Sample records for values standard deviations

  1. Estimate of standard deviation for a log-transformed variable using arithmetic means and standard deviations.

    PubMed

    Quan, Hui; Zhang, Ji

    2003-09-15

    Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.

  2. Exploring Students' Conceptions of the Standard Deviation

    ERIC Educational Resources Information Center

    delMas, Robert; Liu, Yan

    2005-01-01

    This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…

  3. Estimating extreme stream temperatures by the standard deviate method

    NASA Astrophysics Data System (ADS)

    Bogan, Travis; Othmer, Jonathan; Mohseni, Omid; Stefan, Heinz

    2006-02-01

    It is now widely accepted that global climate warming is taking place on the earth. Among many other effects, a rise in air temperatures is expected to increase stream temperatures indefinitely. However, due to evaporative cooling, stream temperatures do not increase linearly with increasing air temperatures indefinitely. Within the anticipated bounds of climate warming, extreme stream temperatures may therefore not rise substantially. With this concept in mind, past extreme temperatures measured at 720 USGS stream gauging stations were analyzed by the standard deviate method. In this method the highest stream temperatures are expressed as the mean temperature of a measured partial maximum stream temperature series plus its standard deviation multiplied by a factor KE (standard deviate). Various KE-values were explored; values of KE larger than 8 were found physically unreasonable. It is concluded that the value of KE should be in the range from 7 to 8. A unit error in estimating KE translates into a typical stream temperature error of about 0.5 °C. Using a logistic model for the stream temperature/air temperature relationship, a one degree error in air temperature gives a typical error of 0.16 °C in stream temperature. With a projected error in the enveloping standard deviate dKE=1.0 (range 0.5-1.5) and an error in projected high air temperature d Ta=2 °C (range 0-4 °C), the total projected stream temperature error is estimated as d Ts=0.8 °C.

  4. The Standard Deviation of Launch Vehicle Environments

    NASA Technical Reports Server (NTRS)

    Yunis, Isam

    2005-01-01

    Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.

  5. Standard deviation index for stimulated Brillouin scattering suppression with different homogeneities.

    PubMed

    Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-10

    We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.

  6. Reducing the standard deviation in multiple-assay experiments where the variation matters but the absolute value does not.

    PubMed

    Echenique-Robba, Pablo; Nelo-Bazán, María Alejandra; Carrodeguas, José A

    2013-01-01

    When the value of a quantity x for a number of systems (cells, molecules, people, chunks of metal, DNA vectors, so on) is measured and the aim is to replicate the whole set again for different trials or assays, despite the efforts for a near-equal design, scientists might often obtain quite different measurements. As a consequence, some systems' averages present standard deviations that are too large to render statistically significant results. This work presents a novel correction method of a very low mathematical and numerical complexity that can reduce the standard deviation of such results and increase their statistical significance. Two conditions are to be met: the inter-system variations of x matter while its absolute value does not, and a similar tendency in the values of x must be present in the different assays (or in other words, the results corresponding to different assays must present a high linear correlation). We demonstrate the improvements this method offers with a cell biology experiment, but it can definitely be applied to any problem that conforms to the described structure and requirements and in any quantitative scientific field that deals with data subject to uncertainty.

  7. Visualizing the Sample Standard Deviation

    ERIC Educational Resources Information Center

    Sarkar, Jyotirmoy; Rashid, Mamunur

    2017-01-01

    The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…

  8. Comparing Standard Deviation Effects across Contexts

    ERIC Educational Resources Information Center

    Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.

    2017-01-01

    Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…

  9. 7 CFR 400.204 - Notification of deviation from standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...

  10. A Note on Standard Deviation and Standard Error

    ERIC Educational Resources Information Center

    Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth

    2010-01-01

    Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.

  11. Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.

    PubMed

    McClure, Foster D; Lee, Jung K

    2006-01-01

    A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.

  12. Role of the standard deviation in the estimation of benchmark doses with continuous data.

    PubMed

    Gaylor, David W; Slikker, William

    2004-12-01

    For continuous data, risk is defined here as the proportion of animals with values above a large percentile, e.g., the 99th percentile or below the 1st percentile, for the distribution of values among control animals. It is known that reducing the standard deviation of measurements through improved experimental techniques will result in less stringent (higher) doses for the lower confidence limit on the benchmark dose that is estimated to produce a specified risk of animals with abnormal levels for a biological effect. Thus, a somewhat larger (less stringent) lower confidence limit is obtained that may be used as a point of departure for low-dose risk assessment. It is shown in this article that it is important for the benchmark dose to be based primarily on the standard deviation among animals, s(a), apart from the standard deviation of measurement errors, s(m), within animals. If the benchmark dose is incorrectly based on the overall standard deviation among average values for animals, which includes measurement error variation, the benchmark dose will be overestimated and the risk will be underestimated. The bias increases as s(m) increases relative to s(a). The bias is relatively small if s(m) is less than one-third of s(a), a condition achieved in most experimental designs.

  13. A Visual Model for the Variance and Standard Deviation

    ERIC Educational Resources Information Center

    Orris, J. B.

    2011-01-01

    This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.

  14. 7 CFR 400.174 - Notification of deviation from financial standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...

  15. Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling

    NASA Astrophysics Data System (ADS)

    Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.

    2008-05-01

    We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.

  16. Size-dependent standard deviation for growth rates: empirical results and theoretical modeling.

    PubMed

    Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H Eugene; Grosse, I

    2008-05-01

    We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation sigma(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation sigma(R) on the average value of the wages with a scaling exponent beta approximately 0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation sigma(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of sigma(R) on the average payroll with a scaling exponent beta approximately -0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.

  17. Standard Deviation for Small Samples

    ERIC Educational Resources Information Center

    Joarder, Anwar H.; Latif, Raja M.

    2006-01-01

    Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…

  18. Age-independent anti-Müllerian hormone (AMH) standard deviation scores to estimate ovarian function.

    PubMed

    Helden, Josef van; Weiskirchen, Ralf

    2017-06-01

    To determine single year age-specific anti-Müllerian hormone (AMH) standard deviation scores (SDS) for women associated to normal ovarian function and different ovarian disorders resulting in sub- or infertility. Determination of particular year median and mean AMH values with standard deviations (SD), calculation of age-independent cut off SDS for the discrimination between normal ovarian function and ovarian disorders. Single-year-specific median, mean, and SD values have been evaluated for the Beckman Access AMH immunoassay. While the decrease of both median and mean AMH values is strongly correlated with increasing age, calculated SDS values have been shown to be age independent with the differentiation between normal ovarian function measured as occurred ovulation with sufficient luteal activity compared with hyperandrogenemic cycle disorders or anovulation associated with high AMH values and reduced ovarian activity or insufficiency associated with low AMH, respectively. These results will be helpful for the treatment of patients and the ventilation of the different reproductive options. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The truly remarkable universality of half a standard deviation: confirmation through another look.

    PubMed

    Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W

    2004-10-01

    In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.

  20. Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation

    ERIC Educational Resources Information Center

    Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann

    2017-01-01

    This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…

  1. A better norm-referenced grading using the standard deviation criterion.

    PubMed

    Chan, Wing-shing

    2014-01-01

    The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.

  2. Dynamics of the standard deviations of three wind velocity components from the data of acoustic sounding

    NASA Astrophysics Data System (ADS)

    Krasnenko, N. P.; Kapegesheva, O. F.; Shamanaeva, L. G.

    2017-11-01

    Spatiotemporal dynamics of the standard deviations of three wind velocity components measured with a mini-sodar in the atmospheric boundary layer is analyzed. During the day on September 16 and at night on September 12 values of the standard deviation changed for the x- and y-components from 0.5 to 4 m/s, and for the z-component from 0.2 to 1.2 m/s. An analysis of the vertical profiles of the standard deviations of three wind velocity components for a 6-day measurement period has shown that the increase of σx and σy with altitude is well described by a power law dependence with exponent changing from 0.22 to 1.3 depending on the time of day, and σz depends linearly on the altitude. The approximation constants have been found and their errors have been estimated. The established physical regularities and the approximation constants allow the spatiotemporal dynamics of the standard deviation of three wind velocity components in the atmospheric boundary layer to be described and can be recommended for application in ABL models.

  3. Does standard deviation matter? Using "standard deviation" to quantify security of multistage testing.

    PubMed

    Wang, Chun; Zheng, Yi; Chang, Hua-Hua

    2014-01-01

    With the advent of web-based technology, online testing is becoming a mainstream mode in large-scale educational assessments. Most online tests are administered continuously in a testing window, which may post test security problems because examinees who take the test earlier may share information with those who take the test later. Researchers have proposed various statistical indices to assess the test security, and one most often used index is the average test-overlap rate, which was further generalized to the item pooling index (Chang & Zhang, 2002, 2003). These indices, however, are all defined as the means (that is, the expected proportion of common items among examinees) and they were originally proposed for computerized adaptive testing (CAT). Recently, multistage testing (MST) has become a popular alternative to CAT. The unique features of MST make it important to report not only the mean, but also the standard deviation (SD) of test overlap rate, as we advocate in this paper. The standard deviation of test overlap rate adds important information to the test security profile, because for the same mean, a large SD reflects that certain groups of examinees share more common items than other groups. In this study, we analytically derived the lower bounds of the SD under MST, with the results under CAT as a benchmark. It is shown that when the mean overlap rate is the same between MST and CAT, the SD of test overlap tends to be larger in MST. A simulation study was conducted to provide empirical evidence. We also compared the security of MST under the single-pool versus the multiple-pool designs; both analytical and simulation studies show that the non-overlapping multiple-pool design will slightly increase the security risk.

  4. Precision analysis for standard deviation measurements of immobile single fluorescent molecule images.

    PubMed

    DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M

    2010-03-29

    Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.

  5. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range.

    PubMed

    Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun

    2014-12-19

    In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different

  6. 1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...

  7. SU-E-I-59: Investigation of the Usefulness of a Standard Deviation and Mammary Gland Density as Indexes for Mammogram Classification.

    PubMed

    Takarabe, S; Yabuuchi, H; Morishita, J

    2012-06-01

    To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.

  8. Quantitative angle-insensitive flow measurement using relative standard deviation OCT

    NASA Astrophysics Data System (ADS)

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-01

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo.

  9. Quantitative angle-insensitive flow measurement using relative standard deviation OCT.

    PubMed

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-30

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .

  10. Wavelength selection method with standard deviation: application to pulse oximetry.

    PubMed

    Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija

    2011-07-01

    Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.

  11. Standard deviation and standard error of the mean.

    PubMed

    Lee, Dong Kyu; In, Junyong; Lee, Sangseok

    2015-06-01

    In most clinical and experimental studies, the standard deviation (SD) and the estimated standard error of the mean (SEM) are used to present the characteristics of sample data and to explain statistical analysis results. However, some authors occasionally muddle the distinctive usage between the SD and SEM in medical literature. Because the process of calculating the SD and SEM includes different statistical inferences, each of them has its own meaning. SD is the dispersion of data in a normal distribution. In other words, SD indicates how accurately the mean represents sample data. However the meaning of SEM includes statistical inference based on the sampling distribution. SEM is the SD of the theoretical distribution of the sample means (the sampling distribution). While either SD or SEM can be applied to describe data and statistical results, one should be aware of reasonable methods with which to use SD and SEM. We aim to elucidate the distinctions between SD and SEM and to provide proper usage guidelines for both, which summarize data and describe statistical results.

  12. Standard deviation and standard error of the mean

    PubMed Central

    In, Junyong; Lee, Sangseok

    2015-01-01

    In most clinical and experimental studies, the standard deviation (SD) and the estimated standard error of the mean (SEM) are used to present the characteristics of sample data and to explain statistical analysis results. However, some authors occasionally muddle the distinctive usage between the SD and SEM in medical literature. Because the process of calculating the SD and SEM includes different statistical inferences, each of them has its own meaning. SD is the dispersion of data in a normal distribution. In other words, SD indicates how accurately the mean represents sample data. However the meaning of SEM includes statistical inference based on the sampling distribution. SEM is the SD of the theoretical distribution of the sample means (the sampling distribution). While either SD or SEM can be applied to describe data and statistical results, one should be aware of reasonable methods with which to use SD and SEM. We aim to elucidate the distinctions between SD and SEM and to provide proper usage guidelines for both, which summarize data and describe statistical results. PMID:26045923

  13. Sample sizes needed for specified margins of relative error in the estimates of the repeatability and reproducibility standard deviations.

    PubMed

    McClure, Foster D; Lee, Jung K

    2005-01-01

    Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.

  14. Robust Confidence Interval for a Ratio of Standard Deviations

    ERIC Educational Resources Information Center

    Bonett, Douglas G.

    2006-01-01

    Comparing variability of test scores across alternate forms, test conditions, or subpopulations is a fundamental problem in psychometrics. A confidence interval for a ratio of standard deviations is proposed that performs as well as the classic method with normal distributions and performs dramatically better with nonnormal distributions. A simple…

  15. Refined multiscale fuzzy entropy based on standard deviation for biomedical signal analysis.

    PubMed

    Azami, Hamed; Fernández, Alberto; Escudero, Javier

    2017-11-01

    Multiscale entropy (MSE) has been a prevalent algorithm to quantify the complexity of biomedical time series. Recent developments in the field have tried to alleviate the problem of undefined MSE values for short signals. Moreover, there has been a recent interest in using other statistical moments than the mean, i.e., variance, in the coarse-graining step of the MSE. Building on these trends, here we introduce the so-called refined composite multiscale fuzzy entropy based on the standard deviation (RCMFE σ ) and mean (RCMFE μ ) to quantify the dynamical properties of spread and mean, respectively, over multiple time scales. We demonstrate the dependency of the RCMFE σ and RCMFE μ , in comparison with other multiscale approaches, on several straightforward signal processing concepts using a set of synthetic signals. The results evidenced that the RCMFE σ and RCMFE μ values are more stable and reliable than the classical multiscale entropy ones. We also inspect the ability of using the standard deviation as well as the mean in the coarse-graining process using magnetoencephalograms in Alzheimer's disease and publicly available electroencephalograms recorded from focal and non-focal areas in epilepsy. Our results indicated that when the RCMFE μ cannot distinguish different types of dynamics of a particular time series at some scale factors, the RCMFE σ may do so, and vice versa. The results showed that RCMFE σ -based features lead to higher classification accuracies in comparison with the RCMFE μ -based ones. We also made freely available all the Matlab codes used in this study at http://dx.doi.org/10.7488/ds/1477 .

  16. Role of a Standardized Prism Under Cover Test in the Assessment of Dissociated Vertical Deviation.

    PubMed

    Klaehn, Lindsay D; Hatt, Sarah R; Leske, David A; Holmes, Jonathan M

    2018-03-01

    Dissociated vertical deviation (DVD) is commonly measured using a prism and alternate cover test (PACT), but some providers use a prism under cover test (PUCT). The aim of this study was to compare a standardized PUCT measurement with a PACT measurement, for assessing the magnitude of DVD. Thirty-six patients with a clinical diagnosis of DVD underwent measurement of the angle of deviation with the PACT, fixing with the habitually fixing eye, and with PUCT, fixing both right and left eyes. The PUCT was standardized, using a 10-second cover for each prism magnitude, until the deviation was neutralized. The magnitude of hyperdeviation by PACT and PUCT was compared for the non-fixing eye, using paired non-parametric tests. The frequency of discrepancies more than 4 prism diopters (PD) between PACT and PUCT was calculated. The magnitude of hyperdeviation was greater when measured with PUCT (range 8PD hypodeviation to 20PD hyperdeviation) vs. PACT (18PD hypodeviation to 25PD hyperdeviation) with a median difference of 4.5PD (range -5PD to 21PD); P < 0.0001. Eighteen (50%) of 36 measurements elicited >4PD hyperdeviation (or >4PD less hypodeviation) by PUCT than by PACT. A standardized 10-second PUCT yields greater values than a prism and alternate cover test in the majority of patients with DVD, providing better quantification of the severity of DVD, which may be important for management decisions.

  17. ARFI cut-off values and significance of standard deviation for liver fibrosis staging in patients with chronic liver disease.

    PubMed

    Goertz, Ruediger S; Sturm, Joerg; Pfeifer, Lukas; Wildner, Dane; Wachter, David L; Neurath, Markus F; Strobel, Deike

    2013-01-01

    Acoustic radiation force impulse (ARFI) elastometry quantifies hepatic stiffness, and thus degree of fibrosis, non-invasively. Our aim was to analyse the diagnostic accuracy of ARFI cut-off values, and the significance of a defined limit of standard deviation (SD) as a potential quality parameter for liver fibrosis staging in patients with chronic liver diseases (CLD). 153 patients with CLD (various aetiologies) undergoing liver biopsy, and an additional 25 patients with known liver cirrhosis, were investigated. ARFI measurements were performed in the right hepatic lobe, and correlated with the histopathological Ludwig fibrosis score (inclusion criteria: at least 6 portal tracts). The diagnostic accuracy of cut-off values was analysed with respect to an SD limit of 30% of the mean ARFI value. The mean ARFI elastometry showed 1.95 ± 0.87 m/s (range 0.79-4.40) in 178 patients (80 female, 98 male, mean age: 52 years). The cut-offs were 1.25 m/s for F ≥ 2, 1.72 m/s for F ≥ 3 and 1.75 m/s for F = 4, and the corresponding AUROC 80.7%, 86.2% and 88.7%, respectively. Exclusion of 31 patients (17.4%) with an SD higher than 30% of the mean ARFI improved the diagnostic accuracy: The AUROC for F ≥ 2, F ≥ 3 and F = 4 were 86.1%, 91.2% and 91.5%, respectively. The diagnostic accuracy of ARFI can be improved by applying a maximum SD of 30% of the mean ARFI as a quality parameter--which however leads to an exclusion of a relevant number of patients. ARFI results with a high SD should be interpreted with caution.

  18. Variation in the standard deviation of the lure rating distribution: Implications for estimates of recollection probability.

    PubMed

    Dopkins, Stephen; Varner, Kaitlin; Hoyer, Darin

    2017-10-01

    In word recognition semantic priming of test words increased the false-alarm rate and the mean of confidence ratings to lures. Such priming also increased the standard deviation of confidence ratings to lures and the slope of the z-ROC function, suggesting that the priming increased the standard deviation of the lure evidence distribution. The Unequal Variance Signal Detection (UVSD) model interpreted the priming as increasing the standard deviation of the lure evidence distribution. Without additional parameters the Dual Process Signal Detection (DPSD) model could only accommodate the results by fitting the data for related and unrelated primes separately, interpreting the priming, implausibly, as decreasing the probability of target recollection (DPSD). With an additional parameter, for the probability of false (lure) recollection the model could fit the data for related and unrelated primes together, interpreting the priming as increasing the probability of false recollection. These results suggest that DPSD estimates of target recollection probability will decrease with increases in the lure confidence/evidence standard deviation unless a parameter is included for false recollection. Unfortunately the size of a given lure confidence/evidence standard deviation relative to other possible lure confidence/evidence standard deviations is often unspecified by context. Hence the model often has no way of estimating false recollection probability and thereby correcting its estimates of target recollection probability.

  19. Standard deviation of scatterometer measurements from space.

    NASA Technical Reports Server (NTRS)

    Fischer, R. E.

    1972-01-01

    The standard deviation of scatterometer measurements has been derived under assumptions applicable to spaceborne scatterometers. Numerical results are presented which show that, with sufficiently long integration times, input signal-to-noise ratios below unity do not cause excessive degradation of measurement accuracy. The effects on measurement accuracy due to varying integration times and changing the ratio of signal bandwidth to IF filter-noise bandwidth are also plotted. The results of the analysis may resolve a controversy by showing that in fact statistically useful scatterometer measurements can be made from space using a 20-W transmitter, such as will be used on the S-193 experiment for Skylab-A.

  20. Repeatable source, site, and path effects on the standard deviation for empirical ground-motion prediction models

    USGS Publications Warehouse

    Lin, P.-S.; Chiou, B.; Abrahamson, N.; Walling, M.; Lee, C.-T.; Cheng, C.-T.

    2011-01-01

    In this study, we quantify the reduction in the standard deviation for empirical ground-motion prediction models by removing ergodic assumption.We partition the modeling error (residual) into five components, three of which represent the repeatable source-location-specific, site-specific, and path-specific deviations from the population mean. A variance estimation procedure of these error components is developed for use with a set of recordings from earthquakes not heavily clustered in space.With most source locations and propagation paths sampled only once, we opt to exploit the spatial correlation of residuals to estimate the variances associated with the path-specific and the source-location-specific deviations. The estimation procedure is applied to ground-motion amplitudes from 64 shallow earthquakes in Taiwan recorded at 285 sites with at least 10 recordings per site. The estimated variance components are used to quantify the reduction in aleatory variability that can be used in hazard analysis for a single site and for a single path. For peak ground acceleration and spectral accelerations at periods of 0.1, 0.3, 0.5, 1.0, and 3.0 s, we find that the singlesite standard deviations are 9%-14% smaller than the total standard deviation, whereas the single-path standard deviations are 39%-47% smaller.

  1. Closed-form confidence intervals for functions of the normal mean and standard deviation.

    PubMed

    Donner, Allan; Zou, G Y

    2012-08-01

    Confidence interval methods for a normal mean and standard deviation are well known and simple to apply. However, the same cannot be said for important functions of these parameters. These functions include the normal distribution percentiles, the Bland-Altman limits of agreement, the coefficient of variation and Cohen's effect size. We present a simple approach to this problem by using variance estimates recovered from confidence limits computed for the mean and standard deviation separately. All resulting confidence intervals have closed forms. Simulation results demonstrate that this approach performs very well for limits of agreement, coefficients of variation and their differences.

  2. Poorer right ventricular systolic function and exercise capacity in women after repair of tetralogy of fallot: a sex comparison of standard deviation scores based on sex-specific reference values in healthy control subjects.

    PubMed

    Sarikouch, Samir; Boethig, Dietmar; Peters, Brigitte; Kropf, Siegfried; Dubowy, Karl-Otto; Lange, Peter; Kuehne, Titus; Haverich, Axel; Beerbaum, Philipp

    2013-11-01

    In repaired congenital heart disease, there is increasing evidence of sex differences in cardiac remodeling, but there is a lack of comparable data for specific congenital heart defects such as in repaired tetralogy of Fallot. In a prospective multicenter study, a cohort of 272 contemporary patients (158 men; mean age, 14.3±3.3 years [range, 8-20 years]) with repaired tetralogy of Fallot underwent cardiac magnetic resonance for ventricular function and metabolic exercise testing. All data were transformed to standard deviation scores according to the Lambda-Mu-Sigma method by relating individual values to their respective 50th percentile (standard deviation score, 0) in sex-specific healthy control subjects. No sex differences were observed in age at repair, type of repair conducted, or overall hemodynamic results. Relative to sex-specific controls, repaired tetralogy of Fallot in women had larger right ventricular end-systolic volumes (standard deviation scores: women, 4.35; men, 3.25; P=0.001), lower right ventricular ejection fraction (women, -2.83; men, -2.12; P=0.011), lower right ventricular muscle mass (women, 1.58; men 2.45; P=0.001), poorer peak oxygen uptake (women, -1.65; men, -1.14; P<0.001), higher VE/VCO2 (ventilation per unit of carbon dioxide production) slopes (women, 0.88; men 0.58; P=0.012), and reduced peak heart rate (women, -2.16; men -1.74; P=0.017). Left ventricular parameters did not differ between sexes. Relative to their respective sex-specific healthy control subjects, derived standard deviation scores in repaired tetralogy of Fallot suggest that women perform poorer than men in terms of right ventricular systolic function as tested by cardiac magnetic resonance and exercise capacity. This effect cannot be explained by selection bias. Further outcome data are required from longitudinal cohort studies.

  3. Spectral relative standard deviation: a practical benchmark in metabolomics.

    PubMed

    Parsons, Helen M; Ekman, Drew R; Collette, Timothy W; Viant, Mark R

    2009-03-01

    Metabolomics datasets, by definition, comprise of measurements of large numbers of metabolites. Both technical (analytical) and biological factors will induce variation within these measurements that is not consistent across all metabolites. Consequently, criteria are required to assess the reproducibility of metabolomics datasets that are derived from all the detected metabolites. Here we calculate spectrum-wide relative standard deviations (RSDs; also termed coefficient of variation, CV) for ten metabolomics datasets, spanning a variety of sample types from mammals, fish, invertebrates and a cell line, and display them succinctly as boxplots. We demonstrate multiple applications of spectral RSDs for characterising technical as well as inter-individual biological variation: for optimising metabolite extractions, comparing analytical techniques, investigating matrix effects, and comparing biofluids and tissue extracts from single and multiple species for optimising experimental design. Technical variation within metabolomics datasets, recorded using one- and two-dimensional NMR and mass spectrometry, ranges from 1.6 to 20.6% (reported as the median spectral RSD). Inter-individual biological variation is typically larger, ranging from as low as 7.2% for tissue extracts from laboratory-housed rats to 58.4% for fish plasma. In addition, for some of the datasets we confirm that the spectral RSD values are largely invariant across different spectral processing methods, such as baseline correction, normalisation and binning resolution. In conclusion, we propose spectral RSDs and their median values contained herein as practical benchmarks for metabolomics studies.

  4. Reduction in mean deviation values in automated perimetry in eyes with multifocal compared to monofocal intraocular lens implants.

    PubMed

    Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F

    2014-08-01

    To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Dealing with missing standard deviation and mean values in meta-analysis of continuous outcomes: a systematic review.

    PubMed

    Weir, Christopher J; Butcher, Isabella; Assi, Valentina; Lewis, Stephanie C; Murray, Gordon D; Langhorne, Peter; Brady, Marian C

    2018-03-07

    Rigorous, informative meta-analyses rely on availability of appropriate summary statistics or individual participant data. For continuous outcomes, especially those with naturally skewed distributions, summary information on the mean or variability often goes unreported. While full reporting of original trial data is the ideal, we sought to identify methods for handling unreported mean or variability summary statistics in meta-analysis. We undertook two systematic literature reviews to identify methodological approaches used to deal with missing mean or variability summary statistics. Five electronic databases were searched, in addition to the Cochrane Colloquium abstract books and the Cochrane Statistics Methods Group mailing list archive. We also conducted cited reference searching and emailed topic experts to identify recent methodological developments. Details recorded included the description of the method, the information required to implement the method, any underlying assumptions and whether the method could be readily applied in standard statistical software. We provided a summary description of the methods identified, illustrating selected methods in example meta-analysis scenarios. For missing standard deviations (SDs), following screening of 503 articles, fifteen methods were identified in addition to those reported in a previous review. These included Bayesian hierarchical modelling at the meta-analysis level; summary statistic level imputation based on observed SD values from other trials in the meta-analysis; a practical approximation based on the range; and algebraic estimation of the SD based on other summary statistics. Following screening of 1124 articles for methods estimating the mean, one approximate Bayesian computation approach and three papers based on alternative summary statistics were identified. Illustrative meta-analyses showed that when replacing a missing SD the approximation using the range minimised loss of precision and generally

  6. Phase-I monitoring of standard deviations in multistage linear profiles

    NASA Astrophysics Data System (ADS)

    Kalaei, Mahdiyeh; Soleimani, Paria; Niaki, Seyed Taghi Akhavan; Atashgar, Karim

    2018-03-01

    In most modern manufacturing systems, products are often the output of some multistage processes. In these processes, the stages are dependent on each other, where the output quality of each stage depends also on the output quality of the previous stages. This property is called the cascade property. Although there are many studies in multistage process monitoring, there are fewer works on profile monitoring in multistage processes, especially on the variability monitoring of a multistage profile in Phase-I for which no research is found in the literature. In this paper, a new methodology is proposed to monitor the standard deviation involved in a simple linear profile designed in Phase I to monitor multistage processes with the cascade property. To this aim, an autoregressive correlation model between the stages is considered first. Then, the effect of the cascade property on the performances of three types of T 2 control charts in Phase I with shifts in standard deviation is investigated. As we show that this effect is significant, a U statistic is next used to remove the cascade effect, based on which the investigated control charts are modified. Simulation studies reveal good performances of the modified control charts.

  7. Is standard deviation of daily PM2.5 concentration associated with respiratory mortality?

    PubMed

    Lin, Hualiang; Ma, Wenjun; Qiu, Hong; Vaughn, Michael G; Nelson, Erik J; Qian, Zhengmin; Tian, Linwei

    2016-09-01

    Studies on health effects of air pollution often use daily mean concentration to estimate exposure while ignoring daily variations. This study examined the health effects of daily variation of PM2.5. We calculated daily mean and standard deviations of PM2.5 in Hong Kong between 1998 and 2011. We used a generalized additive model to estimate the association between respiratory mortality and daily mean and variation of PM2.5, as well as their interaction. We controlled for potential confounders, including temporal trends, day of the week, meteorological factors, and gaseous air pollutants. Both daily mean and standard deviation of PM2.5 were significantly associated with mortalities from overall respiratory diseases and pneumonia. Each 10 μg/m(3) increment in daily mean concentration at lag 2 day was associated with a 0.61% (95% CI: 0.19%, 1.03%) increase in overall respiratory mortality and a 0.67% (95% CI: 0.14%, 1.21%) increase in pneumonia mortality. And a 10 μg/m(3) increase in standard deviation at lag 1 day corresponded to a 1.40% (95% CI: 0.35%, 2.46%) increase in overall respiratory mortality, and a 1.80% (95% CI: 0.46%, 3.16%) increase in pneumonia mortality. We also observed a positive but non-significant synergistic interaction between daily mean and variation on respiratory mortality and pneumonia mortality. However, we did not find any significant association with mortality from chronic obstructive pulmonary diseases. Our study suggests that, besides mean concentration, the standard deviation of PM2.5 might be one potential predictor of respiratory mortality in Hong Kong, and should be considered when assessing the respiratory effects of PM2.5. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Do pattern deviation values accurately estimate glaucomatous visual field damage in eyes with glaucoma and cataract?

    PubMed

    Matsuda, Aya; Hara, Takeshi; Miyata, Kazunori; Matsuo, Hiroshi; Murata, Hiroshi; Mayama, Chihiro; Asaoka, Ryo

    2015-09-01

    To study the efficacy of pattern deviation (PD) values in the estimation of visual field compensating the influence of cataract in eyes with glaucoma. The study subjects comprised of 48 eyes of 37 glaucoma patients. Mean total deviation value (mTDs) on Humphrey Field Analyzer after cataract surgery was compared with mean PD (mPD) before the surgery. Visual field measurements were carried out ≤6 months before (VF(pre)) and following (VF(post)) successful cataract surgery. The difference between the mPD or mTD values in the VF(pre) and mTD values in the VF(post) (denoted as εmPD/ΔmTD) was calculated, and the influence of the extent of 'true' glaucomatous visual field damage or cataract (as represented by εmPD and ΔmTD, respectively) on this difference was also investigated. There was a significant difference between mTD in the VF(pre) and mTD in the VF(post) (p<0.001, repeated measures analysis of variance). There was not a significant difference between mPD in the VF(pre) and mTD in the VF(post) (p=0.06); however, εmPD was significantly correlated with the mTD in VF(post) and also ΔmTD (R(2)=0.56 and 0.27, p<0.001, Pearson's correlation). The accurate prediction of the mTD in the VF(post) can be achieved using the pattern standard deviation (PSD), mTD and also visual acuity before surgery. Clinicians should be very careful when reviewing the VF of a patient with glaucoma and cataract since PD values may underestimate glaucomatous VF damage in patients with advanced disease and also overestimate glaucomatous VF damage in patients with early to moderate cataract. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data

    NASA Astrophysics Data System (ADS)

    Shulenin, V. P.

    2016-10-01

    Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.

  10. Simulation-based estimation of mean and standard deviation for meta-analysis via Approximate Bayesian Computation (ABC).

    PubMed

    Kwon, Deukwoo; Reis, Isildinha M

    2015-08-12

    When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.

  11. Comparison of estimators of standard deviation for hydrologic time series

    USGS Publications Warehouse

    Tasker, Gary D.; Gilroy, Edward J.

    1982-01-01

    Unbiasing factors as a function of serial correlation, ρ, and sample size, n for the sample standard deviation of a lag one autoregressive model were generated by random number simulation. Monte Carlo experiments were used to compare the performance of several alternative methods for estimating the standard deviation σ of a lag one autoregressive model in terms of bias, root mean square error, probability of underestimation, and expected opportunity design loss. Three methods provided estimates of σ which were much less biased but had greater mean square errors than the usual estimate of σ: s = (1/(n - 1) ∑ (xi −x¯)2)½. The three methods may be briefly characterized as (1) a method using a maximum likelihood estimate of the unbiasing factor, (2) a method using an empirical Bayes estimate of the unbiasing factor, and (3) a robust nonparametric estimate of σ suggested by Quenouille. Because s tends to underestimate σ, its use as an estimate of a model parameter results in a tendency to underdesign. If underdesign losses are considered more serious than overdesign losses, then the choice of one of the less biased methods may be wise.

  12. An adaptive beamforming method for ultrasound imaging based on the mean-to-standard-deviation factor.

    PubMed

    Wang, Yuanguo; Zheng, Chichao; Peng, Hu; Chen, Qiang

    2018-06-12

    The beamforming performance has a large impact on image quality in ultrasound imaging. Previously, several adaptive weighting factors including coherence factor (CF) and generalized coherence factor (GCF) have been proposed to improved image resolution and contrast. In this paper, we propose a new adaptive weighting factor for ultrasound imaging, which is called signal mean-to-standard-deviation factor (SMSF). SMSF is defined as the mean-to-standard-deviation of the aperture data and is used to weight the output of delay-and-sum (DAS) beamformer before image formation. Moreover, we develop a robust SMSF (RSMSF) by extending the SMSF to the spatial frequency domain using an altered spectrum of the aperture data. In addition, a square neighborhood average is applied on the RSMSF to offer a more smoothed square neighborhood RSMSF (SN-RSMSF) value. We compared our methods with DAS, CF, and GCF using simulated and experimental synthetic aperture data sets. The quantitative results show that SMSF results in an 82% lower full width at half-maximum (FWHM) but a 12% lower contrast ratio (CR) compared with CF. Moreover, the SN-RSMSF leads to 15% and 10% improvement, on average, in FWHM and CR compared with GCF while maintaining the speckle quality. This demonstrates that the proposed methods can effectively improve the image resolution and contrast. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Scatter-Reducing Sounding Filtration Using a Genetic Algorithm and Mean Monthly Standard Deviation

    NASA Technical Reports Server (NTRS)

    Mandrake, Lukas

    2013-01-01

    Retrieval algorithms like that used by the Orbiting Carbon Observatory (OCO)-2 mission generate massive quantities of data of varying quality and reliability. A computationally efficient, simple method of labeling problematic datapoints or predicting soundings that will fail is required for basic operation, given that only 6% of the retrieved data may be operationally processed. This method automatically obtains a filter designed to reduce scatter based on a small number of input features. Most machine-learning filter construction algorithms attempt to predict error in the CO2 value. By using a surrogate goal of Mean Monthly STDEV, the goal is to reduce the retrieved CO2 scatter rather than solving the harder problem of reducing CO2 error. This lends itself to improved interpretability and performance. This software reduces the scatter of retrieved CO2 values globally based on a minimum number of input features. It can be used as a prefilter to reduce the number of soundings requested, or as a post-filter to label data quality. The use of the MMS (Mean Monthly Standard deviation) provides a much cleaner, clearer filter than the standard ABS(CO2-truth) metrics previously employed by competitor methods. The software's main strength lies in a clearer (i.e., fewer features required) filter that more efficiently reduces scatter in retrieved CO2 rather than focusing on the more complex (and easily removed) bias issues.

  14. 78 FR 2273 - Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-P-1189] Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... interstate shipment of experimental packs of food varying from the requirements of standards of identity...

  15. 75 FR 67093 - Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0517] Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... from the requirements of the standards of identity issued under section 401 of the Federal Food, Drug...

  16. Fidelity deviation in quantum teleportation

    NASA Astrophysics Data System (ADS)

    Bang, Jeongho; Ryu, Junghee; Kaszlikowski, Dagomir

    2018-04-01

    We analyze the performance of quantum teleportation in terms of average fidelity and fidelity deviation. The average fidelity is defined as the average value of the fidelities over all possible input states and the fidelity deviation is their standard deviation, which is referred to as a concept of fluctuation or universality. In the analysis, we find the condition to optimize both measures under a noisy quantum channel—we here consider the so-called Werner channel. To characterize our results, we introduce a 2D space defined by the aforementioned measures, in which the performance of the teleportation is represented as a point with the channel noise parameter. Through further analysis, we specify some regions drawn for different channel conditions, establishing the connection to the dissimilar contributions of the entanglement to the teleportation and the Bell inequality violation.

  17. Estimating maize water stress by standard deviation of canopy temperature in thermal imagery

    USDA-ARS?s Scientific Manuscript database

    A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...

  18. WASP (Write a Scientific Paper) using Excel -5: Quartiles and standard deviation.

    PubMed

    Grech, Victor

    2018-03-01

    The almost inevitable descriptive statistics exercise that is undergone once data collection is complete, prior to inferential statistics, requires the acquisition of basic descriptors which may include standard deviation and quartiles. This paper provides pointers as to how to do this in Microsoft Excel™ and explains the relationship between the two. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. An estimator for the standard deviation of a natural frequency. I.

    NASA Technical Reports Server (NTRS)

    Schiff, A. J.; Bogdanoff, J. L.

    1971-01-01

    A brief review of mean-square approximate systems is given. The case in which the masses are deterministic is considered first in the derivation of an estimator for the upper bound of the standard deviation of a natural frequency. Two examples presented include a two-degree-of-freedom system and a case in which the disorder in the springs is perfectly correlated. For purposes of comparison, a Monte Carlo simulation was done on a digital computer.

  20. The gait standard deviation, a single measure of kinematic variability.

    PubMed

    Sangeux, Morgan; Passmore, Elyse; Graham, H Kerr; Tirosh, Oren

    2016-05-01

    Measurement of gait kinematic variability provides relevant clinical information in certain conditions affecting the neuromotor control of movement. In this article, we present a measure of overall gait kinematic variability, GaitSD, based on combination of waveforms' standard deviation. The waveform standard deviation is the common numerator in established indices of variability such as Kadaba's coefficient of multiple correlation or Winter's waveform coefficient of variation. Gait data were collected on typically developing children aged 6-17 years. Large number of strides was captured for each child, average 45 (SD: 11) for kinematics and 19 (SD: 5) for kinetics. We used a bootstrap procedure to determine the precision of GaitSD as a function of the number of strides processed. We compared the within-subject, stride-to-stride, variability with the, between-subject, variability of the normative pattern. Finally, we investigated the correlation between age and gait kinematic, kinetic and spatio-temporal variability. In typically developing children, the relative precision of GaitSD was 10% as soon as 6 strides were captured. As a comparison, spatio-temporal parameters required 30 strides to reach the same relative precision. The ratio stride-to-stride divided by normative pattern variability was smaller in kinematic variables (the smallest for pelvic tilt, 28%) than in kinetic and spatio-temporal variables (the largest for normalised stride length, 95%). GaitSD had a strong, negative correlation with age. We show that gait consistency may stabilise only at, or after, skeletal maturity. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. A standard deviation selection in evolutionary algorithm for grouper fish feed formulation

    NASA Astrophysics Data System (ADS)

    Cai-Juan, Soong; Ramli, Razamin; Rahman, Rosshairy Abdul

    2016-10-01

    Malaysia is one of the major producer countries for fishery production due to its location in the equatorial environment. Grouper fish is one of the potential markets in contributing to the income of the country due to its desirable taste, high demand and high price. However, the demand of grouper fish is still insufficient from the wild catch. Therefore, there is a need to farm grouper fish to cater to the market demand. In order to farm grouper fish, there is a need to have prior knowledge of the proper nutrients needed because there is no exact data available. Therefore, in this study, primary data and secondary data are collected even though there is a limitation of related papers and 30 samples are investigated by using standard deviation selection in Evolutionary algorithm. Thus, this study would unlock frontiers for an extensive research in respect of grouper fish feed formulation. Results shown that the fitness of standard deviation selection in evolutionary algorithm is applicable. The feasible and low fitness, quick solution can be obtained. These fitness can be further predicted to minimize cost in farming grouper fish.

  2. What to use to express the variability of data: Standard deviation or standard error of mean?

    PubMed

    Barde, Mohini P; Barde, Prajakt J

    2012-07-01

    Statistics plays a vital role in biomedical research. It helps present data precisely and draws the meaningful conclusions. While presenting data, one should be aware of using adequate statistical measures. In biomedical journals, Standard Error of Mean (SEM) and Standard Deviation (SD) are used interchangeably to express the variability; though they measure different parameters. SEM quantifies uncertainty in estimate of the mean whereas SD indicates dispersion of the data from mean. As readers are generally interested in knowing the variability within sample, descriptive data should be precisely summarized with SD. Use of SEM should be limited to compute CI which measures the precision of population estimate. Journals can avoid such errors by requiring authors to adhere to their guidelines.

  3. Analytical quality goals derived from the total deviation from patients' homeostatic set points, with a margin for analytical errors.

    PubMed

    Bolann, B J; Asberg, A

    2004-01-01

    The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.

  4. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    PubMed

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Use of Standard Deviations as Predictors in Models Using Large-Scale International Data Sets

    ERIC Educational Resources Information Center

    Austin, Bruce; French, Brian; Adesope, Olusola; Gotch, Chad

    2017-01-01

    Measures of variability are successfully used in predictive modeling in research areas outside of education. This study examined how standard deviations can be used to address research questions not easily addressed using traditional measures such as group means based on index variables. Student survey data were obtained from the Organisation for…

  6. The two errors of using the within-subject standard deviation (WSD) as the standard error of a reliable change index.

    PubMed

    Maassen, Gerard H

    2010-08-01

    In this Journal, Lewis and colleagues introduced a new Reliable Change Index (RCI(WSD)), which incorporated the within-subject standard deviation (WSD) of a repeated measurement design as the standard error. In this note, two opposite errors in using WSD this way are demonstrated. First, being the standard error of measurement of only a single assessment makes WSD too small when practice effects are absent. Then, too many individuals will be designated reliably changed. Second, WSD can grow unlimitedly to the extent that differential practice effects occur. This can even make RCI(WSD) unable to detect any reliable change.

  7. Differential standard deviation of log-scale intensity based optical coherence tomography angiography.

    PubMed

    Shi, Weisong; Gao, Wanrong; Chen, Chaoliang; Yang, Victor X D

    2017-12-01

    In this paper, a differential standard deviation of log-scale intensity (DSDLI) based optical coherence tomography angiography (OCTA) is presented for calculating microvascular images of human skin. The DSDLI algorithm calculates the variance in difference images of two consecutive log-scale intensity based structural images from the same position along depth direction to contrast blood flow. The en face microvascular images were then generated by calculating the standard deviation of the differential log-scale intensities within the specific depth range, resulting in an improvement in spatial resolution and SNR in microvascular images compared to speckle variance OCT and power intensity differential method. The performance of DSDLI was testified by both phantom and in vivo experiments. In in vivo experiments, a self-adaptive sub-pixel image registration algorithm was performed to remove the bulk motion noise, where 2D Fourier transform was utilized to generate new images with spatial interval equal to half of the distance between two pixels in both fast-scanning and depth directions. The SNRs of signals of flowing particles are improved by 7.3 dB and 6.8 dB on average in phantom and in vivo experiments, respectively, while the average spatial resolution of images of in vivo blood vessels is increased by 21%. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    PubMed Central

    Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie

    2008-01-01

    This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396

  9. Assessing the stock market volatility for different sectors in Malaysia by using standard deviation and EWMA methods

    NASA Astrophysics Data System (ADS)

    Saad, Shakila; Ahmad, Noryati; Jaffar, Maheran Mohd

    2017-11-01

    Nowadays, the study on volatility concept especially in stock market has gained so much attention from a group of people engaged in financial and economic sectors. The applications of volatility concept in financial economics can be seen in valuation of option pricing, estimation of financial derivatives, hedging the investment risk and etc. There are various ways to measure the volatility value. However for this study, two methods are used; the simple standard deviation and Exponentially Weighted Moving Average (EWMA). The focus of this study is to measure the volatility on three different sectors of business in Malaysia, called primary, secondary and tertiary by using both methods. The daily and annual volatilities of different business sector based on stock prices for the period of 1 January 2014 to December 2014 have been calculated in this study. Result shows that different patterns of the closing stock prices and return give different volatility values when calculating using simple method and EWMA method.

  10. Statistical analysis of solid waste composition data: Arithmetic mean, standard deviation and correlation coefficients.

    PubMed

    Edjabou, Maklawe Essonanawe; Martín-Fernández, Josep Antoni; Scheutz, Charlotte; Astrup, Thomas Fruergaard

    2017-11-01

    Data for fractional solid waste composition provide relative magnitudes of individual waste fractions, the percentages of which always sum to 100, thereby connecting them intrinsically. Due to this sum constraint, waste composition data represent closed data, and their interpretation and analysis require statistical methods, other than classical statistics that are suitable only for non-constrained data such as absolute values. However, the closed characteristics of waste composition data are often ignored when analysed. The results of this study showed, for example, that unavoidable animal-derived food waste amounted to 2.21±3.12% with a confidence interval of (-4.03; 8.45), which highlights the problem of the biased negative proportions. A Pearson's correlation test, applied to waste fraction generation (kg mass), indicated a positive correlation between avoidable vegetable food waste and plastic packaging. However, correlation tests applied to waste fraction compositions (percentage values) showed a negative association in this regard, thus demonstrating that statistical analyses applied to compositional waste fraction data, without addressing the closed characteristics of these data, have the potential to generate spurious or misleading results. Therefore, ¨compositional data should be transformed adequately prior to any statistical analysis, such as computing mean, standard deviation and correlation coefficients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Multiplicative surrogate standard deviation: a group metric for the glycemic variability of individual hospitalized patients.

    PubMed

    Braithwaite, Susan S; Umpierrez, Guillermo E; Chase, J Geoffrey

    2013-09-01

    Group metrics are described to quantify blood glucose (BG) variability of hospitalized patients. The "multiplicative surrogate standard deviation" (MSSD) is the reverse-transformed group mean of the standard deviations (SDs) of the logarithmically transformed BG data set of each patient. The "geometric group mean" (GGM) is the reverse-transformed group mean of the means of the logarithmically transformed BG data set of each patient. Before reverse transformation is performed, the mean of means and mean of SDs each has its own SD, which becomes a multiplicative standard deviation (MSD) after reverse transformation. Statistical predictions and comparisons of parametric or nonparametric tests remain valid after reverse transformation. A subset of a previously published BG data set of 20 critically ill patients from the first 72 h of treatment under the SPRINT protocol was transformed logarithmically. After rank ordering according to the SD of the logarithmically transformed BG data of each patient, the cohort was divided into two equal groups, those having lower or higher variability. For the entire cohort, the GGM was 106 (÷/× 1.07) mg/dl, and MSSD was 1.24 (÷/× 1.07). For the subgroups having lower and higher variability, respectively, the GGM did not differ, 104 (÷/× 1.07) versus 109 (÷/× 1.07) mg/dl, but the MSSD differed, 1.17 (÷/× 1.03) versus 1.31 (÷/× 1.05), p = .00004. By using the MSSD with its MSD, groups can be characterized and compared according to glycemic variability of individual patient members. © 2013 Diabetes Technology Society.

  12. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  13. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  14. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  15. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  16. 10 CFR 961.4 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...

  17. MUSiC - Model-independent search for deviations from Standard Model predictions in CMS

    NASA Astrophysics Data System (ADS)

    Pieta, Holger

    2010-02-01

    We present an approach for a model independent search in CMS. Systematically scanning the data for deviations from the standard model Monte Carlo expectations, such an analysis can help to understand the detector and tune event generators. By minimizing the theoretical bias the analysis is furthermore sensitive to a wide range of models for new physics, including the uncounted number of models not-yet-thought-of. After sorting the events into classes defined by their particle content (leptons, photons, jets and missing transverse energy), a minimally prejudiced scan is performed on a number of distributions. Advanced statistical methods are used to determine the significance of the deviating regions, rigorously taking systematic uncertainties into account. A number of benchmark scenarios, including common models of new physics and possible detector effects, have been used to gauge the power of such a method. )

  18. Comparing biomarker measurements to a normal range: when to use standard error of the mean (SEM) or standard deviation (SD) confidence intervals tests.

    PubMed

    Pleil, Joachim D

    2016-01-01

    This commentary is the second of a series outlining one specific concept in interpreting biomarkers data. In the first, an observational method was presented for assessing the distribution of measurements before making parametric calculations. Here, the discussion revolves around the next step, the choice of using standard error of the mean or the calculated standard deviation to compare or predict measurement results.

  19. Degrees of Freedom for Allan Deviation Estimates of Multiple Clocks

    DTIC Science & Technology

    2016-04-01

    Allan deviation . Allan deviation will be represented by σ and standard deviation will be represented by δ. In practice, when the Allan deviation of a...the Allan deviation of standard noise types. Once the number of degrees of freedom is known, an approximate confidence interval can be assigned by...measurement errors from paired difference data. We extend this approach by using the Allan deviation to estimate the error in a frequency standard

  20. Standard deviation analysis of the mastoid fossa temperature differential reading: a potential model for objective chiropractic assessment.

    PubMed

    Hart, John

    2011-03-01

    This study describes a model for statistically analyzing follow-up numeric-based chiropractic spinal assessments for an individual patient based on his or her own baseline. Ten mastoid fossa temperature differential readings (MFTD) obtained from a chiropractic patient were used in the study. The first eight readings served as baseline and were compared to post-adjustment readings. One of the two post-adjustment MFTD readings fell outside two standard deviations of the baseline mean and therefore theoretically represents improvement according to pattern analysis theory. This study showed how standard deviation analysis may be used to identify future outliers for an individual patient based on his or her own baseline data. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  1. Image contrast enhancement based on a local standard deviation model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Dah-Chung; Wu, Wen-Rong

    1996-12-31

    The adaptive contrast enhancement (ACE) algorithm is a widely used image enhancement method, which needs a contrast gain to adjust high frequency components of an image. In the literature, the gain is usually inversely proportional to the local standard deviation (LSD) or is a constant. But these cause two problems in practical applications, i.e., noise overenhancement and ringing artifact. In this paper a new gain is developed based on Hunt`s Gaussian image model to prevent the two defects. The new gain is a nonlinear function of LSD and has the desired characteristic emphasizing the LSD regions in which details aremore » concentrated. We have applied the new ACE algorithm to chest x-ray images and the simulations show the effectiveness of the proposed algorithm.« less

  2. On the linear relation between the mean and the standard deviation of a response time distribution.

    PubMed

    Wagenmakers, Eric-Jan; Brown, Scott

    2007-07-01

    Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different experimental paradigms support a linear relation between RT mean and RT standard deviation. Both R. Ratcliff's (1978) diffusion model and G. D. Logan's (1988) instance theory of automatization provide explanations for this linear relation. The authors identify and discuss 3 specific boundary conditions for the linear law to hold. The law constrains RT models and supports the use of the coefficient of variation to (a) compare variability while controlling for differences in baseline speed of processing and (b) assess whether changes in performance with practice are due to quantitative speedup or qualitative reorganization. Copyright 2007 APA.

  3. Standard deviation of luminance distribution affects lightness and pupillary response.

    PubMed

    Kanari, Kei; Kaneko, Hirohiko

    2014-12-01

    We examined whether the standard deviation (SD) of luminance distribution serves as information of illumination. We measured the lightness of a patch presented in the center of a scrambled-dot pattern while manipulating the SD of the luminance distribution. Results showed that lightness decreased as the SD of the surround stimulus increased. We also measured pupil diameter while viewing a similar stimulus. The pupil diameter decreased as the SD of luminance distribution of the stimuli increased. We confirmed that these results were not obtained because of the increase of the highest luminance in the stimulus. Furthermore, results of field measurements revealed a correlation between the SD of luminance distribution and illuminance in natural scenes. These results indicated that the visual system refers to the SD of the luminance distribution in the visual stimulus to estimate the scene illumination.

  4. Formulae Based on Biomathematics to Estimate the Standard Value of Fetal Growth of Japanese.

    PubMed

    Miyagi, Yasunari; Tada, Katsuhiko; Takayoshi, Riko; Oguni, Nobutsugu; Sato, Yasushi; Shibata, Maki; Kiyokawa, Machiko; Hashimoto, Tadashi; Takada, Tomoyoshi; Oda, Takashi; Miyake, Takahito

    2018-04-01

    We devised biomathematics-based formulae to estimate the standard values of fetal growth of Japanese after 22 weeks' gestation. The growth rates of bi-parietal diameter (BPD), abdominal circumference (AC), femur length (FL), and estimated fetal body weight (EFBW) at the time of gestation were assumed to be proportional to the product of the value at the time and the rest value of an unknown maximum value, respectively. The EFBW was also assumed to follow a multiple logistic function of BPD, AC and FL to fit the standard values of Japanese fetuses published by the Japan Society of Ultrasonics in Medicine. The Mann-Whitney test was used for statistical analysis. The values as a function of gestational day, t, were as follows: BPD(t)=99.6/(1+exp (2.725-0.01837*t)) (mm); AC(t)=39.7/(1+exp (2.454-0.01379*t)) (cm); FL(t)=79.6/(1+exp (2.851-0.01710*t)) (mm); EFBW(t)=8045.1/(1+exp (6.028-0.06582*BPD(t)-0.1469*AC(t)+ 0.07377*FL(t))) (g). EFBW as a function of BPD, AC and FL was as follows: EFBW=8045.1/(1+exp (4.747+ 0.02584*BPD+0.1010*AC-0.1416*FL)) (g). When the BPD, AC and FL were at -2 standard deviation (SD), -1SD, mean and + 2SD, the EFBW values calculated by the formula were statistically closer to the standard values than conventional formulas with p-values of 4.871×10-7, 4.228×10-7, 9.777×10-7 and 0.028, respectively. The formulae based on biomathematics might be useful to estimate the fetal growth standard values.

  5. Odds per Adjusted Standard Deviation: Comparing Strengths of Associations for Risk Factors Measured on Different Scales and Across Diseases and Populations

    PubMed Central

    Hopper, John L.

    2015-01-01

    How can the “strengths” of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors—and that is how risk gradients are interpreted—so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RRs. This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. PMID:26520360

  6. Diurnal Dynamics of Standard Deviations of Three Wind Velocity Components in the Atmospheric Boundary Layer

    NASA Astrophysics Data System (ADS)

    Shamanaeva, L. G.; Krasnenko, N. P.; Kapegesheva, O. F.

    2018-04-01

    Diurnal dynamics of the standard deviation (SD) of three wind velocity components measured with a minisodar in the atmospheric boundary layer is analyzed. Statistical analysis of measurement data demonstrates that the SDs for x- and y-components σx and σy lie in the range from 0.2 to 4 m/s, and σz = 0.1-1.2 m/s. The increase of σx and σy with the altitude is described sufficiently well by a power law with exponent changing from 0.22 to 1.3 depending on time of day, and σz increases by a linear law. Approximation constants are determined and errors of their application are estimated. It is found that the maximal diurnal spread of SD values is 56% for σx and σy and 94% for σz. The established physical laws and the obtained approximation constants allow the diurnal dynamics of the SDs for three wind velocity components in the atmospheric boundary layer to be determined and can be recommended for application in models of the atmospheric boundary layer.

  7. Deviation Value for Conventional X-ray in Hospitals in South Sulawesi Province from 2014 to 2016

    NASA Astrophysics Data System (ADS)

    Bachtiar, Ilham; Abdullah, Bualkar; Tahir, Dahlan

    2018-03-01

    This paper describes the conventional X-ray machine parameters tested in the region of South Sulawesi from 2014 to 2016. The objective of this research is to know deviation of every parameter of conventional X-ray machine. The testing parameters were analyzed by using quantitative methods with participatory observational approach. Data collection was performed by testing the output of conventional X-ray plane using non-invasive x-ray multimeter. The test parameters include tube voltage (kV) accuracy, radiation output linearity, reproducibility and radiation beam value (HVL) quality. The results of the analysis show four conventional X-ray test parameters have varying deviation spans, where the tube voltage (kV) accuracy has an average value of 4.12%, the average radiation output linearity is 4.47% of the average reproducibility of 0.62% and the averaged of the radiation beam (HVL) is 3.00 mm.

  8. On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution

    ERIC Educational Resources Information Center

    Wagenmakers, Eric-Jan; Brown, Scott

    2007-01-01

    Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…

  9. allantools: Allan deviation calculation

    NASA Astrophysics Data System (ADS)

    Wallin, Anders E. E.; Price, Danny C.; Carson, Cantwell G.; Meynadier, Frédéric

    2018-04-01

    allantools calculates Allan deviation and related time & frequency statistics. The library is written in Python and has a GPL v3+ license. It takes input data that is either evenly spaced observations of either fractional frequency, or phase in seconds. Deviations are calculated for given tau values in seconds. Several noise generators for creating synthetic datasets are also included.

  10. Multi-focus image fusion based on area-based standard deviation in dual tree contourlet transform domain

    NASA Astrophysics Data System (ADS)

    Dong, Min; Dong, Chenghui; Guo, Miao; Wang, Zhe; Mu, Xiaomin

    2018-04-01

    Multiresolution-based methods, such as wavelet and Contourlet are usually used to image fusion. This work presents a new image fusion frame-work by utilizing area-based standard deviation in dual tree Contourlet trans-form domain. Firstly, the pre-registered source images are decomposed with dual tree Contourlet transform; low-pass and high-pass coefficients are obtained. Then, the low-pass bands are fused with weighted average based on area standard deviation rather than the simple "averaging" rule. While the high-pass bands are merged with the "max-absolute' fusion rule. Finally, the modified low-pass and high-pass coefficients are used to reconstruct the final fused image. The major advantage of the proposed fusion method over conventional fusion is the approximately shift invariance and multidirectional selectivity of dual tree Contourlet transform. The proposed method is compared with wavelet- , Contourletbased methods and other the state-of-the art methods on common used multi focus images. Experiments demonstrate that the proposed fusion framework is feasible and effective, and it performs better in both subjective and objective evaluation.

  11. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP).

    PubMed

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.

  12. Odds per adjusted standard deviation: comparing strengths of associations for risk factors measured on different scales and across diseases and populations.

    PubMed

    Hopper, John L

    2015-11-15

    How can the "strengths" of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors-and that is how risk gradients are interpreted-so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RR(s). This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. In Terms of the Logarithmic Mean Annual Seismicity Rate and Its Standard Deviation to Present the Gutenberg-Richter Relation

    NASA Astrophysics Data System (ADS)

    Chen, K. P.; Chang, W. Y.; Tsai, Y. B.

    2016-12-01

    The main purpose of this study is to apply an innovative approach to assess the median annual seismicity rates and their dispersions for Taiwan earthquakes in different depth ranges. This approach explicitly represents the Gutenberg-Richter (G-R) relation in terms of both the logarithmic mean annual seismicity rate and its standard deviation, instead of just the arithmetic mean. We use the high-quality seismicity data obtained by the Institute of Earth Sciences (IES) and the Central Weather Bureau (CWB) in an earthquake catalog with homogenized moment magnitudes from 1975 to 2014 for our study. The selected data set is shown to be complete for Mw>3.0. We first use it to illustrate the merits of our new approach for dampening the influence of spuriously large or small event numbers in individual years on the determination of median annual seismicity rate and its standard deviation. We further show that the logarithmic annual seismicity rates indeed possess a well-behaved lognormal distribution. The final results are summarized as follows: log10N=5.75-0.90Mw+/-(0.245-0.01Mw) for focal depth 0 300 km; log10N=5.78-0.94Mw+/-(0.195+0.01Mw) for focal depth 0-35 km; log10N=4.72-0.89Mw+/-(-0.075+0.075Mw) for focal depth 35-70 km; and log10N=4.69-0.88Mw+/-(-0.47+0.16Mw) for focal depth 70-300 km. Above results show distinctly different values for the parameters a and b in the G-R relations for Taiwan earthquakes in different depth ranges. These analytical equations can be readily used for comprehensive probabilistic seismic hazard assessment. Furthermore, a numerical table on the corresponding median annual seismicity rates and their upper and lower bounds at median +/- one standard deviation levels, as calculated from above analytical equations, is presented at the end. This table offers an overall glance of the estimated median annual seismicity rates and their dispersions for Taiwan earthquakes of various magnitudes and focal depths. It is interesting to point out that

  14. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP)

    PubMed Central

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472

  15. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  16. Development and operation of a quality assurance system for deviations from standard operating procedures in a clinical cell therapy laboratory.

    PubMed

    McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J

    2003-01-01

    Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in

  17. Inverse correlation between the standard deviation of R-R intervals in supine position and the simplified menopausal index in women with climacteric symptoms.

    PubMed

    Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio

    2014-06-01

    Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P < 0.01, 0.05, and 0.001, respectively) decreased in women with climacteric symptoms. There was a negative correlation between the standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.

  18. U.S. Navy Marine Climatic Atlas of the World. Volume IX. World-Wide Means and Standard Deviations

    DTIC Science & Technology

    1981-10-01

    TITLE (..d SobtII,) S. TYPE OF REPORT & PERIOD COVERED U. S. Navy Marine Climatic Atlas of the World Volume IX World-wide Means and Standard Reference...Ives the best estimate of the population standard deviations. The means, , are com~nuted from: EX IIN I 90 80 70 60" 50’ 40, 30 20 10 0 1070 T- VErr ...or 10%, whichever is greater Since the mean ice limit approximates the minus two de l temperature isopleth, this analyzed lower limit was Wave Heights

  19. Nutrient intake values (NIVs): a recommended terminology and framework for the derivation of values.

    PubMed

    King, Janet C; Vorster, Hester H; Tome, Daniel G

    2007-03-01

    Although most countries and regions around the world set recommended nutrient intake values for their populations, there is no standardized terminology or framework for establishing these standards. Different terms used for various components of a set of dietary standards are described in this paper and a common set of terminology is proposed. The recommended terminology suggests that the set of values be called nutrient intake values (NIVs) and that the set be composed of three different values. The average nutrient requirement (ANR) reflects the median requirement for a nutrient in a specific population. The individual nutrient level (INLx) is the recommended level of nutrient intake for all healthy people in the population, which is set at a certain level x above the mean requirement. For example, a value set at 2 standard deviations above the mean requirement would cover the needs of 98% of the population and would be INL98. The third component of the NIVs is an upper nutrient level (UNL), which is the highest level of daily nutrient intake that is likely to pose no risk of adverse health effects for almost all individuals in a specified life-stage group. The proposed framework for deriving a set of NIVs is based on a statistical approach for determining the midpoint of a distribution of requirements for a set of nutrients in a population (the ANR), the standard deviation of the requirements, and an individual nutrient level that assures health at some point above the mean, e.g., 2 standard deviations. Ideally, a second set of distributions of risk of excessive intakes is used as the basis for a UNL.

  20. Incidence of Artifacts and Deviating Values in Research Data Obtained from an Anesthesia Information Management System in Children.

    PubMed

    Hoorweg, Anne-Lee J; Pasma, Wietze; van Wolfswinkel, Leo; de Graaff, Jurgen C

    2018-02-01

    Vital parameter data collected in anesthesia information management systems are often used for clinical research. The validity of this type of research is dependent on the number of artifacts. In this prospective observational cohort study, the incidence of artifacts in anesthesia information management system data was investigated in children undergoing anesthesia for noncardiac procedures. Secondary outcomes included the incidence of artifacts among deviating and nondeviating values, among the anesthesia phases, and among different anesthetic techniques. We included 136 anesthetics representing 10,236 min of anesthesia time. The incidence of artifacts was 0.5% for heart rate (95% CI: 0.4 to 0.7%), 1.3% for oxygen saturation (1.1 to 1.5%), 7.5% for end-tidal carbon dioxide (6.9 to 8.0%), 5.0% for noninvasive blood pressure (4.0 to 6.0%), and 7.3% for invasive blood pressure (5.9 to 8.8%). The incidence of artifacts among deviating values was 3.1% for heart rate (2.1 to 4.4%), 10.8% for oxygen saturation (7.6 to 14.8%), 14.1% for end-tidal carbon dioxide (13.0 to 15.2%), 14.4% for noninvasive blood pressure (10.3 to 19.4%), and 38.4% for invasive blood pressure (30.3 to 47.1%). Not all values in anesthesia information management systems are valid. The incidence of artifacts stored in the present pediatric anesthesia practice was low for heart rate and oxygen saturation, whereas noninvasive and invasive blood pressure and end-tidal carbon dioxide had higher artifact incidences. Deviating values are more often artifacts than values in a normal range, and artifacts are associated with the phase of anesthesia and anesthetic technique. Development of (automatic) data validation systems or solutions to deal with artifacts in data is warranted.

  1. [Psychopathological characteristics in patients with deviation of nasal septum: a preliminary analysis].

    PubMed

    Li, W T; Chen, X Z; Tu, W J; Huang, Z Z; Chang, L H; Wang, J; Zhang, G H

    2016-09-07

    Objective: To investigate the psychopathological characteristics in patients with deviation of nasal septum. Methods: Between May 2015 and December 2015, fourty-four patients with deviated nasal septum and 37 patients with vocal cord polyp as control were included in this study. Psychological characteristics were evaluated by a series of questionnaire instruments including symptom checklist-90 (SCL-90), self-rating depression scale (SDS) and self-rating anxiety scale (SAS). Visual analogue scale (VAS) and rhinomanometry through front nostril were used to evaluate nasal symptom. The correlation between psychological characteristics and nasal symptom was evaluated. SPSS 20.0 software was used to analyze the data. Results: The SCL-90 score in nasal septal deviation group was 130.4±48.3. The total score and total average score of SCL-90 had no significant difference between nasal septal deviation group and the Chinese standard or control group( t value was 0.469, 0.112, 1.575, 1.564, respectively, all P >0.05). The scores of somatization, depression and anxiety factors in nasal septal deviation group were higher than control group ( t value was 2.380, 2.133, 1.969, respectively, all P <0.05). The proportion of positive patients in these three factors between nasal septal deviation group and control group had significant differences (χ 2 value was 11.585, 9.610, 5.429, respectively, all P <0.05). The scores of SDS and SAS in nasal septal deviation group were 46.0±10.6 and 43.0±10.2, which were higher than that in the Chinese standard and control group ( t value was 5.342, 6.236, 1.476, 3.013, respectively, all P <0.05). There were 9 patients companying with depression or anxiety (20.5%, 20.5%, respectively) and 5 patients companying with depression and anxiety in nasal septal deviation group (11.4%). There were positive correlation not only between the scores of SDS and the depression factor of SCL-90 but also between the scores of SAS and the anxiety factor of SCL

  2. Standard Deviation of Spatially-Averaged Surface Cross Section Data from the TRMM Precipitation Radar

    NASA Technical Reports Server (NTRS)

    Meneghini, Robert; Jones, Jeffrey A.

    2010-01-01

    We investigate the spatial variability of the normalized radar cross section of the surface (NRCS or Sigma(sup 0)) derived from measurements of the TRMM Precipitation Radar (PR) for the period from 1998 to 2009. The purpose of the study is to understand the way in which the sample standard deviation of the Sigma(sup 0) data changes as a function of spatial resolution, incidence angle, and surface type (land/ocean). The results have implications regarding the accuracy by which the path integrated attenuation from precipitation can be inferred by the use of surface scattering properties.

  3. Deviation from zeitgeist and motivation in the intergenerational transmission of individualistic and collectivistic values in East Germany and Shanghai, China.

    PubMed

    Schönpflug, Ute; Yan, Song

    2014-01-01

    Intergenerational intrafamilial transmission is a process by which acquired information passes from parent to offspring. The authors examined mechanisms of intergenerational transmission of individualistic and collectivistic values in 216 families with 1 adolescent child in 2 societies: East Germany and the Shanghai region in China. To clarify the impact of transmission from mother and father to son or daughter, this study analyzed the filter model by U. Schönpflug and L. Bilz (2009), including zeitgeist concerning value climate in the social context, each family member's deviation from the zeitgeist, and the familial motivation to transmit. The 2-dimensional structure (individualism and collectivism) of 10 values of the Portrait Value Questionnaire (Schwartz, Lehmann, & Rocca, 1999) differed somewhat in the 2 regions for adolescents and their fathers, but not for mothers. In East Germany, no significant direct transmission of value orientation was observed, whereas in Shanghai, fathers transmitted individualism and collectivism values. Family motivation impacted significantly on the child's value orientation in both regions. The zeitgeist measure had no significant influence on the transmission process whereas deviation from zeitgeist did. The gender of the child determined the level and transmission of collectivism, but not the transfer of individualism.

  4. Improved differentiation between hepatic hemangioma and metastases on diffusion-weighted MRI by measurement of standard deviation of apparent diffusion coefficient.

    PubMed

    Hardie, Andrew D; Egbert, Robert E; Rissing, Michael S

    2015-01-01

    Diffusion-weighted magnetic resonance imaging (DW-MR) can be useful in the differentiation of hemangiomata from liver metastasis, but improved methods other than by mean apparent diffusion coefficient (mADC) are needed. A retrospective review identified 109 metastatic liver lesions and 86 hemangiomata in 128 patients who had undergone DW-MR. For each lesion, mADC and the standard deviation of the mean ADC (sdADC) were recorded and compared by receiver operating characteristic analysis. Mean mADC was higher in benign hemangiomata (1.52±0.12 mm(2)/s) than in liver metastases (1.33±0.18 mm(2)/s), but there was significant overlap in values. The mean sdADC was lower in hemangiomata (101±17 mm(2)/s) than metastases (245±25 mm(2)/s) and demonstrated no overlap in values, which was significantly different (P<.0001). Hemangiomata may be better able to be differentiated from liver metastases on the basis of sdADC than by mADC, although further studies are needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Relationship between consecutive deterioration of mean deviation value and progression of visual field defect in open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Takeda, Ryuji; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between consecutive deterioration of mean deviation (MD) value and glaucomatous visual field (VF) progression in open-angle glaucoma (OAG), including primary OAG and normal tension glaucoma. The subjects of the study were patients undergoing treatment for OAG who had performed VF tests at least 10 times with a Humphrey field analyzer (SITA standard, C30-2 program). The VF progression was defined by a significantly negative MD slope (MD slope worsening) at the final VF test during the follow-up period. The relationship between the MD slope worsening and the consecutive deterioration of MD value were retrospectively analyzed. A total of 165 eyes of 165 patients were included in the analysis. Significant progression of VF defects was observed in 72 eyes of 72 patients (43.6%), while no significant progression was evident in 93 eyes of 93 patients (56.4%). There was significant relationship between the frequency of consecutive deterioration of MD value and MD slope worsening (P<0.0001, Cochran-Armitage trend test). A significant association was observed for MD slope worsening in the eyes with three (odds ratio: 2.1, P=0.0224) and four (odds ratio: 3.6, P=0.0008) consecutive deterioration of MD value in multiple logistic regression analysis, but no significant association in the eyes with two consecutive deterioration (odds ratio: 1.1, P=0.8282). The eyes with VF progression had significantly lower intraocular pressure reduction rate (P<0.01). This retrospective study has shown that three or more consecutive deterioration of MD value might be a predictor to future significant MD slope worsening in OAG.

  6. A passive autofocus system by using standard deviation of the image on a liquid lens

    NASA Astrophysics Data System (ADS)

    Rasti, Pejman; Kesküla, Arko; Haus, Henry; Schlaak, Helmut F.; Anbarjafari, Gholamreza; Aabloo, Alvo; Kiefer, Rudolf

    2015-04-01

    Today most of applications have a small camera such as cell phones, tablets and medical devices. A micro lens is required in order to reduce the size of the devices. In this paper an auto focus system is used in order to find the best position of a liquid lens without any active components such as ultrasonic or infrared. In fact a passive auto focus system by using standard deviation of the images on a liquid lens which consist of a Dielectric Elastomer Actuator (DEA) membrane between oil and water is proposed.

  7. Tree value conversion standards revisited

    Treesearch

    Paul S. DeBald; Martin E. Dale; Martin E. Dale

    1991-01-01

    Updated tree value conversion standards (TVCS) are presented for 12 important hardwood species of the oak-hickory forest. These updated standards-developed for each species by butt-log grade, merchantable height, and diameter at breast height-reflect the changes in lumber prices and in conversion costs which have occurred since 1976 when the original TVCS were...

  8. Analysis of using the tongue deviation angle as a warning sign of a stroke

    PubMed Central

    2012-01-01

    Background The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. Methods In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. Results The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student’s t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients

  9. Analysis of using the tongue deviation angle as a warning sign of a stroke.

    PubMed

    Wei, Ching-Chuan; Huang, Shu-Wen; Hsu, Sheng-Lin; Chen, Hsing-Chung; Chen, Jong-Shin; Liang, Hsinying

    2012-08-21

    The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student's t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With

  10. Detection of severe storm signatures in loblolly pine using seven-year periodic standardized averages and standard deviations

    Treesearch

    Stevenson Douglas; Thomas Hennessey; Thomas Lynch; Giulia Caterina; Rodolfo Mota; Robert Heineman; Randal Holeman; Dennis Wilson; Keith Anderson

    2016-01-01

    A loblolly pine plantation near Eagletown, Oklahoma was used to test standardized tree ring widths in detecting snow and ice storms. Widths of two rings immediately following suspected storms were standardized against widths of seven rings following the storm (Stan1 and Stan2). Values of Stan1 less than -0.900 predict a severe (usually ice) storm when Stan 2 is less...

  11. Using the Standard Deviation of a Region of Interest in an Image to Estimate Camera to Emitter Distance

    PubMed Central

    Cano-García, Angel E.; Lazaro, José Luis; Infante, Arturo; Fernández, Pedro; Pompa-Chacón, Yamilet; Espinoza, Felipe

    2012-01-01

    In this study, a camera to infrared diode (IRED) distance estimation problem was analyzed. The main objective was to define an alternative to measures depth only using the information extracted from pixel grey levels of the IRED image to estimate the distance between the camera and the IRED. In this paper, the standard deviation of the pixel grey level in the region of interest containing the IRED image is proposed as an empirical parameter to define a model for estimating camera to emitter distance. This model includes the camera exposure time, IRED radiant intensity and the distance between the camera and the IRED. An expression for the standard deviation model related to these magnitudes was also derived and calibrated using different images taken under different conditions. From this analysis, we determined the optimum parameters to ensure the best accuracy provided by this alternative. Once the model calibration had been carried out, a differential method to estimate the distance between the camera and the IRED was defined and applied, considering that the camera was aligned with the IRED. The results indicate that this method represents a useful alternative for determining the depth information. PMID:22778608

  12. Using the standard deviation of a region of interest in an image to estimate camera to emitter distance.

    PubMed

    Cano-García, Angel E; Lazaro, José Luis; Infante, Arturo; Fernández, Pedro; Pompa-Chacón, Yamilet; Espinoza, Felipe

    2012-01-01

    In this study, a camera to infrared diode (IRED) distance estimation problem was analyzed. The main objective was to define an alternative to measures depth only using the information extracted from pixel grey levels of the IRED image to estimate the distance between the camera and the IRED. In this paper, the standard deviation of the pixel grey level in the region of interest containing the IRED image is proposed as an empirical parameter to define a model for estimating camera to emitter distance. This model includes the camera exposure time, IRED radiant intensity and the distance between the camera and the IRED. An expression for the standard deviation model related to these magnitudes was also derived and calibrated using different images taken under different conditions. From this analysis, we determined the optimum parameters to ensure the best accuracy provided by this alternative. Once the model calibration had been carried out, a differential method to estimate the distance between the camera and the IRED was defined and applied, considering that the camera was aligned with the IRED. The results indicate that this method represents a useful alternative for determining the depth information.

  13. The recursive combination filter approach of pre-processing for the estimation of standard deviation of RR series.

    PubMed

    Mishra, Alok; Swati, D

    2015-09-01

    Variation in the interval between the R-R peaks of the electrocardiogram represents the modulation of the cardiac oscillations by the autonomic nervous system. This variation is contaminated by anomalous signals called ectopic beats, artefacts or noise which mask the true behaviour of heart rate variability. In this paper, we have proposed a combination filter of recursive impulse rejection filter and recursive 20% filter, with recursive application and preference of replacement over removal of abnormal beats to improve the pre-processing of the inter-beat intervals. We have tested this novel recursive combinational method with median method replacement to estimate the standard deviation of normal to normal (SDNN) beat intervals of congestive heart failure (CHF) and normal sinus rhythm subjects. This work discusses the improvement in pre-processing over single use of impulse rejection filter and removal of abnormal beats for heart rate variability for the estimation of SDNN and Poncaré plot descriptors (SD1, SD2, and SD1/SD2) in detail. We have found the 22 ms value of SDNN and 36 ms value of SD2 descriptor of Poincaré plot as clinical indicators in discriminating the normal cases from CHF cases. The pre-processing is also useful in calculation of Lyapunov exponent which is a nonlinear index as Lyapunov exponents calculated after proposed pre-processing modified in a way that it start following the notion of less complex behaviour of diseased states.

  14. Efficient Estimation of the Standardized Value

    ERIC Educational Resources Information Center

    Longford, Nicholas T.

    2009-01-01

    We derive an estimator of the standardized value which, under the standard assumptions of normality and homoscedasticity, is more efficient than the established (asymptotically efficient) estimator and discuss its gains for small samples. (Contains 1 table and 3 figures.)

  15. Prognostic implications of mutation-specific QTc standard deviation in congenital long QT syndrome.

    PubMed

    Mathias, Andrew; Moss, Arthur J; Lopes, Coeli M; Barsheshet, Alon; McNitt, Scott; Zareba, Wojciech; Robinson, Jennifer L; Locati, Emanuela H; Ackerman, Michael J; Benhorin, Jesaia; Kaufman, Elizabeth S; Platonov, Pyotr G; Qi, Ming; Shimizu, Wataru; Towbin, Jeffrey A; Michael Vincent, G; Wilde, Arthur A M; Zhang, Li; Goldenberg, Ilan

    2013-05-01

    Individual corrected QT interval (QTc) may vary widely among carriers of the same long QT syndrome (LQTS) mutation. Currently, neither the mechanism nor the implications of this variable penetrance are well understood. To hypothesize that the assessment of QTc variance in patients with congenital LQTS who carry the same mutation provides incremental prognostic information on the patient-specific QTc. The study population comprised 1206 patients with LQTS with 95 different mutations and ≥ 5 individuals who carry the same mutation. Multivariate Cox proportional hazards regression analysis was used to assess the effect of mutation-specific standard deviation of QTc (QTcSD) on the risk of cardiac events (comprising syncope, aborted cardiac arrest, and sudden cardiac death) from birth through age 40 years in the total population and by genotype. Assessment of mutation-specific QTcSD showed large differences among carriers of the same mutations (median QTcSD 45 ms). Multivariate analysis showed that each 20 ms increment in QTcSD was associated with a significant 33% (P = .002) increase in the risk of cardiac events after adjustment for the patient-specific QTc duration and the family effect on QTc. The risk associated with QTcSD was pronounced among patients with long QT syndrome type 1 (hazard ratio 1.55 per 20 ms increment; P<.001), whereas among patients with long QT syndrome type 2, the risk associated with QTcSD was not statistically significant (hazard ratio 0.99; P = .95; P value for QTcSD-by-genotype interaction = .002). Our findings suggest that mutations with a wider variation in QTc duration are associated with increased risk of cardiac events. These findings appear to be genotype-specific, with a pronounced effect among patients with the long QT syndrome type 1 genotype. Copyright © 2013. Published by Elsevier Inc.

  16. Quantifying gait deviations in individuals with rheumatoid arthritis using the Gait Deviation Index.

    PubMed

    Esbjörnsson, A-C; Rozumalski, A; Iversen, M D; Schwartz, M H; Wretenberg, P; Broström, E W

    2014-01-01

    In this study we evaluated the usability of the Gait Deviation Index (GDI), an index that summarizes the amount of deviation in movement from a standard norm, in adults with rheumatoid arthritis (RA). The aims of the study were to evaluate the ability of the GDI to identify gait deviations, assess inter-trial repeatability, and examine the relationship between the GDI and walking speed, physical disability, and pain. Sixty-three adults with RA and 59 adults with typical gait patterns were included in this retrospective case-control study. Following a three-dimensional gait analysis (3DGA), representative gait cycles were selected and GDI scores calculated. To evaluate the effect of walking speed, GDI scores were calculated using both a free-speed and a speed-matched reference set. Physical disability was assessed using the Health Assessment Questionnaire (HAQ) and subjects rated their pain during walking. Adults with RA had significantly increased gait deviations compared to healthy individuals, as shown by lower GDI scores [87.9 (SD = 8.7) vs. 99.4 (SD = 8.3), p < 0.001]. This difference was also seen when adjusting for walking speed [91.7 (SD = 9.0) vs. 99.9 (SD = 8.6), p < 0.001]. It was estimated that a change of ≥ 5 GDI units was required to account for natural variation in gait. There was no evident relationship between GDI and low/high RA-related physical disability and pain. The GDI seems to useful for identifying and summarizing gait deviations in individuals with RA. Thus, we consider that the GDI provides an overall measure of gait deviation that may reflect lower extremity pathology and may help clinicians to understand the impact of RA on gait dynamics.

  17. Correlation of pattern reversal visual evoked potential parameters with the pattern standard deviation in primary open angle glaucoma.

    PubMed

    Kothari, Ruchi; Bokariya, Pradeep; Singh, Ramji; Singh, Smita; Narang, Purvasha

    2014-01-01

    To evaluate whether glaucomatous visual field defect particularly the pattern standard deviation (PSD) of Humphrey visual field could be associated with visual evoked potential (VEP) parameters of patients having primary open angle glaucoma (POAG). Visual field by Humphrey perimetry and simultaneous recordings of pattern reversal visual evoked potential (PRVEP) were assessed in 100 patients with POAG. The stimulus configuration for VEP recordings consisted of the transient pattern reversal method in which a black and white checker board pattern was generated (full field) and displayed on VEP monitor (colour 14″) by an electronic pattern regenerator inbuilt in an evoked potential recorder (RMS EMG EP MARK II). The results of our study indicate that there is a highly significant (P<0.001) negative correlation of P100 amplitude and a statistically significant (P<0.05) positive correlation of N70 latency, P100 latency and N155 latency with the PSD of Humphrey visual field in the subjects of POAG in various age groups as evaluated by Student's t-test. Prolongation of VEP latencies were mirrored by a corresponding increase of PSD values. Conversely, as PSD increases the magnitude of VEP excursions were found to be diminished.

  18. HOW STUDENTS USE VALUES IN DECISION-MAKING.

    ERIC Educational Resources Information Center

    VARENHORST, BARBARA B.

    HIGH SCHOOL STUDENTS ARE EXAMINING AND INTERNALIZING VALUES. THEIR FEAR OF COMMITMENT TO ANYTHING DEVIATING FROM ACCEPTED VALUES MAY HINDER THEIR CLARIFICATION OF PERSONAL GOALS AND VALUES. THE DECISION-MAKING PROCESS SHOULD BE AN IMPORTANT PART OF THE GUIDANCE PROGRAM. STANDARD QUESTIONNAIRES DO NOT PROVIDE INFORMATION ABOUT SPECIFIC FACTORS…

  19. Severe obesity is a limitation for the use of body mass index standard deviation scores in children and adolescents.

    PubMed

    Júlíusson, Pétur B; Roelants, Mathieu; Benestad, Beate; Lekhal, Samira; Danielsen, Yngvild; Hjelmesaeth, Jøran; Hertel, Jens K

    2018-02-01

    We analysed the distribution of the body mass index standard deviation scores (BMI-SDS) in children and adolescents seeking treatment for severe obesity, according to the International Obesity Task Force (IOTF), World Health Organization (WHO) and the national Norwegian Bergen Growth Study (BGS) BMI reference charts and the percentage above the International Obesity Task Force 25 cut-off (IOTF-25). This was a cross-sectional study of 396 children aged four to 17 years, who attended a tertiary care obesity centre in Norway from 2009 to 2015. Their BMI was converted to SDS using the three growth references and expressed as the percentage above IOTF-25. The percentage of body fat was assessed by bioelectrical impedance analysis. Regardless of which BMI reference chart was used, the BMI-SDS was significantly different between the age groups, with a wider range of higher values up to 10 years of age and a more narrow range of lower values thereafter. The distributions of the percentage above IOTF-25 and percentage of body fat were more consistent across age groups. Our findings suggest that it may be more appropriate to use the percentage above a particular BMI cut-off, such as the percentage above IOTF-25, than the IOTF, WHO and BGS BMI-SDS in paediatric patients with severe obesity. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.

    PubMed

    Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan

    2016-12-01

    Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.

  1. Assessing factors that influence deviations between measured and calculated reference evapotranspiration

    NASA Astrophysics Data System (ADS)

    Rodny, Marek; Nolz, Reinhard

    2017-04-01

    Evapotranspiration (ET) is a fundamental component of the hydrological cycle, but challenging to be quantified. Lysimeter facilities, for example, can be installed and operated to determine ET, but they are costly and represent only point measurements. Therefore, lysimeter data are traditionally used to develop, calibrate, and validate models that allow calculating reference evapotranspiration (ET0) based on meteorological data, which can be measured more easily. The standardized form of the well-known FAO Penman-Monteith equation (ASCE-EWRI) is recommended as a standard procedure for estimating ET0 and subsequently plant water requirements. Applied and validated under different climatic conditions, the Penman-Monteith equation is generally known to deliver proper results. On the other hand, several studies documented deviations between measured and calculated ET0 depending on environmental conditions. Potential reasons are, for example, differing or varying surface characteristics of the lysimeter and the location where the weather instruments are placed. Advection of sensible heat (transport of dry and hot air from surrounding areas) might be another reason for deviating ET-values. However, elaborating causal processes is complex and requires comprehensive data of high quality and specific analysis techniques. In order to assess influencing factors, we correlated differences between measured and calculated ET0 with pre-selected meteorological parameters and related system parameters. Basic data were hourly ET0-values from a weighing lysimeter (ET0_lys) with a surface area of 2.85 m2 (reference crop: frequently irrigated grass), weather data (air and soil temperature, relative humidity, air pressure, wind velocity, and solar radiation), and soil water content in different depths. ET0_ref was calculated in hourly time steps according to the standardized procedure after ASCE-EWRI (2005). Deviations between both datasets were calculated as ET0_lys-ET0_ref and

  2. Reassessment of carotid intima-media thickness by standard deviation score in children and adolescents after Kawasaki disease.

    PubMed

    Noto, Nobutaka; Kato, Masataka; Abe, Yuriko; Kamiyama, Hiroshi; Karasawa, Kensuke; Ayusawa, Mamoru; Takahashi, Shori

    2015-01-01

    Previous studies that used carotid ultrasound have been largely conflicting in regards to whether or not patients after Kawasaki disease (KD) have a greater carotid intima-media thickness (CIMT) than controls. To test the hypothesis that there are significant differences between the values of CIMT expressed as absolute values and standard deviation scores (SDS) in children and adolescents after KD and controls, we reviewed 12 published articles regarding CIMT on KD patients and controls. The mean ± SD of absolute CIMT (mm) in the KD patients and controls obtained from each article was transformed to SDS (CIMT-SDS) using age-specific reference values established by Jourdan et al. (J: n = 247) and our own data (N: n = 175), and the results among these 12 articles were compared between the two groups and the references for comparison of racial disparities. There were no significant differences in mean absolute CIMT and mean CIMT-SDS for J between KD patients and controls (0.46 ± 0.06 mm vs. 0.44 ± 0.04 mm, p = 0.133, and 1.80 ± 0.84 vs. 1.25 ± 0.12, p = 0.159, respectively). However, there were significant differences in mean CIMT-SDS for N between KD patients and controls (0.60 ± 0.71 vs. 0.01 ± 0.65, p = 0.042). When we assessed the nine articles on Asian subjects, the difference of CIMT-SDS between the two groups was invariably significant only for N (p = 0.015). Compared with the reference values, CIMT-SDS of controls was within the normal range at a rate of 41.6 % for J and 91.6 % for N. These results indicate that age- and race-specific reference values for CIMT are mandatory for performing accurate assessment of the vascular status in healthy children and adolescents, particularly in those after KD considered at increased long-term cardiovascular risk.

  3. [Value(s)].

    PubMed

    Vanbelle, G

    2006-01-01

    After a short explanation of the word value, the (cultural) value of teeth, the economic evaluation of dentistry and the payment criteria are being presented. The specific situation of health care as a service which deviates in quite a few aspects from the standard demand-supply model is being pointed out. Attention is drawn to key characteristics of the liberal professions such as the obligation to perform to the best of one's ability, not to a specific result. Function classification appears to offer possibilities for cataloguing the wide variation in practice settings. The well-known wage calculation of Professor De Lembre is being reviewed. Subsequently the analysis of cost variation and induced demand by extra services and profile shaping is being elaborated. Cost-benefit-analysis is the concluding item.

  4. Min and Max Exponential Extreme Interval Values and Statistics

    ERIC Educational Resources Information Center

    Jance, Marsha; Thomopoulos, Nick

    2009-01-01

    The extreme interval values and statistics (expected value, median, mode, standard deviation, and coefficient of variation) for the smallest (min) and largest (max) values of exponentially distributed variables with parameter ? = 1 are examined for different observation (sample) sizes. An extreme interval value g[subscript a] is defined as a…

  5. The average direct current offset values for small digital audio recorders in an acoustically consistent environment.

    PubMed

    Koenig, Bruce E; Lacey, Douglas S

    2014-07-01

    In this research project, nine small digital audio recorders were tested using five sets of 30-min recordings at all available recording modes, with consistent audio material, identical source and microphone locations, and identical acoustic environments. The averaged direct current (DC) offset values and standard deviations were measured for 30-sec and 1-, 2-, 3-, 6-, 10-, 15-, and 30-min segments. The research found an inverse association between segment lengths and the standard deviation values and that lengths beyond 30 min may not meaningfully reduce the standard deviation values. This research supports previous studies indicating that measured averaged DC offsets should only be used for exclusionary purposes in authenticity analyses and exhibit consistent values when the general acoustic environment and microphone/recorder configurations were held constant. Measured average DC offset values from exemplar recorders may not be directly comparable to those of submitted digital audio recordings without exactly duplicating the acoustic environment and microphone/recorder configurations. © 2014 American Academy of Forensic Sciences.

  6. Standard deviation of the mean and other time series properties of voltages measured with a digital lock-in amplifier

    NASA Astrophysics Data System (ADS)

    Witt, Thomas J.; Fletcher, N. E.

    2010-10-01

    We investigate some statistical properties of ac voltages from a white noise source measured with a digital lock-in amplifier equipped with finite impulse response output filters which introduce correlations between successive voltage values. The main goal of this work is to propose simple solutions to account for correlations when calculating the standard deviation of the mean (SDM) for a sequence of measurement data acquired using such an instrument. The problem is treated by time series analysis based on a moving average model of the filtering process. Theoretical expressions are derived for the power spectral density (PSD), the autocorrelation function, the equivalent noise bandwidth and the Allan variance; all are related to the SDM. At most three parameters suffice to specify any of the above quantities: the filter time constant, the time between successive measurements (both set by the lock-in operator) and the PSD of the white noise input, h0. Our white noise source is a resistor so that the PSD is easily calculated; there are no free parameters. Theoretical expressions are checked against their respective sample estimates and, with the exception of two of the bandwidth estimates, agreement to within 11% or better is found.

  7. Opposite associations of age-dependent insulin-like growth factor-I standard deviation scores with nutritional state in normal weight and obese subjects.

    PubMed

    Schneider, Harald Jörn; Saller, Bernhard; Klotsche, Jens; März, Winfried; Erwa, Wolfgang; Wittchen, Hans-Ullrich; Stalla, Günter Karl

    2006-05-01

    Insulin-like growth factor-I (IGF-I) has been suggested to be a prognostic marker for the development of cancer and, more recently, cardiovascular disease. These diseases are closely linked to obesity, but reports of the association of IGF-I with measures of obesity are divergent. In this study, we assessed the association of age-dependent IGF-I standard deviation scores with body mass index (BMI) and intra-abdominal fat accumulation in a large population. A cross-sectional, epidemiological study. IGF-I levels were measured with an automated chemiluminescence assay system in 6282 patients from the DETECT study. Weight, height, and waist and hip circumference were measured according to the written instructions. Standard deviation scores (SDS), correcting IGF-I levels for age, were calculated and were used for further analyses. An inverse U-shaped association of IGF-I SDS with BMI, waist circumference, and the ratio of waist circumference to height was found. BMI was positively associated with IGF-I SDS in normal weight subjects, and negatively associated in obese subjects. The highest mean IGF-I SDS were seen at a BMI of 22.5-25 kg/m2 in men (+0.08), and at a BMI of 27.5-30 kg/m2 in women (+0.21). Multiple linear regression models, controlling for different diseases, medications and risk conditions, revealed a significant negative association of BMI with IGF-I SDS. BMI contributed most to the additional explained variance to the other health conditions. IGF-I standard deviation scores are decreased in obesity and underweight subjects. These interactions should be taken into account when analyzing the association of IGF-I with diseases and risk conditions.

  8. A Taxonomy of Delivery and Documentation Deviations During Delivery of High-Fidelity Simulations.

    PubMed

    McIvor, William R; Banerjee, Arna; Boulet, John R; Bekhuis, Tanja; Tseytlin, Eugene; Torsher, Laurence; DeMaria, Samuel; Rask, John P; Shotwell, Matthew S; Burden, Amanda; Cooper, Jeffrey B; Gaba, David M; Levine, Adam; Park, Christine; Sinz, Elizabeth; Steadman, Randolph H; Weinger, Matthew B

    2017-02-01

    We developed a taxonomy of simulation delivery and documentation deviations noted during a multicenter, high-fidelity simulation trial that was conducted to assess practicing physicians' performance. Eight simulation centers sought to implement standardized scenarios over 2 years. Rules, guidelines, and detailed scenario scripts were established to facilitate reproducible scenario delivery; however, pilot trials revealed deviations from those rubrics. A taxonomy with hierarchically arranged terms that define a lack of standardization of simulation scenario delivery was then created to aid educators and researchers in assessing and describing their ability to reproducibly conduct simulations. Thirty-six types of delivery or documentation deviations were identified from the scenario scripts and study rules. Using a Delphi technique and open card sorting, simulation experts formulated a taxonomy of high-fidelity simulation execution and documentation deviations. The taxonomy was iteratively refined and then tested by 2 investigators not involved with its development. The taxonomy has 2 main classes, simulation center deviation and participant deviation, which are further subdivided into as many as 6 subclasses. Inter-rater classification agreement using the taxonomy was 74% or greater for each of the 7 levels of its hierarchy. Cohen kappa calculations confirmed substantial agreement beyond that expected by chance. All deviations were classified within the taxonomy. This is a useful taxonomy that standardizes terms for simulation delivery and documentation deviations, facilitates quality assurance in scenario delivery, and enables quantification of the impact of deviations upon simulation-based performance assessment.

  9. Spectral combination of spherical gravitational curvature boundary-value problems

    NASA Astrophysics Data System (ADS)

    PitoÅák, Martin; Eshagh, Mehdi; Šprlák, Michal; Tenzer, Robert; Novák, Pavel

    2018-04-01

    Four solutions of the spherical gravitational curvature boundary-value problems can be exploited for the determination of the Earth's gravitational potential. In this article we discuss the combination of simulated satellite gravitational curvatures, i.e., components of the third-order gravitational tensor, by merging these solutions using the spectral combination method. For this purpose, integral estimators of biased- and unbiased-types are derived. In numerical studies, we investigate the performance of the developed mathematical models for the gravitational field modelling in the area of Central Europe based on simulated satellite measurements. Firstly, we verify the correctness of the integral estimators for the spectral downward continuation by a closed-loop test. Estimated errors of the combined solution are about eight orders smaller than those from the individual solutions. Secondly, we perform a numerical experiment by considering the Gaussian noise with the standard deviation of 6.5× 10-17 m-1s-2 in the input data at the satellite altitude of 250 km above the mean Earth sphere. This value of standard deviation is equivalent to a signal-to-noise ratio of 10. Superior results with respect to the global geopotential model TIM-r5 are obtained by the spectral downward continuation of the vertical-vertical-vertical component with the standard deviation of 2.104 m2s-2, but the root mean square error is the largest and reaches 9.734 m2s-2. Using the spectral combination of all gravitational curvatures the root mean square error is more than 400 times smaller but the standard deviation reaches 17.234 m2s-2. The combination of more components decreases the root mean square error of the corresponding solutions while the standard deviations of the combined solutions do not improve as compared to the solution from the vertical-vertical-vertical component. The presented method represents a weight mean in the spectral domain that minimizes the root mean square error

  10. Standard operating procedures (SOPs): reason for, types of, adequacy, approval, and deviations from and revisions to.

    PubMed

    Isaman, V; Thelin, R

    1995-09-01

    Standard Operating Procedures (SOPs) are required in order to comply with the Good Laboratory Practice Standards (GLPS) as promulgated in the Federal Insecticide, Fungicide and Rodenticide Act (FIFRA) 40 CFR Part 160. Paragraph 160.81 (a) states: "A testing facility shall have standard operating procedures in writing setting forth study methods that management is satisfied are adequate to insure the quality and integrity of the data generated in the course of a study." Types of SOPs include administrative and personnel, analyses, substances, quality assurance and records, test system, equipment, and field related. All SOPs must be adequate in scope to describe the function in sufficient detail such that the study data are reproducible. All SOPs must be approved by a management level as described in a corporate organization chart. Signatures for SOP responsibility, authorship, and Quality Assurance review adds strength and accountability to the SOP. In the event a procedure or method is performed differently from what is stated in the SOP, an SOP deviation is necessary. As methods and procedures are improved, SOP revisions are necessary to maintain SOP adequacy and applicability. The replaced SOP is put into a historical SOP file and all copies of the replaced SOPs are destroyed.

  11. Complexities of follicle deviation during selection of a dominant follicle in Bos taurus heifers.

    PubMed

    Ginther, O J; Baldrighi, J M; Siddiqui, M A R; Araujo, E R

    2016-11-01

    Follicle deviation during a follicular wave is a continuation in growth rate of the dominant follicle (F1) and decreased growth rate of the largest subordinate follicle (F2). The reliability of using an F1 of 8.5 mm to represent the beginning of expected deviation for experimental purposes during waves 1 and 2 (n = 26 per wave) was studied daily in heifers. Each wave was subgrouped as follows: standard subgroup (F1 larger than F2 for 2 days preceding deviation and F2 > 7.0 mm on the day of deviation), undersized subgroup (F2 did not attain 7.0 mm by the day of deviation), and switched subgroup (F2 larger than F1 at least once on the 2 days before or on the day of deviation). For each wave, mean differences in diameter between F1 and F2 changed abruptly at expected deviation in the standard subgroup but began 1 day before expected deviation in the undersized and switched subgroups. Concentrations of FSH in the wave-stimulating FSH surge and an increase in LH centered on expected deviation did not differ among subgroups. Results for each wave indicated that (1) expected deviation (F1, 8.5 mm) was a reliable representation of actual deviation in the standard subgroup but not in the undersized and switched subgroups; (2) concentrations of the gonadotropins normalized to expected deviation were similar among the three subgroups, indicating that the day of deviation was related to diameter of F1 and not F2; and (3) defining an expected day of deviation for experimental use should consider both diameter of F1 and the characteristics of deviation. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Minimizing the Standard Deviation of Spatially Averaged Surface Cross-Sectional Data from the Dual-Frequency Precipitation Radar

    NASA Technical Reports Server (NTRS)

    Meneghini, Robert; Kim, Hyokyung

    2016-01-01

    For an airborne or spaceborne radar, the precipitation-induced path attenuation can be estimated from the measurements of the normalized surface cross section, sigma 0, in the presence and absence of precipitation. In one implementation, the mean rain-free estimate and its variability are found from a lookup table (LUT) derived from previously measured data. For the dual-frequency precipitation radar aboard the global precipitation measurement satellite, the nominal table consists of the statistics of the rain-free 0 over a 0.5 deg x 0.5 deg latitude-longitude grid using a three-month set of input data. However, a problem with the LUT is an insufficient number of samples in many cells. An alternative table is constructed by a stepwise procedure that begins with the statistics over a 0.25 deg x 0.25 deg grid. If the number of samples at a cell is too few, the area is expanded, cell by cell, choosing at each step that cell that minimizes the variance of the data. The question arises, however, as to whether the selected region corresponds to the smallest variance. To address this question, a second type of variable-averaging grid is constructed using all possible spatial configurations and computing the variance of the data within each region. Comparisons of the standard deviations for the fixed and variable-averaged grids are given as a function of incidence angle and surface type using a three-month set of data. The advantage of variable spatial averaging is that the average standard deviation can be reduced relative to the fixed grid while satisfying the minimum sample requirement.

  13. Perception of midline deviations in smile esthetics by laypersons

    PubMed Central

    Ferreira, Jamille Barros; da Silva, Licínio Esmeraldo; Caetano, Márcia Tereza de Oliveira; da Motta, Andrea Fonseca Jardim; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson

    2016-01-01

    ABSTRACT Objective: To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. Methods: An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student’s t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Results: Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Conclusions: Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation. PMID:28125140

  14. Perception of midline deviations in smile esthetics by laypersons.

    PubMed

    Ferreira, Jamille Barros; Silva, Licínio Esmeraldo da; Caetano, Márcia Tereza de Oliveira; Motta, Andrea Fonseca Jardim da; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson

    2016-01-01

    To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student's t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation.

  15. Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI.

    PubMed

    Dyverfeldt, Petter; Sigfridsson, Andreas; Kvitting, John-Peder Escobar; Ebbers, Tino

    2006-10-01

    Turbulent flow, characterized by velocity fluctuations, is a contributing factor to the pathogenesis of several cardiovascular diseases. A clinical noninvasive tool for assessing turbulence is lacking, however. It is well known that the occurrence of multiple spin velocities within a voxel during the influence of a magnetic gradient moment causes signal loss in phase-contrast magnetic resonance imaging (PC-MRI). In this paper a mathematical derivation of an expression for computing the standard deviation (SD) of the blood flow velocity distribution within a voxel is presented. The SD is obtained from the magnitude of PC-MRI signals acquired with different first gradient moments. By exploiting the relation between the SD and turbulence intensity (TI), this method allows for quantitative studies of turbulence. For validation, the TI in an in vitro flow phantom was quantified, and the results compared favorably with previously published laser Doppler anemometry (LDA) results. This method has the potential to become an important tool for the noninvasive assessment of turbulence in the arterial tree.

  16. Lack of sensitivity of staffing for 8-hour sessions to standard deviation in daily actual hours of operating room time used for surgeons with long queues.

    PubMed

    Pandit, Jaideep J; Dexter, Franklin

    2009-06-01

    At multiple facilities including some in the United Kingdom's National Health Service, the following are features of many surgical-anesthetic teams: i) there is sufficient workload for each operating room (OR) list to almost always be fully scheduled; ii) the workdays are organized such that a single surgeon is assigned to each block of time (usually 8 h); iii) one team is assigned per block; and iv) hardly ever would a team "split" to do cases in more than one OR simultaneously. We used Monte-Carlo simulation using normal and Weibull distributions to estimate the times to complete lists of cases scheduled into such 8 h sessions. For each combination of mean and standard deviation, inefficiencies of use of OR time were determined for 10 h versus 8 h of staffing. When the mean actual hours of OR time used averages < or = 8 h 25 min, 8 h of staffing has higher OR efficiency than 10 h for all combinations of standard deviation and relative cost of over-run to under-run. When mean > or = 8 h 50 min, 10 h staffing has higher OR efficiency. For 8 h 25 min < mean < 8 h 50 min, the economic break-even point depends on conditions. For example, break-even is: (a) 8 h 27 min for Weibull, standard deviation of 60 min and relative cost of over-run to under-run of 2.0 versus (b) 8 h 48 min for normal, standard deviation of 0 min and relative cost ratio of 1.50. Although the simplest decision rule would be to staff for 8 h if the mean workload is < or = 8 h 40 min and to staff for 10 h otherwise, performance was poor. For example, for the Weibull distribution with mean 8 h 40 min, standard deviation 60 min, and relative cost ratio of 2.00, the inefficiency of use of OR time would be 34% larger if staffing were planned for 8 h instead of 10 h. For surgical teams with 8 h sessions, use the following decision rule for anesthesiology and OR nurse staffing. If actual hours of OR time used averages < or = 8 h 25 min, plan 8 h staffing. If average > or = 8 h 50 min, plan 10 h staffing

  17. MO-F-CAMPUS-T-03: Data Driven Approaches for Determination of Treatment Table Tolerance Values for Record and Verification Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, N; DiCostanzo, D; Fullenkamp, M

    2015-06-15

    Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations weremore » computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.« less

  18. [Growth standardized values and curves based on weight, length/height and head circumference for Chinese children under 7 years of age].

    PubMed

    Li, Hui

    2009-03-01

    To construct the growth standardized data and curves based on weight, length/height, head circumference for Chinese children under 7 years of age. Random cluster sampling was used. The fourth national growth survey of children under 7 years in the nine cities (Beijing, Harbin, Xi'an, Shanghai, Nanjing, Wuhan, Fuzhou, Guangzhou and Kunming) of China was performed in 2005 and from this survey, data of 69 760 urban healthy boys and girls were used to set up the database for weight-for-age, height-for-age (length was measured for children under 3 years) and head circumference-for-age. Anthropometric data were ascribed to rigorous methods of data collection and standardized procedures across study sites. LMS method based on BOX-COX normal transformation and cubic splines smoothing technique was chosen for fitting the raw data according to study design and data features, and standardized values of any percentile and standard deviation were obtained by the special formulation of L, M and S parameters. Length-for-age and height-for-age standards were constructed by fitting the same model but the final curves reflected the 0.7 cm average difference between these two measurements. A set of systematic diagnostic tools was used to detect possible biases in estimated percentiles or standard deviation curves, including chi2 test, which was used for reference to evaluate to the goodness of fit. The 3rd, 10th, 25th, 50th, 75th, 90th, 97th smoothed percentiles and -3, -2, -1, 0, +1, +2, +3 SD values and curves of weight-for-age, length/height-for-age and head circumference-for-age for boys and girls aged 0-7 years were made out respectively. The Chinese child growth charts was slightly higher than the WHO child growth standards. The newly established growth charts represented the growth level of healthy and well-nourished Chinese children. The sample size was very large and national, the data were high-quality and the smoothing method was internationally accepted. The new Chinese

  19. Utility of shear wave elastography to detect papillary thyroid carcinoma in thyroid nodules: efficacy of the standard deviation elasticity.

    PubMed

    Kim, Hye Jeong; Kwak, Mi Kyung; Choi, In Ho; Jin, So-Young; Park, Hyeong Kyu; Byun, Dong Won; Suh, Kyoil; Yoo, Myung Hi

    2018-02-23

    The aim of this study was to address the role of the elasticity index as a possible predictive marker for detecting papillary thyroid carcinoma (PTC) and quantitatively assess shear wave elastography (SWE) as a tool for differentiating PTC from benign thyroid nodules. One hundred and nineteen patients with thyroid nodules undergoing SWE before ultrasound-guided fine needle aspiration and core needle biopsy were analyzed. The mean (EMean), minimum (EMin), maximum (EMax), and standard deviation (ESD) of SWE elasticity indices were measured. Among 105 nodules, 14 were PTC and 91 were benign. The EMean, EMin, and EMax values were significantly higher in PTCs than benign nodules (EMean 37.4 in PTC vs. 23.7 in benign nodules, p = 0.005; EMin 27.9 vs. 17.8, p = 0.034; EMax 46.7 vs. 31.5, p < 0.001). The EMean, EMin, and EMax were significantly associated with PTC with diagnostic odds ratios varying from 6.74 to 9.91, high specificities (86.4%, 86.4%, and 88.1%, respectively), and positive likelihood ratios (4.21, 3.69, and 4.82, respectively). The ESD values were significantly higher in PTC than in benign nodules (6.3 vs. 2.6, p < 0.001). ESD had the highest specificity (96.6%) when applied with a cut-off value of 6.5 kPa. It had a positive likelihood ratio of 14.75 and a diagnostic odds ratio of 28.50. The shear elasticity index of ESD, with higher likelihood ratios for PTC, will probably identify nodules that have a high potential for malignancy. It may help to identify and select malignant nodules, while reducing unnecessary fine needle aspiration and core needle biopsies of benign nodules.

  20. Automated scoring system of standard uptake value for torso FDG-PET images

    NASA Astrophysics Data System (ADS)

    Hara, Takeshi; Kobayashi, Tatsunori; Kawai, Kazunao; Zhou, Xiangrong; Itoh, Satoshi; Katafuchi, Tetsuro; Fujita, Hiroshi

    2008-03-01

    The purpose of this work was to develop an automated method to calculate the score of SUV for torso region on FDG-PET scans. The three dimensional distributions for the mean and the standard deviation values of SUV were stored in each volume to score the SUV in corresponding pixel position within unknown scans. The modeling methods is based on SPM approach using correction technique of Euler characteristic and Resel (Resolution element). We employed 197 nor-mal cases (male: 143, female: 54) to assemble the normal metabolism distribution of FDG. The physique were registered each other in a rectangular parallelepiped shape using affine transformation and Thin-Plate-Spline technique. The regions of the three organs were determined based on semi-automated procedure. Seventy-three abnormal spots were used to estimate the effectiveness of the scoring methods. As a result, the score images correctly represented that the scores for normal cases were between zeros to plus/minus 2 SD. Most of the scores of abnormal spots associated with cancer were lager than the upper of the SUV interval of normal organs.

  1. HU deviation in lung and bone tissues: Characterization and a corrective strategy.

    PubMed

    Ai, Hua A; Meier, Joseph G; Wendt, Richard E

    2018-05-01

    In the era of precision medicine, quantitative applications of x-ray Computed Tomography (CT) are on the rise. These require accurate measurement of the CT number, also known as the Hounsfield Unit. In this study, we evaluated the effect of patient attenuation-induced beam hardening of the x-ray spectrum on the accuracy of the HU values and a strategy to correct for the resulting deviations in the measured HU values. A CIRS electron density phantom was scanned on a Siemens Biograph mCT Flow CT scanner and a GE Discovery 710 CT scanner using standard techniques that are employed in the clinic to assess the HU deviation caused by beam hardening in different tissue types. In addition, an anthropomorphic ATOM adult male upper torso phantom was scanned on the GE Discovery 710 scanner. Various amounts of Superflab bolus material were wrapped around the phantoms to simulate different patient sizes. The mean HU values that were measured in the phantoms were evaluated as a function of the water-equivalent area (A w ), a parameter that is described in the report of AAPM Task Group 220. A strategy by which to correct the HU values was developed and tested. The variation in the HU values in the anthropomorphic ATOM phantom under different simulated body sizes, both before and after correction, were compared, with a focus on the lung and bone tissues. Significant HU deviations that depended on the simulated patient size were observed. A positive correlation between HU and A w was observed for tissue types that have an HU of less than zero, while a negative correlation was observed for tissue types with HU values that are greater than zero. The magnitude of the difference increases as the underlying attenuation property deviates further away from that of water. In the electron density phantom study, the maximum observed HU differences between the measured and reference values in the cortical bone and lung materials were 426 and 94 HU, respectively. In the anthropomorphic phantom

  2. Fast and robust standard-deviation-based method for bulk motion compensation in phase-based functional OCT.

    PubMed

    Wei, Xiang; Camino, Acner; Pi, Shaohua; Cepurna, William; Huang, David; Morrison, John C; Jia, Yali

    2018-05-01

    Phase-based optical coherence tomography (OCT), such as OCT angiography (OCTA) and Doppler OCT, is sensitive to the confounding phase shift introduced by subject bulk motion. Traditional bulk motion compensation methods are limited by their accuracy and computing cost-effectiveness. In this Letter, to the best of our knowledge, we present a novel bulk motion compensation method for phase-based functional OCT. Bulk motion associated phase shift can be directly derived by solving its equation using a standard deviation of phase-based OCTA and Doppler OCT flow signals. This method was evaluated on rodent retinal images acquired by a prototype visible light OCT and human retinal images acquired by a commercial system. The image quality and computational speed were significantly improved, compared to two conventional phase compensation methods.

  3. Excursions out-of-lane versus standard deviation of lateral position as outcome measure of the on-the-road driving test.

    PubMed

    Verster, Joris C; Roth, Thomas

    2014-07-01

    The traditional outcome measure of the Dutch on-the-road driving test is the standard deviation of lateral position (SDLP), the weaving of the car. This paper explores whether excursions out-of-lane are a suitable additional outcome measure to index driving impairment. A literature search was conducted to search for driving tests that used both SDLP and excursions out-of-lane as outcome measures. The analyses were limited to studies examining hypnotic drugs because several of these drugs have been shown to produce next-morning sedation. Standard deviation of lateral position was more sensitive in demonstrating driving impairment. In fact, solely relying on excursions out-of-lane as outcome measure incorrectly classifies approximately half of impaired drives as unimpaired. The frequency of excursions out-of-lane is determined by the mean lateral position within the right traffic lane. Defining driving impairment as having a ΔSDLP > 2.4 cm, half of the impaired driving tests (51.2%, 43/84) failed to produce excursions out-of-lane. Alternatively, 20.9% of driving tests with ΔSDLP < 2.4 cm (27/129) had at least one excursion out-of-lane. Excursions out-of-lane are neither a suitable measure to demonstrate driving impairment nor is this measure sufficiently sensitive to differentiate adequately between differences in magnitude of driving impairment. Copyright © 2014 John Wiley & Sons, Ltd.

  4. A deviation display method for visualising data in mobile gamma-ray spectrometry.

    PubMed

    Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer

    2010-09-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  5. Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database.

    PubMed

    Nakajima, Kenichi; Matsumoto, Naoya; Kasai, Tokuo; Matsuo, Shinro; Kiso, Keisuke; Okuda, Koichi

    2016-04-01

    As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of (123)I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.

  6. Global, Hemispheric, and Zonal Temperature Deviations Derived From a 63-Station Radiosonde Network

    DOE Data Explorer

    Angell, J. K. [NOAA, Air Resources Laboratory

    2011-01-01

    Surface temperatures and thickness-derived temperatures from a 63-station, globally distributed radiosonde network have been used to estimate global, hemispheric, and zonal annual and seasonal temperature deviations. Most of the temperature values used were column-mean temperatures, obtained from the differences in height (thickness) between constant-pressure surfaces at individual radiosonde stations. The pressure-height data before 1980 were obtained from published values in Monthly Climatic Data for the World. Between 1980 and 1990, Angell used data from both the Climatic Data for the World and the Global Telecommunications System (GTS) Network received at the National Meteorological Center. Between 1990 and 1995, the data were obtained only from GTS, and since 1995 the data have been obtained from National Center for Atmospheric Research files. The data are evaluated as deviations from the mean based on the interval 1958-1977. The station deviations have been averaged (with equal weighting) to obtain annual and seasonal temperature deviations for the globe, the Northern and Southern Hemispheres, and the following latitudinal zones: North (60° N-90° N) and South (60° S-90° S) Polar; North (30° N-60° N) and South (30° S-60° S) Temperate; North (10° N-30° N) and South (10° S-30° S) Subtropical; Tropical(30° S-30° N); and Equatorial (10° S-10° N). The seasonal calculations are for the standard meteorological seasons (i.e., winter is defined as December, January, and February; spring is March, April, and May, etc.) and the annual calculations are for December through the following November (i.e., for the four meteorological seasons). For greater details, see Angell and Korshover (1983) and Angell (1988, 1991)

  7. Value-Based Standards Guide Sexism Inferences for Self and Others.

    PubMed

    Mitamura, Chelsea; Erickson, Lynnsey; Devine, Patricia G

    2017-09-01

    People often disagree about what constitutes sexism, and these disagreements can be both socially and legally consequential. It is unclear, however, why or how people come to different conclusions about whether something or someone is sexist. Previous research on judgments about sexism has focused on the perceiver's gender and attitudes, but neither of these variables identifies comparative standards that people use to determine whether any given behavior (or person) is sexist. Extending Devine and colleagues' values framework (Devine, Monteith, Zuwerink, & Elliot, 1991; Plant & Devine, 1998), we argue that, when evaluating others' behavior, perceivers rely on the morally-prescriptive values that guide their own behavior toward women. In a series of 3 studies we demonstrate that (1) people's personal standards for sexism in their own and others' behavior are each related to their values regarding sexism, (2) these values predict how much behavioral evidence people need to infer sexism, and (3) people with stringent, but not lenient, value-based standards get angry and try to regulate a sexist perpetrator's behavior to reduce sexism. Furthermore, these personal values are related to all outcomes in the present work above and beyond other person characteristics previously used to predict sexism inferences. We discuss the implications of differing value-based standards for explaining and reconciling disputes over what constitutes sexist behavior.

  8. Diagnostic value of ST-segment deviations during cardiac exercise stress testing: Systematic comparison of different ECG leads and time-points.

    PubMed

    Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias

    2017-07-01

    Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. The retest distribution of the visual field summary index mean deviation is close to normal.

    PubMed

    Anderson, Andrew J; Cheng, Allan C Y; Lau, Samantha; Le-Pham, Anne; Liu, Victor; Rahman, Farahnaz

    2016-09-01

    When modelling optimum strategies for how best to determine visual field progression in glaucoma, it is commonly assumed that the summary index mean deviation (MD) is normally distributed on repeated testing. Here we tested whether this assumption is correct. We obtained 42 reliable 24-2 Humphrey Field Analyzer SITA standard visual fields from one eye of each of five healthy young observers, with the first two fields excluded from analysis. Previous work has shown that although MD variability is higher in glaucoma, the shape of the MD distribution is similar to that found in normal visual fields. A Shapiro-Wilks test determined any deviation from normality. Kurtosis values for the distributions were also calculated. Data from each observer passed the Shapiro-Wilks normality test. Bootstrapped 95% confidence intervals for kurtosis encompassed the value for a normal distribution in four of five observers. When examined with quantile-quantile plots, distributions were close to normal and showed no consistent deviations across observers. The retest distribution of MD is not significantly different from normal in healthy observers, and so is likely also normally distributed - or nearly so - in those with glaucoma. Our results increase our confidence in the results of influential modelling studies where a normal distribution for MD was assumed. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  10. Improving IQ measurement in intellectual disabilities using true deviation from population norms.

    PubMed

    Sansone, Stephanie M; Schneider, Andrea; Bickel, Erika; Berry-Kravis, Elizabeth; Prescott, Christina; Hessl, David

    2014-01-01

    Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment.

  11. Improving IQ measurement in intellectual disabilities using true deviation from population norms

    PubMed Central

    2014-01-01

    Background Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. Methods We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. Results We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Conclusion Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment. PMID:26491488

  12. Evaluating deviations in prostatectomy patients treated with IMRT.

    PubMed

    Sá, Ana Cravo; Peres, Ana; Pereira, Mónica; Coelho, Carina Marques; Monsanto, Fátima; Macedo, Ana; Lamas, Adrian

    2016-01-01

    To evaluate the deviations in prostatectomy patients treated with IMRT in order to calculate appropriate margins to create the PTV. Defining inappropriate margins can lead to underdosing in target volumes and also overdosing in healthy tissues, increasing morbidity. 223 CBCT images used for alignment with the CT planning scan based on bony anatomy were analyzed in 12 patients treated with IMRT following prostatectomy. Shifts of CBCT images were recorded in three directions to calculate the required margin to create PTV. The mean and standard deviation (SD) values in millimetres were -0.05 ± 1.35 in the LR direction, -0.03 ± 0.65 in the SI direction and -0.02 ± 2.05 the AP direction. The systematic error measured in the LR, SI and AP direction were 1.35 mm, 0.65 mm, and 2.05 mm with a random error of 2.07 mm; 1.45 mm and 3.16 mm, resulting in a PTV margin of 4.82 mm; 2.64 mm, and 7.33 mm, respectively. With IGRT we suggest a margin of 5 mm, 3 mm and 8 mm in the LR, SI and AP direction, respectively, to PTV1 and PTV2. Therefore, this study supports an anisotropic margin expansion to the PTV being the largest expansion in the AP direction and lower in SI.

  13. CODATA recommended values of the fundamental constants

    NASA Astrophysics Data System (ADS)

    Mohr, Peter J.; Taylor, Barry N.

    2000-11-01

    A review is given of the latest Committee on Data for Science and Technology (CODATA) adjustment of the values of the fundamental constants. The new set of constants, referred to as the 1998 values, replaces the values recommended for international use by CODATA in 1986. The values of the constants, and particularly the Rydberg constant, are of relevance to the calculation of precise atomic spectra. The standard uncertainty (estimated standard deviation) of the new recommended value of the Rydberg constant, which is based on precision frequency metrology and a detailed analysis of the theory, is approximately 1/160 times the uncertainty of the 1986 value. The new set of recommended values as well as a searchable bibliographic database that gives citations to the relevant literature is available on the World Wide Web at physics.nist.gov/constants and physics.nist.gov/constantsbib, respectively. .

  14. Protocol deviations before and after IV tPA in community hospitals

    PubMed Central

    Adelman, Eric E.; Scott, Phillip A.; Skolarus, Lesli E.; Fox, Allison K.; Frederiksen, Shirley M.; Meurer, William J.

    2015-01-01

    Background Protocol deviations before and after tPA treatment for ischemic stroke are common. It is unclear if patient or hospital factors predict protocol deviations. We examined predictors of protocol deviations and the effects of protocol violations on symptomatic intracerebral hemorrhage. Methods We used data from the INSTINCT trial, a cluster-randomized, controlled trial evaluating the efficacy of a barrier assessment and educational intervention to increase appropriate tPA use in 24 Michigan community hospitals, to review tPA treatments between 2007 and 2010. Protocol violations were defined as deviations from the standard tPA protocol, both before and after treatment. Multi-level logistic regression models were fitted to determine if patient and hospital variables were associated with pre-treatment or post-treatment protocol deviations. Results During the study, 557 patients (mean age 70; 52% male; median NIHSS 12) were treated with tPA. Protocol deviations occurred in 233 (42%) patients: 16% had pre-treatment deviations, 35% had post-treatment deviations, and 9% had both. The most common protocol deviations included elevated post-treatment blood pressure, antithrombotic agent use within 24 hours of treatment, and elevated pre-treatment blood pressure. Protocol deviations were not associated with symptomatic intracerebral hemorrhage, stroke severity, or hospital factors. Older age was associated with pre-treatment protocol deviations (adjusted OR 0.52; 95% confidence interval 0.30-0.92). Pre-treatment deviations were associated with post-treatment deviations (adjusted OR 3.20; 95% confidence interval 1.91-5.35). Conclusions Protocol deviations were not associated with symptomatic intracerebral hemorrhage. Aside from age, patient and hospital factors were not associated with protocol deviations. PMID:26419527

  15. Evaluation of the 235 U resonance parameters to fit the standard recommended values

    DOE PAGES

    Leal, Luiz; Noguere, Gilles; Paradela, Carlos; ...

    2017-09-13

    A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235U interactionmore » in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.« less

  16. Evaluation of the 235 U resonance parameters to fit the standard recommended values

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leal, Luiz; Noguere, Gilles; Paradela, Carlos

    A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. We performed a resonance re-evaluation of the n + 235U interactionmore » in order to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-o-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. Our paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.« less

  17. Evaluation of the 235U resonance parameters to fit the standard recommended values

    NASA Astrophysics Data System (ADS)

    Leal, Luiz; Noguere, Gilles; Paradela, Carlos; Durán, Ignacio; Tassan-Got, Laurent; Danon, Yaron; Jandel, Marian

    2017-09-01

    A great deal of effort has been dedicated to the revision of the standard values in connection with the neutron interaction for some actinides. While standard data compilation are available for decades nuclear data evaluations included in existing nuclear data libraries (ENDF, JEFF, JENDL, etc.) do not follow the standard recommended values. Indeed, the majority of evaluations for major actinides do not conform to the standards whatsoever. In particular, for the n + 235U interaction the only value in agreement with the standard is the thermal fission cross section. A resonance re-evaluation of the n + 235U interaction has been performed to address the issues regarding standard values in the energy range from 10-5 eV to 2250 eV. Recently, 235U fission cross-section measurements have been performed at the CERN Neutron Time-of-Flight facility (TOF), known as n_TOF, in the energy range from 0.7 eV to 10 keV. The data were normalized according to the recommended standard of the fission integral in the energy range 7.8 eV to 11 eV. As a result, the n_TOF averaged fission cross sections above 100 eV are in good agreement with the standard recommended values. The n_TOF data were included in the 235U resonance analysis that was performed with the code SAMMY. In addition to the average standard values related to the fission cross section, standard thermal values for fission, capture, and elastic cross sections were also included in the evaluation. This paper presents the procedure used for re-evaluating the 235U resonance parameters including the recommended standard values as well as new cross section measurements.

  18. Human Rights and Values Education: Using the International Standards.

    ERIC Educational Resources Information Center

    Reardon, Betty A.

    1994-01-01

    Asserts that, in teaching about human rights, the international standards should be the fundamental core of the content and values to be communicated. Recommends that teachers should use the Universal Declaration of Human Rights as the standard by which the actions of individuals and governments should be compared. (CFR)

  19. Bodily Deviations and Body Image in Adolescence

    ERIC Educational Resources Information Center

    Vilhjalmsson, Runar; Kristjansdottir, Gudrun; Ward, Dianne S.

    2012-01-01

    Adolescents with unusually sized or shaped bodies may experience ridicule, rejection, or exclusion based on their negatively valued bodily characteristics. Such experiences can have negative consequences for a person's image and evaluation of self. This study focuses on the relationship between bodily deviations and body image and is based on a…

  20. Dataset on the mean, standard deviation, broad-sense heritability and stability of wheat quality bred in three different ways and grown under organic and low-input conventional systems.

    PubMed

    Rakszegi, Marianna; Löschenberger, Franziska; Hiltbrunner, Jürg; Vida, Gyula; Mikó, Péter

    2016-06-01

    An assessment was previously made of the effects of organic and low-input field management systems on the physical, grain compositional and processing quality of wheat and on the performance of varieties developed using different breeding methods ("Comparison of quality parameters of wheat varieties with different breeding origin under organic and low-input conventional conditions" [1]). Here, accompanying data are provided on the performance and stability analysis of the genotypes using the coefficient of variation and the 'ranking' and 'which-won-where' plots of GGE biplot analysis for the most important quality traits. Broad-sense heritability was also evaluated and is given for the most important physical and quality properties of the seed in organic and low-input management systems, while mean values and standard deviation of the studied properties are presented separately for organic and low-input fields.

  1. Effect of nasal deviation on quality of life.

    PubMed

    de Lima Ramos, Sueli; Hochman, Bernardo; Gomes, Heitor Carvalho; Abla, Luiz Eduardo Felipe; Veiga, Daniela Francescato; Juliano, Yara; Dini, Gal Moreira; Ferreira, Lydia Masako

    2011-07-01

    Nasal deviation is a common complaint in otorhinolaryngology and plastic surgery. This condition not only causes impairment of nasal function but also affects quality of life, leading to psychological distress. The subjective assessment of quality of life, as an important aspect of outcomes research, has received increasing attention in recent decades. Quality of life is measured using standardized questionnaires that have been tested for reliability, validity, and sensitivity. The aim of this study was to evaluate health-related quality of life, self-esteem, and depression in patients with nasal deviation. Sixty patients were selected for the study. Patients with nasal deviation (n = 32) were assigned to the study group, and patients without nasal deviation (n = 28) were assigned to the control group. The diagnosis of nasal deviation was made by digital photogrammetry. Quality of life was assessed using the Medical Outcomes Study 36-Item Short Form Health Survey questionnaire; the Rosenberg Self-Esteem/Federal University of São Paulo, Escola Paulista de Medicina Scale; and the 20-item Self-Report Questionnaire. There were significant differences between groups in the physical functioning and general health subscales of the Medical Outcomes Study 36-Item Short Form Health Survey (p < 0.05). Depression was detected in 11 patients (34.4 percent) in the study group and in two patients in the control group, with a significant difference between groups (p < 0.05). Nasal deviation is an aspect of rhinoplasty of which the surgeon should be aware so that proper psychological diagnosis can be made and suitable treatment can be planned because psychologically the patients with nasal deviation have significantly worse quality of life and are more prone to depression. Risk, II.(Figure is included in full-text article.).

  2. Determinants of ocular deviation in esotropic subjects under general anesthesia.

    PubMed

    Daien, Vincent; Turpin, Chloé; Lignereux, François; Belghobsi, Riadh; Le Meur, Guylene; Lebranchu, Pierre; Pechereau, Alain

    2013-01-01

    The authors attempted to identify the determinants of ocular deviation in a population of patients with esotropia under general anesthesia. Forty-one patients with esotropia were included. Horizontal ocular deviation was evaluated by the photographic Hirschberg test both in the awakened state and under general anesthesia before surgery. Changes in ocular deviation were measured and a multivariate analysis was used to assess its clinical determinants. The mean age (± standard deviation [SD]) of study subjects was 13 ± 11 years and 51% were females. The mean spherical equivalent refraction of the right eye was 2.44 ± 2.50 diopters (D), with no significant difference between eyes (P = .26). The mean ocular deviation changed significantly, from 33.5 ± 12.5 prism diopters (PD) at preoperative examination to 8.8 ± 11.4 PD under general anesthesia (P = .0001). The changes in ocular deviation positively correlated with the pre-operative ocular deviation (correlation coefficient r = 0.59, P = .0001) and negatively correlated with patient age (correlation coefficient r = -0.53, P = .0001). These two determinants remained significant after multivariate adjustment of the following variables: preoperative ocular deviation; age; gender; spherical equivalent refraction; and number of previous strabismus surgeries (model r(2) = 0.49, P = .0001). The ocular position under general anesthesia was reported as a key factor in the surgical treatment of subjects with esotropia; therefore, its clinical determinants were assessed. The authors observed that preoperative ocular deviation and patient age were the main factors that influenced the ocular position under general anesthesia. Copyright 2013, SLACK Incorporated.

  3. Deviation from intention to treat analysis in randomised trials and treatment effect estimates: meta-epidemiological study.

    PubMed

    Abraha, Iosief; Cherubini, Antonio; Cozzolino, Francesco; De Florio, Rita; Luchetta, Maria Laura; Rimland, Joseph M; Folletti, Ilenia; Marchesi, Mauro; Germani, Antonella; Orso, Massimiliano; Eusebi, Paolo; Montedori, Alessandro

    2015-05-27

    To examine whether deviation from the standard intention to treat analysis has an influence on treatment effect estimates of randomised trials. Meta-epidemiological study. Medline, via PubMed, searched between 2006 and 2010; 43 systematic reviews of interventions and 310 randomised trials were included. From each year searched, random selection of 5% of intervention reviews with a meta-analysis that included at least one trial that deviated from the standard intention to treat approach. Basic characteristics of the systematic reviews and randomised trials were extracted. Information on the reporting of intention to treat analysis, outcome data, risk of bias items, post-randomisation exclusions, and funding were extracted from each trial. Trials were classified as: ITT (reporting the standard intention to treat approach), mITT (reporting a deviation from the standard approach), and no ITT (reporting no approach). Within each meta-analysis, treatment effects were compared between mITT and ITT trials, and between mITT and no ITT trials. The ratio of odds ratios was calculated (value <1 indicated larger treatment effects in mITT trials than in other trial categories). 50 meta-analyses and 322 comparisons of randomised trials (from 84 ITT trials, 118 mITT trials, and 108 no ITT trials; 12 trials contributed twice to the analysis) were examined. Compared with ITT trials, mITT trials showed a larger intervention effect (pooled ratio of odds ratios 0.83 (95% confidence interval 0.71 to 0.96), P=0.01; between meta-analyses variance τ(2)=0.13). Adjustments for sample size, type of centre, funding, items of risk of bias, post-randomisation exclusions, and variance of log odds ratio yielded consistent results (0.80 (0.69 to 0.94), P=0.005; τ(2)=0.08). After exclusion of five influential studies, results remained consistent (0.85 (0.75 to 0.98); τ(2)=0.08). The comparison between mITT trials and no ITT trials showed no statistical difference between the two groups (adjusted

  4. Note Onset Deviations as Musical Piece Signatures

    PubMed Central

    Serrà, Joan; Özaslan, Tan Hakan; Arcos, Josep Lluis

    2013-01-01

    A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields. PMID:23935971

  5. Note onset deviations as musical piece signatures.

    PubMed

    Serrà, Joan; Özaslan, Tan Hakan; Arcos, Josep Lluis

    2013-01-01

    A competent interpretation of a musical composition presents several non-explicit departures from the written score. Timing variations are perhaps the most important ones: they are fundamental for expressive performance and a key ingredient for conferring a human-like quality to machine-based music renditions. However, the nature of such variations is still an open research question, with diverse theories that indicate a multi-dimensional phenomenon. In the present study, we consider event-shift timing variations and show that sequences of note onset deviations are robust and reliable predictors of the musical piece being played, irrespective of the performer. In fact, our results suggest that only a few consecutive onset deviations are already enough to identify a musical composition with statistically significant accuracy. We consider a mid-size collection of commercial recordings of classical guitar pieces and follow a quantitative approach based on the combination of standard statistical tools and machine learning techniques with the semi-automatic estimation of onset deviations. Besides the reported results, we believe that the considered materials and the methodology followed widen the testing ground for studying musical timing and could open new perspectives in related research fields.

  6. Standard value of ultrasound elastography using acoustic radiation force impulse imaging (ARFI) in healthy liver tissue of children and adolescents.

    PubMed

    Eiler, J; Kleinholdermann, U; Albers, D; Dahms, J; Hermann, F; Behrens, C; Luedemann, M; Klingmueller, V; Alzen, G F P

    2012-10-01

    Ultrasound elastography by acoustic radiation force impulse imaging (ARFI) is used in adults for non invasive measurement of liver stiffness, indicating liver diseases like fibrosis. To establish ARFI in children and adolescents we determined standard values of healthy liver tissue and analysed potentially influencing factors. 132 patients between 0 and 17 years old were measured using ARFI. None of them had any liver disease or any other disease that could affect the liver secondarily. All patients had a normal ultrasound scan, a normal BMI and normal liver function tests. The mean value of all ARFI measurements was calculated and potentially influencing factors were analysed. The mean value of all ARFI elastography measurements was 1.16 m/sec (SD ± 0.14 m/sec). Neither age (p = 0.533) nor depth of measurement (p = 0.066) had no significant influence on ARFI values, whereas a significant effect of gender was found with lower ARFI values in females (p = 0.025), however, there was no significant interaction between age groups (before or after puberty) and gender (p = 0.276). There was an interlobar difference with lower values in the right liver lobe compared to the left (p = 0.036) and with a significantly lower variance (p < 0.001). Consistend values were measured by different examiners (p = 0.108), however, the inter examiner variance deviated significantly (p < 0.001). ARFI elastography is a reliable method to measure liver stiffness in children and adolescents. In relation to studies which analyse liver diseases, the standard value of 1.16 m/sec (± 0.14 m/sec) allows a differentiation of healthy versus pathological liver tissue. © Georg Thieme Verlag KG Stuttgart · New York.

  7. A Generalized Polynomial Chaos-Based Approach to Analyze the Impacts of Process Deviations on MEMS Beams.

    PubMed

    Gao, Lili; Zhou, Zai-Fa; Huang, Qing-An

    2017-11-08

    A microstructure beam is one of the fundamental elements in MEMS devices like cantilever sensors, RF/optical switches, varactors, resonators, etc. It is still difficult to precisely predict the performance of MEMS beams with the current available simulators due to the inevitable process deviations. Feasible numerical methods are required and can be used to improve the yield and profits of the MEMS devices. In this work, process deviations are considered to be stochastic variables, and a newly-developed numerical method, i.e., generalized polynomial chaos (GPC), is applied for the simulation of the MEMS beam. The doubly-clamped polybeam has been utilized to verify the accuracy of GPC, compared with our Monte Carlo (MC) approaches. Performance predictions have been made on the residual stress by achieving its distributions in GaAs Monolithic Microwave Integrated Circuit (MMIC)-based MEMS beams. The results show that errors are within 1% for the results of GPC approximations compared with the MC simulations. Appropriate choices of the 4-order GPC expansions with orthogonal terms have also succeeded in reducing the MC simulation labor. The mean value of the residual stress, concluded from experimental tests, shares an error about 1.1% with that of the 4-order GPC method. It takes a probability around 54.3% for the 4-order GPC approximation to attain the mean test value of the residual stress. The corresponding yield occupies over 90 percent around the mean within the twofold standard deviations.

  8. A Generalized Polynomial Chaos-Based Approach to Analyze the Impacts of Process Deviations on MEMS Beams

    PubMed Central

    Gao, Lili

    2017-01-01

    A microstructure beam is one of the fundamental elements in MEMS devices like cantilever sensors, RF/optical switches, varactors, resonators, etc. It is still difficult to precisely predict the performance of MEMS beams with the current available simulators due to the inevitable process deviations. Feasible numerical methods are required and can be used to improve the yield and profits of the MEMS devices. In this work, process deviations are considered to be stochastic variables, and a newly-developed numerical method, i.e., generalized polynomial chaos (GPC), is applied for the simulation of the MEMS beam. The doubly-clamped polybeam has been utilized to verify the accuracy of GPC, compared with our Monte Carlo (MC) approaches. Performance predictions have been made on the residual stress by achieving its distributions in GaAs Monolithic Microwave Integrated Circuit (MMIC)-based MEMS beams. The results show that errors are within 1% for the results of GPC approximations compared with the MC simulations. Appropriate choices of the 4-order GPC expansions with orthogonal terms have also succeeded in reducing the MC simulation labor. The mean value of the residual stress, concluded from experimental tests, shares an error about 1.1% with that of the 4-order GPC method. It takes a probability around 54.3% for the 4-order GPC approximation to attain the mean test value of the residual stress. The corresponding yield occupies over 90 percent around the mean within the twofold standard deviations. PMID:29117096

  9. Longitudinal meta-analysis of NIST pH Standard Reference Materials(®): a complement to pH key comparisons.

    PubMed

    Pratt, Kenneth W

    2015-04-01

    This meta-analysis assesses the long-term (up to 70 years) within-laboratory variation of the NIST pH Standard Reference Material® (SRM) tetroxalate, phthalate, phosphate, borate, and carbonate buffers. Values of ΔpH(S), the difference between the certified pH value, pH(S), of each SRM issue and the mean of all pH(S) values for the given SRM at that Celsius temperature, t, are graphed as a function of the SRM issue and t. In most cases, |ΔpH(S)| < 0.004. Deviations from the nominal base:acid amount (mole) ratio of a buffer yield t-independent, constant shifts in ΔpH(S). The mean ΔpH(S) characterizes such deviations. The corresponding mole fraction of impurity in the conjugate buffer component is generally <0.3 %. Changes in the equipment, personnel, materials, and methodology of the pH(S) measurement yield t-dependent variations. The standard deviation of ΔpH(S) characterizes such changes. Standard deviations of ΔpH(S) are generally 0.0015 or less. The results provide a long-term, single-institution complement to the time-specific, multi-institution results of pH key comparisons administered by the Consultative Committee for Metrology in Chemistry and Biology (CCQM).

  10. Efficiency and large deviations in time-asymmetric stochastic heat engines

    DOE PAGES

    Gingrich, Todd R.; Rotskoff, Grant M.; Vaikuntanathan, Suriyanarayanan; ...

    2014-10-24

    In a stochastic heat engine driven by a cyclic non-equilibrium protocol, fluctuations in work and heat give rise to a fluctuating efficiency. Using computer simulations and tools from large deviation theory, we have examined these fluctuations in detail for a model two-state engine. We find in general that the form of efficiency probability distributions is similar to those described by Verley et al (2014 Nat. Commun. 5 4721), in particular featuring a local minimum in the long-time limit. In contrast to the time-symmetric engine protocols studied previously, however, this minimum need not occur at the value characteristic of a reversible Carnot engine. Furthermore, while the local minimum may reside at the global minimum of a large deviation rate function, it does not generally correspond to the least likely efficiency measured over finite time. Lastly, we introduce a general approximation for the finite-time efficiency distribution,more » $$P(\\eta )$$, based on large deviation statistics of work and heat, that remains very accurate even when $$P(\\eta )$$ deviates significantly from its large deviation form.« less

  11. A simulation study of nonparametric total deviation index as a measure of agreement based on quantile regression.

    PubMed

    Lin, Lawrence; Pan, Yi; Hedayat, A S; Barnhart, Huiman X; Haber, Michael

    2016-01-01

    Total deviation index (TDI) captures a prespecified quantile of the absolute deviation of paired observations from raters, observers, methods, assays, instruments, etc. We compare the performance of TDI using nonparametric quantile regression to the TDI assuming normality (Lin, 2000). This simulation study considers three distributions: normal, Poisson, and uniform at quantile levels of 0.8 and 0.9 for cases with and without contamination. Study endpoints include the bias of TDI estimates (compared with their respective theoretical values), standard error of TDI estimates (compared with their true simulated standard errors), and test size (compared with 0.05), and power. Nonparametric TDI using quantile regression, although it slightly underestimates and delivers slightly less power for data without contamination, works satisfactorily under all simulated cases even for moderate (say, ≥40) sample sizes. The performance of the TDI based on a quantile of 0.8 is in general superior to that of 0.9. The performances of nonparametric and parametric TDI methods are compared with a real data example. Nonparametric TDI can be very useful when the underlying distribution on the difference is not normal, especially when it has a heavy tail.

  12. Properties of pattern standard deviation in open-angle glaucoma patients with hemi-optic neuropathy and bi-optic neuropathy.

    PubMed

    Heo, Dong Won; Kim, Kyoung Nam; Lee, Min Woo; Lee, Sung Bok; Kim, Chang-Sik

    2017-01-01

    To evaluate the properties of pattern standard deviation (PSD) according to localization of the glaucomatous optic neuropathy. We enrolled 242 eyes of 242 patients with primary open-angle glaucoma, with a best-corrected visual acuity ≥ 20/25, and no media opacity. Patients were examined via dilated fundus photography, spectral-domain optical coherence tomography, and Humphrey visual field examination, and divided into those with hemi-optic neuropathy (superior or inferior) and bi-optic neuropathy (both superior and inferior). We assessed the relationship between mean deviation (MD) and PSD. Using broken stick regression analysis, the tipping point was identified, i.e., the point at which MD became significantly associated with a paradoxical reversal of PSD. In 91 patients with hemi-optic neuropathy, PSD showed a strong correlation with MD (r = -0.973, β = -0.965, p < 0.001). The difference between MD and PSD ("-MD-PSD") was constant (mean, -0.32 dB; 95% confidence interval, -2.48~1.84 dB) regardless of visual field defect severity. However, in 151 patients with bi-optic neuropathy, a negative correlation was evident between "-MD-PSD" and MD (r2 = 0.907, p < 0.001). Overall, the MD tipping point was -14.0 dB, which was close to approximately 50% damage of the entire visual field (p < 0.001). Although a false decrease of PSD usually begins at approximately 50% visual field damage, in patients with hemi-optic neuropathy, the PSD shows no paradoxical decrease and shows a linear correlation with MD.

  13. Deviations from Newton's law in supersymmetric large extra dimensions

    NASA Astrophysics Data System (ADS)

    Callin, P.; Burgess, C. P.

    2006-09-01

    Deviations from Newton's inverse-squared law at the micron length scale are smoking-gun signals for models containing supersymmetric large extra dimensions (SLEDs), which have been proposed as approaches for resolving the cosmological constant problem. Just like their non-supersymmetric counterparts, SLED models predict gravity to deviate from the inverse-square law because of the advent of new dimensions at sub-millimeter scales. However SLED models differ from their non-supersymmetric counterparts in three important ways: (i) the size of the extra dimensions is fixed by the observed value of the dark energy density, making it impossible to shorten the range over which new deviations from Newton's law must be seen; (ii) supersymmetry predicts there to be more fields in the extra dimensions than just gravity, implying different types of couplings to matter and the possibility of repulsive as well as attractive interactions; and (iii) the same mechanism which is purported to keep the cosmological constant naturally small also keeps the extra-dimensional moduli effectively massless, leading to deviations from general relativity in the far infrared of the scalar-tensor form. We here explore the deviations from Newton's law which are predicted over micron distances, and show the ways in which they differ and resemble those in the non-supersymmetric case.

  14. Final height in survivors of childhood cancer compared with Height Standard Deviation Scores at diagnosis.

    PubMed

    Knijnenburg, S L; Raemaekers, S; van den Berg, H; van Dijk, I W E M; Lieverst, J A; van der Pal, H J; Jaspers, M W M; Caron, H N; Kremer, L C; van Santen, H M

    2013-04-01

    Our study aimed to evaluate final height in a cohort of Dutch childhood cancer survivors (CCS) and assess possible determinants of final height, including height at diagnosis. We calculated standard deviation scores (SDS) for height at initial cancer diagnosis and height in adulthood in a cohort of 573 CCS. Multivariable regression analyses were carried out to estimate the influence of different determinants on height SDS at follow-up. Overall, survivors had a normal height SDS at cancer diagnosis. However, at follow-up in adulthood, 8.9% had a height ≤-2 SDS. Height SDS at diagnosis was an important determinant for adult height SDS. Children treated with (higher doses of) radiotherapy showed significantly reduced final height SDS. Survivors treated with total body irradiation (TBI) and craniospinal radiation had the greatest loss in height (-1.56 and -1.37 SDS, respectively). Younger age at diagnosis contributed negatively to final height. Height at diagnosis was an important determinant for height SDS at follow-up. Survivors treated with TBI, cranial and craniospinal irradiation should be monitored periodically for adequate linear growth, to enable treatment on time if necessary. For correct interpretation of treatment-related late effects studies in CCS, pre-treatment data should always be included.

  15. SETs: stand evaluation tools: II. tree value conversion standards for hardwood sawtimber

    Treesearch

    Joseph J. Mendel; Paul S. DeBald; Martin E. Dale

    1976-01-01

    Tree quatity index tables are presented for 12 important hardwood species of the oak-hickory forest. From these, tree value conversion standards are developed for each species, log grade, merchantable height, and diameter at breast height. The method of calculating tree value conversion standards and adapting them to different conditions is explained. A computer...

  16. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

    PubMed

    Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W

    1995-01-01

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.

  17. Analysis of measurement deviations for the patient-specific quality assurance using intensity-modulated spot-scanning particle beams

    NASA Astrophysics Data System (ADS)

    Li, Yongqiang; Hsi, Wen C.

    2017-04-01

    To analyze measurement deviations of patient-specific quality assurance (QA) using intensity-modulated spot-scanning particle beams, a commercial radiation dosimeter using 24 pinpoint ionization chambers was utilized. Before the clinical trial, validations of the radiation dosimeter and treatment planning system were conducted. During the clinical trial 165 measurements were performed on 36 enrolled patients. Two or three fields of particle beam were used for each patient. Measurements were typically performed with the dosimeter placed at special regions of dose distribution along depth and lateral profiles. In order to investigate the dosimeter accuracy, repeated measurements with uniform dose irradiations were also carried out. A two-step approach was proposed to analyze 24 sampling points over a 3D treatment volume. The mean value and the standard deviation of each measurement did not exceed 5% for all measurements performed on patients with various diseases. According to the defined intervention thresholds of mean deviation and the distance-to-agreement concept with a Gamma index analysis using criteria of 3.0% and 2 mm, a decision could be made regarding whether the dose distribution was acceptable for the patient. Based measurement results, deviation analysis was carried out. In this study, the dosimeter was used for dose verification and provided a safety guard to assure precise dose delivery of highly modulated particle therapy. Patient-specific QA will be investigated in future clinical operations.

  18. 48 CFR 2001.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2001... Individual deviations. In individual cases, deviations from either the FAR or the NRCAR will be authorized... deviations clearly in the best interest of the Government. Individual deviations must be authorized in...

  19. 48 CFR 801.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations. 801... Individual deviations. (a) Authority to authorize individual deviations from the FAR and VAAR is delegated to... nature of the deviation. (d) The DSPE may authorize individual deviations from the FAR and VAAR when an...

  20. The Effect of Type of Punishment on Resistance to Deviation.

    ERIC Educational Resources Information Center

    LaVoie, Joseph C.

    The comparative effectiveness of an aversive stimulus, withholding of resources, withdrawal of love and reasoning, when used alone and combined with praise, was assessed in the standard laboratory punishment paradigm using 120 first and second graders as subjects. Resistance to deviation was used as the measure of punishment effectiveness. Sex of…

  1. How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation.

    PubMed

    Scholkmann, F; Spichtig, S; Muehlemann, T; Wolf, M

    2010-05-01

    Near-infrared imaging (NIRI) is a neuroimaging technique which enables us to non-invasively measure hemodynamic changes in the human brain. Since the technique is very sensitive, the movement of a subject can cause movement artifacts (MAs), which affect the signal quality and results to a high degree. No general method is yet available to reduce these MAs effectively. The aim was to develop a new MA reduction method. A method based on moving standard deviation and spline interpolation was developed. It enables the semi-automatic detection and reduction of MAs in the data. It was validated using simulated and real NIRI signals. The results show that a significant reduction of MAs and an increase in signal quality are achieved. The effectiveness and usability of the method is demonstrated by the improved detection of evoked hemodynamic responses. The present method can not only be used in the postprocessing of NIRI signals but also for other kinds of data containing artifacts, for example ECG or EEG signals.

  2. 2S-4S spectroscopy in hydrogen atom: The new value for the Rydberg constant and the proton charge radius

    NASA Astrophysics Data System (ADS)

    Kolachevsky, N.; Beyer, A.; Maisenbacher, L.; Matveev, A.; Pohl, R.; Khabarova, K.; Grinin, A.; Lamour, T.; Yost, D. C.; Haensch, T. W.; Udem, Th.

    2018-02-01

    The core of the "proton radius puzzle" is the discrepancy of four standard deviations between the proton root mean square charge radii (rp) determined from regular hydrogen (H), and the muonic hydrogen atom (μp). We have measured the 2S-4P transition frequency in H, utilizing a cryogenic beam of H and directly demonstrate that quantum interference of neighboring atomic resonances can lead to line shifts much larger than the proton radius discrepancy. Using an asymmetric fit function we obtain rp = 0.8335(95) fm and the Rydberg constant R∞ = 10 973 731.568 076 (96) m-1. The new value for rp is 3.3 combined standard deviations smaller than the latest CODATA value, but in good agreement with the value from μp.

  3. Implementation of an Algorithm for Prosthetic Joint Infection: Deviations and Problems.

    PubMed

    Mühlhofer, Heinrich M L; Kanz, Karl-Georg; Pohlig, Florian; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; von Eisenhart-Rothe, Ruediger; Schauwecker, Johannes

    The outcome of revision surgery in arthroplasty is based on a precise diagnosis. In addition, the treatment varies based on whether the prosthetic failure is caused by aseptic or septic loosening. Algorithms can help to identify periprosthetic joint infections (PJI) and standardize diagnostic steps, however, algorithms tend to oversimplify the treatment of complex cases. We conducted a process analysis during the implementation of a PJI algorithm to determine problems and deviations associated with the implementation of this algorithm. Fifty patients who were treated after implementing a standardized algorithm were monitored retrospectively. Their treatment plans and diagnostic cascades were analyzed for deviations from the implemented algorithm. Each diagnostic procedure was recorded, compared with the algorithm, and evaluated statistically. We detected 52 deviations while treating 50 patients. In 25 cases, no discrepancy was observed. Synovial fluid aspiration was not performed in 31.8% of patients (95% confidence interval [CI], 18.1%-45.6%), while white blood cell counts (WBCs) and neutrophil differentiation were assessed in 54.5% of patients (95% CI, 39.8%-69.3%). We also observed that the prolonged incubation of cultures was not requested in 13.6% of patients (95% CI, 3.5%-23.8%). In seven of 13 cases (63.6%; 95% CI, 35.2%-92.1%), arthroscopic biopsy was performed; 6 arthroscopies were performed in discordance with the algorithm (12%; 95% CI, 3%-21%). Self-critical analysis of diagnostic processes and monitoring of deviations using algorithms are important and could increase the quality of treatment by revealing recurring faults.

  4. On Deviations between Observed and Theoretically Estimated Values on Additivity-Law Failures

    NASA Astrophysics Data System (ADS)

    Nayatani, Yoshinobu; Sobagaki, Hiroaki

    The authors have reported in the previous studies that the average observed results are about a half of the corresponding predictions on the experiments with large additivity-law failures. One of the reasons of the deviations is studied and clarified by using the original observed data on additivity-law failures in the Nakano experiment. The conclusion from the observations and their analyses clarified that it was essentially difficult to have a good agreement between the average observed results and the corresponding theoretical predictions in the experiments with large additivity-law failures. This is caused by a kind of unavoidable psychological pressure existing in subjects participated in the experiments. We should be satisfied with the agreement in trend between them.

  5. Lower levels of insulin-like growth factor-1 standard deviation score are associated with histological severity of non-alcoholic fatty liver disease.

    PubMed

    Sumida, Yoshio; Yonei, Yoshikazu; Tanaka, Saiyu; Mori, Kojiroh; Kanemasa, Kazuyuki; Imai, Shunsuke; Taketani, Hiroyoshi; Hara, Tasuku; Seko, Yuya; Ishiba, Hiroshi; Okajima, Akira; Yamaguchi, Kanji; Moriguchi, Michihisa; Mitsuyoshi, Hironori; Yasui, Kohichiroh; Minami, Masahito; Itoh, Yoshito

    2015-07-01

    Growth hormone (GH) deficiency may be associated with histological progression of non-alcoholic fatty liver disease (NAFLD) which includes non-alcoholic fatty liver (NAFL) and non-alcoholic steatohepatitis (NASH). Insulin-like growth factor 1 (IGF-1) is mainly produced by hepatocytes and its secretion is stimulated by GH. Our aim was to determine whether more histologically advanced NAFLD is associated with low circulating levels of IGF-1 in Japanese patients. Serum samples were obtained in 199 Japanese patients with biopsy-proven NAFLD and in 2911 sex- and age-matched healthy people undergoing health checkups. The serum levels of IGF-1 were measured using a commercially available immunoradiometric assay. The standard deviation scores (SDS) of IGF-1 according to age and sex were also calculated in NAFLD patients. The serum IGF-1 levels in NAFLD patients were significantly lower (median, 112 ng/mL) compared with the control population (median, 121 ng/mL, P < 0.0001). IGF-1 SDS less than -2.0 SD from median were found in 11.6% of 199 patients. NASH patients exhibited significantly lower levels of IGF-1 SDS (n = 130; median, -0.7) compared with NAFL patients (n = 69; median, -0.3; P = 0.026). The IGF-1 SDS values decreased significantly with increasing lobular inflammation (P < 0.001) and fibrosis (P < 0.001). In multiple regressions, the association between the IGF-1 SDS values and the severity of NAFLD persisted after adjusting for age, sex and insulin resistance. Low levels of circulating IGF-1 may have a role in the development of advanced NAFLD, independent of insulin resistance. Supplementation with GH/IGF-1 may be a candidate for the treatment of NASH. © 2014 The Japan Society of Hepatology.

  6. 10 CFR 602.4 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Deviations. 602.4 Section 602.4 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.4 Deviations. (a) Single-case deviations from this part may be authorized in writing by the...

  7. 10 CFR 602.4 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Deviations. 602.4 Section 602.4 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.4 Deviations. (a) Single-case deviations from this part may be authorized in writing by the...

  8. 10 CFR 602.4 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Deviations. 602.4 Section 602.4 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.4 Deviations. (a) Single-case deviations from this part may be authorized in writing by the...

  9. 10 CFR 602.4 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Deviations. 602.4 Section 602.4 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.4 Deviations. (a) Single-case deviations from this part may be authorized in writing by the...

  10. 10 CFR 602.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Deviations. 602.4 Section 602.4 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.4 Deviations. (a) Single-case deviations from this part may be authorized in writing by the...

  11. 48 CFR 1501.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 1501.403 Section 1501.403 Federal Acquisition Regulations System ENVIRONMENTAL PROTECTION AGENCY GENERAL GENERAL Deviations 1501.403 Individual deviations. Requests for individual deviations from the FAR and the...

  12. [Fibrin glue for operative correction of septal deviations].

    PubMed

    Boenisch, M; Nolst Trenité, G J

    2004-11-01

    The routine procedure after correction of septal deviations is the utilization of endonasal packing in order to avoid septal haematoma. However, the mechanical pressure of this packing damages the mucociliar activity of the mucosa and causes lymphoedema by blocking the lymphatic vessels. Besides it represents a foreign body within the nose causing pain and unpleasant feeling for the patient. In order to avoid these disadvantages, in 57 patients we used fibrin glue instead of nasal packing. After correction of the septal deviation the two mucoperichondrium blades where fixed together with Tissucol Duo Quick. This technique not only leads to haemostasis, but also provides fixation of the newly modeled septum. In only one patient we found a small unilateral septal haematoma, in all other cases the postoperative period showed no complications. Patients had a significant reduction of endonasal crusts and postoperative swelling. Patients comfort increased significant without the (standard) nasal packing.

  13. 48 CFR 2401.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2401... DEVELOPMENT GENERAL FEDERAL ACQUISITION REGULATION SYSTEM Deviations 2401.403 Individual deviations. In individual cases, proposed deviations from the FAR or HUDAR shall be submitted to the Senior Procurement...

  14. 48 CFR 3401.404 - Class deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Class deviations. 3401.404 Section 3401.404 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Deviations 3401.404 Class deviations. A class deviation from the...

  15. Effects of central nervous system drugs on driving: speed variability versus standard deviation of lateral position as outcome measure of the on-the-road driving test.

    PubMed

    Verster, Joris C; Roth, Thomas

    2014-01-01

    The on-the-road driving test in normal traffic is used to examine the impact of drugs on driving performance. This paper compares the sensitivity of standard deviation of lateral position (SDLP) and SD speed in detecting driving impairment. A literature search was conducted to identify studies applying the on-the-road driving test, examining the effects of anxiolytics, antidepressants, antihistamines, and hypnotics. The proportion of comparisons (treatment versus placebo) where a significant impairment was detected with SDLP and SD speed was compared. About 40% of 53 relevant papers did not report data on SD speed and/or SDLP. After placebo administration, the correlation between SDLP and SD speed was significant but did not explain much variance (r = 0.253, p = 0.0001). A significant correlation was found between ΔSDLP and ΔSD speed (treatment-placebo), explaining 48% of variance. When using SDLP as outcome measure, 67 significant treatment-placebo comparisons were found. Only 17 (25.4%) were significant when SD speed was used as outcome measure. Alternatively, for five treatment-placebo comparisons, a significant difference was found for SD speed but not for SDLP. Standard deviation of lateral position is a more sensitive outcome measure to detect driving impairment than speed variability.

  16. Visual field progression in glaucoma: total versus pattern deviation analyses.

    PubMed

    Artes, Paul H; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-12-01

    visual fields' general height (estimated by the 85th percentile of the total deviation values) confirmed that change in the glaucomatous eyes almost always comprised a diffuse component. Pattern deviation analyses of progression may therefore underestimate the true amount of glaucomatous visual field progression. Pattern deviation analyses of visual field progression may underestimate visual field progression in glaucoma, particularly when there is no clinical evidence of increasing media opacity. Clinicians should have access to both total and pattern deviation analyses to make informed decisions on visual field progression in glaucoma.

  17. Myocardial infarct sizing by late gadolinium-enhanced MRI: Comparison of manual, full-width at half-maximum, and n-standard deviation methods.

    PubMed

    Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien

    2016-11-01

    To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.

  18. 48 CFR 1301.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations... DEPARTMENT OF COMMERCE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR 1301.403 Individual deviations. The designee authorized to approve individual deviations from the FAR is set forth in CAM 1301.70. ...

  19. 48 CFR 301.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 301... ACQUISITION REGULATION SYSTEM Deviations From the FAR 301.403 Individual deviations. Contracting activities shall prepare requests for individual deviations to either the FAR or HHSAR in accordance with 301.470. ...

  20. 48 CFR 1201.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations... FEDERAL ACQUISITION REGULATIONS SYSTEM 70-Deviations From the FAR and TAR 1201.403 Individual deviations... Executive Service (SES) official or that of a Flag Officer, may authorize individual deviations (unless (FAR...

  1. Morphologic changes of the anal sphincter musculature during and after temporary stool deviation.

    PubMed

    Sailer, M; Fein, M; Fuchs, K H; Bussen, D; Grun, C; Thiede, A

    2001-04-01

    Temporary stool deviation, using a stoma, is a well-known surgical principle to protect low colorectal or coloanal anastomoses. The purpose of this study was to evaluate any morphologic changes with regard to the anal sphincter muscles during and after temporary ileostomy. Forty-four patients with rectal carcinomas were studied prospectively. All patients underwent low anterior resection. Reconstruction was performed using either a coloanal pouch or a straight end-to-end anastomosis. A protective stoma was fashioned in all 44 patients (ileostomy n=41; colostomy n=3). Stoma closure was carried out after a median of 85 days (41-330 days). Using a standard protocol, anal-sphincter thickness [m. puborectalis, external anal sphincter (EAS) and internal anal (IAS) sphincter] was assessed by means of endoanal ultrasonography preoperatively, at the time of stoma closure, and every 3 months thereafter for 1 year. The diameter of the puborectal muscle decreased from a median preoperative value of 6.3 mm to 5.7 mm at the time of stoma closure (P=0.03). After 3 months, 6.2 mm was measured. This value remained stable for the complete follow-up period. Similar results were recorded for the EAS. The IAS thickness remained stable throughout the study period, measuring between 2.1 mm and 2.4 mm. Temporary stool deviation does lead to morphologic changes of the anal sphincter. While the smooth muscle remains unchanged, the striated counterpart undergoes atrophic transformation. However, after passage reconstruction, i.e., stoma closure, a rapid regeneration of the voluntary muscles is observed.

  2. 48 CFR 501.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 501... Individual deviations. (a) An individual deviation affects only one contract action. (1) The Head of the Contracting Activity (HCA) must approve an individual deviation to the FAR. The authority to grant an...

  3. 48 CFR 2801.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2801... OF JUSTICE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR and JAR 2801.403 Individual deviations. Individual deviations from the FAR or the JAR shall be approved by the head of the contracting...

  4. 48 CFR 401.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 401... AGRICULTURE ACQUISITION REGULATION SYSTEM Deviations From the FAR and AGAR 401.403 Individual deviations. In individual cases, deviations from either the FAR or the AGAR will be authorized only when essential to effect...

  5. NIST/ISAC standardization study: variability in assignment of intensity values to fluorescence standard beads and in cross calibration of standard beads to hard dyed beads.

    PubMed

    Hoffman, Robert A; Wang, Lili; Bigos, Martin; Nolan, John P

    2012-09-01

    Results from a standardization study cosponsored by the International Society for Advancement of Cytometry (ISAC) and the US National Institute of Standards and Technology (NIST) are reported. The study evaluated the variability of assigning intensity values to fluorophore standard beads by bead manufacturers and the variability of cross calibrating the standard beads to stained polymer beads (hard-dyed beads) using different flow cytometers. Hard dyed beads are generally not spectrally matched to the fluorophores used to stain cells, and spectral response varies among flow cytometers. Thus if hard dyed beads are used as fluorescence calibrators, one expects calibration for specific fluorophores (e.g., FITC or PE) to vary among different instruments. Using standard beads surface-stained with specific fluorophores (FITC, PE, APC, and Pacific Blue™), the study compared the measured intensity of fluorophore standard beads to that of hard dyed beads through cross calibration on 133 different flow cytometers. Using robust CV as a measure of variability, the variation of cross calibrated values was typically 20% or more for a particular hard dyed bead in a specific detection channel. The variation across different instrument models was often greater than the variation within a particular instrument model. As a separate part of the study, NIST and four bead manufacturers used a NIST supplied protocol and calibrated fluorophore solution standards to assign intensity values to the fluorophore beads. Values assigned to the reference beads by different groups varied by orders of magnitude in most cases, reflecting differences in instrumentation used to perform the calibration. The study concluded that the use of any spectrally unmatched hard dyed bead as a general fluorescence calibrator must be verified and characterized for every particular instrument model. Close interaction between bead manufacturers and NIST is recommended to have reliable and uniformly assigned

  6. Allan deviation analysis of financial return series

    NASA Astrophysics Data System (ADS)

    Hernández-Pérez, R.

    2012-05-01

    We perform a scaling analysis for the return series of different financial assets applying the Allan deviation (ADEV), which is used in the time and frequency metrology to characterize quantitatively the stability of frequency standards since it has demonstrated to be a robust quantity to analyze fluctuations of non-stationary time series for different observation intervals. The data used are opening price daily series for assets from different markets during a time span of around ten years. We found that the ADEV results for the return series at short scales resemble those expected for an uncorrelated series, consistent with the efficient market hypothesis. On the other hand, the ADEV results for absolute return series for short scales (first one or two decades) decrease following approximately a scaling relation up to a point that is different for almost each asset, after which the ADEV deviates from scaling, which suggests that the presence of clustering, long-range dependence and non-stationarity signatures in the series drive the results for large observation intervals.

  7. Blood thiamine values in captive adult African lions (Panthera leo).

    PubMed

    Hoover, John P; DiGesualdo, Cynthia L

    2005-09-01

    Heparinized whole-blood samples from 22 adult African lions (Panthera leo) fed diets considered nutritionally adequate in 10 American Zoo and Aquarium Association member zoos in North America were provided for this study. Blood thiamine values were estimated using a standard microbiological assay method. The mean +/- standard deviation for blood thiamine values was 249.3 +/- 43.5 nmol/L with a range in values from 160 to 350 nmol/L after exclusion of one outlier. There were no differences (P > 0.05) in the mean blood thiamine values of male and female lions, or of lions that were over and under 10 yr of age. This range (160 to 350 nmol/L) is proposed as a reasonable estimate of the expected range in blood thiamine values for captive adult African lions as currently fed in North American zoos.

  8. Constraints on deviations from ΛCDM within Horndeski gravity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bellini, Emilio; Cuesta, Antonio J.; Jimenez, Raul

    2016-02-01

    Recent anomalies found in cosmological datasets such as the low multipoles of the Cosmic Microwave Background or the low redshift amplitude and growth of clustering measured by e.g., abundance of galaxy clusters and redshift space distortions in galaxy surveys, have motivated explorations of models beyond standard ΛCDM. Of particular interest are models where general relativity (GR) is modified on large cosmological scales. Here we consider deviations from ΛCDM+GR within the context of Horndeski gravity, which is the most general theory of gravity with second derivatives in the equations of motion. We adopt a parametrization in which the four additional Horndeskimore » functions of time α{sub i}(t) are proportional to the cosmological density of dark energy Ω{sub DE}(t). Constraints on this extended parameter space using a suite of state-of-the art cosmological observations are presented for the first time. Although the theory is able to accommodate the low multipoles of the Cosmic Microwave Background and the low amplitude of fluctuations from redshift space distortions, we find no significant tension with ΛCDM+GR when performing a global fit to recent cosmological data and thus there is no evidence against ΛCDM+GR from an analysis of the value of the Bayesian evidence ratio of the modified gravity models with respect to ΛCDM, despite introducing extra parameters. The posterior distribution of these extra parameters that we derive return strong constraints on any possible deviations from ΛCDM+GR in the context of Horndeski gravity. We illustrate how our results can be applied to a more general frameworks of modified gravity models.« less

  9. [Study on physical deviation factors on laser induced breakdown spectroscopy measurement].

    PubMed

    Wan, Xiong; Wang, Peng; Wang, Qi; Zhang, Qing; Zhang, Zhi-Min; Zhang, Hua-Ming

    2013-10-01

    In order to eliminate the deviation between the measured LIBS spectral line and the standard LIBS spectral line, and improve the accuracy of elements measurement, a research of physical deviation factors in laser induced breakdown spectroscopy technology was proposed. Under the same experimental conditions, the relationship of ablated hole effect and spectral wavelength was tested, the Stark broadening data of Mg plasma laser induced breakdown spectroscopy with sampling time-delay from 1.00 to 3.00 micros was also studied, thus the physical deviation influences such as ablated hole effect and Stark broadening could be obtained while collecting the spectrum. The results and the method of the research and analysis can also be applied to other laser induced breakdown spectroscopy experiment system, which is of great significance to improve the accuracy of LIBS elements measuring and is also important to the research on the optimum sampling time-delay of LIBS.

  10. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.

    PubMed

    Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi

    2013-07-01

    Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and

  11. 41 CFR 102-38.30 - How does an executive agency request a deviation from the provisions of this part?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... which are distinct from the standard deviation process and specific to the requirements of the Federal... agency request a deviation from the provisions of this part? 102-38.30 Section 102-38.30 Public Contracts... executive agency request a deviation from the provisions of this part? Refer to §§ 102-2.60 through 102-2...

  12. 21 CFR 600.14 - Reporting of biological product deviations by licensed manufacturers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... this section? (1) You, the manufacturer who holds the biological product license and who had control... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Reporting of biological product deviations by... HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS BIOLOGICAL PRODUCTS: GENERAL Establishment Standards...

  13. 48 CFR 2501.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 2501.403 Section 2501.403 Federal Acquisition Regulations System NATIONAL SCIENCE FOUNDATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations From the FAR 2501.403 Individual deviations. Individual...

  14. 48 CFR 1.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...

  15. 48 CFR 1.403 - Individual deviations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...

  16. 48 CFR 1.403 - Individual deviations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...

  17. 48 CFR 3401.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations. 3401.403 Section 3401.403 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Deviations 3401.403 Individual deviations. An individual...

  18. Difference of refraction values between standard autorefractometry and Plusoptix.

    PubMed

    Bogdănici, Camelia Margareta; Săndulache, Codrina Maria; Vasiliu, Rodica; Obadă, Otilia

    2016-01-01

    Aim: Comparison between the objective refraction measurement results determined with Topcon KR-8900 standard autorefractometer and Plusoptix A09 photo-refractometer in children. Material and methods: A prospective transversal study was performed in the Department of Ophthalmology of "Sf. Spiridon" Hospital in Iași on 90 eyes of 45 pediatric patients, with a mean age of 8,82 ± 3,52 years, examined with noncycloplegic measurements provided by Plusoptix A09 and cycloplegic and noncycloplegic measurements provided by Topcon KR-8900 standard autorefractometer. The clinical parameters compared were the following: spherical equivalent (SE), spherical and cylindrical values, and cylinder axis. Astigmatism was recorded and evaluated with the cylindrical value on minus after transposition. The statistical calculation was performed with paired t-tests and Pearson's correlation analysis. All the data were analyzed with SPSS statistical package 19 (SPSS for Windows, Chicago, IL). Results: Plusoptix A09 noncycloplegic values were relatively equal between the eyes, with slightly lower values compared to noncycloplegic auto refractometry. Mean (± SD) measurements provided by Plusoptix AO9 were the following: spherical power 1.11 ± 1.52, cylindrical power 0.80 ± 0.80, and spherical equivalent 0.71 ± 1.39. The noncycloplegic auto refractometer mean (± SD) measurements were spherical power 1.12 ± 1.63, cylindrical power 0.79 ± 0,77 and spherical equivalent 0.71 ± 1.58. The cycloplegic auto refractometer mean (± SD) measurements were spherical power 2.08 ± 1.95, cylindrical power 0,82 ± 0.85 and spherical equivalent 1.68 ± 1.87. 32% of the eyes were hyperopic, 2.67% were myopic, 65.33% had astigmatism, and 30% eyes had amblyopia. Conclusions: Noncycloplegic objective refraction values were similar with those determined by autorefractometry. Plusoptix had an important role in the ophthalmological screening, but did not detect higher refractive errors, justifying the

  19. Accounting for body size deviations when reporting bone mineral density variables in children.

    PubMed

    Webber, C E; Sala, A; Barr, R D

    2009-01-01

    In a child, bone mineral density (BMD) may differ from an age-expected normal value, not only because of the presence of disease, but also because of deviations of height or weight from population averages. Appropriate adjustment for body size deviations simplifies interpretation of BMD measurements. For children, a bone mineral density (BMD) measurement is normally expressed as a Z score. Interpretation is complicated when weight or height distinctly differ from age-matched children. We develop a procedure to allow for the influence of body size deviations upon measured BMD. We examined the relation between body size deviation and spine, hip and whole body BMD deviation in 179 normal children (91 girls). Expressions were developed that allowed derivation of an expected BMD based on age, gender and body size deviation. The difference between measured and expected BMD was expressed as a HAW score (Height-, Age-, Weight-adjusted score). In a second independent sample of 26 normal children (14 girls), measured spine, total femur and whole body BMD all fell within the same single normal range after accounting for age, gender and body size deviations. When traditional Z scores and HAW scores were compared in 154 children, 17.5% showed differences of more than 1 unit and such differences were associated with height and weight deviations. For almost 1 in 5 children, body size deviations influence BMD to an extent that could alter clinical management.

  20. 48 CFR 601.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Individual deviations. 601.403 Section 601.403 Federal Acquisition Regulations System DEPARTMENT OF STATE GENERAL DEPARTMENT OF STATE ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 601.403 Individual deviations. The...

  1. The p-Value You Can't Buy.

    PubMed

    Demidenko, Eugene

    2016-01-02

    There is growing frustration with the concept of the p -value. Besides having an ambiguous interpretation, the p- value can be made as small as desired by increasing the sample size, n . The p -value is outdated and does not make sense with big data: Everything becomes statistically significant. The root of the problem with the p- value is in the mean comparison. We argue that statistical uncertainty should be measured on the individual, not the group, level. Consequently, standard deviation (SD), not standard error (SE), error bars should be used to graphically present the data on two groups. We introduce a new measure based on the discrimination of individuals/objects from two groups, and call it the D -value. The D -value can be viewed as the n -of-1 p -value because it is computed in the same way as p while letting n equal 1. We show how the D -value is related to discrimination probability and the area above the receiver operating characteristic (ROC) curve. The D -value has a clear interpretation as the proportion of patients who get worse after the treatment, and as such facilitates to weigh up the likelihood of events under different scenarios. [Received January 2015. Revised June 2015.].

  2. 48 CFR 201.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Individual deviations. 201.403 Section 201.403 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... Individual deviations. (1) Individual deviations, except those described in 201.402(1) and paragraph (2) of...

  3. 48 CFR 2801.404 - Class deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Class deviations. 2801.404 Section 2801.404 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE General DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Deviations From the FAR and JAR 2801.404 Class deviations. Requests...

  4. New Assignment of Mass Values and Uncertainties to NIST Working Standards

    PubMed Central

    Davis, Richard S.

    1990-01-01

    For some time it had been suspected that values assigned to NIST working standards of mass were some 0.17 mg/kg larger than mass values based on artifacts representing mass in the International System of Units (SI). This relatively small offset, now confirmed, has had minimal scientific or technological significance. The discrepancy was removed on January 1, 1990. We document the history of the discrepancy, the studies which allow its removal, and the methods in place to limit its effect and prevent its recurrence. For routine calibrations, we believe that our working standards now have a long-term stability of 0.033 mg/kg (3σ) with respect to the national prototype kilograms of the United States. We provisionally admit an additional uncertainty of 0.09 mg/kg (3σ), systematic to all NIST mass measurements, which represents the possible offset of our primary standards from standards maintained by the Bureau International des Poids et Mesures (BIPM). This systematic uncertainty may be significantly reduced after analysis of results from the 3rd verification of national prototype kilograms, which is now underway. PMID:28179759

  5. A Fixed-Pattern Noise Correction Method Based on Gray Value Compensation for TDI CMOS Image Sensor.

    PubMed

    Liu, Zhenwang; Xu, Jiangtao; Wang, Xinlei; Nie, Kaiming; Jin, Weimin

    2015-09-16

    In order to eliminate the fixed-pattern noise (FPN) in the output image of time-delay-integration CMOS image sensor (TDI-CIS), a FPN correction method based on gray value compensation is proposed. One hundred images are first captured under uniform illumination. Then, row FPN (RFPN) and column FPN (CFPN) are estimated based on the row-mean vector and column-mean vector of all collected images, respectively. Finally, RFPN are corrected by adding the estimated RFPN gray value to the original gray values of pixels in the corresponding row, and CFPN are corrected by subtracting the estimated CFPN gray value from the original gray values of pixels in the corresponding column. Experimental results based on a 128-stage TDI-CIS show that, after correcting the FPN in the image captured under uniform illumination with the proposed method, the standard-deviation of row-mean vector decreases from 5.6798 to 0.4214 LSB, and the standard-deviation of column-mean vector decreases from 15.2080 to 13.4623 LSB. Both kinds of FPN in the real images captured by TDI-CIS are eliminated effectively with the proposed method.

  6. Toddle temporal-spatial deviation index: Assessment of pediatric gait.

    PubMed

    Cahill-Rowley, Katelyn; Rose, Jessica

    2016-09-01

    This research aims to develop a gait index for use in the pediatric clinic as well as research, that quantifies gait deviation in 18-22 month-old children: the Toddle Temporal-spatial Deviation Index (Toddle TDI). 81 preterm children (≤32 weeks) with very-low-birth-weights (≤1500g) and 42 full-term TD children aged 18-22 months, adjusted for prematurity, walked on a pressure-sensitive mat. Preterm children were administered the Bayley Scales of Infant Development-3rd Edition (BSID-III). Principle component analysis of TD children's temporal-spatial gait parameters quantified raw gait deviation from typical, normalized to an average(standard deviation) Toddle TDI score of 100(10), and calculated for all participants. The Toddle TDI was significantly lower for preterm versus TD children (86 vs. 100, p=0.003), and lower in preterm children with <85 vs. ≥85 BSID-III motor composite scores (66 vs. 89, p=0.004). The Toddle TDI, which by design plateaus at typical average (BSID-III gross motor 8-12), correlated with BSID-III gross motor (r=0.60, p<0.001) and not fine motor (r=0.08, p=0.65) in preterm children with gross motor scores ≤8, suggesting sensitivity to gross motor development. The Toddle TDI demonstrated sensitivity and specificity to gross motor function in very-low-birth-weight preterm children aged 18-22 months, and has been potential as an easily-administered, revealing clinical gait metric. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. 48 CFR 3001.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations... from the FAR and HSAR 3001.403 Individual deviations. Unless precluded by law, executive order, or other regulation, the HCA is authorized to approve individual deviation (except with respect to (FAR) 48...

  8. 48 CFR 1901.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Individual deviations. 1901.403 Section 1901.403 Federal Acquisition Regulations System BROADCASTING BOARD OF GOVERNORS GENERAL... Individual deviations. Deviations from the IAAR or the FAR in individual cases shall be authorized by the...

  9. Development of a programmable standard of ultra-low capacitance values.

    PubMed

    Khan, M S; Séron, O; Thuillier, G; Thévenot, O; Gournay, P; Piquemal, F

    2017-05-01

    A set of ultra-low value capacitance standards together with a programmable coaxial multiplexer (mux) have been developed. The mux allows the connection of these capacitances in parallel configuration and they together form the programmable capacitance standard. It is capable of producing decadic standard capacitances from 10 aF to at least 0.1 pF, which are later used to calibrate commercial precision capacitance bridges. This paper describes the realization and the characterization of this standard together with results obtained during the calibration of Andeen-Hagerling AH2700A bridges with a maximum uncertainty of 0.8 aF for all the capacitances generated ranging from 10 aF to 0.1 pF, at 1 kHz. These latter could be then integrated to functionalized AFMs or probe stations for quantitative capacitance measurements. Sources of uncertainties of the programmable capacitance standard, such as parasitic effects due to stray impedances, are evaluated and a method to overcome these hindrances is also discussed.

  10. Radiographic evaluation of nasal septal deviation from computed tomography correlates poorly with physical exam findings.

    PubMed

    Sedaghat, Ahmad R; Kieff, David A; Bergmark, Regan W; Cunnane, Mary E; Busaba, Nicolas Y

    2015-03-01

    Performance of septoplasty is dependent on objective evidence of nasal septal deviation. Although physical examination including anterior rhinoscopy and endoscopic examination is the gold standard for evaluation of septal deviation, third-party payors' reviews of septoplasty claims are often made on computed tomography (CT) findings. However, the correlation between radiographic evaluation of septal deviation with physical examination findings is unknown. Retrospective, blinded, independent evaluation of septal deviation in 39 consecutive patients from physical examination, including anterior rhinoscopy and endoscopic examination, by an otolaryngologist and radiographic evaluation of sinus CT scan by a neuroradiologist. Four distinct septal locations (nasal valve, cartilaginous, inferior/maxillary crest and osseous septum) were evaluated on a 4-point scale representing (1) 0% to 25%, (2) >25% to 50%, (3) >50% to 75%, and (4) >75% obstruction. Correlation between physical examination and radiographic evaluations was made by Pearson's correlation and quantitative agreement assessed by Krippendorf's alpha. Statistically significant correlation was detected between physical examination including nasal endoscopy and radiographic assessment of septal deviation only at the osseous septum (p = 0.007, r = 0.425) with low quantitative agreement (α = 0.290). No significant correlation was detected at the cartilaginous septum (p = 0.286, r = 0.175), inferior septum (p = 0.117, r = 0.255), or nasal valve (p = 0.174, r = 0.222). Quantitative agreement at the nasal valve suggested a bias in CT to underestimate physical exam findings (α = -0.490). CT is a poor substitute for physical examination, the gold standard, in assessment of septal deviation. Clinical decisions about pursuit of septoplasty or third-party payors' decisions to approve septoplasty should not be made on radiographic evidence. © 2014 ARS-AAOA, LLC.

  11. Deviation Management: Key Management Subsystem Driver of Knowledge-Based Continuous Improvement in the Henry Ford Production System.

    PubMed

    Zarbo, Richard J; Copeland, Jacqueline R; Varney, Ruan C

    2017-10-01

    To develop a business subsystem fulfilling International Organization for Standardization 15189 nonconformance management regulatory standard, facilitating employee engagement in problem identification and resolution to effect quality improvement and risk mitigation. From 2012 to 2016, the integrated laboratories of the Henry Ford Health System used a quality technical team to develop and improve a management subsystem designed to identify, track, trend, and summarize nonconformances based on frequency, risk, and root cause for elimination at the level of the work. Programmatic improvements and training resulted in markedly increased documentation culminating in 71,641 deviations in 2016 classified by a taxonomy of 281 defect types into preanalytic (74.8%), analytic (23.6%), and postanalytic (1.6%) testing phases. The top 10 deviations accounted for 55,843 (78%) of the total. Deviation management is a key subsystem of managers' standard work whereby knowledge of nonconformities assists in directing corrective actions and continuous improvements that promote consistent execution and higher levels of performance. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  12. Variance component and breeding value estimation for genetic heterogeneity of residual variance in Swedish Holstein dairy cattle.

    PubMed

    Rönnegård, L; Felleki, M; Fikse, W F; Mulder, H A; Strandberg, E

    2013-04-01

    Trait uniformity, or micro-environmental sensitivity, may be studied through individual differences in residual variance. These differences appear to be heritable, and the need exists, therefore, to fit models to predict breeding values explaining differences in residual variance. The aim of this paper is to estimate breeding values for micro-environmental sensitivity (vEBV) in milk yield and somatic cell score, and their associated variance components, on a large dairy cattle data set having more than 1.6 million records. Estimation of variance components, ordinary breeding values, and vEBV was performed using standard variance component estimation software (ASReml), applying the methodology for double hierarchical generalized linear models. Estimation using ASReml took less than 7 d on a Linux server. The genetic standard deviations for residual variance were 0.21 and 0.22 for somatic cell score and milk yield, respectively, which indicate moderate genetic variance for residual variance and imply that a standard deviation change in vEBV for one of these traits would alter the residual variance by 20%. This study shows that estimation of variance components, estimated breeding values and vEBV, is feasible for large dairy cattle data sets using standard variance component estimation software. The possibility to select for uniformity in Holstein dairy cattle based on these estimates is discussed. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Eddy heat flux across the Antarctic Circumpolar Current estimated from sea surface height standard deviation

    NASA Astrophysics Data System (ADS)

    Foppert, Annie; Donohue, Kathleen A.; Watts, D. Randolph; Tracey, Karen L.

    2017-08-01

    Eddy heat flux (EHF) is a predominant mechanism for heat transport across the zonally unbounded mean flow of the Antarctic Circumpolar Current (ACC). Observations of dynamically relevant, divergent, 4 year mean EHF in Drake Passage from the cDrake project, as well as previous studies of atmospheric and oceanic storm tracks, motivates the use of sea surface height (SSH) standard deviation, H*, as a proxy for depth-integrated, downgradient, time-mean EHF (>[EHF>¯>]) in the ACC. Statistics from the Southern Ocean State Estimate corroborate this choice and validate throughout the ACC the spatial agreement between H* and >[EHF>¯>] seen locally in Drake Passage. Eight regions of elevated >[EHF>¯>] are identified from nearly 23.5 years of satellite altimetry data. Elevated cross-front exchange usually does not span the full latitudinal width of the ACC in each region, implying a hand-off of heat between ACC fronts and frontal zones as they encounter the different >[EHF>¯>] hot spots along their circumpolar path. Integrated along circumpolar streamlines, defined by mean SSH contours, there is a convergence of >[EHF>¯>] in the ACC: 1.06 PW enters from the north and 0.02 PW exits to the south. Temporal trends in low-frequency [EHF] are calculated in a running-mean sense using H* from overlapping 4 year subsets of SSH. Significant increases in downgradient [EHF] magnitude have occurred since 1993 at Kerguelen Plateau, Southeast Indian Ridge, and the Brazil-Malvinas Confluence, whereas the other five >[EHF>¯>] hot spots have insignificant trends of varying sign.

  14. 49 CFR 192.943 - When can an operator deviate from these reassessment intervals?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.943 When can an operator deviate from these reassessment...

  15. Standard-b-Value Versus Low-b-Value Diffusion-Weighted Imaging in Hepatic Lesion Discrimination: A Meta-analysis.

    PubMed

    Xiong, Hui; Zeng, Yuan-Lin

    2016-01-01

    We sought to determine the comparative diagnostic performance of standard-b-value (500-1000s/mm) versus low-b-value (≤500 s/mm) diffusion-weighted imaging (DWI) in the discrimination of hepatic lesions. A total of 1775 hepatic malignant lesions and 1120 benign hepatic lesions from 21 studies were included. (1) The global sensitivity was 0.86 (95% confidence interval [CI], 0.847-0.879), the specificity was 0.82 (95% CI, 0.797-0.842), the positive likelihood ratio (PLR) was 6.234 (95% CI, 4.260-9.123), the negative likelihood ratio (NLR) was 0.175 (95% CI, 0.135-0.227), and diagnostic odds ratio (DOR) was 42.836 (95% CI, 24.134-76.031). The area under the curve (AUC) and Q* index were 0.93 and 0.87. Publication bias was not present (P > 0.05). (2)The sensitivity of a subgroup meta-analysis of standard-b-value DWI was 0.858 (95% CI, 0.835-0.880), the specificity was 0.836 (95% CI, 0.807-0.863), the PLR was 6.527 (95% CI, 3.857-11.046), the NLR was 0.168 (95% CI, 0.123-0.239), and the DOR was 49.716 (95% CI, 22.897-107.98). The AUC and Q* index were 0.941 and 0.88. (3)The sensitivity of a subgroup meta-analysis of low-b-value DWI was 0.87 (95% CI, 0.84-0.89), the specificity was 0.80 (95% CI, 0.76-0.83), the PLR was 6.22 (95% CI, 3.29-11.76), the NLR was 0.19 (95% CI, 0.12-0.29), and the DOR was 37.14 (95% CI, 14.80-93.18). The AUC and Q* index were 0.922 and 0.86. Hepatic DWI is useful in differentiating between malignant and benign hepatic lesions. Standard-b-value DWI displayed an overall superior diagnostic accuracy over low-b-value DWI. Further trials needed to determine whether increasing b values beyond 1000 s/mm affects the diagnostic accuracy of hepatic lesion discrimination.

  16. Assessing the Added Value of Dynamical Downscaling Using the Standardized Precipitation Index

    EPA Science Inventory

    In this study, the Standardized Precipitation Index (SPI) is used to ascertain the added value of dynamical downscaling over the contiguous United States. WRF is used as a regional climate model (RCM) to dynamically downscale reanalysis fields to compare values of SPI over drough...

  17. Large deviations and portfolio optimization

    NASA Astrophysics Data System (ADS)

    Sornette, Didier

    Risk control and optimal diversification constitute a major focus in the finance and insurance industries as well as, more or less consciously, in our everyday life. We present a discussion of the characterization of risks and of the optimization of portfolios that starts from a simple illustrative model and ends by a general functional integral formulation. A major item is that risk, usually thought of as one-dimensional in the conventional mean-variance approach, has to be addressed by the full distribution of losses. Furthermore, the time-horizon of the investment is shown to play a major role. We show the importance of accounting for large fluctuations and use the theory of Cramér for large deviations in this context. We first treat a simple model with a single risky asset that exemplifies the distinction between the average return and the typical return and the role of large deviations in multiplicative processes, and the different optimal strategies for the investors depending on their size. We then analyze the case of assets whose price variations are distributed according to exponential laws, a situation that is found to describe daily price variations reasonably well. Several portfolio optimization strategies are presented that aim at controlling large risks. We end by extending the standard mean-variance portfolio optimization theory, first within the quasi-Gaussian approximation and then using a general formulation for non-Gaussian correlated assets in terms of the formalism of functional integrals developed in the field theory of critical phenomena.

  18. Welding deviation detection algorithm based on extremum of molten pool image contour

    NASA Astrophysics Data System (ADS)

    Zou, Yong; Jiang, Lipei; Li, Yunhua; Xue, Long; Huang, Junfen; Huang, Jiqiang

    2016-01-01

    The welding deviation detection is the basis of robotic tracking welding, but the on-line real-time measurement of welding deviation is still not well solved by the existing methods. There is plenty of information in the gas metal arc welding(GMAW) molten pool images that is very important for the control of welding seam tracking. The physical meaning for the curvature extremum of molten pool contour is revealed by researching the molten pool images, that is, the deviation information points of welding wire center and the molten tip center are the maxima and the local maxima of the contour curvature, and the horizontal welding deviation is the position difference of these two extremum points. A new method of weld deviation detection is presented, including the process of preprocessing molten pool images, extracting and segmenting the contours, obtaining the contour extremum points, and calculating the welding deviation, etc. Extracting the contours is the premise, segmenting the contour lines is the foundation, and obtaining the contour extremum points is the key. The contour images can be extracted with the method of discrete dyadic wavelet transform, which is divided into two sub contours including welding wire and molten tip separately. The curvature value of each point of the two sub contour lines is calculated based on the approximate curvature formula of multi-points for plane curve, and the two points of the curvature extremum are the characteristics needed for the welding deviation calculation. The results of the tests and analyses show that the maximum error of the obtained on-line welding deviation is 2 pixels(0.16 mm), and the algorithm is stable enough to meet the requirements of the pipeline in real-time control at a speed of less than 500 mm/min. The method can be applied to the on-line automatic welding deviation detection.

  19. T-wave axis deviation and left ventricular hypertrophy interaction in diabetes and hypertension.

    PubMed

    Assanelli, Deodato; Di Castelnuovo, Augusto; Rago, Livia; Badilini, Fabio; Vinetti, Giovanni; Gianfagna, Francesco; Salvetti, Massimo; Zito, Francesco; Donati, Maria Benedetta; de Gaetano, Giovanni; Iacoviello, Licia

    2013-01-01

    Electrocardiographic signs of left ventricular hypertrophy (ECG-LVH) and T-wave axis (TA) deviation are independent predictors of fatal and non fatal events. We assessed the prevalence of ECG-LVH, TA abnormalities and their combination according to the presence or absence of diabetes and/or hypertension in a large sample of the adult general Italian population. Data from 10,184 women (54 ± 11 years) and 8775 men (54 ± 11 years) were analyzed from the Moli-sani cohort, a database of randomly recruited adults (age >35) from the general population of Molise, a central region of Italy that includes collection of standard 12-lead resting ECG. Subjects with previous myocardial infarction, angina, cerebrovascular disease or left bundle brunch block or missing values for TA or ECG-LVH have been excluded. TA was measured from the standard 12-lead ECG and it was defined as the rotation of the T wave in the frontal plane as computed by a proprietary algorithm (CalECG/Bravo, AMPS-LLC, NY). ECG-LVH was defined as Sokolow Lyon voltage (SLv) >35 mm or Cornell voltage duration Product (CP) >= 2440 mm*ms. Among subjects with ECG-LVH, prevalence of hypertension was 59.0% and 49.7%, respectively for men and women, whereas that of diabetes was 10.7% and 5.7%. In hypertensives, TA was normal in 72.3% of subjects, borderline in 24.8% and abnormal in 2.9%. In diabetics, TA was normal in 70.4% of subjects, borderline in 26.5% and abnormal in 3.1%. In both hypertensive and diabetic subjects, the prevalence of ECG-LVH, was significantly greater in subjects with borderline or abnormal TA. Hypertension was an independent predictor of abnormal TA (odd ratio: 1.38, P = .025). These results suggest that hypertension might play a relevant role in the pathogenesis of TA deviation. © 2013.

  20. Finding new pathway-specific regulators by clustering method using threshold standard deviation based on DNA chip data of Streptomyces coelicolor.

    PubMed

    Yang, Yung-Hun; Kim, Ji-Nu; Song, Eunjung; Kim, Eunjung; Oh, Min-Kyu; Kim, Byung-Gee

    2008-09-01

    In order to identify the regulators involved in antibiotic production or time-specific cellular events, the messenger ribonucleic acid (mRNA) expression data of the two gene clusters, actinorhodin (ACT) and undecylprodigiosin (RED) biosynthetic genes, were clustered with known mRNA expression data of regulators from S. coelicolor using a filtering method based on standard deviation and clustering analysis. The result identified five regulators including two well-known regulators namely, SCO3579 (WlbA) and SCO6722 (SsgD). Using overexpression and deletion of the regulator genes, we were able to identify two regulators, i.e., SCO0608 and SCO6808, playing roles as repressors in antibiotics production and sporulation. This approach can be easily applied to mapping out new regulators related to any interesting target gene clusters showing characteristic expression patterns. The result can also be used to provide insightful information on the selection rules among a large number of regulators.

  1. The role of Nesbit's procedure in surgical reconstruction of penile deviation

    PubMed Central

    Martenstein, Christian; Peruth, Julia; Hamza, Amir

    2012-01-01

    Objective: We review our results after surgical reconstruction with the Nesbit’s procedure for congenital or acquired penile deviation. Patients and methods: Etiology of penile deviation, surgical outcome for straightening the penis, postoperative patient satisfaction and clinical findings were evaluated for 5 patients undergoing Nesbit’s procedure followed by a Medline review of contemporary literature regarding alternative surgical techniques. Follow-up included clinical examination, self-photography on erection and a standardized interview with erectile dysfunction assessment using IIEF-5 questionnaire. Results: Overall patient satisfaction was 100% in two patients, 2 patients were partly satisfied and 1 patient reported no satisfaction because of severe penile shortening with insufficiency for sexual intercourse postoperatively. Preoperative mean angulation of the penis was 42°. Four patients had Peyronie’s disease and 1 patient’s curvature resulted from an untreated penile fracture during sexual intercourse. Conclusion: The Nesbit technique can give satisfactory results for mild and moderate penile curvature. However, each technique for the reconstruction of penile deviation has its own advantages and disadvantages. Therefore proper patient selection has a major impact on further outcome. PMID:26504690

  2. 7 CFR 2502.3 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Deviations. 2502.3 Section 2502.3 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF ADVOCACY AND OUTREACH, DEPARTMENT OF AGRICULTURE AGRICULTURAL CAREER AND EMPLOYMENT (ACE) GRANTS PROGRAM General Information § 2502.3 Deviations...

  3. 7 CFR 2502.3 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Deviations. 2502.3 Section 2502.3 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF ADVOCACY AND OUTREACH, DEPARTMENT OF AGRICULTURE AGRICULTURAL CAREER AND EMPLOYMENT (ACE) GRANTS PROGRAM General Information § 2502.3 Deviations...

  4. 7 CFR 2502.3 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Deviations. 2502.3 Section 2502.3 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF ADVOCACY AND OUTREACH, DEPARTMENT OF AGRICULTURE AGRICULTURAL CAREER AND EMPLOYMENT (ACE) GRANTS PROGRAM General Information § 2502.3 Deviations...

  5. The Relation of White-on-White Standard Automated Perimetry, Short Wavelength Perimetry, and Optic Coherence Tomography Parameters in Ocular Hypertension.

    PubMed

    Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan

    2016-12-01

    The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.

  6. Entanglement transitions induced by large deviations

    NASA Astrophysics Data System (ADS)

    Bhosale, Udaysinh T.

    2017-12-01

    The probability of large deviations of the smallest Schmidt eigenvalue for random pure states of bipartite systems, denoted as A and B , is computed analytically using a Coulomb gas method. It is shown that this probability, for large N , goes as exp[-β N2Φ (ζ ) ] , where the parameter β is the Dyson index of the ensemble, ζ is the large deviation parameter, while the rate function Φ (ζ ) is calculated exactly. Corresponding equilibrium Coulomb charge density is derived for its large deviations. Effects of the large deviations of the extreme (largest and smallest) Schmidt eigenvalues on the bipartite entanglement are studied using the von Neumann entropy. Effect of these deviations is also studied on the entanglement between subsystems 1 and 2, obtained by further partitioning the subsystem A , using the properties of the density matrix's partial transpose ρ12Γ. The density of states of ρ12Γ is found to be close to the Wigner's semicircle law with these large deviations. The entanglement properties are captured very well by a simple random matrix model for the partial transpose. The model predicts the entanglement transition across a critical large deviation parameter ζ . Log negativity is used to quantify the entanglement between subsystems 1 and 2. Analytical formulas for it are derived using the simple model. Numerical simulations are in excellent agreement with the analytical results.

  7. Entanglement transitions induced by large deviations.

    PubMed

    Bhosale, Udaysinh T

    2017-12-01

    The probability of large deviations of the smallest Schmidt eigenvalue for random pure states of bipartite systems, denoted as A and B, is computed analytically using a Coulomb gas method. It is shown that this probability, for large N, goes as exp[-βN^{2}Φ(ζ)], where the parameter β is the Dyson index of the ensemble, ζ is the large deviation parameter, while the rate function Φ(ζ) is calculated exactly. Corresponding equilibrium Coulomb charge density is derived for its large deviations. Effects of the large deviations of the extreme (largest and smallest) Schmidt eigenvalues on the bipartite entanglement are studied using the von Neumann entropy. Effect of these deviations is also studied on the entanglement between subsystems 1 and 2, obtained by further partitioning the subsystem A, using the properties of the density matrix's partial transpose ρ_{12}^{Γ}. The density of states of ρ_{12}^{Γ} is found to be close to the Wigner's semicircle law with these large deviations. The entanglement properties are captured very well by a simple random matrix model for the partial transpose. The model predicts the entanglement transition across a critical large deviation parameter ζ. Log negativity is used to quantify the entanglement between subsystems 1 and 2. Analytical formulas for it are derived using the simple model. Numerical simulations are in excellent agreement with the analytical results.

  8. The prognostic value of standardized reference values for speckle-tracking global longitudinal strain in hypertrophic cardiomyopathy.

    PubMed

    Hartlage, Gregory R; Kim, Jonathan H; Strickland, Patrick T; Cheng, Alan C; Ghasemzadeh, Nima; Pernetz, Maria A; Clements, Stephen D; Williams, B Robinson

    2015-03-01

    Speckle-tracking left ventricular global longitudinal strain (GLS) assessment may provide substantial prognostic information for hypertrophic cardiomyopathy (HCM) patients. Reference values for GLS have been recently published. We aimed to evaluate the prognostic value of standardized reference values for GLS in HCM patients. An analysis of HCM clinic patients who underwent GLS was performed. GLS was defined as normal (more negative or equal to -16%) and abnormal (less negative than -16%) based on recently published reference values. Patients were followed for a composite of events including heart failure hospitalization, sustained ventricular arrhythmia, and all-cause death. The power of GLS to predict outcomes was assessed relative to traditional clinical and echocardiographic variables present in HCM. 79 HCM patients were followed for a median of 22 months (interquartile range 9-30 months) after imaging. During follow-up, 15 patients (19%) met the primary outcome. Abnormal GLS was the only echocardiographic variable independently predictive of the primary outcome [multivariate Hazard ratio 5.05 (95% confidence interval 1.09-23.4, p = 0.038)]. When combined with traditional clinical variables, abnormal GLS remained independently predictive of the primary outcome [multivariate Hazard ratio 5.31 (95 % confidence interval 1.18-24, p = 0.030)]. In a model including the strongest clinical and echocardiographic predictors of the primary outcome, abnormal GLS demonstrated significant incremental benefit for risk stratification [net reclassification improvement 0.75 (95 % confidence interval 0.21-1.23, p < 0.0001)]. Abnormal GLS is an independent predictor of adverse outcomes in HCM patients. Standardized use of GLS may provide significant incremental value over traditional variables for risk stratification.

  9. GTA weld penetration and the effects of deviations in machine variables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giedt, W.H.

    1987-07-01

    Analytical models for predicting the temperature distribution during GTA welding are reviewed with the purpose of developing a procedure for investigating the effects of deviations in machine parameters. The objective was to determine the accuracy required in machine settings to obtain reproducible results. This review revealed a wide range of published values (21 to 90%) for the arc heating efficiency. Low values (21 to 65%) were associated with evaluation of efficiency using constant property conduction models. Values from 75 to 90% were determined from calorimetric type measurements and are applicable for more accurate numerical solution procedures. Although numerical solutions canmore » yield better overall weld zone predictions, calculations are lengthy and complex. In view of this and the indication that acceptable agreement with experimental measurements can be achieved with the moving-point-source solution, it was utilized to investigate the effects of deviations or errors in voltage, current, and travel speed on GTA weld penetration. Variations resulting from welding within current goals for voltage (+-0.1 V), current (+-3.0 A), and travel speed (+-2.0%) were found to be +-2 to 4%, with voltage and current being more influential than travel speed.« less

  10. 22 CFR 226.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Deviations. 226.4 Section 226.4 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS General § 226.4 Deviations. The Office of Management and Budget (OMB) may grant exceptions for...

  11. 34 CFR 74.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Deviations. 74.4 Section 74.4 Education Office of the Secretary, Department of Education ADMINISTRATION OF GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS General § 74.4 Deviations. The Secretary, after...

  12. 22 CFR 145.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Deviations. 145.4 Section 145.4 Foreign Relations DEPARTMENT OF STATE CIVIL RIGHTS GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS General § 145.4 Deviations. The Office of Management and...

  13. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision.

    PubMed

    Liu, Jiakai; Tan, Chin Hon; Badrick, Tony; Loh, Tze Ping

    2018-02-01

    An increase in analytical imprecision (expressed as CV a ) can introduce additional variability (i.e. noise) to the patient results, which poses a challenge to the optimal management of patients. Relatively little work has been done to address the need for continuous monitoring of analytical imprecision. Through numerical simulations, we describe the use of moving standard deviation (movSD) and a recently described moving sum of outlier (movSO) patient results as means for detecting increased analytical imprecision, and compare their performances against internal quality control (QC) and the average of normal (AoN) approaches. The power of detecting an increase in CV a is suboptimal under routine internal QC procedures. The AoN technique almost always had the highest average number of patient results affected before error detection (ANPed), indicating that it had generally the worst capability for detecting an increased CV a . On the other hand, the movSD and movSO approaches were able to detect an increased CV a at significantly lower ANPed, particularly for measurands that displayed a relatively small ratio of biological variation to CV a. CONCLUSION: The movSD and movSO approaches are effective in detecting an increase in CV a for high-risk measurands with small biological variation. Their performance is relatively poor when the biological variation is large. However, the clinical risks of an increase in analytical imprecision is attenuated for these measurands as an increased analytical imprecision will only add marginally to the total variation and less likely to impact on the clinical care. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. 7 CFR 1724.52 - Permitted deviations from RUS construction standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...

  15. 7 CFR 1724.52 - Permitted deviations from RUS construction standards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...

  16. 7 CFR 1724.52 - Permitted deviations from RUS construction standards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...

  17. 7 CFR 1724.52 - Permitted deviations from RUS construction standards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...

  18. 7 CFR 1724.52 - Permitted deviations from RUS construction standards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... (b) Transformer neutral connections. Where it is necessary to separate the primary and secondary neutrals to provide the required electric service to a consumer, the RUS standard transformer secondary... economically meeting the clearance requirements of the NESC. (2) It is permissible to lower the transformer and...

  19. Expected distributions of root-mean-square positional deviations in proteins.

    PubMed

    Pitera, Jed W

    2014-06-19

    The atom positional root-mean-square deviation (RMSD) is a standard tool for comparing the similarity of two molecular structures. It is used to characterize the quality of biomolecular simulations, to cluster conformations, and as a reaction coordinate for conformational changes. This work presents an approximate analytic form for the expected distribution of RMSD values for a protein or polymer fluctuating about a stable native structure. The mean and maximum of the expected distribution are independent of chain length for long chains and linearly proportional to the average atom positional root-mean-square fluctuations (RMSF). To approximate the RMSD distribution for random-coil or unfolded ensembles, numerical distributions of RMSD were generated for ensembles of self-avoiding and non-self-avoiding random walks. In both cases, for all reference structures tested for chains more than three monomers long, the distributions have a maximum distant from the origin with a power-law dependence on chain length. The purely entropic nature of this result implies that care must be taken when interpreting stable high-RMSD regions of the free-energy landscape as "intermediates" or well-defined stable states.

  20. 78 FR 52679 - Safety Standard for Cigarette Lighters; Adjusted Customs Value for Cigarette Lighters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-26

    ... Customs Value for Cigarette Lighters AGENCY: Consumer Product Safety Commission. ACTION: Final rule... refillable lighters that use butane or similar fuels and have a Customs Value or ex-factory price below a threshold value (initially set at $2.00 in 1993). The standard provides that the initial $2.00 value adjusts...

  1. Optimal transformations leading to normal distributions of positron emission tomography standardized uptake values.

    PubMed

    Scarpelli, Matthew; Eickhoff, Jens; Cuna, Enrique; Perlman, Scott; Jeraj, Robert

    2018-01-30

    The statistical analysis of positron emission tomography (PET) standardized uptake value (SUV) measurements is challenging due to the skewed nature of SUV distributions. This limits utilization of powerful parametric statistical models for analyzing SUV measurements. An ad-hoc approach, which is frequently used in practice, is to blindly use a log transformation, which may or may not result in normal SUV distributions. This study sought to identify optimal transformations leading to normally distributed PET SUVs extracted from tumors and assess the effects of therapy on the optimal transformations. The optimal transformation for producing normal distributions of tumor SUVs was identified by iterating the Box-Cox transformation parameter (λ) and selecting the parameter that maximized the Shapiro-Wilk P-value. Optimal transformations were identified for tumor SUV max distributions at both pre and post treatment. This study included 57 patients that underwent 18 F-fluorodeoxyglucose ( 18 F-FDG) PET scans (publically available dataset). In addition, to test the generality of our transformation methodology, we included analysis of 27 patients that underwent 18 F-Fluorothymidine ( 18 F-FLT) PET scans at our institution. After applying the optimal Box-Cox transformations, neither the pre nor the post treatment 18 F-FDG SUV distributions deviated significantly from normality (P  >  0.10). Similar results were found for 18 F-FLT PET SUV distributions (P  >  0.10). For both 18 F-FDG and 18 F-FLT SUV distributions, the skewness and kurtosis increased from pre to post treatment, leading to a decrease in the optimal Box-Cox transformation parameter from pre to post treatment. There were types of distributions encountered for both 18 F-FDG and 18 F-FLT where a log transformation was not optimal for providing normal SUV distributions. Optimization of the Box-Cox transformation, offers a solution for identifying normal SUV transformations for when the log

  2. Optimal transformations leading to normal distributions of positron emission tomography standardized uptake values

    NASA Astrophysics Data System (ADS)

    Scarpelli, Matthew; Eickhoff, Jens; Cuna, Enrique; Perlman, Scott; Jeraj, Robert

    2018-02-01

    The statistical analysis of positron emission tomography (PET) standardized uptake value (SUV) measurements is challenging due to the skewed nature of SUV distributions. This limits utilization of powerful parametric statistical models for analyzing SUV measurements. An ad-hoc approach, which is frequently used in practice, is to blindly use a log transformation, which may or may not result in normal SUV distributions. This study sought to identify optimal transformations leading to normally distributed PET SUVs extracted from tumors and assess the effects of therapy on the optimal transformations. Methods. The optimal transformation for producing normal distributions of tumor SUVs was identified by iterating the Box-Cox transformation parameter (λ) and selecting the parameter that maximized the Shapiro-Wilk P-value. Optimal transformations were identified for tumor SUVmax distributions at both pre and post treatment. This study included 57 patients that underwent 18F-fluorodeoxyglucose (18F-FDG) PET scans (publically available dataset). In addition, to test the generality of our transformation methodology, we included analysis of 27 patients that underwent 18F-Fluorothymidine (18F-FLT) PET scans at our institution. Results. After applying the optimal Box-Cox transformations, neither the pre nor the post treatment 18F-FDG SUV distributions deviated significantly from normality (P  >  0.10). Similar results were found for 18F-FLT PET SUV distributions (P  >  0.10). For both 18F-FDG and 18F-FLT SUV distributions, the skewness and kurtosis increased from pre to post treatment, leading to a decrease in the optimal Box-Cox transformation parameter from pre to post treatment. There were types of distributions encountered for both 18F-FDG and 18F-FLT where a log transformation was not optimal for providing normal SUV distributions. Conclusion. Optimization of the Box-Cox transformation, offers a solution for identifying normal SUV transformations for when

  3. 32 CFR 21.645 - Deviation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Deviation. 21.645 Section 21.645 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.645 Deviation. The issuance or use of a policy or...

  4. 32 CFR 21.645 - Deviation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 1 2014-07-01 2014-07-01 false Deviation. 21.645 Section 21.645 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.645 Deviation. The issuance or use of a policy or...

  5. 32 CFR 21.645 - Deviation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Deviation. 21.645 Section 21.645 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.645 Deviation. The issuance or use of a policy or...

  6. 32 CFR 21.645 - Deviation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Deviation. 21.645 Section 21.645 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.645 Deviation. The issuance or use of a policy or...

  7. 32 CFR 21.645 - Deviation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 1 2013-07-01 2013-07-01 false Deviation. 21.645 Section 21.645 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD GRANT AND AGREEMENT REGULATIONS DoD GRANTS AND AGREEMENTS-GENERAL MATTERS Definitions § 21.645 Deviation. The issuance or use of a policy or...

  8. The effect of signal acquisition and processing choices on ApEn values: towards a "gold standard" for distinguishing effort levels from isometric force records.

    PubMed

    Forrest, Sarah M; Challis, John H; Winter, Samantha L

    2014-06-01

    Approximate entropy (ApEn) is frequently used to identify changes in the complexity of isometric force records with ageing and disease. Different signal acquisition and processing parameters have been used, making comparison or confirmation of results difficult. This study determined the effect of sampling and parameter choices by examining changes in ApEn values across a range of submaximal isometric contractions of the first dorsal interosseus. Reducing the sample rate by decimation changed both the value and pattern of ApEn values dramatically. The pattern of ApEn values across the range of effort levels was not sensitive to the filter cut-off frequency, or the criterion used to extract the section of data for analysis. The complexity increased with increasing effort levels using a fixed 'r' value (which accounts for measurement noise) but decreased with increasing effort level when 'r' was set to 0.1 of the standard deviation of force. It is recommended isometric force records are sampled at frequencies >200Hz, template length ('m') is set to 2, and 'r' set to measurement system noise or 0.1SD depending on physiological process to be distinguished. It is demonstrated that changes in ApEn across effort levels are related to changes in force gradation strategy. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Changes in deviation of absorbed dose to water among users by chamber calibration shift.

    PubMed

    Katayose, Tetsurou; Saitoh, Hidetoshi; Igari, Mitsunobu; Chang, Weishan; Hashimoto, Shimpei; Morioka, Mie

    2017-07-01

    The JSMP01 dosimetry protocol had adopted the provisional 60 Co calibration coefficient [Formula: see text], namely, the product of exposure calibration coefficient N C and conversion coefficient k D,X . After that, the absorbed dose to water D w  standard was established, and the JSMP12 protocol adopted the [Formula: see text] calibration. In this study, the influence of the calibration shift on the measurement of D w among users was analyzed. The intercomparison of the D w using an ionization chamber was annually performed by visiting related hospitals. Intercomparison results before and after the calibration shift were analyzed, the deviation of D w among users was re-evaluated, and the cause of deviation was estimated. As a result, the stability of LINAC, calibration of the thermometer and barometer, and collection method of ion recombination were confirmed. The statistical significance of standard deviation of D w was not observed, but that of difference of D w among users was observed between N C and [Formula: see text] calibration. Uncertainty due to chamber-to-chamber variation was reduced by the calibration shift, consequently reducing the uncertainty among users regarding D w . The result also pointed out uncertainty might be reduced by accurate and detailed instructions on the setup of an ionization chamber.

  10. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores.

    PubMed

    Joustra, Sjoerd D; van der Plas, Evelyn M; Goede, Joery; Oostdijk, Wilma; Delemarre-van de Waal, Henriette A; Hack, Wilfried W M; van Buuren, Stef; Wit, Jan M

    2015-06-01

    Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. The LMS method was used to calculate reference data, based on testicular volumes from ultrasonography and Prader orchidometer of 769 healthy Dutch boys aged 6 months to 19 years. We also explored the association between testicular growth and pubic hair development, and data were compared to orchidometric testicular volumes from the 1997 Dutch nationwide growth study. The LMS-smoothed reference charts showed that no revision of the definition of normal onset of male puberty - from nine to 14 years of age - was warranted. In healthy boys, the pubic hair stage SD scores corresponded with testicular volume SD scores (r = 0.394). However, testes were relatively small for pubic hair stage in Klinefelter's syndrome and relatively large in immunoglobulin superfamily member 1 deficiency syndrome. The age-corrected SD scores for testicular volume will aid in the diagnosis and follow-up of abnormalities in the timing and progression of male puberty and in research evaluations. The SD scores can be compared with pubic hair SD scores to identify discrepancies between cell functions that result in relative microorchidism or macroorchidism. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  11. Reference Values for Human Posture Measurements Based on Computerized Photogrammetry: A Systematic Review.

    PubMed

    Macedo Ribeiro, Ana Freire; Bergmann, Anke; Lemos, Thiago; Pacheco, Antônio Guilherme; Mello Russo, Maitê; Santos de Oliveira, Laura Alice; de Carvalho Rodrigues, Erika

    The main objective of this study was to review the literature to identify reference values for angles and distances of body segments related to upright posture in healthy adult women with the Postural Assessment Software (PAS/SAPO). Electronic databases (BVS, PubMed, SciELO and Scopus) were assessed using the following descriptors: evaluation, posture, photogrammetry, physical therapy, postural alignment, postural assessment, and physiotherapy. Studies that performed postural evaluation in healthy adult women with PAS/SAPO and were published in English, Portuguese and Spanish, between the years 2005 and 2014 were included. Four studies met the inclusion criteria. Data from the included studies were grouped to establish the statistical descriptors (mean, variance, and standard deviation) of the body angles and distances. A total of 29 variables were assessed (10 in the anterior views, 16 in the lateral right and left views, and 3 in the posterior views), and its respective mean and standard deviation were calculated. Reference values for the anterior and posterior views showed no symmetry between the right and left sides of the body in the frontal plane. There were also small differences in the calculated reference values for the lateral view. The proposed reference values for quantitative evaluation of the upright posture in healthy adult women estimated in the present study using PAS/SAPO could guide future studies and help clinical practice. Copyright © 2017. Published by Elsevier Inc.

  12. LD-SPatt: large deviations statistics for patterns on Markov chains.

    PubMed

    Nuel, G

    2004-01-01

    Statistics on Markov chains are widely used for the study of patterns in biological sequences. Statistics on these models can be done through several approaches. Central limit theorem (CLT) producing Gaussian approximations are one of the most popular ones. Unfortunately, in order to find a pattern of interest, these methods have to deal with tail distribution events where CLT is especially bad. In this paper, we propose a new approach based on the large deviations theory to assess pattern statistics. We first recall theoretical results for empiric mean (level 1) as well as empiric distribution (level 2) large deviations on Markov chains. Then, we present the applications of these results focusing on numerical issues. LD-SPatt is the name of GPL software implementing these algorithms. We compare this approach to several existing ones in terms of complexity and reliability and show that the large deviations are more reliable than the Gaussian approximations in absolute values as well as in terms of ranking and are at least as reliable as compound Poisson approximations. We then finally discuss some further possible improvements and applications of this new method.

  13. Assessment of the usefulness of the standardized uptake values and the radioactivity levels for the preoperative diagnosis of thyroid cancer measured by using 18F-FDG PET/CT dual-time-point imaging

    NASA Astrophysics Data System (ADS)

    Lee, Hyeon-Guck; Hong, Seong-Jong; Cho, Jae-Hwan; Han, Man-Seok; Kim, Tae-Hyung; Lee, Ik-Han

    2013-02-01

    The purpose of this study was to assess and compare the changes in the SUV (standardized uptake value), the 18F-FDG (18F-fluorodeoxyglucose) uptake pattern, and the radioactivity level for the diagnosis of thyroid cancer via dual-time-point 18F-FDG PET/CT (positron emission tomographycomputed tomography) imaging. Moreover, the study aimed to verify the usefulness and significance of SUV values and radioactivity levels to discriminate tumor malignancy. A retrospective analysis was performed on 40 patients who received 18F-FDG PET/CT for thyroid cancer as a primary tumor. To set the background, we compared changes in values by calculating the dispersion of scattered rays in the neck area and the lung apex, and by comparing the mean and SD (standard deviation) values of the maxSUV and the radioactivity levels. According to the statistical analysis of the changes in 18F-FDG uptake for the diagnosis of thyroid cancer, a high similarity was observed with the coefficient of determination being R2 = 0.939, in the SUVs and the radioactivity levels. Moreover, similar results were observed in the assessment of tumor malignancy using dual-time-point. The quantitative analysis method for assessing tumor malignancy using radioactivity levels was neither specific nor discriminative compared to the semi-quantitative analysis method.

  14. 9 CFR 318.308 - Deviations in processing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Deviations in processing (or process deviations) must be handled according to: (1)(i) A HACCP plan for canned...) of this section. (c) [Reserved] (d) Procedures for handling process deviations where the HACCP plan... accordance with the following procedures: (a) Emergency stops. (1) When retort jams or breakdowns occur...

  15. Estimating the probability that the sample mean is within a desired fraction of the standard deviation of the true mean.

    PubMed

    Schillaci, Michael A; Schillaci, Mario E

    2009-02-01

    The use of small sample sizes in human and primate evolutionary research is commonplace. Estimating how well small samples represent the underlying population, however, is not commonplace. Because the accuracy of determinations of taxonomy, phylogeny, and evolutionary process are dependant upon how well the study sample represents the population of interest, characterizing the uncertainty, or potential error, associated with analyses of small sample sizes is essential. We present a method for estimating the probability that the sample mean is within a desired fraction of the standard deviation of the true mean using small (n<10) or very small (n < or = 5) sample sizes. This method can be used by researchers to determine post hoc the probability that their sample is a meaningful approximation of the population parameter. We tested the method using a large craniometric data set commonly used by researchers in the field. Given our results, we suggest that sample estimates of the population mean can be reasonable and meaningful even when based on small, and perhaps even very small, sample sizes.

  16. Probability Distribution Estimated From the Minimum, Maximum, and Most Likely Values: Applied to Turbine Inlet Temperature Uncertainty

    NASA Technical Reports Server (NTRS)

    Holland, Frederic A., Jr.

    2004-01-01

    Modern engineering design practices are tending more toward the treatment of design parameters as random variables as opposed to fixed, or deterministic, values. The probabilistic design approach attempts to account for the uncertainty in design parameters by representing them as a distribution of values rather than as a single value. The motivations for this effort include preventing excessive overdesign as well as assessing and assuring reliability, both of which are important for aerospace applications. However, the determination of the probability distribution is a fundamental problem in reliability analysis. A random variable is often defined by the parameters of the theoretical distribution function that gives the best fit to experimental data. In many cases the distribution must be assumed from very limited information or data. Often the types of information that are available or reasonably estimated are the minimum, maximum, and most likely values of the design parameter. For these situations the beta distribution model is very convenient because the parameters that define the distribution can be easily determined from these three pieces of information. Widely used in the field of operations research, the beta model is very flexible and is also useful for estimating the mean and standard deviation of a random variable given only the aforementioned three values. However, an assumption is required to determine the four parameters of the beta distribution from only these three pieces of information (some of the more common distributions, like the normal, lognormal, gamma, and Weibull distributions, have two or three parameters). The conventional method assumes that the standard deviation is a certain fraction of the range. The beta parameters are then determined by solving a set of equations simultaneously. A new method developed in-house at the NASA Glenn Research Center assumes a value for one of the beta shape parameters based on an analogy with the normal

  17. Specificity of reliable change models and review of the within-subjects standard deviation as an error term.

    PubMed

    Hinton-Bayre, Anton D

    2011-02-01

    There is an ongoing debate over the preferred method(s) for determining the reliable change (RC) in individual scores over time. In the present paper, specificity comparisons of several classic and contemporary RC models were made using a real data set. This included a more detailed review of a new RC model recently proposed in this journal, that used the within-subjects standard deviation (WSD) as the error term. It was suggested that the RC(WSD) was more sensitive to change and theoretically superior. The current paper demonstrated that even in the presence of mean practice effects, false-positive rates were comparable across models when reliability was good and initial and retest variances were equivalent. However, when variances differed, discrepancies in classification across models became evident. Notably, the RC using the WSD provided unacceptably high false-positive rates in this setting. It was considered that the WSD was never intended for measuring change in this manner. The WSD actually combines systematic and error variance. The systematic variance comes from measurable between-treatment differences, commonly referred to as practice effect. It was further demonstrated that removal of the systematic variance and appropriate modification of the residual error term for the purpose of testing individual change yielded an error term already published and criticized in the literature. A consensus on the RC approach is needed. To that end, further comparison of models under varied conditions is encouraged.

  18. 9 CFR 318.308 - Deviations in processing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Deviations in processing (or process deviations) must be handled according to: (1)(i) A HACCP plan for canned..., containers in the retort intake valve and in transfer valves between retort shells at the time of a jam or... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Deviations in processing. 318.308...

  19. 48 CFR 2901.404 - Class deviations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... through the Director, DAMS. (b) Requests for deviations under paragraph (a) of this section must be... contracting actions which will be affected. (c) For a FAR class deviation the Director, DAMS will consult with... Director, DAMS as required in FAR 1.404. ...

  20. 48 CFR 2901.404 - Class deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... through the Director, DAMS. (b) Requests for deviations under paragraph (a) of this section must be... contracting actions which will be affected. (c) For a FAR class deviation the Director, DAMS will consult with... Director, DAMS as required in FAR 1.404. ...

  1. An Application of Extreme Value Theory to Learning Analytics: Predicting Collaboration Outcome from Eye-Tracking Data

    ERIC Educational Resources Information Center

    Sharma, Kshitij; Chavez-Demoulin, Valérie; Dillenbourg, Pierre

    2017-01-01

    The statistics used in education research are based on central trends such as the mean or standard deviation, discarding outliers. This paper adopts another viewpoint that has emerged in statistics, called extreme value theory (EVT). EVT claims that the bulk of normal distribution is comprised mainly of uninteresting variations while the most…

  2. Caution regarding the choice of standard deviations to guide sample size calculations in clinical trials.

    PubMed

    Chen, Henian; Zhang, Nanhua; Lu, Xiaosun; Chen, Sophie

    2013-08-01

    The method used to determine choice of standard deviation (SD) is inadequately reported in clinical trials. Underestimations of the population SD may result in underpowered clinical trials. This study demonstrates how using the wrong method to determine population SD can lead to inaccurate sample sizes and underpowered studies, and offers recommendations to maximize the likelihood of achieving adequate statistical power. We review the practice of reporting sample size and its effect on the power of trials published in major journals. Simulated clinical trials were used to compare the effects of different methods of determining SD on power and sample size calculations. Prior to 1996, sample size calculations were reported in just 1%-42% of clinical trials. This proportion increased from 38% to 54% after the initial Consolidated Standards of Reporting Trials (CONSORT) was published in 1996, and from 64% to 95% after the revised CONSORT was published in 2001. Nevertheless, underpowered clinical trials are still common. Our simulated data showed that all minimal and 25th-percentile SDs fell below 44 (the population SD), regardless of sample size (from 5 to 50). For sample sizes 5 and 50, the minimum sample SDs underestimated the population SD by 90.7% and 29.3%, respectively. If only one sample was available, there was less than 50% chance that the actual power equaled or exceeded the planned power of 80% for detecting a median effect size (Cohen's d = 0.5) when using the sample SD to calculate the sample size. The proportions of studies with actual power of at least 80% were about 95%, 90%, 85%, and 80% when we used the larger SD, 80% upper confidence limit (UCL) of SD, 70% UCL of SD, and 60% UCL of SD to calculate the sample size, respectively. When more than one sample was available, the weighted average SD resulted in about 50% of trials being underpowered; the proportion of trials with power of 80% increased from 90% to 100% when the 75th percentile and the

  3. Global value chains and agrifood standards: Challenges and possibilities for smallholders in developing countries

    PubMed Central

    Lee, Joonkoo; Gereffi, Gary; Beauvais, Janet

    2012-01-01

    The rise of private food standards has brought forth an ongoing debate about whether they work as a barrier for smallholders and hinder poverty reduction in developing countries. This paper uses a global value chain approach to explain the relationship between value chain structure and agrifood safety and quality standards and to discuss the challenges and possibilities this entails for the upgrading of smallholders. It maps four potential value chain scenarios depending on the degree of concentration in the markets for agrifood supply (farmers and manufacturers) and demand (supermarkets and other food retailers) and discusses the impact of lead firms and key intermediaries on smallholders in different chain situations. Each scenario is illustrated with case examples. Theoretical and policy issues are discussed, along with proposals for future research in terms of industry structure, private governance, and sustainable value chains. PMID:21149723

  4. 48 CFR 1401.403 - Individual deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Individual deviations. 1401.403 Section 1401.403 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR GENERAL DEPARTMENT OF THE INTERIOR ACQUISITION REGULATION SYSTEM Deviations from the FAR and DIAR 1401.403 Individual...

  5. MUSiC—An Automated Scan for Deviations between Data and Monte Carlo Simulation

    NASA Astrophysics Data System (ADS)

    Meyer, Arnd

    2010-02-01

    A model independent analysis approach is presented, systematically scanning the data for deviations from the standard model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of event generators. The approach is sensitive to a variety of models of new physics, including those not yet thought of.

  6. MUSiC - An Automated Scan for Deviations between Data and Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Arnd

    2010-02-10

    A model independent analysis approach is presented, systematically scanning the data for deviations from the standard model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of event generators. The approach is sensitive to a variety of models of new physics, including those not yet thought of.

  7. The Calibration of the Corneal Light Reflex to Estimate the Degree of an Angle of Deviation.

    PubMed

    Tengtrisorn, Supaporn; Tangkijwongpaisarn, Sitthi; Burachokvivat, Somporn

    2015-12-01

    To measure the conversion factor for the size of an angle of deviation from the clinical photographs of the corneal light reflex. In this cross-sectional study, 19 normal subjects with 20/20 visual acuity were photographed with a digital camera while staring at targets placed five prism diopters (PD) apart from one another on a screen. The subjects were tested at a distance of 1 meter (m) and 4 m from a screen. Measurement of the corneal light reflex displacement for each fixed target was obtained from the photographs. The calibration of the corneal light reflex displacement in millimeters (mm) against the angle of deviation in PD was then analyzed with repeated measure linear regression analysis. At 1 m, the values of 0.047 mm/PD and 0.058 mm/PD were obtained as the conversion factor from reflex displacement to deviated angle for the nasal side and temporal side respectively. At 4 m, the values were 0.050 mm/PD and 0.064 mm/PD for the nasal side and the temporal side respectively. There were significant differences between the values obtained at the different distances, regardless of nasal or temporal side. Conversion factors were presented for estimating the strabismic angle at different distances and gazes. For clinical practice, the use of photographs to estimate the strabismic angle should use different values for different distances and strabismic types.

  8. Dispersion in Rectangular Networks: Effective Diffusivity and Large-Deviation Rate Function

    NASA Astrophysics Data System (ADS)

    Tzella, Alexandra; Vanneste, Jacques

    2016-09-01

    The dispersion of a diffusive scalar in a fluid flowing through a network has many applications including to biological flows, porous media, water supply, and urban pollution. Motivated by this, we develop a large-deviation theory that predicts the evolution of the concentration of a scalar released in a rectangular network in the limit of large time t ≫1 . This theory provides an approximation for the concentration that remains valid for large distances from the center of mass, specifically for distances up to O (t ) and thus much beyond the O (t1 /2) range where a standard Gaussian approximation holds. A byproduct of the approach is a closed-form expression for the effective diffusivity tensor that governs this Gaussian approximation. Monte Carlo simulations of Brownian particles confirm the large-deviation results and demonstrate their effectiveness in describing the scalar distribution when t is only moderately large.

  9. 41 CFR 115-1.110 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Deviations. 115-1.110 Section 115-1.110 Public Contracts and Property Management Federal Property Management Regulations System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.110 Deviations...

  10. Comparison of standardized uptake value-based positron emission tomography and computed tomography target volumes in esophageal cancer patients undergoing radiotherapy.

    PubMed

    Vali, Faisal S; Nagda, Suneel; Hall, William; Sinacore, James; Gao, Mingcheng; Lee, Steven H; Hong, Robert; Shoup, Margaret; Emami, Bahman

    2010-11-15

    To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV ≥2, ≥2.5, ≥3, ≥3.5 (SUV(n)); ≥40%, ≥45%, and ≥50% of the maximum (SUV(n%)); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV(Lnσ)). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV(2.5) (0.47 ± 0.03) and SUV(L4σ) (0.48 ± 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV(2.5) (1.18 ± 0.36) and SUV(L4σ) (1.09 ± 0.15). The mean value of the SUVs calculated using the SUV(L4σ) approach was 2.4. Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. 41 CFR 101-1.110 - Deviation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Deviation. 101-1.110 Section 101-1.110 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.110 Deviation...

  12. 41 CFR 105-1.110 - Deviation.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Deviation. 105-1.110 Section 105-1.110 Public Contracts and Property Management Federal Property Management Regulations System (Continued) GENERAL SERVICES ADMINISTRATION 1-INTRODUCTION 1.1-Regulations System § 105-1.110 Deviation. (a...

  13. Telemetry Standards, RCC Standard 106-17, Annex A.1, Pulse Amplitude Modulation Standards

    DTIC Science & Technology

    2017-07-01

    conform to either Figure Error! No text of specified style in document.-1 or Figure Error! No text of specified style in document.-2. Figure Error...No text of specified style in document.-1. 50 percent duty cycle PAM with amplitude synchronization A 20-25 percent deviation reserved for pulse...synchronization is recommended. Telemetry Standards, RCC Standard 106-17 Annex A.1, July 2017 A.1.2 Figure Error! No text of specified style

  14. Acute myocardial infarction with changing axis deviation.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2011-07-01

    Changing axis deviation has been rarely reported also during atrial fibrillation or atrial flutter. Changing axis deviation has been rarely reported also during acute myocardial infarction associated with atrial fibrillation. Isolated left posterior hemiblock is a very rare finding but the evidence of transient right axis deviation with a left posterior hemiblock pattern has been reported during acute anterior myocardial infarction as related with significant right coronary artery obstruction and collateral circulation between the left coronary system and the posterior descending artery. Left anterior hemiblock development during acute inferior myocardial infarction can be an indicator of left anterior descending coronary artery lesions, multivessel coronary artery disease, and impaired left ventricular systolic function. We present a case of changing axis deviation in a 62-year-old Italian man with acute myocardial infarction. Also this case focuses attention on changing axis deviation during acute myocardial infarction. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  15. Perceptions of midline deviations among different facial types.

    PubMed

    Williams, Ryan P; Rinchuse, Daniel J; Zullo, Thomas G

    2014-02-01

    The correction of a deviated midline can involve complicated mechanics and a protracted treatment. The threshold below which midline deviations are considered acceptable might depend on multiple factors. The objective of this study was to evaluate the effect of facial type on laypersons' perceptions of various degrees of midline deviation. Smiling photographs of male and female subjects were altered to create 3 facial type variations (euryprosopic, mesoprosopic, and leptoprosopic) and deviations in the midline ranging from 0.0 to 4.0 mm. Evaluators rated the overall attractiveness and acceptability of each photograph. Data were collected from 160 raters. The overall threshold for the acceptability of a midline deviation was 2.92 ± 1.10 mm, with the threshold for the male subject significantly lower than that for the female subject. The euryprosopic facial type showed no decrease in mean attractiveness until the deviations were 2 mm or more. All other facial types were rated as decreasingly attractive from 1 mm onward. Among all facial types, the attractiveness of the male subject was only affected at deviations of 2 mm or greater; for the female subject, the attractiveness scores were significantly decreased at 1 mm. The mesoprosopic facial type was most attractive for the male subject but was the least attractive for the female subject. Facial type and sex may affect the thresholds at which a midline deviation is detected and above which a midline deviation is considered unacceptable. Both the euryprosopic facial type and male sex were associated with higher levels of attractiveness at relatively small levels of deviations. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  16. Application of Allan Deviation to Assessing Uncertainties of Continuous-measurement Instruments, and Optimizing Calibration Schemes

    NASA Astrophysics Data System (ADS)

    Jacobson, Gloria; Rella, Chris; Farinas, Alejandro

    2014-05-01

    Technological advancement of instrumentation in atmospheric and other geoscience disciplines over the past decade has lead to a shift from discrete sample analysis to continuous, in-situ monitoring. Standard error analysis used for discrete measurements is not sufficient to assess and compare the error contribution of noise and drift from continuous-measurement instruments, and a different statistical analysis approach should be applied. The Allan standard deviation analysis technique developed for atomic clock stability assessment by David W. Allan [1] can be effectively and gainfully applied to continuous measurement instruments. As an example, P. Werle et al has applied these techniques to look at signal averaging for atmospheric monitoring by Tunable Diode-Laser Absorption Spectroscopy (TDLAS) [2]. This presentation will build on, and translate prior foundational publications to provide contextual definitions and guidelines for the practical application of this analysis technique to continuous scientific measurements. The specific example of a Picarro G2401 Cavity Ringdown Spectroscopy (CRDS) analyzer used for continuous, atmospheric monitoring of CO2, CH4 and CO will be used to define the basics features the Allan deviation, assess factors affecting the analysis, and explore the time-series to Allan deviation plot translation for different types of instrument noise (white noise, linear drift, and interpolated data). In addition, the useful application of using an Allan deviation to optimize and predict the performance of different calibration schemes will be presented. Even though this presentation will use the specific example of the Picarro G2401 CRDS Analyzer for atmospheric monitoring, the objective is to present the information such that it can be successfully applied to other instrument sets and disciplines. [1] D.W. Allan, "Statistics of Atomic Frequency Standards," Proc, IEEE, vol. 54, pp 221-230, Feb 1966 [2] P. Werle, R. Miicke, F. Slemr, "The Limits

  17. Price adjustment for traditional Chinese medicine procedures: Based on a standardized value parity model.

    PubMed

    Wang, Haiyin; Jin, Chunlin; Jiang, Qingwu

    2017-11-20

    Traditional Chinese medicine (TCM) is an important part of China's medical system. Due to the prolonged low price of TCM procedures and the lack of an effective mechanism for dynamic price adjustment, the development of TCM has markedly lagged behind Western medicine. The World Health Organization (WHO) has emphasized the need to enhance the development of alternative and traditional medicine when creating national health care systems. The establishment of scientific and appropriate mechanisms to adjust the price of medical procedures in TCM is crucial to promoting the development of TCM. This study has examined incorporating value indicators and data on basic manpower expended, time spent, technical difficulty, and the degree of risk in the latest standards for the price of medical procedures in China, and this study also offers a price adjustment model with the relative price ratio as a key index. This study examined 144 TCM procedures and found that prices of TCM procedures were mainly based on the value of medical care provided; on average, medical care provided accounted for 89% of the price. Current price levels were generally low and the current price accounted for 56% of the standardized value of a procedure, on average. Current price levels accounted for a markedly lower standardized value of acupuncture, moxibustion, special treatment with TCM, and comprehensive TCM procedures. This study selected a total of 79 procedures and adjusted them by priority. The relationship between the price of TCM procedures and the suggested price was significantly optimized (p < 0.01). This study suggests that adjustment of the price of medical procedures based on a standardized value parity model is a scientific and suitable method of price adjustment that can serve as a reference for other provinces and municipalities in China and other countries and regions that mainly have fee-for-service (FFS) medical care.

  18. The standard deviation of extracellular water/intracellular water is associated with all-cause mortality and technique failure in peritoneal dialysis patients.

    PubMed

    Tian, Jun-Ping; Wang, Hong; Du, Feng-He; Wang, Tao

    2016-09-01

    The mortality rate of peritoneal dialysis (PD) patients is still high, and the predicting factors for PD patient mortality remain to be determined. This study aimed to explore the relationship between the standard deviation (SD) of extracellular water/intracellular water (E/I) and all-cause mortality and technique failure in continuous ambulatory PD (CAPD) patients. All 152 patients came from the PD Center between January 1st 2006 and December 31st 2007. Clinical data and at least five-visit E/I ratio defined by bioelectrical impedance analysis were collected. The patients were followed up till December 31st 2010. The primary outcomes were death from any cause and technique failure. Kaplan-Meier analysis and Cox proportional hazards models were used to identify risk factors for mortality and technique failure in CAPD patients. All patients were followed up for 59.6 ± 23.0 months. The patients were divided into two groups according to their SD of E/I values: lower SD of E/I group (≤0.126) and higher SD of E/I group (>0.126). The patients with higher SD of E/I showed a higher all-cause mortality (log-rank χ (2) = 10.719, P = 0.001) and technique failure (log-rank χ (2) = 9.724, P = 0.002) than those with lower SD of E/I. Cox regression analysis found that SD of E/I independently predicted all-cause mortality (HR  3.551, 95 % CI 1.442-8.746, P = 0.006) and technique failure (HR  2.487, 95 % CI 1.093-5.659, P = 0.030) in CAPD patients after adjustment for confounders except when sensitive C-reactive protein was added into the model. The SD of E/I was a strong independent predictor of all-cause mortality and technique failure in CAPD patients.

  19. Correlations between ankle-foot impairments and dropped foot gait deviations among stroke survivors.

    PubMed

    Chisholm, Amanda E; Perry, Stephen D; McIlroy, William E

    2013-01-01

    The purpose of this paper is to 1) evaluate the relationship between ankle kinematics during gait and standardized measures of ankle impairments among sub-acute stroke survivors, and 2) compare the degree of stroke-related ankle impairment between individuals with and without dropped foot gait deviations. Fifty-five independently ambulating stroke survivors participated in this study. Dropped foot was defined as decreased peak dorsiflexion during the swing phase and reduced ankle joint motion in stance. Standardized outcome measures included the Chedoke-McMaster Stroke Assessment (motor impairment), Modified Ashworth Scale (spasticity), Medical Research Council (muscle strength), passive and active range of motion, and isometric muscle force. Foot impairment was not related to peak dorsiflexion during swing (r=-0.17, P=0.247) and joint motion during stance (r=0.05, P=0.735). Active (r=0.45, P<0.001) and passive (r=0.48, P<0.001) range of motion was associated with stance phase joint motion. Peak dorsiflexion during swing was related to isometric dorsiflexor muscle force (r=-0.32, P=0.039). Individuals with dropped foot demonstrated greater motor impairment, plantarflexor spasticity and ankle muscle weakness compared to those without dropped foot. Our investigation suggests that ankle-foot impairments are related to ankle deviations during gait, as indicated by greater impairment among individuals with dropped foot. These findings contribute to a better understanding of gait-specific ankle deviations, and may lead to the development of a more effective clinical assessment of dropped foot impairment. © 2013.

  20. Back in the saddle: large-deviation statistics of the cosmic log-density field

    NASA Astrophysics Data System (ADS)

    Uhlemann, C.; Codis, S.; Pichon, C.; Bernardeau, F.; Reimberg, P.

    2016-08-01

    We present a first principle approach to obtain analytical predictions for spherically averaged cosmic densities in the mildly non-linear regime that go well beyond what is usually achieved by standard perturbation theory. A large deviation principle allows us to compute the leading order cumulants of average densities in concentric cells. In this symmetry, the spherical collapse model leads to cumulant generating functions that are robust for finite variances and free of critical points when logarithmic density transformations are implemented. They yield in turn accurate density probability distribution functions (PDFs) from a straightforward saddle-point approximation valid for all density values. Based on this easy-to-implement modification, explicit analytic formulas for the evaluation of the one- and two-cell PDF are provided. The theoretical predictions obtained for the PDFs are accurate to a few per cent compared to the numerical integration, regardless of the density under consideration and in excellent agreement with N-body simulations for a wide range of densities. This formalism should prove valuable for accurately probing the quasi-linear scales of low-redshift surveys for arbitrary primordial power spectra.

  1. Combining Mean and Standard Deviation of Hounsfield Unit Measurements from Preoperative CT Allows More Accurate Prediction of Urinary Stone Composition Than Mean Hounsfield Units Alone.

    PubMed

    Tailly, Thomas; Larish, Yaniv; Nadeau, Brandon; Violette, Philippe; Glickman, Leonard; Olvera-Posada, Daniel; Alenezi, Husain; Amann, Justin; Denstedt, John; Razvi, Hassan

    2016-04-01

    The mineral composition of a urinary stone may influence its surgical and medical treatment. Previous attempts at identifying stone composition based on mean Hounsfield Units (HUm) have had varied success. We aimed to evaluate the additional use of standard deviation of HU (HUsd) to more accurately predict stone composition. We identified patients from two centers who had undergone urinary stone treatment between 2006 and 2013 and had mineral stone analysis and a computed tomography (CT) available. HUm and HUsd of the stones were compared with ANOVA. Receiver operative characteristic analysis with area under the curve (AUC), Youden index, and likelihood ratio calculations were performed. Data were available for 466 patients. The major components were calcium oxalate monohydrate (COM), uric acid, hydroxyapatite, struvite, brushite, cystine, and CO dihydrate (COD) in 41.4%, 19.3%, 12.4%, 7.5%, 5.8%, 5.4%, and 4.7% of patients, respectively. The HUm of UA and Br was significantly lower and higher than the HUm of any other stone type, respectively. HUm and HUsd were most accurate in predicting uric acid with an AUC of 0.969 and 0.851, respectively. The combined use of HUm and HUsd resulted in increased positive predictive value and higher likelihood ratios for identifying a stone's mineral composition for all stone types but COM. To the best of our knowledge, this is the first report of CT data aiding in the prediction of brushite stone composition. Both HUm and HUsd can help predict stone composition and their combined use results in higher likelihood ratios influencing probability.

  2. Transport Coefficients from Large Deviation Functions

    NASA Astrophysics Data System (ADS)

    Gao, Chloe; Limmer, David

    2017-10-01

    We describe a method for computing transport coefficients from the direct evaluation of large deviation function. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which is a scaled cumulant generating function analogous to the free energy. A diffusion Monte Carlo algorithm is used to evaluate the large deviation functions, from which arbitrary transport coefficients are derivable. We find significant statistical improvement over traditional Green-Kubo based calculations. The systematic and statistical errors of this method are analyzed in the context of specific transport coefficient calculations, including the shear viscosity, interfacial friction coefficient, and thermal conductivity.

  3. CAN'T MISS--conquer any number task by making important statistics simple. Part 1. Types of variables, mean, median, variance, and standard deviation.

    PubMed

    Hansen, John P

    2003-01-01

    Healthcare quality improvement professionals need to understand and use inferential statistics to interpret sample data from their organizations. In quality improvement and healthcare research studies all the data from a population often are not available, so investigators take samples and make inferences about the population by using inferential statistics. This three-part series will give readers an understanding of the concepts of inferential statistics as well as the specific tools for calculating confidence intervals for samples of data. This article, Part 1, presents basic information about data including a classification system that describes the four major types of variables: continuous quantitative variable, discrete quantitative variable, ordinal categorical variable (including the binomial variable), and nominal categorical variable. A histogram is a graph that displays the frequency distribution for a continuous variable. The article also demonstrates how to calculate the mean, median, standard deviation, and variance for a continuous variable.

  4. Urinary growth hormone level and insulin-like growth factor-1 standard deviation score (IGF-SDS) can discriminate adult patients with severe growth hormone deficiency.

    PubMed

    Hirohata, Toshio; Saito, Nobuhito; Takano, Koji; Yamada, So; Son, Jae-Hyun; Yamada, Shoko M; Nakaguchi, Hiroshi; Hoya, Katsumi; Murakami, Mineko; Mizutani, Akiko; Okinaga, Hiroko; Matsuno, Akira

    2013-01-01

    Adult growth hormone (GH) deficiency (AGHD) in Japan is diagnosed based on peak GH concentrations during GH provocative tests such as GHRP-2 stimulation test. In this study, we aimed to evaluate the ability of serum insulin-like growth factor-1 (sIGF-1) and urinary GH (uGH) at the time of awakening to diagnose AGHD. Fifty-nine patients with pituitary disease (32 men and 27 women; age 20-85 y (57.5 ± 15.5, mean ± SD) underwent GHRP-2 stimulation and sIGF-1 testing. Thirty-six and 23 patients were diagnosed with and without severe AGHD, respectively based on a peak GH response of <9 ng/mL to GHRP-2 stimulation. Serum IGF-1 was evaluated as a standard deviation score (IGF-1 SDS) based on age and sex. We determined whether uGH levels in urine samples from 42 of the 59 patients at awakening were above or below the sensitivity limit. We evaluated IGF-1 SDS and uGH levels in a control group of 15 healthy volunteers. Values for IGF-1 SDS were significantly lower in patients with, than without (-2.07 ± 1.77 vs.-0.03 ± 0.92, mean ± SD; p < 0.001) AGHD whereas the range of IGF-1 SDS substantially overlapped at > -1.4. IGF-1 SDS discriminated AGHD more effectively in patients aged ≤60 years. The χ2 test revealed a statistical relationship between uGH and AGHD (test statistic: 7.0104 ≥ χ2 (1; 0.01) = 6.6349). When IGF-1 SDS is < -1.4 or uGH is below the sensitivity limit, AGHD can be detected with high sensitivity.

  5. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true What is a deviation? 63.1965 Section 63.1965 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Compliance Requirements § 63.1965 What is a deviation? A deviation is defined in § 63.1990. For the purposes...

  6. Reliability and Minimum Detectable Change of the Gait Deviation Index (GDI) in post-stroke patients.

    PubMed

    Correa, Katren Pedroso; Devetak, Gisele Francini; Martello, Suzane Ketlyn; de Almeida, Juliana Carla; Pauleto, Ana Carolina; Manffra, Elisangela Ferretti

    2017-03-01

    The Gait Deviation Index (GDI) is a summary measure that provides a global picture of gait kinematic data. Since the ability to walk is critical for post-stroke patients, the aim of this study was to determine the reliability and Minimum Detectable Change (MDC) of the GDI in this patient population. Twenty post-stroke patients (11 males, 9 females; mean age, 55.2±9.9years) participated in this study. Patients presented with either right- (n=14) or left-sided (n=6) hemiparesis. Kinematic gait data were collected in two sessions (test and retest) that were 2 to 7days apart. GDI values in the first and second sessions were, respectively, 59.0±8.1 and 60.2±9.4 for the paretic limb and 53.3±8.3 and 53.4±8.3 for the non-paretic limb. The reliability in each session was determined by the intra-class correlation coefficient (ICC) of three strides and, in the test session, their values were 0.91 and 0.97 for the paretic and non-paretic limbs, respectively. Between-session reliability and MDC were determined using the average GDI of three strides from each session. For the paretic limb, between-session ICC, standard error of measurement (SEM), and MDC were 0.84, 3.4 and 9.4, respectively. Non paretic lower limb exhibited between-session ICC, standard error of measurement (SEM), and MDC of 0.89, 2.7 and 7.5, respectively. These MDC values indicate that very large changes in GDI are required to identify gait improvement. Therefore, the clinical usefulness of GDI with stroke patients is questionable. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Total focusing method (TFM) robustness to material deviations

    NASA Astrophysics Data System (ADS)

    Painchaud-April, Guillaume; Badeau, Nicolas; Lepage, Benoit

    2018-04-01

    The total focusing method (TFM) is becoming an accepted nondestructive evaluation method for industrial inspection. What was a topic of discussion in the applied research community just a few years ago is now being deployed in critical industrial applications, such as inspecting welds in pipelines. However, the method's sensitivity to unexpected parametric changes (material and geometric) has not been rigorously assessed. In this article, we investigate the robustness of TFM in relation to unavoidable deviations from modeled nominal inspection component characteristics, such as sound velocities and uncertainties about the parts' internal and external diameters. We also review TFM's impact on the standard inspection modes often encountered in industrial inspections, and we present a theoretical model supported by empirical observations to illustrate the discussion.

  8. Reference values for airway resistance in newborns, infants and preschoolers from a Latin American population.

    PubMed

    Gochicoa, Laura G; Thomé-Ortiz, Laura P; Furuya, María E Y; Canto, Raquel; Ruiz-García, Martha E; Zúñiga-Vázquez, Guillermo; Martínez-Ramírez, Filiberto; Vargas, Mario H

    2012-05-01

    Several studies have determined reference values for airway resistance measured by the interrupter technique (Rint) in paediatric populations, but only one has been done on Latin American children, and no studies have been performed on Mexican children. Moreover, these previous studies mostly included children aged 3 years and older; therefore, information regarding Rint reference values for newborns and infants is scarce. Rint measurements were performed on preschool children attending eight kindergartens (Group 1) and also on sedated newborns, infants and preschool children admitted to a tertiary-level paediatric hospital due to non-cardiopulmonary disorders (Group 2). In both groups, Rint values were inversely associated with age, weight and height, but the strongest association was with height. The linear regression equation for Group 1 (n = 209, height 86-129 cm) was Rint = 2.153 - 0.012 × height (cm) (standard deviation of residuals 0.181 kPa/L/s). The linear regression equation for Group 2 (n = 55, height 52-113 cm) was Rint = 4.575 - 0.035 × height (cm) (standard deviation of residuals 0.567 kPa/L/s). Girls tended to have slightly higher Rint values than boys, a difference that diminished with increasing height. In this study, Rint reference values applicable to Mexican children were determined, and these values are probably also applicable to other paediatric populations with similar Spanish-Amerindian ancestries. There was an inverse relationship between Rint and height, with relatively large between-subject variability. © 2012 The Authors. Respirology © 2012 Asian Pacific Society of Respirology.

  9. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true What is a deviation? 63.1965 Section 63.1965 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Requirements § 63.1965 What is a deviation? A deviation is defined in § 63.1990. For the purposes of the...

  10. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 12 2011-07-01 2009-07-01 true What is a deviation? 63.1965 Section 63.1965 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Requirements § 63.1965 What is a deviation? A deviation is defined in § 63.1990. For the purposes of the...

  11. 33 CFR 155.5012 - Deviation from response plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Deviation from response plan. 155... Response Plans § 155.5012 Deviation from response plan. The owner or operator of a nontank vessel required to have a vessel response plan (VRP) under this subpart may not deviate from the approved VRP unless...

  12. Changing axis deviation during acute myocardial infarction.

    PubMed

    Patanè, Salvatore; Marte, Filippo

    2010-07-09

    Changing axis deviation has been reported during acute myocardial infarction also associated with atrial fibrillation. Isolated left posterior hemiblock is a very rare finding but the evidence of transient right axis deviation with a left posterior hemiblock pattern has been reported during acute anterior myocardial infarction as related with significant right coronary artery obstruction and collateral circulation between the left coronary system and the posterior descending artery. We present a case of changing axis deviation in a 70-year-old Italian man with acute myocardial infarction. Copyright (c) 2008 Elsevier Ireland Ltd. All rights reserved.

  13. Standardizing Foot-Type Classification Using Arch Index Values

    PubMed Central

    Weil, Rich; de Boer, Emily

    2012-01-01

    ABSTRACT Purpose: The lack of a reliable classification standard for foot type makes drawing conclusions from existing research and clinical decisions difficult, since different foot types may move and respond to treatment differently. The purpose of this study was to determine interrater agreement for foot-type classification based on photo-box-derived arch index values. Method: For this correlational study with two raters, a sample of 11 healthy volunteers with normal to obese body mass indices was recruited from both a community weight-loss programme and a programme in physical therapy. Arch index was calculated using AutoCAD software from footprint photographs obtained via mirrored photo-box. Classification as high-arched, normal, or low-arched foot type was based on arch index values. Reliability of the arch index was determined with intra-class correlations; agreement on foot-type classification was determined using quadratic weighted kappa (κw). Results: Average arch index was 0.215 for one tester and 0.219 for the second tester, with an overall range of 0.017 to 0.370. Both testers classified 6 feet as low-arched, 9 feet as normal, and 7 feet as high-arched. Interrater reliability for the arch index was ICC=0.90; interrater agreement for foot-type classification was κw=0.923. Conclusions: Classification of foot type based on arch index values derived from plantar footprint photographs obtained via mirrored photo-box showed excellent reliability in people with varying BMI. Foot-type classification may help clinicians and researchers subdivide sample populations to better differentiate mobility, gait, or treatment effects among foot types. PMID:23729964

  14. Regional ADC values of the normal brain: differences due to age, gender, and laterality.

    PubMed

    Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference.

  15. How do we assign punishment? The impact of minimal and maximal standards on the evaluation of deviants.

    PubMed

    Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven

    2010-09-01

    To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.

  16. a Web-Based Framework for Visualizing Industrial Spatiotemporal Distribution Using Standard Deviational Ellipse and Shifting Routes of Gravity Centers

    NASA Astrophysics Data System (ADS)

    Song, Y.; Gui, Z.; Wu, H.; Wei, Y.

    2017-09-01

    Analysing spatiotemporal distribution patterns and its dynamics of different industries can help us learn the macro-level developing trends of those industries, and in turn provides references for industrial spatial planning. However, the analysis process is challenging task which requires an easy-to-understand information presentation mechanism and a powerful computational technology to support the visual analytics of big data on the fly. Due to this reason, this research proposes a web-based framework to enable such a visual analytics requirement. The framework uses standard deviational ellipse (SDE) and shifting route of gravity centers to show the spatial distribution and yearly developing trends of different enterprise types according to their industry categories. The calculation of gravity centers and ellipses is paralleled using Apache Spark to accelerate the processing. In the experiments, we use the enterprise registration dataset in Mainland China from year 1960 to 2015 that contains fine-grain location information (i.e., coordinates of each individual enterprise) to demonstrate the feasibility of this framework. The experiment result shows that the developed visual analytics method is helpful to understand the multi-level patterns and developing trends of different industries in China. Moreover, the proposed framework can be used to analyse any nature and social spatiotemporal point process with large data volume, such as crime and disease.

  17. Design of ultraviolet wavelength and standard solution concentrations in relative response factors for simultaneous determination of multi-components with single reference standard in herbal medicines.

    PubMed

    Yang, Ting-Wen; Zhao, Chao; Fan, Yong; Qi, Lian-Wen; Li, Ping

    2015-10-10

    Single standard to determine multi-components (SSDMC) is a practical pattern for quality evaluation of herbal medicines (HMs). However, it remains challenging because of potential inconsistency of relative response factors (RRF) on different instruments. In this work, the effects of two key roles, i.e., ultraviolet (UV) wavelength and standard solution concentrations, on reproducibility of RRF were investigated. The effect of UV wavelength on reproducibility of RRF was studied by plotting the relationship of the peak area ratios (internal standard vs analyte) to wavelengths. The preferable wavelength should be set at the flat parts of the curve. Optimized 300 nm produced a 0.38% RSD for emodin/emodin-8-O-β-D-glucopyranoside on five instruments, much lower than 2.80% obtained from the maximum wavelength at 290 nm. Next, the effects of standard solution concentrations of emodin on its response factor (RF) were investigated. For one single point method, low concentration less than 49 b/k resulted in significant variations in RF. For emodin, when the concentration is higher than 7.00 μg mL(-1), a low standard deviation (SD) value at 0.13 was obtained, while lower than 7.00 μg mL(-1), a high SD at 3.71 was obtained. The developed SSDMC method was then applied to determination of target components in 10 Polygonum cuspidatum samples and showed comparable accuracy to conventional calibration methods with deviation less than 1%. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Mortality and morbidity risks vary with birth weight standard deviation score in growth restricted extremely preterm infants.

    PubMed

    Yamakawa, Takuji; Itabashi, Kazuo; Kusuda, Satoshi

    2016-01-01

    To assess whether the mortality and morbidity risks vary with birth weight standard deviation score (BWSDS) in growth restricted extremely preterm infants. This was a multicenter retrospective cohort study using the database of the Neonatal Research Network of Japan and including 9149 infants born between 2003 and 2010 at <28 weeks gestation. According to the BWSDSs, the infants were classified as: <-2.0, -2.0 to -1.5, -1.5 to -1.0, -1.0 to -0.5, and ≥-0.5. Infants with BWSDS≥-0.5 were defined as non-growth restricted group. After adjusting for covariates, the risks of mortality and some morbidities were different among the BWSDS groups. Compared with non-growth restricted group, the adjusted odds ratio (aOR) for mortality [aOR, 1.69; 95% confidence interval (CI), 1.35-2.12] and chronic lung disease (CLD) (aOR, 1.28; 95% CI, 1.07-1.54) were higher among the infants with BWSDS -1.5 to <-1.0. The aOR for severe retinopathy of prematurity (ROP) (aOR, 1.36; 95% CI, 1.09-1.71) and sepsis (aOR, 1.72; 95% CI, 1.32-2.24) were higher among the infants with BWSDS -2.0 to <-1.5. The aOR for necrotizing enterocolitis (NEC) (aOR, 2.41; 95% CI, 1.64-3.55) was increased at a BWSDS<-2.0. Being growth restricted extremely preterm infants confer additional risks for mortality and morbidities such as CLD, ROP, sepsis and NEC, and these risks may vary with BWSDS. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Are temporomandibular disorders associated with habitual sleeping body posture or nasal septal deviation?

    PubMed

    Yalçınkaya, Esin; Cingi, Cemal; Bayar Muluk, Nuray; Ulusoy, Seçkin; Hanci, Deniz

    2016-01-01

    Numerous factors can be considered for the etiology of temporomandibular disorders (TMD). The aim of the present study was to investigate whether the presence of both nasal septal deviation (NSD) and habitual prone sleeping posture (HPSP) predisposes TMD. We evaluated 200 subjects in 4 groups. Group I (NSD-, HPSP-/control group), Group II (NSD+, HPSP-), Group III (NSD-, HPSP+), Group IV (NSD+, HPSP+). All patients were examined according to the research diagnostic criteria to determine the presence of TMD. Group IV had the highest value for TMD incidence (44 %). Thus, we found that the presence of both NSD and HPSP parameters increased TMD incidence in Group IV compared to the control group (p = 0.000). Additionally, Group IV showed significantly higher values than Group II (p = 0.012) and Group III (p = 0.039). For Group III (NSD-, HPSP+), TMD was determined higher compared to the control group (p = 0.009). A statistically higher value of presence of TMD was determined in Group II (NSD+, HPSP-) than control group (p = 0.029). The incidence of TMD was significantly higher in women than men (p = 0.020). We concluded that one having an unilateral obstructive nasal septal deviation in addition to a habit of sleeping in prone position must be alert for potential TMD.

  20. 49 CFR 192.913 - When may an operator deviate its program from certain requirements of this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Transmission Pipeline Integrity Management § 192.913 When may an operator deviate its program...

  1. Use of Fat Mass and Fat Free Mass Standard Deviation Scores Obtained Using Simple Measurement Methods in Healthy Children and Patients: Comparison with the Reference 4-Component Model

    PubMed Central

    Atherton, Rachel R.; Williams, Jane E.; Wells, Jonathan C. K.; Fewtrell, Mary S.

    2013-01-01

    Background Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. Objectives (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. Design FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height2/Z)) in 927 subjects aged 3.8–22.0 y (211 healthy, 716 patients). Results DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (±0.62); FFM SDS −0.04 (±0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤−2 or ≥2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. Conclusions DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome. PMID:23690932

  2. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    PubMed

    Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S

    2013-01-01

    Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  3. USL/DBMS NASA/PC R and D project C programming standards

    NASA Technical Reports Server (NTRS)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.

  4. MUSiC - A Generic Search for Deviations from Monte Carlo Predictions in CMS

    NASA Astrophysics Data System (ADS)

    Hof, Carsten

    2009-05-01

    We present a model independent analysis approach, systematically scanning the data for deviations from the Standard Model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of the event generators. Furthermore, due to the minimal theoretical bias this approach is sensitive to a variety of models of new physics, including those not yet thought of. Events are classified into event classes according to their particle content (muons, electrons, photons, jets and missing transverse energy). A broad scan of various distributions is performed, identifying significant deviations from the Monte Carlo simulation. We outline the importance of systematic uncertainties, which are taken into account rigorously within the algorithm. Possible detector effects and generator issues, as well as models involving supersymmetry and new heavy gauge bosons have been used as an input to the search algorithm.

  5. Temperature deviation index and elderly mortality in Japan.

    PubMed

    Lim, Youn-Hee; Reid, Colleen E; Honda, Yasushi; Kim, Ho

    2016-07-01

    Few studies have examined how the precedence of abnormal temperatures in previous neighboring years affects the population's health. In the present study, we attempted to quantify the health effects of abnormal weather patterns by creating a metric called the temperature deviation index (TDI) and estimated the effects of TDI on mortality in Japan. We used data from 47 prefectures in Japan to compute the TDI on days between May and September from 1966 to 2010. The TDI is a summed product of an indicator of absence of high temperatures in the neighboring years, and more weights were assigned to the years closest to the current year. To estimate the TDI effects on elderly mortality, we used generalized linear modeling with a Poisson distribution after adjusting for apparent temperature, barometric pressure, day of the week, and time trend. For each prefecture, we estimated the TDI effects and pooled the estimates to yield a national average for 1991-2010 in Japan. The estimated effects of TDI in middle- or high-latitude prefectures were greater than in low-latitude prefectures. The estimated national average of TDI effects was a 0.5 % (95 % confidence intervals [CI], 0.1, 1.0) increase in elderly mortality per 1-unit (around 1 standard deviation) increase in the TDI. The significant pooled estimation of TDI effects was mainly due to the TDI effects on summer days with moderate temperature (25th-49th percentile, mean temperature 22.9 °C): a 1.9 % (95 % CI, 1.1, 2.6) increase in elderly mortality per 1-unit increase in the TDI. However, TDI effects were insignificant in other temperature ranges. These findings suggest that elderly deaths increased on moderate temperature days in the summer that differed substantially from days during that time window in the neighboring years. Therefore, not only high temperature itself but also temperature deviation compared to previous years could be considered to be a risk factor for elderly mortality in the summer.

  6. Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.

    PubMed

    Bowman, Richard G; Caraway, David; Bentley, Ishmael

    2013-01-01

    Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.

  7. Implied Maximum Dose Analysis of Standard Values of 25 Pesticides Based on Major Human Exposure Pathways

    PubMed Central

    Li, Zijian; Jennings, Aaron A.

    2017-01-01

    Worldwide jurisdictions are making efforts to regulate pesticide standard values in residential soil, drinking water, air, and agricultural commodity to lower the risk of pesticide impacts on human health. Because human may exposure to pesticides from many ways, such as ingestion, inhalation, and dermal contact, it is important to examine pesticide standards by considering all major exposure pathways. Analysis of implied maximum dose limits for commonly historical and current used pesticides was adopted in this study to examine whether worldwide pesticide standard values are enough to prevent human health impact or not. Studies show that only U.S. has regulated pesticides standard in the air. Only 4% of the total number of implied maximum dose limits is based on three major exposures. For Chlorpyrifos, at least 77.5% of the total implied maximum dose limits are above the acceptable daily intake. It also shows that most jurisdictions haven't provided pesticide standards in all major exposures yet, and some of the standards are not good enough to protect human health. PMID:29546224

  8. Head-To-Head Comparison Between High- and Standard-b-Value DWI for Detecting Prostate Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Woo, Sungmin; Suh, Chong Hyun; Kim, Sang Youn; Cho, Jeong Yeon; Kim, Seung Hyup

    2018-01-01

    The purpose of this study was to perform a head-to-head comparison between high-b-value (> 1000 s/mm 2 ) and standard-b-value (800-1000 s/mm 2 ) DWI regarding diagnostic performance in the detection of prostate cancer. The MEDLINE and EMBASE databases were searched up to April 1, 2017. The analysis included diagnostic accuracy studies in which high- and standard-b-value DWI were used for prostate cancer detection with histopathologic examination as the reference standard. Methodologic quality was assessed with the revised Quality Assessment of Diagnostic Accuracy Studies tool. Sensitivity and specificity of all studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Meta-regression and multiple-subgroup analyses were performed to compare the diagnostic performances of high- and standard-b-value DWI. Eleven studies (789 patients) were included. High-b-value DWI had greater pooled sensitivity (0.80 [95% CI, 0.70-0.87]) (p = 0.03) and specificity (0.92 [95% CI, 0.87-0.95]) (p = 0.01) than standard-b-value DWI (sensitivity, 0.78 [95% CI, 0.66-0.86]); specificity, 0.87 [95% CI, 0.77-0.93] (p < 0.01). Multiple-subgroup analyses showed that specificity was consistently higher for high- than for standard-b-value DWI (p ≤ 0.05). Sensitivity was significantly higher for high- than for standard-b-value DWI only in the following subgroups: peripheral zone only, transition zone only, multiparametric protocol (DWI and T2-weighted imaging), visual assessment of DW images, and per-lesion analysis (p ≤ 0.04). In a head-to-head comparison, high-b-value DWI had significantly better sensitivity and specificity for detection of prostate cancer than did standard-b-value DWI. Multiple-subgroup analyses showed that specificity was consistently superior for high-b-value DWI.

  9. Assessment of Healthcare Worker Protocol Deviations and Self-Contamination During Personal Protective Equipment Donning and Doffing.

    PubMed

    Kwon, Jennie H; Burnham, Carey-Ann D; Reske, Kimberly A; Liang, Stephen Y; Hink, Tiffany; Wallace, Meghan A; Shupe, Angela; Seiler, Sondra; Cass, Candice; Fraser, Victoria J; Dubberke, Erik R

    2017-09-01

    OBJECTIVE To evaluate healthcare worker (HCW) risk of self-contamination when donning and doffing personal protective equipment (PPE) using fluorescence and MS2 bacteriophage. DESIGN Prospective pilot study. SETTING Tertiary-care hospital. PARTICIPANTS A total of 36 HCWs were included in this study: 18 donned/doffed contact precaution (CP) PPE and 18 donned/doffed Ebola virus disease (EVD) PPE. INTERVENTIONS HCWs donned PPE according to standard protocols. Fluorescent liquid and MS2 bacteriophage were applied to HCWs. HCWs then doffed their PPE. After doffing, HCWs were scanned for fluorescence and swabbed for MS2. MS2 detection was performed using reverse transcriptase PCR. The donning and doffing processes were videotaped, and protocol deviations were recorded. RESULTS Overall, 27% of EVD PPE HCWs and 50% of CP PPE HCWs made ≥1 protocol deviation while donning, and 100% of EVD PPE HCWs and 67% of CP PPE HCWs made ≥1 protocol deviation while doffing (P=.02). The median number of doffing protocol deviations among EVD PPE HCWs was 4, versus 1 among CP PPE HCWs. Also, 15 EVD PPE protocol deviations were committed by doffing assistants and/or trained observers. Fluorescence was detected on 8 EVD PPE HCWs (44%) and 5 CP PPE HCWs (28%), most commonly on hands. MS2 was recovered from 2 EVD PPE HCWs (11%) and 3 CP PPE HCWs (17%). CONCLUSIONS Protocol deviations were common during both EVD and CP PPE doffing, and some deviations during EVD PPE doffing were committed by the HCW doffing assistant and/or the trained observer. Self-contamination was common. PPE donning/doffing are complex and deserve additional study. Infect Control Hosp Epidemiol 2017;38:1077-1083.

  10. Precision and Deviation Comparison Between Icesat and Envisat in Typical Ice Gaining and Losing Regions of Antarctica

    NASA Astrophysics Data System (ADS)

    Du, W.; Chen, L.; Xie, H.; Hai, G.; Zhang, S.; Tong, X.

    2017-09-01

    This paper analyzes the precision and deviation of elevations acquired from Envisat and The Ice, Cloud and Land Elevation Satellite (ICESat) over typical ice gaining and losing regions, i.e. Lambert-Amery System (LAS) in east Antarctica, and Amundsen Sea Sector (ASS) in west Antarctica, during the same period from 2003 to 2008. We used GLA12 dataset of ICESat and Level 2 data of Envisat. Data preprocessing includes data filtering, projection transformation and track classification. Meanwhile, the slope correction is applied to Envisat data and saturation correction for ICESat data. Then the crossover analysis was used to obtain the crossing points of the ICESat tracks, Envisat tracks and ICESat-Envisat tracks separately. The two tracks we chose for cross-over analysis should be in the same campaign for ICESat (within 33 days) or the same cycle for Envisat (within 35 days).The standard deviation of a set of elevation residuals at time-coincident crossovers is calculated as the precision of each satellite while the mean value is calculated as the deviation of ICESat-Envisat. Generally, the ICESat laser altimeter gets a better precision than the Envisat radar altimeter. For Amundsen Sea Sector, the ICESat precision is found to vary from 8.9 cm to 17 cm and the Envisat precision varies from 0.81 m to 1.57 m. For LAS area, the ICESat precision is found to vary from 6.7 cm to 14.3 cm and the Envisat precision varies from 0.46 m to 0.81 m. Comparison result between Envisat and ICESat elevations shows a mean difference of 0.43 ±7.14 m for Amundsen Sea Sector and 0.53 ± 1.23 m over LAS.

  11. Moderate deviations-based importance sampling for stochastic recursive equations

    DOE PAGES

    Dupuis, Paul; Johnson, Dane

    2017-11-17

    Abstract Subsolutions to the Hamilton–Jacobi–Bellman equation associated with a moderate deviations approximation are used to design importance sampling changes of measure for stochastic recursive equations. Analogous to what has been done for large deviations subsolution-based importance sampling, these schemes are shown to be asymptotically optimal under the moderate deviations scaling. We present various implementations and numerical results to contrast their performance, and also discuss the circumstances under which a moderate deviation scaling might be appropriate.

  12. Moderate deviations-based importance sampling for stochastic recursive equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dupuis, Paul; Johnson, Dane

    Abstract Subsolutions to the Hamilton–Jacobi–Bellman equation associated with a moderate deviations approximation are used to design importance sampling changes of measure for stochastic recursive equations. Analogous to what has been done for large deviations subsolution-based importance sampling, these schemes are shown to be asymptotically optimal under the moderate deviations scaling. We present various implementations and numerical results to contrast their performance, and also discuss the circumstances under which a moderate deviation scaling might be appropriate.

  13. 14 CFR 142.9 - Deviations or waivers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Deviations or waivers. 142.9 Section 142.9 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND... Administrator may issue deviations or waivers from any of the requirements of this part. (b) A training center...

  14. 14 CFR 142.9 - Deviations or waivers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Deviations or waivers. 142.9 Section 142.9 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND... Administrator may issue deviations or waivers from any of the requirements of this part. (b) A training center...

  15. 14 CFR 142.9 - Deviations or waivers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Deviations or waivers. 142.9 Section 142.9 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND... Administrator may issue deviations or waivers from any of the requirements of this part. (b) A training center...

  16. 14 CFR 142.9 - Deviations or waivers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Deviations or waivers. 142.9 Section 142.9 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND... Administrator may issue deviations or waivers from any of the requirements of this part. (b) A training center...

  17. 14 CFR 142.9 - Deviations or waivers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Deviations or waivers. 142.9 Section 142.9 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SCHOOLS AND... Administrator may issue deviations or waivers from any of the requirements of this part. (b) A training center...

  18. Lower Current Large Deviations for Zero-Range Processes on a Ring

    NASA Astrophysics Data System (ADS)

    Chleboun, Paul; Grosskinsky, Stefan; Pizzoferrato, Andrea

    2017-04-01

    We study lower large deviations for the current of totally asymmetric zero-range processes on a ring with concave current-density relation. We use an approach by Jensen and Varadhan which has previously been applied to exclusion processes, to realize current fluctuations by travelling wave density profiles corresponding to non-entropic weak solutions of the hyperbolic scaling limit of the process. We further establish a dynamic transition, where large deviations of the current below a certain value are no longer typically attained by non-entropic weak solutions, but by condensed profiles, where a non-zero fraction of all the particles accumulates on a single fixed lattice site. This leads to a general characterization of the rate function, which is illustrated by providing detailed results for four generic examples of jump rates, including constant rates, decreasing rates, unbounded sublinear rates and asymptotically linear rates. Our results on the dynamic transition are supported by numerical simulations using a cloning algorithm.

  19. Residual standard deviation: Validation of a new measure of dual-task cost in below-knee prosthesis users.

    PubMed

    Howard, Charla L; Wallace, Chris; Abbas, James; Stokic, Dobrivoje S

    2017-01-01

    We developed and evaluated properties of a new measure of variability in stride length and cadence, termed residual standard deviation (RSD). To calculate RSD, stride length and cadence are regressed against velocity to derive the best fit line from which the variability (SD) of the distance between the actual and predicted data points is calculated. We examined construct, concurrent, and discriminative validity of RSD using dual-task paradigm in 14 below-knee prosthesis users and 13 age- and education-matched controls. Subjects walked first over an electronic walkway while performing separately a serial subtraction and backwards spelling task, and then at self-selected slow, normal, and fast speeds used to derive the best fit line for stride length and cadence against velocity. Construct validity was demonstrated by significantly greater increase in RSD during dual-task gait in prosthesis users than controls (group-by-condition interaction, stride length p=0.0006, cadence p=0.009). Concurrent validity was established against coefficient of variation (CV) by moderate-to-high correlations (r=0.50-0.87) between dual-task cost RSD and dual-task cost CV for both stride length and cadence in prosthesis users and controls. Discriminative validity was documented by the ability of dual-task cost calculated from RSD to effectively differentiate prosthesis users from controls (area under the receiver operating characteristic curve, stride length 0.863, p=0.001, cadence 0.808, p=0.007), which was better than the ability of dual-task cost CV (0.692, 0.648, respectively, not significant). These results validate RSD as a new measure of variability in below-knee prosthesis users. Future studies should include larger cohorts and other populations to ascertain its generalizability. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Prediction of peak response values of structures with and without TMD subjected to random pedestrian flows

    NASA Astrophysics Data System (ADS)

    Lievens, Klaus; Van Nimmen, Katrien; Lombaert, Geert; De Roeck, Guido; Van den Broeck, Peter

    2016-09-01

    In civil engineering and architecture, the availability of high strength materials and advanced calculation techniques enables the construction of slender footbridges, generally highly sensitive to human-induced excitation. Due to the inherent random character of the human-induced walking load, variability on the pedestrian characteristics must be considered in the response simulation. To assess the vibration serviceability of the footbridge, the statistics of the stochastic dynamic response are evaluated by considering the instantaneous peak responses in a time range. Therefore, a large number of time windows are needed to calculate the mean value and standard deviation of the instantaneous peak values. An alternative method to evaluate the statistics is based on the standard deviation of the response and a characteristic frequency as proposed in wind engineering applications. In this paper, the accuracy of this method is evaluated for human-induced vibrations. The methods are first compared for a group of pedestrians crossing a lightly damped footbridge. Small differences of the instantaneous peak value were found by the method using second order statistics. Afterwards, a TMD tuned to reduce the peak acceleration to a comfort value, was added to the structure. The comparison between both methods in made and the accuracy is verified. It is found that the TMD parameters are tuned sufficiently and good agreements between the two methods are found for the estimation of the instantaneous peak response for a strongly damped structure.

  1. Accuracy of the HST Standard Astrometric Catalogs w.r.t. Gaia

    NASA Astrophysics Data System (ADS)

    Kozhurina-Platais, V.; Grogin, N.; Sabbi, E.

    2018-02-01

    The goal of astrometric calibration of the HST ACS/WFC and WFC3/UVIS imaging instruments is to provide a coordinate system free of distortion to the precision level of 0.1 pixel 4-5 mas or better. This astrometric calibration is based on two HST astrometric standard fields in the vicinity of the globular clusters, 47 Tuc and omega Cen, respectively. The derived calibration of the geometric distortion is assumed to be accurate down to 2-3 mas. Is this accuracy in agreement with the true value? Now, with the access to globally accurate positions from the first Gaia data release (DR1), we found that there are measurable offsets, rotation, scale and other deviations of distortion parameters in two HST standard astrometric catalogs. These deviations from the distortion-free and properly aligned coordinate system should be accounted and corrected for, so that the high precision HST positions are free of any systematic errors. We also found that the precision of the HST pixel coordinates is substantially better than the accuracy listed in the Gaia DR1. Therefore, in order to finalize the components of distortion in the HST standard catalogs, the next release of Gaia data is needed.

  2. 9 CFR 381.308 - Deviations in processing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., containers in the retort intake valve and in transfer valves between retort shells at the time of a jam or... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Deviations in processing. 381.308... Deviations in processing. (a) Whenever the actual process is less than the process schedule or when any...

  3. Online Deviation Detection for Medical Processes

    PubMed Central

    Christov, Stefan C.; Avrunin, George S.; Clarke, Lori A.

    2014-01-01

    Human errors are a major concern in many medical processes. To help address this problem, we are investigating an approach for automatically detecting when performers of a medical process deviate from the acceptable ways of performing that process as specified by a detailed process model. Such deviations could represent errors and, thus, detecting and reporting deviations as they occur could help catch errors before harm is done. In this paper, we identify important issues related to the feasibility of the proposed approach and empirically evaluate the approach for two medical procedures, chemotherapy and blood transfusion. For the evaluation, we use the process models to generate sample process executions that we then seed with synthetic errors. The process models describe the coordination of activities of different process performers in normal, as well as in exceptional situations. The evaluation results suggest that the proposed approach could be applied in clinical settings to help catch errors before harm is done. PMID:25954343

  4. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  5. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  6. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 5 2012-04-01 2012-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  7. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 5 2013-04-01 2013-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  8. 21 CFR 330.11 - NDA deviations from applicable monograph.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 5 2014-04-01 2014-04-01 false NDA deviations from applicable monograph. 330.11... EFFECTIVE AND NOT MISBRANDED Administrative Procedures § 330.11 NDA deviations from applicable monograph. A new drug application requesting approval of an OTC drug deviating in any respect from a monograph that...

  9. Assessing Explosives Safety Risks, Deviations, And Consequences

    DTIC Science & Technology

    2009-07-31

    Technical Paper 23 31 July 2009 DDESB Assessing Explosives Safety Risks, Deviations, And Consequences ...Deviations, And Consequences 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER...and approaches to assist warfighters in executing their mission, conserving resources, and maximizing operational effectiveness . When mission risk

  10. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of the landfill monitoring and SSM plan requirements, deviations include the items in paragraphs (a.... (c) A deviation occurs when a SSM plan is not developed or maintained on site. [68 FR 2238, Jan. 16...

  11. 40 CFR 63.1965 - What is a deviation?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of the landfill monitoring and SSM plan requirements, deviations include the items in paragraphs (a.... (c) A deviation occurs when a SSM plan is not developed or maintained on site. [68 FR 2238, Jan. 16...

  12. Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.

    PubMed

    Artes, Paul H; Hutchison, Donna M; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-07-01

    To compare test results from second-generation Frequency-Doubling Technology perimetry (FDT2, Humphrey Matrix; Carl-Zeiss Meditec, Dublin, CA) and standard automated perimetry (SAP) in patients with glaucoma. Specifically, to examine the relationship between visual field sensitivity and test-retest variability and to compare total and pattern deviation probability maps between both techniques. Fifteen patients with glaucoma who had early to moderately advanced visual field loss with SAP (mean MD, -4.0 dB; range, +0.2 to -16.1) were enrolled in the study. Patients attended three sessions. During each session, one eye was examined twice with FDT2 (24-2 threshold test) and twice with SAP (Swedish Interactive Threshold Algorithm [SITA] Standard 24-2 test), in random order. We compared threshold values between FDT2 and SAP at test locations with similar visual field coordinates. Test-retest variability, established in terms of test-retest intervals and standard deviations (SDs), was investigated as a function of visual field sensitivity (estimated by baseline threshold and mean threshold, respectively). The magnitude of visual field defects apparent in total and pattern deviation probability maps were compared between both techniques by ordinal scoring. The global visual field indices mean deviation (MD) and pattern standard deviation (PSD) of FDT2 and SAP correlated highly (r > 0.8; P < 0.001). At test locations with high sensitivity (>25 dB with SAP), threshold estimates from FDT2 and SAP exhibited a close, linear relationship, with a slope of approximately 2.0. However, at test locations with lower sensitivity, the relationship was much weaker and ceased to be linear. In comparison with FDT2, SAP showed a slightly larger proportion of test locations with absolute defects (3.0% vs. 2.2% with SAP and FDT2, respectively, P < 0.001). Whereas SAP showed a significant increase in test-retest variability at test locations with lower sensitivity (P < 0.001), there was no

  13. A systematic review found that deviations from intention-to-treat are common in randomized trials and systematic reviews.

    PubMed

    Abraha, Iosief; Cozzolino, Francesco; Orso, Massimiliano; Marchesi, Mauro; Germani, Antonella; Lombardo, Guido; Eusebi, Paolo; De Florio, Rita; Luchetta, Maria Laura; Iorio, Alfonso; Montedori, Alessandro

    2017-04-01

    To describe the characteristics, and estimate the incidence, of trials included in systematic reviews deviating from the intention-to-treat (ITT) principle. A 5% random sample of reviews were selected (Medline 2006-2010). Trials from reviews were classified based on the ITT: (1) ITT trials (trials reporting standard ITT analyses); (2) modified ITT (mITT) trials (modified ITT; trials deviating from standard ITT); or (3) no ITT trials. Of 222 reviews, 81 (36%) included at least one mITT trial. Reviews with mITT trials were more likely to contain trials that used placebo, that investigated drugs, and that reported favorable results. The incidence of reviews with mITT trial ranged from 29% (17/58) to 48% (23/48). Of the 2,349 trials, 597 (25.4%) were classified as ITT trials, 323 (13.8%) as mITT trials, and 1,429 (60.8%) as no ITT trials. The mITT trials were more likely to have reported exclusions compared to studies classified as ITT trials and to have received funding. The reporting of the type of ITT may differ according to the clinical area and the type of intervention. Deviation from ITT in randomized controlled trials is a widespread phenomenon that significantly affects systematic reviews. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Reference values of anthropometric measurements in Dutch children. The Oosterwolde Study.

    PubMed

    Gerver, W J; Drayer, N M; Schaafsma, W

    1989-03-01

    In the period 1979-1980 the following anthropometric measurements were recorded in 2351 healthy Dutch children from 0-17 years of age: height, weight, sitting height, arm span, lengths of upper-arm, lower-arm and hand, tibial length, foot length, biacromial diameter, biiliacal diameter, and head circumference. Corresponding percentile values were constructed on the basis of normality assumptions, the mean and standard deviation at age t being determined by a cubic spline approximation. The results are compared with other studies and given in the form of growth charts.

  15. Standard Model thermodynamics across the electroweak crossover

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laine, M.; Meyer, M., E-mail: laine@itp.unibe.ch, E-mail: meyer@itp.unibe.ch

    Even though the Standard Model with a Higgs mass m{sub H} = 125GeV possesses no bulk phase transition, its thermodynamics still experiences a 'soft point' at temperatures around T = 160GeV, with a deviation from ideal gas thermodynamics. Such a deviation may have an effect on precision computations of weakly interacting dark matter relic abundances if their mass is in the few TeV range, or on leptogenesis scenarios operating in this temperature range. By making use of results from lattice simulations based on a dimensionally reduced effective field theory, we estimate the relevant thermodynamic functions across the crossover. The resultsmore » are tabulated in a numerical form permitting for their insertion as a background equation of state into cosmological particle production/decoupling codes. We find that Higgs dynamics induces a non-trivial 'structure' visible e.g. in the heat capacity, but that in general the largest radiative corrections originate from QCD effects, reducing the energy density by a couple of percent from the free value even at T > 160GeV.« less

  16. Standard Model thermodynamics across the electroweak crossover

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laine, M.; Meyer, M.

    Even though the Standard Model with a Higgs mass m{sub \\tiny H}=125 GeV possesses no bulk phase transition, its thermodynamics still experiences a “soft point” at temperatures around T=160 GeV, with a deviation from ideal gas thermodynamics. Such a deviation may have an effect on precision computations of weakly interacting dark matter relic abundances if their mass is in the few TeV range, or on leptogenesis scenarios operating in this temperature range. By making use of results from lattice simulations based on a dimensionally reduced effective field theory, we estimate the relevant thermodynamic functions across the crossover. The results are tabulatedmore » in a numerical form permitting for their insertion as a background equation of state into cosmological particle production/decoupling codes. We find that Higgs dynamics induces a non-trivial “structure” visible e.g. in the heat capacity, but that in general the largest radiative corrections originate from QCD effects, reducing the energy density by a couple of percent from the free value even at T>160 GeV.« less

  17. Fatigue, pilot deviations and time of day

    NASA Technical Reports Server (NTRS)

    Baker, Susan P.

    1989-01-01

    The relationships between pilot fatigue, pilot deviations, reported incidents, and time of day are examined. A sample of 200 Aviation Safety Reporting System (ASRS) reports were analyzed from 1985 and 200 reports from 1987, plus 100 reports from late 1987 and early 1988 that were selected because of possible association with fatigue. The FAA pilot deviation data and incident data were analyzed in relation to denominator data that summarized the hourly operations (landings and takeoffs of scheduled flights) at major U.S. airports. Using as numerators FAA data on pilot deviations and incidents reported to the FAA, the rates by time of day were calculated. Pilot age was also analyzed in relation to the time of day, phase of flight, and type of incident.

  18. A comparative appraisal of two equivalence tests for multiple standardized effects.

    PubMed

    Shieh, Gwowen

    2016-04-01

    Equivalence testing is recommended as a better alternative to the traditional difference-based methods for demonstrating the comparability of two or more treatment effects. Although equivalent tests of two groups are widely discussed, the natural extensions for assessing equivalence between several groups have not been well examined. This article provides a detailed and schematic comparison of the ANOVA F and the studentized range tests for evaluating the comparability of several standardized effects. Power and sample size appraisals of the two grossly distinct approaches are conducted in terms of a constraint on the range of the standardized means when the standard deviation of the standardized means is fixed. Although neither method is uniformly more powerful, the studentized range test has a clear advantage in sample size requirements necessary to achieve a given power when the underlying effect configurations are close to the priori minimum difference for determining equivalence. For actual application of equivalence tests and advance planning of equivalence studies, both SAS and R computer codes are available as supplementary files to implement the calculations of critical values, p-values, power levels, and sample sizes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Measuring the nose in septorhinoplasty patients: ultrasonographic standard values and clinical correlations.

    PubMed

    Stenner, Markus; Koopmann, Mario; Rudack, Claudia

    2017-02-01

    Although septorhinoplasty is the most commonly performed operation in plastic surgery, and the surgical plan as well as its outcome is directly related to the configuration of the anatomical structures in the nose, these are not routinely assessed preoperatively. The aim of our study was to evaluate the nasal soft tissue and cartilaginous structures by means of high-resolution ultrasonography to set up clinical correlations and standard values. We examined 44 patients before septorhinoplasty by high-resolution ultrasonography in noncontact mode. All pictures were quantitatively evaluated by measuring 13 lengths and 4 ratios. All patients underwent a rhinomanometry measuring the nasal air flow. Besides others, men as well as older patients have a significantly thicker alar cartilage. Patients with thinner alar cartilages have a significantly smaller interdomal distance as well as significantly thinner upper lateral cartilages. The soft tissue above the bony dorsum was significantly thicker in older patients. Younger patients have significantly thicker soft tissue in relation to their cartilage. Patients with thicker soft tissue and thinner cartilage have a smaller tip. The interdomal distance and the thickness of the cartilaginous septum significantly correlated with the nasal air flow. We set up standard values of nasal structures in septorhinoplasty patients which can be used as reference values. By judging cartilage and soft tissue characteristics preoperatively, relevant factors for distinct procedures could be analyzed and the surgical steps can be better planned. Visualization by ultrasonography enables the surgeon to achieve treatment goals in a more predictable fashion.

  20. A pooled analysis of on-the-road highway driving studies in actual traffic measuring standard deviation of lateral position (i.e., "weaving") while driving at a blood alcohol concentration of 0.5 g/L.

    PubMed

    Jongen, S; Vermeeren, A; van der Sluiszen, N N J J M; Schumacher, M B; Theunissen, E L; Kuypers, K P C; Vuurman, E F P M; Ramaekers, J G

    2017-03-01

    The on-the-road highway driving test is generally regarded as a gold standard for assessing drug-induced driving impairment. The primary outcome measure is the standard deviation of lateral position (SDLP), a measure of road tracking error or "weaving". The test has been calibrated for incremental doses of alcohol almost 30 years ago in order to define the impact of drug-induced impairment in terms of blood alcohol concentration (BAC) equivalents. Drug-induced changes in SDLP exceeding 2.4 cm have been evaluated as clinically relevant ever since. The present analysis was conducted to assess the robustness of the alcohol effect in a range of on-the-road driving studies which have been conducted since the initial alcohol calibration study. The present study pooled data of 182 participants from nine placebo-controlled crossover studies who performed the highway driving test, while their BAC was at or just below the legal limit for drivers (i.e., 0.5 g/L). Overall, mean SDLP increased with 2.5 cm (95% CI 2.0-2.9 cm). Equivalence testing showed that the clinical relevance criterion value of 2.4 cm fell well within the 95% CI in each individual study. Gender did not affect alcohol-induced changes in SDLP. These results demonstrate the robustness and validity of the clinical relevance criterion for SDLP as measured during on-the-road driving.

  1. [Clinical evaluation on the operation of the deviated nose and the deviated nasal septum with the plastic operation--report of 268 cases].

    PubMed

    Wang, Gang; Liu, Liu; Li, Fang

    2011-04-01

    To explore the feasibility of combination plastic operation on the deviation nose and the deviation nasal septum. Design the butterfly cut from the root of the columella nasi to the middle part of each alae nasi. So that the nasal septum, the cartilage septodorsalis and the nose bones could be exposed well. It was key to separate and fix the arch keystone area in the plastic operation of the deviation nose. It was key to separate septal cartilage of nose from the perpendicular plate of ethmoid bone and maxilla nose pun in plastic operation of the deviation nasal septum. Pack the vaseline oil gauze or chitosan reshaping PVA into two side of nasal cavity in order to internal fixation of nasal cavity and prevent the hematoma of nasal septum. The vaseline oil gauze can be pull out on the morning and on the afternoon 24 hours after which can reduce the pain. The external fixation of nasal cavity is not important to which can be omitted. Two hundred and sixty-eight cases after 6 to 24 months follow-up. Two hundred and twenty-eight cases were satisfied. None was unsatisfied. The combination plastic operation on the deviation nose and the deviation nasal septum, could cope with both the beauty problem and reconstruct the nose function.

  2. Association between septal deviation and sinonasal papilloma.

    PubMed

    Nomura, Kazuhiro; Ogawa, Takenori; Sugawara, Mitsuru; Honkura, Yohei; Oshima, Hidetoshi; Arakawa, Kazuya; Oshima, Takeshi; Katori, Yukio

    2013-12-01

    Sinonasal papilloma is a common benign epithelial tumor of the sinonasal tract and accounts for 0.5% to 4% of all nasal tumors. The etiology of sinonasal papilloma remains unclear, although human papilloma virus has been proposed as a major risk factor. Other etiological factors, such as anatomical variations of the nasal cavity, may be related to the pathogenesis of sinonasal papilloma, because deviated nasal septum is seen in patients with chronic rhinosinusitis. We, therefore, investigated the involvement of deviated nasal septum in the development of sinonasal papilloma. Preoperative computed tomography or magnetic resonance imaging findings of 83 patients with sinonasal papilloma were evaluated retrospectively. The side of papilloma and the direction of septal deviation showed a significant correlation. Septum deviated to the intact side in 51 of 83 patients (61.4%) and to the affected side in 18 of 83 patients (21.7%). Straight or S-shaped septum was observed in 14 of 83 patients (16.9%). Even after excluding 27 patients who underwent revision surgery and 15 patients in whom the papilloma touched the concave portion of the nasal septum, the concave side of septal deviation was associated with the development of sinonasal papilloma (p = 0.040). The high incidence of sinonasal papilloma in the concave side may reflect the consequences of the traumatic effects caused by wall shear stress of the high-velocity airflow and the increased chance of inhaling viruses and pollutants. The present study supports the causative role of human papilloma virus and toxic chemicals in the occurrence of sinonasal papilloma.

  3. 40 CFR 792.81 - Standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...

  4. 40 CFR 792.81 - Standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...

  5. 40 CFR 792.81 - Standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...

  6. Comparison of expert and nonexpert swimmers' opinions about the value, potency, and activity of four standard swimming strokes and underwater undulatory swimming.

    PubMed

    Collard, L; Oboeuf, A

    2009-04-01

    Underwater undulatory swimming (UUS) is often perceived to be a nonessential aspect of aquatic propulsion. Given their solid theoretical and practical training in swimming, physical education students should be capable of judging the true value of the "fifth stroke," since it appears to be the most efficient technique in high level, competitive swimming. To compare opinions and connotations associated with the stroke and the four official strokes (butterfly, backstroke, breaststroke, and crawl), 198 students (32 of whom were expert swimmers; M age = 20.6 yr., SD = 1.2), were surveyed using the semantic differential of Osgood, Suci, and Tannenbaum. Although answers of expert and nonexpert swimmers differed significantly (p < .01, except for the breaststroke), participants considered overall that undulatory stroke was less attractive, less powerful, and less rapid than the four surface strokes (d = 2.88 for the expert swimmers). Putting one arm in front of the other and repeating the sequence still remains the most solidly held representation of "the right way" to swim. However, the high observed standard deviations for the underwater undulatory stimulus (SD > or = 1.1 with SD max = 3 for the expert swimmers) attests to the view being less strongly held by swimming specialists.

  7. Impact of the definition of peak standardized uptake value on quantification of treatment response.

    PubMed

    Vanderhoek, Matt; Perlman, Scott B; Jeraj, Robert

    2012-01-01

    PET-based treatment response assessment typically measures the change in maximum standardized uptake value (SUV(max)), which is adversely affected by noise. Peak SUV (SUV(peak)) has been recommended as a more robust alternative, but its associated region of interest (ROI(peak)) is not uniquely defined. We investigated the impact of different ROI(peak) definitions on quantification of SUV(peak) and tumor response. Seventeen patients with solid malignancies were treated with a multitargeted receptor tyrosine kinase inhibitor resulting in a variety of responses. Using the cellular proliferation marker 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), whole-body PET/CT scans were acquired at baseline and during treatment. (18)F-FLT-avid lesions (∼2/patient) were segmented on PET images, and tumor response was assessed via the relative change in SUV(peak). For each tumor, 24 different SUV(peaks) were determined by changing ROI(peak) shape (circles vs. spheres), size (7.5-20 mm), and location (centered on SUV(max) vs. placed in highest-uptake region), encompassing different definitions from the literature. Within each tumor, variations in the 24 SUV(peaks) and tumor responses were measured using coefficient of variation (CV), standardized deviation (SD), and range. For each ROI(peak) definition, a population average SUV(peak) and tumor response were determined over all tumors. A substantial variation in both SUV(peak) and tumor response resulted from changing the ROI(peak) definition. The variable ROI(peak) definition led to an intratumor SUV(peak) variation ranging from 49% above to 46% below the mean (CV, 17%) and an intratumor SUV(peak) response variation ranging from 49% above to 35% below the mean (SD, 9%). The variable ROI(peak) definition led to a population average SUV(peak) variation ranging from 24% above to 28% below the mean (CV, 14%) and a population average SUV(peak) response variation ranging from only 3% above to 3% below the mean (SD, 2%). The size of ROI

  8. [Reference values for lead levels in blood for the urban population].

    PubMed

    Paolielo, M M; Gutierrez, P R; Turini, C A; Matsuo, T; Mezzaroba, L; Barbosa, D S; Alvarenga, A L; Carvalho, S R; Figueiroa, G A; Leite, V G; Gutierrez, A C; Nogueira, K B; Inamine, W A; Zavatti, A M

    1997-04-01

    The lead reference values for blood used in Brazil come from studies conducted in other countries, where socioeconomic, clinical, nutritional and occupational conditions are significantly different. In order to guarantee an accurate biomonitoring of the population which is occupationally exposed to lead, a major health concern of the studied community, reference values for individuals who are not occupationally exposed and who live in the southern region of the city were established. The sample was composed of 206 subjects of at least 15 years of age. Various strategies were employed to assure good-quality sampling. Subjects who presented values outside clinical or laboratory norms were excluded, as well as those whose specific activities might interfere with the results. Lead reference values for blood were found to be from 2.40 to 16.6 micrograms.dL-1, obtained by the interval x +/- 2s (where x is the mean and s is the standard deviation form observed values) and the median was 7.9 micrograms.dL-1.

  9. Perception of aircraft Deviation Cues

    NASA Technical Reports Server (NTRS)

    Martin, Lynne; Azuma, Ronald; Fox, Jason; Verma, Savita; Lozito, Sandra

    2005-01-01

    To begin to address the need for new displays, required by a future airspace concept to support new roles that will be assigned to flight crews, a study of potentially informative display cues was undertaken. Two cues were tested on a simple plan display - aircraft trajectory and flight corridor. Of particular interest was the speed and accuracy with which participants could detect an aircraft deviating outside its flight corridor. Presence of the trajectory cue significantly reduced participant reaction time to a deviation while the flight corridor cue did not. Although non-significant, the flight corridor cue seemed to have a relationship with the accuracy of participants judgments rather than their speed. As this is the second of a series of studies, these issues will be addressed further in future studies.

  10. Mass and Double-Beta-Decay Q Value of Xe136

    NASA Astrophysics Data System (ADS)

    Redshaw, Matthew; Wingfield, Elizabeth; McDaniel, Joseph; Myers, Edmund G.

    2007-02-01

    The atomic mass of Xe136 has been measured by comparing cyclotron frequencies of single ions in a Penning trap. The result, with 1 standard deviation uncertainty, is M(Xe136)=135.907 214 484 (11) u. Combined with previous results for the mass of Ba136 [Audi, Wapstra, and Thibault, Nucl. Phys. A 729, 337 (2003)NUPABL0375-947410.1016/j.nuclphysa.2003.11.003], this gives a Q value (M[Xe136]-M[Ba136])c2=2457.83(37)keV, sufficiently precise for ongoing searches for the neutrinoless double-beta decay of Xe136.

  11. Research on the preparation, uniformity and stability of mixed standard substance for rapid detection of goat milk composition.

    PubMed

    Zhu, Yuying; Wang, Jianmin; Wang, Cunfang

    2018-05-01

    Taking fresh goat milk as raw material after filtering, centrifuging, hollow fiber ultrafiltration, allocating formula, value detection and preparation processing, a set of 10 goat milk mixed standard substances was prepared on the basis of one-factor-at-a-time using a uniform design method, and its accuracy, uniformity and stability were evaluated by paired t-test and F-test of one-way analysis of variance. The results showed that three milk composition contents of these standard products were independent of each other, and the preparation using the quasi-level design method, and without emulsifier was the best program. Compared with detection value by cow milk standards for calibration fast analyzer, the calibration by goat milk mixed standard was more applicable to rapid detection of goat milk composition, detection value was more accurate and the deviation showed less error. Single factor analysis of variance showed that the uniformity and stability of the mixed standard substance were better; it could be stored for 15 days at 4°C. The uniformity and stability of the in-units and inter-units could meet the requirements of the preparation of national standard products. © 2018 Japanese Society of Animal Science.

  12. Linear versus non-linear measures of temporal variability in finger tapping and their relation to performance on open- versus closed-loop motor tasks: comparing standard deviations to Lyapunov exponents.

    PubMed

    Christman, Stephen D; Weaver, Ryan

    2008-05-01

    The nature of temporal variability during speeded finger tapping was examined using linear (standard deviation) and non-linear (Lyapunov exponent) measures. Experiment 1 found that right hand tapping was characterised by lower amounts of both linear and non-linear measures of variability than left hand tapping, and that linear and non-linear measures of variability were often negatively correlated with one another. Experiment 2 found that increased non-linear variability was associated with relatively enhanced performance on a closed-loop motor task (mirror tracing) and relatively impaired performance on an open-loop motor task (pointing in a dark room), especially for left hand performance. The potential uses and significance of measures of non-linear variability are discussed.

  13. Analysis and interpretation of stress indicators in deviated wells of the Coso Geothermal Field

    USGS Publications Warehouse

    Schoenball, Martin; Glen, Jonathan M. G.; Davatzes, Nicholas C.

    2016-01-01

    Characterizing the tectonic stress field is an integral part of the development of hydrothermal systems and especially for enhanced geothermal systems (EGS). With a well characterized stress field the propensity of fault slip on faults with known location and orientation can be identified. Faults that are critically oriented for faulting with respect to the stress field are known to provide natural fluid pathways. A high slip tendency makes a fault a likely candidate for reactivation during the creation of an EGS. Similarly, the stress state provides insight for the potential of larger, damaging earthquakes should extensive portions of well-oriented, larger faults be reactivated.The analysis of stress indicators such as drilling-induced fractures and borehole breakouts is the main tool to infer information on the stress state of a geothermal reservoir. The standard procedure is applicable to sub-vertical wellbore sections and highly deviated sections have to be discarded. However, in order to save costs and reduce the environmental impact most recent wells are directionally drilled with deviations that require appropriate consideration of the deviated trajectory. Here we present an analysis scheme applicable to arbitrary well trajectories or a combination of wells to infer the stress state. Through the sampling of the stress tensor along several directions additional information on the stress regime and even relative stress magnitudes can be obtained. We apply this method on image logs from the pair of wells 58-10 and 58A-10 that were drilled from the same well pad. Both wells have image logs of about 2km of their trajectories that are separated by less than 300m. For both wells we obtain a mean orientation of SHmax of N23° with large standard deviations of locations of stress indicators of 24° and 26°, respectively. While the local stress direction is highly variable along both wells with dominant wavelengths from around 50 to 500m, the mean directions are very

  14. Application of Mean of Absolute Deviation Method for the Selection of Best Nonlinear Component Based on Video Encryption

    NASA Astrophysics Data System (ADS)

    Anees, Amir; Khan, Waqar Ahmad; Gondal, Muhammad Asif; Hussain, Iqtadar

    2013-07-01

    The aim of this work is to make use of the mean of absolute deviation (MAD) method for the evaluation process of substitution boxes used in the advanced encryption standard. In this paper, we use the MAD technique to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, MAD is applied to advanced encryption standard (AES), affine power affine (APA), Gray, Lui J., Residue Prime, S8 AES, SKIPJACK, and Xyi substitution boxes.

  15. Nasal Septal Deviations: A Systematic Review of Classification Systems.

    PubMed

    Teixeira, Jeffrey; Certal, Victor; Chang, Edward T; Camacho, Macario

    2016-01-01

    Objective. To systematically review the international literature for internal nasal septal deviation classification systems and summarize them for clinical and research purposes. Data Sources. Four databases (including PubMed/MEDLINE) were systematically searched through December 16, 2015. Methods. Systematic review, adhering to PRISMA. Results. After removal of duplicates, this study screened 952 articles for relevance. A final comprehensive review of 50 articles identified that 15 of these articles met the eligibility criteria. The classification systems defined in these articles included C-shaped, S-shaped, reverse C-shaped, and reverse S-shaped descriptions of the septal deviation in both the cephalocaudal and anteroposterior dimensions. Additional studies reported use of computed tomography and categorized deviation based on predefined locations. Three studies graded the severity of septal deviations based on the amount of deflection. The systems defined in the literature also included an evaluation of nasal septal spurs and perforations. Conclusion. This systematic review ascertained that the majority of the currently published classification systems for internal nasal septal deviations can be summarized by C-shaped or reverse C-shaped, as well as S-shaped or reverse S-shaped deviations in the anteroposterior and cephalocaudal dimensions. For imaging studies, predefined points have been defined along the septum. Common terminology can facilitate future research.

  16. 38 CFR 36.4304 - Deviations; changes of identity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  17. 38 CFR 36.4304 - Deviations; changes of identity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  18. 38 CFR 36.4304 - Deviations; changes of identity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  19. 38 CFR 36.4304 - Deviations; changes of identity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  20. 38 CFR 36.4304 - Deviations; changes of identity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... identity. 36.4304 Section 36.4304 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS... Deviations; changes of identity. A deviation of more than 5 percent between the estimates upon which a... change in the identity of the property upon which the original appraisal was based, will invalidate the...

  1. An accurate estimation method of kinematic viscosity for standard viscosity liquids

    NASA Astrophysics Data System (ADS)

    Kurano, Y.; Kobayashi, H.; Yoshida, K.; Imai, H.

    1992-07-01

    Deming's method of least squares is introduced to make an accurate kinematic viscosity estimation for a series of 13 standard-viscosity liquids at any desired temperature. The empirical ASTM kinematic viscosity-temperature equation is represented in the form loglog( v+c)=a-b log T, where v (in mm2. s-1) is the kinematic viscosity at temperature T (in K), a and b are the constants for a given liquid, and c has a variable value. In the present application, however, c is assumed to have a constant value for each standard-viscosity liquid, as do a and b in the ASTM equation. This assumption has since been verified experimentally for all standard-viscosity liquids. The kinematic viscosities for the 13 standard-viscosity liquids have been measured with a high accuracy in the temperature range of 20 40°C using a series of the NRLM capillary master viscometers with an automatic flow time detection system. The deviations between measured and estimated kinematic viscosities were less than ±0.04% for the 10 standard-viscosity liquids JS2.5 to JS2000 and ±0.11% for the 3 standard-viscosity liquids JS15H to JS200H, respectively. From the above investigation, it was revealed that the uncertainty in the present estimation method is less than one-third that in the usual ASTM method.

  2. Explorations in Statistics: Standard Deviations and Standard Errors

    ERIC Educational Resources Information Center

    Curran-Everett, Douglas

    2008-01-01

    Learning about statistics is a lot like learning about science: the learning is more meaningful if you can actively explore. This series in "Advances in Physiology Education" provides an opportunity to do just that: we will investigate basic concepts in statistics using the free software package R. Because this series uses R solely as a vehicle…

  3. Influence of occlusal plane inclination and mandibular deviation on esthetics

    PubMed Central

    Corte, Cristiane Cherobini Dalla; da Silveira, Bruno Lopes; Marquezan, Mariana

    2015-01-01

    Objective: The aim of this study was to assess the degree of perception of occlusal plane inclination and mandibular deviation in facial esthetics, assessed by laypeople, dentists and orthodontists. Methods: A woman with 5.88° of inclination and 5.54 mm of mandibular deviation was selected and, based on her original photograph, four new images were created correcting the deviations and creating more symmetric faces and smiles. Examiners assessed the images by means of a questionnaire. Their opinions were compared by qualitative and quantitative analyses. Results: A total of 45 laypeople, 27 dentists and 31 orthodontists filled out the questionnaires. All groups were able to perceive the asymmetry; however, orthodontists were more sensitive, identifying asymmetries as from 4.32° of occlusal plane inclination and 4.155 mm of mandibular deviation (p< 0.05). The other categories of evaluators identified asymmetries and assigned significantly lower grades, starting from 5.88° of occlusal plane inclination and 5.54 mm of mandibular deviation (p< 0.05). Conclusion: Occlusal plane inclination and mandibular deviation were perceived by all groups, but orthodontists presented higher perception of deviations. PMID:26560821

  4. 77 FR 74985 - Water Quality Standards for the State of Florida's Streams and Downstream Protection Values for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-18

    ... pollution in fresh water systems can significantly negatively impact aquatic life and long-term ecosystem... Water Quality Standards for the State of Florida's Streams and Downstream Protection Values for Lakes... its numeric water quality standards for nutrients in Florida that were promulgated and published on...

  5. Density Large Deviations for Multidimensional Stochastic Hyperbolic Conservation Laws

    NASA Astrophysics Data System (ADS)

    Barré, J.; Bernardin, C.; Chetrite, R.

    2018-02-01

    We investigate the density large deviation function for a multidimensional conservation law in the vanishing viscosity limit, when the probability concentrates on weak solutions of a hyperbolic conservation law. When the mobility and diffusivity matrices are proportional, i.e. an Einstein-like relation is satisfied, the problem has been solved in Bellettini and Mariani (Bull Greek Math Soc 57:31-45, 2010). When this proportionality does not hold, we compute explicitly the large deviation function for a step-like density profile, and we show that the associated optimal current has a non trivial structure. We also derive a lower bound for the large deviation function, valid for a more general weak solution, and leave the general large deviation function upper bound as a conjecture.

  6. Effect of multizone refractive multifocal contact lenses on standard automated perimetry.

    PubMed

    Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa

    2012-09-01

    The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.

  7. Event-specific qualitative and quantitative detection of five genetically modified rice events using a single standard reference molecule.

    PubMed

    Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong

    2017-07-01

    One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. State insurance exchanges face challenges in offering standardized choices alongside innovative value-based insurance.

    PubMed

    Corlette, Sabrina; Downs, David; Monahan, Christine H; Yondorf, Barbara

    2013-02-01

    Value-based insurance is a relatively new approach to health insurance in which financial barriers, such as copayments, are lowered for clinical services that are considered high value, while consumer cost sharing may be increased for services considered to be of uncertain value. Such plans are complex and do not easily fit into the simplified, consumer-friendly comparison tools that many state health insurance exchanges are formulating for use in 2014. Nevertheless some states and plans are attempting to strike the right balance between a streamlined health exchange shopping experience and innovative, albeit complex, benefit design that promotes value. For example, agencies administering exchanges in Vermont and Oregon are contemplating offering value-based insurance plans as an option in addition to a set of standardized plans. In the postreform environment, policy makers must find ways to present complex value-based insurance plans in a way that consumers and employers can more readily understand.

  9. Endometrioid adenocarcinoma of the uterus with a minimal deviation invasive pattern.

    PubMed

    Landry, D; Mai, K T; Senterman, M K; Perkins, D G; Yazdi, H M; Veinot, J P; Thomas, J

    2003-01-01

    Minimal deviation adenocarcinoma of endometrioid type is a rare pathological entity. We describe a variant of typical endometrioid adenocarcinoma associated with minimal deviation adenocarcinoma of endometrioid type. One 'pilot' case of minimal deviation adenocarcinoma of endometrioid type associated with typical endometrioid adenocarcinoma was encountered at our institution in 2001. A second case of same type was received in consultation. We reviewed 168 consecutive hysterectomy specimens diagnosed with 'endometrioid adenocarcinoma' specifically to identify areas of minimal deviation adenocarcinoma of endometrioid type. Immunohistochemistry was done with the following antibodies: MIB1, p53, oestrogen receptor (ER), progesterone receptor (PR), cytokeratin 7 (CK7), cytokeratin 20 (CK20), carcinoembryonic antigen (CEA), and vimentin (VIM). Four additional cases of minimal deviation adenocarcinoma of endometrioid type were identified. All six cases of minimal deviation adenocarcinoma of endometrioid type were associated with superficial endometrioid adenocarcinoma. In two cases with a large amount of minimal deviation adenocarcinoma of endometrioid type, the cervix was involved. The immunoprofile of two representative cases was ER+, PR+, CK7+, CK20-, CEA-, VIM+. MIB1 immunostaining of four cases revealed little proliferative activity of the minimal deviation adenocarcinoma of endometrioid type glandular cells (0-1%) compared with the associated 'typical' endometrioid adenocarcinoma (20-30%). The same four cases showed no p53 immunostaining in minimal deviation adenocarcinoma of endometrioid type compared with a range of positive staining in the associated endometrioid adenocarcinoma. Minimal deviation adenocarcinoma of endometrioid type more often develops as a result of differentiation from typical endometrioid adenocarcinoma than de novo. Due to its deceptively benign microscopic appearance, minimal deviation adenocarcinoma of endometrioid type may be overlooked and

  10. Stone heterogeneity index as the standard deviation of Hounsfield units: A novel predictor for shock-wave lithotripsy outcomes in ureter calculi.

    PubMed

    Lee, Joo Yong; Kim, Jae Heon; Kang, Dong Hyuk; Chung, Doo Yong; Lee, Dae Hun; Do Jung, Hae; Kwon, Jong Kyou; Cho, Kang Su

    2016-04-01

    We investigated whether stone heterogeneity index (SHI), which a proxy of such variations, was defined as the standard deviation of a Hounsfield unit (HU) on non-contrast computed tomography (NCCT), can be a novel predictor for shock-wave lithotripsy (SWL) outcomes in patients with ureteral stones. Medical records were obtained from the consecutive database of 1,519 patients who underwent the first session of SWL for urinary stones between 2005 and 2013. Ultimately, 604 patients with radiopaque ureteral stones were eligible for this study. Stone related variables including stone size, mean stone density (MSD), skin-to-stone distance, and SHI were obtained on NCCT. Patients were classified into the low and high SHI groups using mean SHI and compared. One-session success rate in the high SHI group was better than in the low SHI group (74.3% vs. 63.9%, P = 0.008). Multivariate logistic regression analyses revealed that smaller stone size (OR 0.889, 95% CI: 0.841-0.937, P < 0.001), lower MSD (OR 0.995, 95% CI: 0.994-0.996, P < 0.001), and higher SHI (OR 1.011, 95% CI: 1.008-1.014, P < 0.001) were independent predictors of one-session success. The radiologic heterogeneity of urinary stones or SHI was an independent predictor for SWL success in patients with ureteral calculi and a useful clinical parameter for stone fragility.

  11. 20 CFR 435.4 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Deviations. 435.4 Section 435.4 Employees' Benefits SOCIAL SECURITY ADMINISTRATION UNIFORM ADMINISTRATIVE REQUIREMENTS FOR GRANTS AND AGREEMENTS WITH INSTITUTIONS OF HIGHER EDUCATION, HOSPITALS, OTHER NON-PROFIT ORGANIZATIONS, AND COMMERCIAL ORGANIZATIONS...

  12. 7 CFR 3430.3 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Deviations. 3430.3 Section 3430.3 Agriculture Regulations of the Department of Agriculture (Continued) NATIONAL INSTITUTE OF FOOD AND AGRICULTURE COMPETITIVE AND NONCOMPETITIVE NON-FORMULA FEDERAL ASSISTANCE PROGRAMS-GENERAL AWARD ADMINISTRATIVE PROVISIONS...

  13. Some clarifications about the Bohmian geodesic deviation equation and Raychaudhuri’s equation

    NASA Astrophysics Data System (ADS)

    Rahmani, Faramarz; Golshani, Mehdi

    2018-01-01

    One of the important and famous topics in general theory of relativity and gravitation is the problem of geodesic deviation and its related singularity theorems. An interesting subject is the investigation of these concepts when quantum effects are considered. Since the definition of trajectory is not possible in the framework of standard quantum mechanics (SQM), we investigate the problem of geodesic equation and its related topics in the framework of Bohmian quantum mechanics in which the definition of trajectory is possible. We do this in a fixed background and we do not consider the backreaction effects of matter on the space-time metric.

  14. Estimation of social value of statistical life using willingness-to-pay method in Nanjing, China.

    PubMed

    Yang, Zhao; Liu, Pan; Xu, Xin

    2016-10-01

    Rational decision making regarding the safety related investment programs greatly depends on the economic valuation of traffic crashes. The primary objective of this study was to estimate the social value of statistical life in the city of Nanjing in China. A stated preference survey was conducted to investigate travelers' willingness to pay for traffic risk reduction. Face-to-face interviews were conducted at stations, shopping centers, schools, and parks in different districts in the urban area of Nanjing. The respondents were categorized into two groups, including motorists and non-motorists. Both the binary logit model and mixed logit model were developed for the two groups of people. The results revealed that the mixed logit model is superior to the fixed coefficient binary logit model. The factors that significantly affect people's willingness to pay for risk reduction include income, education, gender, age, drive age (for motorists), occupation, whether the charged fees were used to improve private vehicle equipment (for motorists), reduction in fatality rate, and change in travel cost. The Monte Carlo simulation method was used to generate the distribution of value of statistical life (VSL). Based on the mixed logit model, the VSL had a mean value of 3,729,493 RMB ($586,610) with a standard deviation of 2,181,592 RMB ($343,142) for motorists; and a mean of 3,281,283 RMB ($505,318) with a standard deviation of 2,376,975 RMB ($366,054) for non-motorists. Using the tax system to illustrate the contribution of different income groups to social funds, the social value of statistical life was estimated. The average social value of statistical life was found to be 7,184,406 RMB ($1,130,032). Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Improving image-quality of interference fringes of out-of-plane vibration using temporal speckle pattern interferometry and standard deviation for piezoelectric plates.

    PubMed

    Chien-Ching Ma; Ching-Yuan Chang

    2013-07-01

    Interferometry provides a high degree of accuracy in the measurement of sub-micrometer deformations; however, the noise associated with experimental measurement undermines the integrity of interference fringes. This study proposes the use of standard deviation in the temporal domain to improve the image quality of patterns obtained from temporal speckle pattern interferometry. The proposed method combines the advantages of both mean and subtractive methods to remove background noise and ambient disturbance simultaneously, resulting in high-resolution images of excellent quality. The out-of-plane vibration of a thin piezoelectric plate is the main focus of this study, providing information useful to the development of energy harvesters. First, ten resonant states were measured using the proposed method, and both mode shape and resonant frequency were investigated. We then rebuilt the phase distribution of the first resonant mode based on the clear interference patterns obtained using the proposed method. This revealed instantaneous deformations in the dynamic characteristics of the resonant state. The proposed method also provides a frequency-sweeping function, facilitating its practical application in the precise measurement of resonant frequency. In addition, the mode shapes and resonant frequencies obtained using the proposed method were recorded and compared with results obtained using finite element method and laser Doppler vibrometery, which demonstrated close agreement.

  16. Mass and Double-Beta-Decay Q Value of {sup 136}Xe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redshaw, Matthew; Wingfield, Elizabeth; McDaniel, Joseph

    The atomic mass of {sup 136}Xe has been measured by comparing cyclotron frequencies of single ions in a Penning trap. The result, with 1 standard deviation uncertainty, is M({sup 136}Xe)=135.907 214 484 (11) u. Combined with previous results for the mass of {sup 136}Ba [Audi, Wapstra, and Thibault, Nucl. Phys. A 729, 337 (2003)], this gives a Q value (M[{sup 136}Xe]-M[{sup 136}Ba])c{sup 2}=2457.83(37) keV, sufficiently precise for ongoing searches for the neutrinoless double-beta decay of {sup 136}Xe.

  17. Blood pressure variability in man: its relation to high blood pressure, age and baroreflex sensitivity.

    PubMed

    Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A

    1980-12-01

    1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.

  18. Standardized Uptake Value Ratio-Independent Evaluation of Brain Amyloidosis.

    PubMed

    Chincarini, Andrea; Sensi, Francesco; Rei, Luca; Bossert, Irene; Morbelli, Silvia; Guerra, Ugo Paolo; Frisoni, Giovanni; Padovani, Alessandro; Nobili, Flavio

    2016-10-18

    The assessment of in vivo18F images targeting amyloid deposition is currently carried on by visual rating with an optional quantification based on standardized uptake value ratio (SUVr) measurements. We target the difficulties of image reading and possible shortcomings of the SUVr methods by validating a new semi-quantitative approach named ELBA. ELBA involves a minimal image preprocessing and does not rely on small, specific regions of interest (ROIs). It evaluates the whole brain and delivers a geometrical/intensity score to be used for ranking and dichotomic assessment. The method was applied to adniimages 18F-florbetapir images from the ADNI database. Five expert readers provided visual assessment in blind and open sessions. The longitudinal trend and the comparison to SUVr measurements were also evaluated. ELBA performed with area under the roc curve (AUC) = 0.997 versus the visual assessment. The score was significantly correlated to the SUVr values (r = 0.86, p < 10-4). The longitudinal analysis estimated a test/retest error of ≃2.3%. Cohort and longitudinal analysis suggests that the ELBA method accurately ranks the brain amyloid burden. The expert readers confirmed its relevance in aiding the visual assessment in a significant number (85) of difficult cases. Despite the good performance, poor and uneven image quality constitutes the major limitation.

  19. The Value Estimation of an HFGW Frequency Time Standard for Telecommunications Network Optimization

    NASA Astrophysics Data System (ADS)

    Harper, Colby; Stephenson, Gary

    2007-01-01

    The emerging technology of gravitational wave control is used to augment a communication system using a development roadmap suggested in Stephenson (2003) for applications emphasized in Baker (2005). In the present paper consideration is given to the value of a High Frequency Gravitational Wave (HFGW) channel purely as providing a method of frequency and time reference distribution for use within conventional Radio Frequency (RF) telecommunications networks. Specifically, the native value of conventional telecommunications networks may be optimized by using an unperturbed frequency time standard (FTS) to (1) improve terminal navigation and Doppler estimation performance via improved time difference of arrival (TDOA) from a universal time reference, and (2) improve acquisition speed, coding efficiency, and dynamic bandwidth efficiency through the use of a universal frequency reference. A model utilizing a discounted cash flow technique provides an estimation of the additional value using HFGW FTS technology could bring to a mixed technology HFGW/RF network. By applying a simple net present value analysis with supporting reference valuations to such a network, it is demonstrated that an HFGW FTS could create a sizable improvement within an otherwise conventional RF telecommunications network. Our conservative model establishes a low-side value estimate of approximately 50B USD Net Present Value for an HFGW FTS service, with reasonable potential high-side values to significant multiples of this low-side value floor.

  20. A General Conditional Large Deviation Principle

    DOE PAGES

    La Cour, Brian R.; Schieve, William C.

    2015-07-18

    Given a sequence of Borel probability measures on a Hausdorff space which satisfy a large deviation principle (LDP), we consider the corresponding sequence of measures formed by conditioning on a set B. If the large deviation rate function I is good and effectively continuous, and the conditioning set has the property that (1)more » $$\\overline{B°}$$=$$\\overline{B}$$ and (2) I(x)<∞ for all xε$$\\overline{B}$$, then the sequence of conditional measures satisfies a LDP with the good, effectively continuous rate function I B, where I B(x)=I(x)-inf I(B) if xε$$\\overline{B}$$ and I B(x)=∞ otherwise.« less

  1. Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index.

    PubMed

    Xue, Wufeng; Zhang, Lei; Mou, Xuanqin; Bovik, Alan C

    2014-02-01

    It is an important task to faithfully evaluate the perceptual quality of output images in many applications, such as image compression, image restoration, and multimedia streaming. A good image quality assessment (IQA) model should not only deliver high quality prediction accuracy, but also be computationally efficient. The efficiency of IQA metrics is becoming particularly important due to the increasing proliferation of high-volume visual data in high-speed networks. We present a new effective and efficient IQA model, called gradient magnitude similarity deviation (GMSD). The image gradients are sensitive to image distortions, while different local structures in a distorted image suffer different degrees of degradations. This motivates us to explore the use of global variation of gradient based local quality map for overall image quality prediction. We find that the pixel-wise gradient magnitude similarity (GMS) between the reference and distorted images combined with a novel pooling strategy-the standard deviation of the GMS map-can predict accurately perceptual image quality. The resulting GMSD algorithm is much faster than most state-of-the-art IQA methods, and delivers highly competitive prediction accuracy. MATLAB source code of GMSD can be downloaded at http://www4.comp.polyu.edu.hk/~cslzhang/IQA/GMSD/GMSD.htm.

  2. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    PubMed

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  3. Approaching sub-50 nanoradian measurements by reducing the saw-tooth deviation of the autocollimator in the Nano-Optic-Measuring Machine

    NASA Astrophysics Data System (ADS)

    Qian, Shinan; Geckeler, Ralf D.; Just, Andreas; Idir, Mourad; Wu, Xuehui

    2015-06-01

    Since the development of the Nano-Optic-Measuring Machine (NOM), the accuracy of measuring the profile of an optical surface has been enhanced to the 100-nrad rms level or better. However, to update the accuracy of the NOM system to sub-50 nrad rms, the large saw-tooth deviation (269 nrad rms) of an existing electronic autocollimator, the Elcomat 3000/8, must be resolved. We carried out simulations to assess the saw-tooth-like deviation. We developed a method for setting readings to reduce the deviation to sub-50 nrad rms, suitable for testing plane mirrors. With this method, we found that all the tests conducted in a slowly rising section of the saw-tooth show a small deviation of 28.8 to <40 nrad rms. We also developed a dense-measurement method and an integer-period method to lower the saw-tooth deviation during tests of sphere mirrors. Further research is necessary for formulating a precise test for a spherical mirror. We present a series of test results from our experiments that verify the value of the improvements we made.

  4. 2 CFR 170.115 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 2 Grants and Agreements 1 2012-01-01 2012-01-01 false Deviations. 170.115 Section 170.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS NATIONAL POLICY REQUIREMENTS REPORTING...

  5. 2 CFR 170.115 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Deviations. 170.115 Section 170.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS Reserved REPORTING SUBAWARD AND EXECUTIVE...

  6. 2 CFR 170.115 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 2 Grants and Agreements 1 2013-01-01 2013-01-01 false Deviations. 170.115 Section 170.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS NATIONAL POLICY REQUIREMENTS REPORTING...

  7. 2 CFR 170.115 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 2 Grants and Agreements 1 2011-01-01 2011-01-01 false Deviations. 170.115 Section 170.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS [Reserved] REPORTING SUBAWARD AND...

  8. 48 CFR 2901.405 - Deviations pertaining to treaties and executive agreements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DOLAR 2901.405 Deviations pertaining to treaties and executive agreements. (a) The Director, DAMS is... deviations not authorized by FAR 1.405(b) or (c), the Director, DAMS, will process the request for deviation...

  9. 48 CFR 2901.405 - Deviations pertaining to treaties and executive agreements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DOLAR 2901.405 Deviations pertaining to treaties and executive agreements. (a) The Director, DAMS is... deviations not authorized by FAR 1.405(b) or (c), the Director, DAMS, will process the request for deviation...

  10. Complexity analysis based on generalized deviation for financial markets

    NASA Astrophysics Data System (ADS)

    Li, Chao; Shang, Pengjian

    2018-03-01

    In this paper, a new modified method is proposed as a measure to investigate the correlation between past price and future volatility for financial time series, known as the complexity analysis based on generalized deviation. In comparison with the former retarded volatility model, the new approach is both simple and computationally efficient. The method based on the generalized deviation function presents us an exhaustive way showing the quantization of the financial market rules. Robustness of this method is verified by numerical experiments with both artificial and financial time series. Results show that the generalized deviation complexity analysis method not only identifies the volatility of financial time series, but provides a comprehensive way distinguishing the different characteristics between stock indices and individual stocks. Exponential functions can be used to successfully fit the volatility curves and quantify the changes of complexity for stock market data. Then we study the influence for negative domain of deviation coefficient and differences during the volatile periods and calm periods. after the data analysis of the experimental model, we found that the generalized deviation model has definite advantages in exploring the relationship between the historical returns and future volatility.

  11. The Effect of a Combination of Implant Controller and Handpiece from Different Manufacturers on the Torque Value.

    PubMed

    Lee, Du-Hyeong; Kim, Yong-Gun; Lee, Jong-Ho; Hong, Sam-Pyo; Lim, Young-Jun; Lee, Kyu-Bok

    2015-01-01

    To determine the accuracy of applied torque of different implant controller and handpiece combinations by using an electronic torque gauge. Four combinations of the following devices were tested: Surgic XT controller (NSK), XIP10 controller (Saeshin), X-SG20L handpiece (NSK), CRB26LX handpiece (Saeshin). For five torque settings, 30 measurements were recorded at 30 revolutions per minute by using an electronic torque gauge fixed to jigs, and means were calculated. Applied torques were generally higher than the set torque of 10 and 20 Ncm and lower than the set values of 40 and 50 Ncm. The average torque deviations differed significantly among the combinations (P < .05). At 10 and 20 Ncm, the Surgic XT/X-SG20L combination yielded the closest value to the intended torque, followed by the XIP10/X-SG20L combination. At 30 Ncm, the XIP10/X-SG20L combination showed the nearest value. At 40 Ncm, the Surgic XT/X-SG20L, XIP10/CRB26LX, and XIP10/X-SG20L combinations showed deviations within 10%. At 50 Ncm, all the combinations showed lower applied torque than the set value. Large standard deviations were observed in the Surgic XT/CRB26LX (13.288) and Surgic XT/X-SG20L (7.858) combinations. Different combinations of implant controllers and handpieces do not generate significant variations in applied torque. The actual torque varies according to the torque setting. It is necessary to calibrate devices before use to reduce potentially problematic torque.

  12. A proof for Rhiel's range estimator of the coefficient of variation for skewed distributions.

    PubMed

    Rhiel, G Steven

    2007-02-01

    In this research study is proof that the coefficient of variation (CV(high-low)) calculated from the highest and lowest values in a set of data is applicable to specific skewed distributions with varying means and standard deviations. Earlier Rhiel provided values for d(n), the standardized mean range, and a(n), an adjustment for bias in the range estimator of micro. These values are used in estimating the coefficient of variation from the range for skewed distributions. The d(n) and an values were specified for specific skewed distributions with a fixed mean and standard deviation. In this proof it is shown that the d(n) and an values are applicable for the specific skewed distributions when the mean and standard deviation can take on differing values. This will give the researcher confidence in using this statistic for skewed distributions regardless of the mean and standard deviation.

  13. 2 CFR 25.115 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Deviations. 25.115 Section 25.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS Reserved UNIVERSAL IDENTIFIER AND CENTRAL CONTRACTOR...

  14. 2 CFR 25.115 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 2 Grants and Agreements 1 2013-01-01 2013-01-01 false Deviations. 25.115 Section 25.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS PRE-AWARD RESPONSIBILITIES UNIVERSAL IDENTIFIER AND CENTRAL...

  15. 2 CFR 25.115 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 2 Grants and Agreements 1 2012-01-01 2012-01-01 false Deviations. 25.115 Section 25.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS PRE-AWARD RESPONSIBILITIES UNIVERSAL IDENTIFIER AND CENTRAL...

  16. 2 CFR 25.115 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 2 Grants and Agreements 1 2011-01-01 2011-01-01 false Deviations. 25.115 Section 25.115 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements OFFICE OF MANAGEMENT AND BUDGET GOVERNMENTWIDE GUIDANCE FOR GRANTS AND AGREEMENTS Pre-award responsibilities UNIVERSAL IDENTIFIER AND CENTRAL...

  17. Influence of asymmetrical drawing radius deviation in micro deep drawing

    NASA Astrophysics Data System (ADS)

    Heinrich, L.; Kobayashi, H.; Shimizu, T.; Yang, M.; Vollertsen, F.

    2017-09-01

    Nowadays, an increasing demand for small metal parts in electronic and automotive industries can be observed. Deep drawing is a well-suited technology for the production of such parts due to its excellent qualities for mass production. However, the downscaling of the forming process leads to new challenges in tooling and process design, such as high relative deviation of tool geometry or blank displacement compared to the macro scale. FEM simulation has been a widely-used tool to investigate the influence of symmetrical process deviations as for instance a global variance of the drawing radius. This study shows a different approach that allows to determine the impact of asymmetrical process deviations on micro deep drawing. In this particular case the impact of an asymmetrical drawing radius deviation and blank displacement on cup geometry deviation was investigated for different drawing ratios by experiments and FEM simulation. It was found that both variations result in an increasing cup height deviation. Nevertheless, with increasing drawing ratio a constant drawing radius deviation has an increasing impact, while blank displacement results in a decreasing offset of the cups geometry. This is explained by different mechanisms that result in an uneven cup geometry. While blank displacement leads to material surplus on one side of the cup, an unsymmetrical radius deviation on the other hand generates uneven stretching of the cups wall. This is intensified for higher drawing ratios. It can be concluded that the effect of uneven radius geometry proves to be of major importance for the production of accurately shaped micro cups and cannot be compensated by intentional blank displacement.

  18. Refraction in Terms of the Deviation of the Light.

    ERIC Educational Resources Information Center

    Goldberg, Fred M.

    1985-01-01

    Discusses refraction in terms of the deviation of light. Points out that in physics courses where very little mathematics is used, it might be more suitable to describe refraction entirely in terms of the deviation, rather than by introducing Snell's law. (DH)

  19. Developmental Dyslexia, Neurolinguistic Theory and Deviations in Brain Morphology.

    ERIC Educational Resources Information Center

    Hynd, George W.; And Others

    1991-01-01

    Reviews computer tomography and magnetic resonance imaging studies examining deviations in brain morphology. Discusses methodological and technical issues. Concludes that dyslexics show variations in specific brain regions. Suggests that neuroimaging procedures appear to provide direct evidence supporting the importance of deviations in normal…

  20. ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation.

    PubMed

    Loewe, Axel; Schulze, Walther H W; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar

    2015-01-01

    In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.

  1. Tree morphologic plasticity explains deviation from metabolic scaling theory in semi-arid conifer forests, southwestern USA

    Treesearch

    Tyson L. Swetnam; Christopher D. O' Connor; Ann M. Lynch

    2016-01-01

    A significant concern about Metabolic Scaling Theory (MST) in real forests relates to consistent differences between the values of power law scaling exponents of tree primary size measures used to estimate mass and those predicted by MST. Here we consider why observed scaling exponents for diameter and height relationships deviate from MST predictions across...

  2. Preoperative grading of supratentorial gliomas using high or standard b-value diffusion-weighted MR imaging at 3T.

    PubMed

    Cihangiroglu, M M; Ozturk-Isik, E; Firat, Z; Kilickesmez, O; Ulug, A M; Ture, U

    2017-03-01

    The goal of this study was to compare diffusion-weighted magnetic resonance imaging (DW-MRI) using high b-value (b=3000s/mm 2 ) to DW-MRI using standard b-value (b=1000s/mm 2 ) in the preoperative grading of supratentorial gliomas. Fifty-three patients with glioma had brain DW-MRI at 3T using two different b-values (b=1000s/mm 2 and b=3000s/mm 2 ). There were 35 men and 18 women with a mean age of 40.5±17.1 years (range: 18-79 years). Mean, minimum, maximum, and range of apparent diffusion coefficient (ADC) values for solid tumor ROIs (ADC mean , ADC min , ADC max , and ADC diff ), and the normalized ADC (ADC ratio ) were calculated. A Kruskal-Wallis statistic with Bonferroni correction for multiple comparisons was applied to detect significant ADC parameter differences between tumor grades by including or excluding 19 patients with an oligodendroglioma. Receiver operating characteristic curve analysis was conducted to define appropriate cutoff values for grading gliomas. No differences in ADC derived parameters were found between grade II and grade III gliomas. Mean ADC values using standard b-value were 1.17±0.27×10 -3 mm 2 /s [range: 0.63-1.61], 1.05±0.22×10 -3 mm 2 /s [range: 0.73-1.33], and 0.86±0.23×10 -3 mm 2 /s [range: 0.52-1.46] for grades II, III and IV gliomas, respectively. Using high b-value, mean ADC values were 0.89±0.24×10 -3 mm 2 /s [range: 0.42-1.25], 0.82±0.20×10 -3 mm 2 /s [range: 0.56-1.10], and 0.59±0.17×10 -3 mm 2 /s [range: 0.40-1.01] for grades II, III and IV gliomas, respectively. ADC mean , ADC ratio , ADC max , and ADC min were different between grade II and grade IV gliomas at both standard and high b-values. Differences in ADC mean , ADC max , and ADC diff were found between grade III and grade IV only using high b-value. ADC parameters derived from DW-MRI using a high b-value allows a better differential diagnosis of gliomas, especially for differentiating grades III and IV, than those derived from DW-MRI using a standard

  3. Image Format Conversion to DICOM and Lookup Table Conversion to Presentation Value of the Japanese Society of Radiological Technology (JSRT) Standard Digital Image Database.

    PubMed

    Yanagita, Satoshi; Imahana, Masato; Suwa, Kazuaki; Sugimura, Hitomi; Nishiki, Masayuki

    2016-01-01

    Japanese Society of Radiological Technology (JSRT) standard digital image database contains many useful cases of chest X-ray images, and has been used in many state-of-the-art researches. However, the pixel values of all the images are simply digitized as relative density values by utilizing a scanned film digitizer. As a result, the pixel values are completely different from the standardized display system input value of digital imaging and communications in medicine (DICOM), called presentation value (P-value), which can maintain a visual consistency when observing images using different display luminance. Therefore, we converted all the images from JSRT standard digital image database to DICOM format followed by the conversion of the pixel values to P-value using an original program developed by ourselves. Consequently, JSRT standard digital image database has been modified so that the visual consistency of images is maintained among different luminance displays.

  4. Mean-deviation analysis in the theory of choice.

    PubMed

    Grechuk, Bogdan; Molyboha, Anton; Zabarankin, Michael

    2012-08-01

    Mean-deviation analysis, along with the existing theories of coherent risk measures and dual utility, is examined in the context of the theory of choice under uncertainty, which studies rational preference relations for random outcomes based on different sets of axioms such as transitivity, monotonicity, continuity, etc. An axiomatic foundation of the theory of coherent risk measures is obtained as a relaxation of the axioms of the dual utility theory, and a further relaxation of the axioms are shown to lead to the mean-deviation analysis. Paradoxes arising from the sets of axioms corresponding to these theories and their possible resolutions are discussed, and application of the mean-deviation analysis to optimal risk sharing and portfolio selection in the context of rational choice is considered. © 2012 Society for Risk Analysis.

  5. Recommended Values of the Fundamental Physical Constants: A Status Report

    PubMed Central

    Taylor, Barry N.; Cohen, E. Richard

    1990-01-01

    We summarize the principal advances made in the fundamental physical constants field since the completion of the 1986 CODATA least-squares adjustment of the constants and discuss their implications for both the 1986 set of recommended values and the next least-squares adjustment. In general, the new results lead to values of the constants with uncertainties 5 to 7 times smaller than the uncertainties assigned the 1986 values. However, the changes in the values themselves are less than twice the 1986 assigned one-standard-deviation uncertainties and thus are not highly significant. Although much new data has become available since 1986, three new results dominate the analysis: a value of the Planck constant obtained from a realization of the watt; a value of the fine-structure constant obtained from the magnetic moment anomaly of the electron; and a value of the molar gas constant obtained from the speed of sound in argon. Because of their dominant role in determining the values and uncertainties of many of the constants, it is highly desirable that additional results of comparable uncertainty that corroborate these three data items be obtained before the next adjustment is carried out. Until then, the 1986 CODATA set of recommended values will remain the set of choice. PMID:28179787

  6. Stone heterogeneity index as the standard deviation of Hounsfield units: A novel predictor for shock-wave lithotripsy outcomes in ureter calculi

    PubMed Central

    Lee, Joo Yong; Kim, Jae Heon; Kang, Dong Hyuk; Chung, Doo Yong; Lee, Dae Hun; Do Jung, Hae; Kwon, Jong Kyou; Cho, Kang Su

    2016-01-01

    We investigated whether stone heterogeneity index (SHI), which a proxy of such variations, was defined as the standard deviation of a Hounsfield unit (HU) on non-contrast computed tomography (NCCT), can be a novel predictor for shock-wave lithotripsy (SWL) outcomes in patients with ureteral stones. Medical records were obtained from the consecutive database of 1,519 patients who underwent the first session of SWL for urinary stones between 2005 and 2013. Ultimately, 604 patients with radiopaque ureteral stones were eligible for this study. Stone related variables including stone size, mean stone density (MSD), skin-to-stone distance, and SHI were obtained on NCCT. Patients were classified into the low and high SHI groups using mean SHI and compared. One-session success rate in the high SHI group was better than in the low SHI group (74.3% vs. 63.9%, P = 0.008). Multivariate logistic regression analyses revealed that smaller stone size (OR 0.889, 95% CI: 0.841–0.937, P < 0.001), lower MSD (OR 0.995, 95% CI: 0.994–0.996, P < 0.001), and higher SHI (OR 1.011, 95% CI: 1.008–1.014, P < 0.001) were independent predictors of one-session success. The radiologic heterogeneity of urinary stones or SHI was an independent predictor for SWL success in patients with ureteral calculi and a useful clinical parameter for stone fragility. PMID:27035621

  7. 48 CFR 570.704 - Deviations to provisions and clauses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Deviations to provisions and clauses. 570.704 Section 570.704 Federal Acquisition Regulations System GENERAL SERVICES... contracting officer also needs an approved deviation to modify the language of a provision or clause mandated...

  8. 48 CFR 570.704 - Deviations to provisions and clauses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Deviations to provisions and clauses. 570.704 Section 570.704 Federal Acquisition Regulations System GENERAL SERVICES... contracting officer also needs an approved deviation to modify the language of a provision or clause mandated...

  9. 48 CFR 570.704 - Deviations to provisions and clauses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Deviations to provisions and clauses. 570.704 Section 570.704 Federal Acquisition Regulations System GENERAL SERVICES... contracting officer also needs an approved deviation to modify the language of a provision or clause mandated...

  10. 48 CFR 570.704 - Deviations to provisions and clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Deviations to provisions and clauses. 570.704 Section 570.704 Federal Acquisition Regulations System GENERAL SERVICES... contracting officer also needs an approved deviation to modify the language of a provision or clause mandated...

  11. SU-E-I-27: Establishing Target Exposure Index Values for Computed Radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, N; Tchou, P; Belcher, K

    2014-06-01

    Purpose: To develop a standard set of target exposure index (TEI) values to be applied to Agfa Computed Radiography (CR) readers in accordance with International Electrotechnical Committee 62494-1 (ed. 1.0). Methods: A large data cohort was collected from six USAF Medical Treatment Facilities that exclusively use Agfa CR Readers. Dose monitoring statistics were collected from each reader. The data was analyzed based on anatomic region, view, and processing speed class. The Agfa specific exposure metric, logarithmic mean (LGM), was converted to exposure index (EI) for each data set. The optimum TEI value was determined by minimizing the number of studiesmore » that fell outside the acceptable deviation index (DI) range of +/− 2 for phototimed techniques or a range of +/−3 for fixed techniques. An anthropomorphic radiographic phantom was used to corroborate the TEI recommendations. Images were acquired of several anatomic regions and views using standard techniques. The images were then evaluated by two radiologists as either acceptable or unacceptable. The acceptable image with the lowest exposure and EI value was compared to the recommended TEI values using a passing DI range. Results: Target EI values were determined for a comprehensive list of anatomic regions and views. Conclusion: Target EI values must be established on each CR unit in order to provide a positive feedback system for the technologist. This system will serve as a mechanism to prevent under or overexposures of patients. The TEI recommendations are a first attempt at a large scale process improvement with the goal of setting reasonable and standardized TEI values. The implementation and effectiveness of the recommended TEI values should be monitored and adjustments made as necessary.« less

  12. Importance sampling large deviations in nonequilibrium steady states. I.

    PubMed

    Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T

    2018-03-28

    Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.

  13. Importance sampling large deviations in nonequilibrium steady states. I

    NASA Astrophysics Data System (ADS)

    Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T.

    2018-03-01

    Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.

  14. Standard deviation of carotid young's modulus and presence or absence of plaque improves prediction of coronary heart disease risk.

    PubMed

    Niu, Lili; Zhang, Yanling; Qian, Ming; Xiao, Yang; Meng, Long; Zheng, Rongqin; Zheng, Hairong

    2017-11-01

    The stiffness of large arteries and the presence or absence of plaque are associated with coronary heart disease (CHD). Because arterial walls are biologically heterogeneous, the standard deviation of Young's modulus (YM-std) of the large arteries may better predict coronary atherosclerosis. However, the role of YM-std in the occurrence of coronary events has not been addressed so far. Therefore, this study investigated whether the carotid YM-std and the presence or absence of plaque improved CHD risk prediction. One hundred and three patients with CHD (age 66 ± 11 years) and 107 patients at high risk of atherosclerosis (age 61 ± 7 years) were recruited. Carotid YM was measured by the vessel texture matching method, and YM-std was calculated. Carotid intima-media thickness was measured by the MyLab 90 ultrasound Platform employed dedicated software RF-tracking technology. In logistic regression analysis, YM-std (OR = 1·010; 95% CI = 1·003-1·016), carotid plaque (OR = 16·759; 95% CI = 3·719-75·533) and YM-std plus plaque (OR = 0·989; 95% CI = 0·981-0·997) were independent predictors of CHD. The traditional risk factors (TRF) plus YM-std plus plaque model showed a significant improvement in area under the receiver-operating characteristic curve (AUC), which increased from 0·717 (TRF only) to 0·777 (95% CI for the difference in adjusted AUC: 0·010-0·110). Carotid YM-std is a powerful independent predictor of CHD. Adding plaque and YM-std to TRF improves CHD risk prediction. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  15. Erratic tacrolimus exposure, assessed using the standard deviation of trough blood levels, predicts chronic lung allograft dysfunction and survival.

    PubMed

    Gallagher, Harry M; Sarwar, Ghulam; Tse, Tracy; Sladden, Timothy M; Hii, Esmond; Yerkovich, Stephanie T; Hopkins, Peter M; Chambers, Daniel C

    2015-11-01

    Erratic tacrolimus blood levels are associated with liver and kidney graft failure. We hypothesized that erratic tacrolimus exposure would similarly compromise lung transplant outcomes. This study assessed the effect of tacrolimus mean and standard deviation (SD) levels on the risk of chronic lung allograft dysfunction (CLAD) and death after lung transplantation. We retrospectively reviewed 110 lung transplant recipients who received tacrolimus-based immunosuppression. Cox proportional hazard modeling was used to investigate the effect of tacrolimus mean and SD levels on survival and CLAD. At census, 48 patients (44%) had developed CLAD and 37 (34%) had died. Tacrolimus SD was highest for the first 6 post-transplant months (median, 4.01; interquartile range [IQR], 3.04-4.98 months) before stabilizing at 2.84 μg/liter (IQR, 2.16-4.13 μg/liter) between 6 and 12 months. The SD then remained the same (median, 2.85; IQR, 2.00-3.77 μg/liter) between 12 and 24 months. A high mean tacrolimus level 6 to 12 months post-transplant independently reduced the risk of CLAD (hazard ratio [HR], 0.74; 95% confidence interval [CI], 0.63-0.86; p < 0.001) but not death (HR, 0.96; 95% CI, 0.83-1.12; p = 0.65). In contrast, a high tacrolimus SD between 6 and 12 months independently increased the risk of CLAD (HR, 1.46; 95% CI, 1.23-1.73; p < 0.001) and death (HR, 1.27; 95% CI, 1.08-1.51; p = 0.005). Erratic tacrolimus levels are a risk factor for poor lung transplant outcomes. Identifying and modifying factors that contribute to this variability may significantly improve outcomes. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  16. Estimation of Gutenberg-Richter b-value using instrumental earthquake catalog from the southern Korean Peninsula

    NASA Astrophysics Data System (ADS)

    Lee, H.; Sheen, D.; Kim, S.

    2013-12-01

    The b-value in Gutenberg-Richter relation is an important parameter widely used not only in the interpretation of regional tectonic structure but in the seismic hazard analysis. In this study, we tested four methods for estimating the stable b-value in a small number of events using Monte-Carlo method. One is the Least-Squares method (LSM) which minimizes the observation error. Others are based on the Maximum Likelihood method (MLM) which maximizes the likelihood function: Utsu's (1965) method for continuous magnitudes and an infinite maximum magnitude, Page's (1968) for continuous magnitudes and a finite maximum magnitude, and Weichert's (1980) for interval magnitude and a finite maximum magnitude. A synthetic parent population of the earthquake catalog of million events from magnitude 2.0 to 7.0 with interval of 0.1 was generated for the Monte-Carlo simulation. The sample, the number of which was increased from 25 to 1000, was extracted from the parent population randomly. The resampling procedure was applied 1000 times with different random seed numbers. The mean and the standard deviation of the b-value were estimated for each sample group that has the same number of samples. As expected, the more samples were used, the more stable b-value was obtained. However, in a small number of events, the LSM gave generally low b-value with a large standard deviation while other MLMs gave more accurate and stable values. It was found that Utsu (1965) gives the most accurate and stable b-value even in a small number of events. It was also found that the selection of the minimum magnitude could be critical for estimating the correct b-value for Utsu's (1965) method and Page's (1968) if magnitudes were binned into an interval. Therefore, we applied Utsu (1965) to estimate the b-value using two instrumental earthquake catalogs, which have events occurred around the southern part of the Korean Peninsula from 1978 to 2011. By a careful choice of the minimum magnitude, the b-values

  17. Clinical Implications of Septal Deviation in Lateralized Olfaction

    PubMed Central

    Choi, Yoon-Seok; Ryu, Yoon-Jong; Rhee, Jihye; Seok, Jungirl; Han, Sungjun; Jin, Hong Ryul; Kim, Dae Woo

    2016-01-01

    Objectives Results of butanol threshold tests (BTTs) have shown that birhinal olfaction tends to converge toward monorhinal olfaction of the dominant nostril. However, birhinal olfaction may also be worse than dominant-side monorhinal olfaction. The goal of our study was to investigate the effect of deviated nasal septum on birhinal olfaction in patients with lateralized olfaction and to examine the effect of septoplasty in these patients. Methods A retrospective study with planned data collection was conducted in 518 patients who underwent BTTs. Lateralized olfaction was defined as monorhinal BTT scores that differed by >2 between sides. Underestimated birhinal olfaction was defined as a birhinal BTT score >2 lower than the dominant nostril monorhinal BTT score. Patients with lateralized olfaction were divided into 2 groups: group 1, underestimated birhinal olfaction; and group 2, without underestimated birhinal olfaction. Results Among 518 patients, 112 with lateralized olfaction were enrolled in this study. Group 1 included 23 patients (20.5%) and group 2 included 89 patients (79.5%). The severity of septal deviation (ratio of the distance of narrower side to wider side) did not differ between the 2 groups. Septal deviation to the dominant nostril was more common in group 1 than group 2 (73.9% vs. 37.6%; P=0.002). Five patients with septal deviation to the dominant nostril with underestimated birhinal olfaction underwent septoplasty. Improved lateralized olfaction occurred in all 5 patients postoperatively (P=0.041). Conclusion Septal deviation of the dominant nostril in patients with lateralized olfaction is associated with underestimated birhinal olfaction. Septoplasty may improve olfaction by increasing airflow in the dominant olfactory side. PMID:26976025

  18. A Method for the Automatic Exposure Control in Pediatric Abdominal CT: Application to the Standard Deviation Value and Tube Current Methods by Using Patient's Age and Body Size.

    PubMed

    Furuya, Ken; Akiyama, Shinji; Nambu, Atushi; Suzuki, Yutaka; Hasebe, Yuusuke

    2017-01-01

    We aimed to apply the pediatric abdominal CT protocol of Donnelly et al. in the United States to the pediatric abdominal CT-AEC. Examining CT images of 100 children, we found that the sectional area of the hepatic portal region (y) was strongly correlated with the body weight (x) as follows: y=7.14x + 84.39 (correlation coefficient=0.9574). We scanned an elliptical cone phantom that simulates the human body using a pediatric abdominal CT scanning method of Donnelly et al. in, and measured SD values. We further scanned the same phantom under the settings for adult CT-AEC scan and obtained the relationship between the sectional areas (y) and the SD values. Using these results, we obtained the following preset noise factors for CT-AEC at each body weight range: 6.90 at 4.5-8.9 kg, 8.40 at 9.0-17.9 kg, 8.68 at 18.0-26.9 kg, 9.89 at 27.0-35.9 kg, 12.22 at 36.0-45.0 kg, 13.52 at 45.1-70.0 kg, 15.29 at more than 70 kg. From the relation between age, weight and the distance of liver and tuber ischiadicum of 500 children, we obtained the CTDI vol values and DLP values under the scanning protocol of Donnelly et al. Almost all of DRL from these values turned out to be smaller than the DRL data of IAEA and various countries. Thus, by setting the maximum current values of CT-AEC to be the Donnelly et al.'s age-wise current values, and using our weight-wise noise factors, we think we can perform pediatric abdominal CT-AEC scans that are consistent with the same radiation safety and the image quality as those proposed by Donnelly et al.

  19. Relevance of methods and standards for the assessment of measurement system performance in a High-Value Manufacturing Industry

    NASA Astrophysics Data System (ADS)

    Loftus, Pete; Giudice, Seb

    2014-08-01

    Measurements underpin the engineering decisions that allow products to be designed, manufactured, operated, and maintained. Therefore, the quality of measured data needs to be systematically assured to allow decision makers to proceed with confidence. The use of standards is one way of achieving this. This paper explores the relevance of international documentary standards to the assessment of measurement system capability in High Value Manufacturing (HVM) Industry. An internal measurement standard is presented which supplements these standards and recommendations are made for a cohesive effort to develop the international standards to provide consistency in such industrial applications.

  20. T-wave axis deviation, metabolic syndrome and estimated cardiovascular risk--in men and women of the MOLI-SANI study.

    PubMed

    Rago, Livia; Di Castelnuovo, Augusto; Assanelli, Deodato; Badilini, Fabio; Vaglio, Martino; Gianfagna, Francesco; Salvetti, Massimo; Zito, Francesco; Alessandrini, Francesco; Donati, Maria Benedetta; de Gaetano, Giovanni; Iacoviello, Licia

    2013-02-01

    We aimed at investigating the association between T-wave axis deviation, metabolic syndrome (MetS), its components and estimated risk of cardiovascular disease (CVD) at 10 years in an adult Italian population. 11,143 women (54 ± 11 years) and 9742 men (55 ± 11 years) were analyzed from the Moli-sani cohort, randomly recruited from the general population. MetS was defined using the ATPIII criteria. T-wave axis deviation was measured from the standard 12-lead resting electrocardiogram. CVD risk in ten years was estimated by the CUORE score. 29% of men and 27% of women with MetS showed borderline or abnormal T-wave as compared to 24% and 17% without MetS (p < 0.0001 for both genders). Among components of MetS, elevated waist and blood pressure were strongly associated with T-wave axis deviation, whereas glucose, HDL and triglycerides were only marginally. The odds of having borderline or abnormal T-wave axis deviation in multivariable regression analysis, was 1.38 (95% CI:1.25-1.53) in MetS men and 1.68 (95% CI:1.51-1.87) in MetS women compared to those without. Further adjustment for MetS components completely abolished the associations. Abnormal T-wave axis deviation was associated with an increased risk of CVD in 10 years in men (OR = 4.4; 95% CI:1.10-17.9). T-wave axis deviation is strongly associated with components of the MetS, in particular high waist circumference and blood pressure and with an increased CVD risk, particularly in men. ECG monitoring to identify T-wave axis deviation in obese, hypertensive or MetS subjects can be an early indicator of vascular disease and help in reducing cardiac events. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Professional values and career choice of nursing students.

    PubMed

    Alkaya, Sultan Ayaz; Yaman, Şengül; Simones, Joyce

    2018-03-01

    Professional values are abstract and general behavioral principles that provide basic standards to judge aims and actions, and these principles are formed by strong emotional loyalty of members of the profession. Research was conducted to compare the career choice and professional values of nursing students at two universities in the upper Midwest of the United States and in the middle of Turkey. A descriptive and comparative design was used. The participants of the study were comprised nursing students from a university in the upper Midwest of United States and a university in the middle of Turkey. The sample consisted of 728 students in all grades. Data were collected by a questionnaire, The Nurses Professional Values Scale-Revised and Vocational Choices in Entering Nursing Scale. Number, percentage distribution, mean, standard deviation, t test, and one-way variance analysis were used in the analysis of data. Ethical considerations: Ethical approval was obtained from the Ethics Commission. Informed consent was received from the students. The students' mean age for American students was 24.3 ± 5.6 years, while the mean age for Turkish students was 19.8 ± 1.7 years. Mean score of American students on The Vocational Congruency (a subgroup of the Vocational Choices in Entering Nursing Scale) was 38.5 ± 5.9 and Turkish students was 29.6 ± 8.9 (p < 0.05). Mean score of American students on The Nurses Professional Values Scale-Revised was 109.2 ± 12.3 and that of Turkish students was 101.6 ± 17.0. This study concluded that the majority of nursing students had high professional values, and when students' scores were compared, American students had higher professional values, and in career choice, they considered primarily fitness of the profession to themselves and their goals, while Turkish students primarily thought of their living conditions.

  2. Enantiomer fractions of polychlorinated biphenyls in three selected Standard Reference Materials.

    PubMed

    Morrissey, Joshua A; Bleackley, Derek S; Warner, Nicholas A; Wong, Charles S

    2007-01-01

    The enantiomer composition of six chiral polychlorinated biphenyls (PCBs) were measured in three different certified Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST): SRM 1946 (Lake Superior fish tissue), SRM 1939a (PCB Congeners in Hudson River Sediment), and SRM 2978 (organic contaminants in mussel tissue--Raritan Bay, New Jersey) to aid in quality assurance/quality control methodologies in the study of chiral pollutants in sediments and biota. Enantiomer fractions (EFs) of PCBs 91, 95, 136, 149, 174, and 183 were measured using a suite of chiral columns by gas chromatography/mass spectrometry. Concentrations of target analytes were in agreement with certified values. Target analyte EFs in reference materials were measured precisely (<2% relative standard deviation), indicating the utility of SRM in quality assurance/control methodologies for analyses of chiral compounds in environmental samples. Measured EFs were also in agreement with previously published analyses of similar samples, indicating that similar enantioselective processes were taking place in these environmental matrices.

  3. TU-FG-209-08: Distribution of the Deviation Index (DI) in Digital Radiography Practices Across the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A; Shepard, S; Dave, J

    Purpose: To characterize the distribution of the deviation index (DI) in digital radiography practices across the United States. Methods: DI data was obtained from 10 collaborating institutions in the United States between 2012 and 2015. Each institution complied with the requirements of the Institutional Review Board at their site. DI data from radiographs of the body parts chest, abdomen, pelvis and extremity were analyzed for anteroposterior, posteroanterior, lateral, and decubitus views. The DI data was analyzed both in aggregate and stratified by exposure control method, image receptor technology, patient age, and participating site for each body part and view. Themore » number of exposures with DI falling within previously published control limits for DI and descriptive statistics were calculated. Results: DI data from 505,930 radiographic exposures was analyzed. The number of exposures with DI falling within published control limits for DI varied from 10 to 20% for adult patients and 10 to 23% for pediatric patients for different body parts and views. Mean DI values averaged over other parameters for radiographs of the abdomen, chest, pelvis, and extremities ranged from 0.3 to 1.0, −0.6 to 0.5, 0.8, and −0.9 to 0.5 for the different adult views and ranged from −1.6 to −0.1, −0.3 to 0.5, −0.1, −0.2 to 1.4 for the different pediatric views, respectively (DI data was solicited only for anteroposterior view of pelvis). Standard deviation values of DI from individual sites ranged from 1.3 to 3.6 and 1.3 to 3.0 for the different adult and pediatric views, respectively. Also of interest was that target exposure indicators varied by up to a factor of 6 between sites for certain body parts and views. Conclusion: Previously published DI control limits do not reflect the state of clinical practice in digital radiography. Mean DI and target exposure indicators are targets for quality improvement efforts in radiography.« less

  4. Triangular Resection of the Upper Lateral Cartilage for Middle Vault Deviation.

    PubMed

    Ryu, Gwanghui; Seo, Min Young; Lee, Kyung Eun; Hong, Sang Duk; Chung, Seung-Kyu; Dhong, Hun-Jong; Kim, Hyo Yeol

    2018-06-02

    Middle vault deviation has a significant effect on the aesthetic and functional aspects of the nose, and its management continues to be a challenge. Spreader graft and its modification techniques have been focused, but there has been scarce consideration for removing surplus portion and balancing the upper lateral cartilage (ULC). This study aimed to report the newly invented triangular-shaped resection technique ("triangular resection") of the ULC and to evaluate its efficacy for correcting middle vault deviation. A retrospective study included 17 consecutive patients who presented with middle vault deviation and underwent septorhinoplasty by using triangular resection at a tertiary academic hospital from February 2014 and March 2016. Their outcomes were evaluated pre- and postoperatively including medical photographs, acoustic rhinometry and subjective nasal obstruction using a 7-point Likert scale. The immediate outcomes were evaluated around 1 month after surgery, and long-term outcomes were available in 12 patients; the mean follow-up period was 9.1 months. Nasal tip deviation angle was reduced from 5.66º to 2.37º immediately (P<0.001). Middle vault deviation also improved from 169.50º to 177.24º (P<0.001). Long-term results were 2.49º (P=0.015) for nasal tip deviation and 178.68º (P=0.002) for middle vault deviation. The aesthetic outcome involved a complete correction in eight patients (47.1%), a minimally visible deviation in seven patients (41.2%) and a remaining residual deviation in two patients (11.8%). Pre- and postoperative minimal cross-sectional areas (summation of the right and left sides) were 0.86 and 1.07, respectively (P=0.021). Fifteen patients answered about their nasal obstruction symptoms and the median symptom score had alleviated from 6.0 to 3.0 (P=0.004). Triangular resection of the ULC is a simple and effective method for correcting middle vault deviation and balancing the ULCs without complications as internal nasal valve

  5. 45 CFR 63.19 - Budget revisions and minor deviations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Budget revisions and minor deviations. 63.19 Section 63.19 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION GRANT PROGRAMS... Budget revisions and minor deviations. Pursuant to § 74.102(d) of this title, paragraphs (b)(3) and (b)(4...

  6. 45 CFR 63.19 - Budget revisions and minor deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Budget revisions and minor deviations. 63.19 Section 63.19 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION GRANT PROGRAMS... Budget revisions and minor deviations. Pursuant to § 74.102(d) of this title, paragraphs (b)(3) and (b)(4...

  7. Neoclassical canons of facial beauty: Do we see the deviations?

    PubMed

    Pavlic, Andrej; Trinajstic Zrinski, Magda; Katic, Visnja; Spalj, Stjepan

    2017-05-01

    To explore the presence of neoclassical canons of facial beauty among young people in Croatia and to question possible psychosocial repercussions occurring in those who demonstrate deviations in relation to canons. The study was cross-sectional and the sample included 249 subjects (60% female) aged 12-39 (median 20). Their en face and profile photographs were taken in Natural Head Position. Photogrammetry included analysis of nine neoclassical canons of facial beauty originating from the Renaissance. Psychosocial issues were assessed using the Self-Esteem Scale, Big Five Inventory and three domains of Orthognathic Quality of Life Questionnaire. Significant deviations from neoclassical facial beauty canons were observed in 55-65% of adolescents and young adults. Gender and age showed no relation to deviations. The deviations from canons that influenced the quality of life were mainly those related to vertical facial proportions and demonstrated increased facial aesthetics concern and social impact, and higher self-reported treatment need (p < 0.05). Deviations from canons were not related to self-esteem but a decrease in openness, agreeableness and neuroticism was observed. Neoclassical canons were not valid for the majority of adolescents and young adults in Croatia. Only deviations from some canons appear to provoke mild psychosocial repercussions. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Scaling theory of temporal correlations and size-dependent fluctuations in the traded value of stocks

    NASA Astrophysics Data System (ADS)

    Eisler, Zoltán; Kertész, János

    2006-04-01

    Records of the traded value fi of stocks display fluctuation scaling, a proportionality between the standard deviation σi and the average ⟨fi⟩ : σi∝⟨fi⟩α , with a strong time scale dependence α(Δt) . The nontrivial (i.e., neither 0.5 nor 1) value of α may have different origins and provides information about the microscopic dynamics. We present a set of stylized facts and then show their connection to such behavior. The functional form α(Δt) originates from two aspects of the dynamics: Stocks of larger companies both tend to be traded in larger packages and also display stronger correlations of traded value. The results are integrated into a general framework that can be applied to a wide range of complex systems.

  9. Successful treatment of open jaw and jaw deviation dystonia with botulinum toxin using a simple intraoral approach.

    PubMed

    Moscovich, Mariana; Chen, Zhongxing Peng; Rodriguez, Ramon

    2015-03-01

    Oromandibular dystonia (OMD) is a focal dystonia that involves the mouth, jaw, and/or tongue. It can be classified as idiopathic, tardive dystonia or secondary to other neurological disorders and subdivided into jaw opening, jaw closing, jaw deviation and lip pursing. The muscles involved in jaw opening dystonia are usually the digastrics and lateral pterygoids. It is known that the lateral pterygoids may be approached both internally and externally. The external approach is the most common; however neurologists experienced in treating patients with botulinum toxin can safely and with no extra cost perform the intraoral procedure. We report our experience in the treatment of jaw opening and jaw deviation dystonia using the intraoral injection approach. Eight patients were selected from the University of Florida with a clinical diagnosis of open jaw/jaw deviation dystonia. All of them were injected with onabotulinum toxin A using the internal approach and the clinical global impression scale was applied. The mean age of the patients was 67 (standard deviation [SD] 10.2) years, with a disease duration of 10.2 (SD 7.7) years and the mean distance they traveled to our institution was 448 km (278 miles). After treatment, six patients scored as very much improved in the clinical global impression scale and two patients scored as much improved. Only one patient reported an adverse event of nasal speech following one of the injections that improved after 4 weeks. Botulinum toxin injections for open jaw/jaw deviation dystonia can be safely performed with the intraoral approach without the need of special devices other than electromyography. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Serum Oxidative Stress Levels in Patients with Nasal Septal Deviation

    PubMed Central

    Ekinci, Adnan; Karataş, Duran; Yetiş, Abdurrahman; Demir, Emre; Özcan, Müge

    2017-01-01

    Objective Comparison of the total oxidant status (TOS), total antioxidant status (TAS) and paraoxonase (PON1) serum levels in patients with nasal septum deviation (NSD) and healthy subjects. Methods The TAS, TOS, and PON1 serum levels of 47 patients with NSD (mean age 35.3) and 50 healthy subjects (mean age 37.8) were compared in this study. Results We found significantly higher TAS levels in the control group (p<0.001). The mean TAS value was 1.196 mmoL/L in the control group, whereas it was 1.046 mmoL/L in the NSD group. On the other hand, TOS was significantly higher in the NSD group (p<0.001). We found that the mean TOS value was 6.600 mmoL/L in the control group, and 20.194 mmoL/L in the NSD group. The NSD and control groups had similar PON1 levels (p=0.446). The mean PON1 value was 279.64 U/L in the control group, and 324.21 U/L in the NSD group. Conclusion We detected higher TOS and lower TAS levels in patients with NSD compared to healthy subjects. These results indicate that patients with NSD are exposed to oxidative stress. PMID:29392069

  11. Exact Large-Deviation Statistics for a Nonequilibrium Quantum Spin Chain

    NASA Astrophysics Data System (ADS)

    Žnidarič, Marko

    2014-01-01

    We consider a one-dimensional XX spin chain in a nonequilibrium setting with a Lindblad-type boundary driving. By calculating large-deviation rate function in the thermodynamic limit, a generalization of free energy to a nonequilibrium setting, we obtain a complete distribution of current, including closed expressions for lower-order cumulants. We also identify two phase-transition-like behaviors in either the thermodynamic limit, at which the current probability distribution becomes discontinuous, or at maximal driving, when the range of possible current values changes discontinuously. In the thermodynamic limit the current has a finite upper and lower bound. We also explicitly confirm nonequilibrium fluctuation relation and show that the current distribution is the same under mapping of the coupling strength Γ→1/Γ.

  12. A hybrid method with deviational particles for spatial inhomogeneous plasma

    NASA Astrophysics Data System (ADS)

    Yan, Bokai

    2016-03-01

    In this work we propose a Hybrid method with Deviational Particles (HDP) for a plasma modeled by the inhomogeneous Vlasov-Poisson-Landau system. We split the distribution into a Maxwellian part evolved by a grid based fluid solver and a deviation part simulated by numerical particles. These particles, named deviational particles, could be both positive and negative. We combine the Monte Carlo method proposed in [31], a Particle in Cell method and a Macro-Micro decomposition method [3] to design an efficient hybrid method. Furthermore, coarse particles are employed to accelerate the simulation. A particle resampling technique on both deviational particles and coarse particles is also investigated and improved. This method is applicable in all regimes and significantly more efficient compared to a PIC-DSMC method near the fluid regime.

  13. Allan deviation computations of a linear frequency synthesizer system using frequency domain techniques

    NASA Technical Reports Server (NTRS)

    Wu, Andy

    1995-01-01

    Allan Deviation computations of linear frequency synthesizer systems have been reported previously using real-time simulations. Even though it takes less time compared with the actual measurement, it is still very time consuming to compute the Allan Deviation for long sample times with the desired confidence level. Also noises, such as flicker phase noise and flicker frequency noise, can not be simulated precisely. The use of frequency domain techniques can overcome these drawbacks. In this paper the system error model of a fictitious linear frequency synthesizer is developed and its performance using a Cesium (Cs) atomic frequency standard (AFS) as a reference is evaluated using frequency domain techniques. For a linear timing system, the power spectral density at the system output can be computed with known system transfer functions and known power spectral densities from the input noise sources. The resulting power spectral density can then be used to compute the Allan Variance at the system output. Sensitivities of the Allan Variance at the system output to each of its independent input noises are obtained, and they are valuable for design trade-off and trouble-shooting.

  14. Radial gradient and radial deviation radiomic features from pre-surgical CT scans are associated with survival among lung adenocarcinoma patients.

    PubMed

    Tunali, Ilke; Stringfield, Olya; Guvenis, Albert; Wang, Hua; Liu, Ying; Balagurunathan, Yoganand; Lambin, Philippe; Gillies, Robert J; Schabath, Matthew B

    2017-11-10

    The goal of this study was to extract features from radial deviation and radial gradient maps which were derived from thoracic CT scans of patients diagnosed with lung adenocarcinoma and assess whether these features are associated with overall survival. We used two independent cohorts from different institutions for training (n= 61) and test (n= 47) and focused our analyses on features that were non-redundant and highly reproducible. To reduce the number of features and covariates into a single parsimonious model, a backward elimination approach was applied. Out of 48 features that were extracted, 31 were eliminated because they were not reproducible or were redundant. We considered 17 features for statistical analysis and identified a final model containing the two most highly informative features that were associated with lung cancer survival. One of the two features, radial deviation outside-border separation standard deviation, was replicated in a test cohort exhibiting a statistically significant association with lung cancer survival (multivariable hazard ratio = 0.40; 95% confidence interval 0.17-0.97). Additionally, we explored the biological underpinnings of these features and found radial gradient and radial deviation image features were significantly associated with semantic radiological features.

  15. Radial gradient and radial deviation radiomic features from pre-surgical CT scans are associated with survival among lung adenocarcinoma patients

    PubMed Central

    Tunali, Ilke; Stringfield, Olya; Guvenis, Albert; Wang, Hua; Liu, Ying; Balagurunathan, Yoganand; Lambin, Philippe; Gillies, Robert J.; Schabath, Matthew B.

    2017-01-01

    The goal of this study was to extract features from radial deviation and radial gradient maps which were derived from thoracic CT scans of patients diagnosed with lung adenocarcinoma and assess whether these features are associated with overall survival. We used two independent cohorts from different institutions for training (n= 61) and test (n= 47) and focused our analyses on features that were non-redundant and highly reproducible. To reduce the number of features and covariates into a single parsimonious model, a backward elimination approach was applied. Out of 48 features that were extracted, 31 were eliminated because they were not reproducible or were redundant. We considered 17 features for statistical analysis and identified a final model containing the two most highly informative features that were associated with lung cancer survival. One of the two features, radial deviation outside-border separation standard deviation, was replicated in a test cohort exhibiting a statistically significant association with lung cancer survival (multivariable hazard ratio = 0.40; 95% confidence interval 0.17-0.97). Additionally, we explored the biological underpinnings of these features and found radial gradient and radial deviation image features were significantly associated with semantic radiological features. PMID:29221183

  16. ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation

    PubMed Central

    Schulze, Walther H. W.; Jiang, Yuan; Wilhelms, Mathias; Luik, Armin; Dössel, Olaf; Seemann, Gunnar

    2015-01-01

    In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold. PMID:26587538

  17. Sub-grain induced crack deviation in multi-crystalline silicon

    NASA Astrophysics Data System (ADS)

    Zhao, Lv; Nelias, Daniel; Bardel, Didier; Wang, Meng; Marie, Benoit

    2017-06-01

    The fracture process in crystalline silicon is dictated by energy dissipation. Here, we show that sub-grains can deviate the crack path from the most energetically favorable ( 111) plane. Albeit a small misorientation across the sub-grain boundary is identified, upon entering into the sub-grain region, the crack either slightly deviates from the ideal ( 111) plane or directly chooses the secondly most favorable ( 110) one. We propose that the deviation is related to the dislocation core in the ( 111) crystal plane, which leads to a discontinuous atom debonding process and consequently a pronounced lattice trapping. In this circumstance, localized crystal defects prevail in the fracture process of silicon, while energetical criterion fails to interpret the crack path.

  18. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  19. Large deviations of a long-time average in the Ehrenfest urn model

    NASA Astrophysics Data System (ADS)

    Meerson, Baruch; Zilber, Pini

    2018-05-01

    Since its inception in 1907, the Ehrenfest urn model (EUM) has served as a test bed of key concepts of statistical mechanics. Here we employ this model to study large deviations of a time-additive quantity. We consider two continuous-time versions of the EUM with K urns and N balls: with and without interactions between the balls in the same urn. We evaluate the probability distribution that the average number of balls in one urn over time T, , takes any specified value aN, where . For long observation time, , a Donsker–Varadhan large deviation principle holds: , where … denote additional parameters of the model. We calculate the rate function exactly by two different methods due to Donsker and Varadhan and compare the exact results with those obtained with a variant of WKB approximation (after Wentzel, Kramers and Brillouin). In the absence of interactions the WKB prediction for is exact for any N. In the presence of interactions the WKB method gives asymptotically exact results for . The WKB method also uncovers the (very simple) time history of the system which dominates the contribution of different time histories to .

  20. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    PubMed

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  1. Effects of expected-value information and display format on recognition of aircraft subsystem abnormalities

    NASA Technical Reports Server (NTRS)

    Palmer, Michael T.; Abbott, Kathy H.

    1994-01-01

    This study identifies improved methods to present system parameter information for detecting abnormal conditions and to identify system status. Two workstation experiments were conducted. The first experiment determined if including expected-value-range information in traditional parameter display formats affected subject performance. The second experiment determined if using a nontraditional parameter display format, which presented relative deviation from expected value, was better than traditional formats with expected-value ranges included. The inclusion of expected-value-range information onto traditional parameter formats was found to have essentially no effect. However, subjective results indicated support for including this information. The nontraditional column deviation parameter display format resulted in significantly fewer errors compared with traditional formats with expected-value-ranges included. In addition, error rates for the column deviation parameter display format remained stable as the scenario complexity increased, whereas error rates for the traditional parameter display formats with expected-value ranges increased. Subjective results also indicated that the subjects preferred this new format and thought that their performance was better with it. The column deviation parameter display format is recommended for display applications that require rapid recognition of out-of-tolerance conditions, especially for a large number of parameters.

  2. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    PubMed

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  3. Worldwide Regulations of Standard Values of Pesticides for Human Health Risk Control: A Review.

    PubMed

    Li, Zijian; Jennings, Aaron

    2017-07-22

    Abstract : The impact of pesticide residues on human health is a worldwide problem, as human exposure to pesticides can occur through ingestion, inhalation, and dermal contact. Regulatory jurisdictions have promulgated the standard values for pesticides in residential soil, air, drinking water, and agricultural commodity for years. Until now, more than 19,400 pesticide soil regulatory guidance values (RGVs) and 5400 pesticide drinking water maximum concentration levels (MCLs) have been regulated by 54 and 102 nations, respectively. Over 90 nations have provided pesticide agricultural commodity maximum residue limits (MRLs) for at least one of the 12 most commonly consumed agricultural foods. A total of 22 pesticides have been regulated with more than 100 soil RGVs, and 25 pesticides have more than 100 drinking water MCLs. This research indicates that those RGVs and MCLs for an individual pesticide could vary over seven (DDT drinking water MCLs), eight (Lindane soil RGVs), or even nine (Dieldrin soil RGVs) orders of magnitude. Human health risk uncertainty bounds and the implied total exposure mass burden model were applied to analyze the most commonly regulated and used pesticides for human health risk control. For the top 27 commonly regulated pesticides in soil, there are at least 300 RGVs (8% of the total) that are above all of the computed upper bounds for human health risk uncertainty. For the top 29 most-commonly regulated pesticides in drinking water, at least 172 drinking water MCLs (5% of the total) exceed the computed upper bounds for human health risk uncertainty; while for the 14 most widely used pesticides, there are at least 310 computed implied dose limits (28.0% of the total) that are above the acceptable daily intake values. The results show that some worldwide standard values were not derived conservatively enough to avoid human health risk by the pesticides, and that some values were not computed comprehensively by considering all major human

  4. Worldwide Regulations of Standard Values of Pesticides for Human Health Risk Control: A Review

    PubMed Central

    Jennings, Aaron

    2017-01-01

    The impact of pesticide residues on human health is a worldwide problem, as human exposure to pesticides can occur through ingestion, inhalation, and dermal contact. Regulatory jurisdictions have promulgated the standard values for pesticides in residential soil, air, drinking water, and agricultural commodity for years. Until now, more than 19,400 pesticide soil regulatory guidance values (RGVs) and 5400 pesticide drinking water maximum concentration levels (MCLs) have been regulated by 54 and 102 nations, respectively. Over 90 nations have provided pesticide agricultural commodity maximum residue limits (MRLs) for at least one of the 12 most commonly consumed agricultural foods. A total of 22 pesticides have been regulated with more than 100 soil RGVs, and 25 pesticides have more than 100 drinking water MCLs. This research indicates that those RGVs and MCLs for an individual pesticide could vary over seven (DDT drinking water MCLs), eight (Lindane soil RGVs), or even nine (Dieldrin soil RGVs) orders of magnitude. Human health risk uncertainty bounds and the implied total exposure mass burden model were applied to analyze the most commonly regulated and used pesticides for human health risk control. For the top 27 commonly regulated pesticides in soil, there are at least 300 RGVs (8% of the total) that are above all of the computed upper bounds for human health risk uncertainty. For the top 29 most-commonly regulated pesticides in drinking water, at least 172 drinking water MCLs (5% of the total) exceed the computed upper bounds for human health risk uncertainty; while for the 14 most widely used pesticides, there are at least 310 computed implied dose limits (28.0% of the total) that are above the acceptable daily intake values. The results show that some worldwide standard values were not derived conservatively enough to avoid human health risk by the pesticides, and that some values were not computed comprehensively by considering all major human exposure

  5. To Promote, or Not to Promote Fundamental British Values? Teachers' Standards, Diversity and Teacher Education

    ERIC Educational Resources Information Center

    Elton-Chalcraft, Sally; Lander, Vini; Revell, Lynn; Warner, Diane; Whitworth, Linda

    2017-01-01

    In this article we seek to problematize the presence of the requirement within the teachers' standards (DfE, 2012), that they "should not undermine fundamental British values" in the context of initial teacher education in England. The inclusion of this statement within the teachers' code of conduct has made its way from the…

  6. Value Added Models and the Implementation of the National Standards of K-12 Physical Education

    ERIC Educational Resources Information Center

    Seymour, Clancy M.; Garrison, Mark J.

    2017-01-01

    The implementation of value-added models of teacher evaluation continue to expand in public education, but the effects of using student test scores to evaluate K-12 physical educators necessitates further discussion. Using the five National Standards for K-12 Physical Education from the Society of Health and Physical Educators America (SHAPE),…

  7. Quantifying relative importance: Computing standardized effects in models with binary outcomes

    USGS Publications Warehouse

    Grace, James B.; Johnson, Darren; Lefcheck, Jonathan S.; Byrnes, Jarrett E.K.

    2018-01-01

    Results from simulation studies show that both the LT and OE methods of standardization support a similarly-broad range of coefficient comparisons. The LT method estimates effects that reflect underlying latent-linear propensities, while the OE method computes a linear approximation for the effects of predictors on binary responses. The contrast between assumptions for the two methods is reflected in persistently weaker standardized effects associated with OE standardization. Reliance on standard deviations for standardization (the traditional approach) is critically examined and shown to introduce substantial biases when predictors are non-Gaussian. The use of relevant ranges in place of standard deviations has the capacity to place LT and OE standardized coefficients on a more comparable scale. As ecologists address increasingly complex hypotheses, especially those that involve comparing the influences of different controlling factors (e.g., top-down versus bottom-up or biotic versus abiotic controls), comparable coefficients become a necessary component for evaluations.

  8. National Economic Development Procedures Manual - Recreation. Volume 2. A Guide for Using the Contingent Value Methodology in Recreation Studies,

    DTIC Science & Technology

    1986-03-01

    Directly from Sample Bid VI-16 Example 3 VI-16 Determining the Zero Price Qiantity Demanded VI-26 Summary VI -31 CHAPrER VII, THE DETERMINATION OF NED...While the standard deviation and variance are absolute measures of dispersion, a relative measure of dispersion can also be computed. This measure is...refers to the closeness of fit between the estimates obtained from Zli e and the true population value. The only way of being absolutely i: o-.iat the

  9. Inter-rater Agreement on Final Competency Testing Utilizing Standardized Patients.

    PubMed

    Bowman, Dixie H; Ferber, Kyle L; Sima, Adam P

    2016-01-01

    The purpose of this study was to determine whether licensed physical therapists (n=8) serving as standardized patients (SPs) for practical examinations evaluate physical therapy students (n=51) equivalently to the physical therapy course instructor (n=1). The SPs completed the same assessment based on the evaluation criteria as did the instructor. The scores for the practical examination, answers to three questions, and the documentation note were summarized separately for the SP and the instructor by means and standard deviations. A paired t-test and an intraclass correlation coefficient (ICC) for each aspect of the score were calculated. ICC(1,1) values were reported along with corresponding 95% confidence intervals. The instructor had significantly higher scores for the practical exam and the overall score compared to the ratings from the SPs. No differences were observed between the instructor and SP scores on the three answers to the questions and documentation note scores. Based on the ICC values identified in this study, a physical therapist serving as an SP may not be an adequate replacement for an instructor when it comes to grading physical therapy students on all aspects of their competency tests.

  10. 41 CFR 109-1.5304 - Deviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... High Risk Personal Property § 109-1.5304 Deviations. (a) Life cycle control determinations. When the HFO approves a contractor program containing controls, other than life cycle control consistent with... Secretary for Procurement and Assistance Management. A HFO's decision not to provide life-cycle control...

  11. 41 CFR 109-1.5304 - Deviations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... High Risk Personal Property § 109-1.5304 Deviations. (a) Life cycle control determinations. When the HFO approves a contractor program containing controls, other than life cycle control consistent with... Secretary for Procurement and Assistance Management. A HFO's decision not to provide life-cycle control...

  12. 41 CFR 109-1.5304 - Deviations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... High Risk Personal Property § 109-1.5304 Deviations. (a) Life cycle control determinations. When the HFO approves a contractor program containing controls, other than life cycle control consistent with... Secretary for Procurement and Assistance Management. A HFO's decision not to provide life-cycle control...

  13. 41 CFR 109-1.5304 - Deviations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... High Risk Personal Property § 109-1.5304 Deviations. (a) Life cycle control determinations. When the HFO approves a contractor program containing controls, other than life cycle control consistent with... Secretary for Procurement and Assistance Management. A HFO's decision not to provide life-cycle control...

  14. 41 CFR 109-1.5304 - Deviations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... High Risk Personal Property § 109-1.5304 Deviations. (a) Life cycle control determinations. When the HFO approves a contractor program containing controls, other than life cycle control consistent with... Secretary for Procurement and Assistance Management. A HFO's decision not to provide life-cycle control...

  15. Evaluation of Free Breathing Versus Breath Hold Diffusion Weighted Imaging in Terms Apparent Diffusion Coefficient (ADC) and Signal-to-Noise Ratio (SNR) Values for Solid Abdominal Organs.

    PubMed

    Herek, Duygu; Karabulut, Nevzat; Kocyıgıt, Ali; Yagcı, Ahmet Baki

    2016-01-01

    Our aim was to compare the apparent diffusion coefficient (ADC) values of normal abdominal parenchymal organs and signal-to-noise ratio (SNR) measurements in the same patients with breath hold (BH) and free breathing (FB) diffusion weighted imaging (DWI). Forty-eight patients underwent both BH and FB DWI. Spherical region of interest (ROI) was placed on the right hepatic lobe, spleen, pancreas, and renal cortices. ADC values were calculated for each organ on each sequence using an automated software. Image noise, defined as the standard deviation (SD) of the signal intensities in the most artifact-free area of the image background was measured by placing the largest possible ROI on either the left or the right side of the body outside the object in the recorded field of view. SNR was calculated using the formula: SNR=signal intensity (SI) (organ) /standard deviation (SD) (noise) . There were no statistically significant differences in ADC values of the abdominal organs between BH and FB DWI sequences ( p >0.05). There were statistically significant differences between SNR values of organs on BH and FB DWIs. SNRs were found to be better on FB DWI than BH DWI ( p <0.001). Free breathing DWI technique reduces image noise and increases SNR for abdominal examinations. Free breathing technique is therefore preferable to BH DWI in the evaluation of abdominal organs by DWI.

  16. 40 CFR 62.14740 - What must I include in the deviation report?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... your unit deviated from the emission limitations or operating limit requirements. (b) The averaged and recorded data for those dates. (c) Duration and causes of each deviation from the emission limitations or... that deviated from the emission limitations or operating limits specified in this subpart, include the...

  17. Comparison of low-altitude wind-shear statistics derived from measured and proposed standard wind profiles

    NASA Technical Reports Server (NTRS)

    Usry, J. W.

    1983-01-01

    Wind shear statistics were calculated for a simulated set of wind profiles based on a proposed standard wind field data base. Wind shears were grouped in altitude in altitude bands of 100 ft between 100 and 1400 ft and in wind shear increments of 0.025 knot/ft. Frequency distributions, means, and standard deviations for each altitude band were derived for the total sample were derived for both sets. It was found that frequency distributions in each altitude band for the simulated data set were more dispersed below 800 ft and less dispersed above 900 ft than those for the measured data set. Total sample frequency of occurrence for the two data sets was about equal for wind shear values between +0.075 knot/ft, but the simulated data set had significantly larger values for all wind shears outside these boundaries. It is shown that normal distribution in both data sets neither data set was normally distributed; similar results are observed from the cumulative frequency distributions.

  18. Precise determination of the mass of the Higgs boson and tests of compatibility of its couplings with the standard model predictions using proton collisions at 7 and 8

    NASA Astrophysics Data System (ADS)

    Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Bergauer, T.; Dragicevic, M.; Erö, J.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; Kiesenhofer, W.; Knünz, V.; Krammer, M.; Krätschmer, I.; Liko, D.; Mikulec, I.; Rabady, D.; Rahbaran, B.; Rohringer, H.; Schöfbeck, R.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; Bansal, S.; Cornelis, T.; De Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Luyckx, S.; Ochesanu, S.; Rougny, R.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Blekman, F.; Blyweert, S.; D'Hondt, J.; Daci, N.; Heracleous, N.; Keaveney, J.; Lowette, S.; Maes, M.; Olbrechts, A.; Python, Q.; Strom, D.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Onsem, G. P.; Villella, I.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Dobur, D.; Favart, L.; Gay, A. P. R.; Grebenyuk, A.; Léonard, A.; Mohammadi, A.; Perniè, L.; Randle-conde, A.; Reis, T.; Seva, T.; Thomas, L.; Vander Velde, C.; Vanlaer, P.; Wang, J.; Zenoni, F.; Adler, V.; Beernaert, K.; Benucci, L.; Cimmino, A.; Costantini, S.; Crucy, S.; Fagot, A.; Garcia, G.; Mccartin, J.; Ocampo Rios, A. A.; Poyraz, D.; Ryckbosch, D.; Salva Diblen, S.; Sigamani, M.; Strobbe, N.; Thyssen, F.; Tytgat, M.; Yazgan, E.; Zaganidis, N.; Basegmez, S.; Beluffi, C.; Bruno, G.; Castello, R.; Caudron, A.; Ceard, L.; Da Silveira, G. G.; Delaere, C.; du Pree, T.; Favart, D.; Forthomme, L.; Giammanco, A.; Hollar, J.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Nuttens, C.; Pagano, D.; Perrini, L.; Pin, A.; Piotrzkowski, K.; Popov, A.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Vizan Garcia, J. M.; Beliy, N.; Caebergs, T.; Daubie, E.; Hammad, G. H.; Júnior, W. L. Aldá; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Martins, T. Dos Reis; Molina, J.; Mora Herrera, C.; Pol, M. E.; Teles, P. Rebello; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; De Jesus Damiao, D.; De Oliveira Martins, C.; Fonseca De Souza, S.; Malbouisson, H.; Matos Figueiredo, D.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santaolalla, J.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Bernardes, C. A.; Dogra, S.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Aleksandrov, A.; Genchev, V.; Hadjiiska, R.; Iaydjiev, P.; Marinov, A.; Piperov, S.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Cheng, T.; Du, R.; Jiang, C. H.; Plestina, R.; Romeo, F.; Tao, J.; Wang, Z.; Asawatangtrakuldee, C.; Ban, Y.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Zhang, F.; Zhang, L.; Zou, W.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; Gomez Moreno, B.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Polic, D.; Puljak, I.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Kadija, K.; Luetic, J.; Mekterovic, D.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Bodlak, M.; Finger, M.; Finger, M.; Assran, Y.; Ellithi Kame, A.; Mahmoud, M. A.; Radi, A.; Kadastik, M.; Murumaa, M.; Raidal, M.; Tiko, A.; Eerola, P.; Voutilainen, M.; Härkönen, J.; Heikkilä, J. K.; Karimäki, V.; Kinnunen, R.; Kortelainen, M. J.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Mäenpää, T.; Peltola, T.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Locci, E.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Baffioni, S.; Beaudette, F.; Busson, P.; Chapon, E.; Charlot, C.; Dahms, T.; Dobrzynski, L.; Filipovic, N.; Florent, A.; Granier de Cassagnac, R.; Mastrolorenzo, L.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Veelken, C.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Chabert, E. C.; Collard, C.; Conte, E.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Goetzmann, C.; Le Bihan, A.-C.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Beaupere, N.; Bernet, C.; Boudoul, G.; Bouvier, E.; Brochet, S.; Carrillo Montoya, C. A.; Chasserat, J.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Ille, B.; Kurca, T.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Ruiz Alvarez, J. D.; Sabes, D.; Sgandurra, L.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Xiao, H.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Bontenackels, M.; Edelhoff, M.; Feld, L.; Heister, A.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Sammet, J.; Schael, S.; Schulte, J. F.; Weber, H.; Wittmer, B.; Zhukov, V.; Ata, M.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Erdmann, M.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Klingebiel, D.; Knutzen, S.; Kreuzer, P.; Merschmeyer, M.; Meyer, A.; Millet, P.; Olschewski, M.; Padeken, K.; Papacz, P.; Reithler, H.; Schmitz, S. A.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Geenen, H.; Geisler, M.; Haj Ahmad, W.; Hoehle, F.; Kargoll, B.; Kress, T.; Kuessel, Y.; Künsken, A.; Lingemann, J.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Bartosik, N.; Behr, J.; Behrens, U.; Bell, A. J.; Bethani, A.; Borras, K.; Burgmeier, A.; Cakir, A.; Calligaris, L.; Campbell, A.; Choudhury, S.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Dooling, S.; Dorland, T.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Flucke, G.; Garcia, J. Garay; Geiser, A.; Gizhko, A.; Gunnellini, P.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Katsas, P.; Kieseler, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Lutz, B.; Mankel, R.; Marfin, I.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Naumann-Emme, S.; Nayak, A.; Ntomari, E.; Perrey, H.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Ribeiro Cipriano, P. M.; Roland, B.; Ron, E.; Sahin, M. Ö.; Salfeld-Nebgen, J.; Saxena, P.; Schoerner-Sadenius, T.; Schröder, M.; Seitz, C.; Spannagel, S.; Vargas Trevino, A. D. R.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Erfle, J.; Garutti, E.; Goebel, K.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Kirschenmann, H.; Klanner, R.; Kogler, R.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Ott, J.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Poehlsen, T.; Rathjens, D.; Sander, C.; Schettler, H.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Seidel, M.; Sola, V.; Stadie, H.; Steinbrück, G.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Barth, C.; Baus, C.; Berger, J.; Böser, C.; Butz, E.; Chwalek, T.; De Boer, W.; Descroix, A.; Dierlamm, A.; Feindt, M.; Frensch, F.; Giffels, M.; Gilbert, A.; Hartmann, F.; Hauth, T.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Mozer, M. U.; Müller, T.; Müller, Th.; Nürnberg, A.; Quast, G.; Rabbertz, K.; Röcker, S.; Simonis, H. J.; Stober, F. M.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weiler, T.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Markou, A.; Markou, C.; Psallidas, A.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Stiliaris, E.; Tziaferi, E.; Aslanoglou, X.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Bencze, G.; Hajdu, C.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Palinkas, J.; Szillasi, Z.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Swain, S. K.; Beri, S. B.; Bhatnagar, V.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, M.; Kumar, R.; Mittal, M.; Nishu, N.; Singh, J. B.; Kumar, Ashok; Kumar, Arun; Ahuja, S.; Bhardwaj, A.; Choudhary, B. C.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, V.; Banerjee, S.; Bhattacharya, S.; Chatterjee, K.; Dutta, S.; Gomber, B.; Jain, Sa.; Jain, Sh.; Khurana, R.; Modak, A.; Mukherjee, S.; Roy, D.; Sarkar, S.; Sharan, M.; Abdulsalam, A.; Dutta, D.; Kumar, V.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, S.; Bhowmik, S.; Chatterjee, R. M.; Dewanjee, R. K.; Dugad, S.; Ganguly, S.; Ghosh, S.; Guchait, M.; Gurtu, A.; Kole, G.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Mohanty, G. B.; Parida, B.; Sudhakar, K.; Wickramage, N.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Etesami, S. M.; Fahim, A.; Goldouzian, R.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Chhibra, S. S.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Benvenuti, A. C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Travaglini, R.; Albergo, S.; Cappello, G.; Chiorboli, M.; Costa, S.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gallo, E.; Gonzi, S.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Tropiano, A.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Ferretti, R.; Ferro, F.; Lo Vetere, M.; Robutti, E.; Tosi, S.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Gerosa, R.; Ghezzi, A.; Govoni, P.; Lucchini, M. T.; Malvezzi, S.; Manzoni, R. A.; Martelli, A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Iorio, A. O. M.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Azzi, P.; Bacchetta, N.; Biselloa, D.; Branca, A.; Carlin, R.; Checchia, P.; Dall'Osso, M.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Gozzelino, A.; Kanishchev, K.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Pazzini, J.; Pozzobon, N.; Ronchese, P.; Simonetto, F.; Torassa, E.; Tosi, M.; Zotto, P.; Zucchetta, A.; Zumerle, G.; Gabusi, M.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vitulo, P.; Biasini, M.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Spiezia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Broccolo, G.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Fiori, F.; Foà, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Moon, C. S.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Serban, A. T.; Spagnolo, P.; Squillacioti, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Vernieri, C.; Barone, L.; Cavallari, F.; D'imperio, G.; Del Re, D.; Diemoz, M.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Micheli, F.; Organtini, G.; Paramatti, R.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Soffi, L.; Traczyk, P.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Biino, C.; Cartiglia, N.; Casasso, S.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Musich, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Potenza, A.; Romero, A.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Tamponi, U.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; La Licata, C.; Marone, M.; Schizzi, A.; Umer, T.; Zanetti, A.; Chang, S.; Kropivnitskaya, T. A.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Kim, M. S.; Kong, D. J.; Lee, S.; Oh, Y. D.; Park, H.; Sakharov, A.; Son, D. C.; Kim, T. J.; Ryu, M. S.; Kim, J. Y.; Moon, D. H.; Song, S.; Choi, S.; Gyun, D.; Hong, B.; Jo, M.; Kim, H.; Kim, Y.; Lee, B.; Lee, K. S.; Park, S. K.; Roh, Y.; Yoo, H. D.; Choi, M.; Kim, J. H.; Park, I. C.; Ryu, G.; Choi, Y.; Choi, Y. K.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Juodagalvis, A.; Komaragiri, J. R.; Md Ali, M. A. B.; Wan Abdullah, W. A. T.; Casimiro Linares, E.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-de La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Reucroft, S.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Khurshid, T.; Shoaib, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Brona, G.; Bunkowski, K.; Cwiok, M.; Dominik, W.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Faccioli, P.; Parracho, P. G. Ferreira; Gallinaro, M.; Lloret Iglesias, L.; Nguyen, F.; Rodrigues Antunes, J.; Seixas, J.; Varela, J.; Vischia, P.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Konoplyanikov, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Skatchkov, N.; Smirnov, V.; Zarubin, A.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Vorobyev, An.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Semenov, S.; Spiridonov, A.; Stolin, V.; Vlasov, E.; Zhokin, A.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Mesyats, G.; Rusakov, S. V.; Vinogradov, A.; Belyaev, A.; Boos, E.; Bunichev, V.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Ekmedzic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Battilana, C.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Domínguez Vázquez, D.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Ramos, J. P. Fernández; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Yzquierdo, A. Pérez-Calero; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Albajar, C.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Brun, H.; Cuevas, J.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; Brochero Cifuentes, J. A.; Cabrillo, I. J.; Calderon, A.; Duarte Campderros, J.; Fernandez, M.; Gomez, G.; Graziano, A.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Matorras, F.; Munoz Sanchez, F. J.; Piedra Gomez, J.; Rodrigo, T.; Rodríguez-Marrero, A. Y.; Ruiz-Jimeno, A.; Scodellaro, L.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Benaglia, A.; Bendavid, J.; Benhabib, L.; Benitez, J. F.; Bloch, P.; Bocci, A.; Bonato, A.; Bondu, O.; Botta, C.; Breuker, H.; Camporesi, T.; Cerminara, G.; Colafranceschi, S.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; David, A.; De Guio, F.; De Roeck, A.; De Visscher, S.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; Dupont-Sagorin, N.; Elliott-Peisert, A.; Franzoni, G.; Funk, W.; Gigi, D.; Gill, K.; Giordano, D.; Girone, M.; Glege, F.; Guida, R.; Gundacker, S.; Guthoff, M.; Hammer, J.; Hansen, M.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kousouris, K.; Krajczar, K.; Lecoq, P.; Lourenço, C.; Magini, N.; Malgeri, L.; Mannelli, M.; Marrouche, J.; Masetti, L.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pimiä, M.; Piparo, D.; Plagge, M.; Racz, A.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Sharma, A.; Siegrist, P.; Silva, P.; Simon, M.; Sphicas, P.; Spiga, D.; Steggemann, J.; Stieger, B.; Stoye, M.; Takahashi, Y.; Treille, D.; Tsirou, A.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Wollny, H.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Renker, D.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Buchmann, M. A.; Casal, B.; Chanon, N.; Dissertori, G.; Dittmar, M.; Donegà, M.; Dünser, M.; Eller, P.; Grab, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marini, A. C.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meister, D.; Mohr, N.; Musella, P.; Nägeli, C.; Nessi-Tedaldi, F.; Pandolfi, F.; Pauss, F.; Perrozzi, L.; Peruzzi, M.; Quittnat, M.; Rebane, L.; Rossini, M.; Starodumov, A.; Takahashi, M.; Theofilatos, K.; Wallny, R.; Weber, H. A.; Amsler, C.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Ronga, F. J.; Taroni, S.; Yang, Y.; Cardaci, M.; Chen, K. H.; Ferro, C.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Volpe, R.; Yu, S. S.; Chang, P.; Chang, Y. H.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Grundler, U.; Hou, W.-S.; Liu, Y. F.; Lu, R.-S.; Mi nano Moya, M.; Petrakou, E.; Tsai, J. F.; Tzeng, Y. M.; Wilken, R.; Asavapibhop, B.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Bakirci, M. N.; Cerci, S.; Dozen, C.; Dumanoglu, I.; Eskut, E.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Kayis Topaksu, A.; Onengut, G.; Ozdemir, K.; Ozturk, S.; Polatoz, A.; Sunar Cerci, D.; Tali, B.; Topakli, H.; Vergili, M.; Zorbilmez, C.; Akin, I. V.; Bilin, B.; Bilmis, S.; Gamsizkan, H.; Isildak, B.; Karapinar, G.; Ocalan, K.; Sekmen, S.; Surat, U. E.; Yalvac, M.; Zeyrek, M.; Albayrak, E. A.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, T.; Cankocak, K.; Vardarlı, F. I.; Levchuk, L.; Sorokin, P.; Brooke, J. J.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Senkin, S.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Womersley, W. J.; Worm, S. D.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Burton, D.; Colling, D.; Cripps, N.; Dauncey, P.; Davies, G.; Della Negra, M.; Dunne, P.; Elwood, A.; Ferguson, W.; Fulcher, J.; Futyan, D.; Hall, G.; Iles, G.; Jarvis, M.; Karapostoli, G.; Kenzie, M.; Lane, R.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mathias, B.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Petridis, K.; Raymond, D. M.; Rogerson, S.; Rose, A.; Seez, C.; Sharp, P.; Tapper, A.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leggat, D.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Dittmann, J.; Hatakeyama, K.; Kasmi, A.; Liu, H.; Pastika, N.; Scarborough, T.; Wu, Z.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Avetisyan, A.; Bose, T.; Fantasia, C.; Lawson, P.; Richardson, C.; Rohlf, J.; St. John, J.; Sulak, L.; Alimena, J.; Berry, E.; Bhattacharya, S.; Christopher, G.; Cutts, D.; Demiragli, Z.; Dhingra, N.; Ferapontov, A.; Garabedian, A.; Heintz, U.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Sagir, S.; Sinthuprasith, T.; Speer, T.; Swanson, J.; Breedon, R.; Breto, G.; De La Barca Sanchez, M. Calderon; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Gardner, M.; Ko, W.; Lander, R.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Farrell, C.; Hauser, J.; Ignatenko, M.; Rakness, G.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Ivova Rikova, M.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Luthra, A.; Malberti, M.; Negrete, M. Olmedo; Shrinivas, A.; Sumowidagdo, S.; Wimpenny, S.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Palmer, C.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Tu, Y.; Vartak, A.; Welke, C.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Barge, D.; Bradmiller-Feld, J.; Campagnari, C.; Danielson, T.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Incandela, J.; Justus, C.; Mccoll, N.; Mullin, S. D.; Richman, J.; Stuart, D.; To, W.; West, C.; Yoo, J.; Apresyan, A.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Pierini, M.; Spiropulu, M.; Vlimant, R.; Wilkinson, R.; Xie, S.; Zhu, R. Y.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Iiyama, Y.; Paulini, M.; Russ, J.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Gaz, A.; Krohn, M.; Luiggi Lopez, E.; Nauenberg, U.; Smith, J. G.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chatterjee, A.; Chaves, J.; Chu, J.; Dittmer, S.; Eggert, N.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Ryd, A.; Salvati, E.; Skinnari, L.; Sun, W.; Teo, W. D.; Thom, J.; Thompson, J.; Tucker, J.; Weng, Y.; Winstrom, L.; Wittich, P.; Winn, D.; Abdullin, S.; Albrow, M.; Anderson, J.; Apollinari, G.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Hare, D.; Harris, R. M.; Hirschauer, J.; Hooberman, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Kwan, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Martinez Outschoorn, V. I.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mishra, K.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Prokofyev, O.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vidal, R.; Whitbeck, A.; Whitmore, J.; Yang, F.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Carver, M.; Curry, D.; Das, S.; De Gruttola, M.; Di Giovanni, G. P.; Field, R. D.; Fisher, M.; Furic, I. K.; Hugon, J.; Konigsberg, J.; Korytov, A.; Kypreos, T.; Low, J. F.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Muniz, L.; Rinkevicius, A.; Shchutska, L.; Snowball, M.; Sperka, D.; Yelton, J.; Zakaria, M.; Hewamanage, S.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Adams, J. R.; Adams, T.; Askew, A.; Bochenek, J.; Diamond, B.; Haas, J.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Prosper, H.; Veeraraghavan, V.; Weinberg, M.; Baarmand, M. M.; Hohlmann, M.; Kalakhety, H.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Silkworth, C.; Turner, P.; Varelas, N.; Bilki, B.; Clarida, W.; Dilsiz, K.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Rahmat, R.; Sen, S.; Tan, P.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Barnett, B. A.; Blumenfeld, B.; Bolognesi, S.; Fehling, D.; Gritsan, A. V.; Maksimovic, P.; Martin, C.; Swartz, M.; Xiao, M.; Baringer, P.; Bean, A.; Benelli, G.; Bruner, C.; Gray, J.; Kenny, R. P.; Majumder, D.; Malek, M.; Murray, M.; Noonan, D.; Sanders, S.; Sekaric, J.; Stringer, R.; Wang, Q.; Wood, J. S.; Chakaberia, I.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Saini, L. K.; Skhirtladze, N.; Svintradze, I.; Gronberg, J.; Lange, D.; Rebassoo, F.; Wright, D.; Baden, A.; Belloni, A.; Calvert, B.; Eno, S. C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Lu, Y.; Mignerey, A. C.; Pedro, K.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Bierwagen, K.; Busza, W.; Cali, I. A.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Klute, M.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Paus, C.; Ralph, D.; Roland, C.; Roland, G.; Stephans, G. S. F.; Sumorok, K.; Velicanu, D.; Veverka, J.; Wyslouch, B.; Yang, M.; Zanetti, M.; Zhukova, V.; Dahmes, B.; Gude, A.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Mans, J.; Nourbakhsh, S.; Rusack, R.; Singovsky, A.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Gonzalez Suarez, R.; Keller, J.; Knowlton, D.; Kravchenko, I.; Lazo-Flores, J.; Meier, F.; Ratnikov, F.; Snow, G. R.; Zvada, M.; Dolen, J.; Godshalk, A.; Iashvili, I.; Kharchilava, A.; Kumar, A.; Rappoccio, S.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Trocino, D.; Wang, R. J.; Wood, D.; Zhang, J.; Hahn, K. A.; Kubik, A.; Mucia, N.; Odell, N.; Pollack, B.; Pozdnyakov, A.; Schmitt, M.; Stoynev, S.; Sung, K.; Velasco, M.; Won, S.; Brinkerhoff, A.; Chan, K. M.; Drozdetskiy, A.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Lynch, S.; Marinelli, N.; Musienko, Y.; Pearson, T.; Planer, M.; Ruchti, R.; Smith, G.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Hart, A.; Hill, C.; Hughes, R.; Kotov, K.; Ling, T. Y.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wolfe, H.; Wulsin, H. W.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Koay, S. A.; Lujan, P.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Piroué, P.; Quan, X.; Saka, H.; Stickland, D.; Tully, C.; Werner, J. S.; Zuranski, A.; Brownson, E.; Malik, S.; Mendez, H.; Ramirez Vargas, J. E.; Barnes, V. E.; Benedetti, D.; Bortoletto, D.; Gutay, L.; Hu, Z.; Jha, M. K.; Jones, M.; Jung, K.; Kress, M.; Leonardo, N.; Miller, D. H.; Neumeister, N.; Primavera, F.; Radburn-Smith, B. C.; Shi, X.; Shipsey, I.; Silvers, D.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Zablocki, J.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Ecklund, K. M.; Geurts, F. J. M.; Li, W.; Michlin, B.; Padley, B. P.; Redjimi, R.; Roberts, J.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Eshaq, Y.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Goldenzweig, P.; Han, J.; Harel, A.; Hindrichs, O.; Khukhunaishvili, A.; Korjenevski, S.; Petrillo, G.; Verzetti, M.; Vishnevskiy, D.; Ciesielski, R.; Demortier, L.; Goulianos, K.; Mesropian, C.; Arora, S.; Barker, A.; Chou, J. P.; Contreras-Campana, C.; Contreras-Campana, E.; Duggan, D.; Ferencek, D.; Gershtein, Y.; Gray, R.; Halkiadakis, E.; Hidas, D.; Kaplan, S.; Lath, A.; Panwalkar, S.; Park, M.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Rose, K.; Spanier, S.; York, A.; Bouhali, O.; Castaneda Hernandez, A.; Dalchenko, M.; De Mattia, M.; Dildick, S.; Eusebi, R.; Flanagan, W.; Gilmore, J.; Kamon, T.; Khotilovich, V.; Krutelyov, V.; Montalvo, R.; Osipenkov, I.; Pakhotin, Y.; Patel, R.; Perloff, A.; Roe, J.; Rose, A.; Safonov, A.; Suarez, I.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kovitanggoon, K.; Kunori, S.; Lee, S. W.; Libeiro, T.; Volobouev, I.; Appelt, E.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Johns, W.; Maguire, C.; Mao, Y.; Melo, A.; Sharma, M.; Sheldon, P.; Snook, B.; Tuo, S.; Velkovska, J.; Arenton, M. W.; Boutle, S.; Cox, B.; Francis, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Lin, C.; Neu, C.; Wolfe, E.; Wood, J.; Clarke, C.; Harr, R.; Karchin, P. E.; Kottachchi Kankanamge Don, C.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Carlsmith, D.; Cepeda, M.; Dasu, S.; Dodd, L.; Duric, S.; Friis, E.; Hall-Wilton, R.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Lazaridis, C.; Levine, A.; Loveless, R.; Mohapatra, A.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ross, I.; Sarangi, T.; Savin, A.; Smith, W. H.; Taylor, D.; Vuosalo, C.; Woods, N.; Roinishvili, V.

    2015-05-01

    Properties of the Higgs boson with mass near 125 are measured in proton-proton collisions with the CMS experiment at the LHC. Comprehensive sets of production and decay measurements are combined. The decay channels include , , , , , and pairs. The data samples were collected in 2011 and 2012 and correspond to integrated luminosities of up to 5.1 at 7 and up to 19.7 at 8. From the high-resolution and channels, the mass of the Higgs boson is determined to be . For this mass value, the event yields obtained in the different analyses tagging specific decay channels and production mechanisms are consistent with those expected for the standard model Higgs boson. The combined best-fit signal relative to the standard model expectation is at the measured mass. The couplings of the Higgs boson are probed for deviations in magnitude from the standard model predictions in multiple ways, including searches for invisible and undetected decays. No significant deviations are found.

  19. Quantifying prosthetic gait deviation using simple outcome measures

    PubMed Central

    Kark, Lauren; Odell, Ross; McIntosh, Andrew S; Simmons, Anne

    2016-01-01

    AIM: To develop a subset of simple outcome measures to quantify prosthetic gait deviation without needing three-dimensional gait analysis (3DGA). METHODS: Eight unilateral, transfemoral amputees and 12 unilateral, transtibial amputees were recruited. Twenty-eight able-bodied controls were recruited. All participants underwent 3DGA, the timed-up-and-go test and the six-minute walk test (6MWT). The lower-limb amputees also completed the Prosthesis Evaluation Questionnaire. Results from 3DGA were summarised using the gait deviation index (GDI), which was subsequently regressed, using stepwise regression, against the other measures. RESULTS: Step-length (SL), self-selected walking speed (SSWS) and the distance walked during the 6MWT (6MWD) were significantly correlated with GDI. The 6MWD was the strongest, single predictor of the GDI, followed by SL and SSWS. The predictive ability of the regression equations were improved following inclusion of self-report data related to mobility and prosthetic utility. CONCLUSION: This study offers a practicable alternative to quantifying kinematic deviation without the need to conduct complete 3DGA. PMID:27335814

  20. 48 CFR 201.404 - Class deviations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and the Defense Logistics Agency, may approve any class deviation, other than those described in 201...) Diminish any preference given small business concerns by the FAR or DFARS; or (D) Extend to requirements imposed by statute or by regulations of other agencies such as the Small Business Administration and the...

  1. Large deviations in the presence of cooperativity and slow dynamics

    NASA Astrophysics Data System (ADS)

    Whitelam, Stephen

    2018-06-01

    We study simple models of intermittency, involving switching between two states, within the dynamical large-deviation formalism. Singularities appear in the formalism when switching is cooperative or when its basic time scale diverges. In the first case the unbiased trajectory distribution undergoes a symmetry breaking, leading to a change in shape of the large-deviation rate function for a particular dynamical observable. In the second case the symmetry of the unbiased trajectory distribution remains unbroken. Comparison of these models suggests that singularities of the dynamical large-deviation formalism can signal the dynamical equivalent of an equilibrium phase transition but do not necessarily do so.

  2. 48 CFR 1352.219-71 - Notification to delay performance (Deviation).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... not begin performance under this purchase order until 2 working days have passed from the date of its... performance (Deviation). 1352.219-71 Section 1352.219-71 Federal Acquisition Regulations System DEPARTMENT OF....219-71 Notification to delay performance (Deviation). As prescribed in 48 CFR 1319.811-3(b), insert...

  3. 10 CFR 1017.5 - Requesting a deviation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... create a potential or real vulnerability); or (3) An exception (i.e., an approved deviation from a requirement in these regulations for which DOE accepts the risk of a safeguards and security vulnerability...

  4. Large-deviation theory for diluted Wishart random matrices

    NASA Astrophysics Data System (ADS)

    Castillo, Isaac Pérez; Metz, Fernando L.

    2018-03-01

    Wishart random matrices with a sparse or diluted structure are ubiquitous in the processing of large datasets, with applications in physics, biology, and economy. In this work, we develop a theory for the eigenvalue fluctuations of diluted Wishart random matrices based on the replica approach of disordered systems. We derive an analytical expression for the cumulant generating function of the number of eigenvalues IN(x ) smaller than x ∈R+ , from which all cumulants of IN(x ) and the rate function Ψx(k ) controlling its large-deviation probability Prob[IN(x ) =k N ] ≍e-N Ψx(k ) follow. Explicit results for the mean value and the variance of IN(x ) , its rate function, and its third cumulant are discussed and thoroughly compared to numerical diagonalization, showing very good agreement. The present work establishes the theoretical framework put forward in a recent letter [Phys. Rev. Lett. 117, 104101 (2016), 10.1103/PhysRevLett.117.104101] as an exact and compelling approach to deal with eigenvalue fluctuations of sparse random matrices.

  5. Do volunteer community-based preceptors value students' feedback?

    PubMed

    Dent, M Marie; Boltri, John; Okosun, Ike S

    2004-11-01

    A key component of educational practice is to provide feedback and evaluation to teachers and learners to improve the teaching and learning process. The purpose of this study was to determine whether volunteer community preceptors value evaluation and feedback by students as much as they value other resources or rewards. In Fall 1999, a questionnaire concerning the resources and rewards of preceptorship was mailed to 236 community preceptors affiliated with the Mercer University School of Medicine, Macon, Georgia. Preceptors were asked to rate 20 factors on a five-point Likert scale (5 = very important to 1 = not very important). The mean values were compared using t-tests. One hundred sixty-eight preceptors (71%) completed questionnaires. Preceptors rated evaluation and feedback from students significantly higher (p < .001) than all other factors (mean = 4.02, standard deviation [SD] = .87). Continuing medical education for teaching was the next most highly valued factor (mean = 3.67, SD = 1.14). Preceptors rated financial compensation the lowest (mean = 2.01, SD = 1.19) of all factors. The high rank of feedback and evaluation from students persisted across gender, specialty, length of time as a preceptor, practice location, and years practicing medicine. This study demonstrates that feedback and evaluation from students is highly valued. The knowledge that community-based preceptors highly value feedback and evaluation from students should stimulate medical school programs to provide feedback and evaluation to preceptors that will enhance the educational outcomes for both faculty and learners.

  6. The phonatory deviation diagram: a novel objective measurement of vocal function.

    PubMed

    Madazio, Glaucya; Leão, Sylvia; Behlau, Mara

    2011-01-01

    To identify the discriminative characteristics of the phonatory deviation diagram (PDD) in rough, breathy and tense voices. One hundred and ninety-six samples of normal and dysphonic voices from adults were submitted to perceptual auditory evaluation, focusing on the predominant vocal quality and the degree of deviation. Acoustic analysis was performed with the VoxMetria (CTS Informatica). Significant differences were observed between the dysphonic and normal groups (p < 0.001), and also between the breathy and rough samples (p = 0.044) and the breathy and tense samples (p < 0.001). All normal voices were positioned in the inferior left quadrant, 45% of the rough voices in the inferior right quadrant, 52.6% of the breathy voices in the superior right quadrant and 54.3% of the tense voices in the inferior left quadrant of the PDD. In the inferior left quadrant, 93.8% of voices with no deviation were located and 72.7% of voices with mild deviation; voices with moderate deviation were distributed in the inferior and superior right quadrants, the latter ones containing the most deviant voices and 80% of voices with severe deviation. The PDD was able to discriminate normal from dysphonic voices, and the distribution was related to the type and degree of voice alteration. Copyright © 2011 S. Karger AG, Basel.

  7. Methodological Issues in Meta-Analyzing Standard Deviations: Comment on Bond and DePaulo (2008)

    ERIC Educational Resources Information Center

    Pigott, Therese D.; Wu, Meng-Jia

    2008-01-01

    In this comment on C. F. Bond and B. M. DePaulo, the authors raise methodological concerns about the approach used to analyze the data. The authors suggest further refinement of the procedures used, and they compare the approach taken by Bond and DePaulo with standard methods for meta-analysis. (Contains 1 table and 2 figures.)

  8. Large Deviations: Advanced Probability for Undergrads

    ERIC Educational Resources Information Center

    Rolls, David A.

    2007-01-01

    In the branch of probability called "large deviations," rates of convergence (e.g. of the sample mean) are considered. The theory makes use of the moment generating function. So, particularly for sums of independent and identically distributed random variables, the theory can be made accessible to senior undergraduates after a first course in…

  9. Minimization of deviations of gear real tooth surfaces determined by coordinate measurements

    NASA Technical Reports Server (NTRS)

    Litvin, F. L.; Kuan, C.; Wang, J.-C.; Handschuh, R. F.; Masseth, J.; Maruyama, N.

    1992-01-01

    The deviations of a gear's real tooth surface from the theoretical surface are determined by coordinate measurements at the grid of the surface. A method was developed to transform the deviations from Cartesian coordinates to those along the normal at the measurement locations. Equations are derived that relate the first order deviations with the adjustment to the manufacturing machine-tool settings. The deviations of the entire surface are minimized. The minimization is achieved by application of the least-square method for an overdetermined system of linear equations. The proposed method is illustrated with a numerical example for hypoid gear and pinion.

  10. Packing Fraction of a Two-dimensional Eden Model with Random-Sized Particles

    NASA Astrophysics Data System (ADS)

    Kobayashi, Naoki; Yamazaki, Hiroshi

    2018-01-01

    We have performed a numerical simulation of a two-dimensional Eden model with random-size particles. In the present model, the particle radii are generated from a Gaussian distribution with mean μ and standard deviation σ. First, we have examined the bulk packing fraction for the Eden cluster and investigated the effects of the standard deviation and the total number of particles NT. We show that the bulk packing fraction depends on the number of particles and the standard deviation. In particular, for the dependence on the standard deviation, we have determined the asymptotic value of the bulk packing fraction in the limit of the dimensionless standard deviation. This value is larger than the packing fraction obtained in a previous study of the Eden model with uniform-size particles. Secondly, we have investigated the packing fraction of the entire Eden cluster including the effect of the interface fluctuation. We find that the entire packing fraction depends on the number of particles while it is independent of the standard deviation, in contrast to the bulk packing fraction. In a similar way to the bulk packing fraction, we have obtained the asymptotic value of the entire packing fraction in the limit NT → ∞. The obtained value of the entire packing fraction is smaller than that of the bulk value. This fact suggests that the interface fluctuation of the Eden cluster influences the packing fraction.

  11. Large deviation function for a driven underdamped particle in a periodic potential

    NASA Astrophysics Data System (ADS)

    Fischer, Lukas P.; Pietzonka, Patrick; Seifert, Udo

    2018-02-01

    Employing large deviation theory, we explore current fluctuations of underdamped Brownian motion for the paradigmatic example of a single particle in a one-dimensional periodic potential. Two different approaches to the large deviation function of the particle current are presented. First, we derive an explicit expression for the large deviation functional of the empirical phase space density, which replaces the level 2.5 functional used for overdamped dynamics. Using this approach, we obtain several bounds on the large deviation function of the particle current. We compare these to bounds for overdamped dynamics that have recently been derived, motivated by the thermodynamic uncertainty relation. Second, we provide a method to calculate the large deviation function via the cumulant generating function. We use this method to assess the tightness of the bounds in a numerical case study for a cosine potential.

  12. Syntactic Deviations in the Novel "The Sound and the Fury"

    ERIC Educational Resources Information Center

    Alirezazadeh, Pooria; Talebinezhad, Mohammad Reza

    2014-01-01

    This article looks at William Faulkner's work "The Sound and the Fury." The goals are to investigate different types of syntactic deviations in the novel, and how these deviations helped the writer to create a literary work in the field of modernist literature and stream of consciousness. To this end, the theoretical framework for…

  13. Deviation from niche optima affects the nature of plant–plant interactions along a soil acidity gradient

    PubMed Central

    He, Lei; Cheng, Lulu; Hu, Liangliang; Tang, Jianjun; Chen, Xin

    2016-01-01

    There is increasing recognition of the importance of niche optima in the shift of plant–plant interactions along environmental stress gradients. Here, we investigate whether deviation from niche optima would affect the outcome of plant–plant interactions along a soil acidity gradient (pH = 3.1, 4.1, 5.5 and 6.1) in a pot experiment. We used the acid-tolerant species Lespedeza formosa Koehne as the neighbouring plant and the acid-tolerant species Indigofera pseudotinctoria Mats. or acid-sensitive species Medicago sativa L. as the target plants. Biomass was used to determine the optimal pH and to calculate the relative interaction index (RII). We found that the relationships between RII and the deviation of soil pH from the target's optimal pH were linear for both target species. Both targets were increasingly promoted by the neighbour as pH values deviated from their optima; neighbours benefitted target plants by promoting soil symbiotic arbuscular mycorrhizal fungi, increasing soil organic matter or reducing soil exchangeable aluminium. Our results suggest that the shape of the curve describing the relationship between soil pH and facilitation/competition depends on the soil pH optima of the particular species. PMID:26740568

  14. Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment.

    PubMed

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; Motroni, Alessandro; van der Stelt, Paul; Wismeijer, Daniel

    2012-01-01

    To assess the reliability of cone beam computed tomography (CBCT) voxel gray value measurements using Hounsfield units (HU) derived from multislice computed tomography (MSCT) as a clinical reference (gold standard). Ten partially edentulous human mandibular cadavers were scanned by two types of computed tomography (CT) modalities: multislice CT and cone beam CT. On MSCT scans, eight regions of interest (ROI) designating the site for preoperative implant placement were selected in each mandible. The datasets from both CT systems were matched using a three-dimensional (3D) registration algorithm. The mean voxel gray values of the region around the implant sites were compared between MSCT and CBCT. Significant differences between the mean gray values obtained by CBCT and HU by MSCT were found. In all the selected ROIs, CBCT showed higher mean values than MSCT. A strong correlation (R=0.968) between mean voxel gray values of CBCT and mean HU of MSCT was determined. Voxel gray values from CBCT deviate from actual HU units. However, a strong linear correlation exists, which may permit deriving actual HU units from CBCT using linear regression models.

  15. Gait Deviations in Children With Osteogenesis Imperfecta Type I.

    PubMed

    Garman, Christina R; Graf, Adam; Krzak, Joseph; Caudill, Angela; Smith, Peter; Harris, Gerald

    2017-08-02

    Osteogenesis imperfecta (OI) is a congenital connective tissue disorder often characterized by orthopaedic complications that impact normal gait. As such, mobility is of particular interest in the OI population as it is associated with multiple aspects of participation and quality of life. The purpose of the current study was to identify and describe common gait deviations in a large sample of individuals with type I OI and speculate the etiology with a goal of improving function. Gait analysis was performed on 44 subjects with type I (11.7±3.08 y old) and 30 typically developing controls (9.54±3.1 y old ). Spatial temporal, kinematic, and kinetic gait data were calculated from the Vicon Plug-in-Gait Model. Musculoskeletal modeling of the muscle tendon lengths (MTL) was done in OpenSim 3.3 to evaluate the MTL of the gastrocnemius and gluteus maximus. The gait deviation index, a dimensionless parameter that evaluates the deviation of 9 kinematic gait parameters from a control database, was also calculated. Walking speed, single support time, stride, and step length were lower and double support time was higher in the OI group. The gait deviation index score was lower and external hip rotation angle was higher in the OI group. Peak hip flexor, knee extensor and ankle plantarflexor moments, and power generation at the ankle were lower in the OI group. MTL analysis revealed no significant length discrepancies between the OI group and the typically developing group. Together, these findings provide a comprehensive description of gait characteristics among a group of individuals with type I OI. Such data inform clinicians about specific gait deviations in this population allowing clinicians to recommend more focused interventions. Level III-case-control study.

  16. The Effect of Patient Age on Standardized, Uptake Value-Hounsfield Unit Values of Male Genitourinery Structures In F-18 FDG PET/CT

    PubMed Central

    Çavuşoğlu, Berrin; Durak, Hatice

    2011-01-01

    Objective: Relation between patient age and Hounsfield Unit (HU),which is the linear attenuation coefficient, and Standardized Uptake Values (SUV) which is the amount of 18F-fluorodeoxyglucose (F-18 FDG) uptake, measured in the areas of interest drawn to prostate, seminal vesicles and testicles in F-18 FDG Positron Emission Tomography/Computed Tomography (PET/CT) images was investigated. Material and Methods: Mean and maximum SUV and HU values were recorded from the areas of interest (min 12 mm in diameter) which showed FDG uptake in prostate, seminal vesicles and testicles from F-18 FDG PET-CT images of 21 male patients under 40 years without genitourinary cancer. The effect of patient age to SUV and HU values was examined with Pearson correlation test using SPSS program. Results: There was a negative insignificant correlation between patient age and SUV and HU values for prostate. For seminal vesicles, correlation between patient age and SUV values and HUmax were positive but insignificant, while correlation with HUmean was significant (r=0.459, p=0.00). Correlation between patient age and SUVmax and SUVmean values were significant for testicles (r=0.506, p=0.002 and r=0.467, p=0.005, respectively) but the correlation between patient age and HUmax and HUmean values was not significant. Conclusion: F-18 FDG uptake in testicles in males increases with age until 40, suggesting an increase in metabolic rate. The significant correlation between age and mean HU values is probably caused by thickening of the tissue without an increase in glucose metabolism in seminal vesicles. In prostate, the effect of patient age to SUV and HU values was not observed until the age 40. Conflict of interest:None declared. PMID:23486855

  17. Gait deviations in Duchenne muscular dystrophy-Part 2. Statistical non-parametric mapping to analyze gait deviations in children with Duchenne muscular dystrophy.

    PubMed

    Goudriaan, Marije; Van den Hauwe, Marleen; Simon-Martinez, Cristina; Huenaerts, Catherine; Molenaers, Guy; Goemans, Nathalie; Desloovere, Kaat

    2018-04-30

    Prolonged ambulation is considered important in children with Duchenne muscular dystrophy (DMD). However, previous studies analyzing DMD gait were sensitive to false positive outcomes, caused by uncorrected multiple comparisons, regional focus bias, and inter-component covariance bias. Also, while muscle weakness is often suggested to be the main cause for the altered gait pattern in DMD, this was never verified. Our research question was twofold: 1) are we able to confirm the sagittal kinematic and kinetic gait alterations described in a previous review with statistical non-parametric mapping (SnPM)? And 2) are these gait deviations related to lower limb weakness? We compared gait kinematics and kinetics of 15 children with DMD and 15 typical developing (TD) children (5-17 years), with a two sample Hotelling's T 2 test and post-hoc two-tailed, two-sample t-test. We used canonical correlation analyses to study the relationship between weakness and altered gait parameters. For all analyses, α-level was corrected for multiple comparisons, resulting in α = 0.005. We only found one of the previously reported kinematic deviations: the children with DMD had an increased knee flexion angle during swing (p = 0.0006). Observed gait deviations that were not reported in the review were an increased hip flexion angle during stance (p = 0.0009) and swing (p = 0.0001), altered combined knee and ankle torques (p = 0.0002), and decreased power absorption during stance (p = 0.0001). No relationships between weakness and these gait deviations were found. We were not able to replicate the gait deviations in DMD previously reported in literature, thus DMD gait remains undefined. Further, weakness does not seem to be linearly related to altered gait features. The progressive nature of the disease requires larger study populations and longitudinal analyses to gain more insight into DMD gait and its underlying causes. Copyright © 2018 Elsevier B.V. All rights

  18. The CIPM list of recommended frequency standard values: guidelines and procedures

    NASA Astrophysics Data System (ADS)

    Riehle, Fritz; Gill, Patrick; Arias, Felicitas; Robertsson, Lennart

    2018-04-01

    A list of standard reference frequency values (LoF) of quantum transitions from the microwave to the optical regime has been recommended by the International Committee for Weights and Measures (Comité international des poids et mesures, CIPM) for use in basic research, technology, and for the metrology of time, frequency and length. The CIPM LoF contains entries that are recommended as secondary representations of the second in the International System of Units, and entries that can be used to serve as realizations of the definition of the metre. The historical perspective that led to the CIPM LoF is outlined. Procedures have been developed for updating existing, and validating new, entries into the CIPM LoF. The CIPM LoF might serve as an entry for a future redefinition of the second by an optical transition.

  19. Prognostic value of heart rate variability footprint and standard deviation of average 5-minute intrinsic R-R intervals for mortality in cardiac resynchronization therapy patients.

    PubMed

    Gilliam, F Roosevelt; Singh, Jagmeet P; Mullin, Christopher M; McGuire, Maureen; Chase, Kellie J

    2007-10-01

    Cardiac resynchronization therapy devices provide effective therapy for heart failure. Heart rate variability (HRV) parameters in the device such as HRV footprint and SD of average 5-minute intrinsic R-R intervals (SDANN) are related to autonomic function and may be used to identify patients with a higher risk of mortality. We examined the relationship between HRV and mortality in a prospective cohort study. The 842 patients (mean age, 67.7 +/- 11.2; 23.5 % female; New York Heart Association class III, 88.6%; class IV, 11.4%) included in the analysis were implanted with a cardiac resynchronization therapy with defibrillation device and had baseline HRV measurements available. During a median of 11.6 months of follow-up, 7.8% (66/842) of patients died. Heart rate variability footprint and SDANN were significant predictors of mortality (all P < .05); patients with lower HRV values were at greater risk for death, compared with patients with higher HRV values. Heart rate variability changes over time tended to predict the risk of mortality in follow-up (P = nonsignificant); patients with low baseline HRV and small changes in HRV during the follow-up period were at the highest risk for death (7% mortality for SDANN and 8.9% for HRV footprint), and patients with high baseline HRV and large changes in HRV were at the lowest risk (1.5% mortality for SDANN and 2.4% for HRV footprint). Results were consistent when adjusted for age, sex, body mass index, and diastolic blood pressure. Continuously measured device HRV parameters provide prognostic information about patient mortality that may be helpful for risk stratification.

  20. Finite-time and finite-size scalings in the evaluation of large-deviation functions: Numerical approach in continuous time.

    PubMed

    Guevara Hidalgo, Esteban; Nemoto, Takahiro; Lecomte, Vivien

    2017-06-01

    Rare trajectories of stochastic systems are important to understand because of their potential impact. However, their properties are by definition difficult to sample directly. Population dynamics provides a numerical tool allowing their study, by means of simulating a large number of copies of the system, which are subjected to selection rules that favor the rare trajectories of interest. Such algorithms are plagued by finite simulation time and finite population size, effects that can render their use delicate. In this paper, we present a numerical approach which uses the finite-time and finite-size scalings of estimators of the large deviation functions associated to the distribution of rare trajectories. The method we propose allows one to extract the infinite-time and infinite-size limit of these estimators, which-as shown on the contact process-provides a significant improvement of the large deviation function estimators compared to the standard one.