Sample records for valve conduit xenograft

  1. Long-Term Survival and Freedom From Reoperation After Placement of a Pulmonary Xenograft Valved Conduit.

    PubMed

    Alfieris, George M; Swartz, Michael F; Lehoux, Juan; Bove, Edward L

    2016-08-01

    The optimal choice for pulmonary valve replacement (PVR) remains controversial. This study hypothesized that xenografts used for PVR would result in prolonged long-term survival and freedom from reoperation. Children and adults with congenital heart disease requiring PVR using a xenograft from 1980 to 1985 were reviewed. In all cases, the xenograft valve was either sewn or manufactured into a Dacron conduit, and the conduit was sewn to the pulmonary artery bifurcation. Clinical data were analyzed, and survival and freedom from reoperation were determined using Kaplan-Meier analysis. Twenty-four patients received a xenograft for PVR at 14.6 ± 5.6 years. Conduit size ranged from 21 to 27 mm. Most patients received a Carpentier-Edwards valved conduit (n = 17), followed by a Hancock valved conduit (n = 5) and an Ionescu-Shiley valve sewn into a Dacron graft (n = 2). No perioperative deaths occurred. Reoperation was required mainly for pulmonary stenosis (72.7%), followed by pulmonary insufficiency (18.2%), or both stenosis and insufficiency (9%). Freedom from reoperation was 90%, 56%, 43%, and 14% at 10, 20, 25, and 30 years, respectively. At most recent follow-up the was only death, which was related to severe biventricular failure 25 years after conduit implant. PVR using a xenograft valved conduit results in prolonged freedom from reoperation and excellent long-term survival. These data, which provide long-term follow-up information on xenograft valves after PVR. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. The Hancock® Valved Conduit for Right Ventricular Outflow Tract Reconstruction in Sheep for Assessing New Devices.

    PubMed

    Carney, John P; Zhang, Lindsey M; Larson, Jeffrey J; Lahti, Matthew T; Robinson, Nicholas A; Dalmasso, Agustin P; Bianco, Richard W

    2017-07-01

    Xenograft conduits have been used successfully to repair congenital heart defects, but are prone to failure over time. Hence, in order to improve patient outcomes, better xenografts are being developed. When evaluating a conduit's performance and safety it must first be compared against a clinically available control in a large animal model. The study aim was to evaluate a clinically available xenograft conduit used in right ventricular outflow tract (RVOT) reconstruction in a sheep model. RVOT reconstruction was performed in 13 adult and juvenile sheep, using the Medtronic Hancock® Bioprosthetic Valved Conduit (Hancock conduit). The method had previously been used on patients, and a newly modified variant termed 'RVOT Extraction' was employed to facilitate the surgical procedure. Animals were monitored over predetermined terms of 70 to 140 days. Serial transthoracic echocardiography, intracardiac pressure measurements and angiography were performed. On study completion the animals were euthanized and necropsies performed. Two animals died prior to their designated study term due to severe valvular stenosis and distal conduit narrowing, respectively. Thus, 11 animals survived the study term, with few or no complications. Generally, maximal and mean transvalvular pressure gradients across the implanted conduits were increased throughout the postoperative course. Among 11 full-term animals, seven conduits were patent with mild or no pseudointimal proliferation and with flexible leaflets maintaining the hemodynamic integrity of the valve. RVOT reconstruction using the Hancock conduit was shown to be successful in sheep, with durable and efficient performances. With its extensive clinical use in patients, and ability for long-term use in sheep (as described in the present study) it can be concluded that the Hancock conduit is an excellent control device for the evaluation of new xenografts in future preclinical studies.

  3. Sustained Improvement in Right Ventricular Chamber Dimensions 10 Years Following Xenograft Pulmonary Valve Replacement.

    PubMed

    Schubmehl, Heidi B; Swartz, Michael F; Atallah-Yunes, Nader; Wittlieb-Weber, Carol; Pratt, Rebecca E; Alfieris, George M

    2017-01-01

    The goals following pulmonary valve replacement (PVR) are to optimize right ventricular hemodynamics and minimize the need for subsequent reoperations on the right ventricular outflow tract. We hypothesized PVR using a xenograft valved conduit would result in superior freedom from reoperation with sustained improvement in right ventricular chamber dimensions. Xenograft valved conduits placed in patients aged >16 years were reviewed from 2000 to 2010 to allow for a 5-year minimum follow-up. Preoperative, one-year, and the most recent echocardiograms quantified right ventricular chamber dimensions, corresponding Z scores, and prosthetic valve function. Magnetic resonance imaging (MRI) studies compared preoperative and follow-up right ventricular volumes. A total of 100 patients underwent PVR at 24 (19-34) years. Freedom from reintervention was 100% at 10 years. At most recent follow-up, only one patient had greater than mild pulmonary insufficiency. The one-year (17.3 ± 7.2 mm Hg; P < .01) and most recent follow-up (18.6 ± 9.8 mm Hg; P < .01) Doppler-derived right ventricular outflow tract gradients remained significantly lower than preoperative measurements (36.7 ± 27.0 mm Hg). Similarly, right ventricular basal diameter, basal longitudinal diameter, and the corresponding Z scores remained lower at one year and follow-up from preoperative measurements. From 34 MRI studies, the right ventricular end-diastolic indexed volume (161.7 ± 58.5 vs 102.9 ± 38.3; P < .01) and pulmonary regurgitant fraction (38.0% ± 15.9% vs 0.8% ± 3.3%; P < .01) were significantly lower at 7.1 ± 3.4 years compared to the preoperative levels. Use of a xenograft valved conduit for PVR results in excellent freedom from reoperation with sustained improvement in right ventricular dimensions at an intermediate-term follow-up.

  4. Initial experience with xenograft bioconduit for the treatment of complex prosthetic valve endocarditis.

    PubMed

    Roubelakis, Apostolos; Karangelis, Dimos; Sadeque, Syed; Yanagawa, Bobby; Modi, Amit; Barlow, Clifford W; Livesey, Steven A; Ohri, Sunil K

    2017-07-01

    The treatment of complex prosthetic valve endocarditis (PVE) with aortic root abscess remains a surgical challenge. Several studies support the use of biological tissues to minimize the risk of recurrent infection. We present our initial surgical experience with the use of an aortic xenograft conduit for aortic valve and root replacement. Between October 2013 and August 2015, 15 xenograft bioconduits were implanted for complex PVE with abscess (13.3% female). In 6 patients, concomitant procedures were performed: coronary bypass (n=1), mitral valve replacement (n=5) and tricuspid annuloplasty (n=1). The mean age at operation was 60.3±15.5 years. The mean Logistic European system for cardiac operating risk evaluation (EuroSCORE) was 46.6±23.6. The median follow-up time was 607±328 days (range: 172-1074 days). There were two in-hospital deaths (14.3% mortality), two strokes (14.3%) and seven patients required permanent pacemaker insertion for conduction abnormalities (46.7%). The mean length of hospital stay was 26 days. At pre-discharge echocardiography, the conduit mean gradient was 9.3±3.3mmHg and there was either none (n=6), trace (n=6) or mild aortic insufficiency (n=1). There was no incidence of mid-term death, prosthesis-related complications or recurrent endocarditis. Xenograft bioconduits may be safe and effective for aortic valve and root replacement for complex PVE with aortic root abscess. Although excess early mortality reflects the complexity of the patient population, there was good valve hemodynamics, with no incidence of recurrent endocarditis or prosthesis failure in the mid-term. Our data support the continued use and evaluation of this biological prosthesis in this high-risk patient cohort.

  5. Modified Ross procedure using a conduit with a synthetic valve.

    PubMed

    Takabayashi, Shin; Kado, Hideaki; Shiokawa, Yuichi; Fukae, Kouji; Nakano, Toshihide

    2004-12-01

    In the Ross procedure, a homograft conduit is commonly used in place of an autotransplanted pulmonary valve. Homograft availability may be a problem and has resulted in a search for alternatives. We performed a modified Ross procedure for right ventricular outflow tract reconstruction with a synthetic valved conduit as an alternative to homograft. Our early results of valvular and right ventricular function were evaluated in patients who used a conduit with a synthetic valve. Subjects consisted of 11 patients, who ranged in age from 5 to 22 years (12.0+/-4.9), and whose body weight ranged from 15.1 to 52.5 (34.3+/-14.4) kg. Indications for surgery were aortic stenosis (n=3), aortic stenosis and regurgitation (n=4), and aortic regurgitation (n=4). Right ventricular outflow tract reconstruction was performed using a hand-fashioned valved conduit prepared by sewing a 0.1 mm thick polytetrafluoroethylene sheet onto the luminal cavity of the 20-28 mm conduit. A conduit made with polytetrafluoroethylene was used in 8 patients, and a Dacron graft was used in 3 patients. There was no in-hospital or late mortality and angiocardiography at discharge revealed that all artificial valves remained active. The mean right atrial pressure and right ventricular end-diastolic pressure were not statistically different from preoperative values. The latest echocardiography (mean interval, 12.6 months) revealed that a mean pressure gradient across the synthetic valve was 11.4+/-11.1 mmHg and none of the patients had moderate or severe regurgitation. We demonstrated that a modified Ross procedure for right ventricular outflow tract reconstruction using a conduit with an appropriate synthetic valve is particularly effective in older children.

  6. [Experimental studies of original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica)].

    PubMed

    Murakami, T

    1989-05-01

    Extracardiac conduits, such as Dacron or homo-graft, have been utilized for the operative management of many patients with congenital right ventricular outflow obstruction. However, they have been recognized to become obstructed or calcified with time. As a new material for extracardiac conduit, an original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica) was investigated. Various types of valved conduit were evaluated for the hydrodynamics by a circulation system. A flow-pressure gradient Lissajous was used for the evaluation. The conduit of 10 mm in diameter had a high resistance to flow. The monocusp-valved conduit had a diastolic regurgitation (DR) at any given pressures and heart rates. The bicusp-valved conduit had a DR at higher heart rates (greater than 153/min). In this experiment, the tricusp-valved conduit with a valvular vertical versus horizontal length ratio of 2:3 had utmost favorable results under any given conditions. The valved conduits were also evaluated using sixteen mongrel dogs in which the conduit were used for the reconstruction of continuity between right ventricle and pulmonary artery. Five dogs died of bacterial infection or thrombotic obstruction. Following hemodynamic studies, which were performed in eleven dogs 1, 6, and 12 months after the operation, the dogs were sacrificed to evaluate the histological changes in the conduits. The valvular function had been satisfactory until one month, however, it was lost in 6 months because the valvular leaflets were covered with neointimae grown over them. Thin neointimae were observed both at the sites of anastomosis and at the base of the valves in dogs sacrificed at one month. They spread from the proximal anastomotic site to distal one. They were organized and it was hard to remove them manually. Thrombi were found in six dogs at the proximal anastomotic site with intimal hyperplasia. There was no calcification in Xenomedica and its degenerative change was

  7. Small-sized conduits in the right ventricular outflow tract in young children: bicuspidalized homografts are a good alternative to standard conduits.

    PubMed

    François, Katrien; De Groote, Katya; Vandekerckhove, Kristof; De Wilde, Hans; De Wolf, Daniel; Bové, Thierry

    2017-10-03

    Downsizing a homograft (HG) through bicuspidalization has been used for more than 2 decades to overcome the shortage of small-sized conduits for reconstruction of the right ventricular outflow tract (RVOT) in young children. Our goal was to investigate the durability of bicuspidalized HGs compared with other small HGs. A retrospective analysis of 93 conduits ≤20 mm, implanted over 23 years, was performed. The end-points were survival, structural valve degeneration and conduit replacement. The conduits comprised 40 pulmonary HGs, 12 aortic HGs, 17 bicuspidalized HGs and 24 xenografts. The median age, mean conduit diameter and z-value at implantation were 1.4 (interquartile range 0.3-3) years, 16.5 ± 2.7 mm and 2.8 ± 1.3, respectively. Valve position was heterotopic in 59 patients and orthotopic in 34 patients. At a mean follow-up period of 7.6 ± 5.9 years, the hospital survival rate was 89%. Freedom from explant at 5 and 10 years was 83 ± 5% and 52 ± 6%, respectively. Freedom from structural valve degeneration was 79 ± 5% at 5 years and 47 ± 6% at 10 years [68 ± 8% for pulmonary HG, 42 ± 16% for bicuspidalized HG, 31 ± 15% for aortic HG and 20 ± 9% for xenografts (log rank P < 0.001)]. Multivariable analysis indicated an increased risk for structural valve degeneration with smaller conduit size (hazard ratio 0.79, 95% confidence interval 0.67-0.94; P < 0.008), extra-anatomic position (hazard ratio 2.71, 95% confidence interval 1.33-5.50; P = 0.006) and the use of xenografts compared with non-downsized pulmonary HGs (hazard ratio 4.90, 95% confidence interval 2.23-10.76; P < 0.001). Appropriately sized pulmonary HGs remain the most durable option for a right ventricular outflow tract conduit in young children. However, when a small pulmonary HG is unavailable, bicuspidalization offers a valid alternative, preferable to xenograft conduits, at mid-term follow-up. © The Author

  8. A valved hepatic portoduodenal intestinal conduit for biliary atresia.

    PubMed

    Tanaka, K; Shirahase, I; Utsunomiya, H; Katayama, T; Uemoto, S; Asonuma, K; Inomata, Y; Ozawa, K

    1991-03-01

    Forty-six consecutive patients with biliary atresia were operated on at our institution during the 11-year period between 1978 and 1989. Their ages at operation ranged from 18 to 153 days (mean, 59 days). After dissecting the porta hepatis structures by Kasai operation, a biliointestinal anastomosis was constructed with a valved hepatic portoduodenal intestinal conduit in all cases. The intestinal valve is an intussuscepted muscular valve. Valvular function was examined radiologically. The upper gastrointestinal series demonstrated no reflux of contrast material into the conduit proximal to the valve and liver scintigraphy demonstrated that radioactive isotope drained readily into the duodenum through the valve. Thirty-nine of the forty-six patients (85%) had bile drainage after initial operation. At present 30 patients (65%) are alive without jaundice, 6 (13%) are alive with jaundice, and 10 (22%) are dead. The 5-year jaundice-free survival rate was 64%. Cholangitis occurred in 9 of 39 patients (23%) who had obtained apparent bile drainage: 5 had tractable cholangitis and 4 had refractory cholangitis. Reoperation restored bile flow in 2 of 8 patients who abruptly ceased to have bile drainage without cholangitis. In conclusion, with a valved hepatic portoduodenal intestinal conduit, the incidence of cholangitis was decreased, its medical control became easier, and the survival rate was improved.

  9. Treatment of aortic stenosis with aortic valve bypass (apicoaortic conduit) surgery: an assessment using computational modeling.

    PubMed

    Balaras, Elias; Cha, K S; Griffith, Bartley P; Gammie, James S

    2009-03-01

    Aortic valve bypass surgery treats aortic valve stenosis with a valve-containing conduit that connects the left ventricular apex to the descending thoracic aorta. After aortic valve bypass, blood is ejected from the left ventricle via both the native stenotic aortic valve and the conduit. We performed computational modeling to determine the effects of aortic valve bypass on aortic and cerebral blood flow, as well as the effect of conduit size on relative blood flow through the conduit and the native valve. The interaction of blood flow with the vascular boundary was modeled using a hybrid Eurelian-Lagrangian formulation, where an unstructured Galerkin finite element method was coupled with an immersed boundary approach. Our model predicted native (stenotic) valve to conduit flow ratios of 45:55, 52:48, and 60:40 for conduits with diameters of 20, 16, and 10 mm, respectively. Mean gradients across the native aortic valve were calculated to be 12.5, 13.8, and 17.6 mm Hg, respectively. Post-aortic valve bypass cerebral blood flow was unchanged from preoperative aortic valve stenosis configurations and was constant across all conduit sizes. In all cases modeled, cerebral blood flow was completely supplied by blood ejected across the native aortic valve. An aortic valve bypass conduit as small as 10 mm results in excellent relief of left ventricular outflow tract obstruction in critical aortic valve stenosis. The presence of an aortic valve bypass conduit has no effect on cerebral blood flow. All blood flow to the brain occurs via antegrade flow across the native stenotic valve; this configuration may decrease the long-term risk of cerebral thromboembolism.

  10. Opening and closing characteristics of the aortic valve after valve-sparing procedures using a new aortic root conduit.

    PubMed

    De Paulis, R; De Matteis, G M; Nardi, P; Scaffa, R; Buratta, M M; Chiariello, L

    2001-08-01

    The durability of aortic valve-sparing procedures is negatively affected by increased leaflet stress in the absence of normally shaped sinuses of Valsalva. We compared valve motion after remodeling procedures using a standard conduit and a specifically designed aortic root conduit. Echocardiographic studies of the aortic valve dynamics were performed in 14 patients after remodeling of the aortic root (7 standard conduits, group A; 7 new conduits, group B) and in 7 controls (group C). Opening and closing leaflet velocities and percent of slow closing leaflet displacement were measured. Root distensibility and the pressure strain of the elastic modulus were measured at all root levels. Root distensibility and the pressure strain of the elastic modulus were different in group A and B only at the sinuses (p < 0.001). Opening and closing leaflet velocities were not different among groups. Slow closing leaflet displacement was markedly more evident in group B patients (24.2%+/-1.9% versus 2.5%+/-1.9% in group A, p < 0.001) and similar to controls (22.1%+/-7.9%). The new conduit guarantees dynamic features of the aortic valve leaflets superior to those obtained with standard conduits and more similar to normal subjects.

  11. Midterm performance of a novel restorative pulmonary valved conduit: preclinical results.

    PubMed

    Soliman, Osama I; Miyazaki, Yosuke; Abdelghani, Mohammad; Brugmans, Marieke; Witsenburg, Maarten; Onuma, Yoshinobu; Cox, Martijn; Serruys, Patrick W

    2017-12-08

    The Xeltis bioabsorbable pulmonary valved conduit (XPV), designed to guide functional restoration of patients' own tissue, is potentially more durable than current pulmonary bioprosthetic valves/valved conduits. The aim of this study was to assess the haemodynamic performance of the novel XPV implanted in an ovine model. The XPV was surgically implanted in adult sheep under general anaesthesia and cardiopulmonary bypass (XPV group, n=20). Sheep that received a Hancock bioprosthetic pulmonary valved conduit served as a control group (HPV group, n=3). Transthoracic echocardiograms from VARC-2 recommended time points at 3, 6, 9, 12, 18 and 24 months (XPV group) and at 3 and 6 months (HPV group) after the procedure were analysed in an independent core laboratory. The primary endpoint was favourable valved conduit performance, defined as peak systolic pressure gradient <40 mmHg, no severe pulmonary regurgitation (PR), and a maximum conduit patency index of -20%. In the latter, negative values denote luminal narrowing and vice versa. The valvular peak systolic pressure gradient (mmHg) was 25.6±9.7 (3 months), 19.6±7.1 (6 months), 10.0±9.2 (24 months) in the XPV group and 18.4±6.6 (3 months), 17.7±4.6 (6 months) in the HPV group. The patency index (%) of the conduit at the valvular level was +30.3±13.6 (6 months) and +64.1±1.4 (24 months) in the XPV group and +2.0±15.9 (6 months) in the HPV group. PR was trace or mild at all visits, except in one animal with persistent moderate PR in the XPV group, up to 24 months. The XPV showed a favourable and durable haemodynamic performance (up to two years after implantation), without conduit narrowing/obstruction or severe regurgitation.

  12. Development and evaluation of a pliable biological valved conduit. Part II: Functional and hemodynamic evaluation.

    PubMed

    Sung, H W; Witzel, T H; Hata, C; Tu, R; Shen, S H; Lin, D; Noishiki, Y; Tomizawa, Y; Quijano, R C

    1993-04-01

    Many congenital cardiac malformations may require a valved conduit for the reconstruction of the right ventricular outflow tract. In spite of many endeavors made in the last 25 years, the clinical results of right ventricular outflow tract reconstruction with currently available valved conduits are still not satisfactory. Specific problems encountered clinically include suboptimal hemodynamic performance, conduit kinking or compression, and fibrous peeling from the luminal surface. To address these deficiencies, we undertook the development of a biological valved conduit: a bovine external jugular vein graft with a retained native valve cross-linked with a diglycidyl ether (DE). This study, using a canine model, was to evaluate the functional and hemodynamic performance of this newly developed valved conduit. Three 14 mm conduits, implanted as bypass grafts, right ventricle to pulmonary artery, were evaluated. The evaluation was conducted with a noninvasive color Doppler flow mapping system at pre-implantation, immediately post implantation, one- and three-months post implantation, and prior to retrieval (five-months post implantation). The two-dimensional tomographic inspection of the leaflet motion at various periods post implantation showed that the valvular leaflets in the DE treated conduit was quite pliable. No cardiac failure or valvular dysfunction was observed in any of the studied cases. The color Doppler flow mapping study demonstrated that the valve in the DE treated conduit was competent, with no conduit kinking or compression observed in any of the three cases. The spectral Doppler velocity study evidenced that the transvalvular pressure gradients of the DE treated conduit were minimal as compared to those of the currently available conduits. In conclusion, from the functional and hemodynamic performance points of view, this newly developed valved conduit is superior to those currently available.

  13. The bovine jugular vein: a totally integrated valved conduit to repair the right ventricular outflow.

    PubMed

    Carrel, Thierry; Berdat, Pascal; Pavlovic, Mladen; Pfammatter, Jean-Pierre

    2002-07-01

    Current techniques to correct valvular anomalies of the right ventricular outflow tract (RVOT) include repair and replacement of the pulmonary valve. However, the performance of currently used conduits has been less than ideal because of unfavorable hemodynamics and mid- to long-term complications. An early experience with a totally integrated Contegra valved conduit derived from a bovine jugular vein is reported; this conduit has the advantage that there is no discontinuity between its lumen and the valve it incorporates. Between October 1999 and October 2001, a total of 22 Contegra valved conduits (12-22 mm) was implanted in 21 children aged <5 years, and in one patient aged 21 years. Diagnosis included tetralogy of Fallot (n = 13), pulmonary atresia (n = 3), double outlet right ventricle with pulmonary stenosis (PS) (n = 3), transposition of the great arteries, ventricular septal defect and PS (n = 2) and truncus arteriosus (n = 1). In 15 of these patients, distal and proximal anastomoses were performed on the beating heart. There was no mortality and no valved-conduit-related early morbidity. Intraoperative invasive assessment demonstrated excellent hemodynamic characteristics: mean peak pressure increase was 8.5+/-6.3 mmHg (varying between 4 mmHg in the 20-mm conduit and 18 mmHg in the 14-mm conduit). These values were confirmed by pre-discharge transthoracic pulsed-wave Doppler echocardiography. Because of endocarditis, one conduit was explanted after 11 months and replaced with a pulmonary homograft. Two patients required reintervention. The Contegra valved conduit is an excellent immediate substitute in the treatment of RVOT lesion when a pulmonary valve has to be inserted. Both systolic and diastolic valve functions are promising. Further data are required to confirm the favorable hemodynamics, as well as the durability and efficacy of this conduit in the long term.

  14. Aortic valve replacement with the Biocor PSB stentless xenograft.

    PubMed

    Bertolini, P; Luciani, G B; Vecchi, B; Pugliese, P; Mazzucco, A

    1998-08-01

    The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and

  15. Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience

    PubMed Central

    2011-01-01

    Objectives To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. Methods Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. Results Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). Conclusions The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade. PMID:21699696

  16. 3D Bioprinting of Heterogeneous Aortic Valve Conduits with Alginate/Gelatin Hydrogels

    PubMed Central

    Duan, Bin; Hockaday, Laura A.; Kang, Kevin H.; Butcher, Jonathan T.

    2013-01-01

    Heart valve disease is a serious and growing public health problem for which prosthetic replacement is most commonly indicated. Current prosthetic devices are inadequate for younger adults and growing children. Tissue engineered living aortic valve conduits have potential for remodeling, regeneration, and growth, but fabricating natural anatomical complexity with cellular heterogeneity remain challenging. In the current study, we implement 3D bioprinting to fabricate living alginate/gelatin hydrogel valve conduits with anatomical architecture and direct incorporation of dual cell types in a regionally constrained manner. Encapsulated aortic root sinus smooth muscle cells (SMC) and aortic valve leaflet interstitial cells (VIC) were viable within alginate/gelatin hydrogel discs over 7 days in culture. Acellular 3D printed hydrogels exhibited reduced modulus, ultimate strength, and peak strain reducing slightly over 7-day culture, while the tensile biomechanics of cell-laden hydrogels were maintained. Aortic valve conduits were successfully bioprinted with direct encapsulation of SMC in the valve root and VIC in the leaflets. Both cell types were viable (81.4±3.4% for SMC and 83.2±4.0% for VIC) within 3D printed tissues. Encapsulated SMC expressed elevated alpha-smooth muscle actin when printed in stiff matrix, while VIC expressed elevated vimentin in soft matrix. These results demonstrate that anatomically complex, heterogeneously encapsulated aortic valve hydrogel conduits can be fabricated with 3D bioprinting. PMID:23015540

  17. Long-term follow-up of autologous pericardial valved conduits.

    PubMed

    Schlichter, A J; Kreutzer, C; Mayorquim, R C; Simon, J L; Vazquez, H; Roman, M I; Kreutzer, G O

    1996-07-01

    The aim of this study was to evaluate the long-term results of the use of an autologous pericardial valved conduit in the outflow tract of the venous ventricle in congenital heart malformations. Fifty-one patients were followed up for a period of 12 to 120 months; 30 for more than 36 months and 13 for more than 72 months. All were evaluated clinically and by two-dimensional and Doppler echocardiography. Eight patients were recatheterized. Postoperative evaluation included serial measurement of pressure gradients and the conduit's diameter at the proximal, valvular, and distal levels. Reoperation because of stenosis was indicated when the gradient across the right ventricular outflow was greater than 50 mm Hg. The reoperation rate in relation with postoperative time, diameter of the autologous pericardial valved conduit at the time of implantation, and malformation was statistically analyzed. In 27 patients the conduit increased its diameter 1 to 7 mm. In 20 patients the diameter remained unchanged, whereas a reduction was noted in 4. Conduit survival free of reoperation for the whole group was 89.9% at 5 years. Conduit survival free of reoperation was 100% at 5 and 7 years for conduits larger than 16 mm at the time of implantation. It was 95% (standard deviation = 4.8%) at 5 years and 72.3% at 7 years for those 16 mm or less. For patients operated after January 1, 1986 (technical modification), conduit survival free of reoperation was 95.4% at 7 years postoperatively. These results compare favorably with those of other available conduits.

  18. Effect of valsalva in the pulmonary prosthetic conduit valve on hemodynamic function in a mock circulatory system.

    PubMed

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Matsuo, Satoshi; Saiki, Yoshikatsu; Yamagishi, Masaaki

    2015-01-01

    Pulmonary conduit valves are used as one of the surgical treatment methods of congenital heart diseases. We have been designing a sophisticated pulmonary conduit valve for the right ventricular outflow tract reconstruction in pediatric patients. In this study, two types of polyester grafts with or without bulging structures for the conduit valves were used and evaluated from the hemodynamic point of view focusing on the application of these conduit valves in the grown-up congenital heart failure patients. We examined valvular function in the originally developed pulmonary mock circulatory system, which consisted of a pneumatic driven right ventricular model, a pulmonary valve chamber, and an elastic pulmonary compliance model with peripheral vascular resistance units. Prior to the measurement, a bileaflet valve was sutured in each conduit. Each conduit valve was installed in the mock right ventricular outflow portion, and its leaflet motion was obtained by using a high-speed camera synchronously with pressure and flow waveforms. As a result, we could obtain hemodynamic changes in two different types of conduits for pulmonary valves, and it was indicated that the presence of the Valsalva shape might be effective for promoting valvular response in the low cardiac output condition.

  19. Three-dimensional printed trileaflet valve conduits using biological hydrogels and human valve interstitial cells.

    PubMed

    Duan, B; Kapetanovic, E; Hockaday, L A; Butcher, J T

    2014-05-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement, capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, three-dimensional (3-D) bioprinting enables deposition of cells and hydrogels into 3-D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach, however, is constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not known how human valve cells respond to these printed environments. In this study, 3-D printable formulations of hybrid hydrogels are developed, based on methacrylated hyaluronic acid (Me-HA) and methacrylated gelatin (Me-Gel), and used to bioprint heart valve conduits containing encapsulated human aortic valvular interstitial cells (HAVIC). Increasing Me-Gel concentration resulted in lower stiffness and higher viscosity, facilitated cell spreading, and better maintained HAVIC fibroblastic phenotype. Bioprinting accuracy was dependent upon the relative concentrations of Me-Gel and Me-HA, but when optimized enabled the fabrication of a trileaflet valve shape accurate to the original design. HAVIC encapsulated within bioprinted heart valves maintained high viability, and remodeled the initial matrix by depositing collagen and glyosaminoglycans. These findings represent the first rational design of bioprinted trileaflet valve hydrogels that regulate encapsulated human VIC behavior. The use of anatomically accurate living valve scaffolds through bioprinting may accelerate understanding of physiological valve cell interactions and progress towards de novo living valve replacements. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. The evolution of a valved hepatoduodenal intestinal conduit.

    PubMed

    Kaufman, B H; Luck, S R; Raffensperger, J G

    1981-06-01

    Ascending cholangitis remains among the most serious complications following operations for biliary disorders. The bacterial count of refluxing intestinal contents can be reduced by using an enteric conduit from the biliary tract to the relatively sterile duodenum. A valvular conduit prohibits reflux of intestinal contents and permits unobstructed antegrade flow of bile. This can be created by intussuscepting approximately 1 cm of intestine in the midportion of the conduit. During the last 3 yr, valvular conduits were created in 11 patients. Seven of these children were treated for biliary atresia, and 4 had operations for choledochal duct cysts. There have been no deaths or morbidity resulting from the use of the valvular conduits. The postoperative courses in these patients indicate that the use of an intussusception valve may be beneficial in the prevention of ascending cholangitis.

  1. The performance of Hancock porcine-valved Dacron conduit for right ventricular outflow tract reconstruction.

    PubMed

    Belli, Emre; Salihoğlu, Ece; Leobon, Bertrand; Roubertie, François; Ly, Mohammed; Roussin, Régine; Serraf, Alain

    2010-01-01

    The surgical reconstruction of right ventricle outflow tract (RVOT) often requires the implantation of a valved conduit. Homografts are lacking availability and are associated with limited durability in children. Our experience with the Hancock porcine-valved Dacron (DuPont, Wilmington, DE) conduit (Medtronic, Minneapolis, MN) was retrospectively assessed. Follow-up was studied in 214 survivors who underwent 247 conduit implants between January 1990 and January 2007. Pulmonary atresia/ventricular septal defect was present in 86 (40.2%) and truncus arteriosus in 62 (29%). Conduit implantation was associated with anatomic repair in 136, conduit replacement in 96, and secondary pulmonary valve insertion in 15. Median age at operation was 62.5 months (range, 1 week to 50 years), including 14 neonates (6%). Median conduit size was 17.4 mm because of routine over-sizing. Pulmonary bifurcation patch augmentation was necessary in 26 patients. Periodic echocardiography studies were performed for a median follow-up of 98 months (range, 13 to 142 months). Three (1.4%) late deaths occurred. No conduit-related deaths or complications occurred. Conduit degeneration was associated with increase in valvular gradient. Valve regurgitation was absent or mild. Higher RVOT systolic pressure gradient at discharge did not influence conduit longevity. Conduit reoperation was delayed due to percutaneous balloon dilatation in 14 patients, associated with stenting in 7. Survival with freedom from conduit reoperation was 98% (95% confidence interval [CI], 97% to 100%) at 1 year, 81% (95% CI, 75% to 87%) at 5 years, and 32% (95% CI, 22% to 42%) at 10 years. The Hancock valved conduit is a safe and reliable alternative to homografts. It appears to be appropriate in patients with limited pulmonary vascular bed and high pulmonary artery pressures. Caution is required in neonates because of the rigidity of the Dacron housing. Initial results with secondary percutaneous procedures are encouraging

  2. [Development and evaluation of a prosthetic valved conduit dilated by percutaneous approach: experimental study in the lamb].

    PubMed

    Boudjemline, Y; Laborde, F; Pineau, E; Mollet, A; Abadir, S; Bonhoeffer, P; Bonnet, D; Sidi, D

    2006-05-01

    This study was undertaken to develop a dilated valved conduit for reconstruction of the right ventricular outflow tract in the animal. The conduits were made by sewing a valved tube (Medtronic Inc) inside a vascular stent (Numed Inc). After preparation, they were inserted surgically in five lambs. The conduits were then dilated 6 weeks and 3 months after their implantation. Before sacrificing the animals at 3 months, a 22 mm valved stent was implanted percutaneously inside the surgical conduits. One animal died suddenly due to kinking of the conduit. Balloon dilatation was performed in the surviving animals. The first dilatation only had a modest impact on valvular function but it was much aggravated after the second dilatation. A valved stent was successfully inserted percutaneously. At sacrifice, all the conduits were completely engulfed in an intense fibrosis. In conclusion, a valved biological conduit for reconstruction of the right ventricular ejection tract has been developed and can be dilated sequentially to follow growth. The new product could have an important role to play in the management of congenital malformations involving the right ventricular outflow tract.

  3. Xenograft transplantation in congenital cardiac surgery at Baskent University: midterm results.

    PubMed

    Ozkan, S; Akay, T H; Gultekin, B; Sezgin, A; Tokel, K; Aslamaci, S

    2007-05-01

    Xenograft valved conduits have been used in several cardiac pathologies. In this study we have presented our midterm results of pediatric patients pathologies who were operated with xenograft conduits. Between January 1999 and January 2005, 134 patients underwent open heart surgery with xenograft conduits. The conduits were used to establish the continuity of the right ventricle to the pulmonary artery or aorta, the left ventricle to the pulmonary artery, or aorta due to various types of complex cardiac anomalies. Patients were evaluated by transthoracic echocardiography (ECHO) at 6-month follow-ups. Cardiac catheterization was performed when ECHO demonstrated significant conduit failure. Hospital mortality was observed in 28 patients (20.1%), and 13 patients died upon follow-up (9.7%). Mean follow-up was 24.6 +/- 4 months (range, 13 to 85 months). Among 93 survivors 20 patients (21.5%) were reoperated due to conduit failure. The main reasons for conduit failure were stenosis (n=13), valvular regurgitation (n=2), or both conditions in 5 cases. Mean pulmonary gradient before conduit re-replacement was 47.7 +/- 30.1 mmHg. The 1-, 3-, and 6-year actuarial survival rates were 95 +/- 2%, 91 +/- 3%, and 86 +/- 5%. The 1-, 3-, and 6-year actuarial freedom rates from reoperation were 95 +/- 1%, 90 +/- 3%, and 86 +/- 4%. An increased gradient between the pulmonary artery and the right ventricle and prolonged cardiopulmonary bypass times were observed to be significant risk factors for reoperation. There was no mortality among reoperated patients. Xenograft conduits should be closely followed for calcification and stenosis. Conduit stenosis is the major risk factor for reoperation. In these patients, reoperation for conduit replacement can be performed safely before deterioration of cardiac performance.

  4. Longevity after aortic root replacement: is the mechanically valved conduit really the gold standard for quinquagenarians?

    PubMed

    Etz, Christian D; Girrbach, Felix F; von Aspern, Konstantin; Battellini, Roberto; Dohmen, Pascal; Hoyer, Alexandro; Luehr, Maximilian; Misfeld, Martin; Borger, Michael A; Mohr, Friedrich W

    2013-09-10

    The choice of the best conduit for root/ascending disease and its impact on longevity remain controversial in quinquagenarians. A total of 205 patients (men=155) between 50 and 60 years (mean, 55.7 ± 2.9 years) received either a stentless porcine xenoroot (n=78) or a mechanically valved composite prosthesis (n=127) between February 1998 and July 2011. Of these, 166 patients underwent root replacement for aneurysmal disease (porcine: 39% [n=65]; mechanical: 61% [n=101]; P=0.5), 25 for acute type A aortic dissection (porcine: 32% [n=8]; mechanical: 68% [n=17]; P=0.51), and 14 for endocarditis/iatrogenic injury involving the aortic root (6.4% [n=5] versus 7.1% [n=9]; P=1.0). The predominant aortic valve pathology was stenosis in 19% (n=38), regurgitation in 50% (n=102), combined valvular dysfunction in 26% (n=54), and normal aortic valve function in 5% (n=11). Concomitant procedures included coronary artery bypass grafting (13%), mitral valve repair (7%), and partial/complete arch replacement (12%/4%), with no significant differences between porcine and mechanical root replacement. Overall hospital mortality was 7.3%, with no difference between the 2 types of valve prostheses (7.7% for porcine and 7.1% for mechanical root replacement; P=1.0). Follow-up averaged 5.4 ± 3.7 years (1096 patient-years) and was 100% complete. Freedom from aorta-related reoperation at 12 years was not statistically different between the groups (porcine: 94.9% versus mechanical: 96.1%; P=0.73). Survival was equivalent between both groups, with a 5-year survival of 86 ± 3% (porcine: 88 ± 4%; mechanical: 85 ± 3%; P=0.96) and a 10-year survival of 76% (porcine: 80 ± 7%; mechanical: 75 ± 5%; P=0.84). The linearized mortality rate was 3.1%/patient-year (porcine: 2.9%/patient-year; mechanical: 3.2%/patient-year). In quinquagenerians, long-term survival after stentless porcine xenograft aortic root replacement is equivalent to that after a mechanical Bentall procedure. These results bring

  5. Aneurysm of the right ventricular outflow following bovine valved venous conduit insertion.

    PubMed

    Boudjemline, Younes; Bonnet, Damien; Agnoletti, Gabriella; Vouhé, Pascal

    2003-01-01

    A case of aneurysm of the right ventricular outflow tract is described after repair of tetralogy of Fallot using a Contegra supported conduit. Angiograms revealed that the aneurysm was located between the ventricular anastomosis and the proximal ring of the conduit confirming echocardiographic data. Because the conduit between the rings was not dilated, the valve was perfectly functioning. Pulmonary anastomosis was severely stenosed explaining the dilatation seen below. Conduit replacement with resection of the aneurysmal part of the failing conduit was performed. Supported conduits do not eliminate the risk of secondary dilatation below the artificial ring but preserve valvular function.

  6. Interstage evaluation of homograft-valved right ventricle to pulmonary artery conduits for palliation of hypoplastic left heart syndrome.

    PubMed

    Sandeep, Nefthi; Punn, Rajesh; Balasubramanian, Sowmya; Smith, Shea N; Reinhartz, Olaf; Zhang, Yulin; Wright, Gail E; Peng, Lynn F; Wise-Faberowski, Lisa; Hanley, Frank L; McElhinney, Doff B

    2018-04-01

    Palliation of hypoplastic left heart syndrome with a standard nonvalved right ventricle to pulmonary artery conduit results in an inefficient circulation in part due to diastolic regurgitation. A composite right ventricle pulmonary artery conduit with a homograft valve has a hypothetical advantage of reducing regurgitation, but may differ in the propensity for stenosis because of valve remodeling. This retrospective cohort study included 130 patients with hypoplastic left heart syndrome who underwent a modified stage 1 procedure with a right ventricle to pulmonary artery conduit from 2002 to 2015. A composite valved conduit (cryopreserved homograft valve anastomosed to a polytetrafluoroethylene tube) was placed in 100 patients (47 aortic, 32 pulmonary, 13 femoral/saphenous vein, 8 unknown), and a nonvalved conduit was used in 30 patients. Echocardiographic functional parameters were evaluated before and after stage 1 palliation and before the bidirectional Glenn procedure, and interstage interventions were assessed. On competing risk analysis, survival over time was better in the valved conduit group (P = .040), but this difference was no longer significant after adjustment for surgical era. There was no significant difference between groups in the cumulative incidence of bidirectional Glenn completion (P = .15). Patients with a valved conduit underwent more interventions for conduit obstruction in the interstage period, but this difference did not reach significance (P = .16). There were no differences between groups in echocardiographic parameters of right ventricle function at baseline or pre-Glenn. In this cohort of patients with hypoplastic left heart syndrome, inclusion of a valved right ventricle to pulmonary artery conduit was not associated with any difference in survival on adjusted analysis and did not confer an identifiable benefit on right ventricle function. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier

  7. The first fifty consecutive Bentall operations with a prefabricated tissue-valved aortic conduit: a single-center experience.

    PubMed

    Baraki, Hassina; Al Ahmad, Ammar; Sarikouch, Samir; Koigeldiev, Nurbol; Khaladj, Nawid; Hagl, Christian; Pichlmaier, Maximillian; Haverich, Axel; Shrestha, Malakh

    2010-05-01

    Composite replacement is the standard treatment for the repair of aortic aneurysm with aortic valve pathology. With improved long-term durability and no requirement for long-term anticoagulation, tissue-valved conduits have become increasingly popular. Herein are reported the results achieved with 50 consecutive 'Bentall' operations, using the first commercially available prefabricated stentless tissue-valved conduit (Vascutek BioValsalva). Between September 2007 and September 2009, a total of 50 patients (10 females, 40 males; mean age 65 +/- 7 years) received a BioValsalva conduit. Concomitant procedures included coronary artery bypass grafting (CABG; n = 15), other valve (n = 5), and aortic arch replacement with circulatory arrest (n = 20; three of these had an additional frozen elephant trunk). Four of the procedures were re-operations. A six-month follow up with echocardiography and clinical examination was completed in 25 patients. The 30-day mortality was 8% (4/50). Three of these patients underwent concomitant procedures. The cardiopulmonary bypass (CPB) and cross-clamp times were 178 +/- 30 min and 106 +/- 7 min, respectively. The triple-layered vascular graft proved to be hemostatic, without suture-line bleeding. Both, the initial and follow up echocardiography showed no valvular insufficiency, with a mean gradient of 13 +/- 5 mmHg. All patients were in NYHA class I-II. The BioValsalva prefabricated tissue-valved conduit showed very good early results. The ischemic time required to construct a 'home-made' stentless tissue-valved conduit was eliminated, thus reducing the cross-clamp time. The conduit also offered the hemodynamic advantages of a stentless valve.

  8. Pericardial tissue valves and Gore-Tex conduits as an alternative for right ventricular outflow tract replacement in children.

    PubMed

    Allen, Bradley S; El-Zein, Chawki; Cuneo, Betina; Cava, Joseph P; Barth, Mary Jane; Ilbawi, Michel N

    2002-09-01

    There is still no perfect conduit for reconstruction of the right ventricular outflow tract (RVOT) in children. Homografts are not always available in the appropriate size, and degenerate in a few years. This study evaluates the pericardial valve with Gore-Tex conduit as an alternative for RVOT construction. From January 1, 1993, to September 30, 1999, a pericardial tissue valve was inserted in all patients undergoing RVOT reconstruction or pulmonary valve replacement (PVR) who were large enough to accommodate a tissue valve. In patients without a native main pulmonary artery, a new technique was used to construct an RV-PA conduit out of a flat sheet of Gore-Tex, as Dacron frequently leads to stenosis. Data were collected by retrospective review, follow-up echocardiograms, and assessment by a single cardiologist. There were 48 patients, 22 undergoing a PVR alone and 26 a RV-PA valved Gore-Tex conduit. Diagnosis included tetralogy of Fallot (n = 25); truncus arteriosis (n = 9); ventricular septal defect with PA (n = 5); DORV (n = 4); D-TGA with PS (n = 2); and 1 each IAA with sub AS, VSD with PI, and PS s/p Ross procedure. Patient age ranged from 3 to 33 years and 98% were reoperations. The valve sizes ranged from 19 to 33 mm and the median hospital length of stay was 4 days. There were 2 (4.2%) perioperative and 1 (2.1%) late deaths, none related to the valve or Gore-Tex conduit. At a follow-up of 15 to 86 months (mean 43 +/- 16 months), all remaining 45 patients are New York Heart Association class I, all valves are functional, and no patient has required valve or conduit replacement or revision; more importantly, echocardiogram revealed no significant valve or conduit stenosis (mean gradient 16 +/- 8 mm Hg) and no evidence of regurgitation or structural degeneration. A pericardial tissue valve and Gore-Tex conduit provides a reliable alternative for RVOT reconstruction in pediatric patients. It is readily available, molds in the limited retrosternal space, and

  9. Assessment of Hemodynamic Conditions in the Aorta Following Root Replacement with Composite Valve-Conduit Graft.

    PubMed

    Cheng, Zhuo; Kidher, Emaddin; Jarral, Omar A; O'Regan, Declan P; Wood, Nigel B; Athanasiou, Thanos; Xu, Xiao Yun

    2016-05-01

    This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.

  10. Midterm results after aortic valve replacement with freehand stentless xenografts: a comparison of three prostheses.

    PubMed

    Luciani, G B; Bertolini, P; Vecchi, B; Mazzucco, A

    1998-06-01

    The ideal substitute for the diseased aortic valve is yet to be found. For the assessment and comparison of the midterm results after aortic valve replacement with three different types of freehand stentless xenografts, all patients who underwent the operation between October 1992 and April 1997 were reviewed. Of 231 patients undergoing aortic valve replacement, 106 patients (group 1) were given the Biocor PSB (Biocor Industria e Pesquisa Ltda, Belo Horizonte, MG, Brazil); 76 patients (group 2) were given the Toronto SPV (St. Jude Medical, Inc., St. Paul, Minn.), and 49 patients (group 3) were given the O'Brien-Angell valve (Bravo Cardiovascular model 300, Cryolife, Inc., Marietta, Ga.). The first two xenografts require inflow and outflow suturelines; the third xenograft needs a single-sutureline implantation. Mean age (70 +/- 6 years; 70 +/- 7 years; 72 +/- 9 years; p = 0.6), prevalence of male sex (56 patients, 53%; 37 patients, 49%; 22 patients, 45%; p = 0.7), of aortic stenosis (72 patients, 68%; 54 patients, 71%; 37 patients, 73%; p = 0.6), and need for associated procedures (51 patients, 48%; 30 patients, 40%; 21 patients, 43%; p = 0.1) were comparable among groups. Mean aortic crossclamp time was shorter in group 3 (96 +/- 24 minutes; 100 +/- 23 minutes; 88 +/- 25 minutes;p = 0.01). Early deaths were 3 of 106 (3%) in group 1, 2 of 76 (3%) in group 2, and 2 of 49 (4%) in group 3. Follow-up of survivors ranged from 1 to 54 months (mean 32 +/- 13 months). Survival at 4 years was 90% +/- 3% in group 1, 95% +/- 3% in group 2, 85% +/- 8% in group 3 (p = 0.3). At 4 years, freedom from valve-related events was 95% +/- 6%, 100%, 70% +/- 8% (p = 0.004), while freedom from valve deterioration was 99% +/- 1%, 100%, 73% +/- 8% (p = 0.001), in group 1, 2, and 3, respectively (p = 0.001). At follow-up, reintervention on the xenograft was necessary in one patient (endocarditis) in group 1, none in group 2, and six in group 3 (technical cause, group 3; valve tear, group 2

  11. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit

    PubMed Central

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-01-01

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable. PMID:24510692

  12. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    PubMed

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  13. CorMatrix valved conduit in a porcine model: long-term remodelling and biomechanical characterization.

    PubMed

    Mosala Nezhad, Zahra; Poncelet, Alain; de Kerchove, Laurent; Fervaille, Caroline; Banse, Xavier; Bollen, Xavier; Dehoux, Jean-Paul; El Khoury, Gebrine; Gianello, Pierre

    2017-01-01

    Porcine small intestinal submucosa extracellular matrix (CorMatrix; CorMatrix Cardiovascular, Rosewell, GA) is a relatively novel tissue substitute used in cardiovascular applications. We investigated the biological reaction and remodelling of CorMatrix as a tri-leaflet valved conduit in a pig model. We hypothesized that CorMatrix maintains a durable architecture as a valved conduit and remodels to resemble surrounding tissues. We fashioned the valved conduit using a 7 × 10 cm 4-ply CorMatrix sheet and placed it in the thoracic aorta of seven landrace pigs for 3, 4, 5 and 6 months. Biodegradation, replacement by native tissue, strength and durability were examined by histology, immunohistochemistry and mechanical testing. Four pigs, one per time frame, completed the study. The conduit lost its original architecture as a tri-leaflet valve due to cusp immobility, subsequent attachment to the wall segment and consequent maintenance of a thick arterial wall-like structure. Scaffold resorption was incomplete, with disorganized inconsistent spatial and temporal degradation even at 6 months. Fibrosis, scarring and calcification started at 4 months and chronic inflammation persisted. The partially remodelled scaffold did not resemble the aortic wall, suggesting impaired remodelling. Mechanical testing showed progressive weakening of the tissues over time, which were liable to breakage. CorMatrix is biodegradable; however, it failed to remodel in a structured and anatomical fashion in an arterial environment. Progressive mechanical and remodelling failure in this scenario might be explained by the complexity of the conduit design and the host's chronic inflammatory response, leading to early fibrosis and calcification. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.

    PubMed

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki

    2016-08-01

    The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.

  15. Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.

    PubMed

    Badiu, Catalin C; Bleiziffer, Sabine; Eichinger, Walter B; Hettich, Ina; Krane, Markus; Bauernschmitt, Robert; Lange, Rüdiger

    2011-03-01

    The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the

  16. Use of a Valved-Conduit for Exclusion of the Infected Portion in the Prosthetic Pulmonary Valve Endocarditis

    PubMed Central

    Jung, Joonho; Lee, Cheol Joo; Lim, Sang-Hyun; Choi, Ho; Park, Soo-Jin

    2013-01-01

    A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39℃) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method. PMID:23772409

  17. Noninvasive diagnosis of right-sided extracardiac conduit obstruction by combined magnetic resonance imaging and continuous-wave Doppler echocardiography.

    PubMed

    Canter, C E; Gutierrez, F R; Molina, P; Hartmann, A F; Spray, T L

    1991-04-01

    Right-sided extracardiac conduits are frequently complicated by obstruction over time. We compared the utility of two-dimensional and Doppler echocardiography and magnetic resonance imaging in the diagnosis of postoperative right-sided obstruction with cardiac catheterization and angiography in 10 patients with xenograft or homograft conduits. Correlation (r = 0.95) between continuous-wave Doppler estimates and catheter pullback pressure gradients across the conduits was excellent. Echocardiography could only visualize five of 10 conduits in their entirety. Magnetic resonance imaging visualized all conduits and showed statistically significant (kappa = 0.58) agreement with angiography in the localization and estimation of severity of a variety of right-sided obstructions in these patients. However, flow voids created by the metallic ring around xenograft valves led to a false negative diagnosis of valvular stenosis in four patients when magnetic resonance imaging was used alone. Doppler studies correctly indicated obstruction in these patients. The combination of magnetic resonance imaging studies and continuous-wave Doppler echocardiography can be useful to noninvasively evaluate right-sided obstruction in postoperative patients with right-sided extracardiac conduits.

  18. Cardiovascular effects of right ventricle-pulmonary artery valved conduit implantation in experimental pulmonic stenosis.

    PubMed

    Saida, Yuuto; Tanaka, Ryou; Fukushima, Ryuji; Hoshi, Katsuichiro; Hira, Satoshi; Soda, Aiko; Iizuka, Tomoya; Ishikawa, Taisuke; Nishimura, Taiki; Yamane, Yoshihisa

    2009-04-01

    Right ventricle (RV)-pulmonary artery (PA) valved conduit (RPVC) implantation decreases RV systolic pressure in pulmonic stenosis (PS) by forming a bypass route between the RV and the PA. The present study evaluates valved conduits derived from canine aortae in a canine model of PS produced by pulmonary artery banding (PAB). Pulmonary stenosis was elicited using PAB in 10 conditioned beagles aged 8 months. Twelve weeks after PAB, the dogs were assigned to one group that did not undergo surgical intervention and another that underwent RPVC using denacol-treated canine aortic valved grafts (PAB+RPVC). Twelve weeks later, the rate of change in the RV-PA systolic pressure gradient was significantly decreased in the PAB+RPVC, compared with the PAB group (60.5 +/- 16.7% vs. 108.9 +/- 22.9%; p<0.01). In addition, the end-diastolic RV free wall thickness (RVFWd) was significantly reduced in the PAB+RPVC, compared with the PAB group (8.2 +/- 0.2 vs. 9.4 +/- 0.7 mm; p<0.05). Thereafter, regurgitation was not evident beyond the conduit valve and the decrease in RV pressure overload induced by RPVC was confirmed. The present results indicate that RPVC can be performed under a beating heart without cardiopulmonary bypass and adapted to dogs with various types of PS, including "supra valvular" PS or PS accompanied by dysplasia of the pulmonary valve. Therefore, we consider that this method is useful for treating PS in small animals.

  19. Contegra valved conduit in the paediatric population: an exciting prospect for right ventricle to pulmonary artery reconstruction; experience and outcomes at Aga Khan University.

    PubMed

    Siddiqui, Maria Tariq; Hasan, Asif; Mohsin, Shazia; Hamid, Mohammad; Amanullah, Muhammad Muneer

    2012-10-01

    The focus of this study is to share the experience and outcomes of Contegra graft implantation in the paediatric and adult population in Pakistan. Between May 2007 and July 2011, 16 patients, underwent implantation of a Contegra valved conduit. All operations were performed through a median sternotomy with cardiopulmonary bypass. Indications included: Pulmonary atresia with ventricular septal defect (n = 11), Tetralogy of Fallot with absent Pulmonary Valve (PV) syndrome (n = 2), double outlet right ventricle, transposition of great arteries and pulmonary stenosis (n = 1), isolated aortic valve disease (n = 1) and a pseudo-aneurysm with infective endocarditis (n = 1).Conduit sizes varied between 16-22 mm. The three in hospital deaths were unrelated to the Contegra valved conduit. One patient was lost to follow up. Of the 12 survivors, 10 are currently free from re-operation or complications related to the conduit while one needed distal pulmonary artery dilatation owing to critical stenosis and another had severe Valvular regurgitation. Echocardiographic evaluation of the Contegra valved conduit demonstrated no haemodynamically significant valve regurgitation in 10 patients. In this small review of 16 operations using the Contegra valved conduit for Right Venticular Outflow Tract (RVOT) reconstruction in the paediatric population, we observed good post operative results concerning conduit function. The Contegra conduit provides an excellent substitute to the homograft with satisfactory early and mid-term results though long-term results are awaited in Pakistan.

  20. Early graft failure of small-sized porcine valved conduits in reconstruction of the right ventricular outflow tract.

    PubMed

    Schreiber, Christian; Sassen, Stefanie; Kostolny, Martin; Hörer, Jürgen; Cleuziou, Julie; Wottke, Michael; Holper, Klaus; Fend, Falko; Eicken, Andreas; Lange, Rüdiger

    2006-07-01

    The quest for an alternative to homografts for reconstruction of the right ventricular outflow tract is ongoing. The Shelhigh No-React (NR-4000PA series) treated porcine pulmonic valve conduit (SPVC) was developed as a potential alternative. During a 12-month period from May 2004 to May 2005, the SPVC was implanted in 34 patients, of whom 62% were younger than 1 year. Median age at operation was 7 months (range, 5 days to 12 years). Thirteen SPCV conduits size 10, 11 size 12, 8 size 14, and 2 size 16 were initially implanted. Since May 2005, however, we have temporarily abandoned its implantation as we were concerned about a number of early failures. Until November 2005, 1 early and 1 late death have occurred. Both were not conduit related. Fifteen conduits were replaced in 13 patients. Of these, 10 were size 10, 3 size 12, 2 size 14, and none size 16. Mean time to replacement of the SPVC was 313 +/- 116 days. A pseudointimal peel formation and chronic inflammation with foreign-body reaction was found in all explanted conduits at all levels. The maximum of the inflammatory reaction occurred at the valvular level around the porcine tissues, with shrinkage of the valve and hemodynamic compromise. At valvular level, small punctuate calcifications were observed in 2 cases. In 6 patients an acute inflammatory component was observed. At late follow-up (mean follow-up 366 +/- 102 days, 34 patient-years), echocardiography showed a mean graft gradient of 39.8 +/- 29.7 mm Hg, with mild to moderate insufficiency in 4 patients. Although the No-React treated valve largely resists calcification, pseudointimal peel formation was found in all explanted conduits and led to multilevel conduit stenoses. The small-sized SPVC can not be regarded as an ideal conduit for right ventricular outflow tract reconstruction.

  1. Left ventricle to aorta valved conduit for relief of diffuse left ventricular outflow tract obstruction.

    PubMed

    Reder, R F; Dimich, I; Steinfeld, L; Litwak, R S

    1977-06-01

    Operative relief of congenital tunnel subaortic stenosis by means of local incision or excision, or both, has generally been unsatisfactory. The use of a valve-bearing conduit between the left ventricular apex and thoracic aorta offers a predictable means of bypassing the left ventricular outflow obstruction. The procedure was used in a 17 year old girl with an excellent hemodynamic result. The history of operative management with diverting plantation of valved conduits in this position have not been defined, but use of these prostheses appears advisable in severe subvalvular, valvular and supravalvular obstructions that are not readily amenable to predictable and safe surgical palliation. The operation may prove useful in selected cases of idiopathic hypertrophic obstructive cardiomyopathy.

  2. The Contegra bovine valved jugular vein conduit for pediatric RVOT reconstruction: 4 years experience with 108 patients.

    PubMed

    Breymann, Thomas; Boethig, Dietmar; Goerg, Reiner; Thies, Wolf-Rüdiger

    2004-01-01

    Porcine xenografts for pediatric right ventricular outflow tractus (RVOT) reconstruction lack durability, homografts lack availability. The Contegra is a valve bearing bovine jugular vein. It is tear resistant, well pliable, and permits RVOT reconstruction without further foreign material. The 108 Contegras implanted in Bad Oeynhausen from May 1999 until January 2003 represent the largest single-center Contegra experience. The study gives the preliminary results from a controlled prospective multicenter trial aiming at FDA admission. The patients' diagnoses were truncus arteriosus (27%), double outlet right ventricle (14%), tetralogy of Fallot (48%), transposition of great arteries (6%), rare complex malformation (2%), and Ross procedure (1%). Fifty-eight were female. Age: 2 days to 20.1 years, mean: 4.3 +/- 5.2, median: 1.8 years. Thirty-three had primary implantations, 38 previous repairs, 37 conduit exchange. Total follow-up time: 227.7 years, mean: 2.1. About 848 echos were evaluated. Early mortality: 7.4% (8 patients); 1 late death. None was Contegra-related. Echocardiographic controls showed no relevant average valvular gradient development. Trace and mild-grade insufficiency is frequent, without tendency to increase. Average insufficiency is between trace and mild unless RV pressure remains under 100 mmHg. Average individual right/left ventricle length ratios did not increase over time. We saw no relevant conduit dilatation and no leaflet calcification. Pulmonary artery stenoses had mainly extrinsic reasons. At 4 years, freedom- from- event rates were: reoperation for Conduit inflow or valvular degeneration: 100%; reoperation for pulmonary artery branch stenoses (n = 10) 86%, explantation (n = 4): 92%. Survival: 91.7%. Contegra is worth being considered as an alternative to homografts.

  3. Failing left ventricle to ascending aorta conduit-Hybrid implantation of a melody valve and NuMed covered stent.

    PubMed

    Gössl, Mario; Johnson, Jonathan N; Hagler, Donald J

    2014-04-01

    We present the case of a 36-year-old woman with increasing shortness of breath, a new 3/4 diastolic murmur, and a complex history of LV outflow tract obstruction. She has undergone multiple surgeries including the replacement of her old LV apex to ascending aorta conduit with a 20-mm Gore-Tex tube graft, addition of a 24-mm homograft sutured between the conduit and the LV apex, and insertion of a 21-mm Freestyle porcine valve conduit between the Gore-Tex tube graft and allograft at age 23. The current assessment showed a failing Freestyle conduit prosthesis leading to left heart decompensation. Due to substantial surgical risk, the patient underwent successful implantation of a Melody valve into the Gore-Tex tube and exclusion of the failing Freestyle bioprosthesis with a NuMed CP stent in a hybrid procedure. The case nicely illustrates the collaborative potential of cardiovascular surgeons and interventional cardiologists in the new arena of a hybrid operating room. Complex hybrid procedures like the current one, especially those including percutaneous placements of valves, offer therapeutic options for patients that are otherwise too high risk for conventional open heart surgery. Copyright © 2013 Wiley Periodicals, Inc.

  4. Left ventricle descending aorta valved conduit to relieve congenital aortic stenosis in children.

    PubMed

    Eijgelaar, A; Hess, J; Cromme-Dijkhuis, A H; Karliczek, G F; Homan van der Heide, J N

    1984-10-01

    A valved conduit was inserted between the apex of the left ventricle and the descending aorta in 2 patients, 4 months and 10 years of age, respectively, who had valvular aortic stenosis. The development of both patients has been excellent since operation. At control catheterization (1 and 2 years postoperatively) no pressure gradient was found between the left ventricle and the aorta. In both patients the aortic valve area showed growth to near normal size on echocardiographic study 3 years postoperatively.

  5. Development of a completely autologous valved conduit with the sinus of Valsalva using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model.

    PubMed

    Yamanami, Masashi; Yahata, Yuki; Uechi, Masami; Fujiwara, Megumi; Ishibashi-Ueda, Hatsue; Kanda, Keiichi; Watanabe, Taiji; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2010-09-14

    We developed autologous prosthetic implants by simple and safe in-body tissue architecture technology. We present the first report on the development of autologous valved conduit with the sinus of Valsalva (BIOVALVE) by using this unique technology and its subsequent implantation in the pulmonary valves in a beagle model. A mold of BIOVALVE organization was assembled using 2 types of specially designed silicone rods with a small aperture in a trileaflet shape between them. The concave rods had 3 projections that resembled the protrusions of the sinus of Valsalva. The molds were placed in the dorsal subcutaneous spaces of beagle dogs for 4 weeks. The molds were covered with autologous connective tissues. BIOVALVEs with 3 leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds. These valves had adequate burst strength, similar to that of native valves. Tight valvular coaptation and sufficient open orifice area were observed in vitro. These BIOVALVEs were implanted to the main pulmonary arteries as allogenic conduit valves (n=3). Postoperative echocardiography demonstrated smooth movement of the leaflets with trivial regurgitation. Histological examination of specimens obtained at 84 days showed that the surface of the leaflet was covered by endothelial cells and neointima, including an elastin fiber network, and was formed at the anastomosis sides on the luminal surface of the conduit. We developed the first completely autologous BIOVALVE and successfully implanted these BIOVALVEs in a beagle model in a pilot study.

  6. Multiple-port valve

    DOEpatents

    Doody, Thomas J.

    1978-08-22

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable wih one or more of a plurality of secondary conduits fitted into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits.

  7. Jugular venous valved conduit (Contegra) matches allograft performance in infant truncus arteriosus repair.

    PubMed

    Hickey, Edward J; McCrindle, Brian W; Blackstone, Eugene H; Yeh, Thomas; Pigula, Frank; Clarke, David; Tchervenkov, Christo I; Hawkins, John

    2008-05-01

    Limited availability and durability of allograft conduits require that alternatives be considered. We compared bovine jugular venous valved (JVV) and allograft conduit performance in 107 infants who survived truncus arteriosus repair. Children were prospectively recruited between 2003 and 2007 from 17 institutions. The median z-score for JVV (n=27, all 12 mm) was +2.1 (range +1.2 to +3.2) and allograft (n=80, 9-15mm) was +1.7 (range -0.4 to +3.6). Propensity-adjusted comparison of conduit survival was undertaken using parametric risk-hazard analysis and competing risks techniques. All available echocardiograms (n=745) were used to model deterioration of conduit function in regression equations adjusted for repeated measures. Overall conduit survival was 64+/-9% at 3 years. Conduit replacement was for conduit stenosis (n=16) and/or pulmonary artery stenosis (n=18) or regurgitation (n=1). The propensity-adjusted 3-year freedom from replacement for in-conduit stenosis was 96+/-4% for JVV and 69+/-8% for allograft (p=0.05). The risk of intervention or replacement for branch pulmonary artery stenosis was similar for JVV and allograft. Smaller conduit z-score predicted poor conduit performance (p<0.01) with best outcome between +1 and +3. Although JVV conduits were a uniform diameter, their z-score more consistently matched this ideal. JVV exhibited a non-significant trend towards slower progression of conduit regurgitation and peak right ventricular outflow tract (RVOT) gradient. In addition, catheter intervention was more successful at slowing subsequent gradient progression in children with JVV versus those with allograft (p<0.01). JVV does match allograft performance and may be advantageous. It is an appropriate first choice for repair of truncus arteriosus, and perhaps other small infants requiring RVOT reconstruction.

  8. Effect of three decellularisation protocols on the mechanical behaviour and structural properties of sheep aortic valve conduits.

    PubMed

    Khorramirouz, Reza; Sabetkish, Shabnam; Akbarzadeh, Aram; Muhammadnejad, Ahad; Heidari, Reza; Kajbafzadeh, Abdol-Mohammad

    2014-09-01

    To determine the best method for decellularisation of aortic valve conduits (AVCs) that efficiently removes the cells while preserving the extracellular matrix (ECM) by examining the valvular and conduit sections separately. Sheep AVCs were decellularised by using three different protocols: detergent-based (1% SDS+1% SDC), detergent and enzyme-based (Triton+EDTA+RNase and DNase), and enzyme-based (Trypsin+RNase and DNase) methods. The efficacy of the decellularisation methods to completely remove the cells while preserving the ECM was evaluated by histological evaluation, scanning electron microscopy (SEM), hydroxyproline analysis, tensile test, and DAPI staining. The detergent-based method completely removed the cells and left the ECM and collagen content in the valve and conduit sections relatively well preserved. The detergent and enzyme-based protocol did not completely remove the cells, but left the collagen content in both sections well preserved. ECM deterioration was observed in the aortic valves (AVs), but the ultrastructure of the conduits was well preserved, with no media distortion. The enzyme-based protocol removed the cells relatively well; however, mild structural distortion and poor collagen content was observed in the AVs. Incomplete cell removal (better than that observed with the detergent and enzyme-based protocol), poor collagen preservation, and mild structural distortion were observed in conduits treated with the enzyme-based method. The results suggested that the detergent-based methods are the most effective protocols for cell removal and ECM preservation of AVCs. The AVCs treated with this detergent-based method may be excellent scaffolds for recellularisation. Copyright © 2014 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  9. Delayed Infective Endocarditis with Mycotic Aneurysm Rupture below the Mechanical Valved Conduit after the Bentall Procedure

    PubMed Central

    Chen, Mei-Ling; Chen, Michael Y.; Yin, Wei-Hsian; Wei, Jeng; Wang, Ji-Hung

    2014-01-01

    The Bentall procedure is the gold standard for treating aortic dissection complicated with valvular and ascending aorta disease. Recent results for this procedure have been excellent; nearly 100% of patients remain free of infective endocarditis in long-term follow-up. We report a case of delayed Streptococcus agalactiae infective endocarditis complicated by mycotic aneurysm in a man who had undergone the Bentall procedure with a mechanical valve conduit 15 years previously. The mycotic aneurysm was located in the remnant aortic root, below the mechanical valve conduit, and later ruptured into the right atrium. The patient was treated conservatively and survived the acute period. Later, the aortic root defect was repaired successfully by means of a hybrid technique using a Amplatzer duct occluder. PMID:27122809

  10. Percutaneous pulmonary valve implantation for free pulmonary regurgitation following conduit-free surgery of the right ventricular outflow tract.

    PubMed

    Cools, Bjorn; Brown, Stephen C; Heying, Ruth; Jansen, Katrijn; Boshoff, Derize E; Budts, Werner; Gewillig, Marc

    2015-01-01

    Pulmonary regurgitation (PR) following surgery of the right ventricular outflow tract (RVOT) is not innocent and leads to significant right heart dysfunction over time. Recent studies have demonstrated that percutaneous valves can be implanted in conduit free outflow tracts with good outcomes. To evaluate in patients with severe PR--anticipated to require future pulmonary valve replacement--the feasibility and safety of pre-stenting dilated non-stenotic patched conduit-free right ventricular outflow tracts before excessive dilation occurs, followed by percutaneous pulmonary valve implantation (PPVI). Twenty seven patients were evaluated, but only 23 were deemed suitable based on the presence of an adequate retention zone ≤ 24 mm defined by semi-compliant balloon interrogation of the RVOT. A 2 step procedure was performed: first the landing zone was prepared by deploying a bare stent, followed 2 months later by valve implantation. RVOT pre-stenting with an open cell bare metal stent (Andrastent XXL range) was performed at a median age of 13.0 years (range: 6.0-44.9) with a median weight of 44.3 kg (range: 20.0-88.0). Ninety six percent (22/23) of patients proceeded to PPVI a median of 2.4 months (range: 1.4-3.4) after initial pre-stent placement. Twenty one Melody valves and one 26 mm Edwards SAPIEN™ valve were implanted. Complications consisted of embolization of prestent (n = 1), scrunching (n = 4) and mild stent dislocation (n = 2). During follow-up, no stent fractures were observed and right ventricular dimensions decreased significantly. Post-surgical conduit-free non-stenotic RVOT with free pulmonary regurgitation can be treated percutaneously with a valved stent if anatomical (predominantly size) criteria are met. In experienced hands, the technique is feasible with low morbidity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Long-term results after aortic valve replacement with the Biocor PSB stentless xenograft in the elderly.

    PubMed

    Luciani, G B; Santini, F; Auriemma, S; Barozzi, L; Bertolini, P; Mazzucco, A

    2001-05-01

    This study seeks to define the long-term results after Biocor PSB stentless aortic valve replacement (AVR) in elderly patients, including the effects of No-React treatment. We reviewed the outcomes of 106 consecutive patients, aged 70+/-6 years, having Biocor PSB (93 standard, 13 No-React) AVR between October 1992 and October 1996. There were three early deaths (3%) and 15 late deaths (15%), during a mean follow-up of 5.8+/-1.6 years. At 8 years, survival was 82%+/-4% and freedom from cardiac death was 94%+/-3%. Freedom from valve failure was 92%+/-4% at 8 years (No-React: 92%+/-8% at 4 years). Replacement of the xenograft was required in 5 patients. Freedom from reoperation was 91%+/-4% at 8 years (No-React: 92%+/-8% at 4 years). Four bleeding and two embolic events were recorded: overall valve-related event-free survival was 81%+/-7% at 8 years (No-React: 76%+/-12% at 4 years). Age of long-term survivors averaged 77+/-5 years and their New York Heart Association status was 1.3+/-0.6 (versus 2.9+/-0.6 preoperatively, p = 0.01). Satisfactory freedom from cardiac events and from valve deterioration added to uniform improvement in functional status despite advanced age and high prevalence of comorbid conditions make AVR with the Biocor PSB xenograft a valid long-term therapy for the elderly. No-React treatment does not influence xenograft durability.

  12. Delayed Infective Endocarditis with Mycotic Aneurysm Rupture below the Mechanical Valved Conduit after the Bentall Procedure.

    PubMed

    Chen, Mei-Ling; Chen, Michael Y; Yin, Wei-Hsian; Wei, Jeng; Wang, Ji-Hung

    2014-07-01

    The Bentall procedure is the gold standard for treating aortic dissection complicated with valvular and ascending aorta disease. Recent results for this procedure have been excellent; nearly 100% of patients remain free of infective endocarditis in long-term follow-up. We report a case of delayed Streptococcus agalactiae infective endocarditis complicated by mycotic aneurysm in a man who had undergone the Bentall procedure with a mechanical valve conduit 15 years previously. The mycotic aneurysm was located in the remnant aortic root, below the mechanical valve conduit, and later ruptured into the right atrium. The patient was treated conservatively and survived the acute period. Later, the aortic root defect was repaired successfully by means of a hybrid technique using a Amplatzer duct occluder. Amplatzer duct occluder; Aortic dissection; Bentall technique; Infective endocarditis; Mycotic aneurysm.

  13. In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model.

    PubMed

    Takewa, Yoshiaki; Yamanami, Masashi; Kishimoto, Yuichiro; Arakawa, Mamoru; Kanda, Keiichi; Matsui, Yuichi; Oie, Tomonori; Ishibashi-Ueda, Hatsue; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Nakayama, Yasuhide

    2013-06-01

    Using simple, safe, and economical in-body tissue engineering, autologous valved conduits (biovalves) with the sinus of Valsalva and without any artificial support materials were developed in animal recipients' bodies. In this study, the feasibility of the biovalve as an aortic valve was evaluated in a goat model. Biovalves were prepared by 2-month embedding of the molds, assembled using two types of specially designed plastic rods, in the dorsal subcutaneous spaces of goats. One rod had three projections, resembling the protrusions of the sinus of Valsalva. Completely autologous connective tissue biovalves (type VI) with three leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds from both terminals of the harvested implants with complete encapsulation. The biovalve leaflets had appropriate strength and elastic characteristics similar to those of native aortic valves; thus, a robust conduit was formed. Tight valvular coaptation and a sufficient open orifice area were observed in vitro. Biovalves (n = 3) were implanted in the specially designed apico-aortic bypass for 2 months as a pilot study. Postoperative echocardiography showed smooth movement of the leaflets with little regurgitation under systemic circulation (2.6 ± 1.1 l/min). α-SMA-positive cells appeared significantly with rich angiogenesis in the conduit and expanded toward the leaflet tip. At the sinus portions, marked elastic fibers were formed. The luminal surface was covered with thin pseudointima without thrombus formation. Completely autologous biovalves with robust and elastic characteristics satisfied the higher requirements of the systemic circulation in goats for 2 months with the potential for valvular tissue regeneration.

  14. An unusual cause of hemolysis in a patient with an aortic valved conduit replacement.

    PubMed

    Allman, Christine; Rajaratnam, Rohan; Kachwalla, Hashim; Hughes, Clifford F; Bannon, Paul; Leung, Dominic Y

    2003-02-01

    Hemolytic anemia is a well-known but uncommon complication in patients with prosthetic heart valves. It is most commonly a result of prosthetic valve dysfunction, periprosthetic valvular regurgitation, or both. We report a case of a 41-year-old man who had a previous aortic valve and root replacement for acute proximal aortic dissection, now presenting with hemolytic anemia. This was a result of flow obstruction at the distal anastomosis of the aortic conduit by the presence of multiple dissection flaps resulting in severe flow turbulence. Although the pathology was at the blind spot for transesophageal echocardiography, the dissection flaps, the flow turbulence, and the degree of obstruction were well-demonstrated by this technique after careful manipulation of the probe and a high index of suspicion.

  15. Expandable right ventricular-to-pulmonary artery conduit: an animal study.

    PubMed

    Boudjemline, Younes; Laborde, François; Pineau, Emmanuelle; Mollet, Alix; Abadir, Sylvia; Borenstein, Nicolas; Behr, Luc; Bonhoeffer, Philipp

    2006-06-01

    This study was performed to assess a new vascular stent graft as an expandable valved conduit for right ventricular outflow tract (RVOT) reconstruction in sheep. Conduits were constructed by sewing an 18-mm valved conduit inside a stent. Crimped to 16 mm, they were implanted either under or without extracorporeal circulation in seven (group A) and in five (group B) sheep, respectively. Six weeks and 3 mo after their insertion, conduits were dilated intraluminally. A valved stent was implanted percutaneously into conduits before they were killed. Two animals from group A recovered normally, whereas five animals had a complicated postoperative course. In group B, one died acutely due to kinking of the conduit. Balloon dilatations were performed in all surviving animals. First dilatations had a slight impact on valvular function in all animals but one, whereas second dilatations led to significant PR in all. Transcatheter valve implantation was performed successfully. When animals were killed, no bleeding was found around the surgically implanted device. In conclusion, we designed a biologic valved conduit for RVOT reconstruction that can be dilated sequentially to follow animal growth. This new device can have tremendous applications in children with congenital heart diseases involving the RVOT.

  16. Control Valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Wayne R.

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between amore » first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.« less

  17. Intermediate follow-up of a composite stentless porcine valved conduit of bovine pericardium in the pulmonary circulation.

    PubMed

    Aupècle, Bertrand; Serraf, Alain; Belli, Emre; Mohammadi, Siamak; Lacour-Gayet, François; Fornes, Paul; Planché, Claude

    2002-07-01

    In the pediatric population, glutaraldehyde-preserved bovine pericardium conduit containing a stentless porcine valve has been proposed as an alternative to homografts for right ventricular outflow tract reconstruction. Between June 1996 and March 2000, a total of 55 patients, 20 with truncus arteriosus, 21 with pulmonary atresia with ventricular septal defect, and 14 with miscellaneous defects, received this conduit. Median age at implantation was 3.4 months (range, 3 days to 19 years), and 27 patients (50%) were less than 3 months old. Clinical outcome, echocardiographic data, and pathologic analysis were recorded. End points for conduit failure were conduit replacement or dilation. A mean follow-up of 27 months (range, 2 to 46 months) was available for 47 survivors. Procedure for conduit obstruction was required in 13 patients. The most common procedure was operation, and all but 3 patients had an unsuccessful balloon angioplasty before reoperation. Actuarial freedom from conduit dilation or reoperation was 93.6% (95% confidence limits, 82% to 99%), 81.9% (95% confidence limits, 64% to 91%), 77.8% (95% confidence limits, 39% to 78%), and 64.3% (95% confidence limits, 26% to 73%) at 1, 2, 3, and 4 postoperative years, respectively. Univariate analysis identified small conduit size as a risk factor for conduit obstruction. Although this new conduit was not free from progressive obstruction, our clinical results (easy to work and good valvular function) and the availability in small sizes encouraged us to use it as an alternative to small-size homografts when those were not available.

  18. Surgical treatment of left ventricular outflow tract obstruction with apicoaortic valved conduit.

    PubMed

    Cooley, D A; Norman, J C; Reul, G J; Kidd, J N; Nihill, M R

    1976-12-01

    From Aug. 13, 1975, through May, 1976, nine patients underwent creation of a left ventricular "vent" for relief of severe left ventricular outflow tract obstruction. A Dacron fabric graft containing a heterograft valve was used to establish a conduit from the left ventricle to the abdominal aorta. There were five male and four female patients in this group; their ages ranged from 4 to 72 years. All had valvular, subvalvular, or supravalvular aortic stenosis, and all but two had undergone previous surgical procedures for relief of the stenosis. All patients survived the operation and none are receiving anticoagulant therapy. All are asymptomatic at present and follow-up is approaching one year. Postoperative cardiac catheterization studies revealed gradients across the aortic valve to be reduced by approximately 90% and mean ventricular systolic pressures by 45%. Although this concept is not new, it has not been used widely and we believe its effectiveness warrants further application.

  19. Decellularization of human donor aortic and pulmonary valved conduits using low concentration sodium dodecyl sulfate

    PubMed Central

    Vafaee, Tayyebeh; Thomas, Daniel; Desai, Amisha; Jennings, Louise M.; Berry, Helen; Rooney, Paul; Kearney, John; Fisher, John

    2017-01-01

    Abstract The clinical use of decellularized cardiac valve allografts is increasing. Long‐term data will be required to determine whether they outperform conventional cryopreserved allografts. Valves decellularized using different processes may show varied long‐term outcomes. It is therefore important to understand the effects of specific decellularization technologies on the characteristics of donor heart valves. Human cryopreserved aortic and pulmonary valved conduits were decellularized using hypotonic buffer, 0.1% (w/v) sodium dodecyl sulfate and nuclease digestion. The decellularized tissues were compared to cellular cryopreserved valve tissues using histology, immunohistochemistry, quantitation of total deoxyribose nucleic acid, collagen and glycosaminoglycan content, in vitro cytotoxicity assays, uniaxial tensile testing and subcutaneous implantation in mice. The decellularized tissues showed no histological evidence of cells or cell remnants and >97% deoxyribose nucleic acid removal in all regions (arterial wall, muscle, leaflet and junction). The decellularized tissues retained collagen IV and von Willebrand factor staining with some loss of fibronectin, laminin and chondroitin sulfate staining. There was an absence of major histocompatibility complex Class I staining in decellularized pulmonary valve tissues, with only residual staining in isolated areas of decellularized aortic valve tissues. The collagen content of the tissues was not decreased following decellularization however the glycosaminoglycan content was reduced. Only moderate changes in the maximum load to failure of the tissues were recorded postdecellularization. The decellularized tissues were noncytotoxic in vitro, and were biocompatible in vivo in a mouse subcutaneous implant model. The decellularization process will now be translated into a good manufacturing practices‐compatible process for donor cryopreserved valves with a view to future clinical use. Copyright © 2016 The Authors

  20. Histological study of right ventricle-pulmonary artery valved conduit implantation (RPVC) in dogs with pulmonic stenosis.

    PubMed

    Saida, Yuuto; Tanaka, Ryou; Fukushima, Ryuji; Hira, Satoshi; Hoshi, Katsuichiro; Soda, Aiko; Iizuka, Tomoya; Ishikawa, Taisuke; Nishimura, Taiki; Yamane, Yoshihisa

    2009-04-01

    We examined whether right ventricle-pulmonary artery valved conduit (RPVC) implantation can overcome the disadvantages of current procedures for pulmonic stenosis (PS). We histologically evaluated the feasibility of RPVC using a homograft in PS model dogs. Eight dogs underwent pulmonary artery banding (PAB) and then 12 weeks later were assigned to PAB (n=4) or PAB+RPVC (n=4) groups. Dogs in the PAB group received no treatment throughout the experimental period, whereas the PAB+RPVC group underwent RPVC. At 1 year after PAB, hearts and conduits were explanted from euthanized dogs and histologically evaluated. The ratios (%) of myocardial fibrosis on right ventricle (RV) epicardial, median and endocardial layers were significantly lower in the PAB+RPVC, than in the PAB group. The ratio of myocardial fibrosis on left ventricular (LV) epicardial and endocardial layers were significantly lower in the PAB+RPVC, than in the PAB group. Neo-intimal thickness in the anastomosis areas of the Denacol and PAB+RPVC groups was 42.77 +/- 30.19 and 88.30 +/- 27.24 microm, respectively, with no significant differences between the groups. Calcification and neo- intima hypertrophy were not obvious in the valve area. Immunohistological staining showed that the internal surface of the anastomosis and intermediate areas were positive for endothelial cells. We concluded that RPVC using a bioprosthetic graft can apparently overcome the disadvantages of current procedures for pulmonic stenosis.

  1. Ross operation using a bovine bioprosthetic valve with autologous pericardial conduit in the pulmonary position.

    PubMed Central

    Urrea, M S; Herrera, V; Rey, A; Vargas, J

    1993-01-01

    Between 1 February 1992 and 1 March 1993, we performed Ross's aortic replacement in 7 men and 4 women with rheumatic heart disease. The patients' ages ranged from 22 to 60 years (mean, 41 years). All 11 patients had aortic valve disease; 2 also had mitral valve disease. In all patients, the right ventricular outflow tract was reconstructed using an autologous pericardial conduit containing a bovine cardiac valve bioprosthesis manufactured at our institution. The 2 patients who had mitral valve disease underwent a concomitant mitral valvuloplasty. In 1 patient, minimal aortic regurgitation was documented by means of transesophageal echocardiography immediately after the cessation of cardiopulmonary bypass, but no hemodynamic compromise was noted. In another patient, mediastinal exploration was required for bleeding, 3.5 hours postoperatively. The follow-up period ranged from 6 to 16 months (mean, 11.3 months). Results were assessed by means of clinical and transesophageal echocardiographic studies. No infection or technical failure was encountered. No patient died. All patients remain asymptomatic, and follow-up echocardiography has revealed no transaortic or transpulmonary gradient. The Ross operation was chosen for this group of patients because it avoids the use of mechanical valves and subsequent anticoagulant therapy. Most of our patients have a low income and a history of noncompliance with the strict postoperative drug regimen. Although the short-term results have been excellent with the Ross operation and our combination bioprosthesis, long-term evaluation is needed. PMID:8298323

  2. Peripheral nerve conduits: technology update

    PubMed Central

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  3. Fast acting multiple element valve

    DOEpatents

    Yang, Jefferson Y. S.; Wada, James M.

    1991-01-01

    A plurality of slide valve elements having plural axial-spaced annular parts and an internal slide are inserted into a bulkhead in a fluid conduit from a downstream side of the bulkhead, locked in place by a bayonet coupling and set screw, and project through the bulkhead into the upstream conduit. Pneumatic lines connecting the slide valve element actuator to pilot valves are brought out the throat of the valve element to the downstream side. Pilot valves are radially spaced around the exterior of the valve to permit the pneumatic lines to be made identical, thereby to minimize adverse timing tolerances in operation due to pressure variations. Ring manifolds surround the valve adjacent respective pilot valve arrangements to further reduce adverse timing tolerances due to pressure variations, the manifolds being directly connected to the respective pilot valves. Position sensors are provided the valve element slides to signal the precise time at which a slide reaches or passes through a particular point in its stroke to initiate a calibrated timing function.

  4. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    PubMed

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p < 0.0001) during a median follow-up period of 24.0 and 35.5 months, respectively (p = 0.03). For patients with BJV valves, the incidence of IE was not different between surgical and catheter-based valve implantation (p = 0.83). There was a higher incidence of endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN XT transcatheter heart valve system.

    PubMed

    Haas, Nikolaus A; Carere, Ronald Giacomo; Kretschmar, Oliver; Horlick, Eric; Rodés-Cabau, Josep; de Wolf, Daniël; Gewillig, Marc; Mullen, Michael; Lehner, Anja; Deutsch, Cornelia; Bramlage, Peter; Ewert, Peter

    2018-01-01

    Patients with congenital or acquired heart defects affecting the pulmonary valve and right ventricular outflow tract (RVOT) commonly require multiple surgical interventions, resulting in significant morbidity. A less invasive alternative is percutaneous pulmonary valve implantation (PPVI). Though studies have previously reported the safety and efficacy of the early generation transcatheter heart valves (THVs), data on more recent devices are severely lacking. We performed a multinational, multicentre, retrospective, observational registry analysis of patients who underwent PPVI using the Edwards SAPIEN XT THV. Of the 46 patients that were enrolled, the majority had tetralogy of Fallot as the underlying diagnosis (58.7%), and stentless xenograft as the most common RVOT anatomy (34.8%). Procedural success rate was high (93.5%), with a low frequency of periprocedural complications and adverse events (6.5% and 10.9%, respectively). At 30days post-procedure, NYHA class had improved significantly (90.6% were at NYHA I or II). The rate of moderate/severe pulmonary regurgitation had decreased from 76.1% at baseline to 5.0% at 30days, and the calculated peak systolic gradient had decreased from 45.2 (SD±21.3) mmHg to 16.4 (SD±8.0) mmHg, with these values remaining low up to 2years. The data suggest the efficacy and safety of the SAPIEN XT THV in PPVI in common anatomies in patients with conduits, as well as those with native pulmonary valves or transannular patches. Continued data collection is necessary to verify long-term findings. CLINICALTRIALS. NCT02302131. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Apical Aortic Conduit Infection 27 Years After Repaired Left Ventricular Outflow Tract Obstruction.

    PubMed

    Carpenter, Dustin J; Fiore, Andrew C; Huddleston, Charles B

    2014-07-01

    Left ventricle to aortic conduits were used for the treatment of complex left ventricular outflow tract obstruction in the pediatric population in the mid-1970s. Although this technique has been largely replaced by the Ross-Konno procedure, many patients still have functioning apicoaortic conduits in place today. Few clinical reports or case series exist in pediatric cohorts documenting the natural history or potential long-term complications of this prosthesis. In this report, we describe our experience managing a patient with Shone's syndrome and an apical aortic porcine-valved conduit remnant that became infected 17 years postconduit valve excision for valvular insufficiency. © The Author(s) 2014.

  7. [Method to make the tricuspid extracardiac conduit by heterogeneous pericardium].

    PubMed

    Yamagishi, M; Imai, Y; Koh, Y; Nagatsu, M; Matsuo, K; Kurosawa, H

    1992-07-01

    We described here, how to make tricuspid extracardiac conduit by heterogeneous pericardium for Rastelli procedure. We have developed some ingenious devices which allow to obtain good hemodynamics. One of the devices is large valvular leaflets as long as 130% of the circumference of the conduit. Another device is the commissural suture as figure of eight. We used 121 tricuspid extracardiac conduits between January 1985 and March 1991. There were two reoperations: One from stenosis at the suture with ventricle and the other from infective endocarditis. This hand-made conduit has the advantages of flexibility, fitness with the pulmonary artery, wide range of size and very little regurgitation. These advantages indicate that the tricuspid extracardiac conduit made by heterogeneous pericardium is a valved conduit substitute of choice for Rastelli procedure. The durability of the conduit is to be further evaluated.

  8. Virtual Surgery for Conduit Reconstruction of the Right Ventricular Outflow Tract.

    PubMed

    Ong, Chin Siang; Loke, Yue-Hin; Opfermann, Justin; Olivieri, Laura; Vricella, Luca; Krieger, Axel; Hibino, Narutoshi

    2017-05-01

    Virtual surgery involves the planning and simulation of surgical reconstruction using three-dimensional (3D) modeling based upon individual patient data, augmented by simulation of planned surgical alterations including implantation of devices or grafts. Here we describe a case in which virtual cardiac surgery aided us in determining the optimal conduit size to use for the reconstruction of the right ventricular outflow tract. The patient is a young adolescent male with a history of tetralogy of Fallot with pulmonary atresia, requiring right ventricle-to-pulmonary artery (RV-PA) conduit replacement. Utilizing preoperative magnetic resonance imaging data, virtual surgery was undertaken to construct his heart in 3D and to simulate the implantation of three different sizes of RV-PA conduit (18, 20, and 22 mm). Virtual cardiac surgery allowed us to predict the ability to implant a conduit of a size that would likely remain adequate in the face of continued somatic growth and also allow for the possibility of transcatheter pulmonary valve implantation at some time in the future. Subsequently, the patient underwent uneventful conduit change surgery with implantation of a 22-mm Hancock valved conduit. As predicted, the intrathoracic space was sufficient to accommodate the relatively large conduit size without geometric distortion or sternal compression. Virtual cardiac surgery gives surgeons the ability to simulate the implantation of prostheses of different sizes in relation to the dimensions of a specific patient's own heart and thoracic cavity in 3D prior to surgery. This can be very helpful in predicting optimal conduit size, determining appropriate timing of surgery, and patient education.

  9. The challenge of valve-in-valve procedures in degenerated Mitroflow bioprostheses and the advantage of using the JenaValve transcatheter heart valve.

    PubMed

    Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik

    2014-12-01

    Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.

  10. System and method for bidirectional flow and controlling fluid flow in a conduit

    DOEpatents

    Ortiz, Marcos German

    1999-01-01

    A system for measuring bidirectional flow, including backflow, of fluid in a conduit. The system utilizes a structural mechanism to create a pressure differential in the conduit. Pressure sensors are positioned upstream from the mechanism, at the mechanism, and downstream from the mechanism. Data from the pressure sensors are transmitted to a microprocessor or computer, and pressure differential detected between the pressure sensors is then used to calculate the backflow. Control signals may then be generated by the microprocessor or computer to shut off valves located in the conduit, upon the occurrence of backflow, or to control flow, total material dispersed, etc. in the conduit.

  11. System and method for bidirectional flow and controlling fluid flow in a conduit

    DOEpatents

    Ortiz, M.G.

    1999-03-23

    A system for measuring bidirectional flow, including backflow, of fluid in a conduit is disclosed. The system utilizes a structural mechanism to create a pressure differential in the conduit. Pressure sensors are positioned upstream from the mechanism, at the mechanism, and downstream from the mechanism. Data from the pressure sensors are transmitted to a microprocessor or computer, and pressure differential detected between the pressure sensors is then used to calculate the backflow. Control signals may then be generated by the microprocessor or computer to shut off valves located in the conduit, upon the occurrence of backflow, or to control flow, total material dispersed, etc. in the conduit. 3 figs.

  12. Pump having pistons and valves made of electroactive actuators

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph (Inventor)

    1997-01-01

    The present invention provides a pump for inducing a displacement of a fluid from a first medium to a second medium, including a conduit coupled to the first and second media, a transducing material piston defining a pump chamber in the conduit and being transversely displaceable for increasing a volume of the chamber to extract the fluid from the first medium to the chamber and for decreasing the chamber volume to force the fluid from the chamber to the second medium, a first transducing material valve mounted in the conduit between the piston and the first medium and being transversely displaceable from a closed position to an open position to admit the fluid to the chamber, and control means for changing a first field applied to the piston to displace the piston for changing the chamber volume and for changing a second field applied to the first valve to change the position of the first valve.

  13. Myectomy and LA-to-LV Conduit for Severe Calcific Mitral Stenosis and Hypertrophic Cardiomyopathy.

    PubMed

    Meghji, Zahara; Nguyen, Anita; Geske, Jeffrey B; Schaff, Hartzell V

    2018-02-26

    Severe calcific mitral valve stenosis can rarely occur concomitantly with obstructive hypertrophic cardiomyopathy. In these patients, surgical decalcification of the stenotic mitral valve followed by mitral valve replacement carries significant operative risk and may result in paravalvular leakage, atrioventricular groove disruption, and excessive bleeding. We report the first 2 cases of obstructive hypertrophic cardiomyopathy with severe calcific mitral valve stenosis successfully treated with concomitant transaortic septal myectomy and bypass of the stenotic mitral valve using a valved left atrium to left ventricular conduit. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Architecture of an in vivo-tissue engineered autologous conduit "Biovalve".

    PubMed

    Hayashida, Kyoko; Kanda, Keiichi; Oie, Tomonori; Okamoto, Yoshihiro; Ishibashi-Ueda, Hatsue; Onoyama, Masaaki; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2008-07-01

    As a practical concept of regenerative medicine, we have focused on in vivo tissue engineering utilizing the foreign body reaction. Plastic substrates for valvular leaflet organization, consisting of two pieces assembled with a small aperture were inserted into a microporous polyurethane conduit scaffold. The assembly was placed in the subcutaneous spaces of Japanese white rabbits for 1 month. After the substrates were pulled out from the harvested implant, valve leaflet-shaped membranous tissue was formed inside the tubular scaffold as designed. The valve leaflet was composed of the same collagen-rich tissue, with the absence of any elastic fiber, as that which had ingrown or covered the scaffold. No abnormal collection or infiltration of inflammatory cells in the leaflet and the scaffold could be demonstrated. According to the immunohistochemical staining, the leaflet was comprised of numerous vimentin- or alpha-SMA-positive cells, corresponding to fibroblasts or myofibroblats, but contained no desmin-positive cells. The analysis of the video data of the valve movement showed that, in synchronization with the backward flow in the diastolic phase, the valve closed rapidly and tightly and, in the transition phase of the flow direction, the valve opened smoothly without flapping or hitting the scaffold wall. Using mold designs, consisting of two different plastic substrates and the tubular scaffold, in conjunction with "in body tissue architecture," the complex 3-dimensional autologous conduit-typed Biovalve was developed for the first time. 2007 Wiley Periodicals, Inc.

  15. The search for valved conduit tissue grafts for adults (>22 mm): an ultrasonographic study of jugular vein diameters of horses and cattle

    PubMed Central

    Schwarzwald, Colin C; Jenni, Rolf

    2009-01-01

    Background Natural heterologous valved conduits with a diameter greater than 22 mm that can be used for right ventricular outflow tract reconstruction in adults are not commercially available. The purpose of this study was to measure by ultrasonography the maximum diameter of the distended jugular veins of horses and cattle, respectively, to identify a population of animals that would be suitable for post-mortem collection of jugular veins at sizes greater than 22 mm. Methods The study population included 60 Warmblood horses, 25 Freiberger horses, 20 Brown Swiss cows, and 20 Holstein cows (including 10 Holstein and 10 Red Holstein). The maximum cross-sectional diameter of the distended jugular veins was measured at a location half-way between the mandibular angle and the thoracic inlet. The thoracic circumference (heart girth length) was used as a surrogate of body size. The jugular vein diameters of the different populations were compared by analysis of variance and the association between heart girth length and jugular vein diameter was determined in each of the four study populations by linear regression analysis. Results There was considerable individual variation of jugular vein diameters within each of the four study populations. There was no statistically significant relationship between thoracic circumference and jugular vein diameter in any of the populations. The jugular vein diameters of Brown Swiss cows were significantly larger than those of any of the other populations. Warmblood horses had significantly larger jugular vein diameters compared to Freiberger horses. Conclusion The results of this study suggest that the production of bovine or equine xenografts with diameters of greater than 22 mm would be feasible. Differences between species and breeds need to be considered. However, prediction of the jugular vein diameter based on breed and heart girth length in an individual animal is inaccurate. PMID:19678940

  16. Endothelial Progenitor Cells as a Sole Source for Ex Vivo Seeding of Tissue-Engineered Heart Valves

    PubMed Central

    Mettler, Bret A.; Engelmayr, George C.; Aikawa, Elena; Bischoff, Joyce; Martin, David P.; Exarhopoulos, Alexis; Moses, Marsha A.; Schoen, Frederick J.; Sacks, Michael S.

    2010-01-01

    Purposes: We investigated whether circulating endothelial progenitor cells (EPCs) can be used as a cell source for the creation of a tissue-engineered heart valve (TEHV). Methods: Trileaflet valved conduits were fabricated using nonwoven polyglycolic acid/poly-4-hydroxybutyrate polymer. Ovine peripheral blood EPCs were dynamically seeded onto a valved conduit and incubated for 7, 14, and 21 days. Results: Before seeding, EPCs were shown to express CD31+, eNOS+, and VE-Cadherin+ but not α-smooth muscle actin. Histological analysis demonstrated relatively homogenous cellular ingrowth throughout the valved conduit. TEHV constructs revealed the presence of endothelial cell (EC) markers and α-smooth muscle actin+ cells comparable with native valves. Protein levels were comparable with native valves and exceeded those in unseeded controls. EPC-TEHV demonstrated a temporal pattern of matrix metalloproteinases-2/9 expression and tissue inhibitors of metalloproteinase activities comparable to that of native valves. Mechanical properties of EPC-TEHV demonstrated significantly greater stiffness than that of the unseeded scaffolds and native valves. Conclusions: Circulating EPC appears to have the potential to provide both interstitial and endothelial functions and could potentially serve as a single-cell source for construction of autologous heart valves. PMID:19698056

  17. [Simultaneous interventions on the ascending portion, arch of the aorta and cardiac valves in patients with Marfan's syndrome].

    PubMed

    Belov, Iu V; Stepanenko, A B; Gens, A P; Charchian, E R; Savichev, D D

    2007-01-01

    Simultaneous surgical interventions on the aorta and valvular system of the heart were performed in four patients presenting with aortic dissections and aneurysms conditioned by Marfan's syndrome. The following reconstructive operations were carried out: 1) prosthetic repair of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries into the side of the prosthesis according to the Benthall - De Bono technique, annuloplasty of the tricuspid valve according to the De Vega technique, valvuloplasty of the mitral valve by the Alferi technique; 2) grafting of the aortic valve and the ascending portion of the aorta by means of a valve-containing conduit with replantation of the openings of the coronary arteries according to the Kabrol's technique, plasty of the tricuspid valve by the De Vega technique; 3) prosthetic repair of the aortic arch with distal wedge-like excision of the membrane of the dissection and directing the blood flow along the both channels, plasty of the mitral valve, plasty of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side of the graft according to the Benthall - De Bono technique; (4) plasty of the mitral valve with a disk graft through the fibrous ring of the aortic valve, prosthetic repair of the aortic valve and the ascending portion of the aorta with a valve-containing conduit, accompanied by replantation of the openings of the coronary arteries into the side according to the Benthall-De Bono technique.

  18. Percutaneous Pulmonary Valve Placement

    PubMed Central

    Prieto, Lourdes R.

    2015-01-01

    Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629

  19. Conduit repair for complex congenital heart disease with pulmonary atresia or right ventricular outflow tract obstruction. Part II: early and late hemodynamic and echocardiographic findings.

    PubMed

    Rupprath, G; Vogt, J; de Vivie, E R; Beuren, A J

    1981-12-01

    The results are presented of 44 systematic cardiac catheterizations in 35 patients after successful repair of various types of congenital cyanotic heart disease using a conduit. The operations were performed from 1972 to 1981. The patients were followed from 6 months to 9 years, the mean interval between operation and catheterization was 2.5 years (4 weeks to 8 years). Different types of conduits were used: a Hancock conduit in 27 cases (1 replaced), an aortic homograft in 3 cases (all 3 replaced by a Hancock conduit), a Dacron tube with Lillehei-Kaster valve in 2 cases (1 replaced), a lonescu-Shiley conduit in 5 cases, a composite graft of pericardium and a Hancock valve in one patient (replaced) and a valveless Dacron tube in one patient. The total conduit gradient was differentiated in 43/44 investigations. For the Hancock conduit the mean proximal gradient was 9 mmHg, the valvular 14 and the distal 13 mmHg. Severe valvular stenosis of the porcine valve occurred in 3 patients. For the lonescu-Shiley conduit only early, but promising, results are available. Three of the 35 patients died late (2.5 and 4 years postoperatively); the deaths were related to severe additional lesions. Cross-sectional echocardiography was performed in 32 of the 35 patients. The latter does not appear to be a reliable method for the detection of valvular lesions so far, but is helpful for the diagnosis of proximal and distal obstructions of the conduit.

  20. The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement

    PubMed Central

    McElhinney, Doff B; Hennesen, Jill T

    2013-01-01

    The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411

  1. Mitral valve replacement with the Hancock stabilized glutaraldehyde valve. Clinical and laboratory evaluation.

    PubMed

    Buch, W S; Pipkin, R D; Hancock, W D; Fogarty, T J

    1975-11-01

    From March 1971 through April 1975, one hundred twenty patients underwent mitral valve replacement with a Hancock "stabilized glutaraldehyde process" porcine aortic xenograft. A simultaneous canine experimental series was also carried out. In the clinical series, the early mortality was 8.3%. Actuarial analyses of all patients predicts survival at two years of 81.0% and at four years of 70.0%. The predicted survival for patients without coronary disease or prior prosthetic valve replacement is 87.5% at two years and 77.5% at four years. There were four thromboembolic episodes, a rate of 2.4% per patient-year. None were fatal. No valve failure were noted. Histologic examination and shrink temperature analysis of recovered valves show excellent tissue preservation at 40 months. The data indicate that the Hancock valve is durable, enjoys a low incidence of thromboembolism, and may be the valve of choice for mitral valve replacement.

  2. Cryogenic Cam Butterfly Valve

    NASA Technical Reports Server (NTRS)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  3. Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results.

    PubMed

    Vrandecic, M; Gontijo Filho, B; Fantini, F; Barbosa, J; Martins, I; de Oliveira, O C; Martins, C; Max, R; Drumond, L; Oliveira, C; Ferrufino, A; Alcocer, E; Silva, J A; Vrandecic, E

    1998-03-01

    The study aimed to determine the clinical performance of bovine pericardial aldehyde-treated products alone or in combination with aortic leaflets of porcine origin. These included a composite porcine stentless aortic valve attached to a scalloped pericardial tube (BSAV), and valved and non-valved bovine pericardial conduits for use in left-sided heart lesions (BPG). For BSAV grafts, between January 1990 and August 1996, 163 patients (119 males) had their aortic valves replaced by SJM Biocor BASV. Mean age was 37.9 +/- 17.6 years (range: 1 to 76 years). Rheumatic heart disease sequelae (n = 72) and replacement of a prosthetic heart valve (n = 46) were predominant. Preoperative NYHA functional class showed 90 patients (55.2%) in class III and 50 (30.7%) in class IV. BPVC and NVPC grafts were used in 166 patients: acute aortic dissection was the main indication in 52 (31.3%) and chronic in 36 (21/7%). The ascending aorta was involved in 141 patients (84.9%); grafts were seldom used at other sites. In most patients the graft implanted was either a non-valved (n = 79) or a valved (n = 75) pericardial conduit. Twelve patients had a localized lesion and required a patch repair. For BASV grafts, the non-valve-related hospital mortality rate was 4.9%. There were 14.7% non-fatal complications with full recovery of all patients. Mean follow up in 141 patients was 3.0 +/- 1.4 years (range: 1 month to 7.2 years); 14 patients were lost to follow up. Late, non-conduit-related, mortality occurred in seven patients (4.9%). Eight patients underwent reoperation. The current clinical follow up of 127 patients has shown 118 (92.9%) with competent valves and nine (7.0%) with mild stable aortic insufficiency. For BPVC and NVPC grafts, hospital mortality rate was 16.9%, death being related to poor preoperative clinical condition. Postoperative follow up was accomplished in 125 patients; reoperation was necessary in seven patients. Histology showed good tissue preservation up to five

  4. Rapid 3D printing of anatomically accurate and mechanically heterogeneous aortic valve hydrogel scaffolds

    PubMed Central

    Hockaday, L A; Kang, K H; Colangelo, N W; Cheung, P Y C; Duan, B; Malone, E; Wu, J; Girardi, L N; Bonassar, L J; Lipson, H; Chu, C C; Butcher, J T

    2013-01-01

    The aortic valve exhibits complex three-dimensional (3D) anatomy and heterogeneity essential for long-term efficient biomechanical function. These are, however, challenging to mimic in de novo engineered living tissue valve strategies. We present a novel simultaneous 3D-printing/photocrosslinking technique for rapidly engineering complex, heterogeneous aortic valve scaffolds. Native anatomic and axisymmetric aortic valve geometries (root wall and tri-leaflets) with 12 to 22 mm inner diameters (ID) were 3D printed with poly-ethylene glycol-diacrylate (PEG-DA) hydrogels (700 or 8000 MW) supplemented with alginate. 3D printing geometric accuracy was quantified and compared using Micro-CT. Porcine aortic valve interstitial cells (PAVIC) seeded scaffolds were cultured for up to 21 days. Results showed that blended PEG-DA scaffolds could achieve over 10-fold range in elastic modulus (5.3±0.9 to 74.6±1.5 kPa). 3D printing times for valve conduits with mechanically contrasting hydrogels were optimized to 14 to 45 minutes, increasing linearly with conduit diameter. Larger printed valves had greater shape fidelity (93.3±2.6, 85.1±2.0, and 73.3±5.2% for 22, 17, and 12 mm ID porcine valves; 89.1±4.0, 84.1±5.6, and 66.6±5.2% for simplified valves). PAVIC seeded scaffolds maintained near 100% viability over 21 days. These results demonstrate that 3D hydrogel printing with controlled photocrosslinking can rapidly fabricate anatomical heterogeneous valve conduits that support cell engraftment. PMID:22914604

  5. Apico-Aortic Conduit for severe aortic stenosis: Technique, applications, and systematic review

    PubMed Central

    Elmistekawy, Elsayed; Lapierre, Harry; Mesana, Thierry; Ruel, Marc

    2010-01-01

    Patients referred for aortic valve replacement are often elderly and may have increased surgical risk associated with ascending aortic calcification, left ventricular dysfunction, presence of coronary artery disease, previous surgery, and/or presence of several co-morbidities. Some of these patients may not be considered candidates for conventional surgery because of their high risk profile. While transcatheter aortic valve replacement constitutes a widely accepted alternative, some patients may not be eligible for this modality due to anatomic factors. Apico-Aortic Conduit (AAC) insertion (aortic valve bypass surgery) constitutes a possible option in those patients. Apico-Aortic Conduit is not a new technique, as it has been used for decades in both pediatric and adult populations. However, there is a resurging interest in this technique due to the expanding scope of elderly patients being considered for the treatment of aortic stenosis. Herein, we describe our surgical technique and provide a systematic review of recent publications on AAC insertion, reporting that there is continued use and several modifications of this technique, such as performing it through a small thoracotomy without the use of the cardiopulmonary bypass. PMID:23960619

  6. High speed exhaust gas recirculation valve

    DOEpatents

    Fensom, Rod; Kidder, David J.

    2005-01-18

    In order to minimize pollutants such as Nox, internal combustion engines typically include an exhaust gas recirculation (EGR) valve that can be used to redirect a portion of exhaust gases to an intake conduit, such as an intake manifold, so that the redirected exhaust gases will be recycled. It is desirable to have an EGR valve with fast-acting capabilities, and it is also desirable to have the EGR valve take up as little space as possible. An exhaust gas recirculation valve is provided that includes an exhaust passage tube, a valve element pivotally mounted within the exhaust passage tube, a linear actuator; and a gear train. The gear train includes a rack gear operatively connected to the linear actuator, and at least one rotatable gear meshing with the rack gear and operatively connected to the valve element to cause rotation of the valve element upon actuation of the linear actuator. The apparatus provides a highly compact package having a high-speed valve actuation capability.

  7. Three dimensional rotational angiography for assessment of coronary arteries during melody valve implantation: introducing a technique that may improve outcomes.

    PubMed

    Pockett, C R; Moore, J W; El-Said, H G

    2017-02-01

    Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.

  8. Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial

    PubMed Central

    McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.

    2014-01-01

    Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID

  9. The early and midterm function of decellularized aortic valve allografts.

    PubMed

    da Costa, Francisco D A; Costa, Ana Claudia B A; Prestes, Roberta; Domanski, Ana Carolina; Balbi, Eduardo Mendel; Ferreira, Andreia D A; Lopes, Sergio Veiga

    2010-12-01

    This study evaluates the early and midterm results of decellularized aortic valve allografts (DAVA) as an aortic valve replacement. Between October 2005 and February 2010, 41 patients, 28 of whom were male, with a median age of 34 years (range, 0.1 to 71), had aortic valve replacement with DAVA. Decellularization was obtained with a 0.1% sodium dodecyl sulfate solution. Postoperative evaluation was performed with serial echocardiograms, magnetic resonance imaging, and multislice computed tomography studies to evaluate valve hemodynamics, allograft conduit dimensions, and calcification scores. There were 3 early deaths and 1 late death, with a mean follow-up of 19 months (range, 1 to 53). There was 1 reoperation due to a failed mitral valve repair. By echocardiography in all patients, the median immediate postoperative peak gradient was 7 mm Hg (range, 1 to 26 mm Hg), and at last follow-up it was 4 mm Hg (range, 1 to 16 mm Hg); valvular regurgitation was graded as none or trivial in all but 1 patient, who had a regurgitation graded as mild to moderate. By magnetic resonance imaging (n = 4), mean root dimensions were stable at the annulus (24 mm), sinus of Valsalva (33 mm), and sinotubular junction (28 mm). By computed tomography (n = 22), there was only discrete conduit calcification (median calcium score 63 Hounsfield units [HU]; range, 0 to 894 HU) to 3 years of follow-up. Conduit biopsy in the patient who underwent reoperation demonstrated well-preserved wall structure, absence of calcification, and limited in vivo host repopulation. The early and midterm results with DAVA demonstrated stable structural integrity, low rate of calcification, and adequate hemodynamics. Although longer periods of observation are necessary, DAVA appears to be a promising alternative for aortic valve replacement in selected patients. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Anesthetic Considerations for Transcatheter Pulmonary Valve Replacement.

    PubMed

    Gregory, Stephen H; Zoller, Jonathan K; Shahanavaz, Shabana; Chilson, Kelly L; Ridley, Clare H

    2018-02-01

    The introduction of transcatheter therapy for valvular heart disease has revolutionized the care of patients with valvular disorders. Pathologic regurgitation or stenosis of the pulmonary valve, right ventricular outflow tract, or a right ventricle-to-pulmonary artery conduit represent emerging indications for transcatheter therapy. To date, minimal literature exists detailing the anesthetic management of patients undergoing transcatheter pulmonary valve replacement. In this review, the pathophysiology and indications for transcatheter pulmonary valve replacement and possible complications unique to this procedure are reviewed. Anesthetic management, including preoperative assessment, intraoperative considerations, and early postoperative monitoring, are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves.

    PubMed

    Valente, M; Minarini, M; Maizza, A F; Bortolotti, U; Thiene, G

    1992-01-01

    Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Recurrent prosthetic valve endocarditis caused by Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus)

    PubMed Central

    Uhrin, Gábor Balázs; Jensen, Rasmus Hare; Korup, Eva; Grønlund, Jens; Hjort, Ulla; Moser, Claus; Arendrup, Maiken Cavling; Schønheyder, Henrik Carl

    2015-01-01

    We report Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus) causing recurrent prosthetic valve endocarditis. The fungus was the sole agent detected during replacement of a mechanical aortic valve conduit due to abscess formation. Despite extensive surgery and anti-fungal treatment, the patient had a cerebral hemorrhage 4 months post-surgery prompting a diagnosis of recurrent prosthetic valve endocarditis and fungemia. PMID:26909244

  13. MR and CT imaging of pulmonary valved conduits in children and adolescents: normal appearance and complications.

    PubMed

    Tenisch, Estelle V; Alamo, Leonor T; Sekarski, Nicole; Hurni, Michel; Gudinchet, François

    2014-12-01

    The Contegra® is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. To describe both normal and pathological appearances of the Contegra® in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra® conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. CT and MR work-up showed Contegra® stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra® in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra®. CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up.

  14. Homograft conduit failure in infants is not due to somatic outgrowth.

    PubMed

    Wells, Winfield J; Arroyo, Hector; Bremner, Ross M; Wood, John; Starnes, Vaughn A

    2002-07-01

    It has been assumed that the need for homograft replacement is due to somatic outgrowth, but this has not been adequately studied. Our objective was to identify reasons for homograft conduit failure. The records and imaging studies of 40 patients undergoing homograft conduit replacement of the right ventricular outflow tract from 1996 to 2000 were retrospectively reviewed. The majority of patients had a diagnosis of tetralogy of Fallot (n = 20) and truncus arteriosus (n = 13). The median age at the initial operation was 8 months (0.25-108 months). The initial homograft sizes ranged from 9 to 22 mm, and 28 conduits were of pulmonary origin. When comparing size of the initial homograft with patients' expected pulmonary valve diameter (z = 0), oversizing was noted to be +3 (range, 0.83-5.4). Median interval to conduit failure was 5.3 years (0.83-11.3 years). At homograft replacement, only 12 patients had an existing conduit that was 1 SD below the homograft conduit size needed (z < or = -1). Most conduits had important regurgitation, but this was rarely a primary reason for reintervention (n = 1). Reoperation was usually required for stenosis, with a median gradient of 53 mm Hg (20-140 mm Hg). Stenosis was further categorized angiographically as follows: homograft valvular stenosis (shrinkage; 21/40 [53%]), distal anastomotic stenosis (4/40 [10%]), conduit kinking (3/40 [8%]), sternal compression (3/40 [8%]), posterior shelf impingement (2/40 [5%]), and somatic outgrowth (3/40 [8%]). Replacement in 2 patients was for proximal hood aneurysm. Several patients (7/40 [18%]) had stenosis at multiple levels. The average decrease in conduit diameter was 47% (28%-73%). Somatic outgrowth is seldom a primary reason for homograft conduit replacement of the right ventricular outflow tract. The most common cause for failure is conduit obstruction with thickening and shrinkage at the annular area. Conduit stenosis was responsible for failure in 53% of patients, technical issues

  15. A novel balloon assisted two-stents telescoping technique for repositioning an embolized stent in the pulmonary conduit.

    PubMed

    Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J

    2014-08-01

    A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.

  16. Depressurization valve

    DOEpatents

    Skoda, G.I.

    1989-03-28

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring-preferably of the Belleville variety-acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion.

  17. [Percutaneous stented pulmonary valve implantation].

    PubMed

    Ersbøll, Mads; Søndergaard, Lars

    2010-03-29

    A number of congenital cardiac malformations involve the right ventricular outflow tract and are often treated with a biological valved conduit. The longevity of these valves is limited due to graft degeneration, which causes progressive valvular dysfunction and subsequently right ventricular failure. Due to the young age of these patients, repeat surgery can be expected and this has motivated the invention of the percutaneous stented valve implantation (PPVR). We retrospectively examined 13 patients (mean age 26 +/- 10 years) treated with PPVR between 2006 and 2008 at our institution. Indications for PPVR were conduit dysfunction with severe stenosis and/or regurgitation, reduced exercise capacity and right ventricular dilatation. In all patients, immediate haemodynamic improvement occurred with full valvular competence after PPVR. The pressure gradient was reduced from 43 (+/- 15) mmHg to 12 (+/- 7) mmHg (p = 0,05) in patients with combined regurgitation and stenosis and 47 (+/- 14) mmHg to 12 (+/- 2) mmHg (p = 0,05) in patients with isolated stenosis. At mean follow-up after 141 (+/- 140) days, no reintervention had been required. Significant haemodynamic and clinical improvement occurred after PPVR in all patients and no major complications occurred. PPVR remains a safe and minimally invasive treatment modality, and our study demonstrates that PPVR can be safely performed in a low volume setting.

  18. Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.

    PubMed

    McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E

    2011-12-01

    Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (P<0.001), whereas TPV compression (P=0.01) and apposition to the anterior chest wall (P=0.02) were associated with shorter freedom from MSF. Freedom from RVOT reintervention was 86±4% at 27 months. Among patients with a MSF, freedom from RVOT reintervention after MSF diagnosis was 49±10% at 2 years. Factors associated with reintervention were similar to those for MSF. MSF was common after TPV implant in this multicenter experience and was more likely in patients with severely obstructed RVOT conduits and when the TPV was directly behind the anterior chest wall and/or clearly compressed. A TPV implant site protected by a prestent or bioprosthetic valve was associated with lower risk of MSF and reintervention.

  19. Extracardiac conduit obstruction: initial experience in the use of Doppler echocardiography for noninvasive estimation of pressure gradient.

    PubMed

    Reeder, G S; Currie, P J; Fyfe, D A; Hagler, D J; Seward, J B; Tajik, A J

    1984-11-01

    Extracardiac valved conduits are often employed in the repair of certain complex congenital heart defects; late obstruction is a well recognized problem that usually requires catheterization for definitive diagnosis. A reliable noninvasive method for detecting conduit stenosis would be clinically useful in identifying the small proportion of patients who develop this problem. Continuous wave Doppler echocardiography has been used successfully to estimate cardiac valvular obstructive lesions noninvasively. Twenty-three patients with prior extracardiac conduit placement for complex congenital heart disease underwent echocardiographic and continuous wave Doppler echocardiographic examinations to determine the presence and severity of conduit stenosis. In 20 of the 23 patients, an adequate conduit flow velocity profile was obtained, and in 10 an abnormally increased conduit flow velocity was present. All but one patient had significant obstruction proven at surgery and in one patient, surgery was planned. In three patients, an adequate conduit flow velocity profile could not be obtained but obstruction was still suspected based on high velocity tricuspid regurgitant Doppler signals. In these three patients, subsequent surgery also proved that conduit stenosis was present. Doppler-predicted gradients and right ventricular pressures showed an overall good correlation (r = 0.90) with measurements at subsequent cardiac catheterization. Continuous wave Doppler echocardiography appears to be a useful noninvasive tool for the detection and semiquantitation of extracardiac conduit stenosis.

  20. Depressurization valve

    DOEpatents

    Skoda, George I.

    1989-01-01

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring--preferably of the Belleville variety--acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion. The latch plate in surrounding the stem is limited in its outward movement by a boss attached to the stem at the end of

  1. Nucleotide Catabolism on the Surface of Aortic Valve Xenografts; Effects of Different Decellularization Strategies.

    PubMed

    Kutryb-Zajac, Barbara; Yuen, Ada H Y; Khalpey, Zain; Zukowska, Paulina; Slominska, Ewa M; Taylor, Patricia M; Goldstein, Steven; Heacox, Albert E; Lavitrano, Marialuisa; Chester, Adrian H; Yacoub, Magdi H; Smolenski, Ryszard T

    2016-04-01

    Extracellular nucleotide metabolism controls thrombosis and inflammation and may affect degeneration and calcification of aortic valve prostheses. We evaluated the effect of different decellularization strategies on enzyme activities involved in extracellular nucleotide metabolism. Porcine valves were tested intact or decellularized either by detergent treatment or hypotonic lysis and nuclease digestion. The rates of ATP hydrolysis, AMP hydrolysis, and adenosine deamination were estimated by incubation of aorta or valve leaflet sections with substrates followed by HPLC analysis. We demonstrated relatively high activities of ecto-enzymes on porcine valve as compared to the aortic wall. Hypotonic lysis/nuclease digestion preserved >80 % of ATP and AMP hydrolytic activity but reduced adenosine deamination to <10 %. Detergent decellularization completely removed (<5 %) all these activities. These results demonstrate high intensity of extracellular nucleotide metabolism on valve surface and indicate that various valve decellularization techniques differently affect ecto-enzyme activities that could be important in the development of improved valve prostheses.

  2. Testing of RPMI-1640 as a Nutrient Medium for Fresh Semilunar Valve Storage.

    DTIC Science & Technology

    1979-01-01

    familiarization with cage life, canine distemper and hepatitis vaccinations, worming for internal parasites, and obtain one normal complete blood count. Atropine...human valves. If these results are similar to this canine study, a more realistic evaluation can be made as to whether the best tissue for heart valve...replacement is from live tissue of human allografts or dead tissue of procine xenografts. I SUMMARY The medium selected to store canine heart valves

  3. Portable conduit retention apparatus for releasably retaining a conduit therein

    DOEpatents

    Metzger, Richard H.

    1998-01-01

    Portable conduit retention apparatus for releasably retaining a conduit therein. The apparatus releasably retains the conduit out of the way of nearby personnel and equipment. The apparatus includes a portable support frame defining a slot therein having an open mouth portion in communication with the slot for receiving the conduit through the open mouth portion and into the slot. A retention bar is pivotally connected to the support frame adjacent the mouth portion for releasably retaining the conduit in the slot. The retention bar freely pivots to a first position, so that the mouth portion is unblocked in order that the conduit is received through the mouth portion and into the slot. In addition, the retention bar freely pivots to a second position, so that the mouth portion is blocked in order that the conduit is retained in the slot. The conduit is released from the slot by pivoting the retention bar to the first position to unblock the mouth portion and thereafter manipulating the conduit from the slot and through the mouth portion. The apparatus may further include a mounting member attached to the support frame for mounting the apparatus on a vertical support surface. Another embodiment of the apparatus includes a shoe assembly of predetermined weight removably connected to the support frame for resting the apparatus on a floor in such a manner that the apparatus is substantially stationary on the floor.

  4. Portable conduit retention apparatus for releasably retaining a conduit therein

    DOEpatents

    Metzger, R.H.

    1998-07-07

    Portable conduit retention apparatus is described for releasably retaining a conduit therein. The apparatus releasably retains the conduit out of the way of nearby personnel and equipment. The apparatus includes a portable support frame defining a slot therein having an open mouth portion in communication with the slot for receiving the conduit through the open mouth portion and into the slot. A retention bar is pivotally connected to the support frame adjacent the mouth portion for releasably retaining the conduit in the slot. The retention bar freely pivots to a first position, so that the mouth portion is unblocked in order that the conduit is received through the mouth portion and into the slot. In addition, the retention bar freely pivots to a second position, so that the mouth portion is blocked in order that the conduit is retained in the slot. The conduit is released from the slot by pivoting the retention bar to the first position to unblock the mouth portion and thereafter manipulating the conduit from the slot and through the mouth portion. The apparatus may further include a mounting member attached to the support frame for mounting the apparatus on a vertical support surface. Another embodiment of the apparatus includes a shoe assembly of predetermined weight removably connected to the support frame for resting the apparatus on a floor in such a manner that the apparatus is substantially stationary on the floor. 6 figs.

  5. Failing stentless Bioprostheses in patients with carcinoid heart valve disease.

    PubMed

    Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut

    2015-03-27

    Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.

  6. Decellularized heart valve as a scaffold for in vivo recellularization: deleterious effects of granulocyte colony-stimulating factor.

    PubMed

    Juthier, Francis; Vincentelli, André; Gaudric, Julien; Corseaux, Delphine; Fouquet, Olivier; Calet, Christine; Le Tourneau, Thierry; Soenen, Valérie; Zawadzki, Christophe; Fabre, Olivier; Susen, Sophie; Prat, Alain; Jude, Brigitte

    2006-04-01

    Autologous recellularization of decellularized heart valve scaffolds is a promising challenge in the field of tissue-engineered heart valves and could be boosted by bone marrow progenitor cell mobilization. The aim of this study was to examine the spontaneous in vivo recolonization potential of xenogeneic decellularized heart valves in a lamb model and the effects of granulocyte colony-stimulating factor mobilization of bone marrow cells on this process. Decellularized porcine aortic valves were implanted in 12 lambs. Six lambs received granulocyte colony-stimulating factor (10 microg x kg(-1) x d(-1) for 7 days, granulocyte colony-stimulating factor group), and 6 received no granulocyte colony-stimulating factor (control group). Additionally, nondecellularized porcine valves were implanted in 5 lambs (xenograft group). Angiographic and histologic evaluation was performed at 3, 6, 8, and 16 weeks. Few macroscopic modifications of leaflets and the aortic wall were observed in the control group, whereas progressive shrinkage and thickening of the leaflets appeared in the granulocyte colony-stimulating factor and xenograft groups. In the 3 groups progressive ovine cell infiltration (fluorescence in situ hybridization) was observed in the leaflets and in the adventitia and the intima of the aortic wall but not in the media. Neointimal proliferation of alpha-actin-positive cells, inflammatory infiltration, adventitial neovascularization, and calcifications were more important in the xenograft and the granulocyte colony-stimulating factor groups than in the control group. Continuous re-endothelialization appeared only in the control group. Decellularized xenogeneic heart valve scaffolds allowed partial autologous recellularization. Granulocyte colony-stimulating factor led to accelerated heart valve deterioration similar to that observed in nondecellularized xenogeneic cardiac bioprostheses.

  7. In-vivo assessment of the morphology and hemodynamic functions of the BioValsalva™ composite valve-conduit graft using cardiac magnetic resonance imaging and computational modelling technology.

    PubMed

    Kidher, Emaddin; Cheng, Zhuo; Jarral, Omar A; O'Regan, Declan P; Xu, Xiao Yun; Athanasiou, Thanos

    2014-12-09

    The evaluation of any new cardiac valvular prosthesis should go beyond the classical morbidity and mortality rates and involve hemodynamic assessment. As a proof of concept, the objective of this study was to characterise for the first time the hemodynamics and the blood flow profiles at the aortic root in patients implanted with BioValsalva™ composite valve-conduit using comprehensive MRI and computer technologies. Four male patients implanted with BioValsalva™ and 2 age-matched normal controls (NC) underwent cardiac magnetic resonance imaging (MRI). Phase-contrast imaging with velocity-mapping in 3 orthogonal directions was performed at the level of the aortic root and descending thoracic aorta. Computational fluid dynamic (CFD) simulations were performed for all the subjects with patient-specific flow information derived from phase-contrast MR data. The maximum and mean flow rates throughout the cardiac cycle at the aortic root level were very comparable between NC and BioValsalva™ patients (541 ± 199 vs. 567 ± 75 ml/s) and (95 ± 46 vs. 96 ± 10 ml/s), respectively. The maximum velocity (cm/s) was higher in patients (314 ± 49 vs. 223 ± 20; P = 0.06) due to relatively smaller effective orifice area (EOA), 2.99 ± 0.47 vs. 4.40 ± 0.24 cm2 (P = 0.06), however, the BioValsalva™ EOA was comparable to other reported prosthesis. The cross-sectional area and maximum diameter at the root were comparable between the two groups. BioValsalva™ conduit was stiffer than the native aortic wall, compliance (mm2 • mmHg(-1) • 10(-3)) values were (12.6 ± 4.2 vs 25.3 ± 0.4.; P = 0.06). The maximum time-averaged wall shear stress (Pa), at the ascending aorta was equivalent between the two groups, 17.17 ± 2.7 (NC) vs. 17.33 ± 4.7 (BioValsalva™ ). Flow streamlines at the root and ascending aorta were also similar between the two groups apart from a degree of helical flow that occurs at the outer

  8. Prosthetic valve implantation with preservation of the entire valvular and subvalvular apparatus of the tricuspid valve in congenitally corrected transposition of the great arteries.

    PubMed

    Ergenoglu, Mehmet U; Yerebakan, Halit; Ozveren, Olcay; Koner, Ozge; Kalangos, Afksendiyos; Demirsoy, Ergun

    2011-10-01

    Congenitally corrected transposition of the great arteries, which is characterized by atrioventricular and ventriculoarterial discordance, is a rare congenital heart disease. Most of the cases are diagnosed in childhood, owing to associated cardiac anomalies, such as ventricular septal defect, pulmonary stenosis or pulmonary atresia, and Ebstein-like malformation of the tricuspid valve. We present a patient with congenitally corrected transposition of the great arteries who underwent surgical replacement of the tricuspid valve with a bioprosthesis and reconstruction of the left ventricular outflow tract with bovine conduit.

  9. Improving patency of coronary conduits "valveless" veins and/or arterial grafts.

    PubMed

    Lajos, Thomas Z; Robicsek, Francis; Thubrikar, Mano; Urschel, Harold

    2007-01-01

    Veins used for coronary artery bypass operation have a well-documented limited long-term patency. Internal thoracic artery (ITA) grafts have shown exceptional "durability." Assumptions were made that other arterial conduits have similar characteristics. The purpose of this article is to compare different conduits long-term patency including saphenous veins to other available arterial conduits: inferior epigastric artery (IE), right gastroepiploic artery (RGEA), and radial artery (RA). Recent studies have shown that radial artery bypasses have lower patency rate than saphenous veins. Flow patterns, physiological flow characteristics are reviewed including native vessel disease and area of myocardium supplied. In the case of venous bypasses, the primary culprit of failure seemed to be the quality of the vein itself and the reverse venous valves in the conduit resulting in: (a) trapping-hypertension, (b) thrombosis, (c) turbulence, (d) intimal damage, (e) mismatching in size. Clinical follow-up of our patients up to 8 to 11 years (average 8.9 years) have proved the superior characteristics of the so-called "good veins." In a retrospective study of 436 patients sequential, valveless veins patency was 88.6% versus 72% of reversed valvular segments (p < 0.01). Patients' survival seemed to be significantly improved if these veins were combined with ITA grafts. Patients' survival with one valveless limb HS + ITA was 78% versus HS + SV 52% (p < or = 0.0017) and HS + ITA versus HS + ITA + SV (p < 0.0057). Selective decision-making of the surgeon at the time of the operation is required to choose the best conduit to be able to perform the best operation with the best long-term result.

  10. Flowmeter for determining average rate of flow of liquid in a conduit

    DOEpatents

    Kennerly, J.M.; Lindner, G.M.; Rowe, J.C.

    1981-04-30

    This invention is a compact, precise, and relatively simple device for use in determining the average rate of flow of a liquid through a conduit. The liquid may be turbulent and contain bubbles of gas. In a preferred embodiment, the flowmeter includes an electrical circuit and a flow vessel which is connected as a segment of the conduit conveying the liquid. The vessel is provided with a valved outlet and is partitioned by a vertical baffle into coaxial chambers whose upper regions are vented to permit the escape of gas. The inner chamber receives turbulent downflowing liquid from the conduit and is sized to operate at a lower pressure than the conduit, thus promoting evolution of gas from the liquid. Lower zones of the two chambers are interconnected so that the downflowing liquid establishes liquid levels in both chambers. The liquid level in the outer chamber is comparatively calm, being to a large extent isolated from the turbulence in the inner chamber once the liquid in the outer chamber has risen above the liquid-introduction zone for that chamber. Lower and upper probes are provided in the outer chamber for sensing the liquid level therein at points above its liquid-introduction zone. An electrical circuit is connected to the probes to display the time required for the liquid level in the outer chamber to successively contact the lower and upper probes. The average rate of flow through the conduit can be determined from the above-mentioned time and the vessel volume filled by the liquid during that time.

  11. Flowmeter for determining average rate of flow of liquid in a conduit

    DOEpatents

    Kennerly, John M.; Lindner, Gordon M.; Rowe, John C.

    1982-01-01

    This invention is a compact, precise, and relatively simple device for use in determining the average rate of flow of a liquid through a conduit. The liquid may be turbulent and contain bubbles of gas. In a preferred embodiment, the flowmeter includes an electrical circuit and a flow vessel which is connected as a segment of the conduit conveying the liquid. The vessel is provided with a valved outlet and is partitioned by a vertical baffle into coaxial chambers whose upper regions are vented to permit the escape of gas. The inner chamber receives turbulent downflowing liquid from the conduit and is sized to operate at a lower pressure than the conduit, thus promoting evolution of gas from the liquid. Lower zones of the two chambers are interconnected so that the downflowing liquid establishes liquid levels in both chambers. The liquid level in the outer chamber is comparatively calm, being to a large extent isolated from the turbulence in the inner chamber once the liquid in the outer chamber has risen above the liquid-introduction zone for that chamber. Lower and upper probes are provided in the outer chamber for sensing the liquid level therein at points above its liquid-introduction zone. An electrical circuit is connected to the probes to display the time required for the liquid level in the outer chamber to successively contact the lower and upper probes. The average rate of flow through the conduit can be determined from the above-mentioned time and the vessel volume filled by the liquid during that time.

  12. Percutaneous pulmonary valve implantation in patients with dysfunction of a "native" right ventricular outflow tract - Mid-term results.

    PubMed

    Georgiev, Stanimir; Tanase, Daniel; Ewert, Peter; Meierhofer, Christian; Hager, Alfred; von Ohain, Jelena Pabst; Eicken, Andreas

    2018-05-01

    To investigate the feasibility and mid-term results of percutaneous pulmonary valve implantation (PPVI) in patients with conduit free or "native" right ventricular outflow tracts (RVOT). We identified all 18 patients with conduit free or "native" right ventricular outflow tract, who were treated with percutaneous pulmonary valve implantation (PPVI) in our institution. They were divided into two groups - these in whom the central pulmonary artery was used as an anchoring point for the preparation of the landing zone (n=10) for PPVI and these, in whom a pulmonary artery branch was used for this purpose (n=8). PPVI was performed successfully in all patients with significant immediate RVOT gradient and pulmonary regurgitation grade reduction. Four patients had insignificant paravalvular regurgitation. In one patient the valve was explanted after 4months because of bacterial endocarditis. A follow-up of 19 (4-60) months showed sustained good function of the other implanted valves. The MRI indexed right ventricular end diastolic volume significantly decreased from 108(54-174) ml/m 2 before the procedure to 76(60-126) ml/m 2 six months after PPVI, p=0.01. PPVI is feasible with good mid-term results in selected patients with a "native" RVOT without a previously implanted conduit. Creating a stable landing zone with a diameter less than the largest available valve (currently 29mm) is crucial for the technical success of the procedure. Further studies and the development of new devices could widen the indications for this novel treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Spool-type control valve assembly with reduced spool stroke for hydraulic belt-and-pulley type continuously variable transmission

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Itoh, H.; Akashi, T.; Takada, M.

    1987-03-31

    This patent describes a hydraulic control system for controlling a speed ratio of a hydraulically-operated continuously variable transmission of belt-and-pulley type having a variable-diameter pulley and a hydraulic cylinder for changing an effective diameter of the variable diameter-pulley of the transmission. The hydraulic control system includes a speed-ratio control valve assembly for controlling the supply and discharge of a pressurized fluid to and from the hydraulic cylinder to thereby change the speed ratio of the transmission. The speed-ratio control valve assembly comprises: a shift-direction switching valve unit disposed in fluid supply and discharge conduits communicating with the hydraulic cylinder, formore » controlling a direction in which the speed ratio of the transmission is varied; a shift-speed control valve unit of spool-valve type connected to the shift-direction switching valve unit. The shift-speed control valve unit is selectively placed in a first state in which the fluid supply and discharge flows to and from the hydraulic cylinder through the conduits are permitted, or in a second state in which the fluid supply flow is restricted while the fluid discharge flow is inhibited; an actuator means for placing the shift speed control valve unit alternately in the first and second states to control a rate of variation in the speed ratio of the transmission in the direction established by the shift-direction switching valve unit.« less

  14. Perioperative management of a patient with Dandy Walker malformation with tetralogy of Fallot undergoing total correction and fresh homologous pericardial pulmonary valve conduit implantation: Report of a rare case

    PubMed Central

    Datt, Vishnu; Tempe, D. K.; Lalwani, Parin; Aggarwal, Saket; Kumar, Pradeep; Diwakar, Anitha; Tomar, A. S.

    2015-01-01

    Perioperative management of a patient with Dandy–Walker malformation (DWM) with tetralogy of Fallot (TOF), patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP), conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo-peritoneal (VP) shunt should be performed before cardiac surgery. We present the first case report of a 11-month-old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion. PMID:26139758

  15. Perioperative management of a patient with Dandy Walker malformation with tetralogy of Fallot undergoing total correction and fresh homologous pericardial pulmonary valve conduit implantation: Report of a rare case.

    PubMed

    Datt, Vishnu; Tempe, D K; Lalwani, Parin; Aggarwal, Saket; Kumar, Pradeep; Diwakar, Anitha; Tomar, A S

    2015-01-01

    Perioperative management of a patient with Dandy-Walker malformation (DWM) with tetralogy of Fallot (TOF), patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP), conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo-peritoneal (VP) shunt should be performed before cardiac surgery. We present the first case report of a 11-month-old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion.

  16. Conduit purging device and method

    NASA Technical Reports Server (NTRS)

    Wilks, Michael T. (Inventor)

    2011-01-01

    A device for purging gas comprises a conduit assembly defining an interior volume. The conduit assembly comprises a first conduit portion having an open first end and an open second end and a second conduit portion having an open first end and a closed second end. The open second end of the first conduit portion is disposed proximate to the open first end of the second conduit portion to define a weld region. The device further comprises a supply element supplying a gas to the interior volume at a substantially constant rate and a vent element venting the gas from the interior volume at a rate that maintains the gas in the interior volume within a pressure range suitable to hold a weld bead in the weld region in equilibrium during formation of a weld to join the first conduit portion and the second conduit portion.

  17. Valve replacement in children: a challenge for a whole life.

    PubMed

    Henaine, Roland; Roubertie, François; Vergnat, Mathieu; Ninet, Jean

    2012-10-01

    Valvular pathology in infants and children poses numerous challenges to the paediatric cardiac surgeon. Without question, valvular repair is the goal of intervention because restoration of valvular anatomy and physiology using native tissue allows for growth and a potentially better long-term outcome. When reconstruction fails or is not feasible, valve replacement becomes inevitable. Which valve for which position is controversial. Homograft and bioprosthetic valves achieve superior haemodynamic results initially but at the cost of accelerated degeneration. Small patient size and the risk of thromboembolism limit the usefulness of mechanical valves, and somatic outgrowth is an universal problem with all available prostheses. The goal of this article is to address valve replacement options for all four valve positions within the paediatric population. We review current literature and our practice to support our preferences. To summarize, a multitude of opinions and surgical experiences exist. Today, the valve choices that seem without controversy are bioprosthetic replacement of the tricuspid valve and Ross or Ross-Konno procedures when necessary for the aortic valve. On the other hand, bioprostheses may be implanted when annular pulmonary diameter is adequate; if not or in case of right ventricular outflow tract discontinuity, it is better to use a pulmonary homograft with the Ross procedure. Otherwise, a valved conduit. Mitral valve replacement remains the most problematic; the mechanical prosthesis must be placed in the annular position, avoiding oversizing. Future advances with tissue-engineered heart valves for all positions and new anticoagulants may change the landscape for valve replacement in the paediatric population. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  18. Seal between metal and ceramic conduits

    DOEpatents

    Underwood, Richard Paul; Tentarelli, Stephen Clyde

    2015-02-03

    A seal between a ceramic conduit and a metal conduit of an ion transport membrane device consisting of a sealing surface of ceramic conduit, a sealing surface of ceramic conduit, a single gasket body, and a single compliant interlayer.

  19. Effectiveness of rivaroxaban for thromboprophylaxis of prosthetic heart valves in a porcine heterotopic valve model.

    PubMed

    Greiten, Lawrence E; McKellar, Stephen H; Rysavy, Joseph; Schaff, Hartzell V

    2014-05-01

    Warfarin is used to reduce the risk of stroke and thromboembolic complications in patients with mechanical heart valves. Yet, despite frequent blood testing, its poor pharmacokinetic and pharmacodynamic profiles often result in variable therapeutic levels. Rivaroxaban is a direct competitive factor Xa inhibitor that is taken orally. It inhibits the active site of factor Xa without the need for the cofactor antithrombin, and thus, its mechanism of action is differentiated from that of the fractionated heparins and indirect factor Xa inhibitors. No in vivo data exist regarding the effectiveness of rivaroxaban in preventing thromboembolic complications of mechanical heart valves. We tested the hypothesis that rivaroxaban is as effective as enoxaparin for thromboprophylaxis of mechanical valves that use a previously described heterotopic aortic valve porcine model. A modified bileaflet mechanical valved conduit that bypassed the native, ligated descending thoracic aorta was implanted into 30 swine. Postoperatively, the animals were randomly assigned to groups receiving no anticoagulation (n = 10), enoxaparin at 2 mg/kg subcutaneously twice daily (n = 10) or rivaroxaban at 2 mg/kg orally twice daily (n = 10). The amount of valve thrombus was measured on post-implantation day 30 as the primary end point. Quantitative evaluation of radiolabelled platelet deposition on the valve prostheses was done and embolic and haemorrhagic events were measured as secondary end points. Animals with no anticoagulation had a thrombus mean of 759.9 mg compared with 716.8 mg with enoxaparin treatment and 209.6 mg with rivaroxaban treatment (P = 0.05 for enoxaparin vs rivaroxaban). Similarly, the mean number of platelets deposited on the valve prosthesis was lower in the rivaroxaban group (6.13 × 10(9)) than in the enoxaparin group (3.03 × 10(10)) (P = 0.03). In this study, rivaroxaban was more effective than enoxaparin for short-term thromboprophylaxis of mechanical valve prosthetics in

  20. Conduit Stability and Collapse in Explosive Volcanic Eruptions: Coupling Conduit Flow and Failure Models

    NASA Astrophysics Data System (ADS)

    Mullet, B.; Segall, P.

    2017-12-01

    Explosive volcanic eruptions can exhibit abrupt changes in physical behavior. In the most extreme cases, high rates of mass discharge are interspaced by dramatic drops in activity and periods of quiescence. Simple models predict exponential decay in magma chamber pressure, leading to a gradual tapering of eruptive flux. Abrupt changes in eruptive flux therefore indicate that relief of chamber pressure cannot be the only control of the evolution of such eruptions. We present a simplified physics-based model of conduit flow during an explosive volcanic eruption that attempts to predict stress-induced conduit collapse linked to co-eruptive pressure loss. The model couples a simple two phase (gas-melt) 1-D conduit solution of the continuity and momentum equations with a Mohr-Coulomb failure condition for the conduit wall rock. First order models of volatile exsolution (i.e. phase mass transfer) and fragmentation are incorporated. The interphase interaction force changes dramatically between flow regimes, so smoothing of this force is critical for realistic results. Reductions in the interphase force lead to significant relative phase velocities, highlighting the deficiency of homogenous flow models. Lateral gas loss through conduit walls is incorporated using a membrane-diffusion model with depth dependent wall rock permeability. Rapid eruptive flux results in a decrease of chamber and conduit pressure, which leads to a critical deviatoric stress condition at the conduit wall. Analogous stress distributions have been analyzed for wellbores, where much work has been directed at determining conditions that lead to wellbore failure using Mohr-Coulomb failure theory. We extend this framework to cylindrical volcanic conduits, where large deviatoric stresses can develop co-eruptively leading to multiple distinct failure regimes depending on principal stress orientations. These failure regimes are categorized and possible implications for conduit flow are discussed, including

  1. Aortic valve bypass surgery in severe aortic valve stenosis: Insights from cardiac and brain magnetic resonance imaging.

    PubMed

    Mantini, Cesare; Caulo, Massimo; Marinelli, Daniele; Chiacchiaretta, Piero; Tartaro, Armando; Cotroneo, Antonio Raffaele; Di Giammarco, Gabriele

    2018-04-13

    To investigate and describe the distribution of aortic and cerebral blood flow (CBF) in patients with severe valvular aortic stenosis (AS) before and after aortic valve bypass (AVB) surgery. We enrolled 10 consecutive patients who underwent AVB surgery for severe AS. Cardiovascular magnetic resonance imaging (CMR) and brain magnetic resonance imaging were performed as baseline before surgery and twice after surgery. Quantitative flow measurements were obtained using 1.5-T magnetic resonance imaging (MRI) scanner phase-contrast images of the ascending aorta, descending thoracic aorta (3 cm proximally and distally from the conduit-to-aorta anastomosis), and ventricular outflow portion of the conduit. The evaluation of CBF was performed using 3.0-T MRI scanner arterial spin labeling (ASL) through sequences acquired at the gray matter, dorsal default-mode network, and sensorimotor levels. Conduit flow, expressed as the percentage of total antegrade flow through the conduit, was 63.5 ± 8% and 67.8 ± 7% on early and mid-term postoperative CMR, respectively (P < .05). Retrograde perfusion from the level of the conduit insertion in the descending thoracic aorta toward the aortic arch accounted for 6.9% of total cardiac output and 11% of total conduit flow. We did not observe any significant reduction in left ventricular stroke volume at postoperative evaluation compared with preoperative evaluation (P = .435). No differences were observed between preoperative and postoperative CBF at the gray matter, dorsal default-mode network, and sensorimotor levels (P = .394). After AVB surgery in patients with severe AS, cardiac output is split between the native left ventricular outflow tract and the apico-aortic bypass, with two-thirds of the total antegrade flow passing through the latter and one-third passing through the former. In our experience, CBF assessment confirms that the flow redistribution does not jeopardize cerebral blood supply. Copyright © 2018 The

  2. In-body tissue-engineered aortic valve (Biovalve type VII) architecture based on 3D printer molding.

    PubMed

    Nakayama, Yasuhide; Takewa, Yoshiaki; Sumikura, Hirohito; Yamanami, Masashi; Matsui, Yuichi; Oie, Tomonori; Kishimoto, Yuichiro; Arakawa, Mamoru; Ohmuma, Kentaro; Tajikawa, Tsutomu; Kanda, Keiichi; Tatsumi, Eisuke

    2015-01-01

    In-body tissue architecture--a novel and practical regeneration medicine technology--can be used to prepare a completely autologous heart valve, based on the shape of a mold. In this study, a three-dimensional (3D) printer was used to produce the molds. A 3D printer can easily reproduce the 3D-shape and size of native heart valves within several processing hours. For a tri-leaflet, valved conduit with a sinus of Valsalva (Biovalve type VII), the mold was assembled using two conduit parts and three sinus parts produced by the 3D printer. Biovalves were generated from completely autologous connective tissue, containing collagen and fibroblasts, within 2 months following the subcutaneous embedding of the molds (success rate, 27/30). In vitro evaluation, using a pulsatile circulation circuit, showed excellent valvular function with a durability of at least 10 days. Interposed between two expanded polytetrafluoroethylene grafts, the Biovalves (N = 3) were implanted in goats through an apico-aortic bypass procedure. Postoperative echocardiography showed smooth movement of the leaflets with minimal regurgitation under systemic circulation. After 1 month of implantation, smooth white leaflets were observed with minimal thrombus formation. Functional, autologous, 3D-shaped heart valves with clinical application potential were formed following in-body embedding of specially designed molds that were created within several hours by 3D printer. © 2014 Wiley Periodicals, Inc.

  3. Percutaneous pulmonary valve implantation: an update.

    PubMed

    Lurz, Philipp; Bonhoeffer, Philipp; Taylor, Andrew M

    2009-07-01

    The field of percutaneous valvular interventions is one of the most exciting and rapidly developing within interventional cardiology. Percutaneous pulmonary valve implantation (PPVI) represents the first in-human application of these techniques and is a nonsurgical option for treating right ventricular outflow tract/pulmonary trunk dysfunction. With the growing numbers of patients with right ventricle to pulmonary artery conduit dysfunction after repair of congenital heart disease, the importance of a technique with lower morbidity and mortality, good patient acceptance and efficacy, that is comparable to surgery, cannot be underestimated. Over the last 9 years, PPVI has become a feasible, safe and effective treatment for both conduit stenosis and regurgitation. Median follow-up data show good freedom from reoperation and recatheterization and demonstrate that PPVI can postpone open-heart surgery, thereby potentially reducing the number of operations that patients have to undergo within their lifetime. Complications seen after PPVI, in particular stent fractures, can require reintervention in some cases (second stent-in-stent PPVI); however, valve competency remains good, with significant regurgitation during follow-up only seen in the context of occasional endocarditis. Attempts are now being made to prolong the lifespan of the device by reducing the incidence of stent fractures. Further, meticulous patient selection must be maintained to ensure that hemodynamic results are optimized and the safety of the procedure remains high. Finally, new devices have to be developed that will allow for PPVI in dilated, distensible outflow tracts, to offer this nonsurgical treatment option to a larger patient population with congenital heart disease.

  4. Stochastic simulation of karst conduit networks

    NASA Astrophysics Data System (ADS)

    Pardo-Igúzquiza, Eulogio; Dowd, Peter A.; Xu, Chaoshui; Durán-Valsero, Juan José

    2012-01-01

    Karst aquifers have very high spatial heterogeneity. Essentially, they comprise a system of pipes (i.e., the network of conduits) superimposed on rock porosity and on a network of stratigraphic surfaces and fractures. This heterogeneity strongly influences the hydraulic behavior of the karst and it must be reproduced in any realistic numerical model of the karst system that is used as input to flow and transport modeling. However, the directly observed karst conduits are only a small part of the complete karst conduit system and knowledge of the complete conduit geometry and topology remains spatially limited and uncertain. Thus, there is a special interest in the stochastic simulation of networks of conduits that can be combined with fracture and rock porosity models to provide a realistic numerical model of the karst system. Furthermore, the simulated model may be of interest per se and other uses could be envisaged. The purpose of this paper is to present an efficient method for conditional and non-conditional stochastic simulation of karst conduit networks. The method comprises two stages: generation of conduit geometry and generation of topology. The approach adopted is a combination of a resampling method for generating conduit geometries from templates and a modified diffusion-limited aggregation method for generating the network topology. The authors show that the 3D karst conduit networks generated by the proposed method are statistically similar to observed karst conduit networks or to a hypothesized network model. The statistical similarity is in the sense of reproducing the tortuosity index of conduits, the fractal dimension of the network, the direction rose of directions, the Z-histogram and Ripley's K-function of the bifurcation points (which differs from a random allocation of those bifurcation points). The proposed method (1) is very flexible, (2) incorporates any experimental data (conditioning information) and (3) can easily be modified when

  5. Calcification resistance for photooxidatively crosslinked acellular bovine jugular vein conduits in right-side heart implantation.

    PubMed

    Lü, Wei-Dong; Wang, An-Ping; Wu, Zhong-Shi; Zhang, Ming; Hu, Tie-Hui; Lei, Guang-Yan; Hu, Ye-Rong

    2012-10-01

    This study aimed to investigate the effect of decellularization plus photooxidative crosslinking and ethanol pretreatment on bioprosthetic tissue calcification. Photooxidatively crosslinked acellular (PCA) bovine jugular vein conduits (BJVCs) and their photooxidized controls (n = 5 each) were sterilized in a graded concentration of ethanol solutions for 4 h, and used to reconstruct dog right ventricular outflow tracts. At 1-year implantation, echocardiography showed similar hemodynamic performance, but obvious calcification for the photooxidized BJVC walls. Further histological examination showed intense calcium deposition colocalized with slightly degraded elastic fibers in the photooxidized BJVC walls, with sparsely distributed punctate calcification in the valves and other areas of walls. But PCA BJVCs had apparent degradation of elastic fibers in the walls, with only sparsely distributed punctate calcification in the walls and valves. Content assay demonstrated comparable calcium content for the two groups at preimplantation, whereas less calcium for the PCA group in the walls and similar calcium in the valvular leaflets compared with the photooxidized group at 1-year retrieval. Elastin content assay presented the conduit walls of PCA group had less elastin content at preimplantation, but similar content at 1-year retrieval compared with the photooxidized group. Phospholipid analysis showed phospholipid extraction by ethanol for the PCA group was more efficacious than the photooxidized group. These results indicate that PCA BJVCs resist calcification in right-side heart implantation owing to decellularization, further photooxidative crosslinking, and subsequent phospholipid extraction by ethanol at preimplantation. Copyright © 2012 Wiley Periodicals, Inc.

  6. Multiple source/multiple target fluid transfer apparatus

    DOEpatents

    Turner, Terry D.

    1997-01-01

    A fluid transfer apparatus includes: a) a plurality of orifices for connection with fluid sources; b) a plurality of orifices for connection with fluid targets; c) a set of fluid source conduits and fluid target conduits associated with the orifices; d) a pump fluidically interposed between the source and target conduits to transfer fluid therebetween; e) a purge gas conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass a purge gas under pressure; f) a solvent conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass solvent, the solvent conduit including a solvent valve; g) pump control means for controlling operation of the pump; h) purge gas valve control means for controlling operation of the purge gas valve to selectively impart flow of purge gas to the fluid source conduits, fluid target conduits and pump; i) solvent valve control means for controlling operation of the solvent valve to selectively impart flow of solvent to the fluid source conduits, fluid target conduits and pump; and j) source and target valve control means for controlling operation of the fluid source conduit valves and the fluid target conduit valves to selectively impart passage of fluid between a selected one of the fluid source conduits and a selected one of the fluid target conduits through the pump and to enable passage of solvent or purge gas through selected fluid source conduits and selected fluid target conduits.

  7. Multiple source/multiple target fluid transfer apparatus

    DOEpatents

    Turner, T.D.

    1997-08-26

    A fluid transfer apparatus includes: (a) a plurality of orifices for connection with fluid sources; (b) a plurality of orifices for connection with fluid targets; (c) a set of fluid source conduits and fluid target conduits associated with the orifices; (d) a pump fluidically interposed between the source and target conduits to transfer fluid there between; (e) a purge gas conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass a purge gas under pressure; (f) a solvent conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass solvent, the solvent conduit including a solvent valve; (g) pump control means for controlling operation of the pump; (h) purge gas valve control means for controlling operation of the purge gas valve to selectively impart flow of purge gas to the fluid source conduits, fluid target conduits and pump; (i) solvent valve control means for controlling operation of the solvent valve to selectively impart flow of solvent to the fluid source conduits, fluid target conduits and pump; and (j) source and target valve control means for controlling operation of the fluid source conduit valves and the fluid target conduit valves to selectively impart passage of fluid between a selected one of the fluid source conduits and a selected one of the fluid target conduits through the pump and to enable passage of solvent or purge gas through selected fluid source conduits and selected fluid target conduits. 6 figs.

  8. Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions.

    PubMed

    Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T

    2015-01-01

    Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Whereas much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells.

  9. Current Progress in Tissue Engineering of Heart Valves: Multiscale Problems, Multiscale Solutions

    PubMed Central

    Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T.

    2016-01-01

    Introduction Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. Areas covered This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally-derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Expert opinion While much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells. PMID:26027436

  10. Method and apparatus for inspecting conduits

    DOEpatents

    Spisak, Michael J.; Nance, Roy A.

    1997-01-01

    An apparatus and method for ultrasonic inspection of a conduit are provided. The method involves directing a first ultrasonic pulse at a particular area of the conduit at a first angle, receiving the reflected sound from the first ultrasonic pulse, substantially simultaneously or subsequently in very close time proximity directing a second ultrasonic pulse at said area of the conduit from a substantially different angle than said first angle, receiving the reflected sound from the second ultrasonic pulse, and comparing the received sounds to determine if there is a defect in that area of the conduit. The apparatus of the invention is suitable for carrying out the above-described method. The method and apparatus of the present invention provide the ability to distinguish between sounds reflected by defects in a conduit and sounds reflected by harmless deposits associated with the conduit.

  11. Turbulent and Laminar Flow in Karst Conduits Under Unsteady Flow Conditions: Interpretation of Pumping Tests by Discrete Conduit-Continuum Modeling

    NASA Astrophysics Data System (ADS)

    Giese, M.; Reimann, T.; Bailly-Comte, V.; Maréchal, J.-C.; Sauter, M.; Geyer, T.

    2018-03-01

    Due to the duality in terms of (1) the groundwater flow field and (2) the discharge conditions, flow patterns of karst aquifer systems are complex. Estimated aquifer parameters may differ by several orders of magnitude from local (borehole) to regional (catchment) scale because of the large contrast in hydraulic parameters between matrix and conduit, their heterogeneity and anisotropy. One approach to deal with the scale effect problem in the estimation of hydraulic parameters of karst aquifers is the application of large-scale experiments such as long-term high-abstraction conduit pumping tests, stimulating measurable groundwater drawdown in both, the karst conduit system as well as the fractured matrix. The numerical discrete conduit-continuum modeling approach MODFLOW-2005 Conduit Flow Process Mode 1 (CFPM1) is employed to simulate laminar and nonlaminar conduit flow, induced by large-scale experiments, in combination with Darcian matrix flow. Effects of large-scale experiments were simulated for idealized settings. Subsequently, diagnostic plots and analyses of different fluxes are applied to interpret differences in the simulated conduit drawdown and general flow patterns. The main focus is set on the question to which extent different conduit flow regimes will affect the drawdown in conduit and matrix depending on the hydraulic properties of the conduit system, i.e., conduit diameter and relative roughness. In this context, CFPM1 is applied to investigate the importance of considering turbulent conditions for the simulation of karst conduit flow. This work quantifies the relative error that results from assuming laminar conduit flow for the interpretation of a synthetic large-scale pumping test in karst.

  12. Conduit enlargement in an eogenetic karst aquifer

    NASA Astrophysics Data System (ADS)

    Moore, Paul J.; Martin, Jonathan B.; Screaton, Elizabeth J.; Neuhoff, Philip S.

    2010-11-01

    SummaryMost concepts of conduit development have focused on telogenetic karst aquifers, where low matrix permeability focuses flow and dissolution along joints, fractures, and bedding planes. However, conduits also exist in eogenetic karst aquifers, despite high matrix permeability which accounts for a significant component of flow. This study investigates dissolution within a 6-km long conduit system in the eogenetic Upper Floridan aquifer of north-central Florida that begins with a continuous source of allogenic recharge at the Santa Fe River Sink and discharges from a first-magnitude spring at the Santa Fe River Rise. Three sources of water to the conduit include the allogenic recharge, diffuse recharge through epikarst, and mineralized water upwelling from depth. Results of sampling and inverse modeling using PHREEQC suggest that dissolution within the conduit is episodic, occurring only during 30% of 16 sampling times between March 2003 and April 2007. During low flow conditions, carbonate saturated water flows from the matrix to the conduit, restricting contact between undersaturated allogenic water with the conduit wall. When gradients reverse during high flow conditions, undersaturated allogenic recharge enters the matrix. During these limited periods, estimates of dissolution within the conduit suggest wall retreat averages about 4 × 10 -6 m/day, in agreement with upper estimates of maximum wall retreat for telogenetic karst. Because dissolution is episodic, time-averaged dissolution rates in the sink-rise system results in a wall retreat rate of about 7 × 10 -7 m/day, which is at the lower end of wall retreat for telogenetic karst. Because of the high permeability matrix, conduits in eogenetic karst thus enlarge not just at the walls of fractures or pre-existing conduits such as those in telogenetic karst, but also may produce a friable halo surrounding the conduits that may be removed by additional mechanical processes. These observations stress the

  13. The Ross operation: the autologous pulmonary valve in the aortic position.

    PubMed

    Gonzalez-Lavin, L; Robles, A; Graf, D

    1988-03-01

    Aortic valve replacement (AVR) with a pulmonary valve autograft (PVA) was first reported by Donald N. Ross (DNR) in 1967. The expectation of this procedure was to avoid degenerative changes seen in other biological tissue valves such as calcification, attenuation, and rupture of the leaflets. Recent reports by the original investigator's group have confirmed the lack of degenerative changes in PVA. To corroborate their conclusions, the fate of 12 patients undergoing AVR with PVA by one of us (LGL) has been ascertained. From March 1969 to June 1971, 12 patients underwent AVR with PVA. The right ventricular outflow tract (RVOT) was reconstructed with an aortic homograft valved conduit. The mean age was 42.7 years (range 21 to 52 years). The mean follow-up for 11 hospital survivors is 12.4 years. Three PVA have been replaced; one following infective endocarditis at 13 years, and two at 15 and 73 months due to technical malalignment. There was no evidence of PVA degeneration during histological examination of these explanted PVAs. Six patients are alive and retain the original PVA at 12 years (55%). This analysis corroborates the conclusions of the DNR report and strongly suggests an immunological mechanism in the process of calcification of other biological tissue valves. The Ross operation is advocated for AVR in young patients as valve durability is of paramount importance especially in this group.

  14. Development of decellularized aortic valvular conduit coated by heparin-SDF-1α multilayer.

    PubMed

    Zhou, Jingxin; Ye, Xiaofeng; Wang, Zhe; Liu, Jun; Zhang, Busheng; Qiu, Jiapei; Sun, Yanjun; Li, Haiqing; Zhao, Qiang

    2015-02-01

    Decellularization can reduce the immune response to aortic valve allograft tissue, but the thrombogenicity and in vivo remolding of these grafts remain controversial. The aim of the present study was to modify the surface of decellularized valvular conduits with heparin-stromal cell-derived factor-1α (SDF-1α) polyelectrolyte multilayer film and to test the thrombogenicity and biocompatibility in vitro and recellularization in vivo. The donor aortic valvular conduits were decellularized with a combination of different detergents and were coated with heparin and SDF-1α alternately to form a polyelectrolyte multilayer. Platelet adhesion and lactate dehydrogenase assay were used to evaluate the antiplatelet property. The adhesion, growth, and migration of bone marrow stem cells (BMSCs) to the scaffolds were assessed. For in vivo studies, the grafts were anastomosed to the infrarenal aorta, without or with heparin and SDF-1α multilayer. Functional assessment was performed by Doppler echography and micro-computed tomography at 2-week and 4-week time points after implantation. Explanted grafts were examined histologically and by immunohistochemistry. In vitro studies demonstrated that the heparin-SDF-1α multilayer film improved hemocompatibility with respect to a substantial reduction of platelet adhesion. BMSCs also achieved better adhesion, proliferation, and migration on the modified graft. For in vivo studies, the grafts in both groups remained patent after 4 weeks, but it was demonstrated that the modified decellularized grafts had better self-endothelialization and recruitment of endothelial progenitor cells. These results indicate that heparin-SDF-1α multilayer film can be used to cover the decellularized aortic valvular graft to decrease platelet adhesion while precipitating regeneration of the decellularized aortic valve allograft in vivo. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Collagen incorporation within electrospun conduits reduces lipid oxidation and impacts conduit mechanics.

    PubMed

    Birthare, Karamveer; Shojaee, Mozhgan; Jones, Carlos Gross; Brenner, James R; Bashur, Chris A

    2016-04-21

    Modulating the host response, including the accumulation of oxidized lipid species, is important for improving tissue engineered vascular graft (TEVG) viability. Accumulation of oxidized lipids promotes smooth muscle cell (SMC) hyper-proliferation and inhibits endothelial cell migration, which can lead to several of the current challenges for small-diameter TEVGs. Generating biomaterials that reduce lipid oxidation is important for graft survival and this assessment can provide a reliable correlation to clinical situations. In this study, we determined the collagen to poly(ε-caprolactone) (PCL) ratio required to limit the production of pro-inflammatory species, while maintaining the required mechanical strength for the graft. Electrospun conduits were prepared from 0%, 10%, and 25% blends of collagen/PCL (w/w) and implanted in the rat peritoneal cavity for four weeks. The results showed that adding collagen to the PCL conduits reduced the accumulation of oxidized lipid species within the implanted conduits. In addition, the ratio of collagen had a significant impact on the recruited cell phenotype and construct mechanics. All conduits exhibited greater than 44% yield strain and sufficient tensile strength post-implantation. In conclusion, these results demonstrate that incorporating collagen into synthetic electrospun scaffolds, both 10% and 25% blend conditions, appears to limit the pro-inflammatory characteristics after in vivo implantation.

  16. Simvastatin does not diminish the in vivo degeneration of decellularized aortic conduits.

    PubMed

    Assmann, Alexander; Horstkötter, Kim; Munakata, Hiroshi; Schiffer, Franziska; Delfs, Christofer; Zwirnmann, Kai; Barth, Mareike; Akhyari, Payam; Lichtenberg, Artur

    2014-10-01

    All present biological cardiovascular prostheses are prone to progressive in vivo degeneration, which can be partially impaired by decellularization. The administration of statins may provide an additional beneficial effect. We provide the first in vivo data on the effect of statins on decellularized cardiovascular implants. Wistar rats with aortic valve insufficiency (day 14) were fed either with a pro-calcific diet (group C; n = 17), or the same diet additionally supplemented with simvastatin (group S; n = 16). Aortic conduits from Sprague-Dawley rats were detergent-decellularized, infrarenally implanted (day 0) in all recipients and explanted at day 28 or day 84. Sonographic competence of the conduit perfusion was 100%, and overall survival amounted to 97%. Simvastatin decreased the low-density lipoprotein cholesterol serum levels; however, it did not affect the calcification of the implants. Histology revealed alpha-smooth muscle actin-positive intima hyperplasia in both groups. Extensive matrix metalloproteinase activity was observed in calcified areas, especially in group S. Quantitative RNA analysis resulted in no differences with regard to several markers of calcifying degeneration (alkaline phosphatase, osteopontin, osteocalcin, osteoprotegerin, bone morphogenetic protein-2, runt-related transcription factor-2) and inflammation (tumor necrosis factor α, interleukin 1β, receptor for advanced glycation end products, CD39, CD73), but significantly lower levels of interleukin-6 in group S. In a standardized small animal model of accelerated cardiovascular calcification, simvastatin failed to diminish the calcification of decellularized aortic conduit implants. This finding confirms the observations of recent clinical trials. However, further experiments are warranted to elucidate the value of partial benefits associated with lower circulating lipid and proinflammatory cytokine levels.

  17. [Experience of Mitral Valve Replacement Using a Pulmonary Autograft (Ross II Operation) in an Infant;Report of a Case].

    PubMed

    Kawahito, Tomohisa; Egawa, Yoshiyasu; Yoshida, Homare; Shimoe, Yasushi; Onishi, Tatsuya; Miyagi, Yuhichi; Terada, Kazuya; Ohta, Akira

    2015-07-01

    A 24-day-old boy suddenly developed progressive heart failure and was transported to our hospital. Echocardiography showed massive mitral regurgitation due to chordal rupture. Mitral valve repair was performed at 28 days of life, but postoperative valvular function was not satisfactory. A mechanical valve was implanted in the supra-annular position at 37 days of life. Two months after valve replacement, the mechanical valve was suddenly stuck. Emergent redo valve replacement was performed, but the prosthetic valve became stuck again 2 months after the 3rd operation, despite sufficient anti-coagulation therapy. At the 4th operation (6 months after birth), we implanted a pulmonary autograft in the mitral position instead of another mechanical valve in an emergent operation. The right ventricular outflow tract was reconstructed with a valved conduit. A postoperative catheter examination, which was performed 1 year after the Ross II operation, showed mild mitral stenosis with no regurgitation. Previous reports of Ross II operations in infants are rare and long-term results are unknown. However, we advocate that this procedure should be a rescue operation for mitral valve dysfunction in the early period of infants.

  18. Conduit grinding apparatus

    DOEpatents

    Nachbar, Henry D.; Korytkowski, Alfred S.

    1991-01-01

    A grinding apparatus for grinding the interior portion of a valve stem receiving area of a valve. The apparatus comprises a faceplate, a plurality of cams mounted to an interior face of the faceplate, a locking bolt to lock the faceplate at a predetermined position on the valve, a movable grinder and a guide tube for positioning an optical viewer proximate the area to be grinded. The apparatus can either be rotated about the valve for grinding an area of the inner diameter of a valve stem receiving area or locked at a predetermined position to grind a specific point in the receiving area.

  19. Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.

    PubMed

    O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel

    2017-03-01

    Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.

  20. Performance of stented biological valves for right ventricular outflow tract reconstruction.

    PubMed

    Buchholz, Christian; Mayr, Andreas; Purbojo, Ariawan; Glöckler, Martin; Toka, Okan; Cesnjevar, Robert A; Rüffer, André

    2016-12-01

    This retrospective single-centre review presents mid- and long-term results of stented biological valves (SBVs) in the pulmonary position. Fifty-two SBVs (17 Carpentier-Edwards Supraannular; 13 Carpentier-Edwards Perimount; 12 St. Jude Medical Trifecta; 4 Sorin Mitroflow; 4 Sorin Soprano; 2 Sorin More) were implanted between 2000 and 2015. The median valve size, patient age and weight were 23 mm (range 19-27), 22.8 years (range 5-77) and 62.0 kg (range 14-110), respectively. The main cardiac diagnosis was tetralogy of Fallot in 26 patients (50%). Forty-four patients (85%) had previous cardiac surgery; 12 patients (23%) had previous conduit or biological valve replacement. Valve degeneration was defined as a valvular peak pressure gradient >50 mmHg or pulmonary valve regurgitation more than moderate. The mean follow-up was 7.9 ± 5.5 years. Two patients died after 5.8 and 6.1 years of causes not related to SBVs. Eleven SBVs (21%) had to be replaced surgically (n = 6) or interventionally (n = 5) after 9.0 ± 4.1 years due to valve degeneration (n = 8), endocarditis (n = 2) or right ventricular dysfunction (n = 1). The rates of freedom from valve replacement were 100%, 92% [95% confidence interval (CI) 79-97], 81% (CI 64-91) and 60% (CI 40-78) after 1, 5, 10 and 15 years, respectively. Successful interventional valve-in-valve implantation resulted in 100% freedom from surgical valve replacement in all patients older than 19.1 years. Multivariate analysis identified patient age <19.1 years (P = 0.007) as a risk factor for earlier valve degeneration. SBVs in the pulmonary position showed encouraging long-term results in mature patients. The design of SBVs enables interventional valve implantation, postponing the need for reoperation. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. EVALUATION OF BURIED CONDUITS AS PERSONNEL SHELTERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albright, G.H.; LeDoux, J.C.; Mitchell, R.A.

    1960-07-14

    Supersedes ITR-1421. Twelve large-diameter buried conduit sections of various shapes were tested in the 60- to l49-psi overpressure region of Burst Priscilla to make an empirical determination of the degree of personnel protection afforded by commercially available steel and concrete conduits at depths of burial of 5, 7.5, and 10 feet below grade. Essentially, it was desired to assure that Repartment of Defense Class I, 100psi and comparable radiations, and Class II, 50-psi and comparable radiations, protection is afforded by use of such conduits of various configurations. Measurements were made of free-field overpressure at the ground surface above the structure;more » pressure inside the structures; acceleration of each structure; deflection of each structure; dust inside each structure; fragmentary missiles inside the concrete structures; and gamma and neutron radiation dose inside each structure. All buried conduit sections tested provided adequate Class I protection for the conditions under which the conduits were tested. Standard 8-foot concrete sewer pipe withstood 126-psi overpressure without significant damage, minor tension cracks observed; standard 10-gage corrugated-steel 8-foot circular conduit sections withstood 126- psi overpressure without significant damage; and standard 10-gage corrugated- steel cattle-pass conduits withstood 149-psi overpressure without significant damage. Durations of positive pressure were from 206 to 333 milliseconds. (auth)« less

  2. Design of barrier coatings on kink-resistant peripheral nerve conduits

    PubMed Central

    Clements, Basak Acan; Bushman, Jared; Murthy, N Sanjeeva; Ezra, Mindy; Pastore, Christopher M; Kohn, Joachim

    2016-01-01

    Here, we report on the design of braided peripheral nerve conduits with barrier coatings. Braiding of extruded polymer fibers generates nerve conduits with excellent mechanical properties, high flexibility, and significant kink-resistance. However, braiding also results in variable levels of porosity in the conduit wall, which can lead to the infiltration of fibrous tissue into the interior of the conduit. This problem can be controlled by the application of secondary barrier coatings. Using a critical size defect in a rat sciatic nerve model, the importance of controlling the porosity of the nerve conduit walls was explored. Braided conduits without barrier coatings allowed cellular infiltration that limited nerve recovery. Several types of secondary barrier coatings were tested in animal studies, including (1) electrospinning a layer of polymer fibers onto the surface of the conduit and (2) coating the conduit with a cross-linked hyaluronic acid-based hydrogel. Sixteen weeks after implantation, hyaluronic acid-coated conduits had higher axonal density, displayed higher muscle weight, and better electrophysiological signal recovery than uncoated conduits or conduits having an electrospun layer of polymer fibers. This study indicates that braiding is a promising method of fabrication to improve the mechanical properties of peripheral nerve conduits and demonstrates the need to control the porosity of the conduit wall to optimize functional nerve recovery. PMID:26977288

  3. Delayed xenograft rejection.

    PubMed

    Hancock, W W

    1997-01-01

    The triumph of genetic engineering in overcoming hyperacute rejection (HAR) of a discordant organ xenograft is clear, but the promise of clinical application of xenotransplantation remains unfulfilled as further immunologic barriers are defined that lead to rejection of a vascularized xenograft within days of transplantation. This report describes the features of this second set of immunologic responses, collectively termed delayed xenograft rejection (DXR). DXR is a syndrome seen in xenograft recipients in which HAR has been avoided or suppressed by antibody depletion or blockade of complement activation. DXR may result, at least in part, from the persisting activation of those pathways first encountered during the HAR phase. Serial studies over several days after transplant show that, histologically, xenografts undergoing DXR demonstrate varying combinations of (1) progressive infiltration by activated macrophages and natural killer (NK) cells, (2) platelet aggregation and fibrin deposition throughout the microvasculature, and (3) endothelial activation. In various experimental models, DXR is T cell-independent and can occur in the absence of demonstrable xenoreactive antibodies. Hence DXR is probably best regarded as arising from the activation of innate host defense mechanisms coupled with failure of normal regulatory mechanisms due to manifold molecular incompatibilities. Although DXR-like features can be seen in concordant models, T cell involvement in the latter is probably requisite. Similarly, in a much muted form, aspects of a DXR-like process may contribute to numerous inflammatory processes, including allograft rejection. The importance of DXR in xenotransplantation is that its development appears resistant to all but the most dense and toxic forms of immunosuppression, which prolong xenograft survival at the expense of inducing host leukopenia, thrombocytopenia, and coagulopathies. It is likely that until the basis of DXR is more clearly understood

  4. 47 CFR 32.2441 - Conduit systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  5. 47 CFR 32.2441 - Conduit systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 2 2014-10-01 2014-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  6. 47 CFR 32.2441 - Conduit systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  7. 47 CFR 32.2441 - Conduit systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 2 2012-10-01 2012-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  8. 47 CFR 32.2441 - Conduit systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Conduit systems. 32.2441 Section 32.2441 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES Instructions for Balance Sheet Accounts § 32.2441 Conduit systems. (a...

  9. Aortic cusp extension for surgical correction of rheumatic aortic valve insufficiency in children.

    PubMed

    Kalangos, Afksendiyos; Myers, Patrick O

    2013-10-01

    Surgical management of aortic insufficiency in the young is problematic because of the lack of an ideal valve substitute. Potential advantages of aortic valve repair include low incidences of thromboembolism and endocarditis, avoiding conduit replacements, the maintenance of growth potential, and improved quality of life. Aortic valve repair is still far from fulfilling the three key factors that have allowed the phenomenal development of mitral valve repair (standardization, reproducibility, and stable long-term results); however, techniques of aortic valve repair have been refined, and subsets of patients amenable to repair have been identified. We have focused on the oldest technique of aortic valve repair, cusp extension, focusing on children with rheumatic aortic insufficiency. Among 77 children operated from 2003 to 2007, there was one early death from ventricular failure and one late death from sudden cardiac arrhythmia. During a mean follow-up of 12.8 ± 5.9 years, there were 16 (20.5%) reoperations on the aortic valve, at a median of 3.4 years (range, 2 months to 18.3 years) from repair. Freedom from aortic valve reoperation was 96.2% ± 2.2% at 1 year, 94.9% ± 2.5% at 2 years, 88.5% ± 3.6% at 5 years, 81.7% ± 4.4% at 10 years, 79.7% ± 4.8% at 15 years, and 76.2% ± 5.7% at 20 years. Although aortic cusp extension is technically more demanding, it remains particularly more suitable in the context of evolving rheumatic aortic insufficiency in children with a small aortic annulus as a bridge surgical approach to late aortic valve replacement with a larger valvular prosthesis.

  10. In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart Valve

    PubMed Central

    Claiborne, Thomas E.; Sheriff, Jawaad; Kuetting, Maximilian; Steinseifer, Ulrich; Slepian, Marvin J.; Bluestein, Danny

    2013-01-01

    Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the

  11. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall be...

  12. Decellularized fresh homografts for pulmonary valve replacement: a decade of clinical experience†

    PubMed Central

    Sarikouch, Samir; Horke, Alexander; Tudorache, Igor; Beerbaum, Philipp; Westhoff-Bleck, Mechthild; Boethig, Dietmar; Repin, Oleg; Maniuc, Liviu; Ciubotaru, Anatol; Haverich, Axel; Cebotari, Serghei

    2016-01-01

    OBJECTIVES Decellularized homografts have shown auspicious early results when used for pulmonary valve replacement (PVR) in congenital heart disease. The first clinical application in children was performed in 2002, initially using pre-seeding with endogenous progenitor cells. Since 2005, only non-seeded, fresh decellularized allografts have been implanted after spontaneous recellularization was observed by several groups. METHODS A matched comparison of decellularized fresh pulmonary homografts (DPHs) implanted for PVR with cryopreserved pulmonary homografts (CHs) and bovine jugular vein conduits (BJVs) was conducted. Patients’ age at implantation, the type of congenital malformation, number of previous cardiac operations and number of previous PVRs were considered for matching purposes, using an updated contemporary registry of right ventricular outflow tract conduits (2300 included conduits, >12 000 patient-years). RESULTS A total of 131 DPHs were implanted for PVR in the period from January 2005 to September 2015. Of the 131, 38 were implanted within prospective trials on DPH from October 2014 onwards and were therefore not analysed within this study. A total of 93 DPH patients (58 males, 35 females) formed the study cohort and were matched to 93 CH and 93 BJV patients. The mean age at DPH implantation was 15.8 ± 10.21 years (CH 15.9 ± 10.4, BJV 15.6 ± 9.9) and the mean DPH diameter was 23.9 mm (CH 23.3 ± 3.6, BJV 19.9 ± 2.9). There was 100% follow-up for DPH, including 905 examinations with a mean follow-up of 4.59 ± 2.76 years (CH 7.4 ± 5.8, BJV 6.4 ± 3.8), amounting to 427.27 patient-years in total (CH 678.3, BJV 553.0). Tetralogy-of-Fallot was the most frequent malformation (DPH 50.5%, CH 54.8%, BJV 68.8%). At 10 years, the rate of freedom of explantation was 100% for DPH, 84.2% for CH (P = 0.01) and 84.3% for BJV (P= 0.01); the rate of freedom from explantation and peak trans-conduit gradient ≥50 mmHg was 86% for DPH, 64% for CH (n.s.) and 49

  13. Tetralogy of Fallot with absent pulmonary valve syndrome; appropriate surgical strategies.

    PubMed

    Shahid, Fatima; Siddiqui, Maria Tariq; Amanullah, Muhammad Muneer

    2015-05-01

    To evaluate patients presenting with Tetralogy of Fallot with absent pulmonary valve syndrome to a tertiary care hospital and their surgical management. The retrospective study was conducted at Congenital Cardiac Services, Aga Khan University Hospital, Karachi, Pakistan, and comprised data of Tetralogy of Fallot patients between April 2007 and June 2012. Data was analysed together with follow-up echocardiography. Variables assessed included demographics, imaging, operative technique, complications, post-operative recovery and follow-up echocardiography. SPSS 17 was used for statistical analysis. Of the 204 patients, 6 (3%) had undergone surgical correction for Tetralogy of Fallot with absent pulmonary valve syndrome. All 6(100%) patients underwent complete repair. Median age for surgery was 8.5 years (range: 0.5-29 years). Of the different surgical strategies used, Contegra and Bioprosthetic valve placement had satisfactory outcome with minimal gradient at Right Ventricular Outflow Tract, good ventricular function and mild valvular regurgitation. One (16.6%) patient with Trans Annular Patch developed post-operative Right Ventricle Outflow Tract gradient of 80mmHg with moderate pulmonary regurgitation. One (16.6%) patient with monocusp valve developed free pulmonary regurgitation at 6 months. The other 4(66.6%) patients are currently free from any complications or re-intervention. Early surgery is preferred in symptomatic patients. The repair depends upon achieving integrity of pulmonary circulation which is best achieved by using right ventricle to pulmonary artery conduit or inserting a pulmonary valve.

  14. Coronary reconnection in emergency "conduit operation" for acute type-a aortic dissection with aortic insufficiency: experience with 24 cases.

    PubMed

    Massimo, C G; Presenti, L F; Favi, P P; Duranti, A; Poma, A G; Marranci, P; Modiano, C

    1987-12-01

    Twenty-four cases of acute type-A aortic dissection with aortic valvular insufficiency were treated in our institution by means of an emergency operation in which the aortic valve, ascending aorta, and aortic arch were resected and replaced with a valved conduit that had been lengthened with a tubular Dacron graft. The procedure included the use of deep hypothermia for cerebral protection, as well as extracorporeal circulation. Aortic resection was performed from the aortic valve to the origin of the descending thoracic aorta; the aortic graft was anastomosed proximally to the valve annulus and distally to the descending aorta. The carotid orifices were connected to the side of the graft in a single tissue button. The coronary arteries were then reconnected by means of double venous bypass grafts to the innominate artery, to allow for inclusion of the graft. Within 1 month after operation, four patients died of the consequences of dissection. Six months postoperatively, one patient succumbed to an infarction. Six months to 5 years after operation, the remaining 19 patients are still alive. On the basis of this experience, we believe that acute type-A aortic dissection with aortic valvular insufficiency should be treated during the first hours after the onset of symptoms. The above-described procedure proved effective in the control of bleeding, which is the major risk in emergency operations of this type.

  15. System and method measuring fluid flow in a conduit

    DOEpatents

    Ortiz, Marcos German; Kidd, Terrel G.

    1999-01-01

    A system for measuring fluid mass flow in a conduit in which there exists a pressure differential in the fluid between at least two spaced-apart locations in the conduit. The system includes a first pressure transducer disposed in the side of the conduit at a first location for measuring pressure of fluid at that location, a second or more pressure transducers disposed in the side of the conduit at a second location, for making multiple measurements of pressure of fluid in the conduit at that location, and a computer for computing the average pressure of the multiple measurements at the second location and for computing flow rate of fluid in the conduit from the pressure measurement by the first pressure transducer and from the average pressure calculation of the multiple measurements.

  16. Flexible cryogenic conduit

    DOEpatents

    Brindza, Paul Daniel; Wines, Robin Renee; Takacs, James Joseph

    1999-01-01

    A flexible and relatively low cost cryogenic conduit is described. The flexible cryogenic conduit of the present invention comprises a first inner corrugated tube with single braided serving, a second outer corrugated tube with single braided serving concentric with the inner corrugated tube, and arranged outwardly about the periphery of the inner corrugated tube and between the inner and outer corrugated tubes: a superinsulation layer; a one half lap layer of polyester ribbon; a one half lap layer of copper ribbon; a spirally wound refrigeration tube; a second one half lap layer of copper ribbon; a second one half lap layer of polyester ribbon; a second superinsulation layer; a third one half lap layer of polyester ribbon; and a spirally wound stretchable and compressible filament.

  17. Source model of volcanic tremor: two-phase flow instability in a pipe-valve system

    NASA Astrophysics Data System (ADS)

    Fujita, E.

    2003-12-01

    Volcanic tremor at a shallow depth beneath the volcano is inferred to link to hydrothermal activities powered by heat supply from magma. In this study, we developed numerical simulations of the instabilities of the water-steam two-phase flow in a pipe-valve system and considered the source mechanism of volcanic tremor. The experiments of two-phase flow by Veziroglu and Lee [1968] revealed the two kinds of oscillating modes, density wave oscillation with the period of a few seconds and pressure drop oscillation with the period of dozens of seconds. These modes were mainly controlled by the pressure difference between inlet and outlet, flux rate of fluid and heat supply rate. Especially, the former mode appears when the flux rate is small and the latter does when the pressure difference and heat supply rate are larger. We performed some preliminary numerical simulation of these oscillations in water-steam flow in a cylindrical conduit. As an example, we assume the flow in conduit of 4 m length with the valves at inlet and outlet with the conditions of non-slip at the wall. As initial conditions, the inlet and outlet pressures are fixed to be 1.2E5 Pa and 1.0E5 Pa, respectively, water temperature of 370 K, heat supply of 1.0E6 - 2.0E7W/m3. The friction except the valve area is assumed to be 1000kg/m3. After the heating condition becomes stable, we shut the valve at the outlet and detect the significant oscillation. In case of the heat supply of 1.1E7W/m3, density drop oscillation with the period of 0.16s has appeared. In this model, the oscillation originates from the density change due to vaporization, and its information arrives at the outlet with the velocity of two-phase flow. The cycle of heating and boiling controls the interval of the tremor occurrence and the period is determined by the length of the pipe and the flow velocity. The shut of valve physically corresponds to geometrical narrowing, choking, and non-linear effect of flow and/or surrounding medium.

  18. System and method measuring fluid flow in a conduit

    DOEpatents

    Ortiz, M.G.; Kidd, T.G.

    1999-05-18

    A system is described for measuring fluid mass flow in a conduit in which there exists a pressure differential in the fluid between at least two spaced-apart locations in the conduit. The system includes a first pressure transducer disposed in the side of the conduit at a first location for measuring pressure of fluid at that location, a second or more pressure transducers disposed in the side of the conduit at a second location, for making multiple measurements of pressure of fluid in the conduit at that location, and a computer for computing the average pressure of the multiple measurements at the second location and for computing flow rate of fluid in the conduit from the pressure measurement by the first pressure transducer and from the average pressure calculation of the multiple measurements. 3 figs.

  19. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Elastin Shapes Small Molecule Distribution in Lymph Node Conduits.

    PubMed

    Lin, Yujia; Louie, Dante; Ganguly, Anutosh; Wu, Dequan; Huang, Peng; Liao, Shan

    2018-05-01

    The spatial and temporal Ag distribution determines the subsequent T cell and B cell activation at the distinct anatomical locations in the lymph node (LN). It is well known that LN conduits facilitate small Ag distribution in the LN, but the mechanism of how Ags travel along LN conduits remains poorly understood. In C57BL/6J mice, using FITC as a fluorescent tracer to study lymph distribution in the LN, we found that FITC preferentially colocalized with LN capsule-associated (LNC) conduits. Images generated using a transmission electron microscope showed that LNC conduits are composed of solid collagen fibers and are wrapped with fibroblastic cells. Superresolution images revealed that high-intensity FITC is typically colocalized with elastin fibers inside the LNC conduits. Whereas tetramethylrhodamine isothiocyanate appears to enter LNC conduits as effectively as FITC, fluorescently-labeled Alexa-555-conjugated OVA labels significantly fewer LNC conduits. Importantly, injection of Alexa-555-conjugated OVA with LPS substantially increases OVA distribution along elastin fibers in LNC conduits, indicating immune stimulation is required for effective OVA traveling along elastin in LN conduits. Finally, elastin fibers preferentially surround lymphatic vessels in the skin and likely guide fluid flow to the lymphatic vessels. Our studies demonstrate that fluid or small molecules are preferentially colocalized with elastin fibers. Although the exact mechanism of how elastin fibers regulate Ag trafficking remains to be explored, our results suggest that elastin can be a potentially new target to direct Ag distribution in the LN during vaccine design. Copyright © 2018 by The American Association of Immunologists, Inc.

  1. Engineering Bi-Layer Nanofibrous Conduits for Peripheral Nerve Regeneration

    PubMed Central

    Zhu, Yiqian; Wang, Aijun; Patel, Shyam; Kurpinski, Kyle; Diao, Edward; Bao, Xuan; Kwong, George; Young, William L.

    2011-01-01

    Trauma injuries often cause peripheral nerve damage and disability. A goal in neural tissue engineering is to develop synthetic nerve conduits for peripheral nerve regeneration having therapeutic efficacy comparable to that of autografts. Nanofibrous conduits with aligned nanofibers have been shown to promote nerve regeneration, but current fabrication methods rely on rolling a fibrous sheet into the shape of a conduit, which results in a graft with inconsistent size and a discontinuous joint or seam. In addition, the long-term effects of nanofibrous nerve conduits, in comparison with autografts, are still unknown. Here we developed a novel one-step electrospinning process and, for the first time, fabricated a seamless bi-layer nanofibrous nerve conduit: the luminal layer having longitudinally aligned nanofibers to promote nerve regeneration, and the outer layer having randomly organized nanofibers for mechanical support. Long-term in vivo studies demonstrated that bi-layer aligned nanofibrous nerve conduits were superior to random nanofibrous conduits and had comparable therapeutic effects to autografts for nerve regeneration. In summary, we showed that the engineered nanostructure had a significant impact on neural tissue regeneration in situ. The results from this study will also lead to the scalable fabrication of engineered nanofibrous nerve conduits with designed nanostructure. This technology platform can be combined with drug delivery and cell therapies for tissue engineering. PMID:21501089

  2. Using TLS to Improve Models of Volcano Conduit Processes (Invited)

    NASA Astrophysics Data System (ADS)

    Connor, C.; Connor, L.

    2010-12-01

    In volcanology, diverse numerical models of conduit flow have been developed to relate the properties of these flows to processes that occur at the surface during eruptions. Conduit models incorporate varying degrees of complexity and account for the transport properties of magmas, steady-state or transient behavior, and conduit geometry (e.g., 1- to 1.5 D, variable width and erodable conduit walls). Improvement of these models is important if we are to work toward deployment of eruption models at active volcanoes, link these models to geophysical observations (seismic, deformation, gravity) and eventually forecast eruption magnitude. One conclusion of a recent comparison of many conduit models is that next generation models need to better account for interaction of the erupting mixture with surrounding wall rocks (accounting for melting, solidification, and erosion) and better account for the effects of conduit shape on flows. We made progress toward accounting for this interaction by using TLS to map basaltic conduits in a deeply eroded volcanic field, the San Rafael volcanic field, Utah. TLS data were collected with UNAVCO support during a field campaign in summer 2010. A region of approximately 1 x 1 km was imaged from 9 TLS stations. TLS data reveal the exact geometries of several exposed conduits, their relationship to sills and dikes, and dramatic change in reflectivity of the Entrada sandstone country rock with alteration. The TLS data are particularly good for (a) quantifying rapid change in conduit shape and area as a function of height, (b) differentiating breccias zones (complex mixing zones along conduit margins) from areas of late stage intrusion, (c) imaging complexity of sill geometry near conduits, illustrating the mechanical and perhaps geochemical interaction between sills and conduits in volcanic fields. Overall, application of TLS in this volcanic field has resulted in substantial improvement in our models of volcanic conduit formation, growth

  3. Orthotopic Patient-Derived Glioblastoma Xenografts in Mice.

    PubMed

    Xu, Zhongye; Kader, Michael; Sen, Rajeev; Placantonakis, Dimitris G

    2018-01-01

    Patient-derived xenografts (PDX) provide in vivo glioblastoma (GBM) models that recapitulate actual tumors. Orthotopic tumor xenografts within the mouse brain are obtained by injection of GBM stem-like cells derived from fresh surgical specimens. These xenografts reproduce GBM's histologic complexity and hallmark biological behaviors, such as brain invasion, angiogenesis, and resistance to therapy. This method has become essential for analyzing mechanisms of tumorigenesis and testing the therapeutic effect of candidate agents in the preclinical setting. Here, we describe a protocol for establishing orthotopic tumor xenografts in the mouse brain with human GBM cells.

  4. Conduit stability effects on intensity and steadiness of explosive eruptions.

    PubMed

    Aravena, Álvaro; Cioni, Raffaello; de'Michieli Vitturi, Mattia; Neri, Augusto

    2018-03-07

    Conduit geometry affects magma ascent dynamics and, consequently, the style and evolution of volcanic eruptions. However, despite geological evidences support the occurrence of conduit widening during most volcanic eruptions, the factors controlling conduit enlargement are still unclear, and the effects of syn-eruptive variations of conduit geometry have not been investigated in depth yet. Based on numerical modeling and the application of appropriate stability criteria, we found out a strong relationship between magma rheology and conduit stability, with significant effects on eruptive dynamics. Indeed, in order to be stable, conduits feeding dacitic/rhyolitic eruptions need larger diameters respect to their phonolitic/trachytic counterparts, resulting in the higher eruption rates commonly observed in dacitic/rhyolitic explosive events. Thus, in addition to magma source conditions and viscosity-dependent efficiency for outgassing, we suggest that typical eruption rates for different magma types are also controlled by conduit stability. Results are consistent with a compilation of volcanological data and selected case studies. As stability conditions are not uniform along the conduit, widening is expected to vary in depth, and three axisymmetric geometries with depth-dependent radii were investigated. They are able to produce major modifications in eruptive parameters, suggesting that eruptive dynamics is influenced by syn-eruptive changes in conduit geometry.

  5. Retained structural integrity of collagen and elastin within cryopreserved human heart valve tissue as detected by two-photon laser scanning confocal microscopy.

    PubMed

    Gerson, Cindy J; Goldstein, Steven; Heacox, Albert E

    2009-10-01

    Cryopreservation is commonly used for the long-term storage of heart valve allografts. Despite the excellent hemodynamic performance and durability of cryopreserved allografts, reports have questioned whether cryopreservation affects the valvular structural proteins, collagen and elastin. This study uses two-photon laser scanning confocal microscopy (LSCM) to evaluate the effect of cryopreservation on collagen and elastin integrity within the leaflet and conduit of aortic and pulmonary human heart valves. To permit pairwise comparisons of fresh and cryopreserved tissue, test valves were bisected longitudinally with one segment imaged fresh and the other imaged after cryopreservation and brief storage in liquid nitrogen. Collagen was detected by second harmonic generation (SHG) stimulation and elastin by autofluorescence excitation. Qualitative analysis of all resultant images indicated the maintenance of collagen and elastin structure within leaflet and conduit post-cryopreservation. Analysis of the optimized percent laser transmission (OPLT) required for full dynamic range imaging of collagen and elastin showed that OPLT observations were highly variable among both fresh and cryopreserved samples. Changes in donor-specific average OPLT in response to cryopreservation exhibited no consistent directional trend. The donor-aggregated results predominantly showed no statistically significant change in collagen and elastin average OPLT due to cryopreservation. Since OPLT has an inverse relationship with structural signal intensity, these results indicate that there was largely no statistical difference in collagen and elastin signal strength between fresh and cryopreserved tissue. Overall, this study indicates that the conventional cryopreservation of human heart valve allografts does not detrimentally affect their collagen and elastin structural integrity.

  6. Systems for delivering liquified natural gas to an engine

    DOEpatents

    Bingham, Dennis N.; Wilding, Bruce M.; O'Brien, James E.; Siahpush, Ali S.; Brown, Kevin B.

    2000-01-01

    A fuel delivery system includes a fuel tank configured to receive liquid natural gas. A first conduit extends from a vapor holding portion of the fuel tank to an economizer valve. A second conduit extends from a liquid holding portion of the fuel tank to the economizer valve. Fluid coupled to the economizer valve is a vaporizer which is heated by coolant from the engine and is positioned below the fuel tank. The economizer valve selectively withdraws either liquid natural gas or vaporized natural gas from the fuel tank depending on the pressure within the vapor holding portion of the fuel tank. A delivery conduit extends from the vaporizer to the engine. A return conduit having a check valve formed therein extends from the delivery conduit to the vapor holding portion of the fuel tank for pressurizing the fuel tank.

  7. Explosive actuated valve

    DOEpatents

    Byrne, Kenneth G.

    1983-01-01

    1. A device of the character described comprising the combination of a housing having an elongate bore and including a shoulder extending inwardly into said bore, a single elongate movable plunger disposed in said bore including an outwardly extending flange adjacent one end thereof overlying said shoulder, normally open conduit means having an inlet and an outlet perpendicularly piercing said housing intermediate said shoulder and said flange and including an intermediate portion intersecting and normally openly communicating with said bore at said shoulder, normally closed conduit means piercing said housing and intersecting said bore at a location spaced from said normally open conduit means, said elongate plunger including a shearing edge adjacent the other end thereof normally disposed intermediate both of said conduit means and overlying a portion of said normally closed conduit means, a deformable member carried by said plunger intermediate said flange and said shoulder and normally spaced from and overlying the intermediate portion of said normally open conduit means, and means on the housing communicating with the bore to retain an explosive actuator for moving said plunger to force the deformable member against the shoulder and extrude a portion of the deformable member out of said bore into portions of the normally open conduit means for plugging the same and to effect the opening of said normally closed conduit means by the plunger shearing edge substantially concomitantly with the plugging of the normally open conduit means.

  8. Water Flow in Karst Aquifer Considering Dynamically Variable Saturation Conduit

    NASA Astrophysics Data System (ADS)

    Tan, Chaoqun; Hu, Bill X.

    2017-04-01

    The karst system is generally conceptualized as dual-porosity system, which is characterized by low conductivity and high storage continuum matrix and high conductivity and quick flow conduit networks. And so far, a common numerical model for simulating flow in karst aquifer is MODFLOW2005-CFP, which is released by USGS in 2008. However, the steady-state approach for conduit flow in CFP is physically impractical when simulating very dynamic hydraulics with variable saturation conduit. So, we adopt the method proposed by Reimann et al. (2011) to improve current model, in which Saint-Venant equations are used to model the flow in conduit. Considering the actual background that the conduit is very big and varies along flow path and the Dirichlet boundary varies with rainfall in our study area in Southwest China, we further investigate the influence of conduit diameter and outflow boundary on numerical model. And we also analyze the hydraulic process in multi-precipitation events. We find that the numerical model here corresponds well with CFP for saturated conduit, and it could depict the interaction between matrix and conduit during very dynamic hydraulics pretty well compare with CFP.

  9. 3D-engineering of Cellularized Conduits for Peripheral Nerve Regeneration

    NASA Astrophysics Data System (ADS)

    Hu, Yu; Wu, Yao; Gou, Zhiyuan; Tao, Jie; Zhang, Jiumeng; Liu, Qianqi; Kang, Tianyi; Jiang, Shu; Huang, Siqing; He, Jiankang; Chen, Shaochen; Du, Yanan; Gou, Maling

    2016-08-01

    Tissue engineered conduits have great promise for bridging peripheral nerve defects by providing physical guiding and biological cues. A flexible method for integrating support cells into a conduit with desired architectures is wanted. Here, a 3D-printing technology is adopted to prepare a bio-conduit with designer structures for peripheral nerve regeneration. This bio-conduit is consisted of a cryopolymerized gelatin methacryloyl (cryoGelMA) gel cellularized with adipose-derived stem cells (ASCs). By modeling using 3D-printed “lock and key” moulds, the cryoGelMA gel is structured into conduits with different geometries, such as the designed multichannel or bifurcating and the personalized structures. The cryoGelMA conduit is degradable and could be completely degraded in 2-4 months in vivo. The cryoGelMA scaffold supports the attachment, proliferation and survival of the seeded ASCs, and up-regulates the expression of their neurotrophic factors mRNA in vitro. After implanted in a rat model, the bio-conduit is capable of supporting the re-innervation across a 10 mm sciatic nerve gap, with results close to that of the autografts in terms of functional and histological assessments. The study describes an indirect 3D-printing technology for fabricating cellularized designer conduits for peripheral nerve regeneration, and could lead to the development of future nerve bio-conduits for clinical use.

  10. Are homografts superior to conventional prosthetic valves in the setting of infective endocarditis involving the aortic valve?

    PubMed

    Kim, Joon Bum; Ejiofor, Julius I; Yammine, Maroun; Camuso, Janice M; Walsh, Conor W; Ando, Masahiko; Melnitchouk, Serguei I; Rawn, James D; Leacche, Marzia; MacGillivray, Thomas E; Cohn, Lawrence H; Byrne, John G; Sundt, Thoralf M

    2016-05-01

    Surgical dogma suggests that homografts should be used preferentially, compared with conventional xenograft or mechanical prostheses, in the setting of infective endocarditis (IE), because they have greater resistance to infection. However, comparative data that support this notion are limited. From the prospective databases of 2 tertiary academic centers, we identified 304 consecutive adult patients (age ≥17 years) who underwent surgery for active IE involving the aortic valve (AV), in the period 2002 to 2014. Short- and long-term outcomes were evaluated using propensity scores and inverse-probability weighting to adjust for selection bias. Homografts, and xenograft and mechanical prostheses, were used in 86 (28.3%), 139 (45.7%), and 79 (26.0%) patients, respectively. Homografts were more often used in the setting of prosthetic valve endocarditis (58.1% vs 28.8%, P = .002) and methicillin-resistant Staphylococcus (25.6% vs 12.1%, P = .002), compared with conventional prostheses. Early mortality occurred in 17 (19.8%) in the homograft group, and 20 (9.2%) in the conventional group (P = .019). During follow-up (median: 29.4 months; interquartile-range: 4.7-72.6 months), 60 (19.7%) patients died, and 23 (7.7%) experienced reinfection, with no significant differences in survival (P = .23) or freedom from reinfection rates (P = .65) according to the types of prostheses implanted. After adjustments for baseline characteristics, using propensity-score analyses, use of a homograft did not significantly affect early death (odds ratio 1.61; 95% confidence interval [CI], 0.73-3.40, P = .23), overall death (hazard ratio 1.10; 95% CI, 0.62-1.94, P = .75), or reinfection (hazard ratio 1.04; 95% CI, 0.49-2.18, P = .93). No significant benefit to use of homografts was demonstrable with regard to resistance to reinfection in the setting of IE. The choice among prosthetic options should be based on technical and patient-specific factors. Lack of availability of homografts should

  11. Temperature limited heater with a conduit substantially electrically isolated from the formation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vinegar, Harold J; Sandberg, Chester Ledlie

    2009-07-14

    A system for heating a hydrocarbon containing formation is described. A conduit may be located in an opening in the formation. The conduit includes ferromagnetic material. An electrical conductor is positioned inside the conduit, and is electrically coupled to the conduit at or near an end portion of the conduit so that the electrical conductor and the conduit are electrically coupled in series. Electrical current flows in the electrical conductor in a substantially opposite direction to electrical current flow in the conduit during application of electrical current to the system. The flow of electrons is substantially confined to the insidemore » of the conduit by the electromagnetic field generated from electrical current flow in the electrical conductor so that the outside surface of the conduit is at or near substantially zero potential at 25.degree. C. The conduit may generate heat and heat the formation during application of electrical current.« less

  12. Thermomechanical milling of accessory lithics in volcanic conduits

    NASA Astrophysics Data System (ADS)

    Campbell, Michelle E.; Russell, James K.; Porritt, Lucy A.

    2013-09-01

    Accessory lithic clasts recovered from pyroclastic deposits commonly result from the failure of conduit wall rocks, and represent an underutilized resource for constraining conduit processes during explosive volcanic eruptions. The morphological features of lithic clasts provide distinctive 'textural fingerprints' of processes that have reshaped them during transport in the conduit. Here, we present the first study focused on accessory lithic clast morphology and show how the shapes and surfaces of these accessory pyroclasts can inform on conduit processes. We use two main types of accessory lithic clasts from pyroclastic fallout deposits of the 2360 B.P. subplinian eruption of Mount Meager, British Columbia, as a case study: (i) rough and subangular dacite clasts, and (ii) variably rounded and smoothed monzogranite clasts. The quantitative morphological data collected on these lithics include: mass, volume, density, 2-D image analysis of convexity (C), and 3-D laser scans for sphericity (Ψ) and smoothness (S). Shaping and comminution (i.e. milling) of clasts within the conduit are ascribed to three processes: (1) disruptive fragmentation due to high-energy impacts between clasts or between clasts and conduit walls, (2) ash-blasting of clasts suspended within the volcanic flux, and (3) thermal effects. We use a simplified conduit eruption model to predict ash-blasting velocities and lithic residence times as a function of clast size and source depth, thereby constraining the lithic milling processes. The extent of shape and surface modification (i.e. rounding and honing) is directly proportional to clast residence times within the conduit prior to evacuation. We postulate that the shallow-seated dacite clasts remain subangular and rough due to short (<2 min) residence times, whereas monzogranite clasts are much more rounded and smoothed due to deeper source depths and consequently longer residence times (up to ˜1 h). Larger monzogranite clasts are smoother than

  13. A novel conduit-based coaptation device for primary nerve repair.

    PubMed

    Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P

    2018-06-01

    Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.

  14. A 3D-engineered porous conduit for peripheral nerve repair

    PubMed Central

    Tao, Jie; Hu, Yu; Wang, Shujuan; Zhang, Jiumeng; Liu, Xuan; Gou, Zhiyuan; Cheng, Hao; Liu, Qianqi; Zhang, Qianqian; You, Shenglan; Gou, Maling

    2017-01-01

    End-to-end neurorrhaphy is the most commonly used method for treating peripheral nerve injury. However, only 50% of patients can regain useful function after treating with neurorrhaphy. Here, we constructed a 3D-engineered porous conduit to promote the function recovery of the transected peripheral nerve after neurorrhaphy. The conduit that consisted of a gelatin cryogel was prepared by molding with 3D-printed moulds. Due to its porous structure and excellent mechanical properties, this conduit could be collapsed by the mechanical force and resumed its original shape after absorption of normal saline. This shape-memory property allowed a simply surgery process for installing the conduits. Moreover, the biodegradable conduit could prevent the infiltration of fibroblasts and reduce the risk of scar tissue, which could provide an advantageous environment for nerve regeneration. The efficiency of the conduits in assisting peripheral nerve regeneration after neurorrhaphy was evaluated in a rat sciatic nerve transected model. Results indicated that conduits significantly benefitted the recovery of the transected peripheral nerve after end-to-end neurorrhaphy on the static sciatic index (SSI), electrophysiological results and the re-innervation of the gastrocnemius muscle. This work demonstrates a biodegradable nerve conduit that has potentially clinical application in promoting the neurorrhaphy. PMID:28401914

  15. [Osteostimulating effect of bone xenograft on bone tissue regeneration].

    PubMed

    Balin, V N; Balin, D V; Iordanishvili, A K; Musikin, M I

    2015-01-01

    The aim of experimental case-control study performed in 28 dogs divided in 2 groups was to assess local tissue reactions on bone xenograft transplantation; dynamics of bone remodeling and formation at the site of bone defect wall contacting with bone xenograft; dynamics and mechanisms of xenograft remodeling. Transplantation of xenograft in conventional bone defects did not cause inflammatory of destructive reactions because of high biocompatibility of the material. At transplantation site active fibrous bone trabeculae formation filling the spaces between xenograft participles was observed. On the 90th day newly formed bone showed lammelar structure. Simultaneously from the 42d day the invasion of cell elements from recipient bed into the material was seen leading to xenograft resorption. The observed dynamics may be assessed as gradual substitution of xenograft with newly formed host bone structures.

  16. 18 CFR 358.6 - No conduit rule.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false No conduit rule. 358.6 Section 358.6 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY STANDARDS OF CONDUCT FOR TRANSMISSION PROVIDERS STANDARDS OF CONDUCT § 358.6 No conduit...

  17. Conduits and dike distribution analysis in San Rafael Swell, Utah

    NASA Astrophysics Data System (ADS)

    Kiyosugi, K.; Connor, C.; Wetmore, P. H.; Ferwerda, B. P.; Germa, A.

    2011-12-01

    Volcanic fields generally consist of scattered monogenetic volcanoes, such as cinder cones and maars. The temporal and spatial distribution of monogenetic volcanoes and probability of future activity within volcanic fields is studied with the goals of understanding the origins of these volcano groups, and forecasting potential future volcanic hazards. The subsurface magmatic plumbing systems associated with volcanic fields, however, are rarely observed or studied. Therefore, we investigated a highly eroded and exposed magmatic plumbing system on the San Rafael Swell (UT) that consists of dikes, volcano conduits and sills. San Rafael Swell is part of the Colorado Plateau and is located east of the Rocky Mountain seismic belt and the Basin and Range. The overburden thickness at the time of mafic magma intrusion (Pliocene; ca. 4 Ma) into Jurassic sandstone is estimated to be ~800 m based on paleotopographical reconstructions. Based on a geologic map by P. Delaney and colleagues, and new field research, a total of 63 conduits are mapped in this former volcanic field. The conduits each reveal features of root zone and / or lower diatremes, including rapid dike expansion, peperite and brecciated intrusive and host rocks. Recrystallized baked zone of host rock is also observed around many conduits. Most conduits are basaltic or shonkinitic with thickness of >10 m and associated with feeder dikes intruded along N-S trend joints in the host rock, whereas two conduits are syenitic and suggesting development from underlying cognate sills. Conduit distribution, which is analyzed by a kernel function method with elliptical bandwidth, illustrates a N-S elongate higher conduit density area regardless of the azimuth of closely distributed conduits alignment (nearest neighbor distance <200 m). In addition, dike density was calculated as total dike length in unit area (km/km^2). Conduit and sill distribution is concordant with the high dike density area. Especially, the distribution

  18. Prosthetic valve sparing aortic root replacement: an improved technique.

    PubMed

    Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G

    2008-10-01

    We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.

  19. Tricuspid Regurgitation Does Not Impact Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    PubMed

    Tanase, Daniel; Ewert, Peter; Georgiev, Stanimir; Meierhofer, Christian; Pabst von Ohain, Jelena; McElhinney, Doff B; Hager, Alfred; Kühn, Andreas; Eicken, Andreas

    2017-04-10

    This study sought to investigate the impact of tricuspid regurgitation (TR) on right ventricular function after percutaneous pulmonary valve implantation (PPVI). PPVI provides a less invasive alternative to surgery in patients with right ventricular-to-pulmonary artery (RV-PA) conduit dysfunction. Recovery of the right ventricle has been described after PPVI for patients with pulmonary stenosis and for those with pulmonary regurgitation. Additional TR enforces RV dysfunction by supplemental volume overload. Limited data are available on the potential of the right ventricle to recover in such a specific hemodynamic situation. In a matched cohort study, we compared patients who underwent PPVI with additional TR with those without TR. The degree of TR improved in 83% of the patients. In our patients (n = 36) exercise capacity and right ventricular volume index improved similarly 6 months after PPVI in patients with and without important TR. None of them had significant TR in the long-term follow-up of median 78 months. PPVI improves not only RV-PA-conduit dysfunction, but also concomitant TR. In patients with a dysfunctional RV-PA conduit and TR, the decision whether to fix TR should be postponed after PPVI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Reconstruction of the right ventricular outflow tract with a bovine jugular vein graft fixed with a naturally occurring crosslinking agent (genipin) in a canine model.

    PubMed

    Chang, Y; Tsai, C C; Liang, H C; Sung, H W

    2001-12-01

    This study was designed to evaluate a newly developed biologic valved conduit fixed with genipin used to reconstruct the right ventricular outflow tract in a canine model. Fresh bovine jugular veins with a retained native valve procured from a slaughterhouse were used as raw materials to fabricate the valved conduits. A naturally occurring crosslinking agent, genipin, was used to fix the procured jugular veins. The glutaraldehyde-fixed counterpart was used as a control. A canine model was used in the study. Echocardiography revealed that the motion of the valvular leaflets in both the glutaraldehyde- and genipin-fixed conduits was satisfactory. The transvalvular pressure gradients of both studied groups were minimal. No endothelium-like cells were observed on the luminal surface of the conduit and the valvular leaflet for the glutaraldehyde-fixed group throughout the entire course of the study. In contrast, endothelium-like cells were observed on the entire surface of the genipin-fixed valved conduit retrieved at 6 months postoperatively in all the cases studied. There was no evidence of luminal fibrous peel in any the valved conduits studied. Degradation of valvular leaflet in one of the glutaraldehyde-fixed conduits was observed. In this particular case, thrombus formation was also observed on the surface of the valvular leaflet. On the other hand, no apparent degradation or thrombus formation was observed on the surfaces of the genipin-fixed valvular leaflet and conduit. A significantly more severe inflammatory reaction was observed for the glutaraldehyde-fixed conduit than for its genipin-fixed counterpart throughout the entire course of the study. The calcium contents of the samples before implantation and those retrieved at distinct implantation duration were minimal for both the glutaraldehyde- and genipin-fixed tissues. Although further studies are necessary, the genipin-fixed valved conduit appears to have great potential in helping mitigate the

  1. Innovative and effective techniques for locating underground conduits.

    DOT National Transportation Integrated Search

    2011-06-01

    The New Jersey Department of Transportation (NJDOT) operates and maintains a network of : thousands of miles of conduits, many carrying fiber optic cables, that is vital to the States : communication system. These conduits frequently must be locat...

  2. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  3. Experimental investigations of aeration efficiency in high-head gated circular conduits.

    PubMed

    Cihat Tuna, M; Ozkan, Fahri; Baylar, Ahmet

    2014-01-01

    The primary purpose of water aeration is to increase the oxygen saturation of the water. This can be achieved by using hydraulic structures because of substantial air bubble entrainment at these structures. Closed conduit aeration is a particular instance of this. While there has been a great deal of research on air-demand ratio within closed conduit, very little research has specifically addressed aeration efficiency of closed conduit. In the present work an experimental study was conducted to investigate the aeration efficiency of high-head gated circular conduits. Results showed that high-head gated circular conduits were effective for oxygen transfer. The effects of Froude number and ratio of the water cross-sectional flow area to the conduit cross-sectional area on aeration efficiency were particularly significant, whereas the effect of conduit length was only moderate. Further, a design formula for the aeration efficiency was presented relating the aeration efficiency to ratio of water cross-sectional flow area to conduit cross-sectional area and Froude number. The obtained results will be useful in future modeling processes and aid the practicing engineer in predicting aeration efficiency for design purposes.

  4. Consequences of intravascular lymphatic valve properties: a study of contraction timing in a multi-lymphangion model

    PubMed Central

    Macaskill, Charlie; Davis, Michael J.; Moore, James E.

    2016-01-01

    The observed properties of valves in collecting lymphatic vessels include transmural pressure-dependent bias to the open state and hysteresis. The bias may reduce resistance to flow when the vessel is functioning as a conduit. However, lymphatic pumping implies a streamwise increase in mean pressure across each valve, suggesting that the bias is then potentially unhelpful. Lymph pumping by a model of several collecting lymphatic vessel segments (lymphangions) in series, which incorporated these properties, was investigated under conditions of adverse pressure difference while varying the refractory period between active muscular contractions and the inter-lymphangion contraction delay. It was found that many combinations of the timing parameters and the adverse pressure difference led to one or more intermediate valves remaining open instead of switching between open and closed states during repetitive contraction cycles. Cyclic valve switching was reliably indicated if the mean pressure in a lymphangion over a cycle was higher than that in the lymphangion upstream, but either lack of or very brief valve closure could cause mean pressure to be lower downstream. Widely separated combinations of refractory period and delay time were found to produce the greatest flow-rate for a given pressure difference. The efficiency of pumping was always maximized by a long refractory period and lymphangion contraction starting when the contraction of the lymphangion immediately upstream was peaking. By means of an ex vivo experiment, it was verified that intermediate valves in a chain of pumping lymphangions can remain open, while the lymphangions on either side of the open valve continue to execute contractions. PMID:26747501

  5. Management of significant left main coronary disease before and after trans-apical transcatheter aortic valve replacement in a patient with severe and complex arterial disease.

    PubMed

    Paradis, Jean-Michel; George, Isaac; Kodali, Susheel

    2013-09-01

    We report the case of an 81-year-old woman with symptomatic severe aortic stenosis, extremely significant peripheral arterial disease, and obstructive coronary artery disease who underwent percutaneous coronary intervention via a transaxillary conduit immediately before a trans-apical transcatheter aortic valve replacement performed with a transfemoral device. After deployment of the transcatheter heart valve, there was a left main coronary obstruction and the patient required an emergent PCI. This multifaceted case clearly underlines the importance of a well functioning heart team including the interventional cardiologist, the cardiovascular surgeon, and the echocardiographer. Copyright © 2013 Wiley Periodicals, Inc.

  6. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  7. CONDUIT: A New Multidisciplinary Integration Environment for Flight Control Development

    NASA Technical Reports Server (NTRS)

    Tischler, Mark B.; Colbourne, Jason D.; Morel, Mark R.; Biezad, Daniel J.; Levine, William S.; Moldoveanu, Veronica

    1997-01-01

    A state-of-the-art computational facility for aircraft flight control design, evaluation, and integration called CONDUIT (Control Designer's Unified Interface) has been developed. This paper describes the CONDUIT tool and case study applications to complex rotary- and fixed-wing fly-by-wire flight control problems. Control system analysis and design optimization methods are presented, including definition of design specifications and system models within CONDUIT, and the multi-objective function optimization (CONSOL-OPTCAD) used to tune the selected design parameters. Design examples are based on flight test programs for which extensive data are available for validation. CONDUIT is used to analyze baseline control laws against pertinent military handling qualities and control system specifications. In both case studies, CONDUIT successfully exploits trade-offs between forward loop and feedback dynamics to significantly improve the expected handling, qualities and minimize the required actuator authority. The CONDUIT system provides a new environment for integrated control system analysis and design, and has potential for significantly reducing the time and cost of control system flight test optimization.

  8. Urinary conduits in gynecologic oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hancock, K.C.; Copeland, L.J.; Gershenson, D.M.

    1986-05-01

    Over an 11-year period (1971 to 1981), 212 urinary conduit surgeries were performed by the Department of Gynecology at the University of Texas, M. D. Anderson Hospital and Tumor Institute at Houston. The urinary diversions were performed as part of the pelvic exenteration operation in 154 patients, for radiation injury in 48 patients, and for palliation of disease recurrence in ten patients. Ninety-three percent had prior pelvic radiotherapy. Various segments of the gastrointestinal tract were used, including the ileum (102), sigmoid colon (99), transverse colon (four), jejunum (four), and others (three). Fifty percent of abnormal preoperative intravenous pyelograms reverted tomore » normal after urinary diversion. Revision of the stoma was required in 6%. Other complications included infection (18%), renal loss (17%), and urinary leaks and fistulae (3%). The overall perioperative mortality was 7%, decreasing from 11% in the first five years to 3% during the last six years. Ureteral stents were routinely used. When selecting a segment of bowel for a urinary conduit, both tissue quality and mobility are important. Mortality and morbidity of urinary conduit surgery continues to decrease with experience.« less

  9. Synergistic effects of micropatterned biodegradable conduits and Schwann cells on sciatic nerve regeneration

    NASA Astrophysics Data System (ADS)

    Rutkowski, Gregory E.; Miller, Cheryl A.; Jeftinija, Srdija; Mallapragada, Surya K.

    2004-09-01

    This paper describes a novel biodegradable conduit that provides a combination of physical, chemical and biological cues at the cellular level to facilitate peripheral nerve regeneration. The conduit consists of a porous poly(D,L-lactic acid) (PDLLA) tubular support structure with a micropatterned inner lumen. Schwann cells were pre-seeded into the lumen to provide additional trophic support. Conduits with micropatterned inner lumens pre-seeded with Schwann cells (MS) were fabricated and compared with three types of conduits used as controls: M (conduits with micropatterned inner lumens without pre-seeded Schwann cells), NS (conduits without micropatterned inner lumens pre-seeded with Schwann cells) and N (conduits without micropatterned inner lumens, without pre-seeded Schwann cells). The conduits were implanted in rats with 1 cm sciatic nerve transections and the regeneration and functional recovery were compared in the four different cases. The number or size of regenerated axons did not vary significantly among the different conduits. The time of recovery, and the sciatic function index, however, were significantly enhanced using the MS conduits, based on qualitative observations as well as quantitative measurements using walking track analysis. This demonstrates that biodegradable micropatterned conduits pre-seeded with Schwann cells that provide a combination of physical, chemical and biological guidance cues for regenerating axons at the cellular level offer a better alternative for repairing sciatic nerve transactions than conventional biodegradable conduits.

  10. In Vitro Study of Directly Bioprinted Perfusable Vasculature Conduits.

    PubMed

    Zhang, Yahui; Yu, Yin; Akkouch, Adil; Dababneh, Amer; Dolati, Farzaneh; Ozbolat, Ibrahim T

    2015-01-01

    The ability to create three dimensional (3D) thick tissues is still a major tissue engineering challenge. It requires the development of a suitable vascular supply for an efficient media exchange. An integrated vasculature network is particularly needed when building thick functional tissues and/or organs with high metabolic activities, such as the heart, liver and pancreas. In this work, human umbilical vein smooth muscle cells (HUVSMCs) were encapsulated in sodium alginate and printed in the form of vasculature conduits using a coaxial deposition system. Detailed investigations were performed to understand the dehydration, swelling and degradation characteristics of printed conduits. In addition, because perfusional, permeable and mechanical properties are unique characteristics of natural blood vessels, for printed conduits these properties were also explored in this work. The results show that cells encapsulated in conduits had good proliferation activities and that their viability increased during prolonged in vitro culture. Deposition of smooth muscle matrix and collagen was observed around the peripheral and luminal surface in long-term cultured cellular vascular conduit through histology studies.

  11. Soft valves in plants

    NASA Astrophysics Data System (ADS)

    Park, Keunhwan; Tixier, Aude; Christensen, Anneline; Arnbjerg-Nielsen, Sif; Zwieniecki, Maciej; Jensen, Kaare

    2017-11-01

    Water and minerals flow from plant roots to leaves in the xylem, an interconnected network of vascular conduits that spans the full length of the organism. When a plant is subjected to drought stress, air pockets can spread inside the xylem, threatening the survival of the plant. Many plants prevent propagation of air by using hydrophobic nano-membranes in the ``pit'' pores that link adjacent xylem cells. This adds considerable resistance to flow. Interestingly, torus-margo pit pores in conifers are open and offer less resistance. To prevent propagation of air, conifers use a soft gating mechanism, which relies on hydrodynamic interactions between the xylem liquid and the elastic pit. However, it is unknown exactly how it is able to combine the seemingly antagonist functions of high permeability and resistance to propagation of air. We conduct experiments on biomimetic pores to elucidate the flow regulation mechanism. The design of plant valves is compared to other natural systems and optimal strategies are discussed. This work was supported by a research Grant (13166) from VILLUM FONDEN.

  12. Engineering a multimodal nerve conduit for repair of injured peripheral nerve

    NASA Astrophysics Data System (ADS)

    Quigley, A. F.; Bulluss, K. J.; Kyratzis, I. L. B.; Gilmore, K.; Mysore, T.; Schirmer, K. S. U.; Kennedy, E. L.; O'Shea, M.; Truong, Y. B.; Edwards, S. L.; Peeters, G.; Herwig, P.; Razal, J. M.; Campbell, T. E.; Lowes, K. N.; Higgins, M. J.; Moulton, S. E.; Murphy, M. A.; Cook, M. J.; Clark, G. M.; Wallace, G. G.; Kapsa, R. M. I.

    2013-02-01

    Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the body (usually sensory nerves). Functional recovery is often suboptimal and associated with loss of sensation from the tissue innervated by the harvested nerve. The challenges that persist with nerve repair have resulted in development of nerve guides or conduits from non-neural biological tissues and various polymers to improve the prognosis for the repair of damaged nerves in the PNS. This study describes the design and fabrication of a multimodal controlled pore size nerve regeneration conduit using polylactic acid (PLA) and (PLA):poly(lactic-co-glycolic) acid (PLGA) fibers within a neurotrophin-enriched alginate hydrogel. The nerve repair conduit design consists of two types of PLGA fibers selected specifically for promotion of axonal outgrowth and Schwann cell growth (75:25 for axons; 85:15 for Schwann cells). These aligned fibers are contained within the lumen of a knitted PLA sheath coated with electrospun PLA nanofibers to control pore size. The PLGA guidance fibers within the nerve repair conduit lumen are supported within an alginate hydrogel impregnated with neurotrophic factors (NT-3 or BDNF with LIF, SMDF and MGF-1) to provide neuroprotection, stimulation of axonal growth and Schwann cell migration. The conduit was used to promote repair of transected sciatic nerve in rats over a period of 4 weeks. Over this period, it was observed that over-grooming and self-mutilation (autotomy) of the limb implanted with the conduit was significantly reduced in rats implanted with the full-configuration conduit compared to rats implanted with conduits containing only an alginate

  13. Guidance for removal of fetal bovine serum from cryopreserved heart valve processing.

    PubMed

    Brockbank, Kelvin G M; Heacox, Albert E; Schenke-Layland, Katja

    2011-01-01

    Bovine serum is commonly used in cryopreservation of allogeneic heart valves; however, bovine serum carries a risk of product adulteration by contamination with bovine-derived infectious agents. In this study, we compared fresh and cryopreserved porcine valves that were processed by 1 of 4 cryopreservation formulations, 3 of which were serum-free and 1 that utilized bovine serum with 1.4 M dimethylsulfoxide. In the first serum-free group, bovine serum was simply removed from the cryopreservation formulation. The second serum-free formulation had a higher cryoprotectant concentration, i.e. 2 M dimethylsulfoxide, in combination with a serum-free solution. A colloid, dextran 40, was added to the third serum-free group with 2 M dimethylsulfoxide due to theoretical concerns that removal of serum might increase the incidence of tissue cracking. Upon rewarming, the valves were inspected and subjected to a battery of tests. Gross pathology revealed conduit cracking in 1 of 98 frozen heart valves. Viability data for the cryopreserved groups versus the fresh group demonstrated a loss of viability in half of the comparisons (p < 0.05). No significant differences were observed between any of the cryopreserved groups, with or without bovine serum. Neither routine histology, autofluorescence-based multiphoton imaging nor semiquantitative second-harmonic generation microscopy of extracellular matrix components revealed any statistically significant differences. Biomechanics analyses also revealed no significant differences. Our results demonstrate that bovine serum can be safely removed from heart valve processing and that a colloid to prevent cracking was not required. This study provides guidance for the assessment of changes in cryopreservation procedures for tissues. Copyright © 2010 S. Karger AG, Basel.

  14. Solute Migration from the Aquifer Matrix into a Solution Conduit and the Reverse.

    PubMed

    Li, Guangquan; Field, Malcolm S

    2016-09-01

    A solution conduit has a permeable wall allowing for water exchange and solute transfer between the conduit and its surrounding aquifer matrix. In this paper, we use Laplace Transform to solve a one-dimensional equation constructed using the Euler approach to describe advective transport of solute in a conduit, a production-value problem. Both nonuniform cross-section of the conduit and nonuniform seepage at the conduit wall are considered in the solution. Physical analysis using the Lagrangian approach and a lumping method is performed to verify the solution. Two-way transfer between conduit water and matrix water is also investigated by using the solution for the production-value problem as a first-order approximation. The approximate solution agrees well with the exact solution if dimensionless travel time in the conduit is an order of magnitude smaller than unity. Our analytical solution is based on the assumption that the spatial and/or temporal heterogeneity in the wall solute flux is the dominant factor in the spreading of spring-breakthrough curves, and conduit dispersion is only a secondary mechanism. Such an approach can lead to the better understanding of water exchange and solute transfer between conduits and aquifer matrix. Euler and Lagrangian approaches are used to solve transport in conduit. Two-way transfer between conduit and matrix is investigated. The solution is applicable to transport in conduit of persisting solute from matrix. © 2016, National Ground Water Association.

  15. Acute postoperative obstruction of extracardiac conduit due to separation of thin fibrous peel.

    PubMed

    Agarwal, K C; Edwards, W D; Puga, F J; Mair, D D

    1982-03-01

    Late postoperative obstruction of extracardiac conduits may occur in some patients and may result from one of several mechanisms. Severe intraoperative or early postoperative obstruction of such conduits is very rare. Herein we describe a case of acute, severe, early postoperative obstruction of an extracardiac conduit; this followed partial excision and replacement of a Hancock conduit in which late postoperative calcific valvular stenosis had occurred. Unexpectedly elevated right ventricular pressure should suggest the possibility of acute conduit obstruction. In cases with partial conduit replacement, the remaining segment should be carefully inspected for the presence of a peel; if a peel is present, it should be removed from the conduit even if it is considered thin and nonobstructive.

  16. Momentum transfer conduits -- A new microscopic look at porous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moaveni, S.

    In this paper, the flow of fluid through porous media is investigated on a microscopic scale by representing a porous medium by an assemblage of hypothetical conduits through which the fluid momentum is transferred across the medium. It is shown that the rate of transfer of fluid momentum depends on the geometrical structure of the conduits such as the number density of momentum transfer conduits (MTCs), the length distribution and the directional distribution of these hypothetical conduits. In addition an expression for the total number of momentum transfer conduits reaching an arbitrary areal element is developed. Finally, an average heightmore » normal to an arbitrary areal element at which the MTCs were last discharged is formulated. This idea leads to definition of momentum thickness, which in turn may be used to define an effective (pseudo) viscosity for a given porous medium.« less

  17. Integrating bio-prosthetic valves in the Fontan operation - Novel treatment to control retrograde flow in caval veins

    NASA Astrophysics Data System (ADS)

    Vukicevic, Marija; Conover, Timothy; Zhou, Jian; Hsia, Tain-Yen; Figliola, Richard

    2012-11-01

    For a child born with only one functional heart ventricle, the sequence of palliative surgeries typically culminates in the Fontan operation. This procedure is usually successful initially, but leads to later complications, for reasons not fully understood. Examples are respiratory-dependent retrograde flows in the caval and hepatic veins, and increased pulmonary vascular resistance (PVR), hypothesized to be responsible for elevated pressure in the liver and disease of the liver and intestines. Here we study the parameters responsible for retrograde flows in the inferior vena cava (IVC) and hepatic vein (HV), and investigate two novel interventions to control retrograde flow: implanting either a Medtronic Contegra valved conduit or an Edwards lifescience pericardial aortic valve in the IVC or HV. We performed the experiments in a multi-scale, patient specific mock circuit, with normal and elevated PVR, towards the optimization of the Fontan circulation. The results show that both valves can significantly reduce retrograde flows in the veins, suggesting potential advantages in the treatment of the patients with congenital heart diseases. Fondation Leducq

  18. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    PubMed

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  19. Water displacement mercury pump

    DOEpatents

    Nielsen, Marshall G.

    1985-01-01

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  20. Water displacement mercury pump

    DOEpatents

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  1. A one-dimensional heat-transport model for conduit flow in karst aquifers

    USGS Publications Warehouse

    Long, Andrew J.; Gilcrease, P.C.

    2009-01-01

    A one-dimensional heat-transport model for conduit flow in karst aquifers is presented as an alternative to two or three-dimensional distributed-parameter models, which are data intensive and require knowledge of conduit locations. This model can be applied for cases where water temperature in a well or spring receives all or part of its water from a phreatic conduit. Heat transport in the conduit is simulated by using a physically-based heat-transport equation that accounts for inflow of diffuse flow from smaller openings and fissures in the surrounding aquifer during periods of low recharge. Additional diffuse flow that is within the zone of influence of the well or spring but has not interacted with the conduit is accounted for with a binary mixing equation to proportion these different water sources. The estimation of this proportion through inverse modeling is useful for the assessment of contaminant vulnerability and well-head or spring protection. The model was applied to 7 months of continuous temperature data for a sinking stream that recharges a conduit and a pumped well open to the Madison aquifer in western South Dakota. The simulated conduit-flow fraction to the well ranged from 2% to 31% of total flow, and simulated conduit velocity ranged from 44 to 353 m/d.

  2. Superconducting cable-in-conduit low resistance splice

    DOEpatents

    Artman, Thomas A.

    2003-06-24

    A low resistance splice connects two cable-in-conduit superconductors to each other. Dividing collars for arranging sub-cable units from each conduit are provided, along with clamping collars for mating each sub-cable wire assembly to form mated assemblies. The mated assemblies ideally can be accomplished by way of splicing collar. The mated assemblies are cooled by way of a flow of coolant, preferably helium. A method for implementing such a splicing is also described.

  3. Understanding Volcanic Conduit Dynamics: from Experimental Fragmentation to Volcanic Eruptions

    NASA Astrophysics Data System (ADS)

    Arciniega-Ceballos, A.; Alatorre-Ibarguengoitia, M. A.; Scheu, B.; Dingwell, D. B.

    2011-12-01

    The investigation of conduit dynamics at high pressure, under controlled laboratory conditions is a powerful tool to understand the physics behind volcanic processes before an eruption. In this work, we analyze the characteristics of the seismic response of an "experimental volcano" focusing on the dynamics of the conduit behavior during the fragmentation process of volcanic rocks. The "experimental volcano" is represented by a shock tube apparatus, which consists of a low-pressure voluminous tank (3 x 0.40 m), for sample recovery; and a high-pressure pipe-like conduit (16.5 x 2,5 cm), which represents the volcanic source mechanism, where rock samples are pressurized and fragmented. These two serial steel pipes are connected and sealed by a set of diaphragms that bear pressures in a range of 4 to 20 MPa. The history of the overall process of an explosion consists of four steps: 1) the slow pressurization of the pipe-like conduit filled with solid pumice and gas, 2) the sudden removal of the diaphragms, 3) the rapid decompression of the system and 4) the ejection of the gas-particle mixture. Each step imprints distinctive features on the microseismic records, reflecting the conduit dynamics during the explosion. In this work we show how features such as waveform characteristics, the three components of the force system acting on the conduit, the independent components of the moment tensor, the volumetric change of the source mechanism, the arrival time of the shock wave and its velocity, are quantified from the experimental microseismic data. Knowing these features, each step of the eruptive process, the conduit conditions and the source mechanism characteristics can be determined. The procedure applied in this experimental approach allows the use of seismic field data to estimate volcanic conduit conditions before an eruption takes place. We state on the hypothesis that the physics behind the pressurization and depressurization process of any conduit is the same

  4. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  5. Environmental tracers as indicators of karst conduits in groundwater in South Dakota, USA

    USGS Publications Warehouse

    Long, Andrew J.; Sawyer, J.F.; Putnam, L.D.

    2008-01-01

    Environmental tracers sampled from the carbonate Madison aquifer on the eastern flank of the Black Hills, South Dakota, USA indicated the approximate locations of four major karst conduits. Contamination issues are a major concern because these conduits are characterized by direct connections to sinking streams, high groundwater velocities, and proximity to public water supplies. Objectives of the study were to estimate approximate conduit locations and assess possible anthropogenic influences associated with conduits. Anomalies of young groundwater based on chlorofluorocarbons (CFCs), tritium, and electrical conductivity (EC) indicated fast moving, focused flow and thus the likely presence of conduits. ??18O was useful for determining sources of recharge for each conduit, and nitrate was a useful tracer for assessing flow paths for anthropogenic influences. Two of the four conduits terminate at or near a large spring complex. CFC apparent ages ranged from 15 years near conduits to >50 years in other areas. Nitrate-N concentrations >0.4 mg/L in groundwater were associated with each of the four conduits compared with concentrations ranging from <0.1 to 0.4 mg/L in other areas. These higher nitrate-N concentrations probably do not result from sinking streams but rather from other areas of infiltration. ?? Springer-Verlag 2007.

  6. Results and analysis of the hot-spot temperature experiment for a cable-in-conduit conductor with thick conduit

    NASA Astrophysics Data System (ADS)

    Sedlak, Kamil; Bruzzone, Pierluigi

    2015-12-01

    In the design of future DEMO fusion reactor a long time constant (∼23 s) is required for an emergency current dump in the toroidal field (TF) coils, e.g. in case of a quench detection. This requirement is driven mainly by imposing a limit on forces on mechanical structures, namely on the vacuum vessel. As a consequence, the superconducting cable-in-conduit conductors (CICC) of the TF coil have to withstand heat dissipation lasting tens of seconds at the section where the quench started. During that time, the heat will be partially absorbed by the (massive) steel conduit and electrical insulation, thus reducing the hot-spot temperature estimated strictly from the enthalpy of the strand bundle. A dedicated experiment has been set up at CRPP to investigate the radial heat propagation and the hot-spot temperature in a CICC with a 10 mm thick steel conduit and a 2 mm thick glass epoxy outer electrical insulation. The medium size, ∅ = 18 mm, NbTi CICC was powered by the operating current of up to 10 kA. The temperature profile was monitored by 10 temperature sensors. The current dump conditions, namely the decay time constant and the quench detection delay, were varied. The experimental results show that the thick conduit significantly contributes to the overall enthalpy balance, and consequently reduces the amount of copper required for the quench protection in superconducting cables for fusion reactors.

  7. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    PubMed

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  8. Conduit Coating Abrasion Testing

    NASA Technical Reports Server (NTRS)

    Sullivan, Mary K.

    2013-01-01

    During my summer internship at NASA I have been working alongside the team members of the RESTORE project. Engineers working on the RESTORE project are creating ·a device that can go into space and service satellites that no longer work due to gas shortage or other technical difficulties. In order to complete the task of refueling the satellite a hose needs to be used and covered with a material that can withstand effects of space. The conduit coating abrasion test will help the researchers figure out what type of thermal coating to use on the hose that will be refueling the satellites. The objective of the project is to determine whether or not the conduit coating will withstand the effects of space. For the RESTORE project I will help with various aspects of the testing that needed to be done in order to determine which type of conduit should be used for refueling the satellite. During my time on the project I will be assisting with wiring a relay board that connected to the test set up by soldering, configuring wires and testing for continuity. Prior to the testing I will work on creating the testing site and help write the procedure for the test. The testing will take place over a span of two weeks and lead to an informative conclusion. Working alongside various RESTORE team members I will assist with the project's documentation and records. All in all, throughout my internship at NASA I hope to learn a number of valuable skills and be a part of a hard working team of engineers.

  9. Incorporating seismic observations into 2D conduit flow modeling

    NASA Astrophysics Data System (ADS)

    Collier, L.; Neuberg, J.

    2006-04-01

    Conduit flow modeling aims to understand the conditions of magma at depth, and to provide insight into the physical processes that occur inside the volcano. Low-frequency events, characteristic to many volcanoes, are thought to contain information on the state of magma at depth. Therefore, by incorporating information from low-frequency seismic analysis into conduit flow modeling a greater understanding of magma ascent and its interdependence on magma conditions and physical processes is possible. The 2D conduit flow model developed in this study demonstrates the importance of lateral pressure and parameter variations on overall magma flow dynamics, and the substantial effect bubbles have on magma shear viscosity and on magma ascent. The 2D nature of the conduit flow model developed here allows in depth investigation into processes which occur at, or close to the wall, such as magma cooling and brittle failure of melt. These processes are shown to have a significant effect on magma properties and therefore, on flow dynamics. By incorporating low-frequency seismic information, an advanced conduit flow model is developed including the consequences of brittle failure of melt, namely friction-controlled slip and gas loss. This model focuses on the properties and behaviour of magma at depth within the volcano, and their interaction with the formation of seismic events by brittle failure of melt.

  10. Vitrification and xenografting of human ovarian tissue.

    PubMed

    Amorim, Christiani Andrade; Dolmans, Marie-Madeleine; David, Anu; Jaeger, Jonathan; Vanacker, Julie; Camboni, Alessandra; Donnez, Jacques; Van Langendonckt, Anne

    2012-11-01

    To assess the efficiency of two vitrification protocols to cryopreserve human preantral follicles with the use of a xenografting model. Pilot study. Gynecology research unit in a university hospital. Ovarian biopsies were obtained from seven women aged 30-41 years. Ovarian tissue fragments were subjected to one of three cryopreservation protocols (slow freezing, vitrification protocol 1, and vitrification protocol 2) and xenografted for 1 week to nude mice. The number of morphologically normal follicles after cryopreservation and grafting and fibrotic surface area were determined by histologic analysis. Apoptosis was assessed by the TUNEL method. Morphometric analysis of TUNEL-positive surface area also was performed. Follicle proliferation was evaluated by immunohistochemistry. After xenografting, a difference was observed between the cryopreservation procedures applied. According to TUNEL analysis, both vitrification protocols showed better preservation of preantral follicles than the conventional freezing method. Moreover, histologic evaluation showed a significantly higher proportion of primordial follicles in vitrified (protocol 2)-warmed ovarian tissue than in frozen-thawed tissue. The proportion of growing follicles and fibrotic surface area was similar in all groups. Vitrification procedures appeared to preserve not only the morphology and survival of preantral follicles after 1 week of xenografting, but also their ability to resume folliculogenesis. In addition, vitrification protocol 2 had a positive impact on the quiescent state of primordial follicles after xenografting. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Check valve

    DOEpatents

    Upton, Hubert Allen; Garcia, Pablo

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

  12. Check valve

    DOEpatents

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  13. Controlling Wavebreaking in a Viscous Fluid Conduit

    NASA Astrophysics Data System (ADS)

    Anderson, Dalton; Maiden, Michelle; Hoefer, Mark

    2015-11-01

    This poster will present a new technique in the experimental investigation of dispersive hydrodynamics. In shallow water flows, internal ocean waves, superfluids, and optical media, wave breaking can be resolved by a dispersive shock wave (DSW). In this work, an experimental method to control the location of DSW formation (gradient catastrophe) is explained. The central idea is to convert an initial value problem (Riemann problem) into an equivalent boundary value problem. The system to which this technique is applied is a fluid conduit resulting from high viscosity contrast between a buoyant interior and heavier exterior fluid. The conduit cross-sectional area is modeled by a nonlinear, conservative, dispersive, third order partial differential equation. Using this model, the aim is to predict the breaking location of a DSW by controlling one boundary condition. An analytical expression for this boundary condition is derived by solving the dispersionless equation backward in time from the desired step via the method of characteristics. This is used in experiment to generate an injection rate profile for a high precision piston pump. This translates to the desired conduit shape. Varying the jump height and desired breaking location indicates good control of DSW formation. This result can be improved by deriving a conduit profile by numerical simulation of the full model equation. Controlling the breaking location of a DSW allows for the investigation of dynamics independent of the boundary. Support provided by NSF CAREER DMS-1255422 , NSF EXTREEMS.

  14. Novel technique for airless connection of artificial heart to vascular conduits.

    PubMed

    Karimov, Jamshid H; Gao, Shengqiang; Dessoffy, Raymond; Sunagawa, Gengo; Sinkewich, Martin; Grady, Patrick; Sale, Shiva; Moazami, Nader; Fukamachi, Kiyotaka

    2017-12-01

    Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs. Such air emboli block blood flow to these areas and are detrimental to long-term survival. A correctly managed pump-to-conduit connection prevents air from collecting in the pump and conduits. To further optimize pump-connection techniques, we have developed a novel connecting sleeve that enables airless connection of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) to the conduits. In this brief report, we describe the connecting sleeve design and our initial results from two acute in vivo implantations using a scaled-down version of the CFTAH.

  15. Generation of Complex Karstic Conduit Networks with a Hydro-chemical Model

    NASA Astrophysics Data System (ADS)

    De Rooij, R.; Graham, W. D.

    2016-12-01

    The discrete-continuum approach is very well suited to simulate flow and solute transport within karst aquifers. Using this approach, discrete one-dimensional conduits are embedded within a three-dimensional continuum representative of the porous limestone matrix. Typically, however, little is known about the geometry of the karstic conduit network. As such the discrete-continuum approach is rarely used for practical applications. It may be argued, however, that the uncertainty associated with the geometry of the network could be handled by modeling an ensemble of possible karst conduit networks within a stochastic framework. We propose to generate stochastically realistic karst conduit networks by simulating the widening of conduits as caused by the dissolution of limestone over geological relevant timescales. We illustrate that advanced numerical techniques permit to solve the non-linear and coupled hydro-chemical processes efficiently, such that relatively large and complex networks can be generated in acceptable time frames. Instead of specifying flow boundary conditions on conduit cells to recharge the network as is typically done in classical speleogenesis models, we specify an effective rainfall rate over the land surface and let model physics determine the amount of water entering the network. This is advantageous since the amount of water entering the network is extremely difficult to reconstruct, whereas the effective rainfall rate may be quantified using paleoclimatic data. Furthermore, we show that poorly known flow conditions may be constrained by requiring a realistic flow field. Using our speleogenesis model we have investigated factors that influence the geometry of simulated conduit networks. We illustrate that our model generates typical branchwork, network and anastomotic conduit systems. Flow, solute transport and water ages in karst aquifers are simulated using a few illustrative networks.

  16. Fibrin matrix for suspension of regenerative cells in an artificial nerve conduit.

    PubMed

    Kalbermatten, D F; Kingham, P J; Mahay, D; Mantovani, C; Pettersson, J; Raffoul, W; Balcin, H; Pierer, G; Terenghi, G

    2008-06-01

    Peripheral nerve injury presents with specific problems of neuronal reconstructions, and from a clinical viewpoint a tissue engineering approach would facilitate the process of repair and regeneration. We have previously used artificial nerve conduits made from bioresorbable poly-3-hydroxybutyrate (PHB) in order to refine the ways in which peripheral nerves are repaired and reconnected to the target muscles and skin. The addition of Schwann cells (SC) or differentiated mesenchymal stem cells (dMSC) to the conduits enhances regeneration. In this study, we have used a matrix based on fibrin (Tisseel) to fill optimally the nerve-conduits with cells. In vitro analysis showed that both SC and MSC adhered significantly better to PHB in the presence of fibrin and cells continued to maintain their differentiated state. Cells were more optimally distributed throughout the conduit when seeded in fibrin than by delivery in growth medium alone. Transplantation of the nerve conduits in vivo showed that cells in combination with fibrin matrix significantly increased nerve regeneration distance (using PGP9.5 and S100 distal and proximal immunohistochemistry) when compared with empty PHB conduits. This study shows the beneficial combinatory effect of an optimised matrix, cells and conduit material as a step towards bridging nerve gaps which should ultimately lead to improved functional recovery following nerve injury.

  17. In vivo bioluminescence imaging using orthotopic xenografts towards patient's derived-xenograft Medulloblastoma models.

    PubMed

    Asadzadeh, Fatemeh; Ferrucci, Veronica; DE Antonellis, Pasqualino; Zollo, Massimo

    2017-03-01

    Medulloblastoma is a cerebellar neoplasia of the central nervous system. Four molecular subgrups have been identified (MBWNT, MBSHH, MBgroup3 and MBgroup4) with distinct genetics and clinical outcome. Among these, MBgroup3-4 are highly metastatic with the worst prognosis. The current standard therapy includes surgery, radiation and chemotherapy. Thus, specific treatments adapted to cure those different molecular subgroups are needed. The use of orthotopic xenograft models, together with the non-invasive in vivo biolumiscence imaging (BLI) technology, is emerging during preclinical studies to test novel therapeutics for medulloblastoma treatment. Orthotopic MB xenografts were performed by injection of Daoy-luc cells, that had been previously infected with lentiviral particles to stably express luciferase gene, into the fourth right ventricle of the cerebellum of ten nude mice. For the implantation, specific stereotactic coordinates were used. Seven days after the implantation the mice were imaged by acquisitions of bioluminescence imaging (BLI) using IVIS 3D Illumina Imaging System (Xenogen). Tumor growth was evaluated by quantifying the bioluminescence signals using the integrated fluxes of photons within each area of interest using the Living Images Software Package 3.2 (Xenogen-Perkin Elmer). Finally, histological analysis using hematoxylin-eosin staining was performed to confirm the presence of tumorigenic cells into the cerebellum of the mice. We describe a method to use the in vivo bioluminescent imaging (BLI) showing the potential to be used to investigate the potential antitumorigenic effects of a drug for in vivo medulloblastoma treatment. We also discuss other studies in which this technology has been applied to obtain a more comprehensive knowledge of medulloblastoma using orthotopic xenograft mouse models. There is a need to develop patient's derived-xenograft (PDX) model systems to test novel drugs for medulloblastoma treatment within each molecular sub

  18. Blood flow speed of the gastric conduit assessed by indocyanine green fluorescence

    PubMed Central

    Koyanagi, Kazuo; Ozawa, Soji; Oguma, Junya; Kazuno, Akihito; Yamazaki, Yasushi; Ninomiya, Yamato; Ochiai, Hiroki; Tachimori, Yuji

    2016-01-01

    Abstract Anastomotic leakage is considered as an independent risk factor for postoperative mortality after esophagectomy, and an insufficient blood flow in the reconstructed conduit may be a risk factor of anastomotic leakage. We investigated the clinical significance of blood flow visualization by indocyanine green (ICG) fluorescence in the gastric conduit as a means of predicting the leakage of esophagogastric anastomosis after esophagectomy. Forty patients who underwent an esophagectomy with gastric conduit reconstruction were prospectively investigated. ICG fluorescence imaging of the gastric conduit was detected by a near-infrared camera system during esophagectomy and correlated with clinical parameters or surgical outcomes. In 25 patients, the flow speed of ICG fluorescence in the gastric conduit wall was simultaneous with that of the greater curvature vessels (simultaneous group), whereas in 15 patients this was slower than that of the greater curvature vessels (delayed group). The reduced speed of ICG fluorescence stream in the gastric conduit wall was associated with intraoperative blood loss (P = 0.008). Although anastomotic leakage was not found in the simultaneous group, it occurred in 7 patients of the delayed group (P < 0.001). A flow speed of ICG fluorescence in the gastric conduit wall of 1.76 cm/s or less was determined by a receiver operating characteristic (ROC) curve, identified as a significant independent predictor of anastomotic leakage after esophagectomy (P = 0.004). This preliminary study demonstrates that intraoperative evaluation of blood flow speed by ICG fluorescence in the gastric conduit wall is a useful means to predict the risk of anastomotic leakage after esophagectomy. PMID:27472732

  19. A polymer foam conduit seeded with Schwann cells promotes guided peripheral nerve regeneration.

    PubMed

    Hadlock, T; Sundback, C; Hunter, D; Cheney, M; Vacanti, J P

    2000-04-01

    Alternatives to autografts have long been sought for use in bridging neural gaps. Many entubulation materials have been studied, although with generally disappointing results in comparison with autografts. The purpose of this study was to design a more effective neural guidance conduit, to introduce Schwann cells into the conduit, and to determine regenerative capability through it in an in vivo model. A novel, fully biodegradable polymer conduit was designed and fabricated for use in peripheral nerve repair, which approximates the macro- and microarchitecture of native peripheral nerves. It comprised a series of longitudinally aligned channels, with diameters ranging from 60 to 550 microns. The lumenal surfaces promoted the adherence of Schwann cells, whose presence is known to play a key role in nerve regeneration. This unique channel architecture increased the surface area available for Schwann cell adherence up to five-fold over that available through a simple hollow conduit. The conduit was composed of a high-molecular-weight copolymer of lactic and glycolic acids (PLGA) (MW 130,000) in an 85:15 monomer ratio. A novel foam-processing technique, employing low-pressure injection molding, was used to create highly porous conduits (approximately 90% pore volume) with continuous longitudinal channels. Using this technique, conduits were constructed containing 1, 5, 16, 45, or more longitudinally aligned channels. Prior to cellular seeding of these conduits, the foams were prewet with 50% ethanol, flushed with physiologic saline, and coated with laminin solution (10 microg/mL). A Schwann cell suspension was dynamically introduced into these processed foams at a concentration of 5 X 10(5) cells/mL, using a simple bioreactor flow loop. In vivo regeneration studies were carried out in which cell-laden five-channel polymer conduits (individual channel ID 500 microm, total conduit OD 2.3 mm) were implanted across a 7-mm gap in the rat sciatic nerve (n = 4), and midgraft

  20. 30 CFR 75.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... conduits enclosing power conductors. 75.700 Section 75.700 Mineral Resources MINE SAFETY AND HEALTH... Grounding § 75.700 Grounding metallic sheaths, armors, and conduits enclosing power conductors. [Statutory Provisions] All metallic sheaths, armors, and conduits enclosing power conductors shall be electrically...

  1. 30 CFR 77.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... conduits enclosing power conductors. 77.700 Section 77.700 Mineral Resources MINE SAFETY AND HEALTH..., and conduits enclosing power conductors. Metallic sheaths, armors, and conduits enclosing power conductors shall be electrically continuous throughout and shall be grounded by methods approved by an...

  2. 30 CFR 75.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... conduits enclosing power conductors. 75.700 Section 75.700 Mineral Resources MINE SAFETY AND HEALTH... Grounding § 75.700 Grounding metallic sheaths, armors, and conduits enclosing power conductors. [Statutory Provisions] All metallic sheaths, armors, and conduits enclosing power conductors shall be electrically...

  3. 30 CFR 77.700 - Grounding metallic sheaths, armors, and conduits enclosing power conductors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... conduits enclosing power conductors. 77.700 Section 77.700 Mineral Resources MINE SAFETY AND HEALTH..., and conduits enclosing power conductors. Metallic sheaths, armors, and conduits enclosing power conductors shall be electrically continuous throughout and shall be grounded by methods approved by an...

  4. Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation

    PubMed Central

    Spina, Roberto; Anthony, Chris; Muller, David WM

    2015-01-01

    Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674

  5. Banking cryopreserved heart valves in Europe: assessment of a 5-year operation in an international tissue bank in Brussels.

    PubMed

    Goffin, Y; Grandmougin, D; Van Hoeck, B

    1996-01-01

    The heart valve bank of the European Homograft Bank has been set up in 1988 to meet the growing demand of cardiac surgeons for various sized and quality controlled cryopreserved homografts. Heart valve donors less than 60 years of age were classified in 3 categories: multiorgan donors with non transplantable hearts, recipients of cardiac transplantation and non beating heart cadavers with a warm ischemic time of less than 6 hours. Past history and biology were checked for transmissible diseases. Preparation, progressive freezing and storage in liquid nitrogen vapors, and quality control were according to the standards of the Belgian Ministry of Health. From end January 1989 to end May 1994, 989 homograft valves were cryopreserved (514 pulmonary, 475 aortic and 3 mitral) whereas 962 valves were discarded. The first cause of rejection being a major macroscopic lesion (41.48%). 138 hearts accepted at inspection were contaminated and 43 cases remained so after antibiotics. 38 cases were positive for hepatitis B or C. Complication at distribution and thawing included 10 instances of bag rupture and 15 of transversal fracture through the wall of the conduit. 477 aortic, 474 pulmonary valves as well as one mitral were implanted between May 1989 and May 1994, either for left or right ventricular outflow tract reconstruction. In the left ventricular outflow tract series 111 aortic and 23 pulmonary homograft valves were used in cases of native endocarditis, prosthetic endocarditis or recurrent endocarditis after homograft implantation. 9.6% of the requests could no be satisfied. Regular follow up information was available from 382 implants-40.1% only. The assessment of 5 years operation of the heart valve bank indicates: 1) the efficiency of selecting, cryopreserving and allocating quality controlled homograft valves from a large pool of donor hearts provided by a network of hospitals; 2) the difficulty of obtaining regular follow up information on the implants.

  6. Cryovolcanic Conduit Evolution and Eruption on Icy Satellites

    NASA Astrophysics Data System (ADS)

    Mitchell, K. L.

    2014-12-01

    In silicate volcanism, such as on Earth or Io, eruptions typically result from fracture formation caused by interaction of tectonic stresses with inflating, pressurized magma sources, leading to transport of melt through an evolving conduit. On icy satellites the paradigm may be similar, resulting from some combination of tidal stresses and expansion of freezing water within, or near the base of, an ice shell. Such a fracture will result in eruption if mass continuity can be established, with buoyancy aided by exsolution and expansion of dissolved volatiles. After onset, conduit shape evolves due to: (1) shear-stresses or frictional erosional; (2) wallrock "bursting" due to massive wall stresses; (3) wall melting or condensation of particles due to heat transfer; or (4) changes in applied stresses. Preliminary thermodynamic and fluid mechanical analysis suggests some initial cooling during ascent resulting from exsolution and expansion of volatiles, thermally buffered by freezing, Conduit contraction may occur, and so evolution towards a deep, gas-filled plume chamber is difficult to accommodate without evoking a co-incidental process. Conduit flaring occurs near the surface where velocities are greatest, enhancing erosion. Here, viscous dissipative heating exceeds adiabatic cooling, and so some boiling (a few wt%) may occur. In contrast with silicate volcanism, decompression to below the triple point will occur within conduit, vent or jet, resulting in rapid freezing and boiling of the remaining water at a 6.8:1 ratio. Subsequent isentropic or adiabatic expansion within erupting jets may result in a few percent net of condensation or sublimation. These effects combined lead to ~4:1-7:1 solid:vapor ratios in the jet for most eruption conditions. These figures are consistent with the ~6:1 inferred in Enceladus' jets, supporting the hypothesis that the Enceladus plume draws from a subsurface body of liquids through a conduit. Similar results are anticipated if

  7. Reverse Saphenous Conduit Flap in 19 Dogs and 1 Cat.

    PubMed

    Cavalcanti, Jacqueline V J; Barry, Sabrina L; Lanz, Otto I; Barnes, Katherine; Coutin, Julia V

    2018-05-14

    The purpose of this retrospective study was to report the outcomes of 19 dogs and 1 cat undergoing reverse saphenous conduit flap between 1999 and 2016. Reverse saphenous conduit flap was used to treat traumatic wounds and wounds resulting from tumor excision in the hind limb; the majority of cases had medial shearing injuries. All animals had complete flap survival. In five animals (20%), minor donor site dehiscence occurred, which did not require surgery. Other postoperative complications included signs of severe venous congestion in one dog. Reverse saphenous conduit flap is a useful technique to repair skin defects of the distal hind limb.

  8. Combining selection valve and mixing chamber for nanoflow gradient generation: Toward developing a liquid chromatography cartridge coupled with mass spectrometer for protein and peptide analysis.

    PubMed

    Chen, Apeng; Lu, Joann J; Gu, Congying; Zhang, Min; Lynch, Kyle B; Liu, Shaorong

    2015-08-05

    Toward developing a micro HPLC cartridge, we have recently built a high-pressure electroosmotic pump (EOP). However, we do not recommend people to use this pump to deliver an organic solvent directly, because it often makes the pump rate unstable. We have experimented several approaches to address this issue, but none of them are satisfactory. Here, we develop an innovative approach to address this issue. We first create an abruption (a dead-volume) within a fluid conduit. We then utilize an EOP to withdraw, via a selection valve, a train of eluent solutions having decreasing eluting power into the fluid conduit. When these solutions are further aspirated through the dead-volume, these solutions are partially mixed, smoothening concentration transitions between two adjacent eluent solutions. As these solutions are pushed back, through the dead-volume again, a smooth gradient profile is formed. In this work, we characterize this scheme for gradient formation, and we incorporate this approach with a high-pressure EOP, a nanoliter injection valve, and a capillary column, yielding a micro HPLC system. We then couple this micro HPLC with an electrospray ionization - mass spectrometer for peptide and protein separations and identifications. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Fast-Acting Valve

    NASA Technical Reports Server (NTRS)

    Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)

    2003-01-01

    A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.

  10. Silk fibroin enhances peripheral nerve regeneration by improving vascularization within nerve conduits.

    PubMed

    Wang, Chunyang; Jia, Yachao; Yang, Weichao; Zhang, Cheng; Zhang, Kuihua; Chai, Yimin

    2018-07-01

    Silk fibroin (SF)-based nerve conduits have been widely used to bridge peripheral nerve defects. Our previous study showed that nerve regeneration in a SF-blended poly (l-lactide-co-ɛ-caprolactone) [P(LLA-CL)] nerve conduit is better than that in a P(LLA-CL) conduit. However, the involved mechanisms remain unclarified. Because angiogenesis within a nerve conduit plays an important role in nerve regeneration, vascularization of SF/P(LLA-CL) and P(LLA-CL) conduits was compared both in vitro and in vivo. In the present study, we observed that SF/P(LLA-CL) nanofibers significantly promoted fibroblast proliferation, and vascular endothelial growth factor secreted by fibroblasts seeded in SF/P(LLA-CL) nanofibers was more than seven-fold higher than that in P(LLA-CL) nanofibers. Conditioned medium of fibroblasts in the SF/P(LLA-CL) group stimulated more human umbilical vein endothelial cells (HUVEC) to form capillary-like networks and promoted faster HUVEC migration. The two kinds of nerve conduits were used to bridge 10-mm-length nerve defects in rats. At 3 weeks of reparation, the blood vessel area in the SF/P(LLA-CL) group was significantly larger than that in the P(LLA-CL) group. More regenerated axons and Schwann cells were also observed in the SF/P(LLA-CL) group, which was consistent with the results of blood vessels. Collectively, our data revealed that the SF/P(LLA-CL) nerve conduit enhances peripheral nerve regeneration by improving angiogenesis within the conduit. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2070-2077, 2018. © 2018 Wiley Periodicals, Inc.

  11. A silk sericin/silicone nerve guidance conduit promotes regeneration of a transected sciatic nerve.

    PubMed

    Xie, Hongjian; Yang, Wen; Chen, Jianghai; Zhang, Jinxiang; Lu, Xiaochen; Zhao, Xiaobo; Huang, Kun; Li, Huili; Chang, Panpan; Wang, Zheng; Wang, Lin

    2015-10-28

    Peripheral nerve gap defects lead to significant loss of sensory or motor function. Tissue engineering has become an important alternative to nerve repair. Sericin, a major component of silk, is a natural protein whose value in tissue engineering has just begun to be explored. Here, the first time use of sericin in vivo is reported as a long-term implant for peripheral nerve regeneration. A sericin nerve guidance conduit is designed and fabricated. This conduit is highly porous with mechanical strength matching peripheral nerve tissue. It supports Schwann cell proliferation and is capable of up-regulating the transcription of glial cell derived neurotrophic factor and nerve growth factor in Schwann cells. The sericin conduit wrapped with a silicone conduit (sericin/silicone double conduits) is used for bridging repair of a 5 mm gap in a rat sciatic nerve transection model. The sericin/silicone double conduits achieve functional recovery comparable to that of autologous nerve grafting as evidenced by drastically improved nerve function and morphology. Importantly, this improvement is mainly attributed to the sericin conduit as the silicone conduit alone only produces marginal functional recovery. This sericin/silicone-double-conduit strategy offers an efficient and valuable alternative to autologous nerve grafting for repairing damaged peripheral nerve. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Preliminary findings on the effects of geometry on two-phase flow through volcanic conduits

    NASA Astrophysics Data System (ADS)

    Mitchell, K. L.; Wilson, L.; Lane, S. J.; James, M. R.

    2003-04-01

    We attempt to ascertain whether some of the geometrical assumptions utilised in modelling of flows through volcanic conduits are valid. Flow is often assumed to be through a vertical conduit, but some volcanoes, such as Pu'u 'O'o (Kilauea, Hawai'i) and Stromboli (Italy), are known to exhibit inclined or more complex conduit systems. Our numerical and experimental studies have revealed that conduit inclination is a first-order influence on flow properties and eruptive style. Even a few degrees of inclination from vertical can increase gas-liquid phase separation by locally enhancing the gas volume fraction on the upper surface of the conduit. We explore the consequences of phase separation and slug flow for styles of magmatic eruption, and consider how these apply to particular eruptions. Modellers also tend to assume a simple parallel-sided geometry for volcanic conduits. Some have used a pressure-balanced assumption allowing conduits to choke and flare, resulting in higher eruption velocities. The pressure-balanced assumption is flawed in that it does not deal with the effects of compressibility and associated shocks when the flow is supersonic. Both parallel-sided and pressure-balanced assumptions avoid addressing how conduit shape evolves from an initial dyke-shaped fracture. However, we assert that evolution of conduit shape is impossible to quantify accurately using a deterministic approach. Therefore we adopt a simplified approach, with the initial conduit shape as a blade-shaped dyke, and the potential end-member as a system that is pressure-balanced up to the supersonic choking point and undetermined beyond (flow is constrained by a narrow jet envelope and not by the walls). Intermediate geometries are assumed to change quasi-steadily at locations where conduit wall stresses are high, and the consequences of these geometries are explored. We find that quite small changes in conduit geometry, which are likely to occur in volcanic systems, can have a

  13. Device and method for measuring fluid flow in a conduit having a gradual bend

    DOEpatents

    Ortiz, M.G.; Boucher, T.J.

    1998-11-10

    A system is described for measuring fluid flow in a conduit having a gradual bend or arc, and a straight section. The system includes pressure transducers, one or more disposed in the conduit on the outside of the arc, and one disposed in the conduit in a straight section thereof. The pressure transducers measure the pressure of fluid in the conduit at the locations of the pressure transducers and this information is used by a computational device to calculate fluid flow rate in the conduit. For multi-phase fluid, the density of the fluid is measured by another pair of pressure transducers, one of which is located in the conduit elevationally above the other. The computation device then uses the density measurement along with the fluid pressure measurements, to calculate fluid flow. 1 fig.

  14. Device and method for measuring fluid flow in a conduit having a gradual bend

    DOEpatents

    Ortiz, Marcos German; Boucher, Timothy J

    1998-01-01

    A system for measuring fluid flow in a conduit having a gradual bend or arc, and a straight section. The system includes pressure transducers, one or more disposed in the conduit on the outside of the arc, and one disposed in the conduit in a straight section thereof. The pressure transducers measure the pressure of fluid in the conduit at the locations of the pressure transducers and this information is used by a computational device to calculate fluid flow rate in the conduit. For multi-phase fluid, the density of the fluid is measured by another pair of pressure transducers, one of which is located in the conduit elevationally above the other. The computation device then uses the density measurement along with the fluid pressure measurements, to calculate fluid flow.

  15. Linking Volcano Infrasound Observations to Conduit Processes for Vulcanian Eruptions

    NASA Astrophysics Data System (ADS)

    Watson, L. M.; Dunham, E. M.; Almquist, M.; Mattsson, K.; Ampong, K.

    2016-12-01

    Volcano infrasound observations have been used to infer a range of eruption parameters, such as volume flux and exit velocity, with the majority of work focused on subaerial processes. Here, we propose using infrasound observations to investigate the subsurface processes of the volcanic system. We develop a one-dimensional model of the volcanic system, coupling an unsteady conduit model to a description of a volcanic jet with sound waves generated by the expansion of the jet. The conduit model describes isothermal two-phase flow with no relative motion between the phases. We are currently working on including crystals and adding conservation of energy to the governing equations. The model captures the descent of the fragmentation front into the conduit and approaches a steady state solution with choked flow at the vent. The descending fragmentation front influences the time history of mass discharge from the vent, which is linked to the infrasound signal through the volcanic jet model. The jet model is coupled to the conduit by conservation of mass, momentum, and energy. We compare simulation results for a range of models of the volcanic jet, ranging in complexity from assuming conservation of volume, as has been done in some previous infrasound studies, to solving the Euler equations for the surrounding compressible atmosphere and accounting for entrainment. Our model is designed for short-lived, impulsive Vulcanian eruptions, such as those seen at Sakurajima Volcano, with activity triggered by a sudden drop in pressure at the top of the conduit. The intention is to compare the simulated signals to observations and to devise an inverse procedure to enable inversion for conduit properties.

  16. Next generation patient-derived prostate cancer xenograft models

    PubMed Central

    Lin, Dong; Xue, Hui; Wang, Yuwei; Wu, Rebecca; Watahiki, Akira; Dong, Xin; Cheng, Hongwei; Wyatt, Alexander W; Collins, Colin C; Gout, Peter W; Wang, Yuzhuo

    2014-01-01

    There is a critical need for more effective therapeutic approaches for prostate cancer. Research in this area, however, has been seriously hampered by a lack of clinically relevant, experimental in vivo models of the disease. This review particularly focuses on the development of prostate cancer xenograft models based on subrenal capsule grafting of patients’ tumor tissue into nonobese diabetic/severe combined immunodeficient (NOD/SCID) mice. This technique allows successful development of transplantable, patient-derived cancer tissue xenograft lines not only from aggressive metastatic, but also from localized prostate cancer tissues. The xenografts have been found to retain key biological properties of the original malignancies, including histopathological and molecular characteristics, tumor heterogeneity, response to androgen ablation and metastatic ability. As such, they are highly clinically relevant and provide valuable tools for studies of prostate cancer progression at cellular and molecular levels, drug screening for personalized cancer therapy and preclinical drug efficacy testing; especially when a panel of models is used to cover a broader spectrum of the disease. These xenograft models could therefore be viewed as next-generation models of prostate cancer. PMID:24589467

  17. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside

    PubMed Central

    Saxon, John T; Allen, Keith B; Cohen, David J

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832

  18. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    PubMed

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  19. Morbidity and mortality after use of iliac conduits for endovascular aortic aneurysm repair.

    PubMed

    Gupta, Prateek K; Sundaram, Abhishek; Kent, K Craig

    2015-07-01

    Although placement of an open iliac conduit for endovascular aortic aneurysm repair (EVAR) is generally felt to result in higher morbidity and mortality, published literature is scarce. Our objective was to assess 30-day outcomes after elective EVAR with an open iliac conduit using a multi-institutional database. Patients who underwent elective EVAR (n = 14,339) for abdominal aortic aneurysm were identified from the American College of Surgeons National Surgical Quality Improvement Program 2005 to 2011 database. Univariable and multivariable logistic regression analyses were performed. An open iliac conduit was used in 231 patients (1.6%), and the remainder had femoral exposure or percutaneous EVAR. Women comprised 32% of patients with iliac conduits in contrast to 17% of those without iliac conduits. Patients with iliac conduits were older and had a lower body mass index. Univariable analysis showed patients with open iliac conduits had a higher incidence of postoperative pneumonia (3.0% vs 1.1%), ventilator dependence (4.8% vs 1.0%), renal failure (3.0% vs 0.7%), cardiac arrest or myocardial infarction (5.2% vs 1.1%), return to the operating room (9.1% vs 3.7%), major morbidity (16.0 vs 6.6%), and death (3.0% vs 0.9%). On multivariable analysis, the use of open iliac conduits was associated with higher risk of 30-day mortality (odds ratio, 2.7; 95% confidence interval, 1.2-6.0) and 30-day major morbidity (odds ratio, 2.3; 95% confidence interval, 1.6-3.3). Patients with open iliac conduits for EVAR are more likely to be female and have higher postoperative morbidity and mortality. For patients with complex iliac artery disease, conduits are a viable alternative after EVAR to be performed, albeit at an increased risk. These data do suggest the need for lower-profile grafts and other alternative strategies for navigating complex iliac artery disease. Copyright © 2015 Society for Vascular Surgery. All rights reserved.

  20. The effects of conduit length and acoustic velocity on conduit resonance: Implications for low-frequency events

    NASA Astrophysics Data System (ADS)

    Sturton, Susan; Neuberg, Jürgen

    2006-03-01

    Low-frequency seismic events at volcanoes are modelled as the seismic wavefield from a magma-filled conduit embedded in a solid country rock using a finite difference method. The effects of varying the conduit length and the impedance contrast between the magma and the country rock are examined, generating a range of possible signals. Short-windowed spectrograms are used to look at the time-frequency relationships within the events in detail, and some of the possible variations are identified using a series of schematic spectrograms. The numerical results are compared to examples of observed seismic data from Soufrière Hills Volcano, Montserrat. While the spectra of the observed events are often different to the spectra of the numerical results, the spectrograms have similar features and show that the low-frequency events from Montserrat are composed of discrete subevents.

  1. Manufacture of porous biodegradable polymer conduits by an extrusion process for guided tissue regeneration

    NASA Technical Reports Server (NTRS)

    Widmer, M. S.; Gupta, P. K.; Lu, L.; Meszlenyi, R. K.; Evans, G. R.; Brandt, K.; Savel, T.; Gurlek, A.; Patrick, C. W. Jr; Mikos, A. G.; hide

    1998-01-01

    We have fabricated porous, biodegradable tubular conduits for guided tissue regeneration using a combined solvent casting and extrusion technique. The biodegradable polymers used in this study were poly(DL-lactic-co-glycolic acid) (PLGA) and poly(L-lactic acid) (PLLA). A polymer/salt composite was first prepared by a solvent casting process. After drying, the composite was extruded to form a tubular construct. The salt particles in the construct were then leached out leaving a conduit with an open-pore structure. PLGA was studied as a model polymer to analyze the effects of salt weight fraction, salt particle size, and processing temperature on porosity and pore size of the extruded conduits. The porosity and pore size were found to increase with increasing salt weight fraction. Increasing the salt particle size increased the pore diameter but did not affect the porosity. High extrusion temperatures decreased the pore diameter without altering the porosity. Greater decrease in molecular weight was observed for conduits manufactured at higher temperatures. The mechanical properties of both PLGA and PLLA conduits were tested after degradation in vitro for up to 8 weeks. The modulus and failure strength of PLLA conduits were approximately 10 times higher than those of PLGA conduits. Failure strain was similar for both conduits. After degradation for 8 weeks, the molecular weights of the PLGA and PLLA conduits decreased to 38% and 43% of the initial values, respectively. However, both conduits maintained their shape and did not collapse. The PLGA also remained amorphous throughout the time course, while the crystallinity of PLLA increased from 5.2% to 11.5%. The potential of seeding the conduits with cells for transplantation or with biodegradable polymer microparticles for drug delivery was also tested with dyed microspheres. These porous tubular structures hold great promise for the regeneration of tissues which require tubular scaffolds such as peripheral nerve

  2. Decellularized aortic conduits: could their cryopreservation affect post-implantation outcomes? A morpho-functional study on porcine homografts.

    PubMed

    Gallo, Michele; Bonetti, Antonella; Poser, Helen; Naso, Filippo; Bottio, Tomaso; Bianco, Roberto; Paolin, Adolfo; Franci, Paolo; Busetto, Roberto; Frigo, Anna Chiara; Buratto, Edward; Spina, Michele; Marchini, Maurizio; Ortolani, Fulvia; Iop, Laura; Gerosa, Gino

    2016-11-01

    Decellularized porcine aortic valve conduits (AVCs) implanted in a Vietnamese Pig (VP) experimental animal model were matched against decellularized and then cryopreserved AVCs to assess the effect of cryopreservation on graft hemodynamic performance and propensity to in vivo repopulation by host's cells. VPs (n = 12) underwent right ventricular outflow tract substitution using AVC allografts and were studied for 15-month follow-up. VPs were randomized into two groups, receiving AVCs treated with decellularization alone (D; n = 6) or decellularization/cryopreservation (DC; n = 6), respectively. Serial echocardiography was carried out to follow up hemodynamic function. All explanted AVCs were processed for light and electron microscopy. No signs of dilatation, progressive stenosis, regurgitation, and macroscopic calcification were echocardiographically observed in both D and DC groups. Explanted D grafts exhibited near-normal features, whereas the presence of calcification, inflammatory infiltrates, and disarray of elastic lamellae occurred in some DC grafts. In the unaltered regions of AVCs from both groups, almost complete re-endothelialization was observed for both valve cusps and aorta walls. In addition, side-by-side repopulation by recipient's fibroblasts, myofibroblasts, and smooth muscle cells was paralleled by ongoing tissue remodeling, as revealed by the ultrastructural identification of typical canals of collagen fibrillogenesis and elastogenesis-related features. Incipient neo-vascularization and re-innervation of medial and adventitial tunicae of grafted aortic walls were also detected for both D and DC groups. Cryopreservation did not affect post-implantation AVC hemodynamic behavior and was topically propensive to cell repopulation and tissue renewal, although graft deterioration including calcification was present in several areas. Thus, these preliminary data provide essential information on feasibility of decellularization and

  3. Nuclear radiation actuated valve

    DOEpatents

    Christiansen, David W.; Schively, Dixon P.

    1985-01-01

    A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.

  4. Schockmed Valve: A Novel Surgical Option for Uncontrolled Glaucoma in Eyes with Poor Conjunctiva and Encircling Bands.

    PubMed

    Fleischman, David; Kim, Bryan

    2017-01-01

    Surgical management of elevated intraocular pressure (IOP) in an eye with scarred conjunctiva, an encircling band, and silicone oil has limited options. By combining the flow restrictor of the Ahmed Glaucoma Valve (New World Medical, Rancho Cucamonga, California) and the capsule of the encircling band as a conduit for aqueous flow, immediate pressure reduction could theoretically be achieved in eyes with limited conjunctival mobilization. This is a description of a surgical technique in a case of a patient with multiple ocular surgeries with uncontrolled multimechanism glaucoma despite using all available topical and oral glaucoma medications. A combination of the Ahmed valve with a modification of the Schocket shunt technique was used in this case of an encircling band and poor conjunctiva. At 10-month follow-up, the patient maintains controlled pressures on dorzolamide-timolol drops. The combined Ahmed-Schocket (or Schockmed) technique may be another surgical option for management of uncontrolled IOP in cases of scarred conjunctiva and encircling bands needing immediate pressure reduction. A novel surgical option for uncontrolled glaucoma in eyes with poor conjunctiva and encircling bands. How to cite this article: Fleischman D, Kim B. Schockmed Valve: A Novel Surgical Option for Uncontrolled Glaucoma in Eyes with Poor Conjunctiva and Encircling Bands. J Curr Glaucoma Pract 2017;11(3):120-124.

  5. High speed turbogenerator for power recovery from fluid flow within conduit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irvine, M. D.

    1985-11-26

    A high speed turbogenerator functionally combining, in one machine, an electrical generator and an expansion turbine. The electrical generator itself has a shaft supported on two bearings and the expansion turbine comprises an expander wheel overhung on the generator shaft and which rotates as a high pressure gas is let down in the expansion turbine to a lower pressure at a minimum predetermined flow rate and pressure drop. The shaft operates at speeds of about 6,000 rpm to 32,000 rpm, preferably at the higher end of such range, i.e. 20,000 to 24,000 rpm. The unit is sufficiently compact that amore » new use for the electrical generator is to modify the same such that the entire high speed turbogenerator is contained within the conduit carrying the gas to be let down in pressure and only electrical wires need be led through the conduit. The integrity of the conduit is thus retained to the extent possible and only a high pressure cable fitting extends through the conduit. In the preferred embodiment, the high speed turbogenerator is entirely fitted within a natural gas conduit in a gas distribution station, thereby achieving the pressure letdown and also obtaining useful electrical power.« less

  6. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    PubMed

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  7. JenaValve.

    PubMed

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  8. System and method for filling a plurality of isolated vehicle fluid circuits through a common fluid fill port

    DOEpatents

    Sullivan, Scott C; Fansler, Douglas

    2014-10-14

    A vehicle having multiple isolated fluid circuits configured to be filled through a common fill port includes a first fluid circuit disposed within the vehicle, the first fluid circuit having a first fill port, a second fluid circuit disposed within the vehicle, and a conduit defining a fluid passageway between the first fluid circuit and second fluid circuit, the conduit including a valve. The valve is configured such that the first and second fluid circuits are fluidly coupled via the passageway when the valve is open, and are fluidly isolated when the valve is closed.

  9. Fast valve

    DOEpatents

    Van Dyke, W.J.

    1992-04-07

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing. 4 figs.

  10. Fast valve

    DOEpatents

    Van Dyke, William J.

    1992-01-01

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing.

  11. Bubble suspension rheology and implications for conduit flow

    NASA Astrophysics Data System (ADS)

    Llewellin, E. W.; Manga, M.

    2005-05-01

    Bubbles are ubiquitous in magma during eruption and influence the rheology of the suspension. Despite this, bubble-suspension rheology is routinely ignored in conduit-flow and eruption models, potentially impairing accuracy and resulting in the loss of important phenomenological richness. The omission is due, in part, to a historical confusion in the literature concerning the effect of bubbles on the rheology of a liquid. This confusion has now been largely resolved and recently published studies have identified two viscous regimes: in regime 1, the viscosity of the two-phase (magma-gas) suspension increases as gas volume fraction ϕ increases; in regime 2, the viscosity of the suspension decreases as ϕ increases. The viscous regime for a deforming bubble suspension can be determined by calculating two dimensionless numbers, the capillary number Ca and the dynamic capillary number Cd. We provide a didactic explanation of how to include the effect of bubble-suspension rheology in continuum, conduit-flow models. Bubble-suspension rheology is reviewed and a practical rheological model is presented, followed by an algorithmic, step-by-step guide to including the rheological model in conduit-flow models. Preliminary results from conduit-flow models which have implemented the model presented are discussed and it is concluded that the effect of bubbles on magma rheology may be important in nature and results in a decrease of at least 800 m in calculated fragmentation-depth and an increase of between 40% and 250% in calculated eruption-rate compared with the assumption of Newtonian rheology.

  12. Treatment of right ventricle to pulmonary artery conduit stenosis in infants with hypoplastic left heart syndrome.

    PubMed

    Münsterer, Andrea; Kasnar-Samprec, Jelena; Hörer, Jürgen; Cleuziou, Julie; Eicken, Andreas; Malcic, Ivan; Lange, Rüdiger; Schreiber, Christian

    2013-09-01

    To determine the incidence of right ventricle-to-pulmonary artery (RV-PA) conduit stenosis after the Norwood I operation in patients with hypoplastic left heart syndrome (HLHS), and to determine whether the treatment strategy of RV-PA conduit stenosis has an influence on interstage and overall survival. Ninety-six patients had a Norwood operation with RV-PA conduit between 2002 and 2011. Details of reoperations/interventions due to conduit obstruction prior to bidirectional superior cavopulmonary anastomosis (BSCPA) were collected. Overall pre-BSCPA mortality was 17%, early mortality after Norwood, 6%. Early angiography was performed in 34 patients due to desaturation at a median of 8 days after the Norwood operation. Fifteen patients (16%) were diagnosed with RV-PA conduit stenosis that required treatment. The location of the conduit stenosis was significantly different in the patients with non-ringed (proximal) and the patients with ring-enforced conduit (distal), P = 0.004. In 6 patients, a surgical revision of the conduit was performed; 3 of them died prior to BSCPA. Another 6 patients had a stent implantation and 3 were treated with balloon dilatation followed by a BSCPA in the subsequent 2 weeks. All patients who were treated interventionally for RV-PA conduit obstruction had a successful BSCPA. Patients who received a surgical RV-PA conduit revision had a significantly higher interstage (P = 0.044) and overall mortality (P = 0.011) than those who received a stent or balloon dilatation of the stenosis followed by an early BSCPA. RV-PA conduit obstruction after Norwood I procedure in patients with HLHS can be safely and effectively treated by stent implantation, balloon dilatation and early BSCPA. Surgical revision of the RV-PA conduit can be reserved for patients in whom an interventional approach fails, and an early BSCPA is not an option.

  13. Nitrous acid pretreatment of tendon xenografts cross-linked with glutaraldehyde and sterilized with gamma irradiation.

    PubMed

    Johnson, K A; Rogers, G J; Roe, S C; Howlett, C R; Clayton, M K; Milthorpe, B K; Schindhelm, K

    1999-06-01

    Collagenous xenografts made from kangaroo tail tendon cross-linked with glutaraldehyde have a potential application in the reconstruction of massive digital tendon deficits. However, a limitation to the clinical use of these xenografts has been the optimization of collagen cross-linking, and subsequent bio-incorporation and retention of mechanical properties following implantation. The purpose of this study was to evaluate the effect of nitrous acid on modulating the biologic and mechanical properties of tendon xenografts cross-linked with glutaraldehyde. Tendon xenografts were pretreated with 0.1 or 0.01 M nitrous acid solution, prior to cross-linking in 2% glutaraldehyde and sterilization by gamma irradiation. Xenografts were implanted intramuscularly in rabbits to examine biocompatability, and also used to repair ovine digital extensor tendon deficits to evaluate functional incorporation. Histologically, intramuscularly implanted nitrous acid pretreated xenografts in rabbits had a greater degree of diffuse cellular infiltration into interstitial splits in the graft than controls after 12 weeks. Xenografts implanted in an ovine extensor tendon deficit were evaluated after 26 and 52 weeks. Rate of failure of tenorrhaphies between host tendon and xenografts overall (15/21) was significantly greater (P < 0.05) than for autografts (1/21), suggesting that the holding power of sutures in xenografts was inferior to that obtained in autografts. Tensile failure stress of midsections of both nitrous acid pretreated and control xenografts was about 100 MPa prior to implantation (time zero). After 26 and 52 weeks, failure stress of both types of xenografts was significantly less than at time zero (P < 0.05). At 52 weeks, failure stress of nitrous acid pretreated xenografts (47.4 +/- 3.1 MPa) was significantly less than control xenografts (63.7 +/- 5.4 MPa); (P < 0.05). However, nitrous acid pretreated xenografts were similar to control xenografts in failure load (357 +/- 29

  14. Development of a comprehensive inventory management system for underground fiber optic conduits.

    DOT National Transportation Integrated Search

    2013-03-01

    Major State Departments of Transportation operate and maintain networks of thousands of miles of conduits, many : carrying fiber optic cables that are vital to State communication systems. These conduits are located alongside or : across highways and...

  15. Stemless Ball Valve

    NASA Technical Reports Server (NTRS)

    Burgess, Robert K.; Yakos, David; Walthall, Bryan

    2012-01-01

    This invention utilizes a new method of opening and closing a ball valve. Instead of rotating the ball with a perpendicular stem (as is the case with standard ball valves), the ball is rotated around a fixed axis by two guide pins. This innovation eliminates the leak point that is present in all standard ball valves due to the penetration of an actuation stem through the valve body. The VOST (Venturi Off-Set-Technology) valve has been developed for commercial applications. The standard version of the valve consists of an off-set venturi flow path through the valve. This path is split at the narrowest portion of the venturi, allowing the section upstream from the venturi to be rotated. As this rotation takes place, the venturi becomes restricted as one face rotates with respect to the other, eventually closing off the flow path. A spring-loaded seal made of resilient material is embedded in the upstream face of the valve, making a leak-proof seal between the faces; thus a valve is formed. The spring-loaded lip seal is the only seal that can provide a class six, or bubble-tight, seal against the opposite face of the valve. Tearing action of the seal by high-velocity gas on this early design required relocation of the seal to the downstream face of the valve. In the stemless embodiment of this valve, inner and outer magnetic cartridges are employed to transfer mechanical torque from the outside of the valve to the inside without the use of a stem. This eliminates the leak path caused by the valve stems in standard valves because the stems penetrate through the bodies of these valves.

  16. Volcanic conduit failure as a trigger to magma fragmentation

    NASA Astrophysics Data System (ADS)

    Lavallée, Y.; Benson, P. M.; Heap, M. J.; Flaws, A.; Hess, K.-U.; Dingwell, D. B.

    2012-01-01

    In the assessment of volcanic risk, it is often assumed that magma ascending at a slow rate will erupt effusively, whereas magma ascending at fast rate will lead to an explosive eruption. Mechanistically viewed, this assessment is supported by the notion that the viscoelastic nature of magma (i.e., the ability of magma to relax at an applied strain rate), linked via the gradient of flow pressure (related to discharge rate), controls the eruption style. In such an analysis, the physical interactions between the magma and the conduit wall are commonly, to a first order, neglected. Yet, during ascent, magma must force its way through the volcanic edifice/structure, whose presence and form may greatly affect the stress field through which the magma is trying to ascend. Here, we demonstrate that fracturing of the conduit wall via flow pressure releases an elastic shock resulting in fracturing of the viscous magma itself. We find that magma fragmentation occurred at strain rates seven orders of magnitude slower than theoretically anticipated from the applied axial strain rate. Our conclusion, that the discharge rate cannot provide a reliable indication of ascending magma rheology without knowledge of conduit wall stability, has important ramifications for volcanic hazard assessment. New numerical simulations are now needed in order to integrate magma/conduit interaction into eruption models.

  17. Refrigeration arrangement and methods for reducing charge migration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litch, Andrew D.; Wu, Guolian

    A refrigerator appliance including a refrigerant circuit between a condenser, an evaporator, and a compressor that includes two conduits and pressure reducing devices arranged in parallel between the evaporator and the condenser. The appliance also includes a valve system to direct refrigerant through one, both or none of the conduits and pressure reducing devices, and a heat exchanging member in thermal contact with either one pressure reducing device, or one conduit between the pressure reducing device and the valve system.

  18. Establishing prostate cancer patient derived xenografts: lessons learned from older studies.

    PubMed

    Russell, Pamela J; Russell, Peter; Rudduck, Christina; Tse, Brian W C; Williams, Elizabeth D; Raghavan, Derek

    2015-05-01

    Understanding the progression of prostate cancer to androgen-independence/castrate resistance and development of preclinical testing models are important for developing new prostate cancer therapies. This report describes studies performed 30 years ago, which demonstrate utility and shortfalls of xenografting to preclinical modeling. We subcutaneously implanted male nude mice with small prostate cancer fragments from transurethral resection of the prostate (TURP) from 29 patients. Successful xenografts were passaged into new host mice. They were characterized using histology, immunohistochemistry for marker expression, flow cytometry for ploidy status, and in some cases by electron microscopy and response to testosterone. Two xenografts were karyotyped by G-banding. Tissues from 3/29 donors (10%) gave rise to xenografts that were successfully serially passaged in vivo. Two, (UCRU-PR-1, which subsequently was replaced by a mouse fibrosarcoma, and UCRU-PR-2, which combined epithelial and neuroendocrine features) have been described. UCRU-PR-4 line was a poorly differentiated prostatic adenocarcinoma derived from a patient who had undergone estrogen therapy and bilateral castration after his cancer relapsed. Histologically, this comprised diffusely infiltrating small acinar cell carcinoma with more solid aggregates of poorly differentiated adenocarcinoma. The xenografted line showed histology consistent with a poorly differentiated adenocarcinoma and stained positively for prostatic acid phosphatase (PAcP), epithelial membrane antigen (EMA) and the cytokeratin cocktail, CAM5.2, with weak staining for prostate specific antigen (PSA). The line failed to grow in female nude mice. Castration of three male nude mice after xenograft establishment resulted in cessation of growth in one, growth regression in another and transient growth in another, suggesting that some cells had retained androgen sensitivity. The karyotype (from passage 1) was 43-46, XY, dic(1;12)(p11;p11

  19. Establishing Prostate Cancer Patient Derived Xenografts: Lessons Learned From Older Studies

    PubMed Central

    Russell, Pamela J; Russell, Peter; Rudduck, Christina; Tse, Brian W-C; Williams, Elizabeth D; Raghavan, Derek

    2015-01-01

    Background Understanding the progression of prostate cancer to androgen-independence/castrate resistance and development of preclinical testing models are important for developing new prostate cancer therapies. This report describes studies performed 30 years ago, which demonstrate utility and shortfalls of xenografting to preclinical modeling. Methods We subcutaneously implanted male nude mice with small prostate cancer fragments from transurethral resection of the prostate (TURP) from 29 patients. Successful xenografts were passaged into new host mice. They were characterized using histology, immunohistochemistry for marker expression, flow cytometry for ploidy status, and in some cases by electron microscopy and response to testosterone. Two xenografts were karyotyped by G-banding. Results Tissues from 3/29 donors (10%) gave rise to xenografts that were successfully serially passaged in vivo. Two, (UCRU-PR-1, which subsequently was replaced by a mouse fibrosarcoma, and UCRU-PR-2, which combined epithelial and neuroendocrine features) have been described. UCRU-PR-4 line was a poorly differentiated prostatic adenocarcinoma derived from a patient who had undergone estrogen therapy and bilateral castration after his cancer relapsed. Histologically, this comprised diffusely infiltrating small acinar cell carcinoma with more solid aggregates of poorly differentiated adenocarcinoma. The xenografted line showed histology consistent with a poorly differentiated adenocarcinoma and stained positively for prostatic acid phosphatase (PAcP), epithelial membrane antigen (EMA) and the cytokeratin cocktail, CAM5.2, with weak staining for prostate specific antigen (PSA). The line failed to grow in female nude mice. Castration of three male nude mice after xenograft establishment resulted in cessation of growth in one, growth regression in another and transient growth in another, suggesting that some cells had retained androgen sensitivity. The karyotype (from passage 1) was 43

  20. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    PubMed

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Stability of volcanic conduits: insights from magma ascent modelling and possible consequences on eruptive dynamics

    NASA Astrophysics Data System (ADS)

    Aravena, Alvaro; de'Michieli Vitturi, Mattia; Cioni, Raffaello; Neri, Augusto

    2017-04-01

    Geological evidences of changes in volcanic conduit geometry (i.e. erosive processes) are common in the volcanic record, as revealed by the occurrence of lithic fragments in most pyroclastic deposits. However, the controlling factors of conduit enlargement mechanisms are still partially unclear, as well as the influence of conduit geometry in the eruptive dynamics. Despite physical models have been systematically used for studying volcanic conduits, their mechanical stability has been poorly addressed. In order to study the mechanical stability of volcanic conduits during explosive eruptions, we present a 1D steady-state model which considers the main processes experimented by ascending magmas, such as crystallization, drag forces, fragmentation, outgassing and degassing; and the application of the Mogi-Coulomb collapse criterion, using a set of constitutive equations for studying typical cases of rhyolitic and trachytic explosive volcanism. From our results emerge that conduit stability is mainly controlled by magma rheology and conduit dimensions. Indeed, in order to be stable, feeding conduits of rhyolitic eruptions need larger radii respect to their trachytic counterparts, which is manifested in the higher eruption rates usually observed in rhyolitic explosive eruptions, as confirmed by a small compilation of global data. Additionally, for both magma compositions, we estimated a minimum magma flux for developing stable conduits (˜3ṡ106 kg/s for trachytic magmas and ˜8ṡ107 kg/s for rhyolitic magmas), which is consistent with the unsteady character commonly observed in low-mass flux events (e.g. sub-Plinian eruptions), which would be produced by episodic collapse events of the volcanic conduit, opposite to the mainly stationary high-mass flux events (e.g. Plinian eruptions), characterized by stable conduits. For a given magma composition, a minimum radius for reaching stable conditions can be computed, as a function of inlet overpressure and water content

  2. Modelling the Effects of Magma Properties, Pressure and Conduit Dimensions on the Seismic Signature

    NASA Astrophysics Data System (ADS)

    Sturton, S.; Neuberg, J.

    2002-12-01

    A finite-difference scheme is used to model the seismic radiation pattern for a fluid filled conduit surrounded by a solid medium. Seismic waves travel slower than the acoustic velocity inside the conduit and the propagation velocity is frequency dependent. At the ends of the conduit the waves are partly reflected back along the conduit and also leak into the solid medium. The seismometer signal obtained is therefore composed of a series of events released from the ends of the conduit. Each signal can be characterised by the repeat time of the events and the dispersion seen within each event. These characteristics are dependent on the seismic parameters and the conduit dimensions. For a gas-charged magma, increasing the pressure with depth reduces the volume of gas exsolved, thereby increasing the seismic velocity lower in the conduit. From the volume of gas exsolved, profiles of seismic parameters within the conduit and their evolution with time can be obtained. The differences between a varying velocity with depth and a constant velocity with depth are seen in the synthetic seismograms and spectrograms. At Soufriere Hills Volcano, Montserrat, single hybrid events merge into tremor and occasionally gliding lines are observed in the spectra indicating changes in the seismic parameters with time or varying triggering rates of single events. The synthetic seismograms are compared to the observational data and used to constrain the magnitude of pressure changes necessary to produce the gliding lines. Further constraints are obtained from the dispersion patterns in both the synthetic seismograms and the observed data.

  3. Ash production by attrition in volcanic conduits and plumes.

    PubMed

    Jones, T J; Russell, J K

    2017-07-17

    Tephra deposits result from explosive volcanic eruption and serve as indirect probes into fragmentation processes operating in subsurface volcanic conduits. Primary magmatic fragmentation creates a population of pyroclasts through volatile-driven decompression during conduit ascent. In this study, we explore the role that secondary fragmentation, specifically attrition, has in transforming primary pyroclasts upon transport in volcanic conduits and plumes. We utilize total grain size distributions from a suite of natural and experimentally produced tephra to show that attrition is likely to occur in all explosive volcanic eruptions. Our experimental results indicate that fine ash production and surface area generation is fast (<15 min) thereby rapidly raising the fractal dimension of tephra deposits. Furthermore, a new metric, the Entropy of Information, is introduced to quantify the degree of attrition (secondary fragmentation) from grain size data. Attrition elevates fine ash production which, in turn, has consequences for eruption column stability, tephra dispersal, aggregation, volcanic lightening generation, and has concomitant effects on aviation safety and Earth's climate.

  4. Excess flow shutoff valve

    DOEpatents

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  5. Biodegradable Bisvinyl Sulfonemethyl-crosslinked Gelatin Conduit Promotes Regeneration after Peripheral Nerve Injury in Adult Rats.

    PubMed

    Ko, Chien-Hsin; Shie, Ming-You; Lin, Jia-Horng; Chen, Yi-Wen; Yao, Chun-Hsu; Chen, Yueh-Sheng

    2017-12-13

    In our previous study, we found that gelatin-based materials exhibit good conductivity and are non-cytotoxic. In this study, gelatin was cross-linked with bisvinyl sulfonemethyl (BVSM) to fabricate a biodegradable conduit for peripheral nerve repair. First, BVSM on the prepared conduit was characterized to determine its mechanical properties and contact angle. The maximum tensile strength and water contact angle of the gelatin-BVSM conduits were 23 ± 4.8 MPa and 74.7 ± 9°, which provided sufficient mechanical strength to resist muscular contraction; additionally, the surface was hydrophilic. Cytotoxicity and apoptosis assays using Schwann cells demonstrated that the gelatin-BVSM conduits are non-cytotoxic. Next, we examined the neuronal electrophysiology, animal behavior, neuronal connectivity, macrophage infiltration, calcitonin gene-related peptide localization and expression, as well as the expression levels of nerve regeneration-related proteins. The number of fluorogold-labelled cells and histological analysis of the gelatin-BVSM nerve conduits was similar to that observed with the clinical use of silicone rubber conduits after 8 weeks of repair. Therefore, our results demonstrate that gelatin-BVSM conduits are promising substrates for application as bioengineered grafts for nerve tissue regeneration.

  6. Visualization of conduit-matrix conductivity differences in a karst aquifer using time-lapse electrical resistivity

    NASA Astrophysics Data System (ADS)

    Meyerhoff, Steven B.; Karaoulis, Marios; Fiebig, Florian; Maxwell, Reed M.; Revil, André; Martin, Jonathan B.; Graham, Wendy D.

    2012-12-01

    In the karstic upper Floridan aquifer, surface water flows into conduits of the groundwater system and may exchange with water in the aquifer matrix. This exchange has been hypothesized to occur based on differences in discharge at the Santa Fe River Sink-Rise system, north central Florida, but has yet to be visualized using any geophysical techniques. Using electrical resistivity tomography, we conducted a time-lapse study at two locations with mapped conduits connecting the Santa Fe River Sink to the Santa Fe River Rise to study changes of electrical conductivity during times of varying discharge over a six-week period. Our results show conductivity differences between matrix, conduit changes in resistivity occurring through time at the locations of mapped karst conduits, and changes in electrical conductivity during rainfall infiltration. These observations provide insight into time scales and matrix conduit conductivity differences, illustrating how surface water flow recharged to conduits may flow in a groundwater system in a karst aquifer.

  7. Replacement of the aortic root with a composite valve-graft conduit: risk factor analysis in 246 consecutive patients.

    PubMed

    Woldendorp, Kei; Starra, Eric; Seco, Michael; Hendel, P Nicholas; Jeremy, Richmond W; Wilson, Michael K; Vallely, Michael P; Bannon, Paul G

    2014-12-01

    Composite valve-graft (CVG) replacement of the aortic root is a well-studied and recognised treatment for various aortic root conditions, including valvular disease with associated aortopathy. There have been few previous studies of the procedure in large numbers in an Australian setting. From January 2006 to June 2013, 246 successive patients underwent CVG root replacements at our institution. Mean age was 56.8 years, 85.4% were male, and 87 had evidence of bicuspid aortic valve. Indications for operation included ascending aortic aneurysm in 222 patients, annuloaortic ectasia in 67 patients, and aortic dissection in 38 patients. The overall unit 30-day mortality was 5.7%, including: elective 30-day mortality of 2.2%, and emergent 30-day mortality of 17.2%. Statistically significant multivariate predictors of 30-day mortality were: acute aortic dissection (OR=20.07), peripheral vascular disease (OR=11.17), new ventricular tachycardia (OR=30.17), re-operation for bleeding (OR=14.42), concomitant mitral stenosis (OR=68.30), and cerebrovascular accident (OR=144.85). Low postoperative mortality in our series matches closely with results from similar sized international studies, demonstrating that this procedure can be performed with low risk in centres with sufficient experience in the operative procedure. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  8. Absence of posterior tricuspid valve leaflet and valve reconstruction

    PubMed Central

    Komoda, Takeshi; Stamm, Christof; Fleck, Eckart; Hetzer, Roland

    2012-01-01

    We report a rare case of the absence of a posterior tricuspid valve leaflet. A male patient, aged 46, suffering from severe tricuspid valve regurgitation (TR) of unknown aetiology and atrial septal aneurysm was referred to our hospital for surgery. On surgical inspection, the posterior tricuspid valve leaflet and its subvalvular apparatus were completely absent and only the valve annulus was seen in the corresponding position. The anterior and septal leaflets were normal. We successfully reconstructed the tricuspid valve as follows: the head of an anterior papillary muscle was approximated to the ventricular septum (Sebening stitch). After the approximation of the centre of the tricuspid annulus of the anterior leaflet to the tricuspid annulus on the opposite side, a sizer of 29 mm in diameter was easily passed through the anterior orifice. The posterior orifice was closed with running sutures (posterior annulorrhaphy after Hetzer). Before these procedures, we attempted to reconstruct the tricuspid valve with a posterior annulorrhaphy alone; however, valve competence was insufficient. A Sebening stitch was necessary to improve the valve competence. Echocardiography showed TR grade 1 at the patient's discharge from hospital and TR grade 1 to 2 at the follow-up, 10 months after the operation. PMID:22419794

  9. Effects of dynamically variable saturation and matrix-conduit coupling of flow in karst aquifers

    USGS Publications Warehouse

    Reimann, T.; Geyer, T.; Shoemaker, W.B.; Liedl, R.; Sauter, M.

    2011-01-01

    Well-developed karst aquifers consist of highly conductive conduits and a relatively low permeability fractured and/or porous rock matrix and therefore behave as a dual-hydraulic system. Groundwater flow within highly permeable strata is rapid and transient and depends on local flow conditions, i.e., pressurized or nonpressurized flow. The characterization of karst aquifers is a necessary and challenging task because information about hydraulic and spatial conduit properties is poorly defined or unknown. To investigate karst aquifers, hydraulic stresses such as large recharge events can be simulated with hybrid (coupled discrete continuum) models. Since existing hybrid models are simplifications of the system dynamics, a new karst model (ModBraC) is presented that accounts for unsteady and nonuniform discrete flow in variably saturated conduits employing the Saint-Venant equations. Model performance tests indicate that ModBraC is able to simulate (1) unsteady and nonuniform flow in variably filled conduits, (2) draining and refilling of conduits with stable transition between free-surface and pressurized flow and correct storage representation, (3) water exchange between matrix and variably filled conduits, and (4) discharge routing through branched and intermeshed conduit networks. Subsequently, ModBraC is applied to an idealized catchment to investigate the significance of free-surface flow representation. A parameter study is conducted with two different initial conditions: (1) pressurized flow and (2) free-surface flow. If free-surface flow prevails, the systems is characterized by (1) a time lag for signal transmission, (2) a typical spring discharge pattern representing the transition from pressurized to free-surface flow, and (3) a reduced conduit-matrix interaction during free-surface flow. Copyright 2011 by the American Geophysical Union.

  10. Xenograft model for therapeutic drug testing in recurrent respiratory papillomatosis.

    PubMed

    Ahn, Julie; Bishop, Justin A; Akpeng, Belinda; Pai, Sara I; Best, Simon R A

    2015-02-01

    Identifying effective treatment for papillomatosis is limited by a lack of animal models, and there is currently no preclinical model for testing potential therapeutic agents. We hypothesized that xenografting of papilloma may facilitate in vivo drug testing to identify novel treatment options. A biopsy of fresh tracheal papilloma was xenografted into a NOD-scid-IL2Rgamma(null) (NSG) mouse. The xenograft began growing after 5 weeks and was serially passaged over multiple generations. Each generation showed a consistent log-growth pattern, and in all xenografts, the presence of the human papillomavirus (HPV) genome was confirmed by polymerase chain reaction (PCR). Histopathologic analysis demonstrated that the squamous architecture of the original papilloma was maintained in each generation. In vivo drug testing with bevacizumab (5 mg/kg i.p. twice weekly for 3 weeks) showed a dramatic therapeutic response compared to saline control. We report here the first successful case of serial xenografting of a tracheal papilloma in vivo with a therapeutic response observed with drug testing. In severely immunocompromised mice, the HPV genome and squamous differentiation of the papilloma can be maintained for multiple generations. This is a feasible approach to identify therapeutic agents in the treatment of recurrent respiratory papillomatosis. © The Author(s) 2014.

  11. [Percutaneously implantable aortic valve: the JenaValve concept evolution].

    PubMed

    Figulla, Hans R; Ferrari, Markus

    2006-10-01

    Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.

  12. 30 CFR 18.39 - Hose conduit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hose conduit. 18.39 Section 18.39 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements...

  13. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    PubMed

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  14. Early Outcomes for Valve-in-valve Transcatheter Aortic Valve Replacement in Degenerative Freestyle Bioprostheses.

    PubMed

    Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William

    2017-11-20

    Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  16. Ball valve extractor

    DOEpatents

    Herndon, Charles; Brown, Roger A.

    2002-01-01

    An apparatus and process for removing a ball valve is provided. The ball valve removal tool provides a handle sliding along the length of a shaft. One end of the shaft is secured within an interior cavity of a ball valve while the opposite end of the shaft defines a stop member. By providing a manual sliding force to the handle, the handle impacts the stop member and transmits the force to the ball valve. The direction of the force is along the shaft of the removal tool and disengages the ball valve from the ball valve housing.

  17. Bellows sealed plug valve

    DOEpatents

    Dukas, Jr., Stephen J.

    1990-01-01

    A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.

  18. Check valve installation in pilot operated relief valve prevents reverse pressurization

    NASA Technical Reports Server (NTRS)

    Oswalt, L.

    1966-01-01

    Two check valves prevent reverse flow through pilot-operated relief valves of differential area piston design. Title valves control pressure flow to ensure that the piston dome pressure is always at least as great as the main relief valve discharge pressure.

  19. Serological aspects of rat tumour xenograft growth in athymic nude mice.

    PubMed Central

    Pimm, M. V.; Baldwin, R. W.

    1979-01-01

    The serum of athymic nude mice bearing rat tumour xenografts has been examined for tumour-specific antigen. With a sarcoma and a hepatoma, tumour-specific antigen expression continued in xenograft growths, and sera of tumour-bearing mice contained free antigen, assayed by its ability to neutralise reactivity of tumour-immune rat sera against tumour target cells in an indirect membrane-immunofluorescence test. In contrast, no anti-rat antibody was detectable in sera of mice bearing the xenografts, or rejecting cells injected in admixture with BCG. PMID:373782

  20. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    PubMed Central

    Abulon, Dina Joy; Charles, Martin; Charles, Daniel E

    2015-01-01

    Purpose To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP), fluid leakage, and vitreous incarceration during simulated vitrectomy. Methods Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes. Results In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005), and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05) and 27-gauge (P<0.05) non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas. Conclusion Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy. PMID:26445520

  1. Microfluidic sieve valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  2. Peripheral nerve regeneration with conduits: use of vein tubes

    PubMed Central

    Sabongi, Rodrigo Guerra; Fernandes, Marcela; dos Santos, João Baptista Gomes

    2015-01-01

    Treatment of peripheral nerve injuries remains a challenge to modern medicine due to the complexity of the neurobiological nerve regenerating process. There is a greater challenge when the transected nerve ends are not amenable to primary end-to-end tensionless neurorraphy. When facing a segmental nerve defect, great effort has been made to develop an alternative to the autologous nerve graft in order to circumvent morbidity at donor site, such as neuroma formation, scarring and permanent loss of function. Tubolization techniques have been developed to bridge nerve gaps and have been extensively studied in numerous experimental and clinical trials. The use of a conduit intends to act as a vehicle for moderation and modulation of the cellular and molecular ambience for nerve regeneration. Among several conduits, vein tubes were validated for clinical application with improving outcomes over the years. This article aims to address the investigation and treatment of segmental nerve injury and draw the current panorama on the use of vein tubes as an autogenous nerve conduit. PMID:26170802

  3. Peripheral nerve regeneration with conduits: use of vein tubes.

    PubMed

    Sabongi, Rodrigo Guerra; Fernandes, Marcela; Dos Santos, João Baptista Gomes

    2015-04-01

    Treatment of peripheral nerve injuries remains a challenge to modern medicine due to the complexity of the neurobiological nerve regenerating process. There is a greater challenge when the transected nerve ends are not amenable to primary end-to-end tensionless neurorraphy. When facing a segmental nerve defect, great effort has been made to develop an alternative to the autologous nerve graft in order to circumvent morbidity at donor site, such as neuroma formation, scarring and permanent loss of function. Tubolization techniques have been developed to bridge nerve gaps and have been extensively studied in numerous experimental and clinical trials. The use of a conduit intends to act as a vehicle for moderation and modulation of the cellular and molecular ambience for nerve regeneration. Among several conduits, vein tubes were validated for clinical application with improving outcomes over the years. This article aims to address the investigation and treatment of segmental nerve injury and draw the current panorama on the use of vein tubes as an autogenous nerve conduit.

  4. Preoperative imaging and prediction of oesophageal conduit necrosis after oesophagectomy for cancer.

    PubMed

    Lainas, P; Fuks, D; Gaujoux, S; Machroub, Z; Fregeville, A; Perniceni, T; Mal, F; Dousset, B; Gayet, B

    2017-09-01

    Oesophageal conduit necrosis following oesophagectomy is a rare but life-threatening complication. The present study aimed to assess the impact of coeliac axis stenosis on outcomes after oesophagectomy for cancer. The study included consecutive patients who had an Ivor Lewis procedure with curative intent for middle- and lower-third oesophageal cancer at two tertiary referral centres. All patients underwent preoperative multidetector CT with arterial phase to detect coeliac axis stenosis. The coeliac artery was classified as normal, with extrinsic stenosis due to a median arcuate ligament or with intrinsic stenosis caused by atherosclerosis. Some 481 patients underwent an Ivor Lewis procedure. Of these, ten (2·1 per cent) developed oesophageal conduit necrosis after surgery. Coeliac artery evaluation revealed a completely normal artery in 431 patients (91·5 per cent) in the group without conduit necrosis and in one (10 per cent) with necrosis (P < 0·001). Extrinsic stenosis of the coeliac artery due to a median arcuate ligament was found in two patients (0·4 per cent) without conduit necrosis and five (50 per cent) with necrosis (P < 0·001). Intrinsic stenosis of the coeliac artery was found in 11 (2·3 per cent) and eight (80 per cent) patients respectively (P < 0·001). Eight patients without (1·7 per cent) and five (50 per cent) with conduit necrosis had a single and thin left gastric artery (P < 0·001). This study suggests that oesophageal conduit necrosis after oesophagectomy for cancer may be due to pre-existing coeliac axis stenosis. © 2017 BJS Society Ltd Published by John Wiley & Sons Ltd.

  5. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    PubMed

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Problem: Heart Valve Stenosis

    MedlinePlus

    ... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...

  7. The grain-size distribution of pyroclasts: Primary fragmentation, conduit sorting or abrasion?

    NASA Astrophysics Data System (ADS)

    Kueppers, U.; Schauroth, J.; Taddeucci, J.

    2013-12-01

    Explosive volcanic eruptions expel a mixture of pyroclasts and lithics. Pyroclasts, fragments of the juvenile magma, record the state of the magma at fragmentation in terms of porosity and crystallinity. The grain size distribution of pyroclasts is generally considered to be a direct consequence of the conditions at magma fragmentation that is mainly driven by gas overpressure in bubbles, high shear rates, contact with external water or a combination of these factors. Stress exerted by any of these processes will lead to brittle fragmentation by overcoming the magma's relaxation timescale. As a consequence, most pyroclasts exhibit angular shapes. Upon magma fragmentation, the gas pyroclast mixture is accelerated upwards and eventually ejected from the vent. The total grain size distribution deposited is a function of fragmentation conditions and transport related sorting. Porous pyroclasts are very susceptible to abrasion by particle-particle or particle-conduit wall interaction. Accordingly, pyroclastic fall deposits with angular clasts should proof a low particle abrasion upon contact to other surfaces. In an attempt to constrain the degree of particle interaction during conduit flow, monomodal batches of washed pyroclasts have been accelerated upwards by rapid decompression and subsequently investigated for their grain size distribution. In our set-up, we used a vertical cylindrical tube without surface roughness as conduit. We varied grain size (0.125-0.25; 0.5-1; 1-2 mm), porosity (0; 10; 30 %), gas-particle ratio (10 and 40%), conduit length (10 and 28 cm) and conduit diameter (2.5 and 6 cm). All ejected particles were collected after settling at the base of a 3.3 m high tank and sieved at one sieve size below starting size (half-Φ). Grain size reduction showed a positive correlation with starting grain size, porosity and overpressure at the vent. Although milling in a volcanic conduit may take place, porous pyroclasts are very likely to be a primary product

  8. High temperature lined conduits, elbows and tees

    DOEpatents

    De Feo, Angelo; Drewniany, Edward

    1982-01-01

    A high temperature lined conduit comprising, a liner, a flexible insulating refractory blanket around and in contact with the liner, a pipe member around the blanket and spaced therefrom, and castable rigid refractory material between the pipe member and the blanket. Anchors are connected to the inside diameter of the pipe and extend into the castable material. The liner includes male and female slip joint ends for permitting thermal expansion of the liner with respect to the castable material and the pipe member. Elbows and tees of the lined conduit comprise an elbow liner wrapped with insulating refractory blanket material around which is disposed a spaced elbow pipe member with castable refractory material between the blanket material and the elbow pipe member. A reinforcing band is connected to the elbow liner at an intermediate location thereon from which extend a plurality of hollow tubes or pins which extend into the castable material to anchor the lined elbow and permit thermal expansion. A method of fabricating the high temperature lined conduit, elbows and tees is also disclosed which utilizes a polyethylene layer over the refractory blanket after it has been compressed to maintain the refractory blanket in a compressed condition until the castable material is in place. Hot gases are then directed through the interior of the liner for evaporating the polyethylene and setting the castable material which permits the compressed blanket to come into close contact with the castable material.

  9. Vacuum breaker valve assembly

    DOEpatents

    Thompson, J.L.; Upton, H.A.

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening. 1 fig.

  10. Vacuum breaker valve assembly

    DOEpatents

    Thompson, Jeffrey L.; Upton, Hubert Allen

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening.

  11. Improved axonal regeneration of transected spinal cord mediated by multichannel collagen conduits functionalized with neurotrophin-3 gene.

    PubMed

    Yao, L; Daly, W; Newland, B; Yao, S; Wang, W; Chen, B K K; Madigan, N; Windebank, A; Pandit, A

    2013-12-01

    Functionalized biomaterial scaffolds targeted at improving axonal regeneration by enhancing guided axonal growth provide a promising approach for the repair of spinal cord injury. Collagen neural conduits provide structural guidance for neural tissue regeneration, and in this study it is shown that these conduits can also act as a reservoir for sustained gene delivery. Either a G-luciferase marker gene or a neurotrophin-3-encoding gene, complexed to a non-viral, cyclized, PEGylated transfection vector, was loaded within a multichannel collagen conduit. The complexed genes were then released in a controlled fashion using a dual release system both in vitro and in vivo. For evaluation of their biological performance, the loaded conduits were implanted into the completely transected rat thoracic spinal cord (T8-T10). Aligned axon regeneration through the channels of conduits was observed one month post-surgery. The conduits delivering neurotrophin-3 polyplexes resulted in significantly increased neurotrophin-3 levels in the surrounding tissue and a statistically higher number of regenerated axons versus the control conduits (P<0.05). This study suggests that collagen neural conduits delivering a highly effective non-viral therapeutic gene may hold promise for repair of the injured spinal cord.

  12. Zero-leak valve

    NASA Technical Reports Server (NTRS)

    Macglashan, W. F., Jr.

    1980-01-01

    Zero-leakage valve has fluid-sealing diaphragm support and flat sievelike sealing surface. Diaphragm-support valve is easy to fabricate and requires minimum maintenance. Potential applications include isolation valve for waste systems and remote air-actuated valve. Device is also useful in controlling flow of liquid fluorine and corrosive fluids at high pressures.

  13. Redo aortic valve surgery versus transcatheter valve-in-valve implantation for failing surgical bioprosthetic valves: consecutive patients in a single-center setting

    PubMed Central

    Wottke, Michael; Deutsch, Marcus-André; Krane, Markus; Piazza, Nicolo; Lange, Ruediger; Bleiziffer, Sabine

    2015-01-01

    Background Due to a considerable rise in bioprosthetic as opposed to mechanical valve implantations, an increase of patients presenting with failing bioprosthetic surgical valves in need of a reoperation is to be expected. Redo surgery may pose a high-risk procedure. Transcatheter aortic valve-in-valve implantation is an innovative, less-invasive treatment alternative for these patients. However, a comprehensive evaluation of the outcome of consecutive patients after a valve-in-valve TAVI [transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV)] as compared to a standard reoperation [surgical aortic valve redo-operation (SAV-in-SAV)] has not yet been performed. The goal of this study was to compare postoperative outcomes after TAV-in-SAV and SAV-in-SAV in a single center setting. Methods All SAV-in-SAV and TAV-in-SAV patients from January 2001 to October 2014 were retrospectively reviewed. Patients with previous mechanical or transcatheter valves, active endocarditis and concomitant cardiac procedures were excluded. Patient characteristics, preoperative data, post-procedural complications, and 30-day mortality were collected from a designated database. Mean values ± SD were calculated for all continuous variables. Counts and percentages were calculated for categorical variables. The Chi-square and Fisher exact tests were used to compare categorical variables. Continuous variables were compared using the t-test for independent samples. A 2-sided P value <0.05 was considered statistically significant. Results A total of 102 patients fulfilled the inclusion criteria, 50 patients (49%) underwent a transcatheter valve-in-valve procedure, while 52 patients (51%) underwent redo-surgery. Patients in the TAV-in-SAV group were significantly older, had a higher mean logistic EuroSCORE and exhibited a lower mean left ventricular ejection fraction than patients in the SAV-in-SAV group (78.1±6.7 vs. 66.2±13.1, P<0.001; 27.4±18.7 vs. 14.4±10, P<0.001; and 49.8±13

  14. Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

    PubMed

    Shi, Yubing; Yeo, Tony Joon Hock; Zhao, Yong; Hwang, Ned H C

    2006-12-01

    Particle Image Velocimetry (PIV) is an important technique in studying blood flow in heart valves. Previous PIV studies of flow around prosthetic heart valves had different research concentrations, and thus never provided the physical flow field pictures in a complete heart cycle, which compromised their pertinence for a better understanding of the valvular mechanism. In this study, a digital PIV (DPIV) investigation was carried out with improved accuracy, to analyse the pulsatile flow field around the bi-leaflet mechanical heart valve (MHV) in a complete heart cycle. For this purpose a pulsatile flow test rig was constructed to provide the necessary in vitro test environment, and the flow field around a St. Jude size 29 bi-leaflet MHV and a similar MHV model were studied under a simulated physiological pressure waveform with flow rate of 5.2 l/min and pulse rate at 72 beats/min. A phase-locking method was applied to gate the dynamic process of valve leaflet motions. A special image-processing program was applied to eliminate optical distortion caused by the difference in refractive indexes between the blood analogue fluid and the test section. Results clearly showed that, due to the presence of the two leaflets, the valvular flow conduit was partitioned into three flow channels. In the opening process, flow in the two side channels was first to develop under the presence of the forward pressure gradient. The flow in the central channel was developed much later at about the mid-stage of the opening process. Forward flows in all three channels were observed at the late stage of the opening process. At the early closing process, a backward flow developed first in the central channel. Under the influence of the reverse pressure gradient, the flow in the central channel first appeared to be disturbed, which was then transformed into backward flow. The backward flow in the central channel was found to be the main driving factor for the leaflet rotation in the valve

  15. Frequent Infection of Human Cancer Xenografts with Murine Endogenous Retroviruses in Vivo

    PubMed Central

    Naseer, Asif; Terry, Anne; Gilroy, Kathryn; Kilbey, Anna; Watts, Ciorsdaidh; Mackay, Nancy; Bell, Margaret; Mason, Susan; Blyth, Karen; Cameron, Ewan; Neil, James C.

    2015-01-01

    Infection of human cancer xenografts in mice with murine leukemia viruses (MLVs) is a long-standing observation, but the likelihood of infection in vivo and its biological consequences are poorly understood. We therefore conducted a prospective study in commonly used xenograft recipient strains. From BALB/c nude mice engrafted with MCF7 human mammary carcinoma cells, we isolated a virus that was virtually identical to Bxv1, a locus encoding replication-competent xenotropic MLV (XMLV). XMLV was detected in 9/17 (53%) independently isolated explants. XMLV was not found in primary leukemias or in THP1 leukemia cells grown in Bxv1-negative NSG (NOD/SCID/γCnull) mice, although MCF7 explants harbored replication-defective MLV proviruses. To assess the significance of infection for xenograft behavior in vivo, we examined changes in growth and global transcription in MCF7 and the highly susceptible Raji Burkitt lymphoma cell line chronically infected with XMLV. Raji cells showed a stronger transcriptional response that included up-regulation of chemokines and effectors of innate antiviral immunity. In conclusion, the risk of de novo XMLV infection of xenografts is high in Bxv1 positive mice, while infection can have positive or negative effects on xenograft growth potential with significant consequences for interpretation of many xenograft studies. PMID:25912714

  16. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  17. Apparatus for controlling fluid flow in a conduit wall

    DOEpatents

    Glass, S. Jill; Nicolaysen, Scott D.; Beauchamp, Edwin K.

    2003-05-13

    A frangible rupture disk and mounting apparatus for use in blocking fluid flow, generally in a fluid conducting conduit such as a well casing, a well tubing string or other conduits within subterranean boreholes. The disk can also be utilized in above-surface pipes or tanks where temporary and controllable fluid blockage is required. The frangible rupture disk is made from a pre-stressed glass with controllable rupture properties wherein the strength distribution has a standard deviation less than approximately 5% from the mean strength. The frangible rupture disk has controllable operating pressures and rupture pressures.

  18. Scissor thrust valve actuator

    DOEpatents

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  19. Device and method for measuring multi-phase fluid flow in a conduit having an abrupt gradual bend

    DOEpatents

    Ortiz, M.G.

    1998-02-10

    A system is described for measuring fluid flow in a conduit having an abrupt bend. The system includes pressure transducers, one disposed in the conduit at the inside of the bend and one or more disposed in the conduit at the outside of the bend but spaced a distance therefrom. The pressure transducers measure the pressure of fluid in the conduit at the locations of the pressure transducers and this information is used by a computational device to calculate fluid flow rate in the conduit. For multi-phase fluid, the density of the fluid is measured by another pair of pressure transducers, one of which is located in the conduit elevationally above the other. The computation device then uses the density measurement along with the fluid pressure measurements, to calculate fluid flow. 1 fig.

  20. Device and method for measuring multi-phase fluid flow in a conduit having an abrupt gradual bend

    DOEpatents

    Ortiz, Marcos German

    1998-01-01

    A system for measuring fluid flow in a conduit having an abrupt bend. The system includes pressure transducers, one disposed in the conduit at the inside of the bend and one or more disposed in the conduit at the outside of the bend but spaced a distance therefrom. The pressure transducers measure the pressure of fluid in the conduit at the locations of the pressure transducers and this information is used by a computational device to calculate fluid flow rate in the conduit. For multi-phase fluid, the density of the fluid is measured by another pair of pressure transducers, one of which is located in the conduit elevationally above the other. The computation device then uses the density measurement along with the fluid pressure measurements, to calculate fluid flow.

  1. A nerve guidance conduit with topographical and biochemical cues: potential application using human neural stem cells

    NASA Astrophysics Data System (ADS)

    Jenkins, Phillip M.; Laughter, Melissa R.; Lee, David J.; Lee, Young M.; Freed, Curt R.; Park, Daewon

    2015-06-01

    Despite major advances in the pathophysiological understanding of peripheral nerve damage, the treatment of nerve injuries still remains an unmet medical need. Nerve guidance conduits present a promising treatment option by providing a growth-permissive environment that 1) promotes neuronal cell survival and axon growth and 2) directs axonal extension. To this end, we designed an electrospun nerve guidance conduit using a blend of polyurea and poly-caprolactone with both biochemical and topographical cues. Biochemical cues were integrated into the conduit by functionalizing the polyurea with RGD to improve cell attachment. Topographical cues that resemble natural nerve tissue were incorporated by introducing intraluminal microchannels aligned with nanofibers. We determined that electrospinning the polymer solution across a two electrode system with dissolvable sucrose fibers produced a polymer conduit with the appropriate biomimetic properties. Human neural stem cells were cultured on the conduit to evaluate its ability to promote neuronal growth and axonal extension. The nerve guidance conduit was shown to enhance cell survival, migration, and guide neurite extension.

  2. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    PubMed Central

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  3. Finite element modeling of self-potential signals over conduits and fractures in covered karst terrain Peter Bumpus and Sarah Kruse

    NASA Astrophysics Data System (ADS)

    Bumpus, P. B.; Kruse, S. E.

    2013-12-01

    A year of continuous monitoring with two grids of 12-15 electrodes each measured self-potential (SP) over two small covered-karst conduits in Tampa, Florida. Positive and negative SP anomalies episodically manifested over conduits, suggesting that conduit flow is dynamic, not static. Various SP flow regimes in the conduits are postulated: flow in the conduit is faster than through surrounding surficial sediment, flow in the conduit is slower than through surrounding sediment, and conduit flow rates match those through the surrounding sediments. It is further postulated that conduits change permeability with inflow and washing out of sediment, especially associated with rain events. Numerical simulations of the postulated flow regimes were run with 2D simulations using the Comsol finite element modeling code. Simulations show that each regime produces different SP patterns. Models simulate the Tampa field setting in which a 1-2 meter-thick high permeability sand layer overlies a low-permeability clay-rich layer. A funnel-shaped conduit breaches both layers. In the models, when the permeability of the conduit sands is equal to surrounding surficial sands, a small (several mV) negative anomaly manifests locally at the conduit. This negative anomaly can be explained as the result of the depression of the SPS surface (the first sediment surface with a change in conductance or streaming potential coefficient) in the conduit. However a permeability difference of as little as 5 to 20 percent between conduit and background can cause an SP anomaly of tens to several hundred millivolts, either positive or negative. When the permeability is higher in the conduit than the surficial sands, lateral flow into the conduit within the sand layer and through the conduit to the underlying aquifer are both high, and the SP signal over the conduit is positive. This may contradict the concept exemplified in other studies that downward flow creates a negative anomaly. In our case the

  4. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    PubMed

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  5. Systems and method for delivering liquified gas to an engine

    DOEpatents

    Bingham, Dennis N.; Wilding, Bruce M.; O'Brien, James E.; Siahpush, Ali S.; Brown, Kevin B.

    2002-01-01

    A liquified gas delivery system for a motorized platform includes a holding tank configured to receive liquified gas. A first conduit extends from a vapor holding portion of the tank to a valve device. A second conduit extends from a liquid holding portion of the tank to the valve device. Fluid coupled to the valve device is a vaporizer which is in communication with an engine. The valve device selectively withdraws either liquified gas or liquified gas vapor from the tank depending on the pressure within the vapor holding portion of the tank. Various configurations of the delivery system can be utilized for pressurizing the tank during operation.

  6. Methods For Delivering Liquified Gas To An Engine

    DOEpatents

    Bingham, Dennis N.; Wilding, Bruce M.; O'Brien, James E.; Siahpush, Ali S.; Brown, Kevin B.

    2003-09-16

    A liquified gas delivery system for a motorized platform includes a holding tank configured to receive liquified gas. A first conduit extends from a vapor holding portion of the tank to a valve device. A second conduit extends from a liquid holding portion of the tank to the valve device. Fluid coupled to the valve device is a vaporizer which is in communication with an engine. The valve device selectively withdraws either liquified gas or liquified gas vapor from the tank depending on the pressure within the vapor holding portion of the tank. Various configurations of the delivery system can be utilized for pressurizing the tank during operation.

  7. Methods For Delivering Liquified Gas To An Engine

    DOEpatents

    Bingham, Dennis N.; Wilding, Bruce M.; O'Brien, James E.; Siahpush, Ali S.; Brown, Kevin B.

    2005-10-11

    A liquified gas delivery system for a motorized platform includes a holding tank configured to receive liquified gas. A first conduit extends from a vapor holding portion of the tank to a valve device. A second conduit extends from a liquid holding portion of the tank to the valve device. Fluid coupled to the valve device is a vaporizer which is in communication with an engine. The valve device selectively withdraws either liquified gas or liquified gas vapor from the tank depending on the pressure within the vapor holding portion of the tank. Various configurations of the delivery system can be utilized for pressurizing the tank during operation.

  8. Systems for delivering liquified gas to an engine

    DOEpatents

    Bingham, Dennis N.; Wilding, Bruce M.; O'Brien, James E.; Siahpush, Ali S.; Brown, Kevin B.

    2006-05-16

    A liquified gas delivery system for a motorized platform includes a holding tank configured to receive liquified gas. A first conduit extends from a vapor holding portion of the tank to a valve device. A second conduit extends from a liquid holding portion of the tank to the valve device. Fluid coupled to the valve device is a vaporizer which is in communication with an engine. The valve device selectively withdraws either liquified gas or liquified gas vapor from the tank depending on the pressure within the vapor holding portion of the tank. Various configurations of the delivery system can be utilized for pressurizing the tank during operation.

  9. Aortic valve repair leads to a low incidence of valve-related complications.

    PubMed

    Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim

    2010-01-01

    Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  10. Effects of nerve cells and adhesion molecules on nerve conduit for peripheral nerve regeneration

    PubMed Central

    Fiorellini, Joseph P.

    2017-01-01

    Background For peripheral nerve regeneration, recent attentions have been paid to the nerve conduits made by tissue-engineering technique. Three major elements of tissue-engineering are cells, molecules, and scaffolds. Methods In this study, the attachments of nerve cells, including Schwann cells, on the nerve conduit and the effects of both growth factor and adhesion molecule on these attachments were investigated. Results The attachment of rapidly-proliferating cells, C6 cells and HS683 cells, on nerve conduit was better than that of slowly-proliferating cells, PC12 cells and Schwann cells, however, the treatment of nerve growth factor improved the attachment of slowly-proliferating cells. In addition, the attachment of Schwann cells on nerve conduit coated with fibronectin was as good as that of Schwann cells treated with glial cell line-derived neurotrophic factor (GDNF). Conclusions Growth factor changes nerve cell morphology and affects cell cycle time. And nerve growth factor or fibronectin treatment is indispensable for Schwann cell to be used for implantation in artificial nerve conduits. PMID:29090249

  11. Valve

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

  12. Multi-port valve assembly

    DOEpatents

    Guggenheim, S. Frederic

    1986-01-01

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.

  13. Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis.

    PubMed

    Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad

    2018-05-20

    Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.

  14. A novel electrospun nerve conduit enhanced by carbon nanotubes for peripheral nerve regeneration

    NASA Astrophysics Data System (ADS)

    Yu, Wenwen; Jiang, Xinquan; Cai, Ming; Zhao, Wen; Ye, Dongxia; Zhou, Yong; Zhu, Chao; Zhang, Xiuli; Lu, Xiaofeng; Zhang, Zhiyuan

    2014-04-01

    For artificial nerve conduits, great improvements have been achieved in mimicking the structures and components of autologous nerves. However, there are still some problems in conduit construction, especially in terms of mechanical properties, biomimetic surface tomography, electrical conductivity and sustained release of neurotrophic factors or cells. In this study, we designed and fabricated a novel electrospun nerve conduit enhanced by multi-walled carbon nanotubes (MWNTs) on the basis of a collagen/poly(ɛ-caprolactone) (collagen/PCL) fibrous scaffold. Our aim was to provide further knowledge about the mechanical effects and efficacy of MWNTs on nerve conduits as well as the biocompatibility and toxicology of MWNTs when applied in vivo. The results showed that as one component, carboxyl MWNTs could greatly alter the composite scaffold’s hydrophilicity, mechanical properties and degradability. The electrospun fibers enhanced by MWNTs could support Schwann cell adhesion and elongation as a substrate in vitro. In vivo animal studies demonstrated that the MWNT-enhanced collagen/PCL conduit could effectively promote nerve regeneration of sciatic nerve defect in rats and prevent muscle atrophy without invoking body rejection or serious chronic inflammation. All of these results showed that this MWNT-enhanced scaffold possesses good biocompatibility and MWNTs might be excellent candidates as engineered nanocarriers for further neurotrophic factor delivery research.

  15. A novel electrospun nerve conduit enhanced by carbon nanotubes for peripheral nerve regeneration.

    PubMed

    Yu, Wenwen; Jiang, Xinquan; Cai, Ming; Zhao, Wen; Ye, Dongxia; Zhou, Yong; Zhu, Chao; Zhang, Xiuli; Lu, Xiaofeng; Zhang, Zhiyuan

    2014-04-25

    For artificial nerve conduits, great improvements have been achieved in mimicking the structures and components of autologous nerves. However, there are still some problems in conduit construction, especially in terms of mechanical properties, biomimetic surface tomography, electrical conductivity and sustained release of neurotrophic factors or cells. In this study, we designed and fabricated a novel electrospun nerve conduit enhanced by multi-walled carbon nanotubes (MWNTs) on the basis of a collagen/poly(ε-caprolactone) (collagen/PCL) fibrous scaffold. Our aim was to provide further knowledge about the mechanical effects and efficacy of MWNTs on nerve conduits as well as the biocompatibility and toxicology of MWNTs when applied in vivo.The results showed that as one component, carboxyl MWNTs could greatly alter the composite scaffold's hydrophilicity, mechanical properties and degradability. The electrospun fibers enhanced by MWNTs could support Schwann cell adhesion and elongation as a substrate in vitro. In vivo animal studies demonstrated that the MWNT-enhanced collagen/PCL conduit could effectively promote nerve regeneration of sciatic nerve defect in rats and prevent muscle atrophy without invoking body rejection or serious chronic inflammation. All of these results showed that this MWNT-enhanced scaffold possesses good biocompatibility and MWNTs might be excellent candidates as engineered nanocarriers for further neurotrophic factor delivery research.

  16. Uncovering Offshore Financial Centers: Conduits and Sinks in the Global Corporate Ownership Network.

    PubMed

    Garcia-Bernardo, Javier; Fichtner, Jan; Takes, Frank W; Heemskerk, Eelke M

    2017-07-24

    Multinational corporations use highly complex structures of parents and subsidiaries to organize their operations and ownership. Offshore Financial Centers (OFCs) facilitate these structures through low taxation and lenient regulation, but are increasingly under scrutiny, for instance for enabling tax avoidance. Therefore, the identification of OFC jurisdictions has become a politicized and contested issue. We introduce a novel data-driven approach for identifying OFCs based on the global corporate ownership network, in which over 98 million firms (nodes) are connected through 71 million ownership relations. This granular firm-level network data uniquely allows identifying both sink-OFCs and conduit-OFCs. Sink-OFCs attract and retain foreign capital while conduit-OFCs are attractive intermediate destinations in the routing of international investments and enable the transfer of capital without taxation. We identify 24 sink-OFCs. In addition, a small set of five countries - the Netherlands, the United Kingdom, Ireland, Singapore and Switzerland - canalize the majority of corporate offshore investment as conduit-OFCs. Each conduit jurisdiction is specialized in a geographical area and there is significant specialization based on industrial sectors. Against the idea of OFCs as exotic small islands that cannot be regulated, we show that many sink and conduit-OFCs are highly developed countries.

  17. Force measuring valve assemblies, systems including such valve assemblies and related methods

    DOEpatents

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  18. Magnetically operated check valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G. (Inventor); Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  19. Magnetically operated check valve

    NASA Astrophysics Data System (ADS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  20. Modifications to the Conduit Flow Process Mode 2 for MODFLOW-2005

    USGS Publications Warehouse

    Reimann, T.; Birk, S.; Rehrl, C.; Shoemaker, W.B.

    2012-01-01

    As a result of rock dissolution processes, karst aquifers exhibit highly conductive features such as caves and conduits. Within these structures, groundwater flow can become turbulent and therefore be described by nonlinear gradient functions. Some numerical groundwater flow models explicitly account for pipe hydraulics by coupling the continuum model with a pipe network that represents the conduit system. In contrast, the Conduit Flow Process Mode 2 (CFPM2) for MODFLOW-2005 approximates turbulent flow by reducing the hydraulic conductivity within the existing linear head gradient of the MODFLOW continuum model. This approach reduces the practical as well as numerical efforts for simulating turbulence. The original formulation was for large pore aquifers where the onset of turbulence is at low Reynolds numbers (1 to 100) and not for conduits or pipes. In addition, the existing code requires multiple time steps for convergence due to iterative adjustment of the hydraulic conductivity. Modifications to the existing CFPM2 were made by implementing a generalized power function with a user-defined exponent. This allows for matching turbulence in porous media or pipes and eliminates the time steps required for iterative adjustment of hydraulic conductivity. The modified CFPM2 successfully replicated simple benchmark test problems. ?? 2011 The Author(s). Ground Water ?? 2011, National Ground Water Association.

  1. Enhancing Peripheral Nerve Regeneration with a Novel Drug Delivering Nerve Conduit

    DTIC Science & Technology

    2017-12-01

    control group ) or a conduit that released GDNF. The main outcome measures were muscle atrophy, electrophysiology, motor endplate reinnervation...prepared NGF+GDNF ( Control groups ). 8 Gastrocnemius Atrophy The gastrocnemius muscle weight of the GDNF treated group was ~ 60% of the non...experimental side at 10 weeks. GDNF conduit group (49.4±1.4 %) had statistically less muscle atrophy than the control group (65.1±5.1 %) (pɘ.05) at 10

  2. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  3. Havery Mudd 2014-2015 Computer Science Conduit Clinic Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aspesi, G; Bai, J; Deese, R

    2015-05-12

    Conduit, a new open-source library developed at Lawrence Livermore National Laboratories, provides a C++ application programming interface (API) to describe and access scientific data. Conduit’s primary use is for inmemory data exchange in high performance computing (HPC) applications. Our team tested and improved Conduit to make it more appealing to potential adopters in the HPC community. We extended Conduit’s capabilities by prototyping four libraries: one for parallel communication using MPI, one for I/O functionality, one for aggregating performance data, and one for data visualization.

  4. Automatic shutoff valve

    NASA Technical Reports Server (NTRS)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  5. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    PubMed

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. A Biosynthetic Nerve Guide Conduit Based on Silk/SWNT/Fibronectin Nanocomposite for Peripheral Nerve Regeneration

    PubMed Central

    Mottaghitalab, Fatemeh; Farokhi, Mehdi; Zaminy, Arash; Kokabi, Mehrdad; Soleimani, Masoud; Mirahmadi, Fereshteh

    2013-01-01

    As a contribution to the functionality of nerve guide conduits (NGCs) in nerve tissue engineering, here we report a conduit processing technique through introduction and evaluation of topographical, physical and chemical cues. Porous structure of NGCs based on freeze-dried silk/single walled carbon nanotubes (SF/SWNTs) has shown a uniform chemical and physical structure with suitable electrical conductivity. Moreover, fibronectin (FN) containing nanofibers within the structure of SF/SWNT conduits produced through electrospinning process have shown aligned fashion with appropriate porosity and diameter. Moreover, fibronectin remained its bioactivity and influenced the adhesion and growth of U373 cell lines. The conduits were then implanted to 10 mm left sciatic nerve defects in rats. The histological assessment has shown that nerve regeneration has taken places in proximal region of implanted nerve after 5 weeks following surgery. Furthermore, nerve conduction velocities (NCV) and more myelinated axons were observed in SF/SWNT and SF/SWNT/FN groups after 5 weeks post implantation, indicating a functional recovery for the injured nerves. With immunohistochemistry, the higher S-100 expression of Schwann cells in SF/SWNT/FN conduits in comparison to other groups was confirmed. In conclusion, an oriented conduit of biocompatible SF/SWNT/FN has been fabricated with acceptable structure that is particularly applicable in nerve grafts. PMID:24098649

  7. Overflow control valve

    DOEpatents

    Hundal, Rolv; Kessinger, Boyd A.; Parlak, Edward A.

    1984-07-24

    An overflow control valve for use in a liquid sodium coolant pump tank which valve can be extended to create a seal with the pump tank wall or retracted to break the seal thereby accommodating valve removal. An actuating shaft which controls valve disc position also has cams which bear on roller surfaces to force retraction of a sliding cylinder against spring tension to retract the cylinder from sealing contact with the pump tank.

  8. Aerodynamic Shutoff Valve

    NASA Technical Reports Server (NTRS)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  9. Mesofluidic two stage digital valve

    DOEpatents

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  10. Apparatus for gas sorption measurement with integrated gas composition measurement device and gas mixing

    DOEpatents

    Micklash. II, Kenneth James; Dutton, Justin James; Kaye, Steven

    2014-06-03

    An apparatus for testing of multiple material samples includes a gas delivery control system operatively connectable to the multiple material samples and configured to provide gas to the multiple material samples. Both a gas composition measurement device and pressure measurement devices are included in the apparatus. The apparatus includes multiple selectively openable and closable valves and a series of conduits configured to selectively connect the multiple material samples individually to the gas composition device and the pressure measurement devices by operation of the valves. A mixing system is selectively connectable to the series of conduits and is operable to cause forced mixing of the gas within the series of conduits to achieve a predetermined uniformity of gas composition within the series of conduits and passages.

  11. Main Oxidizer Valve Design

    NASA Technical Reports Server (NTRS)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  12. Slow opening valve. [valve design for shuttle portable oxygen system

    NASA Technical Reports Server (NTRS)

    Drapeau, D. F. (Inventor)

    1984-01-01

    A valve control is described having a valve body with an actuator stem and a rotating handle connected to the actuator stem by a differential drive mechanism which, during uniform movement of the handle in one direction, initially opens the valve at a relatively slow rate and, thereafter, complete the valve movement at a substantially faster rate. A series of stop rings are received about the body in frictional abutting relationship and serially rotated by the handle to uniformly resist handle movement independently of the extent of handle movement.

  13. Effects of morphologic left ventricular pressure on right ventricular geometry and tricuspid valve regurgitation in patients with congenitally corrected transposition of the great arteries.

    PubMed

    Kral Kollars, Catharine A; Gelehrter, Sarah; Bove, Edward L; Ensing, Gregory

    2010-03-01

    Congenitally corrected transposition of the great arteries (CCTGA) is associated with tricuspid regurgitation (TR), which has been postulated to arise from the effect of ventricular septal position on the attachments of the tricuspid valve. This study was performed to determine the effect of left ventricular (LV) pressure on right ventricular (RV) and LV geometry and the degree of TR. Serial echocardiograms were reviewed from, 30 patients with CCTGA who underwent pulmonary artery banding to train the morphologic left ventricle (n = 14) or left ventricle-to-pulmonary artery conduit placement and ventricular septal defect closure in conjunction with physiologic repair (n = 16). The degree of TR, the LV/RV pressure ratio, RV and LV sphericity indexes, and tricuspid valve tethering distance and coaptation length were analyzed. After pulmonary artery banding, an increase in LV systolic pressure to > or =2/3 systemic resulted in a decrease in TR from severe to moderate (p = 0.02). The percentage of patients with severe TR decreased from 64% to 18% (p = 0.06). The RV sphericity index decreased (p = 0.05), and the LV sphericity index increased (p = 0.02). After left ventricle-to-pulmonary artery conduit placement, a decrease in LV pressure to < or =1/2 systemic resulted in an increase in TR from none to mild (p = 0.003). In conclusion, these data indicate that LV pressure in patients with CCTGA affects the degree of TR and that septal shift caused by changes in LV and RV pressure is an important mechanism. Copyright 2010. Published by Elsevier Inc.

  14. Device useful as a borehole fluid sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freifeld, Barry M.

    The present invention provides a device comprising: (a) a proximal end of the device comprises an inner first conduit within the lumen of an outer second conduit, (b) a distal end of the device comprises the outer second conduit in fluid communication with a third conduit and a fourth conduit through a Y-shaped, T-shaped or U-shaped junction, (c) the third conduit terminates in a triggering mechanism, and (d) the fourth conduit is in fluid communication through a one-way valve, wherein fluid can only convey in a direction from the fourth conduit towards the second outer conduit, with an aperture.

  15. Lightweight Motorized Valve

    NASA Technical Reports Server (NTRS)

    Gonzalez, R.; Vandewalle, J.

    1986-01-01

    Redesigned actuator assembly weighs 50 percent less. Isolator valve operated by ac motor instead of usual dc solenoid. Valve weighs only 3 lb (1.4 kg). New valve functions with either two-phase or three-phase power. Developed for isolating fluids in propellant tanks, manifolds, and interconnecting lines of Space Shuttle reaction control and orbital maneuvering subsystems, valve suited to applications in which leakage must be kept to minimum at high pressure differences - in petroleum and chemical processing.

  16. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    PubMed

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. The Influence of Conduit Processes During Basaltic Plinian Eruptions.

    NASA Astrophysics Data System (ADS)

    Houghton, B. F.; Sable, J. E.; Wilson, C. J.; Coltelli, M.; Del Carlo, P.

    2001-12-01

    Basaltic volcanism is most typically thought to produce effusion of lava, with the most explosive manifestations ranging from mild Strombolian activity to more energetic fire fountain eruptions. However, some basaltic eruptions are now recognized as extremely violent, i.e. generating widespread phreatomagmatic, subplinian and Plinian fall deposits. These eruptions are particularly dangerous because the ascent rate of basaltic magma prior to eruption can be very rapid (giving warning times as little as a few hours) and because their precursors may be ignored or misunderstood. The main question addressed in this talk is: what conditions in the conduit cause basaltic magma to adopt an eruption style more typical of chemically evolved, highly viscous magmas? Possible mechanisms (acting singly, or in concert) are: (1) interaction between magma and water, (ii) very rapid ascent producing a delayed onset of degassing then exceptionally rapid "runaway" vesiculation at shallow levels in the conduit, (iii) microlite crystallization and degassing of the magma during ascent leading to increased viscosity. We focus here on two examples of basaltic Plinian volcanism: the 1886 eruption of Tarawera, New Zealand, which is the youngest known basaltic Plinian eruption and the only one for which there are detailed written eyewitness accounts, and the well documented 122 BC eruption of Mount Etna, Italy. Field and laboratory evidence suggests that the Plinian phase of the 1886 eruption was a consequence of two processes. Firstly rheologic changes during magma ascent accompanied early (pre-fragmentation) interaction between the basaltic melt and water-bearing rhyolitic units forming the conduit walls and, secondly, late-stage magma:water interaction. In contrast, during the 122 BC eruption tectonic processes, such as slope failure or permanent displacement of a mobile flank of the volcano, appear to have triggered exceptionally rapid ascent, delayed onset of degassing and exceptionally

  18. Structures and lithofacies of inferred silicic conduits in the Paraná-Etendeka LIP, southernmost Brazil

    NASA Astrophysics Data System (ADS)

    Simões, M. S.; Lima, E. F.; Sommer, C. A.; Rossetti, L. M. M.

    2018-04-01

    Extensive silicic units in the Paraná-Etendeka LIP have been long interpreted as pyroclastic density currents (rheomorphic ignimbrites) derived from the Messum Complex in Namibia. In recent literature, however, they have been characterized as effusive lava flows and domes. In this paper we describe structures and lithofacies related to postulated silicic lava feeder conduits at Mato Perso, São Marcos and Jaquirana-Cambará do Sul areas in southern Brazil. Inferred conduits are at least 15-25 m in width and the lithofacies include variably vesicular monomictic welded and non-welded breccias in the margins to poorly vesicular, banded, spherulitic and microfractured vitrophyres in the central parts. Flat-lying coherent vitrophyres and massive obsidian are considered to be the subaerial equivalents of the conduits. Large-scale, regional tectonic structures in southern Brazil include the NE-SW aligned Porto Alegre Suture, Leão and Açotea faults besides the Antas Lineament, a curved tectonic feature accompanying the bed of Antas river. South of the Antas Lineament smaller-scale, NW-SE lineaments limit the exposure areas of the inferred conduits. NE-SW and subordinate NW-SE structures within this smaller-scale lineaments are represented by the main postulated conduit outcrops and are parallel to the dominant sub-vertical banding in the widespread banded vitrophyre lithofacies. Upper lava flows display flat-lying foliation, pipe-like and spherical vesicles and have better developed microlites. Petrographic characteristics of the silicic vitrophyres indicate that crystal-poor magmas underwent distinct cooling paths for each inferred conduit area. The vitrophyre chemical composition is defined by the evolution of trachydacitic/dacitic vitrophyres with 62-65 wt% SiO2 to rhyodacite and rhyolite with 66-68 wt% SiO2. The more evolved rocks are assigned to the latest intrusive grey vitrophyre outcropping in the center of the conduits. Degassing pathways formed during

  19. Heart Valve Diseases

    MedlinePlus

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  20. Temporal morphologic changes in human colorectal carcinomas following xenografting.

    PubMed

    Barkla, D H; Tutton, P J

    1983-03-01

    The temporal morphologic changes of human colorectal carcinomas following xenografting into immunosuppressed mice were investigated by the use of light and transmission electron microscopy. The results show that colorectal carcinomas undergo a series of morphologic changes during the initial 30-day period following transplantation. During the initial 1-5-day period the majority of tumor cells die, and during the following 5-10-day period the necrotic debris created during the 1-5-day period is removed by host-supplied inflammatory cells. Only small groups of peripherally placed tumor cells survived at the end of the first 10 days. During the 10-20-day period the tumor cell populations of xenografts were reestablished by a morphologically heterogeneous population of tumor cells, and during the 20-30 day period consolidation of this process continued and some xenografts showed macroscopic evidence of growth. The authors hypothesize that human colorectal carcinomas, like the antecedent epithelium, contain subpopulations of undifferentiated cells that give rise to populations of more-differentiated cells.

  1. Single-friction-surface triboelectric generator with human body conduit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meng, Bo; Cheng, Xiaoliang; Zhang, Xiaosheng

    2014-03-10

    We present a transparent single-friction-surface triboelectric generator (STEG) employing human body as the conduit, making the applications of STEG in portable electronics much more practical and leading to a significant output improvement. The STEG with micro-patterned polydimethylsiloxane surface achieved an output voltage of over 200 V with a current density of 4.7 μA/cm{sup 2}. With human body conduit, the output current increased by 39% and the amount of charge that transferred increased by 34% compared to the results with grounded electrode. A larger increment of 210% and 81% was obtained in the case of STEG with a large-size flat polyethylenemore » terephthalate surface.« less

  2. Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

    PubMed Central

    Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin

    2015-01-01

    Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380

  3. Kangaroo versus porcine aortic valve tissue--valve geometry morphology, tensile strength and calcification potential.

    PubMed

    Neethling, W M; Papadimitriou, J M; Swarts, E; Hodge, A J

    2000-06-01

    Valve related factors and patient related factors are responsible for calcification of valvular bioprostheses. Recent studies showed different donor and recipient species have different influences on the total calcification rate of bioprostheses. This study was performed to evaluate and compare Kangaroo aortic valve leaflets with porcine aortic valve leaflets. Experimental design. Prospective study. Setting. Cardio-thoracic experimental research of a university department. Glutaraldehyde-fixed Kangaroo and porcine valve leaflets were evaluated in vitro according to valve geometry (internal diameter and leaflet thickness), morphology (light and electron microscopy) and tensile strength. In vivo evaluation consisted of implantation in a rat model for 8 weeks, Von Kossa stain for calcium and atomic absorption spectrophotometry for total extractable calcium content. Kangaroo valves indicated a smaller internal valve diameter as well as a thinner valve leaflet (p<0.01, ANOVA) at corresponding body weight, less proteoglycan spicules in the fibrosa, increased elasticity (p<0.05) and low calcification potential (p<0.01, confidence interval 95%). Kangaroo aortic valve leaflets have different valvular qualities compared to porcine valve tissue. Kangaroo valve leaflets are significantly superior to porcine valve leaflets as far as calcification is concerned. These results are encouraging and suggest further in vivo evaluation in a larger animal model before clinical application can be considered.

  4. What Is Heart Valve Surgery?

    MedlinePlus

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  5. What Is Heart Valve Disease?

    MedlinePlus

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  6. Valve repair in aortic regurgitation without root dilatation--aortic valve repair.

    PubMed

    Lausberg, H F; Aicher, D; Kissinger, A; Langer, F; Fries, R; Schäfers, H-J

    2006-02-01

    Aortic valve repair was established in the context of aortic root remodeling. Variable results have been reported for isolated valve repair. We analyzed our experience with isolated valve repair and compared the results with those of aortic root remodeling. Between October 1995 and August 2003, isolated repair of the aortic valve was performed in 83 patients (REP), remodeling of the aortic valve in 175 patients (REMO). The demographics of the two groups were comparable (REP: mean age 54.4 +/- 20.7 yrs, male-female ratio 2.1 : 1; REMO: mean age 60.8 +/- 13.6 yrs, male-female ratio 2.4 : 1; p = ns). In both groups the number of bicuspid valves was comparable (REP: 41 %, REMO: 32 %; p = ns). All patients were followed by echocardiography for a cumulative follow-up of 8204 patient months (mean 32 +/- 23 months). Overall in-hospital mortality was 2.4 % in REP and 4.6 % in REMO ( p = 0.62). Systolic gradients were comparable in both groups (REP: 5.8 +/- 2.2, REMO: 6.5 +/- 3.1 mm Hg, p = 0.09). The mean degree of aortic regurgitation 12 months postoperatively was 0.8 +/- 0.7 after REP and 0.7 +/- 0.7 after REMO ( p = 0.29). Freedom from significant regurgitation (> or = II degrees ) after 5 years was 86 % in REP and 89 % in REMO ( p = 0.17). Freedom from re-operation after 5 years was 94.4 % in REP and 98.2 % in REMO ( p = 0.33). Aortic regurgitation without concomitant root dilatation can be treated effectively by aortic valve repair. The functional results are equivalent to those obtained with valve-preserving root replacement. Aortic valve repair appears to be an alternative to valve replacement in aortic regurgitation.

  7. Total intracorporeal robot-assisted laparoscopic ileal conduit (Bricker) urinary diversion: technique and outcomes.

    PubMed

    Rehman, Jamil; Sangalli, Mattia N; Guru, Khurshid; de Naeyer, Geert; Schatteman, Peter; Carpentier, Paul; Mottrie, Alexander

    2011-02-01

    Several recent preliminary reports have demonstrated that Robot-Assisted Cystectomy with total intracorporeal Ileal Conduit (RACIC) is a feasible option over the open technique. We report our stepwise surgical procedure of robotic total intracorporeal ileal conduit urinary diversion, technical consideration, development, refinements and initial experience. Only the ileal conduit urinary diversion is described with no emphasis on the cystectomy's steps. Between February 2008 and September 2009, nine patients underwent RACIC for muscle invasive transitional cell carcinoma (TCC). The entire procedure, including radical cystoprostatectomy, extended pelvic node dissection (ePLND), ileal conduit urinary diversion (Bricker) including isolation of the ileal loop (20 cm ileal segment) 15 cm away from the ileocecal junction, restoration of bowel continuity with stapled side-to-side ileo-ileal anastomosis, retroperitoneal transfer of the left ureter to the right side, and bilateral stented (8 F feeding tube) ileo-ureteral anastomoses in a Wallace faction were all performed exclusively intracorporeally using the da Vinci Si surgical robot and finally the conduit stoma was fashioned. The RACIC was technically successful in all nine patients (three females and six males. Mean age 74.1; 57 to 87) without open conversion. The mean operative time including extended pelvic lymphadenectomy and urinary diversion was 346.2 minutes (210 to 480). Mean operative time of diversion is 72 minutes (52-113) mean estimated blood loss 258 mL (200 to 500) and the median hospital stay were 14 days (10 to 27). In all three female patients, the specimen was extracted through the vagina. There were no intraoperative complications and only one major postoperative complication: one postoperative iatrogenous necrosis of the ileal conduit caused by uncareful retraction of the organ bag and thereby probably injuring the conduit pedicle, as the ileal conduit was well vascularised at the end of the

  8. Methods of measuring pumpage through closed-conduit irrigation systems

    USGS Publications Warehouse

    Kjelstrom, L.C.

    1991-01-01

    Methods of measuring volumes of water withdrawn from the Snake River and its tributaries and pumped through closed-conduit irrigation systems were needed for equitable management of and resolution of conflicts over water use. On the basis of evaluations and field tests by researchers from the University of Idaho, Water Resources Research Institute, Moscow, Idaho, an impeller meter was selected to monitor pumpage through closed-conduit systems. In 1988, impeller meters were installed at 20 pumping stations along the Snake River between the Upper Salmon Falls and C.J. Strike Dams. Impeller-derived pumpage data were adjusted if they differed substantially from ultrasonic flow-meter- or current-meter-derived values. Comparisons of pumpage data obtained by ultrasonic flow-meter and current-meter measurements indicated that the ultrasonic flow meter was a reliable means to check operation of impeller meters. The equipment generally performed satisfactorily, and reliable pumpage data could be obtained using impeller meters in closed-conduit irrigation systems. Many pumping stations that divert water from the Snake River for irrigation remain unmeasured; however, regression analyses indicate that total pumpage can be reasonably estimated on the basis of electrical power consumption data, an approximation of total head at a pumping station, and a derived coefficient.

  9. Face-Sealing Butterfly Valve

    NASA Technical Reports Server (NTRS)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  10. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    PubMed

    O' Sullivan, Katie E; Casserly, Ivan; Hurley, John

    2015-04-01

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  11. Modeling the Mitral Valve

    NASA Astrophysics Data System (ADS)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  12. Magnetically operated check valve

    NASA Astrophysics Data System (ADS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1993-03-01

    A magnetically operated check valve is disclosed having, in one aspect, a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  13. Reduced Toxicity Fuel Satellite Propulsion System

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J. (Inventor)

    2001-01-01

    A reduced toxicity fuel satellite propulsion system including a reduced toxicity propellant supply for consumption in an axial class thruster and an ACS class thruster. The system includes suitable valves and conduits for supplying the reduced toxicity propellant to the ACS decomposing element of an ACS thruster. The ACS decomposing element is operative to decompose the reduced toxicity propellant into hot propulsive gases. In addition the system includes suitable valves and conduits for supplying the reduced toxicity propellant to an axial decomposing element of the axial thruster. The axial decomposing element is operative to decompose the reduced toxicity propellant into hot gases. The system further includes suitable valves and conduits for supplying a second propellant to a combustion chamber of the axial thruster, whereby the hot gases and the second propellant auto-ignite and begin the combustion process for producing thrust.

  14. Reduced Toxicity Fuel Satellite Propulsion System Including Plasmatron

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J. (Inventor)

    2003-01-01

    A reduced toxicity fuel satellite propulsion system including a reduced toxicity propellant supply for consumption in an axial class thruster and an ACS class thruster. The system includes suitable valves and conduits for supplying the reduced toxicity propellant to the ACS decomposing element of an ACS thruster. The ACS decomposing element is operative to decompose the reduced toxicity propellant into hot propulsive gases. In addition the system includes suitable valves and conduits for supplying the reduced toxicity propellant to an axial decomposing element of the axial thruster. The axial decomposing element is operative to decompose the reduced toxicity propellant into hot gases. The system further includes suitable valves and conduits for supplying a second propellant to a combustion chamber of the axial thruster. whereby the hot gases and the second propellant auto-ignite and begin the combustion process for producing thrust.

  15. Reduced Toxicity Fuel Satellite Propulsion System Including Fuel Cell Reformer with Alcohols Such as Methanol

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J. (Inventor)

    2001-01-01

    A reduced toxicity fuel satellite propulsion system including a reduced toxicity propellant supply for consumption in an axial class thruster and an ACS class thruster. The system includes suitable valves and conduits for supplying the reduced toxicity propellant to the ACS decomposing element of an ACS thruster. The ACS decomposing element is operative to decompose the reduced toxicity propellant into hot propulsive gases. In addition the system includes suitable valves and conduits for supplying the reduced toxicity propellant to an axial decomposing element of the axial thruster. The axial decomposing element is operative to decompose the reduced toxicity propellant into hot gases. The system further includes suitable valves and conduits for supplying a second propellant to a combustion chamber of the axial thruster, whereby the hot gases and the second propellant auto-ignite and begin the combustion process for producing thrust.

  16. Fast acting check valve

    NASA Technical Reports Server (NTRS)

    Perkins, Gerald S. (Inventor)

    1979-01-01

    A check valve which closes more rapidly to prevent wearing of the valve seat and of the valve member that seals thereagainst, including a solenoid or other actuator that aids the normal spring to quickly close the valve at approximately the time when downpath fluid flow would stop, the actuator then being deenergized. The control circuit that operates the actuator can include a pair of pressure sensors sensing pressure both upstream and downstream from the valve seat. Where the valve is utilized to control flow to or from a piston pump, energization of the actuator can be controlled by sensing when the pump piston reaches its extreme of travel.

  17. VLP seismicity from resonant modes of acoustic-gravity waves in a conduit-crack system filled with multiphase magma

    NASA Astrophysics Data System (ADS)

    Liang, C.; Prochnow, B. N.; OReilly, O. J.; Dunham, E. M.; Karlstrom, L.

    2016-12-01

    Oscillation of magma in volcanic conduits connected to cracks (dikes and sills) has been suggested as an explanation for very long period (VLP) seismic signals recorded at active basaltic volcanoes such as. Kilauea, Hawaii, and Erebus, Antarctica. We investigate the VLP seismicity using a linearized model for waves in and associated eigenmodes of a coupled conduit-crack system filled with multiphase magma, an extension of the Karlstrom and Dunham (2016) model for acoustic-gravity waves in volcanic conduits. We find that the long period surface displacement (as recorded on broadband seismometers) is dominated by opening/closing of the crack rather than the deformation of the conduit conduit walls. While the fundamental eigenmode is sensitive to the fluid properties and the geometry of the magma plumbing system, a closer scrutiny of various resonant modes reveals that the surface displacement is often more sensitive to higher modes. Here we present a systematic analysis of various long period acoustic-gravity wave resonant modes of a coupled conduit-crack system that the surface displacement is most sensitive to. We extend our previous work on a quasi-one-dimensional conduit model with inviscid magma to a more general axisymmetric conduit model that properly accounts for viscous boundary layers near the conduit walls, based on the numerical method developed by Prochnow et al. (submitted to Computers and Fluids, 2016). The surface displacement is dominated by either the fundamental or higher eigenmodes, depending on magma properties and the geometry of conduit and crack. An examination of the energetics of these modes reveals the complex interplay of different restoring forces (magma compressibility in the conduit, gravity, and elasticity of the crack) driving the VLP oscillations. Both nonequilibrium bubble growth and resorption and viscosity contribute to the damping of VLP signals. Our models thus provide a means to infer properties of open-vent basaltic volcanoes

  18. Flow Behavior in the Left Heart Ventricle Following Apico-Aortic Bypass Surgery

    NASA Astrophysics Data System (ADS)

    Shahriari, Shahrokh; Jeyhani, Morteza; Labrosse, Michel; Kadem, Lyes

    2013-11-01

    Apico-aortic bypass (AAB) surgery is an alternative for transcatheter aortic valve implantation (TAVI) to reduce left ventricle (LV) overload in patients with severe aortic stenosis (AS). It consists in connecting the apex of the LV to the descending thoracic aorta with a valved conduit. Postoperative flow assessments show that two thirds of the outflow is conducted from the LV apex to the conduit, while only one third crosses the native aortic valve. In this study, we performed high speed particle image velocimetry (PIV) measurements of flow pattern within an in vitro elastic model of LV in the presence of a very severe AS, before and after AAB. Results indicate that AAB effectively relieves the LV outflow obstruction; however, it also leads to abnormal ventricular flow patterns. Normal LV flow dynamics is characterized by an emerging mitral jet flow followed by the development of a vortical flow with velocities directed towards the aortic valve, while measurements in the presence of AAB show systolic flow bifurcating to the apical conduit and to the aortic valve outflow tract. This study provides the first insight into the LV flow structure after AAB including outflow jets and disturbed stagnation regions.

  19. Double-orifice mitral valve associated with bicuspid aortic valve.

    PubMed

    Khani, Mohammad; Rohani, Atoosheh

    2017-06-01

    Double-orifice mitral valve is a rare congenital anomaly that usually does not cause a significant hemodynamic effect. Double-orifice mitral valve and a bicuspid aortic valve were detected in a 54-year-old lady who presented with dyspnea on exertion for one year. This is a rare association. Three-dimensional echocardiography is helpful to determine the type of malformation. The patient had no significant mitral regurgitation or stenosis, but demonstrated moderate aortic stenosis. She is undergoing periodic monitoring.

  20. Maturation of the developing human fetal prostate in a rodent xenograft model

    PubMed Central

    Saffarini, Camelia M.; McDonnell, Elizabeth V.; Amin, Ali; Spade, Daniel J.; Huse, Susan M.; Kostadinov, Stefan; Hall, Susan J.; Boekelheide, Kim

    2015-01-01

    Background Prostate cancer is the most commonly diagnosed non-skin cancer in men. The etiology of prostate cancer is unknown, although both animal and epidemiologic data suggest that early life exposures to various toxicants, may impact DNA methylation status during development, playing an important role. Methods We have developed a xenograft model to characterize the growth and differentiation of human fetal prostate implants (gestational age 12-24 weeks) that can provide new data on the potential role of early life stressors on prostate cancer. The expression of key immunohistochemical markers responsible for prostate maturation was evaluated, including p63, cytokeratin 18, α-smooth muscle actin, vimentin, caldesmon, Ki-67, prostate specific antigen, estrogen receptor-α, and androgen receptor. Xenografts were separated into epithelial and stromal compartments using laser capture microdissection (LCM), and the DNA methylation status was assessed in >480,000 CpG sites throughout the genome. Results Xenografts demonstrated growth and maturation throughout the 200 days of post-implantation evaluation. DNA methylation profiles of laser capture micro-dissected tissue demonstrated tissue-specific markers clustered by their location in either the epithelium or stroma of human prostate tissue. Differential methylated promoter region CpG-associated gene analysis revealed significantly more stromal than epithelial DNA methylation in the 30 and 90-day xenografts. Functional classification analysis identified CpG-related gene clusters in methylated epithelial and stromal human xenografts. Conclusion This study of human fetal prostate tissue establishes a xenograft model that demonstrates dynamic growth and maturation, allowing for future mechanistic studies of the developmental origins of later life proliferative prostate disease. PMID:24038131

  1. Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?

    PubMed

    Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-11-01

    Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.

  2. Remote actuated valve implant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  3. Valve for fluid control

    DOEpatents

    Oborny, Michael C.; Paul, Phillip H.; Hencken, Kenneth R.; Frye-Mason, Gregory C.; Manginell, Ronald P.

    2001-01-01

    A valve for controlling fluid flows. This valve, which includes both an actuation device and a valve body provides: the ability to incorporate both the actuation device and valve into a unitary structure that can be placed onto a microchip, the ability to generate higher actuation pressures and thus control higher fluid pressures than conventional microvalves, and a device that draws only microwatts of power. An electrokinetic pump that converts electric potential to hydraulic force is used to operate, or actuate, the valve.

  4. Solid handling valve

    DOEpatents

    Williams, William R.

    1979-01-01

    The present invention is directed to a solids handling valve for use in combination with lock hoppers utilized for conveying pulverized coal to a coal gasifier. The valve comprises a fluid-actuated flow control piston disposed within a housing and provided with a tapered primary seal having a recessed seat on the housing and a radially expandable fluid-actuated secondary seal. The valve seals are highly resistive to corrosion, erosion and abrasion by the solids, liquids, and gases associated with the gasification process so as to minimize valve failure.

  5. VALVE

    DOEpatents

    Arkelyan, A.M.; Rickard, C.L.

    1962-04-17

    A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)

  6. Polyurethane/Gelatin Nanofibrils Neural Guidance Conduit Containing Platelet-Rich Plasma and Melatonin for Transplantation of Schwann Cells.

    PubMed

    Salehi, Majid; Naseri-Nosar, Mahdi; Ebrahimi-Barough, Somayeh; Nourani, Mohammdreza; Khojasteh, Arash; Farzamfar, Saeed; Mansouri, Korosh; Ai, Jafar

    2018-04-01

    The current study aimed to enhance the efficacy of peripheral nerve regeneration using a biodegradable porous neural guidance conduit as a carrier to transplant allogeneic Schwann cells (SCs). The conduit was prepared from polyurethane (PU) and gelatin nanofibrils (GNFs) using thermally induced phase separation technique and filled with melatonin (MLT) and platelet-rich plasma (PRP). The prepared conduit had the porosity of 87.17 ± 1.89%, the contact angle of 78.17 ± 5.30° and the ultimate tensile strength and Young's modulus of 5.40 ± 0.98 MPa and 3.13 ± 0.65 GPa, respectively. The conduit lost about 14% of its weight after 60 days in distilled water. The produced conduit enhanced the proliferation of SCs demonstrated by a tetrazolium salt-based assay. For functional analysis, the conduit was seeded with 1.50 × 10 4 SCs (PU/GNFs/PRP/MLT/SCs) and implanted into a 10-mm sciatic nerve defect of Wistar rat. Three control groups were used: (1) PU/GNFs/SCs, (2) PU/GNFs/PRP/SCs, and (3) Autograft. The results of sciatic functional index, hot plate latency, compound muscle action potential amplitude and latency, weight-loss percentage of wet gastrocnemius muscle and histopathological examination using hematoxylin-eosin and Luxol fast blue staining, demonstrated that using the PU/GNFs/PRP/MLT conduit to transplant SCs to the sciatic nerve defect resulted in a higher regenerative outcome than the PU/GNFs and PU/GNFs/PRP conduits.

  7. Liquid rocket valve components

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A monograph on valves for use with liquid rocket propellant engines is presented. The configurations of the various types of valves are described and illustrated. Design criteria and recommended practices for the various valves are explained. Tables of data are included to show the chief features of valve components in use on operational vehicles.

  8. Valve assembly for internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wakeman, R.J.; Shea, S.F.

    1989-09-05

    This patent describes an improvement in a valve assembly for an internal combustion engine of the type including a valve having a valve stem, a valve guideway for mounting this valve for reciprocal strokes between opened and seated position, and spring means for biasing the valve into the seated position. The improvement comprising a valve spool of greater cross-sectional diameter as compared to the valve stem, and a valve spool guideway within which the valve spool is movable during the strokes of the valve, an upper surface of the valve spool and a portion of the spool guideway collectively establishingmore » a damper chamber which varies in volume during the valve strokes. a feed passage for introducing oil into the damper chamber, and a bleed passage for discharging oil from the damper chamber. The bleed passages each laterally opening into the valve spool guideway.« less

  9. Transcatheter Aortic Valve Implantation: Experience with the CoreValve Device.

    PubMed

    Asgar, Anita W; Bonan, Raoul

    2012-01-01

    The field of transcatheter aortic valve implantation has been rapidly evolving. The Medtronic CoreValve first emerged on the landscape in 2004 with initial first human studies, and it is currently being studied in the Pivotal US trial. This article details the current experience with the self-expanding aortic valve with a focus on clinical results and ongoing challenges. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Device and method for measuring multi-phase fluid flow in a conduit using an elbow flow meter

    DOEpatents

    Ortiz, Marcos G.; Boucher, Timothy J.

    1997-01-01

    A system for measuring fluid flow in a conduit. The system utilizes pressure transducers disposed generally in line upstream and downstream of the flow of fluid in a bend in the conduit. Data from the pressure transducers is transmitted to a microprocessor or computer. The pressure differential measured by the pressure transducers is then used to calculate the fluid flow rate in the conduit. Control signals may then be generated by the microprocessor or computer to control flow, total fluid dispersed, (in, for example, an irrigation system), area of dispersal or other desired effect based on the fluid flow in the conduit.

  11. Sliding-gate valve

    DOEpatents

    Usnick, George B.; Ward, Gene T.; Blair, Henry O.; Roberts, James W.; Warner, Terry N.

    1979-01-01

    This invention is a novel valve of the slidable-gate type. The valve is designed especially for long-term use with highly abrasive slurries. The sealing surfaces of the gate are shielded by the valve seats when the valve is fully open or closed, and the gate-to-seat clearance is swept with an inflowing purge gas while the gate is in transit. A preferred form of the valve includes an annular valve body containing an annular seat assembly defining a flow channel. The seat assembly comprises a first seat ring which is slidably and sealably mounted in the body, and a second seat ring which is tightly fitted in the body. These rings cooperatively define an annular gap which, together with passages in the valve body, forms a guideway extending normal to the channel. A plate-type gate is mounted for reciprocation in the guideway between positions where a portion of the plate closes the channel and where a circular aperture in the gate is in register with the channel. The valve casing includes opposed chambers which extend outwardly from the body along the axis of the guideway to accommodate the end portions of the gate. The chambers are sealed from atmosphere; when the gate is in transit, purge gas is admitted to the chambers and flows inwardly through the gate-to-seat-ring, clearance, minimizing buildup of process solids therein. A shaft reciprocated by an external actuator extends into one of the sealed chambers through a shaft seal and is coupled to an end of the gate. Means are provided for adjusting the clearance between the first seat ring and the gate while the valve is in service.

  12. Solenoid Valve With Self-Compensation

    NASA Technical Reports Server (NTRS)

    Woeller, Fritz H.; Matsumoto, Yutaka

    1987-01-01

    New solenoid-operated miniature shutoff valve provides self-compensation of differential pressure forces that cause jamming or insufficient valve closure as in single-seal valves. Dual-seal valve is bidirectional. Valve simultaneously seals both inlet and outlet tubes by pressing single disk of silicone rubber against ends of both.

  13. Interactions of large amplitude solitary waves in viscous fluid conduits

    NASA Astrophysics Data System (ADS)

    Lowman, Nicholas K.; Hoefer, M. A.; El, G. A.

    2014-07-01

    The free interface separating an exterior, viscous fluid from an intrusive conduit of buoyant, less viscous fluid is known to support strongly nonlinear solitary waves due to a balance between viscosity-induced dispersion and buoyancy-induced nonlinearity. The overtaking, pairwise interaction of weakly nonlinear solitary waves has been classified theoretically for the Korteweg-de Vries equation and experimentally in the context of shallow water waves, but a theoretical and experimental classification of strongly nonlinear solitary wave interactions is lacking. The interactions of large amplitude solitary waves in viscous fluid conduits, a model physical system for the study of one-dimensional, truly dissipationless, dispersive nonlinear waves, are classified. Using a combined numerical and experimental approach, three classes of nonlinear interaction behavior are identified: purely bimodal, purely unimodal, and a mixed type. The magnitude of the dispersive radiation due to solitary wave interactions is quantified numerically and observed to be beyond the sensitivity of our experiments, suggesting that conduit solitary waves behave as "physical solitons." Experimental data are shown to be in excellent agreement with numerical simulations of the reduced model. Experimental movies are available with the online version of the paper.

  14. Geometry and Hydraulics of Englacial Conduits, Storglaciaren, Sweden

    NASA Astrophysics Data System (ADS)

    Fountain, A. G.; Schlichting, R.; Frodin, S.; Jacobel, R. W.

    2001-12-01

    Englacial conduits are the primary structure responsible for transporting surface water to the base of a glacier, where it supplies the subglacial hydraulic system and, in turn, affects glacier movement. Despite the well-known theoretical descriptions of englacial conduits, little direct evidence exists about their geometry and hydraulics. In July 2001, we initiated a field effort on Storglaciären, Sweden, to intersect englacial conduits by drilling into the glacier using a hot water drill. A companion project (Jacobel et al., this session) attempted to detect the englacial conduits using ground-penetrating radar. In a typical borehole, the water level remained at the surface while drilling through the impermeable ice. Once a connection was made, the water level dropped roughly 10 m and remained low despite continued water pumping. A small video camera was lowered, with attachments, to measure the geometry of the opening, and water flow speed. The water level in the hole provided a piezometric measure of the pressure. We drilled 22 holes at 3 separate locations and 17 (77%) connected englacially, the remaining 5 reached the bed without englacial connection, of which 2 drained at the bed. The geometry of the connections was highly irregular in cross-section with 1-2 cm openings, reminiscent of crevasse-like features rather than circular cross-sections as anticipated from the theoretical literature. Flow behavior was observed by tracking particle motion. The flow was complicated, in part by the inferred tangential intersection between the borehole and structure, and by the observed surging behavior. Flow speeds were low, on the order of 1 cm sec-1. Water level records from 3 different holes over several days exhibited highly correlated variations and large diurnal excursions. In contrast, records from holes drilled to the bed showed little variation. Based on these measurements, our conceptual picture of the englacial system is that of a sluggish flow system

  15. Study of multiple cycles valves

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1973-01-01

    A discussion is presented regarding valves which can be cycled repeatedly and are available from industry for application in the inlet system for the Pioneer Venus Probe mass spectrometer. Both solenoid type and latching type valves are considered. The study is divided into two principal areas: (1) preparation of a valve specification reflecting the requirements of the inlet system cyclic valves for the Pioneer Venus Probe mass spectrometer and the submittal of this specification to potential valve suppliers for their response and proposal; (2) preparation of a design layout of an optimum cyclic valve meeting all of the valve specification requirements.

  16. Magnetic Check Valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  17. Banking of cryopreserved heart valves in Europe: assessment of a 10-year operation in the European Homograft Bank (EHB).

    PubMed

    Goffin, Y A; Van Hoeck, B; Jashari, R; Soots, G; Kalmar, P

    2000-03-01

    in the left ventricular outflow tract (LVOT). Of the aortic valves, 732 were implanted in the LVOT and 266 in the RVOT. Mitral homografts were used for tricuspid valve replacement in two cases, and in the mitral position in seven. Complications at distribution and thawing included 10 bag ruptures and 16 transversal conduit wall fractures. Of the valves shipped, 317 (13.16%) were not used and were returned safely in the dry shipper. Comparison of distribution rates in the first 5.5 and last 4.5 years of EHB activity shows: (i) a significant increase in pulmonary valve implantations in the RVOT (from 71.95% to 81.95%); and (ii) a marked increase (265%) in pulmonary homograft implantations as part of a Ross operation, and a significant decrease (28%) in aortic homograft implantation in the LVOT. While macroscopic lesions of procured aortic valves remain the most frequent and unavoidable cause of homograft rejection during quality control, the high percentage of inadequate surgical heart valve excision should be corrected. The rates of bacterial contamination and positive serology seem acceptable. Storage and shipping of cryopreserved homografts in liquid nitrogen vapor permits them to be spared very efficiently. The increasing use of pulmonary valves for RVOT reconstruction either in congenital heart disease or as part of the Ross procedure compensates for the limited availability of good quality aortic valves.

  18. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    PubMed

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  19. Transcatheter Mitral Valve Replacement for Native and Failed Bioprosthetic Mitral Valves

    PubMed Central

    Sarkar, Kunal; Reardon, Michael J.; Little, Stephen H.; Barker, Colin M.; Kleiman, Neal S.

    2017-01-01

    Transcatheter mitral valve replacement (TMVR) is a novel approach for treatment of severe mitral regurgitation. A number of TMVR devices are currently undergoing feasibility trials using both transseptal and transapical routes for device delivery. Overall experience worldwide is limited to fewer than 200 cases. At present, the 30-day mortality exceeds 30% and is attributable to both patient- and device-related factors. TMVR has been successfully used to treat patients with degenerative mitral stenosis (DMS) as well as failed mitral bioprosthesis and mitral repair using transcatheter mitral valve-in-valve (TMViV)/valve-in-ring (ViR) repair. These patients are currently treated with devices designed for transcatheter aortic valve replacement. Multicenter registries have been initiated to collect outcomes data on patients currently undergoing TMViV/ViR and TMVR for DMS and have confirmed the feasibility of TMVR in these patients. However, the high periprocedural and 30-day event rates underscore the need for further improvements in device design and multicenter randomized studies to delineate the role of these technologies in patients with mitral valve disease. PMID:29743999

  20. Delineating saturated conduit patterns and dimensions in the upper Floridan aquifer through numerical groundwater flow modeling (Invited)

    NASA Astrophysics Data System (ADS)

    Kincaid, T. R.; Meyer, B. A.

    2009-12-01

    In groundwater flow modeling, aquifer permeability is typically defined through model calibration. Since the pattern and size of conduits are part of a karstic permeability framework, those parameters should be constrainable through the same process given a sufficient density of measured conditions. H2H Associates has completed a dual-permeability steady-state model of groundwater flow through the western Santa Fe River Basin, Florida from which a 380.9 km network of saturated conduits was delineated through model calibration to heads and spring discharges. Two calibration datasets were compiled describing average high-water and average low-water conditions based on heads at 145 wells and discharge from 18 springs for the high-water scenario and heads at 188 wells and discharge from 9 springs for the low-water scenario. An initial conduit network was defined by assigning paths along mapped conduits and inferring paths along potentiometric troughs between springs and swallets that had been connected by groundwater tracing. These initial conduit assignments accounted for only 13.75 and 34.1 km of the final conduit network respectively. The model was setup using FEFLOW™ where conduits were described as discrete features embedded in a porous matrix. Flow in the conduits was described by the Manning-Strickler equation where variables for conduit area and roughness were used to adjust the volume and velocity of spring flows. Matrix flow was described by Darcy’s law where hydraulic conductivity variations were limited to three geologically defined internally homogeneous zones that ranged from ~2E-6 m/s to ~4E-3 m/s. Recharge for both the high-water and low-water periods was determined through a water budget analysis where variations were restricted to nine zones defined by land-use. All remaining variations in observed head were then assumed to be due to conduits. The model was iteratively calibrated to the high-water and low-water datasets wherein the location, size

  1. 26 CFR 1.7701(l)-1 - Conduit financing arrangements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... determines that such recharacterization is appropriate to prevent avoidance of any tax imposed by title 26 of...) INCOME TAX (CONTINUED) INCOME TAXES General Actuarial Valuations § 1.7701(l)-1 Conduit financing...

  2. Conical Seat Shut-Off Valve

    NASA Technical Reports Server (NTRS)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  3. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, J.A.

    1980-05-16

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  4. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, James A.

    1982-01-01

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  5. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    PubMed

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  6. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis

    PubMed Central

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Objective Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Methods Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. Results A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). Conclusion The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in

  7. Device and method for measuring multi-phase fluid flow in a conduit using an elbow flow meter

    DOEpatents

    Ortiz, M.G.; Boucher, T.J.

    1997-06-24

    A system is described for measuring fluid flow in a conduit. The system utilizes pressure transducers disposed generally in line upstream and downstream of the flow of fluid in a bend in the conduit. Data from the pressure transducers is transmitted to a microprocessor or computer. The pressure differential measured by the pressure transducers is then used to calculate the fluid flow rate in the conduit. Control signals may then be generated by the microprocessor or computer to control flow, total fluid dispersed, (in, for example, an irrigation system), area of dispersal or other desired effect based on the fluid flow in the conduit. 2 figs.

  8. Heart valve surgery - series (image)

    MedlinePlus

    ... heart valves are either natural (biologic) or artificial (mechanical). Natural valves are from human donors (cadavers), modified ... artificial valves will require anticoagulation. The advantage of mechanical valves is that they last longer-thus, the ...

  9. Valve Repair or Replacement

    MedlinePlus

    ... called anticoagulants) for the rest of their lives. Biological valves are made from animal tissue (called a ... for valve replacement (called an autograft). Patients with biological valves usually do not need to take blood- ...

  10. Human Fetal Testis Xenografts Are Resistant to Phthalate-Induced Endocrine Disruption

    PubMed Central

    Heger, Nicholas E; Hall, Susan J; Sandrof, Moses A; McDonnell, Elizabeth V; Hensley, Janan B; McDowell, Erin N; Martin, Kayla A; Gaido, Kevin W; Johnson, Kamin J

    2012-01-01

    Background: In utero exposure to endocrine-disrupting chemicals may contribute to testicular dysgenesis syndrome (TDS), a proposed constellation of increasingly common male reproductive tract abnormalities (including hypospadias, cryptorchidism, hypospermatogenesis, and testicular cancer). Male rats exposed in utero to certain phthalate plasticizers exhibit multinucleated germ cell (MNG) induction and suppressed steroidogenic gene expression and testosterone production in the fetal testis, causing TDS-consistent effects of hypospadias and cryptorchidism. Mice exposed to phthalates in utero exhibit MNG induction only. This disparity in response demonstrates a species-specific sensitivity to phthalate-induced suppression of fetal Leydig cell steroidogenesis. Importantly, ex vivo phthalate exposure of the fetal testis does not recapitulate the species-specific endocrine disruption, demonstrating the need for a new bioassay to assess the human response to phthalates. Objectives: In this study, we aimed to develop and validate a rat and mouse testis xenograft bioassay of phthalate exposure and examine the human fetal testis response. Methods: Fetal rat, mouse, and human testes were xenografted into immunodeficient rodent hosts, and hosts were gavaged with a range of phthalate doses over multiple days. Xenografts were harvested and assessed for histopathology and steroidogenic end points. Results: Consistent with the in utero response, phthalate exposure induced MNG formation in rat and mouse xenografts, but only rats exhibited suppressed steroidogenesis. Across a range of doses, human fetal testis xenografts exhibited MNG induction but were resistant to suppression of steroidogenic gene expression. Conclusions: Phthalate exposure of grafted human fetal testis altered fetal germ cells but did not reduce expression of genes that regulate fetal testosterone biosynthesis. PMID:22511013

  11. Fluid mechanics of heart valves.

    PubMed

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  12. Intelligent Flow Control Valve

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  13. How to Make a Heart Valve: From Embryonic Development to Bioengineering of Living Valve Substitutes

    PubMed Central

    MacGrogan, Donal; Luxán, Guillermo; Driessen-Mol, Anita; Bouten, Carlijn; Baaijens, Frank; de la Pompa, José Luis

    2014-01-01

    Cardiac valve disease is a significant cause of ill health and death worldwide, and valve replacement remains one of the most common cardiac interventions in high-income economies. Despite major advances in surgical treatment, long-term therapy remains inadequate because none of the current valve substitutes have the potential for remodeling, regeneration, and growth of native structures. Valve development is coordinated by a complex interplay of signaling pathways and environmental cues that cause disease when perturbed. Cardiac valves develop from endocardial cushions that become populated by valve precursor mesenchyme formed by an epithelial–mesenchymal transition (EMT). The mesenchymal precursors, subsequently, undergo directed growth, characterized by cellular compartmentalization and layering of a structured extracellular matrix (ECM). Knowledge gained from research into the development of cardiac valves is driving exploration into valve biomechanics and tissue engineering directed at creating novel valve substitutes endowed with native form and function. PMID:25368013

  14. Constraints on the Geometries and Compositions of Subvolcanic Conduits from Intrusions of the San Rafael Swell, Utah

    NASA Astrophysics Data System (ADS)

    Wetmore, P. H.; Connor, C.; Wilson, J.

    2010-12-01

    Conduit models incorporate varying degrees of complexity (or parsimony) and account for the transport properties of magmas, steady-state or transient behavior, and conduit geometry (e.g., 1- to 1.5 D, variable width and erodable conduit walls). Improvement of these models is important if we are to work toward deployment of eruption models at active volcanoes, link these models to geophysical observations (seismic, deformation, gravity) and eventually forecast eruption magnitude. One conclusion of a recent comparison of many conduit models (Sahagian, 2005 JVGR) is that next generation models need to better account for interaction of the erupting mixture with surrounding wall rocks (accounting for melting, solidification, and erosion) and better account for the effects of conduit shape on flows. In an effort to address these issues our research group has completed mapping of a suite of subvolcanic intrusions (dikes, sills, and conduits) from the west-central San Rafael Swell of central Utah. The results of this study demonstrate that vertical flow of melt through crust in this system of intrusion was dominated by dikes. Conduits form, in nearly all cases, as a result of localized flow along dikes. The conduits are commonly comprised of three distinct lithologic units: brecciated host rock (without any intrusive material), brecciated host rock mixed with brecciated and mechanically contaminated intrusive, and relatively clean (i.e. containing less than ~10% accidental material) intrusive. Contacts between all three of these units are typically discreet and traceable for several tens of meters. In some examples clasts within the unmixed breccia unit exhibit a strong alignment of clasts dipping into the core of the conduit. These observations suggests an evolutionary history that involves an early phase of brecciation and mixing, followed by confined flow with a fluidized mixed unit and an essentially uninvolved outer zone (i.e. the breccia). The final phase likely

  15. A Linearized Model for Wave Propagation through Coupled Volcanic Conduit-crack Systems Filled with Multiphase Magma

    NASA Astrophysics Data System (ADS)

    Liang, C.; Dunham, E. M.; OReilly, O. J.; Karlstrom, L.

    2015-12-01

    Both the oscillation of magma in volcanic conduits and resonance of fluid-filled cracks (dikes and sills) are appealing explanations for very long period signals recorded at many active volcanoes. While these processes have been studied in isolation, real volcanic systems involve interconnected networks of conduits and cracks. The overall objective of our work is to develop a model of wave propagation and ultimately eruptive fluid dynamics through this coupled system. Here, we present a linearized model for wave propagation through a conduit with multiple cracks branching off of it. The fluid is compressible and viscous, and is comprised of a mixture of liquid melt and gas bubbles. Nonequilibrium bubble growth and resorption (BGR) is quantified by introducing a time scale for mass exchange between phases, following the treatment in Karlstrom and Dunham (2015). We start by deriving the dispersion relation for crack waves travelling along the multiphase-magma-filled crack embedded in an elastic solid. Dissipation arises from magma viscosity, nonequilibrium BGR, and radiation of seismic waves into the solid. We next introduce coupling conditions between the conduit and crack, expressing conservation of mass and the balance of forces across the junction. Waves in the conduit, like those in the crack, are influenced by nonequilibrium BGR, but the deformability of the surrounding solid is far less important than for cracks. Solution of the coupled system of equations provides the evolution of pressure and fluid velocity within the conduit-crack system. The system has various resonant modes that are sensitive to fluid properties and to the geometry of the conduit and cracks. Numerical modeling of seismic waves in the solid allows us to generate synthetic seismograms.

  16. Challenges of using electrical resistivity method to locate karst conduits-A field case in the Inner Bluegrass Region, Kentucky

    USGS Publications Warehouse

    Zhu, J.; Currens, J.C.; Dinger, J.S.

    2011-01-01

    Conduits serve as major pathways for groundwater flow in karst aquifers. Locating them from the surface, however, is one of the most challenging tasks in karst research. Geophysical methods are often deployed to help locate voids by mapping variations of physical properties of the subsurface. Conduits can cause significant contrasts of some physical properties that can be detected; other subsurface features such as water-bearing fractures often yield similar contrasts, which are difficult to distinguish from the effects of the conduits. This study used electrical resistivity method to search for an unmapped karst conduit that recharges Royal Spring in the Inner Bluegrass karst region, Kentucky, USA. Three types of resistivity techniques (surface 2D survey, quasi-3D survey, and time-lapse survey) were used to map and characterize resistivity anomalies. Some of the major anomalies were selected as drilling targets to verify the existence of the conduits. Drilling near an anomaly identified by an electrical resistivity profile resulted in successful penetration of a major water-filled conduit. The drilling results also suggest that, in this study area, low resistivity anomalies in general are associated with water-bearing features. However, differences in the anomaly signals between the water-filled conduit and other water-bearing features such as water-filled fracture zones were undistinguishable. The electrical resistivity method is useful in conduit detection by providing potential drilling targets. Knowledge of geology and hydrogeology about the site and professional judgment also played important roles in locating the major conduit. ?? 2011 Elsevier B.V.

  17. Locking apparatus for gate valves

    DOEpatents

    Fabyan, J.; Williams, C.W.

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing further movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  18. Long life valve design concepts

    NASA Technical Reports Server (NTRS)

    Jones, J. R.; Hall, A. H., Jr.

    1975-01-01

    Valve concept evaluation, final candidate selection, design, manufacture, and demonstration testing of a pneumatically actuated 10-inch hybrid poppet butterfly shutoff valve are presented. Conclusions and recommendations regarding those valve characteristics and features which would serve to guide in the formulation of future valve procurements are discussed. The pertinent design goals were temperature range of plus 200 to minus 423 F, valve inlet pressure 35 psia, actuation pressure 750 psia, main seal leakage 3 x 0.00001 sccs at 35 psia valve inlet pressure, and a storage and operating life of 10 years. The valve was designed to be compatible with RP-1, propane, LH2, LO2, He, and N2.

  19. Genipin-Cross-Linked Chitosan Nerve Conduits Containing TNF-α Inhibitors for Peripheral Nerve Repair.

    PubMed

    Zhang, Li; Zhao, Weijia; Niu, Changmei; Zhou, Yujie; Shi, Haiyan; Wang, Yalin; Yang, Yumin; Tang, Xin

    2018-07-01

    Tissue engineered nerve grafts (TENGs) are considered a promising alternative to autologous nerve grafting, which is considered the "gold standard" clinical strategy for peripheral nerve repair. Here, we immobilized tumor necrosis factor-α (TNF-α) inhibitors onto a nerve conduit, which was introduced into a chitosan (CS) matrix scaffold utilizing genipin (GP) as the crosslinking agent, to fabricate CS-GP-TNF-α inhibitor nerve conduits. The in vitro release kinetics of TNF-α inhibitors from the CS-GP-TNF-α inhibitor nerve conduits were investigated using high-performance liquid chromatography. The in vivo continuous release profile of the TNF-α inhibitors released from the CS-GP-TNF-α inhibitor nerve conduits was measured using an enzyme-linked immunosorbent assay over 14 days. We found that the amount of TNF-α inhibitors released decreased with time after the bridging of the sciatic nerve defects in rats. Moreover, 4 and 12 weeks after surgery, histological analyses and functional evaluations were carried out to assess the influence of the TENG on regeneration. Immunochemistry performed 4 weeks after grafting to assess early regeneration outcomes revealed that the TENG strikingly promoted axonal outgrowth. Twelve weeks after grafting, the TENG accelerated myelin sheath formation, as well as functional restoration. In general, the regenerative outcomes following TENG more closely paralleled findings observed with autologous grafting than the use of the CS matrix scaffold. Collectively, our data indicate that the CS-GP-TNF-α inhibitor nerve conduits comprised an elaborate system for sustained release of TNF-α inhibitors in vitro, while studies in vivo demonstrated that the TENG could accelerate regenerating axonal outgrowth and functional restoration. The introduction of CS-GP-TNF-α-inhibitor nerve conduits into a scaffold may contribute to an efficient and adaptive immune microenvironment that can be used to facilitate peripheral nerve repair.

  20. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    PubMed

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no

  1. Device and method for measuring multi-phase fluid flow and density of fluid in a conduit having a gradual bend

    DOEpatents

    Ortiz, Marcos German; Boucher, Timothy J.

    1998-01-01

    A system for measuring fluid flow in a conduit having a gradual bend or arc, and a straight section. The system includes pressure transducers, one or more disposed in the conduit on the outside of the arc, and one disposed in the conduit in a straight section thereof. The pressure transducers measure the pressure of fluid in the conduit at the locations of the pressure transducers and this information is used by a computational device to calculate fluid flow rate in the conduit. For multi-phase fluid, the density of the fluid is measured by another pair of pressure transducers, one of which is located in the conduit elevationally above the other. The computation device then uses the density measurement along with the fluid pressure measurements, to calculate fluid flow.

  2. Device and method for measuring multi-phase fluid flow and density of fluid in a conduit having a gradual bend

    DOEpatents

    Ortiz, M.G.; Boucher, T.J.

    1998-10-27

    A system is described for measuring fluid flow in a conduit having a gradual bend or arc, and a straight section. The system includes pressure transducers, one or more disposed in the conduit on the outside of the arc, and one disposed in the conduit in a straight section thereof. The pressure transducers measure the pressure of fluid in the conduit at the locations of the pressure transducers and this information is used by a computational device to calculate fluid flow rate in the conduit. For multi-phase fluid, the density of the fluid is measured by another pair of pressure transducers, one of which is located in the conduit elevationally above the other. The computation device then uses the density measurement along with the fluid pressure measurements, to calculate fluid flow. 1 fig.

  3. Conduit margin heating and deformation during the AD 1886 basaltic Plinian eruption at Tarawera volcano, New Zealand.

    PubMed

    Schauroth, Jenny; Wadsworth, Fabian B; Kennedy, Ben; von Aulock, Felix W; Lavallée, Yan; Damby, David E; Vasseur, Jérémie; Scheu, Bettina; Dingwell, Donald B

    During explosive eruptions, a suspension of gas and pyroclasts rises rapidly within a conduit. Here, we have analysed textures preserved in the walls of a pyroclastic feeder dyke of the AD 1886 Tarawera basaltic Plinian fissure eruption. The samples examined consist of basaltic ash and scoria plastered onto a conduit wall of a coherent rhyolite dome and a welded rhyolitic dome breccia. We examine the textural evidence for the response of the wall material, built of ∼75 vol.% glass and ∼25 vol.% crystals (pore-free equivalent), to mass movement in the adjacent conduit. In the rhyolitic wall material, we quantify the orientation and aspect ratio of biotite crystals as strain markers of simple shear deformation, and interpret juxtaposed regions of vesiculation and vesicle collapse as evidence of conduit wall heating. Systematic changes occur close to the margin: (1) porosity is highly variable, with areas locally vesiculated or densified, (2) biotite crystals are oriented with their long axis parallel to the margin, (3) the biotites have greater aspect ratios close to the margin and (4) the biotite crystals are fractured. We interpret the biotite phenocryst deformation to result from crystal fracture, rotation and cleavage-parallel bookcase translation. These textural observations are inferred to indicate mechanical coupling between the hot gas-ash jet and the conduit wall and reheating of wall rock rhyolite. We couple these observations with a simple 1D conductive heating model to show what minimum temperature the conduit wall needs to reach in order to achieve a temperature above the glass transition throughout the texturally-defined deformed zone. We propose that conduit wall heating and resulting deformation influences conduit margin outgassing and may enhance the intensity of such large basaltic eruptions.

  4. Compact valve actuation mechanism

    NASA Technical Reports Server (NTRS)

    Brogdon, James William (Inventor); Gill, David Keith (Inventor)

    2000-01-01

    A valve actuation device. The device may include a free floating valve bridge movably supported within a cavity in the engine housing. The bridge may be provided with a cavity and an orifice arrangement for pumping gases entrained with lubricating fluid toward the piston stems as the bridge reciprocates back and forth. The device may also include a rocker arm that has a U-shaped cross-sectional shape for receiving at least a portion of the valve bridge, valve stem valve spring and spring retainer therein. The rocker arm may be provided with lubrication passages for directing lubrication to the point wherein it is pivotally affixed to the engine housing.

  5. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  6. Fluid mechanics of artificial heart valves.

    PubMed

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  7. Improved mitral valve coaptation and reduced mitral valve annular size after percutaneous mitral valve repair (PMVR) using the MitraClip system.

    PubMed

    Patzelt, Johannes; Zhang, Yingying; Magunia, Harry; Ulrich, Miriam; Jorbenadze, Rezo; Droppa, Michal; Zhang, Wenzhong; Lausberg, Henning; Walker, Tobias; Rosenberger, Peter; Seizer, Peter; Gawaz, Meinrad; Langer, Harald F

    2017-08-01

    Improved mitral valve leaflet coaptation with consecutive reduction of mitral regurgitation (MR) is a central goal of percutaneous mitral valve repair (PMVR) with the MitraClip® system. As influences of PMVR on mitral valve geometry have been suggested before, we examined the effect of the procedure on mitral annular size in relation to procedural outcome. Geometry of the mitral valve annulus was evaluated in 183 patients undergoing PMVR using echocardiography before and after the procedure and at follow-up. Mitral valve annular anterior-posterior (ap) diameter decreased from 34.0 ± 4.3 to 31.3 ± 4.9 mm (P < 0.001), and medio-lateral (ml) diameter from 33.2 ± 4.8 to 32.4 ± 4.9 mm (P < 0.001). Accordingly, we observed an increase in MV leaflet coaptation after PMVR. The reduction of mitral valve ap diameter showed a significant inverse correlation with residual MR. Importantly, the reduction of mitral valve ap diameter persisted at follow-up (31.3 ± 4.9 mm post PMVR, 28.4 ± 5.3 mm at follow-up). This study demonstrates mechanical approximation of both mitral valve annulus edges with improved mitral valve annular coaptation by PMVR using the MitraClip® system, which correlates with residual MR in patients with MR. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  8. Valve technology: A compilation

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A technical compilation on the types, applications and modifications to certain valves is presented. Data cover the following: (1) valves that feature automatic response to stimuli (thermal, electrical, fluid pressure, etc.), (2) modified valves changed by redesign of components to increase initial design effectiveness or give the item versatility beyond its basic design capability, and (3) special purpose valves with limited application as presented, but lending themselves to other uses with minor changes.

  9. A Real-Time Non-invasive Auto-bioluminescent Urinary Bladder Cancer Xenograft Model.

    PubMed

    John, Bincy Anu; Xu, Tingting; Ripp, Steven; Wang, Hwa-Chain Robert

    2017-02-01

    The study was to develop an auto-bioluminescent urinary bladder cancer (UBC) xenograft animal model for pre-clinical research. The study used a humanized, bacteria-originated lux reporter system consisting of six (luxCDABEfrp) genes to express components required for producing bioluminescent signals in human UBC J82, J82-Ras, and SW780 cells without exogenous substrates. Immune-deficient nude mice were inoculated with Lux-expressing UBC cells to develop auto-bioluminescent xenograft tumors that were monitored by imaging and physical examination. Lux-expressing auto-bioluminescent J82-Lux, J82-Ras-Lux, and SW780-Lux cell lines were established. Xenograft tumors derived from tumorigenic Lux-expressing auto-bioluminescent J82-Ras-Lux cells allowed a serial, non-invasive, real-time monitoring by imaging of tumor development prior to the presence of palpable tumors in animals. Using Lux-expressing auto-bioluminescent tumorigenic cells enabled us to monitor the entire course of xenograft tumor development through tumor cell implantation, adaptation, and growth to visible/palpable tumors in animals.

  10. Exploring Ultimate Water Capillary Evaporation in Nanoscale Conduits.

    PubMed

    Li, Yinxiao; Alibakhshi, Mohammad Amin; Zhao, Yihong; Duan, Chuanhua

    2017-08-09

    Capillary evaporation in nanoscale conduits is an efficient heat/mass transfer strategy that has been widely utilized by both nature and mankind. Despite its broad impact, the ultimate transport limits of capillary evaporation in nanoscale conduits, governed by the evaporation/condensation kinetics at the liquid-vapor interface, have remained poorly understood. Here we report experimental study of the kinetic limits of water capillary evaporation in two dimensional nanochannels using a novel hybrid channel design. Our results show that the kinetic-limited evaporation fluxes break down the limits predicated by the classical Hertz-Knudsen equation by an order of magnitude, reaching values up to 37.5 mm/s with corresponding heat fluxes up to 8500 W/cm 2 . The measured evaporation flux increases with decreasing channel height and relative humidity but decreases as the channel temperature decreases. Our findings have implications for further understanding evaporation at the nanoscale and developing capillary evaporation-based technologies for both energy- and bio-related applications.

  11. Colorectal cancer patient-derived xenografted tumors maintain characteristic features of the original tumors.

    PubMed

    Cho, Yong Beom; Hong, Hye Kyung; Choi, Yoon-La; Oh, Ensel; Joo, Kyeung Min; Jin, Juyoun; Nam, Do-Hyun; Ko, Young-Hyeh; Lee, Woo Yong

    2014-04-01

    Despite significant improvements in colon cancer outcomes over the past few decades, preclinical development of more effective therapeutic strategies is still limited by the availability of clinically relevant animal models. To meet those clinical unmet needs, we generated a well-characterized in vivo preclinical platform for colorectal cancer using fresh surgical samples. Primary and metastatic colorectal tumor tissues (1-2 mm(3)) that originate from surgery were implanted into the subcutaneous space of nude mice and serially passaged in vivo. Mutation status, hematoxylin and eosin staining, short tandem repeat profiling, and array comparative genomic hybridization were used to validate the similarity of molecular characteristics between the patient tumors and tumors obtained from xenografts. From surgical specimens of 143 patients, 97 xenograft models were obtained in immunodeficient mice (establish rate = 67%). Thirty-nine xenograft models were serially expanded further in mice with a mean time to reach a size of 1000-1500 mm(3) of 90 ± 20 d. Histologic and immunohistochemical analyses revealed a high degree of pathologic similarity including histologic architecture and expression of CEA, CK7, and CD20 between the patient and xenograft tumors. Molecular analysis showed that genetic mutations, genomic alterations, and gene expression patterns of each patient tumor were also well conserved in the corresponding xenograft tumor. Xenograft animal models derived from fresh surgical sample maintained the key characteristic features of the original tumors, suggesting that this in vivo platform can be useful for preclinical development of novel therapeutic approaches to colorectal cancers. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Comparison of acute elastic recoil between the SAPIEN-XT and SAPIEN valves in transfemoral-transcatheter aortic valve replacement.

    PubMed

    Garg, Aatish; Parashar, Akhil; Agarwal, Shikhar; Aksoy, Olcay; Hammadah, Muhammad; Poddar, Kanhaiya Lal; Puri, Rishi; Svensson, Lars G; Krishnaswamy, Amar; Tuzcu, E Murat; Kapadia, Samir R

    2015-02-15

    The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.

  13. Technical pitfalls and tips for the valve-in-valve procedure

    PubMed Central

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these

  14. Valve stem and packing assembly

    DOEpatents

    Wordin, John J.

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  15. Valve stem and packing assembly

    DOEpatents

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  16. Self-Rupturing Hermetic Valve

    NASA Technical Reports Server (NTRS)

    Tucker, Curtis E., Jr.; Sherrit, Stewart

    2011-01-01

    For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self

  17. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    PubMed

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p < 0.0001), tricuspid valve regurgitation (mean 2.33 vs 1.3, p < 0.0001), and in right ventricular dilation, volume, and area. There was no difference in the degree of tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve

  18. Thermo-Hydraulic Characteristics of Anatase Titania Nanofluids Flowing Through a Circular Conduit.

    PubMed

    Kristiawan, Budi; Kamal, Samsul; Yanuar

    2016-06-01

    The thermo-hydraulic characteristics of anatase titanium dioxide dispersed into distilled water with particle concentration of 0.1, 0.3, and 0.5 vol.% were investigated experimentally in this work. The influence of rheological behavior on hydrodynamic and convective heat transfer characteristics was evaluated under both laminar and turbulent flow conditions in a plain conduit and with twisted tape insert for twist ratio of 7. The nanofluids exhibited a strong shear-thinning behavior at low shear rate particularly higher particle concentration. The non-Newtonian titania nanofluids have also demonstrated a drag reduction phenomena in turbulent flow. At equal Reynolds number, the values of performance evaluation criterion in a conduit inserted a twisted tape were lower than those of in a plain conduit. It implies the unfavourable energy budget for twisted tape insert. The convective heat transfer coefficient does not gradually enhance with an increase of particle concentration. The flow features due mainly to the rheology of colloidal dispersions might be a reason for this phenomenon.

  19. 26 CFR 1.881-3 - Conduit financing arrangements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... satisfaction of a repayment obligation is not an advance of money or other property. A financing arrangement... facts and circumstances, including, without limitation, the factors set forth in paragraph (b)(2) of..., will not affect the determinations made pursuant to this paragraph (a)(2)(ii)(B). (iii) Conduit entity...

  20. Slide valve apparatus for internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, B.A.; McMahan, T.O.

    This patent describes an internal combustion engine including a combustion cylinder having an opening at one end thereof, a piston mounted within the cylinder for coaxial reciprocable movement, a driven crankshaft, and a connecting rod connecting the crankshaft to the cylinder for linear reciprocable movement of the piston in response to the rotary movement of the crankshaft, a valve apparatus comprising: (a) a valve chamber extending longitudinally across and in fluid communication with the opening in the cylinder, (b) an intake valve plate having a longitudinal axis mounted within the valve chamber for slidable, reciprocable, longitudinal movement, (c) an exhaustmore » valve plate having a longitudinal axis mounted within the valve chamber alongside the intake valve plate for slidable, reciprocable, longitudinal movement and parallel to the longitudinal axis of the intake valve plate, (d) each of the valve plates having a plurality of longitudinally spaced valve ports therein, the valve ports comprising movable intake valve ports in the intake valve plate and movable exhaust valve ports in the exhaust valve plate, (e) the valve chamber comprising a planar wall on the opposite side of the valve plates from the cylinder opening and having a plurality of fixed valve ports therethrough. The fixed valve ports being equal in number and substantially equal in size and spacing as the movable intake and exhaust valve ports, whereby the movable intake valve ports are adapted to register with their corresponding fixed valve ports when the intake valve plate is in its intake operative position for opening fluid communication between the cylinder and the corresponding fixed valve ports.« less

  1. Lock For Valve Stem

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.; Guirguis, Kamal S.

    1991-01-01

    Simple, cheap device locks valve stem so its setting cannot be changed by unauthorized people. Device covers valve stem; cover locked in place with standard padlock. Valve lock made of PVC pipe and packing band. Shears, drill or punch, and forming rod only tools needed.

  2. Novel drug delivering conduit for peripheral nerve regeneration

    NASA Astrophysics Data System (ADS)

    Labroo, Pratima; Shea, Jill; Edwards, Kyle; Ho, Scott; Davis, Brett; Sant, Himanshu; Goodwin, Isak; Gale, Bruce; Agarwal, Jay

    2017-12-01

    Objective. This paper describes the design of a novel drug delivery apparatus integrated with a poly lactic-co-glycolic acid (PLGA) based nerve guide conduit for controlled local delivery of nerve growth factor (NGF) and application in peripheral nerve gap injury. Approach. An NGF dosage curve was acquired to determine the minimum in vitro concentration for optimal neurite outgrowth of dorsal root ganglion (DRG) cells; PLGA based drug delivery devices were then designed and tested in vitro and in vivo across 15 mm rat sciatic nerve gap injury model. Main results. The drug delivery nerve guide was able to release NGF for 28 d at concentrations (0.1-10 ng ml-1) that were shown to enhance DRG neurite growth. Furthermore, the released NGF was bioactive and able to enhance DRG neurite growth. Following these tests, optimized NGF-releasing nerve conduits were implanted across 15 mm sciatic nerve gaps in a rat model, where they demonstrated significant myelination and muscle innervation in vivo as compared to empty nerve conduits (p  <  0.05). This drug delivery nerve guide can release NGF for extended periods of time and enhance axon growth in vitro and in vivo and has the potential to improve nerve regeneration following a peripheral nerve injury. Significance. This integrated drug delivering nerve guide simplifies the design process and provides increased versatility for releasing a variety of different growth factors. This innovative device has the potential for broad applicability and allows for easier customization to change the type of drugs and dosage of individual drugs without devising a completely new biomaterial-drug conjugate each time.

  3. A Physicochemically Optimized and Neuroconductive Biphasic Nerve Guidance Conduit for Peripheral Nerve Repair.

    PubMed

    Ryan, Alan J; Lackington, William A; Hibbitts, Alan J; Matheson, Austyn; Alekseeva, Tijna; Stejskalova, Anna; Roche, Phoebe; O'Brien, Fergal J

    2017-12-01

    Clinically available hollow nerve guidance conduits (NGCs) have had limited success in treating large peripheral nerve injuries. This study aims to develop a biphasic NGC combining a physicochemically optimized collagen outer conduit to bridge the transected nerve, and a neuroconductive hyaluronic acid-based luminal filler to support regeneration. The outer conduit is mechanically optimized by manipulating crosslinking and collagen density, allowing the engineering of a high wall permeability to mitigate the risk of neuroma formation, while also maintaining physiologically relevant stiffness and enzymatic degradation tuned to coincide with regeneration rates. Freeze-drying is used to seamlessly integrate the luminal filler into the conduit, creating a longitudinally aligned pore microarchitecture. The luminal stiffness is modulated to support Schwann cells, with laminin incorporation further enhancing bioactivity by improving cell attachment and metabolic activity. Additionally, this biphasic NGC is shown to support neurogenesis and gliogenesis of neural progenitor cells and axonal outgrowth from dorsal root ganglia. These findings highlight the paradigm that a successful NGC requires the concerted optimization of both a mechanical support phase capable of bridging a nerve defect and a neuroconductive phase with an architecture capable of supporting both Schwann cells and neurons in order to achieve functional regenerative outcome. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Temporal morphologic changes in human colorectal carcinomas following xenografting.

    PubMed Central

    Barkla, D. H.; Tutton, P. J.

    1983-01-01

    The temporal morphologic changes of human colorectal carcinomas following xenografting into immunosuppressed mice were investigated by the use of light and transmission electron microscopy. The results show that colorectal carcinomas undergo a series of morphologic changes during the initial 30-day period following transplantation. During the initial 1-5-day period the majority of tumor cells die, and during the following 5-10-day period the necrotic debris created during the 1-5-day period is removed by host-supplied inflammatory cells. Only small groups of peripherally placed tumor cells survived at the end of the first 10 days. During the 10-20-day period the tumor cell populations of xenografts were reestablished by a morphologically heterogeneous population of tumor cells, and during the 20-30 day period consolidation of this process continued and some xenografts showed macroscopic evidence of growth. The authors hypothesize that human colorectal carcinomas, like the antecedent epithelium, contain subpopulations of undifferentiated cells that give rise to populations of more-differentiated cells. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 PMID:6829710

  5. Design and development of a large diameter high pressure fast acting propulsion valve and valve actuator

    NASA Technical Reports Server (NTRS)

    Srinivasan, K. V.

    1986-01-01

    The design and development of a large diameter high pressure quick acting propulsion valve and valve actuator is described. The valve is the heart of a major test facility dedicated to conducting full scale performance tests of aircraft landing systems. The valve opens in less than 300 milliseconds releasing a 46-centimeter- (18-in.-) diameter water jet and closes in 300 milliseconds. The four main components of the valve, i.e., valve body, safety shutter, high speed shutter, and pneumatic-hydraulic actuator, are discussed. This valve is unique and may have other aerospace and industrial applications.

  6. Design and Development of a Large Diameter, High Pressure, Fast Acting Propulsion Valve and Valve Actuator

    NASA Technical Reports Server (NTRS)

    Srinivasan, K. V.

    1986-01-01

    This paper describes the design and development of a large diameter high pressure quick acting propulsion valve and valve actuator. The valve is the heart of a major test facility dedicated to conducting full scale performance tests of aircraft landing gear systems. The valve opens in less than 300 milliseconds releasing a 46 cm (18 in) diameter water jet and closes in 300 milliseconds. The four main components of the valve, i.e., valve body, safety shutter, high speed shutter, and pneumatic-hydraulic actuator, are discussed. This valve is unique and may have other aerospace and industrial applications.

  7. 78 FR 68052 - Town of Telluride, Colorado; Notice of Preliminary Determination of a Qualifying Conduit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-13

    ...--Criteria for Qualifying Conduit Hydropower Facility Satisfies (Y/ Statutory provision Description N) FPA 30(a)(3)(A), as amended by The conduit the Y HREA. facility uses is a tunnel, canal, pipeline, aqueduct... agricultural, municipal, or industrial consumption and not primarily for the generation of electricity. FPA 30...

  8. 78 FR 61987 - Corbett Water District; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-09

    ...), as amended by HREA.... The facility is constructed, operated, or maintained Y for the generation of... Conduit Hydropower Facility Satisfies (Y/ Statutory provision Description N) FPA 30(a)(3)(A), as amended by HREA....... The conduit the facility uses is a tunnel, canal, Y pipeline, aqueduct, flume, ditch...

  9. Evaluation of Cytarabine Against Ewing Sarcoma Xenografts by the Pediatric Preclinical Testing Program

    PubMed Central

    Houghton, Peter J.; Morton, Christopher L.; Kang, Min; Reynolds, C. Patrick; Billups, Catherine A.; Favours, Edward; Payne-Turner, Debbie; Tucker, Chandra; Smith, Malcolm A.

    2015-01-01

    Treatment with the nucleoside analog cytarabine has been shown to mimic changes in gene expression associated with down-regulation of the EWS-FLI1 oncogene in Ewing sarcoma cell lines, selectively inhibit their growth in vitro, and cause tumor regression in athymic nude mice. For this report cytarabine was studied in vitro against a panel of 23 pediatric cancer cell lines and in vivo against 6 Ewing sarcoma xenografts. Acute lymphoblastic leukemia cell lines were the most sensitive to cytarabine in vitro (median IC50 9 nM), while Ewing sarcoma cell lines showed intermediate sensitivity (median IC50 232 nM). Cytarabine at a dose of 150 mg/kg administered daily 5× failed to significantly inhibit growth of five xenograft models, but reduced growth rate of the A673 xenograft by 50%. Cytarabine shows no differential in vitro activity against Ewing sarcoma cell lines and is ineffective in vivo against Ewing sarcoma xenografts at the dose and schedule studied. PMID:20979180

  10. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    PubMed

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  11. 9. BUTTERFLY VALVE CONTROL DIABLO POWERHOUSE. BUTTERFLY VALVES WERE MANUFACTURED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. BUTTERFLY VALVE CONTROL DIABLO POWERHOUSE. BUTTERFLY VALVES WERE MANUFACTURED BY THE PELTON WATER WHEEL COMPANY IN 1931, 1989. - Skagit Power Development, Diablo Powerhouse, On Skagit River, 6.1 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  12. Pregnancy-induced remodeling of heart valves.

    PubMed

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves. Copyright © 2015 the American Physiological Society.

  13. Self-compensating solenoid valve

    NASA Technical Reports Server (NTRS)

    Woeller, Fritz H. (Inventor); Matsumoto, Yutaka (Inventor)

    1987-01-01

    A solenoid valve is described in which both an inlet and an outlet of the valve are sealed when the valve is closed. This double seal compensates for leakage at either the inlet or the outlet by making the other seal more effective in response to the leakage and allows the reversal of the flow direction by simply switching the inlet and outlet connections. The solenoid valve has a valve chamber within the valve body. Inlet and outlet tubes extend through a plate into the chamber. A movable core in the chamber extends into the solenoid coil. The distal end of the core has a silicone rubber plug. Other than when the solenoid is energized, the compressed spring biases the core downward so that the surface of the plug is in sealing engagement with the ends of the tubes. A leak at either end increases the pressure in the chamber, resulting in increased sealing force of the plug.

  14. Ureteric catheterization via an ileal conduit: technique and retrieval of a JJ stent.

    PubMed

    Wah, T M; Kellett, M J

    2004-11-01

    Retrograde ureteric catheterization of a patient with an ileal conduit is difficult, because guide wires and catheters coil in the conduit. A modified loopogram, using a Foley catheter as a fulcrum through which catheters can be advanced to the ureteric anastomosis, is described. This technique was used to remove a JJ stent, which had been inserted previously across a stricture in one ureter, the stent crossing from one kidney to the other.

  15. Concomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.

    PubMed

    Aydin, Unal; Gul, Mehmet; Aslan, Serkan; Akkaya, Emre; Yildirim, Aydin

    2015-04-28

    Transcatheter valve implantation is a novel interventional technique, which was developed as an  alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.

  16. Bidirectional piston valve

    DOEpatents

    Fischer, Harry C.

    1977-01-01

    This invention is a reversing valve having an inlet, an outlet, and an inlet-outlet port. The valve is designed to respond to the introduction of relatively high-pressure fluid at its inlet or, alternatively, of lower-pressure fluid at its inlet-outlet port. The valve includes an axially slidable assembly which is spring-biased to a position where it isolates the inlet and connects the inlet-outlet port to the outlet. The admission of high-pressure fluid to the inlet displaces the slidable assembly to a position where the outlet is isolated and the inlet is connected to the inlet-outlet port. The valve is designed to minimize pressure drops and leakage. It is of a reliable and comparatively simple design.

  17. Anterior urethral valve associated with posterior urethral valves.

    PubMed

    Kajbafzadeh, A M; Jangouk, P; Ahmadi Yazdi, C

    2005-12-01

    The association of anterior urethral valve (AUV) with posterior urethral valve (PUV) is rare. A 7-month-old infant was presented at a district hospital with episodes of acute pyelonephritis. He was treated medically and a voiding cystourethrogram (VCUG) confirmed bilateral vesico-urethral reflux. The presence of concomitant AUV and PUV was not recognized. He underwent several surgical procedures, which failed. He had reflux recurrence following two antireflux procedures. He had urinary retention after each operation, which was managed by vesicostomy and perineal urethrostomy. At the age of 3.5 years, he was referred to our paediatric urology clinic. Noticing the AUV and PUV in the past VCUG, the valves were fulgurated. Urodynamic study before and 3 months after valve ablation showed a high voiding pressure. VCUG 6 months following ablation showed no reflux, but several uroflowmetric studies showed a staccato and interrupted pattern. Empirical treatment with an alpha-blocker was started. One year after treatment, a repeat VCUG showed no reflux. Uroflowmetry and urodynamic studies returned to normal. The perineal urethrostomy was closed. The child was asymptomatic after 9 months of follow up.

  18. Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis.

    PubMed

    Wijesinghe, Namal; Ye, Jian; Rodés-Cabau, Josep; Cheung, Anson; Velianou, James L; Natarajan, Madhu K; Dumont, Eric; Nietlispach, Fabian; Gurvitch, Ronen; Wood, David A; Tay, Edgar; Webb, John G

    2010-11-01

    We evaluated transcatheter aortic valve implantation (TAVI) in high-risk patients with bicuspid aortic valve (BAV) stenosis. TAVI shows promise in the treatment of severe stenosis of triscupid aortic valves, especially in high-risk patients. However, BAV stenosis has been considered a contraindication to TAVI. Eleven patients (age 52 to 90 years) with symptomatic severe BAV stenosis underwent TAVI at 3 Canadian tertiary hospitals between May 2006 and April 2010. All patients were considered high risk for surgical aortic valve replacement. Edwards-SAPIEN transcatheter heart valves (Edwards Lifesciences, Inc., Irvine, California) were used. Transfemoral or transapical access was selected, depending on the adequacy of femoral access. Access was transfemoral in 7 patients and transapical in 4 patients. There were no intraprocedural complications. Significant symptomatic and hemodynamic improvement was observed in 10 of 11 patients. Baseline aortic valve area of 0.65 ± 0.17 cm(2) and mean transaortic pressure gradient of 41 ± 22.4 mm Hg were improved to 1.45 ± 0.3 cm(2) and 13.4 ± 5.7 mm Hg, respectively. Two patients had moderate perivalvular leaks. At the 30-day follow-up there were 2 deaths due to multisystem failure in 2 transapical patients. In 1 patient an undersized, suboptimally positioned, unstable valve required late conversion to open surgery. TAVI in selected high-risk patients with severe BAV stenosis can be successfully performed with acceptable clinical outcomes but will require further evaluation. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Systolic Anterior Motion of the Mitral Valve after Mitral Valve Repair

    PubMed Central

    Sternik, Leonid; Zehr, Kenton J.

    2005-01-01

    Factors predisposing patients to systolic anterior motion of the mitral valve (SAM) with left ventricular outflow tract (LVOT) obstruction after mitral valve repair are the presence of a myxomatous mitral valve with redundant leaflets, a nondilated hyperdynamic left ventricle, and a short distance between the mitral valve coaptation point and the ventricular septum after repair. From December 1999 through March 2000, we used our surgical method in 6 patients with severely myxomatous regurgitant mitral valves who were at risk of developing SAM. Leaflets were markedly redundant in all 6. Left ventricular function was hyperdynamic in 4 patients and normal in 2. Triangular or quadrangular resection of the midportion of the posterior leaflet and posterior band annuloplasty were performed. To prevent SAM and LVOT obstruction, extra, posteriorly directed, mid-posterior-leaflet secondary chordae tendineae, which would otherwise have been resected, were transferred to the underside of the middle of the mid-anterior leaflet with a small piece of associated valve as an anchoring pledget. This kept the redundant anterior leaflet edge, which extended below the coaptation point, away from the LVOT. No post-repair SAM or LVOT obstruction was observed on intraoperative or discharge echocardiography. All patients had no or trivial residual mitral regurgitation. We conclude that extra chordae tendineae, when available, can be used in mitral valve repair to tether the redundant anterior leaflet and thus prevent it from flipping into the LVOT. This will theoretically prevent SAM and LVOT obstruction in patients with risk factors for SAM. PMID:15902821

  20. Fast closing valve

    DOEpatents

    Hanson, Clark L.

    1984-01-10

    A valve is provided for protecting the high vacuum of a particle accelera in the event of air leakage, wherein the valve provides an axially symmetrical passage to avoid disturbance of the partical beam during normal operation, and yet enables very rapid and tight closure of the beam-carrying pipe in the event of air leakage. The valve includes a ball member (30) which can rotate between a first position wherein a bore (32) in the member is aligned with the beam pipe, and a second position out of line with the pipe. A seal member (38) is flexibly sealed to the pipe, and has a seal end which can move tightly against the ball member after the bore has rotated out of line with the pipe, to thereby assure that the seal member does not retard rapid rotation of the ball valve member. The ball valve member can be rapidly rotated by a conductive arm (40) fixed to it and which is rotated by the discharge of a capacitor bank through coils (44, 45) located adjacent to the arm.

  1. Downhole surge valve for earth boring apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, D.W.

    1990-05-29

    This patent describes a boring tool assembly having an underground percussion mole boring tool powered by a working fluid, the tool being driven through the earth by a rigid drill string pushed by a drilling frame, and a downhole valve assembly fixed between the downhole end of the drill string and the too, the improved downhole valve assembly. It comprises: a valve spool having an open first end, a closed second end and a peripheral sidewall, an axial bore extending partly through the valve spool from the open first end; a radial passage adjacent the closed second and of themore » valve spool, the radial passage extending radially from the valve spool axial bore through the valve spool peripheral sidewall; an axial groove in the peripheral sidewall of the valve spool; a valve body having a first end, a second end and a peripheral sidewall, an axial bore extending through the valve body, the valve spool extending through the valve body axial bore so that the second end of the valve body is adjacent the closed second end of the valve spool, the valve spool being axially moveable within the valve body axial bore; an axial slot; a free-floating key element; a valve housing; and seal means.« less

  2. Combined use of decellularized allogeneic artery conduits with autologous transdifferentiated adipose-derived stem cells for facial nerve regeneration in rats.

    PubMed

    Sun, Fei; Zhou, Ke; Mi, Wen-juan; Qiu, Jian-hua

    2011-11-01

    Natural biological conduits containing seed cells have been widely used as an alternative strategy for nerve gap reconstruction to replace traditional nerve autograft techniques. The purpose of this study was to investigate the effects of a decellularized allogeneic artery conduit containing autologous transdifferentiated adipose-derived stem cells (dADSCs) on an 8-mm facial nerve branch lesion in a rat model. After 8 weeks, functional evaluation of vibrissae movements and electrophysiological assessment, retrograde labeling of facial motoneurons and morphological analysis of regenerated nerves were performed to assess nerve regeneration. The transected nerves reconstructed with dADSC-seeded artery conduits achieved satisfying regenerative outcomes associated with morphological and functional improvements which approached those achieved with Schwann cell (SC)-seeded artery conduits, and superior to those achieved with artery conduits alone or ADSC-seeded artery conduits, but inferior to those achieved with nerve autografts. Besides, numerous transplanted PKH26-labeled dADSCs maintained their acquired SC-phenotype and myelin sheath-forming capacity inside decellularized artery conduits and were involved in the process of axonal regeneration and remyelination. Collectively, our combined use of decellularized allogeneic artery conduits with autologous dADSCs certainly showed beneficial effects on nerve regeneration and functional restoration, and thus represents an alternative approach for the reconstruction of peripheral facial nerve defects. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Update of transcatheter valve treatment

    PubMed Central

    Liu, Xian-bao; Wang, Jian-an

    2013-01-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair—MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed. PMID:23897785

  4. Pressure control valve. [inflating flexible bladders

    NASA Technical Reports Server (NTRS)

    Lambson, K. H. (Inventor)

    1980-01-01

    A control valve is provided which is adapted to be connected between a pressure source, such as a vacuum pump, and a pressure vessel so as to control the pressure in the vessel. The valve comprises a housing having a longitudinal bore which is connected between the pump and vessel, and a transversely movable valve body which controls the air flow through an air inlet in the housing. The valve body includes cylindrical and conical shaped portions which cooperate with reciprocally shaped portions of the housing to provide flow control. A filter in the air inlet removes foreign matter from the air. The bottom end of the valve body is screwed into the valve housing control knob formed integrally with the valve body and controls translation of the valve body, and the opening and closing of the valve.

  5. 38. Launch Area, Underground Missile Storage Structure, detail of conduit ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. Launch Area, Underground Missile Storage Structure, detail of conduit service junction - NIKE Missile Battery PR-79, Launch Area, East Windsor Road south of State Route 101, Foster, Providence County, RI

  6. "Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve).

    PubMed

    Vavouranakis, Manolis; Vrachatis, Dimitrios A; Toutouzas, Konstantinos P; Chrysohoou, Christina; Stefanadis, Christodoulos

    2010-11-05

    Two techniques for correcting malpositioning occurring during percutaneous aortic valve replacement (PAVR) with the CoreValve ReValving™ System are described in this article. The "Removing and Reinserting Technique" was used in 2 patients, in whom the prosthesis was positioned too high. The "Snare Technique" was used in 1 patient, in whom the prosthesis was implanted too low. In all patients the aortic valve prosthesis was successfully re-implanted. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Passively actuated valve

    DOEpatents

    Modro, S. Michael; Ougouag, Abderrafi M.

    2005-09-20

    A passively actuated valve for isolating a high pressure zone from a low pressure zone and discontinuing the isolation when the pressure in the high pressure zone drops below a preset threshold. If the pressure in the high pressure zone drops below the preset threshold, the valve opens and allows flow from the high pressure zone to the low pressure zone. The valve remains open allowing pressure equalization and back-flow should a pressure inversion between the two pressure zone occur.

  8. Mitral Valve Prolapse

    MedlinePlus

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  9. Heart valve surgery

    MedlinePlus

    ... with an artificial valve (this is called the Ross Procedure). This procedure may be useful for people ... valve that does not close all the way will allow blood to leak backwards. This is called ...

  10. Intraluminal valves: development, function and disease

    PubMed Central

    Geng, Xin; Cha, Boksik; Mahamud, Md. Riaj

    2017-01-01

    ABSTRACT The circulatory system consists of the heart, blood vessels and lymphatic vessels, which function in parallel to provide nutrients and remove waste from the body. Vascular function depends on valves, which regulate unidirectional fluid flow against gravitational and pressure gradients. Severe valve disorders can cause mortality and some are associated with severe morbidity. Although cardiac valve defects can be treated by valve replacement surgery, no treatment is currently available for valve disorders of the veins and lymphatics. Thus, a better understanding of valves, their development and the progression of valve disease is warranted. In the past decade, molecules that are important for vascular function in humans have been identified, with mouse studies also providing new insights into valve formation and function. Intriguing similarities have recently emerged between the different types of valves concerning their molecular identity, architecture and development. Shear stress generated by fluid flow has also been shown to regulate endothelial cell identity in valves. Here, we review our current understanding of valve development with an emphasis on its mechanobiology and significance to human health, and highlight unanswered questions and translational opportunities. PMID:29125824

  11. Variable Valve Actuation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    Many approaches exist to enable advanced mode, low temperature combustion systems for diesel engines - such as premixed charge compression ignition (PCCI), Homogeneous Charge Compression Ignition (HCCI) or other HCCI-like combustion modes. The fuel properties and the quantity, distribution and temperature profile of air, fuel and residual fraction in the cylinder can have a marked effect on the heat release rate and combustion phasing. Figure 1 shows that a systems approach is required for HCCI-like combustion. While the exact requirements remain unclear (and will vary depending on fuel, engine size and application), some form of substantially variable valve actuation ismore » a likely element in such a system. Variable valve actuation, for both intake and exhaust valve events, is a potent tool for controlling the parameters that are critical to HCCI-like combustion and expanding its operational range. Additionally, VVA can be used to optimize the combustion process as well as exhaust temperatures and impact the after treatment system requirements and its associated cost. Delphi Corporation has major manufacturing and product development and applied R&D expertise in the valve train area. Historical R&D experience includes the development of fully variable electro-hydraulic valve train on research engines as well as several generations of mechanical VVA for gasoline systems. This experience has enabled us to evaluate various implementations and determine the strengths and weaknesses of each. While a fully variable electro-hydraulic valve train system might be the 'ideal' solution technically for maximum flexibility in the timing and control of the valve events, its complexity, associated costs, and high power consumption make its implementation on low cost high volume applications unlikely. Conversely, a simple mechanical system might be a low cost solution but not deliver the flexibility required for HCCI operation. After modeling more than 200 variations of the

  12. Space Vehicle Valve System

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  13. ULTRA HIGH VACUUM VALVE

    DOEpatents

    Fry, W.A.

    1962-05-29

    A valve for high vacuum applications such as the CStellarator where chamber pressures as low as 2 x 10/sup -10/ mm Hg are necessary is designed with a line-of-sight path through the valve for visual inspection of the contents of reactants in such chambers. The valve comprises a turnable resilient metal ball having an aperture therethrough, means for selectively turning the ball to rotate the axis of its line-of-sight path, and soft, deformable opposing orifices that are movable relatively toward said ball to seal with opposite ball surfaces upon said movement of said axis of said line-of-sight path. The valve also includes a bellows seal connected between said orifices and internal actuating means that eliminates the requirement for gasketed turnable valve closing stems. (AEC)

  14. All metal valve structure for gas systems

    DOEpatents

    Baker, Ray W.; Pawlak, Donald A.; Ramey, Alford J.

    1984-11-13

    A valve assembly with a resilient metal seat member is disclosed for providing a gas-tight seal in a gas handling system. The valve assembly also includes a valve element for sealing against the valve seat member; and an actuating means for operating the valve element. The valve seat member is a one-piece stainless steel ring having a central valve port and peripheral mounting flange, and an annular corrugation in between. A groove between the first and second ridges serves as a flexure zone during operation of the valve member and thus provides the seating pressure between the inner ridge or valve seat and the valve element. The outer annular ridge has a diameter less than said valve element to limit the seating motion of the valve element, preventing non-elastic deformation of the seat member.

  15. All-metal valve structure for gas systems

    DOEpatents

    Baker, R.W.; Pawlak, D.A.; Ramey, A.J.

    1982-06-10

    A valve assembly with a resilient metal seat member is disclosed for providing a gas-tight seal in a gas handling system. The valve assembly also includes a valve element for sealing against the valve seat member; and an actuating means for operating the valve element. The valve seat member is a one-piece stainless steel ring having a central valve port and peripheral mounting flange, and an annular corrugation in between. A groove between the first and second ridges serves as a flexure zone during operation of the valve member and thus provides the seating pressure between the inner ridge or valve seat and the valve element. The outer annular ridge has a diameter less than said valve element to limit the seating motion of the valve element, preventing non-elastic deformation of the seat member.

  16. Left atrium function by 2D speckle tracking in aortic valve disease.

    PubMed

    Salas-Pacheco, Jose L; Ávila-Vanzzini, Nydia; Eugenia, Ruiz-Esparza M; Arias-Godínez, Jose A

    2016-12-01

    A paucity of data exists about left atrium (LA) function in aortic valve stenosis (AS) or regurgitation (AR). Two-dimensional speckle tracking echocardiography allows the noninvasive study of LA functional disturbances in aortic valve disease and their impact in the development of pulmonary hypertension (PH). Consecutive patients with moderate or severe AS or AR were included. Left ventricle (LV) and LA speckle tracking strain quantification was performed. We included 42 patients with AS and 30 with AR. Differences were not found in LA volumes and strain in AS or AR. The LA volumetric derangements parallel the decrease in LA longitudinal strain. Maximum LA volume, minimum LA volume, and indexed LA volume were higher in severe valvular disease (SVD) than in moderate [23 cc (P=.018, IC 95% : 4-41), 16 cc (P=.035, IC 95% : 2-31), and 14 cc (P=.022, IC 95% : 2-25), respectively], occurred in the same way with LA strain in the conduit (6.3%, P=.034, IC 95% : 1-12) and reservoir (7.1%, P=.04, IC 95% : 2-14) phases. In multivariable model, strain of reservoir phase was the variable mainly associated with PH; each decrease in one unit of strain of reservoir phase increased 6% the PH probability (OR: 1.06, P=.01). This study demonstrates that in patients with AS and AR, the LA has a similar behavior and that exist a close correlation between LA volumetric and functional parameters. The variable mainly associated with PH was LA strain of reservoir phase. © 2016, Wiley Periodicals, Inc.

  17. Microblower assisted barometric valve

    DOEpatents

    Rossabi, Joseph; Hyde, Warren K.; Riha, Brian D.; Jackson, Dennis G.; Sappington, Frank

    2005-12-06

    A gas exchange apparatus is provided which provides for both passive fluid flow and blower associated fluid flow through a barometric valve. A battery powered blower is provided which allows for operation of the barometric valve during times when the barometric valve would otherwise be closed, and provides for enhanced volume of gas exchange.

  18. Liquid rocket valve assemblies

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design and operating characteristics of valve assemblies used in liquid propellant rocket engines are discussed. The subjects considered are as follows: (1) valve selection parameters, (2) major design aspects, (3) design integration of valve subassemblies, and (4) assembly of components and functional tests. Information is provided on engine, stage, and spacecraft checkout procedures.

  19. Structure of a bacterial cell surface decaheme electron conduit

    USDA-ARS?s Scientific Manuscript database

    Some bacterial species are able to utilize extracellular mineral forms of iron and manganese as respiratory electron acceptors. In Shewanella oneidensis this involves decaheme cytochromes that are located on the bacterial cell surface at the termini of trans-outer-membrane electron transfer conduits...

  20. Development and Implementation of a Segment/Junction Box Level Database for the ITS Fiber Optic Conduit Network

    DOT National Transportation Integrated Search

    2012-03-01

    This project initiated the development of a computerized database of ITS facilities, including conduits, junction : boxes, cameras, connections, etc. The current system consists of a database of conduit sections of various lengths. : Over the length ...

  1. Natural killer T cell facilitated engraftment of rat skin but not islet xenografts in mice.

    PubMed

    Gordon, Ethel J; Kelkar, Vinaya

    2009-01-01

    We have studied cellular components required for xenograft survival mediated by anti-CD154 monoclonal antibody (mAb) and a transfusion of donor spleen cells and found that the elimination of CD4(+) but not CD8(+) cells significantly improves graft survival. A contribution of other cellular components, such as natural killer (NK) cells and natural killer T (NKT) cells, for costimulation blockade-induced xenograft survival has not been clearly defined. We therefore tested the hypothesis that NK or NKT cells would promote rat islet and skin xenograft acceptance in mice. Lewis rat islets or skin was transplanted into wild type B6 mice or into B6 mice that were Jalpha18(null), CD1(null), or beta2 microglobulin (beta2M)(null) NK 1.1 depleted, or perforin(null). Graft recipients were pretreated with an infusion of donor derived spleen cells and a brief course of anti-CD154 mAb treatments. Additional groups received mAb or cells only. We first observed that the depletion of NK1.1 cells does not significantly interfere with graft survival in C57BL/6 (B6) mice. We used NKT cell deficient B6 mice to test the hypothesis that NKT cells are involved in islet and skin xenograft survival in our model. These mice bear a null mutation in the gene for the Jalpha18 component of the T-cell receptor. The component is uniquely associated with NKT cells. We found no difference in islet xenograft survival between Jalpha18(null) and wild type B6 mice. In contrast, median skin graft survival appeared shorter in Jalpha18(null) recipients. These data imply a role for Jalpha18(+) NKT cells in skin xenograft survival in treated mice. In order to confirm this inference, we tested skin xenograft survival in B6 CD1(null) mice because NKT cells are CD1 restricted. Results of these trials demonstrate that the absence of CD1(+) cells adversely affects rat skin graft survival. An additional assay in beta2M(null) mice demonstrated a requirement for major histocompatibility complex (MHC) class I

  2. [Effects of baicalin on HL-60 cell xenografts in nude mice and its mechanism].

    PubMed

    Zheng, Jing; Hu, Jian-Da; Huang, Yi; Chen, Ying-Yu; Li, Jing; Chen, Bu-Yuan

    2012-10-01

    This study was aimed to investigate the effects of baicalin on HL-60 cell xenografts in nude mice in vivo and explore its mechanism. Xenograft tumor model of HL-60 cells in nude mice was established, which was divided randomly into 6 groups: negative control group (injection of 5% NaHCO(3)), 25, 50 and 100 mg/kg baicalin groups, combination group (50 mg/kg baicalin + 2 mg/kg VP16) and positive control group (VP16 4 mg/kg). The nude mice with HL-60 cell xenografts were treated with drugs via intraperitoneal injection daily. After treatment for 14 days average weigh and inhibitory rate of transplanted tumor stripped from 5 nude mice in each group were calculated, and the ultrastructure change of xenografts cells were tested by transmission electron microscopy. Histopathologic examination was used to observed the change of main organs in nude mice. The expression of signaling molecular PI3K/Akt proteins extracted from xenografts was detected by Western blot. The effects of baicalin on overall survival time in nude mice with HL-60 cell xenografts were evaluated. The results showed that baicalin could inhibit the growth of transplanted tumors in dose-dependent manner. There were more necrotic and apoptotic cells in mice of baicalin-treated groups and combination group than that in mice of negative control group. Baicalin could inhibit the proliferation of HL-60 cells in vivo by down-regulating the PI3K/Akt/mTOR signal pathway, where the expressions of p-Akt, mTOR and p-mTOR proteins decreased compared with negative control group, and no significant difference of Akt expression was found between different groups. Compared with negative control group, the median survival time of mice in combination group was more prolongated (P < 0.05). It is concluded that baicalin can inhibit growth and induce apoptosis of HL-60 cell xenografts in nude mice, and prolong median survival time of nude mice. The possible mechanisms may be related to inhibition of Akt activity and down

  3. Aerosol penetration through respirator exhalation valves.

    PubMed

    Bellin, P; Hinds, W C

    1990-10-01

    Exhalation valves are a critical component of industrial respirators. They are designed to permit minimal inward leakage of air contaminants during inhalation and provide low resistance during exhalation. Under normal conditions, penetration of aerosol through exhalation valves is minimal. The exhalation valve is, however, a vulnerable component of a respirator and under actual working conditions may become dirty or damaged to the point of causing significant leakage. Aerosol penetration was measured for normal exhalation valves and valves compromised by paint or fine copper wires on the valve seat. Penetration increased with increasing wire diameter. A wire 250 microns in diameter allowed greater than 1% penetration into the mask cavity. Dirt or paint accumulated on the exhalation valve allowed a similar level of penetration. Work rate had little effect on observed penetration. Penetration decreased significantly with increasing aerosol particle size. The amount of material on the valve or valve seat necessary for significant (greater than 0.5%) inward leakage in a half-mask respirator could be readily observed by careful inspection of the exhalation valve and its seat in good lighting conditions.

  4. Spool-Valve Pressure-Difference Regulator

    NASA Technical Reports Server (NTRS)

    Grasso, A. P.

    1983-01-01

    Valves maintain preset pressure difference between gas flows. Two spool valves connected by shaft move back and forth in response to changes in pressure in oxygen and hydrogen chambers. Spool-valve assembly acts to restore pressures to preset difference. By eliminating diaphragms, pressure exerted directly on external end of spool valve; however, forces and therefore sensitivity of assembly are reduced.

  5. Valve-in-valve using an Edwards Sapien XT into a JenaValve in a patient with a low originating left coronary artery and a heavily calcified aorta.

    PubMed

    Fujita, Buntaro; Scholtz, Smita; Ensminger, Stephan

    2016-04-01

    Coronary obstruction during transcatheter aortic valve implantation is a potentially life-threatening complication. Most of the widely used transcatheter heart valves require a certain distance between the basal aortic annular plane and the origins of the coronary arteries. We report the case of a successful valve-in-valve procedure with an Edwards SAPIEN XT valve into a JenaValve as a bail-out procedure in a patient with a low originating left coronary artery and a heavily calcified aorta. © 2015 Wiley Periodicals, Inc.

  6. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    PubMed

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  7. Parastomal hernias after radical cystectomy and ileal conduit diversion

    PubMed Central

    Donahue, Timothy F.

    2016-01-01

    Parastomal hernia, defined as an "incisional hernia related to an abdominal wall stoma", is a frequent complication after conduit urinary diversion that can negatively impact quality of life and present a clinically significant problem for many patients. Parastomal hernia (PH) rates may be as high as 65% and while many patients are asymptomatic, in some series up to 30% of patients require surgical intervention due to pain, leakage, ostomy appliance problems, urinary obstruction, and rarely bowel obstruction or strangulation. Local tissue repair, stoma relocation, and mesh repairs have been performed to correct PH, however, long-term results have been disappointing with recurrence rates of 30%–76% reported after these techniques. Due to high recurrence rates and the potential morbidity of PH repair, efforts have been made to prevent PH development at the time of the initial surgery. Randomized trials of circumstomal prophylactic mesh placement at the time of colostomy and ileostomy stoma formation have shown significant reductions in PH rates with acceptably low complication profiles. We have placed prophylactic mesh at the time of ileal conduit creation in patients at high risk for PH development and found it to be safe and effective in reducing the PH rates over the short-term. In this review, we describe the clinical and radiographic definitions of PH, the clinical impact and risk factors associated with its development, and the use of prophylactic mesh placement for patients undergoing ileal conduit urinary diversion with the intent of reducing PH rates. PMID:27437533

  8. Melanoma patient derived xenografts acquire distinct Vemurafenib resistance mechanisms

    PubMed Central

    Monsma, David J; Cherba, David M; Eugster, Emily E; Dylewski, Dawna L; Davidson, Paula T; Peterson, Chelsea A; Borgman, Andrew S; Winn, Mary E; Dykema, Karl J; Webb, Craig P; MacKeigan, Jeffrey P; Duesbery, Nicholas S; Nickoloff, Brian J; Monks, Noel R

    2015-01-01

    Variable clinical responses, tumor heterogeneity, and drug resistance reduce long-term survival outcomes for metastatic melanoma patients. To guide and accelerate drug development, we characterized tumor responses for five melanoma patient derived xenograft models treated with Vemurafenib. Three BRAFV600E models showed acquired drug resistance, one BRAFV600E model had a complete and durable response, and a BRAFV600V model was expectedly unresponsive. In progressing tumors, a variety of resistance mechanisms to BRAF inhibition were uncovered, including mutant BRAF alternative splicing, NRAS mutation, COT (MAP3K8) overexpression, and increased mutant BRAF gene amplification and copy number. The resistance mechanisms among the patient derived xenograft models were similar to the resistance pathways identified in clinical specimens from patients progressing on BRAF inhibitor therapy. In addition, there was both inter- and intra-patient heterogeneity in resistance mechanisms, accompanied by heterogeneous pERK expression immunostaining profiles. MEK monotherapy of Vemurafenib-resistant tumors caused toxicity and acquired drug resistance. However, tumors were eradicated when Vemurafenib was combined the MEK inhibitor. The diversity of drug responses among the xenograft models; the distinct mechanisms of resistance; and the ability to overcome resistance by the addition of a MEK inhibitor provide a scheduling rationale for clinical trials of next-generation drug combinations. PMID:26101714

  9. Bioprinting a cardiac valve.

    PubMed

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    PubMed Central

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  11. Fluid dynamic characterization of a polymeric heart valve prototype (Poli-Valve) tested under continuous and pulsatile flow conditions.

    PubMed

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D; Costantino, Maria Laura

    2015-11-01

    Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.

  12. The sensitivity of conduit flow models to basic input parameters: there is no need for magma trolls!

    NASA Astrophysics Data System (ADS)

    Thomas, M. E.; Neuberg, J. W.

    2012-04-01

    Many conduit flow models now exist and some of these models are becoming extremely complicated, conducted in three dimensions and incorporating the physics of compressible three phase fluids (magmas), intricate conduit geometries and fragmentation processes, to name but a few examples. These highly specialised models are being used to explain observations of the natural system, and there is a danger that possible explanations may be getting needlessly complex. It is coherent, for instance, to propose the involvement of sub-surface dwelling magma trolls as an explanation for the change in a volcanoes eruptive style, but assuming the simplest explanation would prevent such additions, unless they were absolutely necessary. While the understanding of individual, often small scale conduit processes is increasing rapidly, is this level of detail necessary? How sensitive are these models to small changes in the most basic of governing parameters? Can these changes be used to explain observed behaviour? Here we will examine the sensitivity of conduit flow models to changes in the melt viscosity, one of the fundamental inputs to any such model. However, even addressing this elementary issue is not straight forward. There are several viscosity models in existence, how do they differ? Can models that use different viscosity models be realistically compared? Each of these viscosity models is also heavily dependent on the magma composition and/or temperature, and how well are these variables constrained? Magma temperatures and water contents are often assumed as "ball-park" figures, and are very rarely exactly known for the periods of observation the models are attempting to explain, yet they exhibit a strong controlling factor on the melt viscosity. The role of both these variables will be discussed. For example, using one of the available viscosity models a 20 K decrease in temperature of the melt results in a greater than 100% increase in the melt viscosity. With changes of

  13. 79. COVERED CONDUIT ACROSS ANTELOPE VALLEY WITH WIND FARM IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    79. COVERED CONDUIT ACROSS ANTELOPE VALLEY WITH WIND FARM IN DISTANCE - Los Angeles Aqueduct, From Lee Vining Intake (Mammoth Lakes) to Van Norman Reservoir Complex (San Fernando Valley), Los Angeles, Los Angeles County, CA

  14. Low energy high pressure miniature screw valve

    DOEpatents

    Fischer, Gary J [Sandia Park, NM; Spletzer, Barry L [Albuquerque, NM

    2006-12-12

    A low energy high pressure screw valve having a valve body having an upper portion and a lower portion, said lower portion of said valve body defining an inlet flow passage and an outlet flow passage traversing said valve body to a valve seat, said upper portion of said valve body defining a cavity at said valve seat, a diaphragm restricting flow between said upper portion of said valve body and said lower portion, said diaphragm capable of engaging said valve seat to restrict fluid communication between said inlet passage and said outlet passage, a plunger within said cavity supporting said diaphragm, said plunger being capable of engaging said diaphragm with said valve seat at said inlet and outlet fluid passages, said plunger being in point contact with a drive screw having threads engaged with opposing threads within said upper portion of said valve body such engagement allowing motion of said drive screw within said valve body.

  15. Mitral valve surgery - minimally invasive

    MedlinePlus

    ... flow. Your valve has developed an infection (infectious endocarditis). You have severe mitral valve prolapse that is ... function. Damage to your heart valve from infection (endocarditis). A minimally invasive procedure has many benefits. There ...

  16. 49 CFR 195.116 - Valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PIPELINE Design Requirements § 195.116 Valves. Each valve installed in a pipeline system must comply with the following: (a) The valve must be of a sound engineering design. (b) Materials subject to the...

  17. Patient-specific orthotopic glioblastoma xenograft models recapitulate the histopathology and biology of human glioblastomas in situ.

    PubMed

    Joo, Kyeung Min; Kim, Jinkuk; Jin, Juyoun; Kim, Misuk; Seol, Ho Jun; Muradov, Johongir; Yang, Heekyoung; Choi, Yoon-La; Park, Woong-Yang; Kong, Doo-Sik; Lee, Jung-Il; Ko, Young-Hyeh; Woo, Hyun Goo; Lee, Jeongwu; Kim, Sunghoon; Nam, Do-Hyun

    2013-01-31

    Frequent discrepancies between preclinical and clinical results of anticancer agents demand a reliable translational platform that can precisely recapitulate the biology of human cancers. Another critical unmet need is the ability to predict therapeutic responses for individual patients. Toward this goal, we have established a library of orthotopic glioblastoma (GBM) xenograft models using surgical samples of GBM patients. These patient-specific GBM xenograft tumors recapitulate histopathological properties and maintain genomic characteristics of parental GBMs in situ. Furthermore, in vivo irradiation, chemotherapy, and targeted therapy of these xenograft tumors mimic the treatment response of parental GBMs. We also found that establishment of orthotopic xenograft models portends poor prognosis of GBM patients and identified the gene signatures and pathways signatures associated with the clinical aggressiveness of GBMs. Together, the patient-specific orthotopic GBM xenograft library represent the preclinically and clinically valuable "patient tumor's phenocopy" that represents molecular and functional heterogeneity of GBMs. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  18. AC losses and stability on large cable-in-conduit superconductors

    NASA Astrophysics Data System (ADS)

    Bruzzone, Pierluigi

    1998-12-01

    The cable-in-conduit superconductors are preferred for applications where the AC losses and stability are a major concern, e.g., fusion magnets and SMES. A review of coupling currents loss results for both NbTi and Nb 3Sn cable-in-conduit conductors (CICC) is presented and the AC loss relevant features are listed, with special emphasis for the role of the interstrand resistance and strand coating. The transient stability approach for CICCs is discussed and the analytical models are quoted as well as the relevant experimental database. The likely spectrum of transient disturbance in CICC is reviewed and the need to account for interstrand current sharing in the design is outlined. Eventually a practical criterion for the interstrand resistance is proposed to link the stability and AC loss design.

  19. Design and production of stopper made of concrete foam composite used for open channel conduit cover and parking bumper

    NASA Astrophysics Data System (ADS)

    Syam, Bustami; Sebayang, Alexander; Sebayang, Septian; Muttaqin, Maraghi; Darmadi, Harry; Basuki, WS; Sabri, M.; Abda, S.

    2018-03-01

    Open channel conduit is designed and produced with the aims to reduce excess water, whether from rain, seepage, or excess irrigation water in an area. It is also included in one of the important components of urban infrastructure in tackling the problem of flooding and waterlogging. On the roadway, e.g. housing complex the open channel conduits should function the same, however conduit covers are needed. The covers should be also designed to function as parking bumper. This paper discusses the design and production of the stoppers using our newly invented materials; the stoppers are structurally tested under static, dynamic, and bump test. Response of the conduit cover are found from structural analysis using finite element software ANSYS MECHANICAL version 17.5. Two types of stoppers are introduced: flat and curvy configuration. It was obtained that both types are suitable for open channel conduit cover and parking bumper.

  20. Solenoid valve performance characteristics studied

    NASA Technical Reports Server (NTRS)

    Abe, J. T.; Blackburn, S.

    1970-01-01

    Current and voltage waveforms of a solenoid coil are recorded as the valve opens and closes. Analysis of the waveforms with respect to time and the phase of the valve cycle accurately describes valve performance.

  1. Effect of combined locally delivered growth factors and systemic sildenafil citrate on microrecanalization in biodegradable conduit for vas deferens reconstruction.

    PubMed

    Rosevear, Henry M; Krishnamachari, Yogita; Ariza, Carlos A; Mallapragada, Surya K; Salem, Aliasger K; Griffith, Thomas S; De Young, Barry R; Wald, Moshe

    2012-04-01

    To investigate the effect of the combination of locally delivered growth factors and oral sildenafil citrate on cross-conduit microrecanalization. A total of 42 rats were divided into 7 groups. Of the 42 rats, 6 underwent bilateral vasectomy and bilateral end-to-end vasovasostomy and 12 underwent bilateral vasectomy. Of the latter 12, 6 received sildenafil citrate orally (10 mg/kg/d) for 24 weeks and 6 received placebo. A total of 24 rats underwent bilateral vasectomy and bilateral reconstruction with implantation of a 5-mm biodegradable conduit that bridged the 2 vasal ends. Of the 24 rats with conduits, 12 also had 250 pg of transforming growth factor-β and 12.5 pg of platelet-derived growth factor-β sustained release nanoparticles placed in immediate proximity to the conduit. The remaining 12 rats with conduits (6 without growth factors and 6 with growth factors) also received sildenafil citrate orally (10 mg/kg/d) for 24 weeks; the others received placebo. The reconstructed segments were harvested for histologic examination at 24 weeks. Five of 6 primary vasovasostomy and no vasectomy-only rats sired litters. Significantly more microcanals per conduit were observed in rats receiving sildenafil citrate: without growth factors, 3.9 vs. 0 canals/conduit (P < 0.001); with growth factors, 5.5 vs. 0.25 canals/conduit (P < 0.001). The rats receiving sildenafil citrate with growth factors showed a trend toward more microcanals per conduit than the rats receiving sildenafil citrate without growth factors (5.5 vs 3.9; P = .10). Rats receiving growth factors but no sildenafil citrate did not produce more canals than the rats receiving neither growth factor nor sildenafil citrate (0.25 vs 0; P = NS). Orally administered sildenafil citrate enhances formation of microcanalization after postvasectomy reconstruction using a biodegradable conduit in a rat model. Locally delivered growth factors appear to increase the number of microcanals. Copyright © 2012 Elsevier Inc. All

  2. 100. INTERIOR OF SKID 9A: VENT VALVE AND RELIEF VALVE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    100. INTERIOR OF SKID 9A: VENT VALVE AND RELIEF VALVE FOR RAPID-LOAD LIQUID OXYGEN TANK - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. Thermostatic Valves Containing Silicone-Oil Actuators

    NASA Technical Reports Server (NTRS)

    Bhandari, Pradeep; Birur, Gajanana C.; Bame, David P.; Karlmann, Paul B.; Prina, Mauro; Young, William; Fisher, Richard

    2009-01-01

    Flow-splitting and flow-mixing thermally actuated spool valves have been developed for controlling flows of a heat-transfer fluid in a temperature-regulation system aboard the Mars Science Laboratory (MSL) rover. Valves like these could also be useful in terrestrial temperature-regulation systems, including automobile air-conditioning systems and general refrigeration systems. These valves are required to provide smoother actuation over a wider temperature range than the flow-splitting, thermally actuated spool valves used in the Mars Explorer Rover (MER). Also, whereas the MER valves are unstable (tending to oscillate) in certain transition temperature ranges, these valves are required not to oscillate. The MER valves are actuated by thermal expansion of a wax against spring-loaded piston rods (as in common automotive thermostats). The MSL valves contain similar actuators that utilize thermal expansion of a silicone oil, because silicone-oil actuators were found to afford greater and more nearly linear displacements, needed for smoother actuation, over the required wider temperature range. The MSL valves also feature improved spool designs that reflect greater understanding of fluid dynamics, consideration of pressure drops in valves, and a requirement for balancing of pressures in different flow branches.

  4. 78 FR 69847 - North Side Canal Company; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-21

    ...--Criteria for Qualifying Conduit Hydropower Facility Satisfies (Y/ Statutory provision Description N) FPA 30(a)(3)(A), as amended by The conduit the Y HREA. facility uses is a tunnel, canal, pipeline, aqueduct... agricultural, municipal, or industrial consumption and not primarily for the generation of electricity. FPA 30...

  5. 78 FR 61985 - City of Astoria, Oregon; Notice of Preliminary Determination of a Qualifying Conduit Hydropower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-09

    ...), as amended by HREA.... The facility is constructed, operated, or maintained Y for the generation of... Conduit Hydropower Facility Satisfies Statutory provision Description (Y/N) FPA 30(a)(3)(A), as amended by HREA....... The conduit the facility uses is a tunnel, canal, Y pipeline, aqueduct, flume, ditch, or...

  6. [Status of aortic valve reconstruction and Ross operation in aortic valve diseases].

    PubMed

    Sievers, Hans H

    2002-08-01

    At first glance the aortic valve is a relative simple valve mechanism connecting the left ventricle and the ascending aorta. Detailed analysis of the different components of the aortic valve including the leaflets and sinuses revealed a complex motion of each part leading to a perfect durable valve mechanism at rest and during exercise. Theoretically, the reconstruction or imitation of these structures in patients with aortic valve disease should lead to optimal results. Prerequisite is the exact knowledge of the important functional characteristics of the aortic valve. The dynamic behavior of the aortic root closely harmonizing with the leaflets not only warrants stress minimizing and valve durability, but also optimizes coronary flow, left ventricular function and aortic impedance. The newly discovered contractile capacity of the leaflets and the root components are important for tuning the dynamics. Isolated reconstruction of the aortic valve such as decalcification, commissurotomy, plication of ring or leaflets of a tricuspid aortic valve and cusp extension are seldom indicated in contrast to the reconstruction of the bicuspid insufficient valve. Proper indication and skilled techniques lead to excellent hemodynamic and clinical intermediate-term result up to 7 years after reconstruction. Latest follow-up revealed a mean aortic insufficiency of 0.7, maximal pressure gradient of 11.4 +/- 8.5 mm Hg with zero hospital or late mortality, reoperation or thromboembolic events in 22 patients. The reconstructive techniques for aortic root aneurysm and/or type A dissection according to David or Yacoub have become routine procedures in the last 10 years. The hemodynamic and clinical results are excellent with low reoperation rate and very low risk of thromboembolism. Generally, a maximal diameter of the root of 5 cm is indicative for performing the operation. In patients with Marfan's syndrome the reconstruction should be advanced even with smaller diameters especially

  7. 98. (Credit BLV) Detail of gravity, flow conduit intake at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    98. (Credit BLV) Detail of gravity, flow conduit intake at cross Lake dam Cribbing supports extra suction intake installed in 1930. - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA

  8. Options for Heart Valve Replacement

    MedlinePlus

    ... which may include human or animal donor tissue) Ross Procedure — “Borrowing” your healthy valve and moving it ... Considerations for Surgery Medications Valve Repair Valve Replacement - Ross Procedure - Newer Surgery Options - What is TAVR? - Types ...

  9. Damage-Free Relief-Valve Disassembly

    NASA Technical Reports Server (NTRS)

    Haselmaier, H.

    1986-01-01

    Tool safely disassembles relief valves without damage to sensitive parts. Relief-valve disassembly tool used to extract valve nozzle from its housing. Holding device on tool grops nozzle. When user strikes hammer against impact disk, holding device pulls nozzle from press fit. Previously, nozzle dislodged by striking spindle above it, but practice often damaged retaining screw. New tool removes nozzle directly. With minor modifications, tool adapted to valves from different manufacturers.

  10. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    PubMed

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  11. Impact of the Learning Curve for Endoscopic Vein Harvest on Conduit Quality and Early Graft Patency

    PubMed Central

    Desai, Pranjal; Kiani, Soroosh; Thiruvanthan, Nannan; Henkin, Stanislav; Kurian, Dinesh; Ziu, Pluen; Brown, Alex; Patel, Nisarg; Poston, Robert

    2014-01-01

    Background Recent studies have suggested that endoscopic vein harvest (EVH) compromises graft patency. To test whether the learning curve for EVH alters conduit integrity owing to increased trauma compared with an open harvest, we analyzed the quality and early patency of conduits procured by technicians with varying EVH experience. Methods During coronary artery bypass grafting, veins were harvested open (n = 10) or by EVH (n = 85) performed by experienced (>900 cases, >30/month) versus novice <100 cases, <3/month) technicians. Harvested conduits were imaged intraoperatively using optical coherence tomography and on day 5 to assess graft patency using computed tomographic angiography. Results Conduits from experienced (n = 55) versus novice (n = 30) harvesters had similar lengths (33 versus 34 cm) and harvest times (32.4 versus 31.8 minutes). Conduit injury was noted in both EVH groups with similar distribution among disruption of the adventitia (62%), intimal tears at branch points (23%), and intimal or medial dissections (15%), but the incidence of these injuries was less with experienced harvesters and rare in veins procured with an open technique. Overall, the rate of graft attrition was similar between the two EVH groups (6.45% versus 4.34% of grafts; p = 0.552). However, vein grafts with at least 4 intimal or medial dissections showed significantly worse patency (67% versus 96% patency; p = 0.05). Conclusions High-resolution imaging confirmed that technicians inexperienced with EVH are more likely to cause intimal and deep vessel injury to the saphenous vein graft, which increases graft failure risk. Endoscopic vein harvest remains the most common technique for conduit harvest, making efforts to better monitor the learning curve an important public health issue. PMID:21524447

  12. Use of nerve conduits for peripheral nerve injury repair: A Web of Science-based literature analysis.

    PubMed

    Nan, Jinniang; Hu, Xuguang; Li, Hongxiu; Zhang, Xiaonong; Piao, Renjing

    2012-12-15

    To identify global research trends in the use of nerve conduits for peripheral nerve injury repair. Numerous basic and clinical studies on nerve conduits for peripheral nerve injury repair were performed between 2002-2011. We performed a bibliometric analysis of the institutions, authors, and hot topics in the field, from the Web of Science, using the key words peripheral nerve and conduit or tube. peer-reviewed published articles on nerve conduits for peripheral nerve injury repair, indexed in the Web of Science; original research articles, reviews, meeting abstracts, proceedings papers, book chapters, editorial material, and news items. articles requiring manual searching or telephone access; documents not published in the public domain; and several corrected papers. (a) Annual publication output; (b) publication type; (c) publication by research field; (d) publication by journal; (e) publication by funding agency; (f) publication by author; (g) publication by country and institution; (h) publications by institution in China; (i) most-cited papers. A total of 793 publications on the use of nerve conduits for peripheral nerve injury repair were retrieved from the Web of Science between 2002-2011. The number of publications gradually increased over the 10-year study period. Articles constituted the main type of publication. The most prolific journals were Biomaterials, Microsurgery, and Journal of Biomedical Materials Research Part A. The National Natural Science Foundation of China supported 27 papers, more than any other funding agency. Of the 793 publications, almost half came from American and Chinese authors and institutions. Nerve conduits have been studied extensively for peripheral nerve regeneration; however, many problems remain in this field, which are difficult for researchers to reach a consensus.

  13. Aortic valve replacement for papillary fibroelastoma.

    PubMed

    Arikan, Ali Ahmet; Omay, Oğuz; Aydın, Fatih; Kanko, Muhip; Gür, Sibel; Derviş, Emir; Yılmaz, Cansu Eda; Müezzinoğlu, Bahar

    2017-06-01

    Surgery is indicated for symptomatic patients with papillary fibroelastomas (PFE) on the aortic valve. The valve is commonly spared during tumor excision. Rarely, aortic valve replacement (AVR) is needed. We present a case requiring AVR for an aortic valve PFE and review the literature to determine the risk factors for failure of aortic valve-sparing techniques in patients with PFE. © 2017 Wiley Periodicals, Inc.

  14. Further Development, Support and Enhancement of CONDUIT

    NASA Technical Reports Server (NTRS)

    Veronica, Moldoveanu; Levine, William S.

    1999-01-01

    From the first airplanes steered by handles, wheels, and pedals to today's advanced aircraft, there has been a century of revolutionary inventions, all of them contributing to flight quality. The stability and controllability of aircraft as they appear to a pilot are called flying or handling qualities. Many years after the first airplanes flew, flying qualities were identified and ranked from desirable to unsatisfactory. Later on engineers developed design methods to satisfy these practical criteria. CONDUIT, which stands for Control Designer's Unified Interface, is a modern software package that provides a methodology for optimization of flight control systems in order to improve the flying qualities. CONDUIT is dependent on an the optimization engine called CONSOL-OPTCAD (C-O). C-O performs multicriterion parametric optimization. C-O was successfully tested on a variety of control problems. The optimization-based computational system, C-O, requires a particular control system description as a MATLAB file and possesses the ability to modify the vector of design parameters in an attempt to satisfy performance objectives and constraints specified by the designer, in a C-type file. After the first optimization attempts on the UH-60A control system, an early interface system, named GIFCORCODE (Graphical Interface for CONSOL-OPTCAD for Rotorcraft Controller Design) was created.

  15. 46 CFR 56.20-9 - Valve construction.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...

  16. 46 CFR 56.20-9 - Valve construction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...

  17. 46 CFR 56.20-9 - Valve construction.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...

  18. 46 CFR 56.20-9 - Valve construction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...

  19. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    NASA Astrophysics Data System (ADS)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  20. Immunohistochemical demonstration of epidermal growth factor in human gastric cancer xenografts of nude mice.

    PubMed

    Yoshiyuki, T; Shimizu, Y; Onda, M; Tokunaga, A; Kiyama, T; Nishi, K; Mizutani, T; Matsukura, N; Tanaka, N; Akimoto, M

    1990-02-15

    Thirty-two surgical specimens and three cell lines of human gastric cancers were used for subcutaneous transplantation into nude mice, resulting in the establishment of eight (25%) xenografts from the surgical specimens and two (67%) from the cell lines. The localization of epidermal growth factor (EGF) in the surgical specimens and cell lines of the gastric cancers and their xenografts in nude mice was then investigated immunohistochemically. Epidermal growth factor was stained in the cytoplasm of the cancer cells, being detected in 16 (50%) of the 32 surgical specimens and in all of the cell lines. Seven (44%) of the sixteen EGF-positive surgical specimens and one (6%) of the 16 EGF-negative ones were tumorigenic in nude mice. All of the xenografts in nude mice were positive for EGF. The tumorigenicity of human gastric cancer xenografts in nude mice may, therefore, be correlated with the presence of EGF in cancer cells.