Sample records for valve disease methods

  1. [Elastic registration method to compute deformation functions for mitral valve].

    PubMed

    Yang, Jinyu; Zhang, Wan; Yin, Ran; Deng, Yuxiao; Wei, Yunfeng; Zeng, Junyi; Wen, Tong; Ding, Lu; Liu, Xiaojian; Li, Yipeng

    2014-10-01

    Mitral valve disease is one of the most popular heart valve diseases. Precise positioning and displaying of the valve characteristics is necessary for the minimally invasive mitral valve repairing procedures. This paper presents a multi-resolution elastic registration method to compute the deformation functions constructed from cubic B-splines in three dimensional ultrasound images, in which the objective functional to be optimized was generated by maximum likelihood method based on the probabilistic distribution of the ultrasound speckle noise. The algorithm was then applied to register the mitral valve voxels. Numerical results proved the effectiveness of the algorithm.

  2. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    PubMed

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  3. Valve Disease

    MedlinePlus

    ... and valves (the endocardium). This is called infective endocarditis. Coronary artery disease Heart attack What are the ... of your heart. This infection is called infective endocarditis . Medicines Medicines are given to ease the pain ...

  4. Aortic valve replacement using continuous suture technique in patients with aortic valve disease.

    PubMed

    Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku

    2013-08-01

    The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

  5. Quantification of mitral valve regurgitation in dogs with degenerative mitral valve disease by use of the proximal isovelocity surface area method.

    PubMed

    Gouni, Vassiliki; Serres, François J; Pouchelon, Jean-Louis; Tissier, Renaud; Lefebvre, Hervé P; Nicolle, Audrey P; Sampedrano, Carolina Carlos; Chetboul, Valérie

    2007-08-01

    To determine the within-day and between-day variability of regurgitant fraction (RF) assessed by use of the proximal isovelocity surface area (PISA) method in awake dogs with degenerative mitral valve disease (MVD), measure RF in dogs with MVD, and assess the correlation between RF and several clinical and Doppler echocardiographic variables. Prospective study. 6 MVD-affected dogs with no clinical signs and 67 dogs with MVD of differing severity (International Small Animal Cardiac Health Council [ISACHC] classification). The 6 dogs were used to determine the repeatability and reproducibility of the PISA method, and RF was then assessed in 67 dogs of various ISACHC classes. Mitral valve regurgitation was also assessed from the maximum area of regurgitant jet signal-to-left atrium area (ARJ/LAA) ratio determined via color Doppler echocardiographic mapping. Within- and between-day coefficients of variation of RF were 8% and 11%, respectively. Regurgitation fraction was significantly correlated with ISACHC classification and heart murmur grade and was higher in ISACHC class III dogs (mean +/- SD, 72.8 +/- 9.5%) than class II (57.9 +/- 20.1%) or I (40.7 +/- 19.2%) dogs. Regurgitation fraction and left atriumto-aorta ratio, fractional shortening, systolic pulmonary arterial pressure, and ARJ/LAA ratio were significantly correlated. Results suggested that RF is a repeatable and reproducible variable for noninvasive quantitative evaluation of mitral valve regurgitation in awake dogs. Regurgitation fraction also correlated well with disease severity. It appears that this Doppler echocardiographic index may be useful in longitudinal studies of MVD in dogs.

  6. Aortic Valve Disease

    MedlinePlus

    ... factors, a physical exam, and with results from tests and procedures. Diagnosis and Treatment Options Diagnosis and Treatment Options There is no one test that can diagnose aortic valve disease, so your ...

  7. A new cannulation method for isolated mitral valve surgery--"apicoaortic-pa" cannulation.

    PubMed

    Wada, J; Komatsu, S; Nakae, S; Kazui, T

    1976-06-01

    The present paper describes experimental and clinical studies of a new method "Apicoaortic-PA" cannulation for mitral valve surgery. Our experimental study showed that this method was more rapid and more physiological for cardiopulmonary bypass. We used this technique in 55 cases of isolated mitral valve surgery with successful results. Our general philosophy of surgical approach to the mitral valve diseases is also discussed. We advocate the utilization of the "Apicoaortic Pulmonary Artery" cannulation method for clinical use in isolated mitral valve surgery through the left thoracotomy.

  8. Intraluminal valves: development, function and disease

    PubMed Central

    Geng, Xin; Cha, Boksik; Mahamud, Md. Riaj

    2017-01-01

    ABSTRACT The circulatory system consists of the heart, blood vessels and lymphatic vessels, which function in parallel to provide nutrients and remove waste from the body. Vascular function depends on valves, which regulate unidirectional fluid flow against gravitational and pressure gradients. Severe valve disorders can cause mortality and some are associated with severe morbidity. Although cardiac valve defects can be treated by valve replacement surgery, no treatment is currently available for valve disorders of the veins and lymphatics. Thus, a better understanding of valves, their development and the progression of valve disease is warranted. In the past decade, molecules that are important for vascular function in humans have been identified, with mouse studies also providing new insights into valve formation and function. Intriguing similarities have recently emerged between the different types of valves concerning their molecular identity, architecture and development. Shear stress generated by fluid flow has also been shown to regulate endothelial cell identity in valves. Here, we review our current understanding of valve development with an emphasis on its mechanobiology and significance to human health, and highlight unanswered questions and translational opportunities. PMID:29125824

  9. Recognizing the Symptoms of Worsening Heart Valve Disease

    MedlinePlus

    ... heart valve disease. Support Network: You're Not Alone Valve Disease Resources Patient Guide: Understanding Your Heart ... Signs of a Heart Attack 5 How to Eat Healthy 6 What are the Symptoms of High ...

  10. Force measuring valve assemblies, systems including such valve assemblies and related methods

    DOEpatents

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  11. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    PubMed

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  12. [Status of aortic valve reconstruction and Ross operation in aortic valve diseases].

    PubMed

    Sievers, Hans H

    2002-08-01

    if these are progressive and combined with aortic insufficiency. ROSS-OPERATION: The Ross-Operation includes the replacement of the diseased aortic valve with the pulmonary autograft and reconstruction of the right ventricular outflow tract using a homograft. The hemodynamic results are excellent regarding the autograft and also the clinical results with very low thromboembolic risk and acceptable reoperation rate. This method is especially indicated for active young patients, women, who desire children, athletes and patients in general, who like to avoid long-term anticoagulation. In some cases the homograft may develop a dysfunction predominantly a pulmonary stenosis requiring reoperation. In the author's series of 245 Ross-operations in 12 years the homograft had to be replaced in 4 cases without letality. Innovative, decellularized homografts with the potential to repopulate with autologeous cells show promising results after 1 year of clinical implantation without signs of antibody development. Probably these tissue-engineered modification may improve the homograft results. The reconstructive techniques of the aortic valve and the Ross-operation have a certain risk of reoperation that must be weighed against the advantages of very low hospital and late valve related death, excellent hemodynamics, very low risk of macro- and microembolism as well as bleeding, lack of long-term anticoagulation and unrestricted life-style.

  13. Pathology of myxomatous mitral valve disease in the dog.

    PubMed

    Fox, Philip R

    2012-03-01

    Mitral valve competence requires complex interplay between structures that comprise the mitral apparatus - the mitral annulus, mitral valve leaflets, chordae tendineae, papillary muscles, and left atrial and left ventricular myocardium. Myxomatous mitral valve degeneration is prevalent in the canine, and most adult dogs develop some degree of mitral valve disease as they age, highlighting the apparent vulnerability of canine heart valves to injury. Myxomatous valvular remodeling is associated with characteristic histopathologic features. Changes include expansion of extracellular matrix with glycosaminoglycans and proteoglycans; valvular interstitial cell alteration; and attenuation or loss of the collagen-laden fibrosa layer. These lead to malformation of the mitral apparatus, biomechanical dysfunction, and mitral incompetence. Mitral regurgitation is the most common manifestation of myxomatous valve disease and in advanced stages, associated volume overload promotes progressive valvular regurgitation, left atrial and left ventricular remodeling, atrial tears, chordal rupture, and congestive heart failure. Future studies are necessary to identify clinical-pathologic correlates that track disease severity and progression, detect valve dysfunction, and facilitate risk stratification. It remains unresolved whether, or to what extent, the pathobiology of myxomatous mitral valve degeneration is the same between breeds of dogs, between canines and humans, and how these features are related to aging and genetics. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Fibrocalcific aortic valve disease: Opportunity to understand disease mechanisms using mouse models

    PubMed Central

    Weiss, Robert M.; Miller, Jordan D.; Heistad, Donald D.

    2013-01-01

    Studies in vitro and in vivo continue to identify complex regulated mechanisms leading to overt fibrocalcific aortic valve disease (FCAVD). Assessment of the functional impact of those processes requires careful studies of models of FCAVD in vivo. Although the genetic basis for FCVAD is unknown for most patients with FCAVD, several disease-associated genes have been identified in humans and mice. Some gene products which regulate valve development in utero also protect against fibro-calcific disease during postnatal aging. Valve calcification can occur via processes that resemble bone formation. But valve calcification can also occur by non-osteogenic mechanisms, such as formation of calcific apoptotic nodules. Anti-calcific interventions might preferentially target either osteogenic or non-osteogenic calcification. Although FCAVD and atherosclerosis share several risk factors and mechanisms, there are fundamental differences between arteries and the aortic valve, with respect to disease mechanisms and responses to therapeutic interventions. Both innate and acquired immunity are likely to contribute to FCAVD. Angiogenesis is a feature of inflammation, but may also contribute independently to progression of FCAVD, possibly by actions of pericytes that are associated with new blood vessels. Several therapeutic interventions appear to be effective in attenuating development of FCAVD in mice. Therapies which are effective early in the course of FCAVD, however, are not necessarily effective in established disease. PMID:23833295

  15. Surgery for rheumatic mitral valve disease in sub-saharan African countries: why valve repair is still the best surgical option.

    PubMed

    Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie

    2016-01-01

    Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.

  16. Loss of Axin2 results in impaired heart valve maturation and subsequent myxomatous valve disease.

    PubMed

    Hulin, Alexia; Moore, Vicky; James, Jeanne M; Yutzey, Katherine E

    2017-01-01

    Myxomatous valve disease (MVD) is the most common aetiology of primary mitral regurgitation. Recent studies suggest that defects in heart valve development can lead to heart valve disease in adults. Wnt/β-catenin signalling is active during heart valve development and has been reported in human MVD. The consequences of increased Wnt/β-catenin signalling due to Axin2 deficiency in postnatal valve remodelling and pathogenesis of MVD were determined. To investigate the role of Wnt/β-catenin signalling, we analysed heart valves from mice deficient in Axin2 (KO), a negative regulator of Wnt/β-catenin signalling. Axin2 KO mice display enlarged mitral and aortic valves (AoV) after birth with increased Wnt/β-catenin signalling and cell proliferation, whereas Sox9 expression and collagen deposition are decreased. At 2 months in Axin2 KO mice, the valve extracellular matrix (ECM) is stratified but distal AoV leaflets remain thickened and develop aortic insufficiency. Progressive myxomatous degeneration is apparent at 4 months with extensive ECM remodelling and focal aggrecan-rich areas, along with increased BMP signalling. Infiltration of inflammatory cells is also observed in Axin2 KO AoV prior to ECM remodelling. Overall, these features are consistent with the progression of human MVD. Finally, Axin2 expression is decreased and Wnt/β-catenin signalling is increased in myxomatous mitral valves in a murine model of Marfan syndrome, supporting the importance of Wnt/β-catenin signalling in the development of MVD. Altogether, these data indicate that Axin2 limits Wnt/β-catenin signalling after birth and allows proper heart valve maturation. Moreover, dysregulation of Wnt/β-catenin signalling resulting from loss of Axin2 leads to progressive MVD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  17. Mechanical valve replacement in congenital heart disease.

    PubMed

    Fiane, A E; Lindberg, H L; Saatvedt, K; Svennevig, J L

    1996-05-01

    Mechanical valves are the prosthesis of choice in valve replacement in children. However, the problem of somatic growth leading to patient-valve mismatch remains present, and the appropriate anticoagulation regimen remains controversial. We present our experience of valve replacement in a young population over 20 years. Between 1972 and 1992, 48 patients (34 males and 14 females), mean age 11.2 years (range 0.4-27.4 years), underwent mechanical valve replacement at our institution. Aortic valve replacement was performed in 28 patients (58.3%), mitral valve replacement in 13 (27.1%), tricuspid valve replacement in six (12.5%) and pulmonary valve replacement in one patient (2.1%). The prostheses used were: St. Jude Medical (n = 2), Björk-Shiley (n = 14), Medtronic Hall (n = 16), Duromedics (n = 2) and CarboMedics (n = 14). Early mortality was 14.3%, 10.7% for aortic valve replacement and 30.8% for mitral valve replacement. Mean follow up for all patients was 8.3 years (range 0-22 years), with a total of 398 patient-years. Seven patients died during the follow up (17.1%). Survival after 10 years, including operative mortality, was 81% for aortic valve replacement, 33% for mitral valve replacement, 83% for tricuspid valve replacement and 100% for pulmonary valve replacement. All patients were anticoagulated with warfarin. In eight patients (16.7%) an antiplatelet drug (aspirin or dipyridamole) was added. Major events included paravalvular leak in six patients (1.5%/pty), valve thrombosis in five (mitral position in two, tricuspid in three) (1.3%/pty) and endocarditis in one patient (0.3%/pty). Minor thromboembolic events occurred in three patients (0.8%/pty) and minor hemorrhagic events in three (0.8%/pty). No patients developed hemolytic anemia and there was no case of structural failure. In our experience, mechanical prostheses in congenital heart disease were associated with significant morbidity and mortality, however long term survival after aortic valve

  18. Underlying Rheumatic Disease: An Important Determinant of Outcome in Tricuspid Valve Repair.

    PubMed

    Munasur, Mandhir; Naidoo, Datshana

    2016-03-01

    Tricuspid regurgitation (TR) accompanying severe left-sided valve disease occurs on a functional basis, secondary to pulmonary hypertension and tricuspid annular dilatation. In the context of endemic left-sided rheumatic heart disease, non-recognition of organic disease of the tricuspid valve may adversely influence surgical decision-making, resulting in suboptimal outcomes. A retrospective analysis of the perioperative and follow up data of 30 patients who underwent tricuspid valve surgery with concomitant left-sided valve replacement was undertaken. Preoperative evaluation by two-dimensional transthoracic echocardiography was routinely employed. Outcomes were analyzed by evaluation of the perioperative and two-year follow up clinical and echocardiographic data. All subjects had severe TR. Mixed tricuspid valve disease occurred in 11 subjects (36.7%). Tricuspid valve repair was performed in 28 patients. A significant improvement (p <0.05) in the following parameters occurred at six weeks postoperatively: NYHA functional class, tricuspid annular diameter, systolic pulmonary artery pressure, severity of TR and tricuspid transvalvular gradient. Severe residual postoperative TR occurred in 26.7% of patients, but there were no identifiable predictors for this phenomenon. Severe residual postoperative TR was not associated with major adverse cardiovascular events. Preoperative (p = 0.013) and postoperative (p<0.002) pulmonary hypertension were associated with the development of major adverse cardiovascular events. The technique of tricuspid valve repair was not associated with the occurrence of major adverse cardiovascular events, nor with the development of severe residual postoperative TR. A satisfactory outcome was observed in only 40% of the study population. The coexistence of mixed tricuspid valve disease in rheumatic heart disease patients undergoing left-sided valve surgery is an important determinant of outcome in tricuspid valve repair. The persistence of

  19. Fabrication of Microfluidic Valves Using a Hydrogel Molding Method

    NASA Astrophysics Data System (ADS)

    Sugiura, Yusuke; Hirama, Hirotada; Torii, Toru

    2015-08-01

    In this paper, a method for fabricating a microfluidic valve made of polydimethylsiloxane (PDMS) using a rapid prototyping method for microchannels through hydrogel cast molding is discussed. Currently, the valves in microchannels play an important role in various microfluidic devices. The technology to prototype microfluidic valves rapidly is actively being developed. For the rapid prototyping of PDMS microchannels, a method that uses a hydrogel as the casting mold has been recently developed. This technique can be used to prepare a three-dimensional structure through simple and uncomplicated methods. In this study, we were able to fabricate microfluidic valves easily using this rapid prototyping method that utilizes hydrogel cast molding. In addition, we confirmed that the valve displacement could be predicted within a range of constant pressures. Moreover, because microfluidic valves fabricated using this method can be directly observed from a cross-sectional direction, we anticipate that this technology will significantly contribute to clarifying fluid behavior and other phenomena in microchannels and microfluidic valves with complex structures.

  20. Fabrication of Microfluidic Valves Using a Hydrogel Molding Method.

    PubMed

    Sugiura, Yusuke; Hirama, Hirotada; Torii, Toru

    2015-08-24

    In this paper, a method for fabricating a microfluidic valve made of polydimethylsiloxane (PDMS) using a rapid prototyping method for microchannels through hydrogel cast molding is discussed. Currently, the valves in microchannels play an important role in various microfluidic devices. The technology to prototype microfluidic valves rapidly is actively being developed. For the rapid prototyping of PDMS microchannels, a method that uses a hydrogel as the casting mold has been recently developed. This technique can be used to prepare a three-dimensional structure through simple and uncomplicated methods. In this study, we were able to fabricate microfluidic valves easily using this rapid prototyping method that utilizes hydrogel cast molding. In addition, we confirmed that the valve displacement could be predicted within a range of constant pressures. Moreover, because microfluidic valves fabricated using this method can be directly observed from a cross-sectional direction, we anticipate that this technology will significantly contribute to clarifying fluid behavior and other phenomena in microchannels and microfluidic valves with complex structures.

  1. Heart Valve Diseases

    MedlinePlus

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  2. Murmur intensity in small-breed dogs with myxomatous mitral valve disease reflects disease severity.

    PubMed

    Ljungvall, I; Rishniw, M; Porciello, F; Ferasin, L; Ohad, D G

    2014-11-01

    To determine whether murmur intensity in small-breed dogs with myxomatous mitral valve disease reflects clinical and echocardiographic disease severity. Retrospective multi-investigator study. Records of adult dogs Ä20 kg with myxomatous mitral valve disease were examined. Murmur intensity and location were recorded and compared with echocardiographic variables and functional disease status. Murmur intensities in consecutive categories were compared for prevalences of congestive heart failure, pulmonary hypertension and cardiac remodelling. 578 dogs [107 with "soft" (30 Grade I/VI and 77 II/VI), 161 with "moderate" (Grade III/VI), 160 with "loud" (Grade IV/VI) and 150 with "thrilling" (Grade V/VI or VI/VI) murmurs] were studied. No dogs with soft murmurs had congestive heart failure, and 90% had no remodelling. However, 56% of dogs with "moderate", 29% of dogs with "loud" and 8% of dogs with "thrilling" murmurs and subclinical myxomatous mitral valve disease also had no remodelling. Probability of a dog having congestive heart failure or pulmonary hypertension increased with increasing murmur intensity. A 4-level murmur grading scheme separated clinically meaningful outcomes in small-breed dogs with myxomatous mitral valve disease. Soft murmurs in small-breed dogs are strongly indicative of subclinical heart disease. Thrilling murmurs are associated with more severe disease. Other murmurs are less informative on an individual basis. © 2014 British Small Animal Veterinary Association.

  3. Should high risk patients with concomitant severe aortic stenosis and mitral valve disease undergo double valve surgery in the TAVR era?

    PubMed

    Yu, Pey-Jen; Mattia, Allan; Cassiere, Hugh A; Esposito, Rick; Manetta, Frank; Kohn, Nina; Hartman, Alan R

    2017-12-29

    Significant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The aim of this study is to determine if surgical correction of both aortic and mitral valves in high risk patients with concomitant valvular disease would offer patients better outcomes than TAVR alone. A retrospective analysis of 43 high-risk patients who underwent concomitant surgical aortic valve replacement and mitral valve surgery from 2008 to 2012 was performed. Immediate and long term survival were assessed. There were 43 high-risk patients with severe aortic stenosis undergoing concomitant surgical aortic valve replacement and mitral valve surgery. The average age was 80 ± 6 years old. Nineteen (44%) patients had prior cardiac surgery, 15 (34.9%) patients had chronic obstructive lung disease, and 39 (91%) patients were in congestive heart failure. The mean Society of Thoracic Surgeons Predicted Risk of Mortality for isolated surgical aortic valve replacement for the cohort was 10.1% ± 6.4%. Five patients (11.6%) died during the index admission and/or within thirty days of surgery. Mortality rate was 25% at six months, 35% at 1 year and 45% at 2 years. There was no correlation between individual preoperative risk factors and mortality. High-risk patients with severe aortic stenosis and mitral valve disease undergoing concomitant surgical aortic valve replacement and mitral valve surgery may have similar long term survival as that described for such patients undergoing TAVR. Surgical correction of double valvular disease in this patient population may not confer mortality benefit compared to TAVR alone.

  4. Non-Dimensional Formulation of Ventricular Work-Load Severity Under Concomitant Heart Valve Disease

    NASA Astrophysics Data System (ADS)

    Dong, Melody; Simon-Walker, Rachael; Dasi, Lakshmi

    2012-11-01

    Current guidelines on assessing the severity of heart valve disease rely on dimensional disease specific measures and are thus unable to capture severity under a concomitant heart valve disease scenario. Experiments were conducted to measure ventricular work-load in an in-house in-vitro left heart simulator. In-house tri-leaflet heart valves were built and parameterized to model concomitant heart valve disease. Measured ventricular power varied non-linearly with cardiac output and mean aortic pressure. Significant data collapse could be achieved by the non-dimensionalization of ventricular power with cardiac output, fluid density, and a length scale. The dimensionless power, Circulation Energy Dissipation Index (CEDI), indicates that concomitant conditions require a significant increase in the amount of work needed to sustain cardiac function. It predicts severity without the need to quantify individual disease severities. This indicates the need for new fluid-dynamics similitude based clinical guidelines to assist patients with multiple heart valve diseases. Funded by the American Heart Association.

  5. Simple versus complex degenerative mitral valve disease.

    PubMed

    Javadikasgari, Hoda; Mihaljevic, Tomislav; Suri, Rakesh M; Svensson, Lars G; Navia, Jose L; Wang, Robert Z; Tappuni, Bassman; Lowry, Ashley M; McCurry, Kenneth R; Blackstone, Eugene H; Desai, Milind Y; Mick, Stephanie L; Gillinov, A Marc

    2018-07-01

    At a center where surgeons favor mitral valve (MV) repair for all subsets of leaflet prolapse, we compared results of patients undergoing repair for simple versus complex degenerative MV disease. From January 1985 to January 2016, 6153 patients underwent primary isolated MV repair for degenerative disease, 3101 patients underwent primary isolated MV repair for simple disease (posterior prolapse), and 3052 patients underwent primary isolated MV repair for complex disease (anterior or bileaflet prolapse), based on preoperative echocardiographic images. Logistic regression analysis was used to generate propensity scores for risk-adjusted comparisons (n = 2065 matched pairs). Durability was assessed by longitudinal recurrence of mitral regurgitation and reoperation. Compared with patients with simple disease, those undergoing repair of complex pathology were more likely to be younger and female (both P values < .0001) but with similar symptoms (P = .3). The most common repair technique was ring/band annuloplasty (3055/99% simple vs 3000/98% complex; P = .5), followed by leaflet resection (2802/90% simple vs 2249/74% complex; P < .0001). Among propensity-matched patients, recurrence of severe mitral regurgitation 10 years after repair was 6.2% for simple pathology versus 11% for complex pathology (P = .007), reoperation at 18 years was 6.3% for simple pathology versus 11% for complex pathology, and 20-year survival was 62% for simple pathology versus 61% for complex pathology (P = .6). Early surgical intervention has become more common in patients with degenerative MV disease, regardless of valve prolapse complexity or symptom status. Valve repair was associated with similarly low operative risk and time-related survival but less durability in complex disease. Lifelong annual echocardiographic surveillance after MV repair is recommended, particularly in patients with complex disease. Copyright © 2018 The American Association for Thoracic Surgery

  6. Artificial chordae for degenerative mitral valve disease: critical analysis of current techniques

    PubMed Central

    Ibrahim, Michael; Rao, Christopher; Athanasiou, Thanos

    2012-01-01

    The surgical repair of degenerative mitral valve disease involves a number of technical points of importance. The use of artificial chordae for the repair of degenerative disease has increased as a part of the move from mitral valve replacement to repair of the mitral valve. The use of artificial chordae provides an alternative to the techniques pioneered by Carpentier (including the quadrangular resection, transfer of native chordae and papillary muscle shortening/plasty), which can be more technically difficult. Despite a growth in their uptake and the indications for their use, a number of challenges remain for the use of artificial chordae in mitral valve repair, particularly in the determination of the correct length to ensure optimal leaflet coaptation. Here, we analyse over 40 techniques described for artificial chordae mitral valve repair in the setting of degenerative disease. PMID:22962321

  7. Clinical outcomes of tricuspid valve repair accompanying left-sided heart disease

    PubMed Central

    Azarnoush, Kasra; Nadeemy, Ahmad S; Pereira, Bruno; Leesar, Massoud A; Lambert, Céline; Azhari, Alaa; Eljezi, Vedat; Dauphin, Nicolas; Geoffroy, Etienne; Camilleri, Lionel

    2017-01-01

    AIM To determine whether the need for additional tricuspid valve repair is an independent risk factor when surgery is required for a left-sided heart disease. METHODS One hundred and eighty patients (68 ± 12 years, 79 males) underwent tricuspid annuoplasty. Cox proportional-hazards regression model for multivariate analysis was performed for variables found significant in univariate analyses. RESULTS Tricuspid regurgitation etiology was functional in 154 cases (86%), organic in 16 cases (9%), and mixed in 10 cases (6%), respectively. Postoperative mortality at 30 days was 11.7%. Mean follow-up was 51.7 mo with survival at 5 years of 73.5%. Risk factors for mortality were acute endocarditis [hazard ratio (HR) = 9.22 (95%CI: 2.87-29.62), P < 0.001], ischemic heart disease requiring myocardial revascularization [HR = 2.79 (1.26-6.20), P = 0.012], and aortic valve stenosis [HR = 2.6 (1.15-5.85), P = 0.021]. Significant predictive factors from univariate analyses were double-valve replacement combined with tricuspid annuloplasty [HR = 2.21 (1.11-4.39), P = 0.003] and preoperatively impaired ejection fraction [HR = 1.98 (1.04-3.92), P = 0.044]. However, successful mitral valve repair showed a protective effect [HR = 0.32 (0.10-0.98), P = 0.046]. Additionally, in instances where tricuspid regurgitation required the need for concomitant tricuspid valve repair, mortality predictor scores such as Euroscore 2 could be shortened to a simple Euroscore-tricuspid comprised of only 7 inputs. The explanation may lie in the fact that significant tricuspid regurgitation following left-sided heart disease represents an independent risk factor encompassing several other factors such as pulmonary arterial hypertension and dyspnea. CONCLUSION Tricuspid annuloplasty should be used more often as a concomitant procedure in the presence of relevant tricuspid regurgitation, although it usually reveals an overly delayed correction of a left-sided heart disease. PMID:29104738

  8. Valve Repair Is Superior to Replacement in Most Patients With Coexisting Degenerative Mitral Valve and Coronary Artery Diseases.

    PubMed

    Javadikasgari, Hoda; Gillinov, A Marc; Idrees, Jay J; Mihaljevic, Tomislav; Suri, Rakesh M; Raza, Sajjad; Houghtaling, Penny L; Svensson, Lars G; Navia, José L; Mick, Stephanie L; Desai, Milind Y; Sabik, Joseph F; Blackstone, Eugene H

    2017-06-01

    For mitral regurgitation (MR) from degenerative mitral disease in patients with coexisting coronary artery disease, the appropriate surgical strategy remains controversial. From 1985 to 2011, 1,071 adults (age 70 ± 9.3 years, 77% men) underwent combined coronary artery bypass grafting and either mitral valve repair (n = 872, 81%) or replacement (n=199, 19%) for degenerative MR. Propensity matching (177 patient pairs, 89% of possible matches) was used to compare early outcomes and time-related recurrence of MR after mitral valve repair, mitral valve reoperation, and mortality. Risk factors for death were identified with multivariable, multiphase hazard-function analysis. Patients undergoing valve replacement were older, with more valve calcification and a higher prevalence of preoperative atrial fibrillation and heart failure (all p < .0001). Among matched pairs, mitral replacement versus repair was associated with higher hospital mortality (5.0% vs 1.0%, p = .0001) and more postoperative renal failure (7.0% vs 3.2%, p = .01), reexplorations for bleeding (6.0% vs 3.1%, p = .05), and respiratory failure (14% vs 4.7%, p < .0001). Of matched patients undergoing repair, 18% had MR above 3+ by 5 years. Mitral valve durability was similar between matched groups, but survival at 15 years was 18% after replacement versus 52% after repair. Nomograms from the multivariable equation revealed that in 94% of cases, 10-year survival was calculated to be higher after repair than after replacement. In patients with coexisting degenerative mitral valve and coronary artery diseases, mitral valve repair is expected to confer a long-term survival advantage over replacement despite some recurrence of MR. When feasible, it is the procedure of choice for these patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    ClinicalTrials.gov

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  10. Failing stentless Bioprostheses in patients with carcinoid heart valve disease.

    PubMed

    Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut

    2015-03-27

    Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.

  11. What Is Heart Valve Disease?

    MedlinePlus

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  12. IL-10 and ET-1 as biomarkers of rheumatic valve disease

    PubMed Central

    Leão, Sydney Correia; Lima, Maria Regina Menezes; do Nascimento, Hertaline Menezes; Octacilio-Silva, Shirlei; Rodrigues, Tania Maria de Andrade

    2014-01-01

    Objective To evaluate the immunological profile and gene expression of endothelin-1 (ET-1) in mitral valves of patients with rheumatic fever originated from a reference service in cardiovascular surgery. Methods This was a quantitative, observational and cross-sectional study. Thirty-five subjects (divided into four groups) participated in the study, 25 patients with chronic rheumatic heart disease and ten control subjects. The mean age of the sample studied was 34.5 years. Seventeen of them (48.58%) were male and 18 (51.42%) were female. Inflammatory cytokines (TNF-α, IL-4 and IL-10) were measured and ten mitral valves of patients who underwent first valve replacement were collected for determination of gene expression of endothelin-1 by real time PCR. Results Among the groups studied (patients vs. controls), there was a statistically significant difference in IL-10 levels (P=0.002), and no differences in other cytokines. Expression of endothelin-1 was observed in 70% of samples. Quantitatively, average of ET-1 expression was 62.85±25.63%. Conclusion Inflammatory cytokine IL-10 participates in the maintenance of chronicity of rheumatic fever in patients who underwent valve replacement and those who are undergoing medical treatment. The expression of endothelin-1 in heart valve lesions in patients undergoing mitral valve replacement confirms its association with inflammatory activity in rheumatic fever. PMID:24896159

  13. Immersed smoothed finite element method for fluid-structure interaction simulation of aortic valves

    NASA Astrophysics Data System (ADS)

    Yao, Jianyao; Liu, G. R.; Narmoneva, Daria A.; Hinton, Robert B.; Zhang, Zhi-Qian

    2012-12-01

    This paper presents a novel numerical method for simulating the fluid-structure interaction (FSI) problems when blood flows over aortic valves. The method uses the immersed boundary/element method and the smoothed finite element method and hence it is termed as IS-FEM. The IS-FEM is a partitioned approach and does not need a body-fitted mesh for FSI simulations. It consists of three main modules: the fluid solver, the solid solver and the FSI force solver. In this work, the blood is modeled as incompressible viscous flow and solved using the characteristic-based-split scheme with FEM for spacial discretization. The leaflets of the aortic valve are modeled as Mooney-Rivlin hyperelastic materials and solved using smoothed finite element method (or S-FEM). The FSI force is calculated on the Lagrangian fictitious fluid mesh that is identical to the moving solid mesh. The octree search and neighbor-to-neighbor schemes are used to detect efficiently the FSI pairs of fluid and solid cells. As an example, a 3D idealized model of aortic valve is modeled, and the opening process of the valve is simulated using the proposed IS-FEM. Numerical results indicate that the IS-FEM can serve as an efficient tool in the study of aortic valve dynamics to reveal the details of stresses in the aortic valves, the flow velocities in the blood, and the shear forces on the interfaces. This tool can also be applied to animal models studying disease processes and may ultimately translate to a new adaptive methods working with magnetic resonance images, leading to improvements on diagnostic and prognostic paradigms, as well as surgical planning, in the care of patients.

  14. Method and apparatus for monitoring motor operated valve motor output torque and power at valve seating

    DOEpatents

    Casada, D.A.

    1996-01-16

    A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization. 14 figs.

  15. Method and apparatus for monitoring motor operated valve motor output torque and power at valve seating

    DOEpatents

    Casada, Donald A.

    1996-01-01

    A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization.

  16. Method of Manufacturing Carbon Fiber Reinforced Carbon Composite Valves

    NASA Technical Reports Server (NTRS)

    Rivers, H. Kevin (Inventor); Ransone, Philip O. (Inventor); Northam, G. Burton (Inventor)

    1998-01-01

    A method for forming a carbon composite valve for internal combustion engines is discussed. The process includes the steps of braiding carbon fiber into a rope thereby forming a cylindrically shaped valve stem portion and continuing to braid said fiber while introducing into the braiding carbon fiber rope a carbon matrix plug having an outer surface in a net shape of a valve head thereby forming a valve head portion. The said carbon matrix plug acting as a mandrel over which said carbon fiber rope is braided, said carbon fiber rope and carbon matrix plug forming a valve head portion suitable for mating with a valve seat; cutting said braided carbon valve stem portion at one end to form a valve tip and cutting said braided carbon fiber after said valve head portion to form a valve face and thus provide a composite valve preform; and densifying said preform by embedding the braided carbon in a matrix of carbon to convert said valve stem portion to a valve stem and said valve head portion to a valve head thereby providing said composite valve.

  17. Molecular and Cellular Aspects of Calcific Aortic Valve Disease

    PubMed Central

    Towler, Dwight A.

    2014-01-01

    Calcific aortic valve disease (CAVD) increasingly afflicts our aging population. One-third of our elderly have echocardiographic or radiological evidence of aortic valve sclerosis (CAVS), an early and subclinical form of CAVD. Age, gender, tobacco use, hypercholesterolemia, hypertension, and type II diabetes all contribute to the risk of disease that has worldwide distribution. Upon progression to its most severe form --- calcific aortic stenosis (CAS) --- CAVD becomes debilitating and devastating, and 2% of individuals over age 60 suffer from CAS to the extent that surgical intervention is required. No effective pharmacotherapies exist for treating those at risk for clinical progression. It is becoming increasingly apparent that a diverse spectrum of cellular and molecular mechanisms converge to regulate valvular calcium load; this is evidenced not only in histopathologic heterogeneity of CAVD but also from the multiplicity of cell types that can participate in valve biomineralization. In this review, we highlight our current understanding of CAVD disease biology, emphasizing molecular and cellular aspects of its regulation. We end by pointing to important biological and clinical questions that must be answered to enable sophisticated disease staging and the development of new strategies to medically treat CAVD. PMID:23833294

  18. Shape-based diagnosis of the aortic valve

    NASA Astrophysics Data System (ADS)

    Ionasec, Razvan Ioan; Tsymbal, Alexey; Vitanovski, Dime; Georgescu, Bogdan; Zhou, S. Kevin; Navab, Nassir; Comaniciu, Dorin

    2009-02-01

    Disorders of the aortic valve represent a common cardiovascular disease and an important public-health problem worldwide. Pathological valves are currently determined from 2D images through elaborate qualitative evalu- ations and complex measurements, potentially inaccurate and tedious to acquire. This paper presents a novel diagnostic method, which identies diseased valves based on 3D geometrical models constructed from volumetric data. A parametric model, which includes relevant anatomic landmarks as well as the aortic root and lea ets, represents the morphology of the aortic valve. Recently developed robust segmentation methods are applied to estimate the patient specic model parameters from end-diastolic cardiac CT volumes. A discriminative distance function, learned from equivalence constraints in the product space of shape coordinates, determines the corresponding pathology class based on the shape information encoded by the model. Experiments on a heterogeneous set of 63 patients aected by various diseases demonstrated the performance of our method with 94% correctly classied valves.

  19. Reliability and construct validity of the Instrument to Measure the Impact of Valve Heart Disease on the Patient's Daily Life

    PubMed Central

    dos Anjos, Daniela Brianne Martins; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista dos Santos; Gallani, Maria Cecília Bueno Jayme

    2016-01-01

    ABSTRACT Objective: evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. Method: data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). Results: as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. Conclusion: the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. PMID:27992024

  20. The structure and material composition of ossified aortic valves identified using a set of scientific methods

    NASA Astrophysics Data System (ADS)

    Zeman, Antonín; Šmíd, Michal; Havelcová, Martina; Coufalová, Lucie; Kučková, Štěpánka; Velčovská, Martina; Hynek, Radovan

    2013-11-01

    Degenerative aortic stenosis has become a common and dangerous disease in recent decades. This disease leads to the mineralization of aortic valves, their gradual thickening and loss of functionality. We studied the detailed assessment of the proportion and composition of inorganic and organic components in the ossified aortic valve, using a set of analytical methods applied in science: polarized light microscopy, scanning electron microscopy, X-ray fluorescence, X-ray diffraction, gas chromatography/mass spectrometry and liquid chromatography-tandem mass spectrometry. The sample valves showed the occurrence of phosphorus and calcium in the form of phosphate and calcium carbonate, hydroxyapatite, fluorapatite and hydroxy-fluorapatite, with varying content of inorganic components from 65 to 90 wt%, and with phased development of degenerative disability. The outer layers of the plaque contained an organic component with peptide bonds, fatty acids, proteins and cholesterol. The results show a correlation between the formation of fluorapatite in aortic valves and in other parts of the human bodies, associated with the formation of bones.

  1. Natural history of aortic valve disease following intervention for rheumatic mitral valve disease.

    PubMed

    Namboodiri, Narayanan; Remash, Krishnan; Tharakan, Jaganmohan A; Shajeem, Othayoth; Nair, Krishnakumar; Titus, Thomas; Ajitkumar, Valaparambil K; Sivasankaran, Sivasubramonian; Krishnamoorthy, Kavassery M; Harikrishnan, Sivadasan P; Harikrishnan, Madhavankutty S; Bijulal, Sasidharan

    2009-01-01

    A significant proportion of patients who require interventions for rheumatic mitral valve (MV) disease have coexisting aortic valve (AV) disease. To date, little is known of the natural history of AV disease in these patients. The details of a cohort of 200 patients (146 females, 54 males; mean age at MV intervention 30.3 +/- 9.9 years) with rheumatic heart disease were retrospectively reviewed. The patients had undergone an index MV intervention (either closed or balloon mitral valvotomy) or MV replacement between 1994 and 1996, and received long-term regular follow up examinations. The clinical and echocardiographic data at entry and at follow up were noted. Patients were allocated to two groups, based on whether the AV disease was absent (group I, n=98) or present (group II, n=102) at baseline. The AV disease was categorized as thickening only (group IIA), isolated aortic regurgitation (AR) (group IIB), or combined aortic stenosis (AS) and AR (group IIC). No patient had isolated AS at baseline. The mean follow up period was 9.3 +/- 1.07 years; during which 10 patients in group I developed new AV disease, which included AV thickening only (n=2), trivial-mild AR (n=7) and mild AS with trivial AR (n=1). Of 16 patients in group IIA, 11 developed isolated AR, and one patient progressed to have mild AS and AR. Among 69 patients in group IIB, 22 (31.9%) developed AS, and all had either mild (n=8) or moderate (n=14) AR with mild AS. Group IIC included 17 patients with mild combined AV disease at baseline, except for moderate AS and moderate AR in one patient each. Among 16 patients with mild AS in group IIC, six progressed to moderate AS and two to severe AS. AR became moderate in 10 patients and severe in one patient. The two patients who progressed to severe AS requiring AV replacement had mild AS at baseline. No patient who developed new combined AV disease had lesions with severity more than mild AS or moderate AR. On logistic regression analysis of the variables

  2. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    PubMed

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Results of Contemporary Valve Surgery in Patients with Carcinoid Heart Disease.

    PubMed

    Kuntze, Thomas; Owais, Tamer; Secknus, Maria-Anna; Kaemmerer, Daniel; Baum, Richard; Girdauskas, Evaldas

    2016-05-01

    Carcinoid tumor is a slow-growing type of neuroendocrine tumor, originating from enterochromaffin cells and secreting mainly serotonin. The diagnosis is based on clinical symptoms, hormone blood levels, radiological and nuclear imaging, and histological confirmation. However, most patients have metastases at the time of diagnosis because the clinical signs often remain unnoticed or are attributed to other abdominal conditions. In up to 50% of patients the endocardium is affected due to a hormonally active tumor profile. The study aim was to report the outcome of surgical treatment in patients with carcinoid heart disease, including the data of radiological and nuclear imaging, histological diagnosis, and follow up information. Between 2008 and 2014, a total of 39 consecutive patients (28 males, 11 females; mean age 66 years; range: 28-84 years) with carcinoid heart syndrome were operated on at the authors' institution. Valvular heart disease was diagnosed with two-dimensional echocardiography. The study population included 26 patients (67%) with severe metastatic disease, who underwent radiotherapy preoperatively, and 13 patients (33%) who were metastasis-free and did not receive preoperative systemic therapy. Follow up was available for all hospital survivors, all of whom underwent serial echocardiographic follow up postoperatively. Adverse cardiac events were defined as cardiac-related death, a need for valvular reintervention, the occurrence of valve prosthesis-related complications, or echocardiographic evidence of new, high-degree valvular dysfunction during follow up. The majority of patients (n = 34; 87%) underwent isolated tricuspid valve replacement, while simultaneous pulmonary valve replacement was performed in five patients (13%). Postoperative complications included reoperation for bleeding in five patients (13%) and new heart block requiring pacemaker implantation in 10 (25%). The in-hospital mortality was 5% (n = 2). The overall survival was 43% at

  4. Progression of Tricuspid Regurgitation after Mitral Valve Replacement for Rheumatic Heart Disease.

    PubMed

    Q Tri, Ho H; Vinh, Pham N

    2017-05-01

    Progression of tricuspid regurgitation (TR) may occur after mitral valve replacement (MVR). The study aim was to define the independent predictors for new severe TR after MVR to treat rheumatic heart disease. A total of 413 patients (177 men, 236 women; mean age 40.9 ± 9.2 years) with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair at the authors' institute between 1995 and 2005, who did not have preoperative severe TR, were followed for at least one year postoperatively. Survival without severe TR was estimated using the Kaplan-Meier method. Independent predictors for new severe TR were identified using multiple Cox regression analysis. During a median follow up of 13 years there were two late deaths, and 46 patients (11.1%) had new severe TR. Survival without severe TR was 88.0 ± 1.7% at 10 years. Independent predictors for new severe TR were preoperative moderate TR (HR 2.401; p = 0.008) and atrial fibrillation (AF) (HR 2.119; p = 0.018). At the most recent follow up, furosemide was used in 23.9% patients with and 7.3% patients without new severe TR (p = 0.001). Patients with new severe TR had larger right ventricles and higher pulmonary artery pressures on echocardiography. Among patients with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair, independent predictors for new severe TR were preoperative moderate TR and AF. New severe TR was associated with increased furosemide use.

  5. A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications.

    PubMed

    Rosa, Benoit; Machaidze, Zurab; Shin, Borami; Manjila, Sunil; Brown, David W; Baird, Christopher W; Mayer, John E; Dupont, Pierre E

    2017-11-01

    This paper provides detailed instructions for constructing low-cost bioprosthetic semilunar valves for animal research and clinical training. This work fills an important gap between existing simulator training valves and clinical valves by providing fully functioning designs that can be employed in ex vivo and in vivo experiments and can also be modified to model valvular disease. Valves are constructed in 4 steps consisting of creating a metal frame, covering it with fabric and attaching a suture ring and leaflets. Computer-aided design files are provided for making the frame from wire or by metal 3D printing. The covering fabric and suturing ring are made from materials readily available in a surgical lab, while the leaflets are made from pericardium. The entire fabrication process is described in figures and in a video. To demonstrate disease modelling, design modifications are described for producing paravalvular leaks, and these valves were evaluated in porcine ex vivo (n = 3) and in vivo (n = 6) experiments. Porcine ex vivo and acute in vivo experiments demonstrate that the valves can replicate the performance of clinical valves for research and training purposes. Surgical implantation is similar, and echocardiograms are comparable to clinical valves. Furthermore, valve leaflet function was satisfactory during acute in vivo tests with little central regurgitation, while the paravalvular leak modifications consistently produced leaks in the desired locations. The detailed design procedure presented here, which includes a tutorial video and computer-aided design files, should be of substantial benefit to researchers developing valve disease models and to clinicians developing realistic valve training systems. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Tricuspid regurgitation in mitral valve disease incidence, prognostic implications, mechanism, and management.

    PubMed

    Shiran, Avinoam; Sagie, Alex

    2009-02-03

    Tricuspid regurgitation (TR) in patients with mitral valve (MV) disease is associated with poor outcome and predicts poor survival, heart failure, and reduced functional capacity. It is common if left untreated after MV replacement mainly in rheumatic patients, but it is also common in patients with ischemic mitral regurgitation. It is less common, however, in those with degenerative mitral regurgitation. It might appear many years after surgery and might not resolve after correcting the MV lesion. Late TR might be caused by prosthetic valve dysfunction, left heart disease, right ventricular (RV) dysfunction and dilation, persistent pulmonary hypertension, chronic atrial fibrillation, or by organic (mainly rheumatic) tricuspid valve disease. Most commonly, late TR is functional and isolated, secondary to tricuspid annular dilation. Outcome of isolated tricuspid valve surgery is poor, because RV dysfunction has already occurred at that point in many patients. MV surgery or balloon valvotomy should be performed before RV dysfunction, severe TR, or advanced heart failure has occurred. Tricuspid annuloplasty with a ring should be performed at the initial MV surgery, and the tricuspid annulus diameter (>or=3.5 cm) is the best criterion for performing the annuloplasty. In this article we will review the current data available for understanding the prognostic implications, mechanism, and management of TR in patients with MV disease.

  7. Association of IL-4 (intron 3) and IL-10 (-1082) gene polymorphisms with risk of mitral valve disease in children with rheumatic heart disease.

    PubMed

    Yousry, Sherif M; Sedky, Yasser; Sobieh, Alaa

    2016-10-01

    Aim Rheumatic heart disease is an inflammatory disease of cardiac tissue. The underlying pathogenic mechanisms highlight a complex interplay of immunological, genetic, and environmental factors. The aim of the present study was to investigate whether IL-4 (intron 3) and IL-10 (-1082) gene polymorphisms could be associated with susceptibility and/or severity of rheumatic heart disease among patients from the Egyptian population. Materials and methods A cohort of 140 Egyptian children with rheumatic heart disease and 100 healthy controls were enrolled in this case-control study. Genotyping for IL-4 (intron 3) and IL-10 (-1082) gene polymorphisms was carried out for all patients using a polymerase chain reaction-based analysis. No significant difference in the distribution of genotypes and allelic frequencies between rheumatic heart disease cases and controls for IL-4 (intron 3) (p=0.17; OR 1.07, 95% CI 0.82-3.74) and IL-10 (-1082) (p=0.49; OR 1.03, 95% CI 0.65-2.71) gene polymorphisms was observed. Further categorisation of patients into mitral valve disease and combined valve disease subgroups showed that cases with mitral valve disease have significantly higher frequency of the RP2 allele of IL-4 (intron 3) (p=0.03; OR 2.98, 95% CI 1.93-6.15) and the G allele of IL-10 (-1082) (p=0.04; OR 2.14, 95% CI 1.62-4.95) when compared with controls. Discussion Our study shows that IL-4 (intron 3) and IL-10 (-1082) gene polymorphisms are not significantly associated with susceptibility to rheumatic heart disease, but they might play a role in the pathogenesis of patients with mitral valve disease.

  8. Comprehensive microRNA profiling reveals potential augmentation of the IL1 pathway in rheumatic heart valve disease.

    PubMed

    Lu, Qiyu; Sun, Yi; Duan, Yuyin; Li, Bin; Xia, Jianming; Yu, Songhua; Zhang, Guimin

    2018-03-16

    Valvular heart disease is a leading cause of cardiovascular mortality, especially in China. More than a half of valvular heart diseases are caused by acute rheumatic fever. microRNA is involved in many physiological and pathological processes. However, the miRNA profile of the rheumatic valvular heart disease is unknown. This research is to discuss microRNAs and their target gene pathways involved in rheumatic heart valve disease. Serum miRNA from one healthy individual and four rheumatic heart disease patients were sequenced. Specific differentially expressed miRNAs were quantified by Q-PCR in 40 patients, with 20 low-to-moderate rheumatic mitral valve stenosis patients and 20 severe mitral valve stenosis patients. The target relationship between certain miRNA and predicted target genes were analysis by Luciferase reporter assay. The IL-1β and IL1R1 expression levels were analyzed by immunohistochemistry and western blot in the mitral valve from surgery of mitral valve replacement. The results showed that 13 and 91 miRNAs were commonly upregulated or downregulated in all four patients. Nine miRNAs, 1 upregulated and 8 downregulated, that had a similar fold change in all 4 patients were selected for quantitative PCR verification. The results showed similar results from miRNA sequencing. Within these 9 tested miRNAs, hsa-miR-205-3p and hsa-miR-3909 showed a low degree of dispersion between the members of each group. Hsa miR-205-3p and hsa-miR-3909 were predicted to target the 3'UTR of IL-1β and IL1R1 respectively. This was verified by luciferase reporter assays. Immunohistochemistry and Western blot results showed that the mitral valve from rheumatic valve heart disease showed higher levels of IL- 1β and IL1R1 expression compared with congenital heart valve disease. This suggested a difference between rheumatic heart valve disease and other types of heart valve diseases, with more inflammatory responses in the former. In the present study, by next generation

  9. Management of mitral regurgitation in Marfan syndrome: Outcomes of valve repair versus replacement and comparison with myxomatous mitral valve disease.

    PubMed

    Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M

    2014-09-01

    The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. Rheumatic Heart Disease and Myxomatous Degeneration: Differences and Similarities of Valve Damage Resulting from Autoimmune Reactions and Matrix Disorganization.

    PubMed

    Martins, Carlo de Oliveira; Demarchi, Lea; Ferreira, Frederico Moraes; Pomerantzeff, Pablo Maria Alberto; Brandao, Carlos; Sampaio, Roney Orismar; Spina, Guilherme Sobreira; Kalil, Jorge; Cunha-Neto, Edecio; Guilherme, Luiza

    2017-01-01

    Autoimmune inflammatory reactions leading to rheumatic fever (RF) and rheumatic heart disease (RHD) result from untreated Streptococcus pyogenes throat infections in individuals who exhibit genetic susceptibility. Immune effector mechanisms have been described that lead to heart tissue damage culminating in mitral and aortic valve dysfunctions. In myxomatous valve degeneration (MXD), the mitral valve is also damaged due to non-inflammatory mechanisms. Both diseases are characterized by structural valve disarray and a previous proteomic analysis of them has disclosed a distinct profile of matrix/structural proteins differentially expressed. Given their relevance in organizing valve tissue, we quantitatively evaluated the expression of vimentin, collagen VI, lumican, and vitronectin as well as performed immunohistochemical analysis of their distribution in valve tissue lesions of patients in both diseases. We identified abundant expression of two isoforms of vimentin (45 kDa, 42 kDa) with reduced expression of the full-size protein (54 kDa) in RHD valves. We also found increased vitronectin expression, reduced collagen VI expression and similar lumican expression between RHD and MXD valves. Immunohistochemical analysis indicated disrupted patterns of these proteins in myxomatous degeneration valves and disorganized distribution in rheumatic heart disease valves that correlated with clinical manifestations such as valve regurgitation or stenosis. Confocal microscopy analysis revealed a diverse pattern of distribution of collagen VI and lumican into RHD and MXD valves. Altogether, these results demonstrated distinct patterns of altered valve expression and tissue distribution/organization of structural/matrix proteins that play important pathophysiological roles in both valve diseases.

  11. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    NASA Technical Reports Server (NTRS)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  12. Detection and quantification of angiogenesis in experimental valve disease with integrin-targeted nanoparticles and 19-fluorine MRI/MRS

    PubMed Central

    Waters, Emily A; Chen, Junjie; Allen, John S; Zhang, Huiying; Lanza, Gregory M; Wickline, Samuel A

    2008-01-01

    Background Angiogenesis is a critical early feature of atherosclerotic plaque development and may also feature prominently in the pathogenesis of aortic valve stenosis. It has been shown that MRI can detect and quantify specific molecules of interest expressed in cardiovascular disease and cancer by measuring the unique fluorine signature of appropriately targeted perfluorocarbon (PFC) nanoparticles. In this study, we demonstrated specific binding of ανβ3 integrin targeted nanoparticles to neovasculature in a rabbit model of aortic valve disease. We also showed that fluorine MRI could be used to detect and quantify the development of neovasculature in the excised aortic valve leaflets. Methods New Zealand White rabbits consumed a cholesterol diet for ~180 days and developed aortic valve thickening, inflammation, and angiogenesis mimicking early human aortic valve disease. Rabbits (n = 7) were treated with ανβ3 integrin targeted PFC nanoparticles or control untargeted PFC nanoparticles (n = 6). Competitive inhibition in vivo of nanoparticle binding (n = 4) was tested by pretreatment with targeted nonfluorinated nanoparticles followed 2 hours later by targeted PFC nanoparticles. 2 hours after treatment, aortic valves were excised and 19F MRS was performed at 11.7T. Integrated 19F spectral peaks were compared using a one-way ANOVA and Hsu's MCB (multiple comparisons with the best) post hoc t test. In 3 additional rabbits treated with ανβ3 integrin targeted PFC nanoparticles, 19F spectroscopy was performed on a 3.0T clinical scanner. The presence of angiogenesis was confirmed by immunohistochemistry. Results Valves of rabbits treated with targeted PFC nanoparticles had 220% more fluorine signal than valves of rabbits treated with untargeted PFC nanoparticles (p < 0.001). Pretreatment of rabbits with targeted oil-based nonsignaling nanoparticles reduced the fluorine signal by 42% due to competitive inhibition, to a level not significantly different from control

  13. Recovery of atrial function after atrial compartment operation for chronic atrial fibrillation in mitral valve disease.

    PubMed

    Shyu, K G; Cheng, J J; Chen, J J; Lin, J L; Lin, F Y; Tseng, Y Z; Kuan, P; Lien, W P

    1994-08-01

    We prospectively studied the recovery of atrial function after atrial compartment operation and mitral valve surgery in patients with chronic atrial fibrillation caused by mitral valve disease. Chronic atrial fibrillation is the most common arrhythmia in mitral valve disease. This arrhythmia is associated with excessive morbidity and mortality. Mitral valve surgery alone rarely eliminates it. Twenty-two patients underwent mitral valve surgery and a new surgical method, atrial compartment operation. Doppler echocardiography was performed in all patients before operation and at 1 week and 2 and 6 months after operation in the successful cardioversion group. Peak early diastolic (E) and atrial (A) filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves were measured. Sinus rhythm was restored immediately after operation in 91% of patients and was maintained for > 1 week in 15 (68%) of 22 patients and > 6 months in 14 (64%) of 22. Eleven of 15 patients had left atrial paralysis (A/E integral ratio 0) at 1 week and 6 of 14 patients at 2 months. Nine of 15 patients had right atrial paralysis (A/E integral ratio 0) at 1 week and 1 of 14 patients at 2 months. Both left and right atrial contractile function (presence of an A wave on Doppler findings) was detected at 6 months in 14 patients. Mean (+/- SD) peak atrial filling velocity of the mitral valve was 15 +/- 26 cm/s at 1 week, 38 +/- 39 cm/s at 2 months and 93 +/- 32 cm/s at 6 months (p < 0.001). Mean peak atrial filling velocity of the tricuspid valve was 14 +/- 19 cm/s at 1 week, 33 +/- 19 cm/s at 2 months and 50 +/- 19 cm/s at 6 months (p < 0.001). Peak early diastolic and atrial filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves increased significantly from 1 week to 6 months. Chronic atrial fibrillation in mitral valve disease can often be eliminated by atrial compartment operation. No surgical mortality or significant

  14. Engine including hydraulically actuated valvetrain and method of valve overlap control

    DOEpatents

    Cowgill, Joel [White Lake, MI

    2012-05-08

    An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

  15. Long-term Outcomes of Mitral Valve Repair Versus Replacement for Degenerative Disease: A Systematic Review

    PubMed Central

    McNeely, Christian A; Vassileva, Christina M

    2015-01-01

    The short-term advantage of mitral valve repair versus replacement for degenerative disease has been extensively documented. These advantages include lower operative mortality, improved survival, better preservation of left-ventricular function, shorter post-operative hospital stay, lower total costs, and fewer valve-related complications, including thromboembolism, anticoagulation-related bleeding events and late prosthetic dysfunction. More recent written data are available indicating the long-term advantage of repair versus replacement. While at some institutions, the repair rate for degenerative disease may exceed 90%, the national average in 2007 was only 69%. Making direct comparisons between mitral valve repair and replacement using the available studies does present some challenges however, as there are often differences in baseline characteristics between patient groups as well as other dissimilarities between studies. The purpose of this review is to systematically summarize the long-term survival and reoperation data of mitral valve repair versus replacement for degenerative disease. A PubMed search was done and resulted in 12 studies that met our study criteria for comparing mitral valve repair versus replacement for degenerative disease. A systematic review was then conducted abstracting survival and reoperation data. PMID:25158683

  16. Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management.

    PubMed

    Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard

    2015-09-01

    Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications. The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Precise and modern diagnostic methods

  17. Tricuspid regurgitation and right ventricular function after mitral valve surgery with or without concomitant tricuspid valve procedure

    PubMed Central

    Desai, Ravi R.; Vargas Abello, Lina Maria; Klein, Allan L.; Marwick, Thomas H.; Krasuski, Richard A.; Ye, Ying; Nowicki, Edward R.; Rajeswaran, Jeevanantham; Blackstone, Eugene H.; Pettersson, Gösta B.

    2014-01-01

    Objectives To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. Methods From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+(100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. Results In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. Conclusions In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and

  18. Problem: Heart Valve Stenosis

    MedlinePlus

    ... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...

  19. Cardiac Hemodynamics in the Pathogenesis of Congenital Heart Disease and Aortic Valve Calcification

    NASA Astrophysics Data System (ADS)

    Nigam, Vishal

    2011-11-01

    An improved understanding of the roles of hemodynamic forces play in cardiac development and the pathogenesis of cardiac disease will have significant scientific and clinical impact. I will focus on the role of fluid dynamics in congenital heart disease and aortic valve calcification. Congenital heart defects are the most common form of birth defect. Aortic valve calcification/stenosis is the third leading cause of adult heart disease and the most common form of acquired valvular disease in developed countries. Given the high incidence of these diseases and their associated morbidity and mortality, the potential translational impact of an improved understanding of cardiac hemodynamic forces is very large. Division of Pediatric Cardiology, Rady Children's Hospital, San Diego

  20. Review of Diagnostic and Therapeutic Approach to Canine Myxomatous Mitral Valve Disease

    PubMed Central

    Borgarelli, Michele

    2017-01-01

    The most common heart disease that affects dogs is myxomatous mitral valve disease. In this article, we review the current diagnostic and therapeutic approaches to this disease, and we also present some of the latest technological advancements in this field. PMID:29056705

  1. Artificial aortic valve dysfunction due to pannus and thrombus – different methods of cardiac surgical management

    PubMed Central

    Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard

    2015-01-01

    Introduction Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. Case study 1 The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs’ surface was found. A biological aortic prosthesis was reimplanted without complications. Case study 2 The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored

  2. Prior oral conditions in patients undergoing heart valve surgery

    PubMed Central

    Gil-Raga, Irene; Martinez-Herrera, Mayte; Lauritano, Dorina; Silvestre-Rangil, Javier

    2017-01-01

    Background Patients scheduled for heart valve surgery should be free of any oral infectious disorders that might pose a risk in the postoperative period. Few studies have been made on the dental conditions of such patients prior to surgery. The present study describes the most frequent prior oral diseases in this population group. Material and Methods A prospective, observational case-control study was designed involving 60 patients (30 with heart valve disease and 30 controls, with a mean age of 71 years in both groups). A dental exploration was carried out, with calculation of the DMFT (decayed, missing and filled teeth) index and recording of the periodontal parameters (plaque index, gingival bleeding index, periodontal pocket depth, and attachment loss). The oral mucosa was also examined, and panoramic X-rays were used to identify possible intrabony lesions. Results Significant differences in bacterial plaque index were observed between the two groups (p<0.05), with higher scores in the patients with valve disease. Probing depth and the presence of moderate pockets were also greater in the patients with valve disease than among the controls (p<0.01). Sixty percent of the patients with valve disease presented periodontitis. Conclusions Patients scheduled for heart valve surgery should be examined for possible active periodontitis before the operation. Those individuals found to have periodontal disease should receive adequate periodontal treatment before heart surgery. Key words:Valve disease, aortic, mitral, heart surgery, periodontitis. PMID:29302279

  3. Fluid mechanics of heart valves.

    PubMed

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  4. Clinical Significance of Markers of Collagen Metabolism in Rheumatic Mitral Valve Disease

    PubMed Central

    Banerjee, Tanima; Mukherjee, Somaditya; Ghosh, Sudip; Biswas, Monodeep; Dutta, Santanu; Pattari, Sanjib; Chatterjee, Shelly; Bandyopadhyay, Arun

    2014-01-01

    Background Rheumatic Heart Disease (RHD), a chronic acquired heart disorder results from Acute Rheumatic Fever. It is a major public health concern in developing countries. In RHD, mostly the valves get affected. The present study investigated whether extracellular matrix remodelling in rheumatic valve leads to altered levels of collagen metabolism markers and if such markers can be clinically used to diagnose or monitor disease progression. Methodology This is a case control study comprising 118 subjects. It included 77 cases and 41 healthy controls. Cases were classified into two groups- Mitral Stenosis (MS) and Mitral Regurgitation (MR). Carboxy-terminal propeptide of type I procollagen (PICP), amino-terminal propeptide of type III procollagen (PIIINP), total Matrix Metalloproteinase-1(MMP-1) and Tissue Inhibitor of Metalloproteinase-1 (TIMP-1) were assessed. Histopathology studies were performed on excised mitral valve leaflets. A p value <0.05 was considered statistically significant. Results Plasma PICP and PIIINP concentrations increased significantly (p<0.01) in MS and MR subjects compared to controls but decreased gradually over a one year period post mitral valve replacement (p<0.05). In MS, PICP level and MMP-1/TIMP-1 ratio strongly correlated with mitral valve area (r = −0.40; r = 0.49 respectively) and pulmonary artery systolic pressure (r = 0.49; r = −0.49 respectively); while in MR they correlated with left ventricular internal diastolic (r = 0.68; r = −0.48 respectively) and systolic diameters (r = 0.65; r = −0.55 respectively). Receiver operating characteristic curve analysis established PICP as a better marker (AUC = 0.95; 95% CI = 0.91−0.99; p<0.0001). A cut-off >459 ng/mL for PICP provided 91% sensitivity, 90% specificity and a likelihood ratio of 9 in diagnosing RHD. Histopathology analysis revealed inflammation, scarring, neovascularisation and extensive leaflet fibrosis in diseased mitral

  5. Cardiac Computed Tomography and Magnetic Resonance Imaging in the Evaluation of Mitral and Tricuspid Valve Disease: Implications for Transcatheter Interventions.

    PubMed

    Naoum, Christopher; Blanke, Philipp; Cavalcante, João L; Leipsic, Jonathon

    2017-03-01

    Transcatheter interventions to treat mitral and tricuspid valve disease are becoming increasingly available because of the growing number of elderly patients with significant comorbidities or high operative risk. Thorough clinical and imaging evaluation in these patients is essential. The latter involves both characterization of the mechanism and severity of valvular disease as well as determining the hemodynamic consequences and extent of ventricular remodeling, which is an important predictor of future outcomes. Moreover, an assessment of the suitability and risk of complications associated with device-specific therapies is also an important component of the preprocedural evaluation in this cohort. Although echocardiography including 2-dimensional and 3-dimensional methods has an important role in the initial assessment and procedural guidance, cross-sectional imaging, including both computed tomographic imagning and cardiac magnetic resonance imaging, is increasingly being integrated into the evaluation of mitral and tricuspid valve disease. In this review, we discuss the role of cross-sectional imaging in mitral and tricuspid valve disease, primarily valvular regurgitation assessment, with an emphasis on the preprocedural evaluation and implications for transcatheter interventions. © 2017 American Heart Association, Inc.

  6. Update of transcatheter valve treatment

    PubMed Central

    Liu, Xian-bao; Wang, Jian-an

    2013-01-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair—MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed. PMID:23897785

  7. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.

    PubMed

    Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  8. Heart valve disease associated with treatment with ergot-derived dopamine agonists: a clinical and echocardiographic study of patients with Parkinson's disease.

    PubMed

    Rasmussen, V G; Poulsen, S H; Dupont, E; Østergaard, K; Safikhany, G; Egeblad, H

    2008-01-01

    To elucidate the association between treatment with ergot-derived dopamine agonists (EDDA) and valvular abnormalities amongst patients with idiopathic Parkinson's disease (IPD) and secondly, to analyse the yield of clinical screening for valvular heart disease. A cross-sectional controlled study. The cohort of IPD patients treated in the outpatient clinic, Department of Neurology, Aarhus University Hospital, Denmark. A total of 138 IPD patients [median age 64 (39-87) years, 62% men] treated with either EDDA (n = 85) or non-EDDA (n = 53) for at least 6 months. Interventions. Patients were screened for valvular heart disease by clinical means and by examiner-blinded echocardiography. Main outcome measure was valvular regurgitation revealed by echocardiography. Severe aortic regurgitation (n = 4) or moderate aortic (n = 12), mitral (n = 3) or tricuspidal valve regurgitation (n = 5) was found in 22 EDDA patients (25.9%). Two patients had coexistent moderate mitral and tricuspid valvular regurgitation. Two non-EDDA patients had moderate valve insufficiency (3.8%, P < 0.05). The adjusted relative risk for at least moderate valve insufficiency in the EDDA patients was 7.2% (P < 0.05). The sensitivity of detecting at least moderate valvular disease by cardiac murmur, dyspnoea, or the heart failure marker NT-proBNP (natriuretic peptide) was 62% for the neurologists and 93% for the cardiologist but with equally low specificity (30-35%). EDDA was associated with a clinically important and statistically significant risk of at least moderate valve regurgitation. Clinical screening for valve disease was inadequate and it seems advisable to offer EDDA patients control with echocardiography.

  9. Transcatheter aortic valve-in-valve implantation for severe bioprosthetic stenosis after Bentall operation using a homograft in a patient with Behçet's disease.

    PubMed

    Joo, Hyung Joon; Hong, Soon Jun; Yu, Cheol Woong

    2015-03-01

    A 43-year-old man presented with severe aortic stenosis. Eight years previously, he had undergone primary surgical aortic valve replacement (AVR) for severe aortic regurgitation, but one year later developed cardiac arrest and complete atrioventricular block as a result of non-bacterial thrombotic endocarditis with severe valvular dehiscence. Following the diagnosis of prosthetic valve failure caused by Behçet's disease, the patient underwent a Bentall operation using 23 mm aortic homograft with permanent pacemaker implantation and coronary artery bypass grafting. Subsequently, he was stable with steroid administration and azathioprine for seven years after the second operation, but recently suffered from severe dyspnea and chest pain. Echocardiography revealed the development of severe aortic stenosis. A preprocedural evaluation demonstrated a porcelain aorta with severe calcification in the previous homograft valve on computed tomography, and critical stenosis at the ostium of the left circumflex artery on coronary angiography. After percutaneous coronary intervention for the ostium of the left circumflex artery, a transcatheter AVR was successfully performed using a 26 mm Edwards SAPIEN XT valve. The patient recovered without any complications after the procedure. This is the first report of a successful transcatheter aortic valve-in valve implantation for severe homograft aortic stenosis after a Bentall operation, using a homograft, in a patient with Behçet's disease.

  10. A review of outcome following valve surgery for rheumatic heart disease in Australia.

    PubMed

    Russell, E Anne; Tran, Lavinia; Baker, Robert A; Bennetts, Jayme S; Brown, Alex; Reid, Christopher M; Tam, Robert; Walsh, Warren F; Maguire, Graeme P

    2015-09-23

    Globally, rheumatic heart disease (RHD) remains an important cause of heart disease. In Australia it particularly affects younger Indigenous and older non-Indigenous Australians. Despite its impact there is limited understanding of the factors influencing outcome following surgery for RHD. The Australian and New Zealand Society of Cardiac and Thoracic Surgeons Cardiac Surgery Database was analysed to assess outcomes following surgical procedures for RHD and non-RHD valvular disease. The association with demographics, co-morbidities, pre-operative status, valve(s) affected and operative procedure was evaluated. Outcome of 1384 RHD and 15843 non-RHD valve procedures was analysed. RHD patients had longer ventilation, experienced fewer strokes and had more readmissions to hospital and anticoagulant complications. Mortality following RHD surgery at 30 days was 3.1% (95% CI 2.2 - 4.3), 5 years 15.3% (11.7 - 19.5) and 10 years 25.0% (10.7 - 44.9). Mortality following non-RHD surgery at 30 days was 4.3% (95% CI 3.9 - 4.6), 5 years 17.6% (16.4 - 18.9) and 10 years 39.4% (33.0 - 46.1). Factors independently associated with poorer longer term survival following RHD surgery included older age (OR1.03/additional year, 95% CI 1.01 - 1.05), concomitant diabetes (OR 1.7, 95% CI 1.1 - 2.5) and chronic kidney disease (1.9, 1.2 - 2.9), longer invasive ventilation time (OR 1.7 if greater than median value, 1.1- 2.9) and prolonged stay in hospital (1.02/additional day, 1.01 - 1.03). Survival in Indigenous Australians was comparable to that seen in non-Indigenous Australians. In a large prospective cohort study we have demonstrated survival following RHD valve surgery in Australia is comparable to earlier studies. Patients with diabetes and chronic kidney disease, were at particular risk of poorer long-term survival. Unlike earlier studies we did not find pre-existing atrial fibrillation, being an Indigenous Australian or the nature of the underlying valve lesion were independent

  11. JenaValve.

    PubMed

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  12. High pressure capillary micro-fluidic valve device and a method of fabricating same

    DOEpatents

    Crocker, Robert W [Fremont, CA; Caton, Pamela F [Berkely, CA; Gerhardt, Geoff C [Milbury, MA

    2007-04-17

    A freeze-thaw valve and a method of micro-machining the freeze-thaw valve is provided and includes a valve housing, wherein the valve housing defines a housing cavity and includes a housing inlet, a housing vent, a capillary tubing inlet and a capillary tubing outlet. A valve body is provided, at least a portion of which is lithographically constructed, wherein the valve body includes a refrigerant inlet, a refrigerant outlet and an expansion chamber. The expansion chamber is disposed to communicate the refrigerant inlet with the refrigerant outlet and includes a restriction region having a flow restriction. Additionally, the valve body is disposed within the housing cavity to form an insulating channel between the valve housing and the valve body.

  13. When a Heart Murmur Signals Valve Disease

    MedlinePlus

    ... in adults may be related to: Valve calcification Endocarditis Rheumatic fever In children, abnormal heart murmurs may ... Problem: Pulmonary Valve Regurgitation Heart Valves and Infective Endocarditis Left Ventricular Hypertrophy • Risks, Signs and Symptoms • Accurate ...

  14. Parameter tuning method for dither compensation of a pneumatic proportional valve with friction

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Song, Yang; Huang, Leisheng; Fan, Wei

    2016-05-01

    In the practical application of pneumatic control devices, the nonlinearity of a pneumatic control valve become the main factor affecting the control effect, which comes mainly from the dynamic friction force. The dynamic friction inside the valve may cause hysteresis and a dead zone. In this paper, a dither compensation mechanism is proposed to reduce negative effects on the basis of analyzing the mechanism of friction force. The specific dither signal (using a sinusoidal signal) was superimposed on the control signal of the valve. Based on the relationship between the parameters of the dither signal and the inherent characteristics of the proportional servo valve, a parameter tuning method was proposed, which uses a displacement sensor to measure the maximum static friction inside the valve. According to the experimental results, the proper amplitude ranges are determined for different pressures. In order to get the optimal parameters of the dither signal, some dither compensation experiments have been carried out on different signal amplitude and gas pressure conditions. Optimal parameters are determined under two kinds of pressure conditions. Using tuning parameters the valve spool displacement experiment has been taken. From the experiment results, hysteresis of the proportional servo valve is significantly reduced. And through simulation and experiments, the cut-off frequency of the proportional valve has also been widened. Therefore after adding the dither signal, the static and dynamic characteristics of the proportional valve are both improved to a certain degree. This research proposes a parameter tuning method of dither signal, and the validity of the method is verified experimentally.

  15. How to Make a Heart Valve: From Embryonic Development to Bioengineering of Living Valve Substitutes

    PubMed Central

    MacGrogan, Donal; Luxán, Guillermo; Driessen-Mol, Anita; Bouten, Carlijn; Baaijens, Frank; de la Pompa, José Luis

    2014-01-01

    Cardiac valve disease is a significant cause of ill health and death worldwide, and valve replacement remains one of the most common cardiac interventions in high-income economies. Despite major advances in surgical treatment, long-term therapy remains inadequate because none of the current valve substitutes have the potential for remodeling, regeneration, and growth of native structures. Valve development is coordinated by a complex interplay of signaling pathways and environmental cues that cause disease when perturbed. Cardiac valves develop from endocardial cushions that become populated by valve precursor mesenchyme formed by an epithelial–mesenchymal transition (EMT). The mesenchymal precursors, subsequently, undergo directed growth, characterized by cellular compartmentalization and layering of a structured extracellular matrix (ECM). Knowledge gained from research into the development of cardiac valves is driving exploration into valve biomechanics and tissue engineering directed at creating novel valve substitutes endowed with native form and function. PMID:25368013

  16. Collagen organization in canine myxomatous mitral valve disease: an x-ray diffraction study.

    PubMed

    Hadian, Mojtaba; Corcoran, Brendan M; Han, Richard I; Grossmann, J Günter; Bradshaw, Jeremy P

    2007-10-01

    Collagen fibrils, a major component of mitral valve leaflets, play an important role in defining shape and providing mechanical strength and flexibility. Histopathological studies show that collagen fibrils undergo dramatic changes in the course of myxomatous mitral valve disease in both dogs and humans. However, little is known about the detailed organization of collagen in this disease. This study was designed to analyze and compare collagen fibril organization in healthy and lesional areas of myxomatous mitral valves of dogs, using synchrotron small-angle x-ray diffraction. The orientation, density, and alignment of collagen fibrils were mapped across six different valves. The findings reveal a preferred collagen alignment in the main body of the leaflets between two commissures. Qualitative and quantitative analysis of the data showed significant differences between affected and lesion-free areas in terms of collagen content, fibril alignment, and total tissue volume. Regression analysis of the amount of collagen compared to the total tissue content at each point revealed a significant relationship between these two parameters in lesion-free but not in affected areas. This is the first time this technique has been used to map collagen fibrils in cardiac tissue; the findings have important applications to human cardiology.

  17. Molecular Analysis of Oral Bacteria in Heart Valve of Patients With Cardiovascular Disease by Real-Time Polymerase Chain Reaction

    PubMed Central

    Oliveira, Francisco Artur Forte; Forte, Clarissa Pessoa Fernandes; Silva, Paulo Goberlânio de Barros; Lopes, Camile B.; Montenegro, Raquel Carvalho; dos Santos, Ândrea Kely Campos Ribeiro; Sobrinho, Carlos Roberto Martins Rodrigues; Mota, Mário Rogério Lima; Sousa, Fabrício Bitu; Alves, Ana Paula Negreiros Nunes

    2015-01-01

    Abstract Structural deficiencies and functional abnormalities of heart valves represent an important cause of cardiovascular morbidity and mortality, and a number of diseases, such as aortic stenosis, have been recently associated with infectious agents. This study aimed to analyze oral bacteria in dental plaque, saliva, and cardiac valves of patients with cardiovascular disease. Samples of supragingival plaque, subgingival plaque, saliva, and cardiac valve tissue were collected from 42 patients with heart valve disease. Molecular analysis of Streptococcus mutans, Prevotella intermedia, Porphyromonas gingivalis, and Treponema denticola was performed through real-time PCR. The micro-organism most frequently detected in heart valve samples was the S. mutans (89.3%), followed by P. intermedia (19.1%), P. gingivalis (4.2%), and T. denticola (2.1%). The mean decayed, missing, filled teeth (DMFT) was 26.4 ± 6.9 (mean ± SD), and according to the highest score of periodontal disease observed for each patient, periodontal pockets > 4 mm and dental calculus were detected in 43.4% and 34.7% of patients, respectively. In conclusion, oral bacteria, especially S. mutans, were found in the cardiac valve samples of patients with a high rate of caries and gingivitis/periodontitis. PMID:26632711

  18. Mitral valve disease—morphology and mechanisms

    PubMed Central

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  19. A retrospective study of clinical signs and epidemiology of chronic valve disease in a group of 207 Dachshunds in Poland

    PubMed Central

    2013-01-01

    Background Chronic mitral valve disease is frequently seen in the Dachshund. Dachshunds (n=207) made up 11.73% of the dogs admitted to the Cardiology Service at the Small Animal Clinic, Warsaw University of Life Sciences, Poland (first visits only). Results Of these, 35 dogs had no clinically detectable heart disease while 172 had chronic valve disease with the mitral valve affected most often (130 dogs), both mitral and tricuspid valves infrequently (39 dogs) and rarely the tricuspid valve (3 dogs). Males were affected more frequently than females and the average age of dogs with chronic valve disease was 11.9 years for females and 11.3 years for males. A majority of the diseased Dachshunds were classified as ISACHC 2 (79), followed by ISACHC 1 (60). Most frequent clinical signs noted by owners included coughing, exercise intolerance, dyspnea and tachypnea. Heart murmurs were generally louder with increased disease severity; however there were 20 dogs in the ISACHC 1 group with no audible heart murmurs. The most frequent electrocardiographic abnormalities included an increased P wave and QRS complex duration, increased R wave amplitude and tachycardia. With increased disease severity, echocardiography revealed an increase in heart size. A higher ISACHC class was related to increased heart size (based on echocardiography) and increased percentage of patients exhibiting enlargement of both left atrium and left ventricle (based on radiography). Conclusions The Dachshund is often affected by chronic mitral valvular disease with a late onset of associated clinical signs and few cardiac complications. PMID:23844824

  20. Serum magnesium, phosphorus, and calcium levels and subclinical calcific aortic valve disease: A population-based study.

    PubMed

    Hisamatsu, Takashi; Miura, Katsuyuki; Fujiyoshi, Akira; Kadota, Aya; Miyagawa, Naoko; Satoh, Atsushi; Zaid, Maryam; Yamamoto, Takashi; Horie, Minoru; Ueshima, Hirotsugu

    2018-06-01

    Calcific aortic valve disease (CAVD) is the most common valve disease. Although micronutrients are known to contribute to cardiovascular disease, the relationship with CAVD remains poorly evaluated. We examined the association of serum levels of magnesium, phosphorus, and calcium with prevalence, incidence, and progression of aortic valve calcification (AVC). We conducted a prospective study in a population-based sample of Japanese men aged 40-79 years without known cardiovascular disease and chronic kidney disease at baseline, and quantified AVC from serial computed tomographic images with the Agatston method. Of 938 participants at baseline (mean age, 63.7 ± 9.9 years), AVC prevalence was observed in 173 (18.4%). Of 596 participants without baseline AVC at follow-up (median duration, 5.1 years), AVC incidence was observed in 138 (23.2%). After adjustment for demographics, behaviors and cardiovascular risk factors, relative risks (95% confidence intervals) in the highest versus lowest categories of serum magnesium, phosphorus, and calcium were 0.62 (0.44-0.86), 1.45 (1.02-2.04), and 1.43 (0.95-2.15), respectively, for AVC prevalence and 0.62 (0.42-0.92), 1.93 (1.28-2.91), and 1.09 (0.77-1.55), respectively, for AVC incidence. Their linear trends of serum magnesium and phosphorus were also all statistically significant. Of 131 participants with baseline AVC, there was no association of any serum micronutrients with AVC progression. Serum magnesium was inversely associated, while serum phosphorus was positively associated with AVC prevalence and incidence, suggesting that these serum micronutrients may be potential candidates for risk prediction or prevention of CAVD, and warranting further studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Prevalence and Prediction of Obstructive Coronary Artery Disease in Patients Undergoing Primary Heart Valve Surgery.

    PubMed

    Cazelli, José Guilherme; Camargo, Gabriel Cordeiro; Kruczan, Dany David; Weksler, Clara; Felipe, Alexandre Rouge; Gottlieb, Ilan

    2017-10-01

    The prevalence of coronary artery disease (CAD) in valvular patients is similar to that of the general population, with the usual association with traditional risk factors. Nevertheless, the search for obstructive CAD is more aggressive in the preoperative period of patients with valvular heart disease, resulting in the indication of invasive coronary angiography (ICA) to almost all adult patients, because it is believed that coronary artery bypass surgery should be associated with valve replacement. To evaluate the prevalence of obstructive CAD and factors associated with it in adult candidates for primary heart valve surgery between 2001 and 2014 at the National Institute of Cardiology (INC) and, thus, derive and validate a predictive obstructive CAD score. Cross-sectional study evaluating 2898 patients with indication for heart surgery of any etiology. Of those, 712 patients, who had valvular heart disease and underwent ICA in the 12 months prior to surgery, were included. The P value < 0.05 was adopted as statistical significance. The prevalence of obstructive CAD was 20%. A predictive model of obstructive CAD was created from multivariate logistic regression, using the variables age, chest pain, family history of CAD, systemic arterial hypertension, diabetes mellitus, dyslipidemia, smoking, and male gender. The model showed excellent correlation and calibration (R² = 0.98), as well as excellent accuracy (ROC of 0.848; 95%CI: 0.817-0.879) and validation (ROC of 0.877; 95%CI: 0.830 - 0.923) in different valve populations. Obstructive CAD can be estimated from clinical data of adult candidates for valve repair surgery, using a simple, accurate and validated score, easy to apply in clinical practice, which may contribute to changes in the preoperative strategy of acquired heart valve surgery in patients with a lower probability of obstructive disease.

  2. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    PubMed Central

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated

  3. Value of Robotically Assisted Surgery for Mitral Valve Disease

    PubMed Central

    Mihaljevic, Tomislav; Koprivanac, Marijan; Kelava, Marta; Goodman, Avi; Jarrett, Craig; Williams, Sarah J.; Gillinov, A. Marc; Bajwa, Gurjyot; Mick, Stephanie L.; Bonatti, Johannes; Blackstone, Eugene H.

    2014-01-01

    Importance The value of robotically assisted surgery for mitral valve disease is questioned because the high cost of care associated with robotic technology may outweigh its clinical benefits. Objective To investigate conditions under which benefits of robotic surgery mitigate high technology costs. Design Clinical cohort study comparing costs of robotic vs. three contemporaneous conventional surgical approaches for degenerative mitral disease. Surgery was performed from 2006–2011, and comparisons were based on intent-to-treat, with propensity-matching used to reduce selection bias. Setting Large multi-specialty academic medical center. Participants 1,290 patients aged 57±11 years, 27% women, underwent mitral repair for regurgitation from posterior leaflet prolapse. Robotic surgery was used in 473, complete sternotomy in 227, partial sternotomy in 349, and anterolateral thoracotomy in 241. Three propensity-matched groups were formed based on demographics, symptoms, cardiac and noncardiac comorbidities, valve pathophysiology, and echocardiographic measurements: robotic vs. sternotomy (n=198 pairs) vs. partial sternotomy (n=293 pairs) vs. thoracotomy (n=224 pairs). Interventions Mitral valve repair. Main Outcome Measures Cost of care, expressed as robotic capital investment, maintenance, and direct technical hospital cost, and benefit of care, based on differences in recovery time. Results Median cost of care for robotically assisted surgery exceeded the cost of alternative approaches by 27% (−5%, 68%), 32% (−6%, 70%), and 21% (−2%, 54%) (median [15th, 85th percentiles]) for complete sternotomy, partial sternotomy, and anterolateral thoracotomy, respectively. Higher operative costs were partially offset by lower postoperative costs and earlier return to work: median 35 days for robotic surgery, 49 for complete sternotomy, 56 for partial sternotomy, and 42 for anterolateral thoracotomy. Resulting net differences in cost of robotic surgery vs. the three

  4. Prosthetic Aortic Valves: Challenges and Solutions

    PubMed Central

    Musumeci, Lucia; Jacques, Nicolas; Hego, Alexandre; Nchimi, Alain; Lancellotti, Patrizio; Oury, Cécile

    2018-01-01

    Aortic Valve Disease (AVD) is the most common Valvular Heart Disease (VHD), affecting millions of people worldwide. Severe AVD is treated in most cases with prosthetic aortic valve replacement, which involves the substitution of the native aortic valve with a prosthetic one. In this review we will discuss the different types of prosthetic aortic valves available for implantation and the challenges faced by patients, medical doctors, researchers and manufacturers, as well as the approaches that are taken to overcome them. PMID:29868612

  5. Does concomitant tricuspid annuloplasty increase perioperative mortality and morbidity when correcting left-sided valve disease?

    PubMed

    Zhu, Tie-Yuan; Wang, Jian-Gang; Meng, Xu

    2015-01-01

    A best evidence topic in adult valvular surgery was written according to a structured protocol. The question addressed was 'Does concomitant tricuspid annuloplasty increase the perioperative mortality and morbidity when correcting left-sided valve disease?' A total of 561 papers were found using the reported search, of which 12 presented the best evidence to answer the clinical question. The authors, country, journal, date of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Among these 12 papers, there were nine retrospective studies, two cohort studies and one randomized controlled trial (RCT). Overall, additional tricuspid valve (TV) repair takes more time during operations, particularly with a ring annuloplasty method. The mean aortic cross-clamping times were 57-83 min without associated tricuspid repair and 62-100 min with, and cardiopulmonary bypass times without and with repair were 82-124 and 90-174 min, respectively. A study of 624 patients who had undergone isolated mitral valve (MV) surgery and MV surgery plus TV repair showed more female and atrial fibrillation patients in the tricuspid valve plasty (TVP) group, but no increase in the 30-day mortality was found. One RCT, presenting similar patient baseline characteristics, also found no difference in the hospital mortality rates between the TVP group and the non-TVP group. Another 10 studies also demonstrated no statistically significant differences in perioperative mortality. In a cohort study of 311 patients undergoing MV repair with or without tricuspid annuloplasty, postoperative complications, such as bleeding, stroke, pacemaker, haemofiltration and myocardial infarction, all showed no statistically significant differences in the two groups. One study retrospectively analysed a large number of patients undergoing either isolated left-sided valve surgery or a concomitant TV repair, and there were no statistically significant differences

  6. Long-Term Results of Mitral Valve Repair

    PubMed Central

    da Costa, Francisco Diniz Affonso; Colatusso, Daniele de Fátima Fornazari; Martin, Gustavo Luis do Santos; Parra, Kallyne Carolina Silva; Botta, Mariana Cozer; Balbi Filho, Eduardo Mendel; Veloso, Myrian; Miotto, Gabriela; Ferreira, Andreia Dumsch de Aragon; Colatusso, Claudinei

    2018-01-01

    Introduction Current guidelines state that patients with severe mitral regurgitation should be treated in reference centers with a high reparability rate, low mortality rate, and durable results. Objective To analyze our global experience with the treatment of organic mitral regurgitation from various etiologies operated in a single center. Methods We evaluated all surgically treated patients with organic mitral regurgitation from 2004-2017. Patients were evaluated clinically and by echocardiography every year. We determined early and late survival rates, valve related events and freedom from recurrent mitral regurgitation and tricuspid regurgitation. Valve failure was defined as any mitral regurgitation ≥ moderate degree or the need for reoperation for any reason. Results Out of 133 patients with organic mitral regurgitation, 125 (93.9%) were submitted to valve repair. Mean age was 57±15 years and 52 patients were males. The most common etiologies were degenerative disease (73 patients) and rheumatic disease (34 patients). Early mortality was 2.4% and late survival was 84.3% at 10 years, which are similar to the age- and gender-matched general population. Only two patients developed severe mitral regurgitation, and both were reoperated (95.6% at 10 years). Freedom from mitral valve failure was 84.5% at 10 years, with no difference between degenerative and rheumatic valves. Overall, late ≥ moderate tricuspid regurgitation was present in 34% of the patients, being more common in the rheumatic ones. The use of tricuspid annuloplasty abolished this complication. Conclusion We have demonstrated that mitral regurgitation due to organic mitral valve disease from various etiologies can be surgically treated with a high repair rate, low early mortality and long-term survival that are comparable to the matched general population. Concomitant treatment of atrial fibrillation and tricuspid valve may be important adjuncts to optimize long-term results. PMID:29617498

  7. Manipulation of valve composition to elucidate the role of collagen in aortic valve calcification

    PubMed Central

    2014-01-01

    Background Extracellular matrix (ECM) disarray is found in calcific aortic valvular disease (CAVD), yet much remains to be learned about the role of individual ECM components in valvular interstitial cell (VIC) function and dysfunction. Previous clinical analyses have shown that calcification is associated with decreased collagen content, while previous in vitro work has suggested that the presence of collagen attenuates the responsiveness of VICs to pro-calcific stimuli. The current study uses whole leaflet cultures to examine the contributions of endogenous collagen in regulating the phenotype and calcification of VICs. Methods A “top-down” approach was used to characterize changes in VIC phenotype in response to collagen alterations in the native 3D environment. Collagen-deficient leaflets were created via enzymatic treatment and cultured statically for six days in vitro. After culture, leaflets were harvested for analysis of DNA, proliferation, apoptosis, ECM composition, calcification, and gene/protein expression. Results In general, disruption of collagen was associated with increased expression of disease markers by VICs in whole organ leaflet culture. Compared to intact control leaflets, collagen-deficient leaflets demonstrated increased VIC proliferation and apoptosis, increased expression of disease-related markers such as alpha-smooth muscle actin, alkaline phosphatase, and osteocalcin, and an increase in calcification as evidenced by positive von Kossa staining. Conclusions These results indicate that disruption of the endogenous collagen structure in aortic valves is sufficient to stimulate pathological consequences in valve leaflet cultures, thereby highlighting the importance of collagen and the valve extracellular matrix in general in maintaining homeostasis of the valve phenotype. PMID:24581344

  8. Estimation of aortic valve leaflets from 3D CT images using local shape dictionaries and linear coding

    NASA Astrophysics Data System (ADS)

    Liang, Liang; Martin, Caitlin; Wang, Qian; Sun, Wei; Duncan, James

    2016-03-01

    Aortic valve (AV) disease is a significant cause of morbidity and mortality. The preferred treatment modality for severe AV disease is surgical resection and replacement of the native valve with either a mechanical or tissue prosthetic. In order to develop effective and long-lasting treatment methods, computational analyses, e.g., structural finite element (FE) and computational fluid dynamic simulations, are very effective for studying valve biomechanics. These computational analyses are based on mesh models of the aortic valve, which are usually constructed from 3D CT images though many hours of manual annotation, and therefore an automatic valve shape reconstruction method is desired. In this paper, we present a method for estimating the aortic valve shape from 3D cardiac CT images, which is represented by triangle meshes. We propose a pipeline for aortic valve shape estimation which includes novel algorithms for building local shape dictionaries and for building landmark detectors and curve detectors using local shape dictionaries. The method is evaluated on real patient image dataset using a leave-one-out approach and achieves an average accuracy of 0.69 mm. The work will facilitate automatic patient-specific computational modeling of the aortic valve.

  9. Percutaneous Pulmonary Valve Placement

    PubMed Central

    Prieto, Lourdes R.

    2015-01-01

    Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629

  10. Calcium Signaling Pathway Genes RUNX2 and CACNA1C Are Associated With Calcific Aortic Valve Disease

    PubMed Central

    Guauque-Olarte, Sandra; Messika-Zeitoun, David; Droit, Arnaud; Lamontagne, Maxime; Tremblay-Marchand, Joël; Lavoie-Charland, Emilie; Gaudreault, Nathalie; Arsenault, Benoit J.; Dubé, Marie-Pierre; Tardif, Jean-Claude; Body, Simon C.; Seidman, Jonathan G.; Boileau, Catherine; Mathieu, Patrick; Pibarot, Philippe; Bossé, Yohan

    2016-01-01

    Background Calcific aortic valve stenosis (AS) is a life-threatening disease with no medical therapy. The genetic architecture of AS remains elusive. This study combines genome-wide association studies, gene expression, and expression quantitative trait loci mapping in human valve tissues to identify susceptibility genes of AS. Methods and Results A meta-analysis was performed combining the results of 2 genome-wide association studies in 474 and 486 cases from Quebec City (Canada) and Paris (France), respectively. Corresponding controls consisted of 2988 and 1864 individuals with European ancestry from the database of genotypes and phenotypes. mRNA expression levels were evaluated in 9 calcified and 8 normal aortic valves by RNA sequencing. The results were integrated with valve expression quantitative trait loci data obtained from 22 AS patients. Twenty-five single-nucleotide polymorphisms had P<5×10−6 in the genome-wide association studies meta-analysis. The calcium signaling pathway was the top gene set enriched for genes mapped to moderately AS-associated single-nucleotide polymorphisms. Genes in this pathway were found differentially expressed in valves with and without AS. Two single-nucleotide polymorphisms located in RUNX2 (runt-related transcription factor 2), encoding an osteogenic transcription factor, demonstrated some association with AS (genome-wide association studies P=5.33×10−5). The mRNA expression levels of RUNX2 were upregulated in calcified valves and associated with eQTL-SNPs. CACNA1C encoding a subunit of a voltage-dependent calcium channel was upregulated in calcified valves. The eQTL-SNP with the most significant association with AS located in CACNA1C was associated with higher expression of the gene. Conclusions This integrative genomic study confirmed the role of RUNX2 as a potential driver of AS and identified a new AS susceptibility gene, CACNA1C, belonging to the calcium signaling pathway. PMID:26553695

  11. Interleukin-37 suppresses the osteogenic responses of human aortic valve interstitial cells in vitro and alleviates valve lesions in mice.

    PubMed

    Zeng, Qingchun; Song, Rui; Fullerton, David A; Ao, Lihua; Zhai, Yufeng; Li, Suzhao; Ballak, Dov B; Cleveland, Joseph C; Reece, T Brett; McKinsey, Timothy A; Xu, Dingli; Dinarello, Charles A; Meng, Xianzhong

    2017-02-14

    Calcific aortic valve disease is a chronic inflammatory process, and aortic valve interstitial cells (AVICs) from diseased aortic valves express greater levels of osteogenic factors in response to proinflammatory stimulation. Here, we report that lower cellular levels of IL-37 in AVICs of diseased human aortic valves likely account for augmented expression of bone morphogenetic protein-2 (BMP-2) and alkaline phosphatase (ALP) following stimulation of Toll-like receptor (TLR) 2 or 4. Treatment of diseased AVICs with recombinant human IL-37 suppresses the levels of BMP-2 and ALP as well as calcium deposit formation. In mice, aortic valve thickening is observed when exposed to a TLR4 agonist or a high fat diet for a prolonged period; however, mice expressing human IL-37 exhibit significantly lower BMP-2 levels and less aortic valve thickening when subjected to the same regimens. A high fat diet in mice results in oxidized low-density lipoprotein (oxLDL) deposition in aortic valve leaflets. Moreover, the osteogenic responses in human AVICs induced by oxLDL are suppressed by recombinant IL-37. Mechanistically, reduced osteogenic responses to oxLDL in human AVICs are associated with the ability of IL-37 to inhibit NF-κB and ERK1/2. These findings suggest that augmented expression of osteogenic factors in AVICs of diseased aortic valves from humans is at least partly due to a relative IL-37 deficiency. Because recombinant IL-37 suppresses the osteogenic responses in human AVICs and alleviates aortic valve lesions in mice exposed to high fat diet or a proinflammatory stimulus, IL-37 has therapeutic potential for progressive calcific aortic valve disease.

  12. Interleukin-37 suppresses the osteogenic responses of human aortic valve interstitial cells in vitro and alleviates valve lesions in mice

    PubMed Central

    Zeng, Qingchun; Song, Rui; Fullerton, David A.; Ao, Lihua; Zhai, Yufeng; Li, Suzhao; Ballak, Dov B.; Cleveland, Joseph C.; Reece, T. Brett; McKinsey, Timothy A.; Xu, Dingli; Dinarello, Charles A.; Meng, Xianzhong

    2017-01-01

    Calcific aortic valve disease is a chronic inflammatory process, and aortic valve interstitial cells (AVICs) from diseased aortic valves express greater levels of osteogenic factors in response to proinflammatory stimulation. Here, we report that lower cellular levels of IL-37 in AVICs of diseased human aortic valves likely account for augmented expression of bone morphogenetic protein-2 (BMP-2) and alkaline phosphatase (ALP) following stimulation of Toll-like receptor (TLR) 2 or 4. Treatment of diseased AVICs with recombinant human IL-37 suppresses the levels of BMP-2 and ALP as well as calcium deposit formation. In mice, aortic valve thickening is observed when exposed to a TLR4 agonist or a high fat diet for a prolonged period; however, mice expressing human IL-37 exhibit significantly lower BMP-2 levels and less aortic valve thickening when subjected to the same regimens. A high fat diet in mice results in oxidized low-density lipoprotein (oxLDL) deposition in aortic valve leaflets. Moreover, the osteogenic responses in human AVICs induced by oxLDL are suppressed by recombinant IL-37. Mechanistically, reduced osteogenic responses to oxLDL in human AVICs are associated with the ability of IL-37 to inhibit NF-κB and ERK1/2. These findings suggest that augmented expression of osteogenic factors in AVICs of diseased aortic valves from humans is at least partly due to a relative IL-37 deficiency. Because recombinant IL-37 suppresses the osteogenic responses in human AVICs and alleviates aortic valve lesions in mice exposed to high fat diet or a proinflammatory stimulus, IL-37 has therapeutic potential for progressive calcific aortic valve disease. PMID:28137840

  13. Experimental assessment of valve performance in healthy and diseased right ventricular outflow tracts using magnetic resonance velocimetry

    NASA Astrophysics Data System (ADS)

    Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison

    2017-11-01

    Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.

  14. TGF-β mediates early angiogenesis and latent fibrosis in an Emilin1-deficient mouse model of aortic valve disease

    PubMed Central

    Munjal, Charu; Opoka, Amy M.; Osinska, Hanna; James, Jeanne F.; Bressan, Giorgio M.; Hinton, Robert B.

    2014-01-01

    Aortic valve disease (AVD) is characterized by elastic fiber fragmentation (EFF), fibrosis and aberrant angiogenesis. Emilin1 is an elastin-binding glycoprotein that regulates elastogenesis and inhibits TGF-β signaling, but the role of Emilin1 in valve tissue is unknown. We tested the hypothesis that Emilin1 deficiency results in AVD, mediated by non-canonical (MAPK/phosphorylated Erk1 and Erk2) TGF-β dysregulation. Using histology, immunohistochemistry, electron microscopy, quantitative gene expression analysis, immunoblotting and echocardiography, we examined the effects of Emilin1 deficiency (Emilin1−/−) in mouse aortic valve tissue. Emilin1 deficiency results in early postnatal cell-matrix defects in aortic valve tissue, including EFF, that progress to latent AVD and premature death. The Emilin1−/− aortic valve displays early aberrant provisional angiogenesis and late neovascularization. In addition, Emilin1−/− aortic valves are characterized by early valve interstitial cell activation and proliferation and late myofibroblast-like cell activation and fibrosis. Interestingly, canonical TGF-β signaling (phosphorylated Smad2 and Smad3) is upregulated constitutively from birth to senescence, whereas non-canonical TGF-β signaling (phosphorylated Erk1 and Erk2) progressively increases over time. Emilin1 deficiency recapitulates human fibrotic AVD, and advanced disease is mediated by non-canonical (MAPK/phosphorylated Erk1 and Erk2) TGF-β activation. The early manifestation of EFF and aberrant angiogenesis suggests that these processes are crucial intermediate factors involved in disease progression and therefore might provide new therapeutic targets for human AVD. PMID:25056700

  15. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    PubMed

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p < 0.0001) during a median follow-up period of 24.0 and 35.5 months, respectively (p = 0.03). For patients with BJV valves, the incidence of IE was not different between surgical and catheter-based valve implantation (p = 0.83). There was a higher incidence of endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Platelet dysfunction detected at high shear in patients with heart valve disease.

    PubMed

    Francis, J L

    2000-05-01

    Whether patients with valvular heart disease have a defect of platelet function has been unclear. Despite evidence that these individuals have an abnormality detectable only under conditions of high shear stress, no methods have been widely available to adequately assess platelet function under such conditions. The Platelet Function Analyzer (PFA)-100 measures platelet function in a high shear environment and is well suited to the detection of platelet dysfunction in the clinical laboratory. The instrument records the time for platelets to occlude a membrane coated with collagen and either epinephrine (CEPI) or ADP (CADP). We studied the PFA-100 in 398 patients before open heart surgery; 308 for coronary artery bypass grafting (CABG) and 90 for aortic or mitral valve replacement (VR). Patients were classified as normal (CEPI < or = 153 s); 'aspirin effect' (CEPI > 153 s but CADP < or = 109 s) or abnormal (CEPI > 153 s and CADP > 109 s). In the CABG group, 41.2% were classified as normal, 43.2% as 'aspirin effect' and 15.6% as abnormal. In contrast, in patients undergoing VR, these values were 6.7, 11.1 and 82.4%, respectively. Patients with valvular disease had significantly longer closure times for both CEPI and CADP tests (P < 0.001). In addition, the valvular disease group had a significantly higher proportion of patients with markedly prolonged (> 150 s) closure times in the CADP cartridge (43.3 vs. 3.6%, respectively). Only one (0.3%) patient in the CABG group had non-closure (> 300 s) in the CADP test compared to seven (7.8%) in the valvular disease group. Three of six patients in the latter group bled excessively during surgery. We conclude that abnormal CADP closure is much more frequent among patients with aortic or mitral valve disease compared to those with coronary artery disease. This may reflect pre-existing high-shear damage to platelets that renders them refractory to subsequent shear activation and aggregation in the PFA-100 system. Further studies

  17. Pars plana Ahmed valve and vitrectomy in patients with glaucoma associated with posterior segment disease.

    PubMed

    Wallsh, Josh O; Gallemore, Ron P; Taban, Mehran; Hu, Charles; Sharareh, Behnam

    2013-01-01

    To assess the safety and efficacy of a modified technique for pars plana placement of the Ahmed valve in combination with pars plana vitrectomy in the treatment of glaucoma associated with posterior segment disease. Thirty-nine eyes with glaucoma associated with posterior segment disease underwent pars plana vitrectomy combined with Ahmed valve placement. All valves were placed in the pars plana using a modified technique, without the pars plana clip, and using a scleral patch graft. The 24 eyes diagnosed with neovascular glaucoma had an improvement in intraocular pressure from 37.6 mmHg to 13.8 mmHg and best-corrected visual acuity from 2.13 logarithm of minimum angle of resolution to 1.40 logarithm of minimum angle of resolution. Fifteen eyes diagnosed with steroid-induced glaucoma had an improvement in intraocular pressure from 27.9 mmHg to 14.1 mmHg and best-corrected visual acuity from 1.38 logarithm of minimum angle of resolution to 1.13 logarithm of minimum angle of resolution. Complications included four cases of cystic bleb formation and one case of choroidal detachment and explantation for hypotony. Ahmed valve placement through the pars plana during vitrectomy is an effective option for managing complex cases of glaucoma without the use of the pars plana clip.

  18. Outcomes of ring versus suture annuloplasty for tricuspid valve repair in patients undergoing mitral valve surgery.

    PubMed

    Shinn, Sung Ho; Dayan, Victor; Schaff, Hartzell V; Dearani, Joseph A; Joyce, Lyle D; Lahr, Brian; Greason, Kevin L; Stulak, John M; Daly, Richard C

    2016-08-01

    There is controversy regarding the comparative effectiveness of methods of tricuspid valve (TV) repair-prosthetic ring versus suture annuloplasty-in patients undergoing operation for primary mitral valve (MV) disease. In this study, we analyzed factors associated with patient survival and recurrent tricuspid regurgitation (TR) following TV repair and focused on results stratified by method of tricuspid valve repair. We reviewed patients who underwent TV repair with suture (De Vega) or flexible ring annuloplasties at the time of MV surgery from 1995 to 2010. Patients with prior cardiac or concomitant aortic valve operations were excluded. Propensity matching was performed to account for potential differences in baseline characteristics between the groups. Primary outcomes were long-term mortality and postoperative TR grade. In the overall study, there were 415 patients with median age 72 years (range, 63-78 years), from which 148 matched pairs were identified by propensity score analysis. In the overall cohort, patients in the ring annuloplasty group more often had preoperative transvenous pacemakers (P = .05), lower ejection fractions (P = .028), and more recent years of operation (P < .001). For patients who had De Vega suture annuloplasty, long-term mortality was not different from that of patients who had ring annuloplasty (hazard ratio, 0.93; 95% confidence interval, 0.67-1.30). Older age, preoperative diabetes, and preoperative right ventricular dysfunction were predictors for long-term mortality. Durability of the annuloplasty methods was similar with no significant difference in trend of recurrent TR grades over follow-up (P = .807). Etiology of mitral regurgitation was not associated with recurrent TR during follow-up (P = .857). Late survival and TV durability following concomitant TV repair during MV surgery did not differ with respect to TV repair technique. In this series of patients with repaired tricuspid valves, etiology of MV disease did

  19. Intraoperative assessment of mitral valve area after mitral valve repair: comparison of different methods.

    PubMed

    Maslow, Andrew; Gemignani, Anthony; Singh, Arun; Mahmood, Feroze; Poppas, Athena

    2011-04-01

    In the present study, 3 different methods to measure the mitral valve area (MVA) after mitral valve repair (MVRep) were studied. Data obtained immediately after repair were compared with postoperative data. The objective was to determine the feasibility and correlation between intraoperative and postoperative MVA data. A prospective study. A tertiary care medical center. Twenty-five elective adult surgical patients scheduled for MVRep. Echocardiographic data included MVAs obtained using the pressure half-time (PHT), 2-dimensional planimetry (2D-PLAN), and the continuity equation (CE). These data were obtained immediately after cardiopulmonary bypass and were compared with data obtained before hospital discharge (transthoracic echocardiogram 1) and 6 to 12 months after surgery (transthoracic echocardiogram 2). Intraoperative care was guided by hemodynamic goals designed to optimize cardiac function. The data show good agreement and correlation between MVA obtained with PHT and 2D-PLAN within and between each time period. MVA data obtained with the CE in the postoperative period were lower than and did not correlate or agree as well with other MVA data. The MVA recorded immediately after valve repair, using PHT, correlated and agreed with MVA data obtained in the postoperative period. These results contrast with previously published data and could highlight the impact of hemodynamic function during the assessment of MVA. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Optimal Control of the Valve Based on Traveling Wave Method in the Water Hammer Process

    NASA Astrophysics Data System (ADS)

    Cao, H. Z.; Wang, F.; Feng, J. L.; Tan, H. P.

    2011-09-01

    Valve regulation is an effective method for process control during the water hammer. The principle of d'Alembert traveling wave theory was used in this paper to construct the exact analytical solution of the water hammer, and the optimal speed law of the valve that can reduce the water hammer pressure in the maximum extent was obtained. Combining this law with the valve characteristic curve, the principle corresponding to the valve opening changing with time was obtained, which can be used to guide the process of valve closing and to reduce the water hammer pressure in the maximum extent.

  1. The anatomy and physiology of the terminal thoracic duct and ostial valve in health and disease: potential implications for intervention.

    PubMed

    Ratnayake, Chathura Bathiya Bandara; Escott, Alistair Brian James; Phillips, Anthony Ronald John; Windsor, John Albert

    2018-07-01

    The thoracic duct (TD) transports lymph drained from the body to the venous system in the neck via the lymphovenous junction. There has been increased interest in the TD lymph (including gut lymph) because of its putative role in the promotion of systemic inflammation and organ dysfunction during acute and critical illness. Minimally invasive TD cannulation has recently been described as a potential method to access TD lymph for investigation. However, marked anatomical variability exists in the terminal segment and the physiology regarding the ostial valve and terminal TD is poorly understood. A systematic review was conducted using three databases from 1909 until May 2017. Human and animal studies were included and data from surgical, radiological and cadaveric studies were retrieved. Sixty-three articles from the last 108 years were included in the analysis. The terminal TD exists as a single duct in its terminal course in 72% of cases and 13% have multiple terminations: double (8.5%), triple (1.8%) and quadruple (2.2%). The ostial valve functions to regulate flow in relation to the respiratory cycle. The patency of this valve found at the lymphovenous junction opening, is determined by venous wall tension. During inspiration, central venous pressure (CVP) falls and the valve cusps collapse to allow antegrade flow of lymph into the vein. During early expiration when CVP and venous wall tension rises, the ostial valve leaflets cover the opening of the lymphovenous junction preventing antegrade lymph flow. During chronic disease states associated with an elevated mean CVP (e.g. in heart failure or cirrhosis), there is a limitation of flow across the lymphovenous junction. Although lymph production is increased in both heart failure and cirrhosis, TD lymph outflow across the lymphovenous junction is unable to compensate for this increase. In conclusion the terminal TD shows marked anatomical variability and TD lymph flow is controlled at the ostial valve, which

  2. In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart Valve

    PubMed Central

    Claiborne, Thomas E.; Sheriff, Jawaad; Kuetting, Maximilian; Steinseifer, Ulrich; Slepian, Marvin J.; Bluestein, Danny

    2013-01-01

    Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the

  3. Fluid-structure interaction analysis of the flow through a stenotic aortic valve

    NASA Astrophysics Data System (ADS)

    Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes

    2009-11-01

    In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.

  4. Mid-term results of mitral valve repair using flexible bands versus complete rings in patients with degenerative mitral valve disease: a prospective, randomized study.

    PubMed

    Bogachev-Prokophiev, Alexandr V; Afanasyev, Alexandr V; Zheleznev, Sergei I; Nazarov, Vladimir M; Sharifulin, Ravil M; Karaskov, Alexandr M

    2017-12-13

    We aimed to compare the outcomes of mitral valve repair with flexible band (FB) versus complete semirigid ring (SR) in degenerative mitral valve disease patients. From September 2011 to 2014, 171 patients were randomized and underwent successful mitral valve repair using a SR (n = 85) or FB (n = 86). There were no significant between-group differences at baseline. There were no early mortalities. The mean follow up was 24.7 months. The 2-year survival was 96.0 ± 2.3% (95% confidence interval [CI], 88.6-98.7%) and 94.3 ± 2.8% (95% CI, 85.5-97.9%) in the SR and FB groups, respectively (p = 0.899). The left ventricle remodeling was similar between the groups. Higher transmitral peak (8.5 [3.9-17] vs. 6 [2.1-18] mmHg, p < 0.001), mean pressure gradients (3.7 [1.3-8] vs. 2.8 [0.6-6.8] mmHg, p = 0.001), and systolic pulmonary artery pressure (34.5 [20-68] vs. 29.5 [8-48] mmHg, p < 0.001) was observed in the SR group. The 2-year freedom from recurrence of significant mitral regurgitation was significantly higher in the FB group than the SR group (p = 0.002). Residual mitral regurgitation was an independent prognostic factor of recurrence of mitral regurgitation. The 3-year freedom from reoperation was significantly higher in the FB group than the SR group (p = 0.044). Patients with degenerative mitral valve disease may benefit from valve repair with FBs. Residual mitral regurgitation before discharge is an independent risk factor of late insufficiency recurrence. ClinicalTrials.gov NCT03278574 , retrospectively registered on 06.09.2017.

  5. Contemporary experience with surgical treatment of aortic valve disease in children.

    PubMed

    Khan, Muhammad S; Samayoa, Andres X; Chen, Diane W; Petit, Christopher J; Fraser, Charles D

    2013-09-01

    Surgical treatment of aortic valve (AoV) disease in childhood involves complex decisions particularly in very small patients. There is no consensus regarding the optimum surgical option. The objective of this review was to analyze a contemporary experience of AoV surgery in a large children's hospital. A retrospective review of children (aged ≤ 18 years) undergoing AoV repair or replacement from June 1995 to December 2011 was carried out. A total of 285 AoV operations (97 repairs, 188 replacements) were performed on 241 patients. Hospital survival for repair was 98% and for replacements was 97%. At follow-up of repairs, there were 16 (17%) reoperations and 3 (3%) late deaths. Follow-up of AoV replacements demonstrated 31 (16%) reoperations (homograft 27, autograft 3, mechanical 1) and 8 (4%) late deaths (homograft 5, autograft 2, mechanical 1). Freedom from reintervention or death (FRD) was found to be lower in repairs for infants (P = .048) and truncal valves (P < .05). For AoV replacements, infants and patients who had concomitant CHD or homografts (P < .0001) had lower FRD. Cox regression analysis for AoV replacements identified infants and homograft root replacements at a higher risk for death/reoperation. AoV repairs and replacements were generally found to be associated with low death and reoperation rates at long-term follow-up. Infants had a lower freedom from reintervention or death after either an AoV repair or replacement, although truncal valve repairs and AoV replacement in patients with concomitant CHD were associated with lower valve survival. Among the valve options, homograft root replacement had a higher risk of death/reoperation and lowest freedom from reintervention or death. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Triple valve surgery: a 25-year experience.

    PubMed

    Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen

    2004-09-01

    Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become

  7. The Effect of Neonatal Gene Therapy with a Gamma Retroviral Vector on Cardiac Valve Disease in Mucopolysaccharidosis VII Dogs after a Decade

    PubMed Central

    Bigg, Paul W.; Sleeper, Meg M.; O’Donnell, Patricia A.; Liu, Yuli; Wu, Susan; Casal, Margret L.; Haskins, Mark E.; Ponder, Katherine P.

    2013-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient activity of the lysosomal enzyme β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs). This study determined the long-term effect of neonatal intravenous injection of a gamma retroviral vector (RV) on cardiac valve disease in MPS VII dogs. Transduced hepatocytes secreted GUSB into blood for up to 11 years at levels similar to or greater than those achieved with enzyme replacement therapy (ERT). Valve regurgitation and thickening were scored from 0 (normal) to +4 (severely abnormal). At 1 year, untreated MPS VII dogs had mitral regurgitation, mitral valve thickening, aortic regurgitation, and aortic valve thickening scores of 2.3±0.7, 2.3±0.6, 1.8±0.5, and 1.6±0.7, respectively, which were higher than the values of 0.6±0.1, 0.1±0.4, 0.3±0.8, and 0.1±0.4, respectively, in treated MPS VII dogs. Treated MPS VII dogs maintained low aortic regurgitation and aortic valve thickening scores for their lifetime. Although mitral regurgitation and mitral valve thickening scores increased to 2.0 at ≥8 years of age in the treated MPS VII dogs, older normal dogs from the colony had similar scores, making it difficult to assess mitral valve disease. Older treated dogs had calcification within the mitral and aortic valve annulus, while GUSB staining demonstrated enzyme activity within the mitral valve. We conclude that neonatal RV-mediated gene therapy reduced cardiac valve disease in MPS VII dogs for up to 11 years, and propose that neonatal initiation of ERT should have a similar effect. PMID:23860311

  8. Mitral valve replacement with the Hancock stabilized glutaraldehyde valve. Clinical and laboratory evaluation.

    PubMed

    Buch, W S; Pipkin, R D; Hancock, W D; Fogarty, T J

    1975-11-01

    From March 1971 through April 1975, one hundred twenty patients underwent mitral valve replacement with a Hancock "stabilized glutaraldehyde process" porcine aortic xenograft. A simultaneous canine experimental series was also carried out. In the clinical series, the early mortality was 8.3%. Actuarial analyses of all patients predicts survival at two years of 81.0% and at four years of 70.0%. The predicted survival for patients without coronary disease or prior prosthetic valve replacement is 87.5% at two years and 77.5% at four years. There were four thromboembolic episodes, a rate of 2.4% per patient-year. None were fatal. No valve failure were noted. Histologic examination and shrink temperature analysis of recovered valves show excellent tissue preservation at 40 months. The data indicate that the Hancock valve is durable, enjoys a low incidence of thromboembolism, and may be the valve of choice for mitral valve replacement.

  9. Non-functional tricuspid valve disease.

    PubMed

    Adler, Dale S

    2017-05-01

    Only 75% of severe tricuspid regurgitation is classified as functional, or related primarily to pulmonary hypertension, right ventricular dysfunction, or a combination of both. Non-functional tricuspid regurgitation occurs when there is damage to the tricuspid leaflets, chordae, papillary muscles, or annulus, independent of right ventricular dysfunction or pulmonary hypertension. The entities that cause non-functional tricuspid regurgitation include rheumatic and myxomatous disease, acquired and genetic connective tissue disorders, endocarditis, sarcoid, pacing, RV biopsy, blunt trauma, radiation, carcinoid, ergot alkaloids, dopamine agonists, fenfluramine, cardiac tumors, atrial fibrillation, and congenital malformations. Over time, severe tricuspid regurgitation that is initially non-functional, can blend into functional tricuspid regurgitation, related to progressive right ventricular dysfunction. Symptoms and signs, including a falling right ventricular ejection fraction, cardiac cirrhosis, ascites, esophageal varices, and anasarca, may occur insidiously and late, but are associated with substantial morbidity and mortality. Attempted valve repair or replacement at late stages carries a high mortality. Crucial to following patients with severe non-functional tricuspid regurgitation is attention to echo quantification of the tricuspid regurgitation and right ventricular function, patient symptoms, and the physical examination.

  10. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    PubMed

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe

  11. The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement

    PubMed Central

    McElhinney, Doff B; Hennesen, Jill T

    2013-01-01

    The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411

  12. Prior oral conditions in patients undergoing heart valve surgery.

    PubMed

    Silvestre, Francisco-Javier; Gil-Raga, Irene; Martinez-Herrera, Mayte; Lauritano, Dorina; Silvestre-Rangil, Javier

    2017-11-01

    Patients scheduled for heart valve surgery should be free of any oral infectious disorders that might pose a risk in the postoperative period. Few studies have been made on the dental conditions of such patients prior to surgery. The present study describes the most frequent prior oral diseases in this population group. A prospective, observational case-control study was designed involving 60 patients (30 with heart valve disease and 30 controls, with a mean age of 71 years in both groups). A dental exploration was carried out, with calculation of the DMFT (decayed, missing and filled teeth) index and recording of the periodontal parameters (plaque index, gingival bleeding index, periodontal pocket depth, and attachment loss). The oral mucosa was also examined, and panoramic X-rays were used to identify possible intrabony lesions. Significant differences in bacterial plaque index were observed between the two groups ( p <0.05), with higher scores in the patients with valve disease. Probing depth and the presence of moderate pockets were also greater in the patients with valve disease than among the controls ( p <0.01). Sixty percent of the patients with valve disease presented periodontitis. Patients scheduled for heart valve surgery should be examined for possible active periodontitis before the operation. Those individuals found to have periodontal disease should receive adequate periodontal treatment before heart surgery. Key words: Valve disease, aortic, mitral, heart surgery, periodontitis.

  13. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall be...

  14. Tricuspid regurgitation and right ventricular function after mitral valve surgery with or without concomitant tricuspid valve procedure.

    PubMed

    Desai, Ravi R; Vargas Abello, Lina Maria; Klein, Allan L; Marwick, Thomas H; Krasuski, Richard A; Ye, Ying; Nowicki, Edward R; Rajeswaran, Jeevanantham; Blackstone, Eugene H; Pettersson, Gösta B

    2013-11-01

    To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+ (100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+ or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant

  15. The effect of neonatal gene therapy with a gamma retroviral vector on cardiac valve disease in mucopolysaccharidosis VII dogs after a decade.

    PubMed

    Bigg, Paul W; Sleeper, Meg M; O'Donnell, Patricia A; Liu, Yuli; Wu, Susan; Casal, Margret L; Haskins, Mark E; Ponder, Katherine P

    2013-11-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient activity of the lysosomal enzyme β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs). This study determined the long-term effect of neonatal intravenous injection of a gamma retroviral vector (RV) on cardiac valve disease in MPS VII dogs. Transduced hepatocytes secreted GUSB into the blood for up to 11 years at levels similar to or greater than those achieved with enzyme replacement therapy (ERT). Valve regurgitation and thickening were scored from 0 (normal) to +4 (severely abnormal). At 1 year, untreated MPS VII dogs had mitral regurgitation, mitral valve thickening, aortic regurgitation, and aortic valve thickening scores of 2.3 ± 0.7, 2.3 ± 0.6, 1.8 ± 0.5, and 1.6 ± 0.7, respectively, which were higher than the values of 0.6 ± 0.1, 0.1 ± 0.4, 0.3 ± 0.8, and 0.1 ± 0.4, respectively, in treated MPS VII dogs. Treated MPS VII dogs maintained low aortic regurgitation and aortic valve thickening scores in their lifetime. Although mitral regurgitation and mitral valve thickening scores increased to 2.0 at ≥ 8 years of age in the treated MPS VII dogs, older normal dogs from the colony had similar scores, making it difficult to assess mitral valve disease. Older treated dogs had calcification within the mitral and the aortic valve annulus, while GUSB staining demonstrated enzyme activity within the mitral valve. We conclude that neonatal RV-mediated gene therapy reduced cardiac valve disease in MPS VII dogs for up to 11 years, and propose that neonatal initiation of ERT should have a similar effect. © 2013.

  16. A Comparative Result of Ventriculoperitoneal Shunt, Focusing Mainly on Gravity-Assisted Valve and Programmable Valve

    PubMed Central

    Lee, Won-Chul; Choe, Il-Seung; Park, Sung-Choon; Ha, Young-Soo; Lee, Kyu Chang

    2010-01-01

    Objective Despite rapid evolution of shunt devices, the complication rates remain high. The most common causes are turning from obstruction, infection, and overdrainage into mainly underdrainage. We investigated the incidence of complications in a consecutive series of hydrocephalic patients. Methods From January 2002 to December 2009, 111 patients underwent ventriculoperitoneal (VP) shunting at our hospital. We documented shunt failures and complications according to valve type, primary disease, and number of revisions. Results Overall shunt survival time was 268 weeks. Mean survival time of gravity-assisted valve (GAV) was 222 weeks versus 286 weeks for other shunts. Survival time of programmable valves (264 weeks) was longer than that of pressure-controlled valves (186 weeks). The most common cause for shunt revision was underdrainage (13 valves). The revision rate due to underdrainage in patients with GAV (7 of 10 patients) was higher than that for other valve types. Of 7 patients requiring revision for GAV underdrainage, 6 patients were bedridden. The overall infection rate was 3.6%, which was lower than reported series. Seven patients demonstrating overdrainage had cranial defects when operations were performed (41%), and overdrainage was improved in 5 patients after cranioplasty. Conclusion Although none of the differences was statistically significant, some of the observations were especially notable. If a candidate for VP shunting is bedridden, GAV may not be indicated because it could lead to underdrainage. Careful procedure and perioperative management can reduce infection rate. Cranioplasty performed prior to VP shunting may be beneficial. PMID:21082054

  17. Transcatheter Mitral Valve Replacement for Native and Failed Bioprosthetic Mitral Valves

    PubMed Central

    Sarkar, Kunal; Reardon, Michael J.; Little, Stephen H.; Barker, Colin M.; Kleiman, Neal S.

    2017-01-01

    Transcatheter mitral valve replacement (TMVR) is a novel approach for treatment of severe mitral regurgitation. A number of TMVR devices are currently undergoing feasibility trials using both transseptal and transapical routes for device delivery. Overall experience worldwide is limited to fewer than 200 cases. At present, the 30-day mortality exceeds 30% and is attributable to both patient- and device-related factors. TMVR has been successfully used to treat patients with degenerative mitral stenosis (DMS) as well as failed mitral bioprosthesis and mitral repair using transcatheter mitral valve-in-valve (TMViV)/valve-in-ring (ViR) repair. These patients are currently treated with devices designed for transcatheter aortic valve replacement. Multicenter registries have been initiated to collect outcomes data on patients currently undergoing TMViV/ViR and TMVR for DMS and have confirmed the feasibility of TMVR in these patients. However, the high periprocedural and 30-day event rates underscore the need for further improvements in device design and multicenter randomized studies to delineate the role of these technologies in patients with mitral valve disease. PMID:29743999

  18. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease.

    PubMed

    Meurs, Kathryn M; Olsen, Lisbeth H; Reimann, Maria J; Keene, Bruce W; Atkins, Clarke E; Adin, Darcy; Aona, Brent; Condit, Julia; DeFrancesco, Teresa; Reina-Doreste, Yamir; Stern, Joshua A; Tou, Sandra; Ward, Jessica; Woodruff, Kathleen

    2018-02-01

    Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated with alterations in ACE activity at different stages of cardiac disease. Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Forty-three dogs were homozygous for the ACE polymorphism; five were heterozygous and 25 were homozygous wild type. The mean age and the median severity of disease were not different for dogs with the polymorphism and dogs with the wild-type sequence. The median baseline ACE activity was significantly lower for the ACE polymorphism (27.0 U/l) than the wild-type sequence dogs (31.0 U/l) (P=0.02). Dogs with more severe disease and the ACE polymorphism had significantly lower levels of ACE activity than dogs with the wild-type sequence (P=0.03). The CKCS appears to have a high prevalence of the ACE variant. Dogs with the ACE variant had lower levels of ACE activity even in more advanced mitral valve disease than dogs without the variant. The clinical significance of this finding and its impact on the need for ACE-I in dogs with the polymorphism and heart disease deserves further study.

  19. Matrix metalloproteinase inhibitor, doxycycline and progression of calcific aortic valve disease in hyperlipidemic mice.

    PubMed

    Jung, Jae-Joon; Razavian, Mahmoud; Kim, Hye-Yeong; Ye, Yunpeng; Golestani, Reza; Toczek, Jakub; Zhang, Jiasheng; Sadeghi, Mehran M

    2016-09-13

    Calcific aortic valve disease (CAVD) is the most common cause of aortic stenosis. Currently, there is no non-invasive medical therapy for CAVD. Matrix metalloproteinases (MMPs) are upregulated in CAVD and play a role in its pathogenesis. Here, we evaluated the effect of doxycycline, a nonselective MMP inhibitor on CAVD progression in the mouse. Apolipoprotein (apo)E(-/-) mice (n = 20) were fed a Western diet (WD) to induce CAVD. After 3 months, half of the animals was treated with doxycycline, while the others continued WD alone. After 6 months, we evaluated the effect of doxycycline on CAVD progression by echocardiography, MMP-targeted micro single photon emission computed tomography (SPECT)/computed tomography (CT), and tissue analysis. Despite therapeutic blood levels, doxycycline had no significant effect on MMP activation, aortic valve leaflet separation or flow velocity. This lack of effect on in vivo images was confirmed on tissue analysis which showed a similar level of aortic valve gelatinase activity, and inflammation between the two groups of animals. In conclusion, doxycycline (100 mg/kg/day) had no effect on CAVD progression in apoE(-/-) mice with early disease. Studies with more potent and specific inhibitors are needed to establish any potential role of MMP inhibition in CAVD development and progression.

  20. Spontaneous retrotransposon insertion into TNF 3'UTR causes heart valve disease and chronic polyarthritis.

    PubMed

    Lacey, Derek; Hickey, Peter; Arhatari, Benedicta D; O'Reilly, Lorraine A; Rohrbeck, Leona; Kiriazis, Helen; Du, Xiao-Jun; Bouillet, Philippe

    2015-08-04

    Rheumatoid arthritis (RA) and ankylosing spondylitis (AS) are chronic inflammatory diseases that together affect 2-3% of the population. RA and AS predominantly involve joints, but heart disease is also a common feature in RA and AS patients. Here we have studied a new spontaneous mutation that causes severe polyarthritis in bone phenotype spontaneous mutation 1 (BPSM1) mice. In addition to joint destruction, mutant mice also develop aortic root aneurism and aorto-mitral valve disease that can be fatal depending on the genetic background. The cause of the disease is the spontaneous insertion of a retrotransposon into the 3' untranslated region (3'UTR) of the tumor necrosis factor (TNF), which triggers its strong overexpression in myeloid cells. We found that several members of a family of RNA-binding, CCCH-containing zinc-finger proteins control TNF expression through its 3'UTR, and we identified a previously unidentified regulatory element in the UTR. The disease in BPSM1 mice is independent of the adaptive immune system and does not appear to involve inflammatory cytokines other than TNF. To our knowledge, this is the first animal model showing both polyarthritis and heart disease as a direct result of TNF deregulation. These results emphasize the therapeutic potential of anti-TNF drugs for the treatment of heart valve disease and identify potential therapeutic targets to control TNF expression and inflammation.

  1. Outcomes following balloon mitral valvuloplasty in pregnant females with mitral stenosis and significant sub valve disease with severe decompensated heart failure.

    PubMed

    Ananthakrishna Pillai, Ajith; Ramasamy, Chandramohan; V, Saranya Gousy; Kottyath, Harichandrakumar

    2018-03-11

    Mitral stenosis may present with decompensated heart failure during pregnancy. Many patients do have advanced sub valve disease and present late with decompensated state. The outcomes of balloon mitral valvuloplasty (BMV) in such advanced sub valve disease with severe heart failure in pregnancy has not been specifically studied till now. A descriptive study looking at the immediate and long-term outcomes of pregnant patients with MS who presented with severe heart failure and sub valve disease who had undergone BMV. Ninety-six patients were studied. The mean gestational age was 23.4 ± 10.9 weeks .Mean SpO2 was 89% at admission,17% were in cardiogenic shock and 33.33 were on mechanical ventilation. The mean Wilkin's score was 9.71 ± 2.1 and sub valve score was 3.3 ± 0.12. BMV was successful in 77 (80.2%) patients and failed in 19. In 5.2% cases, acute severe MR occurred. There were 11 maternal deaths (six in failed and five in success group). A successful obstetric outcome was seen in 71 patients in success (92%) and 11/19 (57%) in failed (P < 0.001). The obstetric outcomes were better in success versus failure group. Anova post hoc analysis showed sustained gradient reductions at 1 and 5 year follow-up (P = 0.03) in success group. BMV offers substantial improvement in clinical outcomes among pregnant patients with MS and heart failure even with severe sub valve disease. The morality rate among failed was high at 31%. The obstetric outcomes were poor after a failed BMV. Outcomes following balloon mitral valvuloplasty in pregnant females with mitral stenosis and significant sub valve disease with severe decompensated heart failure. © 2018, Wiley Periodicals, Inc.

  2. Predictor of left ventricular dysfunction after aortic valve replacement in mixed aortic valve disease.

    PubMed

    Egbe, Alexander C; Warnes, Carole A

    2017-02-01

    The fate of the left ventricle (LV) after aortic valve replacement (AVR) in mixed aortic valve disease (MAVD) is unknown. Patients with moderate-severe MAVD, ejection fraction ≥50%, and no coronary artery disease who underwent AVR were identified. Moderate-severe MAVD was defined as a combination of ≥moderate aortic stenosis and ≥moderate aortic regurgitation. Assessment for LVD was performed at 1 and 5years after AVR. The purpose of the study was to determine prevalence and predictors of early and late left ventricular dysfunction (LVD) defined as ejection fraction <50% at 1 and 5years post-AVR. The severity of LV hypertrophy was assessed using LV mass index (LVMI), while relative wall thickness (RWT) was used to determine the type of hypertrophy. RWT was calculated as (2×posterior wall thickness)/LV end-diastolic dimension (LVEDD). A RWT score ≥0.42 and <0.42 indicates concentric and eccentric hypertrophy respectively. Patients with MAVD (n=179); age 63±8years, males 134 (75%); underwent AVR at Mayo Clinic, 1994-2010. Early LVD occurred in 38(21%). Predictors of early LVD were LVMI/LVEDD >3.1 (HR 1.83, CI 1.59-1.98); RWT >0.46 (HR 2.16, CI 1.21-4.99); and older age (HR 1.62, CI 1.23-3.02). Assessment of LV function was performed in 124 patients at 5-years post-AVR, and late LVD was present in 29(23%). Predictors of late LVD were LVMI/LVEDD >3.1 (HR 1.77, CI 1.24-2.01) and RWT >0.46 (HR 1.65, CI 1.29-2.24). All-cause mortality occurred in 21(12%), and was more common in patients with LVMI/LVEDD >3.1 (P=0.043) and RWT >0.46 (P=0.029). Patients with postoperative LVD showed less regression of LV mass after AVR even after controlling for blood pressure. LVD can occur after AVR even in the setting of normal preoperative LV function and absence of coronary artery disease. Preoperative LV mass was predictive of LVD and should be taken into consideration when determining the timing of AVR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis

    PubMed Central

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-01-01

    Objective: Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. Methods: One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. Results: ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Conclusions: Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival. PMID:24903989

  4. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Programming jammed Codman Hakim programmable valves: study of an explanted valve and successful programming in a patient.

    PubMed

    Wong, Sui-To; Wen, Eleanor; Fong, Dawson

    2013-08-01

    Malfunction of a Codman Hakim programmable valve due to jamming of its programmable component may necessitate shunt revision. The authors report a method for programming jammed Codman Hakim programmable valves by using a Strata II magnet and additional neodymium magnets. The programming method was derived after studying a jammed valve in the laboratory that was explanted from an 10-year-old boy with a history of fourth ventricle ependymoma. Programming the explanted valve with a Codman programmer failed, but rotating a Strata II magnet above the valve resulted in rotation of the spiral cam in the valve. It was found that the Strata II magnet could be used to program the jammed valve by rotating the magnet 90° or multiples of 90° above the valve. The strength of the magnetic field of the Strata II magnet was able to be increased by putting neodymium magnets on it. The programming method was then successfully used in a patient with a jammed Codman Hakim programmable valve. After successful programming using this method, clinical and radiological follow-up of the patient was advised.

  6. High-resolution subject-specific mitral valve imaging and modeling: experimental and computational methods.

    PubMed

    Toma, Milan; Bloodworth, Charles H; Einstein, Daniel R; Pierce, Eric L; Cochran, Richard P; Yoganathan, Ajit P; Kunzelman, Karyn S

    2016-12-01

    The diversity of mitral valve (MV) geometries and multitude of surgical options for correction of MV diseases necessitates the use of computational modeling. Numerical simulations of the MV would allow surgeons and engineers to evaluate repairs, devices, procedures, and concepts before performing them and before moving on to more costly testing modalities. Constructing, tuning, and validating these models rely upon extensive in vitro characterization of valve structure, function, and response to change due to diseases. Micro-computed tomography ([Formula: see text]CT) allows for unmatched spatial resolution for soft tissue imaging. However, it is still technically challenging to obtain an accurate geometry of the diastolic MV. We discuss here the development of a novel technique for treating MV specimens with glutaraldehyde fixative in order to minimize geometric distortions in preparation for [Formula: see text]CT scanning. The technique provides a resulting MV geometry which is significantly more detailed in chordal structure, accurate in leaflet shape, and closer to its physiological diastolic geometry. In this paper, computational fluid-structure interaction (FSI) simulations are used to show the importance of more detailed subject-specific MV geometry with 3D chordal structure to simulate a proper closure validated against [Formula: see text]CT images of the closed valve. Two computational models, before and after use of the aforementioned technique, are used to simulate closure of the MV.

  7. Cardiac autotransplantation for the treatment of permanent atrial fibrillation combined with mitral valve disease.

    PubMed

    Troise, Giovanni; Brunelli, Federico; Cirillo, Marco; Amaducci, Andrea; Mhagna, Zen; Tomba, Margherita Dalla; Tasca, Giordano; Quaini, Eugenio

    2003-01-01

    The results of current surgical options for the treatment of permanent atrial fibrillation associated with mitral valve surgery are widely different, particularly for extremely dilated left atria. The aim of this study is to assess the efficacy of cardiac autotransplantation in restoring a normal sinus rhythm via a consistent reduction in the left atrium volume associated with a complete isolation of the pulmonary veins. From April 2000 to April 2002, 28 patients (men/women, 5/23) underwent cardiac autotransplantation for the treatment of mitral disease and concomitant permanent atrial fibrillation (>1 year). A modified surgical technique derived from bicaval heart transplantation procedures maintained the connection of the right atrium with the inferior vena cava in all but 3 cases. In 2 patients, the mitral valve was repaired, and it was replaced in 26 patients. Associated procedures were 6 aortic valve replacements, 2 tricuspid valve annuloplasties, and 2 coronary revascularizations. No hospital deaths were recorded, but 1 patient died of pneumonia 3 months postoperatively. At a mean follow-up period of 17.2 +/- 6.7 months (range, 6-30 months), 24 patients (88.9%) were in sinus rhythm, and 3 (11.1%) were in atrial fibrillation. The Santa Cruz Score was 0 for 3 patients, 2 for 1 patient, and 4 for the remaining 23 patients (85.2%). The mean left atrial diameter decreased from 65.4 +/- 17.1 mm (range, 50-130 mm) before the operation to 48.4 +/- 5.6 mm (range, 37-78 mm) postoperatively (P <.001), and the mean left atrial volume decreased from 119 +/- 70.5 mL (range, 60-426 mL) to 69.1 +/- 35.1 mL (range, 31-226 mL) (P <.0001). Cardiac autotransplantation is a safe and effective surgical option for the treatment of permanent atrial fibrillation in patients with long-lasting mitral valve disease and severe enlargement of the left atrium.

  8. Statins for aortic valve stenosis.

    PubMed

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  9. Surgical RF ablation of atrial fibrillation in patients undergoing mitral valve repair for Barlow disease.

    PubMed

    Rostagno, Carlo; Droandi, G; Gelsomino, S; Carone, E; Gensini, G F; Stefàno, P L

    2013-01-01

    At present, limited experience exists on the treatment of atrial fibrillation (AF) in patients undergoing mitral valve repair (MVR) for Barlow disease. The aim of this investigation was to prospectively evaluate the radiofrequency ablation of AF in patients undergoing MVR for severe regurgitation due to Barlow disease. From January 1, 2007 to December 31, 2010, out of 85 consecutive patients with Barlow disease, 27 with AF underwent RF ablation associated with MVR. They were examined every 4 months in the first year after surgery and thereafter twice yearly. At follow-up, AF was observed in 4/25 (16.0%). NYHA (New York Heart Association) functional class improved significantly, with no patients in class III or IV (before surgery, 81.5% had been). Otherwise, among 58 patients in sinus rhythm, 6 (11%) developed AF during follow-up. No clinical or echocardiographic predictive factor was found in this subgroup. Results from our investigation suggest that radiofrequency ablation of AF in patients with Barlow disease undergoing MVR for severe regurgitation is effective and should be considered in every patient with Barlow disease and AF undergoing valve surgical repair. Copyright © 2013 S. Karger AG, Basel.

  10. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    PubMed Central

    Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie

    2017-01-01

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722

  11. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    PubMed

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  12. Non-functional tricuspid valve disease

    PubMed Central

    2017-01-01

    Only 75% of severe tricuspid regurgitation is classified as functional, or related primarily to pulmonary hypertension, right ventricular dysfunction, or a combination of both. Non-functional tricuspid regurgitation occurs when there is damage to the tricuspid leaflets, chordae, papillary muscles, or annulus, independent of right ventricular dysfunction or pulmonary hypertension. The entities that cause non-functional tricuspid regurgitation include rheumatic and myxomatous disease, acquired and genetic connective tissue disorders, endocarditis, sarcoid, pacing, RV biopsy, blunt trauma, radiation, carcinoid, ergot alkaloids, dopamine agonists, fenfluramine, cardiac tumors, atrial fibrillation, and congenital malformations. Over time, severe tricuspid regurgitation that is initially non-functional, can blend into functional tricuspid regurgitation, related to progressive right ventricular dysfunction. Symptoms and signs, including a falling right ventricular ejection fraction, cardiac cirrhosis, ascites, esophageal varices, and anasarca, may occur insidiously and late, but are associated with substantial morbidity and mortality. Attempted valve repair or replacement at late stages carries a high mortality. Crucial to following patients with severe non-functional tricuspid regurgitation is attention to echo quantification of the tricuspid regurgitation and right ventricular function, patient symptoms, and the physical examination. PMID:28706863

  13. Method and system for measuring gate valve clearances and seating force

    DOEpatents

    Casada, Donald A.; Haynes, Howard D.; Moyers, John C.; Stewart, Brian K.

    1996-01-01

    Valve clearances and seating force, as well as other valve operational parameters, are determined by measuring valve stem rotation during opening and closing operations of a translatable gate valve. The magnitude of the stem rotation, and the relative difference between the stem rotation on opening and closing provides valuable data on the valve internals in a non-intrusive manner.

  14. Quantification and comparison of the mechanical properties of four human cardiac valves.

    PubMed

    Pham, Thuy; Sulejmani, Fatiesa; Shin, Erica; Wang, Di; Sun, Wei

    2017-05-01

    Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease. A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model. The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older). Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. Most research on heart valve

  15. CALCIFIC AORTIC VALVE DISEASE: PART 1 – MOLECULAR PATHOGENETIC ASPECTS, HEMODYNAMICS AND ADAPTIVE FEEDBACKS

    PubMed Central

    Pasipoularides, Ares

    2016-01-01

    Aortic valvular stenosis (AVS), produced by calcific aortic valve disease (CAVD) causing reduced cusp opening, afflicts mostly older persons eventually requiring valve replacement. CAVD had been considered “degenerative,” but newer investigations implicate active mechanisms similar to atherogenesis—genetic predisposition and signaling pathways, lipoprotein deposits, chronic inflammation and calcification/osteogenesis. Consequently, CAVD may eventually be controlled/reversed by lifestyle and pharmacogenomics remedies. Its management should be comprehensive, embracing not only the valve but also the left ventricle and the arterial system with their interdependent morphomechanics/hemodynamics, which underlie the ensuing diastolic and systolic LV dysfunction. Compared to even a couple of decades ago, we now have an increased appreciation of genomic and cytomolecular pathogenetic mechanisms underlying CAVD. Future pluridisciplinary studies will characterize better and more completely its pathobiology, evolution and overall dynamics, encompassing intricate feedback processes involving specific signaling molecules and gene network cascades. They will herald more effective, personalized medicine treatments of CAVD/AVS. PMID:26891845

  16. Method and system for measuring gate valve clearances and seating force

    DOEpatents

    Casada, D.A.; Haynes, H.D.; Moyers, J.C.; Stewart, B.K.

    1996-01-30

    Valve clearances and seating force, as well as other valve operational parameters, are determined by measuring valve stem rotation during opening and closing operations of a translatable gate valve. The magnitude of the stem rotation, and the relative difference between the stem rotation on opening and closing provides valuable data on the valve internals in a non-intrusive manner. 8 figs.

  17. Management of significant left main coronary disease before and after trans-apical transcatheter aortic valve replacement in a patient with severe and complex arterial disease.

    PubMed

    Paradis, Jean-Michel; George, Isaac; Kodali, Susheel

    2013-09-01

    We report the case of an 81-year-old woman with symptomatic severe aortic stenosis, extremely significant peripheral arterial disease, and obstructive coronary artery disease who underwent percutaneous coronary intervention via a transaxillary conduit immediately before a trans-apical transcatheter aortic valve replacement performed with a transfemoral device. After deployment of the transcatheter heart valve, there was a left main coronary obstruction and the patient required an emergent PCI. This multifaceted case clearly underlines the importance of a well functioning heart team including the interventional cardiologist, the cardiovascular surgeon, and the echocardiographer. Copyright © 2013 Wiley Periodicals, Inc.

  18. Mitral valve prolapse and hyperthyroidism: effect of patient selection.

    PubMed

    Zullo, M A; Devereux, R B; Kramer-Fox, R; Lutas, E M; Brown, W T

    1985-11-01

    Patients with mitral valve prolapse and hyperthyroidism have common symptoms; the most outstanding symptom is palpitation. To determine whether or not common symptoms contributed to the reported association of these conditions, we evaluated 220 patients with symptomatic mitral valve prolapse and 216 first-degree relatives in 72 families; 65 relatives with mitral valve prolapse and 151 relatives without mitral valve prolapse, all greater than or equal to 16 years of age. Thirty subjects, aged 49 +/- 13 years (p less than 0.025 vs entire study group), had thyroid disease (23 subjects had definite thyroid disease, seven subjects had probable); 27 of 30 subjects with thyroid disease (90%) were female (p less than 0.005). The age- and sex-adjusted prevalence of hyperthyroidism was significantly higher in probands with mitral valve prolapse than in family members without mitral valve prolapse (3.5% vs 0%, p = 0.03), while an intermediate prevalence of hyperthyroidism (2.2%) was observed in family members with mitral valve prolapse. Thus, the prevalence of hyperthyroidism is increased among symptomatic patients with mitral valve prolapse as compared to family members without mitral valve prolapse, but the prevalence of thyroid conditions is similar among family members with or without this condition. These findings are explained by the effect of common symptoms on clinical detection of both mitral valve prolapse and hyperthyroidism.

  19. Fluid Dynamics of the Heart and its Valves

    NASA Astrophysics Data System (ADS)

    Peskin, Charles S.

    1997-11-01

    The fluid dynamics of the heart involve the interaction of blood, a viscous incompressible fluid, with the flexible, elastic, fiber-reinforced heart valve leaflets that are immersed in that fluid. Neither the fluid motion nor the valve leaflet motion are known in advance: both must be computed simultaneously by solving their coupled equations of motion. This can be done by the immersed boundary method(Peskin CS and McQueen DM: A general method for the computer simulation of biological systems interacting with fluids. In: Biological Fluid Dynamics (Ellington CP and Pedley TJ, eds.), The Company of Biologists Limited, Cambridge UK, 1995, pp. 265-276.), which can be extended to incorporate the contractile fiber architecture of the muscular heart walls as well as the valve leaflets and the blood. In this way we arrive at a three-dimensional computer model of the heart(Peskin CS and McQueen DM: Fluid dynamics of the heart and its valves. In: Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology (Othmer HG, Adler FR, Lewis MA, and Dallon JC, eds.), Prentice-Hall, Englewood Cliffs NJ, 1996, pp. 309-337.), which can be used as a test chamber for the design of prosthetic cardiac valves, and also to study the function of the heart in health and in disease. Numerical solutions of the equations of cardiac fluid dynamics obtained by the immersed boundary method will be presented in the form of a video animation of the beating heart.

  20. Prosthetic valve endocarditis.

    PubMed Central

    Moore-Gillon, J; Eykyn, S J; Phillips, I

    1983-01-01

    During 1965 to 1982, 32 episodes of infective endocarditis on prosthetic valves in 30 patients were treated at this hospital. In early endocarditis (presenting within four months of operation) staphylococci were the organisms most commonly responsible. Early endocarditis appears to be declining in incidence and is largely preventable; sternal sepsis was the main predisposing factor, requiring urgent and effective treatment. Streptococci were the most common organisms in late onset disease, but as with natural valve endocarditis a wide range or organisms was responsible. All but one of the patients with early onset disease were treated conservatively, but mortality was high; prompt surgical replacement of infected prostheses is probably indicated in such patients. Medical management was effective in most patients with late onset disease, and for them early surgical intervention may not be justified. PMID:6412805

  1. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    PubMed Central

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  2. [Ministernotomy: a preliminary experience in heart valve surgery].

    PubMed

    Kovarević, Pavle; Mihajlović, Bogoljub; Velicki, Lazar; Redzek, Aleksandar; Ivanović, Vladimir; Komazec, Nikola

    2011-05-01

    The last decade of the 20th century brought up a significant development in the field of minimally invasive approaches to the valvular heart surgery. Potential benefits of this method are: good esthetic appearance, reduced pain, reduction of postoperative hemorrhage and incidence of surgical site infection, shorter postoperative intensive care units (ICU) period and overall in-hospital period. Partial upper median stemotomy currently presents as a state-of-the art method for minimally invasive surgery of cardiac valves. The aim of this study was to report on initial experience in application of this surgical method in the surgery of mitral and aortic valves. The study was designed and conducted in a prospective manner and included all the patients who underwent minimally invasive cardiac valve surgery through the partial upper median stemotomy during the period November 2008 - August 2009. We analyzed the data on mean age of patients, mean extubation time, mean postoperative drainage, mean duration of hospital stay, as well as on occurance of postoperative complications (postoperative bleeding, surgical site infection and cerebrovascular insult). During the observed period, in the Institute for Cardiovascular Diseases of Vojvodina, Clinic for Cardiovascular Surgery, 17 ministernotomies were performed, with 14 aortic valve replacements (82.35%) and 3 mitral valve replacements (17.65%). Mean age of the patients was 60.78 +/- 12.99 years (64.71% males, 35.29% females). Mean extubation time was 12.53 +/- 8.87 hours with 23.5% of the patients extubated in less than 8 hours. Mean duration of hospital stay was 12.35 +/- 10.17 days (in 29.4% of the patients less than 8 days). Mean postoperative drainage was 547.06 +/- 335.2 mL. Postoperative complications included: bleeding (5.88%) and cerebrovascular insult (5.88%). One patient (5.88%) required conversion to full stemotomy. Partial upper median sternotomy represents the optimal surgical method for the interventions on the

  3. Stemless Ball Valve

    NASA Technical Reports Server (NTRS)

    Burgess, Robert K.; Yakos, David; Walthall, Bryan

    2012-01-01

    This invention utilizes a new method of opening and closing a ball valve. Instead of rotating the ball with a perpendicular stem (as is the case with standard ball valves), the ball is rotated around a fixed axis by two guide pins. This innovation eliminates the leak point that is present in all standard ball valves due to the penetration of an actuation stem through the valve body. The VOST (Venturi Off-Set-Technology) valve has been developed for commercial applications. The standard version of the valve consists of an off-set venturi flow path through the valve. This path is split at the narrowest portion of the venturi, allowing the section upstream from the venturi to be rotated. As this rotation takes place, the venturi becomes restricted as one face rotates with respect to the other, eventually closing off the flow path. A spring-loaded seal made of resilient material is embedded in the upstream face of the valve, making a leak-proof seal between the faces; thus a valve is formed. The spring-loaded lip seal is the only seal that can provide a class six, or bubble-tight, seal against the opposite face of the valve. Tearing action of the seal by high-velocity gas on this early design required relocation of the seal to the downstream face of the valve. In the stemless embodiment of this valve, inner and outer magnetic cartridges are employed to transfer mechanical torque from the outside of the valve to the inside without the use of a stem. This eliminates the leak path caused by the valve stems in standard valves because the stems penetrate through the bodies of these valves.

  4. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    PubMed Central

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  5. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    PubMed

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  6. Shear-Sensitive Genes in Aortic Valve Endothelium

    PubMed Central

    Fernández Esmerats, Joan; Heath, Jack

    2016-01-01

    Abstract Significance: Currently, calcific aortic valve disease (CAVD) is only treatable through surgical intervention because the specific mechanisms leading to the disease remain unclear. In this review, we explore the forces and structure of the valve, as well as the mechanosensors and downstream signaling in the valve endothelium known to contribute to inflammation and valve dysfunction. Recent Advances: While the valvular structure enables adaptation to dynamic hemodynamic forces, these are impaired during CAVD, resulting in pathological systemic changes. Mechanosensing mechanisms—proteins, sugars, and membrane structures—at the surface of the valve endothelial cell relay mechanical signals to the nucleus. As a result, a large number of mechanosensitive genes are transcribed to alter cellular phenotype and, ultimately, induce inflammation and CAVD. Transforming growth factor-β signaling and Wnt/β-catenin have been widely studied in this context. Importantly, NADPH oxidase and reactive oxygen species/reactive nitrogen species signaling has increasingly been recognized to play a key role in the cellular response to mechanical stimuli. In addition, a number of valvular microRNAs are mechanosensitive and may regulate the progression of CAVD. Critical Issues: While numerous pathways have been described in the pathology of CAVD, no treatment options are available to avoid surgery for advanced stenosis and calcification of the aortic valve. More work must be focused on this issue to lead to successful therapies for the disease. Future Directions: Ultimately, a more complete understanding of the mechanisms within the aortic valve endothelium will lead us to future therapies important for treatment of CAVD without the risks involved with valve replacement or repair. Antioxid. Redox Signal. 25, 401–414. PMID:26651130

  7. Cavitation guide for control valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines sixmore » cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.« less

  8. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    PubMed

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% <1 year); 86 (45%) had a preceding balloon valvuloplasty. The indications for the procedure were stenotic (n = 123; 64%), regurgitant (n = 63; 33%) or combined (n = 7; 4%) disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association

  9. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    PubMed

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  10. Neurotrophin 3 upregulates proliferation and collagen production in human aortic valve interstitial cells: a potential role in aortic valve sclerosis.

    PubMed

    Yao, Qingzhou; Song, Rui; Ao, Lihua; Cleveland, Joseph C; Fullerton, David A; Meng, Xianzhong

    2017-06-01

    Calcific aortic valve disease (CAVD) is a leading cardiovascular disorder in the elderly. Diseased aortic valves are characterized by sclerosis (fibrosis) and nodular calcification. Sclerosis, an early pathological change, is caused by aortic valve interstitial cell (AVIC) proliferation and overproduction of extracellular matrix (ECM) proteins. However, the mechanism of aortic valve sclerosis remains unclear. Recently, we observed that diseased human aortic valves overexpress growth factor neurotrophin 3 (NT3). In the present study, we tested the hypothesis that NT3 is a profibrogenic factor to human AVICs. AVICs isolated from normal human aortic valves were cultured in M199 growth medium and treated with recombinant human NT3 (0.10 µg/ml). An exposure to NT3 induced AVIC proliferation, upregulated the production of collagen and matrix metalloproteinase (MMP), and augmented collagen deposition. These changes were abolished by inhibition of the Trk receptors. NT3 induced Akt phosphorylation and increased cyclin D1 protein levels in a Trk receptor-dependent fashion. Inhibition of Akt abrogated the effect of NT3 on cyclin D1 production. Furthermore, inhibition of either Akt or cyclin D1 suppressed NT3-induced cellular proliferation and MMP-9 and collagen production, as well as collagen deposition. Thus, NT3 upregulates cellular proliferation, ECM protein production, and collagen deposition in human AVICs. It exerts these effects through the Trk-Akt-cyclin D1 cascade. NT3 is a profibrogenic mediator in human aortic valve, and overproduction of NT3 by aortic valve tissue may contribute to the mechanism of valvular sclerosis. Copyright © 2017 the American Physiological Society.

  11. Impact of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mechanical mitral valve replacement for rheumatic mitral valve disease.

    PubMed

    Wang, Bin; Xu, Zhi-yun; Han, Lin; Zhang, Guan-xin; Lu, Fang-lin; Song, Zhi-gang

    2013-03-01

    The prognostic significance of preoperative atrial fibrillation on mitral valve replacement remains unclear. The aim of this study was to explore the effects of the presence of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mitral valve replacement for rheumatic valve disease. A retrospective analysis was performed on a total of 793 patients who underwent mitral valve replacement with or without tricuspid valve repair in our hospital. The patients selected were divided into two groups according to preoperative rhythm status. Patients with preoperative atrial fibrillation were assigned to the AF group, while patients in preoperative sinus rhythm were assigned to the SR group. Postoperative follow-up was performed by outpatient visits, as well as by telephone and written correspondence. Data gathered included survivorship, postoperative complications, left ventricular function and tricuspid regurgitation. For patients with atrial fibrillation vs those in sinus rhythm, there was no difference in postoperative mortality and morbidity. Follow-up was a mean of 8.6 ± 2.4 years. For patients with preoperative atrial fibrillation, 10-year survival from a Kaplan-Meier curve was 88.7%, compared with 96.6% in patients with preoperative sinus rhythm (P = 0.002). Multivariate analysis identified low left ventricular ejection fraction, older age, large left atrium and preoperative atrial fibrillation as significant adverse predictors for overall survival. Freedom from thromboembolism complications at 13 years was lower for patients with preoperative atrial fibrillation without maze procedure and left atrial appendage ligation, compared with that for patients with preoperative sinus rhythm without maze procedure and left atrial appendage ligation, and patients with concomitant maze procedure and left atrial appendage ligation (76.3 vs 94.8 vs 94.0%, respectively; P = 0.001). On echocardiography, the proportion of patients with significant tricuspid

  12. System and method for controlling engine knock using electro-hydraulic valve actuation

    DOEpatents

    Brennan, Daniel G

    2013-12-10

    A control system for an engine includes a knock control module and a valve control module. The knock control module adjusts a period that one or more of an intake valve and an exhaust valve of a cylinder are open based on engine knock corresponding to the cylinder. The valve control module, based on the adjusted period, controls the one or more of the intake valve and the exhaust valve using one or more hydraulic actuators.

  13. Triple-orifice valve repair in severe Barlow disease with multiple-jet mitral regurgitation: report of mid-term experience.

    PubMed

    Fucci, Carlo; Faggiano, Pompilio; Nardi, Matilde; D'Aloia, Antonio; Coletti, Giuseppe; De Cicco, Giuseppe; Latini, Leonardo; Vizzardi, Enrico; Lorusso, Roberto

    2013-09-10

    Barlow disease represents a surgical challenge for mitral valve repair (MR) in the presence of mitral insufficiency (MI) with multiple regurgitant jets. We hereby present our mid-term experience using a modified edge-to-edge technique to address this peculiar MI. From March 2003 till December 2010, 25 consecutive patients (mean age 54 ± 7 years, 14 males) affected by severe Barlow disease with multiple regurgitant jets were submitted to MR. Preoperative transesophageal echo (TEE) in all the cases showed at least 2 regurgitant jets, involving one or both leaflets in more than one segment. In all the patients, a triple orifice valve (TOV) repair with annuloplasty was performed. Intra-operative TEE and postoperative transthoracic echocardiography (TTE) were carried out to evaluate results of the TOV repair. There was no in-hospital death and one late death (non-cardiac related). At intra-operative TEE, the three orifices showed a mean total valve area of 2.9 ± 0.1cm(2) (range 2.5-3.3 cm(2)) with no residual regurgitation (2 cases of trivial MI) and no sign of valve stenosis (mean transvalvular gradient 4.6 ± 1.5 mmHg). At follow up (mean 38 ± 22 months), TTE showed favourable MR and no recurrence of significant MI (6 cases of trivial and 1 of mild MI). Stress TTE was performed in 5 cases showing persistent effective valve function (2 cases of trivial MI at peak exercise). All the patients showed significant NYHA functional class improvement. This report indicates that the TOV technique is effective in correcting complex Barlow mitral valves with multiple jets. Further studies are required to confirm long-term applicability and durability in more numerous clinical cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. The importance of echocardiography in transcatheter aortic valve implantation.

    PubMed

    Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin

    2014-01-01

    Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.

  15. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  16. Fluid mechanics of artificial heart valves.

    PubMed

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  17. Preliminary Investigation of Cardiovascular-Renal Disorders in Dogs with Chronic Mitral Valve Disease.

    PubMed

    Martinelli, E; Locatelli, C; Bassis, S; Crosara, S; Paltrinieri, S; Scarpa, P; Spalla, I; Zanaboni, A M; Quintavalla, C; Brambilla, P

    2016-09-01

    Veterinary literature lacks data about cardiovascular-renal disorders (CvRD) and cardiorenal-anemia syndrome (CRAS) in dogs. A direct correlation exists between ACVIM class and IRIS stage; chronic kidney disease (CKD) complicates chronic mitral valve disease (CMVD) more often than does anemia in dogs. One hundred and fifty-eight client-owned dogs with CMVD. Signalment, physical examination findings, electrocardiography, thoracic radiographs, echocardiography, and blood analysis were retrospectively evaluated to assess the prevalence of CKD and anemia in dogs with CMVD and to investigate the relationships among ACVIM class, IRIS stage, and survival. The prevalence of CKD and anemia in dogs with CMVD was significantly higher than in the general population of dogs. Dogs being treated for heart failure had a significantly higher prevalence of CKD than did dogs that had not received treatment. A statistically significant direct correlation was found between ACVIM class and IRIS stage. Severe heart disease, severe renal disease or both, furosemide administration, and advanced age at diagnosis of heart disease were associated with shorter survival time. Survival time of dogs affected by CvRD was statistically shorter than survival time of dogs affected by CMVD alone. Chronic mitral valve disease is associated with increased prevalence of CKD and anemia in dogs. Treatment for medical management of heart failure may play a role in inducing CKD. Class of heart disease and IRIS stage were directly correlated. Cardiovascular-renal disorders decrease survival time compared to the only presence of CMVD alone, whereas anemia does not play a central role in worsening heart function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  18. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    PubMed

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Self-expandable CoreValve implantation without contrast media.

    PubMed

    Bruschi, Giuseppe; Colombo, Paola; De Marco, Federico; Barosi, Alberto; Mauri, Silvia; Klugmann, Silvio

    2016-09-01

    Transcatheter aortic valve implantation has been designed to treat high-risk surgical patients affected by severe aortic stenosis, many of whom are affected by chronic kidney disease. To perform transcatheter self-expandable valve implantation, multiple contrast injections are required to monitor the procedure, so these patients are at increased risk of acute kidney injury. We described self-expandable transcatheter aortic valve implantation without contrast media in an 80-year-old man affected by severe aortic stenosis and endstage chronic kidney disease. © The Author(s) 2015.

  20. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  1. Sleep-Disordered Breathing in Patients with Pulmonary Valve Incompetence Complicating Congenital Heart Disease.

    PubMed

    Miles, Susan; Ahmad, Waheed; Bailey, Amy; Hatton, Rachael; Boyle, Andrew; Collins, Nicholas

    2016-12-01

    Long standing pulmonary regurgitation results in deleterious effects on right heart size and function with late consequences of right heart volume overload including ventricular dilatation, propensity to arrhythmia and right heart failure. As sleep disordered breathing may predispose to elevations in pulmonary vascular resistance and associated negative effects on right ventricular function, we sought to assess this in patients with underlying congenital heart disease. We performed a pilot study to evaluate the incidence of sleep-disordered breathing in a patient population with a history of long standing pulmonary valve incompetence in patients with congenital heart disease using overnight oximetry. Patients with a background of tetralogy of Fallot repair or residual pulmonary incompetence following previous pulmonary valve intervention for congenital pulmonary stenosis were included. Twenty-two patients underwent overnight oximetry. The mean age of the cohort was 34.3 ± 15.2 years with no patients observed to have severe underlying pulmonary hypertension. Abnormal overnight oximetry was seen in 13/22 patients (59.1%) with 2/22 (9.1%) patients considered to have severe abnormalities. An important proportion of patients with a background of pulmonary incompetence complicating congenital heart disease are prone to the development of sleep-disordered breathing as assessed by overnight oximetry. Further study into the prevalence and mechanisms of sleep-disordered breathing in a larger cohort are warranted. © 2016 Wiley Periodicals, Inc.

  2. The German Aortic Valve Registry (GARY): in-hospital outcome

    PubMed Central

    Hamm, Christian W.; Möllmann, Helge; Holzhey, David; Beckmann, Andreas; Veit, Christof; Figulla, Hans-Reiner; Cremer, J.; Kuck, Karl-Heinz; Lange, Rüdiger; Zahn, Ralf; Sack, Stefan; Schuler, Gerhard; Walther, Thomas; Beyersdorf, Friedhelm; Böhm, Michael; Heusch, Gerd; Funkat, Anne-Kathrin; Meinertz, Thomas; Neumann, Till; Papoutsis, Konstantinos; Schneider, Steffen; Welz, Armin; Mohr, Friedrich W.

    2014-01-01

    Background Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. Methods and results A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). Conclusion The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients. PMID:24022003

  3. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    PubMed

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  4. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    PubMed Central

    Abulon, Dina Joy; Charles, Martin; Charles, Daniel E

    2015-01-01

    Purpose To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP), fluid leakage, and vitreous incarceration during simulated vitrectomy. Methods Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes. Results In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005), and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05) and 27-gauge (P<0.05) non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas. Conclusion Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy. PMID:26445520

  5. Heart Valve Biomechanics and Underlying Mechanobiology

    PubMed Central

    Ayoub, Salma; Ferrari, Giovanni; Gorman, Robert C.; Gorman, Joseph H.; Schoen, Frederick J.; Sacks, Michael S.

    2017-01-01

    Heart valves control unidirectional blood flow within the heart during the cardiac cycle. They have a remarkable ability to withstand the demanding mechanical environment of the heart, achieving lifetime durability by processes involving the ongoing remodeling of the extracellular matrix. The focus of this review is on heart valve functional physiology, with insights into the link between disease-induced alterations in valve geometry, tissue stress, and the subsequent cell mechanobiological responses and tissue remodeling. We begin with an overview of the fundamentals of heart valve physiology and the characteristics and functions of valve interstitial cells (VICs). We then provide an overview of current experimental and computational approaches that connect VIC mechanobiological response to organ- and tissue-level deformations and improve our understanding of the underlying functional physiology of heart valves. We conclude with a summary of future trends and offer an outlook for the future of heart valve mechanobiology, specifically, multiscale modeling approaches, and the potential directions and possible challenges of research development. PMID:27783858

  6. Role of modern 3D echocardiography in valvular heart disease

    PubMed Central

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  7. Predictors of survival in octogenarians after mitral valve surgery for degenerative disease: The Mitral Surgery in Octogenarians study.

    PubMed

    Chivasso, Pierpaolo; Bruno, Vito D; Farid, Shakil; Malvindi, Pietro Giorgio; Modi, Amit; Benedetto, Umberto; Ciulli, Franco; Abu-Omar, Yasir; Caputo, Massimo; Angelini, Gianni D; Livesey, Steve; Vohra, Hunaid A

    2018-04-01

    An increasing number of octogenarians are referred to undergo mitral valve surgery for degenerative disease, and percutaneous approaches are being increasingly used in this subgroup of patients. We sought to determine the survival and its predictors after Mitral Valve Surgery in Octogenarians (MiSO) in a multicenter UK study of high-volume specialized centers. Pooled data from 3 centers were collected retrospectively. To identify the predictors of short-term composite outcome of 30 days mortality, acute kidney injury, and cerebrovascular accident, a multivariable logistic regression model was developed. Multiple Cox regression analysis was performed for late mortality. Kaplan-Meier curves were generated for long-term survival in various subsets of patients. Receiver operating characteristic analysis was done to determine the predictive power of the logistic European System for Cardiac Operative Risk Evaluation. A total of 247 patients were included in the study. The median follow-up was 2.9 years (minimum 0, maximum 14 years). A total of 150 patients (60.7%) underwent mitral valve repair, and 97 patients (39.3%) underwent mitral valve replacement. Apart from redo cardiac surgery (mitral valve repair 6 [4%] vs mitral valve replacement 11 [11.3%], P = .04) and preoperative atrial fibrillation (mitral valve repair 79 [52.6%] vs mitral valve replacement 34 [35.1%], P < .01), there was no significant difference in terms of any other preoperative characteristics between the 2 groups. Patient operative risk, as estimated by logistic European System for Cardiac Operative Risk Evaluation, was lower in the mitral valve repair group (10.2 ± 11.8 vs 13.7 ± 15.2 in mitral valve replacement; P = .07). No difference was found between groups for duration of cardiopulmonary bypass and aortic crossclamp times. The 30-day mortality for the whole cohort was 13.8% (mitral valve repair 4.7% vs mitral valve replacement 18.6%; P < .01). No differences were found in terms

  8. Surgical treatment of tricuspid regurgitation after mitral valve surgery: a retrospective study in China

    PubMed Central

    2012-01-01

    Background Functional tricuspid regurgitation (TR) occurs in patients with rheumatic mitral valve disease even after mitral valve surgery. The aim of this study was to analyze surgical results of TR after previous successful mitral valve surgery. Methods From September 1996 to September 2008, 45 patients with TR after previous mitral valve replacement underwent second operation for TR. In those, 43 patients (95.6%) had right heart failure symptoms (edema of lower extremities, ascites, hepatic congestion, etc.) and 40 patients (88.9%) had atrial fibrillation. Twenty-six patients (57.8%) were in New York Heart Association (NYHA) functional class III, and 19 (42.2%) in class IV. Previous operations included: 41 for mechanical mitral valve replacement (91.1%), 4 for bioprosthetic mitral valve replacement (8.9%), and 7 for tricuspid annuloplasty (15.6%). Results The tricuspid valves were repaired with Kay's (7 cases, 15.6%) or De Vega technique (4 cases, 8.9%). Tricuspid valve replacement was performed in 34 cases (75.6%). One patient (2.2%) died. Postoperative low cardiac output (LCO) occurred in 5 patients and treated successfully. Postoperative echocardiography showed obvious reduction of right atrium and ventricle. The anterioposterior diameter of the right ventricle decreased to 25.5 ± 7.1 mm from 33.7 ± 6.2 mm preoperatively (P < 0. 05). Conclusion TR after mitral valve replacement in rheumatic heart disease is a serious clinical problem. If it occurs or progresses late after mitral valve surgery, tricuspid valve annuloplasty or replacement may be performed with satisfactory results. Due to the serious consequence of untreated TR, aggressive treatment of existing TR during mitral valve surgery is recommended. PMID:22490269

  9. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  10. Pulmonary hypertension in dogs with mitral regurgitation attributable to myxomatous valve disease.

    PubMed

    Chiavegato, David; Borgarelli, Michele; D'Agnolo, Gino; Santilli, Roberto A

    2009-01-01

    Pulmonary hypertension has been associated with mitral insufficiency caused by chronic degenerative valve disease in dogs. Our aim was to search for associations between left atrial to aortic root ratio, end-systolic and end-diastolic volume indices, and changes in the right ventricular to right atrial pressure gradient as estimated by the peak velocity of tricuspid regurgitation in dogs with chronic degenerative valve disease and different classes of heart failure. Dogs, for which follow-up was available were evaluated for changes in the right ventricular to right atrial systolic pressure gradient over time. Three hundred and forty-four dogs were studied; 51 in the International Small Animal Cardiac Health Council class la, 75 in class 1b, 113 in class 2, 97 in class 3a, and 8 in class 3b. The mean values for right ventricular to right atrial systolic pressure gradient, end-systolic volume index, end-diastolic volume index, and left atrial to aortic ratio were 49.2 +/- 17.1 mmHg, 149.12 +/- 60.8 and 37.7 +/- 21.6 ml/m2, and 1.9 +/- 0.5, respectively. A weak positive correlation was found between the right ventricular to right atrial systolic pressure gradient and the left atrial to aorta ratio (r = 0.242, P < 0.0001), end-diastolic volume index (r = 0.242, P < 0.0001), and end-systolic volume index (r = 0.129, P < 0.001). Follow up was available for 49 dogs. Of these, 18 had an increased, 12 a decreased, and 19 a stable right ventricular to right atrial systolic pressure gradient despite therapy. The equivalence point between the sensitivity and specificity curves of about 80% in the coincident point corresponded to a right ventricular to right atrial systolic pressure gradient of 48 mmHg. Our results suggest an association between the progressive nature of chronic degenerative mitral valve disease and pulmonary hypertension. It is of clinical interest that, with a right ventricular to right atrial systolic pressure gradient pressure gradient at or above 48 mm

  11. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    PubMed

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease.

    PubMed

    van Slooten, Ymkje J; van Melle, Joost P; Freling, Hendrik G; Bouma, Berto J; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C; Sieswerda, Gertjan T; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A; Pieper, Petronella G

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in life. However, the prevalence and clinical consequences of aortic PPM in ACHD are presently unknown. From the national Dutch Congenital Corvitia (CONCOR) registry, we identified 207 ACHD with an aortic valve prosthesis for this cross-sectional cohort study. Severe PPM was defined as an indexed effective orifice area ≤0.65 cm2/m2 and moderate PPM as an indexed orifice area ≤0.85 cm2/m2 measured using echocardiography. Exercise capacity was reported as percentage of predicted exercise capacity (PPEC). Of the 207 patients, 68% was male, 71% had a mechanical prosthesis and mean age at inclusion was 43.9 years ±11.4. The prevalence of PPM was 42%, comprising 23% severe PPM and 19% moderate PPM. Prevalence of PPM was higher in patients with mechanical prostheses (p<0.001). PPM was associated with poorer exercise capacity (mean PPEC 84% vs. 92%; p=0.048, mean difference =-8.3%, p=0.047). Mean follow-up was 2.6±1.1 years during which New York Heart Association (NYHA) class remained stable in most patients. PPM showed no significant effect on death or hospitalisation during follow-up (p=0.218). In this study we report a high prevalence (42%) of PPM in ACHD with an aortic valve prosthesis and an independent association of PPM with diminished exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Concomitant coronary artery bypass graft and aortic and mitral valve replacement for rheumatic heart disease: short- and mid-term outcomes.

    PubMed

    Davarpasand, Tahereh; Hosseinsabet, Ali; Jalali, Arash

    2015-09-01

    It has been reported that the short-term mortality of concomitant aortic and mitral valve replacement (AVR and MVR) is considerable and concomitant coronary artery bypass graft (CABG) has adverse effects on the survival of patients with valve replacement surgery. We summarize the short- and mid-term outcome after concomitant CABG, AVR and MVR in our centre. Between 2003 and 2013, 103 patients (68 males, 35 females, age: 60.1 ± 10.1 years) underwent CABG, AVR and MVR for rheumatic heart disease (RHD) and coronary artery disease (CAD). The median follow-up was 47.6 months. Most of the patients were asymptomatic at rest. We analysed demographic, clinical and operative data of patients to define independent predictors of overall survival, cardiac event-free survival as well as cardiac death. The rate of 30-day survival was 93% (n = 96). The corresponding rates of overall survival and cardiac event-free survival and the cumulative incidence rate of cardiac death at 1 year were 80.2, 77.3 and 10.9%; the same at 4 years were 73.7, 64.6 and 15.8%. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 96.2, 95.3, 94.7, 81.6 and 97.7% at 1 year. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 93.5, 91.0, 91.4, 73.5 and 95.5% at 4 years. The independent predictors of overall survival were age, cigarette smoking, chronic kidney diseases and balloon pump insertion. The independent predictors of cardiac event-free survival were age and previous myocardial infarction, while age, cigarette smoking, history of cerebrovascular

  14. Atrial fibrillation surgery in nonrheumatic mitral valve disease.

    PubMed

    Gillinov, Marc

    2007-12-01

    Atrial fibrillation (AF) is present in 30-50% of patients presenting for mitral valve surgery. If left untreated, AF in these patients is associated with increased morbidity and, possibly, increased mortality. Therefore, concomitant management of the arrhythmia is indicated in most mitral valve patients with preexisting AF. The cut-and-sew Cox-Maze III procedure is extremely effective, eliminating AF in 80-95%; however, it has been supplanted by newer operations that rely upon alternate energy sources to create lines of conduction block. Early and midterm results are good with a variety of technologies. Choice of lesion set remains a matter of debate, but success of ablation appears to be enhanced by a biatrial lesion set and exceeds 90% in some series. Targeted areas for improvement in combined mitral valve surgery and AF ablation include acceptance of uniform standards for reporting results, development of improved technology for ablation and intraoperative assessment, and creation of instrumentation that facilitates minimally invasive approaches.

  15. Intelligent Flow Control Valve

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  16. Aortic Valve Regurgitation

    MedlinePlus

    ... the main artery that leads to the body (aorta) doesn't close properly, which causes some blood ... Other diseases. Other rare conditions can enlarge the aorta and aortic valve and lead to regurgitation, including ...

  17. Semi-active compressor valve

    DOEpatents

    Brun, Klaus; Gernentz, Ryan S.

    2010-07-27

    A method and system for fine-tuning the motion of suction or discharge valves associated with cylinders of a reciprocating gas compressor, such as the large compressors used for natural gas transmission. The valve's primary driving force is conventional, but the valve also uses an electromagnetic coil to sense position of the plate (or other plugging element) and to provide an opposing force prior to impact.

  18. Patient-specific pediatric silicone heart valve models based on 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.

  19. Cells for tissue engineering of cardiac valves.

    PubMed

    Jana, Soumen; Tranquillo, Robert T; Lerman, Amir

    2016-10-01

    Heart valve tissue engineering is a promising alternative to prostheses for the replacement of diseased or damaged heart valves, because tissue-engineered valves have the ability to remodel, regenerate and grow. To engineer heart valves, cells are harvested, seeded onto or into a three-dimensional (3D) matrix platform to generate a tissue-engineered construct in vitro, and then implanted into a patient's body. Successful engineering of heart valves requires a thorough understanding of the different types of cells that can be used to obtain the essential phenotypes that are expressed in native heart valves. This article reviews different cell types that have been used in heart valve engineering, cell sources for harvesting, phenotypic expression in constructs and suitability in heart valve tissue engineering. Natural and synthetic biomaterials that have been applied as scaffold systems or cell-delivery platforms are discussed with each cell type. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Modeling the Mitral Valve

    NASA Astrophysics Data System (ADS)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  1. The mechanobiology of mitral valve function, degeneration, and repair

    PubMed Central

    Richards, Jennifer M.; Farrar, Emily J.; Kornreich, Bruce G.; Moïse, N. Sydney; Butcher, Jonathan T.

    2013-01-01

    In degenerative valve disease, the highly organized mitral valve leaflet matrix stratification is progressively destroyed and replaced with proteoglycan rich, mechanically inadequate tissue. This is driven by the actions of originally quiescent valve interstitial cells that become active contractile and migratory myofibroblasts. While treatment for myxomatous mitral valve disease in humans ranges from repair to total replacement, therapies in dogs focus on treating the consequences of the resulting mitral regurgitation. The fundamental gap in our understanding is how the resident valve cells respond to altered mechanical signals to drive tissue remodeling. Despite the pathological similarities and high clinical occurrence, surprisingly little mechanistic insight has been gleaned from the dog. This review presents what is known about mitral valve mechanobiology from clinical, in vivo, and in vitro data. There are a number of experimental strategies already available to pursue this significant opportunity, but success requires the collaboration between veterinary clinicians, scientists, and engineers. PMID:22366572

  2. [Left-sided native valve endocarditis by coagulase-negative staphylococci: an emerging disease].

    PubMed

    Haro, Juan Luis; Lomas, José M; Plata, Antonio; Ruiz, Josefa; Gálvez, Juan; de la Torre, Javier; Hidalgo-Tenorio, Carmen; Reguera, José M; Márquez, Manuel; Martínez-Marcos, Francisco; de Alarcón, Arístides

    2008-05-01

    To describe the epidemiological, clinical, and prognostic characteristics of patients with left-sided native valve endocarditis (LNVE) caused by coagulase-negative staphylococci (CoNS). Prospective multicenter study of endocarditis cases reported in the Andalusian Cohort for the Study of Cardiovascular Infections between 1984 and 2005. Among 470 cases of LNVE, 39 (8.3%) were caused by CoNS, a number indicating a 30% increase in the incidence of this infection over the last decade. The mean age of affected patients was 58.32 +/- 15 years and 27 (69.2%) were men. Twenty-one patients (53.8%) had previous known valve disease and half the episodes were considered nosocomial (90% of them from vascular procedures). Median time interval from the onset of symptoms to diagnosis was 14 days (range: 1-120). Renal failure (21 cases, 53.8%), intracardiac damage (11 cases, 28.2%), and central nervous system involvement (10 cases, 25.6%) were the most frequent complications. There were only 3 cases (7.7%) of septic shock. Surgery was performed in 18 patients (46.2%). Nine patients (23.1%) died, overall. Factors associated with higher mortality in the univariate analysis were acute renal failure (P = 0.023), left-sided ventricular failure (P = 0.047), and time prior to diagnosis less than 21 days (P = 0.018). As compared to LNVE due to other microorganisms, the patients were older (P = 0.018), had experienced previous nosocomial manipulation as the source of bacteremia (P < 0.001), and developed acute renal failure more frequently (P = 0.001). Mortality of LNVE due to CoNS was lower than mortality in Staphylococcus aureus infection, but higher than in Streptococcus viridans infection. Left-sided native valve endocarditis due to CoNS is now increasing because of the ageing of the population. This implies more frequent invasive procedures (mainly vascular) as a consequence of the concomitant disease. Nonetheless, the mortality associated with LNVE due to CoNS does not seem to be

  3. A 29-Year-Old Harken Disk Mitral Valve

    PubMed Central

    Hsi, David H.; Ryan, Gerald F.; Taft, Janice; Arnone, Thomas J.

    2003-01-01

    An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patient's 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features. (Tex Heart Inst J 2003;30:319–21) PMID:14677746

  4. Disturbances of Pulmonary Function in Mitral Valve Disease

    PubMed Central

    Palmer, Wilfred H.; Gee, J. B. L.; Mills, F. C.; Bates, D. V.

    1963-01-01

    To study the sequence of changes in respiratory function that occur in the natural history of mitral stenosis, and the physiological basis of “cardiac dyspnea”, 30 patients with chronic mitral valve disease were subjected to detailed pulmonary function tests. There was no significant change in vital capacity and functional residual capacity. The reduction in maximal mid-expiratory flow rate showed excellent correlation with the respiratory symptoms. The pulmonary capillary blood volume was increased in moderately advanced cases but was consistently reduced in the severest cases. Hyperventilation was due to an increased respiratory rate. Dyspnea was associated with increased respiratory work owing to the interrelation between the reduction in diffusion capacity, compliance, cardiac output, the increase in airway resistance, and the uneven ventilation and perfusion of the lungs. The amount of “effort” required to breathe is incommensurate with the external load in these patients. PMID:14060164

  5. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    PubMed

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  6. System and method for controlling hydraulic pressure in electro-hydraulic valve actuation systems

    DOEpatents

    Brennan, Daniel G; Marriott, Craig D; Cowgill, Joel; Wiles, Matthew A; Patton, Kenneth James

    2014-09-23

    A control system for an engine includes a first lift control module and a second lift control module. The first lift control module increases lift of M valves of the engine to a predetermined valve lift during a period before disabling or re-enabling N valves of the engine. The second lift control module decreases the lift of the M valves to a desired valve lift during a period after enabling or re-enabling the N valves of the engine, wherein N and M are integers greater than or equal to one.

  7. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    PubMed

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  8. Diagnostic for two-mode variable valve activation device

    DOEpatents

    Fedewa, Andrew M

    2014-01-07

    A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.

  9. The challenge of valve-in-valve procedures in degenerated Mitroflow bioprostheses and the advantage of using the JenaValve transcatheter heart valve.

    PubMed

    Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik

    2014-12-01

    Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.

  10. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    PubMed

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

    PubMed Central

    Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin

    2015-01-01

    Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380

  12. Early Identification of Aortic Valve Sclerosis Using Iron Oxide Enhanced MRI

    PubMed Central

    Hamilton, Amanda M.; Rogers, Kem A.; Belisle, Andre J.L.; Ronald, John A.; Rutt, Brian K.; Weissleder, Ralph; Boughner, Derek R.

    2017-01-01

    Purpose To test the ability of MION-47 enhanced MRI to identify tissue macrophage infiltration in a rabbit model of aortic valve sclerosis (AVS). Materials and Methods The aortic valves of control and cholesterol-fed New Zealand White rabbits were imaged in vivo pre- and 48 h post-intravenous administration of MION-47 using a 1.5 Tesla (T) MR clinical scanner and a CINE fSPGR sequence. MION-47 aortic valve cusps were imaged ex vivo on a 3.0T whole-body MR system with a custom gradient insert coil and a three-dimensional (3D) FIESTA sequence and compared with aortic valve cusps from control and cholesterol-fed contrast-free rabbits. Histopathological analysis was performed to determine the site of iron oxide uptake. Results MION-47 enhanced the visibility of both control and cholesterol-fed rabbit valves in in vivo images. Ex vivo image analysis confirmed the presence of significant signal voids in contrast-administered aortic valves. Signal voids were not observed in contrast-free valve cusps. In MION-47 administered rabbits, histopathological analysis revealed iron staining not only in fibrosal macrophages of cholesterol-fed valves but also in myofibroblasts from control and cholesterol-fed valves. Conclusion Although iron oxide labeling of macrophage infiltration in AVS has the potential to detect the disease process early, a macrophage-specific iron compound rather than passive targeting may be required. PMID:20027578

  13. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    PubMed

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  14. Echocardiographic Assessment of Heart Valve Prostheses

    PubMed Central

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  15. Hemodynamics of physiological blood flow in the aorta with nonlinear anisotropic heart valve

    NASA Astrophysics Data System (ADS)

    Sotiropoulos, Fotis; Gilmanov, Anvar; Stolarski, Henryk

    2016-11-01

    The hemodynamic blood flow in cardiovascular system is one of the most important factor, which causing several vascular diseases. We developed a new Curvilinear Immersed Boundary - Finite Element - Fluid Structure Interaction (CURVIB-FE-FSI) method to analyze hemodynamic of pulsatile blood flow in a real aorta with nonlinear anisotropic aortic valve at physiological conditions. Hyperelastic material model, which is more realistic for describing heart valve have been incorporated in the CURVIB-FE-FSI code to simulate interaction of aortic heart valve with pulsatile blood flow. Comparative studies of hemodynamics for linear and nonlinear models of heart valve show drastic differences in blood flow patterns and hence differences of stresses causing impact at leaflets and aortic wall. This work is supported by the Lillehei Heart Institute at the University of Minnesota.

  16. Tricuspid regurgitation after successful mitral valve surgery

    PubMed Central

    Katsi, Vasiliki; Raftopoulos, Leonidas; Aggeli, Constantina; Vlasseros, Ioannis; Felekos, Ioannis; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Kallikazaros, Ioannis

    2012-01-01

    The tricuspid valve (TV) is inseparably connected with the mitral valve (MV) in terms of function. Any pathophysiological condition concerning the MV is potentially a threat for the normal function of the TV as well. One of the most challenging cases is functional tricuspid regurgitation (TR) after surgical MV correction. In the past, TR was considered to progressively revert with time after left-sided valve restoration. Nevertheless, more recent studies showed that TR could develop and evolve postoperatively over time, as well as being closely associated with a poorer prognosis in terms of morbidity and mortality. Pressure and volume overload are usually the underlying pathophysiological mechanisms; structural alterations, like tricuspid annulus dilatation, increased leaflet tethering and right ventricular remodelling are almost always present when regurgitation develops. The most important risk factors associated with a higher probability of late TR development involve the elderly, female gender, larger left atrial size, atrial fibrillation, right chamber dilatation, higher pulmonary artery systolic pressures, longer times from the onset of MV disease to surgery, history of rheumatic heart disease, ischaemic heart disease and prosthetic valve malfunction. The time of TR manifestation can be up to 10 years or more after an MV surgery. Echocardiography, including the novel 3D Echo techniques, is crucial in the early diagnosis and prognosis of future TV disease development. Appropriate surgical technique and timing still need to be clarified. PMID:22457188

  17. C-reactive protein in degenerative aortic valve stenosis

    PubMed Central

    Sanchez, Pedro L; Mazzone, AnnaMaria

    2006-01-01

    Degenerative aortic valve stenosis includes a range of disorder severity from mild leaflet thickening without valve obstruction, "aortic sclerosis", to severe calcified aortic stenosis. It is a slowly progressive active process of valve modification similar to atherosclerosis for cardiovascular risk factors, lipoprotein deposition, chronic inflammation, and calcification. Systemic signs of inflammation, as wall and serum C-reactive protein, similar to those found in atherosclerosis, are present in patients with degenerative aortic valve stenosis and may be expression of a common disease, useful in monitoring of stenosis progression. PMID:16774687

  18. A thin film nitinol heart valve.

    PubMed

    Stepan, Lenka L; Levi, Daniel S; Carman, Gregory P

    2005-11-01

    In order to create a less thrombogenic heart valve with improved longevity, a prosthetic heart valve was developed using thin film nitinol (NiTi). A "butterfly" valve was constructed using a single, elliptical piece of thin film NiTi and a scaffold made from Teflon tubing and NiTi wire. Flow tests and pressure readings across the valve were performed in vitro in a pulsatile flow loop. Bio-corrosion experiments were conducted on untreated and passivated thin film nitinol. To determine the material's in vivo biocompatibility, thin film nitinol was implanted in pigs using stents covered with thin film NiTi. Flow rates and pressure tracings across the valve were comparable to those through a commercially available 19 mm Perimount Edwards tissue valve. No signs of corrosion were present on thin film nitinol samples after immersion in Hank's solution for one month. Finally, organ and tissue samples explanted from four pigs at 2, 3, 4, and 6 weeks after thin film NiTi implantation appeared without disease, and the thin film nitinol itself was without thrombus formation. Although long term testing is still necessary, thin film NiTi may be very well suited for use in artificial heart valves.

  19. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  20. Redo aortic valve surgery versus transcatheter valve-in-valve implantation for failing surgical bioprosthetic valves: consecutive patients in a single-center setting

    PubMed Central

    Wottke, Michael; Deutsch, Marcus-André; Krane, Markus; Piazza, Nicolo; Lange, Ruediger; Bleiziffer, Sabine

    2015-01-01

    Background Due to a considerable rise in bioprosthetic as opposed to mechanical valve implantations, an increase of patients presenting with failing bioprosthetic surgical valves in need of a reoperation is to be expected. Redo surgery may pose a high-risk procedure. Transcatheter aortic valve-in-valve implantation is an innovative, less-invasive treatment alternative for these patients. However, a comprehensive evaluation of the outcome of consecutive patients after a valve-in-valve TAVI [transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV)] as compared to a standard reoperation [surgical aortic valve redo-operation (SAV-in-SAV)] has not yet been performed. The goal of this study was to compare postoperative outcomes after TAV-in-SAV and SAV-in-SAV in a single center setting. Methods All SAV-in-SAV and TAV-in-SAV patients from January 2001 to October 2014 were retrospectively reviewed. Patients with previous mechanical or transcatheter valves, active endocarditis and concomitant cardiac procedures were excluded. Patient characteristics, preoperative data, post-procedural complications, and 30-day mortality were collected from a designated database. Mean values ± SD were calculated for all continuous variables. Counts and percentages were calculated for categorical variables. The Chi-square and Fisher exact tests were used to compare categorical variables. Continuous variables were compared using the t-test for independent samples. A 2-sided P value <0.05 was considered statistically significant. Results A total of 102 patients fulfilled the inclusion criteria, 50 patients (49%) underwent a transcatheter valve-in-valve procedure, while 52 patients (51%) underwent redo-surgery. Patients in the TAV-in-SAV group were significantly older, had a higher mean logistic EuroSCORE and exhibited a lower mean left ventricular ejection fraction than patients in the SAV-in-SAV group (78.1±6.7 vs. 66.2±13.1, P<0.001; 27.4±18.7 vs. 14.4±10, P<0.001; and 49.8±13

  1. MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.

    PubMed

    Kistan, D; Booysen, M; Alexander, G; Madiba, T E

    2017-06-01

    Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients

  2. [Valvular heart disease associated with coronary artery disease].

    PubMed

    Yildirir, Aylin

    2009-07-01

    Nowadays, age-related degenerative etiologies have largely replaced the rheumatic ones and as a natural result of this etiologic change, coronary artery disease has become associated with valvular heart disease to a greater extent. Degenerative aortic valve disease has an important pathophysiological similarity to atherosclerosis and is the leader in this association. There is a general consensus that severely stenotic aortic valve should be replaced during bypass surgery for severe coronary artery disease. For moderate degree aortic stenosis, aortic valve replacement is usually performed during coronary bypass surgery. Ischemic mitral regurgitation has recently received great attention from both diagnostic and therapeutic points of view. Ischemic mitral regurgitation significantly alters the prognosis of the patient with coronary artery disease. Severe ischemic mitral regurgitation should be corrected during coronary bypass surgery and mitral valve repair should be preferred to valve replacement. For moderate degree ischemic mitral regurgitation, many authors prefer valve surgery with coronary bypass surgery. In this review, the main characteristics of patients with coronary artery disease accompanying valvular heart disease and the therapeutic options based on individual valve pathology are discussed.

  3. Reoperations after tricuspid valve repair: re-repair versus replacement

    PubMed Central

    Hwang, Ho Young; Kim, Kyung-Hwan; Kim, Ki-Bong

    2016-01-01

    Background Data demonstrating results of reoperation after initial tricuspid valve repair are scarce. We evaluated outcomes of tricuspid reoperations after tricuspid valve repair and compared the results of tricuspid re-repair with those of tricuspid valve replacement (TVR). Methods From 1994 to 2012, 53 patients (56±15 years, male:female =14:39) underwent tricuspid reoperations due to recurrent tricuspid regurgitation (TR) after initial repair. Twenty-two patients underwent tricuspid re-repair (TAP group) and 31 patients underwent TVR (TVR group). Results Early mortality occurred in 6 patients (11%). Early mortality and incidence of postoperative complications were similar between the 2 groups. There were 14 cases of late mortality including 9 cardiac deaths. Five- and 10-year free from cardiac death rates were 82% and 67%, respectively, without any intergroup difference. Recurrent TR (> moderate) developed in 6 TAP group patients and structural valve deterioration occurred in 1 TVR group patient (P=0.002). Isolated tricuspid valve surgery (P=0.044) and presence of atrial fibrillation during the follow-up (P=0.051) were associated with recurrent TR after re-repair. However, the overall tricuspid valve-related event rates were similar between the 2 groups with 5- and 10-year rates of 61% and 41%, respectively. Conclusions Tricuspid valve reoperation after initial repair resulted in high rates of operative mortality and complications. Long-term event-free rate was similar regardless of the type of surgery. However, great care might be needed when performing re-repair in patients with atrial fibrillation and those who had isolated tricuspid valve disease due to high recurrence of TR after re-repair. PMID:26904221

  4. Echocardiographic predictors of survival in dogs with myxomatous mitral valve disease.

    PubMed

    Sargent, Julia; Muzzi, Ruthnea; Mukherjee, Rajat; Somarathne, Sharlene; Schranz, Katherine; Stephenson, Hannah; Connolly, David; Brodbelt, David; Fuentes, Virginia Luis

    2015-03-01

    To evaluate vena contracta and other echocardiographic measures of myxomatous mitral valve disease (MMVD) severity in a multivariable analysis of survival in dogs. 70 dogs diagnosed with MMVD from stored echocardiographic images that met study inclusion criteria. Left heart dimensions were measured as well as mitral regurgitant jet area/left atrial area (JAR), early mitral filling velocity (Evel), extent of mitral valve prolapse in right and left views (ProlR, ProlL), Prol indexed to aortic diameter (ProlR:Ao, ProlL:Ao), presence of a flail leaflet (FlailR, FlailL), and mitral regurgitation vena contracta diameter (VCR, VCL) indexed to aortic diameter (VCR:Ao, VCL:Ao). Follow-up from referring veterinarians was obtained by questionnaire or telephone to determine survival times. Inter- and intra-observer agreement was evaluated with Bland-Altman plots and weighted Kappa analysis. Survival was analyzed using Kaplan-Meier curves, logrank tests and Cox's proportional hazards. Logrank analysis showed VCL:Ao, VCR:Ao, FlailL, ProlR:Ao, ProlL:Ao, left ventricular internal dimension in diastole indexed to aortic diameter (LVIDD:Ao) >2.87, left atrium to aorta ratio (LA/Ao) >1.6, and Evel >1.4 m/s were predictors of cardiac mortality. In a multivariable analysis, the independent predictors of cardiac mortality were Evel >1.4 m/s [hazard ratio (HR) 5.0, 95% confidence interval (CI) 2.5-10.3], FlailL (HR 3.1, 95% CI 1.3-7.9), and ProlR:Ao (HR 2.8, 95% CI 1.3-6.3). Echocardiographic measures of mitral regurgitation severity and mitral valve pathology provide valuable prognostic information independent of chamber enlargement in dogs with MMVD. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Aortic valve ochronosis: a rare manifestation of alkaptonuria

    PubMed Central

    Steger, Christina Maria

    2011-01-01

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed. PMID:22689837

  6. Aortic valve ochronosis: a rare manifestation of alkaptonuria.

    PubMed

    Steger, Christina Maria

    2011-07-28

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.

  7. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    PubMed

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  8. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    PubMed

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  9. Combined PCI and minimally invasive heart valve surgery for high-risk patients.

    PubMed

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Zhao, David X; Byrne, John G

    2009-12-01

    Combined coronary artery valvular heart disease is a major cause of morbidity and mortality in the adult patient population. The standard treatment for such disease has been open heart surgery in which coronary artery bypass grafting (CABG) is performed concurrently with valve surgery using a median sternotomy and cardiopulmonary bypass. With the increasing complexity of patients referred to surgery, some patients may prove to be poor surgical candidates for combined valve and CABG surgery. In certain selected patients who fall into this category, valve surgery and percutaneous coronary intervention (PCI) have been considered a feasible alternative. Conventionally, valve surgery is performed in the cardiac surgical operating room, whereas PCI is carried out in the cardiac catheterization laboratory. Separation of these two procedural suites has presented a logistic limitation because it impedes the concomitant performance of both procedures in one setting. Hence, PCI and valve surgery usually have been performed as a "two-stage" procedure in two different operative suites, with the procedures being separated by hours, days, or weeks. Technologic advancements have made possible the construction of a "hybrid" procedural suite that combines the facilities of a cardiac surgical operating room with those of a cardiac catheterization laboratory. This design has enabled the concept of "one-stage" or "one-stop" PCI and valve surgery, allowing both procedures to be performed in a hybrid suite in one setting, separated by minutes. The advantages of such a method could prove to be multifold by enabling a less invasive surgical approach and improving logistics, patient satisfaction, and outcomes in selected patients.

  10. Semi-automation of Doppler Spectrum Image Analysis for Grading Aortic Valve Stenosis Severity.

    PubMed

    Niakšu, O; Balčiunaitė, G; Kizlaitis, R J; Treigys, P

    2016-01-01

    Doppler echocardiography analysis has become a golden standard in the modern diagnosis of heart diseases. In this paper, we propose a set of techniques for semi-automated parameter extraction for aortic valve stenosis severity grading. The main objectives of the study is to create echocardiography image processing techniques, which minimize manual image processing work of clinicians and leads to reduced human error rates. Aortic valve and left ventricle output tract spectrogram images have been processed and analyzed. A novel method was developed to trace systoles and to extract diagnostic relevant features. The results of the introduced method have been compared to the findings of the participating cardiologists. The experimental results showed the accuracy of the proposed method is comparable to the manual measurement performed by medical professionals. Linear regression analysis of the calculated parameters and the measurements manually obtained by the cardiologists resulted in the strongly correlated values: peak systolic velocity's and mean pressure gradient's R2 both equal to 0.99, their means' differences equal to 0.02 m/s and 4.09 mmHg, respectively, and aortic valve area's R2 of 0.89 with the two methods means' difference of 0.19 mm. The introduced Doppler echocardiography images processing method can be used as a computer-aided assistance in the aortic valve stenosis diagnostics. In our future work, we intend to improve precision of left ventricular outflow tract spectrogram measurements and apply data mining methods to propose a clinical decision support system for diagnosing aortic valve stenosis.

  11. Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure.

    PubMed

    D'Amore, Antonio; Luketich, Samuel K; Raffa, Giuseppe M; Olia, Salim; Menallo, Giorgio; Mazzola, Antonino; D'Accardi, Flavio; Grunberg, Tamir; Gu, Xinzhu; Pilato, Michele; Kameneva, Marina V; Badhwar, Vinay; Wagner, William R

    2018-01-01

    Valvular heart disease is currently treated with mechanical valves, which benefit from longevity, but are burdened by chronic anticoagulation therapy, or with bioprosthetic valves, which have reduced thromboembolic risk, but limited durability. Tissue engineered heart valves have been proposed to resolve these issues by implanting a scaffold that is replaced by endogenous growth, leaving autologous, functional leaflets that would putatively eliminate the need for anticoagulation and avoid calcification. Despite the diversity in fabrication strategies and encouraging results in large animal models, control over engineered valve structure-function remains at best partial. This study aimed to overcome these limitations by introducing double component deposition (DCD), an electrodeposition technique that employs multi-phase electrodes to dictate valve macro and microstructure and resultant function. Results in this report demonstrate the capacity of the DCD method to simultaneously control scaffold macro-scale morphology, mechanics and microstructure while producing fully assembled stent-less multi-leaflet valves composed of microscopic fibers. DCD engineered valve characterization included: leaflet thickness, biaxial properties, bending properties, and quantitative structural analysis of multi-photon and scanning electron micrographs. Quasi-static ex-vivo valve coaptation testing and dynamic organ level functional assessment in a pressure pulse duplicating device demonstrated appropriate acute valve functionality. Copyright © 2017. Published by Elsevier Ltd.

  12. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    PubMed

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p < 0.001). Thoracic aortic aneurysms were significantly more likely to be diagnosed in late follow-up in patients with Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p < 0.001). Patients with Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p < 0.001). The much higher long-term rates of aortic complications after AVR observed in patients with Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities

  13. [Tricuspid valve regurgitation : Indications and operative techniques].

    PubMed

    Lange, R; Piazza, N; Günther, T

    2017-11-01

    Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.

  14. Tricuspid valve replacement with mechanical prostheses: Short and long-term outcomes.

    PubMed

    Rossello, Xavier; Muñoz-Guijosa, Christian; Mena, Elisabet; Camprecios, Marta; Mendez, Ana B; Borras, Xavier; Padro, Josep M

    2017-09-01

    Tricuspid valve replacement has been associated with high mortality and poor long-term outcomes. We report the preoperative risk factors associated with short and long-term outcomes following tricuspid valve replacement with mechanical prostheses. In 62 patients who underwent mechanical tricuspid valve replacement, clinical, laboratory, and echocardiographic findings were analyzed using both univariate and multivariate analyses to describe operative and long-term mortality. In our population (mean age 59 ± 9.7 years, 82.3% female), most common causes of tricuspid valve disease were rheumatic fever (69.4%) and functional regurgitation (19.4%). Operative and long-term mortality were 17.7 and 33.9%, respectively. Age, diabetes mellitus, and coronary artery disease were independently associated with increased long-term mortality. New York Heart Association (NYHA) class and right heart failure symptoms significantly improved during follow-up. In this series of mechanical tricuspid valve replacements in patients with predominately rheumatic heart disease, operative and long-term mortality were increased; however, survivors had significant improvement in their NYHA class and freedom from right heart failure symptoms. Three preoperative factors (age, diabetes mellitus, and coronary artery disease) were independently associated with long-term mortality. © 2017 Wiley Periodicals, Inc.

  15. Percutaneous Dual-valve Intervention in a High-risk Patient with Severe Aortic and Mitral Stenosis

    PubMed Central

    Mrevlje, Blaz; Aboukura, Mohamad; Nienaber, Christoph A.

    2016-01-01

    Aortic stenosis is the most frequent and mitral stenosis is the least frequent native single-sided valve disease in Europe. Patients with the combination of severe symptomatic degenerative aortic and mitral stenosis are very rare. Guidelines for the treatment of heart valve diseases are clear for single-valve situations. However, there is no common agreement or recommendation for the best treatment strategy in patients with multiple valve disease and severe concomitant comorbidities. A 76-year-old female patient with the combination of severe degenerative symptomatic aortic and mitral stenosis and several comorbidities including severe obesity, who was found unsuitable surgical candidate by the heart team and unsuitable for two-time general anesthesia in the case of two-step single-valve percutaneous approach by anesthesiologists, underwent successful percutaneous dual-valve single-intervention (transcatheter aortic valve implantation and percutaneous mitral balloon commissurotomy). Percutaneous dual-valve single-intervention is feasible in selected symptomatic high-risk patients. PMID:27867460

  16. Check valve

    DOEpatents

    Upton, Hubert Allen; Garcia, Pablo

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

  17. Check valve

    DOEpatents

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  18. Afterload mismatch in aortic and mitral valve disease: implications for surgical therapy.

    PubMed

    Ross, J

    1985-04-01

    In the management of patients with valvular heart disease, an understanding of the effects of altered loading conditions on the left ventricle is important in reaching a proper decision concerning the timing of corrective operation. In acquired valvular aortic stenosis, concentric hypertrophy generally maintains left ventricular chamber size and ejection fraction within normal limits, but in late stage disease function can deteriorate as preload reserve is lost and aortic stenosis progresses. In this setting, even when the ejection fraction is markedly reduced (less than 25%), it can improve to normal after aortic valve replacement, suggesting that afterload mismatch rather than irreversibly depressed myocardial contractility was responsible for left ventricular failure. Therefore, patients with severe aortic stenosis and symptoms should not be denied operation because of impaired cardiac function. In chronic severe aortic and mitral regurgitation, operation is generally recommended when symptoms are present, but whether to recommend operation to prevent irreversible myocardial damage in patients with few or no symptoms has remained controversial. In aortic regurgitation, left ventricular function generally improves postoperatively, even if it is moderately impaired preoperatively, indicating correction of afterload mismatch. Most such patients can be carefully followed by echocardiography. However, in some patients, severe left ventricular dysfunction fails to improve postoperatively. Therefore, when echocardiographic studies in the patient with severe aortic regurgitation show an ejection fraction of less than 40% (fractional shortening less than 25%) plus enlarging left ventricular end-diastolic diameter (approaching 38 mm/m2 body surface area) and end-systolic diameter (approaching 50 mm or 26 mm/m2), confirmation of these findings by cardiac catheterization and consideration of operation are advisable even in patients with minimal symptoms. In chronic mitral

  19. Evaluation of a transient, simultaneous, arbitrary Lagrange-Euler based multi-physics method for simulating the mitral heart valve.

    PubMed

    Espino, Daniel M; Shepherd, Duncan E T; Hukins, David W L

    2014-01-01

    A transient multi-physics model of the mitral heart valve has been developed, which allows simultaneous calculation of fluid flow and structural deformation. A recently developed contact method has been applied to enable simulation of systole (the stage when blood pressure is elevated within the heart to pump blood to the body). The geometry was simplified to represent the mitral valve within the heart walls in two dimensions. Only the mitral valve undergoes deformation. A moving arbitrary Lagrange-Euler mesh is used to allow true fluid-structure interaction (FSI). The FSI model requires blood flow to induce valve closure by inducing strains in the region of 10-20%. Model predictions were found to be consistent with existing literature and will undergo further development.

  20. Three-dimensional echocardiographic evaluation of an incidental quadricuspid aortic valve.

    PubMed

    Armen, Todd A; Vandse, Rashmi; Bickle, Katherine; Nathan, Nadia

    2008-03-01

    Quadricuspid aortic valve is one of the rare forms of congenital cardiac valvular disease. Its diagnosis is often missed, even with the transthoracic echocardiogram. Many of these patients progress to aortic incompetence later in life requiring surgical intervention. In addition, quadricuspid aortic valve can be associated with other congenital cardiac deformities. Hence early recognition and follow-up is critical in these patients. We report a patient with quadricuspid aortic valve identified on intraoperative transesophageal 3-D echocardiography. This 66-year-old male presented with the features of congestive heart failure. The preoperative transthoracic echocardiogram (TTE) disclosed, moderately severe aortic valve insufficiency along with severe mitral and tricuspid regurgitation, but failed to reveal the quadricuspid anomaly of the aortic valve. Interestingly, this patient had undergone transthoracic echocardiography on two previous occasions during the past seven years for the evaluation of his valvular heart disease, which all failed to document this anomaly. Intraoperatively, transesophageal echocardiography (TEE) displayed an aortic valve composed of three medium and one small cusps. Our patient's case demonstrates the usefulness of transesophageal echocardiography in detection of this uncommon congenital malformation.

  1. Recent progress in heart valve surgery: innovation or evolution?

    PubMed

    Lausberg, H; Schäfers, H J

    2004-08-01

    Although heart valve surgery continues to evolve in a dynamic fashion, there is still no optimal solution for all patients. Minimally invasive surgery currently receives considerable attention but its value still needs to be determined. Progress has been made in valve repair, which now allows reconstruction in most patients with mitral valve disease. Reconstruction of the aortic valve is now also possible with results that are now comparable to those of mitral repair. In the future a wider application of repair procedures and further improvements of biologic valves can be anticipated not only to influence long-term results, but also the decision making process for conservative or surgical treatment.

  2. Left atrium function by 2D speckle tracking in aortic valve disease.

    PubMed

    Salas-Pacheco, Jose L; Ávila-Vanzzini, Nydia; Eugenia, Ruiz-Esparza M; Arias-Godínez, Jose A

    2016-12-01

    A paucity of data exists about left atrium (LA) function in aortic valve stenosis (AS) or regurgitation (AR). Two-dimensional speckle tracking echocardiography allows the noninvasive study of LA functional disturbances in aortic valve disease and their impact in the development of pulmonary hypertension (PH). Consecutive patients with moderate or severe AS or AR were included. Left ventricle (LV) and LA speckle tracking strain quantification was performed. We included 42 patients with AS and 30 with AR. Differences were not found in LA volumes and strain in AS or AR. The LA volumetric derangements parallel the decrease in LA longitudinal strain. Maximum LA volume, minimum LA volume, and indexed LA volume were higher in severe valvular disease (SVD) than in moderate [23 cc (P=.018, IC 95% : 4-41), 16 cc (P=.035, IC 95% : 2-31), and 14 cc (P=.022, IC 95% : 2-25), respectively], occurred in the same way with LA strain in the conduit (6.3%, P=.034, IC 95% : 1-12) and reservoir (7.1%, P=.04, IC 95% : 2-14) phases. In multivariable model, strain of reservoir phase was the variable mainly associated with PH; each decrease in one unit of strain of reservoir phase increased 6% the PH probability (OR: 1.06, P=.01). This study demonstrates that in patients with AS and AR, the LA has a similar behavior and that exist a close correlation between LA volumetric and functional parameters. The variable mainly associated with PH was LA strain of reservoir phase. © 2016, Wiley Periodicals, Inc.

  3. Microfluidic valve array control system integrating a fluid demultiplexer circuit

    NASA Astrophysics Data System (ADS)

    Kawai, Kentaro; Arima, Kenta; Morita, Mizuho; Shoji, Shuichi

    2015-06-01

    This paper proposes an efficient control method for the large-scale integration of microvalves in microfluidic systems. The proposed method can control 2n individual microvalves with 2n + 2 control lines (where n is an integer). The on-chip valves are closed by applying pressure to a control line, similar to conventional pneumatic microvalves. Another control line closes gate valves between the control line to the on-chip valves and the on-chip valves themselves, to preserve the state of the on-chip valves. The remaining control lines select an activated gate valve. While the addressed gate valve is selected by the other control lines, the corresponding on-chip valve is actuated by applying input pressure to the control line to the on-chip valves. Using this method would substantially reduce the number of world-to-chip connectors and off-chip valve controllers. Experiments conducted using a fabricated 28 microvalve array device, comprising 256 individual on-chip valves controlled with 18 (2   ×   8 + 2) control lines, yielded switching speeds for the selected on-chip valve under 90 ms.

  4. Constitutive modeling of jugular vein-derived venous valve leaflet tissues.

    PubMed

    Kaul, Nayyan; Huang, Hsiao-Ying Shadow

    2017-11-01

    Venous valve tissues, though used in vein reconstruction surgeries and bioprosthetic valves with moderate success, have not been extensively studied with respect to their structure. Their inherent anisotropic, non-linear behavior combined with severe diseases which affect veins, such as chronic venous insufficiency, warrant understanding the structure and material behavior of these tissues. Hence, before any bioprosthetic grafts may be used in place of tissues, it is of the utmost importance to understand the mechanical and structural properties of these tissues as this may lead to higher success rates for valve replacement surgeries. The longevity of the bioprosthetics may also increase if the manufactured grafts behave the same as native valves. Building on the scant information about the uniaxial and biaxial mechanical properties of jugular venous valves and wall tissues from previous studies, the current focus of our investigation lies in understanding the material behavior by establishing a phenomenological strain energy-based constitutive relation for the tissues. We used bovine veins to study the behavior of valve leaflet tissue and adjoining wall tissue (from the proximal and distal ends of the veins) under different biaxial testing protocols. We looked at the behavior of numerical partial derivatives of the strain energy to select a suitable functional form for the strain energy for wall and valve tissues. Using this strain energy descriptor, we determined the Cauchy stress and compared it with experimental results under additional sets of displacement-controlled biaxial testing protocols to find material specific model parameters by the Powell's method algorithm. Results show that whereas wall tissue strain energy can be explained using a polynomial non-linear function, the valve tissue, due to higher non-linearities, requires an exponential function. This study may provide useful information for the primary stages of bioprosthetic designs and replacement

  5. Exhaust gas bypass valve control for thermoelectric generator

    DOEpatents

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  6. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    PubMed

    Grams, Samantha Torres; Kimoto, Karen Yumi Mota; Azevedo, Elen Moda de Oliveira; Lança, Marina; Albuquerque, André Luis Pereira de; Brito, Christina May Moran de; Yamaguti, Wellington Pereira

    2015-01-01

    Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. This study aimed to compare the MIP values assessed by standard method (MIPsta) and by unidirectional expiratory valve method (MIPuni) in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated. This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1]) was used to determine intraobserver and interobserver reproducibility. The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O) than the mean values for MIPsta (-102.5 ± 23.9 cmH2O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91), and high correlation for Test 2 (ICC[2,1] = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86) and evaluator B (ICC[2,1] = 0.77). MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  7. Endogenous Reference Genes for Gene Expression Studies on Bicuspid Aortic Valve Associated Aortopathy in Humans.

    PubMed

    Harrison, Oliver J; Moorjani, Narain; Torrens, Christopher; Ohri, Sunil K; Cagampang, Felino R

    2016-01-01

    Bicuspid aortic valve (BAV) disease is the most common congenital cardiac abnormality and predisposes patients to life-threatening aortic complications including aortic aneurysm. Quantitative real-time reverse transcription PCR (qRT-PCR) is one of the most commonly used methods to investigate underlying molecular mechanisms involved in aortopathy. The accuracy of the gene expression data is dependent on normalization by appropriate housekeeping (HK) genes, whose expression should remain constant regardless of aortic valve morphology, aortic diameter and other factors associated with aortopathy. Here, we identified an appropriate set of HK genes to be used as endogenous reference for quantifying gene expression in ascending aortic tissue using a spin column-based RNA extraction method. Ascending aortic biopsies were collected intra-operatively from patients undergoing aortic valve and/or ascending aortic surgery. These patients had BAV or tricuspid aortic valve (TAV), and the aortas were either dilated (≥4.5cm) or undilated. The cohort had an even distribution of gender, valve disease and hypertension. The expression stability of 12 reference genes were investigated (ATP5B, ACTB, B2M, CYC1, EIF4A2, GAPDH, SDHA, RPL13A, TOP1, UBC, YWHAZ, and 18S) using geNorm software. The most stable HK genes were found to be GAPDH, UBC and ACTB. Both GAPDH and UBC demonstrated relative stability regardless of valve morphology, aortic diameter, gender and age. The expression of B2M and SDHA were found to be the least stable HK genes. We propose the use of GAPDH, UBC and ACTB as reference genes for gene expression studies of BAV aortopathy using ascending aortic tissue.

  8. Relation of aortic valve calcium to chronic kidney disease (from the Chronic Renal Insufficiency Cohort Study).

    PubMed

    Guerraty, Marie A; Chai, Boyang; Hsu, Jesse Y; Ojo, Akinlolu O; Gao, Yanlin; Yang, Wei; Keane, Martin G; Budoff, Matthew J; Mohler, Emile R

    2015-05-01

    Although subjects with chronic kidney disease (CKD) are at markedly increased risk for cardiovascular mortality, the relation between CKD and aortic valve calcification has not been fully elucidated. Also, few data are available on the relation of aortic valve calcification and earlier stages of CKD. We sought to assess the relation of aortic valve calcium (AVC) with estimated glomerular filtration rate (eGFR), traditional and novel cardiovascular risk factors, and markers of bone metabolism in the Chronic Renal Insufficiency Cohort (CRIC) Study. All patients who underwent aortic valve scanning in the CRIC study were included. The relation between AVC and eGFR, traditional and novel cardiovascular risk factors, and markers of calcium metabolism were analyzed using both unadjusted and adjusted regression models. A total of 1,964 CRIC participants underwent computed tomography for AVC quantification. Decreased renal function was independently associated with increased levels of AVC (eGFR 47.11, 44.17, and 39 ml/min/1.73 m2, respectively, p<0.001). This association persisted after adjusting for traditional, but not novel, AVC risk factors. Adjusted regression models identified several traditional and novel risk factors for AVC in patients with CKD. There was a difference in AVC risk factors between black and nonblack patients. In conclusion, our study shows that eGFR is associated in a dose-dependent manner with AVC in patients with CKD, and this association is independent of traditional cardiovascular risk factors. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Increased dietary intake of vitamin A promotes aortic valve calcification in vivo.

    PubMed

    Huk, Danielle J; Hammond, Harriet L; Kegechika, Hiroyuki; Lincoln, Joy

    2013-02-01

    Calcific aortic valve disease (CAVD) is a major public health problem with no effective treatment available other than surgery. We previously showed that mature heart valves calcify in response to retinoic acid (RA) treatment through downregulation of the SRY transcription factor Sox9. In this study, we investigated the effects of excess vitamin A and its metabolite RA on heart valve structure and function in vivo and examined the molecular mechanisms of RA signaling during the calcification process in vitro. Using a combination of approaches, we defined calcific aortic valve disease pathogenesis in mice fed 200 IU/g and 20 IU/g of retinyl palmitate for 12 months at molecular, cellular, and functional levels. We show that mice fed excess vitamin A develop aortic valve stenosis and leaflet calcification associated with increased expression of osteogenic genes and decreased expression of cartilaginous markers. Using a pharmacological approach, we show that RA-mediated Sox9 repression and calcification is regulated by classical RA signaling and requires both RA and retinoid X receptors. Our studies demonstrate that excess vitamin A dietary intake promotes heart valve calcification in vivo. Therefore suggesting that hypervitaminosis A could serve as a new risk factor of calcific aortic valve disease in the human population.

  10. Early Outcomes of Sutureless Aortic Valves

    PubMed Central

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-01-01

    Background In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time. PMID:27298793

  11. Research on digital system design of nuclear power valve

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaolong; Li, Yuan; Wang, Tao; Dai, Ye

    2018-04-01

    With the progress of China's nuclear power industry, nuclear power plant valve products is in a period of rapid development, high performance, low cost, short cycle of design requirements for nuclear power valve is proposed, so there is an urgent need for advanced digital design method and integrated design platform to provide technical support. Especially in the background of the nuclear power plant leakage in Japan, it is more practical to improve the design capability and product performance of the nuclear power valve. The finite element numerical analysis is a common and effective method for the development of nuclear power valves. Nuclear power valve has high safety, complexity of valve chamber and nonlinearity of seal joint surface. Therefore, it is urgent to establish accurate prediction models for earthquake prediction and seal failure to meet engineering accuracy and calculation conditions. In this paper, a general method of finite element modeling for nuclear power valve assembly and key components is presented, aiming at revealing the characteristics and rules of finite element modeling of nuclear power valves, and putting forward aprecision control strategy for finite element models for nuclear power valve characteristics analysis.

  12. Use of a Valved-Conduit for Exclusion of the Infected Portion in the Prosthetic Pulmonary Valve Endocarditis

    PubMed Central

    Jung, Joonho; Lee, Cheol Joo; Lim, Sang-Hyun; Choi, Ho; Park, Soo-Jin

    2013-01-01

    A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39℃) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method. PMID:23772409

  13. Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation

    PubMed Central

    Spina, Roberto; Anthony, Chris; Muller, David WM

    2015-01-01

    Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674

  14. Systolic Anterior Motion of the Mitral Valve after Mitral Valve Repair

    PubMed Central

    Sternik, Leonid; Zehr, Kenton J.

    2005-01-01

    Factors predisposing patients to systolic anterior motion of the mitral valve (SAM) with left ventricular outflow tract (LVOT) obstruction after mitral valve repair are the presence of a myxomatous mitral valve with redundant leaflets, a nondilated hyperdynamic left ventricle, and a short distance between the mitral valve coaptation point and the ventricular septum after repair. From December 1999 through March 2000, we used our surgical method in 6 patients with severely myxomatous regurgitant mitral valves who were at risk of developing SAM. Leaflets were markedly redundant in all 6. Left ventricular function was hyperdynamic in 4 patients and normal in 2. Triangular or quadrangular resection of the midportion of the posterior leaflet and posterior band annuloplasty were performed. To prevent SAM and LVOT obstruction, extra, posteriorly directed, mid-posterior-leaflet secondary chordae tendineae, which would otherwise have been resected, were transferred to the underside of the middle of the mid-anterior leaflet with a small piece of associated valve as an anchoring pledget. This kept the redundant anterior leaflet edge, which extended below the coaptation point, away from the LVOT. No post-repair SAM or LVOT obstruction was observed on intraoperative or discharge echocardiography. All patients had no or trivial residual mitral regurgitation. We conclude that extra chordae tendineae, when available, can be used in mitral valve repair to tether the redundant anterior leaflet and thus prevent it from flipping into the LVOT. This will theoretically prevent SAM and LVOT obstruction in patients with risk factors for SAM. PMID:15902821

  15. [LONG TERM FOLLOW-UP OF TRANSCATHETER SELF EXPANDABLE AORTIC VALVE IMPLANTATION].

    PubMed

    Chen, Shmuel; Zenios, Vicky; Gilon, Dan; Planer, David; Beeri, Ronen; Lotan, Chaim; Danenberg, Haim D

    2018-03-01

    Aortic stenosis is the most common significant valvular disease in the western world. These patients are treated operatively unless they are at high operative risk or inoperable. During the last decade an alternative approach has evolved - transcatheter aortic valve implantation (TAVI). This method was shown to be at least as effective and safe as the operative one. However, very little data exists on long term follow-up (5 years and above), especially regarding valve durability and patient survival. To present a long term follow-up on patients who underwent transcutaneous self-expandable aortic valve implantation in our department between the years 2008-2011. In September 2008 the first CoreValve implantation was performed in Israel at Hadassah Medical Center. All records of patients who were transplanted between 9.2008 and 10.2011 were reviewed. The function of the valve early after the procedure was compared to its function at the end of the follow-up period. A total of 38 patients (out of 71) survived at least 54 months, of them, 19 have an echocardiography examination at the end of the follow-up period. In all patients the implanted valve was found to function well at the end of the follow-up period, without significant stenosis or paravalvular leak. In fact, in approximately half of these patients, the degree of paravalvular leak decreased during the follow-up period. On long term (5 years) follow-up of patients who were implanted with the self-expandable aortic valve (CoreValve), no deterioration of the valve was observed. In fact, in approximately half of the patients, a decrease in the severity of the paravalvular leak was demonstrated.

  16. Fast-Acting Valve

    NASA Technical Reports Server (NTRS)

    Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)

    2003-01-01

    A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.

  17. NT-proBNP and exercise capacity in adult patients with congenital heart disease and a prosthetic valve: a multicentre PROSTAVA study.

    PubMed

    Schoonbeek, R C; Pieper, P G; van Slooten, Y J; Freling, H G; Sieswerda, G T; van Dijk, A P J; Jongbloed, M R M; Post, M C; Bouma, B J; Berger, R M F; Ebels, T; van Melle, J P

    2016-11-01

    N-terminal B‑type natriuretic peptide (NT-proBNP) is an important biomarker for the detection of heart failure. Adults with congenital heart disease (ACHD) and a prosthetic heart valve are at risk for heart failure. This study aimed to determine the value of NT-proBNP in ACHD patients with a prosthetic valve and investigate its relationship with cardiac function and exercise capacity. In this multi-centre cross-sectional observational study, data regarding medical history, echocardiography, exercise testing (VO 2 peak) and laboratory blood evaluation (including NT-proBNP) were collected in ACHD patients with a single prosthetic valve (either homografts, heterografts or mechanical valves). A total of 306 ACHD patients with pulmonary valve replacement (PVR, n = 139), aortic valve replacement (n = 141), mitral valve replacement (n = 21) or tricuspid valve replacement (n = 5) were investigated. The majority of patients (77 %) were in NYHA class I or II. Elevated NT-proBNP levels (cut-off ≥125 pg/ml) were found in 50 % of the patients, with the highest levels in patients with mitral valve replacements. In this study population, NT-proBNP levels were associated with gender (p = 0.029) and VO 2 max (p < 0.001). In PVR patients, NT-proBNP levels were associated with lower VO 2 peak, also after adjustment for age, gender and age at valve replacement in a multivariate model (p = 0.015). In patients with ACHD and a prosthetic valve, elevated NT-proBNP levels are frequently observed despite preserved NYHA class. In PVR patients, a higher NT-proBNP level was associated with a lower VO 2 peak. These results may be of importance in the ongoing discussion about the timing of valve replacement in patients with CHD.

  18. Computational Modeling of Blood Flow and Valve Dynamics in Hearts with Hypertrophic Cardiomyopathy

    NASA Astrophysics Data System (ADS)

    Zheng, Xudong; Mittal, Rajat; Abraham, Theodore; Pinheiro, Aurelio

    2010-11-01

    Hypertrophic Cardiomyopathy (HCM) is a cardiovascular disease manifested by the thickening of the ventricular wall and often leads to a partial obstruction to the blood flow out of the left ventricle. HCM is recognized as one of the most common causes of sudden cardiac death in athletes. In a heart with HCM, the hypertrophy usually narrows the blood flow pathway to the aorta and produces a low pressure zone between the mitral valve and the hypertrophy during systole. This low pressure can suck the mitral valve leaflet back and completely block the blood flow into the aorta. In the current study, a sharp interface immersed boundary method flow solver is employed to study the hemodynamics and valve dynamics inside a heart with HCM. The three-dimensional motion and configuration of the left ventricle including mitral valve leaflets and aortic valves are reconstructed based on echo-cardio data sets. The mechanisms of aortic obstruction associated with HCM are investigated. The long term objective of this study is to develop a computational tool to aid in the assessment and surgical management of HCM.

  19. Anesthetic Considerations for Transcatheter Pulmonary Valve Replacement.

    PubMed

    Gregory, Stephen H; Zoller, Jonathan K; Shahanavaz, Shabana; Chilson, Kelly L; Ridley, Clare H

    2018-02-01

    The introduction of transcatheter therapy for valvular heart disease has revolutionized the care of patients with valvular disorders. Pathologic regurgitation or stenosis of the pulmonary valve, right ventricular outflow tract, or a right ventricle-to-pulmonary artery conduit represent emerging indications for transcatheter therapy. To date, minimal literature exists detailing the anesthetic management of patients undergoing transcatheter pulmonary valve replacement. In this review, the pathophysiology and indications for transcatheter pulmonary valve replacement and possible complications unique to this procedure are reviewed. Anesthetic management, including preoperative assessment, intraoperative considerations, and early postoperative monitoring, are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    PubMed Central

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  1. Sickle cell anemia and mitral valve replacement. Case report.

    PubMed

    Bomfim, V; Ribeiro, A; Gouvea, F; Pereira, J; Björk, V

    1989-01-01

    An 8-year-old black boy with sickle cell disease and severe hemolytic anemia crisis (95% hemoglobin S) also had mitral incompetence due to rheumatic valve disease. A 27 mm monostrut Björk-Shiley valve prosthesis was implanted after partial exchange transfusions had reduced the hemoglobin S to less than 40%. High-flow normothermic perfusion was used during extracorporeal circulation, with care taken to avoid hypoxia and acidosis. Postoperative recovery was uneventful.

  2. Early and mid-term results of autograft rescue by Ross reversal: A one-valve disease need not become a two-valve disease.

    PubMed

    Hussain, Syed T; Majdalany, David S; Dunn, Aaron; Stewart, Robert D; Najm, Hani K; Svensson, Lars G; Houghtaling, Penny L; Blackstone, Eugene H; Pettersson, Gösta B

    2018-02-01

    Risk of reoperation and loss of a second native valve are major drawbacks of the Ross operation. Rather than discarding the failed autograft, it can be placed back into the native pulmonary position by "Ross reversal." We review our early and mid-term results with this operation. From 2006 to 2017, 39 patients underwent reoperation for autograft dysfunction. The autograft was successfully rescued in 35 patients: by Ross reversal in 30, David procedure in 4, and autograft repair in 1. Medical records were reviewed for patient characteristics (mean age was 46 ± 13 years, range 18-67 years, and 23 were male), previous operations, indications for reoperation, hospital outcomes, and echocardiographic findings for the 30 patients undergoing successful Ross reversal. Follow-up was 4.1 ± 3.5 years (range 7 months-11 years). Median interval between the original Ross procedure and Ross reversal was 12 years (range 5-19 years). Eight patients also had absolute indications for replacement of the pulmonary allograft. There was no operative mortality. One patient required reoperation for bleeding. Another had an abdominal aorta injury from use of an endoballoon clamp. There was no other major postoperative morbidity, and median postoperative hospital stay was 7.2 days (range 4-41 days). No patient required reoperation during follow-up. Twenty-four patients had acceptable pulmonary valve function, and 6 had clinically well-tolerated moderate or severe pulmonary regurgitation. Ross reversal can be performed with low morbidity and acceptable pulmonary valve function, reducing patient risk of losing 2 native valves when the autograft fails in the aortic position. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. Porcine Tricuspid Valve Anatomy and Human Compatibility: Relevance for Preclinical Validation of Novel Valve Interventions.

    PubMed

    Waziri, Farhad; Lyager Nielsen, Sten; Michael Hasenkam, John

    2016-09-01

    Tricuspid regurgitation may be a precursor for heart failure, reduced functional capacity, and poor survival. A human compatible experimental model is required to understand the pathophysiology of the tricuspid valve disease as a basis for validating novel tricuspid valve interventions before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin-fixed porcine hearts obtained from Danish Landrace pigs (body weight 80 kg). All valvular dimensions were compared with human data acquired from literature sources. No difference was seen in the tricuspid annulus circumference between porcine and human hearts (13.0 ± 1.2 cm versus 13.5 ± 1.5 cm; p = NS), or in valve area (5.7 ± 1.6 cm2 versus 5.6 ± 1.0 cm2; p = NS). The majority of chordae types exhibited a larger chordal length and thickness in human hearts compared to porcine hearts. In both species, the anterior papillary muscle (PM) was larger than other PMs in the right ventricle, but muscle length varied greatly (range: 5.2-40.3 mm) and was significantly different in pigs and in humans (12.2 ± 3.2 mm versus 19.2 mm; p <0.001). The porcine tricuspid valve was determined to be a valid model for preclinical animal studies, despite various anatomic differences being noted between porcine and human hearts.

  4. Secreted Klotho Attenuates Inflammation-Associated Aortic Valve Fibrosis in Senescence-Accelerated Mice P1.

    PubMed

    Chen, Jianglei; Fan, Jun; Wang, Shirley; Sun, Zhongjie

    2018-05-01

    Senescence-accelerated mice P1 (SAMP1) is an aging model characterized by shortened lifespan and early signs of senescence. Klotho is an aging-suppressor gene. The purpose of this study is to investigate whether in vivo expression of secreted klotho ( Skl ) gene attenuates aortic valve fibrosis in SAMP1 mice. SAMP1 mice and age-matched (AKR/J) control mice were used. SAMP1 mice developed obvious fibrosis in aortic valves, namely fibrotic aortic valve disease. Serum level of Skl was decreased drastically in SAMP1 mice. Expression of MCP-1 (monocyte chemoattractant protein 1), ICAM-1 (intercellular adhesion molecule 1), F4/80, and CD68 was increased in aortic valves of SAMP1 mice, indicating inflammation. An increase in expression of α-smooth muscle actin (myofibroblast marker), transforming growth factorβ-1, and scleraxis (a transcription factor of collagen synthesis) was also found in aortic valves of SAMP1 mice, suggesting that accelerated aging is associated with myofibroblast transition and collagen gene activation. We constructed adeno-associated virus 2 carrying mouse Skl cDNA for in vivo expression of Skl. Skl gene delivery effectively increased serum Skl of SAMP1 mice to the control level. Skl gene delivery inhibited inflammation and myofibroblastic transition in aortic valves and attenuated fibrotic aortic valve disease in SAMP1 mice. It is concluded that senescence-related fibrotic aortic valve disease in SAMP1 mice is associated with a decrease in serum klotho leading to inflammation, including macrophage infiltration and transforming growth factorβ-1/scleraxis-driven myofibroblast differentiation in aortic valves. Restoration of serum Skl levels by adeno-associated virus 2 carrying mouse Skl cDNA effectively suppresses inflammation and myofibroblastic transition and attenuates aortic valve fibrosis. Skl may be a potential therapeutic target for fibrotic aortic valve disease. © 2018 American Heart Association, Inc.

  5. Reoperation for non-structural valvular dysfunction caused by pannus ingrowth in aortic valve prosthesis.

    PubMed

    Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk

    2013-07-01

    The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.

  6. Mitral valve reconstruction in Barlow disease: long-term echographic results and implications for surgical management.

    PubMed

    Jouan, Jérôme; Berrebi, Alain; Chauvaud, Sylvain; Menasché, Philippe; Carpentier, Alain; Fabiani, Jean-Noël

    2012-04-01

    Owing to the complexity of the underlying lesions, Barlow disease remains a challenge for surgeons performing mitral valve repair. We aimed to assess whether our most recent results involving several surgeons were comparable with those of a previous experience in which mitral valve repair was performed by a more limited group of surgeons. From September 2000 to January 2007, 200 patients with Barlow disease (135 men and 65 women; mean age, 56 ± 13 years) were referred to our institution for surgical treatment of their mitral regurgitation. We retrospectively analysed the mitral lesions characteristics, the surgical techniques used, and clinical outcomes. Follow-up echocardiograms were biannually reviewed. Lesions comprised annular dilatation, excess tissue, and leaflet prolapse in all cases. The most frequent prolapsed segments were P2 (88.5%; n = 177) and A2 (55.5%; n = 111). Annular calcifications and restrictive valvular motion were associated in 20% (n = 40). Repair was feasible in 94.7% (n = 179/189) of non-redo interventions. Immediate postoperative echocardiography showed residual mitral regurgitation greater than 1+ in 6 cases; these patients were all reoperated on within the next months. Operative mortality was 1.5% (n = 3). Mean follow-up was 77.5 ± 25.6 months. At 8 years postoperatively, overall survival was 88.6% ± 3.1%, freedom from reintervention was 95.3% ± 1.7%, and freedom from late recurrent moderate mitral regurgitation (>2+) was 90.2% ± 3.1% Provided that the fundamental principles of mitral valve reconstruction are respected, the surgical techniques are highly reproducible with good long-term results, similar to those published during the pioneering phase of this surgery. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  7. Living nano-micro fibrous woven fabric/hydrogel composite scaffolds for heart valve engineering.

    PubMed

    Wu, Shaohua; Duan, Bin; Qin, Xiaohong; Butcher, Jonathan T

    2017-03-15

    Regeneration and repair of injured or diseased heart valves remains a clinical challenge. Tissue engineering provides a promising treatment approach to facilitate living heart valve repair and regeneration. Three-dimensional (3D) biomimetic scaffolds that possess heterogeneous and anisotropic features that approximate those of native heart valve tissue are beneficial to the successful in vitro development of tissue engineered heart valves (TEHV). Here we report the development and characterization of a novel composite scaffold consisting of nano- and micro-scale fibrous woven fabrics and 3D hydrogels by using textile techniques combined with bioactive hydrogel formation. Embedded nano-micro fibrous scaffolds within hydrogel enhanced mechanical strength and physical structural anisotropy of the composite scaffold (similar to native aortic valve leaflets) and also reduced its compaction. We determined that the composite scaffolds supported the growth of human aortic valve interstitial cells (HAVIC), balanced the remodeling of heart valve ECM against shrinkage, and maintained better physiological fibroblastic phenotype in both normal and diseased HAVIC over single materials. These fabricated composite scaffolds enable the engineering of a living heart valve graft with improved anisotropic structure and tissue biomechanics important for maintaining valve cell phenotypes. Heart valve-related disease is an important clinical problem, with over 300,000 surgical repairs performed annually. Tissue engineering offers a promising strategy for heart valve repair and regeneration. In this study, we developed and tissue engineered living nano-micro fibrous woven fabric/hydrogel composite scaffolds by using textile technique combined with bioactive hydrogel formation. The novelty of our technique is that the composite scaffolds can mimic physical structure anisotropy and the mechanical strength of natural aortic valve leaflet. Moreover, the composite scaffolds prevented the

  8. Understanding Lymphatic Valve Function via Computational Modeling

    NASA Astrophysics Data System (ADS)

    Wolf, Ki; Nepiyushchikh, Zhanna; Razavi, Mohammad; Dixon, Brandon; Alexeev, Alexander

    2017-11-01

    The lymphatic system is a crucial part to the circulatory system with many important functions, such as transport of interstitial fluid, fatty acid, and immune cells. Lymphatic vessels' contractile walls and valves allow lymph flow against adverse pressure gradients and prevent back flow. Yet, the effect of lymphatic valves' geometric and mechanical properties to pumping performance and lymphatic dysfunctions like lymphedema is not well understood. Our coupled fluid-solid computational model based on lattice Boltzmann model and lattice spring model investigates the dynamics and effectiveness of lymphatic valves in resistance minimization, backflow prevention, and viscoelastic response under different geometric and mechanical properties, suggesting the range of lymphatic valve parameters with effective pumping performance. Our model also provides more physiologically relevant relations of the valve response under varied conditions to a lumped parameter model of the lymphatic system giving an integrative insight into lymphatic system performance, including its failure due to diseases. NSF CMMI-1635133.

  9. Differentiating the aging of the mitral valve from human and canine myxomatous degeneration

    PubMed Central

    Connell, Patrick S.; Han, Richard I.; Grande-Allen, K. Jane

    2012-01-01

    During the course of both canine and human aging, the mitral valve remodels in generally predictable ways. The connection between these aging changes and the morbidity and mortality that accompany pathologic conditions has not been made clear. By exploring work that has investigated the specific valvular changes in both age and disease, with respect to the cells and the extracellular matrix found within the mitral valve, heretofore unexplored connections between age and myxomatous valve disease can be found. This review addresses several studies that have been conducted to explore such age and disease related changes in extracellular matrix, valvular endothelial and interstitial cells, and valve innervation, and also reviews attempts to correlate aging and myxomatous disease. Such connections can highlight avenues for future research and help provide insight as to when an individual diverts from an aging pattern into a diseased pathway. Recognizing these patterns and opportunities could result in earlier intervention and the hope of reduced morbidity and mortality for patients. PMID:22364720

  10. Elective removal of convexo-concave Björk-Shiley valves.

    PubMed

    Rajesh, P B; Smith, G H; Lawford, P V; Black, M M

    1994-08-01

    Replacement has been an accepted method for treating advanced cardiac valvular disease for more than 25 years. However, the perfect prosthesis has yet to be developed, judging by the number of devices available. A prosthesis that initially appears promising may cause problems in due course, and indeed some devices have been modified or withdrawn from clinical use. A notable example of a prosthetic valve that has give problems is the Björk-Shiley convexo-concave prosthesis, some models of which have undergone mechanical failure due to strut fracture. We report the elective removal of such a valve and the subsequent examination of the prosthesis. The results of this examination suggest that a policy of elective removal is justified.

  11. Late outcome analysis of the Braile Biomédica® pericardial valve in the aortic position

    PubMed Central

    Azeredo, Lisandro Gonçalves; Veronese, Elinthon Tavares; Santiago, José Augusto Duncan; Brandão, Carlos Manuel de Almeida; Pomerantzeff, Pablo Maria Alberto; Jatene, Fabio Biscegli

    2014-01-01

    Objective Aortic valve replacement with Braile bovine pericardial prosthesis has been routinely done at the Heart Institute of the Universidade de São Paulo Medical School since 2006. The objective of this study is to analyze the results of Braile Biomédica® aortic bioprosthesis in patients with aortic valve disease. Methods We retrospectively evaluated 196 patients with aortic valve disease submitted to aortic valve replacement with Braile Biomédica® bovine pericardial prosthesis, between 2006 and 2010. Mean age was 59.41±16.34 years and 67.3% were male. Before surgery, 73.4% of patients were in NYHA functional class III or IV. Results Hospital mortality was 8.16% (16 patients). Linearized rates of mortality, endocarditis, reintervention, and structural dysfunction were 1.065%, 0.91%, 0.68% and 0.075% patients/year, respectively. Actuarial survival was 90.59±2.56% in 88 months. Freedom from reintervention, endocarditis and structural dysfunction was respectively 91.38±2.79%, 89.84±2.92% and 98.57±0.72% in 88 months. Conclusion The Braile Biomédica® pericardial aortic valve prosthesis demonstrated actuarial survival and durability similar to that described in the literature, but further follow up is required to assess the incidence of prosthetic valve endocarditis and structural dysfunction in the future. PMID:25372903

  12. Early development of calcific aortic valve disease and left ventricular hypertrophy in a mouse model of combined dyslipidemia and type 2 diabetes mellitus.

    PubMed

    Le Quang, Khai; Bouchareb, Rihab; Lachance, Dominic; Laplante, Marc-André; El Husseini, Diala; Boulanger, Marie-Chloé; Fournier, Dominique; Fang, Xiang Ping; Avramoglu, Rita Kohen; Pibarot, Philippe; Deshaies, Yves; Sweeney, Gary; Mathieu, Patrick; Marette, André

    2014-10-01

    This study aimed to determine the potential impact of type 2 diabetes mellitus on left ventricular dysfunction and the development of calcified aortic valve disease using a dyslipidemic mouse model prone to developing type 2 diabetes mellitus. When compared with nondiabetic LDLr(-/-)/ApoB(100/100), diabetic LDLr(-/-)/ApoB(100/100)/IGF-II mice exhibited similar dyslipidemia and obesity but developed type 2 diabetes mellitus when fed a high-fat/sucrose/cholesterol diet for 6 months. LDLr(-/-)/ApoB(100/100)/IGF-II mice showed left ventricular hypertrophy versus C57BL6 but not LDLr(-/-)/ApoB(100/100) mice. Transthoracic echocardiography revealed significant reductions in both left ventricular systolic fractional shortening and diastolic function in high-fat/sucrose/cholesterol fed LDLr(-/-)/ApoB(100/100)/IGF-II mice when compared with LDLr(-/-)/ApoB(100/100). Importantly, we found that peak aortic jet velocity was significantly increased in LDLr(-/-)/ApoB(100/100)/IGF-II mice versus LDLr(-/-)/ApoB(100/100) animals on the high-fat/sucrose/cholesterol diet. Microtomography scans and Alizarin red staining indicated calcification in the aortic valves, whereas electron microscopy and energy dispersive x-ray spectroscopy further revealed mineralization of the aortic leaflets and the presence of inflammatory infiltrates in diabetic mice. Studies showed upregulation of hypertrophic genes (anp, bnp, b-mhc) in myocardial tissues and of osteogenic genes (spp1, bglap, runx2) in aortic tissues of diabetic mice. We have established the diabetes mellitus -prone LDLr(-/-)/ApoB(100/100)/IGF-II mouse as a new model of calcified aortic valve disease. Our results are consistent with the growing body of clinical evidence that the dysmetabolic state of type 2 diabetes mellitus contributes to early mineralization of the aortic valve and calcified aortic valve disease pathogenesis. © 2014 American Heart Association, Inc.

  13. Quantitation of valve regurgitation severity by three-dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography.

    PubMed

    Abudiab, Muaz M; Chao, Chieh-Ju; Liu, Shuang; Naqvi, Tasneem Z

    2017-07-01

    Quantitation of regurgitation severity using the proximal isovelocity acceleration (PISA) method to calculate effective regurgitant orifice (ERO) area has limitations. Measurement of three-dimensional (3D) vena contracta area (VCA) accurately grades mitral regurgitation (MR) severity on transthoracic echocardiography (TTE). We evaluated 3D VCA quantitation of regurgitant jet severity using 3D transesophageal echocardiography (TEE) in 110 native mitral, aortic, and tricuspid valves and six prosthetic valves in patients with at least mild valvular regurgitation. The ASE-recommended integrative method comprising semiquantitative and quantitative assessment of valvular regurgitation was used as a reference method, including ERO area by 2D PISA for assigning severity of regurgitation grade. Mean age was 62.2±14.4 years; 3D VCA quantitation was feasible in 91% regurgitant valves compared to 78% by the PISA method. When both methods were feasible and in the presence of a single regurgitant jet, 3D VCA and 2D PISA were similar in differentiating assigned severity (ANOVAP<.001). In valves with multiple jets, however, 3D VCA had a better correlation to assigned severity (ANOVAP<.0001). The agreement of 2D PISA and 3D VCA with the integrative method was 47% and 58% for moderate and 65% and 88% for severe regurgitation, respectively. Measurement of 3D VCA by TEE is superior to the 2D PISA method in determination of regurgitation severity in multiple native and prosthetic valves. © 2017, Wiley Periodicals, Inc.

  14. Embryological origin of the endocardium and derived valve progenitor cells: from developmental biology to stem cell-based valve repair.

    PubMed

    Pucéat, Michel

    2013-04-01

    The cardiac valves are targets of both congenital and acquired diseases. The formation of valves during embryogenesis (i.e., valvulogenesis) originates from endocardial cells lining the myocardium. These cells undergo an endothelial-mesenchymal transition, proliferate and migrate within an extracellular matrix. This leads to the formation of bilateral cardiac cushions in both the atrioventricular canal and the outflow tract. The embryonic origin of both the endocardium and prospective valve cells is still elusive. Endocardial and myocardial lineages are segregated early during embryogenesis and such a cell fate decision can be recapitulated in vitro by embryonic stem cells (ESC). Besides genetically modified mice and ex vivo heart explants, ESCs provide a cellular model to study the early steps of valve development and might constitute a human therapeutic cell source for decellularized tissue-engineered valves. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Cardiac Pathways of Differentiation, Metabolism and Contraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. 3D Fluid-Structure Interaction Simulation of Aortic Valves Using a Unified Continuum ALE FEM Model.

    PubMed

    Spühler, Jeannette H; Jansson, Johan; Jansson, Niclas; Hoffman, Johan

    2018-01-01

    Due to advances in medical imaging, computational fluid dynamics algorithms and high performance computing, computer simulation is developing into an important tool for understanding the relationship between cardiovascular diseases and intraventricular blood flow. The field of cardiac flow simulation is challenging and highly interdisciplinary. We apply a computational framework for automated solutions of partial differential equations using Finite Element Methods where any mathematical description directly can be translated to code. This allows us to develop a cardiac model where specific properties of the heart such as fluid-structure interaction of the aortic valve can be added in a modular way without extensive efforts. In previous work, we simulated the blood flow in the left ventricle of the heart. In this paper, we extend this model by placing prototypes of both a native and a mechanical aortic valve in the outflow region of the left ventricle. Numerical simulation of the blood flow in the vicinity of the valve offers the possibility to improve the treatment of aortic valve diseases as aortic stenosis (narrowing of the valve opening) or regurgitation (leaking) and to optimize the design of prosthetic heart valves in a controlled and specific way. The fluid-structure interaction and contact problem are formulated in a unified continuum model using the conservation laws for mass and momentum and a phase function. The discretization is based on an Arbitrary Lagrangian-Eulerian space-time finite element method with streamline diffusion stabilization, and it is implemented in the open source software Unicorn which shows near optimal scaling up to thousands of cores. Computational results are presented to demonstrate the capability of our framework.

  16. 3D Fluid-Structure Interaction Simulation of Aortic Valves Using a Unified Continuum ALE FEM Model

    PubMed Central

    Spühler, Jeannette H.; Jansson, Johan; Jansson, Niclas; Hoffman, Johan

    2018-01-01

    Due to advances in medical imaging, computational fluid dynamics algorithms and high performance computing, computer simulation is developing into an important tool for understanding the relationship between cardiovascular diseases and intraventricular blood flow. The field of cardiac flow simulation is challenging and highly interdisciplinary. We apply a computational framework for automated solutions of partial differential equations using Finite Element Methods where any mathematical description directly can be translated to code. This allows us to develop a cardiac model where specific properties of the heart such as fluid-structure interaction of the aortic valve can be added in a modular way without extensive efforts. In previous work, we simulated the blood flow in the left ventricle of the heart. In this paper, we extend this model by placing prototypes of both a native and a mechanical aortic valve in the outflow region of the left ventricle. Numerical simulation of the blood flow in the vicinity of the valve offers the possibility to improve the treatment of aortic valve diseases as aortic stenosis (narrowing of the valve opening) or regurgitation (leaking) and to optimize the design of prosthetic heart valves in a controlled and specific way. The fluid-structure interaction and contact problem are formulated in a unified continuum model using the conservation laws for mass and momentum and a phase function. The discretization is based on an Arbitrary Lagrangian-Eulerian space-time finite element method with streamline diffusion stabilization, and it is implemented in the open source software Unicorn which shows near optimal scaling up to thousands of cores. Computational results are presented to demonstrate the capability of our framework. PMID:29713288

  17. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis

    PubMed Central

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Objective Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Methods Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. Results A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). Conclusion The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in

  18. A technique of snaring method for fitting a prosthetic valve into the annulus.

    PubMed

    Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki

    2005-01-01

    Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.

  19. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside

    PubMed Central

    Saxon, John T; Allen, Keith B; Cohen, David J

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832

  20. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    PubMed

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  1. Aldosterone breakthrough in dogs with naturally occurring myxomatous mitral valve disease.

    PubMed

    Ames, M K; Atkins, C E; Eriksson, A; Hess, A M

    2017-06-01

    Aldosterone breakthrough (ABT) is the condition in which angiotensin converting enzyme inhibitors (ACEIs) and/or angiotensin receptor blockers fail to effectively suppress the activity of the renin angiotensin aldosterone system. The objective of this study was to determine if ABT occurs in dogs with naturally occurring myxomatous mitral valve disease receiving an ACEI, using the urine aldosterone to creatinine ratio (UAldo:C) as a measure of renin angiotensin aldosterone system activation. This study includes 39 dogs with myxomatous mitral valve disease. A UAldo:C cut-off definition (derived from a normal population of healthy, adult, and client-owned dogs) was used to determine the prevalence of ABT in this population. Spearman analysis and univariate logistic regression were used to evaluate the relationship between UAldo:C and ABT (yes/no) and eight variables (age, serum K + concentration, serum creatinine concentration, ACEI therapy duration and ACEI dosage, furosemide therapy duration and furosemide dosage, and urine sample storage time). Finally, the UAldo:C in dogs receiving spironolactone, as part congestive heart failure (CHF) therapy, was compared to dogs with CHF that were not receiving spironolactone. The prevalence of ABT was 32% in dogs with CHF and 30% in dogs without CHF. There was no relationship between either the UAldo:C or the likelihood of ABT and the eight variables. Therapy with spironolactone lead to a significant elevation of the UAldo:C. Using the UAldo:C and a relatively stringent definition of ABT, it appears that incomplete RAAS blockade is common in dogs with MMVD receiving an ACEI. The prevalence of ABT in this canine population mirrors that reported in humans. While the mechanism of ABT is likely multifactorial and still poorly understood, the proven existence of ABT in dogs offers the potential to improve the prognosis for MMVD with the addition of a mineralocorticoid receptor blocker to current therapeutic regimens

  2. [Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].

    PubMed

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.

  3. Smad2-dependent glycosaminoglycan elongation in aortic valve interstitial cells enhances binding of LDL to proteoglycans.

    PubMed

    Osman, Narin; Grande-Allen, K Jane; Ballinger, Mandy L; Getachew, Robel; Marasco, Silvana; O'Brien, Kevin D; Little, Peter J

    2013-01-01

    Calcific aortic valve disease is a progressive condition that shares some common pathogenic features with atherosclerosis. Transforming growth factor-β1 is a recognized mediator of atherosclerosis and is expressed in aortic valve lesions. Transforming growth factorβ1 stimulates glycosaminoglycan elongation of proteoglycans that is associated with increased lipid binding. We investigated the presence of transforming growth factor-β1 and downstream signaling intermediates in diseased human aortic valves and the effects of activated transforming growth factor-β1 receptor signaling on aortic valve interstitial cell proteoglycan synthesis and lipid binding as a possible mechanism for the initiation of the early lesion of calcific aortic valve disease. Diseased human aortic valve leaflets demonstrated strong immunohistochemical staining for transforming growth factor-β1 and phosphorylated Smad2/3. In primary porcine aortic valve interstitial cells, Western blots showed that transforming growth factor-β1 stimulated phosphorylation in both the carboxy and linker regions of Smad2/3, which was inhibited by the transforming growth factor-β1 receptor inhibitor SB431542. Gel electrophoresis and size exclusion chromatography demonstrated that SB431542 decreased transforming growth factor-β1-mediated [(35)S]-sulfate incorporation into proteoglycans in a dose-dependent manner. Further, in proteoglycans derived from transforming growth factor-β1-treated valve interstitial cells, gel mobility shift assays demonstrated that inhibition of transforming growth factor-β1 receptor signaling resulted in decreased lipid binding. Classic transforming growth factor-β1 signaling is present in human aortic valves in vivo and contributes to the modification of proteoglycans expressed by valve interstitial cells in vitro. These findings suggest that transforming growth factor-β1 may promote increased low-density lipoprotein binding in the early phases of calcific aortic valve disease

  4. Detection of mitral valve abnormalities by carotid Doppler flow study: implications for the management of patients with cerebrovascular disease.

    PubMed

    Weinberger, J; Goldman, M

    1985-01-01

    Patients with symptoms of cerebral ischemia are often evaluated with non-invasive carotid artery testing. An abnormal carotid Doppler ultrasound frequency shift pattern of early systolic flutter (ESF) was demonstrated by auscultation and velocity wave form analysis in patients with normal carotid bifurcations. Ten of these patients were studied with echocardiography (echo) and eight had mitral valve prolapse (MVP). To evaluate the association between ESF and MVP, a prospective blinded study was performed, recording carotid Doppler frequency shift in 50 patients referred for routine echocardiography. A total of 18 patients had ESF: 9/12 patients with MVP by echocardiography had ESF. Nine additional patients without MVP had ESF (two with mitral regurgitation and two with redundant mitral valves). The association of ESF with MVP was significant (p less than 0.001). The findings of ESF with a normal carotid artery by non-invasive testing suggests a possible mitral valve origin for symptoms of cerebrovascular disease.

  5. Pathophysiology and management of multivalvular disease

    PubMed Central

    Unger, Philippe; Clavel, Marie-Annick; Lindman, Brian R.; Mathieu, Patrick; Pibarot, Philippe

    2016-01-01

    Multivalvular disease (MVD) is a common condition with a complex pathophysiology, dependent on the specific combination of valve lesions. Diagnosis is challenging as several echocardiographic methods commonly used for the assessment of stenosis or regurgitation have been validated only in patients with single valve disease. Decisions about the timing and type of treatment should be made by a multidisciplinary heart valve team, on a case-by-case basis. Several factors should be considered, including the severity and consequences of the MVD, the patient’s life expectancy and comorbidities, the surgical risk associated with combined valve procedures, the long-term risk of morbidity and mortality associated with multiple valve prostheses, and the likelihood and risk of reoperation. The introduction of transcatheter valve therapies into clinical practice has provided new treatment options for patients with MVD, and decision-making algorithms on how to combine surgical and percutaneous treatment options are evolving rapidly. In this Review, we discuss the pathophysiology, diagnosis, and treatment of MVD, focussing on the combination of valve pathologies that are most often encountered in clinical practice. PMID:27121305

  6. Micro and nanotechnologies in heart valve tissue engineering.

    PubMed

    Hasan, Anwarul; Saliba, John; Pezeshgi Modarres, Hassan; Bakhaty, Ahmed; Nasajpour, Amir; Mofrad, Mohammad R K; Sanati-Nezhad, Amir

    2016-10-01

    Due to the increased morbidity and mortality resulting from heart valve diseases, there is a growing demand for off-the-shelf implantable tissue engineered heart valves (TEHVs). Despite the significant progress in recent years in improving the design and performance of TEHV constructs, viable and functional human implantable TEHV constructs have remained elusive. The recent advances in micro and nanoscale technologies including the microfabrication, nano-microfiber based scaffolds preparation, 3D cell encapsulated hydrogels preparation, microfluidic, micro-bioreactors, nano-microscale biosensors as well as the computational methods and models for simulation of biological tissues have increased the potential for realizing viable, functional and implantable TEHV constructs. In this review, we aim to present an overview of the importance and recent advances in micro and nano-scale technologies for the development of TEHV constructs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Serum gamma-glutamyltransferase activity is increased in patients with calcific aortic valve stenosis.

    PubMed

    Bozbas, Huseyin; Yildirir, Aylin; Demir, Ozlem; Cakmak, Abdulkadir; Karacaglar, Emir; Yilmaz, Mustafa; Eroglu, Serpil; Pirat, Bahar; Ozin, Bulent; Muderrisoglu, Haldun

    2008-07-01

    A growing body of data indicates an independent association between serum gamma-glutamyltransferase (GGT) activity, a marker of increased oxidative stress, and cardiovascular diseases. The process of calcific aortic valve disease has been shown to present characteristics of atherosclerosis. The study aim was to evaluate the possible role of serum GGT in patients with calcific aortic valve disease. The results of patients' echocardiography studies from 2005 for the presence of calcific aortic valve disease in the forms of aortic stenosis (AS) and aortic valve calcification (AVC) without significant valve stenosis, were retrospectively evaluated. Age-and gender-matched patients with normal aortic valve morphology were selected at random as a control group. A total of 383 patients was enrolled into the study (126 with AS, 133 with AVC, 124 controls). Serum GGT activity, along with other liver enzyme analyses and laboratory results, were determined and compared among the groups. Age, gender and clinical and laboratory results were similar among the three groups. Median serum GGT levels in the AS, AVC and control groups were 23.0 U/1 (mean 31.5 +/- 24.9 U/1), 22.0 U/1 (mean 27.6 +/- 18.6 U/) and 18.0 U/l (mean 22.4 +/- 16.4 U/l), respectively. Compared to controls, AS patients had significantly higher serum GGT and C-reactive protein levels, while the differences between AVC patients and controls for these parameters were not significant. The study results suggest that serum GGT activity is increased in patients with calcific AS. These increases seem to occur in advanced rather than milder forms of calcific aortic valve disease.

  8. Coronary flow reserve is impaired in patients with aortic valve calcification.

    PubMed

    Bozbas, Huseyin; Pirat, Bahar; Yildirir, Aylin; Simşek, Vahide; Sade, Elif; Eroglu, Serpil; Atar, Ilyas; Altin, Cihan; Demirtas, Saadet; Ozin, Bulent; Muderrisoglu, Haldun

    2008-04-01

    Calcific aortic valve disease is an active and progressive condition. Data indicate that aortic valve calcification (AVC) is associated with endothelial dysfunction and accepted as a manifestation of atherosclerosis. Coronary flow reserve (CFR) determined by transthoracic echocardiography has been introduced as a reliable indicator for coronary microvascular function. In this study we aimed to evaluate CFR in patients with AVC. Eighty patients, aged more than 60 years, without coronary heart disease or diabetes mellitus were included: 40 had AVC without significant stenosis (peak gradient across the valve <25 mm Hg) and 40 had normal aortic valves (controls). Using transthoracic Doppler echocardiography, we measured coronary diastolic peak flow velocities (PFV) at baseline and after dipyridamole infusion. CFR was calculated as the ratio of hyperemic to baseline diastolic PFV and was compared between groups. Mean ages for patients with AVC and controls were 68.9+/-6.2 and 67.6+/-5.9 years (P=.3). There were no significant differences regarding clinical characteristics, laboratory findings, ejection fraction, or peak aortic valve gradients. Mean diastolic PFV at baseline and during hyperemia were 28.4+/-4.2 and 59.2+/-7.8 cm/s for AVC and 27.7+/-3.9 and 68.5+/-10.5 cm/s for controls. Compared with controls, patients with AVC had significantly lower CFR values (2.12+/-0.41 versus 2.51+/-0.51; P<.0001). CFR is impaired in patients with AVC before valve stenosis develops, suggesting that microvascular-endothelial dysfunction is present during the early stages of the calcific aortic valve disease.

  9. Control Valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Wayne R.

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between amore » first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.« less

  10. Amyloid substance within stenotic aortic valves promotes mineralization.

    PubMed

    Audet, Audrey; Côté, Nancy; Couture, Christian; Bossé, Yohan; Després, Jean-Pierre; Pibarot, Philippe; Mathieu, Patrick

    2012-10-01

    Accumulation of apolipoproteins may play an important role in the pathobiology of calcific aortic valve disease (CAVD). We aimed to explore the hypothesis that apolipoprotein-derived amyloid could play a role in the development of CAVD. In 70 explanted CAVD valves and 15 control non-calcified aortic valves, we assessed the presence of amyloid by using Congo red staining. Immunohistochemistry was performed to document the presence of apolipoprotein AI (Apo-AI). Apoptosis was documented by terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL) studies performed in control and CAVD valves. Control valves were free of amyloid. Deposition of amyloid was detected in all CAVD valves, and the amount was positively correlated with plasma high-density lipoprotein and Apo-AI levels. Apo-AI within CAVD valves co-localized with intense staining of fibrillar amyloid. In turn, deposition of amyloid co-localized with apoptosis near mineralized areas. Isolation of amyloid fibrils confirmed that Apo-AI is a major component of amyloid deposits in CAVD. In vitro, CAVD-derived amyloid extracts increased apoptosis and mineralization of isolated aortic valvular interstitial cells. Apo-AI is a major component of amyloid substance present within CAVD valves. Furthermore, amyloid deposits participate in mineralization in CAVD by promoting apoptosis of valvular interstitial cells. © 2012 Blackwell Publishing Ltd.

  11. Calcific Aortic Valve Stenosis: Methods, Models, and Mechanisms

    PubMed Central

    Miller, Jordan D.; Weiss, Robert M.; Heistad, Donald D.

    2011-01-01

    Calcific aortic valve stenosis (CAVS) is a major health problem facing aging societies. The identification of osteoblast-like and osteoclast-like cells in human tissue has led to a major paradigm shift in the field. CAVS was thought to be a passive, degenerative process, whereas now the progression of calcification in CAVS is considered to be actively regulated. Mechanistic studies examining the contributions of true ectopic osteogenesis, non-osseous calcification, and ectopic osteoblast-like cells (that appear to function differently from skeletal osteoblasts) to valvular dysfunction have been facilitated by the development of mouse models of CAVS. Recent studies also suggest that valvular fibrosis, as well as calcification, may play an important role in restricting cusp movement, and CAVS may be more appropriately viewed as a fibrocalcific disease. High resolution echocardiography and magnetic resonance imaging have emerged as useful tools for testing the efficacy of pharmacological and genetic interventions in vivo. Key studies in humans and animals are reviewed that have shaped current paradigms in the field of CAVS, and suggest promising future areas for research. PMID:21617136

  12. Effect of valsalva in the pulmonary prosthetic conduit valve on hemodynamic function in a mock circulatory system.

    PubMed

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Matsuo, Satoshi; Saiki, Yoshikatsu; Yamagishi, Masaaki

    2015-01-01

    Pulmonary conduit valves are used as one of the surgical treatment methods of congenital heart diseases. We have been designing a sophisticated pulmonary conduit valve for the right ventricular outflow tract reconstruction in pediatric patients. In this study, two types of polyester grafts with or without bulging structures for the conduit valves were used and evaluated from the hemodynamic point of view focusing on the application of these conduit valves in the grown-up congenital heart failure patients. We examined valvular function in the originally developed pulmonary mock circulatory system, which consisted of a pneumatic driven right ventricular model, a pulmonary valve chamber, and an elastic pulmonary compliance model with peripheral vascular resistance units. Prior to the measurement, a bileaflet valve was sutured in each conduit. Each conduit valve was installed in the mock right ventricular outflow portion, and its leaflet motion was obtained by using a high-speed camera synchronously with pressure and flow waveforms. As a result, we could obtain hemodynamic changes in two different types of conduits for pulmonary valves, and it was indicated that the presence of the Valsalva shape might be effective for promoting valvular response in the low cardiac output condition.

  13. Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.

    PubMed

    Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René

    2017-06-01

    Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

  14. Nuclear radiation actuated valve

    DOEpatents

    Christiansen, David W.; Schively, Dixon P.

    1985-01-01

    A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.

  15. A new paradigm for obtaining marketing approval for pediatric-sized prosthetic heart valves.

    PubMed

    Yoganathan, Ajit P; Fogel, Mark; Gamble, Susan; Morton, Michael; Schmidt, Paul; Secunda, Jeff; Vidmar, Sara; Del Nido, Pedro

    2013-10-01

    Congenital heart valve disease is one of the most common abnormalities in children. There are limited technological solutions available for treating children with congenital heart valve diseases. The aim of this study is to provide the details of the consensus reached in terms of pediatric definitions, design approach, in vitro testing, and clinical trials, which may be used as guidance for developing prosthetic heart valves for the pediatric indication. In stark contrast to the various designs of adult-sized replacement valves available in the market, there are no Food and Drug Administration (FDA)-approved prosthetic heart valves available for use in the pediatric population. There is a pressing need for FDA-approved pediatric valve devices in the United States. The pediatric patient population has been typically excluded from replacement heart valve trials for several reasons. In January 2010, heart valve manufacturers and pediatric clinicians collaborated with academicians and FDA staff in a workshop to suggest ways to successfully evaluate pediatric prosthetic valves and conduct pediatric clinical trials to provide acceptable heart valve replacement options for this patient population. Recommendations, derived from ISO 5840:2005 and the 2010 FDA Draft Replacement Heart Valve Guidance, are provided for hydrodynamic, durability, and fatigue testing. The article specifically addresses in vitro and premarket and postmarket approval clinical studies that should be considered by a heart valve manufacturer for obtaining regulatory approval of pediatric sizes of prosthetic heart valve designs that are already approved for adult clinical use. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. Study of the Pressure and Velocity Across the Aortic Valve

    NASA Astrophysics Data System (ADS)

    Kyung, Seo Young; Chung, Erica Soyun; Lee, Joo Hee; Kyung, Hayoung; Choi, Si Young

    Biomechanics of the heart, requiring an extensive understanding of the complexity of the heart, have become the interests of many biomedical engineers in cardiology today. In order to study aortic valve disease, engineers have focused on the data obtained through bio-fluid flow analysis. To further this study, physical and computational analysis on the biomechanical determinants of blood flow in the stenosed aortic valve have been examined. These observations, along with the principles of cardiovascular physiology, confirm that when blood flows through the valve opening, pressure gradient across the valve is produced as a result of stenosis of the aortic valve. The aortic valve gradient is used to interpret the increase and decrease on each side of the defective valve. To compute different pressure gradients across the aortic valve, this paper analyzes Aortic Valve Areas (AVA) using simulations based on the continuity equation and Gorlin equation. The data obtained from such analysis consist of patients in the AS category that display mild Aortic Valve Velocity (AVV) and pressure gradient. Such correlation results in the construction of a dependent relationship between severe AS causing LV systolic dysfunction and the transaortic velocity.

  17. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    PubMed

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  18. Indication for percutaneous aortic valve implantation

    PubMed Central

    Akin, Ibrahim; Kische, Stephan; Rehders, Tim C.; Nienaber, Christoph A.; Rauchhaus, Mathias; Schneider, Henrik; Liebold, Andreas

    2010-01-01

    The incidence of valvular aortic stenosis has increased over the past decades due to improved life expectancy. Surgical aortic valve replacement is currently the only treatment option for severe symptomatic aortic stenosis that has been shown to improve survival. However, up to one third of patients who require lifesaving surgical aortic valve replacement are denied surgery due to high comorbidities resulting in a higher operative mortality rate. In the past such patients could only be treated with medical therapy or percutaneous aortic valvuloplasty, neither of which has been shown to improve mortality. With advances in interventional cardiology, transcatheter methods have been developed for aortic valve replacement with the goal of offering a therapeutic solution for patients who are unfit for surgical therapy. Currently there are two catheter-based treatment systems in clinical application (the Edwards SAPIEN aortic valve and the CoreValve ReValving System), utilizing either a balloon-expandable or a self-expanding stent platform, respectively. PMID:22371763

  19. The complex nature of discordant severe calcified aortic valve disease grading: new insights from combined Doppler echocardiographic and computed tomographic study.

    PubMed

    Clavel, Marie-Annick; Messika-Zeitoun, David; Pibarot, Philippe; Aggarwal, Shivani R; Malouf, Joseph; Araoz, Phillip A; Michelena, Hector I; Cueff, Caroline; Larose, Eric; Capoulade, Romain; Vahanian, Alec; Enriquez-Sarano, Maurice

    2013-12-17

    With concomitant Doppler echocardiography and multidetector computed tomography (MDCT) measuring aortic valve calcification (AVC) load, this study aimed at defining: 1) independent physiologic/structural determinants of aortic valve area (AVA)/mean gradient (MG) relationship; 2) AVC thresholds best associated with severe aortic stenosis (AS); and 3) whether, in AS with discordant MG, severe calcified aortic valve disease is generally detected. Aortic stenosis with discordant markers of severity, AVA in severe range but low MG, is a conundrum, unresolved by outcome studies. Patients (n = 646) with normal left ventricular ejection fraction AS underwent Doppler echocardiography and AVC measurement by MDCT. On the basis of AVA-indexed-to-body surface area (AVAi) and MG, patients were categorized as concordant severity grading (CG) with moderate AS (AVAi >0.6 cm²/m², MG <40 mm Hg), severe AS (AVAi ≤0.6 cm²/m², MG ≥ 40 mm Hg), discordant-severity-grading (DG) with low-MG (AVAi ≤0.6 cm(2)/m(2), MG <40 mm Hg), or high-MG (AVAi >0.6 cm(2)/m(2), MG ≥40 mm Hg). The MG (discordant in 29%) was strongly determined by AVA and flow but also independently and strongly influenced by AVC-load (p < 0.0001) and systemic arterial compliance (p < 0.0001). The AVC-load (median [interquartile range]) was similar within patients with DG (low-MG: 1,619 [965 to 2,528] arbitrary units [AU]; high-MG: 1,736 [1,209 to 2,894] AU; p = 0.49), higher than CG-moderate-AS (861 [427 to 1,519] AU; p < 0.0001) but lower than CG-severe-AS (2,931 [1,924 to 4,292] AU; p < 0.0001). The AVC-load thresholds separating severe/moderate AS were defined in CG-AS with normal flow (stroke-volume-index >35 ml/m(2)). The AVC-load, absolute or indexed, identified severe AS accurately (area under the curve ≥0.89, sensitivity ≥86%, specificity ≥79%) in men and women. Upon application of these criteria to DG-low MG, at least one-half of the patients were identified as severe calcified

  20. Mitral valve replacement with preservation of the subvalvular apparatus.

    PubMed

    Reardon, M J; David, T E

    1999-03-01

    The introduction of the Starr-Edwards valve allowed complete replacement of diseased left-sided heart valves. With improved cardiopulmonary bypass, myocardial protection, and surgical techniques the mortality rate from aortic valve replacement decreased substantially, whereas the mortality rate from mitral valve replacement remained high, largely because of low cardiac output syndrome. Increasing use of mitral valve repair techniques resulted in a marked decrease in short-term and long-term morbidity and mortality when treating patients with mitral regurgitation. Some believed that this resulted from maintenance of the mitral annular papillary muscle continuity during mitral valve repair. Subsequent experimental and clinical studies have validated the positive short-term and long-term effects of maintaining the integrity of the mitral valve subvalvular apparatus. This article considers the history of the clinical use of preservation of the subvalvular apparatus, the physiologic studies examining this concept, and the clinical data available on its use. It also examines the following: 1) mitral stenosis versus mitral regurgitation and the preservation of the subvalvular apparatus; 2) whether the anterior, posterior, or both areas of the subvalvular apparatus should be preserved; and 3) the surgical techniques for the preservation of the subvalvular apparatus and valve implantation.

  1. Contamination avoidance devices for poppet type shutoff valves

    NASA Technical Reports Server (NTRS)

    Endicott, D. L.

    1972-01-01

    The technology required to provide acceptable contamination damage avoidance characteristics for poppet type shutoff valves is discussed. Evaluation of the contamination avoidance characteristics of the basic 1T32095 propellant shutoff valve, the cycle life performance of these valves in an uncontaminated environment, and the effectiveness of various auxiliary contamination avoidance devices when used in conjunction with these poppet type valves are included. In addition, a secondary objective is to evaluate two methods of monitoring the performance of the test valves during actual operations using acoustical monitoring instrumentation.

  2. Mechanism of valve failure and efficacy of reintervention through catheterization in patients with bioprosthetic valves in the pulmonary position

    PubMed Central

    Callahan, Ryan; Bergersen, Lisa; Baird, Christopher W; Porras, Diego; Esch, Jesse J; Lock, James E; Marshall, Audrey C

    2017-01-01

    Background: Surgical and transcatheter bioprosthetic valves (BPVs) in the pulmonary position in patients with congenital heart disease may ultimately fail and undergo transcatheter reintervention. Angiographic assessment of the mechanism of BPV failure has not been previously described. Aims: The aim of this study was to determine the mode of BPV failure (stenosis/regurgitation) requiring transcatheter reintervention and to describe the angiographic characteristics of the failed BPVs and report the types and efficacy of reinterventions. Materials and Methods: This is a retrospective single-center review of consecutive patients who previously underwent pulmonary BPV placement (surgical or transcatheter) and subsequently underwent percutaneous reintervention from 2005 to 2014. Results: Fifty-five patients with surgical (41) and transcutaneous pulmonary valve (TPV) (14) implantation of BPVs underwent 66 catheter reinterventions. The surgically implanted valves underwent fifty reinterventions for indications including 16 for stenosis, seven for regurgitation, and 27 for both, predominantly associated with leaflet immobility, calcification, and thickening. Among TPVs, pulmonary stenosis (PS) was the exclusive failure mode, mainly due to loss of stent integrity (10) and endocarditis (4). Following reintervention, there was a reduction of right ventricular outflow tract gradient from 43 ± 16 mmHg to 16 ± 10 mmHg (P < 0.001) and RVp/AO ratio from 0.8 ± 0.2 to 0.5 ± 0.2 (P < 0.001). Reintervention with TPV placement was performed in 45 (82%) patients (34 surgical, 11 transcatheter) with no significant postintervention regurgitation or paravalvular leak. Conclusion: Failing surgically implanted BPVs demonstrate leaflet calcification, thickness, and immobility leading to PS and/or regurgitation while the mechanism of TPV failure in the short- to mid-term is stenosis, mainly from loss of stent integrity. This can be effectively treated with a catheter-based approach

  3. Apparatus comprising magnetically actuated valves and uses thereof

    DOEpatents

    Edwards, Thayne L.; Harper, Jason C.

    2016-07-12

    The present invention, in part, relates to an apparatus having a single-use, normally-closed fluidic valve that is initially maintained in the closed position by a valve element bonded to an adhesive coating. The valve is opened using a magnetic force. The valve element includes a magnetic material or metal. In some examples, the valve is opened by bringing a magnet in proximity to the valve element to provide a magnetic force that delaminates the valve element from the adhesive coating. In particular, the apparatus can be useful for on-chip amplification and/or detection of various targets, including biological targets and any amplifiable targets. Such apparatuses and methods are useful for in-field or real-time detection of targets, especially in limited resource settings.

  4. Depressurization valve

    DOEpatents

    Skoda, G.I.

    1989-03-28

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring-preferably of the Belleville variety-acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion.

  5. Patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement. Experimental study.

    PubMed

    Manouguian, S; Abu-Aishah, N; Neitzel, J

    1979-09-01

    The experimental results of patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement are reported. The operative technique of this new surgical method is described and the indications are discussed.

  6. [Medicinal treatment of tricuspid valve regurgitation].

    PubMed

    Lankeit, M; Keller, K; Tschöpe, C; Pieske, B

    2017-11-01

    The vast majority of tricuspid valve regurgitations are of low degree without prognostic relevance in healthy individuals; however, morbidity and mortality increase with the degree of regurgitation, which can be secondary to either primary (structural) or secondary (functional) alterations of the valve. Due to the frequent lack of symptoms, echocardiographic examinations should be annually performed in patients with higher degree (at least moderate) tricuspid valve regurgitation, in particular in the presence of risk factors. Individual therapeutic management strategies should consider the etiology of the tricuspid valve regurgitation, the degree of regurgitation, the valve pathology and the risk-to-benefit ratio of the envisaged therapeutic procedure. Medicinal treatment options for tricuspid valve regurgitation are limited and generalized recommendations cannot be provided due to the lack of conclusive clinical trials. Symptomatic therapeutic measures encompass especially (loop) diuretics for the reduction of preload and afterload of the right ventricle. Pharmaceutical reduction of the heart rate should be avoided in patients with right heart insufficiency. While symptomatic therapeutic measures are often associated with only moderate effects, the most effective therapy of tricuspid valve regurgitation consists in the treatment of underlying illnesses, in most cases pulmonary hypertension due to pulmonary arterial hypertension (PAH), left heart disease or acute pulmonary embolism. Based on a number of published clinical studies and licensing of new drugs, treatment options for patients with PAH and heart failure with reduced ejection fraction (HFrEF) have substantially improved during the past years allowing for a differentiated, individualized management.

  7. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.

    PubMed

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-06-01

    Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.

  8. A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery.

    PubMed

    Leone, Alessandro; Bruno, Piergiorgio; Cammertoni, Federico; Massetti, Massimo

    2015-07-01

    Valve-sparing operations for the treatment of aortic root disease with a structurally normal aortic valve are increasingly performed as they avoid prosthesis-related complications. Short- and long-term results are critically dependent on perfect intraoperative restoration of valve anatomy and function. Residual aortic regurgitation is the main cause of early failure, and it is the most common motive for reoperation. However, intraoperative morphofunctional valve assessment requires expertise, and only transesophageal echocardiography can provide reliable information. We describe a simple, economic, reproducible hydrostatic test to intraoperatively evaluate valve competency under direct visualization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Fast valve

    DOEpatents

    Van Dyke, W.J.

    1992-04-07

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing. 4 figs.

  10. Fast valve

    DOEpatents

    Van Dyke, William J.

    1992-01-01

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing.

  11. The Impact of Obesity on Postoperative Outcomes in Adults with Congenital Heart Disease Undergoing Pulmonary Valve Replacement.

    PubMed

    Buelow, Matthew W; Earing, Michael G; Hill, Garick D; Cohen, Scott B; Bartz, Peter J; Tweddell, James S; Ginde, Salil

    2015-01-01

    The impact of obesity on surgical morbidity in adults with congenital heart disease is currently unknown. The aim of our study was to investigate the impact of obesity on postoperative outcomes in adults with congenital heart disease undergoing reoperation for pulmonary valve replacement. A retrospective analysis was performed assessing the influence of obesity on surgical outcomes. Obesity was defined as a body mass index ≥30 kg/m2. The mean body mass index of the cohort was 25.9 ± 6.9 kg/m2 . The cohort included 71 patients with 17 patients (24%) being obese. There was no postoperative mortality. Obese patients had a longer hospital length of stay (6.6 vs. 4.7 days; P < .001) and increased incidence of postoperative arrhythmias (29% vs. 5.6%; P = .003) compared with nonobese patients. Multivariable analysis performed using logistic regression with backwards elimination demonstrated obesity was independently associated with hospital length of stay >5 days (odds ratio [OR] = 5.2; 95% confidence interval [CI]: 1.5-18.2, P = .01) and with increased postoperative arrhythmias (OR = 4.2; 95% CI: 1.7-40, P < .01). Obesity is associated with increased morbidity in adults with congenital heart disease undergoing pulmonary valve replacement, including longer hospitalization and higher risk for postoperative arrhythmias. © 2015 Wiley Periodicals, Inc.

  12. Study on hydraulic exciting vibration due to flexible valve in pump system with method of characteristics in the time domain

    NASA Astrophysics Data System (ADS)

    Yu, Y. H.; Liu, D.; Yang, X. F.; Si, J.

    2017-08-01

    To analyse the flow characteristics of leakage as well as the mechanism of selfexcited vibration in valves, the method of characteristics was used to assess the effect of flexible valve leakage on the self-excited vibration in water-supply pump system. Piezometric head in upstream of the valve as a function of time was obtained. Two comparative schemes were proposed to simulate the process of self-excited vibration by changing the length, the material of the pipeline and the leakage of valves in the above pump system. It is shown that the length and material of the pipe significantly affect the amplitude and cycle of self-excited vibration as well as the increasing rate of the vibration amplitude. In addition, the leakage of the valve has little influence on the amplitude and cycle of self-excited vibration, but has a significant effect on the increasing rate of vibration amplitude. A pipe explosion accident may occur without the inhibiting of self-excited vibration.

  13. Increased dietary intake of vitamin A promotes aortic valve calcification in vivo

    PubMed Central

    Huk, Danielle J.; Hammond, Harriet L.; Kegechika, Hiroyuki; Lincoln, Joy

    2013-01-01

    Objective Calcific aortic valve disease (CAVD) is a major public health problem with no effective treatment available other than surgery. We previously showed that mature heart valves calcify in response to retinoic acid (RA) treatment through downregulation of the SRY-transcription factor Sox9. In this study, we investigated the effects of excess vitamin A and its metabolite RA on heart valve structure and function in vivo, and examined the molecular mechanisms of RA signaling during the calcification process in vitro. Methods and Results Using a combination of approaches, we defined CAVD pathogenesis in mice fed 200 IU/g and 20 IU/g of retinyl palmitate for 12 months at molecular, cellular and functional levels. We show that mice fed excess vitamin A develop aortic valve stenosis and leaflet calcification associated with increased expression of osteogenic genes and decreased expression of cartilaginous markers. Using a pharmacological approach, we show that RA-mediated Sox9 repression and calcification is regulated by classical RA signaling and requires both RAR and RXR receptors. Conclusions Our studies demonstrate that excess vitamin A dietary intake promotes heart valve calcification in vivo. Therefore suggesting that hypervitaminosis A could serve as a new risk factor of CAVD in the human population. PMID:23202364

  14. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    PubMed

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  15. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease

    PubMed Central

    SOTO-BUSTOS, Ángel; CARO-VADILLO, Alicia; MARTÍNEZ-DE-MERLO, Elena; ALONSO-ALEGRE, Elisa González

    2017-01-01

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease. PMID:28845021

  16. Valve leakage inspection, testing, and maintenance process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aikin, J.A.; Reinwald, J.W.

    1989-01-01

    Atomic Energy of Canada Limited-Research Company (AECL-RC), Chalk River, has more than 50 person-years dedicated toward the leak-free valve. In the early 1970s, the Chalk River Nuclear Laboratories (CRNL) developed valve stem live-loading and recently completed the packing tests for the Electric Power Research Institute (EPRI)-funded Valve Packing Improvement Study. Current safety concerns with asbestos-based valve packings and the difficulty in removing newer graphite packings prompted CRNL to investigate methods to improve valve repacking procedures. The present practice of valve packing replacement is very labor-intensive, requiring use of hand tools such as corkscrew devices and special packing picks. Use ofmore » water jets to cut or fragment the packing for withdrawal from the stuffing box does improve the process, but removal of the lantern or junk rings is still difficult. To address these problems, AECL-RC has developed a unique valve maintenance process designed to reduce person-rem exposures, the risk of scoring the stem or stuffing box, and maintenance costs and to improve the engineering quality of valve repair.« less

  17. Bicuspid aortic valves are associated with increased wall and turbulence shear stress levels compared to trileaflet aortic valves.

    PubMed

    Saikrishnan, Neelakantan; Mirabella, Lucia; Yoganathan, Ajit P

    2015-06-01

    Congenital bicuspid aortic valves (BAVs) are associated with accelerated disease progression, such as leaflet calcification and ascending aorta dilatation. Although common underlying genetic factors have been implicated in accelerated disease in BAV patients, several studies have suggested that altered hemodynamics also play a role in this disease process. The present study compares turbulence and wall shear stress (WSS) measurements between various BAV and trileaflet aortic valve (TAV) models to provide information for mechanobiological models of BAV disease. BAV and TAV models were constructed from excised porcine aortic valves to simulate parametric variations in BAV stenosis, hemodynamics and geometry. Particle image velocimetry experiments were conducted at physiological pressure conditions to characterize velocity fields in the ascending aorta. The velocity fields were post-processed to calculate turbulence, viscous and wall shear stresses in the ascending aorta. Stenosed BAV models showed the presence of eccentric systolic jets, causing increased WSS. Lower cardiac output resulted in a narrower jet, lower turbulence and lower viscous shear stress (VSS). The specific severe stenosis BAV model studied here showed reduced WSS due to reduction in non-fused leaflet mobility. Dilation of the aorta did not affect any turbulence or VSS, but reduced the WSS. In comparison with BAVs, TAVs have similar VSS values, but much smaller WSS and turbulence levels. These increased turbulence  and WSS levels in BAVs may play a key role in amplifying the biological responses of the ascending aorta wall and valvular leaflets, and support the hemodynamic underpinnings of BAV disease processes.

  18. Relation of Aortic Valve Calcium to Chronic Kidney Disease (from the Chronic Renal Insufficiency Cohort [CRIC] Study)

    PubMed Central

    Guerraty, Marie A.; Chai, Boyang; Hsu, Jesse Yenchih; Ojo, Akinlolu O.; Gao, Yanlin; Yang, Wei; Keane, Martin G.; Budoff, Matthew J.; Mohler, Emile R.

    2015-01-01

    Although subjects with chronic kidney disease (CKD) are at markedly increased risk for cardiovascular mortality, the relationship between CKD and aortic valve calcification has not been fully elucidated. Also, few data are available on the relationship of aortic valve calcification and earlier stages of CKD. We sought to assess the relationship of aortic valve calcium (AVC) with estimated glomerular filtration rate (eGFR), traditional and novel cardiovascular risk factors, and markers of bone metabolism in the Chronic Renal Insufficiency Cohort (CRIC) Study. All patients who underwent aortic valve scanning in the CRIC study were included. The relationship between AVC and eGFR, traditional and novel cardiovascular risk factors, and markers of calcium metabolism were analyzed using both unadjusted and adjusted regression models. A total of 1964 CRIC participants underwent computed tomography for AVC quantification. Decreased renal function was independently associated with increased levels of AVC (eGFR 47.11 ml/min/1.73m2, 44.17 ml/min/1.73m2, and 39 ml/min/1.73m2, respectively, p< 0.001). This association persisted after adjusting for traditional, but not novel, AVC risk factors. Adjusted regression models identified several traditional and novel risk factors for AVC in patients with CKD. There was a difference in AVC risk factors between black and non-black patients. In conclusion, our study shows that eGFR is associated in a dose-dependent manner with AVC in patients with CKD, and this association is independent of traditional cardiovascular risk factors. PMID:25791240

  19. Echocardiographic assessment of cardiac disease

    NASA Technical Reports Server (NTRS)

    Popp, R. L.

    1976-01-01

    The physical principles and current applications of echocardiography in assessment of heart diseases are reviewed. Technical considerations and unresolved points relative to the use of echocardiography in various disease states are stressed. The discussion covers normal mitral valve motion, mitral stenosis, aortic regurgitation, atrial masses, mitral valve prolapse, and idiopathic hypertrophic subaortic stenosis. Other topics concern tricuspic valve abnormalities, aortic valve disease, pulmonic valve, pericardial effusion, intraventricular septal motion, and left ventricular function. The application of echocardiography to congenital heart disease diagnosis is discussed along with promising ultrasonic imaging systems. The utility of echocardiography in quantitative evaluation of cardiac disease is demonstrated.

  20. Implementation of transcatheter aortic valve replacement in California: Influence on aortic valve surgery.

    PubMed

    Maximus, Steven; Milliken, Jeffrey C; Danielsen, Beate; Shemin, Richard; Khan, Junaid; Carey, Joseph S

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) procedures were introduced in 2011. Initially, procedures were limited to patients who were not surgical candidates, but subsequently high-risk surgical candidates were considered for TAVR. The influence on aortic valve surgery in California is unknown. The California Office of Statewide Health Planning and Development hospitalized patient discharge database was queried for the years 2009 through 2014. isolated surgical aortic valve and aortic valve/coronary artery bypass graft (SAVR) and TAVR procedures were identified by International Classification of Diseases-9th revision clinical modification procedure codes. Seven TAVR programs were introduced in 2011, 12 in 2012, 3 in 2013, and 6 in 2014. SAVR procedure volumes were compared from the 2 years before institution with SAVR volumes during the year(s) after institution of the TAVR program in these 28 hospitals. Overall, surgical volumes increased during the first, second, and third years after implementation of TAVR procedures. Among 7 hospitals with 4-year programs, surgical volumes increased to a maximum of 15.5% during the third year, then began to decrease. The hospital performing the largest number of TAVR procedures showed a marked decrease in SAVR volume by the fourth year, suggesting a shift of SAVR candidates to TAVR. Among all hospitals with 4-year programs, TAVR exceeded SAVR procedures by the fourth year. In California overall, SAVR increased during 2011 through 2013, due primarily to increasing volume of isolated SAVR procedures. Statewide, isolated SAVR increased from a yearly average of 3111 procedures during 2009-2010 to 3592 (+15.5%) in 2013, then decreased slightly in 2014. SAVR plus coronary artery bypass graft procedures decreased during the same time period. After implementation of TAVR, hospital SAVR volumes increased moderately, then began to decrease by the fourth year, when TAVR volume exceeded SAVR. Surgical candidates may be identified

  1. Will Catheter Interventions Replace Surgery for Valve Abnormalities?

    PubMed Central

    O’Byrne, Michael L; Gillespie, Matthew J

    2015-01-01

    Purpose of Review Catheter-based valve technologies have evolved rapidly over the last decade. Transcatheter aortic valve replacement (TAVR) has become a routine procedure in high-risk adult patients with calcific aortic stenosis. In patients with congenital heart disease (CHD), transcatheter pulmonary valve replacement represents a transformative technology for right ventricular outflow tract dysfunction with the potential to expand to other indications. This review aims to summarize 1) the current state of the art for transcatheter valve replacement (TVR) in CHD, 2) the expanding indications for TVR, and 3) the technological obstacles to optimizing TVR. Recent findings Multiple case series have demonstrated that TVR with the Melody transcatheter pulmonary valve in properly selected patients is safe, effective, and durable in short-term follow-up. The Sapien transcatheter heart valve represents an alternative device with similar safety and efficacy in limited studies. Innovative use of current valves has demonstrated the flexibility of TVR, while highlighting the need for devices to address the broad range of post-operative anatomies either with a single device or strategies to prepare the outflow tract for subsequent device deployment. Summary The potential of TVR has not been fully realized, but holds promise in treatment of CHD. PMID:24281347

  2. Depressurization valve

    DOEpatents

    Skoda, George I.

    1989-01-01

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring--preferably of the Belleville variety--acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion. The latch plate in surrounding the stem is limited in its outward movement by a boss attached to the stem at the end of

  3. Methodological inaccuracies in clinical aortic valve severity assessment: insights from computational fluid dynamic modeling of CT-derived aortic valve anatomy

    NASA Astrophysics Data System (ADS)

    Traeger, Brad; Srivatsa, Sanjay S.; Beussman, Kevin M.; Wang, Yechun; Suzen, Yildirim B.; Rybicki, Frank J.; Mazur, Wojciech; Miszalski-Jamka, Tomasz

    2016-04-01

    Aortic stenosis is the most common valvular heart disease. Assessing the contribution of the valve as a portion to total ventricular load is essential for the aging population. A CT scan for one patient was used to create one in vivo tricuspid aortic valve geometry and assessed with computational fluid dynamics (CFD). CFD simulated the pressure, velocity, and flow rate, which were used to assess the Gorlin formula and continuity equation, current clinical diagnostic standards. The results demonstrate an underestimation of the anatomic orifice area (AOA) by Gorlin formula and overestimation of AOA by the continuity equation, using peak velocities, as would be measured clinically by Doppler echocardiography. As a result, we suggest that the Gorlin formula is unable to achieve the intended estimation of AOA and largely underestimates AOA at the critical low-flow states present in heart failure. The disparity in the use of echocardiography with the continuity equation is due to the variation in velocity profile between the outflow tract and the valve orifice. Comparison of time-averaged orifice areas by Gorlin and continuity with instantaneous orifice areas by planimetry can mask the errors of these methods, which is a result of the assumption that the blood flow is inviscid.

  4. Fault detection and diagnosis of diesel engine valve trains

    NASA Astrophysics Data System (ADS)

    Flett, Justin; Bone, Gary M.

    2016-05-01

    This paper presents the development of a fault detection and diagnosis (FDD) system for use with a diesel internal combustion engine (ICE) valve train. A novel feature is generated for each of the valve closing and combustion impacts. Deformed valve spring faults and abnormal valve clearance faults were seeded on a diesel engine instrumented with one accelerometer. Five classification methods were implemented experimentally and compared. The FDD system using the Naïve-Bayes classification method produced the best overall performance, with a lowest detection accuracy (DA) of 99.95% and a lowest classification accuracy (CA) of 99.95% for the spring faults occurring on individual valves. The lowest DA and CA values for multiple faults occurring simultaneously were 99.95% and 92.45%, respectively. The DA and CA results demonstrate the accuracy of our FDD system for diesel ICE valve train fault scenarios not previously addressed in the literature.

  5. Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions.

    PubMed

    Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T

    2015-01-01

    Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Whereas much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells.

  6. Current Progress in Tissue Engineering of Heart Valves: Multiscale Problems, Multiscale Solutions

    PubMed Central

    Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T.

    2016-01-01

    Introduction Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. Areas covered This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally-derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Expert opinion While much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells. PMID:26027436

  7. Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease.

    PubMed

    Höllmer, M; Willesen, J L; Tolver, A; Koch, J

    2017-02-01

    Myxomatous mitral valve disease (MMVD) induces progressive left atrial (LA) enlargement. The LA modulates left ventricular filling and performance through its reservoir, conduit, and contractile function. Assessment of LA size and function may provide valuable information on the level of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. This prospective study included 205 client-owned dogs of different breeds, 114 healthy dogs, and 91 dogs with MMVD of different disease severities. Using two-dimensional echocardiography, the biplane area-length method was applied to assess LA volume and calculate volumetric indices of LA reservoir, conduit, and contractile function. Left atrial volume and LA stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume <2.25mL/kg was the optimal cut off identified for excluding congestive heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100%. An active LA emptying fraction <24% and/or a LA expansion index <126% were suggestive of congestive heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. Dogs with MMVD appear to have larger LA volumes with poorer LA function. Deteriorating LA function, characterized by a decreasing reservoir and active contractile function, was evident in dogs with MMVD with increasing disease severity. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves

    PubMed Central

    Schipke, Kimberly J.; Filip To, S. D.; Warnock, James N.

    2011-01-01

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage1-3. Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease4. The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve5. Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves6-9. Pulsatile bioreactors have also been developed to study a range of tissues including cartilage10, bone11 and bladder12. The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the

  9. Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.

    PubMed

    Schipke, Kimberly J; To, S D Filip; Warnock, James N

    2011-08-23

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed

  10. Fluid-Structure Model of Lymphatic Valve and Vessel

    NASA Astrophysics Data System (ADS)

    Wolf, Ki; Ballard, Matthew; Nepiyushchikh, Zhanna; Razavi, Mohammad; Dixon, Brandon; Alexeev, Alexander

    The lymphatic system is a part of the circulatory system that performs a range of important functions such as transportation of interstitial fluid, fatty acid, and immune cells. The lymphatic vessels are composed of contractile walls to pump lymph against adverse pressure gradient and lymphatic valves that prevent back flow. Despite the importance of lymphatic system, the contribution of mechanical and geometric changes of lymphatic valves and vessels in pathologies of lymphatic dysfunction, such as lymphedema, is not well understood. We developed a coupled fluid-solid computational model to simultaneously simulate a lymphatic vessel, valve, and flow. A lattice Boltzmann model is used to represent the fluid component, while lattice spring model is used for the solid component of the lymphatic vessel, whose mechanical properties are derived experimentally. Behaviors such as lymph flow pattern and lymphatic valve performance against backflow and adverse pressure gradient under varied parameters of lymphatic valve and vessel geometry and mechanical properties are investigated to provide a better insight into the dynamics of lymphatic vessels, valves, and system and give insight into how they might fail in disease. NSF CMMI-1635133.

  11. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome.

    PubMed

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-09-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve "leaflets" that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the "surgeons view." We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes.

  12. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome

    PubMed Central

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-01-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve “leaflets” that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the “surgeons view.” We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes. PMID:25298694

  13. Automated segmentation and geometrical modeling of the tricuspid aortic valve in 3D echocardiographic images.

    PubMed

    Pouch, Alison M; Wang, Hongzhi; Takabe, Manabu; Jackson, Benjamin M; Sehgal, Chandra M; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2013-01-01

    The aortic valve has been described with variable anatomical definitions, and the consistency of 2D manual measurement of valve dimensions in medical image data has been questionable. Given the importance of image-based morphological assessment in the diagnosis and surgical treatment of aortic valve disease, there is considerable need to develop a standardized framework for 3D valve segmentation and shape representation. Towards this goal, this work integrates template-based medial modeling and multi-atlas label fusion techniques to automatically delineate and quantitatively describe aortic leaflet geometry in 3D echocardiographic (3DE) images, a challenging task that has been explored only to a limited extent. The method makes use of expert knowledge of aortic leaflet image appearance, generates segmentations with consistent topology, and establishes a shape-based coordinate system on the aortic leaflets that enables standardized automated measurements. In this study, the algorithm is evaluated on 11 3DE images of normal human aortic leaflets acquired at mid systole. The clinical relevance of the method is its ability to capture leaflet geometry in 3DE image data with minimal user interaction while producing consistent measurements of 3D aortic leaflet geometry.

  14. Excess flow shutoff valve

    DOEpatents

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  15. The Economics of Transcatheter Valve Interventions.

    PubMed

    Sud, Maneesh; Tam, Derrick Y; Wijeysundera, Harindra C

    2017-09-01

    A subset of patients who require correction of a stenotic or incompetent valve are deemed to be at excessive surgical risk, which precludes surgical repair or replacement. Transcatheter valve interventions are viable alternatives in these patients. However, these technologies are costly, and in the setting of a constrained Canadian health care budget, economic value is an important consideration to allow for fair allocation of scarce resources. Accordingly, we review the economic literature on transcatheter valve interventions, targeting a general audience. Our specific goals are highlighting how best to interpret these studies and discuss the implications of these technologies on the Canadian health care system. Transcatheter aortic valve replacement (TAVR) is a cost-effective alternative for inoperable patients who otherwise would receive medical therapy. When compared with surgical aortic valve replacement (SAVR), TAVR is associated with significant reductions in postprocedure hospital resource use, which offsets the substantially higher cost of the TAVR valve system relative to SAVR valves. Although cost-effectiveness estimates for TAVR in high-risk operable candidates vary widely across studies, based on contemporary data from the perspective of the Canadian health care system, TAVR is likely to provide economic value. Recent studies suggest that when compared with medical therapy for severe degenerative mitral regurgitation, the MitraClip (Abbott, Abbott Park, IL) may offer economic value in high-risk patients; however, in the absence of randomized controlled trials, this is speculative. Nonetheless, these transcatheter technologies represent a paradigm shift in the management of valvular disease; their dissemination will have substantial impact in cardiovascular care delivery. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  16. Mitral Valve Surgery in Patients with Systemic Lupus Erythematosus

    PubMed Central

    Hekmat, Manouchehr; Ghorbani, Mohsen; Ghaderi, Hamid; Majidi, Masoud; Beheshti, Mahmood

    2014-01-01

    Valvular heart disease is the common cardiac manifestation of systemic lupus erythematosus (SLE) with a tendency for mitral valve regurgitation. In this study we report a case of mitral valve replacement for mitral stenosis caused by Libman-Sacks endocarditis in the setting of SLE. In addition, we provide a systematic review of the literature on mitral valve surgery in the presence of Libman-Sacks endocarditis because its challenge on surgical options continues. Surgical decision depends on structural involvement of mitral valve and presence of active lupus nephritis and antiphospholipid antibody syndrome. Review of the literature has also shown that outcome is good in most SLE patients who have undergone valvular surgery, but association of antiphospholipid antibody syndrome with SLE has negative impact on the outcome. PMID:25401131

  17. Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.

    PubMed

    Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas

    2017-06-01

    Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.

  18. Are anticoagulant independent mechanical valves within reach—fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models

    PubMed Central

    Siegel, Rolland

    2015-01-01

    Background Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Methods Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Results Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Conclusions Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration

  19. Novel liquid equilibrium valving on centrifugal microfluidic CD platform.

    PubMed

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Arof, Hamzah; Madou, Marc

    2013-01-01

    One of the main challenges faced by researchers in the field of microfluidic compact disc (CD) platforms is the control of liquid movement and sequencing during spinning. This paper presents a novel microfluidic valve based on the principle of liquid equilibrium on a rotating CD. The proposed liquid equilibrium valve operates by balancing the pressure produced by the liquids in a source and a venting chamber during spinning. The valve does not require external forces or triggers, and is able to regulate burst frequencies with high accuracy. In this work, we demonstrate that the burst frequency can be significantly raised by making just a small adjustment of the liquid height in the vent chamber. Finally, the proposed valve ng method can be used separately or combined with other valving methods in advance microfluidic processes.

  20. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    PubMed

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p < 0.01). Patient-specific, 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  1. Mitral valve morphology assessed by three-dimensional transthoracic echocardiography in healthy dogs and dogs with myxomatous mitral valve disease.

    PubMed

    Menciotti, G; Borgarelli, M; Aherne, M; Wesselowski, S; Häggström, J; Ljungvall, I; Lahmers, S M; Abbott, J A

    2017-04-01

    To assess differences in morphology of the mitral valve (MV) between healthy dogs and dogs affected by myxomatous mitral valve disease (MMVD) using real-time transthoracic three-dimensional echocardiography (RT3DE). Thirty-four were normal dogs and 79 dogs were affected by MMVD. Real-time transthoracic three-dimensional echocardiography mitral datasets were digitally recorded and analyzed using dedicated software. The following variables were obtained and compared between healthy dogs and dogs with MMVD at different stages: antero-posterior annulus diameter, anterolateral-posteromedial annulus diameter, commissural diameter, annulus height, annulus circumference, annulus area, anterior leaflet length, anterior leaflet area, posterior leaflet length, posterior leaflet area, non-planar angle, annulus sphericity index, tenting height, tenting area, tenting volume, the ratio of annulus height and commissural diameter. Dogs with MMVD had a more circular MV annulus compared to healthy dogs as demonstrated by an increased annulus sphericity index (p=0.0179). Affected dogs had a less saddle-shaped MV manifest as a decreased annulus height to commissural width ratio (p=0.0004). Tenting height (p<0.0001), area (p<0.0001), and volume (p<0.0001) were less in affected dogs. Real-time transthoracic three-dimensional echocardiography analysis demonstrated that dogs affected by MMVD had a more circular and less saddle-shaped MV annulus, as well as reduced tenting height area and volume, compared to healthy dogs. Multiple variables differed between dogs at different stages of MMVD. Diagnostic and prognostic utility of these variables, and the significance of these changes in the pathogenesis and natural history of MMVD, require further attention. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Reduced-impact sliding pressure control valve for pneumatic hammer drill

    DOEpatents

    Polsky, Yarom [Oak Ridge, TN; Grubelich, Mark C [Albuquerque, NM; Vaughn, Mark R [Albuquerque, NM

    2012-05-15

    A method and means of minimizing the effect of elastic valve recoil in impact applications, such as percussive drilling, where sliding spool valves used inside the percussive device are subject to poor positioning control due to elastic recoil effects experienced when the valve impacts a stroke limiting surface. The improved valve design reduces the reflected velocity of the valve by using either an energy damping material, or a valve assembly with internal damping built-in, to dissipate the compression stress wave produced during impact.

  3. Reasons for conversion and adverse intraoperative events in Endoscopic Port Access™ atrioventricular valve surgery and minimally invasive aortic valve surgery.

    PubMed

    van der Merwe, Johan; Van Praet, Frank; Stockman, Bernard; Degrieck, Ivan; Vermeulen, Yvette; Casselman, Filip

    2018-02-14

    This study reports the factors that contribute to sternotomy conversions (SCs) and adverse intraoperative events in minimally invasive aortic valve surgery (MI-AVS) and minimally invasive Endoscopic Port Access™ atrioventricular valve surgery (MI-PAS). In total, 3780 consecutive patients with either aortic valve disease or atrioventricular valve disease underwent minimally invasive valve surgery (MIVS) at our institution between 1 February 1997 and 31 March 2016. MI-AVS was performed in 908 patients (mean age 69.2 ± 11.3 years, 45.2% women, 6.2% redo cardiac surgery) and MI-PAS in 2872 patients (mean age 64.1 ± 13.3 years, 46.7% women, 12.2% redo cardiac surgery). A cumulative total of 4415 MIVS procedures (MI-AVS = 908, MI-PAS = 3507) included 1537 valve replacements (MI-AVS = 896, MI-PAS = 641) and 2878 isolated or combined valve repairs (MI-AVS = 12, MI-PAS = 2866). SC was required in 3.0% (n = 114 of 3780) of MIVS patients, which occurred in 3.1% (n = 28 of 908) of MI-AVS patients and 3.0% (n = 86 of 2872) of MI-PAS patients, respectively. Reasons for SC in MI-AVS included inadequate visualization (n = 4, 0.4%) and arterial cannulation difficulty (n = 7, 0.8%). For MI-PAS, SC was required in 54 (2.5%) isolated mitral valve procedures (n = 2183). Factors that contributed to SC in MI-PAS included lung adhesions (n = 35, 1.2%), inadequate visualization (n = 2, 0.1%), ventricular bleeding (n = 3, 0.1%) and atrioventricular dehiscence (n = 5, 0.2%). Neurological deficit occurred in 1 (0.1%) and 3 (3.5%) MI-AVS and MI-PAS conversions, respectively. No operative or 30-day mortalities were observed in MI-AVS conversions (n = 28). The 30-day mortality associated with SC in MI-PAS (n = 86) was 10.5% (n = 9). MIVS is increasingly being recognized as the 'gold-standard' for surgical valve interventions in the context of rapidly expanding catheter-based technology and increasing

  4. Experimental research of flow servo-valve

    NASA Astrophysics Data System (ADS)

    Takosoglu, Jakub

    Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.

  5. The impact of mitral stenosis on outcomes of aortic valve stenosis patient undergoing surgical aortic valve replacement or transcatheter aortic valve replacement.

    PubMed

    Al-Khadra, Yasser; Darmoch, Fahed; Baibars, Motaz; Kaki, Amir; Fanari, Zaher; Alraies, M Chadi

    2018-05-17

    The concomitant presence of mitral stenosis (MS) in the setting of symptomatic aortic stenosis represent a clinical challenge. Little is known regarding the outcome of mitral stenosis (MS) patients undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). Therefore, we sought to study the outcome of MS patients undergoing aortic valve replacement (AVR). Using weighted data from the National Inpatient Sample (NIS) database between 2011 and 2014, we identified patients who were diagnosed with MS. Patients who had undergone TAVR as a primary procedure were identified and compared to patients who had SAVR. Univariate and multivariate logistic regression analysis were performed for the outcomes of in-hospital mortality, length of stay (LOS), blood transfusion, postprocedural hemorrhage, vascular, cardiac and respiratory complications, permanent pacemaker placement (PPM), postprocedural stroke, acute kidney injury (AKI), and discharge to an outside facility. A total of 4524 patients were diagnosed with MS, of which 552 (12.2%) had TAVR and 3972 (87.8%) had SAVR. TAVR patients were older (79.9 vs 70.0) with more females (67.4% vs 60.0%) and African American patients (7.7% vs 7.1%) (P < 0.001). In addition, the TAVR group had more comorbidities compared to SAVR in term of coronary artery disease (CAD), congestive heart failure (CHF), chronic lung disease, hypertension (HTN), chronic kidney disease (CKD), and peripheral vascular disease (PVD) (P < 0.001 for all). Using Multivariate logistic regression, and after adjusting for potential risk factors, TAVR patients had lower in-hospital mortality (7.9% vs 8.1% adjusted Odds Ratio [aOR], 0.615; 95% confidence interval [CI], 0.392-0.964, P = 0.034), shorter LOS. Also, TAVR patients had lower rates of cardiac and respiratory complications, PPM, AKI, and discharge to an outside facility compared with the SAVR group. In patients with severe aortic stenosis and concomitant

  6. Absence of posterior tricuspid valve leaflet and valve reconstruction

    PubMed Central

    Komoda, Takeshi; Stamm, Christof; Fleck, Eckart; Hetzer, Roland

    2012-01-01

    We report a rare case of the absence of a posterior tricuspid valve leaflet. A male patient, aged 46, suffering from severe tricuspid valve regurgitation (TR) of unknown aetiology and atrial septal aneurysm was referred to our hospital for surgery. On surgical inspection, the posterior tricuspid valve leaflet and its subvalvular apparatus were completely absent and only the valve annulus was seen in the corresponding position. The anterior and septal leaflets were normal. We successfully reconstructed the tricuspid valve as follows: the head of an anterior papillary muscle was approximated to the ventricular septum (Sebening stitch). After the approximation of the centre of the tricuspid annulus of the anterior leaflet to the tricuspid annulus on the opposite side, a sizer of 29 mm in diameter was easily passed through the anterior orifice. The posterior orifice was closed with running sutures (posterior annulorrhaphy after Hetzer). Before these procedures, we attempted to reconstruct the tricuspid valve with a posterior annulorrhaphy alone; however, valve competence was insufficient. A Sebening stitch was necessary to improve the valve competence. Echocardiography showed TR grade 1 at the patient's discharge from hospital and TR grade 1 to 2 at the follow-up, 10 months after the operation. PMID:22419794

  7. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    PubMed Central

    Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen

  8. Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

    PubMed

    Shi, Yubing; Yeo, Tony Joon Hock; Zhao, Yong; Hwang, Ned H C

    2006-12-01

    Particle Image Velocimetry (PIV) is an important technique in studying blood flow in heart valves. Previous PIV studies of flow around prosthetic heart valves had different research concentrations, and thus never provided the physical flow field pictures in a complete heart cycle, which compromised their pertinence for a better understanding of the valvular mechanism. In this study, a digital PIV (DPIV) investigation was carried out with improved accuracy, to analyse the pulsatile flow field around the bi-leaflet mechanical heart valve (MHV) in a complete heart cycle. For this purpose a pulsatile flow test rig was constructed to provide the necessary in vitro test environment, and the flow field around a St. Jude size 29 bi-leaflet MHV and a similar MHV model were studied under a simulated physiological pressure waveform with flow rate of 5.2 l/min and pulse rate at 72 beats/min. A phase-locking method was applied to gate the dynamic process of valve leaflet motions. A special image-processing program was applied to eliminate optical distortion caused by the difference in refractive indexes between the blood analogue fluid and the test section. Results clearly showed that, due to the presence of the two leaflets, the valvular flow conduit was partitioned into three flow channels. In the opening process, flow in the two side channels was first to develop under the presence of the forward pressure gradient. The flow in the central channel was developed much later at about the mid-stage of the opening process. Forward flows in all three channels were observed at the late stage of the opening process. At the early closing process, a backward flow developed first in the central channel. Under the influence of the reverse pressure gradient, the flow in the central channel first appeared to be disturbed, which was then transformed into backward flow. The backward flow in the central channel was found to be the main driving factor for the leaflet rotation in the valve

  9. [Percutaneously implantable aortic valve: the JenaValve concept evolution].

    PubMed

    Figulla, Hans R; Ferrari, Markus

    2006-10-01

    Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.

  10. Statistical Performance Evaluation Of Soft Seat Pressure Relief Valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Stephen P.; Gross, Robert E.

    2013-03-26

    Risk-based inspection methods enable estimation of the probability of failure on demand for spring-operated pressure relief valves at the United States Department of Energy's Savannah River Site in Aiken, South Carolina. This paper presents a statistical performance evaluation of soft seat spring operated pressure relief valves. These pressure relief valves are typically smaller and of lower cost than hard seat (metal to metal) pressure relief valves and can provide substantial cost savings in fluid service applications (air, gas, liquid, and steam) providing that probability of failure on demand (the probability that the pressure relief valve fails to perform its intendedmore » safety function during a potentially dangerous over pressurization) is at least as good as that for hard seat valves. The research in this paper shows that the proportion of soft seat spring operated pressure relief valves failing is the same or less than that of hard seat valves, and that for failed valves, soft seat valves typically have failure ratios of proof test pressure to set pressure less than that of hard seat valves.« less

  11. Provision, organization and models of heart valve clinics within The United Kingdom.

    PubMed

    Bhattacharyya, S; Pavitt, C; Lloyd, G; Chambers, J B

    2015-02-01

    Specialist clinics are recommended for the assessment and follow-up of patients with heart valve disease. We sought to identify the current provision of specialist valve clinics in UK. A database of all UK National Health Service hospitals was created. An online survey was distributed to each hospital to examine the model of heart valve clinic, patient population, provision of advanced imaging modalities and biochemical markers and provision of patient information services. Valve clinics were run in 48/228 (21%) hospitals, in 27/45 (60%) tertiary centres and 21/183 (11%) district hospitals. The survey was completed by 34 (71%). A consultant cardiologist ran the clinic in 19 (56%), a cardiac sonographer in 8 (24%), a nurse specialist in 3 (9%) and a hybrid model was used in 4 (12%). Patients with native valve disease were seen in 32 (94%), after heart valve surgery in 19 (56%), pre-/post-transcatheter valve intervention in 10 (29%) and with Marfan syndrome in 9(26%). Stress echocardiography, cardiac magnetic resonance imaging, computed tomography and positron emission tomography were available in 21 (62%), 19 (56%), 22 (65%) and 6 (18%) hospitals, respectively. There is an underprovision of specialist heart valve clinics within the UK, and there is a 5-fold difference between cardiac centres and district general hospitals. © The Author 2014. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Bicuspid aortic valve hemodynamics: a fluid-structure interaction study

    NASA Astrophysics Data System (ADS)

    Chandra, Santanu; Seaman, Clara; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV) is a congenital defect in which the aortic valve forms with two leaflets instead of three. While calcific aortic valve disease (CAVD) also develops in the normal tricuspid aortic valve (TAV), its progression in the BAV is more rapid. Although studies have suggested a mechano-potential root for the disease, the native BAV hemodynamics remains largely unknown. This study aimed at characterizing BAV hemodynamics and quantifying the degree of wall-shear stress (WSS) abnormality on BAV leaflets. Fluid-structure interaction models validated with particle-image velocimetry were designed to predict the flow and leaflet dynamics in idealized TAV and BAV anatomies. Valvular function was quantified in terms of the effective orifice area. The regional leaflet WSS was characterized in terms of oscillatory shear index, temporal shear magnitude and temporal shear gradient. The predictions indicate the intrinsic degree of stenosis of the BAV anatomy, reveal drastic differences in shear stress magnitude and pulsatility on BAV and TAV leaflets and confirm the side- and site-specificity of the leaflet WSS. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, these results support the existence of a mechano-etiology of CAVD in the BAV.

  13. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    PubMed

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  14. Studying the Transient Thermal Contact Conductance Between the Exhaust Valve and Its Seat Using the Inverse Method

    NASA Astrophysics Data System (ADS)

    Nezhad, Mohsen Motahari; Shojaeefard, Mohammad Hassan; Shahraki, Saeid

    2016-02-01

    In this study, the experiments aimed at analyzing thermally the exhaust valve in an air-cooled internal combustion engine and estimating the thermal contact conductance in fixed and periodic contacts. Due to the nature of internal combustion engines, the duration of contact between the valve and its seat is too short, and much time is needed to reach the quasi-steady state in the periodic contact between the exhaust valve and its seat. Using the methods of linear extrapolation and the inverse solution, the surface contact temperatures and the fixed and periodic thermal contact conductance were calculated. The results of linear extrapolation and inverse methods have similar trends, and based on the error analysis, they are accurate enough to estimate the thermal contact conductance. Moreover, due to the error analysis, a linear extrapolation method using inverse ratio is preferred. The effects of pressure, contact frequency, heat flux, and cooling air speed on thermal contact conductance have been investigated. The results show that by increasing the contact pressure the thermal contact conductance increases substantially. In addition, by increasing the engine speed the thermal contact conductance decreases. On the other hand, by boosting the air speed the thermal contact conductance increases, and by raising the heat flux the thermal contact conductance reduces. The average calculated error equals to 12.9 %.

  15. Idiopathic mitral valve disease in a patient presenting with Axenfeld-Rieger syndrome.

    PubMed

    Antevil, Jared; Umakanthan, Ramanan; Leacche, Marzia; Brewer, Zachary; Solenkova, Natalia; Byrne, John G; Greelish, James P

    2009-05-01

    A 33-year-old, previously healthy male presented with respiratory distress and underwent intubation. A physical examination revealed a holosystolic murmur and pupillary abnormalities. Echocardiography revealed a flail anterior mitral valve leaflet with ruptured chordae and severe mitral regurgitation. The patient underwent urgent mitral valve replacement and tolerated the procedure well. The mitral valve leaflet was myxomatous and calcified -- an unusual find in such a patient. An ophthalmology consultation was obtained and the patient diagnosed with Axenfeld-Rieger syndrome, a disorder of the anterior ocular chamber that has been associated with cardiac malformations. The present case report adds to the body of literature which suggests a correlation between Axenfeld-Rieger syndrome and valvular abnormalities. Hence, it is believed prudent that patients with Axenfeld-Rieger syndrome should undergo echocardiographic screenings for valvular abnormalities.

  16. Early Outcomes for Valve-in-valve Transcatheter Aortic Valve Replacement in Degenerative Freestyle Bioprostheses.

    PubMed

    Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William

    2017-11-20

    Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  18. Ball valve extractor

    DOEpatents

    Herndon, Charles; Brown, Roger A.

    2002-01-01

    An apparatus and process for removing a ball valve is provided. The ball valve removal tool provides a handle sliding along the length of a shaft. One end of the shaft is secured within an interior cavity of a ball valve while the opposite end of the shaft defines a stop member. By providing a manual sliding force to the handle, the handle impacts the stop member and transmits the force to the ball valve. The direction of the force is along the shaft of the removal tool and disengages the ball valve from the ball valve housing.

  19. Bellows sealed plug valve

    DOEpatents

    Dukas, Jr., Stephen J.

    1990-01-01

    A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.

  20. Check valve installation in pilot operated relief valve prevents reverse pressurization

    NASA Technical Reports Server (NTRS)

    Oswalt, L.

    1966-01-01

    Two check valves prevent reverse flow through pilot-operated relief valves of differential area piston design. Title valves control pressure flow to ensure that the piston dome pressure is always at least as great as the main relief valve discharge pressure.

  1. Transapical aortic valve implantation without angiography: proof of concept.

    PubMed

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  2. A Quantitative Study of Simulated Bicuspid Aortic Valves

    NASA Astrophysics Data System (ADS)

    Szeto, Kai; Nguyen, Tran; Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan

    2010-11-01

    Previous studies have shown that congentially bicuspid aortic valves develop degenerative diseases earlier than the standard trileaflet, but the causes are not well understood. It has been hypothesized that the asymmetrical flow patterns and turbulence found in the bileaflet valves together with abnormally high levels of strain may result in an early thickening and eventually calcification and stenosis. Central to this hypothesis is the need for a precise quantification of the differences in the strain rate levels between bileaflets and trileaflet valves. We present here some in-vitro dynamic measurements of the spatial variation of the strain rate in pig aortic vales conducted in a left ventricular heart flow simulator device. We measure the strain rate of each leaflet during the whole cardiac cycle using phase-locked stereoscopic three-dimensional image surface reconstruction techniques. The bicuspid case is simulated by surgically stitching two of the leaflets in a normal valve.

  3. Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices.

    PubMed

    Hulme, S Elizabeth; Shevkoplyas, Sergey S; Whitesides, George M

    2009-01-07

    This paper describes a method for prefabricating screw, pneumatic, and solenoid valves and embedding them in microfluidic devices. This method of prefabrication and embedding is simple, requires no advanced fabrication, and is compatible with soft lithography. Because prefabrication allows many identical valves to be made at one time, the performance across different valves made in the same manner is reproducible. In addition, the performance of a single valve is reproducible over many cycles of opening and closing: an embedded solenoid valve opened and closed a microfluidic channel more than 100,000 times with no apparent deterioration in its function. It was possible to combine all three types of prefabricated valves in a single microfluidic device to control chemical gradients in a microfluidic channel temporally and spatially.

  4. Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT): a non-surgical method of lung volume reduction.

    PubMed

    Strange, Charlie; Herth, Felix J F; Kovitz, Kevin L; McLennan, Geoffrey; Ernst, Armin; Goldin, Jonathan; Noppen, Marc; Criner, Gerard J; Sciurba, Frank C

    2007-07-03

    Lung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently, less invasive bronchoscopic approaches have been designed to utilize these principles while avoiding the associated perioperative risks. The Endobronchial Valve for Emphysema PalliatioN Trial (VENT) posits that occlusion of a single pulmonary lobe through bronchoscopically placed Zephyr endobronchial valves will effect significant improvements in lung function and exercise tolerance with an acceptable risk profile in advanced emphysema. The trial design posted on Clinical trials.gov, on August 10, 2005 proposed an enrollment of 270 subjects. Inclusion criteria included: diagnosis of emphysema with forced expiratory volume in one second (FEV1) < 45% of predicted, hyperinflation (total lung capacity measured by body plethysmography > 100%; residual volume > 150% predicted), and heterogeneous emphysema defined using a quantitative chest computed tomography algorithm. Following standardized pulmonary rehabilitation, patients were randomized 2:1 to receive unilateral lobar placement of endobronchial valves plus optimal medical management or optimal medical management alone. The co-primary endpoint was the mean percent change in FEV1 and six minute walk distance at 180 days. Secondary end-points included mean percent change in St. George's Respiratory Questionnaire score and the mean absolute changes in the maximal work load measured by cycle ergometry, dyspnea (mMRC) score, and total oxygen use per day. Per patient response rates in clinically significant improvement/maintenance of FEV1 and six minute walk distance and technical success rates of valve placement were recorded. Apriori response predictors based on quantitative CT and lung physiology were defined. If endobronchial valves improve FEV1 and health status with an acceptable safety profile in advanced emphysema, they would offer a novel

  5. The association between gastroesophageal flap valve function and gastroesophageal reflux symptoms.

    PubMed

    Keskin, O; Kalkan, Ç; Yaman, A; Tüzün, A; Soykan, I

    2017-01-01

    Upper gastrointestinal endoscopic examination is usually the first step in the evaluation of patients with suspected gastroesopageal reflux disease. The primary aim of this study was to investigate the association between gastroesophageal flap valve function (GEFV) and gastroesophapgeal reflux symptoms in patients undergoing routine upper endoscopy. Patients and methods: 1507 patients were included into the study and the GEFV graded I to IV as follows: Hill I-II: normal GEFV, and Hill III-IV: abnormal GEFV. Patients in abnormal GEFV group had a higher incidence of reflux symptoms compared to normal GEFV group (53.4% vs 47.4% for heartburn p=0.03 and 53.2% vs 42.4% for regurgitation, p<0.01). In abnormal GEFV patients, esophagitis was more common compared to those with normal GEFV (32.6% vs 11.1%, p<0.01). Presence of heartburn and regurgitation (n =556) correlated with Hill III-IV grades (n = 184/556), (sensitivity: 33%, p = 0.003). In contrast, 24.6% (157/638) of patients without reflux symptoms were in abnormal GEFV group. In patients undergoing endoscopy because of reflux symptoms, Grade III-IV valve was detected more commonly in patients with reflux symptoms compared to patients without reflux symptoms (p = 0.01). Patients with abnormal valves (Hill grades III and IV) but without reflux symptoms, esophagitis and hiatal hernia should be evaluated individually by means of the presence of gastroesophageal reflux disease which means that GEFV is not a good indicator of reflux disease. © Acta Gastro-Enterologica Belgica.

  6. Microfluidic sieve valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  7. Mitral and tricuspid valve surgery in homozygous sickle cell disease: perioperative considerations for a successful outcome.

    PubMed

    Sachithanandan, Anand; Nanjaiah, Prakash; Wright, Christine J; Rooney, Stephen J

    2008-01-01

    Homozygous sickle cell disease (SCD) presents a multitude of challenges in patients undergoing cardiac surgery with cardiopulmonary bypass. Special consideration must be made in such patients and routine practice modified to prevent hypoxia, hypothermia, acidaemia and low-flow states which may potentially trigger a fatal sickling crisis perioperatively. We discuss several perioperative management strategies including a preoperative exchange transfusion, high flow normothermic bypass and warm blood cardioplegia that was utilized in a woman with homozygous SCD who underwent a successful double valve procedure.

  8. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    PubMed

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Sibling cycle piston and valving method

    NASA Technical Reports Server (NTRS)

    Mitchell, Matthew P. (Inventor); Bauwens, Luc (Inventor)

    1990-01-01

    A double-acting, rotating piston reciprocating in a cylinder with the motion of the piston providing the valving action of the Sibling Cycle through the medium of passages between the piston and cylinder wall. The rotating piston contains regenerators ported to the walls of the piston. The piston fits closely in the cylinder at each end of the cylinder except in areas where the wall of the cylinder is relieved to provide passages between the cylinder wall and the piston leading to the expansion and compression spaces, respectively. The piston reciprocates as it rotates. The cylinder and piston together comprise an integral valve that seqentially opens and closes the ports at the ends of the regenerators alternately allowing them to communicate with the expansion space and compression space and blocking that communication. The relieved passages in the cylinder and the ports in the piston are so arranged that each regenerator is sequentially (1) charged with compressed working gas from the compression space; (2) isolated from both expansion and compression spaces; (3) discharged of working gas into the expansion space; and (4) simultaneously charged with working gas from the expansion space while being discharged of working gas into the compression space, in the manner of the Sibling Cycle. In an alterate embodiment, heat exchangers are external to the cylinder and ports in the cylinder wall are alternately closed by the wall of the piston and opened to the expansion and compression spaces through relieved passages in the wall of the reciprocating, rotating piston.

  10. Perivalvular pannus and valve thrombosis: two concurrent mechanisms of mechanical valve prosthesis dysfunction.

    PubMed

    Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María

    2015-02-01

    A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  11. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    PubMed Central

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  12. Vacuum breaker valve assembly

    DOEpatents

    Thompson, J.L.; Upton, H.A.

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening. 1 fig.

  13. Vacuum breaker valve assembly

    DOEpatents

    Thompson, Jeffrey L.; Upton, Hubert Allen

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening.

  14. Zero-leak valve

    NASA Technical Reports Server (NTRS)

    Macglashan, W. F., Jr.

    1980-01-01

    Zero-leakage valve has fluid-sealing diaphragm support and flat sievelike sealing surface. Diaphragm-support valve is easy to fabricate and requires minimum maintenance. Potential applications include isolation valve for waste systems and remote air-actuated valve. Device is also useful in controlling flow of liquid fluorine and corrosive fluids at high pressures.

  15. Aortic valve stenosis and aortic diameters determine the extent of increased wall shear stress in bicuspid aortic valve disease.

    PubMed

    Farag, Emile S; van Ooij, Pim; Planken, R Nils; Dukker, Kayleigh C P; de Heer, Frederiek; Bouma, Berto J; Robbers-Visser, Danielle; Groenink, Maarten; Nederveen, Aart J; de Mol, Bas A J M; Kluin, Jolanda; Boekholdt, S Matthijs

    2018-02-16

    Use of 4-dimensional flow magnetic resonance imaging (4D-flow MRI) derived wall shear stress (WSS) heat maps enables identification of regions in the ascending aorta with increased WSS. These regions are subject to dysregulation of the extracellular matrix and elastic fiber degeneration, which is associated with aortic dilatation and dissection. To evaluate the effect of the presence of aortic valve stenosis and the aortic diameter on the peak WSS and surface area of increased WSS in the ascending aorta. Prospective. In all, 48 bicuspid aortic valve (BAV) patients (38.1 ± 12.4 years) and 25 age- and gender-matched healthy individuals. Time-resolved 3D phase contrast MRI with three-directional velocity encoding at 3.0T. Peak systolic velocity, WSS, and aortic diameters were assessed in the ascending aorta and 3D heat maps were used to identify regions with elevated WSS. Comparisons between groups were performed by t-tests. Correlations were investigated by univariate and multivariate regression analysis. Elevated WSS was present in 15 ± 11% (range; 1-35%) of the surface area of the ascending aorta of BAV patients with aortic valve stenosis (AS) (n = 10) and in 6 ± 8% (range; 0-31%) of the ascending aorta of BAV patients without AS (P = 0.005). The mid-ascending aortic diameter negatively correlated with the peak ascending aortic WSS (R = -0.413, P = 0.004) and the surface area of elevated WSS (R = -0.419, P = 0.003). Multivariate linear regression analysis yielded that the height of peak WSS and the amount of elevated WSS depended individually on the presence of aortic valve stenosis and the diameter of the ascending aorta. The extent of increased WSS in the ascending aorta of BAV patients depends on the presence of aortic valve stenosis and aortic dilatation and is most pronounced in the presence of AS and a nondilated ascending aorta. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 The Authors Journal of

  16. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  17. [Transcatheter aortic valve implantation for aortic stenosis. Initial experience].

    PubMed

    Careaga-Reyna, Guillermo; Lázaro-Castillo, José Luis; Lezama-Urtecho, Carlos Alberto; Macías-Miranda, Enriqueta; Dosta-Herrera, Juan José; Galván Díaz, José

    Aortic stenosis is a frequent disease in the elderly, and is associated with other systemic pathologies that may contraindicate the surgical procedure. Another option for these patients is percutaneous aortic valve implantation, which is less invasive. We present our initial experience with this procedure. Patients with aortic stenosis were included once selection criteria were accomplished. Under general anaesthesia and echocardiographic and fluosocopic control, a transcatheter aortic valve was implanted following s valvuloplasty. Once concluded the procedure, angiographic and pressure control was realized in order to confirm the valve function. Between November 2014 and May 2015, 6 patients were treated (4 males and 2 females), with a mean age of 78.83±5.66 years-old. The preoperative transvalvular gradient was 90.16±28.53mmHg and posterior to valve implant was 3.33±2.92mmHg (P<.05). Two patients had concomitant coronary artery disease which had been treated previously. One patient presented with acute right coronary artery occlusion which was immediately treated. However due to previous renal failure, postoperative sepsis and respiratory failure, the patient died one month later. It was concluded that our preliminary results showed that in selected patients percutaneous aortic valve implantation is a safe procedure with clinical improvement for treated patients. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  18. COX2 Inhibition Reduces Aortic Valve Calcification In Vivo

    PubMed Central

    Wirrig, Elaine E.; Gomez, M. Victoria; Hinton, Robert B.; Yutzey, Katherine E.

    2016-01-01

    Objective Calcific aortic valve disease (CAVD) is a significant cause of morbidity and mortality, which affects approximately 1% of the US population and is characterized by calcific nodule formation and stenosis of the valve. Klotho-deficient mice were used to study the molecular mechanisms of CAVD as they develop robust aortic valve (AoV) calcification. Through microarray analysis of AoV tissues from klotho-deficient and wild type mice, increased expression of the gene encoding cyclooxygenase 2/COX2 (Ptgs2) was found. COX2 activity contributes to bone differentiation and homeostasis, thus the contribution of COX2 activity to AoV calcification was assessed. Approach and Results In klotho-deficient mice, COX2 expression is increased throughout regions of valve calcification and is induced in the valvular interstitial cells (VICs) prior to calcification formation. Similarly, COX2 expression is increased in human diseased AoVs. Treatment of cultured porcine aortic VICs with osteogenic media induces bone marker gene expression and calcification in vitro, which is blocked by inhibition of COX2 activity. In vivo, genetic loss of function of COX2 cyclooxygenase activity partially rescues AoV calcification in klotho-deficient mice. Moreover, pharmacologic inhibition of COX2 activity in klotho-deficient mice via celecoxib-containing diet reduces AoV calcification and blocks osteogenic gene expression. Conclusions COX2 expression is upregulated in CAVD and its activity contributes to osteogenic gene induction and valve calcification in vitro and in vivo. PMID:25722432

  19. Scissor thrust valve actuator

    DOEpatents

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  20. Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices

    PubMed Central

    Hulme, S. Elizabeth; Shevkoplyas, Sergey S.

    2011-01-01

    This paper describes a method for prefabricating screw, pneumatic, and solenoid valves and embedding them in microfluidic devices. This method of prefabrication and embedding is simple, requires no advanced fabrication, and is compatible with soft lithography. Because prefabrication allows many identical valves to be made at one time, the performance across different valves made in the same manner is reproducible. In addition, the performance of a single valve is reproducible over many cycles of opening and closing: an embedded solenoid valve opened and closed a microfluidic channel more than 100,000 times with no apparent deterioration in its function. It was possible to combine all three types of prefabricated valves in a single microfluidic device to control chemical gradients in a microfluidic channel temporally and spatially. PMID:19209338

  1. Thrombogenic potential of transcatheter aortic valve implantation with trivial paravalvular leakage

    PubMed Central

    Siegel, Rolland

    2014-01-01

    Background Significant paravalvular leakage after transcatheter aortic valve implantation (TAVI) correlates with increased morbidity and mortality, but adverse consequences of trivial paravalvular leakage have stimulated few investigations. Using a unique method distinctly different from other diagnostic approaches, we previously reported elevated backflow velocities of short duration (transients) in mechanical valve closure. In this study, similar transients were found in a transcatheter valve paravalvular leakage avatar. Methods Paravalvular leakage rate (zero to 58 mL/second) and aortic valve incompetence (volumetric back flow/forward flow; zero to 32%) were made adjustable using a mock transcatheter aortic valve device and tested in quasi-steady and pulsatile flow test systems. Projected dynamic valve area (PDVA) from the back illuminated mock transcatheter aortic valve device was measured and regional backflow velocities were derived by dividing volumetric flow rate by the PDVA over the open and closing valve phase and the total closed valve area derived from backflow leakage. Results Aortic incompetence from 1-32% generated negative backflow transients from 8 to 267 meters/second, a range not dissimilar to that measured in mechanical valves with zero paravalvular leakage. Optimal paravalvular leakage was identified; not too small generating high backflow transients, not too large considering volume overload and cardiac energy loss caused by defective valve behavior and fluid motion. Conclusions Thrombogenic potential of transcatheter aortic valves with trivial aortic incompetence and high magnitude regional backflow velocity transients was comparable to mechanical valves. This may have relevance to stroke rate, asymptomatic microembolic episodes and indications for anticoagulation therapy after transcatheter valve insertion. PMID:25333018

  2. Transapical transcatheter aortic valve implantation using a new second-generation TAVI system - J-Valve™ for high-risk patients with aortic valve diseases: Initial results with 90-day follow-up.

    PubMed

    Zhu, Da; Chen, Yucheng; Guo, Yingqiang; Hu, Jia; Zhang, Ji; Wei, Xin; Tang, Hong; Shi, Yingkang

    2015-11-15

    To evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis (AS) or pure/dominant aortic regurgitation (AR) using the J-Valve™ system. Twenty patients with isolated aortic valve disease (11 with pure/dominant AR and 9 with AS) at high risk for open-heart surgery were enrolled in this study. The mean Logistic Euro-SCORE I was 27.2±8.2% (mean age 74.5±4.7years). Four sizes of prosthesis were used for annular size up to 21 mm (n=1), 23mm (n=2), 25mm (n=10) and 27mm (n=7). Clinical and echocardiographic evaluations were performed at baseline, post-procedure and follow-up. The primary endpoint was all-cause mortality. Secondary endpoints were procedural success, major adverse events as well as echocardiographic performance. TAVI with the J-Valve™ device was successfully performed in 19 patients (95%). Conversion to surgical valve replacement was necessary in one patient due to prosthesis embolization. No mortality occurred during 90 days follow-up. Pacemaker implantation for new onset conduction disorders was necessary in one patient (5%). For patient with severe AS, post-procedure TAVI resulted in favorable reduction of mean transvalvular gradients (55.3±8.5 vs. 16.4±13.3 mmHg, P<0.01). Mean transvalvular gradient was also favorable in AR patients after valve implantation (6.9±1mmHg). The majority of patients had none or trivial paravalvular regurgitation (17/19) while none had moderate or severe paravalvular regurgitation. Trans-apical TAVI using the J-Valve™ prosthesis is potentially an effective treatment option for patients with AS or pure/dominant AR at high risk for open-heart surgery. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    PubMed

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  4. Plasma and tissue oxidative stress index in patients with rheumatic and degenerative heart valve disease.

    PubMed

    Rabus, Murat; Demirbağ, Recep; Sezen, Yusuf; Konukoğlu, Oğuz; Yildiz, Ali; Erel, Ozcan; Zeybek, Rahmi; Yakut, Cevat

    2008-12-01

    We investigated whether patients with rheumatic and degenerative heart valve disease (HVD) differed with regard to plasma and tissue oxidative stress index (OSI). The study included 56 patients who underwent valve replacement due to rheumatic (n=32; 15 males; mean age 47+/-10 years) and degenerative (n=24; 13 males; mean age 55+/-12 years) HVD. Plasma and tissue total oxidative status (TOS) and total antioxidative capacity (TAC) levels were measured and OSI was calculated. Patients with degenerative HVD had significantly higher age, increased interventricular septum thickness, and higher frequency of aortic stenosis, whereas the incidence of mitral stenosis was higher in patients with rheumatic HVD (p<0.05). Plasma oxidative characteristics did not differ between the two HVD groups (p>0.05). Tissue TAC was significantly lower in patients with rheumatic HVD (p=0.027), whereas tissue TOS and OSI were similar between the two HVD groups (p>0.05). In bivariate analysis, plasma OSI did not show any correlation with clinical, laboratory, and echocardiographic variables (p>0.05). Our data show that plasma and tissue OSI levels are similar in patients with rheumatic and degenerative HVD.

  5. Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices.

    PubMed

    Bezuidenhout, Deon; Williams, David F; Zilla, Peter

    2015-01-01

    Efficient function and long-term durability without the need for anticoagulation, coupled with the ability to be accommodated in many different types of patient, are the principal requirements of replacement heart valves. Although the clinical use of valves appeared to have remained steady for several decades, the evolving demands for the elderly and frail patients typically encountered in the developed world, and the needs of much younger and poorer rheumatic heart disease patients in the developing world have now necessitated new paradigms for heart valve technologies and associated materials. This includes further consideration of durable elastomeric materials. The use of polymers to produce flexible leaflet valves that have the benefits of current commercial bioprosthetic and mechanical valves without any of their deficiencies has been held desirable since the mid 1950s. Much attention has been focused on thermoplastic polyurethanes in view of their generally good physico-chemical properties and versatility in processing, coupled with the improving biocompatibility and stability of recent formulations. Accelerated in vitro durability of between 600 and 1000 million cycles has been achieved using polycarbonate urethanes, and good resistance to degradation, calcification and thrombosis in vivo has been shown with some polysiloxane-based polyurethanes. Nevertheless, polymeric valves have remained relegated to use in temporary ventricular assist devices for bridging heart failure patients to transplantation. Some recent studies suggest that there is a greater degree of instability in thermoplastic materials than hitherto believed so that significant challenges remain in the search for the combination of durability and biocompatibility that would allow polymeric valves to become a clinical reality for surgical implantation. Perhaps more importantly, they could become candidates for use in situations where minimally invasive transcatheter procedures are used to

  6. Pathogenesis of mitral valve disease in mucopolysaccharidosis VII dogs.

    PubMed

    Bigg, Paul W; Baldo, Guilherme; Sleeper, Meg M; O'Donnell, Patricia A; Bai, Hanqing; Rokkam, Venkata R P; Liu, Yuli; Wu, Susan; Giugliani, Roberto; Casal, Margret L; Haskins, Mark E; Ponder, Katherine P

    2013-11-01

    Mucopolysaccharidosis VII (MPS VII) is due to the deficient activity of β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs) in lysosomes and multisystemic disease with cardiovascular manifestations. The goal here was to determine the pathogenesis of mitral valve (MV) disease in MPS VII dogs. Untreated MPS VII dogs had a marked reduction in the histochemical signal for structurally-intact collagen in the MV at 6 months of age, when mitral regurgitation had developed. Electron microscopy demonstrated that collagen fibrils were of normal diameter, but failed to align into large parallel arrays. mRNA analysis demonstrated a modest reduction in the expression of genes that encode collagen or collagen-associated proteins such as the proteoglycan decorin which helps collagen fibrils assemble, and a marked increase for genes that encode proteases such as cathepsins. Indeed, enzyme activity for cathepsin B (CtsB) was 19-fold normal. MPS VII dogs that received neonatal intravenous injection of a gamma retroviral vector had an improved signal for structurally-intact collagen, and reduced CtsB activity relative to that seen in untreated MPS VII dogs. We conclude that MR in untreated MPS VII dogs was likely due to abnormalities in MV collagen structure. This could be due to upregulation of enzymes that degrade collagen or collagen-associated proteins, to the accumulation of GAGs that compete with proteoglycans such as decorin for binding to collagen, or to other causes. Further delineation of the etiology of abnormal collagen structure may lead to treatments that improve biomechanical properties of the MV and other tissues. © 2013.

  7. Pathogenesis of Mitral Valve Disease in Mucopolysaccharidosis VII Dogs

    PubMed Central

    Bigg, Paul W.; Baldo, Guilherme; Sleeper, Meg M.; O'Donnell, Patricia A.; Bai, Hanqing; Rokkam, Venkata R.P.; Liu, Yuli; Wu, Susan; Giugliani, Roberto; Casal, Margret L.; Haskins, Mark E.; Ponder, Katherine P.

    2013-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient activity of β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs) in lysosomes and multisystemic disease with cardiavascular manifestations. The goal here was to determine the pathogenesis of mitral valve (MV) disease in MPS VII dogs. Untreated MPS VII dogs had a marked reduction in the histochemical signal for structurally-intact collagen in the MV at 6 months of age, when mitral regurgitation had developed. Electron microscopy demonstrated that collagen fibrils were of normal diameter, but failed to align into large parallel arrays. mRNA analysis demonstrated a modest reduction in the expression of genes that encode collagen or collagen-associated proteins such as the proteoglycan decorin which helps collagen fibrils assemble, and a marked increase for genes that encode proteases such as cathepsins. Indeed, enzyme activity for cathepsin B (CtsB) was 19-fold normal. MPS VII dogs that received neonatal intravenous injection of a gamma retroviral vector had an improved signal for structurally-intact collagen, and reduced CtsB activity relative to that seen in untreated MPS VII dogs. We conclude that MR in untreated MPS VII dogs was likely due to abnormalities in MV collagen structure. This could be due to upregulation of enzymes that degrade collagen or collagen-associated proteins, to the accumulation of GAGs that compete with proteoglycans such as decorin for binding to collagen, or to other causes. Further delineation of the etiology of abnormal collagen structure may lead to treatments that improve biomechanical properties of the MV and other tissues. PMID:23856419

  8. Water hammer caused by closure of turbine safety spherical valves

    NASA Astrophysics Data System (ADS)

    Karadžić, U.; Bergant, A.; Vukoslavčević, P.

    2010-08-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perućica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  9. Aortic valve repair leads to a low incidence of valve-related complications.

    PubMed

    Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim

    2010-01-01

    Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  10. Radiofrequency Ablation of Left Atrial Reentrant Tachycardias in Rheumatic Mitral Valve Disease: A Case Series.

    PubMed

    Prabhu, Mukund A; Thajudeen, Anees; Vk, Ajit Kumar; J, Tharakan; B V, Prasad Srinivas; Namboodiri, Narayanan

    2017-01-01

    Left atrial (LA) reentrant tachycardias are not uncommon in regions where rheumatic heart disease is prevalent. Some of these arrhythmias may be curable by radiofrequency ablation (RFA). However, there are limited data pertaining to this in existing literature. Three patients who had rheumatic mitral valve disease with past history of surgical-/catheter-based intervention and having no significant residual disease had symptomatic atrial flutter despite optimal medical management. An electrophysiological study confirmed an LA focal/micro-reentrant mechanism in all. There was patchy scarring of the LA, and successful RFA of these arrhythmias could be achieved. The focal nature of the scar in these patients may suggest that the rheumatic involvement of the atrium or the hemodynamic consequence of the vulvar lesion causes nonuniform insult to the atrial tissue and limited scar. At least in some patients with limited scarring, early RFA may help in the maintenance of sinus rhythm. © 2016 Wiley Periodicals, Inc.

  11. Valve

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

  12. High cleanliness globe valve with sine mechanism drive

    NASA Astrophysics Data System (ADS)

    Luo, Hu

    2018-06-01

    This paper gives a new type of quick-opening globe valve for life support pneumatic control system of the safety cabin at underground coal mine. The valve adopts the sine mechanism to transmit the rotating of the handle in the range of 90° to the reciprocating motion of the spool. The mechanism implements the quick-opening function of the valve through controlling the contact and separation between the O-ring and the end face of the valve. Since there is no relative sliding between the sealing interfaces, the valve solute uncontrollable disadvantage wear particles which produced by package ball valve, to ensure high cleanliness in flow path. Traditional transmission mechanism has a reinforcement effect and reduce handle open torque. By the finite element method, the relationship between the contact force and the compression of O-ring is analyzed to provide the boundary condition for the calculation of the rotational torque. Meanwhile the velocity field and pressure field along the flow path are simulated. The caliber size of the valve and the flow resistance coefficient are obtained. There is higher cleanliness, more reliable sealing, smaller handle open torque advantage compared with existing packing ball valve. The above work presents a new technical approach for the design of pneumatic control valve of the safety cabin.

  13. [Longterm results of mitral valve replacement (author's transl)].

    PubMed

    Erhard, W; Reichmann, M; Delius, W; Sebening, H; Herrmann, G

    1977-04-22

    210 patients were followed up by the actuary method for over 5 years after isolated mitral valve replacement or a double valve replacement. After isolated valve replacement the one month survival including the operative mortality was 92+/-2%. The survival after one year was 83+/-3% and after 5 years 66+/-7%. The five year survival of patients in preoperative class III (according to the NYHA) was 73+/-8% and of class IV 57+/-8% (P less than or equal to 0.1). A comparison of valve replacements for pure mitral stenosis or mitral insufficiency showed no statistically significant differences. In the 37 patients who had a double valve replacement the survival risk was not increased in comparison with those patients who had had a single valve replacement. Age above 45 years and a preoperative markedly raised pulmonary arteriolar resistance reduced the chances of survival.

  14. Functional valve assessment: the emerging role of cardiovascular magnetic resonance.

    PubMed

    Shah, Dipan J

    2010-01-01

    The prevalence of valvular heart disease is increasing along with the life span of the population. In assessing individuals with valve disease, echocardiography is the primary imaging modality used by clinicians both for initial assessment and for longitudinal evaluation. Information regarding valve morphology and function, cardiac chamber size, wall thickness, ventricular function, and estimates of pulmonary artery pressures can be readily obtained and integrated to formulate an assessment of valve disease severity. In some instances, body habitus or the presence of coexisting lung disease may result in suboptimal acoustic windows on echocardiography, which may lead to technically difficult studies. Additionally, in some patients, information from clinical history and physical examination or other diagnostic tests may be discordant with echocardiographic findings. In these instances, there is a significant clinical role for cardiovascular magnetic resonance (CMR). The diagnostic capabilities of CMR have increased substantially over the past 20 years due to hardware and software advances. Today, CMR has a number of unique advantages over other imaging modalities - primarily, it provides a view of the entire heart without limitations from inadequate imaging windows or body habitus. Furthermore, CMR can obtain imaging data in any imaging plane prescribed by the scan operator, which makes it ideal for accurate investigation of all cardiac valves - aortic, mitral, pulmonic, and tricuspid. In addition, CMR for valve assessment is noninvasive, free of ionizing radiation, and in most instances does not require contrast administration. Since a comprehensive review of the role of CMR in all valve lesions is beyond the scope of this article, we will focus on the most common valvular indication for performance of clinical CMR techniques and an overview of selected validation and reproducibility studies. The objectives of a comprehensive CMR study for evaluating mitral

  15. Multi-port valve assembly

    DOEpatents

    Guggenheim, S. Frederic

    1986-01-01

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.

  16. Changes in Left Ventricular Morphology and Function After Mitral Valve Surgery

    PubMed Central

    Shafii, Alexis E.; Gillinov, A. Marc; Mihaljevic, Tomislav; Stewart, William; Batizy, Lillian H.; Blackstone, Eugene H.

    2015-01-01

    Degenerative mitral valve disease is the leading cause of mitral regurgitation in North America. Surgical intervention has hinged on symptoms and ventricular changes that develop as compensatory ventricular remodeling takes place. In this study, we sought to characterize the temporal response of left ventricular (LV) morphology and function to mitral valve surgery for degenerative disease, and identify preoperative factors that influence reverse remodeling. From 1986–2007, 2,778 patients with isolated degenerative mitral valve disease underwent valve repair (n=2,607/94%) or replacement (n=171/6%) and had at least 1 postoperative transthoracic echocardiogram (TTE); 5,336 TTEs were available for analysis. Multivariable longitudinal repeated-measures analysis was performed to identify factors associated with reverse remodeling. LV dimensions decreased in the first year after surgery (end-diastolic from 5.7±0.80 to 4.9±1.4 cm; end-systolic from 3.4±0.71 to 3.1±1.4 cm). LV mass index decreased from 139±44 to 112±73 g·m−2. Reduction of LV hypertrophy was less pronounced in patients with greater preoperative left heart enlargement (P<.0001) and greater preoperative LV mass (P<.0001). Postoperative LV ejection fraction initially decreased from 58±7.0 to 53±20, increased slightly over the first postoperative year, and was negatively influenced by preoperative heart failure symptoms (P<.0001) and lower preoperative LV ejection fraction (P<.0001). Risk-adjusted response of LV morphology and function to valve repair and replacement was similar (P>.2). In conclusion, a positive response toward normalization of LV morphology and function after mitral valve surgery is greatest in the first year. The best response occurs when surgery is performed before left heart dilatation, LV hypertrophy, or LV dysfunction develop. PMID:22534055

  17. Microfluidic droplet sorting using integrated bilayer micro-valves

    NASA Astrophysics Data System (ADS)

    Chen, Yuncong; Tian, Yang; Xu, Zhen; Wang, Xinran; Yu, Sicong; Dong, Liang

    2016-10-01

    This paper reports on a microfluidic device capable of sorting microfluidic droplets utilizing conventional bilayer pneumatic micro-valves as sorting controllers. The device consists of two micro-valves placed symmetrically on two sides of a sorting area, each on top of a branching channel at an inclined angle with respect to the main channel. Changes in transmitted light intensity, induced by varying light absorbance by each droplet, are used to divert the droplet from the sorting area into one of the three outlet channels. When no valve is activated, the droplet flows into the outlet channel in the direction of the main channel. When one of the valves is triggered, the flexible membrane of valve will first be deflected. Once the droplet leaves the detection point, the deflected membrane will immediately return to its default flattened position, thereby exerting a drawing pressure on the droplet and deviating it from its original streamline to the outlet on the same side as the valve. This sorting method will be particularly suitable for numerous large-scale integrated microfluidic systems, where pneumatic micro-valves are already used. Only few structural modifications are needed to achieve droplet sorting capabilities in these systems. Due to the mechanical nature of diverting energy applied to droplets, the proposed sorting method may induce only minimal interference to biological species or microorganisms encapsulated inside the droplets that may accompany electrical, optical and magnetic-based techniques.

  18. Should patients with Björk-Shiley valves undergo prophylactic replacement?

    PubMed

    Birkmeyer, J D; Marrin, C A; O'Connor, G T

    1992-08-29

    About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that

  19. Aortic assessment of bicuspid aortic valve patients and their first-degree relatives.

    PubMed

    Straneo, Pablo; Parma, Gabriel; Lluberas, Natalia; Marichal, Alvaro; Soca, Gerardo; Cura, Leandro; Paganini, Juan J; Brusich, Daniel; Florio, Lucia; Dayan, Victor

    2017-03-01

    Background Bicuspid aortic valve patients have an increased risk of aortic dilatation. A deficit of nitric oxide synthase has been proposed as the causative factor. No correlation between flow-mediated dilation and aortic diameter has been performed in patients with bicuspid aortic valves and normal aortic diameters. Being a hereditary disease, we compared echocardiographic features and endothelial function in these patients and their first-degree relatives. Methods Comprehensive physical examinations, routine laboratory tests, transthoracic echocardiography, and measurements of endothelium-dependent and non-dependent flow-mediated vasodilatation were performed in 18 bicuspid aortic valve patients (14 type 1 and 4 type 2) and 19 of their first-degree relatives. Results The first-degree relatives were younger (36.7 ± 18.8 vs. 50.5 ± 13.9 years, p = 0.019) with higher ejection fractions (64.6% ± 1.7% vs. 58.4% ± 9.5%, p = 0.015). Aortic diameters indexed to body surface area were similar in both groups, the except the tubular aorta which was larger in bicuspid aortic valve patients (19.3 ± 2.7 vs. 17.4 ± 2.2 mm·m -2 , p = 0.033). Flow-dependent vasodilation was similar in both groups. A significant inverse correlation was found between non-flow-dependent vasodilation and aortic root diameter in patients with bicuspid aortic valve ( R = -0.57, p = 0.05). Conclusions Bicuspid aortic valve patients without aortopathy have larger ascending aortic diameters than their first-degree relatives. Endothelial function is similar in both groups, and there is no correlation with ascending aorta diameter. Nonetheless, an inverse correlation exists between non-endothelial-dependent dilation and aortic root diameter in bicuspid aortic valve patients.

  20. Differential MicroRNA Expression Profile in Myxomatous Mitral Valve Prolapse and Fibroelastic Deficiency Valves

    PubMed Central

    Chen, Yei-Tsung; Wang, Juan; Wee, Abby S. Y.; Yong, Quek-Wei; Tay, Edgar Lik-Wui; Woo, Chin Cheng; Sorokin, Vitaly; Richards, Arthur Mark; Ling, Lieng-Hsi

    2016-01-01

    Myxomatous mitral valve prolapse (MMVP) and fibroelastic deficiency (FED) are two common variants of degenerative mitral valve disease (DMVD), which is a leading cause of mitral regurgitation worldwide. While pathohistological studies have revealed differences in extracellular matrix content in MMVP and FED, the molecular mechanisms underlying these two disease entities remain to be elucidated. By using surgically removed valvular specimens from MMVP and FED patients that were categorized on the basis of echocardiographic, clinical and operative findings, a cluster of microRNAs that expressed differentially were identified. The expressions of has-miR-500, -3174, -17, -1193, -646, -1273e, -4298, -203, -505, and -939 showed significant differences between MMVP and FED after applying Bonferroni correction (p < 0.002174). The possible involvement of microRNAs in the pathogenesis of DMVD were further suggested by the presences of in silico predicted target sites on a number of genes reported to be involved in extracellular matrix homeostasis and marker genes for cellular composition of mitral valves, including decorin (DCN), aggrecan (ACAN), fibromodulin (FMOD), α actin 2 (ACTA2), extracellular matrix protein 2 (ECM2), desmin (DES), endothelial cell specific molecule 1 (ESM1), and platelet/ endothelial cell adhesion molecule 1 (PECAM1), as well as inverse correlations of selected microRNA and mRNA expression in MMVP and FED groups. Our results provide evidence that distinct molecular mechanisms underlie MMVP and FED. Moreover, the microRNAs identified may be targets for the future development of diagnostic biomarkers and therapeutics. PMID:27213335

  1. Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis.

    PubMed

    Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad

    2018-05-20

    Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.

  2. Reliability and construct validity of the Instrument to Measure the Impact of Valve Heart Disease on the Patient's Daily Life.

    PubMed

    Anjos, Daniela Brianne Martins Dos; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista Dos Santos; Gallani, Maria Cecília Bueno Jayme

    2016-12-19

    evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. avaliar a praticabilidade, aceitabilidade e os efeitos teto e chão, estimar a confiabilidade e verificar a validade de construto convergente do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata em pacientes com valvopatia mitral e/ou aórtica. dados foram obtidos junto a 86 pacientes valvopatas por meio de três etapas: uma entrevista presencial para caracterização sociodemográfica e clínica e as duas outras realizadas por meio de contato telefônico para as aplicações do instrumento (Teste e teste de repetição). quanto à praticabilidade e aceitabilidade, o instrumento foi aplicado com tempo m

  3. Hemodynamics of Pericardial Aortic Valves: Contemporary Stented versus Stentless Valves in a Matched Comparison

    PubMed Central

    Holinski, Sebastian; Zhigalov, Konstantin; Zielinski, Christina Barbara; Grubitzsch, Herko

    2017-01-01

    Purpose: Hemodynamic performance of aortic valve bioprostheses is essential for reliable function and durability. So far, the supra-annularly implanted stentless Sorin Freedom Solo (SFS) demonstrated unsurpassed hemodynamic properties. As contemporary stented and externally mounted pericardial bioprostheses, like the Labcor Dokimos Plus (LDP), also improve hemodynamic performance, these types of valves were compared in this study. Methods: A total of 218 patients, who underwent aortic valve replacement with the LDP or the SFS, were matched retrospectively 1:1 on variables affecting hemodynamic measurements: implanted valve size, age, sex, and body surface area (BSA). With matching tolerance for valve size and gender of 0%, for age and BSA of 5%, 57 patient-pairs were yielded. Operative data, clinical, and hemodynamic outcome were analyzed. Results: Except for slightly higher left ventricular function and lower procedural times in the SFS group, preoperative, operative, and postoperative characteristics of patient-pairs did not differ significantly. Mean pressure gradients, effective orifice areas (EOAs), and indexed EOAs were comparable. Corresponding to valve sizes of 21, 23, 25, and 27 mm, the indexed EOAs of the LDP and SFS prostheses were 1.08 ± 0.33, 0.92 ± 0.19, 0.93 ± 0.24, 0.99 ± 0.13 cm2/m2 and 0.81 ± 0.13, 0.92 ± 0.28, 0.95 ± 0.20, 1.04 ± 0.27 cm2/m2, respectively. Conclusion: Contemporary stented and stentless pericardial bioprostheses showed excellent hemodynamic properties without significant differences in EOAs and indexed EOAs. PMID:28890465

  4. Magnetically operated check valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G. (Inventor); Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  5. Magnetically operated check valve

    NASA Astrophysics Data System (ADS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  6. Aortic valve repair using a differentiated surgical strategy.

    PubMed

    Langer, Frank; Aicher, Diana; Kissinger, Anke; Wendler, Olaf; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-09-14

    Reconstruction of the aortic valve for aortic regurgitation (AR) remains challenging, in part because of not only cusp or root pathology but also a combination of both can be responsible for this valve dysfunction. We have systematically tailored the repair to the individual pathology of cusps and root. Between October 1995 and August 2003, aortic valve repair was performed in 282 of 493 patients undergoing surgery for AR and concomitant disease. Root dilatation was corrected by subcommissural plication (n=59), supracommissural aortic replacement (n=27), root remodeling (n=175), or valve reimplantation within a graft (n=24). Cusp prolapse was corrected by plication of the free margin (n=157) or triangular resection (n =36), cusp defects were closed with a pericardial patch (n=16). Additional procedures were arch replacement (n=114), coronary artery bypass graft (n=60) or mitral repair (n=24). All patients were followed-up (follow-up 99.6% complete), and cumulative follow-up was 8425 patient-months (mean, 33+/-27 months).Results- Eleven patients died in hospital (3.9%). Nine patients underwent reoperation for recurrent AR (3.3%). Actuarial freedom from AR grade > or =II at 5 years was 81% for isolated valve repair, 84% for isolated root replacement, and 94% for combination of both; actuarial freedom from reoperation at 5 years was 93%, 95%, and 98%, respectively. No thromboembolic events occurred, and there was 1 episode of endocarditis 4.5 years postoperatively. Aortic valve repair is feasible even for complex mechanisms of AR with a systematic and individually tailored approach. Operative mortality is low and mid-term durability is encouraging. The incidence of valve-related morbidity is low compared with valve replacement.

  7. Quality of Life and Anxiety in Younger Patients after Biological versus Mechanical Aortic Valve Replacement.

    PubMed

    Kottmaier, Marc; Hettich, Ina; Deutsch, Marcus-André; Badiu, Catalin; Krane, Markus; Lange, Ruediger; Bleiziffer, Sabine

    2017-04-01

    Background  Since biological valve recipients are likely to need a redo procedure in the future for valve deterioration, we hypothesized patients might be more fearful about the progression of their disease than patients after aortic valve replacement (AVR) with a mechanical valve. The aim of this study is to compare the quality of life (QOL) and anxiety in patients who have undergone biological versus mechanical AVR. Method  A total of 56 patients after mechanical AVR (mean age: 64.4 ± 8.17 years) and 66 patients after biological AVR (mean age: 64.8 ± 11.05 years) received three questionnaires 5.66 (± 2.68) years after surgery, including: The short form-36 (SF-36) to assess QOL, the fear of progression questionnaire (FOP), and the cardiac anxiety questionnaire (CAQ) to assess general anxiety, anxiety related to cardiac symptoms, and anxiety about progression of heart disease and valve and anticoagulation-specific questions. Results  No significant differences were found for all categories of the SF-36. The FOP showed significantly favorable values for the biological AVR group. The CAQ showed a tendency in the subscale "avoidance" (i.e., avoidance of pulse increase) and "attention" towards more favorable values for the biological AVR group. Conclusions  In contrast to our hypothesis, patients after mechanical AVR show significantly higher anxiety values for the FOP, and a tendency toward higher values for "avoidance" (i.e., avoidance of pulse increase). Partnership concerns, especially in terms of sexuality can be explained by factors that are recognizable for the partner, such as valve sound. These data provide evidence that factors that are continuously present after mechanical AVR, such as valve sound or anticoagulation might affect wellbeing stronger than the certainty of reoperation in the future after biological AVR. We conclude that implantation of a biological prosthesis can be justified in younger patients with regards to QOL. Georg

  8. Mitral annular calcification in patients undergoing aortic valve replacement for aortic valve stenosis.

    PubMed

    Takami, Yoshiyuki; Tajima, Kazuyoshi

    2016-02-01

    Limited data exis t on clinical relevance of aortic valve stenosis (AVS) and mitral annular calcification (MAC), although with similar pathophysiologic basis. We sought to reveal the prevalence of MAC and its clinical features in the patients undergoing aortic valve replacement (AVR) for AVS. We reviewed 106 consecutive patients who underwent isolated AVR from 2004 to 2010. Before AVR, CT scans were performed to identify MAC, whose severity was graded on a scale of 0-4, with grade 0 denoting no MAC and grade 4 indicating severe MAC. Echocardiography was performed before AVR and at follow-up over 2 years after AVR. MAC was identified in 56 patients with grade 1 (30 %), 2 (39 %), 3 (18 %), and 4 (13 %), respectively. Patients with MAC presented older age (72 ± 8 versus 66 ± 11 years), higher rate of dialysis-dependent renal failure (43 versus 4 %), and less frequency of bicuspid aortic valve (9 versus 36 %), when compared to those without MAC. No significant differences were seen in short- and mid-term mortality after AVR between the groups. In patients with MAC, progression of neither mitral regurgitation nor stenosis was observed at follow-up of 53 ± 23 months for 102 survivors, although the transmitral flow velocities were higher than in those without MAC. In conclusion, MAC represented 53 % of the patients undergoing isolated AVR for AVS, usually appeared in dialysis-dependent elder patients with tricuspid AVS. MAC does not affect adversely upon the survival, without progression of mitral valve disease, at least within 2 years after AVR.

  9. Veterinary Medicine and Multi-Omics Research for Future Nutrition Targets: Metabolomics and Transcriptomics of the Common Degenerative Mitral Valve Disease in Dogs.

    PubMed

    Li, Qinghong; Freeman, Lisa M; Rush, John E; Huggins, Gordon S; Kennedy, Adam D; Labuda, Jeffrey A; Laflamme, Dorothy P; Hannah, Steven S

    2015-08-01

    Canine degenerative mitral valve disease (DMVD) is the most common form of heart disease in dogs. The objective of this study was to identify cellular and metabolic pathways that play a role in DMVD by performing metabolomics and transcriptomics analyses on serum and tissue (mitral valve and left ventricle) samples previously collected from dogs with DMVD or healthy hearts. Gas or liquid chromatography followed by mass spectrophotometry were used to identify metabolites in serum. Transcriptomics analysis of tissue samples was completed using RNA-seq, and selected targets were confirmed by RT-qPCR. Random Forest analysis was used to classify the metabolites that best predicted the presence of DMVD. Results identified 41 known and 13 unknown serum metabolites that were significantly different between healthy and DMVD dogs, representing alterations in fat and glucose energy metabolism, oxidative stress, and other pathways. The three metabolites with the greatest single effect in the Random Forest analysis were γ-glutamylmethionine, oxidized glutathione, and asymmetric dimethylarginine. Transcriptomics analysis identified 812 differentially expressed transcripts in left ventricle samples and 263 in mitral valve samples, representing changes in energy metabolism, antioxidant function, nitric oxide signaling, and extracellular matrix homeostasis pathways. Many of the identified alterations may benefit from nutritional or medical management. Our study provides evidence of the growing importance of integrative approaches in multi-omics research in veterinary and nutritional sciences.

  10. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  11. A versatile valving toolkit for automating fluidic operations in paper microfluidic devices.

    PubMed

    Toley, Bhushan J; Wang, Jessica A; Gupta, Mayuri; Buser, Joshua R; Lafleur, Lisa K; Lutz, Barry R; Fu, Elain; Yager, Paul

    2015-03-21

    Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically after a) a certain period of time, or b) the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 μl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50 s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods - both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device.

  12. Transapical aortic valve implantation and minimally invasive off-pump bypass surgery

    PubMed Central

    Ahad, Samir; Baumbach, Hardy; Hill, Stephan; Franke, Ulrich F. W.

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) has gained increasing popularity for high-risk patients with symptomatic aortic valve stenosis. A concomitant coronary artery disease leads to a complicated management and an increased perioperative risk. This case report describes the successful total arterial coronary revascularization of the left anterior descending and the left marginal branch of the circumflex artery utilizing the left internal mammary artery (LIMA) and left radial artery in off-pump technique in combination with the transapical transcatheter aortic valve implantation via minimally invasive anterolateral access in the fifth intercostal space. PMID:24221960

  13. Transcatheter aortic valve implantation using anatomically oriented, marrow stromal cell-based, stented, tissue-engineered heart valves: technical considerations and implications for translational cell-based heart valve concepts.

    PubMed

    Emmert, Maximilian Y; Weber, Benedikt; Behr, Luc; Sammut, Sebastien; Frauenfelder, Thomas; Wolint, Petra; Scherman, Jacques; Bettex, Dominique; Grünenfelder, Jürg; Falk, Volkmar; Hoerstrup, Simon P

    2014-01-01

    While transcatheter aortic valve implantation (TAVI) has rapidly evolved for the treatment of aortic valve disease, the currently used bioprostheses are prone to continuous calcific degeneration. Thus, autologous, cell-based, living, tissue-engineered heart valves (TEHVs) with regeneration potential have been suggested to overcome these limitations. We investigate the technical feasibility of combining the concept of TEHV with transapical implantation technology using a state-of-the-art transcatheter delivery system facilitating the exact anatomical position in the systemic circulation. Trileaflet TEHVs fabricated from biodegradable synthetic scaffolds were sewn onto self-expanding Nitinol stents seeded with autologous marrow stromal cells, crimped and transapically delivered into the orthotopic aortic valve position of adult sheep (n = 4) using the JenaValve transapical TAVI System (JenaValve, Munich, Germany). Delivery, positioning and functionality were assessed by angiography and echocardiography before the TEHV underwent post-mortem gross examination. For three-dimensional reconstruction of the stent position of the anatomically oriented system, a computed tomography analysis was performed post-mortem. Anatomically oriented, transapical delivery of marrow stromal cell-based TEHV into the orthotopic aortic valve position was successful in all animals (n = 4), with a duration from cell harvest to TEHV implantation of 101 ± 6 min. Fluoroscopy and echocardiography displayed sufficient positioning, thereby entirely excluding the native leaflets. There were no signs of coronary obstruction. All TEHV tolerated the loading pressure of the systemic circulation and no acute ruptures occurred. Animals displayed intact and mobile leaflets with an adequate functionality. The mean transvalvular gradient was 7.8 ± 0.9 mmHg, and the mean effective orifice area was 1.73 ± 0.02 cm(2). Paravalvular leakage was present in two animals, and central aortic regurgitation due to a

  14. Clinical Implication of Transaortic Mitral Pannus Removal During Repeat Cardiac Surgery for Patients With Mechanical Mitral Valve.

    PubMed

    Park, Byungjoon; Sung, Kiick; Park, Pyo Won

    2018-01-25

    This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (P<0.001). No mechanical valve malfunction was apparent on last echocardiography. TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.

  15. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  16. Automatic shutoff valve

    NASA Technical Reports Server (NTRS)

    Hawkins, S. F.; Overbey, C. W.

    1980-01-01

    Cellulose-sponge disk absorbs incoming water and expands with enough force to shut valve. When water recedes, valve opens by squeezing sponge dry to its original size. This direct mechanical action is considered more reliable than solenoid valve.

  17. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    PubMed

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Overflow control valve

    DOEpatents

    Hundal, Rolv; Kessinger, Boyd A.; Parlak, Edward A.

    1984-07-24

    An overflow control valve for use in a liquid sodium coolant pump tank which valve can be extended to create a seal with the pump tank wall or retracted to break the seal thereby accommodating valve removal. An actuating shaft which controls valve disc position also has cams which bear on roller surfaces to force retraction of a sliding cylinder against spring tension to retract the cylinder from sealing contact with the pump tank.

  19. Aerodynamic Shutoff Valve

    NASA Technical Reports Server (NTRS)

    Horstman, Raymond H.

    1992-01-01

    Aerodynamic flow achieved by adding fixed fairings to butterfly valve. When valve fully open, fairings align with butterfly and reduce wake. Butterfly free to turn, so valve can be closed, while fairings remain fixed. Design reduces turbulence in flow of air in internal suction system. Valve aids in development of improved porous-surface boundary-layer control system to reduce aerodynamic drag. Applications primarily aerospace. System adapted to boundary-layer control on high-speed land vehicles.

  20. Mesofluidic two stage digital valve

    DOEpatents

    Jansen, John F; Love, Lonnie J; Lind, Randall F; Richardson, Bradley S

    2013-12-31

    A mesofluidic scale digital valve system includes a first mesofluidic scale valve having a valve body including a bore, wherein the valve body is configured to cooperate with a solenoid disposed substantially adjacent to the valve body to translate a poppet carried within the bore. The mesofluidic scale digital valve system also includes a second mesofluidic scale valve disposed substantially perpendicular to the first mesofluidic scale valve. The mesofluidic scale digital valve system further includes a control element in communication with the solenoid, wherein the control element is configured to maintain the solenoid in an energized state for a fixed period of time to provide a desired flow rate through an orifice of the second mesofluidic valve.

  1. A nonintrusive method for measuring the operating temperature of a solenoid-operated valve

    NASA Astrophysics Data System (ADS)

    Kryter, Robert C.

    Experimental data are presented to show that the in-service operating temperature of a solenoid operated valve (SOV) can be inferred simply and nondisruptively by using the copper winding of the solenoid coil as a self-indicating, permanently available resistance thermometer. The principal merits of this approach include: (1) there is no need for an add-on temperature sensor, (2) the true temperature of a critical and likely the hottest, part of the SOV (namely, the electrical coil) is measured directly, (3) temperature readout can be provided at any location at which the SOV electrical lead wires are accessible (even though remote from the valve), (4) the SOV need not be disturbed (whether normally energized or deenergized) to measure its temperature in situ, and (5) the method is applicable to all types of SOVs, large and small, ac- and dc-powered. Laboratory tests comparing temperatures measured both by coil resistance and by a conventional thermometer placed in contact with the external surface of the potted solenoid coil indicate that temperature within the coil may be on the order of 40 C higher than that measured externally, a fact that is important to life-expectancy calculations made on the basis of Arrhenius theory. Field practicality is illustrated with temperature measurements made using this method on a SOV controlling the flow of refrigerant in a large chilled-water air-conditioning system.

  2. Main Oxidizer Valve Design

    NASA Technical Reports Server (NTRS)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  3. Slow opening valve. [valve design for shuttle portable oxygen system

    NASA Technical Reports Server (NTRS)

    Drapeau, D. F. (Inventor)

    1984-01-01

    A valve control is described having a valve body with an actuator stem and a rotating handle connected to the actuator stem by a differential drive mechanism which, during uniform movement of the handle in one direction, initially opens the valve at a relatively slow rate and, thereafter, complete the valve movement at a substantially faster rate. A series of stop rings are received about the body in frictional abutting relationship and serially rotated by the handle to uniformly resist handle movement independently of the extent of handle movement.

  4. Pathological Investigation of Congenital Bicuspid Aortic Valve Stenosis, Compared with Atherosclerotic Tricuspid Aortic Valve Stenosis and Congenital Bicuspid Aortic Valve Regurgitation

    PubMed Central

    Hamatani, Yasuhiro; Ishibashi-Ueda, Hatsue; Nagai, Toshiyuki; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Fujita, Tomoyuki; Kobayashi, Junjiro; Anzai, Toshihisa

    2016-01-01

    Background Congenital bicuspid aortic valve (CBAV) is the main cause of aortic stenosis (AS) in young adults. However, the histopathological features of AS in patients with CBAV have not been fully investigated. Methods and Results We examined specimens of aortic valve leaflets obtained from patients who had undergone aortic valve re/placement at our institution for severe AS with CBAV (n = 24, CBAV-AS group), severe AS with tricuspid aortic valve (n = 24, TAV-AS group), and severe aortic regurgitation (AR) with CBAV (n = 24, CBAV-AR group). We compared the histopathological features among the three groups. Pathological features were classified using semi-quantitative methods (graded on a scale 0 to 3) by experienced pathologists without knowledge of the patients’ backgrounds. The severity of inflammation, neovascularization, and calcium and cholesterol deposition did not differ between the CBAV-AS and TAV-AS groups, and these four parameters were less marked in the CBAV-AR group than in the CBAV-AS (all p<0.01). Meanwhile, the grade of valvular fibrosis was greater in the CBAV-AS group, compared with the TAV-AS and CBAV-AR groups (both p<0.01). In AS patients, thickness of fibrotic lesions was greater on the aortic side than on the ventricular side (both p<0.01). Meanwhile, thickness of fibrotic lesions was comparable between the aortic and ventricular sides in CBAV-AR patients (p = 0.35). Conclusions Valvular fibrosis, especially on the aortic side, was greater in patients with CBAV-AS than in those without, suggesting a difference in the pathogenesis of AS between CBAV and TAV. PMID:27479126

  5. Lightweight Motorized Valve

    NASA Technical Reports Server (NTRS)

    Gonzalez, R.; Vandewalle, J.

    1986-01-01

    Redesigned actuator assembly weighs 50 percent less. Isolator valve operated by ac motor instead of usual dc solenoid. Valve weighs only 3 lb (1.4 kg). New valve functions with either two-phase or three-phase power. Developed for isolating fluids in propellant tanks, manifolds, and interconnecting lines of Space Shuttle reaction control and orbital maneuvering subsystems, valve suited to applications in which leakage must be kept to minimum at high pressure differences - in petroleum and chemical processing.

  6. Computational analysis of an aortic valve jet

    NASA Astrophysics Data System (ADS)

    Shadden, Shawn C.; Astorino, Matteo; Gerbeau, Jean-Frédéric

    2009-11-01

    In this work we employ a coupled FSI scheme using an immersed boundary method to simulate flow through a realistic deformable, 3D aortic valve model. This data was used to compute Lagrangian coherent structures, which revealed flow separation from the valve leaflets during systole, and correspondingly, the boundary between the jet of ejected fluid and the regions of separated, recirculating flow. Advantages of computing LCS in multi-dimensional FSI models of the aortic valve are twofold. For one, the quality and effectiveness of existing clinical indices used to measure aortic jet size can be tested by taking advantage of the accurate measure of the jet area derived from LCS. Secondly, as an ultimate goal, a reliable computational framework for the assessment of the aortic valve stenosis could be developed.

  7. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    PubMed

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. A versatile valving toolkit for automating fluidic operations in paper microfluidic devices

    PubMed Central

    Toley, Bhushan J.; Wang, Jessica A.; Gupta, Mayuri; Buser, Joshua R.; Lafleur, Lisa K.; Lutz, Barry R.; Fu, Elain; Yager, Paul

    2015-01-01

    Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically a) after a certain period of time, or b) after the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 μl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods – both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device. PMID:25606810

  9. Operational durability of a giant ER valve for Braille display

    NASA Astrophysics Data System (ADS)

    Luning, Xu; Han, Li; Yufei, Li; Shen, Rong; Kunquan, Lu

    2017-05-01

    The compact configuration of giant ER (electrorheological) valves provides the possibility of realizing a full-page Braille display. The operational durability of ER valves is a key issue in fulfilling a Braille display. A giant ER valve was used to investigate the variations in pressure drops and critical pressure drops of the valves over a long period under some typical operational parameters. The results indicate that neither the pressure drops nor critical pressure drops of giant ER valves show apparent deterioration over a long period. Without ER fluid exchange, a blockage appears in the channel of the valve because the ER structures induced by an external electric field cannot be broken by the Brownian motion of hydraulic oil molecules when the external electric field is removed. Forcing ER fluid flow is an effective and necessary method to keep the channel of the valve unblocked. Thus the operational durability of the valve using giant ER fluids is able to meet the demands of Braille display.

  10. Antiphospholipid antibody-associated non-infective mitral valve endocarditis successfully treated with medical therapy.

    PubMed

    Contractor, Tahmeed; Bell, Adrian; Khasnis, Atul; Silverberg, Bruce J; Martinez, Matthew W

    2013-01-01

    Non-bacterial endocarditis lesions associated with antiphospholipid antibodies (aPLs) in the absence of other criteria for antiphospholipid syndrome or systemic lupus erythematosus is termed an aPL-associated cardiac valve disease. Evidence regarding the management of this condition is sparse. A rare case is described of a 20-year-old female who presented with an incidental finding of 'vegetations on a heart valve'. Echocardiography revealed mitral valve leaflet thickening and echodensities with moderate mitral regurgitation. She had an elevated partial thromboplastin time that did not correct with a mixing study, and elevated levels of antiocardiolipin antibodies. Hence, a diagnosis of aPL-associated cardiac valve disease was made, and the patient commenced on warfarin, hydroxychloroquine, and a short course of oral prednisone. At one year after diagnosis the patient remained symptom-free, and follow up echocardiography revealed resolution of the vegetations with minimal mitral regurgitation. Further evidence is needed to guide the therapy of this rare condition.

  11. Kangaroo versus porcine aortic valve tissue--valve geometry morphology, tensile strength and calcification potential.

    PubMed

    Neethling, W M; Papadimitriou, J M; Swarts, E; Hodge, A J

    2000-06-01

    Valve related factors and patient related factors are responsible for calcification of valvular bioprostheses. Recent studies showed different donor and recipient species have different influences on the total calcification rate of bioprostheses. This study was performed to evaluate and compare Kangaroo aortic valve leaflets with porcine aortic valve leaflets. Experimental design. Prospective study. Setting. Cardio-thoracic experimental research of a university department. Glutaraldehyde-fixed Kangaroo and porcine valve leaflets were evaluated in vitro according to valve geometry (internal diameter and leaflet thickness), morphology (light and electron microscopy) and tensile strength. In vivo evaluation consisted of implantation in a rat model for 8 weeks, Von Kossa stain for calcium and atomic absorption spectrophotometry for total extractable calcium content. Kangaroo valves indicated a smaller internal valve diameter as well as a thinner valve leaflet (p<0.01, ANOVA) at corresponding body weight, less proteoglycan spicules in the fibrosa, increased elasticity (p<0.05) and low calcification potential (p<0.01, confidence interval 95%). Kangaroo aortic valve leaflets have different valvular qualities compared to porcine valve tissue. Kangaroo valve leaflets are significantly superior to porcine valve leaflets as far as calcification is concerned. These results are encouraging and suggest further in vivo evaluation in a larger animal model before clinical application can be considered.

  12. What Is Heart Valve Surgery?

    MedlinePlus

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  13. Valve repair in aortic regurgitation without root dilatation--aortic valve repair.

    PubMed

    Lausberg, H F; Aicher, D; Kissinger, A; Langer, F; Fries, R; Schäfers, H-J

    2006-02-01

    Aortic valve repair was established in the context of aortic root remodeling. Variable results have been reported for isolated valve repair. We analyzed our experience with isolated valve repair and compared the results with those of aortic root remodeling. Between October 1995 and August 2003, isolated repair of the aortic valve was performed in 83 patients (REP), remodeling of the aortic valve in 175 patients (REMO). The demographics of the two groups were comparable (REP: mean age 54.4 +/- 20.7 yrs, male-female ratio 2.1 : 1; REMO: mean age 60.8 +/- 13.6 yrs, male-female ratio 2.4 : 1; p = ns). In both groups the number of bicuspid valves was comparable (REP: 41 %, REMO: 32 %; p = ns). All patients were followed by echocardiography for a cumulative follow-up of 8204 patient months (mean 32 +/- 23 months). Overall in-hospital mortality was 2.4 % in REP and 4.6 % in REMO ( p = 0.62). Systolic gradients were comparable in both groups (REP: 5.8 +/- 2.2, REMO: 6.5 +/- 3.1 mm Hg, p = 0.09). The mean degree of aortic regurgitation 12 months postoperatively was 0.8 +/- 0.7 after REP and 0.7 +/- 0.7 after REMO ( p = 0.29). Freedom from significant regurgitation (> or = II degrees ) after 5 years was 86 % in REP and 89 % in REMO ( p = 0.17). Freedom from re-operation after 5 years was 94.4 % in REP and 98.2 % in REMO ( p = 0.33). Aortic regurgitation without concomitant root dilatation can be treated effectively by aortic valve repair. The functional results are equivalent to those obtained with valve-preserving root replacement. Aortic valve repair appears to be an alternative to valve replacement in aortic regurgitation.

  14. Medium-term outcome of Toronto aortic valve replacement: single center experience.

    PubMed

    Li, Wei; Price, Susanna; O'Sullivan, Christine A; Kumar, Pankaj; Jin, Xu Y; Henein, Michael Y; Pepper, John R

    2008-09-26

    Long-term competence of any aortic prosthesis is critical to its clinical durability. Bioprosthetic valves, and in particular the stentless type have been proposed to offer superior haemodynamic profiles with consequent potential for superior left-ventricular mass regression. These benefits however are balanced by the potential longevity of the implanted valve. The aims of this study were to assess medium-term Toronto aortic valve function and its effect on left-ventricular function. Between 1992 and 1996 86 patients underwent Toronto aortic valve replacement for aortic valve disease and were followed up annually. Prospectively collected data was analyzed for all patients where detailed echocardiographic follow-up was available. Echocardiographic studies were analyzed at 2+/-0.6 and 6+/-1.4 years after valve replacement. Data collected included left-ventricular systolic and diastolic dimensions, fractional shortening and left-ventricular mass. In addition, data on aortic valve and root morphology, peak aortic velocities, time velocity integral, stroke volume and the mechanism of valve failure where relevant, were also collected. Complete echocardiographic data were available for eighty-four patients, age 69+/-9 years, 62 male. Additional coronary artery bypass grafting was performed in 38% of patients. Twelve (14%) valves had failed during follow-up, 7 (8%) requiring re-operation. Valve failure was associated with morphologically bicuspid native aortic valve (9/12), and progressive dilatation of the aortic sinuses, sino-tubular junction and ascending aorta (11/12). Left-ventricular mass index remained high (184+/-75 g/m(2)) and did not continue to regress between early and medium-term follow-up (175.8+/-77 g/m(2)). Although more than 90% of implanted Toronto aortic valves remained haemodynamically stable with low gradient at medium-term follow-up, young age and larger aortic dimensions in patients with valve failure suggest better outcome if used in the elderly

  15. Perceval S aortic valve implantation in an achondroplastic Dwarf

    PubMed Central

    Baikoussis, Nikolaos G.; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography. PMID:26750695

  16. Face-Sealing Butterfly Valve

    NASA Technical Reports Server (NTRS)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  17. Incremental value of live/real time three-dimensional transthoracic echocardiography over the two-dimensional technique in assessing carcinoid heart disease involving the aortic valve.

    PubMed

    Bulur, Serkan; Hsiung, Ming C; Nanda, Navin C; Hardas, Shalaka; Mohamed, Ahmed; ElKaryoni, Ahmed; Srialluri, Swetha; Barssoum, Kirolos; Elsayed, Mahmoud; Wei, Jeng; Yin, Wei-Hsian

    2016-11-01

    We present a case of an adult with metastatic carcinoid heart disease, in whom live/real time three-dimensional transthoracic echocardiography provided incremental value over two-dimensional transthoracic echocardiography in assessing involvement of the aortic valve. © 2016, Wiley Periodicals, Inc.

  18. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    PubMed

    O' Sullivan, Katie E; Casserly, Ivan; Hurley, John

    2015-04-01

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  19. 3T magnetic resonance imaging testing of externally programmable shunt valves

    PubMed Central

    Zabramski, Joseph M.; Preul, Mark C.; Debbins, Josef; McCusker, Daniel J.

    2012-01-01

    Background: Exposure of externally programmable shunt-valves (EPS-valves) to magnetic resonance imaging (MRI) may lead to unexpected changes in shunt settings, or affect the ability to reprogram the valve. We undertook this study to examine the effect of exposure to a 3T MRI on a group of widely used EPS-valves. Methods: Evaluations were performed on first generation EPS-valves (those without a locking mechanism to prevent changes in shunt settings by external magnets other than the programmer) and second generation EPS-valves (those with a locking mechanisms). Fifteen new shunt-valves were divided into five groups of three identical valves each, and then exposed to a series of six simulated MRI scans. After each of the exposures, the valves were evaluated to determine if the valve settings had changed, and whether the valves could be reprogrammed. The study produced 18 evaluations for each line of shunt-valves. Results: Exposure of the first generation EPS-valves to a 3T magnetic field resulted in frequent changes in the valve settings; however, all valves retained their ability to be reprogrammed. Repeated exposure of the second generation EPS-valves has no effect on shunt valve settings, and all valves retained their ability to be interrogated and reprogrammed. Conclusions: Second generation EPS-valves with locking mechanisms can be safely exposed to repeated 3T MRI systems, without evidence that shunt settings will change. The exposure of the first generation EPS-valves to 3T MRI results in frequent changes in shunt settings that necessitate re-evaluation soon after MRI to avoid complications. PMID:22937481

  20. Magnetically operated check valve

    NASA Astrophysics Data System (ADS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1993-03-01

    A magnetically operated check valve is disclosed having, in one aspect, a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  1. Fast acting check valve

    NASA Technical Reports Server (NTRS)

    Perkins, Gerald S. (Inventor)

    1979-01-01

    A check valve which closes more rapidly to prevent wearing of the valve seat and of the valve member that seals thereagainst, including a solenoid or other actuator that aids the normal spring to quickly close the valve at approximately the time when downpath fluid flow would stop, the actuator then being deenergized. The control circuit that operates the actuator can include a pair of pressure sensors sensing pressure both upstream and downstream from the valve seat. Where the valve is utilized to control flow to or from a piston pump, energization of the actuator can be controlled by sensing when the pump piston reaches its extreme of travel.

  2. Evaluation of mitral valve replacement anchoring in a phantom

    NASA Astrophysics Data System (ADS)

    McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.

    2012-02-01

    Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.

  3. Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.

    PubMed

    Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi

    2013-09-10

    Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.

  4. Double-orifice mitral valve associated with bicuspid aortic valve.

    PubMed

    Khani, Mohammad; Rohani, Atoosheh

    2017-06-01

    Double-orifice mitral valve is a rare congenital anomaly that usually does not cause a significant hemodynamic effect. Double-orifice mitral valve and a bicuspid aortic valve were detected in a 54-year-old lady who presented with dyspnea on exertion for one year. This is a rare association. Three-dimensional echocardiography is helpful to determine the type of malformation. The patient had no significant mitral regurgitation or stenosis, but demonstrated moderate aortic stenosis. She is undergoing periodic monitoring.

  5. Aortic Valve Replacement for Moderate Aortic Stenosis with Severe Calcification and Left Ventricualr Dysfunction-A Case Report and Review of the Literature.

    PubMed

    Narang, Nikhil; Lang, Roberto M; Liarski, Vladimir M; Jeevanandam, Valluvan; Hofmann Bowman, Marion A

    2017-01-01

    A 55-year-old man with a history of erosive, seropositive rheumatoid arthritis (RA), and interstitial lung disease presented with shortness of breath. Echocardiography showed new-onset severe left ventricular (LV) dysfunction with an ejection fraction (EF) of 15% and moderately increased mean aortic valve gradient of 20 mmHg in a trileaflet aortic valve with severe sclero-calcific degeneration. Coronary angiography revealed no significant obstructive coronary disease. Invasive hemodynamic studies and dobutamine stress echocardiography were consistent with moderate aortic stenosis. Guideline directed medical therapy for heart failure with reduced EF was initiated; however, diuretics and neurohormonal blockade (beta-blocker and angiotensin receptor blocker) provided minimal improvement, and the patient remained functionally limited. Of interest, echocardiography performed 1 year prior to his presentation showed normal LV EF and mild aortic leaflet calcification with moderate stenosis, suggesting a rapid progressing of calcific aortic valve disease. Subsequently, the patient underwent surgical aortic valve replacement and demonstrated excellent postsurgical recovery of LV EF (55%). Calcific aortic valve disease is commonly associated with aging, bicuspid aortic valve, and chronic kidney disease. Pathophysiological mechanism for valvular calcification is incompletely understood but include osteogenic transformation of valvular interstitial cells mediated by local and systemic inflammatory processes. Several rheumatologic diseases including RA are associated with premature atherosclerosis and arterial calcification, and we speculated a similar role of RA accelerating calcific aortic valve disease. We present a case of accelerated aortic valve calcification with (only) moderate stenosis, complicated by a rapid decline in LV systolic performance. Guidelines for AVR in moderate stenosis without concomitant cardiac surgery are not well established, although it should be

  6. Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?

    PubMed

    Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-11-01

    Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.

  7. Remote actuated valve implant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  8. Analysis of the STS-126 Flow Control Valve Structural-Acoustic Coupling Failure

    NASA Technical Reports Server (NTRS)

    Jones, Trevor M.; Larko, Jeffrey M.; McNelis, Mark E.

    2010-01-01

    During the Space Transportation System mission STS-126, one of the main engine's flow control valves incurred an unexpected failure. A section of the valve broke off during liftoff. It is theorized that an acoustic mode of the flowing fuel, coupled with a structural mode of the valve, causing a high cycle fatigue failure. This report documents the analysis efforts conducted in an attempt to verify this theory. Hand calculations, computational fluid dynamics, and finite element methods are all implemented and analyses are performed using steady-state methods in addition to transient analysis methods. The conclusion of the analyses is that there is a critical acoustic mode that aligns with a structural mode of the valve

  9. Valve for fluid control

    DOEpatents

    Oborny, Michael C.; Paul, Phillip H.; Hencken, Kenneth R.; Frye-Mason, Gregory C.; Manginell, Ronald P.

    2001-01-01

    A valve for controlling fluid flows. This valve, which includes both an actuation device and a valve body provides: the ability to incorporate both the actuation device and valve into a unitary structure that can be placed onto a microchip, the ability to generate higher actuation pressures and thus control higher fluid pressures than conventional microvalves, and a device that draws only microwatts of power. An electrokinetic pump that converts electric potential to hydraulic force is used to operate, or actuate, the valve.

  10. 4D optical coherence tomography of aortic valve dynamics in a murine mouse model ex vivo

    NASA Astrophysics Data System (ADS)

    Schnabel, Christian; Jannasch, Anett; Faak, Saskia; Waldow, Thomas; Koch, Edmund

    2015-07-01

    The heart and its mechanical components, especially the heart valves and leaflets, are under enormous strain during lifetime. Like all highly stressed materials, also these biological components undergo fatigue and signs of wear, which impinge upon cardiac output and in the end on health and living comfort of affected patients. Thereby pathophysiological changes of the aortic valve leading to calcific aortic valve stenosis (AVS) as most frequent heart valve disease in humans are of particular interest. The knowledge about changes of the dynamic behavior during the course of this disease and the possibility of early stage diagnosis could lead to the development of new treatment strategies and drug-based options of prevention or therapy. ApoE-/- mice as established model of AVS versus wildtype mice were introduced in an ex vivo artificially stimulated heart model. 4D optical coherence tomography (OCT) in combination with high-speed video microscopy were applied to characterize dynamic behavior of the murine aortic valve and to characterize dynamic properties during artificial stimulation. OCT and high-speed video microscopy with high spatial and temporal resolution represent promising tools for the investigation of dynamic behavior and their changes in calcific aortic stenosis disease models in mice.

  11. Diagnostic value of color flow mapping and Doppler echocardiography in the quantification of mitral regurgitation in patients with mitral valve prolapse or rheumatic heart disease.

    PubMed

    Pinheiro, Aurélio Carvalho; Mancuso, Frederico José Neves; Hemerly, Daniela Fernanda Alli; Kiyose, Alberto Takeshi; Campos, Orlando; de Andrade, José Lázaro; de Paola, Angelo Amato Vicenzo; de Camargo Carvalho, Antonio Carlos; Moises, Valdir Ambrosio

    2007-10-01

    The objective was to analyze the diagnostic value of the echocardiographic methods used for quantification of mitral regurgitation (MR) in patients with mitral valve prolapse (MVP) or rheumatic heart disease (RHD). The study included 50 patients with MR (mean age of 46.1 years; 35 women), 27 (54%) with RHD and 23 (46%) with MVP. Quantification of the mitral valve regurgitation was obtained by regurgitant orifice area (ROA) and regurgitant volume (RV) by the flow convergence region (FCR) and two-dimensional Doppler echocardiographic methods, regurgitant fraction, jet area (JA), jet area/left atrial area ratio (JA/LAA), and vena contracta (VC). Patients were clinically followed to identify cardiovascular events. Data were analyzed by Pearson, kappa, and receiver operator characteristic curve tests; significance was defined as a P value less than .05. The correlation between the two methods for ROA and RV were r = 0.79 and r = 0.80, respectively, and between these parameters and regurgitant fraction, VC, JA, and JA/LAA varied from r = 0.54 to r = 0.94 (P lt; .05); the agreement varied from kappa = 0.19 to kappa = 0.83. The highest accuracy to identify patients with clinically significant MR (events at follow-up) was 96% for ROA by FCR, 94% for VC, 86% for RV by FCR, and 86% for JA. No method showed a significant difference between MVP and RHD. The methods analyzed had significant correlation and good agreement. ROA by FCR and VC had the best performance to identify severe MR; no significant difference between MVP and RHD was observed.

  12. Solid handling valve

    DOEpatents

    Williams, William R.

    1979-01-01

    The present invention is directed to a solids handling valve for use in combination with lock hoppers utilized for conveying pulverized coal to a coal gasifier. The valve comprises a fluid-actuated flow control piston disposed within a housing and provided with a tapered primary seal having a recessed seat on the housing and a radially expandable fluid-actuated secondary seal. The valve seals are highly resistive to corrosion, erosion and abrasion by the solids, liquids, and gases associated with the gasification process so as to minimize valve failure.

  13. VALVE

    DOEpatents

    Arkelyan, A.M.; Rickard, C.L.

    1962-04-17

    A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)

  14. Effects of bileaflet mechanical heart valve orientation on coronary flow

    NASA Astrophysics Data System (ADS)

    Haya, Laura; Tavoularis, Stavros

    2015-11-01

    The aortic sinus is approximately tri-radially symmetric, but bileaflet mechanical heart valves (BMHVs), which are commonly used to replace diseased aortic valves, are bilaterally symmetric. This mismatch in symmetry suggests that the orientation in which a BMHV is implanted within the aortic sinus affects the flow characteristics downstream of it. This study examines the effect of BMHV orientation on the flow in the coronary arteries, which originate in the aortic sinus and supply the heart tissue with blood. Planar particle image velocimetry measurements were made past a BMHV mounted at the inlet of an anatomical aorta model under physiological flow conditions. The complex interactions between the valve jets, the sinus vortex and the flow in the right coronary artery were elucidated for three valve orientations. The coronary flow rate was directly affected by the size, orientation, and time evolution of the vortex in the sinus, all of which were sensitive to the valve's orientation. The total flow through the artery was highest when the valve was oriented with its axis of symmetry intersecting the artery's opening. The findings of this research may assist surgeons in choosing the best orientation for BMHV implantation. The bileaflet valve was donated by St. Jude Medical. Financial support was provided by the Natural Sciences and Engineering Research Council of Canada.

  15. Liquid rocket valve components

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A monograph on valves for use with liquid rocket propellant engines is presented. The configurations of the various types of valves are described and illustrated. Design criteria and recommended practices for the various valves are explained. Tables of data are included to show the chief features of valve components in use on operational vehicles.

  16. Long-Term Health Benefit of Transcatheter Aortic Valve Replacement in Patients With Chronic Lung Disease.

    PubMed

    Crestanello, Juan A; Popma, Jeffrey J; Adams, David H; Deeb, G Michael; Mumtaz, Mubashir; George, Barry; Huang, Jian; Reardon, Michael J

    2017-11-27

    This study sought to characterize the long-term effect of chronic lung disease (CLD) on mortality, clinical outcomes, quality of life, and health benefits after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis. The long-term effect of CLD after TAVR is unknown. Prevalence and severity of CLD was determined at baseline in high- and extreme-risk patients with aortic stenosis from the CoreValve US Pivotal Trial. Clinical outcomes and health status were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OS). A favorable health benefit was defined as alive with a KCCQ-OS ≥60 and stability (<10-point decrease) or improvement in the KCCQ-OS from baseline. CLD was present in 55% (20% mild, 13% moderate, 22% severe) of the 1,030 patients studied. All-cause mortality was higher in patients with moderate and severe CLD at 1 year (19.6% mild, 28.1% moderate, 26.9% severe CLD vs. 19.2% non-CLD; p = 0.030) and 3 years (44.8% mild, 53.0% moderate, 51.9% severe vs. 37.7% non-CLD; p < 0.001). New York Heart Association functional class improved in more than 80% of patients with CLD at 1 and 3 years. All patients had a nearly 20-point improvement in KCCQ-OS at 1 and 3 years. However, only 43.3% of patients with CLD had a favorable health benefit at 1 year and 22.5% at 3 years. Moderate and severe CLD increases 1- and 3-year mortality after TAVR. Although functional status and quality of life were improved in CLD at 1 and 3 years after TAVR, a favorable health benefit was only achieved in selected patients. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Clinical significance of incomplete tricuspid valve closure seen on two-dimensional echocardiography.

    PubMed

    Gibson, T C; Foale, R A; Guyer, D E; Weyman, A E

    1984-11-01

    Incomplete closure of the tricuspid valve without apparent cusp disease was noted on two-dimensional echocardiography in 31 patients. This abnormality was defined as a failure of the tricuspid valve leaflet tips to reach the plane of the tricuspid valve anulus by at least 1 cm in the standard apical four chamber view at the point of maximal systolic closure. This resulted in a final systolic leaflet position deeper within the right ventricular cavity than is normally seen. The finding was present in the following diagnostic subgroups: Group A, pulmonary hypertension (11 patients); Group B, rheumatic heart disease (4 patients); Group C, dilated cardiomyopathy (9 patients) and Group D, previous myocardial infarction (7 patients). Right atrial, right ventricular and tricuspid anulus measurements were made and compared with those from a group of 67 normal subjects. The results were as follows: right atrial endsystolic area = 27.2 +/- 8.6 cm2 (normal = 13.4 +/- 2.0); right ventricular end-systolic area = 25.6 +/- 8.7 cm2 (normal = 10.9 +/- 2.9); right ventricular end-diastolic area = 31.5 +/- 9.1 cm2 (normal = 20.1 +/- 4.9) and tricuspid valve anular end-systolic dimension = 4.0 +/- 0.6 cm (normal = 2.2 +/- 0.3). The differences from the normal data were all statistically significant (p less than 0.001). Incomplete closure of the tricuspid valve, although a nonspecific diagnostic finding, is primarily associated with right-sided chamber enlargement. Tricuspid regurgitation may be present. The mechanism could be related to geometric changes in valve apparatus dynamics secondary to right-sided cardiac enlargement and tricuspid valve anular dilation.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Valve assembly for internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wakeman, R.J.; Shea, S.F.

    1989-09-05

    This patent describes an improvement in a valve assembly for an internal combustion engine of the type including a valve having a valve stem, a valve guideway for mounting this valve for reciprocal strokes between opened and seated position, and spring means for biasing the valve into the seated position. The improvement comprising a valve spool of greater cross-sectional diameter as compared to the valve stem, and a valve spool guideway within which the valve spool is movable during the strokes of the valve, an upper surface of the valve spool and a portion of the spool guideway collectively establishingmore » a damper chamber which varies in volume during the valve strokes. a feed passage for introducing oil into the damper chamber, and a bleed passage for discharging oil from the damper chamber. The bleed passages each laterally opening into the valve spool guideway.« less

  19. Transcatheter Aortic Valve Implantation: Experience with the CoreValve Device.

    PubMed

    Asgar, Anita W; Bonan, Raoul

    2012-01-01

    The field of transcatheter aortic valve implantation has been rapidly evolving. The Medtronic CoreValve first emerged on the landscape in 2004 with initial first human studies, and it is currently being studied in the Pivotal US trial. This article details the current experience with the self-expanding aortic valve with a focus on clinical results and ongoing challenges. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Multiple-port valve

    DOEpatents

    Doody, Thomas J.

    1978-08-22

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable wih one or more of a plurality of secondary conduits fitted into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits.

  1. Fixation and mounting of porcine aortic valves for use in mock circuits.

    PubMed

    Schlöglhofer, Thomas; Aigner, Philipp; Stoiber, Martin; Schima, Heinrich

    2013-10-01

    Investigations of the circulatory system in vitro use mock circuits that require valves to mimic the cardiac situation. Whereas mechanical valves increase water hammer effects due to inherent stiffness and do not allow the use of pressure lines or catheters, bioprosthetic valves are expensive and of limited durability in test fluids. Therefore, we developed a cheap, fast, alternative method to mount valves obtained from the slaughterhouse in mock circuits. Porcine aortic roots were obtained from the abattoir and used either in native condition or after fixation. Fixation was performed at a constant retrograde pressure to ensure closed valve position. Fixation time was 4 h in a 0.5%-glutaraldehyde phosphate buffer. The fixed valves were molded into a modular mock circulation connector using a fast curing silicone. Valve functionality was evaluated in a pulsatile setting (cardiac output = 4.7 l/min, heart rate = 80 beats/min) and compared before and after fixation. Leaflet motion was recorded with a high-speed camera and valve insufficiency was quantified by leakage flow under steady pressure application (80 mmHg). Under physiological conditions the aortic valves showed almost equal leaflet motion in native and fixed conditions. However, the leaflets of the native valves showed lower stiffness and more fluttering during systole than the fixed specimens. Under retrograde pressure, fresh and fixed valves showed small leakage flows of <30 ml/min. The new mounting and fixation procedure is a fast method to fabricate low cost biologic valves for the use in mock circuits.

  2. Sliding-gate valve

    DOEpatents

    Usnick, George B.; Ward, Gene T.; Blair, Henry O.; Roberts, James W.; Warner, Terry N.

    1979-01-01

    This invention is a novel valve of the slidable-gate type. The valve is designed especially for long-term use with highly abrasive slurries. The sealing surfaces of the gate are shielded by the valve seats when the valve is fully open or closed, and the gate-to-seat clearance is swept with an inflowing purge gas while the gate is in transit. A preferred form of the valve includes an annular valve body containing an annular seat assembly defining a flow channel. The seat assembly comprises a first seat ring which is slidably and sealably mounted in the body, and a second seat ring which is tightly fitted in the body. These rings cooperatively define an annular gap which, together with passages in the valve body, forms a guideway extending normal to the channel. A plate-type gate is mounted for reciprocation in the guideway between positions where a portion of the plate closes the channel and where a circular aperture in the gate is in register with the channel. The valve casing includes opposed chambers which extend outwardly from the body along the axis of the guideway to accommodate the end portions of the gate. The chambers are sealed from atmosphere; when the gate is in transit, purge gas is admitted to the chambers and flows inwardly through the gate-to-seat-ring, clearance, minimizing buildup of process solids therein. A shaft reciprocated by an external actuator extends into one of the sealed chambers through a shaft seal and is coupled to an end of the gate. Means are provided for adjusting the clearance between the first seat ring and the gate while the valve is in service.

  3. Vortex dynamics in Patient-Specific Stenotic Tricuspid and Bicuspid Aortic Valves pre- and post- Trans-catheter Aortic Valve Replacement

    NASA Astrophysics Data System (ADS)

    Hatoum, Hoda; Dasi, Lakshmi Prasad

    2017-11-01

    Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.

  4. Solenoid Valve With Self-Compensation

    NASA Technical Reports Server (NTRS)

    Woeller, Fritz H.; Matsumoto, Yutaka

    1987-01-01

    New solenoid-operated miniature shutoff valve provides self-compensation of differential pressure forces that cause jamming or insufficient valve closure as in single-seal valves. Dual-seal valve is bidirectional. Valve simultaneously seals both inlet and outlet tubes by pressing single disk of silicone rubber against ends of both.

  5. Use of signal analysis of heart sounds and murmurs to assess severity of mitral valve regurgitation attributable to myxomatous mitral valve disease in dogs.

    PubMed

    Ljungvall, Ingrid; Ahlstrom, Christer; Höglund, Katja; Hult, Peter; Kvart, Clarence; Borgarelli, Michele; Ask, Per; Häggström, Jens

    2009-05-01

    To investigate use of signal analysis of heart sounds and murmurs in assessing severity of mitral valve regurgitation (mitral regurgitation [MR]) in dogs with myxomatous mitral valve disease (MMVD). 77 client-owned dogs. Cardiac sounds were recorded from dogs evaluated by use of auscultatory and echocardiographic classification systems. Signal analysis techniques were developed to extract 7 sound variables (first frequency peak, murmur energy ratio, murmur duration > 200 Hz, sample entropy and first minimum of the auto mutual information function of the murmurs, and energy ratios of the first heart sound [S1] and second heart sound [S2]). Significant associations were detected between severity of MR and all sound variables, except the energy ratio of S1. An increase in severity of MR resulted in greater contribution of higher frequencies, increased signal irregularity, and decreased energy ratio of S2. The optimal combination of variables for distinguishing dogs with high-intensity murmurs from other dogs was energy ratio of S2 and murmur duration > 200 Hz (sensitivity, 79%; specificity, 71%) by use of the auscultatory classification. By use of the echocardiographic classification, corresponding variables were auto mutual information, first frequency peak, and energy ratio of S2 (sensitivity, 88%; specificity, 82%). Most of the investigated sound variables were significantly associated with severity of MR, which indicated a powerful diagnostic potential for monitoring MMVD. Signal analysis techniques could be valuable for clinicians when performing risk assessment or determining whether special care and more extensive examinations are required.

  6. Prediction and Reduction of Noise in Pneumatic Bleed Valves

    NASA Astrophysics Data System (ADS)

    Taghavi Nezhad, Shervin

    This study investigates numerically the fluid mechanics and acoustics of pneumatic bleed valves used in turbofan engines. The goal is to characterized the fundamental processes of noise generation and devise strategies for noise reduction. Three different methods are employed for both analysis and redesign of the bleed valve to reduce noise. The bleed valve noise problem is carefully divided into multiple smaller problems. For large separations and tonal noises, the unsteady Reynolds-Averaged Navier-Stokes (URANS) method is utilized. This method is also applied in the re-designing of the bleed valve geometry. For the bleed valve muffler, which is comprised of perforated plates and a honeycomb, a Reynolds-Averaged Navier-Stokes (RANS) method combined with a simplified acoustic analogy is used. The original muffler design is modified to improve noise attenuation. Finally, for sound scattering through perforated plates, a fully implicit linearized Euler solver is developed. The problem of sound interaction with perforated plates is studied from two perspectives. In the first study the effect of high--speed mean flow is considered and it is shown that at Strouhal numbers of around 0.2-0.25 there is an increase in transmitted incident sound. In the second part, the interaction of holes in two--dimensional perforated plates is investigated using three different configurations. The study demonstrates that the hole interaction has a significant impact on sound attenuation, especially at high frequencies.

  7. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    DOEpatents

    Lyon, R.H.; Chai, J.; Lang, J.H.; Hagman, W.H.; Umans, S.D.; Saarela, O.J.

    1997-01-14

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.

  8. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    DOEpatents

    Lyon, Richard H.; Chai, Jangbom; Lang, Jeffrey H.; Hagman, Wayne H.; Umans, Stephen D.; Saarela, Olli J.

    1997-01-01

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit.

  9. Ross operation using a bovine bioprosthetic valve with autologous pericardial conduit in the pulmonary position.

    PubMed Central

    Urrea, M S; Herrera, V; Rey, A; Vargas, J

    1993-01-01

    Between 1 February 1992 and 1 March 1993, we performed Ross's aortic replacement in 7 men and 4 women with rheumatic heart disease. The patients' ages ranged from 22 to 60 years (mean, 41 years). All 11 patients had aortic valve disease; 2 also had mitral valve disease. In all patients, the right ventricular outflow tract was reconstructed using an autologous pericardial conduit containing a bovine cardiac valve bioprosthesis manufactured at our institution. The 2 patients who had mitral valve disease underwent a concomitant mitral valvuloplasty. In 1 patient, minimal aortic regurgitation was documented by means of transesophageal echocardiography immediately after the cessation of cardiopulmonary bypass, but no hemodynamic compromise was noted. In another patient, mediastinal exploration was required for bleeding, 3.5 hours postoperatively. The follow-up period ranged from 6 to 16 months (mean, 11.3 months). Results were assessed by means of clinical and transesophageal echocardiographic studies. No infection or technical failure was encountered. No patient died. All patients remain asymptomatic, and follow-up echocardiography has revealed no transaortic or transpulmonary gradient. The Ross operation was chosen for this group of patients because it avoids the use of mechanical valves and subsequent anticoagulant therapy. Most of our patients have a low income and a history of noncompliance with the strict postoperative drug regimen. Although the short-term results have been excellent with the Ross operation and our combination bioprosthesis, long-term evaluation is needed. PMID:8298323

  10. Effect of comprehensive cardiac rehabilitation after heart valve surgery (CopenHeartVR): study protocol for a randomised clinical trial

    PubMed Central

    2013-01-01

    Background Heart valve diseases are common with an estimated prevalence of 2.5% in the Western world. The number is rising due to an ageing population. Once symptomatic, heart valve diseases are potentially lethal, and heavily influence daily living and quality of life. Surgical treatment, either valve replacement or repair, remains the treatment of choice. However, post surgery, the transition to daily living may become a physical, mental and social challenge. We hypothesise that a comprehensive cardiac rehabilitation programme can improve physical capacity and self-assessed mental health and reduce hospitalisation and healthcare costs after heart valve surgery. Methods A randomised clinical trial, CopenHeartVR, aims to investigate whether cardiac rehabilitation in addition to usual care is superior to treatment as usual after heart valve surgery. The trial will randomly allocate 210 patients, 1:1 intervention to control group, using central randomisation, and blinded outcome assessment and statistical analyses. The intervention consists of 12 weeks of physical exercise, and a psycho-educational intervention comprising five consultations. Primary outcome is peak oxygen uptake (VO2 peak) measured by cardiopulmonary exercise testing with ventilatory gas analysis. Secondary outcome is self-assessed mental health measured by the standardised questionnaire Short Form 36. Also, long-term healthcare utilisation and mortality as well as biochemistry, echocardiography and cost-benefit will be assessed. A mixed-method design is used to evaluate qualitative and quantitative findings encompassing a survey-based study before the trial and a qualitative pre- and post-intervention study. Discussion The study is approved by the local regional Research Ethics Committee (H-1-2011-157), and the Danish Data Protection Agency (j.nr. 2007-58-0015). Trial registration ClinicalTrials.gov (http://NCT01558765). PMID:23782510

  11. Study of multiple cycles valves

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1973-01-01

    A discussion is presented regarding valves which can be cycled repeatedly and are available from industry for application in the inlet system for the Pioneer Venus Probe mass spectrometer. Both solenoid type and latching type valves are considered. The study is divided into two principal areas: (1) preparation of a valve specification reflecting the requirements of the inlet system cyclic valves for the Pioneer Venus Probe mass spectrometer and the submittal of this specification to potential valve suppliers for their response and proposal; (2) preparation of a design layout of an optimum cyclic valve meeting all of the valve specification requirements.

  12. In vitro evaluation of valve hemodynamics in the pediatric pulmonary outflow tract

    NASA Astrophysics Data System (ADS)

    Schiavone, Nicole; Elkins, Chris; McElhinney, Doff; Eaton, John; Marsden, Alison

    2016-11-01

    Tetraology of Fallot (ToF) is a congenital heart disease that affects 1 in every 2500 newborns each year and requires surgical repair of the right ventricular outflow tract (RVOT) and subsequent placement of an artificial pulmonary valve. While a wide variety of artificial valves are available, essentially all of them become subject to degradation and dysfunction during the patient's lifetime, which leads to additional interventions. However, there is little understanding about the mechanical function of replacement pulmonary valves and no quantitative placement guidelines to ensure maximum failure-free lifetime. This work aims to experimentally assess the biomechanics of pulmonary valves in realistic RVOT geometries using magnetic resonance velocimetry (MRV), which can measure 3D, three-component phase-averaged velocity fields. The RVOT geometries are constructed using 3D printing, allowing for variation in crucial geometric parameters such as the radius of curvature of the main pulmonary artery (MPA) and the dilation of the artery downstream of the valve. A St. Jude Medical Epic valve is secured inside the RVOT geometry and can be interchanged, allowing for variation of the ratio between valve diameter and MPA diameter. This work will discuss the use of MRV to capture the flow structure in the RVOT and evaluate pulmonary valve performance under different conditions.

  13. Magnetic Check Valve

    NASA Technical Reports Server (NTRS)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  14. Inexpensive, rapid fabrication of polymer-film microfluidic autoregulatory valve for disposable microfluidics.

    PubMed

    Zhang, Xinjie; Zhu, Zhixian; Ni, Zhonghua; Xiang, Nan; Yi, Hong

    2017-06-01

    This work presents the fabrication of a microfluidic autoregulatory valve which is composed of several layers of thin polymer films (i.e., polyvinyl chloride (PVC), polyethylene terephthalate (PET) double-sided tape, and polydimethylsiloxane (PDMS)). Briefly, pulsed UV laser is employed to cut the microstructures of through grooves or holes in the thermoplastic polymer films, and then the polymer-film valves are precisely assembled through laminating the PDMS membranes to the thermoplastic polymer films through the roll-lamination method. The effective bonding between the PVC film and the PDMS membrane is realized using the planar seal method, and the valve is sandwiched and compressed by a home-made housing to achieve the good seal effect. Then, the flow performances of the prototype valve are examined, and constant flow autoregulation is realized under the static or dynamic test pressures. The long-term response of the valve is also studied and minimum flow-rate decrements are found over a long actuation time. The fabrication method proposed in this work is successful for the low-cost and fast prototyping of the polymer-film valve. We believe our method will also be broadly applicable for fabrication of other low-cost and disposable polymer-film microfluidic devices.

  15. Morphometric analysis of tricuspid valve: An Indian perspective

    PubMed Central

    Kalyani, R.; Thej, M. J.; Prabhakar, K.; Venkatesh, T. K.; Thomas, A. K.; Kiran, J.

    2012-01-01

    Background: The morphometry of tricuspid valve complex is of clinical importance for cardiovascular surgeons and there is scarcity of such data in Indian literature. The study was conducted to record normal tricuspid valve measurements which would serve as baseline data for the Indian population. Material and Methods: The study was carried out on 100 formalin fixed hearts without any pathology from patients who had died of non-vascular causes and whose age ranged from 8 to 85 yrs. The hearts were grouped into three cohorts corresponding to age, 54 hearts aged between 8 to 40 yrs, 42 hearts aged between 41 to 64 yrs and 4 hearts aged 65 yrs and above. Dissection was performed according to standard autopsy techniques. The measurements were recorded using a flexible millimeter ruler and surgical suture material. The dimensions measured were the attachment lengths of anterior, posterior and septal leaflets. The circumference of the valve along with the frontal and sagittal dimensions was measured. Area of the valve expressed as a triangle and as an ellipse was calculated. Results: The measurements obtained were assessed using SPSS software. Statistically significant increase in tricuspid valve measurements were observed with advancing age both in men and women. In younger hearts the tricuspid valve resembled a triangle and with advancing age the tricuspid valve became more elliptical in shape. Conclusion: We hope this study will serve as baseline data for the tricuspid valve measurements in the Indian population and it will be of clinical use for patients with various tricuspid valve abnormalities. PMID:23225976

  16. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    PubMed

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  17. Azygos vein aneurysm resection concomitant with heart valve repair via right thoracotomy.

    PubMed

    Suzuki, Yota; Kaji, Masahiro; Hirose, Shigemichi; Ohtsubo, Satoshi

    2016-12-01

    Azygos vein aneurysm is very rare and is usually found incidentally because of its clinical silence. We report a case of recurrent pleural effusion caused by an azygos vein aneurysm in a patient with moderate mitral valve regurgitation (MR) and tricuspid valve regurgitation (TR). Since valve disease is considered a significant precipitating factor for both dyspnoea and pleural effusion, we decided to study the aetiologies of these conditions concomitantly. Azygos vein aneurysm resection in combination with tricuspid and mitral valve repair using cardiopulmonary bypass was performed successfully through a right anterior thoracotomy. The postoperative course was uneventful, and the patient reported improved exercise capacity. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Fast acting multiple element valve

    DOEpatents

    Yang, Jefferson Y. S.; Wada, James M.

    1991-01-01

    A plurality of slide valve elements having plural axial-spaced annular parts and an internal slide are inserted into a bulkhead in a fluid conduit from a downstream side of the bulkhead, locked in place by a bayonet coupling and set screw, and project through the bulkhead into the upstream conduit. Pneumatic lines connecting the slide valve element actuator to pilot valves are brought out the throat of the valve element to the downstream side. Pilot valves are radially spaced around the exterior of the valve to permit the pneumatic lines to be made identical, thereby to minimize adverse timing tolerances in operation due to pressure variations. Ring manifolds surround the valve adjacent respective pilot valve arrangements to further reduce adverse timing tolerances due to pressure variations, the manifolds being directly connected to the respective pilot valves. Position sensors are provided the valve element slides to signal the precise time at which a slide reaches or passes through a particular point in its stroke to initiate a calibrated timing function.

  19. A planning system for transapical aortic valve implantation

    NASA Astrophysics Data System (ADS)

    Gessat, Michael; Merk, Denis R.; Falk, Volkmar; Walther, Thomas; Jacobs, Stefan; Nöttling, Alois; Burgert, Oliver

    2009-02-01

    Stenosis of the aortic valve is a common cardiac disease. It is usually corrected surgically by replacing the valve with a mechanical or biological prosthesis. Transapical aortic valve implantation is an experimental minimally invasive surgical technique that is applied to patients with high operative risk to avoid pulmonary arrest. A stented biological prosthesis is mounted on a catheter. Through small incisions in the fifth intercostal space and the apex of the heart, the catheter is positioned under flouroscopy in the aortic root. The stent is expanded and unfolds the valve which is thereby implanted into the aortic root. Exact targeting is crucial, since major complications can arise from a misplaced valve. Planning software for the perioperative use is presented that allows for selection of the best fitting implant and calculation of the safe target area for that implant. The software uses contrast enhanced perioperative DynaCT images acquired under rapid pacing. In a semiautomatic process, a surface segmentation of the aortic root is created. User selected anatomical landmarks are used to calculate the geometric constraints for the size and position of the implant. The software is integrated into a PACS network based on DICOM communication to query and receive the images and implants templates from a PACS server. The planning results can be exported to the same server and from there can be rertieved by an intraoperative catheter guidance device.

  20. Conical Seat Shut-Off Valve

    NASA Technical Reports Server (NTRS)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  1. Histopathological assessment of calcification and inflammation of calcific aortic valves from patients with and without diabetes mellitus.

    PubMed

    Mosch, Josephin; Gleissner, Christian A; Body, Simon; Aikawa, Elena

    2017-03-01

    Calcific aortic valve disease (CAVD) is the most common valvular heart disease and likely evolves from inflammatory pre-conditions in the valve. Type II diabetes mellitus (DMII) has been associated with pathogenesis of CAVD, however, the mechanism initiating CAVD in DMII is not well understood and the human valve pathology in DMII has not been described. We therefore performed quantitative histological analyses of aortic valves of CAVD patients with and without DMII. CAVD human aortic valves (n=45) obtained after surgical valve replacement were examined macroscopically with gross measurements of calcified areas. Inflammation and calcification were assessed by immunohistochemistry and immunofluorescence staining. Calcification was increased in diabetic patients according to gross measurements (p<0.01) and alizarin red staining (p=0.05). Early calcification markers, including Runx2 (p=0.02) and alkaline phosphatase (ALP, p=0.03) were significantly elevated in diabetic patients. Furthermore, in diabetic patients we found significantly increased expression of annexin II (p=0.04) and annexin V (p=0.04), both of which are thought to play a role in microcalcification formation via apoptosis or extracellular vesicle release. Macrophage numbers were comparable in both groups (p=0.41), while the expression of the pro-inflammatory protein S100A9 (p<0.01) was significantly decreased in diabetic individuals. Evaluation of lymphocytes revealed similar CD8 (p=0.45) and CD4 (p=0.92) T cell counts in diabetic and non-diabetic aortic valves. Aortic valves from diabetic patients show more calcification, while inflammation is similar in both patient populations. Considering the generally accepted theory of an inflammation-dependent mechanism of calcification, these data suggest that in patients with CAVD requiring valve replacement, diabetic patients could be molecularly in a more advanced disease stage with a higher grade of mineralization than non-diabetic patients.

  2. Aortic Valve Disease and Vascular Mechanics: Two-Dimensional Speckle Tracking Echocardiographic Analysis.

    PubMed

    Leite, Luís; Teixeira, Rogério; Oliveira-Santos, Manuel; Barbosa, António; Martins, Rui; Castro, Graça; Gonçalves, Lino; Pego, Mariano

    2016-08-01

    Degenerative aortic valve disease (AVD) is a complex disorder that goes beyond valve itself, also undermining aortic wall. We aimed to assess the ascending aortic mechanics with two-dimensional speckle tracking echocardiography (2DSTE) in patients with aortic regurgitation (AR) and hypothesized a relationship with degree of AR. Aortic mechanics were then compared with those of similarly studied healthy controls and patients with aortic stenosis (AS); finally, we aimed to assess the prognostic significance of vascular mechanics in AVD. Overall, 73 patients with moderate-to-severe AR and 22 healthy subjects were enrolled, alongside a previously examined cohort (N = 45) with moderate-to-severe AS. Global circumferential ascending aortic strain (CAAS) and strain rate (CAASR) served as indices of aortic deformation; corrected CAAS was calculated as CAAS/pulse pressure (PP). Median clinical follow-up was 438 days. In patients with severe (vs. moderate) AR, CAASR (1.53 ± 0.29/sec vs. 1.90 ± 0.62/sec, P < 0.05) and corrected CAAS (0.14 ± 0.06%/mmHg vs. 0.19 ± 0.08%/mmHg, P < 0.05) were significantly lower, whereas CAAS did not differ significantly. Measurers of aortic mechanics (CAAS, corrected CAAS, CAASR) differed significantly (all P < 0.01) in patients with AS and AR and in healthy subjects, with lower values seen in patients with AS. In follow-up, survival rate of AVD patients with baseline CAASR >0.88/sec was significantly higher (log rank, 97.4% vs. 73.0%; P = 0.03). Quantitative measures of aortic mechanics were lower for AS patients, suggesting a more significant derangement of aortic elastic properties. In the context of AVD, vascular mechanics assessment proved useful in gauging clinical prognosis. © 2016, Wiley Periodicals, Inc.

  3. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, J.A.

    1980-05-16

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  4. Fast-acting valve and uses thereof

    DOEpatents

    Meyer, James A.

    1982-01-01

    A very fast acting valve capable of producing a very well-defined plug of gas suitable for filling a theta pinch vacuum vessel is given. The valve requires no springs, instead being stopped mainly by a nonlinear force. Thus, the valve is not subject to bouncing; and the ratio of the size of the valve housing to the size of the valve stem is smaller than it would be if springs were needed to stop the valve stem. Furthermore, the valve can be used for thousands of valve firings with no apparent valve damage.

  5. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    PubMed

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  6. Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial

    PubMed Central

    McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.

    2014-01-01

    Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID

  7. Heart valve surgery - series (image)

    MedlinePlus

    ... heart valves are either natural (biologic) or artificial (mechanical). Natural valves are from human donors (cadavers), modified ... artificial valves will require anticoagulation. The advantage of mechanical valves is that they last longer-thus, the ...

  8. Cylinder To Cylinder Balancing Using Intake Valve Actuation

    DOEpatents

    Duffy, Kevin P.; Kieser, Andrew J.; Kilkenny, Jonathan P.

    2005-01-18

    A method and apparatus for balancing a combustion phasing between a plurality of cylinders located in an engine. The method and apparatus includes a determining a combustion timing in each cylinder, establishing a baseline parameter for a desired combustion timing, and varying actuation of at least one of a plurality of intake valves, each intake valve being in fluid communication with a corresponding cylinder, such that the combustion timing in each cylinder is substantially equal to the desired combustion timing.

  9. Valve Repair or Replacement

    MedlinePlus

    ... called anticoagulants) for the rest of their lives. Biological valves are made from animal tissue (called a ... for valve replacement (called an autograft). Patients with biological valves usually do not need to take blood- ...

  10. Early Outcomes of Sutureless Aortic Valves.

    PubMed

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-06-01

    In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  11. Dynamic performance of high speed solenoid valve with parallel coils

    NASA Astrophysics Data System (ADS)

    Kong, Xiaowu; Li, Shizhen

    2014-07-01

    The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts. The increase of magnetic force usually leads to the decrease of current slew rate, which could increase the delay time of the dynamic response of solenoid valve. Using a high voltage to drive coil can solve this contradiction, but a high driving voltage can also lead to more cost and a decrease of safety and reliability. In this paper, a new scheme of parallel coils is investigated, in which the single coil of solenoid is replaced by parallel coils with same ampere turns. Based on the mathematic model of high speed solenoid valve, the theoretical formula for the delay time of solenoid valve is deduced. Both the theoretical analysis and the dynamic simulation show that the effect of dividing a single coil into N parallel sub-coils is close to that of driving the single coil with N times of the original driving voltage as far as the delay time of solenoid valve is concerned. A specific test bench is designed to measure the dynamic performance of high speed on/off solenoid valve. The experimental results also prove that both the delay time and switching time of the solenoid valves can be decreased greatly by adopting the parallel coil scheme. This research presents a simple and practical method to improve the dynamic performance of high speed on/off solenoid valve.

  12. Biocor No- React stentless aortic valve--short-term results.

    PubMed

    Von Oppell, U O; Stemmet, F; Levetan, B; Heijke, S A; Brink, J

    2001-01-01

    Short-term results of the bioprosthetic Biocor No-React composite porcine stentless aortic valve (Biocor Industria e Pesquisas LTDA, Belo Horizonte, Brazil) implanted in patients in whom anticoagulation was thought to be contraindicated or expected to be non-compliant. Retrospective review of 52 consecutive prospective patients in whom this valve was implanted, between September 1994 and May 1998. Average age was 44 +/- 17 years; 75% of patients were operated on for rheumatic heart disease and combined procedures were done in 40% of cases. Early mortality was 5.8%, and related to pre-operative ejection fraction ( P < 0.03), New York Heart Association (NYHA) class (P < 0.01), and bacterial endocarditis (P < 0.04). On discharge, 84% of survivors were in NYHA class I and 16% in class II. The average postoperative prosthetic valve peak gradient on echocardiography was 19.9 +/- 11 mmHg and was related to pre-operative ejection fraction and smaller valve sizes. Postoperative residual trivial or mild aortic regurgitation was seen in 19 patients (36.6%), resolved on follow-up in 10 cases, and did not correlate with structural deterioration, re-operation, mortality, or widening of the non-coronary sinus. The non-coronary aortic sinus was widened on closure, because of perceived crowding of the adjacent stentless valve commisures, in 52% of cases. This was thought to be related to the use of an oblique as opposed to transverse aortotomy. Patient survival, inclusive of operative deaths, was 88.5%, and event-free survival was 80.0% at 4 years. The short-term results of this stentless aortic valve in a young predominantly third-world population group are acceptable, and appear to be superior to the results for mechanical valves in a similar patient group. We would recommend a transverse aortotomy above the sinotubular ridge to be the more appropriate aortotomy incision when using stentless aortic valves.

  13. Histopathology of valves in infective endocarditis, diagnostic criteria and treatment considerations.

    PubMed

    Brandão, Tatiana J D; Januario-da-Silva, Carolina A; Correia, Marcelo G; Zappa, Monica; Abrantes, Jaime A; Dantas, Angela M R; Golebiovski, Wilma; Barbosa, Giovanna Ianini F; Weksler, Clara; Lamas, Cristiane C

    2017-04-01

    Infective endocarditis (IE) is a severe disease. Pathogen isolation is fundamental so as to treat effectively and reduce morbidity and mortality. Blood and valve culture and histopathology (HP) are routinely employed for this purpose. Valve HP is the gold standard for diagnosis. To determine the sensitivity and specificity of clinical criteria for IE (the modified Duke and the St Thomas' minor modifications, STH) of blood and valve culture compared to valve HP, and to evaluate antibiotic treatment duration. Prospective case series of patients, from 2006 to 2014 with surgically treated IE. Statistical analysis was done by the R software. There were 136 clinically definite episodes of IE in 133 patients. Mean age ± SD was 43 ± 15.6 years and IE was left sided in 81.6 %. HP was definite in 96 valves examined, which were used as gold standard. Sensitivity of blood culture was 61 % (CI 0.51, 0.71) and of valve culture 15 % (CI 0.07, 0.26). The modified Duke criteria were 65 % (CI 0.55, 0.75) sensitive and 33 % specific, while the STH's sensitivity was 72 % (CI 0.61, 0.80) with similar specificity. In multivariate analysis and logistic regression, the only variable with statistical significance was duration of antibiotic therapy postoperatively. Valve HP had high sensitivity and valve culture low sensitivity in the diagnosis of IE. The STH's criteria were more sensitive than the modified Duke criteria. Valve HP should guide duration of postoperative antibiotic treatment.

  14. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyon, R.H.; Chai, J.; Lang, J.H.

    1997-01-14

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signalmore » and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.« less

  15. Two-dimensional echocardiographic estimates of left atrial function in healthy dogs and dogs with myxomatous mitral valve disease.

    PubMed

    Dickson, David; Caivano, Domenico; Matos, Jose Novo; Summerfield, Nuala; Rishniw, Mark

    2017-12-01

    To provide reference intervals for 2-dimensional linear and area-based estimates of left atrial (LA) function in healthy dogs and to evaluate the ability of estimates of LA function to differentiate dogs with subclinical myxomatous mitral valve disease (MMVD) and similarly affected dogs with congestive heart failure (CHF). Fifty-two healthy adult dogs, 88 dogs with MMVD of varying severity. Linear and area measurements from 2-dimensional echocardiographs in both right parasternal long and short axis views optimized for the left atrium were used to derive estimates of LA active emptying fraction, passive emptying fraction, expansion index, and total fractional emptying. Differences for each estimate were compared between healthy and MMVD dogs (based on ACVIM classification), and between MMVD dogs with subclinical disease and CHF that had similar LA dimensions. Diagnostic utility at identifying CHF was examined for dogs with subclinical MMVD and CHF. Relationships with bodyweight were assessed. All estimates of LA function decreased with increasing ACVIM stage of mitral valve disease (p<0.05) and showed negative relationships with increasing LA size (all r 2 values < 0.2), except for LA passive emptying fraction, which did not differ or correlate with LA size (p=0.4). However, no index of LA function identified CHF better than measurements of LA size. Total LA fractional emptying and expansion index showed modest negative correlations with bodyweight. Estimates of LA function worsen with worsening MMVD but fail to discriminate dogs with CHF from those with subclinical MMVD any better than simple estimates of LA size. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Intraoperative echocardiographic detection of regurgitant jets after valve replacement

    NASA Technical Reports Server (NTRS)

    Morehead, A. J.; Firstenberg, M. S.; Shiota, T.; Qin, J.; Armstrong, G.; Cosgrove, D. M. 3rd; Thomas, J. D.

    2000-01-01

    BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.

  17. Locking apparatus for gate valves

    DOEpatents

    Fabyan, J.; Williams, C.W.

    A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing further movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.

  18. A 29-year-old Harken disk mitral valve: long-term follow-up by echocardiographic and cineradiographic imaging.

    PubMed

    Hsi, David H; Ryan, Gerald F; Taft, Janice; Arnone, Thomas J

    2003-01-01

    An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patients 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features.

  19. Clinical Trial Design Principles and Endpoint Definitions for Transcatheter Mitral Valve Repair and Replacement: Part 2: Endpoint Definitions: A Consensus Document From the Mitral Valve Academic Research Consortium.

    PubMed

    Stone, Gregg W; Adams, David H; Abraham, William T; Kappetein, Arie Pieter; Généreux, Philippe; Vranckx, Pascal; Mehran, Roxana; Kuck, Karl-Heinz; Leon, Martin B; Piazza, Nicolo; Head, Stuart J; Filippatos, Gerasimos; Vahanian, Alec S

    2015-07-21

    Mitral regurgitation (MR) is one of the most prevalent valve disorders and has numerous etiologies, including primary (organic) MR, due to underlying degenerative/structural mitral valve (MV) pathology, and secondary (functional) MR, which is principally caused by global or regional left ventricular remodeling and/or severe left atrial dilation. Diagnosis and optimal management of MR requires integration of valve disease and heart failure specialists, MV cardiac surgeons, interventional cardiologists with expertise in structural heart disease, and imaging experts. The introduction of transcatheter MV therapies has highlighted the need for a consensus approach to pragmatic clinical trial design and uniform endpoint definitions to evaluate outcomes in patients with MR. The Mitral Valve Academic Research Consortium is a collaboration between leading academic research organizations and physician-scientists specializing in MV disease from the United States and Europe. Three in-person meetings were held in Virginia and New York during which 44 heart failure, valve, and imaging experts, MV surgeons and interventional cardiologists, clinical trial specialists and statisticians, and representatives from the U.S. Food and Drug Administration considered all aspects of MV pathophysiology, prognosis, and therapies, culminating in a 2-part document describing consensus recommendations for clinical trial design (Part 1) and endpoint definitions (Part 2) to guide evaluation of transcatheter and surgical therapies for MR. The adoption of these recommendations will afford robustness and consistency in the comparative effectiveness evaluation of new devices and approaches to treat MR. These principles may be useful for regulatory assessment of new transcatheter MV devices, as well as for monitoring local and regional outcomes to guide quality improvement initiatives. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Long life valve design concepts

    NASA Technical Reports Server (NTRS)

    Jones, J. R.; Hall, A. H., Jr.

    1975-01-01

    Valve concept evaluation, final candidate selection, design, manufacture, and demonstration testing of a pneumatically actuated 10-inch hybrid poppet butterfly shutoff valve are presented. Conclusions and recommendations regarding those valve characteristics and features which would serve to guide in the formulation of future valve procurements are discussed. The pertinent design goals were temperature range of plus 200 to minus 423 F, valve inlet pressure 35 psia, actuation pressure 750 psia, main seal leakage 3 x 0.00001 sccs at 35 psia valve inlet pressure, and a storage and operating life of 10 years. The valve was designed to be compatible with RP-1, propane, LH2, LO2, He, and N2.

  1. Mid-term results of cardiac autotransplantation as method to treat permanent atrial fibrillation and mitral disease.

    PubMed

    Troise, Giovanni; Cirillo, Marco; Brunelli, Federico; Tasca, Giordano; Amaducci, Andrea; Mhagna, Zen; Tomba, Margherita Dalla; Quaini, Eugenio

    2004-06-01

    The results of current surgical options for the treatment of permanent atrial fibrillation (AF) associated with mitral surgery are widely different, particularly in very enlarged left atria. The aim of this study was to assess the mid-term efficacy of cardiac autotransplantation for this goal, through a consistent reduction of left atrium volume and a complete isolation of the pulmonary veins. From April 2000 to September 2002, 30 patients (male/female 5/25) underwent cardiac autotransplantation for the treatment of mitral valve disease and concomitant permanent AF (>1 year). Surgical technique of bicaval heart transplantation was modified maintaining the connection of inferior vena cava in all but three cases. Twenty-eight patients had mitral valve replacement and two had mitral valve repair. Associated procedures were: aortic valve replacement (6 cases), tricuspid valve repair (2 cases), coronary re-vascularization (2 cases) and right atrium volume reduction (4 cases). No hospital death occurred; 1 patient died 3 months post-operatively for pneumonia. At a mean follow-up of 21.1+/-7.7 months (range 6-35), 26 patients (89.7%) were in sinus rhythm and 3 (10.3%) in AF. Santa Cruz Score was 0 in 3 patients, 2 in 2 patients and 4 in the remaining 24 patients (82.7%). Mean left atrial diameter and volume decreased from 65.1+/-16.4 mm (range 50-130 mm) to 49.9+/-8.4 mm (range 37-78) (P < 0.001) and from 118.3+/-68.4 ml (range 60-426) to 69.4+/-34.1 ml (range 31-226) (P = 0.001), respectively, after the operation. Cardiac autotransplantation is a safe and effective option for the treatment of permanent AF in patients with mitral valve disease and severe dilation of left atrium.

  2. Criteria for determining the need for surgical treatment of tricuspid regurgitation during mitral valve replacement

    PubMed Central

    2012-01-01

    Background Tricuspid regurgitation (TR) is common in patients with mitral valve disease; however, there are no straightforward, rapidly determinably criteria available for deciding whether TR repair should be performed during mitral valve replacement. The aim of our retrospective study was to identify a simple and fast criterion for determining whether TR repair should be performed in patients undergoing mitral valve replacement. Methods We reviewed the records of patients who underwent mitral valve replacement with or without (control) TR repair (DeVega or Kay procedure) from January 2005 to December 2008. Preoperative and 2-year postoperative echocardiographic measurements included right ventricular and atrial diameter, interventricular septum size, TR severity, ejection fraction, and pulmonary artery pressure. Results A total of 89 patients were included (control, n = 50; DeVega, n = 27; Kay, n = 12). Demographic and clinical characteristics were similar between groups. Cardiac variables were similar between the DeVega and Kay groups. Right atrium and ventricular diameter and ejection fraction were significantly decreased postoperatively both in the control and operation (DeVega + Kay) group (P < 0.05). Pulmonary artery pressure was significantly decreased postoperatively in-operation groups (P < 0.05). Our findings indicate that surgical intervention for TR should be considered during mitral valve replacement if any of the following preoperative criteria are met: right atrial transverse diameter > 57 mm; right ventricular end-diastolic diameter > 55 mm; pulmonary artery pressure > 58 mmHg. Conclusions Our findings suggest echocardiography may be used as a rapid and simple means of determining which patients require TR repair during mitral valve replacement. PMID:22443513

  3. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    PubMed

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no

  4. Compact valve actuation mechanism

    NASA Technical Reports Server (NTRS)

    Brogdon, James William (Inventor); Gill, David Keith (Inventor)

    2000-01-01

    A valve actuation device. The device may include a free floating valve bridge movably supported within a cavity in the engine housing. The bridge may be provided with a cavity and an orifice arrangement for pumping gases entrained with lubricating fluid toward the piston stems as the bridge reciprocates back and forth. The device may also include a rocker arm that has a U-shaped cross-sectional shape for receiving at least a portion of the valve bridge, valve stem valve spring and spring retainer therein. The rocker arm may be provided with lubrication passages for directing lubrication to the point wherein it is pivotally affixed to the engine housing.

  5. Permanent pacemaker lead induced severe tricuspid regurgitation in patient undergoing multiple valve surgery.

    PubMed

    Lee, Jung Hee; Kim, Tae Ho; Kim, Wook Sung

    2015-04-01

    Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

  6. Improved mitral valve coaptation and reduced mitral valve annular size after percutaneous mitral valve repair (PMVR) using the MitraClip system.

    PubMed

    Patzelt, Johannes; Zhang, Yingying; Magunia, Harry; Ulrich, Miriam; Jorbenadze, Rezo; Droppa, Michal; Zhang, Wenzhong; Lausberg, Henning; Walker, Tobias; Rosenberger, Peter; Seizer, Peter; Gawaz, Meinrad; Langer, Harald F

    2017-08-01

    Improved mitral valve leaflet coaptation with consecutive reduction of mitral regurgitation (MR) is a central goal of percutaneous mitral valve repair (PMVR) with the MitraClip® system. As influences of PMVR on mitral valve geometry have been suggested before, we examined the effect of the procedure on mitral annular size in relation to procedural outcome. Geometry of the mitral valve annulus was evaluated in 183 patients undergoing PMVR using echocardiography before and after the procedure and at follow-up. Mitral valve annular anterior-posterior (ap) diameter decreased from 34.0 ± 4.3 to 31.3 ± 4.9 mm (P < 0.001), and medio-lateral (ml) diameter from 33.2 ± 4.8 to 32.4 ± 4.9 mm (P < 0.001). Accordingly, we observed an increase in MV leaflet coaptation after PMVR. The reduction of mitral valve ap diameter showed a significant inverse correlation with residual MR. Importantly, the reduction of mitral valve ap diameter persisted at follow-up (31.3 ± 4.9 mm post PMVR, 28.4 ± 5.3 mm at follow-up). This study demonstrates mechanical approximation of both mitral valve annulus edges with improved mitral valve annular coaptation by PMVR using the MitraClip® system, which correlates with residual MR in patients with MR. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  7. Valve technology: A compilation

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A technical compilation on the types, applications and modifications to certain valves is presented. Data cover the following: (1) valves that feature automatic response to stimuli (thermal, electrical, fluid pressure, etc.), (2) modified valves changed by redesign of components to increase initial design effectiveness or give the item versatility beyond its basic design capability, and (3) special purpose valves with limited application as presented, but lending themselves to other uses with minor changes.

  8. Aortic valve replacement in elderly patients.

    PubMed

    Glock, Y; Pecoul, R; Cerene, A; Laguerre, J; Puel, P

    1984-01-01

    The results for 62 consecutive patients aged 70 or more given aortic valve replacement (A.V.R.) between 1970 and 1982 are reported. All the patients were in the New York Heart Association (N.Y.H.A.) functional class III (29%) or IV (71%); 54.8% had angina and 30.6% had experienced syncope. Forty patients had aortic stenosis (A.S.), 10 had aortic regurgitation and 12 had mixed aortic valve disease. The operative myocardial infarction rate was 6.4%. Tilting disk valves were used. Eighty percent of the patients were anticoagulated with Warfarin whilst twenty percent received only antiplatelet drugs. All the patients were followed up for a mean period of 26 months; late mortality was 22.6% with 4.8% cardiac deaths. The thromboembolic rate was 1.6% and the disinsertion rate was 3.2%. Cerebral stroke was fatal in 3 cases in anticoagulated patients but the mechanism of the accident was not known. At the termination of the study 93% of surviving patients were in N.Y.H.A. class I or II. No patient was in class IV. The probability of five year survival is 71% for the entire group.

  9. Elastic Valve Using Induced-Charge Electro-Osmosis

    NASA Astrophysics Data System (ADS)

    Sugioka, Hideyuki

    2015-06-01

    Biomimic devices using induced-charge electro-osmosis (ICEO) is interesting since they have the possibility to realize high-performance functions with simple structures and with low-energy consumption. Thus, inspired by a cilium, we propose a two-dimensional artificial elastic valve using hydrodynamic force due to ICEO with a thin elastic beam in a microfluidic channel and numerically examine the valving performance. By an implicit strongly coupled simulation technique between a fluid and an elastic structure based on the boundary-element method, along with the thin-double-layer approximation, we realize stable calculations and find that the elastic valve using ICEO functions effectively at high frequency with low applied voltages in a realistic pressure flow. Further, we also examine passive motion of the valve; i.e., it stops a reverse flow effectively and releases a forward flow in the channel. We believe that our device can be used in a wide range of microfluidic applications, such as mixers, pumps, etc.

  10. Prosthetic valve implantation with preservation of the entire valvular and subvalvular apparatus of the tricuspid valve in congenitally corrected transposition of the great arteries.

    PubMed

    Ergenoglu, Mehmet U; Yerebakan, Halit; Ozveren, Olcay; Koner, Ozge; Kalangos, Afksendiyos; Demirsoy, Ergun

    2011-10-01

    Congenitally corrected transposition of the great arteries, which is characterized by atrioventricular and ventriculoarterial discordance, is a rare congenital heart disease. Most of the cases are diagnosed in childhood, owing to associated cardiac anomalies, such as ventricular septal defect, pulmonary stenosis or pulmonary atresia, and Ebstein-like malformation of the tricuspid valve. We present a patient with congenitally corrected transposition of the great arteries who underwent surgical replacement of the tricuspid valve with a bioprosthesis and reconstruction of the left ventricular outflow tract with bovine conduit.

  11. Influence of aortic valve leaflet calcification on dynamic aortic valve motion assessed by cardiac computed tomography.

    PubMed

    Minami, Keisuke; Yoneyama, Kihei; Izumo, Masaki; Suzuki, Kengo; Ogawa, Yasuyoshi; Chikaraishi, Kousuke; Ogawa, Yukihisa; Kobayashi, Yasuyuki; Furukawa, Toshiyuki; Tanabe, Yasuhiro; Akashi, Yoshihiro J

    Computed tomography is the best noninvasive imaging modality for evaluating valve leaflet calcification. To evaluate the association of aortic valve leaflet calcification with instantaneous valve opening and closing using dynamic multidetector computed tomography (MDCT). We retrospectively evaluated 58 consecutive patients who underwent dynamic MDCT imaging. Aortic valve calcification (AVC) was quantified using the Agatston method. The aortic valve area (AVA) tracking curves were derived by planimetry during the cardiac cycle using all 20 phases (5% reconstruction). da/dt in cm 2 /s was calculated as the rate of change of AVA during opening (positive) or closing (negative). Patients were divided into 3 three groups according to Agatston score quartile: no AVC (Q2, Score 0, n = 18), mild AVC (Q3, Score 1-2254, n = 24), and severe AVC (Q4 Score >2254, n = 14). In multivariable linear regression, compared to the non AVC group, the mild and severe AVC groups had lower maximum AVA (by -1.71 cm 2 and -2.25 cm 2 , respectively), lower peak positive da/dt (by -21.88 cm 2 /s and -26.65 cm 2 /s, respectively), and higher peak negative da/dt (by 13.78 cm 2 /s and 18.11 cm 2 /s, respectively) (p < 0.05 for all comparisons). AVA and its opening and closing were influenced by leaflet calcification. The present study demonstrates the ability of dynamic MDCT imaging to assess quantitative aortic valve motion in a clinical setting. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  12. Heart valve cardiomyocytes of mouse embryos express the serotonin transporter SERT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pavone, Luigi Michele; Department of Biochemistry and Medical Biotechnologies, University of Naples Federico II, Naples; Spina, Anna

    2008-12-12

    Multiple evidence demonstrate a role for serotonin and its transporter SERT in heart valve development and disease. By utilizing a Cre/loxP system driven by SERT gene expression, we recently demonstrated a regionally restricted distribution of SERT-expressing cells in developing mouse heart. In order to characterize the cell types exhibiting SERT expression within the mouse heart valves at early developmental stages, in this study we performed immunohistochemistry for Islet1 (Isl1) and connexin-43 (Cx-43) on heart sections from SERT{sup Cre/+};ROSA26R embryos previously stained with X-gal. We observed the co-localization of LacZ staining with Isl1 labelling in the outflow tract, the right ventriclemore » and the conal region of E11.5 mouse heart. Cx-43 labelled cells co-localized with LacZ stained cells in the forming atrioventricular valves. These results demonstrate the cardiomyocyte phenotype of SERT-expressing cells in heart valves of the developing mouse heart, thus suggesting an active role of SERT in early heart valve development.« less

  13. Comparison of acute elastic recoil between the SAPIEN-XT and SAPIEN valves in transfemoral-transcatheter aortic valve replacement.

    PubMed

    Garg, Aatish; Parashar, Akhil; Agarwal, Shikhar; Aksoy, Olcay; Hammadah, Muhammad; Poddar, Kanhaiya Lal; Puri, Rishi; Svensson, Lars G; Krishnaswamy, Amar; Tuzcu, E Murat; Kapadia, Samir R

    2015-02-15

    The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.

  14. Technical pitfalls and tips for the valve-in-valve procedure

    PubMed Central

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these

  15. Valve stem and packing assembly

    DOEpatents

    Wordin, John J.

    1991-01-01

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents overtightening of the retaining nut and the resulting excessive friction between stem and stem packing.

  16. Valve stem and packing assembly

    DOEpatents

    Wordin, J.J.

    1991-09-03

    A valve stem and packing assembly is provided in which a rotatable valve stem includes a first tractrix surface for sliding contact with a stem packing and also includes a second tractrix surface for sliding contact with a bonnet. Force is applied by means of a spring, gland flange, and gland on the stem packing so the stem packing seals to the valve stem and bonnet. This configuration serves to create and maintain a reliable seal between the stem packing and the valve stem. The bonnet includes a second complementary tractrix surface for contacting the second sliding tractrix surface, the combination serving as a journal bearing for the entire valve stem and packing assembly. The journal bearing so configured is known as a Schiele's pivot. The Schiele's pivot also serves to maintain proper alignment of the valve stem with respect to the bonnet. Vertical wear between the surfaces of the Schiele's pivot is uniform at all points of contact between the second sliding tractrix surface and the second complementary tractrix surface of a bonnet. The valve stem is connected to a valve plug by means of a slip joint. The valve is opened and closed by rotating the valve stem. The slip joint compensates for wear on the Schiele's pivot and on the valve plug. A ledge is provided on the valve bonnet for the retaining nut to bear against. The ledge prevents over tightening of the retaining nut and the resulting excessive friction between stem and stem packing. 2 figures.

  17. Self-Rupturing Hermetic Valve

    NASA Technical Reports Server (NTRS)

    Tucker, Curtis E., Jr.; Sherrit, Stewart

    2011-01-01

    For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self

  18. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    PubMed

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p < 0.0001), tricuspid valve regurgitation (mean 2.33 vs 1.3, p < 0.0001), and in right ventricular dilation, volume, and area. There was no difference in the degree of tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve

  19. Study on the Regulating Performance of Sliding Regulation-Valve

    NASA Astrophysics Data System (ADS)

    Hu, Wei; Peng, Xiaoyong; Zhang, Yuan; Zheng, Yulan; Zhu, Fangyao

    2018-01-01

    Using a proven reliable method of CFD to study the regulating performance of a sliding regulation valve with a conical spool and rugby body. The numerical simulation results indicate that no matter where the spool is located, the flow field always has a vortex at the center of the valve body; When the spool is at the origin, the vortex and resistance coefficient of the valve are the minimum; When the spool moves from the origin to the right (the opening of the valve becomes smaller) to reach a certain position later, vortex currents also begin to appear around the tube wall behind the orifice. In addition, the vortex increases as the throttling port decreases whereas the resistance coefficient of the valve ascends slowly with the increase of the deviation of the spool and the rise in series; This type of regulating valve has S type (slow at both ends, sensitive at the center) flow characteristics at the stroke, and is not affected by the size of Re.

  20. Association of Low-Density Lipoprotein Cholesterol–Related Genetic Variants With Aortic Valve Calcium and Incident Aortic Stenosis

    PubMed Central

    Smith, J. Gustav; Luk, Kevin; Schulz, Christina-Alexandra; Engert, James C.; Do, Ron; Hindy, George; Rukh, Gull; Dufresne, Line; Almgren, Peter; Owens, David S.; Harris, Tamara B.; Peloso, Gina M.; Kerr, Kathleen F.; Wong, Quenna; Smith, Albert V.; Budoff, Matthew J.; Rotter, Jerome I.; Cupples, L. Adrienne; Rich, Stephen; Kathiresan, Sekar; Orho-Melander, Marju; Gudnason, Vilmundur; O’Donnell, Christopher J.; Post, Wendy S.; Thanassoulis, George

    2014-01-01

    IMPORTANCE Plasma low-density lipoprotein cholesterol (LDL-C) has been associated with aortic stenosis in observational studies; however, randomized trials with cholesterol-lowering therapies in individuals with established valve disease have failed to demonstrate reduced disease progression. OBJECTIVE To evaluate whether genetic data are consistent with an association between LDL-C, high-density lipoprotein cholesterol (HDL-C), or triglycerides (TG) and aortic valve disease. DESIGN, SETTING, AND PARTICIPANTS Using a Mendelian randomization study design, we evaluated whether weighted genetic risk scores (GRSs), a measure of the genetic predisposition to elevations in plasma lipids, constructed using single-nucleotide polymorphisms identified in genome-wide association studies for plasma lipids, were associated with aortic valve disease. We included community-based cohorts participating in the CHARGE consortium (n = 6942), including the Framingham Heart Study (cohort inception to last follow-up: 1971-2013; n = 1295), Multi-Ethnic Study of Atherosclerosis (2000-2012; n = 2527), Age Gene/Environment Study-Reykjavik (2000-2012; n = 3120), and the Malmö Diet and Cancer Study (MDCS, 1991-2010; n = 28 461). MAIN OUTCOMES AND MEASURES Aortic valve calcium quantified by computed tomography in CHARGE and incident aortic stenosis in the MDCS. RESULTS The prevalence of aortic valve calcium across the 3 CHARGE cohorts was 32% (n = 2245). In the MDCS, over a median follow-up time of 16.1 years, aortic stenosis developed in 17 per 1000 participants (n = 473) and aortic valve replacement for aortic stenosis occurred in 7 per 1000 (n = 205). Plasma LDL-C, but not HDL-C or TG, was significantly associated with incident aortic stenosis (hazard ratio [HR] per mmol/L, 1.28; 95% CI, 1.04-1.57; P = .02; aortic stenosis incidence: 1.3% and 2.4% in lowest and highest LDL-C quartiles, respectively). The LDL-C GRS, but not HDL-C or TG GRS, was significantly associated with presence of