictions of yet to be discovered mineral resources in the Canadian provinces arise as a consequence. The implicit assumption is that regions of similar geology, if equally well developed, will produce similar weights and values of mineral resources.
NASA Astrophysics Data System (ADS)
Machicoane, Nathanaël; López-Caballero, Miguel; Bourgoin, Mickael; Aliseda, Alberto; Volk, Romain
2017-10-01
We present a method to improve the accuracy of velocity measurements for fluid flow or particles immersed in it, based on a multi-time-step approach that allows for cancellation of noise in the velocity measurements. Improved velocity statistics, a critical element in turbulent flow measurements, can be computed from the combination of the velocity moments computed using standard particle tracking velocimetry (PTV) or particle image velocimetry (PIV) techniques for data sets that have been collected over different values of time intervals between images. This method produces Eulerian velocity fields and Lagrangian velocity statistics with much lower noise levels compared to standard PIV or PTV measurements, without the need of filtering and/or windowing. Particle displacement between two frames is computed for multiple different time-step values between frames in a canonical experiment of homogeneous isotropic turbulence. The second order velocity structure function of the flow is computed with the new method and compared to results from traditional measurement techniques in the literature. Increased accuracy is also demonstrated by comparing the dissipation rate of turbulent kinetic energy measured from this function against previously validated measurements.
Sanz-Peláez, O; Angel-Moreno, A; Tapia-Martín, M; Conde-Martel, A; Carranza-Rodríguez, C; Carballo-Rastrilla, S; Soria-López, A; Pérez-Arellano, J L
2008-09-01
The progressive increase in the number of immigrants to Spain in recent years has made it necessary for health-care professionals to be aware about the specific characteristics of this population. An attempt is made in this study to define the normal range of common laboratory values in healthy sub-Saharan adults. Common laboratory values were studied (blood cell counts, clotting tests and blood biochemistry values) and were measured in 150 sub-Saharan immigrants previously defined as healthy according to a complete health evaluation that included a clinical history, physical examination, serologic tests and study of stool parasites. These results were compared to those from a control group consisting of 81 age-and-sex matched healthy blood donors taken from the Spanish native population. Statistically significant differences were obtained in the following values. Mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocytes, and serum levels of creatinine, uric acid, total protein content, creatin-kinase (CK), aspartate aminotransferase (AST), gamma-glutamyl-transpeptidase (GGT), Immunoglobulin G (IgG) and M (IgM). If evaluated according to the normal values in native people, a considerable percentage of healthy sub-Saharan immigrants would present
Hurter, K; Spreng, D; Rytz, U; Schawalder, P; Ott-Knüsel, F; Schmökel, H
2005-03-01
Diagnosis of osteoarthritis (OA) is based upon the clinical orthopaedic examination and the radiographic assessment, both of which can be non-specific and insensitive in early joint disease. The aim of our study was to investigate if there is an increase in serum levels of C-reactive protein (CRP) in degenerative joint disease (DJD) and if CRP could be used to help diagnose OA. We also wished to investigate whether it was possible to distinguish a joint with clinically and radiographically confirmed OA from a healthy joint by comparing lactate dehydrogenase (LDH) levels within the synovial fluid and the serum. We have shown a difference in synovial LDH levels between diseased and healthy joints (P<0.0001). There was also a significant difference between LDH in arthritic synovial fluid and serum, with no correlation between the values. Despite the fact that the values of our clinical patients tended to be higher than the values of our control group (P=0.05) all measured values were within the normal limits of previous publications. From these data, we conclude that single measurements of serum CRP do not permit detection of OA in clinical patients and that serum LDH is not a reliable marker for osteoarthritis. LDH levels in the synovial fluid could be of diagnostic value for identifying osteoarthritis.
Analysis of the 2H-evaporator scale samples (HTF-17-56, -57)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.; Coleman, C.; Diprete, D.
Savannah River National Laboratory analyzed scale samples from both the wall and cone sections of the 242-16H Evaporator prior to chemical cleaning. The samples were analyzed for uranium and plutonium isotopes required for a Nuclear Criticality Safety Assessment of the scale removal process. The analysis of the scale samples found the material to contain crystalline nitrated cancrinite and clarkeite. Samples from both the wall and cone contain depleted uranium. Uranium concentrations of 16.8 wt% 4.76 wt% were measured in the wall and cone samples, respectively. The ratio of plutonium isotopes in both samples is ~85% Pu-239 and ~15% Pu-238 bymore » mass and shows approximately the same 3.5 times higher concentration in the wall sample versus the cone sample as observed in the uranium concentrations. The mercury concentrations measured in the scale samples were higher than previously reported values. The wall sample contains 19.4 wt% mercury and the cone scale sample 11.4 wt% mercury. The results from the current scales samples show reasonable agreement with previous 242-16H Evaporator scale sample analysis; however, the uranium concentration in the current wall sample is substantially higher than previous measurements.« less
Compendium of Experimental Cetane Numbers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yanowitz, J.; Ratcliff, M. A.; McCormick, R. L.
This report is an updated version of the 2004 Compendium of Experimental Cetane Number Data and presents a compilation of measured cetane numbers for pure chemical compounds. It includes all available single compound cetane number data found in the scientific literature up until March 2014 as well as a number of unpublished values, most measured over the past decade at the National Renewable Energy Laboratory. This Compendium contains cetane values for 389 pure compounds, including 189 hydrocarbons and 201 oxygenates. More than 250 individual measurements are new to this version of the Compendium. For many compounds, numerous measurements are included,more » often collected by different researchers using different methods. Cetane number is a relative ranking of a fuel's autoignition characteristics for use in compression ignition engines; it is based on the amount of time between fuel injection and ignition, also known as ignition delay. The cetane number is typically measured either in a single-cylinder engine or a constant volume combustion chamber. Values in the previous Compendium derived from octane numbers have been removed, and replaced with a brief analysis of the correlation between cetane numbers and octane numbers. The discussion on the accuracy and precision of the most commonly used methods for measuring cetane has been expanded and the data has been annotated extensively to provide additional information that will help the reader judge the relative reliability of individual results.« less
Buonaccorsi, John P; Dalen, Ingvild; Laake, Petter; Hjartåker, Anette; Engeset, Dagrun; Thoresen, Magne
2015-04-15
Measurement error occurs when we observe error-prone surrogates, rather than true values. It is common in observational studies and especially so in epidemiology, in nutritional epidemiology in particular. Correcting for measurement error has become common, and regression calibration is the most popular way to account for measurement error in continuous covariates. We consider its use in the context where there are validation data, which are used to calibrate the true values given the observed covariates. We allow for the case that the true value itself may not be observed in the validation data, but instead, a so-called reference measure is observed. The regression calibration method relies on certain assumptions.This paper examines possible biases in regression calibration estimators when some of these assumptions are violated. More specifically, we allow for the fact that (i) the reference measure may not necessarily be an 'alloyed gold standard' (i.e., unbiased) for the true value; (ii) there may be correlated random subject effects contributing to the surrogate and reference measures in the validation data; and (iii) the calibration model itself may not be the same in the validation study as in the main study; that is, it is not transportable. We expand on previous work to provide a general result, which characterizes potential bias in the regression calibration estimators as a result of any combination of the violations aforementioned. We then illustrate some of the general results with data from the Norwegian Women and Cancer Study. Copyright © 2015 John Wiley & Sons, Ltd.
Development of unauthorized airborne emission source identification procedure
NASA Astrophysics Data System (ADS)
Shtripling, L. O.; Bazhenov, V. V.; Varakina, N. S.; Kupriyanova, N. P.
2018-01-01
The paper presents the procedure for searching sources of unauthorized airborne emissions. To make reasonable regulation decisions on airborne pollutant emissions and to ensure the environmental safety of population, the procedure provides for the determination of a pollutant mass emission value from the source being the cause of high pollution level and the search of a previously unrecognized contamination source in a specified area. To determine the true value of mass emission from the source, the minimum of the mean-root-square mismatch criterion between the computed and measured pollutant concentration in the given location is used.
Mass and Double-Beta-Decay Q Value of Xe136
NASA Astrophysics Data System (ADS)
Redshaw, Matthew; Wingfield, Elizabeth; McDaniel, Joseph; Myers, Edmund G.
2007-02-01
The atomic mass of Xe136 has been measured by comparing cyclotron frequencies of single ions in a Penning trap. The result, with 1 standard deviation uncertainty, is M(Xe136)=135.907 214 484 (11) u. Combined with previous results for the mass of Ba136 [Audi, Wapstra, and Thibault, Nucl. Phys. A 729, 337 (2003)NUPABL0375-947410.1016/j.nuclphysa.2003.11.003], this gives a Q value (M[Xe136]-M[Ba136])c2=2457.83(37)keV, sufficiently precise for ongoing searches for the neutrinoless double-beta decay of Xe136.
Mass and Double-Beta-Decay Q Value of {sup 136}Xe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Redshaw, Matthew; Wingfield, Elizabeth; McDaniel, Joseph
The atomic mass of {sup 136}Xe has been measured by comparing cyclotron frequencies of single ions in a Penning trap. The result, with 1 standard deviation uncertainty, is M({sup 136}Xe)=135.907 214 484 (11) u. Combined with previous results for the mass of {sup 136}Ba [Audi, Wapstra, and Thibault, Nucl. Phys. A 729, 337 (2003)], this gives a Q value (M[{sup 136}Xe]-M[{sup 136}Ba])c{sup 2}=2457.83(37) keV, sufficiently precise for ongoing searches for the neutrinoless double-beta decay of {sup 136}Xe.
Extended Le Chatelier's formula for carbon dioxide dilution effect on flammability limits.
Kondo, Shigeo; Takizawa, Kenji; Takahashi, Akifumi; Tokuhashi, Kazuaki
2006-11-02
Carbon dioxide dilution effect on the flammability limits was measured for various flammable gases. The obtained values were analyzed using the extended Le Chatelier's formula developed in a previous study. As a result, it has been found that the flammability limits of methane, propane, propylene, methyl formate, and 1,1-difluoroethane are adequately explained by the extended Le Chatelier's formula using a common set of parameter values. Ethylene, dimethyl ether, and ammonia behave differently from these compounds. The present result is very consistent with what was obtained in the case of nitrogen dilution.
Zero-crossing detector with sub-microsecond jitter and crosstalk
NASA Technical Reports Server (NTRS)
Dick, G. John; Kuhnle, Paul F.; Sydnor, Richard L.
1990-01-01
A zero-crossing detector (ZCD) was built and tested with a new circuit design which gives reduced time jitter compared to previous designs. With the new design, time jitter is reduced for the first time to a value which approaches that due to noise in the input amplifying stage. Additionally, with fiber-optic transmission of the output signal, crosstalk between units has been eliminated. The measured values are in good agreement with circuit noise calculations and approximately ten times lower than that for ZCD's presently installed in the JPL test facility. Crosstalk between adjacent units was reduced even more than the jitter.
Bredow, J; Oppermann, J; Scheyerer, M J; Gundlfinger, K; Neiss, W F; Budde, S; Floerkemeier, T; Eysel, P; Beyer, F
2015-05-01
Radiological study. To asses standard values, intra- and interobserver reliability and reproducibility of sacral slope (SS) and lumbar lordosis (LL) and the correlation of these parameters in patients with lumbar spinal stenosis (LSS). Anteroposterior and lateral X-rays of the lumbar spine of 102 patients with LSS were included in this retrospective, radiologic study. Measurements of SS and LL were carried out by five examiners. Intraobserver correlation and correlation between LL and SS were calculated with Pearson's r linear correlation coefficient and intraclass correlation coefficients (ICC) were calculated for inter- and intraobserver reliability. In addition, patients were examined in subgroups with respect to previous surgery and the current therapy. Lumbar lordosis averaged 45.6° (range 2.5°-74.9°; SD 14.2°), intraobserver correlation was between Pearson r = 0.93 and 0.98. The measurement of SS averaged 35.3° (range 13.8°-66.9°; SD 9.6°), intraobserver correlation was between Pearson r = 0.89 and 0.96. Intraobserver reliability ranged from 0.966 to 0.992 ICC in LL measurements and 0.944-0.983 ICC in SS measurements. There was an interobserver reliability ICC of 0.944 in LL and 0.990 in SS. Correlation between LL and SS averaged r = 0.79. No statistically significant differences were observed between the analyzed subgroups. Manual measurement of LL and SS in patients with LSS on lateral radiographs is easily performed with excellent intra- and interobserver reliability. Correlation between LL and SS is very high. Differences between patients with and without previous decompression were not statistically significant.
NASA Astrophysics Data System (ADS)
Reginald, Nelson; St. Cyr, Orville; Davila, Joseph; Rastaetter, Lutz; Török, Tibor
2018-05-01
Obtaining reliable measurements of plasma parameters in the Sun's corona remains an important challenge for solar physics. We previously presented a method for producing maps of electron temperature and speed of the solar corona using K-corona brightness measurements made through four color filters in visible light, which were tested for their accuracies using models of a structured, yet steady corona. In this article we test the same technique using a coronal model of the Bastille Day (14 July 2000) coronal mass ejection, which also contains quiet areas and streamers. We use the coronal electron density, temperature, and flow speed contained in the model to determine two K-coronal brightness ratios at (410.3, 390.0 nm) and (423.3, 398.7 nm) along more than 4000 lines of sight. Now assuming that for real observations, the only information we have for each line of sight are these two K-coronal brightness ratios, we use a spherically symmetric model of the corona that contains no structures to interpret these two ratios for electron temperature and speed. We then compare the interpreted (or measured) values for each line of sight with the true values from the model at the plane of the sky for that same line of sight to determine the magnitude of the errors. We show that the measured values closely match the true values in quiet areas. However, in locations of coronal structures, the measured values are predictably underestimated or overestimated compared to the true values, but can nevertheless be used to determine the positions of the structures with respect to the plane of the sky, in front or behind. Based on our results, we propose that future white-light coronagraphs be equipped to image the corona using four color filters in order to routinely create coronal maps of electron density, temperature, and flow speed.
Survey Geometry and the Internal Consistency of Recent Cosmic Shear Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Troxel, M.A.; et al.
We explore the impact of an update to the typical approximation for the shape noise term in the analytic covariance matrix for cosmic shear experiments that assumes the absence of survey boundary and mask effects. We present an exact expression for the number of galaxy pairs in this term based on the the survey mask, which leads to more than a factor of three increase in the shape noise on the largest measured scales for the Kilo-Degree Survey (KIDS-450) real-space cosmic shear data. We compare the result of this analytic expression to several alternative methods for measuring the shape noise from the data and find excellent agreement. This update to the covariance resolves any internal model tension evidenced by the previously large cosmological best-fitmore » $$\\chi^2$$ for the KiDS-450 cosmic shear data. The best-fit $$\\chi^2$$ is reduced from 161 to 121 for 118 degrees of freedom. We also apply a correction to how the multiplicative shear calibration uncertainty is included in the covariance. This change, along with a previously known update to the reported effective angular values of the data vector, jointly shift the inferred amplitude of the correlation function to higher values. We find that this improves agreement of the KiDS-450 cosmic shear results with Dark Energy Survey Year 1 and Planck results.« less
Magnetic properties of a new obsidian source, west Antelope Creek, Grant County, New Mexico
NASA Astrophysics Data System (ADS)
Sternberg, R. S.; Samuels, R.; Feinberg, J. M.; Shackley, M. S.
2013-12-01
This work is part of a Keck Geology Consortium project on characterizing obsidian sources in New Mexico using magnetic and geochemical properties. We collected over 3,000 samples, many of which were georeferenced, from 10 obsidian sources at three locales - Mule creek, Mt. Taylor, and Valles Caldera. One of the Mule Creek sources, herein called the west Antelope Creek (wAC) source, was previously unknown. The 143 samples collected at this source covered about 1 km2, but were not individually georeferenced. We plan to characterize the magnetic and chemical properties of this source to see if it is distinguishable from other nearby sources and useful for provenancing archaeological obsidians. Initial measurements on 34 specimens from 20 samples show NRM values range from 1-80 Am2/kg, and low-field susceptibilities range from 1.2-96 x 10-8 mass specific SI units. When there were two specimens from the same sample, results were in good agreement. The measurements define a rather broad field in NRM-susceptibility space compared to other Southwestern sources examined to date, and a considerably larger field than from the nearby Antelope Creek (AC) source. The previously measured NRM and susceptibility values from AC are all in the high end on both dimensions of the wAC field, so that these fields overlap but in many cases could be distinguished.
The reduction potential of nitric oxide (NO) and its importance to NO biochemistry
Bartberger, Michael D.; Liu, Wei; Ford, Eleonora; Miranda, Katrina M.; Switzer, Christopher; Fukuto, Jon M.; Farmer, Patrick J.; Wink, David A.; Houk, Kendall N.
2002-01-01
A potential of about −0.8 (±0.2) V (at 1 M versus normal hydrogen electrode) for the reduction of nitric oxide (NO) to its one-electron reduced species, nitroxyl anion (3NO−) has been determined by a combination of quantum mechanical calculations, cyclic voltammetry measurements, and chemical reduction experiments. This value is in accord with some, but not the most commonly accepted, previous electrochemical measurements involving NO. Reduction of NO to 1NO− is highly unfavorable, with a predicted reduction potential of about −1.7 (±0.2) V at 1 M versus normal hydrogen electrode. These results represent a substantial revision of the derived and widely cited values of +0.39 V and −0.35 V for the NO/3NO− and NO/1NO− couples, respectively, and provide support for previous measurements obtained by electrochemical and photoelectrochemical means. With such highly negative reduction potentials, NO is inert to reduction compared with physiological events that reduce molecular oxygen to superoxide. From these reduction potentials, the pKa of 3NO− has been reevaluated as 11.6 (±3.4). Thus, nitroxyl exists almost exclusively in its protonated form, HNO, under physiological conditions. The singlet state of nitroxyl anion, 1NO−, is physiologically inaccessible. The significance of these potentials to physiological and pathophysiological processes involving NO and O2 under reductive conditions is discussed. PMID:12177417
Tins, Bernhard; Cassar-Pullicino, Victor; Haddaway, Mike
2010-04-01
The exact pathomechanism of slipped upper femoral epiphysis (SUFE) remains elusive. This paper suggests a generalised abnormality of the development or maturation of cartilage as a possible cause. It is proposed that SUFE is part of a generalised abnormality of the cartilage formation or maturation resulting in abnormal measurements of cartilaginous joint structures. Radiographs of SUFE patients were assessed for the width of the unaffected hip joint and the symphysis pubis. Comparison with previously published normal values was made. Fifty-one patients were assessed, 35 male, 16 female. The average age was 12 years and 11 months combined for both sexes, 13 years 8 months for boys, 11 years 4 months for girls. Width of the symphysis pubis was assessed on 46 datasets, and comparison with normal values was performed using the Wilcoxon paired rank test. Statistical significance was set as p < 0.05. The average expected width was 5.8 mm (5.4-6.2 mm), the average measured width was 7.3 mm (3.5-12 mm), median value 7.0 mm, and the difference is statistically significant. Cartilage thickness of the uninvolved hip joint could be assessed in 46 cases, and comparison using the Wilcoxon paired rank test resulted in a statistically significant difference (significance set as p < 0.05). The average expected width was 4.9 mm (3.6-6.5 mm), the average measured width was 5.5 mm (4-8 mm), and median 5.3 mm. The results indicate that SUFE patients display a generalised increased width of joint cartilage for their age. This could be due to increased cartilage formation or decreased maturation or a combination of the two, and could explain the increased mechanical vulnerability of these children to normal or abnormal stresses, despite histologically normal organisation of the physis as shown in previous studies.
Dranitsaris, G; Leung, P; Ciotti, R; Ortega, A; Spinthouri, M; Liaropoulos, L; Labianca, R; Quadri, A
2001-01-01
The neurokinin-1 (NK1) receptor antagonists are a new class of agents designed to reduce the risk of emesis following chemotherapy, particularly with cisplatin. Early data from double-blind randomised trials suggest that an orally administered NK1 antagonist can reduce the absolute risk of acute and delayed emesis following cisplatin by 20 and 30%, respectively. To measure the value that patients with cancer place on improved emesis control and quality of life. Willingness-to-pay analysis. Five study sites in Canada, Italy, Spain and Greece. 245 patients with cancer either receiving chemotherapy with cisplatin or who had received cisplatin-based chemotherapy within the previous 6 months. After background information had been presented, patients were asked to define the maximum that they would pay per day for a drug that reduced their risk of acute and delayed (days 2 to 5) emesis by 20 and 30%, respectively. Costs were converted to US dollars ($US) using year 2000 exchange rates. For a 20% improvement in acute emesis, Canadian, Italian and Spanish patients with cancer were willing to pay $US46, $US34 and $US63 per day, respectively, compared with $US8 for patients from Greece (p < 0.001). For a 30% improvement in delayed emesis, Canadian, Italian and Spanish patients with cancer were also willing to pay more than their Greek counterparts (SUS41, $US31, $US50 and $US9 daily for 4 days, respectively; p < 0.001). These significant differences in patient value between countries remained, even after adjusting for socioeconomic variables and previous history of emesis. There are substantial cultural differences in how patients with cancer value benefit and improved quality of life. Since the majority of the world's population resides outside North America and Western Europe, there may be a need to re-evaluate perceived levels of patient benefit and measures of quality of life.
Yan, Shen-Qiang; Sun, Jian-Zhong; Yan, Yu-Qing; Wang, He; Lou, Min
2012-01-01
Background and Purpose Several magnetic resonance imaging (MRI) techniques are being exploited to measure brain iron levels increasingly as iron deposition has been implicated in some neurodegenerative diseases. However, there remains no unified evaluation of these methods as postmortem measurement isn't commonly available as the reference standard. The purpose of this study was to make a comparison among these methods and try to find a new index of brain iron. Methods We measured both phase values and R2* in twenty-four adults, and performed correlation analysis among the two methods and the previously published iron concentrations. We also proposed a new method using magnitude signal intensity and compared it with R2* and brain iron. Results We found phase value correlated with R2* in substantia nigra (r = −0.723, p<0.001) and putamen (r = −0.514, p = 0.010), while no correlations in red nucleus (r = −0.236, p = 0.268) and globus pallidus (r = −0.111, p = 0.605). And the new magnitude method had significant correlations in red nucleus (r = −0.593, p = 0.002), substantia nigra (r = −0.521, p = 0.009), globus pallidus (r = −0.750, p<0.001) and putamen (r = −0.547, p = 0.006) with R2*. A strong inverse correlation was also found between the new magnitude method and previously published iron concentrations in seven brain regions (r = −0.982, P<0.001). Conclusions Our study indicates that phase value may not be used for assessing the iron content in some brain regions especially globus pallidus. The new magnitude method is highly consistent with R2* especially in globus pallidus, and we assume that this approach may be acceptable as an index of iron content in iron-rich brain regions. PMID:22363719
Amaro, Mariana; Filipe, Hugo A L; Prates Ramalho, J P; Hof, Martin; Loura, Luís M S
2016-03-14
Nitrobenzoxadiazole (NBD)-labeled lipids are popular fluorescent membrane probes. However, the understanding of important aspects of the photophysics of NBD remains incomplete, including the observed shift in the emission spectrum of NBD-lipids to longer wavelengths following excitation at the red edge of the absorption spectrum (red-edge excitation shift or REES). REES of NBD-lipids in membrane environments has been previously interpreted as reflecting restricted mobility of solvent surrounding the fluorophore. However, this requires a large change in the dipole moment (Δμ) of NBD upon excitation. Previous calculations of the value of Δμ of NBD in the literature have been carried out using outdated semi-empirical methods, leading to conflicting values. Using up-to-date density functional theory methods, we recalculated the value of Δμ and verified that it is rather small (∼2 D). Fluorescence measurements confirmed that the value of REES is ∼16 nm for 1,2-dioleoyl-sn-glycero-3-phospho-l-serine-N-(NBD) (NBD-PS) in dioleoylphosphatidylcholine vesicles. However, the observed shift is independent of both the temperature and the presence of cholesterol and is therefore insensitive to the mobility and hydration of the membrane. Moreover, red-edge excitation leads to an increased contribution of the decay component with a shorter lifetime, whereas time-resolved emission spectra of NBD-PS displayed an atypical blue shift following excitation. This excludes restrictions to solvent relaxation as the cause of the measured REES and TRES of NBD, pointing instead to the heterogeneous transverse location of probes as the origin of these effects. The latter hypothesis was confirmed by molecular dynamics simulations, from which the calculated heterogeneity of the hydration and location of NBD correlated with the measured fluorescence lifetimes/REES. Globally, our combination of theoretical and experiment-based techniques has led to a considerably improved understanding of the photophysics of NBD and a reinterpretation of its REES in particular.
Reference value of impulse oscillometry in taiwanese preschool children.
Lai, Shen-Hao; Yao, Tsung-Chieh; Liao, Sui-Ling; Tsai, Ming-Han; Hua, Men-Chin; Yeh, Kuo-Wei; Huang, Jing-Long
2015-06-01
Impulse oscillometry is a potential technique for assessing the respiratory mechanism-which includes airway resistance and reactance during tidal breathing-in minimally cooperative young children. The reference values available in Asian preschool children are limited, especially in children of Chinese ethnicity. This study aimed to develop reference equations for lung function measurements using impulse oscillometry in Taiwanese children for future clinical application and research exploitation. Impulse oscillometry was performed in 150 healthy Taiwanese children (aged 2-6 years) to measure airway resistance and reactance at various frequencies. We used regression analysis to generate predictive equations separately by age, body height, body weight, and gender. The stepwise regression model revealed that body height was the most significant determinant of airway resistance and reactance in preschool young children. With the growth in height, a decrease in airway resistance and a paradoxical increase in reactance occurred at different frequencies. The regression curve of resistance at 5 Hz was comparable to previous reference values. This study provided reference values for several variables of the impulse oscillometry measurements in healthy Taiwanese children aged 2-6 years. With these reference data, clinical application of impulse oscillometry would be expedient in diagnosing respiratory diseases in preschool children. Copyright © 2014. Published by Elsevier B.V.
Dollar$ & $en$e. Part VI: Knowledge management: the state of the art.
Wilkinson, I
2001-01-01
In Part I of this series, I introduced the concept of memes (1). Memes are ideas or concepts--the information world equivalent of genes. The goal of this series of articles is to infect you with memes so you will assimilate, translate, and express them. No matter what our area of expertise or "-ology," we all are in the information business. Our goal is to be in the wisdom business. In the previous articles in this series, I showed that when we convert raw data into wisdom, we are moving along a value chain. Each step in the chain adds a different amount of value to the final product: timely, relevant, accurate, and precise knowledge that then can be applied to create the ultimate product in the value chain--wisdom. In part II of this series, I introduced a set of memes for measuring the cost of adding value (2). In part III of this series, I presented a new set of memes for measuring the added value of knowledge, i.e., intellectual capital (3). In part IV of this series, I discussed practical knowledge management tools for measuring the value of people, structural, and customer capital (4). In part V of this series, I applied intellectual capital and knowledge management concepts at the individual level, to help answer a fundamental question: what is my added value (5)? In the final part of this series, I will review the state of intellectual capital and knowledge management development to date and outline the direction of current knowledge management initiatives and research projects.
Rhee, Yun-Seok; Park, Chun-Woong; Shin, Yoon-Sub; Kam, Sung-Hoon; Lee, Kyu-Hyun; Park, Eun-Seok
2008-02-28
The aims of this study were to fast screen the compatibility of rabeprazole and excipients using a spectrocolorimeter and to examine the relationship between the color change value and drug contents/drug degradation products in solid dosage forms. The color change values of rabeprazole-excipient mixtures were measured using a spectrocolorimeter, with six tablet formulations compressed using a single-punch instrumental tablet press. The rabeprazole and degradation products contents in the tablets were analyzed using an HPLC method, with the color change values of the tablets measured using spectrocolorimetery for 4 weeks. These experiments indicated that the instrumental evaluation of color was a speedy, simple and useful tool in the determination of the interaction between the drug and excipients, as well as in the formulation of solid dosage forms. The relationships of the % reduced drug contents versus the color change value, and those of the % drug degradation products versus the color change value were exponentially increased in formulations containing zinc stearate. On stress testing, the color change value of rabeprazole was inconsistent with previous reports, as the degradation of rabeprazole can be greatly influenced by humidity as well as temperature. Consequently, these results highlight the potential of color formation in the application of pre-formulation and formulation of drugs.
NASA Astrophysics Data System (ADS)
Canagaratna, M. R.; Jimenez, J. L.; Kroll, J. H.; Chen, Q.; Kessler, S. H.; Massoli, P.; Hildebrandt Ruiz, L.; Fortner, E.; Williams, L. R.; Wilson, K. R.; Surratt, J. D.; Donahue, N. M.; Jayne, J. T.; Worsnop, D. R.
2015-01-01
Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state (OS C) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H2O+ and CO+ ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H2O+, CO+, and CO2+ fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO+ and especially H2O+ produced from many oxidized species. Combined AMS-vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.
Reliability and validity of quantifying absolute muscle hardness using ultrasound elastography.
Chino, Kentaro; Akagi, Ryota; Dohi, Michiko; Fukashiro, Senshi; Takahashi, Hideyuki
2012-01-01
Muscle hardness is a mechanical property that represents transverse muscle stiffness. A quantitative method that uses ultrasound elastography for quantifying absolute human muscle hardness has been previously devised; however, its reliability and validity have not been completely verified. This study aimed to verify the reliability and validity of this quantitative method. The Young's moduli of seven tissue-mimicking materials (in vitro; Young's modulus range, 20-80 kPa; increments of 10 kPa) and the human medial gastrocnemius muscle (in vivo) were quantified using ultrasound elastography. On the basis of the strain/Young's modulus ratio of two reference materials, one hard and one soft (Young's moduli of 7 and 30 kPa, respectively), the Young's moduli of the tissue-mimicking materials and medial gastrocnemius muscle were calculated. The intra- and inter-investigator reliability of the method was confirmed on the basis of acceptably low coefficient of variations (≤6.9%) and substantially high intraclass correlation coefficients (≥0.77) obtained from all measurements. The correlation coefficient between the Young's moduli of the tissue-mimicking materials obtained using a mechanical method and ultrasound elastography was 0.996, which was equivalent to values previously obtained using magnetic resonance elastography. The Young's moduli of the medial gastrocnemius muscle obtained using ultrasound elastography were within the range of values previously obtained using magnetic resonance elastography. The reliability and validity of the quantitative method for measuring absolute muscle hardness using ultrasound elastography were thus verified.
Reliability and Validity of Quantifying Absolute Muscle Hardness Using Ultrasound Elastography
Chino, Kentaro; Akagi, Ryota; Dohi, Michiko; Fukashiro, Senshi; Takahashi, Hideyuki
2012-01-01
Muscle hardness is a mechanical property that represents transverse muscle stiffness. A quantitative method that uses ultrasound elastography for quantifying absolute human muscle hardness has been previously devised; however, its reliability and validity have not been completely verified. This study aimed to verify the reliability and validity of this quantitative method. The Young’s moduli of seven tissue-mimicking materials (in vitro; Young’s modulus range, 20–80 kPa; increments of 10 kPa) and the human medial gastrocnemius muscle (in vivo) were quantified using ultrasound elastography. On the basis of the strain/Young’s modulus ratio of two reference materials, one hard and one soft (Young’s moduli of 7 and 30 kPa, respectively), the Young’s moduli of the tissue-mimicking materials and medial gastrocnemius muscle were calculated. The intra- and inter-investigator reliability of the method was confirmed on the basis of acceptably low coefficient of variations (≤6.9%) and substantially high intraclass correlation coefficients (≥0.77) obtained from all measurements. The correlation coefficient between the Young’s moduli of the tissue-mimicking materials obtained using a mechanical method and ultrasound elastography was 0.996, which was equivalent to values previously obtained using magnetic resonance elastography. The Young’s moduli of the medial gastrocnemius muscle obtained using ultrasound elastography were within the range of values previously obtained using magnetic resonance elastography. The reliability and validity of the quantitative method for measuring absolute muscle hardness using ultrasound elastography were thus verified. PMID:23029231
The brightness temperature of Venus and the absolute flux-density scale at 608 MHz.
NASA Technical Reports Server (NTRS)
Muhleman, D. O.; Berge, G. L.; Orton, G. S.
1973-01-01
The disk temperature of Venus was measured at 608 MHz near the inferior conjunction of 1972, and a value of 498 plus or minus 33 K was obtained using a nominal CKL flux-density scale. The result is consistent with earlier measurements, but has a much smaller uncertainty. Our theoretical model prediction is larger by a factor of 1.21 plus or minus 0.09. This discrepancy has been noticed previously for frequencies below 1400 MHz, but was generally disregarded because of the large observational uncertainties. No way could be found to change the model to produce agreement without causing a conflict with well-established properties of Venus. Thus it is suggested that the flux-density scale may require an upward revision, at least near this frequency, in excess of what has previously been considered likely.
Tappert, Mary M.; Porterfield, J. Zachary; Mehta-D'Souza, Padmaja; Gulati, Shelly
2013-01-01
The human parainfluenza virus (hPIV) hemagglutinin-neuraminidase (HN) protein binds (H) oligosaccharide receptors that contain N-acetylneuraminic acid (Neu5Ac) and cleaves (N) Neu5Ac from these oligosaccharides. In order to determine if one of HN′s two functions is predominant, we measured the affinity of H for its ligands by a solid-phase binding assay with two glycoprotein substrates and by surface plasmon resonance with three monovalent glycans. We compared the dissociation constant (Kd) values from these experiments with previously determined Michaelis-Menten constants (Kms) for the enzyme activity. We found that glycoprotein substrates and monovalent glycans containing Neu5Acα2-3Galβ1-4GlcNAc bind HN with Kd values in the 10 to 100 μM range. Km values for HN were previously determined to be on the order of 1 mM (M. M. Tappert, D. F. Smith, and G. M. Air, J. Virol. 85:12146–12159, 2011). A Km value greater than the Kd value indicates that cleavage occurs faster than the dissociation of binding and will dominate under N-permissive conditions. We propose, therefore, that HN is a neuraminidase that can hold its substrate long enough to act as a binding protein. The N activity can therefore regulate binding by reducing virus-receptor interactions when the concentration of receptor is high. PMID:23740997
An Integrated Finite Element-based Simulation Framework: From Hole Piercing to Hole Expansion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Xiaohua; Sun, Xin; Golovashchenko, Segey F.
An integrated finite element-based modeling framework is developed to predict the hole expansion ratio (HER) of AA6111-T4 sheet by considering the piercing-induced damages around the hole edge. Using damage models and parameters calibrated from previously reported tensile stretchability studies, the predicted HER correlates well with experimentally measured HER values for different hole piercing clearances. The hole piercing model shows burrs are not generated on the sheared surface for clearances less than 20%, which corresponds well with the experimental data on pierced holes cross-sections. Finite-element-calculated HER also is not especially sensitive to piercing clearances less than this value. However, as clearancesmore » increase to 30% and further to 40%, the HER values are predicted to be considerably smaller, also consistent with experimental measurements. Upon validation, the integrated modeling framework is used to examine the effects of different hole piercing and hole expansion conditions on the critical HERs for AA6111-T4.« less
Summary of studies on the blue-green autofluorescence and light transmission of the ocular lens
NASA Astrophysics Data System (ADS)
Van Best, Jaap A.; Kuppens, Esmeralda V.
1996-07-01
This paper reviews previous work done to demonstrate the clinical relevance of the measurement of blue-green autofluorescence and light transmission of the ocular lens. These can be determined quantitatively with fluorophotometry in a few seconds. Autofluorescence and transmission values are determined in healthy volunteers, in patients with insulin-dependent diabetes mellitus, and in patients with untreated glaucoma or untreated ocular hypertension. The lens autofluorescence of healthy volunteers increased linearly and transmission decreased exponentially with age. Each year of diabetes induced an increase of autofluorescence equal to one extra year of age. Untreated glaucoma or ocular hypertension had no significant effect on lens autofluorescence and transmission. Increased autofluorescence and decreased transmission values in comparison with values of a healthy population are proved to be indicative for an increased risk of developing cataract and the clinical usefulness of these measures is demonstrated. Diabetes is a risk factor for developing cataracts while untreated glaucoma or ocular hypertension is not.
NASA Technical Reports Server (NTRS)
Greenberg, Harry
1941-01-01
The pitching and the yawing moments of a vee-type and a conventional type of tail surface were measured. The tests were made in the presence of a fuselage and a wing-fuselage combination in such a way as to determine the moments contributed by the tail surfaces. The results showed that the vee-type tail tested, with a dihedral angle of 35.3 deg, was about 71 percent as effective in pitch as the conventional tail and had a yawing-moment to pitching-moment ratio of 0.3. The conventional tail, the panels of which were all congruent to those of the vee-type tail, had a yawing-moment to pitching-moment ratio of 0.48. These ratios are in fair agreement with values calculated by methods shown in this and previous reports. The values of the measured moments were reduced from 15 to 25 percent of the calculated value by fuselage interference.
NASA Astrophysics Data System (ADS)
Ferguson, Matthew Lee
A principal component in the protein coats of certain post-golgi and endocytic vesicles is clathrin, which appears as a three-legged heteropolymer (known as a triskelion) that assembles into polyhedral baskets principally made up of pentagonal and hexagonal faces. In vitro, this assembly depends on the pH, with baskets forming more readily at low pH and less readily at high pH. We have developed procedures, based on static and dynamic light scattering, to determine the radius of gyration, Rg, and hydrodynamic radius, RH, of isolated triskelia under conditions where basket assembly occurs. Calculations based on rigid molecular bead models of a triskelion show that the measured values can be accounted for by bending of the legs and a puckering at the vertex. We also show that the values of Rg and R H measured for clathrin triskelia in solution are qualitatively consistent with the conformation of an individual triskelion that is part of a "D6 barrel" basket assembly measured by cryo-EM tomography. We extended this study by performing small angle neutron scattering (SANS) experiments on isolated triskelia in solution under conditions where baskets do not assemble. SANS experiments were consistent with previous static light scattering experiments but showed a shoulder in the scattering function at intermediate q-values just beyond the central diffraction peak (the Guinier regime). Theoretical calculations based on rigid bead models of a triskelion showed well-defined features in this region different from the experiment. A flexible bead-spring model of a triskelion and Brownian dynamics simulations were used to generate a time averaged scattering function. This model adequately described the experimental data for flexibilities close to previous estimates from the analysis of electron micrographs.
Meyer, Matthew P; Klinman, Judith P
2011-01-26
This work describes the application of NMR to the measurement of secondary deuterium (2° (2)H) and carbon-13 ((13)C) kinetic isotope effects (KIEs) at positions 9-13 within the substrate linoleic acid (LA) of soybean lipoxygenase-1. The KIEs have been measured using LA labeled with either protium (11,11-h2-LA) or deuterium (11,11-d2-LA) at the reactive C11 position, which has been previously shown to yield a primary deuterium isotope effect of ca. 80. The conditions of measurement yield the intrinsic 2° (2)H and (13)C KIEs on k(cat)/K(m) directly for 11,11-d2-LA, whereas the values for the 2° (2)H KIEs for 11,11-h2-LA are obtained after correction for a kinetic commitment. The pattern of the resulting 2° (2)H and (13)C isotope effects reveals values that lie far above those predicted from changes in local force constants. Additionally, many of the experimental values cannot be modeled by electronic effects, torsional strain, or the simple inclusion of a tunneling correction to the rate. Although previous studies have shown the importance of extensive tunneling for cleavage of the primary hydrogen at C11 of LA, the present findings can only be interpreted by extending the conclusion of nonclassical behavior to the secondary hydrogens and carbons that flank the position undergoing C-H bond cleavage. A quantum mechanical method introduced by Buhks et al. [J. Phys. Chem. 1981, 85, 3763] to model the inner-sphere reorganization that accompanies electron transfer has been shown to be able to reproduce the scale of the 2° (2)H KIEs.
Testing the Late-Veneer hypothesis with selenium isotopes
NASA Astrophysics Data System (ADS)
Labidi, J.; Koenig, S.; Bennett, N.; Kurzawa, T.; Aierken, E.; Shahar, A.; Schoenberg, R.
2016-12-01
Selenium (Se) is a siderophile element displaying an excess abundance in Earth's mantle compared to experimental predictions [1], which may be attributed to the Late-Veneer. As Se is also volatile, testing the late-veneer addition of Se can constrain the origin of other volatile elements on Earth. Here we combine high-precision Se isotope measurements of metal-silicate partitioning experiments and chondrites to assess whether planetary differentiation could leave a measurable Se isotopic signature on planetary mantles. We performed Se isotopic measurements of 5 metal-silicate partitioning experiments and 20 chondrites of all major classes. Experiments were conducted at 1 GPa and 1650 C for 1 to 4 hours using the piston-cylinder apparatus at Carnegie's Geophysical Laboratory. After wet chemistry, data were obtained on a ThermoFisher Scientific™ NeptunePlus MC-ICP-MS at the University of Tübingen with a 74Se/77Se double spike technique. δ82/76Se values are given relative to NIST SRM-3149 and the external reproducibility calculated from duplicate meteorite analyses is ≤ 0.1‰ (2 s.d.). Chondrites vary over a 0.8‰ range of δ82/76Se values. CIs and CMs show evidence for heavier 82Se/76Se ratios, likely due to mixing processes in the proto-planetary nebula. When these isotopically heavier meteorites are excluded, remaining chondrites have δ82/76Se values varying over a 0.3‰ range, within uncertainty of previous results [2]. We suggest that these chondrites may be used to estimate a δ82/76Se value of bulk planets. At the conditions of our experiments, the partition coefficients for Se log Dmetal-silicate range from 0.7±0.1 to 1.9±0.1, consistent with previous work [1]. A small but resolvable Se isotopic fractionation was observed: 82Se/76Se ratios were enriched by ≤ 0.5‰ in the silicates relative to the metals. Thus, given current uncertainties for Se isotopic measurements, marginal differences between planetary mantles and chondrites may be resolved. [1] Rose-Weston et al. 2009, GCA, 73(15), 4598-4615. [2] Vollstaedt et al. 2016, 450, 372-380.
NASA Technical Reports Server (NTRS)
Dobson, Chris C.; Sung, C. C.
1998-01-01
Optical pumping of the ground states of sodium can radically alter the shape of the laser induced fluorescence excitation spectrum, complicating measurements of temperature, pressure, etc., which are based on these spectra. Modeling of the fluorescence using rate equations for the eight hyperfine states of the sodium D manifolds can be used to quantify the contribution to the ground state pumping of transitions among the hyperfine excited states induced by collisions with buffer gas atoms. This model is used here to determine, from the shape of experimental spectra, cross sections for (Delta)F transitions of the P(sub 3/2) state induced by collisions with helium and argon atoms, for a range of values assumed for the P(sub 1/2), (Delta)F cross sections. The hyperfine cross sections measured using this method, which is thought to be novel, are compared with cross sections for transitions involving polarized magnetic substates, m(sub F), measured previously using polarization sensitive absorption. Also, fine structure transition ((Delta)J) cross sections were measured in the pumped vapor, giving agreement with previous measurements made in the absence of pumping.
NASA Technical Reports Server (NTRS)
Dobson, Chris C.; Sung, C. C.
1999-01-01
Optical pumping of the ground states of sodium can radically alter the shape of the laser-induced fluorescence excitation spectrum, complicating measurements of temperature, pressure, etc., which are based on these spectra. Modeling of the fluorescence using rate equations for the eight hyperfine states of the sodium D manifolds can be used to quantify the contribution to the ground state pumping of transitions among the hyperfine excited states induced by collisions with buffer gas atoms. This model is used here to determine, from the shape of experimental spectra, cross sections lor DELTA.F transitions of the P(sub 3/2) state induced by collisions with helium and argon atoms, for a range of values assumed for the P(sub 1/2), DELTA.F cross sections. The hyperfine cross sections measured using this method, which to our knowledge is novel, are compared with cross sections for transitions involving polarized magnetic substates m(sub F) measured previously using polarization sensitive absorption. Also, fine-structure transition cross sections were measured in the pumped vapor, giving agreement with previous measurements made in the absence of pumping.
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, W.T. III
1985-11-04
We have studied two-photon absorption in solids theoretically and experimentally. We have shown that it is possible to use accurate band structure techniques to compute two-photon absorption spectra within 15% of measured values in a wide band-gap material, ZnS. The empirical pseudopotential technique that we used is significantly more accurate than previous models of two-photon absorption in zinc blende materials, including present tunneling theories (which are essentially parabolic-band results in disguise) and the nonparabolic-band formalism of Pidgeon et al. and Weiler. The agreement between our predictions and previous measurements allowed us to use ZnS as a reference material in ordermore » to validate a technique for measuring two-photon absorption that was previously untried in solids, pulsed dual-beam thermal lensing. With the validated technique, we examined nonlinear absorption in one other crystal (rutile) and in several glasses, including silicates, borosilicates, and one phosphate glass. Initially, we believed that the absorption edges of all the materials were comparable; however, subsequent evidence suggested that the effective band-gap energies of the glasses were above the energy of two photons in our measurement. Therefore, we attribute the nonlinear absorption that we observed in glasses to impurities or defects. The measured nonlinear absorption coefficients were of the order of a few cm/TW in the glasses and of the order of 10 cm/GW in the crystals, four orders of magnitude higher than in glasses. 292 refs.« less
IR spectra and properties of solid acetone, an interstellar and cometary molecule
NASA Astrophysics Data System (ADS)
Hudson, Reggie L.; Gerakines, Perry A.; Ferrante, Robert F.
2018-03-01
Mid-infrared spectra of amorphous and crystalline acetone are presented along with measurements of the refractive index and density for both forms of the compound. Infrared band strengths are reported for the first time for amorphous and crystalline acetone, along with IR optical constants. Vapor pressures and a sublimation enthalpy for crystalline acetone also are reported. Positions of 13C-labeled acetone are measured. Band strengths are compared to gas-phase values and to the results of a density-functional calculation. A 73% error in previous work is identified and corrected.
Many-Body Theory for Positronium-Atom Interactions
NASA Astrophysics Data System (ADS)
Green, D. G.; Swann, A. R.; Gribakin, G. F.
2018-05-01
A many-body-theory approach has been developed to study positronium-atom interactions. As first applications, we calculate the elastic scattering and momentum-transfer cross sections and the pickoff annihilation rate 1Zeff for Ps collisions with He and Ne. For He the cross section is in agreement with previous coupled-state calculations, while comparison with experiment for both atoms highlights discrepancies between various sets of measured data. In contrast, the calculated 1Zeff (0.13 and 0.26 for He and Ne, respectively) are in excellent agreement with the measured values.
Primary cosmic ray spectra in the range 20-60 GeV/n
NASA Technical Reports Server (NTRS)
Burnett, T. H.; Dake, S.; Derrickson, J. H.; Fuki, M.; Fountain, W. F.; Gregory, J. C.; Hayashi, T.; Hayashi, T.; Holynski, R.; Iwai, J.;
1985-01-01
Energy spectra for primary cosmic rays C-Fe above 20 GeV/n were measured on a balloon flight from Greenville S.C. in June 1982 with a hybrid electronic counter-emulsion chamber experiment. Fluxes above the atmosphere appear in general agreement with previously published values. The heavy events included in this data will be used along with the JACEE passive chamber data to provide a heavy composition direct measurement from 10 to the 12th power to approximately 10 to the 15th power eV total energy.
Determination of the STIS CCD Gain
NASA Astrophysics Data System (ADS)
Riley, Allyssa; Monroe, TalaWanda; Lockwood, Sean
2016-09-01
This report summarizes the analysis and absolute gain results of the STIS Cycle 23 special calibration program 14424 that was designed to measure the gain of amplifiers A, C and D at nominal gain settings of 1 and 4 e-/DN. We used the mean-variance technique and the results indicate a <3.5% change in the gain for amplifier D from when it was originally calculated pre-flight. We compared these values to previous measurements from Cycles 17 through 23. This report outlines the observations, methodology, and results of the mean-variance technique.
Carbon dioxide measurements in the stratosphere
NASA Technical Reports Server (NTRS)
Mauersberger, K.; Finstad, R.
1980-01-01
A mass spectrometer experiment for the analysis of minor constituents in the stratosphere has been flown successfully four times from Palestine, Texas on board a balloon gondola. The carbon dioxide mixing ratio, which shows unexpectedly large variations in the stratosphere, reached 400 ppm in one particular night flight. This is about 20% higher than the ground value. Evidence is presented that the experiment performed well during each of the balloon flights. The isotopic ratio C-12/C-13 was measured and found in good agreement with previous air analyses showing a depletion of C-13.
An improved method for LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; Wang, Qiaojie; He, Nannan; Ye, Yushan
2018-03-01
The colorimetric characterization of the display can achieve the purpose of precisely controlling the color of the monitor. This paper describes an improved method for estimating the gamma value of liquid-crystal displays (LCDs) without using a measurement device was described by Xiao et al. It relies on observer's luminance matching by presenting eight half-tone patterns with luminance from 1/9 to 8/9 of the maximum value of each color channel. Since the previous method lacked partial low frequency information, we partially replaced the half-tone patterns. A large number of experiments show that the color difference is reduced from 3.726 to 2.835, and our half-tone pattern can better estimate the visual gamma value of LCDs.
The Br+HO 2 reaction revisited: Absolute determination of the rate constant at 298 K
NASA Astrophysics Data System (ADS)
Laverdet, G.; Le Bras, G.; Mellouki, A.; Poulet, G.
1990-09-01
The absolute determination of the rate constant for the reaction Br+HO 2→HBr+O 2 has been done at 298 K using the discharge-flor EPR method. The value k1 = (1.5±0.2) × 10 -12 cm 3 molecule -1 s -1 was obtained. Previous indirect measurements of k1 from a discharge-flow, LIF/mass spectrometric study of the Br/H 2CO/O 2 system have been reinterpreted, leading to values for k1 ranging from 1.0 × 10 -12 to 2.2 × 10 -12 cm 3 molecule -1 s -1 at 298 K. These results are discussed and compared with other literature values.
Physiological Parameter Response to Variation of Mental Workload
Marinescu, Adrian Cornelius; Sharples, Sarah; Ritchie, Alastair Campbell; Sánchez López, Tomas; McDowell, Michael; Morvan, Hervé P.
2017-01-01
Objective: To examine the relationship between experienced mental workload and physiological response by noninvasive monitoring of physiological parameters. Background: Previous studies have examined how individual physiological measures respond to changes in mental demand and subjective reports of workload. This study explores the response of multiple physiological parameters and quantifies their added value when estimating the level of demand. Method: The study presented was conducted in laboratory conditions and required participants to perform a visual-motor task that imposed varying levels of demand. The data collected consisted of physiological measurements (heart interbeat intervals, breathing rate, pupil diameter, facial thermography), subjective ratings of workload (Instantaneous Self-Assessment Workload Scale [ISA] and NASA-Task Load Index), and the performance. Results: Facial thermography and pupil diameter were demonstrated to be good candidates for noninvasive workload measurements: For seven out of 10 participants, pupil diameter showed a strong correlation (R values between .61 and .79 at a significance value of .01) with mean ISA normalized values. Facial thermography measures added on average 47.7% to the amount of variability in task performance explained by a regression model. As with the ISA ratings, the relationship between the physiological measures and performance showed strong interparticipant differences, with some individuals demonstrating a much stronger relationship between workload and performance measures than others. Conclusion: The results presented in this paper demonstrate that physiological and pupil diameter can be used for noninvasive real-time measurement of workload. Application: The methods presented in this article, with current technological capabilities, are better suited for workplaces where the person is seated, offering the possibility of being applied to pilots and air traffic controllers. PMID:28965433
The influence of sulfur and hair growth on stable isotope diet estimates for grizzly bears.
Mowat, Garth; Curtis, P Jeff; Lafferty, Diana J R
2017-01-01
Stable isotope ratios of grizzly bear (Ursus arctos) guard hair collected from bears on the lower Stikine River, British Columbia (BC) were analyzed to: 1) test whether measuring δ34S values improved the precision of the salmon (Oncorhynchus spp.) diet fraction estimate relative to δ15N as is conventionally done, 2) investigate whether measuring δ34S values improves the separation of diet contributions of moose (Alces alces), marmot (Marmota caligata), and mountain goat (Oreamnos americanus) and, 3) examine the relationship between collection date and length of hair and stable isotope values. Variation in isotope signatures among hair samples from the same bear and year were not trivial. The addition of δ34S values to mixing models used to estimate diet fractions generated small improvement in the precision of salmon and terrestrial prey diet fractions. Although the δ34S value for salmon is precise and appears general among species and areas, sulfur ratios were strongly correlated with nitrogen ratios and therefore added little new information to the mixing model regarding the consumption of salmon. Mean δ34S values for the three terrestrial herbivores of interest were similar and imprecise, so these data also added little new information to the mixing model. The addition of sulfur data did confirm that at least some bears in this system ate marmots during summer and fall. We show that there are bears with short hair that assimilate >20% salmon in their diet and bears with longer hair that eat no salmon living within a few kilometers of one another in a coastal ecosystem. Grizzly bears are thought to re-grow hair between June and October however our analysis of sectioned hair suggested at least some hairs begin growing in July or August, not June and, that hair of wild bears may grow faster than observed in captive bears. Our hair samples may have been from the year of sampling or the previous year because samples were collected in summer when bears were growing new hair. The salmon diet fraction increased with later hair collection dates, as expected if samples were from the year of sampling because salmon began to arrive in mid-summer. Bears that ate salmon had shorter hair and δ15N and δ34S values declined with hair length, also suggesting some hair samples were grown the year of sampling. To be sure to capture an entire hair growth period, samples must be collected in late fall. Early spring samples are also likely to be from the previous year but the date when hair begins to grow appears to vary. Choosing the longest hair available should increase the chance the hair was grown during the previous year and, maximize the period for which diet is measured.
The influence of sulfur and hair growth on stable isotope diet estimates for grizzly bears
Curtis, P. Jeff; Lafferty, Diana J. R.
2017-01-01
Stable isotope ratios of grizzly bear (Ursus arctos) guard hair collected from bears on the lower Stikine River, British Columbia (BC) were analyzed to: 1) test whether measuring δ34S values improved the precision of the salmon (Oncorhynchus spp.) diet fraction estimate relative to δ15N as is conventionally done, 2) investigate whether measuring δ34S values improves the separation of diet contributions of moose (Alces alces), marmot (Marmota caligata), and mountain goat (Oreamnos americanus) and, 3) examine the relationship between collection date and length of hair and stable isotope values. Variation in isotope signatures among hair samples from the same bear and year were not trivial. The addition of δ34S values to mixing models used to estimate diet fractions generated small improvement in the precision of salmon and terrestrial prey diet fractions. Although the δ34S value for salmon is precise and appears general among species and areas, sulfur ratios were strongly correlated with nitrogen ratios and therefore added little new information to the mixing model regarding the consumption of salmon. Mean δ34S values for the three terrestrial herbivores of interest were similar and imprecise, so these data also added little new information to the mixing model. The addition of sulfur data did confirm that at least some bears in this system ate marmots during summer and fall. We show that there are bears with short hair that assimilate >20% salmon in their diet and bears with longer hair that eat no salmon living within a few kilometers of one another in a coastal ecosystem. Grizzly bears are thought to re-grow hair between June and October however our analysis of sectioned hair suggested at least some hairs begin growing in July or August, not June and, that hair of wild bears may grow faster than observed in captive bears. Our hair samples may have been from the year of sampling or the previous year because samples were collected in summer when bears were growing new hair. The salmon diet fraction increased with later hair collection dates, as expected if samples were from the year of sampling because salmon began to arrive in mid-summer. Bears that ate salmon had shorter hair and δ15N and δ34S values declined with hair length, also suggesting some hair samples were grown the year of sampling. To be sure to capture an entire hair growth period, samples must be collected in late fall. Early spring samples are also likely to be from the previous year but the date when hair begins to grow appears to vary. Choosing the longest hair available should increase the chance the hair was grown during the previous year and, maximize the period for which diet is measured. PMID:28248995
[Evaluation of serum PIVKA-II by Lumipulse PrestoII assay].
Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Kani, Satomi; Goto, Takaaki; Takasaka, Yoshimitsu; Matsuura, Kentaro; Sugauchi, Fuminaka; Moriyama, Kazushige; Murakami, Hiroshi; Kitajima, Sachiko; Mizokami, Masashi
2009-03-01
Measurements of serum concentrations of Des-gamma-carboxy Prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, in Lumipulsef assay, it was reported that antibodies against alkaline phosphatase (ALP) derived from anti bleeding sheets led false high values of PIVKA-II in the patients with HCC resection. To improve the previous issue, newly developed Lumipulse PrestoII assay was examined. (1) The assay was reliable and positively correlated with the previous assays (Lumipulse f and Picolumi, R = 0.997 and 0.994 (n=115), respectively). (2) Eleven cases, which had false high values of PIVKA-II by the Lumipulsef assay, were examined by the PrestoII assay with excess of inactive ALP. The false high values of 10 cases were improved, but only one was still high. False reactivity of this case was stronger than other cases, more effective adsorption was required. (3) Comparing the absorbent activity of inactive ALP among 6 different kinds, we found inactive ALP with much higher adsorbent activity. When this inactive ALP was applied to assay, false high values of PIVKA-II were improved in all 11 cases. In conclusion, the PrestoII assay, which applies the inactive ALP with high activity, is reliable and useful for clinical screening.
NASA Technical Reports Server (NTRS)
Sinyuk, Alexander; Torres, Omar; Dubovik, Oleg; Bhartia, P. K. (Technical Monitor)
2002-01-01
We present a method for retrieval of imaginary part of refractive index of desert dust aerosol in UV part of spectrum along with aerosol layer height above the ground. The method uses Total Ozone Mapping Spectrometer' (TOMS) measurements of the top of atmosphere radiances (331 nm, 360 nm) and aerosol optical depth provided by Aerosol Robotic Network (AERONET) (440 nm). Obtained values of imaginary part of refractive index retrieved for Saharan dust aerosol at 360 nm are significantly lower than previously reported values. The average retrieved values vary between 0.0054 and 0.0066 for different geographical locations. Our findings are in good agreement with the results of several recent investigations. The time variability of retrieved values for aerosol layer height is consistent with the predictions of dust transport model.
Cho, Hee Young; Hwang, Han Sung; Jung, Inkyung; Park, Yong Won; Kwon, Ja-Young; Kim, Young Han
2015-09-01
To evaluate the potential value of uterine artery Doppler velocimetry in diagnosing placenta accreta. Clinical records of all deliveries between April 1991 and March 2013 were retrospectively analyzed. Cases of intrauterine growth restriction, pregnancy-induced hypertension, multiple pregnancies, fetal anomalies, chromosomal abnormalities, and maternal medical illnesses such as cardiovascular disease, renal disease, and diabetes mellitus were excluded. A total of 11,210 cases were evaluated, including 403 cases of placenta previa without accreta (placenta previa) and 39 cases of placenta previa with accreta (placenta accreta). All patients underwent uterine artery Doppler velocimetry to measure the mean resistive index and pulsatility index (PI) in the third trimester. The analysis included participant characteristics such as age, parity, abortion history, previous cesarean delivery, gestational age at delivery, neonatal sex, and birth weight. The mean uterine artery PI was significantly lower in the placenta accreta group compared to previa alone (0.51 versus 0.57; P = .002). The odds ratios for placenta accreta were 2.4 for 2 or more previous abortions (P = .011) and 5.3 and 7.0 for 1 and 2 or more previous cesarean deliveries (P = .001 and .005). With an increase in the mean PI by 0.01, the odds ratio for placenta accreta decreased by 0.94 (P < .001). The area under the receive operating characteristic curve was 0.72 for previous cesarean delivery alone, increasing to 0.77 with the combination of the mean PI and previous cesarean delivery (P = .047). This study suggests that the mean PI measured by uterine artery Doppler velocimetry is reduced in patients with placenta accreta compared to those without accreta. The diagnostic accuracy of placenta accreta can be potentially improved if uterine artery Doppler values and the history of cesarean delivery are combined. © 2015 by the American Institute of Ultrasound in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodriguez, M., E-mail: manuel.rodriguez@rmp.uhn.ca; Rogers, D. W. O.
Purpose: To more accurately account for the relative intrinsic energy dependence and relative absorbed-dose energy dependence of TLDs when used to measure dose rate constants (DRCs) for {sup 125}I and {sup 103}Pd brachytherapy seeds, to thereby establish revised “measured values” for all seeds and compare the revised values with Monte Carlo and consensus values. Methods: The relative absorbed-dose energy dependence, f{sup rel}, for TLDs and the phantom correction, P{sub phant}, are calculated for {sup 125}I and {sup 103}Pd seeds using the EGSnrc BrachyDose and DOSXYZnrc codes. The original energy dependence and phantom corrections applied to DRC measurements are replaced bymore » calculated (f{sup rel}){sup −1} and P{sub phant} values for 24 different seed models. By comparing the modified measured DRCs to the MC values, an appropriate relative intrinsic energy dependence, k{sub bq}{sup rel}, is determined. The new P{sub phant} values and relative absorbed-dose sensitivities, S{sub AD}{sup rel}, calculated as the product of (f{sup rel}){sup −1} and (k{sub bq}{sup rel}){sup −1}, are used to individually revise the measured DRCs for comparison with Monte Carlo calculated values and TG-43U1 or TG-43U1S1 consensus values. Results: In general, f{sup rel} is sensitive to the energy spectra and models of the brachytherapy seeds. Values may vary up to 8.4% among {sup 125}I and {sup 103}Pd seed models and common TLD shapes. P{sub phant} values depend primarily on the isotope used. Deduced (k{sub bq}{sup rel}){sup −1} values are 1.074 ± 0.015 and 1.084 ± 0.026 for {sup 125}I and {sup 103}Pd seeds, respectively. For (1 mm){sup 3} chips, this implies an overall absorbed-dose sensitivity relative to {sup 60}Co or 6 MV calibrations of 1.51 ± 1% and 1.47 ± 2% for {sup 125}I and {sup 103}Pd seeds, respectively, as opposed to the widely used value of 1.41. Values of P{sub phant} calculated here have much lower statistical uncertainties than literature values, but systematic uncertainties from density and composition uncertainties are significant. Using these revised values with the literature’s DRC measurements, the average discrepancies between revised measured values and Monte Carlo values are 1.2% and 0.2% for {sup 125}I and {sup 103}Pd seeds, respectively, compared to average discrepancies for the original measured values of 4.8%. On average, the revised measured values are 4.3% and 5.9% lower than the original measured values for {sup 103}Pd and {sup 125}I seeds, respectively. The average of revised DRCs and Monte Carlo values is 3.8% and 2.8% lower for {sup 125}I and {sup 103}Pd seeds, respectively, than the consensus values in TG-43U1 or TG-43U1S1. Conclusions: This work shows that f{sup rel} is TLD shape and seed model dependent suggesting a need to update the generalized energy response dependence, i.e., relative absorbed-dose sensitivity, measured 25 years ago and applied often to DRC measurements of {sup 125}I and {sup 103}Pd brachytherapy seeds. The intrinsic energy dependence for LiF TLDs deduced here is consistent with previous dosimetry studies and emphasizes the need to revise the DRC consensus values reported by TG-43U1 or TG-43U1S1.« less
NASA Astrophysics Data System (ADS)
Hatch, Courtney D.; Greenaway, Ann L.; Christie, Matthew J.; Baltrusaitis, Jonas
2014-04-01
Fresh mineral aerosol has recently been found to be effective cloud condensation nuclei (CCN) and contribute to the number of cloud droplets in the atmosphere due to the effect of water adsorption on CCN activation. The work described here uses experimental water adsorption measurements on Na-montmorillonite and illite clay to determine empirical adsorption parameters that can be used in a recently derived theoretical framework (Frenkel-Halsey-Hill Activation Theory, FHH-AT) that accounts for the effect of water adsorption on CCN activation. Upon fitting the Frenkel-Halsey-Hill (FHH) adsorption model to water adsorption measurements, we find FHH adsorption parameters, AFHH and BFHH, to be 98 ± 22 and 1.79 ± 0.11 for montmorillonite and 75 ± 17 and 1.77 ± 0.11 for illite, respectively. The AFHH and BFHH values obtained from water adsorption measurements differ from values reported previously determined by applying FHH-AT to CCN activation measurements. Differences in FHH adsorption parameters were attributed to different methods used to obtain them and the hydratable nature of the clays. FHH adsorption parameters determined from water adsorption measurements were then used to calculate the critical super-saturation (sc) for CCN activation using FHH-AT. The relationship between sc and the dry particle diameter (Ddry) gave CCN activation curve exponents (xFHH) of -0.61 and -0.64 for montmorillonite and illite, respectively. The xFHH values were slightly lower than reported previously for mineral aerosol. The lower exponent suggests that the CCN activity of hydratable clays is less sensitive to changes in Ddry and the hygroscopicity parameter exhibits a broader variability with Ddry compared to more soluble aerosols. Despite the differences in AFHH, BFHH and xFHH, the FHH-AT derived CCN activities of montmorillonite and illite are quite similar to each other and in excellent agreement with experimental CCN measurements resulting from wet-generated clay aerosol. This study illustrates that FHH-AT using adsorption parameters constrained by water adsorption is a simple, valid method for predicting CCN activation of fresh clay minerals and provides parameters that can be used in atmospheric models to study the effect of mineral dust aerosol on cloud formation and climate.
Earth-atmosphere system and surface reflectivities in arid regions from Landsat MSS data
NASA Technical Reports Server (NTRS)
Otterman, J.; Fraser, R. S.
1976-01-01
Previously developed programs for computing atmospheric transmission and scattering of the solar radiation are used to compute the ratios of the earth-atmosphere system (space) directional reflectivities in the nadir direction to the surface Lambertian reflectivity, for the four bands of the Landsat multispectral scanner (MSS). These ratios are presented as graphs for two water vapor levels, as a function of the surface reflectivity, for various sun elevation angles. Space directional reflectivities in the vertical direction are reported for selected arid regions in Asia, Africa, and Central America from the spectral radiance levels measured by the Landsat MSS. From these space reflectivities, surface reflectivities are computed applying the pertinent graphs. These surface reflectivities are used to estimate the surface albedo for the entire solar spectrum. The estimated albedos are in the range 0.34-0.52, higher than the values reported by most previous researchers from space measurements, but are consistent with laboratory and in situ measurements.
Free-Space Quantum Signatures Using Heterodyne Measurements
NASA Astrophysics Data System (ADS)
Croal, Callum; Peuntinger, Christian; Heim, Bettina; Khan, Imran; Marquardt, Christoph; Leuchs, Gerd; Wallden, Petros; Andersson, Erika; Korolkova, Natalia
2016-09-01
Digital signatures guarantee the authorship of electronic communications. Currently used "classical" signature schemes rely on unproven computational assumptions for security, while quantum signatures rely only on the laws of quantum mechanics to sign a classical message. Previous quantum signature schemes have used unambiguous quantum measurements. Such measurements, however, sometimes give no result, reducing the efficiency of the protocol. Here, we instead use heterodyne detection, which always gives a result, although there is always some uncertainty. We experimentally demonstrate feasibility in a real environment by distributing signature states through a noisy 1.6 km free-space channel. Our results show that continuous-variable heterodyne detection improves the signature rate for this type of scheme and therefore represents an interesting direction in the search for practical quantum signature schemes. For transmission values ranging from 100% to 10%, but otherwise assuming an ideal implementation with no other imperfections, the signature length is shorter by a factor of 2 to 10. As compared with previous relevant experimental realizations, the signature length in this implementation is several orders of magnitude shorter.
Growing quality of life: urban trees, birth weight, and crime
John Kirkland; Geoffrey Donovan
2011-01-01
City dwellers can find many reasons to value neighborhood trees. The urban greenery provides relief from the built environment that many find appealing. In fact, a previous study found that a tree in front of a home increased that home's sales price by more than $7,000. Two new studies explore the measurable effects that urban trees and green spaces have a human...
NASA Astrophysics Data System (ADS)
Humphreys, Matthew P.; Greatrix, Florence M.; Tynan, Eithne; Achterberg, Eric P.; Griffiths, Alex M.; Fry, Claudia H.; Garley, Rebecca; McDonald, Alison; Boyce, Adrian J.
2016-06-01
The stable carbon isotope composition of dissolved inorganic carbon (δ13CDIC) in seawater was measured in samples collected during June-July 2014 in the subpolar North Atlantic. Sample collection was carried out on the RRS James Clark Ross cruise JR302, part of the "Radiatively Active Gases from the North Atlantic Region and Climate Change" (RAGNARoCC) research programme. The observed δ13CDIC values for cruise JR302 fall in a range from -0.07 to +1.95 ‰, relative to the Vienna Pee Dee Belemnite standard. From duplicate samples collected during the cruise, the 1σ precision for the 341 results is 0.08 ‰, which is similar to our previous work and other studies of this kind. We also performed a cross-over analysis using nearby historical δ13CDIC data, which indicated that there were no significant systematic offsets between our measurements and previously published results. We also included seawater reference material (RM) produced by A. G. Dickson (Scripps Institution of Oceanography, USA) in every batch of analysis, enabling us to improve upon the calibration and quality-control procedures from a previous study. The δ13CDIC is consistent within each RM batch, although its value is not certified. We report δ13CDIC values of 1.15 ± 0.03 ‰ and 1.27 ± 0.05 ‰ for batches 141 and 144 respectively. Our JR302 δ13CDIC data can be used - along with measurements of other biogeochemical variables - to constrain the processes that control DIC in the interior ocean, in particular the oceanic uptake of anthropogenic carbon dioxide and the biological carbon pump. Our δ13CDIC results are available from the British Oceanographic Data Centre - doi:10.5285/22235f1a-b7f3-687f-e053-6c86abc0c8a6.
Radon Outgassing in the Casa Diablo Region, Long Valley Caldera, California
NASA Astrophysics Data System (ADS)
Adarkwah, N.; Cuff, K.
2003-12-01
A radon outgassing survey has been conducted in the Casa Diablo region of the Long Valley Caldera. The Long Valley Caldera (LVC) is an active volcanic system situated along the eastern front of the Sierra Nevada mountain range in east-central California. The survey was centered in an area .4 km northwest of the Casa Diablo geothermal power plant, located along the southwestern-most rim of the caldera?s resurgent dome. Results from previous radon emission studies in LVC indicate that high degrees of outgassing occur in association with relatively narrow networks of unsealed fractures (Cuff, et al., 2000 and Hoyos, et al., 2001). These fracture networks act as pathways for radon and other gases generated at depth as they migrate toward the surface. The purpose of the present study was to determine whether or not a relationship exists between radon emissions in the current survey area and that in a previously surveyed area approximately .8 km west of the geothermal plant. To accomplish this, we measured radon concentration in soil-gas at 35 separate sites. These sites were located within a 140 by 100 meter grid, with 20 meter spacing between each sample site. A radon outgassing map was then created using measured concentration values along with longitude and latitude values for each sample location. Geologic maps of the area were also analyzed and compared with radon outgassing maps. Analysis of these maps indicates that radon outgassing occurs through a set of crisscrossing fractures, trending southwest-northeast and northwest-southeast respectively. The northwest trending fractures are related to mapped normal faults in the area, while those with a southwest-northeast orientation are associated with an unmapped zone of faulting that is roughly perpendicular to the other faults. The latter set of fractures has a trend similar to that discovered in the previously surveyed area to the west. In both areas the highest readings were in excess of three times background radon concentration values measured in the field, and were obtained at locations believed to be where two sets of fractures intersect.
Force Measurements of Single and Double Barrier DBD Plasma Actuators in Quiescent Air
NASA Technical Reports Server (NTRS)
Hoskinson, Alan R.; Hershkowitz, Noah; Ashpis, David E.
2008-01-01
We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators, as the electrode diameter decreased below those values previously studied the induced Force increases exponentially rather than linearly. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. In addition, we have shown the the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.
Kerr, Kathleen F; Bansal, Aasthaa; Pepe, Margaret S
2012-09-15
In this issue of the Journal, Pencina and et al. (Am J Epidemiol. 2012;176(6):492-494) examine the operating characteristics of measures of incremental value. Their goal is to provide benchmarks for the measures that can help identify the most promising markers among multiple candidates. They consider a setting in which new predictors are conditionally independent of established predictors. In the present article, the authors consider more general settings. Their results indicate that some of the conclusions made by Pencina et al. are limited to the specific scenarios the authors considered. For example, Pencina et al. observed that continuous net reclassification improvement was invariant to the strength of the baseline model, but the authors of the present study show this invariance does not hold generally. Further, they disagree with the suggestion that such invariance would be desirable for a measure of incremental value. They also do not see evidence to support the claim that the measures provide complementary information. In addition, they show that correlation with baseline predictors can lead to much bigger gains in performance than the conditional independence scenario studied by Pencina et al. Finally, the authors note that the motivation of providing benchmarks actually reinforces previous observations that the problem with these measures is they do not have useful clinical interpretations. If they did, researchers could use the measures directly and benchmarks would not be needed.
Shackelford, S D; Wheeler, T L; Koohmaraie, M
2012-03-01
The present experiment was conducted to provide a validation of a previously developed model for online classification of US Select carcasses for LM tenderness based on visible and near-infrared (VISNIR) spectroscopy and to determine if the accuracy of VISNIR-based tenderness classification could be enhanced by making measurements after postmortem aging. Spectroscopy was conducted online, during carcass grading, at a large-scale commercial fed beef-processing facility, and the strip loin was obtained from the left side of US Select carcasses (n = 467). Slice shear force (SSF) was measured on fresh steaks at 2 and 14 d postmortem. Online VISNIR tenderness classes differed in mean SSF values at both 2 d (29.4 vs. 33.6 kg) and 14 d (18.0 vs. 21.2 kg) postmortem (P < 10(-7)). Online VISNIR tenderness classes differed in both the percentage of carcasses with LM SSF values greater than 40 kg at 2 d postmortem (5.1 vs. 21.0%; P < 10(-6)) and the percentage of carcasses with LM SSF values greater than 25 kg at 14 d postmortem (6.8 vs. 23.2%; P < 10(-5)). Whereas 15.0% of the carcasses sampled for this experiment had LM SSF values greater than 25 kg at 14 d postmortem, only 6.8% of the carcasses classified as tender by VISNIR had LM SSF values greater than 25 kg. All the carcasses sampled that had LM SSF values greater than 35 kg at 14 d postmortem were accurately classified as tough by VISNIR. Before measurement of SSF on d 14, VISNIR spectroscopy was conducted on the SSF steak. Tenderness classes based on d 14 VISNIR spectra differed both in mean SSF value at 14 d postmortem (17.7 vs. 21.6 kg; P < 10(-11)) and the percentage of carcasses with LM SSF values greater than 25 kg at 14 d postmortem (7.3 vs. 22.7%; P < 10(-5)). These data support our previous work showing that VISNIR spectroscopy can be used to classify US Select carcasses noninvasively for LM tenderness, and the results establish that this technology could also be applied to aged US Select strip loins. This technology would allow packing companies and other segments of the beef marketing chain to identify US Select carcasses or strip loins that excel in LM tenderness for use in branded beef programs.
SCATTERING OF NEUTRONS BY $alpha$-PARTICLES AT 14.1 Mev
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fasoli, U.; Zago, G.
1963-12-01
The angular distribution of 14.1-Mev neutrons elastically scattered by alpha particles was measured by observing the alpha recoils in a helium-filled cloud chamber. The results are in satisfactory agreement with those previously obtained by others. Inspection of the small-angle region of the measured distribution shows that phase shifts of orbital angular momentum higher than L = 1 are not negligible, although, according to the present experiment, quantitative information on D-waves turns out to be somewhat elusive. The azimuthal angular distribution agrees well with the value P = 0.02 of the neutron beam polarization, as measured by Perkins. (auth)
Measurement of Charged Pions from Neutrino-produced Nuclear Resonance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simon, Clifford N.
2014-01-01
A method for identifying stopped pions in a high-resolution scintillator bar detector is presented. I apply my technique to measure the axial mass M Δ Afor production of the Δ(1232) resonance by neutrino, with the result M Δ A = 1.16±0.20 GeV (68% CL) (limited by statistics). The result is produced from the measured spectrum of reconstructed momentum-transfer Q 2. I proceed by varying the value of M Δ A in a Rein-Sehgal-based Monte Carlo to produce the best agreement, using shape only (not normalization). The consistency of this result with recent reanalyses of previous bubble-chamber experiments is discussed.
An evidential link prediction method and link predictability based on Shannon entropy
NASA Astrophysics Data System (ADS)
Yin, Likang; Zheng, Haoyang; Bian, Tian; Deng, Yong
2017-09-01
Predicting missing links is of both theoretical value and practical interest in network science. In this paper, we empirically investigate a new link prediction method base on similarity and compare nine well-known local similarity measures on nine real networks. Most of the previous studies focus on the accuracy, however, it is crucial to consider the link predictability as an initial property of networks itself. Hence, this paper has proposed a new link prediction approach called evidential measure (EM) based on Dempster-Shafer theory. Moreover, this paper proposed a new method to measure link predictability via local information and Shannon entropy.
NASA Astrophysics Data System (ADS)
Denton, R. E.; Wang, Y.; Webb, P. A.; Tengdin, P. M.; Goldstein, J.; Redfern, J. A.; Reinisch, B. W.
2012-03-01
Using measurements of the electron density ne found from passive radio wave observations by the IMAGE spacecraft RPI instrument on consecutive passes through the magnetosphere, we calculate the long-term (>1 day) refilling rate of equatorial electron density dne,eq/dt from L = 2 to 9. Our events did not exhibit saturation, probably because our data set did not include a deep solar minimum and because saturation is an unusual occurrence, especially outside of solar minimum. The median rate in cm-3/day can be modeled with log10(dne,eq/dt) = 2.22 - 0.006L - 0.0347L2, while the third quartile rate can be modeled with log10(dne,eq/dt) = 3.39 - 0.353L, and the mean rate can be modeled as log10(dne,eq/dt) = 2.74 - 0.269L. These statistical values are found from the ensemble of all observed rates at each L value, including negative rates (decreases in density due to azimuthal structure or radial motion or for other reasons), in order to characterize the typical behavior. The first quartile rates are usually negative for L < 4.7 and close to zero for larger L values. Our rates are roughly consistent with previous observations of ion refilling at geostationary orbit. Most previous studies of refilling found larger refilling rates, but many of these examined a single event which may have exhibited unusually rapid refilling. Comparing refilling rates at solar maximum to those at solar minimum, we found that the refilling rate is larger at solar maximum for small L < 4, about the same at solar maximum and solar minimum for L = 4.2 to 5.8, and is larger at solar minimum for large L > 5.8 such as at geostationary orbit (L ˜ 6.8) (at least to L of about 8). These results agree with previous results for ion refilling at geostationary orbit, may agree with previous results at lower L, and are consistent with some trends for ionospheric density.
NASA Astrophysics Data System (ADS)
Abbasi, R. U.; Abe, M.; Abu-Zayyad, T.; Allen, M.; Anderson, R.; Azuma, R.; Barcikowski, E.; Belz, J. W.; Bergman, D. R.; Blake, S. A.; Cady, R.; Chae, M. J.; Cheon, B. G.; Chiba, J.; Chikawa, M.; Cho, W. R.; Fujii, T.; Fukushima, M.; Goto, T.; Hanlon, W.; Hayashi, Y.; Hayashida, N.; Hibino, K.; Honda, K.; Ikeda, D.; Inoue, N.; Ishii, T.; Ishimori, R.; Ito, H.; Ivanov, D.; Jui, C. C. H.; Kadota, K.; Kakimoto, F.; Kalashev, O.; Kasahara, K.; Kawai, H.; Kawakami, S.; Kawana, S.; Kawata, K.; Kido, E.; Kim, H. B.; Kim, J. H.; Kim, J. H.; Kitamura, S.; Kitamura, Y.; Kuzmin, V.; Kwon, Y. J.; Lan, J.; Lim, S. I.; Lundquist, J. P.; Machida, K.; Martens, K.; Matsuda, T.; Matsuyama, T.; Matthews, J. N.; Minamino, M.; Mukai, Y.; Myers, I.; Nagasawa, K.; Nagataki, S.; Nakamura, T.; Nonaka, T.; Nozato, A.; Ogio, S.; Ogura, J.; Ohnishi, M.; Ohoka, H.; Oki, K.; Okuda, T.; Ono, M.; Oshima, A.; Ozawa, S.; Park, I. H.; Pshirkov, M. S.; Rodriguez, D. C.; Rubtsov, G.; Ryu, D.; Sagawa, H.; Sakurai, N.; Sampson, A. L.; Scott, L. M.; Shah, P. D.; Shibata, F.; Shibata, T.; Shimodaira, H.; Shin, B. K.; Shin, H. S.; Smith, J. D.; Sokolsky, P.; Springer, R. W.; Stokes, B. T.; Stratton, S. R.; Stroman, T.; Suzawa, T.; Takamura, M.; Takeda, M.; Takeishi, R.; Taketa, A.; Takita, M.; Tameda, Y.; Tanaka, H.; Tanaka, K.; Tanaka, M.; Thomas, S. B.; Thomson, G. B.; Tinyakov, P.; Tkachev, I.; Tokuno, H.; Tomida, T.; Troitsky, S.; Tsunesada, Y.; Tsutsumi, K.; Uchihori, Y.; Udo, S.; Urban, F.; Vasiloff, G.; Wong, T.; Yamane, R.; Yamaoka, H.; Yamazaki, K.; Yang, J.; Yashiro, K.; Yoneda, Y.; Yoshida, S.; Yoshii, H.; Zollinger, R.; Zundel, Z.
2015-04-01
Previous measurements of the composition of Ultra-High Energy Cosmic Rays (UHECRs) made by the High Resolution Fly's Eye (HiRes) and Pierre Auger Observatory (PAO) are seemingly contradictory, but utilize different detection methods, as HiRes was a stereo detector and PAO is a hybrid detector. The five year Telescope Array (TA) Middle Drum hybrid composition measurement is similar in some, but not all, respects in methodology to PAO, and good agreement is evident between data and a light, largely protonic, composition when comparing the measurements to predictions obtained with the QGSJetII-03 and QGSJet-01c models. These models are also in agreement with previous HiRes stereo measurements, confirming the equivalence of the stereo and hybrid methods. The data is incompatible with a pure iron composition, for all models examined, over the available range of energies. The elongation rate and mean values of Xmax are in good agreement with Pierre Auger Observatory data. This analysis is presented using two methods: data cuts using simple geometrical variables and a new pattern recognition technique.
Line Assignments and Position Measurements in Several Weak CO2 Bands between 4590 /cm and 7930/ cm
NASA Technical Reports Server (NTRS)
Giver, L. P.; Kshirsagar, R. J.; Freedman, R. C.; Chackerian, C.; Wattson, R. B.
1998-01-01
A substantial set of CO2 spectra from 4500 to 12000 /cm has been obtained at Ames with 1500 m path length using a Bomem DA8 FTS. The signal/noise was improved compared to prior spectra obtained in this laboratory by including a filter wheel limiting the band-pass of each spectrum to several hundred/cm. We have measured positions of lines in several weak bands not previously resolved in laboratory spectra. Using our positions and assignments of lines of the Q branch of the 31103-00001 vibrational band at 4591/cm, we have re-determined the rotational constants for the 31103f levels. Q-branch lines of this band were previously observed, but misassigned, in Venus spectra by Mandin. The current HITRAN values of the rotational constants for this level are incorrect due to the Q-branch misassignments. Our prior measurements of the 21122-00001 vibrational band at 7901/cm were limited to Q- and R-branch lines; with the improved signal/noise of these new spectra we have now measured lines in the weaker P branch.
The Importance of Pro-Environmental Behavior in Adolescent
NASA Astrophysics Data System (ADS)
Palupi, Tyas; Sawitri, Dian R.
2018-02-01
Studies regarding pro-environmental behavior in adolescents are lacking. This study aimed to examine the importance of pro-environmental behavior in adolescents (high school and university students) by conducting literature review from previous studies on pro environmental behavior. Pro-environmental behavior is the behavior of individuals that contributes towards environmental preservation. Based on previous studies, measurement of pro-environmental behavior were investigated on several theories, namely theory of planned behavior (TPB) and value, belief, norms (VBN) by using aspects of pro environmental behavior. Young people with critical thinking, and good environmental education, are expected to behave more environmentally friendly for creating a sustainable future.
The Consistency of Isotopologues of Ambient Atmospheric Nitric Acid in Passively Collected Samples
NASA Astrophysics Data System (ADS)
Bell, M. D.; Sickman, J. O.; Bytnerowicz, A.; Padgett, P.; Allen, E. B.
2012-12-01
Anthropogenic sources of nitrogen oxides have previously been shown to have distinctive isotopic signatures of oxygen and nitrogen. Nylon filters are currently used in passive sampling arrays to measure ambient atmospheric nitric acid concentrations and estimate deposition rates. This experiment measured the ability of nylon filters to consistently collect isotopologues of atmospheric nitric acid in the same ratios as they are present in the atmosphere. Samplers were deployed in continuous stirred tank reactors (CSTR) and at field sites across a nitrogen deposition gradient in Southern California. Filters were exposed over a four week period with individual filters being subjected to 1-4 week exposure times. Extracted nitric acid were measured for δ18O and δ15N ratios and compared for consistency based on length of exposure and amount of HNO3 collected. Filters within the CSTRs collected HNO3 at a consistent rate in both high and low concentration chambers. After two weeks of exposure, the mean δ18O values were within 0.5‰ of the δ18O of the source HNO3 solution. The mean of all weekly exposures were within 0.5‰ of the δ15N of the source solution, but after three weeks, the mean δ15N of adsorbed HNO3 was within 0.2‰. As the length of the exposure increased, the variability of measured delta values decreased for both elements. The field samplers collected HNO3 consistent with previously measured values along a deposition gradient. The mean δ18O at high deposition sites was 52.2‰ compared to 35.7‰ at the low deposition sites. Mean δ15N values were similar at all sites across the deposition gradient. Due to precipitation events occurring during the exposure period, the δ15N and δ18O of nitric acid were highly variable at all field sites. At single sites, changes in δ15N and δ18O were negatively correlated, consistent with two-sourcing mixing dynamics, but the slope of the regressions differed between high and low deposition sites. Anthropogenic sources of atmospheric nitric acid accounted for 58% of the atmospheric nitric acid at the high deposition sites and 36.5% of the atmospheric nitric acid at the low deposition sites. The nylon filters proved to be an effective means of collecting isotopologues of HNO3 consistent with atmospheric concentrations. A length of the exposure of two weeks stabilizes isotopologue composition and minimizes the chance of variable weather events altering atmospheric values.
Arcjet Flow Properties Determined from Laser-Induced Fluorescence of Atomic Species
NASA Technical Reports Server (NTRS)
Fletcher, Douglas G.
1997-01-01
Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D<-2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-Beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure shows relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. This poster represents an application of laser-spectroscopic measurements in an important test facility. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities.
Allakhverdiev, Suleyman I; Tsuchiya, Tohru; Watabe, Kazuyuki; Kojima, Akane; Los, Dmitry A; Tomo, Tatsuya; Klimov, Vyacheslav V; Mimuro, Mamoru
2011-05-10
In a previous study, we measured the redox potential of the primary electron acceptor pheophytin (Phe) a of photosystem (PS) II in the chlorophyll d-dominated cyanobacterium Acaryochloris marina and a chlorophyll a-containing cyanobacterium, Synechocystis. We obtained the midpoint redox potential (E(m)) values of -478 mV for A. marina and -536 mV for Synechocystis. In this study, we measured the redox potentials of the primary electron acceptor quinone molecule (Q(A)), i.e., E(m)(Q(A)/Q(A)(-)), of PS II and the energy difference between [P680·Phe a(-)·Q(A)] and [P680·Phe a·Q(A)(-)], i.e., ΔG(PhQ). The E(m)(Q(A)/Q(A)(-)) of A. marina was determined to be +64 mV without the Mn cluster and was estimated to be -66 to -86 mV with a Mn-depletion shift (130-150 mV), as observed with other organisms. The E(m)(Phe a/Phe a(-)) in Synechocystis was measured to be -525 mV with the Mn cluster, which is consistent with our previous report. The Mn-depleted downshift of the potential was measured to be approximately -77 mV in Synechocystis, and this value was applied to A. marina (-478 mV); the E(m)(Phe a/Phe a(-)) was estimated to be approximately -401 mV. These values gave rise to a ΔG(PhQ) of -325 mV for A. marina and -383 mV for Synechocystis. In the two cyanobacteria, the energetics in PS II were conserved, even though the potentials of Q(A)(-) and Phe a(-) were relatively shifted depending on the special pair, indicating a common strategy for electron transfer in oxygenic photosynthetic organisms.
Lifetimes of low-lying excited states in Kr 50 36 86
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henderson, J.; Chester, A.; Ball, G. C.
b>Bmore » The evolution of nuclear magic numbers at extremes of isospin is a topic at the forefront of contemporary nuclear physics. N = 50 is a prime example, with increasing experimental data coming to light on potentially doubly magic Sn 100 and Ni 78 at the proton-rich and proton-deficient extremes, respectively; however, experimental discrepancies exist in the data for less exotic systems. Purpose: In Kr 86 the B ( E 2 ; 2 1 + → 0 1 + ) value—a key indicator of shell evolution—has been experimentally determined by two different methodologies, with the results deviating by 3 σ . Here, we report on a new high-precision measurement of this value, as well as the first measured lifetimes and hence transition strengths for the 2 2 + and 3 ( 2 ) - states in the nucleus. Methods: The Doppler-shift attenuation method was implemented using the TRIUMF-ISAC γ -ray escape-suppressed spectrometer (TIGRESS) γ -ray spectrometer and the TIGRESS integrated plunger device. High-statistics Monte Carlo simulations were utilized to extract lifetimes in accordance with state-of-the-art methodologies. Results: Lifetimes of τ ( 2 1 + ) = 336 ± 4 (stat.) ± 20 (sys.) fs, τ ( 2 2 + ) = 263 ± 9 (stat.) ± 19 (sys.) fs, and τ ( 3 ( 2 ) - ) = 73 ± 6 (stat.) ± 32 (sys.) fs were extracted. This yields a transition strength for the first-excited state of B ( E 2 ; 2 1 + → 0 1 + ) = 259 ± 3 (stat.) ± 16 (sys.) e 2 fm 4 . Conclusions: Finally, the measured lifetime disagrees with the previous Doppler-shift attenuation method measurement by more than 3 σ , while agreeing well with a previous value extracted from Coulomb excitation. The newly extracted B ( E 2 ; 2 1 + → 0 1 + ) value indicates a more significant reduction in the N = 50 isotones approaching Z = 40 .« less
Lifetimes of low-lying excited states in Kr 50 36 86
Henderson, J.; Chester, A.; Ball, G. C.; ...
2018-04-16
b>Bmore » The evolution of nuclear magic numbers at extremes of isospin is a topic at the forefront of contemporary nuclear physics. N = 50 is a prime example, with increasing experimental data coming to light on potentially doubly magic Sn 100 and Ni 78 at the proton-rich and proton-deficient extremes, respectively; however, experimental discrepancies exist in the data for less exotic systems. Purpose: In Kr 86 the B ( E 2 ; 2 1 + → 0 1 + ) value—a key indicator of shell evolution—has been experimentally determined by two different methodologies, with the results deviating by 3 σ . Here, we report on a new high-precision measurement of this value, as well as the first measured lifetimes and hence transition strengths for the 2 2 + and 3 ( 2 ) - states in the nucleus. Methods: The Doppler-shift attenuation method was implemented using the TRIUMF-ISAC γ -ray escape-suppressed spectrometer (TIGRESS) γ -ray spectrometer and the TIGRESS integrated plunger device. High-statistics Monte Carlo simulations were utilized to extract lifetimes in accordance with state-of-the-art methodologies. Results: Lifetimes of τ ( 2 1 + ) = 336 ± 4 (stat.) ± 20 (sys.) fs, τ ( 2 2 + ) = 263 ± 9 (stat.) ± 19 (sys.) fs, and τ ( 3 ( 2 ) - ) = 73 ± 6 (stat.) ± 32 (sys.) fs were extracted. This yields a transition strength for the first-excited state of B ( E 2 ; 2 1 + → 0 1 + ) = 259 ± 3 (stat.) ± 16 (sys.) e 2 fm 4 . Conclusions: Finally, the measured lifetime disagrees with the previous Doppler-shift attenuation method measurement by more than 3 σ , while agreeing well with a previous value extracted from Coulomb excitation. The newly extracted B ( E 2 ; 2 1 + → 0 1 + ) value indicates a more significant reduction in the N = 50 isotones approaching Z = 40 .« less
Asquith, William H.; Herrmann, George R.; Cleveland, Theodore G.
2013-01-01
A database containing more than 17,700 discharge values and ancillary hydraulic properties was assembled from summaries of discharge measurement records for 424 U.S. Geological Survey streamflow-gauging stations (stream gauges) in Texas. Each discharge exceeds the 90th-percentile daily mean streamflow as determined by period-of-record, stream-gauge-specific, flow-duration curves. Each discharge therefore is assumed to represent discharge measurement made during direct-runoff conditions. The hydraulic properties of each discharge measurement included concomitant cross-sectional flow area, water-surface top width, and reported mean velocity. Systematic and statewide investigation of these data in pursuit of regional models for the estimation of discharge and mean velocity has not been previously attempted. Generalized additive regression modeling is used to develop readily implemented procedures by end-users for estimation of discharge and mean velocity from select predictor variables at ungauged stream locations. The discharge model uses predictor variables of cross-sectional flow area, top width, stream location, mean annual precipitation, and a generalized terrain and climate index (OmegaEM) derived for a previous flood-frequency regionalization study. The mean velocity model uses predictor variables of discharge, top width, stream location, mean annual precipitation, and OmegaEM. The discharge model has an adjusted R-squared value of about 0.95 and a residual standard error (RSE) of about 0.22 base-10 logarithm (cubic meters per second); the mean velocity model has an adjusted R-squared value of about 0.67 and an RSE of about 0.063 fifth root (meters per second). Example applications and computations using both regression models are provided. - See more at: http://ascelibrary.org/doi/abs/10.1061/%28ASCE%29HE.1943-5584.0000635#sthash.jhGyPxgZ.dpuf
Polarographic determination of lead hydroxide formation constants at low ionic strength
Lind, Carol J.
1978-01-01
Values of formation constants for lead hydroxide at 25 ??C were calculated from normal pulse polarographic measurements of 10-6 M lead in 0.01 M sodium perchlorate. The low concentrations simulate those found in many freshwaters, permitting direct application of the values when considering distributions of lead species. The precise evaluation of species distribution in waters at other ionic strengths requires activity coefficient corrections. As opposed to much of the previously published work done at high ionic strength, the values reported here were obtained at low ionic strength, permitting use of smaller and better defined activity coefficient corrections. These values were further confirmed by differential-pulse polarography and differential-pulse anodic stripping voltammetry data. The logs of the values for ??1??? ??2???, and ??3??? were calculated to be 6.59, 10.80, and 13.63, respectively. When corrected to zero ionic strength these values were calculated to be 6.77, 11.07, and 13.89, respectively.
NASA Technical Reports Server (NTRS)
1974-01-01
This report presents the derivation, description, and operating instructions for a computer program (TEKVAL) which measures the economic value of advanced technology features applied to long range commercial passenger aircraft. The program consists of three modules; and airplane sizing routine, a direct operating cost routine, and an airline return-on-investment routine. These modules are linked such that they may be operated sequentially or individually, with one routine generating the input for the next or with the option of externally specifying the input for either of the economic routines. A very simple airplane sizing technique was previously developed, based on the Brequet range equation. For this program, that sizing technique has been greatly expanded and combined with the formerly separate DOC and ROI programs to produce TEKVAL.
Measurement of Γee(J /ψ) with KEDR detector
NASA Astrophysics Data System (ADS)
Anashin, V. V.; Aulchenko, V. M.; Baldin, E. M.; Barladyan, A. K.; Barnyakov, A. Y.; Barnyakov, M. Y.; Baru, S. E.; Bedny, I. V.; Blinov, A. E.; Blinov, V. E.; Bobrov, A. V.; Bobrovnikov, V. S.; Bogomyagkov, A. V.; Bondar, A. E.; Bondarev, D. V.; Buzykaev, A. R.; Eidelman, S. I.; Glukhovchenko, Y. M.; Gulevich, V. V.; Gusev, D. V.; Karnaev, S. E.; Karpov, G. V.; Karpov, S. V.; Kharlamova, T. A.; Kiselev, V. A.; Kononov, S. A.; Kotov, K. Y.; Kravchenko, E. A.; Kulikov, V. F.; Kurkin, G. Y.; Kuper, E. A.; Levichev, E. B.; Maksimov, D. A.; Malyshev, V. M.; Maslennikov, A. L.; Medvedko, A. S.; Meshkov, O. I.; Mishnev, S. I.; Morozov, I. I.; Muchnoi, N. Y.; Neufeld, V. V.; Nikitin, S. A.; Nikolaev, I. B.; Okunev, I. N.; Onuchin, A. P.; Oreshkin, S. B.; Orlov, I. O.; Osipov, A. A.; Peleganchuk, S. V.; Pivovarov, S. G.; Piminov, P. A.; Petrov, V. V.; Poluektov, A. O.; Popkov, I. N.; Prisekin, V. G.; Rezanova, O. L.; Ruban, A. A.; Sandyrev, V. K.; Savinov, G. A.; Shamov, A. G.; Shatilov, D. N.; Shwartz, B. A.; Simonov, E. A.; Sinyatkin, S. V.; Skovpen, Y. I.; Skrinsky, A. N.; Smaluk, V. V.; Sokolov, A. V.; Sukharev, A. M.; Starostina, E. V.; Talyshev, A. A.; Tayursky, V. A.; Telnov, V. I.; Tikhonov, Y. A.; Todyshev, K. Y.; Tumaikin, G. M.; Usov, Y. V.; Vorobiov, A. I.; Yushkov, A. N.; Zhilich, V. N.; Zhulanov, V. V.; Zhuravlev, A. N.
2018-05-01
The product of the electronic width of the J/ψ meson and the branching fractions of its decay to hadrons and electrons has been measured using the KEDR detector at the VEPP-4M e + e - collider. The obtained values are Γ_{ee}(J/ψ )=5.550± 0.056± 0.089 Γ_{ee}(J/ψ )\\cdotp B_{hadrons}(J/ψ )=4.884± 0.048± 0.078 keV Γ_{ee}(J/ψ )\\cdotp B_{ee}(J/ψ )=0.3331± 0.0066± 0.0040 keV. The uncertainties shown are statistical and systematic, respectively. Using the result presented and the world-average value of the electronic branching fraction, one obtains the total width of the J/ψ meson: Γ =92.94± 1.83keV. These results are consistent with the previous experiments.
NASA Astrophysics Data System (ADS)
Gray, T. J.; Stuchbery, A. E.; Reed, M. W.; Akber, A.; Coombes, B. J.; Dowie, J. T. H.; Eriksen, T. K.; Gerathy, M. S. M.; Kibédi, T.; Lane, G. J.; Mitchell, A. J.; Palazzo, T.; Tornyi, T.
2017-11-01
The time differential perturbed angular distribution technique with LaBr3 detectors has been applied to the Iπ=11/2- isomeric state (Ex=846 keV, τ =107 ns) in 107Cd, which was populated and recoil-implanted into a gadolinium host following the 98Mo(12C, 3 n )107Cd reaction. The static hyperfine field strength of Cd recoil implanted into gadolinium was thus measured, together with the fraction of nuclei implanted into field-free sites, under similar conditions as pertained for a previous implantation perturbed angular distribution g -factor measurement on the Iπ=10+ state in 110Cd. The 110Cdg (10+) value was thereby reevaluated, bringing it into agreement with the value expected for a seniority-two ν h11/2 configuration.
Measurement of the Fluorescence Lifetime of Chlorophyll a In Vivo
Singhal, G. S.; Rabinowitch, E.
1969-01-01
New measurements have been made of fluorescence lifetime (τ) of chlorophyll a in the algae Chlorella pyrenoidosa, Porphyridium cruentum, Anacystis nidulans, and in spinach chloroplast. τ-values of 0.6 and 0.7 nsec were obtained with green plants. Anacystis and Porphyridium gave a τ of 0.5 nsec. The previously described two stage decay of fluorescence in vivo in these organisms could not be confirmed. This observation could have been caused by a second wave of light emission from the exciting hydrogen lamp (not detected in earlier work). The lifetimes found in this study (calculated, as before, by the method of convolution integrals) were close to those found by other observers for “low” excitation intensities; the value first reported from this laboratory (1.0-1.7 nsec) may have corresponded to “high” excitation intensity. PMID:5778187
Measurement of |V{sub ub}| from Inclusive Charmless Semileptonic B Decays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Urquijo, P.; Barberio, E.; Limosani, A.
2010-01-15
We present the partial branching fraction for inclusive charmless semileptonic B decays and the corresponding value of the Cabibbo-Kobayashi-Maskawa matrix element |V{sub ub}|, using a multivariate analysis method to access {approx}90% of the B->X{sub u}lnu phase space. This approach dramatically reduces the theoretical uncertainties from the b-quark mass and nonperturbative QCD compared to all previous inclusive measurements. The results are based on a sample of 657x10{sup 6} BB pairs collected with the Belle detector. We find that {Delta}B(B->X{sub u}l{nu};p{sub l}{sup *B}>1.0 GeV/c)=1.963x(1+-0.088{sub stat}+-0.081{sub syst})x10{sup -3}. Corresponding values of |V{sub ub}| are extracted using several theoretical calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devic, Slobodan; Tomic, Nada; Aldelaijan, Saad
Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to testmore » the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%/3 mm for an IMRT QA plan and 3%/2 mm for a brachytherapy QA plan are passing 95% gamma function points. Conclusions: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.« less
Calibrating the Planck Cluster Mass Scale with Cluster Velocity Dispersions
NASA Astrophysics Data System (ADS)
Amodeo, Stefania; Mei, Simona; Stanford, Spencer A.; Bartlett, James G.; Melin, Jean-Baptiste; Lawrence, Charles R.; Chary, Ranga-Ram; Shim, Hyunjin; Marleau, Francine; Stern, Daniel
2017-08-01
We measure the Planck cluster mass bias using dynamical mass measurements based on velocity dispersions of a subsample of 17 Planck-detected clusters. The velocity dispersions were calculated using redshifts determined from spectra that were obtained at the Gemini observatory with the GMOS multi-object spectrograph. We correct our estimates for effects due to finite aperture, Eddington bias, and correlated scatter between velocity dispersion and the Planck mass proxy. The result for the mass bias parameter, (1-b), depends on the value of the galaxy velocity bias, {b}{{v}}, adopted from simulations: (1-b)=(0.51+/- 0.09){b}{{v}}3. Using a velocity bias of {b}{{v}}=1.08 from Munari et al., we obtain (1-b)=0.64+/- 0.11, I.e., an error of 17% on the mass bias measurement with 17 clusters. This mass bias value is consistent with most previous weak-lensing determinations. It lies within 1σ of the value that is needed to reconcile the Planck cluster counts with the Planck primary cosmic microwave background constraints. We emphasize that uncertainty in the velocity bias severely hampers the precision of the measurements of the mass bias using velocity dispersions. On the other hand, when we fix the Planck mass bias using the constraints from Penna-Lima et al., based on weak-lensing measurements, we obtain a positive velocity bias of {b}{{v}}≳ 0.9 at 3σ .
Grammer, K. B.; Alarcon, R.; Barrón-Palos, L.; ...
2015-05-08
Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many-body physics. Unfortunately, the pair correlation function g(r) inferred from neutron scattering measurements of the differential cross section dσ/dΩ from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43 and 16.1 meV on liquid hydrogen at 15.6 K (which is dominated by the parahydrogen component)more » using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1 meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra nonequilibrium component of orthohydrogen. Liquid parahydrogen is also a widely used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. Furthermore, we describe our measurements and compare them with previous work.« less
Water vapor self-continuum absorption measurements in the 4.0 and 2.1 μm transparency windows
NASA Astrophysics Data System (ADS)
Richard, L.; Vasilchenko, S.; Mondelain, D.; Ventrillard, I.; Romanini, D.; Campargue, A.
2017-11-01
In a recent contribution [A. Campargue, S. Kassi, D. Mondelain, S. Vasilchenko, D. Romanini, Accurate laboratory determination of the near infrared water vapor self-continuum: A test of the MT_CKD model. J. Geophys. Res. Atmos., 121,13,180-13,203, doi:10.1002/2016JD025531], we reported accurate water vapor absorption continuum measurements by Cavity Ring-down Spectroscopy (CRDS) and Optical-Feedback-Cavity Enhanced Absorption Spectroscopy (OF-CEAS) at selected spectral points of 4 near infrared transparency windows. In the present work, the self-continuum cross-sections, CS, are determined for two new spectral points. The 2491 cm-1 spectral point in the region of maximum transparency of the 4.0 μm window was measured by OF-CEAS in the 23-52 °C temperature range. The 4435 cm-1 spectral point of the 2.1 μm window was measured by CRDS at room temperature. The self-continuum cross-sections were determined from the pressure squared dependence of the continuum absorption. Comparison to the literature shows a reasonable agreement with 1970 s and 1980 s measurements using a grating spectrograph in the 4.0 μm window and a very good consistency with our previous laser measurements in the 2.1 μm window. For both studied spectral points, our values are much smaller than previous room temperature measurements by Fourier Transform Spectroscopy. Significant deviations (up to about a factor 4) are noted compared to the widely used semi empirical MT_CKD model of the absorption continuum. The measured temperature dependence at 2491 cm-1 is consistent with previous high temperature measurements in the 4.0 μm window and follows an exp(D0/kT) law, D0 being the dissociation energy of the water dimer.
Deep Atmosphere Ammonia Mixing Ratio at Jupiter from the Galileo Probe Mass Spectrometer
NASA Technical Reports Server (NTRS)
Mahaffy, P. R.; Niemann, H. B.; Demick, J. E.
1999-01-01
New laboratory studies employing the Engineering Unit (EU) of the Galileo Probe Mass Spectrometer (GPMS) have resulted in a substantial reduction in the previously reported upper limit on the ammonia mixing ratio derived from the GPMS experiment at Jupiter. This measurement is complicated by background ammonia contributions in the GPMS during direct atmospheric sampling produced from the preceding gas enrichment experiments. These backgrounds can be quantified with the data from the EU studies when they are carried out in a manner that duplicates the descent profile of pressure and enrichment cell loading. This background is due to the tendency of ammonia to interact strongly with the walls of the mass spectrometer and on release to contribute to the gas being directly directed into the ion source from the atmosphere through a capillary pressure reduction leak. It is evident from the GPMS and other observations that the mixing ratio of ammonia at Jupiter reaches the deep atmosphere value at substantially higher pressures than previously assumed. This is a likely explanation for the previously perceived discrepancy between ammonia values derived from ground based microwave observations and those obtained from attenuation of the Galileo Probe radio signal.
On the relationship between NMR-derived amide order parameters and protein backbone entropy changes
Sharp, Kim A.; O’Brien, Evan; Kasinath, Vignesh; Wand, A. Joshua
2015-01-01
Molecular dynamics simulations are used to analyze the relationship between NMR-derived squared generalized order parameters of amide NH groups and backbone entropy. Amide order parameters (O2NH) are largely determined by the secondary structure and average values appear unrelated to the overall flexibility of the protein. However, analysis of the more flexible subset (O2NH < 0.8) shows that these report both on the local flexibility of the protein and on a different component of the conformational entropy than that reported by the side chain methyl axis order parameters, O2axis. A calibration curve for backbone entropy vs. O2NH is developed which accounts for both correlations between amide group motions of different residues, and correlations between backbone and side chain motions. This calibration curve can be used with experimental values of O2NH changes obtained by NMR relaxation measurements to extract backbone entropy changes, e.g. upon ligand binding. In conjunction with our previous calibration for side chain entropy derived from measured O2axis values this provides a prescription for determination of the total protein conformational entropy changes from NMR relaxation measurements. PMID:25739366
On the relationship between NMR-derived amide order parameters and protein backbone entropy changes.
Sharp, Kim A; O'Brien, Evan; Kasinath, Vignesh; Wand, A Joshua
2015-05-01
Molecular dynamics simulations are used to analyze the relationship between NMR-derived squared generalized order parameters of amide NH groups and backbone entropy. Amide order parameters (O(2) NH ) are largely determined by the secondary structure and average values appear unrelated to the overall flexibility of the protein. However, analysis of the more flexible subset (O(2) NH < 0.8) shows that these report both on the local flexibility of the protein and on a different component of the conformational entropy than that reported by the side chain methyl axis order parameters, O(2) axis . A calibration curve for backbone entropy vs. O(2) NH is developed, which accounts for both correlations between amide group motions of different residues, and correlations between backbone and side chain motions. This calibration curve can be used with experimental values of O(2) NH changes obtained by NMR relaxation measurements to extract backbone entropy changes, for example, upon ligand binding. In conjunction with our previous calibration for side chain entropy derived from measured O(2) axis values this provides a prescription for determination of the total protein conformational entropy changes from NMR relaxation measurements. © 2015 Wiley Periodicals, Inc.
Elongated Tetrakaidecahedron Micromechanics Model for Space Shuttle External Tank Foams
NASA Technical Reports Server (NTRS)
Sullivan, Roy M.; Ghosn, Louis J.; Lerch, Bradley A.; Baker, Eric H.
2009-01-01
The results of microstructural characterization studies and physical and mechanical testing of BX-265 and NCFI24-124 foams are reported. A micromechanics model developed previously by the authors is reviewed, and the resulting equations for the elastic constants, the relative density, and the strength of the foam in the principal material directions are presented. The micromechanics model is also used to derive equations to predict the effect of vacuum on the tensile strength and the strains induced by exposure to vacuum. Using a combination of microstructural dimensions and physical and mechanical measurements as input, the equations for the elastic constants and the relative density are applied and the remaining microstructural dimensions are predicted. The predicted microstructural dimensions are in close agreement with the average measured values for both BX-265 and NCFI24-124. With the microstructural dimensions, the model predicts the ratio of the strengths in the principal material directions for both foams. The model is also used to predict the Poisson s ratios, the vacuum-induced strains, and the effect of vacuum on the tensile strengths. However, the comparison of these predicted values with the measured values is not as favorable.
Interstitial water studies on small core samples, Deep Sea Drilling Project, Leg 6
Manheim, F. T.; Sayles, F.L.
1971-01-01
Sediments from Leg 6 sites, west of the Hawaiian Islands, consisted primarily of various combinations of deep-sea biogenic oozes, volcanic ash, and its breakdown products. Pore fluids from most of the sites were similar in composition to present day ocean water, and in some sties almost identical. However, interstitial fluids from Site 53 (Philippine Sea) showed changes in ionic composition which were beyond those previously considered attributable to diagenetic influence. These samples show the beginnings of metamorphism by dramatic increases in calcium concentrations and corresponding decreases in alkali concentrations. Analytical methods were similar to those outlined in previous Leg Reports. However, obvious contamination of aliquots for sodium determination in the laboratory made it necessary to determine all sodium values by difference between anion and cation balances. These values are, if anything, more accurate than direct determinations which have been discussed in earlier legs. However, the authors will continue to analyze sodium directly, and in the future they may be able to improve the precision of the determinations to the point where small losses and gains of sodium in the pore fluids may be established accurately. Agreement between colorimetric and spectrometric determinations of silicon has improved, but there are still occasional marked differences for which the writers have no explanation. T. Takahashi has allowed the authors to compare total Carbon Dioxide (CO2) measurements from his laboratory with their alkalinity determinations: both sets of data were obtained from fluids from the same squeezings of sediments and should give similar values at the indicated pH levels. Some disturbingly large discrepancies in the two sets of data are evident. The authors do not think that their back-titration alkalinity technique alone is responsible for the differences. However, they have not evaluated the possible influence of the heat-sealed polyethylene pipes on the alkalinity values; this should be considered a potential source of error. The pH data from water samples processed and measured on shipboard are reported here. In view of the major changes in pressure and temperature (laboratory temperatures were reported to be 26 to 28°C) and the sediments to new gaseous regimes prior to pH measurement, these values should be interpreted mainly as applying to the squeezed effluents, not to in situ values.
Experimental violation of a Bell's inequality with efficient detection.
Rowe, M A; Kielpinski, D; Meyer, V; Sackett, C A; Itano, W M; Monroe, C; Wineland, D J
2001-02-15
Local realism is the idea that objects have definite properties whether or not they are measured, and that measurements of these properties are not affected by events taking place sufficiently far away. Einstein, Podolsky and Rosen used these reasonable assumptions to conclude that quantum mechanics is incomplete. Starting in 1965, Bell and others constructed mathematical inequalities whereby experimental tests could distinguish between quantum mechanics and local realistic theories. Many experiments have since been done that are consistent with quantum mechanics and inconsistent with local realism. But these conclusions remain the subject of considerable interest and debate, and experiments are still being refined to overcome 'loopholes' that might allow a local realistic interpretation. Here we have measured correlations in the classical properties of massive entangled particles (9Be+ ions): these correlations violate a form of Bell's inequality. Our measured value of the appropriate Bell's 'signal' is 2.25 +/- 0.03, whereas a value of 2 is the maximum allowed by local realistic theories of nature. In contrast to previous measurements with massive particles, this violation of Bell's inequality was obtained by use of a complete set of measurements. Moreover, the high detection efficiency of our apparatus eliminates the so-called 'detection' loophole.
Comparison of non-invasive MRI measurements of cerebral blood flow in a large multisite cohort.
Dolui, Sudipto; Wang, Ze; Wang, Danny Jj; Mattay, Raghav; Finkel, Mack; Elliott, Mark; Desiderio, Lisa; Inglis, Ben; Mueller, Bryon; Stafford, Randall B; Launer, Lenore J; Jacobs, David R; Bryan, R Nick; Detre, John A
2016-07-01
Arterial spin labeling and phase contrast magnetic resonance imaging provide independent non-invasive methods for measuring cerebral blood flow. We compared global cerebral blood flow measurements obtained using pseudo-continuous arterial spin labeling and phase contrast in 436 middle-aged subjects acquired at two sites in the NHLBI CARDIA multisite study. Cerebral blood flow measured by phase contrast (CBFPC: 55.76 ± 12.05 ml/100 g/min) was systematically higher (p < 0.001) and more variable than cerebral blood flow measured by pseudo-continuous arterial spin labeling (CBFPCASL: 47.70 ± 9.75). The correlation between global cerebral blood flow values obtained from the two modalities was 0.59 (p < 0.001), explaining less than half of the observed variance in cerebral blood flow estimates. Well-established correlations of global cerebral blood flow with age and sex were similarly observed in both CBFPCASL and CBFPC CBFPC also demonstrated statistically significant site differences, whereas no such differences were observed in CBFPCASL No consistent velocity-dependent effects on pseudo-continuous arterial spin labeling were observed, suggesting that pseudo-continuous labeling efficiency does not vary substantially across typical adult carotid and vertebral velocities, as has previously been suggested. Although CBFPCASL and CBFPC values show substantial similarity across the entire cohort, these data do not support calibration of CBFPCASL using CBFPC in individual subjects. The wide-ranging cerebral blood flow values obtained by both methods suggest that cerebral blood flow values are highly variable in the general population. © The Author(s) 2016.
Activation energy of extracellular enzymes in soils from different biomes.
Steinweg, J Megan; Jagadamma, Sindhu; Frerichs, Joshua; Mayes, Melanie A
2013-01-01
Enzyme dynamics are being incorporated into soil carbon cycling models and accurate representation of enzyme kinetics is an important step in predicting belowground nutrient dynamics. A scarce number of studies have measured activation energy (Ea) in soils and fewer studies have measured Ea in arctic and tropical soils, or in subsurface soils. We determined the Ea for four typical lignocellulose degrading enzymes in the A and B horizons of seven soils covering six different soil orders. We also elucidated which soil properties predicted any measurable differences in Ea. β-glucosidase, cellobiohydrolase, phenol oxidase and peroxidase activities were measured at five temperatures, 4, 21, 30, 40, and 60°C. Ea was calculated using the Arrhenius equation. β-glucosidase and cellobiohydrolase Ea values for both A and B horizons in this study were similar to previously reported values, however we could not make a direct comparison for B horizon soils because of the lack of data. There was no consistent relationship between hydrolase enzyme Ea and the environmental variables we measured. Phenol oxidase was the only enzyme that had a consistent positive relationship between Ea and pH in both horizons. The Ea in the arctic and subarctic zones for peroxidase was lower than the hydrolases and phenol oxidase values, indicating peroxidase may be a rate limited enzyme in environments under warming conditions. By including these six soil types we have increased the number of soil oxidative enzyme Ea values reported in the literature by 50%. This study is a step towards better quantifying enzyme kinetics in different climate zones.
Henry, C Jeya K; Lightowler, Helen J; Dodwell, Lis M; Wynne, Jacqueline M
2007-07-01
There is currently an increased global interest in the published glycaemic index (GI) values of foods. The aim of the present work was to supplement a previous study on the glycaemic response of 140 foods available in the UK by studying a further forty-four foods. One hundred and twenty-two healthy subjects, with a mean age of 32.4 (sd 11.4) years and a mean BMI of 23.6 (sd 3.6) kg/m2, were recruited to the study. Subjects were served equivalent available carbohydrate amounts (50 or 30 g) of test foods (cereal products and weight-management meals) and a standard food (glucose) on separate occasions. Capillary blood glucose was measured from finger-prick samples in fasted subjects (0 min) and at 15, 30, 45, 60, 90 and 120 min after starting to eat each test food. For each test food, the GI value was determined, and the glycaemic load was calculated as the product of the GI and the amount of available carbohydrate in a reference serving size. The GI values of the foods tested ranged from 23 to 83. Of the forty-four foods tested, thirty-three were classified as low-GI, eight as medium-GI and three as high-GI foods. Most GI values of the foods tested compared well with previously published values for similar foods. In summary, this study provides reliable GI and glycaemic load values for a range of foods, further advancing our understanding of the glycaemic response of different foods. The data reported here make an important addition to published GI values.
O’Grady, Shannon P.; Valenzuela, Luciano O.; Remien, Christopher H.; Enright, Lindsey E.; Jorgensen, Matthew J.; Kaplan, Jay R.; Wagner, Janice D.; Cerling, Thure E.; Ehleringer, James R.
2012-01-01
The stable isotopic composition of drinking water, diet, and atmospheric oxygen influence the isotopic composition of body water (2H/1H, 18O/16O expressed as δ2H and δ18O). In turn, body water influences the isotopic composition of organic matter in tissues, such as hair and teeth, which are often used to reconstruct historical dietary and movement patterns of animals and humans. Here, we used a nonhuman primate system (Macaca fascicularis) to test the robustness of two different mechanistic stable isotope models: a model to predict the δ2H and δ18O values of body water and a second model to predict the δ2H and δ18O values of hair. In contrast to previous human-based studies, use of nonhuman primates fed controlled diets allowed us to further constrain model parameter values and evaluate model predictions. Both models reliably predicted the δ2H and δ18O values of body water and of hair. Moreover, the isotope data allowed us to better quantify values for two critical variables in the models: the δ2H and δ18O values of gut water and the 18O isotope fractionation associated with a carbonyl oxygen-water interaction in the gut (αow). Our modeling efforts indicated that better predictions for body water and hair isotope values were achieved by making the isotopic composition of gut water approached that of body water. Additionally, the value of αow was 1.0164, in close agreement with the only other previously measured observation (microbial spore cell walls), suggesting robustness of this fractionation factor across different biological systems. PMID:22553163
O'Grady, Shannon P; Valenzuela, Luciano O; Remien, Christopher H; Enright, Lindsey E; Jorgensen, Matthew J; Kaplan, Jay R; Wagner, Janice D; Cerling, Thure E; Ehleringer, James R
2012-07-01
The stable isotopic composition of drinking water, diet, and atmospheric oxygen influence the isotopic composition of body water ((2)H/(1)H, (18)O/(16)O expressed as δ(2) H and δ(18)O). In turn, body water influences the isotopic composition of organic matter in tissues, such as hair and teeth, which are often used to reconstruct historical dietary and movement patterns of animals and humans. Here, we used a nonhuman primate system (Macaca fascicularis) to test the robustness of two different mechanistic stable isotope models: a model to predict the δ(2)H and δ(18)O values of body water and a second model to predict the δ(2)H and δ(18)O values of hair. In contrast to previous human-based studies, use of nonhuman primates fed controlled diets allowed us to further constrain model parameter values and evaluate model predictions. Both models reliably predicted the δ(2)H and δ(18)O values of body water and of hair. Moreover, the isotope data allowed us to better quantify values for two critical variables in the models: the δ(2)H and δ(18)O values of gut water and the (18)O isotope fractionation associated with a carbonyl oxygen-water interaction in the gut (α(ow)). Our modeling efforts indicated that better predictions for body water and hair isotope values were achieved by making the isotopic composition of gut water approached that of body water. Additionally, the value of α(ow) was 1.0164, in close agreement with the only other previously measured observation (microbial spore cell walls), suggesting robustness of this fractionation factor across different biological systems. © 2012 Wiley Periodicals, Inc.
Mars Methane highs unrelated to comets
NASA Astrophysics Data System (ADS)
Roos-Serote, Maarten; Atreya, Sushil K.; Webster, Chris; Mahaffy, Paul
2016-10-01
Until the Curiosity Rover arrived at Mars, all measurements of methane were done by remote sensing, either from Earth or from orbiting spacecraft, using a variety of different instruments and under different observing conditions. The Curiosity Rover's Sample Analysis at Mars (SAM) / Tunable Laser Spectrometer (TLS) has carried out systematic measurements of martian methane from Gale crater for two consecutive martian years (31 - 33, starting in October 2012). Meteoric material interacts with the martian atmosphere when Mars passes through a meteoroid stream left behind by cometary bodies orbiting the Sun. Predictions show that 33 such events are likely to occur during the martian year. It has been suggested that the organics present in this material trigger the formation of methane in the atmosphere, and thus these events could possibly be an explanation for the observed variations in the methane abundance. In a recent paper, Fries et al. [2016] argued that all measurements of high methane concentrations are within 16 days of a predicted meteor shower event, and that as such there is a correlation. We present a new analysis including seven new data points that were not available previously. All these new measurements show low methane values. Some of the new measurements were deliberately taken at the same Ls when high values of methane were measured in the previous martian year, showing that the high methane measurements are likely not seasonal, as would be expected if they were connected to meteor shower events. In our analysis we take into account all the predicted meteor events and search for any correlation drawn between these events and the level of methane in the atmosphere. We conclude that whether we consider individual data points, apply statistical analysis, or consider different time spans between measurements and the occurrence of meteor events, or possible supply of organic material from comets, there is no evidence for such a correlation in the available data.
Scanning-slit topography in patients with keratoconus.
Módis, László; Németh, Gábor; Szalai, Eszter; Flaskó, Zsuzsa; Seitz, Berthold
2017-01-01
To evaluate the anterior and posterior corneal surfaces using scanning-slit topography and to determine the diagnostic ability of the measured corneal parameters in keratoconus. Orbscan II measurements were taken in 39 keratoconic corneas previously diagnosed by corneal topography and in 39 healthy eyes. The central minimum, maximum, and astigmatic simulated keratometry (K) and anterior axial power values were determined. Spherical and cylindrical mean power diopters were obtained at the central and at the steepest point of the cornea both on anterior and on posterior mean power maps. Pachymetry evaluations were taken at the center and paracentrally in the 3 mm zone from the center at a location of every 45 degrees. Receiver operating characteristic (ROC) analysis was used to determine the best cut-off values and to evaluate the utility of the measured parameters in identifying patients with keratoconus. The minimum, maximum and astigmatic simulated K readings were 44.80±3.06 D, 47.17±3.67 D and 2.42±1.84 D respectively in keratoconus patients and these values differed significantly ( P <0.0001 for all comparisons) from healthy subjects. For all pachymetry measurements and for anterior and posterior mean power values significant differences were found between the two groups. Moreover, anterior central cylindrical power had the best discrimination ability (area under the ROC curve=0.948). The results suggest that scanning-slit topography and pachymetry are accurate methods both for keratoconus screening and for confirmation of the diagnosis.
Do functional tests predict low back pain?
Takala, E P; Viikari-Juntura, E
2000-08-15
A cohort of 307 nonsymptomatic workers and another cohort of 123 workers with previous episodes of low back pain were followed up for 2 years. The outcomes were measured by symptoms, medical consultations, and sick leaves due to low back disorders. To study the predictive value of a set of tests measuring the physical performance of the back in a working population. The hypothesis was that subjects with poor functional capacity are liable to back disorders. Reduced functional performance has been associated with back pain. There are few data to show whether reduced functional capacity is a cause or a consequence of pain. Mobility of the trunk in forward and side bending, maximal isokinetic trunk extension, flexion and lifting strength, and static endurance of back extension were measured. Standing balance and foot reaction time were recorded with a force plate. Clinical tests for the provocation of back or leg pain were performed. Gender, workload, age, and anthropometrics were managed as potential confounders in the analysis. Marked overlapping was seen in the measures of the subjects with different outcomes. Among the nonsymptomatic subjects, low performance in tests of mobility and standing balance was associated with future back disorders. Among workers with previous episodes of back pain, low isokinetic extension strength, poor standing balance, and positive clinical signs predicted future pain. Some associations were found between the functional tests and future low back pain. The wide variation in the results questions the value of the tests in health examinations (e.g., in screening or surveillance of low back disorders).
Sales-Sanz, Marco; Arranz-Marquez, Esther; Piñero, David P; Arruabarrena, Carolina; Mikropoulos, Dimitrios G; Teus, Miguel A
2016-04-01
To assess the effect of laser in situ keratomileusis (LASIK) on ocular rigidity and compare its effect on intraocular pressure (IOP) readings with Goldmann applanation tonometry (GAT), Schiøtz indentation tonometry (ST), and dynamic contour tonometry (DCT). Prospective, observational, single-masked study. Eighty-one patients who underwent myopic LASIK and 108 unoperated myopic control patients were included in the study. The IOP was measured using GAT, DCT, and ST. The coefficient of ocular rigidity (Ko) was obtained from the regression analysis of the 3 readings obtained with each weight of the ST. Linear multiple regression analysis was performed with dummy variables to assess the effects of age, central corneal thickness (CCT), and refractive surgery on measured IOP values. Age, CCT, and previous LASIK explained 39.41% of the IOP readings with GAT, 25.31% with DCT, and 3.28% with ST. LASIK caused a mean decrease of -2.51 mm Hg in IOP readings (P=0.000) with GAT, -1.29 mm Hg (P=0.036) with DCT, and no significant change in IOP readings with ST (P=0.299). Significant differences in the Ko were observed between the LASIK and control groups. The Ko values were unrelated to age and CCT in the LASIK and control groups. ST seems to be less affected by previous LASIK procedures. There is a difference in the ocular rigidity between the unoperated and LASIK eyes that is not correlated with the CCT. Therefore, ST seems to measure changes in the biomechanical behavior of corneas that underwent LASIK surgery.
Role of collateral paths in long-range diffusion in lungs
Bartel, Seth-Emil T.; Haywood, Susan E.; Woods, Jason C.; Chang, Yulin V.; Menard, Christopher; Yablonskiy, Dmitriy A.; Gierada, David S.; Conradi, Mark S.
2010-01-01
The long-range apparent diffusion coefficient (LRADC) of 3He gas in lungs, measured over times of several seconds and distances of 1–3 cm, probes the connections between the airways. Previous work has shown the LRADC to be small in health and substantially elevated in emphysema, reflecting tissue destruction, which is known to create collateral pathways. To better understand what controls LRADC, we report computer simulations and measurements of 3He gas diffusion in healthy lungs. The lung is generated with a random algorithm using well-defined rules, yielding a three-dimensional set of nodes or junctions, each connected by airways to one parent node and two daughters; airway dimensions are taken from published values. Spin magnetization in the simulated lung is modulated sinusoidally, and the diffusion equation is solved to 1,000 s. The modulated magnetization decays with a time constant corresponding to an LRADC of ~0.001 cm2/s, which is smaller by a factor of ~20 than the values in healthy lungs measured here and previously in vivo and in explanted lungs. It appears that collateral gas pathways, not present in the simulations, are functional in healthy lungs; they provide additional and more direct routes for long-range motion than the canonical airway tree. This is surprising, inasmuch as collateral ventilation is believed to be physiologically insignificant in healthy lungs. We discuss the effect on LRADC of small collateral connections through airway walls and rule out other possible mechanisms. The role of collateral paths is supported by measurements of smaller LRADC in pigs, where collateral ventilation is known to be smaller. PMID:18292298
Seker, Ayse; Demirci, Hakan; Ocakoglu, Gokhan; Aydin, Ufuk; Ucar, Hakan; Yildiz, Gursel; Yaman, Ozen
2017-10-01
We aimed to analyze the difference in 24-h blood pressure values during Ramadan of fasting and nonfasting individuals with no previous history of hypertension. This study was planned as a multicenter research study in the cities of Izmit, Zonguldak, Sivas, and Adana. The percentage changes in the blood pressure of the patients were calculated from their blood pressure measurements at 0 h while they were resting. A Food Frequency Questionnaire was filled out by all participants. Forty patients were included in the fasting group and 55 patients were included in the nonfasting group in the study. There was a difference between the two groups in percent changes of systolic measurements performed at the 4th (5% difference and P=0.020), 13th (6% difference and P=0.015), 14th (10% difference and P=0.017), 18th (9% difference and P=0.027), 19th (9% difference and P=0.020), and 20th (6% difference and P=0.014) hours with respect to the baseline measurement at the 0 h. There was a difference between the fasting and nonfasting groups in the Fasting Food Questionnaire results. Meat consumption was significantly higher in the fasting group. A systolic blood pressure increase in fasting patients was observed in measurements at 18:00, 19:00, and 20:00 h. We believe that an increase of more than 10% in blood pressure at the time of iftar is an important result of our study in terms of the meal preferences of the individuals under risk.
West, John B; Crouch, Daniel R; Fine, Janelle M; Makadia, Dipen; Wang, Daniel L; Prisk, G Kim
2018-02-13
It would be valuable to have a noninvasive method of measuring impaired pulmonary gas exchange in patients with lung disease and thus reduce the need for repeated arterial punctures. This study reports the results of using a new test in a group of outpatients attending a pulmonary clinic. Inspired and expired partial pressure of oxygen (PO 2 ) and Pco 2 are continually measured by small, rapidly responding analyzers. The arterial PO 2 is calculated from the oximeter blood oxygen saturation level and the oxygen dissociation curve. The PO 2 difference between the end-tidal gas and the calculated arterial value is called the oxygen deficit. Studies on 17 patients with a variety of pulmonary diseases are reported. The mean ± SE oxygen deficit was 48.7 ± 3.1 mm Hg. This finding can be contrasted with a mean oxygen deficit of 4.0 ± 0.88 mm Hg in a group of 31 normal subjects who were previously studied (P < .0001). The analysis emphasizes the value of measuring the composition of alveolar gas in determining ventilation-perfusion ratio inequality. This factor is largely ignored in the classic index of impaired pulmonary gas exchange using the ideal alveolar PO 2 to calculate the alveolar-arterial oxygen gradient. The results previously reported in normal subjects and the present studies suggest that this new noninvasive test will be valuable in assessing abnormal gas exchange in the clinical setting. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Carbon budget for a British upland peat catchment.
Worrall, Fred; Reed, Mark; Warburton, Jeff; Burt, Tim
2003-08-01
This study describes the analysis of fluvial carbon flux from an upland peat catchment in the North Pennines. Dissolved organic carbon (DOC), pH, alkalinity and calcium were measured in weekly samples, with particulate organic carbon (POC) measured from the suspended sediment load from the stream outlet of an 11.4-km(2) catchment. For calendar year 1999, regular monitoring of the catchment was supplemented with detailed quasi-continuous measurements of flow and stream temperature, and DOC for the months September through November. The measurements were used to calculate the annual flux of dissolved CO(2), dissolved inorganic carbon, DOC and POC from the catchment and were combined with CO(2) and CH(4) gaseous exchanges calculated from previously published values and the observations of water table height within the peat. The study catchment represents a net sink of 15.4+/-11.9 gC/m(2)/yr. Carbon flows calculated for the study catchment are combined with values in the literature, using a Monte Carlo method, to estimate the carbon budget for British upland peat. For all British upland peat the calculation suggests a net carbon sink of between 0.15 and 0.29 MtC/yr. This is the first study to include a comprehensive study of the fluvial export of carbon within carbon budgets and shows the size of the peat carbon sink to be smaller than previous estimates, although sensitivity analysis shows that the primary productivity rather than fluvial carbon flux is a more important element in estimating the carbon budget in this regard.
Reverse engineering gene regulatory networks from measurement with missing values.
Ogundijo, Oyetunji E; Elmas, Abdulkadir; Wang, Xiaodong
2016-12-01
Gene expression time series data are usually in the form of high-dimensional arrays. Unfortunately, the data may sometimes contain missing values: for either the expression values of some genes at some time points or the entire expression values of a single time point or some sets of consecutive time points. This significantly affects the performance of many algorithms for gene expression analysis that take as an input, the complete matrix of gene expression measurement. For instance, previous works have shown that gene regulatory interactions can be estimated from the complete matrix of gene expression measurement. Yet, till date, few algorithms have been proposed for the inference of gene regulatory network from gene expression data with missing values. We describe a nonlinear dynamic stochastic model for the evolution of gene expression. The model captures the structural, dynamical, and the nonlinear natures of the underlying biomolecular systems. We present point-based Gaussian approximation (PBGA) filters for joint state and parameter estimation of the system with one-step or two-step missing measurements . The PBGA filters use Gaussian approximation and various quadrature rules, such as the unscented transform (UT), the third-degree cubature rule and the central difference rule for computing the related posteriors. The proposed algorithm is evaluated with satisfying results for synthetic networks, in silico networks released as a part of the DREAM project, and the real biological network, the in vivo reverse engineering and modeling assessment (IRMA) network of yeast Saccharomyces cerevisiae . PBGA filters are proposed to elucidate the underlying gene regulatory network (GRN) from time series gene expression data that contain missing values. In our state-space model, we proposed a measurement model that incorporates the effect of the missing data points into the sequential algorithm. This approach produces a better inference of the model parameters and hence, more accurate prediction of the underlying GRN compared to when using the conventional Gaussian approximation (GA) filters ignoring the missing data points.
NASA Technical Reports Server (NTRS)
Piskunov, Nikolai; Wood, Brian E.; Linsky, Jeffrey L.; Dempsey, Robert C.; Ayres, Thomas R.
1997-01-01
We analyze Goddard High-Resolution Spectrograph data to infer the properties of local interstellar gas and the Deuterium/Hydrogen (D/H) ratio for lines of sight toward four nearby late-type stars-HR 1099, 31 Comae, beta Ceti, and beta Cassiopeiae. The data consist of spectra of the hydrogen and deuterium Lyman-(alpha) lines, and echelle spectra of the Mg IIh and k lines toward all stars except beta Cas. Spectra of the RS CVn-type spectroscopic binary system HR 1099 were obtained near opposite quadratures to determine the intrinsic stellar emission line profile and the interstellar absorption separately. Multiple-velocity components were found toward HR 1099 and beta Cet. The spectra of 31 Com and beta Cet are particularly interesting because they sample lines of sight toward the north and south Galactic poles, respectively, for which H I and D I column densities were not previously available. The north Galactic pole appears to be a region of low hydrogen density like the 'interstellar tunnel' toward epsilon CMa. The temperature and turbulent velocities of the Local InterStellar Medium (LISM) that we measure for the lines of sight toward HR 1099, 31 Com, beta Cet, and beta Cas are similar to previously measured values (T approx.7000 K and xi = 1.0-1.6 km/s). The deuterium/hydrogen ratios found for these lines of sight are also consistent with previous measurements of other short lines of sight, which suggest D/H approx. 1.6 x 10(sup -5). In contrast, the Mg abundance measured for the beta Cet line of sight (implying a logarithmic depletion of D(Mg) = +0.30 +/- 0.15) is about 5 times larger than the Mg abundance previously observed toward alpha Cen, and about 20 times larger than all other previous measurements for the LISM. These results demonstrate that metal abundances in the LISM vary greatly over distances of only a few parsecs.
Indirect Determination of the Thermodynamic Temperature of a Gold Fixed-Point Cell
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2010-09-01
Since the value T 90(Au) was fixed on the ITS-90, some determinations of the thermodynamic temperature of the gold point have been performed which form, with other renormalized results of previous measurements by radiation thermometry, the basis for the current best estimates of ( T - T 90)Au = 39.9 mK as elaborated by the CCT-WG4. Such a value, even if consistent with the behavior of T - T 90 differences at lower temperatures, is quite influenced by the low values of T Au as determined with few radiometric measurements. At INRIM, an independent indirect determination of the thermodynamic temperature of gold was performed by means of a radiation thermometry approach. A fixed-point technique was used to realize approximated thermodynamic scales from the Zn point up to the Cu point. A Si-based standard radiation thermometer working at 900 nm and 950 nm was used. The low uncertainty presently associated to the thermodynamic temperature of fixed points and the accuracy of INRIM realizations, allowed scales with an uncertainty lower than 0.03 K in terms of the thermodynamic temperature to be realized. A fixed-point cell filled with gold, 99.999 % in purity, was measured, and its freezing temperature was determined by both interpolation and extrapolation. An average T Au = 1337.395 K was found with a combined standard uncertainty of 23 mK. Such a value is 25 mK higher than the presently available value as derived by the CCT-WG4 value of ( T - T 90)Au = 39.9 mK.
NASA Astrophysics Data System (ADS)
Vieira, D.; Teodoro, A.; Gomes, A.
2016-10-01
Land Surface Temperature (LST) is an important parameter related to land surface processes that changes continuously through time. Assessing its dynamics during a volcanic eruption has both environmental and socio-economical interest. Lava flows and other volcanic materials produced and deposited throughout an eruption transform the landscape, contributing to its heterogeneity and altering LST measurements. This paper aims to assess variations of satellite-derived LST and to detect patterns during the latest Fogo Island (Cape Verde) eruption, extending from November 2014 through February 2015. LST data was obtained through four processed Landsat 8 images, focused on the caldera where Pico do Fogo volcano sits. QGIS' plugin Semi-Automatic Classification was used in order to apply atmospheric corrections and radiometric calibrations. The algorithm used to retrieve LST values is a single-channel method, in which emissivity values are known. The absence of in situ measurements is compensated by the use of MODIS sensor-derived LST data, used to compare with Landsat retrieved measurements. LST data analysis shows as expected that the highest LST values are located inside the caldera. High temperature values were also founded on the south-facing flank of the caldera. Although spatial patterns observed on the retrieved data remained roughly the same during the time period considered, temperature values changed throughout the area and over time, as it was also expected. LST values followed the eruption dynamic experiencing a growth followed by a decline. Moreover, it seems possible to recognize areas affected by lava flows of previous eruptions, due to well-defined LST spatial patterns.
NASA Astrophysics Data System (ADS)
Li, Xiongwei; Wang, Zhe; Lui, Siu-Lung; Fu, Yangting; Li, Zheng; Liu, Jianming; Ni, Weidou
2013-10-01
A bottleneck of the wide commercial application of laser-induced breakdown spectroscopy (LIBS) technology is its relatively high measurement uncertainty. A partial least squares (PLS) based normalization method was proposed to improve pulse-to-pulse measurement precision for LIBS based on our previous spectrum standardization method. The proposed model utilized multi-line spectral information of the measured element and characterized the signal fluctuations due to the variation of plasma characteristic parameters (plasma temperature, electron number density, and total number density) for signal uncertainty reduction. The model was validated by the application of copper concentration prediction in 29 brass alloy samples. The results demonstrated an improvement on both measurement precision and accuracy over the generally applied normalization as well as our previously proposed simplified spectrum standardization method. The average relative standard deviation (RSD), average of the standard error (error bar), the coefficient of determination (R2), the root-mean-square error of prediction (RMSEP), and average value of the maximum relative error (MRE) were 1.80%, 0.23%, 0.992, 1.30%, and 5.23%, respectively, while those for the generally applied spectral area normalization were 3.72%, 0.71%, 0.973, 1.98%, and 14.92%, respectively.
Steyerberg, Ewout W; Vedder, Moniek M; Leening, Maarten J G; Postmus, Douwe; D'Agostino, Ralph B; Van Calster, Ben; Pencina, Michael J
2015-07-01
New markers may improve prediction of diagnostic and prognostic outcomes. We aimed to review options for graphical display and summary measures to assess the predictive value of markers over standard, readily available predictors. We illustrated various approaches using previously published data on 3264 participants from the Framingham Heart Study, where 183 developed coronary heart disease (10-year risk 5.6%). We considered performance measures for the incremental value of adding HDL cholesterol to a prediction model. An initial assessment may consider statistical significance (HR = 0.65, 95% confidence interval 0.53 to 0.80; likelihood ratio p < 0.001), and distributions of predicted risks (densities or box plots) with various summary measures. A range of decision thresholds is considered in predictiveness and receiver operating characteristic curves, where the area under the curve (AUC) increased from 0.762 to 0.774 by adding HDL. We can furthermore focus on reclassification of participants with and without an event in a reclassification graph, with the continuous net reclassification improvement (NRI) as a summary measure. When we focus on one particular decision threshold, the changes in sensitivity and specificity are central. We propose a net reclassification risk graph, which allows us to focus on the number of reclassified persons and their event rates. Summary measures include the binary AUC, the two-category NRI, and decision analytic variants such as the net benefit (NB). Various graphs and summary measures can be used to assess the incremental predictive value of a marker. Important insights for impact on decision making are provided by a simple graph for the net reclassification risk. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Trzaska, W. H.; Knyazheva, G. N.; Perkowski, J.; Andrzejewski, J.; Khlebnikov, S. V.; Kozulin, E. M.; Malkiewicz, T.; Mutterer, M.; Savelieva, E. O.
2018-03-01
New experimental data on energy loss of 4He, 16O, 40Ar, 48Ca and 84Kr ions in thin, self-supporting foils of C, Al, Ni, Ag, Lu, Au, Pb and Th are presented. The measurements, using the TOF-E method, were done in a very broad energy range around the stopping power maximum; typically from 0.1 to 11 MeV/u. When available, the extracted stopping power values are compared with the previously published data. The overall agreement is good although a fair comparison is difficult as the covered energy range is much larger than in previous measurements. The small error bars and a broad coverage allowed us to test the predictions of theoretical codes: PASS, CasP, and semi-empirical programs: SRIM, LET, MSTAR, and the Hubert table predictions. The deviations of PASS predictions from the experimental data do not exceed 20% for all the measured combinations. CasP predictions are within 15% from the data for heavier ions but diverge up to 40% for lighter ions. Semi-empirical approaches, including SRIM, deviate from the experimental data by less than 5% for the regions already covered by previous experiments but err by about 10-20% for the ion/target combinations that were not measured before: Ca in Lu as well as Kr in Lu, Pb, and Th.
The Absolute Abundance of Iron in the Solar Corona.
White; Thomas; Brosius; Kundu
2000-05-10
We present a measurement of the abundance of Fe relative to H in the solar corona using a technique that differs from previous spectroscopic and solar wind measurements. Our method combines EUV line data from the Coronal Diagnostic Spectrometer (CDS) on the Solar and Heliospheric Observatory with thermal bremsstrahlung radio data from the VLA. The coronal Fe abundance is derived by equating the thermal bremsstrahlung radio emission calculated from the EUV Fe line data to that observed with the VLA, treating the Fe/H abundance as the sole unknown. We apply this technique to a compact cool active region and find Fe&solm0;H=1.56x10-4, or about 4 times its value in the solar photosphere. Uncertainties in the CDS radiometric calibration, the VLA intensity measurements, the atomic parameters, and the assumptions made in the spectral analysis yield net uncertainties of approximately 20%. This result implies that low first ionization potential elements such as Fe are enhanced in the solar corona relative to photospheric values.
Kirsch, Leo Edward; Devlin, Matthew James; Mosby, Shea Morgan; ...
2017-09-01
We present a new measurement of the 6Li(n,α)t cross section from 245 keV to 10 MeV using a 252Cf fission chamber with 6LiI(Eu) and Cs 2LiYCl 6:Ce (CLYC) scintillators which act as both target and detector. Neutron energies are determined from the time of flight (TOF) method using the signals from spontaneous fission and reaction product recoil. Simulations of neutron downscatter in the crystals and fission chamber bring 6Li(n,α)t cross section values measured with the 6LiI(Eu) into agreement with previous experiments and evaluations, except for two resonances at 4.2 and 6.5 MeV introduced by ENDF/B-VII.1. Suspected neutron transport modeling issuesmore » cause the cross section values obtained with CLYC to be discrepant above 2 MeV.« less
Experimental study of influence characteristics of flue gas fly ash on acid dew point
NASA Astrophysics Data System (ADS)
Song, Jinhui; Li, Jiahu; Wang, Shuai; Yuan, Hui; Ren, Zhongqiang
2017-12-01
The long-term operation experience of a large number of utility boilers shows that the measured value of acid dew point is generally lower than estimated value. This is because the influence of CaO and MgO on acid dew point in flue gas fly ash is not considered in the estimation formula of acid dew point. On the basis of previous studies, the experimental device for acid dew point measurement was designed and constructed, and the acid dew point under different smoke conditions was measured. The results show that the CaO and MgO in the flue gas fly ash have an obvious influence on the acid dew point, and the content of the fly ash is negatively correlated with the temperature of acid dew point At the same time, the concentration of H2SO4 in flue gas is different, and the acid dew point of flue gas is different, and positively correlated with the acid dew point.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maulina, Hervin; Santoso, Iman, E-mail: iman.santoso@ugm.ac.id; Subama, Emmistasega
2016-04-19
The extraction of the dielectric constant of nanostructured graphene on SiC substrates from spectroscopy ellipsometry measurement using the Gauss-Newton inversion (GNI) method has been done. This study aims to calculate the dielectric constant and refractive index of graphene by extracting the value of ψ and Δ from the spectroscopy ellipsometry measurement using GNI method and comparing them with previous result which was extracted using Drude-Lorentz (DL) model. The results show that GNI method can be used to calculate the dielectric constant and refractive index of nanostructured graphene on SiC substratesmore faster as compared to DL model. Moreover, the imaginary partmore » of the dielectric constant values and coefficient of extinction drastically increases at 4.5 eV similar to that of extracted using known DL fitting. The increase is known due to the process of interband transition and the interaction between the electrons and electron-hole at M-points in the Brillouin zone of graphene.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirsch, Leo Edward; Devlin, Matthew James; Mosby, Shea Morgan
We present a new measurement of the 6Li(n,α)t cross section from 245 keV to 10 MeV using a 252Cf fission chamber with 6LiI(Eu) and Cs 2LiYCl 6:Ce (CLYC) scintillators which act as both target and detector. Neutron energies are determined from the time of flight (TOF) method using the signals from spontaneous fission and reaction product recoil. Simulations of neutron downscatter in the crystals and fission chamber bring 6Li(n,α)t cross section values measured with the 6LiI(Eu) into agreement with previous experiments and evaluations, except for two resonances at 4.2 and 6.5 MeV introduced by ENDF/B-VII.1. Suspected neutron transport modeling issuesmore » cause the cross section values obtained with CLYC to be discrepant above 2 MeV.« less
Gomar, Jesus J; Conejero-Goldberg, Concepcion; Davies, Peter; Goldberg, Terry E
2014-01-01
Background This study examined the predictive value of different classes of markers in the progression from Mild Cognitive Impairment (MCI) to Alzheimer’s disease (AD) over an extended 4 year follow-up in ADNI. Methods MCI patients assessed on clinical, cognitive, MRI, PET-FDG, and CSF markers at baseline, and followed on a yearly basis for four years to ascertain progression to AD. Logistic regression models were fitted in clusters including demographics, APOE genotype, cognitive markers, and biomarkers (morphometric, PET-FDG, CSF Abeta and tau). Results The predictive model at four years revealed that two cognitive measures, an episodic memory measure and a clock drawing screening test, were the best predictors of conversion (AUC= 0.78). Conclusions This model of prediction is consistent to the previous model at two years, thus highlighting the importance of cognitive measures in progression from MCI to AD. Cognitive markers were more robust predictors than biomarkers. PMID:24613706
Friction losses in a lubricated thrust-loaded cageless angular-contract bearing
NASA Technical Reports Server (NTRS)
Townsend, D. P.; Allen, C. W.; Zaretsky, E. V.
1973-01-01
The NASA spinning torque apparatus was modified to measure the spinning torque on a cageless ball thrust bearing. Friction torque was measured for thrust loads varying from 44.5 to 403 newtons (10 to 90 lb) at speeds of 1000, 2000, and 3000 rpm. Tests were conducted with di-2-ethylhexyl sebacate and a synthetic paraffinic oil. These tests were run with either oil jet lubrication or with a thin surface film of lubricant only. An analytical model which included rolling resistance was developed and extended from previous models for spinning torque and lubricant rheology. The model was extended by the inclusion of rolling resistance. The computed values were in fair agreement with the experimental results and confirmed previous hypotheses that a thin lubricant film gives minimum bearing torque and an oil jet flow of a viscous lubricant will result in considerable rolling torque in addition to the torque due to ball spin.
Exchange-mediated spin-lattice relaxation of Fe3+ ions in borate glasses.
Misra, Sushil K; Pilbrow, John R
2007-03-01
Spin-lattice relaxation times (T1) of two borate glasses doped with different concentrations of Fe2O3 were measured using the Electron Spin-Echo (ESE) technique at X-band (9.630 GHz) in the temperature range 2-6K. In comparison with a previous investigation of Fe3+-doped silicate glasses, the relaxation rates were comparable and differed by no more than a factor of two. The data presented here extend those previously reported for borate glasses in the 10-250K range but measured using the amplitude-modulation technique. The T1 values were found to depend on temperature (T) as T(n) with n approximately 1 for the 1% and 0.1% Fe2O3-doped glass samples. These results are consistent with spin-lattice relaxation as effected by exchange interaction of a Fe3+ spin exchange-coupled to another Fe3+ spin in an amorphous material.
Lisowska, A; Knapp, M; Tycinska, A; Sawicki, R; Kralisz, P; Lisowski, P; Sobkowicz, B; Musial, W I
2014-02-01
Contrast-enhanced ultrasound imaging of the carotid arteries (CECU) permits direct, real-time visualization of neovascularization in atherosclerotic plaques and is a confirmed predictor of unstable atheromatous lesions. The aim of the study was the assessment of a new, automatically measured index of intensity in quantitative estimation of the contrast flow through the carotid plaque (till now assessed only visually). Forty-four patients (mean age 70.4±11.4) with ultrasound diagnosed significant stenosis of internal carotid artery (ICA), after cerebrovascular or cardiovascular events, qualified for carotid artery stenting (CAS) were examined. The carotid ultrasound examinations with contrast agent Sonovue were performed. Visually in 22 patients (50%) contrast flow through the atherosclerotic plaques was found. In 17 patients (38.6%) massive, calcified atherosclerotic plaques were present. Patients with preserved contrast flow through the plaque more frequently had a history of cerebral stroke (P=0.04). Massive calcifications of atherosclerotic plaques correlated with a previous MI (P=0.03) and the degree of advancement of coronary artery disease (P=0.04), but not with a previous cerebral stroke. Contrast flow through the atherosclerotic plaque positively correlated with values of the index of intensity (r=0.69, P<0.00001). In patients with preserved contrast flow the mean value of the index of intensity was 22.24±3.55 dB as compared with 12.37±7.67 dB - a value present in patients without preserved contrast flow. No significant relation for the degree of calcifications and the value of the index of intensity was found. The assessment of the index of intensity is a novel, simple and automatic method to estimate the degree of contrast flow through the carotid plaque. The values of the index of intensity correlate with the contrast flow through the atherosclerotic plaque, but not with its calcification.
A Permeability Study of O2 and the Trace Amine p-Tyramine through Model Phosphatidylcholine Bilayers
Holland, Bryan W.; Berry, Mark D.; Gray, C. G.; Tomberli, Bruno
2015-01-01
We study here the permeability of the hydrophobic O2 molecule through a model DPPC bilayer at 323K and 350K, and of the trace amine p-tyramine through PC bilayers at 310K. The tyramine results are compared to previous experimental work at 298K. Nonequilibrium work methods were used in conjunction to simultaneously obtain both the potential of mean force (PMF) and the position dependent transmembrane diffusion coefficient, D(z), from the simulations. These in turn were used to calculate the permeability coefficient, P, through the inhomogeneous solubility-diffusion model. The results for O2 are consistent with previous simulations, and agree with experimentally measured P values for PC bilayers. A temperature dependence in the permeability of O2 through DPPC was obtained, with P decreasing at higher temperatures. Two relevant species of p-tyramine were simulated, from which the PMF and D(z) were calculated. The charged species had a large energetic barrier to crossing the bilayer of ~ 21 kcal/mol, while the uncharged, deprotonated species had a much lower barrier of ~ 7 kcal/mol. The effective in silico permeability for p-tyramine was calculated by applying three approximations, all of which gave nearly identical results (presented here as a function of the pKa). As the permeability value calculated from simulation was highly dependent on the pKa of the amine group, a further pKa study was performed that also varied the fraction of the uncharged and zwitterionic p-tyramine species. Using the experimental P value together with the simulated results, we were able to label the phenolic group as responsible for the pKa1 and the amine for the pKa2, that together represent all of the experimentally measured pKa values for p-tyramine. This agrees with older experimental results, in contrast to more recent work that has suggested there is a strong ambiguity in the pKa values. PMID:26086933
Abe, Y.; Appel, S.; Abrahão, T.; ...
2016-01-27
We observed a measurement of the Double Chooz collaboration and the neutrino mixing angle θ 13 using reactormore » $$\\bar{v}$$ e via the inverse beta decay reaction in which the neutron is captured on hydrogen. Our measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050 m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. Furthermore, these improvements demonstrate the capability of precise measurement of reactor $$\\bar{v}$$ e without gadolinium loading. Spectral distortions from the $$\\bar{v}$$ e reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of sin 2 2θ 13= 0.095 0.039 +0.038 (stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of sin 2 2θ 13 = 0.088 ± 0.033(stat+syst).« less
Dimensionless number is central to stress relaxation and expansive growth of the cell wall.
Ortega, Joseph K E
2017-06-07
Experiments demonstrate that both plastic and elastic deformation of the cell wall are necessary for wall stress relaxation and expansive growth of walled cells. A biophysical equation (Augmented Growth Equation) was previously shown to accurately model the experimentally observed wall stress relaxation and expansive growth rate. Here, dimensional analysis is used to obtain a dimensionless Augmented Growth Equation with dimensionless coefficients (groups of variables, or Π parameters). It is shown that a single Π parameter controls the wall stress relaxation rate. The Π parameter represents the ratio of plastic and elastic deformation rates, and provides an explicit relationship between expansive growth rate and the wall's mechanical properties. Values for Π are calculated for plant, algal, and fungal cells from previously reported experimental results. It is found that the Π values for each cell species are large and very different from each other. Expansive growth rates are calculated using the calculated Π values and are compared to those measured for plant and fungal cells during different growth conditions, after treatment with IAA, and in different developmental stages. The comparison shows good agreement and supports the claim that the Π parameter is central to expansive growth rate of walled cells.
Investigation of the Air Quality Change Effect on Gnss Signals
NASA Astrophysics Data System (ADS)
Gurbuz, G.; Gormus, K. S.; Altan, U.
2017-11-01
Air pollution is the most important environmental problem in Zonguldak city center. Since bituminous coal is used for domestic heating in houses and generating electricity in thermal power plants, particulate matter (PM10) is the leading air pollutant. Previous studies have shown that the water vapor in the troposphere is responsible for the tropospheric zenith delay in Global Navigation Satellite System (GNSS) measurements. In this study, data obtained from the ZONG GNSS station from Türkiye Ulusal Sabit GNSS Ağı (TUSAGA-Active network) in the central district of Zonguldak province, processed with GIPSY-OASIS II and GAMIT/GlobK software using the VMF1 mapping function, which is developed previously and considered to be the most accurate model. The resulting values were examined separately in terms of software. The meteorological parameters obtained from the Turkish State Meteorological Service and the air pollution values obtained from the Ministry of Environment and Urban Planning were analyzed and the zenith delay values were compared. When wet zenith delays of different days with different amounts of PM10 concentrations were examined in succession and under the same meteorological conditions, differences in the range of 20-40 mm on ZTD were observed.
NASA Technical Reports Server (NTRS)
Mumma, M. J.; Misakian, M.; Jackson, W. M.; Faris, J. L.
1973-01-01
Angular intensity distributions of helium (n 1P - 1 1S) resonance photons with respect to the exciting electron beam are presented. The angular intensity distributions were measured at selected electron impact energies from 25 eV (near threshold) to 150 eV. Polarization fractions (Pi) were obtained by analyzing the data in terms of the theoretical relation between angular intensity distribution and Pi, i.e. Iota (theta) = Iota (90) (1 - Pi sq cos theta). The experimental values for Pi are compared with recent theoretical results and with previous experimental values for the (3 1P - 2 1S) transition.
Reid, Clare L
2007-10-01
A wide variation in 24h energy expenditure has been demonstrated previously in intensive care unit (ICU) patients. The accuracy of equations used to predict energy expenditure in critically ill patients is frequently compared with single or short-duration indirect calorimetry measurements, which may not represent the total energy expenditure (TEE) of these patients. To take into account this variability in energy expenditure, estimates have been compared with continuous indirect calorimetry measurements. Continuous (24h/day for 5 days) indirect calorimetry measurements were made in patients requiring mechanical ventilation for 5 days. The Harris-Benedict, Schofield and Ireton-Jones equations and the American College of Chest Physicians recommendation of 25 kcal/kg/day were used to estimate energy requirements. A total of 192 days of measurements, in 27 patients, were available for comparison with the different equations. Agreement between the equations and measured values was poor. The Harris-Benedict, Schofield and ACCP equations provided more estimates (66%, 66% and 65%, respectively) within 80% and 110% of TEE values. However, each of these equations would have resulted in clinically significant underfeeding (<80% of TEE) in 16%, 15% and 22% of patients, respectively, and overfeeding (>110% of TEE) in 18%, 19% and 13% of patients, respectively. Limits of agreement between the different equations and TEE values were unacceptably wide. Prediction equations may result in significant under or overfeeding in the clinical setting.
Precision spectroscopy of the 2S-4P transition in atomic hydrogen
NASA Astrophysics Data System (ADS)
Maisenbacher, Lothar; Beyer, Axel; Matveev, Arthur; Grinin, Alexey; Pohl, Randolf; Khabarova, Ksenia; Kolachevsky, Nikolai; Hänsch, Theodor W.; Udem, Thomas
2017-04-01
Precision measurements of atomic hydrogen have long been successfully used to extract fundamental constants and to test bound-state QED. However, both these applications are limited by measurements of hydrogen lines other than the very precisely known 1S-2S transition. Moreover, the proton r.m.s.charge radius rp extracted from electronic hydrogen measurements currently disagrees by 4 σ with the much more precise value extracted from muonic hydrogen spectroscopy. We have measured the 2S-4P transition in atomic hydrogen using a cryogenic beam of hydrogen atoms optically excited to the initial 2S state. The first order Doppler shift of the one-photon 2S-4P transition is suppressed by actively stabilized counter-propagating laser beams and time-of-flight resolved detection. Quantum interference between excitation paths can lead to significant line distortions in our system. We use an experimentally verified, simple line shape model to take these distortions into account. With this, we can extract a new value for rp and the Rydberg constant R∞ with comparable accuracy as the combined previous H world data.
Augmentation of oxygen transport by various hemoglobins as determined by pulsed field gradient NMR.
Budhiraja, Vikas; Hellums, J David; Post, Jan F M
2002-11-01
Diffusion of oxyhemoglobin has been shown to augment the oxygen transport inside the red blood cells. Measurement of hemoglobin diffusion coefficients by pulsed-field gradient (PFG) nuclear magnetic resonance (NMR) technique can be used for estimating this augmentation effect. Self-diffusion coefficients of polymerized and unpolymerized bovine hemoglobin (Hb) and several other proteins were measured using this technique. The Hb diffusion coefficient was used to determine the effective permeability of oxygen and augmentation of oxygen transport through samples of Hb solutions due to diffusion of oxyhemoglobin. The values compared well with our previous diffusion cell measurements of effective diffusivity and augmentation. Our NMR studies show that even at low concentrations the augmentation of oxygen transport due to diffusion can be significant. The PFG NMR technique can thus provide an accurate and easy method for measuring augmentation of oxygen transport, especially in dilute samples of Hb. The results on polyhemoglobin and high-molecular-weight hemoglobin are of both basic interest and practical value in assessing the promise and performance of hemoglobin-based blood substitutes.
Thomas, David L; Lythgoe, Mark F; Gadian, David G; Ordidge, Roger J
2006-04-01
A novel method for measuring the longitudinal relaxation time of arterial blood (T1a) is presented. Knowledge of T1a is essential for accurately quantifying cerebral perfusion using arterial spin labeling (ASL) techniques. The method is based on the flow-sensitive alternating inversion recovery (FAIR) pulsed ASL (PASL) approach. We modified the standard FAIR acquisition scheme by incorporating a global saturation pulse at the beginning of the recovery period. With this approach the FAIR tissue signal difference has a simple monoexponential dependence on the recovery time, with T1a as the time constant. Therefore, FAIR measurements performed over a range of recovery times can be fitted to a monoexponential recovery curve and T1a can be calculated directly. This eliminates many of the difficulties associated with the measurement of T1a. Experiments performed in vivo in the mouse at 2.35T produced a mean value of 1.51 s for T1a, consistent with previously published values. (c) 2006 Wiley-Liss, Inc.
Lehmann, Thomas; Redies, Christoph
2017-01-01
For centuries, oil paintings have been a major segment of the visual arts. The JenAesthetics data set consists of a large number of high-quality images of oil paintings of Western provenance from different art periods. With this database, we studied the relationship between objective image measures and subjective evaluations of the images, especially evaluations on aesthetics (defined as artistic value) and beauty (defined as individual liking). The objective measures represented low-level statistical image properties that have been associated with aesthetic value in previous research. Subjective rating scores on aesthetics and beauty correlated not only with each other but also with different combinations of the objective measures. Furthermore, we found that paintings from different art periods vary with regard to the objective measures, that is, they exhibit specific patterns of statistical image properties. In addition, clusters of participants preferred different combinations of these properties. In conclusion, the results of the present study provide evidence that statistical image properties vary between art periods and subject matters and, in addition, they correlate with the subjective evaluation of paintings by the participants. PMID:28694958
Duval, Jérôme F L; Slaveykova, Vera I; Hosse, Monika; Buffle, Jacques; Wilkinson, Kevin J
2006-10-01
The electrostatic, hydrodynamic and conformational properties of aqueous solutions of succinoglycan have been analyzed by fluorescence correlation spectroscopy (FCS), proton titration, and capillary electrophoresis (CE) over a large range of pH values and electrolyte (NaCl) concentrations. Using the theoretical formalism developed previously for the electrokinetic properties of soft, permeable particles, a quantitative analysis for the electro-hydrodynamics of succinoglycan is performed by taking into account, in a self-consistent manner, the measured values of the diffusion coefficients, electric charge densities, and electrophoretic mobilities. For that purpose, two limiting conformations for the polysaccharide in solution are tested, i.e. succinoglycan behaves as (i) a spherical, random coil polymer or (ii) a rodlike particle with charged lateral chains. The results show that satisfactory modeling of the titration data for ionic strengths larger than 50 mM can be accomplished using both geometries over the entire range of pH values. Electrophoretic mobilities measured for sufficiently large pH values (pH > 5-6) are in line with predictions based on either model. The best manner to discriminate between these two conceptual models is briefly discussed. For low pH values (pH < 5), both models indicate aggregation, resulting in an increase of the hydrodynamic permeability and a decrease of the diffusion coefficient.
Sadaie, Wakako; Harada, Yoshie; Matsuda, Michiyuki
2014-01-01
Computer-assisted simulation is a promising approach for clarifying complicated signaling networks. However, this approach is currently limited by a deficiency of kinetic parameters determined in living cells. To overcome this problem, we applied fluorescence cross-correlation spectrometry (FCCS) to measure dissociation constant (Kd) values of signaling molecule complexes in living cells (in vivo Kd). Among the pairs of fluorescent molecules tested, that of monomerized enhanced green fluorescent protein (mEGFP) and HaloTag-tetramethylrhodamine was most suitable for the measurement of in vivo Kd by FCCS. Using this pair, we determined 22 in vivo Kd values of signaling molecule complexes comprising the epidermal growth factor receptor (EGFR)–Ras–extracellular signal-regulated kinase (ERK) mitogen-activated protein (MAP) kinase pathway. With these parameters, we developed a kinetic simulation model of the EGFR-Ras-ERK MAP kinase pathway and uncovered a potential role played by stoichiometry in Shc binding to EGFR during the peak activations of Ras, MEK, and ERK. Intriguingly, most of the in vivo Kd values determined in this study were higher than the in vitro Kd values reported previously, suggesting the significance of competitive bindings inside cells. These in vivo Kd values will provide a sound basis for the quantitative understanding of signal transduction. PMID:24958104