Sample records for valve leaflets evoke

  1. Prosthetic Mitral Valve Leaflet Escape

    PubMed Central

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  2. Absence of posterior tricuspid valve leaflet and valve reconstruction

    PubMed Central

    Komoda, Takeshi; Stamm, Christof; Fleck, Eckart; Hetzer, Roland

    2012-01-01

    We report a rare case of the absence of a posterior tricuspid valve leaflet. A male patient, aged 46, suffering from severe tricuspid valve regurgitation (TR) of unknown aetiology and atrial septal aneurysm was referred to our hospital for surgery. On surgical inspection, the posterior tricuspid valve leaflet and its subvalvular apparatus were completely absent and only the valve annulus was seen in the corresponding position. The anterior and septal leaflets were normal. We successfully reconstructed the tricuspid valve as follows: the head of an anterior papillary muscle was approximated to the ventricular septum (Sebening stitch). After the approximation of the centre of the tricuspid annulus of the anterior leaflet to the tricuspid annulus on the opposite side, a sizer of 29 mm in diameter was easily passed through the anterior orifice. The posterior orifice was closed with running sutures (posterior annulorrhaphy after Hetzer). Before these procedures, we attempted to reconstruct the tricuspid valve with a posterior annulorrhaphy alone; however, valve competence was insufficient. A Sebening stitch was necessary to improve the valve competence. Echocardiography showed TR grade 1 at the patient's discharge from hospital and TR grade 1 to 2 at the follow-up, 10 months after the operation. PMID:22419794

  3. Optimal Elastomeric Scaffold Leaflet Shape for Pulmonary Heart Valve Leaflet Replacement

    PubMed Central

    Fan, Rong; Bayoumi, Ahmed S.; Chen, Peter; Hobson, Christopher M.; Wagner, William R.; Mayer, John E.; Sacks, Michael S.

    2012-01-01

    Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery. PMID:23294966

  4. Melanocyte pigmentation stiffens murine cardiac tricuspid valve leaflet

    PubMed Central

    Balani, Kantesh; Brito, Flavia C.; Kos, Lidia; Agarwal, Arvind

    2009-01-01

    Pigmentation of murine cardiac tricuspid valve leaflet is associated with melanocyte concentration, which affects its stiffness. Owing to its biological and viscoelastic nature, estimation of the in situ stiffness measurement becomes a challenging task. Therefore, quasi-static and nanodynamic mechanical analysis of the leaflets of the mouse tricuspid valve is performed in the current work. The mechanical properties along the leaflet vary with the degree of pigmentation. Pigmented regions of the valve leaflet that contain melanocytes displayed higher storage modulus (7–10 GPa) than non-pigmented areas (2.5–4 GPa). These results suggest that the presence of melanocytes affects the viscoelastic properties of the mouse atrioventricular valves and are important for their proper functioning in the organism. PMID:19586956

  5. Transcatheter valve underexpansion limits leaflet durability: implications for valve-in-valve procedures

    PubMed Central

    Martin, Caitlin; Sun, Wei

    2016-01-01

    Transcatheter aortic valve (TAV) implantation within a failed bioprosthetic valve is a growing trend for high-risk patients. The non-compliant stent of the previous prosthesis may prevent full expansion of the TAV, which has been shown to distort the leaflet configuration, and has been hypothesized to adversely affect durability. In this study, TAV leaflet fatigue damage under cyclic pressurization in the setting of stent underexpansion by 0 (fully expanded), 1, 2 and 3 mm was simulated using finite element analysis to test this hypothesis. In the 2 and 3 mm underexpanded devices, the TAV leaflets exhibited severe pin-wheeling during valve closure, which increased leaflet stresses dramatically, and resulted in accelerated fatigue damage of the leaflets. The leaflet fatigue damage in the 1 mm underexpanded case was similar to that in the fully expanded case. Clinically a range of 10% to 15% underexpansion is generally considered acceptable; however, it was observed in this study that ≥2 mm (≥9.1%) underexpansion, will significantly impact device durability. Further study is necessary to determine the impact of various deployment conditions, i.e. non-uniform and non-circular deployments and different implantation heights, on differing TAV devices, but it is clear that the normal TAV leaflet configuration must be preserved in order to preserve durability. PMID:27734178

  6. Leaflet escape in a new bileaflet mechanical valve: TRI technologies.

    PubMed

    Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino

    2003-05-13

    Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.

  7. Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.

    PubMed

    Xuan, Yue; Krishnan, Kapil; Ye, Jian; Dvir, Danny; Guccione, Julius M; Ge, Liang; Tseng, Elaine E

    2017-05-01

    Transcatheter aortic valve replacement is established therapy for high-risk and inoperable patients with severe aortic stenosis, but questions remain regarding long-term durability. Valve design influences durability. Increased leaflet stresses in surgical bioprostheses have been correlated with degeneration; however, transcatheter valve leaflet stresses are unknown. From 2007 to 2014, a majority of US patients received first-generation balloon-expandable transcatheter valves. Our goal was to determine stent and leaflet stresses in this valve design using finite element analyses. A 26-mm Sapien Transcatheter Heart Valve (Edwards Lifesciences, Inc, Irvine, Calif) underwent high-resolution microcomputed tomography scanning to develop precise 3-dimensional geometry of the leaflets, the stent, and the polyethylene terephthalate elements. The stent was modeled using 3-dimensional elements and the leaflets were modeled using shell elements. Stent material properties were based on stainless steel, whereas those for leaflets were obtained from surgical bioprostheses. Noncylindrical Sapien valve geometry was also simulated. Pressure loading to 80 mm Hg and 120 mm Hg was performed using ABAQUS finite element software (Dassault Systèmes, Waltham, Mass). At 80 mm Hg, maximum principal stresses on Sapien leaflets were 1.31 megaspascals (MPa). Peak leaflet stress was observed at commissural tips where leaflets connected to the stent. Maximum principal stresses for the stent were 188.91 MPa and located at stent tips where leaflet commissures were attached. Noncylindrical geometry increased peak principal leaflet stresses by 16%. Using exact geometry from high-resolution scans, the 26-mm Sapien Transcatheter Heart Valve showed that peak stresses for both stent and leaflets were present at commissural tips where leaflets were attached. These regions would be prone to leaflet degeneration. Understanding stresses in first-generation transcatheter valves allows comparison to

  8. Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

    PubMed

    Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari

    2017-06-01

    Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.

  9. On the bending properties of porcine mitral, tricuspid, aortic, and pulmonary valve leaflets.

    PubMed

    Brazile, Bryn; Wang, Bo; Wang, Guangjun; Bertucci, Robbin; Prabhu, Raj; Patnaik, Sourav S; Butler, J Ryan; Claude, Andrew; Brinkman-Ferguson, Erin; Williams, Lakiesha N; Liao, Jun

    2015-01-01

    The atrioventricular valve leaflets (mitral and tricuspid) are different from the semilunar valve leaflets (aortic and pulmonary) in layered structure, ultrastructural constitution and organization, and leaflet thickness. These differences warrant a comparative look at the bending properties of the four types of leaflets. We found that the moment-curvature relationships in atrioventricular valves were stiffer than in semilunar valves, and the moment-curvature relationships of the left-side valve leaflets were stiffer than their morphological analog of the right side. These trends were supported by the moment-curvature curves and the flexural rigidity analysis (EI value decreased from mitral, tricuspid, aortic, to pulmonary leaflets). However, after taking away the geometric effect (moment of inertia I), the instantaneous effective bending modulus E showed a reversed trend. The overall trend of flexural rigidity (EI: mitral > tricuspid > aortic > pulmonary) might be correlated with the thickness variations among the four types of leaflets (thickness: mitral > tricuspid > aortic > pulmonary). The overall trend of the instantaneous effective bending modulus (E: mitral < tricuspid < aortic < pulmonary) might be correlated to the layered fibrous ultrastructures of the four types of leaflets, of which the fibers in mitral and tricuspid leaflets were less aligned, and the fibers in aortic and pulmonary leaflets were highly aligned. We also found that, for all types of leaflets, moment-curvature relationships are stiffer in against-curvature (AC) bending than in with-curvature bending (WC), which implies that leaflets tend to flex toward their natural curvature and comply with blood flow. Lastly, we observed that the leaflets were stiffer in circumferential bending compared with radial bending, likely reflecting the physiological motion of the leaflets, i.e., more bending moment and movement were experienced in radial direction than circumferential direction.

  10. Determination of correlation between backflow volume and mitral valve leaflet young modulus from two dimensional echocardiogram images

    NASA Astrophysics Data System (ADS)

    Jong, Rudiyanto P.; Osman, Kahar; Adib, M. Azrul Hisham M.

    2012-06-01

    Mitral valve prolapse without proper monitoring might lead to a severe mitral valve failure which eventually leads to a sudden death. Additional information on the mitral valve leaflet condition against the backflow volume would be an added advantage to the medical practitioner for their decision on the patients' treatment. A study on two dimensional echocardiography images has been conducted and the correlations between the backflow volume of the mitral regurgitation and mitral valve leaflet Young modulus have been obtained. Echocardiogram images were analyzed on the aspect of backflow volume percentage and mitral valve leaflet dimensions on different rates of backflow volume. Young modulus values for the mitral valve leaflet were obtained by using the principle of elastic deflection and deformation on the mitral valve leaflet. The results show that the backflow volume increased with the decrease of the mitral valve leaflet Young modulus which also indicate the condition of the mitral valve leaflet approaching failure at high backflow volumes. Mitral valve leaflet Young modulus values obtained in this study agreed with the healthy mitral valve leaflet Young modulus from the literature. This is an initial overview of the trend on the prediction of the behaviour between the fluid and the structure of the blood and the mitral valve which is extendable to a larger system of prediction on the mitral valve leaflet condition based on the available echocardiogram images.

  11. Effects of Leaflet Design on Transvalvular Gradients of Bioprosthetic Heart Valves.

    PubMed

    Dabiri, Yaghoub; Ronsky, Janet; Ali, Imtiaz; Basha, Ameen; Bhanji, Alisha; Narine, Kishan

    2016-12-01

    Bioprosthetic aortic valves (BAVs) are becoming the prostheses of choice in heart valve replacement. The objective of this paper is to assess the effects of leaflet geometry on the mechanics and hemodynamics of BAVs in a fluid structure interaction model. The curvature and angle of leaflets were varied in 10 case studies whereby the following design parameters were altered: a circular arch, a line, and a parabola for the radial curvature, and a circular arch, a spline, and a parabola for the circumferential curvature. Six different leaflet angles (representative of the inclination of the leaflets toward the surrounding aortic wall) were analyzed. The 3-dimensional geometry of the models were created using SolidWorks, Pointwise was used for meshing, and Comsol Multiphysics was used for implicit finite element calculations. Realistic loading was enforced by considering the time-dependent strongly-coupled interaction between blood flow and leaflets. Higher mean pressure gradients as well as von Mises stresses were obtained with a parabolic or circular curvature for radial curvature or a parabolic or spline curvature for the circumferential curvature. A smaller leaflet angle was associated with a lower pressure gradient, and, a lower von Mises stress. The leaflet curvature and angle noticeably affected the speed of valve opening, and closing. When a parabola was used for circumferential or radial curvature, leaflets displacements were asymmetric, and they opened and closed more slowly. A circular circumferential leaflet curvature, a linear leaflet radial curvature, and leaflet inclination toward the surrounding aortic wall were associated with superior BAVs mechanics.

  12. Further insights into normal aortic valve function: role of a compliant aortic root on leaflet opening and valve orifice area.

    PubMed

    Sripathi, Vangipuram Canchi; Kumar, Ramarathnam Krishna; Balakrishnan, Komarakshi R

    2004-03-01

    This study aims to find the fundamental differences in the mechanism of opening and closing of a normal aortic valve and a valve with a stiff root, using a dynamic finite element model. A dynamic, finite element model with time varying pressure was used in this study. Shell elements with linear elastic properties for the leaflet and root were used. Two different cases were analyzed: (1) normal leaflets inside a compliant root, and (2) normal leaflets inside a stiff root. A compliant aortic root contributes substantially to the smooth and symmetrical leaflet opening with minimal gradients. In contrast, the leaflet opening inside a stiff root is delayed, asymmetric, and wrinkled. However, this wrinkling is not associated with increased leaflet stresses. In compliant roots, the effective valve orifice area can substantially increase because of increased root pressure and transvalvular gradients. In stiff roots this effect is strikingly absent. A compliant aortic root contributes substantially to smooth and symmetrical leaflet opening with minimal gradients. The compliance also contributes much to the ability of the normal aortic valve to increase its effective valve orifice in response to physiologic demands of exercise. This effect is strikingly absent in stiff roots.

  13. Congenital uni-leaflet mitral valve with severe stenosis: A case report with literature review.

    PubMed

    Zhang, Weixin; Wang, Yonghuai; Ma, Chunyan; Zhang, Zhiwei; Yang, Jun

    2017-03-01

    Numerical abnormalities of mitral leaflets is a special entity in congenital mitral malformations. Previously reported cases of uni-leaflet mitral valve were primarily related to absence or dysplasia of certain leaflets. We present a case here with mitral leaflets that were not divided into anterior and posterior as usual, but developed as an integral structure instead, which is different from previously documented cases of uni-leaflet mitral valves. Real time three-dimensional echocardiography (RT3DE) provides a visual presentation of the abnormal mitral structure which was confirmed by surgical operation. To the best of our knowledge, this unusual form of uni-leaflet mitral valve has not been reported yet. © 2017, Wiley Periodicals, Inc.

  14. Randomised trial of mitral valve repair with leaflet resection versus leaflet preservation on functional mitral stenosis (The CAMRA CardioLink-2 Trial).

    PubMed

    Chan, Vincent; Chu, Michael W A; Leong-Poi, Howard; Latter, David A; Hall, Judith; Thorpe, Kevin E; de Varennes, Benoit E; Quan, Adrian; Tsang, Wendy; Dhingra, Natasha; Yared, Kibar; Teoh, Hwee; Chu, F Victor; Chan, Kwan-Leung; Mesana, Thierry G; Connelly, Kim A; Ruel, Marc; Jüni, Peter; Mazer, C David; Verma, Subodh

    2017-05-30

    The gold-standard treatment of severe mitral regurgitation (MR) due to degenerative disease is valve repair, which is surgically performed with either a leaflet resection or leaflet preservation approach. Recent data suggest that functional mitral stenosis (MS) may occur following valve repair using a leaflet resection strategy, which adversely affects patient prognosis. A randomised comparison of these two approaches to mitral repair on functional MS has not been conducted. This is a prospective, multicentre randomised controlled trial designed to test the hypothesis that leaflet preservation leads to better preservation of mitral valve geometry, and therefore, will be superior to leaflet resection for the primary outcome of functional MS as assessed by 12-month mean mitral valve gradient at peak exercise. Eighty-eight patients with posterior leaflet prolapse will be randomised intraoperatively once deemed by the operating surgeon to feasibly undergo mitral repair using either a leaflet resection or leaflet preservation approach. Secondary end points include comparison of repair strategies with regard to mitral valve orifice area, leaflet coaptation height, 6 min walk test and a composite major adverse event end point consisting of recurrent MR ≥2+, death or hospital readmission for congestive heart failure within 12 months of surgery. Institutional ethics approval has been obtained from all enrolling sites. Overall, there remains clinical equipoise regarding the mitral valve repair strategy that is associated with the least likelihood of functional MS. This trial hopes to introduce high-quality evidence to help surgical decision making in this context. NCT02552771. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    PubMed

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Measurement and reconstruction of the leaflet geometry for a pericardial artificial heart valve.

    PubMed

    Jiang, Hongjun; Campbell, Gord; Xi, Fengfeng

    2005-03-01

    This paper describes the measurement and reconstruction of the leaflet geometry for a pericardial heart valve. Tasks involved include mapping the leaflet geometries by laser digitizing and reconstructing the 3D freeform leaflet surface based on a laser scanned profile. The challenge is to design a prosthetic valve that maximizes the benefits offered to the recipient as compared to the normally operating naturally-occurring valve. This research was prompted by the fact that artificial heart valve bioprostheses do not provide long life durability comparable to the natural heart valve, together with the anticipated benefits associated with defining the valve geometries, especially the leaflet geometries for the bioprosthetic and human valves, in order to create a replicate valve fabricated from synthetic materials. Our method applies the concept of reverse engineering in order to reconstruct the freeform surface geometry. A Brown & Shape coordinate measuring machine (CMM) equipped with a HyMARC laser-digitizing system was used to measure the leaflet profiles of a Baxter Carpentier-Edwards pericardial heart valve. The computer software, Polyworks was used to pre-process the raw data obtained from the scanning, which included merging images, eliminating duplicate points, and adding interpolated points. Three methods, creating a mesh model from cloud points, creating a freeform surface from cloud points, and generating a freeform surface by B-splines are presented in this paper to reconstruct the freeform leaflet surface. The mesh model created using Polyworks can be used for rapid prototyping and visualization. To fit a freeform surface to cloud points is straightforward but the rendering of a smooth surface is usually unpredictable. A surface fitted by a group of B-splines fitted to cloud points was found to be much smoother. This method offers the possibility of manually adjusting the surface curvature, locally. However, the process is complex and requires additional

  17. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    PubMed

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  18. Impact of Clinically Relevant Elliptical Deformations on the Damage Patterns of Sagging and Stretched Leaflets in a Bioprosthetic Heart Valve.

    PubMed

    Sritharan, Deepa; Fathi, Parinaz; Weaver, Jason D; Retta, Stephen M; Wu, Changfu; Duraiswamy, Nandini

    2018-06-12

    After implantation of a transcatheter bioprosthetic heart valve its original circular circumference may become distorted, which can lead to changes in leaflet coaptation and leaflets that are stretched or sagging. This may lead to early structural deterioration of the valve as seen in some explanted transcatheter heart valves. Our in vitro study evaluates the effect of leaflet deformations seen in elliptical configurations on the damage patterns of the leaflets, with circular valve deformation as the control. Bovine pericardial tissue heart valves were subjected to accelerated wear testing under both circular (N = 2) and elliptical (N = 4) configurations. The elliptical configurations were created by placing the valve inside custom-made elliptical holders, which caused the leaflets to sag or stretch. The hydrodynamic performance of the valves was monitored and high resolution images were acquired to evaluate leaflet damage patterns over time. In the elliptically deformed valves, sagging leaflets experienced more damage from wear compared to stretched leaflets; the undistorted leaflets of the circular valves experienced the least leaflet damage. Free-edge thinning and tearing were the primary modes of damage in the sagging leaflets. Belly region thinning was seen in the undistorted and stretched leaflets. Leaflet and fabric tears at the commissures were seen in all valve configurations. Free-edge tearing and commissure tears were the leading cause of valve hydrodynamic incompetence. Our study shows that mechanical wear affects heart valve pericardial leaflets differently based on whether they are undistorted, stretched, or sagging in a valve configuration. Sagging leaflets are more likely to be subjected to free-edge tear than stretched or undistorted leaflets. Reducing leaflet stress at the free edge of non-circular valve configurations should be an important factor to consider in the design and/or deployment of transcatheter bioprosthetic heart valves to

  19. A new self-expandable aortic valved stent deployed above native leaflets for aortic insufficiency: an in vitro study.

    PubMed

    Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y

    2012-12-01

    The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.

  20. INTERLAYER MICROMECHANICS OF THE AORTIC HEART VALVE LEAFLET

    PubMed Central

    Buchanan, Rachel M.; Sacks, Michael S.

    2014-01-01

    While the mechanical behaviors of the fibrosa and ventricularis layers of the aortic valve (AV) leaflet are understood, little information exists on their mechanical interactions mediated by the GAG-rich central spongiosa layer. Parametric simulations of the interlayer interactions of the AV leaflets in flexure utilized a tri-layered finite element (FE) model of circumferentially oriented tissue sections to investigate inter-layer sliding hypothesized to occur. Simulation results indicated that the leaflet tissue functions as a tightly bonded structure when the spongiosa effective modulus was at least 25% that of the fibrosa and ventricularis layers. Novel studies that directly measured transmural strain in flexure of AV leaflet tissue specimens validated these findings. Interestingly, a smooth transmural strain distribution indicated that the layers of the leaflet indeed act as a bonded unit, consistent with our previous observations (Stella and Sacks, 2007) of a large number of transverse collagen fibers interconnecting the fibrosa and ventricularis layers. Additionally, when the tri-layered FE model was refined to match the transmural deformations, a layer-specific bimodular material model (resulting in four total moduli) accurately matched the transmural strain and moment-curvature relations simultaneously. Collectively, these results provide evidence, contrary to previous assumptions, that the valve layers function as a bonded structure in the low-strain flexure deformation mode. Most likely, this results directly from the transverse collagen fibers that bind the layers together to disable physical sliding and maintain layer residual stresses. Further, the spongiosa may function as a general dampening layer while the AV leaflets deforms as a homogenous structure despite its heterogeneous architecture. PMID:24292631

  1. Posterior leaflet preservation during mitral valve replacement for rheumatic mitral stenosis.

    PubMed

    Djukić, P L; Obrenović-Kirćanski, B B; Vranes, M R; Kocica, M J; Mikić, A Dj; Velinović, M M; Kacar, S M; Kovacević, N S; Parapid, B J

    2006-01-01

    Mitral valve replacement with posterior leaflet preservation was shown beneficial for postoperative left vetricular (LV) performance in patients with mitral regurgitation. Some authors find it beneficial even for the long term LV function. We investigated a long term effect of this technique in patients with rheumatic mitral stenosis. We studied 20 patents with mitral valve replacement due to rheumatic mitral stenosis, in the period from January 1988 to December 1989. In group A (10 patients) both leaflets and coresponding chordal excision was performed, while in group B (10 patients) the posterior leaflet was preserved. In all patients a Carbomedics valve was inserted. We compared clinical pre and postoperative status, as well as hemodynamic characteristics of the valve and left ventricle in both groups. Control echocardiographyc analysis included: maximal (PG) and mean (MG) gradients; effective valve area (AREA); telediastolic (TDV) and telesystolic (TSV) LV volume; stroke volume (SV); ejection fraction (EF); fractional shortening (FS) and segmental LV motion. The mean size of inserted valve was 26.6 in group A and 27.2 in group B. Hemodynamic data: PG (10.12 vs 11.1); MG (3.57 vs 3.87); AREA (2.35 vs 2.30); TDV 126.0 vs 114.5); TSV (42.2 vs 36.62); SV (83.7 vs 77.75); EF (63.66 vs 67.12); FS (32.66 vs 38.25). Diaphragmal segmental hypokinesis was evident in one patient from group A and in two patients from group B. In patients with rheumatic stenosis, posterior leaflet preservation did not have increased beneficial effect on left ventricular performance during long-term follow-up. An adequate posterior leaflet preservation does not change hemodynamic valvular characteristics even after long-term follow-up.

  2. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    PubMed

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  3. Flail anterior tricuspid valve leaflet in a neonate: association with maternal antiphospholipid syndrome.

    PubMed

    Tarca, Adrian J; Eckersley, Luke; Kothari, Darshan

    2017-10-01

    This brief report describes a case of flail anterior tricuspid valve leaflet in a neonate associated with maternal antiphospholipid syndrome. Fetal echocardiography at 27 weeks of gestation showed competent atrioventricular valves with biventricular echogenic chordae. Fetal distress was noted at delivery, and echocardiography showed a flail anterior leaflet of the tricuspid valve with severe regurgitation. Possible causation and implications of maternal antiphospholipid syndrome are discussed.

  4. Congenital absence of pulmonary valve leaflets.

    PubMed Central

    Buendia, A; Attie, F; Ovseyevitz, J; Zghaib, A; Zamora, C; Zavaleta, D; Vargas-Barron, J; Richheimer, R

    1983-01-01

    Congenital absence of pulmonary valve leaflets is an uncommon condition usually associated with ventricular septal defect and an obstructive pulmonary valve ring. Twenty-one patients with these malformations are described. Twenty had an associated ventricular septal defect with ventriculoarterial concordance, and one also had transposition of the great arteries, ventricular septal defect, and obstructive pulmonary valve ring. The clinical features, cardiac catheterisation findings, and angiocardiographic results are presented. Twelve patients underwent cardiac surgery. Three patients died, one in the early, and the other two in the late postoperative period. The results, according to the surgical technique employed and postoperative cardiac catheterisation findings, showed that patients in whom the bioprostheses were implanted in the pulmonary position had a better late follow-up. Images PMID:6860509

  5. Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement

    PubMed Central

    Gunning, Paul S.; Saikrishnan, Neelakantan; Yoganathan, Ajit P.; McNamara, Laoise M.

    2015-01-01

    Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a ‘peel-back’ leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve. PMID:26674192

  6. Simulation of Blood flow in Different Configurations Design of Bi-leaflet Mechanical Heart Valve

    NASA Astrophysics Data System (ADS)

    Hafizah Mokhtar, N.; Abas, Aizat

    2018-05-01

    In this work, two different designs of artificial heart valve were devised and then compared by considering the thrombosis, wear and valve orifice to anatomical orifice ratio of each mechanical heart valve. These different design configurations of bi-leaflet mechanical heart valves model are created through the use of Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. Design 1 is based on existing conventional bi-leaflet valve and design 2 based on modified bi-leaflet respectively. The flow pattern, velocity, vorticity and stress analysis have been done to justify the best design. Based on results, both of the designs show a Doppler velocity index of less than the allowable standard of 2.2 which is safe to be used as replacement of the human heart valve. However, design 2 shows that it has a lower possibility of cavitation issue which will lead to lower thrombosis and provide good central flow area of blood as compared to design 1.

  7. Microstructured Nickel-Titanium Thin Film Leaflets for Hybrid Tissue Engineered Heart Valves Fabricated by Magnetron Sputter Deposition.

    PubMed

    Loger, K; Engel, A; Haupt, J; Lima de Miranda, R; Lutter, G; Quandt, E

    2016-03-01

    Heart valves are constantly exposed to high dynamic loading and are prone to degeneration. Therefore, it is a challenge to develop a durable heart valve substitute. A promising approach in heart valve engineering is the development of hybrid scaffolds which are composed of a mechanically strong inorganic mesh enclosed by valvular tissue. In order to engineer an efficient, durable and very thin heart valve for transcatheter implantations, we developed a fabrication process for microstructured heart valve leaflets made from a nickel-titanium (NiTi) thin film shape memory alloy. To examine the capability of microstructured NiTi thin film as a matrix scaffold for tissue engineered hybrid heart valves, leaflets were successfully seeded with smooth muscle cells (SMCs). In vitro pulsatile hydrodynamic testing of the NiTi thin film valve leaflets demonstrated that the SMC layer significantly improved the diastolic sufficiency of the microstructured leaflets, without affecting the systolic efficiency. Compared to an established porcine reference valve model, magnetron sputtered NiTi thin film material demonstrated its suitability for hybrid tissue engineered heart valves.

  8. Prediction of oxygen distribution in aortic valve leaflet considering diffusion and convection.

    PubMed

    Wang, Ling; Korossis, Sotirios; Fisher, John; Ingham, Eileen; Jin, Zhongmin

    2011-07-01

    Oxygen supply and transport is an important consideration in the development of tissue engineered constructs. Previous studies from our group have focused on the effect of tissue thickness on the oxygen diffusion within a three-dimensional aortic valve leaflet model, and highlighted the necessity for additional transport mechanisms such as oxygen convection. The aims of this study were to investigate the effect of interstitial fluid flow within the aortic valve leaflet, induced by the cyclic loading of the leaflet, on oxygen transport. Indentation testing and finite element modelings were employed to derive the biphasic properties of the leaflet tissue. The biphasic properties were subsequently used in the computational modeling of oxygen convection in the leaflet, which was based on the effective interstitial fluid velocity and the tissue deformation. Subsequently, the oxygen profile was predicted within the valve leaflet model by solving the diffusion and convection equation simultaneously utilizing the finite difference method. The compression modulus (E) and hydraulic permeability were determined by adapting a finite element model to the experimental indentation test on valvular tissue, E = 0.05MPa, and k =2.0 mm4/Ns. Finite element model of oxygen convection in valvular tissue incorporating the predicted biphasic properties was developed and the interstitial fluid flow rate was calculated falling in range of 0.025-0.25 mm/s depending on the tissue depth. Oxygen distribution within valvular tissue was predicted using one-dimensional oxygen diffusion model taking into consider the interstitial fluid effect. It was found that convection did enhance the oxygen transport in valvular tissue by up to 68% increase in the minimum oxygen tension within the tissue, depending on the strain level of the tissue as reaction of the magnitude and frequencies of the cardiac loading. The effective interstitial fluid velocity was found to play an important role in enhancing the

  9. Comprehensive 4-stage categorization of bicuspid aortic valve leaflet morphology by cardiac MRI in 386 patients.

    PubMed

    Murphy, I G; Collins, J; Powell, A; Markl, M; McCarthy, P; Malaisrie, S C; Carr, J C; Barker, A J

    2017-08-01

    Bicuspid aortic valve (BAV) disease is heterogeneous and related to valve dysfunction and aortopathy. Appropriate follow up and surveillance of patients with BAV may depend on correct phenotypic categorization. There are multiple classification schemes, however a need exists to comprehensively capture commissure fusion, leaflet asymmetry, and valve orifice orientation. Our aim was to develop a BAV classification scheme for use at MRI to ascertain the frequency of different phenotypes and the consistency of BAV classification. The BAV classification scheme builds on the Sievers surgical BAV classification, adding valve orifice orientation, partial leaflet fusion and leaflet asymmetry. A single observer successfully applied this classification to 386 of 398 Cardiac MRI studies. Repeatability of categorization was ascertained with intraobserver and interobserver kappa scores. Sensitivity and specificity of MRI findings was determined from operative reports, where available. Fusion of the right and left leaflets accounted for over half of all cases. Partial leaflet fusion was seen in 46% of patients. Good interobserver agreement was seen for orientation of the valve opening (κ = 0.90), type (κ = 0.72) and presence of partial fusion (κ = 0.83, p < 0.0001). Retrospective review of operative notes showed sensitivity and specificity for orientation (90, 93%) and for Sievers type (73, 87%). The proposed BAV classification schema was assessed by MRI for its reliability to classify valve morphology in addition to illustrating the wide heterogeneity of leaflet size, orifice orientation, and commissural fusion. The classification may be helpful in further understanding the relationship between valve morphology, flow derangement and aortopathy.

  10. Simulated transcatheter aortic valve deformation: A parametric study on the impact of leaflet geometry on valve peak stress.

    PubMed

    Li, Kewei; Sun, Wei

    2017-03-01

    In this study, we developed a computational framework to investigate the impact of leaflet geometry of a transcatheter aortic valve (TAV) on the leaflet stress distribution, aiming at optimizing TAV leaflet design to reduce its peak stress. Utilizing a generic TAV model developed previously [Li and Sun, Annals of Biomedical Engineering, 2010. 38(8): 2690-2701], we first parameterized the 2D leaflet geometry by mathematical equations, then by perturbing the parameters of the equations, we could automatically generate a new leaflet design, remesh the 2D leaflet model and build a 3D leaflet model from the 2D design via a Python script. Approximately 500 different leaflet designs were investigated by simulating TAV closure under the nominal circular deployment and physiological loading conditions. From the simulation results, we identified a new leaflet design that could reduce the previously reported valve peak stress by about 5%. The parametric analysis also revealed that increasing the free edge width had the highest overall impact on decreasing the peak stress. A similar computational analysis was further performed for a TAV deployed in an abnormal, asymmetric elliptical configuration. We found that a minimal free edge height of 0.46 mm should be adopted to prevent central backflow leakage. This increase of the free edge height resulted in an increase of the leaflet peak stress. Furthermore, the parametric study revealed a complex response surface for the impact of the leaflet geometric parameters on the peak stress, underscoring the importance of performing a numerical optimization to obtain the optimal TAV leaflet design. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties

    PubMed Central

    Martin, Caitlin

    2014-01-01

    One of the major failure modes of bioprosthetic heart valves (BHVs) is noncalcific structural deterioration due to fatigue of the tissue leaflets; yet, the mechanisms of fatigue are not well understood. BHV durability is primarily assessed based on visual inspection of the leaflets following accelerated wear testing. In this study, we developed a computational framework to simulate BHV leaflet fatigue, which is both efficient and quantitative, making it an attractive alternative to traditional accelerated wear testing. We utilize a phenomenological soft tissue fatigue damage model developed previously to describe the stress softening and permanent set of the glutaraldehyde-treated bovine pericardium leaflets in BHVs subjected to cyclic loading. A parametric study was conducted to determine the effects of altered leaflet and stent elastic properties on the fatigue of the leaflets. The simulation results show that heterogeneity of the leaflet elastic properties, poor leaflet coaptation, and little stent-tip deflection may accelerate leaflet fatigue, which agrees with clinical findings. Therefore, the developed framework may be an invaluable tool for evaluating leaflet durability in new tissue valve designs, including traditional BHVs as well as new transcatheter valves. PMID:24092257

  12. Influence of aortic valve leaflet calcification on dynamic aortic valve motion assessed by cardiac computed tomography.

    PubMed

    Minami, Keisuke; Yoneyama, Kihei; Izumo, Masaki; Suzuki, Kengo; Ogawa, Yasuyoshi; Chikaraishi, Kousuke; Ogawa, Yukihisa; Kobayashi, Yasuyuki; Furukawa, Toshiyuki; Tanabe, Yasuhiro; Akashi, Yoshihiro J

    Computed tomography is the best noninvasive imaging modality for evaluating valve leaflet calcification. To evaluate the association of aortic valve leaflet calcification with instantaneous valve opening and closing using dynamic multidetector computed tomography (MDCT). We retrospectively evaluated 58 consecutive patients who underwent dynamic MDCT imaging. Aortic valve calcification (AVC) was quantified using the Agatston method. The aortic valve area (AVA) tracking curves were derived by planimetry during the cardiac cycle using all 20 phases (5% reconstruction). da/dt in cm 2 /s was calculated as the rate of change of AVA during opening (positive) or closing (negative). Patients were divided into 3 three groups according to Agatston score quartile: no AVC (Q2, Score 0, n = 18), mild AVC (Q3, Score 1-2254, n = 24), and severe AVC (Q4 Score >2254, n = 14). In multivariable linear regression, compared to the non AVC group, the mild and severe AVC groups had lower maximum AVA (by -1.71 cm 2 and -2.25 cm 2 , respectively), lower peak positive da/dt (by -21.88 cm 2 /s and -26.65 cm 2 /s, respectively), and higher peak negative da/dt (by 13.78 cm 2 /s and 18.11 cm 2 /s, respectively) (p < 0.05 for all comparisons). AVA and its opening and closing were influenced by leaflet calcification. The present study demonstrates the ability of dynamic MDCT imaging to assess quantitative aortic valve motion in a clinical setting. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  13. Engineering tissue constructs to mimic native aortic and pulmonary valve leaflets' structures and mechanics

    NASA Astrophysics Data System (ADS)

    Masoumi, Nafiseh

    There are several disadvantages correlated with current heart valve replacement, including anticoagulation therapy for patients with mechanical valves and the low durability of bioprosthetic valves. The non-viable nature of such devices is a critical drawback especially for pediatric cases due to the inability of the graft to grow in vivo with the patients. A tissue engineered heart valve (TEHV) with remodeling and growth ability, is conceptually appealing to use in the surgical repair and could serve as a permanent replacements when operating for pediatric valvular lesions. It is critical that scaffolds for functional heart valve tissue engineering, be capable of mimicking the native leaflet's structure and mechanical properties at the time of implantation. Meanwhile, the scaffolds should be able to support cellular proliferation and native-like tissue formation as the TEHV remodels toward a scaffold-free state. Our overall hypothesis is that an "ideal" engineered construct, designed based on native leaflet's structure and mechanics, will complement a native heart valve leaflet in providing benchmarks for use in the design of clinically-applicable TEHV. This hypothesis was addressed through several experiments conducted in the present study. To establish a functional biomimetic TEHV, we developed scaffolds capable of matching the anisotropic stiffness of native leaflet while promoting native-like cell and collagen content and supporting the ECM generation. Scaffolds with various polymer contents (e.g., poly (glycerol sebacate) (PGS) and poly (epsilon-caprolactone) (PCL)) and structural designs (e.g., microfabricated and microfibrous scaffolds), were fabricated based on native leaflet's structure and mechanics. It was found that the tri-layered scaffold, designed with assembly of microfabricated PGS and microfibrous PGS/PCL was a functional leaflet capable of promoting tissue formation. Furthermore, to investigate the effect of cyclic stress and flexure

  14. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    PubMed

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  15. The Fluid Mechanics of Transcatheter Heart Valve Leaflet Thrombosis in the Neosinus.

    PubMed

    Midha, Prem A; Raghav, Vrishank; Sharma, Rahul; Condado, Jose F; Okafor, Ikechukwu U; Rami, Tanya; Kumar, Gautam; Thourani, Vinod H; Jilaihawi, Hasan; Babaliaros, Vasilis; Makkar, Raj R; Yoganathan, Ajit P

    2017-10-24

    Transcatheter heart valve (THV) thrombosis has been increasingly reported. In these studies, thrombus quantification has been based on a 2-dimensional assessment of a 3-dimensional phenomenon. Postprocedural, 4-dimensional, volume-rendered CT data of patients with CoreValve, Evolut R, and SAPIEN 3 transcatheter aortic valve replacement enrolled in the RESOLVE study (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Dysfunction With Multimodality Imaging and Its Treatment with Anticoagulation) were included in this analysis. Patients on anticoagulation were excluded. SAPIEN 3 and CoreValve/Evolut R patients with and without hypoattenuated leaflet thickening were included to study differences between groups. Patients were classified as having THV thrombosis if there was any evidence of hypoattenuated leaflet thickening. Anatomic and THV deployment geometries were analyzed, and thrombus volumes were computed through manual 3-dimensional reconstruction. We aimed to identify and evaluate risk factors that contribute to THV thrombosis through the combination of retrospective clinical data analysis and in vitro imaging in the space between the native and THV leaflets (neosinus). SAPIEN 3 valves with leaflet thrombosis were on average 10% further expanded (by diameter) than those without (95.5±5.2% versus 85.4±3.9%; P <0.001). However, this relationship was not evident with the CoreValve/Evolut R. In CoreValve/Evolut Rs with thrombosis, the thrombus volume increased linearly with implant depth ( R 2 =0.7, P <0.001). This finding was not seen in the SAPIEN 3. The in vitro analysis showed that a supraannular THV deployment resulted in a nearly 7-fold decrease in stagnation zone size (velocities <0.1 m/s) when compared with an intraannular deployment. In addition, the in vitro model indicated that the size of the stagnation zone increased as cardiac output decreased. Although transcatheter aortic valve replacement thrombosis is a multifactorial process

  16. Multi-physics 3D computational study of leaflet thrombus formation following surgical and transcatheter aortic valve replacement

    NASA Astrophysics Data System (ADS)

    Vahidkhah, Koohyar; Abbasi, Mostafa; Barakat, Mohammed; Dvir, Danny; Azadani, Ali

    2017-11-01

    An increasingly recognized complication following surgical/transcatheter aortic valve replacement is thrombosis or blood clot formation on replacement valve leaflets. A predisposing factor in thrombus formation on biomaterial surfaces of a bioprosthetic heart valve is blood stasis. Longer residence time of blood provides an opportunity for platelets and agonists to accumulate to critical concentrations that leads to platelet activation and then thrombosis. In this study, we have developed a fluid-solid interaction (FSI) modeling approach, to quantify blood stasis on the leaflets of bioprosthetic aortic valves with different design operating in a patient-specific geometry. We have validated our FSI model against experimental measurements of valve opening/closing as well as in-vitro particle image velocimetry. We have also embedded in our method a model for transport of platelets and agonists (ADP, TxA2, and thrombin) and their interactions that result in platelets activation and adhesion to biomaterial bioprosthetic surfaces. We have provided quantitative evidence for the correlation between long residence of blood on bioprosthetic aortic valve leaflets and formation of high thrombogenicity risk regions on the leaflets that are characterized by accumulation of activated platelet.

  17. Effect of the Mitral Valve's Anterior Leaflet on Axisymmetry of Transmitral Vortex Ring.

    PubMed

    Falahatpisheh, Ahmad; Pahlevan, Niema M; Kheradvar, Arash

    2015-10-01

    The shape and formation of transmitral vortex ring are shown to be associated with diastolic function of the left ventricle (LV). Transmitral vortex ring is a flow feature that is observed to be non-axisymmetric in a healthy heart and its inherent asymmetry in the LV assists in efficient ejection of the blood during systole. This study is a first step towards understanding the effects of the mitral valve's anterior leaflet on transmitral flow. We experimentally study a single-leaflet model of the mitral valve to investigate the effect of the anterior leaflet on the axisymmetry of the generated vortex ring based on the three-dimensional data acquired using defocusing digital particle image velocimetry. Vortex rings form downstream of a D-shaped orifice in presence or absence of the anterior leaflet in various physiological stroke ratios. The results of the statistical analysis indicate that the formed vortex ring downstream of a D-shaped orifice is markedly non-axisymmetric, and presence of the anterior leaflet improves the ring's axisymmetry. This study suggests that the improvement of axisymmetry in presence of the anterior leaflet might be due to coupled dynamic interaction between rolling-up of the shear layer at the edges of the D-shaped orifice and the borders of the anterior leaflet. This interaction can reduce the non-uniformity in vorticity generation, which results in more axisymmetric behavior compared to the D-shaped orifice without the anterior leaflet.

  18. An inverse modeling approach for semilunar heart valve leaflet mechanics: exploitation of tissue structure.

    PubMed

    Aggarwal, Ankush; Sacks, Michael S

    2016-08-01

    Determining the biomechanical behavior of heart valve leaflet tissues in a noninvasive manner remains an important clinical goal. While advances in 3D imaging modalities have made in vivo valve geometric data available, optimal methods to exploit such information in order to obtain functional information remain to be established. Herein we present and evaluate a novel leaflet shape-based framework to estimate the biomechanical behavior of heart valves from surface deformations by exploiting tissue structure. We determined accuracy levels using an "ideal" in vitro dataset, in which the leaflet geometry, strains, mechanical behavior, and fibrous structure were known to a high level of precision. By utilizing a simplified structural model for the leaflet mechanical behavior, we were able to limit the number of parameters to be determined per leaflet to only two. This approach allowed us to dramatically reduce the computational time and easily visualize the cost function to guide the minimization process. We determined that the image resolution and the number of available imaging frames were important components in the accuracy of our framework. Furthermore, our results suggest that it is possible to detect differences in fiber structure using our framework, thus allowing an opportunity to diagnose asymptomatic valve diseases and begin treatment at their early stages. Lastly, we observed good agreement of the final resulting stress-strain response when an averaged fiber architecture was used. This suggests that population-averaged fiber structural data may be sufficient for the application of the present framework to in vivo studies, although clearly much work remains to extend the present approach to in vivo problems.

  19. Nonlinear solid finite element analysis of mitral valves with heterogeneous leaflet layers

    NASA Astrophysics Data System (ADS)

    Prot, V.; Skallerud, B.

    2009-02-01

    An incompressible transversely isotropic hyperelastic material for solid finite element analysis of a porcine mitral valve response is described. The material model implementation is checked in single element tests and compared with a membrane implementation in an out-of-plane loading test to study how the layered structures modify the stress response for a simple geometry. Three different collagen layer arrangements are used in finite element analysis of the mitral valve. When the leaflets are arranged in two layers with the collagen on the ventricular side, the stress in the fibre direction through the thickness in the central part of the anterior leaflet is homogenized and the peak stress is reduced. A simulation using membrane elements is also carried out for comparison with the solid finite element results. Compared to echocardiographic measurements, the finite element models bulge too much in the left atrium. This may be due to evidence of active muscle fibres in some parts of the anterior leaflet, whereas our constitutive modelling is based on passive material.

  20. Stress Analysis of Transcatheter Aortic Valve Leaflets Under Dynamic Loading: Effect of Reduced Tissue Thickness.

    PubMed

    Abbasi, Mostafa; Azadani, Ali N

    2017-07-01

    In order to accommodate transcatheter valves to miniaturized catheters, the leaflet thickness must be reduced to a value which is typically less than that of surgical bioprostheses. The study aim was to use finite-element simulations to determine the impact of the thickness reduction on stress and strain distribution. A 23 mm transcatheter aortic valve (TAV) was modelled based on the Edwards SAPIEN XT (Edwards Lifesciences, Irvine, CA, USA). Finite-element (FE) analysis was performed using the ABAQUS/Explicit solver. An ensemble-averaged transvalvular pressure waveform measured from in-vitro tests conducted in a pulse duplicator was applied to the leaflets. Through a parametric study, uniform TAV leaflet thickness was reduced from 0.5 to 0.18 mm. By reducing leaflet thickness, significantly higher stress values were found in the leaflet's fixed edge during systole, and in the commissures during diastole. Through dynamic FE simulations, the highest stress values were found during systole in the leaflet fixed edge. In contrast, at the peak of diastole high-stress regions were mainly observed in the commissures. The peak stress was increased by 178% and 507% within the leaflets after reducing the thickness of 0.5 mm to 0.18 mm at the peak of systole and diastole, respectively. The study results indicated that, the smaller the leaflet thickness, the higher the maximum principal stress. Increased mechanical stress on TAV leaflets may lead to accelerated tissue degeneration. By using a thinner leaflet, TAV durability may not atch with that of surgical bioprostheses.

  1. Provision of tricuspid valve leaflets by septal papillary muscles in the right ventricle of human and other mammal hearts.

    PubMed

    Jezyk, Damian; Jerzemowski, Janusz; Grzybiak, Marek

    2003-01-01

    Leaflets of the tricuspid valve are provided by tendinous cords extending from the papillary muscles. The situation is complicated with the septal muscles, which generally occur in two groups, one as constant musculus coni arteriosi and the second as other variable septal muscles. We tested whether there is a variability in the provision of the tricuspid valve in different taxonomical groups of mammals. The material examined consisted of 299 hearts of mammals (Primates, Ungulata, Carnivora, Lagomorpha, Rodentia, Marsupialia). The musculus coni arteriosi in the majority of mammals provided only the front leaflet, but among Ungulata and Rodentia it provided simultaneously the front and septal leaflet. The other septal muscles provided the front, septal and even back leaflets. The following regularity was observed: in the hearts of Primates provision of the front leaflet and the front part of the septal leaflet predominated, among Ungulata the muscles provided the middle part of the septal leaflet, but among the other mammals the rest of the septal muscles provided, significantly, the back part of the septal leaflet. Such a provision was characteristic for predators, hares, rodents and marsupials. These circumstances may allow the conclusion to be drawn that there is a taxonomical dependence in the provision of the tricuspid valve in the hearts of the mammals under examination.

  2. Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

    PubMed

    Shi, Yubing; Yeo, Tony Joon Hock; Zhao, Yong; Hwang, Ned H C

    2006-12-01

    Particle Image Velocimetry (PIV) is an important technique in studying blood flow in heart valves. Previous PIV studies of flow around prosthetic heart valves had different research concentrations, and thus never provided the physical flow field pictures in a complete heart cycle, which compromised their pertinence for a better understanding of the valvular mechanism. In this study, a digital PIV (DPIV) investigation was carried out with improved accuracy, to analyse the pulsatile flow field around the bi-leaflet mechanical heart valve (MHV) in a complete heart cycle. For this purpose a pulsatile flow test rig was constructed to provide the necessary in vitro test environment, and the flow field around a St. Jude size 29 bi-leaflet MHV and a similar MHV model were studied under a simulated physiological pressure waveform with flow rate of 5.2 l/min and pulse rate at 72 beats/min. A phase-locking method was applied to gate the dynamic process of valve leaflet motions. A special image-processing program was applied to eliminate optical distortion caused by the difference in refractive indexes between the blood analogue fluid and the test section. Results clearly showed that, due to the presence of the two leaflets, the valvular flow conduit was partitioned into three flow channels. In the opening process, flow in the two side channels was first to develop under the presence of the forward pressure gradient. The flow in the central channel was developed much later at about the mid-stage of the opening process. Forward flows in all three channels were observed at the late stage of the opening process. At the early closing process, a backward flow developed first in the central channel. Under the influence of the reverse pressure gradient, the flow in the central channel first appeared to be disturbed, which was then transformed into backward flow. The backward flow in the central channel was found to be the main driving factor for the leaflet rotation in the valve

  3. Tissue-Engineered Fibrin-Based Heart Valve with a Tubular Leaflet Design

    PubMed Central

    Weber, Miriam; Heta, Eriona; Moreira, Ricardo; Gesche, Valentine N.; Schermer, Thomas; Frese, Julia

    2014-01-01

    The general approach in heart valve tissue engineering is to mimic the shape of the native valve in the attempt to recreate the natural haemodynamics. In this article, we report the fabrication of the first tissue-engineered heart valve (TEHV) based on a tubular leaflet design, where the function of the leaflets of semilunar heart valves is performed by a simple tubular construct sutured along a circumferential line at the root and at three single points at the sinotubular junction. The tubular design is a recent development in pericardial (nonviable) bioprostheses, which has attracted interest because of the simplicity of the construction and the reliability of the implantation technique. Here we push the potential of the concept further from the fabrication and material point of view to realize the tube-in-tube valve: an autologous, living HV with remodelling and growing capability, physiological haemocompatibility, simple to construct and fast to implant. We developed two different fabrication/conditioning procedures and produced fibrin-based constructs embedding cells from the ovine umbilical cord artery according to the two different approaches. Tissue formation was confirmed by histology and immunohistology. The design of the tube-in-tube foresees the possibility of using a textile coscaffold (here demonstrated with a warp-knitted mesh) to achieve enhanced mechanical properties in vision of implantation in the aortic position. The tube-in-tube represents an attractive alternative to the conventional design of TEHVs aiming at reproducing the valvular geometry. PMID:23829551

  4. Restoration of Tricuspid Valve Mechanism at the Level of Displaced Septal and Posterior Leaflets in Ebstein's Anomaly.

    PubMed

    Im, Yu-Mi; Park, Chun Soo; Park, Jeong-Jun; Yun, Tae-Jin

    2016-03-01

    Surgical techniques currently used for the repair of Ebstein's anomaly comprise reconstruction of the tricuspid valve mechanism at the level of the true annulus with or without plication of the atrialized right ventricle. However, performing this procedure for patients with a dysmorphic anterior leaflet (i.e., insufficient leaflet tissue and decreased mobility due to tethering) may necessitate technical modifications. A retrospective review was performed of 31 patients (seven males and 24 females, median age at operation 31 years) with Ebstein's anomaly, who underwent tricuspid valve repair between March 2002 and December 2014. The original Hetzer technique (annulus to annulus approximation) was employed for six patients with a well-formed anterior leaflet. In 25 patients, the tricuspid valve mechanism was restored at the displaced septal leaflet by approximating the anterior leaflet attachment in the true annulus to the displaced septal leaflet attachment in the mid-septum. A bidirectional superior cavopulmonary anastomosis was added in 27 of 31 (87%) patients. No early or late death occurred during the median follow-up of 66 months (1-138 months). Immediate postoperative tricuspid regurgitation was trivial to mild in 22 patients, and the median preoperative, immediate postoperative, and last follow-up tricuspid regurgitation jet areas in 21 adult patients were 23.3 cm2, 10.4 cm2, and 7.0 cm2, respectively. Two patients underwent reoperation at 81 and 119 months postoperatively. Five-year freedom from severe tricuspid regurgitation or reoperation was 93.2%. Restoration of the tricuspid valve mechanism at the level of displaced septal leaflet leads to excellent long-term outcomes. The addition of the bidirectional superior cavopulmonary anastomosis has contributed to the success of this technique. © 2016 Wiley Periodicals, Inc.

  5. Biomechanical and ultrastructural comparison of cryopreservation and a novel cellular extraction of porcine aortic valve leaflets.

    PubMed

    Courtman, D W; Pereira, C A; Omar, S; Langdon, S E; Lee, J M; Wilson, G J

    1995-12-01

    Heart valve substitutes of biological origin often fail by degenerative mechanisms. Many authors have hypothesized that mechanical fatigue and structural degradation are instrumental to in vivo failure. Since the properties of the structural matrix at implantation may predetermine failure, we have examined the ultrastructure, fracture, mechanics, and uniaxial high-strain-rate viscoelastic properties of: (1) fresh, (2) cryopreserved, and (3) cellular extracted porcine aortic valve leaflets. The cellular extraction process is being developed in order to reduce immunological attack and calcification. Cryopreservation causes cellular disruption and necrotic changes throughout the tissue, whereas extraction removes all cells and lipid membranes. Both processes leave an intact collagen and elastin structural matrix and preserve the high-strain-rate viscoelastic characteristics of the fresh leaflets. Extraction does cause a 20% reduction in the fracture tension and increases tissue extensibility, with the percent strain at fracture rising to 45.3 +/- 4 (mean +/- SEM) from 31.5 +/- 3 for fresh leaflets. However, extraction does preserve matrix structure and mechanics over the physiological loading range. Glutaraldehyde fixation produces increased extensibility, increased elastic behavior, and, when applied to extracted leaflets, it causes a marked drop in fracture tension, to 50% of that for fresh leaflets. The combination of extraction and fixation may lead to early degenerative failure. The cellular extraction technique alone may be a useful alternative to glutaraldehyde fixation in preparing bioprosthetic heart valves.

  6. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    PubMed

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  7. Are anticoagulant independent mechanical valves within reach—fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models

    PubMed Central

    Siegel, Rolland

    2015-01-01

    Background Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Methods Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Results Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Conclusions Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration

  8. Mitral valve stenosis caused by abnormal pannus extension over the prosthetic ring and leaflets after Duran ring mitral annuloplasty.

    PubMed

    Yunoki, Junji; Minato, Naoki; Katayama, Yuji; Sato, Hisashi

    2009-01-01

    We treated a 61-year-old woman with mitral stenosis caused by pannus formation after Duran ring annuloplasty. Pannus overgrowth on the ring with extension onto both leaflets narrowed the mitral orifice and severely restricted the mobility of the valve leaflets. Mitral valve replacement with a St. Jude Medical mechanical heart valve prosthesis was successfully performed, and the postoperative course was uneventful. Patients undergoing Duran ring annuloplasty should be followed up with the consideration of possible mitral stenosis caused by pannus extension, as the cause for pannus formation remains unclear.

  9. Tissue-Engineered Heart Valve with a Tubular Leaflet Design for Minimally Invasive Transcatheter Implantation

    PubMed Central

    Moreira, Ricardo; Velz, Thaddaeus; Alves, Nuno; Gesche, Valentine N.; Malischewski, Axel; Schmitz-Rode, Thomas; Frese, Julia

    2015-01-01

    Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect

  10. Tissue Doppler imaging and echo-Doppler findings associated with a mitral valve stenosis with an immobile posterior valve leaflet in a bull terrier.

    PubMed

    Tidholm, A; Nicolle, A P; Carlos, C; Gouni, V; Caruso, J L; Pouchelon, J L; Chetboul, V

    2004-04-01

    A mitral valve stenosis was diagnosed in a 2-year-old female Bull Terrier by use of two-dimensional (2-D) and M-mode echocardiography, colour-flow imaging and spectral Doppler examinations. Tissue Doppler Imaging was also performed to assess the segmental radial myocardial motion. The mitral valve stenosis was characterized by a decreased mitral orifice area/left ventricle area ratio (0.14), an increased early diastolic flow velocity (E wave = 1.9 m/s), a prolonged pressure half-time (106 ms) and a decreased E-F slope (4.5 cm/s) on pulsed-wave Doppler examination. This mitral stenosis was associated with an immobile posterior leaflet, as seen on 2-D and M-mode echocardiography. Immobility of the posterior mitral leaflet is considered to be a rare finding in humans and, to our knowledge, has not been precisely documented in dogs with mitral valve stenosis.

  11. Late leaflet fracture and embolization of a Duromedics mitral prosthesis.

    PubMed

    Sudo, K; Sasagawa, N; Ide, H; Nunokawa, M; Fujiki, T; Tonari, K

    2000-08-01

    A case of leaflet fracture and embolization of a mitral prosthetic valve is described. A 54-year-old man had received mitral valve replacement with an Edwards-Duromedics 29M prosthetic valve, at 10 years ago. Emergency mitral valve replacement was performed because the patient had severe congestive left heart failure with severe acute mitral regurgitation caused by a fracture in one of the mitral valve leaflets. The leaflet, which was fractured into 2 pieces, was removed from the right common iliac artery at 3 months after valve replacement. Visual inspection revealed that the leaflet contained a midline fracture. The fracture originated within a cavitary erosion pit near the major radius of the leaflet. The patient recovered from acute renal failure, requiring hemodialysis for 80 days, and is currently without complaints. We have used a Duromedics mitral valve in 11 patients, from April 1987 to April 1988. No subsequent valve failure has occurred. The diagnosis, treatment and cause of a mechanical valve fracture are discussed.

  12. Epicardially-derived Fibroblasts Preferentially Contribute to the Parietal Leaflets of the Atrioventricular Valves in the Murine Heart

    PubMed Central

    Wessels, Andy; van den Hoff, Maurice J. B.; Adamo, Richard F.; Phelps, Aimee L.; Lockhart, Marie M.; Sauls, Kimberly; Briggs, Laura E.; Norris, Russell A.; van Wijk, Bram; Perez-Pomares, Jose M.; Dettman, Robert W.; Burch, John B. E.

    2012-01-01

    The importance of the epicardium for myocardial and valvuloseptal development has been well established; perturbation of epicardial development results in cardiac abnormalities, including thinning of the ventricular myocardial wall and malformations of the atrioventricular valvuloseptal complex. To determine the spatiotemporal contribution of epicardially derived cells to the developing fibroblast population in the heart we have used a mWt1/IRES/GFP-Cre mouse to trace the fate of EPDCs from embryonic day (ED)10 until birth. EPDCs begin to populate the compact ventricular myocardium around ED12. The migration of epicardially-derived fibroblasts toward the interface between compact and trabecular myocardium is completed around ED14. Remarkably, epicardially-derived fibroblasts do not migrate into the trabecular myocardium until after ED17. Migration of EPDCs into the atrioventricular cushion mesenchyme commences around ED12. As development progresses, the number of EPDCs increases significantly, specifically in the leaflets which derive from the lateral atrioventricular cushions. In these developing leaflets the epicardially-derived fibroblasts eventually largely replace the endocardially-derived cells. Importantly, the contribution of EPDCs to the leaflets derived from the major AV cushions is very limited. The differential contribution of EPDCs to the various leaflets of the atrioventricular valves provides a new paradigm in valve development and could lead to new insights into the pathogenesis of abnormalities that preferentially affect individual components of this region of the heart. The notion that there is a significant difference in the contribution of epicardially and endocardially derived cells to the individual leaflets of the atrioventricular valves has also important pragmatic consequences for the use of endocardial and epicardial cre-mouse models in studies of heart development. PMID:22546693

  13. Treatment of severe mitral regurgitation caused by lesions in both leaflets using multiple mitral valve plasty techniques in a small dog

    PubMed Central

    Yokoyama, Satoko; Kanemoto, Isamu; Mihara, Kippei; Ando, Takanori; Kawase, Koudai; Sahashi, Yasuaki; Iguchi, Kazuhito

    2017-01-01

    Mitral valve plasty (MVP) is preferred over mitral valve replacement (MVR) for mitral regurgitation in humans because of its favorable effect on quality of life. In small dogs, it is difficult to repair multiple lesions in both leaflets using MVP. Herein, we report a case of severe mitral regurgitation caused by multiple severe lesions in the posterior leaflet (PL) in a mixed Chihuahua. Initially, we had planned MVR with an artificial valve. However, MVP combined with artificial chordal reconstruction of both leaflets, semicircular suture annuloplasty, and valvuloplasty using a newly devised direct scallop suture for the PL was attempted in this dog. The dog recovered well and showed no adverse cardiac signs, surviving two major operations. The dog died 4 years and 10 months after the MVP due to non-cardiovascular disease. Our additional technique of using a direct scallop suture seemed useful for PL repair involving multiple scallops in a small dog. PMID:29201662

  14. Kangaroo versus porcine aortic valve tissue--valve geometry morphology, tensile strength and calcification potential.

    PubMed

    Neethling, W M; Papadimitriou, J M; Swarts, E; Hodge, A J

    2000-06-01

    Valve related factors and patient related factors are responsible for calcification of valvular bioprostheses. Recent studies showed different donor and recipient species have different influences on the total calcification rate of bioprostheses. This study was performed to evaluate and compare Kangaroo aortic valve leaflets with porcine aortic valve leaflets. Experimental design. Prospective study. Setting. Cardio-thoracic experimental research of a university department. Glutaraldehyde-fixed Kangaroo and porcine valve leaflets were evaluated in vitro according to valve geometry (internal diameter and leaflet thickness), morphology (light and electron microscopy) and tensile strength. In vivo evaluation consisted of implantation in a rat model for 8 weeks, Von Kossa stain for calcium and atomic absorption spectrophotometry for total extractable calcium content. Kangaroo valves indicated a smaller internal valve diameter as well as a thinner valve leaflet (p<0.01, ANOVA) at corresponding body weight, less proteoglycan spicules in the fibrosa, increased elasticity (p<0.05) and low calcification potential (p<0.01, confidence interval 95%). Kangaroo aortic valve leaflets have different valvular qualities compared to porcine valve tissue. Kangaroo valve leaflets are significantly superior to porcine valve leaflets as far as calcification is concerned. These results are encouraging and suggest further in vivo evaluation in a larger animal model before clinical application can be considered.

  15. Hypoplasia or Absence of Posterior Leaflet: A Rare Congenital Anomaly of The Mitral Valve in Adulthood - Case Series.

    PubMed

    Parato, Vito Maurizio; Masia, Stefano Lucio

    2018-01-01

    We present a case series of two adult patients with almost complete absence of the posterior mitral valve leaflet and who are asymptomatic or mildly symptomatic, with two different degrees of mitral regurgitation.

  16. The Impact of Fluid Inertia on In Vivo Estimation of Mitral Valve Leaflet Constitutive Properties and Mechanics.

    PubMed

    Bark, David L; Dasi, Lakshmi P

    2016-05-01

    We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstruction of markers from stereo images. To investigate the effect in vivo, the analysis is repeated on a published dataset for an ovine mitral valve (Journal of Biomechanics 42(16): 2697-2701). The membrane experiment demonstrates that the relationship between pressure and strain must be corrected with a fluid inertia term if the ratio of inertia to pressure differential approaches 1. In the mitral valve, this ratio reaches 0.7 during isovolumetric contraction for an acceleration of 6 m/s(2). Acceleration is reduced by 72% during isovolumetric relaxation. Fluid acceleration also varies along the leaflet during isovolumetric phases, resulting in spatial variations in stress. These results demonstrate that fluid inertia may be the source of the temporally and spatially varying stiffness measurements previously seen through inverse finite element analysis of in vivo data during isovolumetric phases. This study demonstrates that there is a need to account for added mass effects when analyzing in vivo constitutive relationships of heart valves.

  17. Pregnancy-induced remodeling of heart valves.

    PubMed

    Pierlot, Caitlin M; Moeller, Andrew D; Lee, J Michael; Wells, Sarah M

    2015-11-01

    Recent studies have demonstrated remodeling of aortic and mitral valves leaflets under the volume loading and cardiac expansion of pregnancy. Those valves' leaflets enlarge with altered collagen fiber architecture, content, and cross-linking and biphasic changes (decreases, then increases) in extensibility during gestation. This study extends our analyses to right-sided valves, with additional compositional measurements for all valves. Valve leaflets were harvested from nonpregnant heifers and pregnant cows. Leaflet structure was characterized by leaflet dimensions, and ECM composition was determined using standard biochemical assays. Histological studies assessed changes in cellular and ECM components. Leaflet mechanical properties were assessed using equibiaxial mechanical testing. Collagen thermal stability and cross-linking were assessed using denaturation and hydrothermal isometric tension tests. Pulmonary and tricuspid leaflet areas increased during pregnancy by 35 and 55%, respectively. Leaflet thickness increased by 20% only in the pulmonary valve and largely in the fibrosa (30% thickening). Collagen crimp length was reduced in both the tricuspid (61%) and pulmonary (42%) valves, with loss of crimped area in the pulmonary valve. Thermomechanics showed decreased collagen thermal stability with surprisingly maintained cross-link maturity. The pulmonary leaflet exhibited the biphasic change in extensibility seen in left side valves, whereas the tricuspid leaflet mechanics remained largely unchanged throughout pregnancy. The tricuspid valve exhibits a remodeling response during pregnancy that is significantly diminished from the other three valves. All valves of the heart remodel in pregnancy in a manner distinct from cardiac pathology, with much similarity valve to valve, but with interesting valve-specific responses in the aortic and tricuspid valves. Copyright © 2015 the American Physiological Society.

  18. Characterizing the Collagen Fiber Orientation in Pericardial Leaflets Under Mechanical Loading Conditions

    PubMed Central

    Alavi, S. Hamed; Ruiz, Victor; Krasieva, Tatiana; Botvinick, Elliot L.; Kheradvar, Arash

    2014-01-01

    When implanted inside the body, bioprosthetic heart valve leaflets experience a variety of cyclic mechanical stresses such as shear stress due to blood flow when the valve is open, flexural stress due to cyclic opening and closure of the valve, and tensile stress when the valve is closed. These types of stress lead to a variety of failure modes. In either a natural valve leaflet or a processed pericardial tissue leaflet, collagen fibers reinforce the tissue and provide structural integrity such that the very thin leaflet can stand enormous loads related to cyclic pressure changes. The mechanical response of the leaflet tissue greatly depends on collagen fiber concentration, characteristics, and orientation. Thus, understating the microstructure of pericardial tissue and its response to dynamic loading is crucial for the development of more durable heart valve, and computational models to predict heart valves’ behavior. In this work, we have characterized the 3D collagen fiber arrangement of bovine pericardial tissue leaflets in response to a variety of different loading conditions under Second-Harmonic Generation Microscopy. This real-time visualization method assists in better understanding of the effect of cyclic load on collagen fiber orientation in time and space. PMID:23180029

  19. Contribution of mitral valve leaflet length and septal wall thickness to outflow tract obstruction in patients with hypertrophic cardiomyopathy.

    PubMed

    Morant, Kareem; Mikami, Yoko; Nevis, Immaculate; McCarty, David; Stirrat, John; Scholl, David; Rajchl, Martin; Giannoccaro, Peter; Kolman, Louis; Heydari, Bobby; Lydell, Carmen; Howarth, Andrew; Grant, Andrew; White, James A

    2017-08-01

    We sought to examine whether elongation of the mitral valve leaflets in patients with hypertrophic cardiomyopathy (HCM) is synergistic to septal wall thickness (SWT) in the development of left ventricular outflow tract obstruction (LVOTO). HCM is a common genetic cardiac disease characterized by asymmetric septal hypertrophy and predisposition towards LVOTO. It has been reported that elongation of the mitral valve leaflets may be a primary phenotypic feature and contribute to LVOTO. However, the relative contribution of this finding versus SWT has not been studied. 152 patients (76 with HCM and 76 non-diseased age, race and BSA-matched controls) and 18 young, healthy volunteers were studied. SWT and the anterior mitral valve leaflet length (AMVLL) were measured using cine MRI. The combined contribution of these variables (SWT × AMVLL) was described as the Septal Anterior Leaflet Product (SALP). Peak LVOT pressure gradient was determined by Doppler interrogation and defined as "obstructive" if ≥ 30 mmHg. Patients with HCM were confirmed to have increased AMVLL compared with controls and volunteers (p < 0.01). Among HCM patients, both SWT and SALP were significantly higher in patients with LVOTO (N = 17) versus without. SALP showed modest improvement in predictive accuracy for LVOTO (AUC = 0.81) among the HCM population versus SWT alone (AUC = 0.77). However, in isolated patients this variable identified patients with LVOTO despite modest SWT. Elongation of the AMVLL is a primary phenotypic feature of HCM. While incremental contributions to LVOTO appear modest at a population level, specific patients may have dominant contribution to LVOTO. The combined marker of SALP allows for maintained identification of such patients despite modest increases in SWT.

  20. Hypoplasia or Absence of Posterior Leaflet: A Rare Congenital Anomaly of The Mitral Valve in Adulthood – Case Series

    PubMed Central

    Parato, Vito Maurizio; Masia, Stefano Lucio

    2018-01-01

    We present a case series of two adult patients with almost complete absence of the posterior mitral valve leaflet and who are asymptomatic or mildly symptomatic, with two different degrees of mitral regurgitation. PMID:29629259

  1. Constitutive modeling of jugular vein-derived venous valve leaflet tissues.

    PubMed

    Kaul, Nayyan; Huang, Hsiao-Ying Shadow

    2017-11-01

    Venous valve tissues, though used in vein reconstruction surgeries and bioprosthetic valves with moderate success, have not been extensively studied with respect to their structure. Their inherent anisotropic, non-linear behavior combined with severe diseases which affect veins, such as chronic venous insufficiency, warrant understanding the structure and material behavior of these tissues. Hence, before any bioprosthetic grafts may be used in place of tissues, it is of the utmost importance to understand the mechanical and structural properties of these tissues as this may lead to higher success rates for valve replacement surgeries. The longevity of the bioprosthetics may also increase if the manufactured grafts behave the same as native valves. Building on the scant information about the uniaxial and biaxial mechanical properties of jugular venous valves and wall tissues from previous studies, the current focus of our investigation lies in understanding the material behavior by establishing a phenomenological strain energy-based constitutive relation for the tissues. We used bovine veins to study the behavior of valve leaflet tissue and adjoining wall tissue (from the proximal and distal ends of the veins) under different biaxial testing protocols. We looked at the behavior of numerical partial derivatives of the strain energy to select a suitable functional form for the strain energy for wall and valve tissues. Using this strain energy descriptor, we determined the Cauchy stress and compared it with experimental results under additional sets of displacement-controlled biaxial testing protocols to find material specific model parameters by the Powell's method algorithm. Results show that whereas wall tissue strain energy can be explained using a polynomial non-linear function, the valve tissue, due to higher non-linearities, requires an exponential function. This study may provide useful information for the primary stages of bioprosthetic designs and replacement

  2. Systolic Anterior Motion of the Mitral Valve after Mitral Valve Repair

    PubMed Central

    Sternik, Leonid; Zehr, Kenton J.

    2005-01-01

    Factors predisposing patients to systolic anterior motion of the mitral valve (SAM) with left ventricular outflow tract (LVOT) obstruction after mitral valve repair are the presence of a myxomatous mitral valve with redundant leaflets, a nondilated hyperdynamic left ventricle, and a short distance between the mitral valve coaptation point and the ventricular septum after repair. From December 1999 through March 2000, we used our surgical method in 6 patients with severely myxomatous regurgitant mitral valves who were at risk of developing SAM. Leaflets were markedly redundant in all 6. Left ventricular function was hyperdynamic in 4 patients and normal in 2. Triangular or quadrangular resection of the midportion of the posterior leaflet and posterior band annuloplasty were performed. To prevent SAM and LVOT obstruction, extra, posteriorly directed, mid-posterior-leaflet secondary chordae tendineae, which would otherwise have been resected, were transferred to the underside of the middle of the mid-anterior leaflet with a small piece of associated valve as an anchoring pledget. This kept the redundant anterior leaflet edge, which extended below the coaptation point, away from the LVOT. No post-repair SAM or LVOT obstruction was observed on intraoperative or discharge echocardiography. All patients had no or trivial residual mitral regurgitation. We conclude that extra chordae tendineae, when available, can be used in mitral valve repair to tether the redundant anterior leaflet and thus prevent it from flipping into the LVOT. This will theoretically prevent SAM and LVOT obstruction in patients with risk factors for SAM. PMID:15902821

  3. Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves

    PubMed Central

    Bazan, Ovandir; Ortiz, Jayme Pinto; Vieira Junior, Francisco Ubaldo; Vieira, Reinaldo Wilson; Antunes, Nilson; Tabacow, Fabio Bittencourt Dutra; Costa, Eduardo Tavares; Petrucci Junior, Orlando

    2013-01-01

    Introduction In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. Objective To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. Methods To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. ) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. Results It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. Conclusions Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves. PMID:24598950

  4. AN INVERSE MODELING APPROACH FOR STRESS ESTIMATION IN MITRAL VALVE ANTERIOR LEAFLET VALVULOPLASTY FOR IN-VIVO VALVULAR BIOMATERIAL ASSESSMENT

    PubMed Central

    Lee, Chung-Hao; Amini, Rouzbeh; Gorman, Robert C.; Gorman, Joseph H.; Sacks, Michael S.

    2013-01-01

    Estimation of regional tissue stresses in the functioning heart valve remains an important goal in our understanding of normal valve function and in developing novel engineered tissue strategies for valvular repair and replacement. Methods to accurately estimate regional tissue stresses are thus needed for this purpose, and in particular to develop accurate, statistically informed means to validate computational models of valve function. Moreover, there exists no currently accepted method to evaluate engineered heart valve tissues and replacement heart valve biomaterials undergoing valvular stresses in blood contact. While we have utilized mitral valve anterior leaflet valvuloplasty as an experimental approach to address this limitation, robust computational techniques to estimate implant stresses are required. In the present study, we developed a novel numerical analysis approach for estimation of the in-vivo stresses of the central region of the mitral valve anterior leaflet (MVAL) delimited by a sonocrystal transducer array. The in-vivo material properties of the MVAL were simulated using an inverse FE modeling approach based on three pseudo-hyperelastic constitutive models: the neo-Hookean, exponential-type isotropic, and full collagen-fiber mapped transversely isotropic models. A series of numerical replications with varying structural configurations were developed by incorporating measured statistical variations in MVAL local preferred fiber directions and fiber splay. These model replications were then used to investigate how known variations in the valve tissue microstructure influence the estimated ROI stresses and its variation at each time point during a cardiac cycle. Simulations were also able to include estimates of the variation in tissue stresses for an individual specimen dataset over the cardiac cycle. Of the three material models, the transversely anisotropic model produced the most accurate results, with ROI averaged stresses at the fully

  5. Biaxial stress relaxation of semilunar heart valve leaflets during simulated collagen catabolism: Effects of collagenase concentration and equibiaxial strain state.

    PubMed

    Huang, Siyao; Huang, Hsiao-Ying Shadow

    2015-10-01

    Heart valve leaflet collagen turnover and remodeling are innate to physiological homeostasis; valvular interstitial cells routinely catabolize damaged collagen and affect repair. Moreover, evidence indicates that leaflets can adapt to altered physiological (e.g. pregnancy) and pathological (e.g. hypertension) mechanical load states, tuning collagen structure and composition to changes in pressure and flow. However, while valvular interstitial cell-secreted matrix metalloproteinases are considered the primary effectors of collagen catabolism, the mechanisms by which damaged collagen fibers are selectively degraded remain unclear. Growing evidence suggests that the collagen fiber strain state plays a key role, with the strain-dependent configuration of the collagen molecules either masking or presenting proteolytic sites, thereby protecting or accelerating collagen proteolysis. In this study, the effects of equibiaxial strain state on collagen catabolism were investigated in porcine aortic valve and pulmonary valve tissues. Bacterial collagenase (0.2 and 0.5 mg/mL) was utilized to simulate endogenous matrix metalloproteinases, and biaxial stress relaxation and biochemical collagen concentration served as functional and compositional measures of collagen catabolism, respectively. At a collagenase concentration of 0.5 mg/mL, increasing the equibiaxial strain imposed during stress relaxation (0%, 37.5%, and 50%) yielded significantly lower median collagen concentrations in the aortic valve (p = 0.0231) and pulmonary valve (p = 0.0183), suggesting that relatively large strain magnitudes may enhance collagen catabolism. Collagen concentration decreases were paralleled by trends of accelerated normalized stress relaxation rate with equibiaxial strain in aortic valve tissues. Collectively, these in vitro results indicate that biaxial strain state is capable of affecting the susceptibility of valvular collagens to catabolism, providing a basis for further investigation of

  6. COMPARISON OF ARTIFICIAL NEOCHORDAE AND NATIVE CHORDAL TRANSFER IN THE REPAIR OF A FLAIL POSTERIOR MITRAL LEAFLET: AN EXPERIMENTAL STUDY

    PubMed Central

    Padala, Muralidhar; Cardinau, Benedicte; Gyoneva, Lazarina I.; Thourani, Vinod H.

    2013-01-01

    BACKGROUND Surgical reconstruction of a flail posterior leaflet is a routine mitral valve repair, the techniques for which have evolved from leaflet resection to leaflet preservation. Artificial ePTFE neochordae are frequently used to stabilize the flail leaflet, and seldom translocation of the native secondary chordae of the valve to the leaflet free edge is used. In this study, we sought to investigate the efficacy of the two techniques to correct posterior leaflet prolapse and reduce mitral regurgitation, and quantify the acute post-repair leaflet kinematics. METHODS Adult porcine mitral valves (N =7) were studied in a pulsatile left heart experimental model in which isolated P2 flail was mimicked by marginal chordal transection. Baseline conditions were established in each valve under normal conditions (control), and followed by induction of isolated P2 flail by transecting the two marginal chordae on the posterior leaflet free edge (disease). The flail posterior leaflet was reconstructed using artificial neochordae (repair 1) and then native chordal translocation (repair 2). Reduction in leaflet flail, changes in mitral regurgitation fraction, leaflet coaptation length, and posterior leaflet mobility were measured using B-mode echocardiography or color doppler. RESULTS At baseline, all the valves were competent with no mitral regurgitation. After transection of the marginal chordae on the posterior leaflet, isolated P2 flail was evident with 13.7±13% regurgitation. Reconstruction with artificial neochordae eliminated leaflet flail and reduced mitral regurgitation to 3.2± 2.8%, and with chordal translocation leaflet flail was corrected and mitral regurgitation was measured at 2.3±2.6%. Using either repair techniques, leaflet coaptation and mobility of the repaired leaflets were adequate and comparable to the baseline measurements. CONCLUSIONS Comparable reduction leaflet flail and regurgitation, and restoration of physiological leaflet coaptation with the

  7. Modeling the Mitral Valve

    NASA Astrophysics Data System (ADS)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  8. Effect of the mitral valve on diastolic flow patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seo, Jung Hee; Vedula, Vijay; Mittal, Rajat, E-mail: mittal@jhu.edu

    2014-12-15

    The leaflets of the mitral valve interact with the mitral jet and significantly impact diastolic flow patterns, but the effect of mitral valve morphology and kinematics on diastolic flow and its implications for left ventricular function have not been clearly delineated. In the present study, we employ computational hemodynamic simulations to understand the effect of mitral valve leaflets on diastolic flow. A computational model of the left ventricle is constructed based on a high-resolution contrast computed-tomography scan, and a physiological inspired model of the mitral valve leaflets is synthesized from morphological and echocardiographic data. Simulations are performed with a diodemore » type valve model as well as the physiological mitral valve model in order to delineate the effect of mitral-valve leaflets on the intraventricular flow. The study suggests that a normal physiological mitral valve promotes the formation of a circulatory (or “looped”) flow pattern in the ventricle. The mitral valve leaflets also increase the strength of the apical flow, thereby enhancing apical washout and mixing of ventricular blood. The implications of these findings on ventricular function as well as ventricular flow models are discussed.« less

  9. Aberrant tendinous chords with tethering of the tricuspid leaflets: a congenital anomaly causing severe tricuspid regurgitation.

    PubMed

    Kobza, R; Kurz, D J; Oechslin, E N; Prêtre, R; Zuber, M; Vogt, P; Jenni, R

    2004-03-01

    To define the entity of tricuspid regurgitation caused by tethering of the tricuspid valve leaflets by aberrant tendinous chords. Retrospective study. Tertiary care centre (university teaching hospital). 10 patients with unexplained severe tricuspid regurgitation. The last 13 500 echocardiographic studies from our facility were reviewed to identify patients with severe unexplained tricuspid regurgitation. Tethering was defined by the presence of aberrant tendinous chords to the tricuspid valve leaflets limiting the mobility of the tricuspid leaflet and resulting in incomplete coaptation and apical displacement of the regurgitant jet origin. Aberrant tendinous chords were defined as those inserting at the clear zone of the tricuspid leaflet and not originating from the papillary muscle. Patients fulfilling the diagnostic criteria for Ebstein's anomaly were excluded. 10 patients with aberrant tendinous chords tethering one or more tricuspid valve leaflets were identified. There were short non-aberrant tendinous chords in seven patients, five of whom also had right ventricular or tricuspid annulus dilatation. Tethering of the tricuspid valve leaflets by aberrant tendinous chords can be the sole mechanism of congenital tricuspid regurgitation. It is often associated with short non-aberrant tendinous chords, which may develop secondary to right ventricular or tricuspid annulus dilatation. Awareness of tethering as a cause of tricuspid regurgitation may be important in planning reconstructive surgery.

  10. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    PubMed Central

    Kuwelker, Saatchi Mahesh; Shetty, Devi Prasad; Dalvi, Bharat

    2017-01-01

    Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR. PMID:28163430

  11. Opening and closing characteristics of the aortic valve after valve-sparing procedures using a new aortic root conduit.

    PubMed

    De Paulis, R; De Matteis, G M; Nardi, P; Scaffa, R; Buratta, M M; Chiariello, L

    2001-08-01

    The durability of aortic valve-sparing procedures is negatively affected by increased leaflet stress in the absence of normally shaped sinuses of Valsalva. We compared valve motion after remodeling procedures using a standard conduit and a specifically designed aortic root conduit. Echocardiographic studies of the aortic valve dynamics were performed in 14 patients after remodeling of the aortic root (7 standard conduits, group A; 7 new conduits, group B) and in 7 controls (group C). Opening and closing leaflet velocities and percent of slow closing leaflet displacement were measured. Root distensibility and the pressure strain of the elastic modulus were measured at all root levels. Root distensibility and the pressure strain of the elastic modulus were different in group A and B only at the sinuses (p < 0.001). Opening and closing leaflet velocities were not different among groups. Slow closing leaflet displacement was markedly more evident in group B patients (24.2%+/-1.9% versus 2.5%+/-1.9% in group A, p < 0.001) and similar to controls (22.1%+/-7.9%). The new conduit guarantees dynamic features of the aortic valve leaflets superior to those obtained with standard conduits and more similar to normal subjects.

  12. Crimping and deployment of balloon-expandable valved stents are responsible for the increase in the hydraulic conductance of leaflets.

    PubMed

    Convelbo, Channing; Guetat, Pierre; Cambillau, Michèle; Allam, Bachir; Bruneval, Patrick; Lafont, Antoine; Zegdi, Rachid

    2013-12-01

    Leaflet injury has been documented to occur during the deployment of valved stents (VSs). The pathological aspects, however, of this injury are difficult to quantify. Conversely, the hydraulic conductance of a (pericardial) membrane may be easily determined. The impact of crimping and deployment of VS on this parameter was therefore investigated. Bovine pericardial square (25 × 25 mm) patches were placed within a pressure chamber and their hydraulic conductance was determined. The influence of the pressure gradient and tissue thickness on this parameter was analysed. Six balloon-expandable VS were constructed. The hydraulic conductance of their bovine pericardial leaflets was determined before and after VS crimping and deployment in four of them. Pericardial leaflets of non-crimped VS were used as controls. Hydraulic conductance increased insignificantly with the pressure level within the chamber: from 128 ± 26.9 ml/h/m(2)/mmHg at a pressure of 50 mmHg to 232.3 ± 51.9 ml/h/m(2)/mmHg at a pressure of 250 mmHg (P = 0.117). Hydraulic conductance was not correlated to pericardial thickness, for thickness measurements ranging from 0.34 to 0.76 mm. The hydraulic conductance of VS leaflets significantly increased immediately after crimping from 45.2 ± 7.6 to 667.9.0 ± 527.2 ml/h/m(2)/mmHg (P < 0.001). This increase was still observed 24 h after VS deployment. No change in hydraulic conductance occurred in the control group. The determination of the hydraulic conductance of pericardial patches was easy to perform, reproducible and not influenced by tissue thickness. The hydraulic conductance of pericardial leaflets dramatically increased after VS crimping and deployment. This parameter might be, in the future, a useful noninvasive tool in studying leaflet trauma.

  13. Manipulation of valve composition to elucidate the role of collagen in aortic valve calcification

    PubMed Central

    2014-01-01

    Background Extracellular matrix (ECM) disarray is found in calcific aortic valvular disease (CAVD), yet much remains to be learned about the role of individual ECM components in valvular interstitial cell (VIC) function and dysfunction. Previous clinical analyses have shown that calcification is associated with decreased collagen content, while previous in vitro work has suggested that the presence of collagen attenuates the responsiveness of VICs to pro-calcific stimuli. The current study uses whole leaflet cultures to examine the contributions of endogenous collagen in regulating the phenotype and calcification of VICs. Methods A “top-down” approach was used to characterize changes in VIC phenotype in response to collagen alterations in the native 3D environment. Collagen-deficient leaflets were created via enzymatic treatment and cultured statically for six days in vitro. After culture, leaflets were harvested for analysis of DNA, proliferation, apoptosis, ECM composition, calcification, and gene/protein expression. Results In general, disruption of collagen was associated with increased expression of disease markers by VICs in whole organ leaflet culture. Compared to intact control leaflets, collagen-deficient leaflets demonstrated increased VIC proliferation and apoptosis, increased expression of disease-related markers such as alpha-smooth muscle actin, alkaline phosphatase, and osteocalcin, and an increase in calcification as evidenced by positive von Kossa staining. Conclusions These results indicate that disruption of the endogenous collagen structure in aortic valves is sufficient to stimulate pathological consequences in valve leaflet cultures, thereby highlighting the importance of collagen and the valve extracellular matrix in general in maintaining homeostasis of the valve phenotype. PMID:24581344

  14. Aberrant tendinous chords with tethering of the tricuspid leaflets: a congenital anomaly causing severe tricuspid regurgitation

    PubMed Central

    Kobza, R; Kurz, D J; Oechslin, E N; Prêtre, R; Zuber, M; Vogt, P; Jenni, R

    2004-01-01

    Objective: To define the entity of tricuspid regurgitation caused by tethering of the tricuspid valve leaflets by aberrant tendinous chords. Design: Retrospective study. Setting: Tertiary care centre (university teaching hospital). Patients: 10 patients with unexplained severe tricuspid regurgitation. Methods: The last 13 500 echocardiographic studies from our facility were reviewed to identify patients with severe unexplained tricuspid regurgitation. Tethering was defined by the presence of aberrant tendinous chords to the tricuspid valve leaflets limiting the mobility of the tricuspid leaflet and resulting in incomplete coaptation and apical displacement of the regurgitant jet origin. Aberrant tendinous chords were defined as those inserting at the clear zone of the tricuspid leaflet and not originating from the papillary muscle. Patients fulfilling the diagnostic criteria for Ebstein’s anomaly were excluded. Results: 10 patients with aberrant tendinous chords tethering one or more tricuspid valve leaflets were identified. There were short non-aberrant tendinous chords in seven patients, five of whom also had right ventricular or tricuspid annulus dilatation. Conclusions: Tethering of the tricuspid valve leaflets by aberrant tendinous chords can be the sole mechanism of congenital tricuspid regurgitation. It is often associated with short non-aberrant tendinous chords, which may develop secondary to right ventricular or tricuspid annulus dilatation. Awareness of tethering as a cause of tricuspid regurgitation may be important in planning reconstructive surgery. PMID:14966058

  15. Curved butterfly bileaflet prosthetic cardiac valve

    DOEpatents

    McQueen, David M.; Peskin, Charles S.

    1991-06-25

    An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

  16. Quantification and comparison of the mechanical properties of four human cardiac valves.

    PubMed

    Pham, Thuy; Sulejmani, Fatiesa; Shin, Erica; Wang, Di; Sun, Wei

    2017-05-01

    Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease. A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model. The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older). Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. Most research on heart valve

  17. A study of the pulsatile flow and its interaction with rectangular leaflets

    NASA Astrophysics Data System (ADS)

    Ledesma, Rene; Zenit, Roberto; Pulos, Guillermo

    2009-11-01

    To avoid the complexity and limited understanding of the 3D pulsatile flow field through heart valves, a cardiac-like flow circuit and a test channel were designed to study the behavior of bidimensional leaflets made of hyperelastic materials. We study a simple 2D arrangement to understand the basic physics of the flow-leaflet interaction. Creating a periodic pressure gradient, measurements of leaflet deflection were obtained for different flow conditions, geometries and materials. Using PIV and Phase Locking techniques, we have obtained the leaflet motion and the time-dependent flow velocity fields. The results show that two dimensionless parameters determine the performance of a simple bi-dimensional valve, in accordance with the flow conditions applied: π1=f(sw)^1/2(E/ρ)^1/2 and π2=V/(2slw), where f is the pulsation frequency, V is the stroke volume, s, w and l are the dimensions on the leaftlet and E and ρ are the elastic modulus and density of the material, respectively. Furthermore, we have identified the conditions for which the fluid stresses can be minimized. With these results we propose a new set of parameters to improve the performance of prosthetic heart valves and, in consequence, to reduce blood damage.

  18. Krox20 defines a subpopulation of cardiac neural crest cells contributing to arterial valves and bicuspid aortic valve.

    PubMed

    Odelin, Gaëlle; Faure, Emilie; Coulpier, Fanny; Di Bonito, Maria; Bajolle, Fanny; Studer, Michèle; Avierinos, Jean-François; Charnay, Patrick; Topilko, Piotr; Zaffran, Stéphane

    2018-01-03

    Although cardiac neural crest cells are required at early stages of arterial valve development, their contribution during valvular leaflet maturation remains poorly understood. Here, we show in mouse that neural crest cells from pre-otic and post-otic regions make distinct contributions to the arterial valve leaflets. Genetic fate-mapping analysis of Krox20-expressing neural crest cells shows a large contribution to the borders and the interleaflet triangles of the arterial valves. Loss of Krox20 function results in hyperplastic aortic valve and partially penetrant bicuspid aortic valve formation. Similar defects are observed in neural crest Krox20 -deficient embryos. Genetic lineage tracing in Krox20 -/- mutant mice shows that endothelial-derived cells are normal, whereas neural crest-derived cells are abnormally increased in number and misplaced in the valve leaflets. In contrast, genetic ablation of Krox20 -expressing cells is not sufficient to cause an aortic valve defect, suggesting that adjacent cells can compensate this depletion. Our findings demonstrate a crucial role for Krox20 in arterial valve development and reveal that an excess of neural crest cells may be associated with bicuspid aortic valve. © 2018. Published by The Company of Biologists Ltd.

  19. Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: role of real time three-dimensional echocardiography.

    PubMed

    Nucifora, Gaetano; Badano, Luigi P; Allocca, Giuseppe; Gianfagna, Pasquale; Proclemer, Alessandro; Cinello, Margherita; Fioretti, Paolo M

    2007-07-01

    Pacemaker leads may impair tricuspid valve coaptation and they are a well-known cause of mild tricuspid regurgitation. Occasionally, right ventricular leads worsen tricuspid regurgitation over time and patients develop late-onset symptoms of right-sided heart failure. The exact mechanism of this clinical entity is rarely identifiable by 2D-echocardiography only. This case report details a patient with severe tricuspid regurgitation secondary to immobilization of the anterior leaflet of the tricuspid valve by a permanent ventricular pacing lead. The mechanism of regurgitation was clarified by real time three-dimensional echocardiography that showed the location of the ventricular lead and its interference with the tricuspid valve.

  20. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    PubMed

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of <1. 0m2, and 1.5 mm for a BSA of >1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no

  1. Bicuspid aortic valve hemodynamics: a fluid-structure interaction study

    NASA Astrophysics Data System (ADS)

    Chandra, Santanu; Seaman, Clara; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV) is a congenital defect in which the aortic valve forms with two leaflets instead of three. While calcific aortic valve disease (CAVD) also develops in the normal tricuspid aortic valve (TAV), its progression in the BAV is more rapid. Although studies have suggested a mechano-potential root for the disease, the native BAV hemodynamics remains largely unknown. This study aimed at characterizing BAV hemodynamics and quantifying the degree of wall-shear stress (WSS) abnormality on BAV leaflets. Fluid-structure interaction models validated with particle-image velocimetry were designed to predict the flow and leaflet dynamics in idealized TAV and BAV anatomies. Valvular function was quantified in terms of the effective orifice area. The regional leaflet WSS was characterized in terms of oscillatory shear index, temporal shear magnitude and temporal shear gradient. The predictions indicate the intrinsic degree of stenosis of the BAV anatomy, reveal drastic differences in shear stress magnitude and pulsatility on BAV and TAV leaflets and confirm the side- and site-specificity of the leaflet WSS. Given the ability of abnormal fluid shear stress to trigger valvular inflammation, these results support the existence of a mechano-etiology of CAVD in the BAV.

  2. Multiphoton microscopy of ECM proteins in baboon aortic leaflet

    NASA Astrophysics Data System (ADS)

    Gonzalez, Mariacarla; Saytashev, Ilyas; Luna, Camila; Gonzalez, Brittany; Pinero, Alejandro; Perez, Manuel; Ramaswamy, Sharan; Ramella-Roman, Jessica

    2018-02-01

    The extracellular matrix (ECM) plays crucial role in defining mechanical properties of a heart valve yet the mechanobiological role of the ECM proteins - collagen and elastin - in living heart valve leaflets is still poorly understood. In this study, non-linear microscopy was used to obtain three dimensional images of collagen and elastin arrangement in aortic leaflets under combined steady flow (850 ml/min) and cyclic flexure (1 Hz) mechanical (dynamic) training. A novel bioreactor capable of mimicking the flow conditions in a living heart was used in this study and was optimized for microscopic imagery. A custom made non-linear microscope was used in this study to provide Second Harmonic Generation (SHG) imaging of collagen arrangement and two-photon imaging of elastin. Two control and three trained leaflet samples from static and dynamic tissue culture were imaged to observe protein changes in the tissue for a period of seven days. Dynamic training led to a decrease in alignment index of the protein fibers compared to the static treatment.

  3. Echocardiographic assessment of mitral valve morphology and performance after triangular resection of the prolapsing posterior leaflet for degenerative myxomatous disease.

    PubMed

    Chiappini, Bruno; Gregorini, Renato; De Remigis, Franco; Petrella, Licia; Villani, Carmine; Di Pietrantonio, Fabrizio; Pavicevic, Srdan; Mazzola, Alessandro

    2009-08-01

    The gold standard for the surgical treatment of prolapse of the posterior leaflet of the mitral valve (MV) for degenerative myxomatous disease has been represented by the quadrangular resection of the leaflet, according to the Carpentier technique. Since 2006 we performed a triangular resection of the prolapsing leaflet in 20 patients with myxomatous mitral regurgitation (MR). Seventeen patients (85%) underwent the triangular resection of P2; one patient (5%) had a triple scallops triangular resection (P1, P2, P3) and two (10%) a double scallops (P2, P3) resection. In this study, we report the immediate and mid-term clinical and echocardiographic results of a cohort of 20 patients, who underwent this technique. Thirty-day mortality was 0. Acute renal failure occurred in three patients (15%) and they resolved with conservative management. One patient (5%) required re-exploration for bleeding. At the mean follow-up of 13.1+/-4.2 months survival was 95%; one patient died of lymphoma during the follow-up time. All the cases were in New York Heart Association (NYHA) class I. Nineteen survivors underwent transthoracic echocardiography (TTE) (5), or transesophageal echocardiography (TEE) (13), performed by two skilled cardiologists. All patients showed no or trivial MV regurgitation. We believe that triangular resection of posterior MV leaflet (PMVL) provides excellent mid-term results providing the surgeon with a reliable and reproducible surgical option for myxomatous degenerative MV regurgitation.

  4. Distribution of the microelastic properties within the human anterior mitral leaflet.

    PubMed

    Jensen, Anne Skakkebaek; Baandrup, Ulrik; Hasenkam, J Michael; Kundu, Tribikram; Jørgensen, Claus Schiøtt

    2006-12-01

    Knowledge of the biomechanical properties of the mitral valve leaflets and their relation to histologic structure is of importance for understanding the leaflet movement characteristics under normal and pathologic conditions, but such knowledge is not yet available. The aim of this study was to determine biomechanical properties of the human anterior mitral leaflet on a microscopic scale. We used scanning acoustic microscopy (SAM) to examine the human anterior mitral leaflet. Sections of fixed human anterior mitral leaflet tissue were obtained from postmortem human anterior mitral leaflets (n = 5). We measured the speed of sound (nu(L)) in each histologic layer in three regions-of-interest (ROIs): these were at the annular edge, at the valve midpoint and close to the free edge. nu(L) varied in the three histologic layers (p < 0.01). It was higher in the fibrous layer (1.76 km/s) compared with the atrial layer (1.75 km/s) and ventricular layer (1.73 km/s). Also, nu(L) differed between positions along the length of the annulus-free edge line (p < 0.01), showing a decline from the annular edge (1.76 km/s) to the free edge (1.73 km/s), both as a whole and also within the atrial and the fibrous layer. These results demonstrate that the fibrous layer is stiffer than the atrial and ventricular layer and that the leaflet as a whole and within the atrial and the fibrous layer is stiffer at the annulus part in comparison with those near the free edge. (E-mail: ).

  5. An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound.

    PubMed

    Makhijani, V B; Yang, H Q; Singhal, A K; Hwang, N H

    1994-04-01

    A combined experimental-computational study was performed to investigate the flow mechanics which could cause cavitation during the squeezing and rebounding phases of valve closure in the 29 mm mitral bileaflet Edwards-Duromedics (ED) mechanical heart valve (MHV). Leaflet closing motion was measured in vitro, and input into a computational fluid mechanics software package, CFD-ACE, to compute flow velocities and pressures in the small gap space between the occluder tip and valve housing. The possibility of cavitation inception was predicted when fluid pressures dropped below the saturated vapor pressure for blood plasma. The computational analysis indicated that cavitation is more likely to be induced during valve rebound rather than the squeezing phase of valve closure in the 29 mm ED-MHV. Also, there is a higher probability of cavitation at lower values of the gap width at the point of impact between the leaflet tip and housing. These predictions of cavitation inception are not likely to be significantly influenced by the water-hammer pressure gradient that develops during valve closure.

  6. A Ruptured Mitral Valve Aneurysm as Complication of a Bicuspid Aortic Valve Endocarditis.

    PubMed

    Muscente, Francesca; Scarano, Michele; Clemente, Daniela; Pezzuoli, Franco; Parato, Vito Maurizio

    2017-01-01

    We present a case of a ruptured mitral valve (MV) aneurysm as a complication of a bicuspid aortic valve (BAV) endocarditis. It is about a young 35-year-old man, admitted to Cardiology Unit because of unexpected heart failure picture. We found a BAV endocarditis complicated by anterior MV-anterior leaflet aneurysm formation and subsequent severe MV regurgitation caused by aneurysm perforation. It was a particular and rare situation characterized by an infection of anterior mitral leaflet secondary to an infected regurgitant jet of a primary aortic infective endocarditis due to a BAV. A resulting aneurysm formation on the atrial side of the mitral anterior leaflet leads later to mitral perforation. In this article, we review the more relevant medical literature on this topic.

  7. Deformation Differences between Tricuspid and Bicuspid Aortic Valves in Vitro

    NASA Astrophysics Data System (ADS)

    Szeto, Kai; Rodriguez-Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan C.

    2011-11-01

    It has been shown in clinical studies that patients with congenital bicuspid aortic valves (CBAVs) develop degenerative calcification of the leaflets at young ages compared to patients with the normal tricuspid aortic valves (TAVs). It has been hypothesized that the asymmetrical geometry of the leaflets in CBAVs, flow shear stresses (SS), disturbed flow, and excessive strain rate levels are possible causes for the early calcification and stenosis. Central to the validation of this hypothesis is the need to quantify the differences in strain rate levels between the BAVs and TAVs. We simulate the CBAVs by surgically stitching two of the leaflets of a porcine aortic valve together. To quantify strain differences, we performed in-vitro experiments in both trileaflet and bileaflet valves by tracking the motion of small ink dots marked on each leaflet surface. We then used phase-locked stereo photogrammetry to reconstruct at each instant of time the 3D surface of the leaflets and measure the strain rates in both radial and circumferential directions during the whole cardiac cycle. Our results indicate that the total strain rate of the simulated BAVs is about 15 to 20% higher than the normal leaflets of TAVs at systole. In the BAVs' case, the fused leaflet stretches radially up to 25% higher than the reference length. The excessive stretching in both directions in the fused leaflet results in large changes in the flow patterns and associated wall SS.

  8. Flow-induced Flutter of Heart Valves: Experiments with Canonical Models

    NASA Astrophysics Data System (ADS)

    Dou, Zhongwang; Seo, Jung-Hee; Mittal, Rajat

    2017-11-01

    For the better understanding of hemodynamics associated with valvular function in health and disease, the flow-induced flutter of heart valve leaflets is studied using benchtop experiments with canonical valve models. A simple experimental model with flexible leaflets is constructed and a pulsatile pump drives the flow through the leaflets. We quantify the leaflet dynamics using digital image analysis and also characterize the dynamics of the flow around the leaflets using particle imaging velocimetry. Experiments are conducted over a wide range of flow and leaflet parameters and data curated for use as a benchmark for validation of computational fluid-structure interaction models. The authors would like to acknowledge Supported from NSF Grants IIS-1344772, CBET-1511200 and NSF XSEDE Grant TG-CTS100002.

  9. Swirling flow in bileaflet mechanical heart valve

    NASA Astrophysics Data System (ADS)

    Gataulin, Yakov A.; Khorobrov, Svyatoslav V.; Yukhnev, Andrey D.

    2018-05-01

    Bileaflet mechanical valves are most commonly used for heart valve replacement. Nowadays swirling blood flow is registered in different parts of the cardiovascular system: left ventricle, aorta, arteries and veins. In present contribution for the first time the physiological swirling flow inlet conditions are used for numerical simulation of aortic bileaflet mechanical heart valve hemodynamics. Steady 3-dimensional continuity and RANS equations are employed to describe blood motion. The Menter SST model is used to simulate turbulence effects. Boundary conditions are corresponded to systolic peak flow. The domain was discretized into hybrid tetrahedral and hexahedral mesh with an emphasis on wall boundary layer. A system of equations was solved in Ansys Fluent finite-volume package. Noticeable changes in the flow structure caused by inlet swirl are shown. The swirling flow interaction with the valve leaflets is analyzed. A central orifice jet changes its cross-section shape, which leads to redistribution of wall shear stress on the leaflets. Transvalvular pressure gradient and area-averaged leaflet wall shear stress increase. Physiological swirl intensity noticeably reduces downstream of the valve.

  10. [TECHNIQUES IN MITRAL VALVE REPAIR VIA A MINIMALLY INVASIVE APPROACH].

    PubMed

    Ito, Toshiaki

    2016-03-01

    In mitral valve repair via a minimally invasive approach, resection of the leaflet is technically demanding compared with that in the standard approach. For resection and suture repair of the posterior leaflet, premarking of incision lines is recommended for precise resection. As an alternative to resection and suture, the leaflet-folding technique is also recommended. For correction of prolapse of the anterior leaflet, neochordae placement with the loop technique is easy to perform. Premeasurement with transesophageal echocardiography or intraoperative measurement using a replica of artificial chordae is useful to determine the appropriate length of the loops. Fine-tuning of the length of neochordae is possible by adding a secondary fixation point on the leaflet if the loop is too long. If the loop is too short, a CV5 Gore-Tex suture can be passed through the loop and loosely tied several times to stack the knots, with subsequent fixation to the edge of the leaflet. Finally, skill in the mitral valve replacement technique is necessary as a back-up for surgeons who perform minimally invasive mitral valve repair.

  11. Clinical, echocardiographic, and Doppler imaging characteristics of mitral valve stenosis in two dogs.

    PubMed

    Fox, P R; Miller, M W; Liu, S K

    1992-11-15

    Mitral stenosis was diagnosed noninvasively by echocardiography and Doppler imaging in 2 Bull Terriers. Two-dimensional echocardiography revealed severe atrial and moderate left ventricular dilatation; severely reduced mitral valve opening excursion; doming of the cranial mitral valve leaflet into the left ventricle during diastole; thickened, nodular cranial mitral valve leaflets; and reduced mitral valve orifice. M-mode echocardiographic findings additionally indicated greatly diminished mitral valve E to F slope and abnormal caudal mitral valve leaflet motion. Color flow Doppler imaging revealed bright bursts of color with aliasing originating from the stenotic mitral valve orifice, extending into the left atrium during systole, and into the left atrium during diastole. Spectral Doppler recordings revealed transvalvular mitral valve gradients and prolonged pressure half-times. Necropsy performed on 1 dog revealed extremely thickened, nodular, and stiff mitral valves with short, thickened, and fused chordae tendineae. The diagnosis of mitral valve stenosis was easily facilitated with diagnostic ultrasonography.

  12. Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: a fatigue simulation study

    PubMed Central

    Martin, Caitlin; Sun, Wei

    2015-01-01

    Transcatheter aortic valve (TAV) intervention is now the standard-of-care treatment for inoperable patients and a viable alternative treatment option for high-risk patients with symptomatic aortic stenosis. While the procedure is associated with lower operative risk and shorter recovery times than traditional surgical aortic valve (SAV) replacement, TAV intervention is still not considered for lower-risk patients due in part to concerns about device durability. It is well known that bioprosthetic SAVs have limited durability, and TAVs are generally assumed to have even worse durability, yet there is little long-term data to confirm this suspicion. In this study, TAV and SAV leaflet fatigue due to cyclic loading was investigated through finite element analysis by implementing a computational soft tissue fatigue damage model to describe the behavior of the pericardial leaflets. Under identical loading conditions and with identical leaflet tissue properties, the TAV leaflets sustained higher stresses, strains, and fatigue damage compared to the SAV leaflets. The simulation results suggest that the durability of TAVs may be significantly reduced compared to SAVs to about 7.8 years. The developed computational framework may be useful in optimizing TAV design parameters to improve leaflet durability, and assessing the effects of underexpanded, elliptical, or non-uniformly expanded stent deployment on TAV durability. PMID:26294354

  13. Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics.

    PubMed

    Mao, Wenbin; Li, Kewei; Sun, Wei

    2016-12-01

    Computational modeling of heart valve dynamics incorporating both fluid dynamics and valve structural responses has been challenging. In this study, we developed a novel fully-coupled fluid-structure interaction (FSI) model using smoothed particle hydrodynamics (SPH). A previously developed nonlinear finite element (FE) model of transcatheter aortic valves (TAV) was utilized to couple with SPH to simulate valve leaflet dynamics throughout the entire cardiac cycle. Comparative simulations were performed to investigate the impact of using FE-only models vs. FSI models, as well as an isotropic vs. an anisotropic leaflet material model in TAV simulations. From the results, substantial differences in leaflet kinematics between FE-only and FSI models were observed, and the FSI model could capture the realistic leaflet dynamic deformation due to its more accurate spatial and temporal loading conditions imposed on the leaflets. The stress and the strain distributions were similar between the FE and FSI simulations. However, the peak stresses were different due to the water hammer effect induced by the fluid inertia in the FSI model during the closing phase, which led to 13-28% lower peak stresses in the FE-only model compared to that of the FSI model. The simulation results also indicated that tissue anisotropy had a minor impact on hemodynamics of the valve. However, a lower tissue stiffness in the radial direction of the leaflets could reduce the leaflet peak stress caused by the water hammer effect. It is hoped that the developed FSI models can serve as an effective tool to better assess valve dynamics and optimize next generation TAV designs.

  14. Patient-specific pediatric silicone heart valve models based on 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.

  15. Assessment of a new silicone tri-leaflet valve seamlessly assembled with blood chamber for a low-cost ventricular assist device.

    PubMed

    Hirai, S; Fukunaga, S; Sueshiro, M; Watari, M; Sueda, T; Matsuura, Y

    1998-06-01

    We have developed a practical, low-cost ventricular assist device (VAD) comprising a newly designed blood chamber with a silicone lenticular sac and two silicone tri-leaflet valves (STV), made en bloc. This new VAD is seamless, can be made cost-effectively and assembled with the blood chamber and valve as one body. This novel design should reduce the incident of thrombus formation because of the absence of a junction at the connecting ring and because of the use of flexible silicone materials which have both antithrombogenecity and biocompatibility. In in vitro hemodynamics testing, a batch of 3 consecutively manufactured VADs with STVs underwent hydrodynamic functional testing. These showed less regurgitation, a lower value of water hammer phenomenon, and a slightly greater pressure gradient across the valves than a mechanical valve (MV) [Björk-Shiley monostrut valve]. The flow and pulsatile efficiency were adequate and similar to that of a VAD with MVs. In in vitro durability and hemolysis tests, a VAD with STV functioned well for 54 days and showed similar hemolytic profiles to a VAD with MVs. In an in vivo acute experiment using an adult sheep, our device was problem-free providing sufficient output as a left ventricular assist device (LVAD). Although it will be necessary to decrease the pressure gradient across this STV in the future, our device showed efficient performance as a practical land cost-effective VAD for short term use.

  16. Development of an off bypass mitral valve repair.

    PubMed

    Morales, D L; Madigan, J D; Choudhri, A F; Williams, M R; Helman, D N; Elder, J B; Naka, Y; Oz, M C

    1999-01-01

    The Bow Tie Repair (BTR), a single edge-to-edge suture opposing the anterior and posterior leaflets of the mitral valve (MV), has led to satisfactory reduction of mitral regurgitation (MR) with few re-operations and excellent hemodynamic results. The simplicity of the repair lends itself to minimally invasive approaches. A MV grasper has been developed that will coapt both leaflets and fasten the structures with a graduated spiral screw. Eleven explanted adult human MVs were mounted in a mock circulatory loop created for simulating a variety of hemodynamic conditions. The MV grasper was used to place a screw in each valve, which was then continuously run for 300,000 to 1,000,000 cycles with a fixed transvalvular pressure gradient. At the completion of these studies, the valves were stressed to a maximal transvalvular gradient for ten minutes. In seven cases, MR was induced and subsequently repaired using the MV screw. In vivo, the MV screw was tested in nine male canines. Through a subcostal incision, the MV grasper entered the left ventricle, approximated the mitral leaflets and deployed the MV screw under direct visualization via an atriotomy. Follow-up transthoracic echocardiograms were done at postoperative week 1, 6, and 12 to identify screw migration, MV regurgitation/stenosis or clot formation. Dogs were sacrificed up to postoperative week 12 to allow gross and histologic assessment. In vitro, no MV screw detached from the valve leaflets or migrated during the durability testing period of 6.8 million cycles, including periods of stress load testing up to 350 mm Hg. The percent regurgitant flow used to assess MR statistically decreased with the placement of the screw from 72 +/- 7% to 34 +/- 17%; p = 0.0025. In vivo, seven dogs whose valves were examined within the first 48 hours revealed leaflet coaptation with an intact MV screw and no evidence of MR. Two dogs, followed for a prolonged period, had serial postoperative echocardiograms demonstrating

  17. Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads.

    PubMed

    Uehara, Kyokun; Minakata, Kenji; Watanabe, Kentaro; Sakaguchi, Hisashi; Yamazaki, Kazuhiro; Ikeda, Tadashi; Sakata, Ryuzo

    2016-07-01

    Tricuspid valve regurgitation due to pacemaker leads is a well-known complication. Although some reports have suggested that pacemaker leads should be surgically explanted, strongly adhered leads cannot always be removed. The aim of this study was to describe our tricuspid valve repair techniques with pacemaker leads left in situ. Our retrospective study investigated 6 consecutive patients who required tricuspid valve surgery for severe regurgitation induced by pacemaker leads. From the operative findings, we identified 3 patterns of tricuspid valve and pacemaker lead involvement. In 3 patients, the leads were caught in the chordae, in 2 patients, tricuspid regurgitation was caused by lead impingement on the septal leaflet, and in 3 patients, tricuspid valve leaflets had been perforated by the pacemaker leads. During surgery, all leads were left in situ after being separated from the leaflet or valvular apparatus. In addition, suture annuloplasty was performed for annular dilatation in all cases. In one patient, the lead was reaffixed to the annulus after the posterior leaflet was cut back towards the annulus, and the leaflet was then closed. There was one hospital death due to sepsis. The degree of tricuspid regurgitation was trivial in all surviving patients at discharge. During a mean follow-up of 21 months, one patient died from pneumonia 20 months after tricuspid valve repair. In patients undergoing tricuspid valve surgery due to severe tricuspid regurgitation caused by pacemaker leads, the leads can be left in situ after proper repair with annuloplasty. © The Author(s) 2016.

  18. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    PubMed

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  19. Fluid-structure interaction study of transcatheter aortic valve dynamics using smoothed particle hydrodynamics

    PubMed Central

    Mao, Wenbin; Li, Kewei; Sun, Wei

    2016-01-01

    Computational modeling of heart valve dynamics incorporating both fluid dynamics and valve structural responses has been challenging. In this study, we developed a novel fully-coupled fluid-structure interaction (FSI) model using smoothed particle hydrodynamics (SPH). A previously developed nonlinear finite element (FE) model of transcatheter aortic valves (TAV) was utilized to couple with SPH to simulate valve leaflet dynamics throughout the entire cardiac cycle. Comparative simulations were performed to investigate the impact of using FE-only models versus FSI models, as well as an isotropic versus an anisotropic leaflet material model in TAV simulations. From the results, substantial differences in leaflet kinematics between FE-only and FSI models were observed, and the FSI model could capture the realistic leaflet dynamic deformation due to its more accurate spatial and temporal loading conditions imposed on the leaflets. The stress and the strain distributions were similar between the FE and FSI simulations. However, the peak stresses were different due to the water hammer effect induced by the flow inertia in the FSI model during the closing phase, which led to 13%–28% lower peak stresses in the FE-only model compared to that of the FSI model. The simulation results also indicated that tissue anisotropy had a minor impact on hemodynamics of the valve. However, a lower tissue stiffness in the radial direction of the leaflets could reduce the leaflet peak stress caused by the water hammer effect. It is hoped that the developed FSI models can serve as an effective tool to better assess valve dynamics and optimize next generation TAV designs. PMID:27844463

  20. Sequential hydrophile and lipophile solubilization as an efficient method for decellularization of porcine aortic valve leaflets: Structure, mechanical property and biocompatibility study.

    PubMed

    Qiao, Wei-Hua; Liu, Peng; Hu, Dan; Al Shirbini, Mahmoud; Zhou, Xian-Ming; Dong, Nian-Guo

    2018-02-01

    Antigenicity of xenogeneic tissues is the major obstacle to increased use of these materials in clinical medicine. Residual xenoantigens in decellularized tissue elicit the immune response after implantation, causing graft failure. With this in mind, the potential use is proposed of three protein solubilization-based protocols for porcine aortic valve leaflets decellularization. It was demonstrated that hydrophile solubilization alone achieved incomplete decellularization; lipophile solubilization alone (LSA) completely removed all cells and two most critical xenoantigens - galactose-α(1,3)-galactose (α-Gal) and major histocompatibility complex I (MHC I) - but caused severe alterations of the structure and mechanical properties; sequential hydrophile and lipophile solubilization (SHLS) resulted in a complete removal of cells, α-Gal and MHC I, and good preservation of the structure and mechanical properties. In contrast, a previously reported method using Triton X-100, sodium deoxycholate and IGEPAL CA-630 resulted in a complete removal of all cells and MHC I, but with remaining α-Gal epitope. LSA- and SHLS-treated leaflets showed significantly reduced leucocyte activation (polymorphonuclear elastase) upon interaction with human blood in vitro. When implanted subdermally in rats for 6 weeks, LSA- or SHLS-treated leaflets were presented with more biocompatible implants and all four decellularized leaflets were highly resistant to calcification. These findings illustrate that the SHLS protocol could be considered as a promising decellularization method for the decellularization of xenogeneic tissues in tissue engineering and regenerative medicine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. The closing behavior of mechanical aortic heart valve prostheses.

    PubMed

    Lu, Po-Chien; Liu, Jia-Shing; Huang, Ren-Hong; Lo, Chi-Wen; Lai, Ho-Cheng; Hwang, Ned H C

    2004-01-01

    Mechanical artificial heart valves rely on reverse flow to close their leaflets. This mechanism creates regurgitation and water hammer effects that may form cavitations, damage blood cells, and cause thromboembolism. This study analyzes closing mechanisms of monoleaflet (Medtronic Hall 27), bileaflet (Carbo-Medics 27; St. Jude Medical 27; Duromedics 29), and trileaflet valves in a circulatory mock loop, including an aortic root with three sinuses. Downstream flow field velocity was measured via digital particle image velocimetry (DPIV). A high speed camera (PIVCAM 10-30 CCD video camera) tracked leaflet movement at 1000 frames/s. All valves open in 40-50 msec, but monoleaflet and bileaflet valves close in much less time (< 35 msec) than the trileaflet valve (>75 msec). During acceleration phase of systole, the monoleaflet forms a major and minor flow, the bileaflet has three jet flows, and the trileaflet produces a single central flow like physiologic valves. In deceleration phase, the aortic sinus vortices hinder monoleaflet and bileaflet valve closure until reverse flows and high negative transvalvular pressure push the leaflets rapidly for a hard closure. Conversely, the vortices help close the trileaflet valve more softly, probably causing less damage, lessening back flow, and providing a washing effect that may prevent thrombosis formation.

  2. JenaValve.

    PubMed

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  3. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review.

    PubMed

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm(2). Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9-54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier-Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair.

  4. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review

    PubMed Central

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R.; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm2. Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9–54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier–Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair. PMID:27148540

  5. Correlation of two-dimensional echocardiography and pathologic findings in porcine valve dysfunction.

    PubMed

    Forman, M B; Phelan, B K; Robertson, R M; Virmani, R

    1985-02-01

    Two-dimensional echocardiographic findings in porcine valve dysfunction were compared with pathologic findings in 10 patients (12 valves). Three specific echocardiographic findings were identified in patients with regurgitant lesions: prolapse, fracture and flail leaflets. Prolapse was associated pathologically with thinning of the leaflets, longitudinal tears close to the ring margin and acid mucopolysaccharide accumulation. Valve fracture was seen with and without prolapse and was accompanied pathologically by small pinpoint perforations or tears of the leaflet. A flail leaflet was seen with a linear tear of the free margin and was associated with calcific deposits. Mild degrees of fracture seen pathologically were missed on the echocardiographic study in five patients. Thickening or calcification, when present in moderate or severe amounts, was correctly identified by echocardiography. When all abnormal features were considered collectively, two-dimensional echocardiography correctly identified at least one of them in all patients. Therefore, two-dimensional echocardiography may prove useful in assessing the source of valvular regurgitation in patients with bioprosthetic valves.

  6. Evolving Techniques for Mitral Valve Reconstruction

    PubMed Central

    Galloway, Aubrey C.; Grossi, Eugene A.; Bizekis, Costas S.; Ribakove, Greg; Ursomanno, Patricia; Delianides, Julie; Baumann, F. Gregory; Spencer, Frank C.; Colvin, Stephen B.

    2002-01-01

    Objective To analyze the effectiveness of new techniques of mitral valve reconstruction (MVR) that have evolved over the last decade, such as aggressive anterior leaflet repair and minimally invasive surgery using an endoaortic balloon occluder. Summary Background Data MVR via conventional sternotomy has been an established treatment for mitral insufficiency for over 20 years, primarily for the treatment of patients with posterior leaflet prolapse. Methods Between June 1980 and June 2001, 1,195 consecutive patients had MVR with ring annuloplasty. Conventional sternotomy was used in 843 patients, minimally invasive surgery in 352 (since June 1996). Anterior leaflet repair was performed in 374 patients, with increasing use over the last 10 years. Follow-up was 100% complete (mean 4.6 years, range 0.5–20.5). Results Hospital mortality was 4.7% overall and 1.4% for isolated MVR (1.1% for minimally invasive surgery vs. 1.6% for conventional sternotomy;P = .4). Multivariate analysis showed the factors predictive of increased operative risk to be age, NYHA functional class, concomitant procedures, and previous cardiac surgery. The 5-year results for freedom from cardiac death, reoperation, and valve-related complications among the 782 patients with degenerative etiology are, respectively, as follows (P > .05 for all end points): for anterior leaflet repair, 93%, 94%, 90%; for no anterior leaflet repair, 91%, 92%, 91%; for minimally invasive surgery, 97%, 89%, 93%; and for conventional sternotomy, 93%, 94%, 90%. Conclusions These findings indicate that late results of MVR after minimally invasive surgery and after anterior leaflet repair are equivalent to those achievable with conventional sternotomy and posterior leaflet repair. These options significantly expand the range of patients suitable for mitral valve repair surgery and give further evidence to support wider use of minimally invasive techniques. PMID:12192315

  7. Mitral Valve Repair Using ePTFE Sutures for Ruptured Mitral Chordae Tendineae: A Computational Simulation Study

    PubMed Central

    Rim, Yonghoon; Laing, Susan T.; McPherson, David D.; Kim, Hyunggun

    2013-01-01

    Mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures is an established and preferred interventional method to resolve the complex pathophysiologic problems associated with chordal rupture. We developed a novel computational evaluation protocol to determine the effect of the artificial sutures on restoring mitral valve function following valve repair. A virtual mitral valve was created using three-dimensional echocardiographic data in a patient with ruptured mitral chordae tendineae. Virtual repairs were designed by adding artificial sutures between the papillary muscles and the posterior leaflet where the native chordae were ruptured. Dynamic finite element simulations were performed to evaluate pre- and post-repair mitral valve function. Abnormal posterior leaflet prolapse and mitral regurgitation was clearly demonstrated in the mitral valve with ruptured chordae. Following virtual repair to reconstruct ruptured chordae, the severity of the posterior leaflet prolapse decreased and stress concentration was markedly reduced both in the leaflet tissue and the intact native chordae. Complete leaflet coaptation was restored when four or six sutures were utilized. Computational simulations provided quantitative information of functional improvement following mitral valve repair. This novel simulation strategy may provide a powerful tool for evaluation and prediction of interventional treatment for ruptured mitral chordae tendineae. PMID:24072489

  8. On the Presence of Affine Fibril and Fiber Kinematics in the Mitral Valve Anterior Leaflet

    PubMed Central

    Lee, Chung-Hao; Zhang, Will; Liao, Jun; Carruthers, Christopher A.; Sacks, Jacob I.; Sacks, Michael S.

    2015-01-01

    In this study, we evaluated the hypothesis that the constituent fibers follow an affine deformation kinematic model for planar collagenous tissues. Results from two experimental datasets were utilized, taken at two scales (nanometer and micrometer), using mitral valve anterior leaflet (MVAL) tissues as the representative tissue. We simulated MVAL collagen fiber network as an ensemble of undulated fibers under a generalized two-dimensional deformation state, by representing the collagen fibrils based on a planar sinusoidally shaped geometric model. The proposed approach accounted for collagen fibril amplitude, crimp period, and rotation with applied macroscopic tissue-level deformation. When compared to the small angle x-ray scattering measurements, the model fit the data well, with an r2 = 0.976. This important finding suggests that, at the homogenized tissue-level scale of ∼1 mm, the collagen fiber network in the MVAL deforms according to an affine kinematics model. Moreover, with respect to understanding its function, affine kinematics suggests that the constituent fibers are largely noninteracting and deform in accordance with the bulk tissue. It also suggests that the collagen fibrils are tightly bounded and deform as a single fiber-level unit. This greatly simplifies the modeling efforts at the tissue and organ levels, because affine kinematics allows a straightforward connection between the macroscopic and local fiber strains. It also suggests that the collagen and elastin fiber networks act independently of each other, with the collagen and elastin forming long fiber networks that allow for free rotations. Such freedom of rotation can greatly facilitate the observed high degree of mechanical anisotropy in the MVAL and other heart valves, which is essential to heart valve function. These apparently novel findings support modeling efforts directed toward improving our fundamental understanding of tissue biomechanics in healthy and diseased conditions

  9. Multiple-Step Injection Molding for Fibrin-Based Tissue-Engineered Heart Valves

    PubMed Central

    Weber, Miriam; Gonzalez de Torre, Israel; Moreira, Ricardo; Frese, Julia; Oedekoven, Caroline; Alonso, Matilde; Rodriguez Cabello, Carlos J.

    2015-01-01

    Heart valves are elaborate and highly heterogeneous structures of the circulatory system. Despite the well accepted relationship between the structural and mechanical anisotropy and the optimal function of the valves, most approaches to create tissue-engineered heart valves (TEHVs) do not try to mimic this complexity and rely on one homogenous combination of cells and materials for the whole construct. The aim of this study was to establish an easy and versatile method to introduce spatial diversity into a heart valve fibrin scaffold. We developed a multiple-step injection molding process that enables the fabrication of TEHVs with heterogeneous composition (cell/scaffold material) of wall and leaflets without the need of gluing or suturing components together, with the leaflets firmly connected to the wall. The integrity of the valves and their functionality was proved by either opening/closing cycles in a bioreactor (proof of principle without cells) or with continuous stimulation over 2 weeks. We demonstrated the potential of the method by the two-step molding of the wall and the leaflets containing different cell lines. Immunohistology after stimulation confirmed tissue formation and demonstrated the localization of the different cell types. Furthermore, we showed the proof of principle fabrication of valves using different materials for wall (fibrin) and leaflets (hybrid gel of fibrin/elastin-like recombinamer) and with layered leaflets. The method is easy to implement, does not require special facilities, and can be reproduced in any tissue-engineering lab. While it has been demonstrated here with fibrin, it can easily be extended to other hydrogels. PMID:25654448

  10. Multiple-Step Injection Molding for Fibrin-Based Tissue-Engineered Heart Valves.

    PubMed

    Weber, Miriam; Gonzalez de Torre, Israel; Moreira, Ricardo; Frese, Julia; Oedekoven, Caroline; Alonso, Matilde; Rodriguez Cabello, Carlos J; Jockenhoevel, Stefan; Mela, Petra

    2015-08-01

    Heart valves are elaborate and highly heterogeneous structures of the circulatory system. Despite the well accepted relationship between the structural and mechanical anisotropy and the optimal function of the valves, most approaches to create tissue-engineered heart valves (TEHVs) do not try to mimic this complexity and rely on one homogenous combination of cells and materials for the whole construct. The aim of this study was to establish an easy and versatile method to introduce spatial diversity into a heart valve fibrin scaffold. We developed a multiple-step injection molding process that enables the fabrication of TEHVs with heterogeneous composition (cell/scaffold material) of wall and leaflets without the need of gluing or suturing components together, with the leaflets firmly connected to the wall. The integrity of the valves and their functionality was proved by either opening/closing cycles in a bioreactor (proof of principle without cells) or with continuous stimulation over 2 weeks. We demonstrated the potential of the method by the two-step molding of the wall and the leaflets containing different cell lines. Immunohistology after stimulation confirmed tissue formation and demonstrated the localization of the different cell types. Furthermore, we showed the proof of principle fabrication of valves using different materials for wall (fibrin) and leaflets (hybrid gel of fibrin/elastin-like recombinamer) and with layered leaflets. The method is easy to implement, does not require special facilities, and can be reproduced in any tissue-engineering lab. While it has been demonstrated here with fibrin, it can easily be extended to other hydrogels.

  11. Flow-Induced Mitral Leaflet Motion in Hypertrophic Cardiomyopathy

    NASA Astrophysics Data System (ADS)

    Meschini, Valentina; Mittal, Rajat; Verzicco, Roberto

    2017-11-01

    Hypertrophic cardiomyopathy (HCM) is considered the cause of sudden cardiac death in developed countries. Clinically it is found to be related to the thickening of the intra-ventricular septum combined with elongated mitral leaflets. During systole the low pressure, induced by the abnormal velocities in the narrowed aortic channel, can attract one or both the mitral leaflets causing the aortic obstruction and sometimes instantaneous death. In this paper a fluid structure interaction model for the flow in the left ventricle with a native mitral valve is employed to investigate the physio-pathology of HCM. The problem is studied using direct numerical simulations of the Navier-Stokes equations with a two-way coupled structural solver based on interaction potential approach for the structure dynamics. Simulations are performed for two different degrees of hypertrophy, and two values of pumping efficiency. The leaflets dynamics and the ventricle deformation resulting from the echocardiography of patients affected by HCM are well captured by the simulations. Moreover, the procedures of leaflets plication and septum myectomy are simulated in order to get insights into the efficiency and reliability of such surgery.

  12. Volumetric velocimetry downstream of a percutaneous heart valve

    NASA Astrophysics Data System (ADS)

    Raghav, Vrishank; Clifford, Christopher; Midha, Prem; Okafor, Ikechukwu; Thurow, Brian; Yoganathan, Ajit; Auburn University Collaboration; Georgia Institute of Technology Collaboration

    2017-11-01

    Transcatheter aortic valve replacement has emerged as a safe and effective treatment for severe, symptomatic aortic stenosis in intermediate or greater surgical risk patients. However, despite excellent short-term outcomes, improved imaging and awareness has led to the identification of leaflet thrombosis on the aortic side of the prosthesis. Upon implantation, the transcatheter heart valve (THV) becomes enclosed in the native aortic valve leaflet tissue dividing the native sinus into two regions - a smaller anatomical sinus and a neo-sinus. To understand the causes for thrombosis, plenoptic Particle Image Velocimetry (PIV) is used to investigate the pulsatile three-dimensional flow in the sinus and neo-sinus region of the THV. Experiments are conducted on both a real and a transparent THV model in a pulsatile flow loop capable of replicating physiological hemodynamics. Comparisons with planar PIV results demonstrate the feasibility of using Plenoptic PIV to study heart valve fluid dynamics. Large three-dimensional regions of low velocity magnitude and low viscous shear stress were observed near the heart valve which could increase particle residence time potentially leading to formation of clots the THV leaflet.

  13. Fast image-based mitral valve simulation from individualized geometry.

    PubMed

    Villard, Pierre-Frederic; Hammer, Peter E; Perrin, Douglas P; Del Nido, Pedro J; Howe, Robert D

    2018-04-01

    Common surgical procedures on the mitral valve of the heart include modifications to the chordae tendineae. Such interventions are used when there is extensive leaflet prolapse caused by chordae rupture or elongation. Understanding the role of individual chordae tendineae before operating could be helpful to predict whether the mitral valve will be competent at peak systole. Biomechanical modelling and simulation can achieve this goal. We present a method to semi-automatically build a computational model of a mitral valve from micro CT (computed tomography) scans: after manually picking chordae fiducial points, the leaflets are segmented and the boundary conditions as well as the loading conditions are automatically defined. Fast finite element method (FEM) simulation is carried out using Simulation Open Framework Architecture (SOFA) to reproduce leaflet closure at peak systole. We develop three metrics to evaluate simulation results: (i) point-to-surface error with the ground truth reference extracted from the CT image, (ii) coaptation surface area of the leaflets and (iii) an indication of whether the simulated closed leaflets leak. We validate our method on three explanted porcine hearts and show that our model predicts the closed valve surface with point-to-surface error of approximately 1 mm, a reasonable coaptation surface area, and absence of any leak at peak systole (maximum closed pressure). We also evaluate the sensitivity of our model to changes in various parameters (tissue elasticity, mesh accuracy, and the transformation matrix used for CT scan registration). We also measure the influence of the positions of the chordae tendineae on simulation results and show that marginal chordae have a greater influence on the final shape than intermediate chordae. The mitral valve simulation can help the surgeon understand valve behaviour and anticipate the outcome of a procedure. Copyright © 2018 John Wiley & Sons, Ltd.

  14. Automated segmentation and geometrical modeling of the tricuspid aortic valve in 3D echocardiographic images.

    PubMed

    Pouch, Alison M; Wang, Hongzhi; Takabe, Manabu; Jackson, Benjamin M; Sehgal, Chandra M; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2013-01-01

    The aortic valve has been described with variable anatomical definitions, and the consistency of 2D manual measurement of valve dimensions in medical image data has been questionable. Given the importance of image-based morphological assessment in the diagnosis and surgical treatment of aortic valve disease, there is considerable need to develop a standardized framework for 3D valve segmentation and shape representation. Towards this goal, this work integrates template-based medial modeling and multi-atlas label fusion techniques to automatically delineate and quantitatively describe aortic leaflet geometry in 3D echocardiographic (3DE) images, a challenging task that has been explored only to a limited extent. The method makes use of expert knowledge of aortic leaflet image appearance, generates segmentations with consistent topology, and establishes a shape-based coordinate system on the aortic leaflets that enables standardized automated measurements. In this study, the algorithm is evaluated on 11 3DE images of normal human aortic leaflets acquired at mid systole. The clinical relevance of the method is its ability to capture leaflet geometry in 3DE image data with minimal user interaction while producing consistent measurements of 3D aortic leaflet geometry.

  15. Dynamic behavior of prosthetic aortic tissue valves as viewed by high-speed cinematography.

    PubMed

    Rainer, W G; Christopher, R A; Sadler, T R; Hilgenberg, A D

    1979-09-01

    Using a valve testing apparatus of our own design and with a high-speed (600 to 800 frames per second) 16 mm movie camera, films were made of Hancock porcine, Carpentier-Edwards porcine, and Ionescu-Shiley bovine pericardial valves mounted in the aortic position and cycled under physiological conditions at 72 to 100 beats per minute. Fresh and explanted valves were observed using saline or 36.5% glycerol as the pumping solution. When fresh valves were studied using saline solution as the pumpint fluid, the Hancock and Carpentier-Edwards porcine valves showed high-frequency leaflet vibration, which increased in frequency with higher cycling rates. Abnormal leaflet motion was decreased when glycerol was used as the blood analogue. The Ionescu-Shiley bovine pericardial valve did not show abnormal leaflet motion under these conditions. Conclusions drawn from tissue valve testing studies that use excessively high pulsing rates and pressures (accelerated testing) and saline or water as pumping solutions cannot be transposed to predict the fate of tissue valves in a clinical setting.

  16. Recombinant apolipoprotein A-I Milano rapidly reverses aortic valve stenosis and decreases leaflet inflammation in an experimental rabbit model.

    PubMed

    Speidl, Walter S; Cimmino, Giovanni; Ibanez, Borja; Elmariah, Sammy; Hutter, Randolph; Garcia, Mario J; Fuster, Valentin; Goldman, Martin E; Badimon, Juan J

    2010-08-01

    Aortic stenosis (AS) is associated with significant morbidity and mortality. Recombinant apolipoprotein A-I Milano (rApoA-I(M)) induces atherosclerotic plaque regression. The aims of this study were to determine the effects of rApoA-I(M) on experimental aortic valve degeneration and its mechanisms of action. New Zealand White rabbits (n = 20) were fed an atherogenic diet for 9 months and then randomized to either placebo or rApoA-I(M). Echocardiography was used to assess the effect of the treatments on AS. Porcine aortic valve myofibroblasts (PAVMF) treated with oxidized low-density lipoprotein served to define the effects of rApoA-I(M) on the expression of monocyte chemoattractant protein-1 (MCP-1), nuclear factor (NF)-kappaB, and alkaline phosphatase (AP). Recombinant apolipoprotein A-I Milano increased aortic valve area (AVA) by 32% (0.25 +/- 0.05 to 0.34 +/- 0.07 cm(2), P < 0.01); whereas AVA remained unchanged in the placebo group (0.24 +/- 0.05 to 0.26 +/- 0.04 cm(2), P = 0.58). Histopathological examination of aortic valves in the rApoA-I(M) animals showed significantly less leaflet thickening, inflammation, and calcification vs. the placebo group. In vitro, rApoA-I(M) significantly inhibited MCP-1, AP, and NF-kappaB and decreased intracellular cholesterol content in PAVMF. Recombinant apolipoprotein A-I Milano treatment reverses AS in this experimental rabbit model. The beneficial effects seem to be mediated by enhanced cholesterol removal and by reduced inflammation and calcification.

  17. Severe mitral regurgitation due to mitral leaflet aneurysm diagnosed by three-dimensional transesophageal echocardiography: a case report.

    PubMed

    Konishi, Takao; Funayama, Naohiro; Yamamoto, Tadashi; Hotta, Daisuke; Kikuchi, Kenjiro; Ohori, Katsumi; Nishihara, Hiroshi; Tanaka, Shinya

    2016-11-22

    A small mitral valve aneurysm (MVA) presenting as severe mitral regurgitation (MR) is uncommon. A 47-year-old man with a history of hypertension complained of exertional chest discomfort. A transthoracic echocardiogram (TTE) revealed the presence of MR and prolapse of the posterior leaflet. A 6-mm in diameter MVA, not clearly visualized by TTE, was detected on the posterior leaflet on a three-dimensional (3D) transesophageal echocardiography (TEE). The patient underwent uncomplicated triangular resection of P2 and mitral valve annuloplasty, and was discharged from postoperative rehabilitation, 2 weeks after the operation. Histopathology of the excised leaflet showed myxomatous changes without infective vegetation or signs of rheumatic heart disease. A small, isolated MVA is a cause of severe MR, which might be overlooked and, therefore, managed belatedly. 3D TEE was helpful in imaging its morphologic details.

  18. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    PubMed Central

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  19. Design considerations and quantitative assessment for the development of percutaneous mitral valve stent.

    PubMed

    Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt

    2014-07-01

    Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral

  20. Fluid-Structure Interaction and Structural Analyses using a Comprehensive Mitral Valve Model with 3D Chordal Structure

    PubMed Central

    Toma, Milan; Einstein, Daniel R.; Bloodworth, Charles H.; Cochran, Richard P.; Yoganathan, Ajit P.; Kunzelman, Karyn S.

    2016-01-01

    Over the years, three-dimensional models of the mitral valve have generally been organized around a simplified anatomy. Leaflets have been typically modeled as membranes, tethered to discrete chordae typically modeled as one-dimensional, non-linear cables. Yet, recent, high-resolution medical images have revealed that there is no clear boundary between the chordae and the leaflets. In fact, the mitral valve has been revealed to be more of a webbed structure whose architecture is continuous with the chordae and their extensions into the leaflets. Such detailed images can serve as the basis of anatomically accurate, subject-specific models, wherein the entire valve is modeled with solid elements that more faithfully represent the chordae, the leaflets, and the transition between the two. These models have the potential to enhance our understanding of mitral valve mechanics, and to re-examine the role of the mitral valve chordae, which heretofore have been considered to be “invisible” to the fluid and to be of secondary importance to the leaflets. However, these new models also require a rethinking of modeling assumptions. In this study, we examine the conventional practice of loading the leaflets only and not the chordae in order to study the structural response of the mitral valve apparatus. Specifically, we demonstrate that fully resolved 3D models of the mitral valve require a fluid-structure interaction analysis to correctly load the valve even in the case of quasi-static mechanics. While a fluid-structure interaction mode is still more computationally expensive than a structural-only model, we also show that advances in GPU computing have made such models tractable. PMID:27342229

  1. Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis.

    PubMed

    Oda, Takeshi; Kato, Seiya; Tayama, Eiki; Fukunaga, Shuji; Akashi, Hidetoshi; Aoyagi, Shigeaki

    2009-01-01

    A Carpentier-Edwards pericardial (CEP) bioprosthesis was explanted from an 81-year-old woman due to nonstructural dysfunction 9 years after mitral valve replacement. The nonstructural dysfunction produced severe regurgitation in the mitral position. During the surgery, excessive pannus overgrowth was seen on the left ventricular side of the CEP bioprosthesis. Pannus overgrowth was prominent on one leaflet. That leaflet was stiff and shortened due to the excessive overgrowth of pannus. In this patient, the distortion of one leaflet was the main reason for transvalvular leakage of the CEP bioprosthesis in the mitral position. A new CEP bioprosthesis was implanted in the mitral position. Pathological analysis revealed fibrotic pannus with a small amount of cellular material over the leaflets of the resected CEP valve. This change was marked on the distorted leaflet.

  2. [Status of aortic valve reconstruction and Ross operation in aortic valve diseases].

    PubMed

    Sievers, Hans H

    2002-08-01

    At first glance the aortic valve is a relative simple valve mechanism connecting the left ventricle and the ascending aorta. Detailed analysis of the different components of the aortic valve including the leaflets and sinuses revealed a complex motion of each part leading to a perfect durable valve mechanism at rest and during exercise. Theoretically, the reconstruction or imitation of these structures in patients with aortic valve disease should lead to optimal results. Prerequisite is the exact knowledge of the important functional characteristics of the aortic valve. The dynamic behavior of the aortic root closely harmonizing with the leaflets not only warrants stress minimizing and valve durability, but also optimizes coronary flow, left ventricular function and aortic impedance. The newly discovered contractile capacity of the leaflets and the root components are important for tuning the dynamics. Isolated reconstruction of the aortic valve such as decalcification, commissurotomy, plication of ring or leaflets of a tricuspid aortic valve and cusp extension are seldom indicated in contrast to the reconstruction of the bicuspid insufficient valve. Proper indication and skilled techniques lead to excellent hemodynamic and clinical intermediate-term result up to 7 years after reconstruction. Latest follow-up revealed a mean aortic insufficiency of 0.7, maximal pressure gradient of 11.4 +/- 8.5 mm Hg with zero hospital or late mortality, reoperation or thromboembolic events in 22 patients. The reconstructive techniques for aortic root aneurysm and/or type A dissection according to David or Yacoub have become routine procedures in the last 10 years. The hemodynamic and clinical results are excellent with low reoperation rate and very low risk of thromboembolism. Generally, a maximal diameter of the root of 5 cm is indicative for performing the operation. In patients with Marfan's syndrome the reconstruction should be advanced even with smaller diameters especially

  3. Transcatheter aortic valve implantation using anatomically oriented, marrow stromal cell-based, stented, tissue-engineered heart valves: technical considerations and implications for translational cell-based heart valve concepts.

    PubMed

    Emmert, Maximilian Y; Weber, Benedikt; Behr, Luc; Sammut, Sebastien; Frauenfelder, Thomas; Wolint, Petra; Scherman, Jacques; Bettex, Dominique; Grünenfelder, Jürg; Falk, Volkmar; Hoerstrup, Simon P

    2014-01-01

    While transcatheter aortic valve implantation (TAVI) has rapidly evolved for the treatment of aortic valve disease, the currently used bioprostheses are prone to continuous calcific degeneration. Thus, autologous, cell-based, living, tissue-engineered heart valves (TEHVs) with regeneration potential have been suggested to overcome these limitations. We investigate the technical feasibility of combining the concept of TEHV with transapical implantation technology using a state-of-the-art transcatheter delivery system facilitating the exact anatomical position in the systemic circulation. Trileaflet TEHVs fabricated from biodegradable synthetic scaffolds were sewn onto self-expanding Nitinol stents seeded with autologous marrow stromal cells, crimped and transapically delivered into the orthotopic aortic valve position of adult sheep (n = 4) using the JenaValve transapical TAVI System (JenaValve, Munich, Germany). Delivery, positioning and functionality were assessed by angiography and echocardiography before the TEHV underwent post-mortem gross examination. For three-dimensional reconstruction of the stent position of the anatomically oriented system, a computed tomography analysis was performed post-mortem. Anatomically oriented, transapical delivery of marrow stromal cell-based TEHV into the orthotopic aortic valve position was successful in all animals (n = 4), with a duration from cell harvest to TEHV implantation of 101 ± 6 min. Fluoroscopy and echocardiography displayed sufficient positioning, thereby entirely excluding the native leaflets. There were no signs of coronary obstruction. All TEHV tolerated the loading pressure of the systemic circulation and no acute ruptures occurred. Animals displayed intact and mobile leaflets with an adequate functionality. The mean transvalvular gradient was 7.8 ± 0.9 mmHg, and the mean effective orifice area was 1.73 ± 0.02 cm(2). Paravalvular leakage was present in two animals, and central aortic regurgitation due to a

  4. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.

    PubMed

    Khalique, Omar K; Hahn, Rebecca T; Gada, Hemal; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Kalesan, Bindu; Forster, Molly; Williams, Mathew B; Leon, Martin B; Einstein, Andrew J; Pulerwitz, Todd C; Pearson, Gregory D N; Kodali, Susheel K

    2014-08-01

    This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) immediately after transcatheter aortic valve replacement (TAVR). The impact of AVC in different locations within the aortic valve complex is incompletely understood. This study analyzed 150 patients with severe, symptomatic aortic stenosis who underwent TAVR. Total AVC volume scores were calculated from contrast-enhanced multidetector row computed tomography imaging. AVC was divided by leaflet sector and region (Leaflet, Annulus, left ventricular outflow tract [LVOT]), and a combination of LVOT and Annulus (AnnulusLVOT). Asymmetry was assessed. Receiver-operating characteristic analysis was performed with greater than or equal to mild PVR and PD as classification variables. Logistic regression was performed. Quantity of and asymmetry of AVC for all regions of the aortic valve complex predicted greater than or equal to mild PVR by receiver-operating characteristic analysis (area under the curve = 0.635 to 0.689), except Leaflet asymmetry. Receiver-operating characteristic analysis for PD was significant for quantity and asymmetry of AVC in all regions, with higher area under the curve values than for PVR (area under the curve = 0.648 to 0.741). On multivariable analysis, Leaflet and AnnulusLVOT calcification were independent predictors of both PVR and PD regardless of multidetector row computed tomography area cover index. Quantity and asymmetry of AVC in all regions of the aortic valve complex predict greater than or equal to mild PVR and performance of PD, with the exception of Leaflet asymmetry. Quantity of AnnulusLVOT and Leaflet calcification independently predict PVR and PD when taking into account multidetector row computed tomography area cover index. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  6. Fluid mechanics of artificial heart valves.

    PubMed

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  7. Improved mitral valve coaptation and reduced mitral valve annular size after percutaneous mitral valve repair (PMVR) using the MitraClip system.

    PubMed

    Patzelt, Johannes; Zhang, Yingying; Magunia, Harry; Ulrich, Miriam; Jorbenadze, Rezo; Droppa, Michal; Zhang, Wenzhong; Lausberg, Henning; Walker, Tobias; Rosenberger, Peter; Seizer, Peter; Gawaz, Meinrad; Langer, Harald F

    2017-08-01

    Improved mitral valve leaflet coaptation with consecutive reduction of mitral regurgitation (MR) is a central goal of percutaneous mitral valve repair (PMVR) with the MitraClip® system. As influences of PMVR on mitral valve geometry have been suggested before, we examined the effect of the procedure on mitral annular size in relation to procedural outcome. Geometry of the mitral valve annulus was evaluated in 183 patients undergoing PMVR using echocardiography before and after the procedure and at follow-up. Mitral valve annular anterior-posterior (ap) diameter decreased from 34.0 ± 4.3 to 31.3 ± 4.9 mm (P < 0.001), and medio-lateral (ml) diameter from 33.2 ± 4.8 to 32.4 ± 4.9 mm (P < 0.001). Accordingly, we observed an increase in MV leaflet coaptation after PMVR. The reduction of mitral valve ap diameter showed a significant inverse correlation with residual MR. Importantly, the reduction of mitral valve ap diameter persisted at follow-up (31.3 ± 4.9 mm post PMVR, 28.4 ± 5.3 mm at follow-up). This study demonstrates mechanical approximation of both mitral valve annulus edges with improved mitral valve annular coaptation by PMVR using the MitraClip® system, which correlates with residual MR in patients with MR. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  8. Real-time 3D visualization of cellular rearrangements during cardiac valve formation

    PubMed Central

    Pestel, Jenny; Ramadass, Radhan; Gauvrit, Sebastien; Helker, Christian; Herzog, Wiebke

    2016-01-01

    During cardiac valve development, the single-layered endocardial sheet at the atrioventricular canal (AVC) is remodeled into multilayered immature valve leaflets. Most of our knowledge about this process comes from examining fixed samples that do not allow a real-time appreciation of the intricacies of valve formation. Here, we exploit non-invasive in vivo imaging techniques to identify the dynamic cell behaviors that lead to the formation of the immature valve leaflets. We find that in zebrafish, the valve leaflets consist of two sets of endocardial cells at the luminal and abluminal side, which we refer to as luminal cells (LCs) and abluminal cells (ALCs), respectively. By analyzing cellular rearrangements during valve formation, we observed that the LCs and ALCs originate from the atrium and ventricle, respectively. Furthermore, we utilized Wnt/β-catenin and Notch signaling reporter lines to distinguish between the LCs and ALCs, and also found that cardiac contractility and/or blood flow is necessary for the endocardial expression of these signaling reporters. Thus, our 3D analyses of cardiac valve formation in zebrafish provide fundamental insights into the cellular rearrangements underlying this process. PMID:27302398

  9. Real-time 3D visualization of cellular rearrangements during cardiac valve formation.

    PubMed

    Pestel, Jenny; Ramadass, Radhan; Gauvrit, Sebastien; Helker, Christian; Herzog, Wiebke; Stainier, Didier Y R

    2016-06-15

    During cardiac valve development, the single-layered endocardial sheet at the atrioventricular canal (AVC) is remodeled into multilayered immature valve leaflets. Most of our knowledge about this process comes from examining fixed samples that do not allow a real-time appreciation of the intricacies of valve formation. Here, we exploit non-invasive in vivo imaging techniques to identify the dynamic cell behaviors that lead to the formation of the immature valve leaflets. We find that in zebrafish, the valve leaflets consist of two sets of endocardial cells at the luminal and abluminal side, which we refer to as luminal cells (LCs) and abluminal cells (ALCs), respectively. By analyzing cellular rearrangements during valve formation, we observed that the LCs and ALCs originate from the atrium and ventricle, respectively. Furthermore, we utilized Wnt/β-catenin and Notch signaling reporter lines to distinguish between the LCs and ALCs, and also found that cardiac contractility and/or blood flow is necessary for the endocardial expression of these signaling reporters. Thus, our 3D analyses of cardiac valve formation in zebrafish provide fundamental insights into the cellular rearrangements underlying this process. © 2016. Published by The Company of Biologists Ltd.

  10. Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.

    PubMed

    Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas

    2017-06-01

    Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.

  11. FLUID-STRUCTURE INTERACTION MODELS OF THE MITRAL VALVE: FUNCTION IN NORMAL AND PATHOLOGIC STATES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunzelman, K. S.; Einstein, Daniel R.; Cochran, R. P.

    2007-08-29

    Successful mitral valve repair is dependent upon a full understanding of normal and abnormal mitral valve anatomy and function. Computational analysis is one such method that can be applied to simulate mitral valve function in order to analyze the roles of individual components, and evaluate proposed surgical repair. We developed the first three-dimensional, finite element (FE) computer model of the mitral valve including leaflets and chordae tendineae, however, one critical aspect that has been missing until the last few years was the evaluation of fluid flow, as coupled to the function of the mitral valve structure. We present here ourmore » latest results for normal function and specific pathologic changes using a fluid-structure interaction (FSI) model. Normal valve function was first assessed, followed by pathologic material changes in collagen fiber volume fraction, fiber stiffness, fiber splay, and isotropic stiffness. Leaflet and chordal stress and strain, and papillary muscle force was determined. In addition, transmitral flow, time to leaflet closure, and heart valve sound were assessed. Model predictions in the normal state agreed well with a wide range of available in-vivo and in-vitro data. Further, pathologic material changes that preserved the anisotropy of the valve leaflets were found to preserve valve function. By contrast, material changes that altered the anisotropy of the valve were found to profoundly alter valve function. The addition of blood flow and an experimentally driven microstructural description of mitral tissue represent significant advances in computational studies of the mitral valve, which allow further insight to be gained. This work is another building block in the foundation of a computational framework to aid in the refinement and development of a truly noninvasive diagnostic evaluation of the mitral valve. Ultimately, it represents the basis for simulation of surgical repair of pathologic valves in a clinical and

  12. Annulus fibrosus of the mitral valve: reality or myth.

    PubMed

    Berdajs, Denis; Zünd, Gregor; Camenisch, Colette; Schurr, Ulrich; Turina, Marko I; Genoni, Michele

    2007-01-01

    Surgical repair of the mitral valve is in most cases limited to the posterior leaflet of the mitral valve and to the annulus fibrosus. The term annulus fibrosus is still used in anatomical and clinical terminology and is described as a cord like structure providing the attachment of the mitral vale. However, to date no evidence exists of a ring-or cord-like structure at this area. Herein, we describe the attachment of the mitral valve by using the macroscopical and microscopical techniques. The ventricular attachment of the posterior mitral valve leaflet was investigated in 10 human hearts. In dry dissected specimens, the intraventricular illumination was used to identify the attachment of the mitral valve to the left ventricular muscle. Using the histological techniques, we verified the position of the annulus fibrosus. The attachment of the posterior mitral valve leaflet is a band-like structure positioned between the left ventricular muscle and the left atrium. This fibrous band illustrates the morphological attachment of the mitral valve and, as thus, was interpreted as the annulus fibrosus of the mitral valve. Based on our data, no ring-like structure was found corresponding to the anatomical description of the annulus fibrosus, instead the band-like fibrous tissue was identified positioned between the mitral valve and the left ventricle. Histologicaly, we detected that this structure is part of the greater structural system that is directly connected to the membranous septum, to the left and right fibrous trigone and the attachment aortic root to the left ventricular muscle.

  13. Fluid-structure interaction and structural analyses using a comprehensive mitral valve model with 3D chordal structure.

    PubMed

    Toma, Milan; Einstein, Daniel R; Bloodworth, Charles H; Cochran, Richard P; Yoganathan, Ajit P; Kunzelman, Karyn S

    2017-04-01

    Over the years, three-dimensional models of the mitral valve have generally been organized around a simplified anatomy. Leaflets have been typically modeled as membranes, tethered to discrete chordae typically modeled as one-dimensional, non-linear cables. Yet, recent, high-resolution medical images have revealed that there is no clear boundary between the chordae and the leaflets. In fact, the mitral valve has been revealed to be more of a webbed structure whose architecture is continuous with the chordae and their extensions into the leaflets. Such detailed images can serve as the basis of anatomically accurate, subject-specific models, wherein the entire valve is modeled with solid elements that more faithfully represent the chordae, the leaflets, and the transition between the two. These models have the potential to enhance our understanding of mitral valve mechanics and to re-examine the role of the mitral valve chordae, which heretofore have been considered to be 'invisible' to the fluid and to be of secondary importance to the leaflets. However, these new models also require a rethinking of modeling assumptions. In this study, we examine the conventional practice of loading the leaflets only and not the chordae in order to study the structural response of the mitral valve apparatus. Specifically, we demonstrate that fully resolved 3D models of the mitral valve require a fluid-structure interaction analysis to correctly load the valve even in the case of quasi-static mechanics. While a fluid-structure interaction mode is still more computationally expensive than a structural-only model, we also show that advances in GPU computing have made such models tractable. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Analysis of hydrodynamic losses for various types of aortic valves

    NASA Astrophysics Data System (ADS)

    Starobin, I. M.; Lupachev, S. P.; Dolgopolov, R. V.; Zaiko, V. M.; Kas'yanov, V. A.; Mungalov, D. D.; Morov, G. V.

    1985-05-01

    The creation of an automated computer-controlled hydraulic stand made it possible to measure the main hydrodynamic parameters of the flow through the investigated HVP and to determine the coefficients of Eq. (2) of fluid flow in the test chamber of the stand. The coefficients found can serve as a criterion of a comparative assessment of the hydrodynamics of HVPs. An analysis of the coefficients showed that the main contribution to pressure losses across ball and disc valves is made by viscous and convective effects. An analysis of inertial losses confirmed the presence of oscillations of the ball closing elements of the AKCh-3-06 valve around the props of the stroke limiters and made it possible to assess them quantitatively. For leaflet valves the contribution of inertial losses to the total pressure losses is more considerable than in the case of disc and ball valves both in the regime of an increase of power of the output and in the regime of a constant power. The mechanical properties of the material of leaflet valves have an effect on the hydrodynamic characteristics. The advantage of the investigated leaflet valves consists not only in that they have smaller total hydraulic losses compared with the other valves, but also in that they provide a high amplitude of pulsations of the blood stream in the case of insufficient contractility of the heart.

  15. Partial hammock valve: surgical repair in adulthood.

    PubMed

    Aramendi, José I; Rodríguez, Miguel A; Voces, Roberto; Pérez, Pedro; Rodrigo, David

    2006-09-01

    We describe a forme frustrée of hammock valve involving only the posterior mitral leaflet. Three adult patients were referred to surgery with the diagnosis of severe mitral regurgitation due to fibrosis of the posterior mitral leaflet. The final diagnosis was done intraoperatively. In all of them the posterior leaflet was attached to some accessory papillary muscles arranged en palisade, with three to four fused muscle heads producing restrictive leaflet motion in systole. Repair consisted in division of the papillary muscles, patch augmentation, and ring annuloplasty. This previously unreported lesion is congenital but manifests itself in adulthood.

  16. Iatrogenic Aortic Valve Perforation after Ventricular Septal Defect Repair

    PubMed Central

    Ren, Chonglei; Wang, Mingyan; Wang, Yao; Gao, Changqing

    2017-01-01

    Iatrogenic aortic valve (AV) perforation during non-aortic cardiac operations is a rare complication. The suture-related inadvertent injury to an AV leaflet can produce leaflet perforation with aortic regurgitation after ventricular septal defect repair (VSDR). We report three consecutive patients who had iatrogenic aortic leaflet perforation during VSDR in other hospitals and referred to our hospital for reoperation. In all three cases, the perforated AV leaflets were preserved and repaired by autologous pericardial patch or direct local closure. PMID:29057770

  17. Fluid-structure interaction analysis of the flow through a stenotic aortic valve

    NASA Astrophysics Data System (ADS)

    Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes

    2009-11-01

    In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.

  18. The challenge of valve-in-valve procedures in degenerated Mitroflow bioprostheses and the advantage of using the JenaValve transcatheter heart valve.

    PubMed

    Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik

    2014-12-01

    Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.

  19. Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure.

    PubMed

    D'Amore, Antonio; Luketich, Samuel K; Raffa, Giuseppe M; Olia, Salim; Menallo, Giorgio; Mazzola, Antonino; D'Accardi, Flavio; Grunberg, Tamir; Gu, Xinzhu; Pilato, Michele; Kameneva, Marina V; Badhwar, Vinay; Wagner, William R

    2018-01-01

    Valvular heart disease is currently treated with mechanical valves, which benefit from longevity, but are burdened by chronic anticoagulation therapy, or with bioprosthetic valves, which have reduced thromboembolic risk, but limited durability. Tissue engineered heart valves have been proposed to resolve these issues by implanting a scaffold that is replaced by endogenous growth, leaving autologous, functional leaflets that would putatively eliminate the need for anticoagulation and avoid calcification. Despite the diversity in fabrication strategies and encouraging results in large animal models, control over engineered valve structure-function remains at best partial. This study aimed to overcome these limitations by introducing double component deposition (DCD), an electrodeposition technique that employs multi-phase electrodes to dictate valve macro and microstructure and resultant function. Results in this report demonstrate the capacity of the DCD method to simultaneously control scaffold macro-scale morphology, mechanics and microstructure while producing fully assembled stent-less multi-leaflet valves composed of microscopic fibers. DCD engineered valve characterization included: leaflet thickness, biaxial properties, bending properties, and quantitative structural analysis of multi-photon and scanning electron micrographs. Quasi-static ex-vivo valve coaptation testing and dynamic organ level functional assessment in a pressure pulse duplicating device demonstrated appropriate acute valve functionality. Copyright © 2017. Published by Elsevier Ltd.

  20. Fixation and mounting of porcine aortic valves for use in mock circuits.

    PubMed

    Schlöglhofer, Thomas; Aigner, Philipp; Stoiber, Martin; Schima, Heinrich

    2013-10-01

    Investigations of the circulatory system in vitro use mock circuits that require valves to mimic the cardiac situation. Whereas mechanical valves increase water hammer effects due to inherent stiffness and do not allow the use of pressure lines or catheters, bioprosthetic valves are expensive and of limited durability in test fluids. Therefore, we developed a cheap, fast, alternative method to mount valves obtained from the slaughterhouse in mock circuits. Porcine aortic roots were obtained from the abattoir and used either in native condition or after fixation. Fixation was performed at a constant retrograde pressure to ensure closed valve position. Fixation time was 4 h in a 0.5%-glutaraldehyde phosphate buffer. The fixed valves were molded into a modular mock circulation connector using a fast curing silicone. Valve functionality was evaluated in a pulsatile setting (cardiac output = 4.7 l/min, heart rate = 80 beats/min) and compared before and after fixation. Leaflet motion was recorded with a high-speed camera and valve insufficiency was quantified by leakage flow under steady pressure application (80 mmHg). Under physiological conditions the aortic valves showed almost equal leaflet motion in native and fixed conditions. However, the leaflets of the native valves showed lower stiffness and more fluttering during systole than the fixed specimens. Under retrograde pressure, fresh and fixed valves showed small leakage flows of <30 ml/min. The new mounting and fixation procedure is a fast method to fabricate low cost biologic valves for the use in mock circuits.

  1. Mid-term function and remodeling potential of tissue engineered tricuspid valve: Histology and biomechanics.

    PubMed

    Ropcke, Diana M; Rasmussen, Jonas; Ilkjær, Christine; Skov, Søren N; Tjørnild, Marcell J; Baandrup, Ulrik T; Christian Danielsen, Carl; Hjortdal, Vibeke E; Nielsen, Sten L

    2018-04-11

    Tricuspid valve reconstruction using a small intestinal submucosal porcine extracellular matrix (ECM) tube graft is hypothesized to be durable for six months and show signs of recellularization and growth potential. The purpose was to histologically and biomechanically test ECM valves before and after six months of implantation in pigs for comparison with native valves. Ten 60 kg pigs were included, which survived tricuspid valve tube graft insertion. Anterior and septal tricuspid leaflets were explanted from all animals surviving more than one month and examined histologically (n = 9). Endothelialization, collagen content, mineralization, neovascularization, burst strength and tensile strength were determined for native valves (n = 5), ECM before implantation (n = 5), and ECM after six months (n = 5). Collagen density was significantly larger in ECM at implantation (baseline) compared to native leaflet tissue (0.3 ± 0.02 mg/mm 3 vs. 0.1 ± 0.03 mg/mm 3 , p < .0001), but collagen density decreased and reached native leaflet collagen content, six months after ECM implantation (native vs. ECM valve at six months: 0.1 ± 0.03 mg/mm 3 vs. 0.2 ± 0.05 mg/mm 3 , p = .8). Histologically, ECM valves showed endothelialization, host cell infiltration and structural collagen organization together with elastin generation after six months, indicating tissue remodeling and -engineering together with gradual development of a close-to-native leaflet structure without foreign body response. ECM tricuspid tube grafts were stronger than native leaflet tissue. Histologically, the acellular ECM tube grafts showed evidence of constructive tissue remodeling with endothelialization and connective tissue organization. These findings support the concept of tissue engineering and recellularization, which are prerequisites for growth. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Vortex dynamics in Patient-Specific Stenotic Tricuspid and Bicuspid Aortic Valves pre- and post- Trans-catheter Aortic Valve Replacement

    NASA Astrophysics Data System (ADS)

    Hatoum, Hoda; Dasi, Lakshmi Prasad

    2017-11-01

    Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.

  3. A Quantitative Study of Simulated Bicuspid Aortic Valves

    NASA Astrophysics Data System (ADS)

    Szeto, Kai; Nguyen, Tran; Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan

    2010-11-01

    Previous studies have shown that congentially bicuspid aortic valves develop degenerative diseases earlier than the standard trileaflet, but the causes are not well understood. It has been hypothesized that the asymmetrical flow patterns and turbulence found in the bileaflet valves together with abnormally high levels of strain may result in an early thickening and eventually calcification and stenosis. Central to this hypothesis is the need for a precise quantification of the differences in the strain rate levels between bileaflets and trileaflet valves. We present here some in-vitro dynamic measurements of the spatial variation of the strain rate in pig aortic vales conducted in a left ventricular heart flow simulator device. We measure the strain rate of each leaflet during the whole cardiac cycle using phase-locked stereoscopic three-dimensional image surface reconstruction techniques. The bicuspid case is simulated by surgically stitching two of the leaflets in a normal valve.

  4. Malformation of the canine mitral valve complex.

    PubMed

    Litu, S K; Tilley, L P

    1975-09-15

    Twenty-nine dogs, including 13 Great Danes and 5 German Shepherd Dogs and averaging 7.3 months age, were diagnosed clinically and radiographically as having mitral regurgitation. Alterations of the mitral valve complex included enlarged anulus; short thick leaflets, with an occasional cleft; short and stout or long and thin chordae tendineae; upward malposition of atrophic or hypertrophic papillary muscles; insertion of one papillary muscle directly into one or both leaflets; and diffuse endocardial fibrosis, occasionally with jet lesions in te left atrium. Other cardiac anomalies included dysplasia of the tricuspid valve (5 dogs), patent ductus afteriosus (2 dogs), aortic stenosis (2 dogs), and ventricular septal defect (1 dog).

  5. Occluder closing behavior: a key factor in mechanical heart valve cavitation.

    PubMed

    Wu, Z J; Wang, Y; Hwang, N H

    1994-04-01

    A laser sweeping technique developed in this laboratory was found to be capable of monitoring the leaflet closing motion with microsecond precision. The leaflet closing velocity was measured inside the last three degrees before impact. Mechanical heart valve (MHV) leaflets were observed to close with a three-phase motion; the approaching phase, the decelerating phase, and the rebound phase, all of which take place within one to two milliseconds. The leaflet closing behavior depends mainly on the leaflet design and the hinge mechanism. Bileaflet and monoleaflet types of mechanical heart valves were tested in the mitral position in a physiologic mock circulatory flow loop, which incorporated a computer-controlled magnetic drive and an adjustable afterload system. The test loop was tuned to produce physiologic ventricular and aortic pressure wave forms at 70-120 beats/min, with the maximum ventricular dp/dt varying between 1500-5600 mmHg/sec. The experiments were conducted by controlling the cardiac output at a constant level between 2.0-9.0 liters/min. The measured time-displacement curve of each tested MHV leaflet and its geometry were taken as the input for computation of the squeeze flow field in the narrow gap space between the approaching leaflet and the valve housing. The results indicated rapid build-up of both the pressure and velocity in the gap field within microsecs before the impact. The pressure build-up in the gap space is apparently responsible for the leaflet deceleration before the impact. When the concurrent water hammer pressure reduction at closure was combined with the high energy squeeze jet ejected from the gap space, there were strong indications of the environment which favors micro cavitation inceptions in certain types of MHV.

  6. Mechanisms of valve competency after mitral valve annuloplasty for ischaemic mitral regurgitation using the Geoform ring: insights from three-dimensional echocardiography.

    PubMed

    Armen, Todd A; Vandse, Rashmi; Crestanello, Juan A; Raman, Subha V; Bickle, Katherine M; Nathan, Nadia S

    2009-01-01

    Left ventricular remodelling leads to functional mitral regurgitation resulting from annular dilatation, leaflet tethering, tenting, and decreased leaflet coaptation. Mitral valve annuloplasty restores valve competency, improving the patient's functional status and ventricular function. This study was designed to evaluate the mechanisms underlying mitral valve competency after the implantation of a Geoform annuloplasty ring using three-dimensional (3D) echocardiography. Seven patients (mean age of 65 years) with ischaemic mitral regurgitation underwent mitral valve annuloplasty with the Geoform ring and coronary artery bypass surgery. Pre- and post-operative 3D echocardiograms were performed. Following mitral annuloplasty, mitral regurgitation decreased from 3.4+/-0.2 to 0.9+/-0.3 (P-value<0.0001), mitral valve tenting volume from 13+/-1.7 to 3.2+/-0.3 mL (P-value<0.001), annulus area from 12.6+/-1.0 to 3.3+/-0.2 cm2 (P-value<0.0001), valve circumference from 13+/-0.5 to 7.3+/-0.3 cm (P-value<0.0001), septolateral distance from 2.1+/-0.1 to 1.4+/-0.06 cm (P-value<0.01) and intercommissural distance from 3.4+/-0.1 to 2.7+/-0.03 cm (P-value<0.03). There was significant decrease in the septolateral distance at the level of A2-P2 with respect to other regions. These geometric changes were associated with the improvement in the NYHA class from 3.1+/-0.3 to 1.3+/-0.3 (P-value<0.002). The mitral valve annuloplasty with the Geoform ring restores leaflet coaptation and eliminates mitral regurgitation by effectively modifying the mitral annular geometry.

  7. Fluid Dynamics of the Heart and its Valves

    NASA Astrophysics Data System (ADS)

    Peskin, Charles S.

    1997-11-01

    The fluid dynamics of the heart involve the interaction of blood, a viscous incompressible fluid, with the flexible, elastic, fiber-reinforced heart valve leaflets that are immersed in that fluid. Neither the fluid motion nor the valve leaflet motion are known in advance: both must be computed simultaneously by solving their coupled equations of motion. This can be done by the immersed boundary method(Peskin CS and McQueen DM: A general method for the computer simulation of biological systems interacting with fluids. In: Biological Fluid Dynamics (Ellington CP and Pedley TJ, eds.), The Company of Biologists Limited, Cambridge UK, 1995, pp. 265-276.), which can be extended to incorporate the contractile fiber architecture of the muscular heart walls as well as the valve leaflets and the blood. In this way we arrive at a three-dimensional computer model of the heart(Peskin CS and McQueen DM: Fluid dynamics of the heart and its valves. In: Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology (Othmer HG, Adler FR, Lewis MA, and Dallon JC, eds.), Prentice-Hall, Englewood Cliffs NJ, 1996, pp. 309-337.), which can be used as a test chamber for the design of prosthetic cardiac valves, and also to study the function of the heart in health and in disease. Numerical solutions of the equations of cardiac fluid dynamics obtained by the immersed boundary method will be presented in the form of a video animation of the beating heart.

  8. Effects of Mechanical Ventilation on Heart Geometry and Mitral Valve Leaflet Coaptation During Percutaneous Edge-to-Edge Mitral Valve Repair.

    PubMed

    Patzelt, Johannes; Zhang, Yingying; Seizer, Peter; Magunia, Harry; Henning, Andreas; Riemlova, Veronika; Patzelt, Tara A E; Hansen, Marc; Haap, Michael; Riessen, Reimer; Lausberg, Henning; Walker, Tobias; Reutershan, Joerg; Schlensak, Christian; Grasshoff, Christian; Simon, Dan I; Rosenberger, Peter; Schreieck, Juergen; Gawaz, Meinrad; Langer, Harald F

    2016-01-25

    This study sought to evaluate a ventilation maneuver to facilitate percutaneous edge-to-edge mitral valve repair (PMVR) and its effects on heart geometry. In patients with challenging anatomy, the application of PMVR is limited, potentially resulting in insufficient reduction of mitral regurgitation (MR) or clip detachment. Under general anesthesia, however, ventilation maneuvers can be used to facilitate PMVR. A total of 50 consecutive patients undergoing PMVR were included. During mechanical ventilation, different levels of positive end-expiratory pressure (PEEP) were applied, and parameters of heart geometry were assessed using transesophageal echocardiography. We found that increased PEEP results in elevated central venous pressure. Specifically, central venous pressure increased from 14.0 ± 6.5 mm Hg (PEEP 3 mm Hg) to 19.3 ± 5.9 mm Hg (PEEP 20 mm Hg; p < 0.001). As a consequence, the reduced pre-load resulted in reduction of the left ventricular end-systolic diameter from 43.8 ± 10.7 mm (PEEP 3 mm Hg) to 39.9 ± 11.0 mm (PEEP 20 mm Hg; p < 0.001), mitral valve annulus anterior-posterior diameter from 32.4 ± 4.3 mm (PEEP 3 mm Hg) to 30.5 ± 4.4 mm (PEEP 20 mm Hg; p < 0.001), and the medio-lateral diameter from 35.4 ± 4.2 mm to 34.1 ± 3.9 mm (p = 0.002). In parallel, we observed a significant increase in leaflet coaptation length from 3.0 ± 0.8 mm (PEEP 3 mm Hg) to 5.4 ± 1.1 mm (PEEP 20 mm Hg; p < 0.001). The increase in coaptation length was more pronounced in MR with functional or mixed genesis. Importantly, a coaptation length >4.9 mm at PEEP of 10 mm Hg resulted in a significant reduction of PMVR procedure time (152 ± 49 min to 116 ± 26 min; p = 0.05). In this study, we describe a novel ventilation maneuver improving mitral valve coaptation length during the PMVR procedure, which facilitates clip positioning. Our observations could help to improve PMVR therapy and could make nonsurgical candidates accessible to PMVR therapy, particularly in

  9. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    PubMed Central

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  10. Tricuspid leaflet resection in an open beating heart for the creation of a canine tricuspid regurgitation model.

    PubMed

    Xie, Xu-jing; Liao, Sheng-jie; Wu, Yue-heng; Lu, Cong; Zhu, Ping; Fei, Hong-wen; Xiao, Xue-jun; Huang, Huan-lei

    2016-02-01

    Outcomes of tricuspid valve replacement are poor, partly due to right heart remodelling. The research on its underlying mechanisms is hampered by a lack of animal models of tricuspid regurgitation (TR). Our objective was to create a reproducible and clinically compatible TR animal model to study right heart remodelling caused by TR. Fourteen juvenile male Beagle dogs were divided randomly into an intervention group (n = 11) and a sham-operated control group (n = 3). The intervention group underwent thoracotomy and right atrial incision following superior and inferior vena caval occlusion. The anterior leaflet, together with the chordae, of the tricuspid valve was resected in eight dogs ('one leaflet' group), whereas both anterior and posterior leaflets, together with the chordae, were resected in three dogs ('two leaflets' group). The right atrium and chest were then closed. The control group underwent the same procedure, except leaflet resection. One dog from the 'two leaflets' group and one control dog were sacrificed and autopsy was performed at 12 months post-surgery. All dogs survived over the 1-year observation period postoperatively. TR grade IV occurred immediately postoperatively in the 'one leaflet' group, and TR grade IV plus in the 'two leaflets' group. The overall procedure lasted 30-40 min, and the mean time of vena caval occlusion was 87 ± 10 s. Central venous pressure increased from 6 ± 1.2 at baseline to 13 ± 1.7 mmHg (P < 0.01). By 12 months after TR creation, both in the 'one leaflet' group and in the 'two leaflets' group, the right atrial area, tricuspid annular diameter and right ventricular index of myocardial performance increased significantly, right ventricular fractional area change and tricuspid annular plane systolic excursion decreased significantly. Autopsy of the intervention dog revealed oedema, ascites and cirrhosis. Our surgical technique to create a TR animal model was reproducible with high success and survival rates. This

  11. Robotic Posterior Mitral Leaflet Repair: Neochordal versus Resectional Techniques

    PubMed Central

    Mihaljevic, Tomislav; Pattakos, Gregory; Gillinov, A. Marc; Bajwa, Gurjyot; Planinc, Mislav; Williams, Sarah J.; Blackstone, Eugene H.

    2013-01-01

    Background Resectional techniques are the established method of posterior mitral valve leaflet repair for degenerative disease; however, use of neochordae in a robotically assisted approach is gaining acceptance because of its versatility for difficult multi-segment disease. The purposes of this study were to compare the versatility, safety, and effectiveness of neochordal vs. resectional techniques for robotic posterior mitral leaflet repair. Methods From 12/2007 to 7/2010, 334 patients underwent robotic posterior mitral leaflet repair for degenerative disease by a resectional (n=248) or neochordal (n=86) technique. Outcomes were compared unadjusted and after propensity score matching. Results Neochordae were more likely to be used than resection in patients with two (28% vs. 13%, P=.002) or three (3.7% vs. 0.87%, P=.08) diseased posterior leaflet segments. Three resection patients (0.98%) but no neochordal patient required reoperation for hemodynamically significant systolic anterior motion (SAM). Residual mitral regurgitation (MR) at hospital discharge was similar for matched neochordal vs. resection patients (P=.14) (MR 0+, 82% vs. 89%; MR 1+, 14% vs. 8.2%; MR 2+, 2.3% vs. 2.6%; one neochordal patient had 4+ MR and was reoperated). Among matched patients, postoperative mortality and morbidity were similarly low. Conclusion Compared with a resectional technique, robotic posterior mitral leaflet repair with neochordae is associated with shorter operative times and no occurrence of SAM. The versatility, effectiveness, and safety of this repair make it a good choice for patients with advanced multi-segment disease. PMID:23103008

  12. Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation

    PubMed Central

    Spina, Roberto; Anthony, Chris; Muller, David WM

    2015-01-01

    Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674

  13. A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves.

    PubMed

    Sotiropoulos, Fotis; Borazjani, Iman

    2009-03-01

    In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid-structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment.

  14. A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves

    PubMed Central

    Borazjani, Iman

    2009-01-01

    In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid–structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment. PMID:19194734

  15. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    PubMed

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Hybrid textile heart valve prosthesis: preliminary in vitro evaluation.

    PubMed

    Vaesken, Antoine; Pidancier, Christian; Chakfe, Nabil; Heim, Frederic

    2016-09-22

    Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.

  17. Design and efficacy of a single-use bioreactor for heart valve tissue engineering.

    PubMed

    Converse, Gabriel L; Buse, Eric E; Neill, Kari R; McFall, Christopher R; Lewis, Holley N; VeDepo, Mitchell C; Quinn, Rachael W; Hopkins, Richard A

    2017-02-01

    Heart valve tissue engineering offers the promise of improved treatments for congenital heart disorders; however, widespread clinical availability of a tissue engineered heart valve (TEHV) has been hindered by scientific and regulatory concerns, including the lack of a disposable, bioreactor system for nondestructive valve seeding and mechanical conditioning. Here we report the design for manufacture and the production of full scale, functional prototypes of such a system. To evaluate the efficacy of this bioreactor as a tool for seeding, ovine aortic valves were decellularized and subjected to seeding with human mesenchymal stem cells (hMSC). The effects of pulsatile conditioning using cyclic waveforms tuned to various negative and positive chamber pressures were evaluated, with respect to the seeding of cells on the decellularized leaflet and the infiltration of seeded cells into the interstitium of the leaflet. Infiltration of hMSCs into the aortic valve leaflet was observed following 72 h of conditioning under negative chamber pressure. Additional conditioning under positive pressure improved cellular infiltration, while retaining gene expression within the MSC-valve interstitial cell phenotype lineage. This protocol resulted in a subsurface pilot population of cells, not full tissue recellularization. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 249-259, 2017. © 2015 Wiley Periodicals, Inc.

  18. Tricuspid regurgitation due to chest trauma: an unusual laceration around the annulus of the anterior leaflet.

    PubMed

    Ishii, K; Koga, Y; Maeda, M; Nakamura, K; Sekiya, R; Yonezawa, T; Onitsuka, T; Shibata, K

    1988-01-01

    A 70-year-old male with tricuspid regurgitation due to a blunt chest trauma inflicted 16 years previously underwent prosthetic valve replacement. At surgery, a tear, which produced tricuspid regurgitation, was found around the annulus of the anterior leaflet of the tricuspid valve. Since this area has not been reported as a location for heart trauma-producing tricuspid regurgitation, a possible mechanism of tricuspid regurgitation is discussed in this patient.

  19. Traumatic rupture of the tricuspid valve and multi-modality imaging

    PubMed Central

    Corneli, Mariana; Conde, Diego; Ronderos, Ricardo

    2014-01-01

    Introduction Motor vehicle accident (MVA) account for most cases of traumatic rupture of the tricuspid valve. Valve rupture during an MVA is generated by an abrupt deceleration coupled with an increase in right-side cardiac pressures (Valsalva maneuver and thorax compression). Case A 39-year-old asymptomatic man was referred for an echocardiogram due to the presence of a systolic murmur. He had no prior significant medical history, except for a remote MVA 3 years ago. Real-time 3D echocardiography (RT3DE) showed a tear in the body of the anterior leaflet and not at the cord, as was suggested by two-dimensional transthoracic echocardiography (2D-TTE). Based on these findings, the mechanism was considered anterior leaflet rupture of the tricuspid valve, secondary to chest blunt trauma. The anterior leaflet was repaired using two polytetrafluoroethylene sutures, and tricuspid annuloplasty with an Edwards ring was performed. Conclusions Multimodality imaging helps to determine timing of surgery in asymptomatic traumatic tricuspid rupture. The combination of echocardiography and magnetic resonance imaging provide information of volumetric data and contractility of the right ventricle (RV) during follow-up. RT3DE gives information relevant to the morphological and functional characterization of the valve, allowing the planning of appropriate surgical procedure. PMID:25414827

  20. Robotic artificial chordal replacement for repair of mitral valve prolapse.

    PubMed

    Brunsting, Louis A; Rankin, J Scott; Braly, Kimberly C; Binford, Robert S

    2009-07-01

    Artificial chordal replacement (ACR) has emerged as a superior method of mitral valve repair with excellent early and late efficacy. It is also ideal to combine with robotic techniques for correction of mitral prolapse, and this article presents a current method of robotic Gore-Tex ACR. Patients with isolated posterior leaflet prolapse are approached with the fourth-generation DaVinci robotic system and endoaortic balloon occlusion. A pledgetted anchor stitch is placed in a papillary muscle, and a 2-o Gore-Tex suture is passed through the anchor pledget. After full annuloplasty ring placement, the Gore-Tex suture is woven into the prolapsing segment and positioned temporarily with robotic forceps. Chordal length is then "adjusted" by lengthening or shortening the temporary knot over 1-cm increments as the valve is tested by injection of cold saline into the ventricle. After achieving good leaflet position and valve competence, the chord is tied permanently. The "adjustable" ACR procedure preserves leaflet surface area and produces a competent valve in the majority of patients. Postoperative transesophageal echo shows a large surface area of coaptation. Patient recovery is facilitated by the minimally invasive approach, while long-term stability of similar open ACR techniques have been excellent with a 2% to 3% failure rate over 10 years of follow-up. Robotic Gore-Tex ACR without leaflet resection is a reproducible procedure that simplifies mitral repair for prolapse. The outcomes observed in early robotic applications have been excellent. It is suggested that most patients with simple prolapse might validly be approached in this manner.

  1. Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.

    PubMed

    Mohammadi, Siamak; Baillot, Richard; Voisine, Pierre; Mathieu, Patrick; Dagenais, François

    2006-08-01

    Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical presentation of structural valve deterioration in the Freestyle stentless bioprosthesis. Between January 1993 and August 2005, 608 patients underwent aortic valve replacement with a Freestyle stentless bioprosthesis. The implantation technique was subcoronary in 475 patients and a root replacement in 133 patients. Mean overall follow-up was 5.6 +/- 3.4 years. Follow-up was complete in all patients. Clinical and echocardiographic follow-ups were conducted prospectively. Freedom from structural valve deterioration was 95.8% at 10 years. Twelve patients showed evidence of structural valve deterioration and underwent reoperation for aortic regurgitation (n = 10) or aortic stenosis (n = 2). The mean age of patients with structural valve deterioration was significantly lower than patients without structural valve deterioration (62.6 +/- 8.2 years vs 68.6 +/- 8.3 years, P = .02). The median time between implantation and explantation was 8.7 years (range: 1.9-13.3 years). Eleven structural valve deteriorations occurred after subcoronary implantation, and 1 structural valve deterioration occurred after root implantation (P = .4). The mechanisms of structural valve deterioration were leaflet tears in 10 patients (6 in the left coronary cusp and 4 in the right coronary cusp), severe valve calcification in 1 patient, and cusp fibrosis in 1 patient. The interval between onset of symptoms and reoperation was acute or subacute in 10 patients. At 10 years, the Freestyle stentless bioprosthesis shows excellent freedom from structural valve deterioration. Structural valve deterioration in the Freestyle

  2. Particle Image Velocimetry studies of bicuspid aortic valve hemodynamics

    NASA Astrophysics Data System (ADS)

    Saikrishnan, Neelakantan; Yap, Choon-Hwai; Yoganathan, Ajit P.

    2010-11-01

    Bicuspid aortic valves (BAVs) are a congenital anomaly of the aortic valve with two fused leaflets, affecting about 1-2% of the population. BAV patients have much higher incidence of valve calcification & aortic dilatation, which may be related to altered mechanical forces from BAV hemodynamics. This study aims to characterize BAV hemodynamics using Particle Image Velocimetry(PIV). BAV models are constructed from normal explanted porcine aortic valves by suturing two leaflets together. The valves are mounted in an acrylic chamber with two sinuses & tested in a pulsatile flow loop at physiological conditions. 2D PIV is performed to obtain flow fields in three planes downstream of the valve. The stenosed BAV causes an eccentric jet, resulting in a very strong vortex in the normal sinus. The bicuspid sinus vortex appears much weaker, but more unstable. Unsteady oscillatory shear stresses are also observed, which have been associated with adverse biological response; characterization of the hemodynamics of BAVs will provide the first step to understanding these processes better. Results from multiple BAV models of varying levels of stenosis will be presented & higher stenosis corresponded to stronger jets & increased aortic wall shear stresses.

  3. Early Activation of Growth Pathways in Mitral Leaflets Exposed to Aortic Regurgitation: New Insights from an Animal Model.

    PubMed

    Marsit, Ons; Royer, Olivier; Drolet, Marie-Claude; Arsenault, Marie; Couet, Jacques; Morin, Stéphane; Levine, Robert A; Pibarot, Philippe; Beaudoin, Jonathan

    2017-05-01

    Mitral leaflet enlargement in patients with chronic aortic regurgitation (AR) has been identified as an adaptive mechanism potentially able to prevent functional mitral regurgitation (FMR) in response to left ventricular (LV) dilatation. The timing of valve enlargement is not known, and the related mechanisms are largely unexplored. AR was induced in 58 rats, and another 54 were used as sham controls. Animals were euthanized at different time points after AR creation (48 h, one week, and three months), and AR severity, FMR and LV dilatation were assessed using echocardiography. Mitral valves were harvested to document the reactivation of embryonic growth pathways. AR animals had increased LV dimensions and mitral annulus size. No animal developed FMR. No change in leaflet length or thickness was seen at 48 h; however, anterior mitral leaflets were longer and thicker in AR animals at one week and three months. Molecular changes were present early (at 48 h and at one week), with positive staining for transforming growth factor-b1 (TGF-b1), Alpha-smooth muscle actin (α-SMA) and matrix metalloproteinase-2 (MMP-2), which suggested active matrix remodeling. Increased gene expression for collagen 1, TGF-β1, α-SMA and MMP-2 was found in the mitral valve at 48 h and at one week, but after three months their expression had returned to normal. This model of AR induces active expansion and thickening of the mitral leaflets. Growth signals are expressed acutely, but not at three months, which suggests that most of this enlargement occurs at an early stage. The stimulation of valvular growth could represent a new strategy for the prevention of FMR.

  4. Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study.

    PubMed

    Sigüenza, Julien; Pott, Desiree; Mendez, Simon; Sonntag, Simon J; Kaufmann, Tim A S; Steinseifer, Ulrich; Nicoud, Franck

    2018-04-01

    The complex fluid-structure interaction problem associated with the flow of blood through a heart valve with flexible leaflets is investigated both experimentally and numerically. In the experimental test rig, a pulse duplicator generates a pulsatile flow through a biomimetic rigid aortic root where a model of aortic valve with polymer flexible leaflets is implanted. High-speed recordings of the leaflets motion and particle image velocimetry measurements were performed together to investigate the valve kinematics and the dynamics of the flow. Large eddy simulations of the same configuration, based on a variant of the immersed boundary method, are also presented. A massively parallel unstructured finite-volume flow solver is coupled with a finite-element solid mechanics solver to predict the fluid-structure interaction between the unsteady flow and the valve. Detailed analysis of the dynamics of opening and closure of the valve are conducted, showing a good quantitative agreement between the experiment and the simulation regarding the global behavior, in spite of some differences regarding the individual dynamics of the valve leaflets. A multicycle analysis (over more than 20 cycles) enables to characterize the generation of turbulence downstream of the valve, showing similar flow features between the experiment and the simulation. The flow transitions to turbulence after peak systole, when the flow starts to decelerate. Fluctuations are observed in the wake of the valve, with maximum amplitude observed at the commissure side of the aorta. Overall, a very promising experiment-vs-simulation comparison is shown, demonstrating the potential of the numerical method. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.

    PubMed

    Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T

    2000-04-01

    Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.

  6. Cavitation behavior observed in three monoleaflet mechanical heart valves under accelerated testing conditions.

    PubMed

    Lo, Chi-Wen; Liu, Jia-Shing; Li, Chi-Pei; Lu, Po-Chien; Hwang, Ned H

    2008-01-01

    Accelerated testing provides a substantial amount of data on mechanical heart valve durability in a short period of time, but such conditions may not accurately reflect in vivo performance. Cavitation, which occurs during mechanical heart valve closure when local flow field pressure decreases below vapor pressure, is thought to play a role in valve damage under accelerated conditions. The underlying flow dynamics and mechanisms behind cavitation bubble formation are poorly understood. Under physiologic conditions, random perivalvular cavitation is difficult to capture. We applied accelerated testing at a pulse rate of 600 bpm and transvalvular pressure of 120 mm Hg, with synchronized videographs and high-frequency pressure measurements, to study cavitation of the Medtronic Hall Standard (MHS), Medtronic Hall D-16 (MHD), and Omni Carbon (OC) valves. Results showed cavitation bubbles between 340 and 360 micros after leaflet/housing impact of the MHS, MHD, and OC valves, intensified by significant leaflet rebound. Squeeze flow, Venturi, and water hammer effects each contributed to cavitation, depending on valve design.

  7. Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.

    PubMed

    Braunberger, E; Deloche, A; Berrebi, A; Abdallah, F; Celestin, J A; Meimoun, P; Chatellier, G; Chauvaud, S; Fabiani, J N; Carpentier, A

    2001-09-18

    Mitral valve repair is considered the gold standard in surgery of degenerative mitral valve insufficiency (MVI), but the long-term results (>20 years) are unknown. We reviewed the first 162 consecutive patients who underwent mitral valve repair between 1970 and 1984 for MVI due to nonrheumatic disease. The cause of MVI was degenerative in 146 patients (90%) and bacterial endocarditis in 16 patients (10%). MVI was isolated or, in 18 cases, associated with tricuspid insufficiency. The mean age of the 162 patients (104 men and 58 women) was 56+/-10 years (age range 22 to 77 years). New York Heart Association functional class was I, II, III, and IV in 2%, 39%, 52%, and 7% of patients, respectively. The mean cardiothoracic ratio was 0.58+/-0.07 (0.4 to 0.8), and 72 (45%) patients had atrial fibrillation. Valve analysis showed that the main mechanism of MVI was type II Carpentier's functional classification in 152 patients. The leaflet prolapse involved the posterior leaflet in 93 patients, the anterior leaflet in 28 patients, and both leaflets in 31 patients. Surgical technique included a Carpentier's ring annuloplasty in all cases, a valve resection in 126 patients, and shortening or transposition of chordae in 49 patients. During the first postoperative month, there were 3 deaths (1.9%) and 3 reoperations (2 valve replacements and 1 repeat repair [1.9%]). Six patients were lost to follow-up. The remaining 151 patients with mitral valve repair were followed during a median of 17 years (range 1 to 29 years; 2273 patient-years). The 20-year Kaplan-Meier survival rate was 48% (95% CI 40% to 57%), which is similar to the survival rate for a normal population with the same age structure. The 20-year rates were 19.3% (95% CI 11% to 27%) for cardiac death and 26% (95% CI 17% to 35%) for cardiac morbidity/mortality (including death from a cardiac cause, stroke, and reoperation). During the 20 years of follow-up, 7 patients were underwent surgery at 3, 7, 7, 8, 8, 10, or 12

  8. Premeasured Chordal Loops for Mitral Valve Repair.

    PubMed

    Gillinov, Marc; Quinn, Reed; Kerendi, Faraz; Gaudiani, Vince; Shemin, Richard; Barnhart, Glenn; Raines, Edward; Gerdisch, Marc W; Banbury, Michael

    2016-09-01

    Premeasured expanded polytetrafluoroethylene chordal loops with integrated sutures for attachment to the papillary muscle and leaflet edges facilitate correction of mitral valve prolapse. Configured as a group of 3 loops (length range 12 to 24 mm), the loops are attached to a pledget that is passed through the papillary muscle and tied. Each of the loops has 2 sutures with attached needles; these needles are passed through the free edge of the leaflet and then the sutures are tied to each other, securing the chordal loop to the leaflet. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Side-Specific Endothelial-Dependent Regulation of Aortic Valve Calcification

    PubMed Central

    Richards, Jennifer; El-Hamamsy, Ismail; Chen, Si; Sarang, Zubair; Sarathchandra, Padmini; Yacoub, Magdi H.; Chester, Adrian H.; Butcher, Jonathan T.

    2014-01-01

    Arterial endothelial cells maintain vascular homeostasis and vessel tone in part through the secretion of nitric oxide (NO). In this study, we determined how aortic valve endothelial cells (VEC) regulate aortic valve interstitial cell (VIC) phenotype and matrix calcification through NO. Using an anchored in vitro collagen hydrogel culture system, we demonstrate that three-dimensionally cultured porcine VIC do not calcify in osteogenic medium unless under mechanical stress. Co-culture with porcine VEC, however, significantly attenuated VIC calcification through inhibition of myofibroblastic activation, osteogenic differentiation, and calcium deposition. Incubation with the NO donor DETA-NO inhibited VIC osteogenic differentiation and matrix calcification, whereas incubation with the NO blocker l-NAME augmented calcification even in 3D VIC–VEC co-culture. Aortic VEC, but not VIC, expressed endothelial NO synthase (eNOS) in both porcine and human valves, which was reduced in osteogenic medium. eNOS expression was reduced in calcified human aortic valves in a side-specific manner. Porcine leaflets exposed to the soluble guanylyl cyclase inhibitor ODQ increased osteocalcin and α-smooth muscle actin expression. Finally, side-specific shear stress applied to porcine aortic valve leaflet endothelial surfaces increased cGMP production in VEC. Valve endothelial-derived NO is a natural inhibitor of the early phases of valve calcification and therefore may be an important regulator of valve homeostasis and pathology. PMID:23499458

  10. Design of Bioprosthetic Aortic Valves using biaxial test data.

    PubMed

    Dabiri, Y; Paulson, K; Tyberg, J; Ronsky, J; Ali, I; Di Martino, E; Narine, K

    2015-01-01

    Bioprosthetic Aortic Valves (BAVs) do not have the serious limitations of mechanical aortic valves in terms of thrombosis. However, the lifetime of BAVs is too short, often requiring repeated surgeries. The lifetime of BAVs might be improved by using computer simulations of the structural behavior of the leaflets. The goal of this study was to develop a numerical model applicable to the optimization of durability of BAVs. The constitutive equations were derived using biaxial tensile tests. Using a Fung model, stress and strain data were computed from biaxial test data. SolidWorks was used to develop the geometry of the leaflets, and ABAQUS finite element software package was used for finite element calculations. Results showed the model is consistent with experimental observations. Reaction forces computed by the model corresponded with experimental measurements when the biaxial test was simulated. As well, the location of maximum stresses corresponded to the locations of frequent tearing of BAV leaflets. Results suggest that BAV design can be optimized with respect to durability.

  11. klf2a couples mechanotransduction and zebrafish valve morphogenesis through fibronectin synthesis

    PubMed Central

    Steed, Emily; Faggianelli, Nathalie; Roth, Stéphane; Ramspacher, Caroline; Concordet, Jean-Paul; Vermot, Julien

    2016-01-01

    The heartbeat and blood flow signal to endocardial cell progenitors through mechanosensitive proteins that modulate the genetic program controlling heart valve morphogenesis. To date, the mechanism by which mechanical forces coordinate tissue morphogenesis is poorly understood. Here we use high-resolution imaging to uncover the coordinated cell behaviours leading to heart valve formation. We find that heart valves originate from progenitors located in the ventricle and atrium that generate the valve leaflets through a coordinated set of endocardial tissue movements. Gene profiling analyses and live imaging reveal that this reorganization is dependent on extracellular matrix proteins, in particular on the expression of fibronectin1b. We show that blood flow and klf2a, a major endocardial flow-responsive gene, control these cell behaviours and fibronectin1b synthesis. Our results uncover a unique multicellular layering process leading to leaflet formation and demonstrate that endocardial mechanotransduction and valve morphogenesis are coupled via cellular rearrangements mediated by fibronectin synthesis. PMID:27221222

  12. C-reactive protein in degenerative aortic valve stenosis

    PubMed Central

    Sanchez, Pedro L; Mazzone, AnnaMaria

    2006-01-01

    Degenerative aortic valve stenosis includes a range of disorder severity from mild leaflet thickening without valve obstruction, "aortic sclerosis", to severe calcified aortic stenosis. It is a slowly progressive active process of valve modification similar to atherosclerosis for cardiovascular risk factors, lipoprotein deposition, chronic inflammation, and calcification. Systemic signs of inflammation, as wall and serum C-reactive protein, similar to those found in atherosclerosis, are present in patients with degenerative aortic valve stenosis and may be expression of a common disease, useful in monitoring of stenosis progression. PMID:16774687

  13. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    PubMed

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  14. A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications.

    PubMed

    Rosa, Benoit; Machaidze, Zurab; Shin, Borami; Manjila, Sunil; Brown, David W; Baird, Christopher W; Mayer, John E; Dupont, Pierre E

    2017-11-01

    This paper provides detailed instructions for constructing low-cost bioprosthetic semilunar valves for animal research and clinical training. This work fills an important gap between existing simulator training valves and clinical valves by providing fully functioning designs that can be employed in ex vivo and in vivo experiments and can also be modified to model valvular disease. Valves are constructed in 4 steps consisting of creating a metal frame, covering it with fabric and attaching a suture ring and leaflets. Computer-aided design files are provided for making the frame from wire or by metal 3D printing. The covering fabric and suturing ring are made from materials readily available in a surgical lab, while the leaflets are made from pericardium. The entire fabrication process is described in figures and in a video. To demonstrate disease modelling, design modifications are described for producing paravalvular leaks, and these valves were evaluated in porcine ex vivo (n = 3) and in vivo (n = 6) experiments. Porcine ex vivo and acute in vivo experiments demonstrate that the valves can replicate the performance of clinical valves for research and training purposes. Surgical implantation is similar, and echocardiograms are comparable to clinical valves. Furthermore, valve leaflet function was satisfactory during acute in vivo tests with little central regurgitation, while the paravalvular leak modifications consistently produced leaks in the desired locations. The detailed design procedure presented here, which includes a tutorial video and computer-aided design files, should be of substantial benefit to researchers developing valve disease models and to clinicians developing realistic valve training systems. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Heart valves from polyester fibers: a preliminary 6-month in vivo study.

    PubMed

    Vaesken, Antoine; Pelle, Anne; Pavon-Djavid, Graciela; Rancic, Jeanne; Chakfe, Nabil; Heim, Frederic

    2018-06-27

    Transcatheter aortic valve implantation (TAVI) has become a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in TAVI procedures for over a decade, with over 150,000 implantations to date. However, with only 6 years of follow up, little is known about the long-term durability of biological tissue. Moreover, the high cost of tissue harvesting and chemical treatment procedures favor the development of alternative synthetic valve leaflet materials. In that context, textile polyester [polyethylene terephthalate (PET)] could be considered as an interesting candidate to replace the biological valve leaflets in TAVI procedures. However, no result is available in the literature about the behavior of textile once in contact with biological tissue in the valve position. The interaction of synthetic textile material with living tissues should be comparable to biological tissue. The purpose of this preliminary work is to compare the in vivo performances of various woven textile PET valves over a 6-month period in order to identify favorable textile construction features. In vivo results indicate that fibrosis as well as calcium deposit can be limited with an appropriate material design.

  16. Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect.

    PubMed

    Bol Raap, Goris; Koning, Anton H J; Scohy, Thierry V; ten Harkel, A Derk-Jan; Meijboom, Folkert J; Kappetein, A Pieter; van der Spek, Peter J; Bogers, Ad J J C

    2007-02-16

    This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D) echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD). 12 data sets from intraoperative epicardial echocardiographic studies in 5 operations (patient age at operation 3 weeks to 4 years and bodyweight at operation 3.8 to 17.2 kg) after surgical closure of VSD were included in the study. The data sets were analysed as two-dimensional (2D) images on the screen of the ultrasound system as well as holograms in an I-space virtual reality (VR) system. The 2D images were assessed for tricuspid valve function. In the I-Space, a 6 degrees-of-freedom controller was used to create the necessary projectory positions and cutting planes in the hologram. The holograms were used for additional assessment of tricuspid valve leaflet mobility. All data sets could be used for 2D as well as holographic analysis. In all data sets the area of interest could be identified. The 2D analysis showed no tricuspid valve stenosis or regurgitation. Leaflet mobility was considered normal. In the virtual reality of the I-Space, all data sets allowed to assess the tricuspid leaflet level in a single holographic representation. In 3 holograms the septal leaflet showed restricted mobility that was not appreciated in the 2D echocardiogram. In 4 data sets the posterior leaflet and the tricuspid papillary apparatus were not completely included. This report shows that dynamic holographic imaging of intraoperative postoperative echocardiographic data regarding tricuspid valve function after VSD closure is feasible. Holographic analysis allows for additional tricuspid valve leaflet mobility analysis. The large size of the probe, in relation to small size of the patient, may preclude a complete data set. At the moment the requirement of an I-Space VR system limits the applicability in virtual reality 3D

  17. Planar biaxial testing of heart valve cusp replacement biomaterials: Experiments, theory and material constants.

    PubMed

    Labrosse, Michel R; Jafar, Reza; Ngu, Janet; Boodhwani, Munir

    2016-11-01

    Aortic valve (AV) repair has become an attractive option to correct aortic insufficiency. Yet, cusp reconstruction with various cusp replacement materials has been associated with greater long-term repair failures, and it is still unknown how such materials mechanically compare with native leaflets. We used planar biaxial testing to characterize six clinically relevant cusp replacement materials, along with native porcine AV leaflets, to ascertain which materials would be best suited for valve repair. We tested at least six samples of: 1) fresh autologous porcine pericardium (APP), 2) glutaraldehyde fixed porcine pericardium (GPP), 3) St Jude Medical pericardial patch (SJM), 4) CardioCel patch (CC), 5) PeriGuard (PG), 6) Supple PeriGuard (SPG) and 7) fresh porcine AV leaflets (PC). We introduced efficient displacement-controlled testing protocols and processing, as well as advanced convexity requirements on the strain energy functions used to describe the mechanical response of the materials under loading. The proposed experimental and data processing pipeline allowed for a robust in-plane characterization of all the materials tested, with constants determined for two Fung-like hyperelastic, anisotropic strain energy models. Overall, CC and SPG (respectively PG) patches ranked as the closest mechanical equivalents to young (respectively aged) AV leaflets. Because the native leaflets as well as CC, PG and SPG patches exhibit significant anisotropic behaviors, it is suggested that the fiber and cross-fiber directions of these replacement biomaterials be matched with those of the host AV leaflets. The long-term performance of cusp replacement materials would ideally be evaluated in large animal models for AV disease and cusp repair, and over several months or more. Given the unavailability and impracticality of such models, detailed information on stress-strain behavior, as studied herein, and investigations of durability and valve dynamics will be the best surrogates

  18. Mid- to long-term outcome comparison of the Medtronic Hancock II and bi-leaflet mechanical aortic valve replacement in patients younger than 60 years of age: a propensity-matched analysis.

    PubMed

    Wang, Yin; Chen, Si; Shi, Jiawei; Li, Geng; Dong, Nianguo

    2016-03-01

    This study aims to compare mid-long-term clinical outcomes between patients younger than 60 years of age undergoing bioprosthetic and mechanical aortic valve replacement. From January 2002 to December 2009, patients younger than 60 years of age who received Medtronic Hancock II porcine bioprostheses were selected and compared with those who received mechanical bi-leaflet valves in the aortic position. A stepwise logistic regression propensity score identified a subset of 112 evenly matched patient-pairs. Mid-long-term outcomes of survival, valve-related reoperations, thromboembolic events and bleeding events were assessed. The follow-up was only 95.1% complete. Fourteen measurable variables were statistically similar for the matched cohort. Postoperative in-hospital mortality was 3.6% (bioprosthetic valves) and 2.7% (mechanical valves) (P = 0.700). Survival at 5 and 10 years was 96.3 and 88.7% for patients receiving bioprosthetic valve replacement versus 96.3 and 87.9% for patients receiving mechanical valve replacement (P = 0.860), respectively. At 5 and 10 years after operations, freedom from valve-related reoperation was 97.2 and 94.8% for patients receiving mechanical valve replacement, and 96.3 and 90.2% for patients receiving bioprosthetic valve replacement (P = 0.296), respectively. There was no difference between freedom from thromboembolic events (P = 0.528) and bleeding events (P = 0.128) between the matched groups during the postoperative 10 years. In patients younger than 60 years of age undergoing aortic valve replacement, mid-long-term survival rate was similar for patients receiving bioprosthetic versus mechanical valve replacement. Bioprosthetic valves were associated with a trend for a lower risk of anticoagulation treatment and did not have significantly greater likelihood of a reoperation. These findings suggest that a bioprosthetic valve may be a reasonable choice for AVR in patients younger than 60 years of age. © The Author 2015. Published by

  19. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    PubMed Central

    2012-01-01

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790

  20. Idiopathic mitral valve disease in a patient presenting with Axenfeld-Rieger syndrome.

    PubMed

    Antevil, Jared; Umakanthan, Ramanan; Leacche, Marzia; Brewer, Zachary; Solenkova, Natalia; Byrne, John G; Greelish, James P

    2009-05-01

    A 33-year-old, previously healthy male presented with respiratory distress and underwent intubation. A physical examination revealed a holosystolic murmur and pupillary abnormalities. Echocardiography revealed a flail anterior mitral valve leaflet with ruptured chordae and severe mitral regurgitation. The patient underwent urgent mitral valve replacement and tolerated the procedure well. The mitral valve leaflet was myxomatous and calcified -- an unusual find in such a patient. An ophthalmology consultation was obtained and the patient diagnosed with Axenfeld-Rieger syndrome, a disorder of the anterior ocular chamber that has been associated with cardiac malformations. The present case report adds to the body of literature which suggests a correlation between Axenfeld-Rieger syndrome and valvular abnormalities. Hence, it is believed prudent that patients with Axenfeld-Rieger syndrome should undergo echocardiographic screenings for valvular abnormalities.

  1. Development of a completely autologous valved conduit with the sinus of Valsalva using in-body tissue architecture technology: a pilot study in pulmonary valve replacement in a beagle model.

    PubMed

    Yamanami, Masashi; Yahata, Yuki; Uechi, Masami; Fujiwara, Megumi; Ishibashi-Ueda, Hatsue; Kanda, Keiichi; Watanabe, Taiji; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2010-09-14

    We developed autologous prosthetic implants by simple and safe in-body tissue architecture technology. We present the first report on the development of autologous valved conduit with the sinus of Valsalva (BIOVALVE) by using this unique technology and its subsequent implantation in the pulmonary valves in a beagle model. A mold of BIOVALVE organization was assembled using 2 types of specially designed silicone rods with a small aperture in a trileaflet shape between them. The concave rods had 3 projections that resembled the protrusions of the sinus of Valsalva. The molds were placed in the dorsal subcutaneous spaces of beagle dogs for 4 weeks. The molds were covered with autologous connective tissues. BIOVALVEs with 3 leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds. These valves had adequate burst strength, similar to that of native valves. Tight valvular coaptation and sufficient open orifice area were observed in vitro. These BIOVALVEs were implanted to the main pulmonary arteries as allogenic conduit valves (n=3). Postoperative echocardiography demonstrated smooth movement of the leaflets with trivial regurgitation. Histological examination of specimens obtained at 84 days showed that the surface of the leaflet was covered by endothelial cells and neointima, including an elastin fiber network, and was formed at the anastomosis sides on the luminal surface of the conduit. We developed the first completely autologous BIOVALVE and successfully implanted these BIOVALVEs in a beagle model in a pilot study.

  2. A second prosthesis as a procedural rescue option in trans-apical aortic valve implantation.

    PubMed

    Kempfert, Jörg; Rastan, Ardawan J; Schuler, Gerhard; Linke, Axel; Holzhey, David; van Linden, Arnaud; Mohr, Friedrich-W; Walther, Thomas

    2011-07-01

    Trans-apical aortic valve implantation (TA-AVI) using the Edwards SAPIEN™ prosthesis has evolved to a routine procedure for selected high-risk elderly patients. In rare cases, misplacement of the SAPIEN™ valve (too low a position), dysfunction of the leaflets or perforation of the interventricular septum (ventricular septal defect, VSD) occurs and requires immediate implantation of a second prosthesis within the first one. Results of this 'bailout' maneuver have not been reported yet. Of 305 TA-AVI procedures, 15 patients required a second prosthesis due to dysfunctional leaflets (n = 6), low position (n = 7), or VSD (n = 2). Mean age was 82.5 ± 1.3 years, mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 45.5 ± 5.4, and Society of Thoracic Surgeons (STS) Score was 13.5 ± 1.5. All second SAPIEN™ valves could be implanted successfully within the first one. The second prosthesis solved leaflet dysfunction, sealed the VSD (lower position of the second prosthesis), or corrected the initial misplacement (higher position of the second prosthesis) in all patients. Within 30 days, four patients died (low cardiac output n = 3, all with preoperative ejection fraction (EF) <35%; intestinal ischemia n = 1). Intra-operative echocardiogram and angiogram revealed mild paravalvular leak in three and none/trace in 12 patients. Transvalvular gradients were low despite the implantation of the second valve (P(max)/mean 13.7 ± 4.3/6.4 ± 2.0). Placement of a second SAPIEN™ valve is a valuable 'bailout' technique in case of VSD, dysfunctional leaflets, or too low placement of the first prosthesis. The technique leads to an excellent functional result with low transvalvular gradients. The simple, straight, tubular stent design of the SAPIEN™ prosthesis may be the ideal design for such valve-in-valve procedures. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  3. Pivot design in bileaflet valves.

    PubMed

    Vallana, F; Rinaldi, S; Galletti, P M; Nguyen, A; Piwnica, A

    1992-01-01

    The design criteria leading to the development of a new bileaflet valve (Sorin Bicarbon) were derived from the analysis of functional requirements, the performance of existing prostheses, and the availability of an advanced carbon coating technology (Carbofilm). The hinge is the critical element affecting fluid dynamics, durability, and thrombus formation in bileaflet valves. A comparative study of three existing models led to a new hinge design that was based on coupling two spheric surfaces with different radii of curvature (leaflet pivot and hinge recess) and obtained by electroerosion into a Carbofilm-coated metallic housing. In this valve, the point of contact moves continuously by rolling, not sliding. This minimizes friction and wear and allows uninterrupted washing of the blood exposed surfaces even during diastole (a finding established in patients using transesophageal echocardiography). Tricuspid implantation without anticoagulation in 33 sheep did not lead to thrombotic events (follow-up, 40-400 days). In the first 36 clinical implants observed for 15 months (mitral position, size 29; two unrelated deaths), the mean diastolic gradient by echo Doppler was 4 +/- 1.25 mmHg; the functional area was 3.2 +/- 0.6 cm2. No leaflet fracture and no thrombotic or embolic complications were observed clinically using a standard anticoagulant regimen.

  4. Tricuspid and Mitral Valve Regurgitation with Bi-fascicular Block Following a Horse Kick.

    PubMed

    Kokubun, Tomoki; Oikawa, Masayoshi; Ichijo, Yasuhiro; Matsumoto, Yoshiyuki; Yokokawa, Tetsuro; Nakazato, Kazuhiko; Sato, Yoshiyuki; Takase, Shinya; Shinjo, Hiroharu; Yokoyama, Hitoshi; Suzuki, Hitoshi; Saitoh, Shu-Ichi; Takeishi, Yasuchika

    2018-06-01

    A 40-year-old man was transferred to our hospital following an isolated horse kick injury to the anterior chest wall. The case showed bi-fascicular block, severe tricuspid valve regurgitation due to ruptured chordae tendineae of the anterior leaflet, moderate mitral valve regurgitation due to prolapse of mitral anterior leaflet, and hypokinetic motion of the inferior septal wall. Both tricuspid and mitral insufficiency were completely repaired by a surgical operation. Fortunately, these injuries were not fatal in this case, but the comprehensive assessment of cardiac damage and careful observation are important for managing patients with cardiac injury.

  5. Effects of suture position on left ventricular fluid mechanics under mitral valve edge-to-edge repair.

    PubMed

    Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming

    2014-01-01

    Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.

  6. Bicuspid aortic valves are associated with increased wall and turbulence shear stress levels compared to trileaflet aortic valves.

    PubMed

    Saikrishnan, Neelakantan; Mirabella, Lucia; Yoganathan, Ajit P

    2015-06-01

    Congenital bicuspid aortic valves (BAVs) are associated with accelerated disease progression, such as leaflet calcification and ascending aorta dilatation. Although common underlying genetic factors have been implicated in accelerated disease in BAV patients, several studies have suggested that altered hemodynamics also play a role in this disease process. The present study compares turbulence and wall shear stress (WSS) measurements between various BAV and trileaflet aortic valve (TAV) models to provide information for mechanobiological models of BAV disease. BAV and TAV models were constructed from excised porcine aortic valves to simulate parametric variations in BAV stenosis, hemodynamics and geometry. Particle image velocimetry experiments were conducted at physiological pressure conditions to characterize velocity fields in the ascending aorta. The velocity fields were post-processed to calculate turbulence, viscous and wall shear stresses in the ascending aorta. Stenosed BAV models showed the presence of eccentric systolic jets, causing increased WSS. Lower cardiac output resulted in a narrower jet, lower turbulence and lower viscous shear stress (VSS). The specific severe stenosis BAV model studied here showed reduced WSS due to reduction in non-fused leaflet mobility. Dilation of the aorta did not affect any turbulence or VSS, but reduced the WSS. In comparison with BAVs, TAVs have similar VSS values, but much smaller WSS and turbulence levels. These increased turbulence  and WSS levels in BAVs may play a key role in amplifying the biological responses of the ascending aorta wall and valvular leaflets, and support the hemodynamic underpinnings of BAV disease processes.

  7. A patient-specific aortic valve model based on moving resistive immersed implicit surfaces.

    PubMed

    Fedele, Marco; Faggiano, Elena; Dedè, Luca; Quarteroni, Alfio

    2017-10-01

    In this paper, we propose a full computational framework to simulate the hemodynamics in the aorta including the valve. Closed and open valve surfaces, as well as the lumen aorta, are reconstructed directly from medical images using new ad hoc algorithms, allowing a patient-specific simulation. The fluid dynamics problem that accounts from the movement of the valve is solved by a new 3D-0D fluid-structure interaction model in which the valve surface is implicitly represented through level set functions, yielding, in the Navier-Stokes equations, a resistive penalization term enforcing the blood to adhere to the valve leaflets. The dynamics of the valve between its closed and open position is modeled using a reduced geometric 0D model. At the discrete level, a finite element formulation is used and the SUPG stabilization is extended to include the resistive term in the Navier-Stokes equations. Then, after time discretization, the 3D fluid and 0D valve models are coupled through a staggered approach. This computational framework, applied to a patient-specific geometry and data, allows to simulate the movement of the valve, the sharp pressure jump occurring across the leaflets, and the blood flow pattern inside the aorta.

  8. Leaflet embolisation from Duromedics valves: a report of two cases.

    PubMed

    Kumar, N; Balasundaram, S; Rickard, M; al Halees, Z; Duran, C M

    1991-12-01

    Embolization of parts of mechanical valves has been reported since the inception of prosthetic valve implantation. We report here two cases of embolization of one hemileaflet of a Duromedic bileaflet prosthesis in the mitral position due to a pivot fracture. Both presented with moderately severe mitral regurgitation and pulmonary edema and were successfully managed by replacement of the malfunctioning prostheses. The embolised disc was located in the left common iliac artery by abdominal ultrasound and removed by an inguinal, retroperitoneal approach with low morbidity. Both patients left hospital and are doing well to-date.

  9. Topography of aortic heart valves. [applied to the development of a prosthetic heart valve

    NASA Technical Reports Server (NTRS)

    Karara, H. M.

    1974-01-01

    The cooperative effort towards the development of a tri-leaflet prosthetic heart valve is described. The photogrammetric studies were conducted on silicone rubber molds. Information on data acquisition and data reduction phases is given, and certain accuracy aspects of the project are explained. The various outputs which are discussed include digital models, profiles, and contour maps.

  10. Computational Modeling of Blood Flow and Valve Dynamics in Hearts with Hypertrophic Cardiomyopathy

    NASA Astrophysics Data System (ADS)

    Zheng, Xudong; Mittal, Rajat; Abraham, Theodore; Pinheiro, Aurelio

    2010-11-01

    Hypertrophic Cardiomyopathy (HCM) is a cardiovascular disease manifested by the thickening of the ventricular wall and often leads to a partial obstruction to the blood flow out of the left ventricle. HCM is recognized as one of the most common causes of sudden cardiac death in athletes. In a heart with HCM, the hypertrophy usually narrows the blood flow pathway to the aorta and produces a low pressure zone between the mitral valve and the hypertrophy during systole. This low pressure can suck the mitral valve leaflet back and completely block the blood flow into the aorta. In the current study, a sharp interface immersed boundary method flow solver is employed to study the hemodynamics and valve dynamics inside a heart with HCM. The three-dimensional motion and configuration of the left ventricle including mitral valve leaflets and aortic valves are reconstructed based on echo-cardio data sets. The mechanisms of aortic obstruction associated with HCM are investigated. The long term objective of this study is to develop a computational tool to aid in the assessment and surgical management of HCM.

  11. Successful treatment of pure aortic insufficiency with transapical implantation of the JenaValve.

    PubMed

    Bleiziffer, Sabine; Mazzitelli, Domenico; Nöbauer, Christian; Ried, Thomas; Lange, Rüdiger

    2013-08-01

    Transcatheter aortic valve implantation was predominantly developed for patients with severe calcified aortic stenosis, as most devices are designed to anchor within the native valve calcium. We report on a patient with pure insufficiency of a non-calcified aortic valve, in whom an anatomically oriented catheter valve was implanted successfully. The design of the prosthesis with position feelers engaging the native aortic valve leaflets proved to be suitable for the treatment of pure aortic insufficiency. Georg Thieme Verlag KG Stuttgart · New York.

  12. Application of simple biomechanical and biochemical tests to heart valve leaflets: implications for heart valve characterization and tissue engineering.

    PubMed

    Huang, Hsiao-Ying S; Balhouse, Brittany N; Huang, Siyao

    2012-11-01

    A simple biomechanical test with real-time displacement and strain mapping is reported, which provides displacement vectors and principal strain directions during the mechanical characterization of heart valve tissues. The maps reported in the current study allow us to quickly identify the approximate strain imposed on a location in the samples. The biomechanical results show that the aortic valves exhibit stronger anisotropic mechanical behavior than that of the pulmonary valves before 18% strain equibiaxial stretching. In contrast, the pulmonary valves exhibit stronger anisotropic mechanical behavior than aortic valves beyond 28% strain equibiaxial stretching. Simple biochemical tests are also conducted. Collagens are extracted at different time points (24, 48, 72, and 120 h) at different locations in the samples. The results show that extraction time plays an important role in determining collagen concentration, in which a minimum of 72 h of extraction is required to obtain saturated collagen concentration. This work provides an easy approach for quantifying biomechanical and biochemical properties of semilunar heart valve tissues, and potentially facilitates the development of tissue engineered heart valves.

  13. In vivo evaluation of an in-body, tissue-engineered, completely autologous valved conduit (biovalve type VI) as an aortic valve in a goat model.

    PubMed

    Takewa, Yoshiaki; Yamanami, Masashi; Kishimoto, Yuichiro; Arakawa, Mamoru; Kanda, Keiichi; Matsui, Yuichi; Oie, Tomonori; Ishibashi-Ueda, Hatsue; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Nakayama, Yasuhide

    2013-06-01

    Using simple, safe, and economical in-body tissue engineering, autologous valved conduits (biovalves) with the sinus of Valsalva and without any artificial support materials were developed in animal recipients' bodies. In this study, the feasibility of the biovalve as an aortic valve was evaluated in a goat model. Biovalves were prepared by 2-month embedding of the molds, assembled using two types of specially designed plastic rods, in the dorsal subcutaneous spaces of goats. One rod had three projections, resembling the protrusions of the sinus of Valsalva. Completely autologous connective tissue biovalves (type VI) with three leaflets in the inner side of the conduit with the sinus of Valsalva were obtained after removing the molds from both terminals of the harvested implants with complete encapsulation. The biovalve leaflets had appropriate strength and elastic characteristics similar to those of native aortic valves; thus, a robust conduit was formed. Tight valvular coaptation and a sufficient open orifice area were observed in vitro. Biovalves (n = 3) were implanted in the specially designed apico-aortic bypass for 2 months as a pilot study. Postoperative echocardiography showed smooth movement of the leaflets with little regurgitation under systemic circulation (2.6 ± 1.1 l/min). α-SMA-positive cells appeared significantly with rich angiogenesis in the conduit and expanded toward the leaflet tip. At the sinus portions, marked elastic fibers were formed. The luminal surface was covered with thin pseudointima without thrombus formation. Completely autologous biovalves with robust and elastic characteristics satisfied the higher requirements of the systemic circulation in goats for 2 months with the potential for valvular tissue regeneration.

  14. Platelet activation through a Bi-leaflet mechanical heart valve

    NASA Astrophysics Data System (ADS)

    Hedayat, Mohammadali; Borazjani, Iman

    2016-11-01

    Platelet activation is one of the major drawbacks of the Mechanical Heart Valves (MHVs) which can increase the risk of thrombus formation in patients. The platelet activation in MHVs can be due to the abnormal shear stress during the systole, the backward leakage flow during the diastole, and the flow through the hinge region. We investigate the contribution of each of the above mechanism to the activation of platelets in MHVs by performing simulations of the flow through the MHV and in the hinge region. The large scale heart valve simulations are performed in a straight aorta using a sharp interface curvilinear immersed boundary method along with a strong-coupling algorithm under physiological flow conditions. In addition, in order to perform the simulation of hinge region the flow field boundary conditions are obtained from the largescale simulations during a whole cardiac cycle. In order to investigate the role of hinge flow on platelet activation in MHVs, a 23mm St. Jude Medical Regent valve hinge with three different gap sizes is tested along with different platelet activation models to ensure the consistency of our results with different activation models. We compare the platelet activation of the hinge region against the bulk of the flow during one cardiac cycle. This work is supported by the American Heart Association Grant 13SDG17220022, and the computational resources were partly provided by Center for Computational Research (CCR) at University at Buffalo.

  15. Intravalvular Implantation of Mitral Valve Prostheses

    PubMed Central

    Cooley, Denton A.; Ingram, Michael T.

    1987-01-01

    We describe a technique of intravalvular implantation of a low-profile prosthesis that has been used in nine patients with mitral valve lesions. This technique preserves the anterior and posterior chordae and papillary mechanisms, which may decrease the incidence of postoperative left ventricular dysfunction that has been noted following standard mitral valve replacement. The technique may also be useful in some patients with aortic and tricuspid regurgitation when the annulus and leaflets are relatively normal pathologically. (Texas Heart Institute Journal 1987;14:188-193) PMID:15229740

  16. Flow in prosthetic heart valves: state-of-the-art and future directions.

    PubMed

    Yoganathan, Ajit P; Chandran, K B; Sotiropoulos, Fotis

    2005-12-01

    Since the first successful implantation of a prosthetic heart valve four decades ago, over 50 different designs have been developed including both mechanical and bioprosthetic valves. Today, the most widely implanted design is the mechanical bileaflet, with over 170,000 implants worldwide each year. Several different mechanical valves are currently available and many of them have good bulk forward flow hemodynamics, with lower transvalvular pressure drops, larger effective orifice areas, and fewer regions of forward flow stasis than their earlier-generation counterparts such as the ball-and-cage and tilting-disc valves. However, mechanical valve implants suffer from complications resulting from thrombus deposition and patients implanted with these valves need to be under long-term anti-coagulant therapy. In general, blood thinners are not needed with bioprosthetic implants, but tissue valves suffer from structural failure with, an average life-time of 10-12 years, before replacement is needed. Flow-induced stresses on the formed elements in blood have been implicated in thrombus initiation within the mechanical valve prostheses. Regions of stress concentration on the leaflets during the complex motion of the leaflets have been implicated with structural failure of the leaflets with bioprosthetic valves. In vivo and in vitro experimental studies have yielded valuable information on the relationship between hemodynamic stresses and the problems associated with the implants. More recently, Computational Fluid Dynamics (CFD) has emerged as a promising tool, which, alongside experimentation, can yield insights of unprecedented detail into the hemodynamics of prosthetic heart valves. For CFD to realize its full potential, however, it must rely on numerical techniques that can handle the enormous geometrical complexities of prosthetic devices with spatial and temporal resolution sufficiently high to accurately capture all hemodynamically relevant scales of motion. Such

  17. Finite element analysis for edge-to-edge technique to treat post-mitral valve repair systolic anterior motion.

    PubMed

    Zhong, Qi; Zeng, Wenhua; Huang, Xiaoyang; Zhao, Xiaojia

    2014-01-01

    Systolic anterior motion of the mitral valve is an uncommon complication of mitral valve repair, which requires immediate supplementary surgical action. Edge-to-edge suture is considered as an effective technique to treat post-mitral valve repair systolic anterior motion by clinical researchers. However, the fundamentals and quantitative analysis are vacant to validate the effectiveness of the additional edge-to-edge surgery to repair systolic anterior motion. In the present work, finite element models were developed to simulate a specific clinical surgery for patients with posterior leaflet prolapse, so as to analyze the edge-to-edge technique quantificationally. The simulated surgery procedure concluded several actions such as quadrangular resection, mitral annuloplasty and edge-to-edge suture. And the simulated results were compared with echocardiography and measurement data of the patients under the mitral valve surgery, which shows good agreement. The leaflets model with additional edge-to-edge suture has a shorter mismatch length than that of the model merely under quadrangular resection and mitral annuloplasty actions at systole, which assures a better coaptation status. The stress on the leaflets after edge-to-edge suture is lessened as well.

  18. A biomimetic bi-leaflet mitral prosthesis with enhanced physiological left ventricular swirl restorative capability

    NASA Astrophysics Data System (ADS)

    Tan, Sean Guo-Dong; Kim, Sangho; Leo, Hwa Liang

    2016-06-01

    Mechanical heart valve prostheses are often implanted in young patients due to their durability and long-term reliability. However, existing designs are known to induce elevated levels of blood damage and blood platelet activation. As a result, there is a need for patients to undergo chronic anti-coagulation treatment to prevent thrombosis, often resulting in bleeding complications. Furthermore, recent studies have suggested that the implantation of a mechanical prosthetic valve at the mitral position results in a significant alteration of the left ventricular flow field which may contribute to flow turbulence. This study proposes a bi-leaflet mechanical heart valve design (Bio-MHV) that mimics the geometry of a human mitral valve, with the aim of reducing turbulence levels in the left ventricle by replicating physiological flow patterns. An in vitro three-dimensional particle velocimetry imaging experiment was carried out to compare the hemodynamic performance of the Bio-MHV with that of the clinically established ATS valve. The Bio-MHV was found to replicate physiological left ventricular flow patterns and produced lower turbulence levels.

  19. Characterization of Fluid Flow through a Simplified Heart Valve Model

    NASA Astrophysics Data System (ADS)

    Katija, Kakani

    2005-11-01

    Research has shown that the leading vortex of a starting jet makes a larger contribution to mass transport than a straight jet. Physical processes terminate growth of the leading vortex ring at a stroke ratio (L/D) between 3.5 and 4.5. This has enhanced the idea that biological systems optimize vortex formation for fluid transport. Of present interest is how fluid transport through a heart valve induces flutter of the valve leaflets. An attempt to characterize the fluid flow through a heart valve was made using a simplified cylinder-string system. Experiments were conducted in a water tank where a piston pushed fluid out of a cylinder (of diameter D) into surrounding fluid. A latex string was attached to the end of the cylinder to simulate a heart valve leaflet. The FFT of the string motion was computed to quantify the flutter behavior observed in the cylinder-string system. By increasing the stroke ratio, the amplitude of transverse oscillations for all string lengths increases. For the string length D/2, the occurrence of flutter coincides with the formation of the vortex ring trailing jet.

  20. Mitral valve repair using ePTFE sutures for ruptured mitral chordae tendineae: a computational simulation study.

    PubMed

    Rim, Yonghoon; Laing, Susan T; McPherson, David D; Kim, Hyunggun

    2014-01-01

    Mitral valve (MV) repair using expanded polytetrafluoroethylene sutures is an established and preferred interventional method to resolve the complex pathophysiologic problems associated with chordal rupture. We developed a novel computational evaluation protocol to determine the effect of the artificial sutures on restoring MV function following valve repair. A virtual MV was created using three-dimensional echocardiographic data in a patient with ruptured mitral chordae tendineae (RMCT). Virtual repairs were designed by adding artificial sutures between the papillary muscles and the posterior leaflet where the native chordae were ruptured. Dynamic finite element simulations were performed to evaluate pre- and post-repair MV function. Abnormal posterior leaflet prolapse and mitral regurgitation was clearly demonstrated in the MV with ruptured chordae. Following virtual repair to reconstruct ruptured chordae, the severity of the posterior leaflet prolapse decreased and stress concentration was markedly reduced both in the leaflet tissue and the intact native chordae. Complete leaflet coaptation was restored when four or six sutures were utilized. Computational simulations provided quantitative information of functional improvement following MV repair. This novel simulation strategy may provide a powerful tool for evaluation and prediction of interventional treatment for RMCT.

  1. Dysfunction of an On-X Heart Valve by Pannus.

    PubMed

    Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria

    2016-09-01

    A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.

  2. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    PubMed

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  3. 3D Bioprinting of Heterogeneous Aortic Valve Conduits with Alginate/Gelatin Hydrogels

    PubMed Central

    Duan, Bin; Hockaday, Laura A.; Kang, Kevin H.; Butcher, Jonathan T.

    2013-01-01

    Heart valve disease is a serious and growing public health problem for which prosthetic replacement is most commonly indicated. Current prosthetic devices are inadequate for younger adults and growing children. Tissue engineered living aortic valve conduits have potential for remodeling, regeneration, and growth, but fabricating natural anatomical complexity with cellular heterogeneity remain challenging. In the current study, we implement 3D bioprinting to fabricate living alginate/gelatin hydrogel valve conduits with anatomical architecture and direct incorporation of dual cell types in a regionally constrained manner. Encapsulated aortic root sinus smooth muscle cells (SMC) and aortic valve leaflet interstitial cells (VIC) were viable within alginate/gelatin hydrogel discs over 7 days in culture. Acellular 3D printed hydrogels exhibited reduced modulus, ultimate strength, and peak strain reducing slightly over 7-day culture, while the tensile biomechanics of cell-laden hydrogels were maintained. Aortic valve conduits were successfully bioprinted with direct encapsulation of SMC in the valve root and VIC in the leaflets. Both cell types were viable (81.4±3.4% for SMC and 83.2±4.0% for VIC) within 3D printed tissues. Encapsulated SMC expressed elevated alpha-smooth muscle actin when printed in stiff matrix, while VIC expressed elevated vimentin in soft matrix. These results demonstrate that anatomically complex, heterogeneously encapsulated aortic valve hydrogel conduits can be fabricated with 3D bioprinting. PMID:23015540

  4. Key facts. Leaflets.

    PubMed

    1998-01-01

    Leaflets about HIV/AIDS are useful for distributing after talks or counseling sessions, leaving out in settings such as clinics, and mailing out in response to frequently asked questions or inquiries about an organization's services. As is the case with other educational materials, leaflet production involves identification of a target audience, careful planning and pretesting, and attention to design principles. Leaflets can be produced more quickly when adapted from existing materials distributed by other programs. Presented in this article are instructions that should be given to writers, designers, illustrators, or photographers when work is commissioned as well as guidelines for communicating with printers.

  5. Impact of mitral valve geometry on hemodynamic efficacy of surgical repair in secondary mitral regurgitation.

    PubMed

    Padala, Muralidhar; Gyoneva, Lazarina I; Thourani, Vinod H; Yoganathan, Ajit P

    2014-01-01

    Mitral valve geometry is significantly altered secondary to left ventricular remodeling in non-ischemic and ischemic dilated cardiomyopathies. Since the extent of remodeling and asymmetry of dilatation of the ventricle differ significantly between individual patients, the valve geometry and tethering also differ. The study aim was to determine if mitral valve geometry has an impact on the efficacy of surgical repairs to eliminate regurgitation and restore valve closure in a validated experimental model. Porcine mitral valves (n = 8) were studied in a pulsatile heart simulator, in which the mitral valve geometry can be precisely altered and controlled throughout the experiment. Baseline hemodynamics for each valve were measured (Control), and the valves were tethered in two distinct ways: annular dilatation with 7 mm apical papillary muscle (PM) displacement (Tether 1, symmetric), and annular dilatation with 7 mm apical, 7 mm posterior and 7 mm lateral PM displacement (Tether 2, asymmetric). Mitral annuloplasty was performed on each valve (Annular Repair), succeeded by anterior leaflet secondary chordal cutting (Sub-annular Repair). The efficacy of each repair in the setting of a given valve geometry was quantified by measuring the changes in mitral regurgitation (MR), leaflet coaptation length, tethering height and area. At baseline, none of the valves was regurgitant. Significant leaflet tethering was measured in Tether 2 over Tether 1, but both groups were significantly higher compared to baseline (60.9 +/- 31 mm2 for Control versus 129.7 +/- 28.4 mm2 for Tether 1 versus 186.4 +/- 36.3 mm2 for Tether 2). Consequently, the MR fraction was higher in Tether 2 group (23.0 +/- 5.7%) than in Tether 1 (10.5 +/- 5.5%). Mitral annuloplasty reduced MR in both groups, but remnant regurgitation after the repair was higher in Tether 2. After chordal cutting a similar trend was observed with trace regurgitation in Tether 1 group at 3.6 +/- 2.8%, in comparison to 18.6 +/- 4

  6. Early Outcomes for Valve-in-valve Transcatheter Aortic Valve Replacement in Degenerative Freestyle Bioprostheses.

    PubMed

    Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William

    2017-11-20

    Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Integrating valve-inspired design features into poly(ethylene glycol) hydrogel scaffolds for heart valve tissue engineering.

    PubMed

    Zhang, Xing; Xu, Bin; Puperi, Daniel S; Yonezawa, Aline L; Wu, Yan; Tseng, Hubert; Cuchiara, Maude L; West, Jennifer L; Grande-Allen, K Jane

    2015-03-01

    The development of advanced scaffolds that recapitulate the anisotropic mechanical behavior and biological functions of the extracellular matrix in leaflets would be transformative for heart valve tissue engineering. In this study, anisotropic mechanical properties were established in poly(ethylene glycol) (PEG) hydrogels by crosslinking stripes of 3.4 kDa PEG diacrylate (PEGDA) within 20 kDa PEGDA base hydrogels using a photolithographic patterning method. Varying the stripe width and spacing resulted in a tensile elastic modulus parallel to the stripes that was 4.1-6.8 times greater than that in the perpendicular direction, comparable to the degree of anisotropy between the circumferential and radial orientations in native valve leaflets. Biomimetic PEG-peptide hydrogels were prepared by tethering the cell-adhesive peptide RGDS and incorporating the collagenase-degradable peptide PQ (GGGPQG↓IWGQGK) into the polymer network. The specific amounts of RGDS and PEG-PQ within the resulting hydrogels influenced the elongation, de novo extracellular matrix deposition and hydrogel degradation behavior of encapsulated valvular interstitial cells (VICs). In addition, the morphology and activation of VICs grown atop PEG hydrogels could be modulated by controlling the concentration or micro-patterning profile of PEG-RGDS. These results are promising for the fabrication of PEG-based hydrogels using anatomically and biologically inspired scaffold design features for heart valve tissue engineering. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  8. Kangaroo vs. porcine aortic valves: calcification potential after glutaraldehyde fixation.

    PubMed

    Narine, K; Chéry, Cyrille C; Goetghebeur, Els; Forsyth, R; Claeys, E; Cornelissen, Maria; Moens, L; Van Nooten, G

    2005-01-01

    The aim of this study was to evaluate and compare the calcification potential of kangaroo and porcine aortic valves after glutaraldehyde fixation at both low (0.6%) and high (2.0%) concentrations of glutaraldehyde in the rat subcutaneous model. To our knowledge this is the first report comparing the time-related, progressive calcification of these two species in the rat subcutaneous model. Twenty-two Sprague-Dawley rats were each implanted with two aortic valve leaflets (porcine and kangaroo) after fixation in 0.6% glutaraldehyde and two aortic valve leaflets (porcine and kangaroo) after fixation in 2% glutaraldehyde respectively. Animals were sacrificed after 24 h and thereafter weekly for up to 10 weeks after implantation. Calcium content was determined using inductively coupled plasma-mass spectrometry and confirmed histologically. Mean calcium content per milligram of tissue (dry weight) treated with 0.6 and 2% glutaraldehyde was 116.2 and 110.4 microg/mg tissue for kangaroo and 95.0 and 106.8 microg/mg tissue for porcine valves. Calcium content increased significantly over time (8.8 microg/mg tissue per week) and was not significantly different between groups. Regression analysis of calcification over time showed no significant difference in calcification of valves treated with 0.6 or 2% glutaraldehyde within and between the two species. Using the subcutaneous model, we did not detect a difference in calcification potential between kangaroo and porcine aortic valves treated with either high or low concentrations of glutaraldehyde. Copyright 2005 S. Karger AG, Basel.

  9. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    PubMed

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  10. Mitral valve morphology assessed by three-dimensional transthoracic echocardiography in healthy dogs and dogs with myxomatous mitral valve disease.

    PubMed

    Menciotti, G; Borgarelli, M; Aherne, M; Wesselowski, S; Häggström, J; Ljungvall, I; Lahmers, S M; Abbott, J A

    2017-04-01

    To assess differences in morphology of the mitral valve (MV) between healthy dogs and dogs affected by myxomatous mitral valve disease (MMVD) using real-time transthoracic three-dimensional echocardiography (RT3DE). Thirty-four were normal dogs and 79 dogs were affected by MMVD. Real-time transthoracic three-dimensional echocardiography mitral datasets were digitally recorded and analyzed using dedicated software. The following variables were obtained and compared between healthy dogs and dogs with MMVD at different stages: antero-posterior annulus diameter, anterolateral-posteromedial annulus diameter, commissural diameter, annulus height, annulus circumference, annulus area, anterior leaflet length, anterior leaflet area, posterior leaflet length, posterior leaflet area, non-planar angle, annulus sphericity index, tenting height, tenting area, tenting volume, the ratio of annulus height and commissural diameter. Dogs with MMVD had a more circular MV annulus compared to healthy dogs as demonstrated by an increased annulus sphericity index (p=0.0179). Affected dogs had a less saddle-shaped MV manifest as a decreased annulus height to commissural width ratio (p=0.0004). Tenting height (p<0.0001), area (p<0.0001), and volume (p<0.0001) were less in affected dogs. Real-time transthoracic three-dimensional echocardiography analysis demonstrated that dogs affected by MMVD had a more circular and less saddle-shaped MV annulus, as well as reduced tenting height area and volume, compared to healthy dogs. Multiple variables differed between dogs at different stages of MMVD. Diagnostic and prognostic utility of these variables, and the significance of these changes in the pathogenesis and natural history of MMVD, require further attention. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Computational analysis of an aortic valve jet

    NASA Astrophysics Data System (ADS)

    Shadden, Shawn C.; Astorino, Matteo; Gerbeau, Jean-Frédéric

    2009-11-01

    In this work we employ a coupled FSI scheme using an immersed boundary method to simulate flow through a realistic deformable, 3D aortic valve model. This data was used to compute Lagrangian coherent structures, which revealed flow separation from the valve leaflets during systole, and correspondingly, the boundary between the jet of ejected fluid and the regions of separated, recirculating flow. Advantages of computing LCS in multi-dimensional FSI models of the aortic valve are twofold. For one, the quality and effectiveness of existing clinical indices used to measure aortic jet size can be tested by taking advantage of the accurate measure of the jet area derived from LCS. Secondly, as an ultimate goal, a reliable computational framework for the assessment of the aortic valve stenosis could be developed.

  12. Decellularized heart valve as a scaffold for in vivo recellularization: deleterious effects of granulocyte colony-stimulating factor.

    PubMed

    Juthier, Francis; Vincentelli, André; Gaudric, Julien; Corseaux, Delphine; Fouquet, Olivier; Calet, Christine; Le Tourneau, Thierry; Soenen, Valérie; Zawadzki, Christophe; Fabre, Olivier; Susen, Sophie; Prat, Alain; Jude, Brigitte

    2006-04-01

    Autologous recellularization of decellularized heart valve scaffolds is a promising challenge in the field of tissue-engineered heart valves and could be boosted by bone marrow progenitor cell mobilization. The aim of this study was to examine the spontaneous in vivo recolonization potential of xenogeneic decellularized heart valves in a lamb model and the effects of granulocyte colony-stimulating factor mobilization of bone marrow cells on this process. Decellularized porcine aortic valves were implanted in 12 lambs. Six lambs received granulocyte colony-stimulating factor (10 microg x kg(-1) x d(-1) for 7 days, granulocyte colony-stimulating factor group), and 6 received no granulocyte colony-stimulating factor (control group). Additionally, nondecellularized porcine valves were implanted in 5 lambs (xenograft group). Angiographic and histologic evaluation was performed at 3, 6, 8, and 16 weeks. Few macroscopic modifications of leaflets and the aortic wall were observed in the control group, whereas progressive shrinkage and thickening of the leaflets appeared in the granulocyte colony-stimulating factor and xenograft groups. In the 3 groups progressive ovine cell infiltration (fluorescence in situ hybridization) was observed in the leaflets and in the adventitia and the intima of the aortic wall but not in the media. Neointimal proliferation of alpha-actin-positive cells, inflammatory infiltration, adventitial neovascularization, and calcifications were more important in the xenograft and the granulocyte colony-stimulating factor groups than in the control group. Continuous re-endothelialization appeared only in the control group. Decellularized xenogeneic heart valve scaffolds allowed partial autologous recellularization. Granulocyte colony-stimulating factor led to accelerated heart valve deterioration similar to that observed in nondecellularized xenogeneic cardiac bioprostheses.

  13. Mitral valve disease—morphology and mechanisms

    PubMed Central

    Levine, Robert A.; Hagége, Albert A.; Judge, Daniel P.; Padala, Muralidhar; Dal-Bianco, Jacob P.; Aikawa, Elena; Beaudoin, Jonathan; Bischoff, Joyce; Bouatia-Naji, Nabila; Bruneval, Patrick; Butcher, Jonathan T.; Carpentier, Alain; Chaput, Miguel; Chester, Adrian H.; Clusel, Catherine; Delling, Francesca N.; Dietz, Harry C.; Dina, Christian; Durst, Ronen; Fernandez-Friera, Leticia; Handschumacher, Mark D.; Jensen, Morten O.; Jeunemaitre, Xavier P.; Le Marec, Hervé; Le Tourneau, Thierry; Markwald, Roger R.; Mérot, Jean; Messas, Emmanuel; Milan, David P.; Neri, Tui; Norris, Russell A.; Peal, David; Perrocheau, Maelle; Probst, Vincent; Pucéat, Michael; Rosenthal, Nadia; Solis, Jorge; Schott, Jean-Jacques; Schwammenthal, Ehud; Slaugenhaupt, Susan A.; Song, Jae-Kwan; Yacoub, Magdi H.

    2016-01-01

    Mitral valve disease is a frequent cause of heart failure and death. Emerging evidence indicates that the mitral valve is not a passive structure, but—even in adult life—remains dynamic and accessible for treatment. This concept motivates efforts to reduce the clinical progression of mitral valve disease through early detection and modification of underlying mechanisms. Discoveries of genetic mutations causing mitral valve elongation and prolapse have revealed that growth factor signalling and cell migration pathways are regulated by structural molecules in ways that can be modified to limit progression from developmental defects to valve degeneration with clinical complications. Mitral valve enlargement can determine left ventricular outflow tract obstruction in hypertrophic cardiomyopathy, and might be stimulated by potentially modifiable biological valvular–ventricular interactions. Mitral valve plasticity also allows adaptive growth in response to ventricular remodelling. However, adverse cellular and mechanobiological processes create relative leaflet deficiency in the ischaemic setting, leading to mitral regurgitation with increased heart failure and mortality. Our approach, which bridges clinicians and basic scientists, enables the correlation of observed disease with cellular and molecular mechanisms, leading to the discovery of new opportunities for improving the natural history of mitral valve disease. PMID:26483167

  14. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    PubMed

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  15. In-body tissue-engineered aortic valve (Biovalve type VII) architecture based on 3D printer molding.

    PubMed

    Nakayama, Yasuhide; Takewa, Yoshiaki; Sumikura, Hirohito; Yamanami, Masashi; Matsui, Yuichi; Oie, Tomonori; Kishimoto, Yuichiro; Arakawa, Mamoru; Ohmuma, Kentaro; Tajikawa, Tsutomu; Kanda, Keiichi; Tatsumi, Eisuke

    2015-01-01

    In-body tissue architecture--a novel and practical regeneration medicine technology--can be used to prepare a completely autologous heart valve, based on the shape of a mold. In this study, a three-dimensional (3D) printer was used to produce the molds. A 3D printer can easily reproduce the 3D-shape and size of native heart valves within several processing hours. For a tri-leaflet, valved conduit with a sinus of Valsalva (Biovalve type VII), the mold was assembled using two conduit parts and three sinus parts produced by the 3D printer. Biovalves were generated from completely autologous connective tissue, containing collagen and fibroblasts, within 2 months following the subcutaneous embedding of the molds (success rate, 27/30). In vitro evaluation, using a pulsatile circulation circuit, showed excellent valvular function with a durability of at least 10 days. Interposed between two expanded polytetrafluoroethylene grafts, the Biovalves (N = 3) were implanted in goats through an apico-aortic bypass procedure. Postoperative echocardiography showed smooth movement of the leaflets with minimal regurgitation under systemic circulation. After 1 month of implantation, smooth white leaflets were observed with minimal thrombus formation. Functional, autologous, 3D-shaped heart valves with clinical application potential were formed following in-body embedding of specially designed molds that were created within several hours by 3D printer. © 2014 Wiley Periodicals, Inc.

  16. Fibrous composite material for textile heart valve design: in vitro assessment.

    PubMed

    Amri, Amna; Laroche, Gaetan; Chakfe, Nabil; Heim, Frederic

    2018-04-17

    With over 150,000 implantations performed over the world, transcatheter aortic valve replacement (TAVR) has become a surgical technique, which largely competes with open surgery valve replacement for an increasing number of patients. The success of the procedure favors the research toward synthetic valve leaflet materials as an alternative to biological tissues, whose durability remains unknown. In particular, fibrous constructions have recently proven to be durable in vivo over a 6-month period of time in animal sheep models. Exaggerated fibrotic tissue formation remains, however, a critical issue to be addressed. This work investigates the design of a composite fibrous construction combining a woven polyethylene terephthalate (PET) layer and a non-woven PET mat, which are expected to provide, respectively, strength and appropriate topography toward limited fibrotic tissue ingrowth. For this purpose, a specific equipment has been developed to produce non-woven PET mats made from fibers with small diameter. These mats were assembled with woven PET substrates using various assembling techniques in order to obtain hybrid fibrous constructions. The physical and mechanical properties of the obtained materials were assessed and valve samples were manufactured to be tested in vitro for hydrodynamic performances. The results show that the composite fibrous construction is characterized by properties suitable for the valve leaflet function, but the durability of the assembling is however limited under accelerated cyclic loading.

  17. Does Undersizing of Transcatheter Aortic Valve Bioprostheses during Valve-in-Valve Implantation Avoid Coronary Obstruction? An In Vitro Study.

    PubMed

    Stock, Sina; Scharfschwerdt, Michael; Meyer-Saraei, Roza; Richardt, Doreen; Charitos, Efstratios I; Sievers, Hans-Hinrich; Hanke, Thorsten

    2017-04-01

    Background  The transcatheter aortic valve-in-valve implantation (TAViVI) is an evolving treatment strategy for degenerated surgical aortic valve bioprostheses (SAVBs) in patients with high operative risk. Although hemodynamics is excellent, there is some concern regarding coronary obstruction, especially in SAVB with externally mounted leaflet tissue, such as the Trifecta (St. Jude Medical Inc., St. Paul, Minnesota, United States). We investigated coronary flow and hydrodynamics before and after TAViVI in a SAVB with externally mounted leaflet tissue (St. Jude Medical, Trifecta) with an undersized transcatheter aortic valve bioprosthesis (Edwards Sapien XT; Edwards Lifesciences LLC, Irvine, California, United States) in an in vitro study. Materials and Methods  An aortic root model was constructed incorporating geometric dimensions known as risk factors for coronary obstruction. Investigating the validity of this model, we primarily performed recommended TAViVI with the Sapien XT (size 26 mm) in a Trifecta (size 25 mm) in a mock circulation. Thereafter, hydrodynamic performance and coronary flow (left/right coronary diastolic flow [lCF/rCF]) after TAViVI with an undersized Sapien XT (size 23 mm) in a Trifecta (size 25 mm) were investigated at two different coronary ostia heights (COHs, 8 and 10 mm). Results  Validation of the model led to significant coronary obstruction ( p  < 0.001). Undersized TAViVI showed no significant reduction with respect to coronary flow (lCF: COH 8 mm, 0.90-0.87 mL/stroke; COH 10 mm, 0.89-0.82 mL/stroke and rCF: COH 8 mm, 0.64-0.60 mL/stroke; COH 10 mm, 0.62-0.58 mL/stroke). Mean transvalvular gradients (4-5 mm Hg, p  < 0.001) increased significantly after TAViVI. Conclusions  In our in vitro model, undersized TAViVI with the balloon-expandable Sapien XT into a modern generation SAVB (Trifecta) successfully avoided coronary flow obstruction. Georg Thieme Verlag KG Stuttgart · New York.

  18. A Novel Left Heart Simulator for the Multi-modality Characterization of Native Mitral Valve Geometry and Fluid Mechanics

    PubMed Central

    Rabbah, Jean-Pierre; Saikrishnan, Neelakantan; Yoganathan, Ajit P.

    2012-01-01

    Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental validation. As computational solvers vary considerably, experimental benchmark data are critically important to ensure model accuracy. In this study, a novel left heart simulator was designed specifically for the validation of numerical mitral valve models. Several distinct experimental techniques were collectively performed to resolve mitral valve geometry and hemodynamics. In particular, micro-computed tomography was used to obtain accurate and high-resolution (39 µm voxel) native valvular anatomy, which included the mitral leaflets, chordae tendinae, and papillary muscles. Threedimensional echocardiography was used to obtain systolic leaflet geometry for direct comparison of resultant leaflet kinematics. Stereoscopic digital particle image velocimetry provided all three components of fluid velocity through the mitral valve, resolved every 25 ms in the cardiac cycle. A strong central filling jet was observed during peak systole, with minimal out-of-plane velocities (V~0.6m/s). In addition, physiologic hemodynamic boundary conditions were defined and all data were synchronously acquired through a central trigger. Finally, the simulator is a precisely controlled environment, in which flow conditions and geometry can be systematically prescribed and resultant valvular function and hemodynamics assessed. Thus, these data represent the first comprehensive database of high fidelity experimental data, critical for extensive validation of mitral valve fluid structure interaction simulations. PMID:22965640

  19. Recycling of the pulmonary valve: an elegant solution for secondary pulmonary regurgitation in patients with tetralogy of Fallot.

    PubMed

    Prêtre, René; Rosser, Barbara; Mueller, Christoph; Kretschmar, Oliver; Dave, Hitendu

    2012-09-01

    The purpose of this study was to review our experience with recycling of the pulmonary valve in cases of chronic pulmonary insufficiency after a transannular patch procedure as part of a repair of tetralogy of Fallot. Eight patients in whom the technique was used were reviewed. Technically, the valve was reapproximated at the anterior commissure if the valve leaflet was sufficiently developed and of good tissue quality. Additional corrections were performed in 5 patients (resection of an infundibular aneurysm [5 patients], repair of the tricuspid valve [1 patient]). The valve was competent with no or trivial regurgitation in 5 patients and a small regurgitation in 3 patients. There was no significant transvalvular gradient in 5 patients with tricuspid valves and a small gradient in 3 patients with a bicuspid valves (<23 mm Hg). The valve function remained stable over the follow-up period (median time, 32 months). Recycling of the pulmonary valve is an interesting concept that could avoid the necessary reoperations linked with valves or valved prostheses. The repair must be carefully followed in bicuspid valves because of a reduction in the opening area. Valve leaflets of good quality should be preserved during the primary repair of tetralogy of Fallot and the transannular incision should be made across the anterior commissure if possible. These steps should allow a few patients to profit from a recycling of their valves in the future. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Mitral valve coaptation and its relationship to late diastolic flow: A color Doppler and vector flow map echocardiographic study in normal subjects.

    PubMed

    Sherrid, Mark V; Kushner, Josef; Yang, Georgiana; Ro, Richard

    2017-04-01

    Three competing theories about the mechanism of mitral coaptation in normal subjects were evaluated by color Doppler and vector flow mapping (VFM): (1) beginning of ventricular (LV) ejection, (2) "breaking of the jet" of diastolic LV inflow, and (3) returning diastolic vortices impacting the leaflets on their LV surfaces. We analyzed 80 color Doppler frames and 320 VFM measurements. In all 20 normal subjects, coaptation occurred before LV ejection, 78±16 ms before onset. On color Doppler frames the larger anterior, and smaller posterior vortices circle back and, in all cases, strike the ventricular surfaces of the leaflets. On the first closing-begins frame, for the first time, vortex velocity normal to the ventricular surface of the anterior leaflet (AML) is greater than that in the mitral orifice, and the angle of attack of LV vortical flow onto the AML is twice as high as the angle of flow onto the valve in orifice. Thus, at the moment coaptation begins, vortical flow strikes the mitral leaflet with higher velocity, and higher angle of attack than orifice flow, and thus with greater force. According to the "breaking of the jet" theory, one would expect to see de novo LV flow perpendicular to the leaflets beginning after transmitral flow terminates. Instead, the returning continuous LV vortical flow that impacts the valve builds continuously after the P-wave. Late diastolic vortices strike the ventricular surfaces of the mitral leaflets and contribute to valve coaptation, permitted by concomitant decline in transmitral flow. © 2017, Wiley Periodicals, Inc.

  1. A technique of snaring method for fitting a prosthetic valve into the annulus.

    PubMed

    Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki

    2005-01-01

    Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.

  2. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    PubMed Central

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  3. [Evaluation of a self-care leaflet].

    PubMed

    Lystad, N; Heian, F

    1989-01-20

    A self care leaflet of 50 pages was distributed in Tingvoll, a municipality with 3,500 inhabitants. The leaflet gives advice about self treatment and prevention of common health problems, and guidelines for contacting the health services. In surveys conducted just before and 10 months after the distribution, we documented -- how the leaflet was accepted and used --changes in knowledge about the health problems mentioned in the leaflet. The leaflet was well accepted. It was characterized as easy to read and to use. 10 months after distribution to read and to use. 10 months after distribution 90% found it within five minutes. 63% used the leaflet when they had a health problem. 90% of those using the leaflet felt more sure that they acted correctly after consulting it, and 60% changed their mind about consulting a general practitioner. We consider the level of knowledge about health problems to be low. The evaluation showed increased knowledge in all groups, except for persons "responsible for caring for elderly relatives". The increase was most marked for "men" and for "persons with health education".

  4. Annular dilatation and loss of sino-tubular junction in aneurysmatic aorta: implications on leaflet quality at the time of surgery. A finite element study†

    PubMed Central

    Weltert, Luca; de Tullio, Marco D.; Afferrante, Luciano; Salica, Andrea; Scaffa, Raffaele; Maselli, Daniele; Verzicco, Roberto; De Paulis, Ruggero

    2013-01-01

    OBJECTIVES In the belief that stress is the main determinant of leaflet quality deterioration, we sought to evaluate the effect of annular and/or sino-tubular junction dilatation on leaflet stress. A finite element computer-assisted stress analysis was used to model four different anatomic conditions and analyse the consequent stress pattern on the aortic valve. METHODS Theoretical models of four aortic root configurations (normal, with dilated annulus, with loss of sino-tubular junction and with both dilatation simultaneously) were created with computer-aided design technique. The pattern of stress and strain was then analysed by means of finite elements analysis, when a uniform pressure of 100 mmHg was applied to the model. Analysis produced von Mises charts (colour-coded, computational, three-dimensional stress-pattern graphics) and bidimensional plots of compared stress on arc-linear line, which allowed direct comparison of stress in the four different conditions. RESULTS Stresses both on the free margin and on the ‘belly’ of the leaflet rose from 0.28 MPa (normal conditions) to 0.32 MPa (+14%) in case of isolated dilatation of the sino-tubular junction, while increased to 0.42 MPa (+67%) in case of isolated annular dilatation, with no substantial difference whether sino-tubular junction dilatation was present or not. CONCLUSIONS Annular dilatation is the key element determining an increased stress on aortic leaflets independently from an associated sino-tubular junction dilatation. The presence of annular dilatation associated with root aneurysm greatly decreases the chance of performing a valve sparing procedure without the need for additional manoeuvres on leaflet tissue. This information may lead to a refinement in the optimal surgical strategy. PMID:23536020

  5. Acquired discrete subaortic stenosis late after mitral valve replacement.

    PubMed

    Mohan, Jagdish C; Shukla, Madhu; Mohan, Vishwas; Sethi, Arvind

    2016-09-01

    Although acquired left ventricular outflow obstruction has been reported in a variety of conditions, there are scant reports of its occurrence following mitral valve replacement (MVR). This study describes two female patients, who developed severe discrete subaortic stenosis, five years following MVR. In both cases, the mitral valve was replaced by a porcine Carpentier-Edwards 27-mm bioprosthesis with preservation of mitral valve leaflets. The risk of very late left ventricular outflow tract obstruction after bio-prosthetic MVR with preservation of subvalvular apparatus needs to be kept in mind in symptomatic patients. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  6. Prosthetic Tricuspid Valve Thrombosis: Three Case Reports and Literature Review

    PubMed Central

    Yaminisharif, Ahmad; Alemzadeh-Ansari, Mohammad Javad; Ahmadi, Seyed Hossein

    2012-01-01

    A common complication of prosthetic heart valves is thrombosis. Although the incidence of prosthetic valve thrombosis (PVT) in the tricuspid position is high, there are not enough data on the management of it, in contrast to left-sided PVT. Here, we describe three cases of tricuspid PVT with three different management approaches: thrombolytic therapy; close observation with oral anticoagulants; and surgery. The first case was a woman who suffered from recurrent PVT, for which we successfully used Tenecteplase for second and third episodes. We employed Tenecteplase in this case for the first time in the therapy of tricuspid PVT. The second case had fixed leaflets in open position while being symptomless. At six months' follow-up, with the patient having taken oral anticoagulants, the motion of the leaflets was restricted and she was symptomfree. The last case was a woman who had a large thrombus in the right atrium immediately after mitral and tricuspid valvular replacement. The patient underwent re-replacement surgery and a new biological valve was implanted in the tricuspid position. Also, we review the literature on the pathology, signs and symptoms, diagnosis, and management of tricuspid PVT. PMID:23323074

  7. In vivo canine studies of a Sinkhole valve and vascular graft coated with biocompatible PU-PEO-SO3.

    PubMed

    Han, D K; Lee, K B; Park, K D; Kim, C S; Jeong, S Y; Kim, Y H; Kim, H M; Min, B G

    1993-01-01

    PU-PEO-SO3 was applied as a coating material over a newly designed Sinkhole bileaflet PU heart valve and a porous PU vascular graft. Performance and biocompatibility were evaluated using an in vivo canine shunt system between the right ventricle and pulmonary artery. The survival periods in three implantations were 14, 24, and 39 days, during which no mechanical failure occurred in any Sinkhole valve or vascular graft. Scanning electron microscopy (SEM) studies demonstrated much less platelet adhesion and thrombus formation on PU-PEO-SO3 grafts than on PU vascular grafts. Cracks in the valve leaflet were occasionally observed on PU surfaces, but not on PU-PEO-SO3. After a 39 day implantation, calcium deposition on vascular grafts was decreased as compared with valve leaflets, and calcification on PU-PEO-SO3 was much lower than on PU. These results suggest that Sinkhole valves and vascular grafts are promising, and PU-PEO-SO3 as a coating material is more blood compatible, biostable, and calcification resistant in vivo than in untreated PU.

  8. Mitral Valve Chordae Tendineae: Topological and Geometrical Characterization.

    PubMed

    Khalighi, Amir H; Drach, Andrew; Bloodworth, Charles H; Pierce, Eric L; Yoganathan, Ajit P; Gorman, Robert C; Gorman, Joseph H; Sacks, Michael S

    2017-02-01

    Mitral valve (MV) closure depends upon the proper function of each component of the valve apparatus, which includes the annulus, leaflets, and chordae tendineae (CT). Geometry plays a major role in MV mechanics and thus highly impacts the accuracy of computational models simulating MV function and repair. While the physiological geometry of the leaflets and annulus have been previously investigated, little effort has been made to quantitatively and objectively describe CT geometry. The CT constitute a fibrous tendon-like structure projecting from the papillary muscles (PMs) to the leaflets, thereby evenly distributing the loads placed on the MV during closure. Because CT play a major role in determining the shape and stress state of the MV as a whole, their geometry must be well characterized. In the present work, a novel and comprehensive investigation of MV CT geometry was performed to more fully quantify CT anatomy. In vitro micro-tomography 3D images of ovine MVs were acquired, segmented, then analyzed using a curve-skeleton transform. The resulting data was used to construct B-spline geometric representations of the CT structures, enriched with a continuous field of cross-sectional area (CSA) data. Next, Reeb graph models were developed to analyze overall topological patterns, along with dimensional attributes such as segment lengths, 3D orientations, and CSA. Reeb graph results revealed that the topology of ovine MV CT followed a full binary tree structure. Moreover, individual chords are mostly planar geometries that together form a 3D load-bearing support for the MV leaflets. We further demonstrated that, unlike flow-based branching patterns, while individual CT branches became thinner as they propagated further away from the PM heads towards the leaflets, the total CSA almost doubled. Overall, our findings indicate a certain level of regularity in structure, and suggest that population-based MV CT geometric models can be generated to improve current MV

  9. Feasibility of Valve-in-Valve Procedure for Degenerated St. Jude Medical Trifecta Bioprosthesis.

    PubMed

    Verhoye, Jean-philippe; Harmouche, Majid; Soulami, Reda Belhaj; Thebault, Christophe; Boulmier, Dominique; Leguerrier, Alain; Anselmi, Amedeo

    2015-07-01

    The valve-in-valve (ViV) procedure is an option for patients with symptomatic structural degeneration of a bioprosthesis and excessive reoperative risk. The risk of coronary obstruction appears to be increased if ViV is performed for certain pericardial prostheses in which the leaflets are mounted outside the stent posts. Herein is described a successful ViV for a degenerated Trifecta aortic bioprosthesis, and the technical considerations for performing a ViV procedure within such types of prosthesis are considered. Emphasis is placed on the importance of preoperative investigations (computed tomography scan-based measurements of coronary ostial height and of sinus of Valsalva diameters), and on the precise deployment of the valve (transapical approach with transesophageal echocardiography control) to minimize the risk of major complications. The presence of a failing Trifecta bioprosthesis should not be considered an absolute contraindication to ViV on the basis of the risk of coronary obstruction.

  10. A global perspective on mechanical prosthetic heart valve thrombosis: Diagnostic and therapeutic challenges

    PubMed Central

    Gürsoy, Mustafa Ozan; Kalçık, Macit; Yesin, Mahmut; Karakoyun, Süleyman; Bayam, Emrah; Gündüz, Sabahattin; Özkan, Mehmet

    2016-01-01

    Prosthetic valve thrombosis is one of the major causes of primary valve failure, which can be life-threatening. Multimodality imaging is necessary for determination of leaflet immobilization, cause of underlying pathology (thrombus versus pannus or both), and whether thrombolytic therapy attempt in the patient would be successful or surgery is needed. Current guidelines for the management of prosthetic valve thrombosis lack definitive class I recommendations due to lack of randomized controlled trials, and usually leave the choice of treatment to the clinician’s experience. In this review, we aimed to summarize the pathogenesis, diagnosis, and management of mechanical prosthetic valve thrombosis. PMID:28005024

  11. Mechanism of valve failure and efficacy of reintervention through catheterization in patients with bioprosthetic valves in the pulmonary position

    PubMed Central

    Callahan, Ryan; Bergersen, Lisa; Baird, Christopher W; Porras, Diego; Esch, Jesse J; Lock, James E; Marshall, Audrey C

    2017-01-01

    Background: Surgical and transcatheter bioprosthetic valves (BPVs) in the pulmonary position in patients with congenital heart disease may ultimately fail and undergo transcatheter reintervention. Angiographic assessment of the mechanism of BPV failure has not been previously described. Aims: The aim of this study was to determine the mode of BPV failure (stenosis/regurgitation) requiring transcatheter reintervention and to describe the angiographic characteristics of the failed BPVs and report the types and efficacy of reinterventions. Materials and Methods: This is a retrospective single-center review of consecutive patients who previously underwent pulmonary BPV placement (surgical or transcatheter) and subsequently underwent percutaneous reintervention from 2005 to 2014. Results: Fifty-five patients with surgical (41) and transcutaneous pulmonary valve (TPV) (14) implantation of BPVs underwent 66 catheter reinterventions. The surgically implanted valves underwent fifty reinterventions for indications including 16 for stenosis, seven for regurgitation, and 27 for both, predominantly associated with leaflet immobility, calcification, and thickening. Among TPVs, pulmonary stenosis (PS) was the exclusive failure mode, mainly due to loss of stent integrity (10) and endocarditis (4). Following reintervention, there was a reduction of right ventricular outflow tract gradient from 43 ± 16 mmHg to 16 ± 10 mmHg (P < 0.001) and RVp/AO ratio from 0.8 ± 0.2 to 0.5 ± 0.2 (P < 0.001). Reintervention with TPV placement was performed in 45 (82%) patients (34 surgical, 11 transcatheter) with no significant postintervention regurgitation or paravalvular leak. Conclusion: Failing surgically implanted BPVs demonstrate leaflet calcification, thickness, and immobility leading to PS and/or regurgitation while the mechanism of TPV failure in the short- to mid-term is stenosis, mainly from loss of stent integrity. This can be effectively treated with a catheter-based approach

  12. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    PubMed

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  13. Durability of hand-sewn valves in the right ventricular outlet.

    PubMed

    Nunn, Graham R; Bennetts, Jayme; Onikul, Ella

    2008-08-01

    The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained

  14. The angiotensin II type 1 receptor blocker losartan attenuates bioprosthetic valve leaflet calcification in a rabbit intravascular implant model.

    PubMed

    Shin, Hong Ju; Kim, Dae-Hyun; Park, Han Ki; Park, Young Hwan

    2016-12-01

    There is evidence that angiotensin II type I receptor blocker (ARB) could reduce structural valve deterioration. However, the anticalcification effect on the bioprosthetic heart valve (BHV) has not been investigated. Thus, we investigated the effects of losartan (an ARB) on calcification of implanted bovine pericardial tissue in a rabbit intravascular implant model. A total of 16 male New Zealand White rabbits (20 weeks old, 2.98-3.34 kg) were used in this study. Commercially available BHV leaflet of bovine pericardium was trimmed to the shape of a 3-mm triangle and implanted to both external jugular veins of the rabbit. The ARB group (n = 8) was given 25 mg/kg of powdered losartan daily until 6 weeks after surgery by direct administration in the buccal pouch of the animals. The control group (n = 8) was given 5 ml of normal saline by the same method. After 6 weeks, quantitative calcium determination, histological evaluation and western blot analysis of interleukin-6 (IL-6), osteopontin and bone morphogenetic protein 2 (BMP-2) were performed to investigate the mechanisms of the anticalcification effect of losartan. No deaths or complications such as infection or haematoma were recorded during the experiment. All animals were euthanized on the planned date. The calcium measurement level in the ARB group (2.28 ± 0.65 mg/g) was significantly lower than that in the control group (3.68 ± 1.00 mg/g) (P = 0.0092). Immunohistochemistry analyses revealed that BMP-2-positive reactions were significantly attenuated in the ARB group. Western blot analysis showed that losartan suppressed the expression of IL-6, osteopontin and BMP-2. Our results indicate that losartan significantly attenuates postimplant degenerative calcification of a bovine pericardial bioprosthesis in a rabbit intravascular implant model. Further studies are required to assess the effects of ARBs on BHV tissue in orthotopic implantations using a large animal model. © The Author 2016. Published by Oxford

  15. PN FOR CHILDREN - INFORMATION LEAFLET.

    PubMed

    Riddell, Rebecca; Lewis, Anthony; Tuthill, David

    2016-09-01

    To produce a leaflet for parents and carers of children receiving parenteral nutrition (PN) explaining:▸ What PN is▸ Why it is given▸ How it will be given▸ Risks & Complications▸ Other useful information▸ Nutrition team contact informationCurrent practice is for the nutrition team pharmacist to give a verbal account of the above information to parents/carers. It was felt that providing this information in a written format would introduce consisitency and allow parents/carers more time to take information on board. An internet search and discussions with other organisations with paediatric gastroenterology specialists was conduted to see if something similar was in existence. A similar information leaflet to what we hoped to produce was not found. Members of the paediatric nutrition team, which included consultants, nurse specialists, pharmacist and dietician, provided input to the type of information that should be included in the information leaflet. A first draft of the leaflet was produced and shown to the parents of current paediatric PN inpatients. Feedback was received and the leaflet updated following consultation with the nutrition team. Production of a very useful information leaflet for parents/carers, containing all the relevant information and detail. The leaflet uses colour and pictures to aid the transfer of information and makes it more attractive to read. The pharmacist is the main point of contact for the paediatric nutrition team and will be the individual responsible for distributing them. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Percutaneous bioprosthetic venous valve: a long-term study in sheep.

    PubMed

    Pavcnik, Dusan; Uchida, Barry T; Timmermans, Hans A; Corless, Christopher L; O'Hara, Michael; Toyota, Naoyuki; Moneta, Gregory L; Keller, Frederick S; Rösch, Josef

    2002-03-01

    A long-term evaluation of a new percutaneously placed bioprosthetic, bicuspid venous valve (BVV) consisting of a square stent and small intestinal submucosa (SIS) covering was performed in 12 sheep. Of 26 BVVs placed into the jugular veins, 25 exhibited good valve function on immediate venography and 22 on venograms obtained before the sheep were killed. Gross and histologic examination results demonstrated incorporation of remodeled and endothelialized SIS BVVs into the vein wall. Slight to moderate leaflet thickening was found mostly at their bases. Percutaneously placed SIS BVV is a promising one-way, competent valve that resists venous back-pressure while allowing forward flow.

  17. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    PubMed

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  18. The mechanobiology of mitral valve function, degeneration, and repair

    PubMed Central

    Richards, Jennifer M.; Farrar, Emily J.; Kornreich, Bruce G.; Moïse, N. Sydney; Butcher, Jonathan T.

    2013-01-01

    In degenerative valve disease, the highly organized mitral valve leaflet matrix stratification is progressively destroyed and replaced with proteoglycan rich, mechanically inadequate tissue. This is driven by the actions of originally quiescent valve interstitial cells that become active contractile and migratory myofibroblasts. While treatment for myxomatous mitral valve disease in humans ranges from repair to total replacement, therapies in dogs focus on treating the consequences of the resulting mitral regurgitation. The fundamental gap in our understanding is how the resident valve cells respond to altered mechanical signals to drive tissue remodeling. Despite the pathological similarities and high clinical occurrence, surprisingly little mechanistic insight has been gleaned from the dog. This review presents what is known about mitral valve mechanobiology from clinical, in vivo, and in vitro data. There are a number of experimental strategies already available to pursue this significant opportunity, but success requires the collaboration between veterinary clinicians, scientists, and engineers. PMID:22366572

  19. Repair of Tricuspid Valve Leaflet With CardioCel Patch After Traumatic Tricuspid Regurgitation.

    PubMed

    Konstantinidou, Maria Kalliopi; Moat, Neil

    2017-09-01

    Posttraumatic tricuspid valve regurgitation (TR) is a rare entity and is almost always associated with blunt chest trauma. It is usually identified by transthoracic echocardiography after the manifestation of clinical symptoms of heart failure. Treatment varies from long-term medical therapy and observation to surgical correction with tricuspid valve replacement or repair. We describe the case of a 26-year-old man who was involved in a major road traffic accident and was referred for surgical repair a year later because of severe posttraumatic TR. The tricuspid valve was successfully reconstructed with a CardioCel patch, Gore-Tex neochordae, and a tricuspid ring. The patient recovered well. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Flail tricuspid valve secondary to blunt chest trauma

    PubMed Central

    Srinivas, Sunil Kumar; Patil, Shivanand; Ramalingam, Rangaraj; Bhairappa, Shivakumar

    2012-01-01

    A 78-year-old man admitted with complaints of breathlessness of 1 year and typical chest pain of 2 months duration. He had a blunt chest trauma 7 years back. Transthoracic echocardiography revealed severe tricuspid regurgitation due to a flail anterior leaflet of the tricuspid valve. It also revealed global left ventricular dysfunction. Flail tricuspid valve causing severe regurgitation is usually due to mechanical trauma. Since it is well tolerated for years, the diagnosis may be delayed or missed entirely. Echocardiography has allowed easier diagnosis of this condition resulting in earlier and, hence, more effective treatment. PMID:22922931

  1. Clinical significance of incomplete tricuspid valve closure seen on two-dimensional echocardiography.

    PubMed

    Gibson, T C; Foale, R A; Guyer, D E; Weyman, A E

    1984-11-01

    Incomplete closure of the tricuspid valve without apparent cusp disease was noted on two-dimensional echocardiography in 31 patients. This abnormality was defined as a failure of the tricuspid valve leaflet tips to reach the plane of the tricuspid valve anulus by at least 1 cm in the standard apical four chamber view at the point of maximal systolic closure. This resulted in a final systolic leaflet position deeper within the right ventricular cavity than is normally seen. The finding was present in the following diagnostic subgroups: Group A, pulmonary hypertension (11 patients); Group B, rheumatic heart disease (4 patients); Group C, dilated cardiomyopathy (9 patients) and Group D, previous myocardial infarction (7 patients). Right atrial, right ventricular and tricuspid anulus measurements were made and compared with those from a group of 67 normal subjects. The results were as follows: right atrial endsystolic area = 27.2 +/- 8.6 cm2 (normal = 13.4 +/- 2.0); right ventricular end-systolic area = 25.6 +/- 8.7 cm2 (normal = 10.9 +/- 2.9); right ventricular end-diastolic area = 31.5 +/- 9.1 cm2 (normal = 20.1 +/- 4.9) and tricuspid valve anular end-systolic dimension = 4.0 +/- 0.6 cm (normal = 2.2 +/- 0.3). The differences from the normal data were all statistically significant (p less than 0.001). Incomplete closure of the tricuspid valve, although a nonspecific diagnostic finding, is primarily associated with right-sided chamber enlargement. Tricuspid regurgitation may be present. The mechanism could be related to geometric changes in valve apparatus dynamics secondary to right-sided cardiac enlargement and tricuspid valve anular dilation.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. The dynamic cardiac biosimulator: A method for training physicians in beating-heart mitral valve repair procedures.

    PubMed

    Leopaldi, Alberto M; Wrobel, Krzysztof; Speziali, Giovanni; van Tuijl, Sjoerd; Drasutiene, Agne; Chitwood, W Randolph

    2018-01-01

    Previously, cardiac surgeons and cardiologists learned to operate new clinical devices for the first time in the operating room or catheterization laboratory. We describe a biosimulator that recapitulates normal heart valve physiology with associated real-time hemodynamic performance. To highlight the advantages of this simulation platform, transventricular extruded polytetrafluoroethylene artificial chordae were attached to repair flail or prolapsing mitral valve leaflets. Guidance for key repair steps was by 2-dimensional/3-dimensional echocardiography and simultaneous intracardiac videoscopy. Multiple surgeons have assessed the use of this biosimulator during artificial chordae implantations. This simulation platform recapitulates normal and pathologic mitral valve function with associated hemodynamic changes. Clinical situations were replicated in the simulator and echocardiography was used for navigation, followed by videoscopic confirmation. This beating heart biosimulator reproduces prolapsing mitral leaflet pathology. It may be the ideal platform for surgeon and cardiologist training on many transcatheter and beating heart procedures. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.

  3. Collagen organization in canine myxomatous mitral valve disease: an x-ray diffraction study.

    PubMed

    Hadian, Mojtaba; Corcoran, Brendan M; Han, Richard I; Grossmann, J Günter; Bradshaw, Jeremy P

    2007-10-01

    Collagen fibrils, a major component of mitral valve leaflets, play an important role in defining shape and providing mechanical strength and flexibility. Histopathological studies show that collagen fibrils undergo dramatic changes in the course of myxomatous mitral valve disease in both dogs and humans. However, little is known about the detailed organization of collagen in this disease. This study was designed to analyze and compare collagen fibril organization in healthy and lesional areas of myxomatous mitral valves of dogs, using synchrotron small-angle x-ray diffraction. The orientation, density, and alignment of collagen fibrils were mapped across six different valves. The findings reveal a preferred collagen alignment in the main body of the leaflets between two commissures. Qualitative and quantitative analysis of the data showed significant differences between affected and lesion-free areas in terms of collagen content, fibril alignment, and total tissue volume. Regression analysis of the amount of collagen compared to the total tissue content at each point revealed a significant relationship between these two parameters in lesion-free but not in affected areas. This is the first time this technique has been used to map collagen fibrils in cardiac tissue; the findings have important applications to human cardiology.

  4. Increased frequency of mitral valve prolapse in patients with deviated nasal septum.

    PubMed

    Arslan, Hasan Huseyin; Aparci, Mustafa; Arslan, Zekeriya; Ozturk, Cengiz; Isilak, Zafer; Balta, Sevket; Celik, Turgay; Iyisoy, Atila

    2015-07-01

    Any abnormality of collagen may affect the tissues with higher collagen content, e.g., joints, heart valves, and great arteries. Mitral valve prolapse (MVP) is a characteristic of generalized collagen abnormality. Nasal septum (NS) is constituted by osseous and cartilaginous septums that are highly rich in collagen. We evaluated the co-existence of deviation of NS (DNS) in patients with MVP. We retrospectively evaluated the recordings of echocardiographic and nasal examinations of subjects with MVP and DNS. We analyzed the features of MVP and anatomical classification of DNS among subjects. Totally, 74 patients with DNS and 38 subjects with normal nasal passage were enrolled to the study. Presence of MVP was significantly higher in patients with DNS compared to normal subjects (63 vs 26%, p < 0.001). Prolapse of anterior, posterior and both leaflets was higher in patients with DNS. Thickness of anterior mitral leaflet was significantly increased in patients with DNS (3.57 ± 0.68 vs 4.59 ± 1.1 mm, p < 0.001) compared to normal subjects. Type I, II, and III, IV DNS were higher in frequency in patients with MVP while type V and VI were higher in normal subjects. DNS is highly co-existent with MVP and increased thickness of mitral anterior leaflet. Generalized abnormality of collagen which is the main component of mitral valves and nasal septum may be accounted for co-existence of MVP and DNS. Also co-existence of them may exaggerate the symptoms of patients with MVP due to limited airflow through the nasal passage.

  5. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    PubMed

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Diffusion in phospholipid bilayer membranes: dual-leaflet dynamics and the roles of tracer–leaflet and inter-leaflet coupling

    PubMed Central

    Hill, Reghan J.; Wang, Chih-Ying

    2014-01-01

    A variety of observations—sometimes controversial—have been made in recent decades when attempting to elucidate the roles of interfacial slip on tracer diffusion in phospholipid membranes. Evans–Sackmann theory (1988) has furnished membrane viscosities and lubrication-film thicknesses for supported membranes from experimentally measured lateral diffusion coefficients. Similar to the Saffman and Delbrück model, which is the well-known counterpart for freely supported membranes, the bilayer is modelled as a single two-dimensional fluid. However, the Evans–Sackman model cannot interpret the mobilities of monotopic tracers, such as individual lipids or rigidly bound lipid assemblies; neither does it account for tracer–leaflet and inter-leaflet slip. To address these limitations, we solve the model of Wang and Hill, in which two leaflets of a bilayer membrane, a circular tracer and supports are coupled by interfacial friction, using phenomenological friction/slip coefficients. This furnishes an exact solution that can be readily adopted to interpret the mobilities of a variety of mosaic elements—including lipids, integral monotopic and polytopic proteins, and lipid rafts—in supported bilayer membranes. PMID:25002822

  7. Pros and cons of transcatheter aortic valve implantation (TAVI).

    PubMed

    Terré, Juan A; George, Isaac; Smith, Craig R

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.

  8. Fluid Dynamics of Thrombosis in Transcatheter Aortic Valves

    NASA Astrophysics Data System (ADS)

    Seo, Jung Hee; Zhu, Chi; Dou, Zhongwang; Resar, Jon; Mittal, Rajat

    2017-11-01

    Transcatheter aortic valve replacement (TAVR) with bioprosthetic valves (BPV) has become highly prevalent in recent years. While one advantage of BPVs over mechanical ones is the lower incidence of valve thrombosis, recent clinical studies have suggested a higher than expected incidence of subclinical bioprosthetic valve thrombosis (BVT). Many factors that might affect the transvalvular hemodynamics including the valve position, orientation, stent, and interaction with the coronary flow, have been suggested, but the casual mechanisms of valve thrombosis are still unknown. In the present study, the hemodynamics associated with the formation of BVT is investigated using a novel, coupled flow-structure-biochemical computational modeling. A reduced degree of freedom, fluid-structure-interaction model is proposed for the efficient simulation of the hemodynamics and leaflet dynamics in the BPVs. Simple models to take into account the effects of the stent and coronary flows have also been developed. Simulations are performed for canonical models of BPVs in the aorta in various configurations and the results are examined to provide insights into the mechanisms for valve thrombosis. Supported by the NSF Grants IIS-1344772, CBET-1511200 and NSF XSEDE Grant TG-CTS100002.

  9. Effect of Losartan on Mitral Valve Changes After Myocardial Infarction.

    PubMed

    Bartko, Philipp E; Dal-Bianco, Jacob P; Guerrero, J Luis; Beaudoin, Jonathan; Szymanski, Catherine; Kim, Dae-Hee; Seybolt, Margo M; Handschumacher, Mark D; Sullivan, Suzanne; Garcia, Michael L; Titus, James S; Wylie-Sears, Jill; Irvin, Whitney S; Messas, Emmanuel; Hagège, Albert A; Carpentier, Alain; Aikawa, Elena; Bischoff, Joyce; Levine, Robert A

    2017-09-05

    After myocardial infarction (MI), mitral valve (MV) tethering stimulates adaptive leaflet growth, but counterproductive leaflet thickening and fibrosis augment mitral regurgitation (MR), doubling heart failure and mortality. MV fibrosis post-MI is associated with excessive endothelial-to-mesenchymal transition (EMT), driven by transforming growth factor (TGF)-β overexpression. In vitro, losartan-mediated TGF-β inhibition reduces EMT of MV endothelial cells. This study tested the hypothesis that profibrotic MV changes post-MI are therapeutically accessible, specifically by losartan-mediated TGF-β inhibition. The study assessed 17 sheep, including 6 sham-operated control animals and 11 with apical MI and papillary muscle retraction short of producing MR; 6 of the 11 were treated with daily losartan, and 5 were untreated, with flexible epicardial mesh comparably limiting left ventricular (LV) remodeling. LV volumes, tethering, and MV area were quantified by using three-dimensional echocardiography at baseline and at 60 ± 6 days, and excised leaflets were analyzed by histopathology and flow cytometry. Post-MI LV dilation and tethering were comparable in the losartan-treated and untreated LV constraint sheep. Telemetered sensors (n = 6) showed no significant losartan-induced changes in arterial pressure. Losartan strongly reduced leaflet thickness (0.9 ± 0.2 mm vs. 1.6 ± 0.2 mm; p < 0.05; 0.4 ± 0.1 mm sham animals), TGF-β, and downstream phosphorylated extracellular-signal-regulated kinase and EMT (27.2 ± 12.0% vs. 51.6 ± 11.7% α-smooth muscle actin-positive endothelial cells, p < 0.05; 7.2 ± 3.5% sham animals), cellular proliferation, collagen deposition, endothelial cell activation (vascular cell adhesion molecule-1 expression), neovascularization, and cells positive for cluster of differentiation (CD) 45, a hematopoietic marker associated with post-MI valve fibrosis. Leaflet area increased comparably (17%) in constrained and losartan

  10. Live 3D TEE demonstrates and guides the management of prosthetic mitral valve obstruction.

    PubMed

    Chahal, Mangeet; Pandya, Utpal; Adlakha, Satjit; Khouri, Samer J

    2011-08-01

    A 43-year-old woman, with a remote history of rheumatic mitral stenosis and a St. Jude prosthetic mitral valve replacement, presented with shortness of breath and palpitations, shortly after a long flight. On admission, atrial fibrillation with a rapid ventricular response was noted in the setting of a long history of noncompliance with her anticoagulation. Transesophageal echocardiography (TEE) demonstrated multiple laminated thrombi in the left atrial appendage. Live three-dimensional (3D) TEE confirmed this diagnosis and demonstrated an immobile posterior leaflet of the mitral prosthesis, which had direct implications in her management. She successfully underwent surgery for mitral valve replacement, left atrial appendage ligation, and a Maze procedure on the following day. The multiple thrombi within the atrial appendage were confirmed intraoperatively and pannus formation was determined to be the etiology of the leaflet immobility. © 2011, Wiley Periodicals, Inc.

  11. Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance

    PubMed Central

    Soares, Joao S.; Feaver, Kristen R.; Zhang, Will; Kamensky, David; Aggarwal, Ankush; Sacks, Michael S.

    2017-01-01

    The use of replacement heart valves continues to grow due to the increased prevalence of valvular heart disease resulting from an ageing population. Since bioprosthetic heart valves (BHVs) continue to be the preferred replacement valve, there continues to be a strong need to develop better and more reliable BHVs through and improved the general understanding of BHV failure mechanisms. The major technological hurdle for the lifespan of the BHV implant continues to be the durability of the constituent leaflet biomaterials, which if improved can lead to substantial clinical impact. In order to develop improved solutions for BHV biomaterials, it is critical to have a better understanding of the inherent biomechanical behaviors of the leaflet biomaterials, including chemical treatment technologies, the impact of repetitive mechanical loading, and the inherent failure modes. This review seeks to provide a comprehensive overview of these issues, with a focus on developing insight on the mechanisms of BHV function and failure. Additionally, this review provides a detailed summary of the computational biomechanical simulations that have been used to inform and develop a higher level of understanding of BHV tissues and their failure modes. Collectively, this information should serve as a tool not only to infer reliable and dependable prosthesis function, but also to instigate and facilitate the design of future bioprosthetic valves and clinically impact cardiology. PMID:27507280

  12. In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE).

    PubMed

    Rahmani, Benyamin; Tzamtzis, Spyros; Sheridan, Rose; Mullen, Michael J; Yap, John; Seifalian, Alexander M; Burriesci, Gaetano

    2017-04-01

    This study presents the in vitro hydrodynamic assessment of the TRISKELE, a new system suitable for transcatheter aortic valve implantation (TAVI), aiming to mitigate the procedural challenges experienced with current technologies. The TRISKELE valve comprises three polymeric leaflet and an adaptive sealing cuff, supported by a novel fully retrievable self-expanding nitinol wire frame. Valve prototypes were manufactured in three sizes of 23, 26, and 29 mm by automated dip-coating of a biostable polymer, and tested in a hydrodynamic bench setup in mock aortic roots of 21, 23, 25, and 27 mm annulus, and compared to two reference valves suitable for equivalent implantation ranges: Edwards SAPIEN XT and Medtronic CoreValve. The TRISKELE valves demonstrated a global hydrodynamic performance comparable or superior to the controls with significant reduction in paravalvular leakage. The TRISKELE valve exhibits enhanced anchoring and improved sealing. The valve is currently under preclinical investigation.

  13. Multiplanar visualization in 3D transthoracic echocardiography for precise delineation of mitral valve pathology.

    PubMed

    Kuppahally, Suman S; Paloma, Allan; Craig Miller, D; Schnittger, Ingela; Liang, David

    2008-01-01

    A novel multiplanar reformatting (MPR) technique in three-dimensional transthoracic echocardiography (3D TTE) was used to precisely localize the prolapsed lateral segment of posterior mitral valve leaflet in a patient symptomatic with mitral valve prolapse (MVP) and moderate mitral regurgitation (MR) before undergoing mitral valve repair surgery. Transesophageal echocardiography was avoided based on the findings of this new technique by 3D TTE. It was noninvasive, quick, reproducible and reliable. Also, it did not need the time-consuming reconstruction of multiple cardiac images. Mitral valve repair surgery was subsequently performed based on the MPR findings and corroborated the findings from the MPR examination.

  14. A finite element model on effects of impact load and cavitation on fatigue crack propagation in mechanical bileaflet aortic heart valve.

    PubMed

    Mohammadi, H; Klassen, R J; Wan, W-K

    2008-10-01

    Pyrolytic carbon mechanical heart valves (MHVs) are widely used to replace dysfunctional and failed heart valves. As the human heart beats around 40 million times per year, fatigue is the prime mechanism of mechanical failure. In this study, a finite element approach is implemented to develop a model for fatigue analysis of MHVs due to the impact force between the leaflet and the stent and cavitation in the aortic position. A two-step method to predict crack propagation in the leaflets of MHVs has been developed. Stress intensity factors (SIFs) are computed at a small initiated crack located on the leaflet edge (the worst case) using the boundary element method (BEM). Static analysis of the crack is performed to analyse the stress distribution around the front crack zone when the crack is opened; this is followed by a dynamic crack analysis to consider crack propagation using the finite element approach. Two factors are taken into account in the calculation of the SIFs: first, the effect of microjet formation due to cavitation in the vicinity of leaflets, resulting in water hammer pressure; second, the effect of the impact force between the leaflet and the stent of the MHVs, both in the closing phase. The critical initial crack length, the SIFs, the water hammer pressure, and the maximum jet velocity due to cavitation have been calculated. With an initial crack length of 35 microm, the fatigue life of the heart valve is greater than 60 years (i.e. about 2.2 x 10(9) cycles) and, with an initial crack length of 170 microm, the fatigue life of the heart valve would be around 2.5 years (i.e. about 9.1 x 10(7) cycles). For an initial crack length greater than 170 microm, there is catastrophic failure and fatigue cracking no longer occurs. A finite element model of fatigue analysis using Patran command language (PCL custom code) in MSC software can be used to evaluate the useful lifespan of MHVs. Similar methodologies can be extended to other medical devices under cyclic

  15. Leaflet Area as a Determinant of Tricuspid Regurgitation Severity in Patients with Pulmonary Hypertension

    PubMed Central

    Afilalo, Jonathan; Grapsa, Julia; Nihoyannopoulos, Petros; Beaudoin, Jonathan; Gibbs, J. Simon R.; Channick, Richard N.; Langleben, David; Rudski, Lawrence G.; Hua, Lanqi; Handschumacher, Mark D.; Picard, Michael H.; Levine, Robert A.

    2015-01-01

    Background Tricuspid regurgitation (TR) is a risk factor for mortality in pulmonary hypertension (PH). TR severity varies among patients with comparable degrees of PH and right ventricular (RV) remodeling. The contribution of leaflet adaptation to the pathophysiology of TR has yet to be examined. We hypothesized that tricuspid leaflet area (TLA) is increased in PH, and that its size relative to RV remodeling determines TR severity. Methods and Results A prospective cohort of 255 patients with PH from pre- and post-capillary etiologies was assembled from two centers. Patients underwent a 3-D echocardiogram focused on the tricuspid apparatus. TLA was measured with the Omni custom software package. Compared with normal controls, PH patients had a twofold increase in RV volumes, 62% increase in annulus area, and 49% increase in TLA. Those with severe TR demonstrated inadequate increase in TLA relative to the closure area, such that the ratio of TLA-to-closure area <1.78 was highly predictive of severe TR (odds ratio 68.7; 95% CI 16.2, 292.7). The median vena contracta width was 8.5 mm in the group with small TLA and large closure area as opposed to 4.8 mm in the group with large TLA and large closure area. Conclusions TLA plays a significant role in determining which patients with PH develop severe functional TR. The ratio of TLA-to-closure area, reflecting the balance between leaflet adaptation vs. annular dilation and tethering forces, is an indicator of TR severity that may identify which patients stand to benefit from leaflet augmentation during tricuspid valve repair. PMID:25977303

  16. Leaflet area as a determinant of tricuspid regurgitation severity in patients with pulmonary hypertension.

    PubMed

    Afilalo, Jonathan; Grapsa, Julia; Nihoyannopoulos, Petros; Beaudoin, Jonathan; Gibbs, J Simon R; Channick, Richard N; Langleben, David; Rudski, Lawrence G; Hua, Lanqi; Handschumacher, Mark D; Picard, Michael H; Levine, Robert A

    2015-05-01

    Tricuspid regurgitation (TR) is a risk factor for mortality in pulmonary hypertension (PH). TR severity varies among patients with comparable degrees of PH and right ventricular remodeling. The contribution of leaflet adaptation to the pathophysiology of TR has yet to be examined. We hypothesized that tricuspid leaflet area (TLA) is increased in PH, and that the adequacy of this increase relative to right ventricular remodeling determines TR severity. A prospective cohort of 255 patients with PH from pre and postcapillary pathogeneses was assembled from 2 centers. Patients underwent a 3-dimensional echocardiogram focused on the tricuspid apparatus. TLA was measured with the Omni 4D software package. Compared with normal controls, patients with PH had a 2-fold increase in right ventricular volumes, 62% increase in annular area, and 49% increase in TLA. Those with severe TR demonstrated inadequate increase in TLA relative to the closure area, such that the ratio of TLA:closure area <1.78 was highly predictive of severe TR (odds ratio, 68.7; 95% confidence interval, 16.2-292.7). The median vena contracta width was 8.5 mm in the group with small TLA and large closure area as opposed to 4.8 mm in the group with large TLA and large closure area. TLA plays a significant role in determining which patients with PH develop severe functional TR. The ratio of TLA:closure area, reflecting the balance between leaflet adaptation versus annular dilation and tethering forces, is an indicator of TR severity that may identify which patients stand to benefit from leaflet augmentation during tricuspid valve repair. © 2015 American Heart Association, Inc.

  17. Haemodynamic improvement of older, previously replaced mechanical mitral valves by removal of the subvalvular pannus in redo cardiac surgery.

    PubMed

    Kim, Jong Hun; Kim, Tae Youn; Choi, Jong Bum; Kuh, Ja Hong

    2017-01-01

    Patients requiring redo cardiac surgery for diseased heart valves other than mitral valves may show increased pressure gradients and reduced valve areas of previously placed mechanical mitral valves due to subvalvular pannus formation. We treated four women who had mechanical mitral valves inserted greater than or equal to 20 years earlier and who presented with circular pannus that protruded into the lower margin of the valve ring but did not impede leaflet motion. Pannus removal improved the haemodynamic function of the mitral valve. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Flail Tricuspid Valve in an Adult Patient with Congenitally Corrected Transposition of the Great Arteries.

    PubMed

    Meloni, Luigi; Abbruzzese, Piero A.; Pirisi, Raimondo; Cherchi, Angelo

    1997-01-01

    We describe a case of a 50-year-old woman with congenitally corrected transposition of the great vessels, in whom severe left-sided tricuspid (systemic atrioventricular) valve insufficiency was the only associated anomaly. The tricuspid valve was dysplastic and abnormally oriented toward the interventricular septum, without the downward displacement of Ebstein's anomaly. The mechanism of atrioventricular regurgitation was unusual in that it consisted of the rupture of chordae tendineae of both the anterior and septal leaflets. The left-sided tricuspid valve was replaced with a St. Jude prosthesis and the postoperative course was uneventful.

  19. Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study.

    PubMed

    Sturla, Francesco; Ronzoni, Mattia; Vitali, Mattia; Dimasi, Annalisa; Vismara, Riccardo; Preston-Maher, Georgia; Burriesci, Gaetano; Votta, Emiliano; Redaelli, Alberto

    2016-08-16

    Transcatheter aortic valve implantation (TAVI) can treat symptomatic patients with calcific aortic stenosis. However, the severity and distribution of the calcification of valve leaflets can impair the TAVI efficacy. Here we tackle this issue from a biomechanical standpoint, by finite element simulation of a widely adopted balloon-expandable TAVI in three models representing the aortic root with different scenarios of calcific aortic stenosis. We developed a modeling approach realistically accounting for aortic root pressurization and complex anatomy, detailed calcification patterns, and for the actual stent deployment through balloon-expansion. Numerical results highlighted the dependency on the specific calcification pattern of the "dog-boning" of the stent. Also, local stent distortions were associated with leaflet calcifications, and led to localized gaps between the TAVI stent and the aortic tissues, with potential implications in terms of paravalvular leakage. High stresses were found on calcium deposits, which may be a risk factor for stroke; their magnitude and the extent of the affected regions substantially increased for the case of an "arc-shaped" calcification, running from commissure to commissure. Moreover, high stresses due to the interaction between the aortic wall and the leaflet calcifications were computed in the annular region, suggesting an increased risk for annular damage. Our analyses suggest a relation between the alteration of the stresses in the native anatomical components and prosthetic implant with the presence and distribution of relevant calcifications. This alteration is dependent on the patient-specific features of the calcific aortic stenosis and may be a relevant indicator of suboptimal TAVI results. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Deletion of CD73 in mice leads to aortic valve dysfunction.

    PubMed

    Zukowska, P; Kutryb-Zajac, B; Jasztal, A; Toczek, M; Zabielska, M; Borkowski, T; Khalpey, Z; Smolenski, R T; Slominska, E M

    2017-06-01

    Aortic stenosis is known to involve inflammation and thrombosis. Changes in activity of extracellular enzyme - ecto-5'-nucleotidase (referred also as CD73) can alter inflammatory and thrombotic responses. This study aimed to evaluate the effect of CD73 deletion in mice on development of aortic valve dysfunction and to compare it to the effect of high-fat diet. Four groups of mice (normal-diet Wild Type (WT), high-fat diet WT, normal diet CD73-/-, high-fat diet CD73-/-) were maintained for 15weeks followed by echocardiographic analysis of aortic valve function, measurement of aortic surface activities of nucleotide catabolism enzymes as well as alkaline phosphatase activity, mineral composition and histology of aortic valve leaflets. CD73-/- knock out led to an increase in peak aortic flow (1.06±0.26m/s) compared to WT (0.79±0.26m/s) indicating obstruction. Highest values of peak aortic flow (1.26±0.31m/s) were observed in high-fat diet CD73-/- mice. Histological analysis showed morphological changes in CD73-/- including thickening and accumulation of dark deposits, proved to be melanin. Concentrations of Ca 2+ , Mg 2+ and PO 4 3- in valve leaflets were elevated in CD73-/- mice. Alkaline phosphatase (ALP) activity was enhanced after ATP treatment and reduced after adenosine treatment in aortas incubated in osteogenic medium. AMP hydrolysis in CD73-/- was below 10% of WT. Activity of ecto-adenosine deaminase (eADA), responsible for adenosine deamination, in the CD73-/- was 40% lower when compared to WT. Deletion of CD73 in mice leads to aortic valve dysfunction similar to that induced by high-fat diet suggesting important role of this surface protein in maintaining heart valve integrity. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    PubMed

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  2. The readability and suitability of sexual health promotion leaflets.

    PubMed

    Corcoran, Nova; Ahmad, Fatuma

    2016-02-01

    To investigate the readability and suitability of sexual health promotion leaflets. Application of SMOG, FRY and SAM tests to assess the readability and suitability of a selection of sexual health leaflets. SMOG and FRY scores illustrate an average reading level of grade 9. SAM scores indicate that 59% of leaflets are superior in design and 41% are average in design. Leaflets generally perform well in the categories of content, literacy demand, typography and layout. They perform poorly in use of graphics, learning stimulation/motivation and cultural appropriateness. Sexual health leaflets have a reading level that is too high. Leaflets perform well on the suitability scores indicating they are reasonably suitable. There are a number of areas where sexual health leaflets could improve their design. Numerous practical techniques are suggested for improving the readability and suitability of sexual health leaflets. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Pros and cons of transcatheter aortic valve implantation (TAVI)

    PubMed Central

    Terré, Juan A.; George, Isaac

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement. PMID:29062739

  4. Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

    PubMed

    El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A

    2018-01-23

    Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.

  5. Apoptosis in fresh and cryopreserved cardiac valves of pig samples.

    PubMed

    Rendal Vázquez, M Esther; Díaz Román, T M; Rodríguez Cabarcos, M; Zavanella Botta, C; Domenech García, N; González Cuesta, M; Sánchez Dopico, M J; Pértega Díaz, S; Andión Núñez, C

    2008-06-01

    To analyse the influence of cold ischemic time (CIT) (2-24 h) and of cryopreservation (liquid phase) on the viability of the valvular fibroblasts and in the presence of apoptosis. Cardiac valves from 10 pigs were evaluated by anatomo-pathological study of the wall, muscle and leaflet. At the same time, the presence of cellular death due to apoptosis was investigated in two ways; directly on tissue by Apodetec system and by two-colour flow cytometry assay analyzing a suspension of fibroblast from valve leaflets using Anexina V and propidium iodure (PI). We established three groups of samples to compare different experimental conditions: 2 h of ischemia (group 1), 24 h of ischemia (group 2), and a programme of cryopreservation (-1 degrees C/min) after 2 h of ischemia, followed by storage in liquid nitrogen during a week and thawing was performed (group 3). The analysis of viabilities showed slight differences between all three groups. The results indicated CIT of 24 h undergoing more structural affectation than CIT of 2 h. Flow cytometry analysis did not show important differences between groups; however cryopreserved samples (group 3) slightly less viability and a higher percentage of death by apoptosis than group 1 and 2 using flow cytometry. Apoptosis was confirmed on tissue from all valves but mainly in samples of group 2 and group 3. In summary, the viability of the valves in the case of ischemic times of 2 h, 24 h or after cryopreservation/thawing differs slightly. The death of the cells is mainly mediated by necrosis and not by apoptosis.

  6. Prenatally fabricated autologous human living heart valves based on amniotic fluid derived progenitor cells as single cell source.

    PubMed

    Schmidt, Dörthe; Achermann, Josef; Odermatt, Bernhard; Breymann, Christian; Mol, Anita; Genoni, Michele; Zund, Gregor; Hoerstrup, Simon P

    2007-09-11

    A novel concept providing prenatally tissue engineered human autologous heart valves based on routinely obtained fetal amniotic fluid progenitors as single cell source is introduced. Fetal human amniotic progenitors were isolated from routinely sampled amniotic fluid and sorted using CD133 magnetic beads. After expansion and differentiation, cell phenotypes of CD133- and CD133+ cells were analyzed by immunohistochemistry and flowcytometry. After characterization, CD133- derived cells were seeded onto heart valve leaflet scaffolds (n=18) fabricated from rapidly biodegradable polymers, conditioned in a pulse duplicator system, and subsequently coated with CD133+ derived cells. After in vitro maturation, opening and closing behavior of leaflets was investigated. Neo-tissues were analyzed by histology, immunohistochemistry, and scanning electron microscopy (SEM). Extracellular matrix (ECM) elements and cell numbers were quantified biochemically. Mechanical properties were assessed by tensile testing. CD133- derived cells demonstrated characteristics of mesenchymal progenitors expressing CD44 and CD105. Differentiated CD133+ cells showed features of functional endothelial cells by eNOS and CD141 expression. Engineered heart valve leaflets demonstrated endothelialized tissue formation with production of ECM elements (GAG 80%, HYP 5%, cell number 100% of native values). SEM showed intact endothelial surfaces. Opening and closing behavior was sufficient under half of systemic conditions. The use of amniotic fluid as single cell source is a promising low-risk approach enabling the prenatal fabrication of heart valves ready to use at birth. These living replacements with the potential of growth, remodeling, and regeneration may realize the early repair of congenital malformations.

  7. Technical pitfalls and tips for the valve-in-valve procedure

    PubMed Central

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these

  8. A repositionable valved stent for endovascular treatment of deteriorated bioprostheses.

    PubMed

    Zegdi, Rachid; Khabbaz, Ziad; Borenstein, Nicolas; Fabiani, Jean-Noël

    2006-10-03

    We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. Five sheep underwent, on beating heart, tricuspid VR with a stented BP. Prolapse of 1 leaflet was induced by tearing. For the endovascular tricuspid VR, we used a VS constructed with a nitinol self-expandable stent and a porcine stentless aortic valve. We also used an original delivery catheter, allowing repositioning of the VS through a compression or relaxation mechanism of the stent. Epicardial echocardiography and right ventriculography showed severe tricuspid regurgitation, with a regurgitant jet extending to the inferior vena cava. After surgical exposure to the infrarenal inferior vena cava, the VS was successfully implanted inside the failed BP in all cases. Repositioning of the fully deployed VS was always possible. Echocardiographic and macroscopic studies revealed adequate VS positioning, excellent leaflet opening, and absence of any intraprosthetic or periprosthetic leak. Endovascular VR was easily performed in sheep with failed BP in the tricuspid position. The novel delivery catheter allowed adequate repositioning of our fully deployed VS before its definitive release. One may anticipate that the safety improvement conferred by this new technology will certainly favor the development of percutaneous VR in clinical practice.

  9. Living nano-micro fibrous woven fabric/hydrogel composite scaffolds for heart valve engineering.

    PubMed

    Wu, Shaohua; Duan, Bin; Qin, Xiaohong; Butcher, Jonathan T

    2017-03-15

    Regeneration and repair of injured or diseased heart valves remains a clinical challenge. Tissue engineering provides a promising treatment approach to facilitate living heart valve repair and regeneration. Three-dimensional (3D) biomimetic scaffolds that possess heterogeneous and anisotropic features that approximate those of native heart valve tissue are beneficial to the successful in vitro development of tissue engineered heart valves (TEHV). Here we report the development and characterization of a novel composite scaffold consisting of nano- and micro-scale fibrous woven fabrics and 3D hydrogels by using textile techniques combined with bioactive hydrogel formation. Embedded nano-micro fibrous scaffolds within hydrogel enhanced mechanical strength and physical structural anisotropy of the composite scaffold (similar to native aortic valve leaflets) and also reduced its compaction. We determined that the composite scaffolds supported the growth of human aortic valve interstitial cells (HAVIC), balanced the remodeling of heart valve ECM against shrinkage, and maintained better physiological fibroblastic phenotype in both normal and diseased HAVIC over single materials. These fabricated composite scaffolds enable the engineering of a living heart valve graft with improved anisotropic structure and tissue biomechanics important for maintaining valve cell phenotypes. Heart valve-related disease is an important clinical problem, with over 300,000 surgical repairs performed annually. Tissue engineering offers a promising strategy for heart valve repair and regeneration. In this study, we developed and tissue engineered living nano-micro fibrous woven fabric/hydrogel composite scaffolds by using textile technique combined with bioactive hydrogel formation. The novelty of our technique is that the composite scaffolds can mimic physical structure anisotropy and the mechanical strength of natural aortic valve leaflet. Moreover, the composite scaffolds prevented the

  10. Artificial chordae for degenerative mitral valve disease: critical analysis of current techniques

    PubMed Central

    Ibrahim, Michael; Rao, Christopher; Athanasiou, Thanos

    2012-01-01

    The surgical repair of degenerative mitral valve disease involves a number of technical points of importance. The use of artificial chordae for the repair of degenerative disease has increased as a part of the move from mitral valve replacement to repair of the mitral valve. The use of artificial chordae provides an alternative to the techniques pioneered by Carpentier (including the quadrangular resection, transfer of native chordae and papillary muscle shortening/plasty), which can be more technically difficult. Despite a growth in their uptake and the indications for their use, a number of challenges remain for the use of artificial chordae in mitral valve repair, particularly in the determination of the correct length to ensure optimal leaflet coaptation. Here, we analyse over 40 techniques described for artificial chordae mitral valve repair in the setting of degenerative disease. PMID:22962321

  11. Estimation of aortic valve leaflets from 3D CT images using local shape dictionaries and linear coding

    NASA Astrophysics Data System (ADS)

    Liang, Liang; Martin, Caitlin; Wang, Qian; Sun, Wei; Duncan, James

    2016-03-01

    Aortic valve (AV) disease is a significant cause of morbidity and mortality. The preferred treatment modality for severe AV disease is surgical resection and replacement of the native valve with either a mechanical or tissue prosthetic. In order to develop effective and long-lasting treatment methods, computational analyses, e.g., structural finite element (FE) and computational fluid dynamic simulations, are very effective for studying valve biomechanics. These computational analyses are based on mesh models of the aortic valve, which are usually constructed from 3D CT images though many hours of manual annotation, and therefore an automatic valve shape reconstruction method is desired. In this paper, we present a method for estimating the aortic valve shape from 3D cardiac CT images, which is represented by triangle meshes. We propose a pipeline for aortic valve shape estimation which includes novel algorithms for building local shape dictionaries and for building landmark detectors and curve detectors using local shape dictionaries. The method is evaluated on real patient image dataset using a leave-one-out approach and achieves an average accuracy of 0.69 mm. The work will facilitate automatic patient-specific computational modeling of the aortic valve.

  12. Calcification of the mitral valve and annulus: systematic evaluation of effects on valve anatomy and function.

    PubMed

    Movva, Rajesh; Murthy, Kinnari; Romero-Corral, Abel; Seetha Rammohan, Harish Raj; Fumo, Peter; Pressman, Gregg S

    2013-10-01

    Mitral annular calcification (MAC) is common in chronic kidney disease. It is associated with cardiovascular events and can cause valvular dysfunction, but it has not been systematically characterized. The aim of this prospective study was to assess the prevalence and distribution of MAC, its effects on leaflet motion, and its association with mitral stenosis and mitral regurgitation (MR) in a hemodialysis population. Echocardiograms were obtained in 75 consecutive hemodialysis outpatients. MAC extent and distribution were graded semiquantitatively using two-dimensional and three-dimensional echocardiography. Associations with the presence and severity of mitral stenosis and MR were explored. The mean age was 60 ± 14 years; 60% were men, and 87% were African American. MAC was present in 64% (moderate to severe in 48%). Calcium extended more than halfway onto the leaflet in 37% and beyond the annulus in 40%. Leaflet motion was restricted in 37%. Mitral stenosis was present in 28%, and the extent of calcification was associated with mean mitral valve gradient (P < .0001). MR was prevalent (present in 81%) but was severe in none. The severity of MAC was greater in patients with moderate MR than in those with no or mild MR (P = .04). Three-dimensional analysis suggested an uneven distribution of annular calcium; the middle and lateral anterior segments were less often calcified than the anterior-medial or posterior segments. Calcification in any annular segment was highly associated with restricted motion of the attached leaflet segment. MAC is common and often extensive in hemodialysis patients. Calcium may be unevenly distributed among the annular segments. When present, annular calcification reduces the angle of leaflet opening and can cause valvular dysfunction. Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  13. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    PubMed

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  14. How Heart Valves Evolve to Adapt to an Extreme-Pressure System: Morphologic and Biomechanical Properties of Giraffe Heart Valves.

    PubMed

    Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik; Martin Bibby, Bo; Carl Andelius, Ted; Toft Brøndum, Emil; Wang, Tobias; Michael Hasenkam, J

    2017-01-01

    Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid in developing techniques to design improved pressure-resistant biological heart valves. Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations. The aortic valve was shown to be 70% (95% CI 42-103%) stronger in the giraffe than in its bovine counterpart (p <0.001). No significant difference was found between mitral or pulmonary valves. After normalization for collagen, no significant differences were found in strength between species. The giraffe aortic valve was found to be significantly stiffer than the bovine aortic valve (p <0.001), with no significant difference between mitral and pulmonary valves. On a dry weight basis, the aortic (10.9%), pulmonary (4.3%), and mitral valves (9.6%) of giraffes contained significantly more collagen than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength

  15. Loss of Axin2 results in impaired heart valve maturation and subsequent myxomatous valve disease.

    PubMed

    Hulin, Alexia; Moore, Vicky; James, Jeanne M; Yutzey, Katherine E

    2017-01-01

    Myxomatous valve disease (MVD) is the most common aetiology of primary mitral regurgitation. Recent studies suggest that defects in heart valve development can lead to heart valve disease in adults. Wnt/β-catenin signalling is active during heart valve development and has been reported in human MVD. The consequences of increased Wnt/β-catenin signalling due to Axin2 deficiency in postnatal valve remodelling and pathogenesis of MVD were determined. To investigate the role of Wnt/β-catenin signalling, we analysed heart valves from mice deficient in Axin2 (KO), a negative regulator of Wnt/β-catenin signalling. Axin2 KO mice display enlarged mitral and aortic valves (AoV) after birth with increased Wnt/β-catenin signalling and cell proliferation, whereas Sox9 expression and collagen deposition are decreased. At 2 months in Axin2 KO mice, the valve extracellular matrix (ECM) is stratified but distal AoV leaflets remain thickened and develop aortic insufficiency. Progressive myxomatous degeneration is apparent at 4 months with extensive ECM remodelling and focal aggrecan-rich areas, along with increased BMP signalling. Infiltration of inflammatory cells is also observed in Axin2 KO AoV prior to ECM remodelling. Overall, these features are consistent with the progression of human MVD. Finally, Axin2 expression is decreased and Wnt/β-catenin signalling is increased in myxomatous mitral valves in a murine model of Marfan syndrome, supporting the importance of Wnt/β-catenin signalling in the development of MVD. Altogether, these data indicate that Axin2 limits Wnt/β-catenin signalling after birth and allows proper heart valve maturation. Moreover, dysregulation of Wnt/β-catenin signalling resulting from loss of Axin2 leads to progressive MVD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For Permissions, please email: journals.permissions@oup.com.

  16. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.

    PubMed

    Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas

    2011-12-01

    As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Promotion of family planning services in practice leaflets.

    PubMed

    Marshall, M N; Gray, D J; Pearson, V; Phillips, D R; Owen, M

    1994-10-08

    Providing 75% of family planning services in the United Kingdom, general practitioners are required to produce leaflets which describe the contraceptive services they provide. The authors analyzed information about family planning provided to clients through practice leaflets. 88% of practice leaflets from the 198 practices in Devon were available from the Devon Family Health Services Authority for analysis. It was determined that the leaflets are not being best used to advertise the range and potential of family planning services. Although all practices in Devon offer contraceptive services, only 90% of leaflets mentioned that the services are available. Reference to postcoital contraception and information about services outside the practice for people who might not want to see their family doctor are also sorely lacking. A clear need exists to provide patients with more information. Finally, the authors found that group practices and those with female partners are most likely to give high priority to family planning issues in their leaflets.

  18. Pathology of myxomatous mitral valve disease in the dog.

    PubMed

    Fox, Philip R

    2012-03-01

    Mitral valve competence requires complex interplay between structures that comprise the mitral apparatus - the mitral annulus, mitral valve leaflets, chordae tendineae, papillary muscles, and left atrial and left ventricular myocardium. Myxomatous mitral valve degeneration is prevalent in the canine, and most adult dogs develop some degree of mitral valve disease as they age, highlighting the apparent vulnerability of canine heart valves to injury. Myxomatous valvular remodeling is associated with characteristic histopathologic features. Changes include expansion of extracellular matrix with glycosaminoglycans and proteoglycans; valvular interstitial cell alteration; and attenuation or loss of the collagen-laden fibrosa layer. These lead to malformation of the mitral apparatus, biomechanical dysfunction, and mitral incompetence. Mitral regurgitation is the most common manifestation of myxomatous valve disease and in advanced stages, associated volume overload promotes progressive valvular regurgitation, left atrial and left ventricular remodeling, atrial tears, chordal rupture, and congestive heart failure. Future studies are necessary to identify clinical-pathologic correlates that track disease severity and progression, detect valve dysfunction, and facilitate risk stratification. It remains unresolved whether, or to what extent, the pathobiology of myxomatous mitral valve degeneration is the same between breeds of dogs, between canines and humans, and how these features are related to aging and genetics. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Percutaneous Mitral Valve Dilatation: Single Balloon versus Double Balloon - A Finite Element Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schievano, Silvia; Kunzelman, Karyn; Nicosia, Mark

    2009-01-01

    Background: Percutaneous mitral valve (MV) dilatation is performed with either a single balloon (SB) or double balloon (DB) technique. The aim of this study was to compare the two balloon system results using the finite element (FE) method. Methods and Results: An established FE model of the MV was modified by fusing the MV leaflet edges at commissure level to simulate a stenotic valve (orifice area=180mm2). A FE model of a 30mm SB (low-pressure, elastomeric balloon) and an 18mm DB system (high-pressure, non-elastic balloon) was created. Both SB and DB simulations resulted in splitting of the commissures and subsequent stenosismore » dilatation (final MV area=610mm2 and 560mm2 respectively). Stresses induced by the two balloon systems varied across the valve. At the end of inflation, SB showed higher stresses in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. The higher stresses in the SB analysis were due to the mismatch of the round balloon shape with the oval mitral orifice. The commissural split was not easily accomplished with the SB due to its high compliance. The high pressure applied to the DB guaranteed the commissural split even when high forces were required to break the commissure welds. Conclusions: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in higher probability of splitting of the fused commissures and less damage caused to the MV leaflets by overstretching.« less

  20. Early Results of Rheumatic Mitral Valve Repair.

    PubMed

    Petrone, Giuseppe; Theodoropoulos, Panagiotis; Punjabi, Prakash P

    2016-11-01

    Mitral valve repair (MVr) in rheumatic heart disease (RHD) remains challenging. The present authors' surgical experience of MVr in 56 patients with RHD operated in between January 2011 and September 2014 is reported. Among the patients (mean age 32 ± 11 years), 11 were in NYHA functional class II, 32 in class III, and seven in class IV. An adequate or oversized autologous pericardial patch was sutured to extend the coaptating edge of both the anterior leaflet (in 18 patients) and the posterior leaflet (in 30 patients). Neochordae were implanted as needed (n = 43), and leaflet thinning (n = 13), commissurotomy (n = 15) and chordal splitting (n = 9) were also performed. A rigid annuloplasty ring was implanted in 32 patients, and in 24 patients a complete flexible annuloplasty ring made from pericardium, 4 mm Gore-Tex tube graft or a Dacron patch was constructed. Repair was not attempted in 16 patients, with replacement using a mechanical bileaflet prosthesis being considered the only option. Intraoperative post-repair transesophageal echocardiography demonstrated competency, with trivial mitral regurgitation (MR) up to grade I in all patients and a minimum coaptation depth ≥5 mm. There were no intraoperative or in-hospital deaths. Clinical and echocardiographic evaluations were performed up to six weeks after surgery, at which time 51 patients were in NYHA classes I-II and five were in class III. Residual mild MR up to grade I was identified in six patients. No recurrence of MR was observed in any of the patients, and no patients were reoperated on. The lack of adequate access to anticoagulation medication and monitoring, in addition to religious/cultural bias to the type of prosthetic valve used in low-income countries, necessitates an increase in the numbers of rheumatic MVr.

  1. Consent information leaflets – readable or unreadable?

    PubMed Central

    Graham, Caroline; Reynard, John M; Turney, Benjamin W

    2016-01-01

    Objective The objective of this article is to assess the readability of leaflets about urological procedures provided by the British Association of Urological Surgeons (BAUS) to evaluate their suitability for providing information. Methods Information leaflets were assessed using three measures of readability: Flesch Reading Ease, Flesch-Kincaid and Simple Measure of Gobbledygook (SMOG) grade formulae. The scores were compared with national literacy statistics. Results Relatively good readability was demonstrated using the Flesch Reading Ease (53.4–60.1) and Flesch-Kincaid Grade Level (6.5–7.6) methods. However, the average SMOG index (14.0–15.0) for each category suggests that the majority of the leaflets are written above the reading level of an 18-year-old. Using national literacy statistics, at least 43% of the population will have significant difficultly understanding the majority of these leaflets. Conclusions The results suggest that comprehension of the leaflets provided by the BAUS is likely to be poor. These leaflets may be used as an adjunct to discussion but it is essential to ensure that all the information necessary to make an informed decision has been conveyed in a way that can be understood by the patient. PMID:27867520

  2. Feasibility of pig and human-derived aortic valve interstitial cells seeding on fixative-free decellularized animal pericardium.

    PubMed

    Santoro, Rosaria; Consolo, Filippo; Spiccia, Marco; Piola, Marco; Kassem, Samer; Prandi, Francesca; Vinci, Maria Cristina; Forti, Elisa; Polvani, Gianluca; Fiore, Gianfranco Beniamino; Soncini, Monica; Pesce, Maurizio

    2016-02-01

    Glutaraldehyde-fixed pericardium of animal origin is the elective material for the fabrication of bio-prosthetic valves for surgical replacement of insufficient/stenotic cardiac valves. However, the pericardial tissue employed to this aim undergoes severe calcification due to chronic inflammation resulting from a non-complete immunological compatibility of the animal-derived pericardial tissue resulting from failure to remove animal-derived xeno-antigens. In the mid/long-term, this leads to structural deterioration, mechanical failure, and prosthesis leaflets rupture, with consequent need for re-intervention. In the search for novel procedures to maximize biological compatibility of the pericardial tissue into immunocompetent background, we have recently devised a procedure to decellularize the human pericardium as an alternative to fixation with aldehydes. In the present contribution, we used this procedure to derive sheets of decellularized pig pericardium. The decellularized tissue was first tested for the presence of 1,3 α-galactose (αGal), one of the main xenoantigens involved in prosthetic valve rejection, as well as for mechanical tensile behavior and distensibility, and finally seeded with pig- and human-derived aortic valve interstitial cells. We demonstrate that the decellularization procedure removed the αGAL antigen, maintained the mechanical characteristics of the native pig pericardium, and ensured an efficient surface colonization of the tissue by animal- and human-derived aortic valve interstitial cells. This establishes, for the first time, the feasibility of fixative-free pericardial tissue seeding with valve competent cells for derivation of tissue engineered heart valve leaflets. © 2015 Wiley Periodicals, Inc.

  3. [Functional tricuspid regurgitation and its relation to the morphology of the tricuspid valve and annulus: pulsed doppler echocardiography and two-dimensional echocardiography].

    PubMed

    Mikami, T; Kudo, T; Sakurai, N; Sakamoto, S; Tanabe, Y; Yasuda, H

    1983-06-01

    The mechanism for the development of functional tricuspid regurgitation (TR) was studied by an ultrasonic method. Thirty-five examinations were performed in 31 patients who were expected to have functional TR, and the severity was classified into 4 grades according to the extension of the regurgitant signals by pulsed Doppler echocardiography. The satisfactory horizontal section of the tricuspid valve was obtained by two-dimensional echocardiography (2DE) to measure the tricuspid annular diameter and to observe systolic configuration of the tricuspid valve in 22 examinations. The tricuspid annular diameter was well correlated with the severity of TR, and "lack of coaptation" of the valve was recognized on 2DE in some cases of severe TR with the markedly dilated annulus, indicating that this dilatation was an important trigger of functional TR. Additionally, in the majority of patients with severe TR, "anterior displacement" of the tips of tricuspid leaflet(s) (6 mm or more from the tricuspid annulus towards the right ventricle) was observed, which was thought to be due to the chordal traction secondary to the right ventricular dilatation, and contributed to the development of functional TR by disturbing sufficient coaptation. In one particular case, severe TR was associated with " malaligned coaptation" caused by the anterior displacement confined to the septal leaflet, indicating that asymmetrical dilatation of the right ventricle and/or disorientation of chordae-valve system may contribute to TR.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Nucleotide Catabolism on the Surface of Aortic Valve Xenografts; Effects of Different Decellularization Strategies.

    PubMed

    Kutryb-Zajac, Barbara; Yuen, Ada H Y; Khalpey, Zain; Zukowska, Paulina; Slominska, Ewa M; Taylor, Patricia M; Goldstein, Steven; Heacox, Albert E; Lavitrano, Marialuisa; Chester, Adrian H; Yacoub, Magdi H; Smolenski, Ryszard T

    2016-04-01

    Extracellular nucleotide metabolism controls thrombosis and inflammation and may affect degeneration and calcification of aortic valve prostheses. We evaluated the effect of different decellularization strategies on enzyme activities involved in extracellular nucleotide metabolism. Porcine valves were tested intact or decellularized either by detergent treatment or hypotonic lysis and nuclease digestion. The rates of ATP hydrolysis, AMP hydrolysis, and adenosine deamination were estimated by incubation of aorta or valve leaflet sections with substrates followed by HPLC analysis. We demonstrated relatively high activities of ecto-enzymes on porcine valve as compared to the aortic wall. Hypotonic lysis/nuclease digestion preserved >80 % of ATP and AMP hydrolytic activity but reduced adenosine deamination to <10 %. Detergent decellularization completely removed (<5 %) all these activities. These results demonstrate high intensity of extracellular nucleotide metabolism on valve surface and indicate that various valve decellularization techniques differently affect ecto-enzyme activities that could be important in the development of improved valve prostheses.

  5. Steady flow hemodynamic and energy loss measurements in normal and simulated calcified tricuspid and bicuspid aortic valves.

    PubMed

    Seaman, Clara; Akingba, A George; Sucosky, Philippe

    2014-04-01

    The bicuspid aortic valve (BAV), which forms with two leaflets instead of three as in the normal tricuspid aortic valve (TAV), is associated with a spectrum of secondary valvulopathies and aortopathies potentially triggered by hemodynamic abnormalities. While studies have demonstrated an intrinsic degree of stenosis and the existence of a skewed orifice jet in the BAV, the impact of those abnormalities on BAV hemodynamic performance and energy loss has not been examined. This steady-flow study presents the comparative in vitro assessment of the flow field and energy loss in a TAV and type-I BAV under normal and simulated calcified states. Particle-image velocimetry (PIV) measurements were performed to quantify velocity, vorticity, viscous, and Reynolds shear stress fields in normal and simulated calcified porcine TAV and BAV models at six flow rates spanning the systolic phase. The BAV model was created by suturing the two coronary leaflets of a porcine TAV. Calcification was simulated via deposition of glue beads in the base of the leaflets. Valvular performance was characterized in terms of geometric orifice area (GOA), pressure drop, effective orifice area (EOA), energy loss (EL), and energy loss index (ELI). The BAV generated an elliptical orifice and a jet skewed toward the noncoronary leaflet. In contrast, the TAV featured a circular orifice and a jet aligned along the valve long axis. While the BAV exhibited an intrinsic degree of stenosis (18% increase in maximum jet velocity and 7% decrease in EOA relative to the TAV at the maximum flow rate), it generated only a 3% increase in EL and its average ELI (2.10 cm2/m2) remained above the clinical threshold characterizing severe aortic stenosis. The presence of simulated calcific lesions normalized the alignment of the BAV jet and resulted in the loss of jet axisymmetry in the TAV. It also amplified the degree of stenosis in the TAV and BAV, as indicated by the 342% and 404% increase in EL, 70% and 51% reduction

  6. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.

    PubMed

    Dwyer, Harry A; Matthews, Peter B; Azadani, Ali; Jaussaud, Nicolas; Ge, Liang; Guy, T Sloane; Tseng, Elaine E

    2009-08-01

    Studied under clinical trials, transcatheter aortic valves (TAV) have demonstrated good short-term feasibility and results in high-risk surgical patients with severe aortic stenosis. However, their long-term safety and durability are unknown. The objective of this study is to evaluate hemodynamic changes within TAV created by bioprosthetic leaflet degeneration. Computational fluid dynamics (CFD) simulations were performed to evaluate the hemodynamics through TAV sclerosis (35% orifice reduction) and stenosis (78% orifice reduction). A three-dimensional surface mesh of the TAV within the aortic root was generated for each simulation. Leaflets were contained within an open, cylindrical body without attachment to the sinus commissures representing the stent. A continuous surface between the annulus and TAV excluded the geometry of the native calcified leaflets and prevented paravalvular leak. Unsteady control volume analysis throughout systole was used to calculate leaflet shear stress and total force on the TAV. Sclerosis increased total force on the TAV by 63% (0.602-0.98 N). Advancement of degeneration from sclerosis to stenosis was accompanied by an 86% increase in total force (1.82 N) but only a 32% increase in peak wall shear stress on the leaflets. Of the total force exerted on the TAV, 99% was in the direction of axial flow. Shear stresses on the TAV were greatest during peak systolic flow with stress concentrations on the tips of the leaflets. In the normal TAV, the aortic root geometry and physiologic flow dominate location and magnitude of shear stress. Following leaflet degeneration, the specific geometry of the stenosis dictates the profile of axial velocity leaving the TAV and shear stress on the leaflets. A dramatic increase in peak leaflet shear stress was observed (115 Pa stenosis vs. 87 Pa sclerosis and 29 Pa normal). CFD simulations in this study provide the first of its kind data quantifying hemodynamics within stenosed TAV. Stenosis leads to

  7. Hemodynamics of physiological blood flow in the aorta with nonlinear anisotropic heart valve

    NASA Astrophysics Data System (ADS)

    Sotiropoulos, Fotis; Gilmanov, Anvar; Stolarski, Henryk

    2016-11-01

    The hemodynamic blood flow in cardiovascular system is one of the most important factor, which causing several vascular diseases. We developed a new Curvilinear Immersed Boundary - Finite Element - Fluid Structure Interaction (CURVIB-FE-FSI) method to analyze hemodynamic of pulsatile blood flow in a real aorta with nonlinear anisotropic aortic valve at physiological conditions. Hyperelastic material model, which is more realistic for describing heart valve have been incorporated in the CURVIB-FE-FSI code to simulate interaction of aortic heart valve with pulsatile blood flow. Comparative studies of hemodynamics for linear and nonlinear models of heart valve show drastic differences in blood flow patterns and hence differences of stresses causing impact at leaflets and aortic wall. This work is supported by the Lillehei Heart Institute at the University of Minnesota.

  8. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves

    PubMed Central

    Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico

    2017-01-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078

  9. Medicine information leaflets for non-steroidal anti-inflammatory drugs in Thailand.

    PubMed

    Phueanpinit, Pacharaporn; Pongwecharak, Juraporn; Krska, Janet; Jarernsiripornkul, Narumol

    2016-02-01

    The importance of promoting the use of patient-oriented medicines leaflets is recognized in many countries. Leaflets should include basic information plus specific warnings, and be provided with all medicines, but there is little attempt at enforcement of these requirements in Thailand. To determine content and availability of Thai information leaflets for nonsteroidal anti-inflammatory drugs (NSAIDs). Leaflets for all NSAIDs available for purchase from 34 pharmacies in a large city were evaluated against a checklist and number of leaflets assessed against number of medicine packs available in each pharmacy. Of the 76 leaflets for ten different NSAIDs, 67 (88 %) were for locally manufactured products. Only 22 % of 76 leaflets were sufficient in number for distribution with medicines, while only 4 % had patient-oriented leaflets. No leaflet covered all topics in the checklist. Less than half included safety information, such as contraindications (46 %), precautions (47 %), and adverse drug reactions (34 %). Locally-produced leaflets provided less information than those for originator products and no leaflet included all the warnings required by Thai regulations. This study illustrates the variable availability and quality of NSAID information leaflets. The lack of accessible essential information about medicines in Thailand requires urgent attention to enable patients to minimise adverse reactions.

  10. Turbulence downstream of subcoronary stentless and stented aortic valves.

    PubMed

    Funder, Jonas Amstrup; Frost, Markus Winther; Wierup, Per; Klaaborg, Kaj-Erik; Hjortdal, Vibeke; Nygaard, Hans; Hasenkam, J Michael

    2011-08-11

    Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Pediatric Tubular Pulmonary Heart Valve from Decellularized Engineered Tissue Tubes

    PubMed Central

    Reimer, Jay M.; Syedain, Zeeshan H.; Haynie, Bee H.T.; Tranquillo, Robert T.

    2015-01-01

    Pediatric patients account for a small portion of the heart valve replacements performed, but a pediatric pulmonary valve replacement with growth potential remains an unmet clinical need. Herein we report the first tubular heart valve made from two decellularized, engineered tissue tubes attached with absorbable sutures, which can meet this need, in principle. Engineered tissue tubes were fabricated by allowing ovine dermal fibroblasts to replace a sacrificial fibrin gel with an aligned, cell-produced collagenous matrix, which was subsequently decellularized. Previously, these engineered tubes became extensively recellularized following implantation into the sheep femoral artery. Thus, a tubular valve made from these tubes may be amenable to recellularization and, ideally, somatic growth. The suture line pattern generated three equi-spaced “leaflets” in the inner tube, which collapsed inward when exposed to back pressure, per tubular valve design. Valve testing was performed in a pulse duplicator system equipped with a secondary flow loop to allow for root distention. All tissue-engineered valves exhibited full leaflet opening and closing, minimal regurgitation (< 5%), and low systolic pressure gradients (< 2.5 mmHg) under pulmonary conditions. Valve performance was maintained under various trans-root pressure gradients and no tissue damage was evident after 2 million cycles of fatigue testing. PMID:26036175

  12. Development and evaluation of a pliable biological valved conduit. Part II: Functional and hemodynamic evaluation.

    PubMed

    Sung, H W; Witzel, T H; Hata, C; Tu, R; Shen, S H; Lin, D; Noishiki, Y; Tomizawa, Y; Quijano, R C

    1993-04-01

    Many congenital cardiac malformations may require a valved conduit for the reconstruction of the right ventricular outflow tract. In spite of many endeavors made in the last 25 years, the clinical results of right ventricular outflow tract reconstruction with currently available valved conduits are still not satisfactory. Specific problems encountered clinically include suboptimal hemodynamic performance, conduit kinking or compression, and fibrous peeling from the luminal surface. To address these deficiencies, we undertook the development of a biological valved conduit: a bovine external jugular vein graft with a retained native valve cross-linked with a diglycidyl ether (DE). This study, using a canine model, was to evaluate the functional and hemodynamic performance of this newly developed valved conduit. Three 14 mm conduits, implanted as bypass grafts, right ventricle to pulmonary artery, were evaluated. The evaluation was conducted with a noninvasive color Doppler flow mapping system at pre-implantation, immediately post implantation, one- and three-months post implantation, and prior to retrieval (five-months post implantation). The two-dimensional tomographic inspection of the leaflet motion at various periods post implantation showed that the valvular leaflets in the DE treated conduit was quite pliable. No cardiac failure or valvular dysfunction was observed in any of the studied cases. The color Doppler flow mapping study demonstrated that the valve in the DE treated conduit was competent, with no conduit kinking or compression observed in any of the three cases. The spectral Doppler velocity study evidenced that the transvalvular pressure gradients of the DE treated conduit were minimal as compared to those of the currently available conduits. In conclusion, from the functional and hemodynamic performance points of view, this newly developed valved conduit is superior to those currently available.

  13. A rare native mitral valve endocarditis successfully treated after surgical correction

    PubMed Central

    Garcia, Daniel C; Nascimento, Rhanderson; Soto, Victor; Mendoza, Cesar E

    2014-01-01

    Mycobacterium abscessus and Kocuria species are rare causes of infections in humans. Endocarditis by these agents has been reported in only 11 cases. M. abscessus is a particularly resistant organism and treatment requires the association of antibiotics for a prolonged period of time. We report a case of native mitral valve bacterial endocarditis due to M. abscessus and Kocuria species in a 48-year-old man with a history of intravenous drug use. The case was complicated by a perforation of the posterior mitral valve leaflet, leading to surgical mitral valve replacement. Cultures from the blood and mitral valve disclosed M. abscessus and Kocuria species. The patient was treated for 6 months with clarithromycin, imipenem and amikacin, with resolution of symptoms. Repeated blood cultures were negative. Acid-fast staining should be done in subacute endocarditis in order to identify rapidly growing mycobacteria. PMID:25270154

  14. Isolated Effect of Geometry on Mitral Valve Function for In-Silico Model Development

    PubMed Central

    Siefert, Andrew William; Rabbah, Jean-Pierre Michel; Saikrishnan, Neelakantan; Kunzelman, Karyn Susanne; Yoganathan, Ajit Prithivaraj

    2013-01-01

    Computational models for the heart’s mitral valve (MV) exhibit several uncertainties which may be reduced by further developing these models using ground-truth data sets. The present study generated a ground-truth data set by quantifying the effects of isolated mitral annular flattening, symmetric annular dilatation, symmetric papillary muscle displacement, and asymmetric papillary muscle displacement on leaflet coaptation, mitral regurgitation (MR), and anterior leaflet strain. MVs were mounted in an in vitro left heart simulator and tested under pulsatile hemodynamics. Mitral leaflet coaptation length, coaptation depth, tenting area, MR volume, MR jet direction, and anterior leaflet strain in the radial and circumferential directions were successfully quantified for increasing levels of geometric distortion. From these data, increasing levels of isolated papillary muscle displacement resulted in the greatest mean change in coaptation depth (70% increase), tenting area (150% increase), and radial leaflet strain (37% increase) while annular dilatation resulted in the largest mean change in coaptation length (50% decrease) and regurgitation volume (134% increase). Regurgitant jets were centrally located for symmetric annular dilatation and symmetric papillary muscle displacement. Asymmetric papillary muscle displacement resulted in asymmetrically directed jets. Peak changes in anterior leaflet strain in the circumferential direction were smaller and exhibited non-significant differences across the tested conditions. When used together, this ground-truth data may be used to parametrically evaluate and develop modeling assumptions for both the MV leaflets and subvalvular apparatus. This novel data may improve MV computational models and provide a platform for the development of future surgical planning tools. PMID:24059354

  15. Isolated effect of geometry on mitral valve function for in silico model development.

    PubMed

    Siefert, Andrew William; Rabbah, Jean-Pierre Michel; Saikrishnan, Neelakantan; Kunzelman, Karyn Susanne; Yoganathan, Ajit Prithivaraj

    2015-01-01

    Computational models for the heart's mitral valve (MV) exhibit several uncertainties that may be reduced by further developing these models using ground-truth data-sets. This study generated a ground-truth data-set by quantifying the effects of isolated mitral annular flattening, symmetric annular dilatation, symmetric papillary muscle (PM) displacement and asymmetric PM displacement on leaflet coaptation, mitral regurgitation (MR) and anterior leaflet strain. MVs were mounted in an in vitro left heart simulator and tested under pulsatile haemodynamics. Mitral leaflet coaptation length, coaptation depth, tenting area, MR volume, MR jet direction and anterior leaflet strain in the radial and circumferential directions were successfully quantified at increasing levels of geometric distortion. From these data, increase in the levels of isolated PM displacement resulted in the greatest mean change in coaptation depth (70% increase), tenting area (150% increase) and radial leaflet strain (37% increase) while annular dilatation resulted in the largest mean change in coaptation length (50% decrease) and regurgitation volume (134% increase). Regurgitant jets were centrally located for symmetric annular dilatation and symmetric PM displacement. Asymmetric PM displacement resulted in asymmetrically directed jets. Peak changes in anterior leaflet strain in the circumferential direction were smaller and exhibited non-significant differences across the tested conditions. When used together, this ground-truth data-set may be used to parametrically evaluate and develop modelling assumptions for both the MV leaflets and subvalvular apparatus. This novel data may improve MV computational models and provide a platform for the development of future surgical planning tools.

  16. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    PubMed Central

    Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen

  17. First uses of HAART 300 rings for aortic valve repair in Poland - 4 case studies.

    PubMed

    Juściński, Jacek H; Koprowski, Andrzej; Kołaczkowska, Magdalena; Kowalik, Maciej M; Rogowski, Jan A; Rankin, James S

    2018-03-01

    Aortic valve reconstructions using geometric annuloplasty rings HAART 300/200 open new era in aortic valve surgery. The HAART technology resizes, reshapes, stabilizes and simplifies aortic valve repair. The HAART aortic repair rings are designed to be implanted directly into aortic annulus (under aortic valve leaflets). We present first in Poland 4 cases of aortic valve reconstructions using geometric annuloplasty rings HAART 300. Two patients had type IA aortic insufficiency (due to El-Khoury classification) - they were treated by HAART 300 ring insertion and ascending aorta prosthesis implantation. Third patient, Marfan with type IB aortic insufficiency was repaired by HAART 300 ring implantation followed by remodeling (Yacoub) procedure. Fourth patient with type II aortic insufficiency (due to RCC prolapse) was repaired by HAART 300 implantation and cusp plication. All patients shows good results on 6 months postoperative 3D TTE examinations. Presented technique is reproducible and simplify aortic valve reconstructions.

  18. Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.

    PubMed

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki

    2016-08-01

    The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.

  19. Infective endocarditis of native valve after anterior nasal packing.

    PubMed

    Jayawardena, Suriya; Eisdorfer, Jacob; Indulkar, Shalaka; Zarkaria, Muhammad

    2006-01-01

    We present a case report of a patient who was previously treated for spontaneous epistaxis with a petroleum jelly gauze (0.5 in x 72 in) anterior nasal packing filled with an antibiotic ointment, along with prophylactic oral clindamycin. The patient presented with fever and hypotension 3 days after the nasal packing. Her blood cultures grew methicillin-resistant Staphylococcus aureus and the transesophageal echocardiography showed vegetation on the atrial surface of the posterior mitral valve leaflet, confirming the diagnosis of bacterial endocarditis attributable to nasal packing. Several case reports discuss toxic shock syndrome after nasal packing, but none describe endocarditis of the native heart valves subsequent to anterior nasal packing. Current guidelines on endocarditis prophylaxis produced by the American Heart Association, European Cardiac Society, and British Cardiac Society together with published evidence do not recommend endocarditis prophylaxis for patients with native heart valves undergoing anterior nasal packing.

  20. Knitting for heart valve tissue engineering

    PubMed Central

    Ayad, Nadia; Wojciechowska, Dorota; Zielińska, Dorota; Struszczyk, Marcin H.; Latif, Najma; Yacoub, Magdi

    Knitting is a versatile technology which offers a large portfolio of products and solutions of interest in heart valve (HV) tissue engineering (TE). One of the main advantages of knitting is its ability to construct complex shapes and structures by precisely assembling the yarns in the desired position. With this in mind, knitting could be employed to construct a HV scaffold that closely resembles the authentic valve. This has the potential to reproduce the anisotropic structure that is characteristic of the heart valve with the yarns, in particular the 3-layered architecture of the leaflets. These yarns can provide oriented growth of cells lengthwise and consequently enable the deposition of extracellular matrix (ECM) proteins in an oriented manner. This technique, therefore, has a potential to provide a functional knitted scaffold, but to achieve that textile engineers need to gain a basic understanding of structural and mechanical aspects of the heart valve and in addition, tissue engineers must acquire the knowledge of tools and capacities that are essential in knitting technology. The aim of this review is to provide a platform to consolidate these two fields as well as to enable an efficient communication and cooperation among these two research areas. PMID:29043276

  1. Valve repair for traumatic tricuspid regurgitation.

    PubMed

    Maisano, F; Lorusso, R; Sandrelli, L; Torracca, L; Coletti, G; La Canna, G; Alfieri, O

    1996-01-01

    The review of six cases of valve repair for traumatic tricuspid regurgitation in our institution and 74 in the literature in order to assess effective methods of treating this lesion. Tricuspid valve regurgitation is a rare complication of blunt chest trauma. Optimal treatment for this condition is still controversial ranging from long-term medical therapy to early surgical correction. We followed the cases of six consecutive patients with post-traumatic tricuspid incompetence who were successfully treated with reparative techniques. All patients were male and their ages ranged from 18 years to 42 years. Valve regurgitation was always secondary to blunt chest trauma due to motor vehicle accident. The mechanism of valve insufficiency was invariably anterior leaflet prolapse due to chordal or papillary muscle rupture associated with annular dilatation. Surgical procedures included Carpentier ring implant (5 patients), Bex posterior annuloplasty (1 patient), implant of artificial chordae (4 patients), papillary muscle reinsertion (2 patients), commissuroplasty (1 patient) and "artificial double orifice" technique (1 patient). Tricuspid insufficiency improved in all patients after the correction. No complications were recorded and all patients were asymptomatic at the follow-up. Since post-traumatic tricuspid regurgitation is effectively correctable with reparative techniques, early operation is recommended to relieve symptoms and to prevent right ventricular dysfunction.

  2. Simple versus complex degenerative mitral valve disease.

    PubMed

    Javadikasgari, Hoda; Mihaljevic, Tomislav; Suri, Rakesh M; Svensson, Lars G; Navia, Jose L; Wang, Robert Z; Tappuni, Bassman; Lowry, Ashley M; McCurry, Kenneth R; Blackstone, Eugene H; Desai, Milind Y; Mick, Stephanie L; Gillinov, A Marc

    2018-07-01

    At a center where surgeons favor mitral valve (MV) repair for all subsets of leaflet prolapse, we compared results of patients undergoing repair for simple versus complex degenerative MV disease. From January 1985 to January 2016, 6153 patients underwent primary isolated MV repair for degenerative disease, 3101 patients underwent primary isolated MV repair for simple disease (posterior prolapse), and 3052 patients underwent primary isolated MV repair for complex disease (anterior or bileaflet prolapse), based on preoperative echocardiographic images. Logistic regression analysis was used to generate propensity scores for risk-adjusted comparisons (n = 2065 matched pairs). Durability was assessed by longitudinal recurrence of mitral regurgitation and reoperation. Compared with patients with simple disease, those undergoing repair of complex pathology were more likely to be younger and female (both P values < .0001) but with similar symptoms (P = .3). The most common repair technique was ring/band annuloplasty (3055/99% simple vs 3000/98% complex; P = .5), followed by leaflet resection (2802/90% simple vs 2249/74% complex; P < .0001). Among propensity-matched patients, recurrence of severe mitral regurgitation 10 years after repair was 6.2% for simple pathology versus 11% for complex pathology (P = .007), reoperation at 18 years was 6.3% for simple pathology versus 11% for complex pathology, and 20-year survival was 62% for simple pathology versus 61% for complex pathology (P = .6). Early surgical intervention has become more common in patients with degenerative MV disease, regardless of valve prolapse complexity or symptom status. Valve repair was associated with similarly low operative risk and time-related survival but less durability in complex disease. Lifelong annual echocardiographic surveillance after MV repair is recommended, particularly in patients with complex disease. Copyright © 2018 The American Association for Thoracic Surgery

  3. Transcatheter treatment of tricuspid regurgitation by caval valve implantation--experimental evaluation of decellularized tissue valves in central venous position.

    PubMed

    Lauten, Alexander; Laube, Adrian; Schubert, Harald; Bischoff, Sabine; Nietzsche, Sandor; Horstkötter, Kim; Poudel-Bochmann, Bhawana; Franz, Marcus; Lichtenberg, Artur; Figulla, Hans R; Akhyari, Payam

    2015-01-01

    Caval valve implantation has been suggested for transcatheter treatment of severe tricuspid regurgitation (TR). Combining the interventional technique with the promising surgical experience with decellularized valves, we sought to evaluate the functional and structural outcome of decellularized pericardial tissue valves (dTVs) in the low-pressure venous circulation in a chronic model of TR. Sixteen pericardial tissue valves were heterotopically implanted in the inferior and superior vena cava in a sheep model (54-98 kg; median 74.5 kg, n = 8) of severe TR. The devices were assembled using self-expanding nitinol stents and bovine pericardia decellularized by a detergent-based protocol (group dTV; n = 8). Glutaraldehyde-fixed pericardial tissue valves served as control (GaTV, n = 8). After 6 months, device function and structural maturation were analyzed using echocardiographic, histologic, immunohistologic, and electron microscopic approaches. After implantation, cardiac output increased significantly from 3.7 ± 1.1 l/min to 4.8 ± 1.1 l/min (P < 0.05) and competent valve function was verified by angiography. At 6 months, angiographic and echocardiographic evaluation revealed moderate to severe regurgitation in all GaTV. In contrast, five of the eight dTVs functioned well with only minor regurgitation. In these animals, autopsy revealed preserved valve structure with tender leaflets without signs of thrombosis or calcification. Conversely, GaTV showed severe degeneration with large calcification areas. Microscopic and histologic analysis confirmed endothelial repopulation in both valve types. However, additional interstitial reseeding was observed in decellularized valves. In the venous circulation in severe TR, decellularized valves show superior functional performance compared to Ga-fixed tissue valves. Macroscopic and microscopic analyses suggest preserved structural integrity and advanced endothelial and interstitial repopulation with

  4. Maximal Aortic Valve Cusp Separation and Severity of Aortic Stenosis

    PubMed Central

    Dilu, VP; George, Raju

    2017-01-01

    Introduction An integrated approach that incorporates two dimensional, M mode and Doppler echocardiographic evaluation has become the standard means for accurate quantification of severity of valvular aortic stenosis. Maximal separation of the aortic valve cusps during systole has been shown to correlate well with the severity of aortic stenosis measured by other echocardiographic parameters. Aim To study the correlation between Maximal Aortic valve Cusp Separation (MACS) and severity of aortic valve stenosis and to find cut-off values of MACS for detecting severe and mild aortic stenosis. Materials and Methods In the present prospective observational study, we have compared the accuracy of MACS distance and the aortic valve area calculated by continuity equation in 59 patients with varying degrees of aortic valve stenosis. Aortic leaflet separation in M mode was identified as the distance between the inner edges of the tips of these structures at mid systole in the parasternal long axis view. Cuspal separation was also measured in 2D echocardiography from the parasternal long axis view and the average of the two values was taken as the MACS. Patients were grouped into mild, moderate and severe aortic stenosis based on the aortic valve area calculated by continuity equation. The resultant data regarding maximal leaflet separation on cross-sectional echocardiogram was then subjected to linear regression analysis in regard to correlation with the peak transvalvular aortic gradient as well as the calculated aortic valve area. A cut-off value for each group was derived using ROC curve. Results There was a strong correlation between MACS and aortic valve area measured by continuity equation and the peak and mean transvalvular aortic gradients. Mean MACS was 6.89 mm in severe aortic stenosis, 9.97 mm in moderate aortic stenosis and 12.36 mm in mild aortic stenosis. MACS below 8.25 mm reliably predicted severe aortic stenosis, with high sensitivity, specificity and

  5. Morphometric analysis of tricuspid valve: An Indian perspective

    PubMed Central

    Kalyani, R.; Thej, M. J.; Prabhakar, K.; Venkatesh, T. K.; Thomas, A. K.; Kiran, J.

    2012-01-01

    Background: The morphometry of tricuspid valve complex is of clinical importance for cardiovascular surgeons and there is scarcity of such data in Indian literature. The study was conducted to record normal tricuspid valve measurements which would serve as baseline data for the Indian population. Material and Methods: The study was carried out on 100 formalin fixed hearts without any pathology from patients who had died of non-vascular causes and whose age ranged from 8 to 85 yrs. The hearts were grouped into three cohorts corresponding to age, 54 hearts aged between 8 to 40 yrs, 42 hearts aged between 41 to 64 yrs and 4 hearts aged 65 yrs and above. Dissection was performed according to standard autopsy techniques. The measurements were recorded using a flexible millimeter ruler and surgical suture material. The dimensions measured were the attachment lengths of anterior, posterior and septal leaflets. The circumference of the valve along with the frontal and sagittal dimensions was measured. Area of the valve expressed as a triangle and as an ellipse was calculated. Results: The measurements obtained were assessed using SPSS software. Statistically significant increase in tricuspid valve measurements were observed with advancing age both in men and women. In younger hearts the tricuspid valve resembled a triangle and with advancing age the tricuspid valve became more elliptical in shape. Conclusion: We hope this study will serve as baseline data for the tricuspid valve measurements in the Indian population and it will be of clinical use for patients with various tricuspid valve abnormalities. PMID:23225976

  6. Interleukin-37 suppresses the osteogenic responses of human aortic valve interstitial cells in vitro and alleviates valve lesions in mice.

    PubMed

    Zeng, Qingchun; Song, Rui; Fullerton, David A; Ao, Lihua; Zhai, Yufeng; Li, Suzhao; Ballak, Dov B; Cleveland, Joseph C; Reece, T Brett; McKinsey, Timothy A; Xu, Dingli; Dinarello, Charles A; Meng, Xianzhong

    2017-02-14

    Calcific aortic valve disease is a chronic inflammatory process, and aortic valve interstitial cells (AVICs) from diseased aortic valves express greater levels of osteogenic factors in response to proinflammatory stimulation. Here, we report that lower cellular levels of IL-37 in AVICs of diseased human aortic valves likely account for augmented expression of bone morphogenetic protein-2 (BMP-2) and alkaline phosphatase (ALP) following stimulation of Toll-like receptor (TLR) 2 or 4. Treatment of diseased AVICs with recombinant human IL-37 suppresses the levels of BMP-2 and ALP as well as calcium deposit formation. In mice, aortic valve thickening is observed when exposed to a TLR4 agonist or a high fat diet for a prolonged period; however, mice expressing human IL-37 exhibit significantly lower BMP-2 levels and less aortic valve thickening when subjected to the same regimens. A high fat diet in mice results in oxidized low-density lipoprotein (oxLDL) deposition in aortic valve leaflets. Moreover, the osteogenic responses in human AVICs induced by oxLDL are suppressed by recombinant IL-37. Mechanistically, reduced osteogenic responses to oxLDL in human AVICs are associated with the ability of IL-37 to inhibit NF-κB and ERK1/2. These findings suggest that augmented expression of osteogenic factors in AVICs of diseased aortic valves from humans is at least partly due to a relative IL-37 deficiency. Because recombinant IL-37 suppresses the osteogenic responses in human AVICs and alleviates aortic valve lesions in mice exposed to high fat diet or a proinflammatory stimulus, IL-37 has therapeutic potential for progressive calcific aortic valve disease.

  7. Interleukin-37 suppresses the osteogenic responses of human aortic valve interstitial cells in vitro and alleviates valve lesions in mice

    PubMed Central

    Zeng, Qingchun; Song, Rui; Fullerton, David A.; Ao, Lihua; Zhai, Yufeng; Li, Suzhao; Ballak, Dov B.; Cleveland, Joseph C.; Reece, T. Brett; McKinsey, Timothy A.; Xu, Dingli; Dinarello, Charles A.; Meng, Xianzhong

    2017-01-01

    Calcific aortic valve disease is a chronic inflammatory process, and aortic valve interstitial cells (AVICs) from diseased aortic valves express greater levels of osteogenic factors in response to proinflammatory stimulation. Here, we report that lower cellular levels of IL-37 in AVICs of diseased human aortic valves likely account for augmented expression of bone morphogenetic protein-2 (BMP-2) and alkaline phosphatase (ALP) following stimulation of Toll-like receptor (TLR) 2 or 4. Treatment of diseased AVICs with recombinant human IL-37 suppresses the levels of BMP-2 and ALP as well as calcium deposit formation. In mice, aortic valve thickening is observed when exposed to a TLR4 agonist or a high fat diet for a prolonged period; however, mice expressing human IL-37 exhibit significantly lower BMP-2 levels and less aortic valve thickening when subjected to the same regimens. A high fat diet in mice results in oxidized low-density lipoprotein (oxLDL) deposition in aortic valve leaflets. Moreover, the osteogenic responses in human AVICs induced by oxLDL are suppressed by recombinant IL-37. Mechanistically, reduced osteogenic responses to oxLDL in human AVICs are associated with the ability of IL-37 to inhibit NF-κB and ERK1/2. These findings suggest that augmented expression of osteogenic factors in AVICs of diseased aortic valves from humans is at least partly due to a relative IL-37 deficiency. Because recombinant IL-37 suppresses the osteogenic responses in human AVICs and alleviates aortic valve lesions in mice exposed to high fat diet or a proinflammatory stimulus, IL-37 has therapeutic potential for progressive calcific aortic valve disease. PMID:28137840

  8. Content analysis of nutritional information in paediatric oral health education leaflets.

    PubMed

    Arora, Amit; Doan, Jenny; Martinez, Jessamine; Phan, Colin; Kolt, Gregory S; Bhole, Sameer; Harris, Mark Fort; Scott, Jane Anne; Hector, Debra

    2017-02-20

    The aim of this study was to determine if paediatric oral health education leaflets with a food and nutritional focus provide messages that are clear and consistent with the current Australian Dietary Guidelines and the Infant Feeding Guidelines. Forty-three leaflets aimed at parents were sourced from Australian state and territory Health Departments, oral health industry partners and commercial organisations, and a content analysis was performed. Recommendations on food and drink type, consumption frequency and general diet and nutrition advice were considered and cross-referenced with the Australian Dietary Guidelines and the Infant Feeding Guidelines to identify areas of consistency and discrepancy. Twenty leaflets recommended reducing the consumption of sugary and/or acidic food, while 23 leaflets recommended reducing the consumption of sugary and/or acidic drinks. The majority of the leaflets advised water (n = 35) and milk (n = 23) to drink. Although 33 leaflets encouraged a healthy diet, seven of these did not specify what a healthy diet was. Twenty-eight leaflets provided early childhood-related (0-2 years) feeding advice. Confusing messages were found in nine leaflets, with ambiguous recommendations that were open to individual interpretation. There were some inconsistencies between the leaflets and the dietary and infant feeding guidelines in Australia; and across the leaflets, as not all important messages were included in any one leaflet. Government Health Departments and other relevant agencies should ensure that advisory messages regarding diet, particularly those with dental implications, are clear, complete and consistent across all dental educational leaflets.

  9. A novel left heart simulator for the multi-modality characterization of native mitral valve geometry and fluid mechanics.

    PubMed

    Rabbah, Jean-Pierre; Saikrishnan, Neelakantan; Yoganathan, Ajit P

    2013-02-01

    Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental validation. As computational solvers vary considerably, experimental benchmark data are critically important to ensure model accuracy. In this study, a novel left heart simulator was designed specifically for the validation of numerical mitral valve models. Several distinct experimental techniques were collectively performed to resolve mitral valve geometry and hemodynamics. In particular, micro-computed tomography was used to obtain accurate and high-resolution (39 μm voxel) native valvular anatomy, which included the mitral leaflets, chordae tendinae, and papillary muscles. Three-dimensional echocardiography was used to obtain systolic leaflet geometry. Stereoscopic digital particle image velocimetry provided all three components of fluid velocity through the mitral valve, resolved every 25 ms in the cardiac cycle. A strong central filling jet (V ~ 0.6 m/s) was observed during peak systole with minimal out-of-plane velocities. In addition, physiologic hemodynamic boundary conditions were defined and all data were synchronously acquired through a central trigger. Finally, the simulator is a precisely controlled environment, in which flow conditions and geometry can be systematically prescribed and resultant valvular function and hemodynamics assessed. Thus, this work represents the first comprehensive database of high fidelity experimental data, critical for extensive validation of mitral valve fluid structure interaction simulations.

  10. Non-Dimensional Formulation of Ventricular Work-Load Severity Under Concomitant Heart Valve Disease

    NASA Astrophysics Data System (ADS)

    Dong, Melody; Simon-Walker, Rachael; Dasi, Lakshmi

    2012-11-01

    Current guidelines on assessing the severity of heart valve disease rely on dimensional disease specific measures and are thus unable to capture severity under a concomitant heart valve disease scenario. Experiments were conducted to measure ventricular work-load in an in-house in-vitro left heart simulator. In-house tri-leaflet heart valves were built and parameterized to model concomitant heart valve disease. Measured ventricular power varied non-linearly with cardiac output and mean aortic pressure. Significant data collapse could be achieved by the non-dimensionalization of ventricular power with cardiac output, fluid density, and a length scale. The dimensionless power, Circulation Energy Dissipation Index (CEDI), indicates that concomitant conditions require a significant increase in the amount of work needed to sustain cardiac function. It predicts severity without the need to quantify individual disease severities. This indicates the need for new fluid-dynamics similitude based clinical guidelines to assist patients with multiple heart valve diseases. Funded by the American Heart Association.

  11. Clinical Significance of Markers of Collagen Metabolism in Rheumatic Mitral Valve Disease

    PubMed Central

    Banerjee, Tanima; Mukherjee, Somaditya; Ghosh, Sudip; Biswas, Monodeep; Dutta, Santanu; Pattari, Sanjib; Chatterjee, Shelly; Bandyopadhyay, Arun

    2014-01-01

    Background Rheumatic Heart Disease (RHD), a chronic acquired heart disorder results from Acute Rheumatic Fever. It is a major public health concern in developing countries. In RHD, mostly the valves get affected. The present study investigated whether extracellular matrix remodelling in rheumatic valve leads to altered levels of collagen metabolism markers and if such markers can be clinically used to diagnose or monitor disease progression. Methodology This is a case control study comprising 118 subjects. It included 77 cases and 41 healthy controls. Cases were classified into two groups- Mitral Stenosis (MS) and Mitral Regurgitation (MR). Carboxy-terminal propeptide of type I procollagen (PICP), amino-terminal propeptide of type III procollagen (PIIINP), total Matrix Metalloproteinase-1(MMP-1) and Tissue Inhibitor of Metalloproteinase-1 (TIMP-1) were assessed. Histopathology studies were performed on excised mitral valve leaflets. A p value <0.05 was considered statistically significant. Results Plasma PICP and PIIINP concentrations increased significantly (p<0.01) in MS and MR subjects compared to controls but decreased gradually over a one year period post mitral valve replacement (p<0.05). In MS, PICP level and MMP-1/TIMP-1 ratio strongly correlated with mitral valve area (r = −0.40; r = 0.49 respectively) and pulmonary artery systolic pressure (r = 0.49; r = −0.49 respectively); while in MR they correlated with left ventricular internal diastolic (r = 0.68; r = −0.48 respectively) and systolic diameters (r = 0.65; r = −0.55 respectively). Receiver operating characteristic curve analysis established PICP as a better marker (AUC = 0.95; 95% CI = 0.91−0.99; p<0.0001). A cut-off >459 ng/mL for PICP provided 91% sensitivity, 90% specificity and a likelihood ratio of 9 in diagnosing RHD. Histopathology analysis revealed inflammation, scarring, neovascularisation and extensive leaflet fibrosis in diseased mitral

  12. Vector flow mapping in obstructive hypertrophic cardiomyopathy to assess the relationship of early systolic left ventricular flow and the mitral valve.

    PubMed

    Ro, Richard; Halpern, Dan; Sahn, David J; Homel, Peter; Arabadjian, Milla; Lopresto, Charles; Sherrid, Mark V

    2014-11-11

    The hydrodynamic cause of systolic anterior motion of the mitral valve (SAM) is unresolved. This study hypothesized that echocardiographic vector flow mapping, a new echocardiographic technique, would provide insights into the cause of early SAM in obstructive hypertrophic cardiomyopathy (HCM). We analyzed the spatial relationship of left ventricular (LV) flow and the mitral valve leaflets (MVL) on 3-chamber vector flow mapping frames, and performed mitral valve measurements on 2-dimensional frames in patients with obstructive and nonobstructive HCM and in normal patients. We compared 82 patients (22 obstructive HCM, 23 nonobstructive HCM, and 37 normal) by measuring 164 LV pre- and post-SAM velocity vector flow maps, 82 maximum isovolumic vortices, and 328 2-dimensional frames. We observed color flow and velocity vector flow posterior to the MVL impacting them in the early systolic frames of 95% of obstructive HCM, 22% of nonobstructive HCM, and 11% of normal patients (p < 0.001). In both pre- and post-SAM frames, we measured a high angle of attack >60° of local vector flow onto the posterior surface of the leaflets whether the flow was ejection (59%) or the early systolic isovolumic vortex (41%). Ricochet of vector flow, rebounding off the leaflet into the cul-de-sac, was noted in 82% of the obstructed HCM, 9% of nonobstructive HCM, and none (0%) of the control patients (p < 0.001). Flow velocities in the LV outflow tract on the pre-SAM frame 1 and 2 mm from the tip of the anterior leaflet were low: 39 and 43 cm/s, respectively. Early systolic flow impacts the posterior surfaces of protruding MVL initiating SAM in obstructive HCM. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Ultrasound based mitral valve annulus tracking for off-pump beating heart mitral valve repair

    NASA Astrophysics Data System (ADS)

    Li, Feng P.; Rajchl, Martin; Moore, John; Peters, Terry M.

    2014-03-01

    Mitral regurgitation (MR) occurs when the mitral valve cannot close properly during systole. The NeoChordtool aims to repair MR by implanting artificial chordae tendineae on flail leaflets inside the beating heart, without a cardiopulmonary bypass. Image guidance is crucial for such a procedure due to the lack of direct vision of the targets or instruments. While this procedure is currently guided solely by transesophageal echocardiography (TEE), our previous work has demonstrated that guidance safety and efficiency can be significantly improved by employing augmented virtuality to provide virtual presentation of mitral valve annulus (MVA) and tools integrated with real time ultrasound image data. However, real-time mitral annulus tracking remains a challenge. In this paper, we describe an image-based approach to rapidly track MVA points on 2D/biplane TEE images. This approach is composed of two components: an image-based phasing component identifying images at optimal cardiac phases for tracking, and a registration component updating the coordinates of MVA points. Preliminary validation has been performed on porcine data with an average difference between manually and automatically identified MVA points of 2.5mm. Using a parallelized implementation, this approach is able to track the mitral valve at up to 10 images per second.

  14. Transapical endovascular implantation of neochordae using a suction and suture device.

    PubMed

    Maisano, Francesco; Michev, Iassen; Rowe, Stanton; Addis, Alessandro; Campagnol, Marino; Guidotti, Andrea; Colombo, Antonio; Alfieri, Ottavio

    2009-07-01

    Neochordae implantation is a standard method for treatment of mitral valve prolapse. We describe a transcatheter technology enabling transapical endovascular chordal implantation. Six adult pigs were anesthetized. Two 10F sheaths were introduced in the femoral vessels for monitoring and intracardiac echo. After midline sternotomy, the pericardium was opened, the apex was punctured inside two 2-0 polypropylene purse strings. A 0.035 in J tipped guidewire was introduced in the left ventricle and an ultra stiff 14F sheath (guide catheter) inserted through the apex. A suction-and-suture device was introduced in the left ventricle. The mitral valve was crossed under echo guidance. Using suction, either the anterior (two cases) or posterior (four cases) leaflet was captured and a loop of 4-0 polypropylene was thrown at the edge of the leaflet. The loop, with a pledget, was exteriorized through the introducer. The introducer was removed and the purse-string tied. Under echo guidance, the neochordae suture was pulled and tied over a pledget to evoke leaflet tethering. The animals were sacrificed and gross anatomy reviewed. Leaflet capture was feasible in the intended location in all cases. Following suture tethering, variable degrees of MR were obtained. At gross anatomy, the neochordae were positioned at 1-4mm from the leaflet free edge, and were firmly attached to the leaflets. Transcatheter endovascular neochordae implantation is feasible. A prolapse model is needed to further demonstrate feasibility under pathologic conditions. The apical approach allows easy and direct route to transcatheter beating heart minimally invasive mitral repair.

  15. Design of a Cyclic Pressure Bioreactor for the Ex Vivo Study of Aortic Heart Valves

    PubMed Central

    Schipke, Kimberly J.; Filip To, S. D.; Warnock, James N.

    2011-01-01

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage1-3. Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease4. The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve5. Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves6-9. Pulsatile bioreactors have also been developed to study a range of tissues including cartilage10, bone11 and bladder12. The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the

  16. Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.

    PubMed

    Schipke, Kimberly J; To, S D Filip; Warnock, James N

    2011-08-23

    The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed

  17. An immersogeometric variational framework for fluid–structure interaction: application to bioprosthetic heart valves

    PubMed Central

    Kamensky, David; Hsu, Ming-Chen; Schillinger, Dominik; Evans, John A.; Aggarwal, Ankush; Bazilevs, Yuri; Sacks, Michael S.; Hughes, Thomas J. R.

    2014-01-01

    In this paper, we develop a geometrically flexible technique for computational fluid–structure interaction (FSI). The motivating application is the simulation of tri-leaflet bioprosthetic heart valve function over the complete cardiac cycle. Due to the complex motion of the heart valve leaflets, the fluid domain undergoes large deformations, including changes of topology. The proposed method directly analyzes a spline-based surface representation of the structure by immersing it into a non-boundary-fitted discretization of the surrounding fluid domain. This places our method within an emerging class of computational techniques that aim to capture geometry on non-boundary-fitted analysis meshes. We introduce the term “immersogeometric analysis” to identify this paradigm. The framework starts with an augmented Lagrangian formulation for FSI that enforces kinematic constraints with a combination of Lagrange multipliers and penalty forces. For immersed volumetric objects, we formally eliminate the multiplier field by substituting a fluid–structure interface traction, arriving at Nitsche’s method for enforcing Dirichlet boundary conditions on object surfaces. For immersed thin shell structures modeled geometrically as surfaces, the tractions from opposite sides cancel due to the continuity of the background fluid solution space, leaving a penalty method. Application to a bioprosthetic heart valve, where there is a large pressure jump across the leaflets, reveals shortcomings of the penalty approach. To counteract steep pressure gradients through the structure without the conditioning problems that accompany strong penalty forces, we resurrect the Lagrange multiplier field. Further, since the fluid discretization is not tailored to the structure geometry, there is a significant error in the approximation of pressure discontinuities across the shell. This error becomes especially troublesome in residual-based stabilized methods for incompressible flow, leading

  18. Doctors and pharmacists provision and opinions of medicines information leaflets in New Zealand.

    PubMed

    Young, Amber; Tordoff, June; Leitch, Sharon; Smith, Alesha

    2018-06-01

    Background Providing verbal medicines information to patients may be insufficient. Providing medicine information leaflets could support verbal information, however New Zealand health professionals' opinions or use of leaflets is unknown. Objective To examine self-reported provision and health professionals' views about medicine information leaflets and to determine their support for tailoring patient leaflets. Setting A cross sectional survey of general practitioners (GPs) and community pharmacists in New Zealand primary care. Method GPs and pharmacists completed validated questionnaires. Data was collected using SurveyMonkey® and where applicable, Chi squared analysis was carried out. Main outcome measures Frequency of leaflet provision, how leaflets are used in practice and why, likes and dislikes of available leaflets, and opinions on providing tailored information. Results 143 GPs and 126 pharmacists responded. For new medicines, significantly more pharmacists than GPs reported providing leaflets all or most of the time. For repeat medicines, leaflets were more likely to be given only on request. Leaflets were given to ensure patients are well-informed. Most GPs and pharmacists report discussing sections of leaflets with patients. The likes and dislikes of leaflets were mostly about design and content. Both professions support tailoring leaflets to meet individual's requirements. Conclusions Provision of medicines information needs to be re-evaluated. Relying on verbal communication is inadequate and leaflet provision appears to be suboptimal. Making leaflets more patient-centred and accessible could improve health professionals' perceptions and use of them. Automated creation and provision of tailored summary leaflets would be beneficial. Further advantage could be gained by digital patient access.

  19. Improving finite element results in modeling heart valve mechanics.

    PubMed

    Earl, Emily; Mohammadi, Hadi

    2018-06-01

    Finite element analysis is a well-established computational tool which can be used for the analysis of soft tissue mechanics. Due to the structural complexity of the leaflet tissue of the heart valve, the currently available finite element models do not adequately represent the leaflet tissue. A method of addressing this issue is to implement computationally expensive finite element models, characterized by precise constitutive models including high-order and high-density mesh techniques. In this study, we introduce a novel numerical technique that enhances the results obtained from coarse mesh finite element models to provide accuracy comparable to that of fine mesh finite element models while maintaining a relatively low computational cost. Introduced in this study is a method by which the computational expense required to solve linear and nonlinear constitutive models, commonly used in heart valve mechanics simulations, is reduced while continuing to account for large and infinitesimal deformations. This continuum model is developed based on the least square algorithm procedure coupled with the finite difference method adhering to the assumption that the components of the strain tensor are available at all nodes of the finite element mesh model. The suggested numerical technique is easy to implement, practically efficient, and requires less computational time compared to currently available commercial finite element packages such as ANSYS and/or ABAQUS.

  20. Observation of cavitation in a mechanical heart valve in a total artificial heart.

    PubMed

    Lee, Hwansung; Tsukiya, Tomonori; Homma, Akihiko; Kamimura, Tadayuki; Takewa, Yoshiaki; Nishinaka, Tomohiro; Tatsumi, Eisuke; Taenaka, Yoshiyuki; Takano, Hisateru; Kitamura, Soichiro

    2004-01-01

    Recently, cavitation on the surface of mechanical heart valves has been studied as a cause of fractures occurring in implanted mechanical heart valves. The cause of cavitation in mechanical heart valves was investigated using the 25 mm Medtronic Hall valve and the 23 mm Omnicarbon valve. Closing of these valves in the mitral position was simulated in an electrohydraulic totally artificial heart. Tests were conducted under physiologic pressures at heart rates from 60 to 100 beats per minute with cardiac outputs from 4.8 to 7.7 L/min. The disk closing motion was measured by a laser displacement sensor. A high-speed video camera was used to observe the cavitation bubbles in the mechanical heart valves. The maximum closing velocity of the Omnicarbon valve was faster than that of the Medtronic Hall valve. In both valves, the closing velocity of the leaflet, used as the cavitation threshold, was approximately 1.3-1.5 m/s. In the case of the Medtronic Hall valve, cavitation bubbles were generated by the squeeze flow and by the effects of the venturi and the water hammer. With the Omnicarbon valve, the cavitation bubbles were generated by the squeeze flow and the water hammer. The mechanism leading to the development of cavitation bubbles depended on the valve closing velocity and the valve stop geometry. Most of the cavitation bubbles were observed around the valve stop and were generated by the squeeze flow.

  1. Latent Tricuspid Valve Rupture after Motor Vehicle Accident and Routine Echocardiography in All Chest-Wall Traumas

    PubMed Central

    Khurana, Suchi; Puri, Rishi; Wong, Dennis; Dundon, Benjamin K.; Brown, Michael A.; Worthley, Matthew I.; Worthley, Stephen G.

    2009-01-01

    Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis. Herein, we report the case of a 42-year-old woman who sustained substantial chest-wall trauma in a high-speed motor vehicle accident. She presented a week later with symptoms of right-heart failure, secondary to flail tricuspid valve leaflets and torrential tricuspid regurgitation. The case of this patient highlights the importance of early diagnosis and elicits discussion of the mechanisms that can underlie delayed tricuspid valve rupture. Because the clinical diagnosis of tricuspid valve rupture can be difficult, we believe that echocardiography should be used early and, if necessary, repeatedly in all patients who sustain blunt chest-wall trauma. PMID:20069094

  2. Behavior of Bilayer Leaflets in Asymmetric Model Membranes: Atomistic Simulation Studies

    DOE PAGES

    Tian, Jianhui; Nickels, Jonathan; Katsaras, John; ...

    2016-04-27

    Spatial organization within lipid bilayers is an important feature for a range of biological processes. Leaflet compositional asymmetry and lateral lipid organization are just two of the ways in which membrane structure appears to be more complex than initially postulated by the fluid mosaic model. This raises the question of how the phase behavior in one bilayer leaflet may affect the apposing leaflet and how one begins to construct asymmetric model systems to investigate these interleaflet interactions. In this paper, we report on all-atom molecular dynamics simulations (a total of 4.1 μs) of symmetric and asymmetric bilayer systems composed ofmore » liquid-ordered (Lo) or liquid-disordered (Ld) leaflets, based on the nanodomain-forming POPC/DSPC/cholesterol system. We begin by analyzing an asymmetric bilayer with leaflets derived from simulations of symmetric Lo and Ld bilayers. In this system, we observe that the properties of the Lo and Ld leaflets are similar to those of the Lo and Ld leaflets in corresponding symmetric systems. However, it is not obvious that mixing the equilibrium structures of their symmetric counterparts is the most appropriate way to construct asymmetric bilayers nor that these structures will manifest interleaflet couplings that lead to domain registry/antiregistry. We therefore constructed and simulated four additional asymmetric bilayer systems by systematically adding or removing lipids in the Ld leaflet to mimic potential density fluctuations. We find that the number of lipids in the Ld leaflet affects its own properties, as well as those of the apposing Lo leaflet. Collectively, the simulations reveal the presence of weak acyl chain interdigitation across bilayer leaflets, suggesting that interdigitation alone does not contribute significantly to the interleaflet coupling in nonphase-separated bilayers of this chemical composition. Finally, however, the properties of both leaflets appear to be sensitive to changes in in

  3. Cardioscopic tricuspid valve repair in a beating ovine heart.

    PubMed

    Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y

    2009-04-01

    Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.

  4. Subject-specific finite-element modeling of normal aortic valve biomechanics from 3D+t TEE images.

    PubMed

    Labrosse, Michel R; Beller, Carsten J; Boodhwani, Munir; Hudson, Christopher; Sohmer, Benjamin

    2015-02-01

    In the past decades, developments in transesophageal echocardiography (TEE) have opened new horizons in reconstructive surgery of the aortic valve (AV), whereby corrections are made to normalize the geometry and function of the valve, and effectively treat leaks. To the best of our knowledge, we propose the first integrated framework to process subject-specific 3D+t TEE AV data, determine age-matched material properties for the aortic and leaflet tissues, build a finite element model of the unpressurized AV, and simulate the AV function throughout a cardiac cycle. For geometric reconstruction purposes, dedicated software was created to acquire the 3-D coordinates of 21 anatomical landmarks of the AV apparatus in a systematic fashion. Measurements from ten 3D+t TEE datasets of normal AVs were assessed for inter- and intra-observer variability. These tests demonstrated mean measurement errors well within the acceptable range. Simulation of a complete cardiac cycle was successful for all ten valves and validated the novel schemes introduced to evaluate age-matched material properties and iteratively scale the unpressurized dimensions of the valves such that, given the determined material properties, the dimensions measured in vivo closely matched those simulated in late diastole. The leaflet coaptation area, describing the quality of the sealing of the valve, was measured directly from the medical images and was also obtained from the simulations; both approaches correlated well. The mechanical stress values obtained from the simulations may be interpreted in a comparative sense whereby higher values are indicative of higher risk of tearing and/or development of calcification. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.

    PubMed

    Chang, James D; Manning, Warren J; Ebrille, Elisa; Zimetbaum, Peter J

    2017-05-09

    The potential for cardiac implantable electronic device leads to interfere with tricuspid valve (TV) function has gained increasing recognition as having hemodynamic and clinical consequences associated with incremental morbidity and death. The diagnosis and treatment of lead-related (as distinct from functional) tricuspid regurgitation pose unique challenges. Because of pitfalls in routine diagnostic imaging, a high level of clinical suspicion must be maintained to avoid overlooking the possibility that worsening heart failure is a consequence of mechanical interference with TV leaflet mobility or coaptation and is amenable to lead extraction or valve repair or replacement. The future of cardiac implantable electronic devices includes pacing and perhaps defibrillation without a lead traversing the TV. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Rapid pannus formation after few months of obstructing aortic mechanical prosthesis.

    PubMed

    Al-Alao, Bassel; Simoniuk, Urszula; Heron, Brian; Parissis, Haralabos

    2015-11-01

    We report a rare case of a prosthetic aortic valve obstruction due to pannus formation only 3 months following aortic and mitral valve replacement. Fragments of asymmetrical pannus formation affected one of the leaflets of the bi-leaflet mechanical valve; the leaflet appeared immobile due to pannus ingrowth into the mechanical skeleton resulting in encroachment of the leaflet, which in turn became immobile. The patient successfully underwent emergency redo-aortic valve replacement.

  7. An assessment of nutritional information in oral health education leaflets.

    PubMed

    Morgan, M Z; McFarlane, E; Stewart, K F; Hunter, M L; Fairchild, R M

    2010-06-01

    Dental caries prevalence in UK children remains high and obesity, closely linked to Type 2 diabetes, is rising. Literature suggests that dentists may not give dietary advice due to a lack of clear and consistent guidelines. The aim of the study was to determine whether oral health education leaflets with a food and nutritional focus conform to existing UK national nutritional guidelines from the Department of Health (DoH), the Food Standards Agency (FSA) and the Committee on Medical Aspects of Food and Nutrition Policy (COMA). A sample of 30 information leaflets, aimed at parents and children aged 3-16 years, was sourced during the winter of 2005-2006. A qualitative content analysis was carried out to identify key recommendations on type, frequency and quantity of food and drink and general diet-related health advice. Most leaflets (21) promoted milk and water in agreement with nutritional guidelines. Timing of sugary food and drink to mealtimes (25) and decreasing frequency of 'sugary' e.g. non-milk extrinsic (NME) sugar containing foods (22) and drinks (25) reflected guidelines. Inconsistencies were, however, recorded in the leaflets. Five leaflets advised that frequency of consumption rather than the amount of sugary food or drink was important for oral health. This conflicts with nutritional guidelines, aimed at tackling obesity, to decrease both amount and frequency. There was conflicting advice on healthy snacks. Crisps were presented as 'healthy' by two leaflets; another two advised against snacking on dried fruit, conflicting with FSA guidelines that dried fruit contributes to "5 a day". Sixteen leaflets promoted cheese as 'healthy' with no limits on portion size; this could conflict with nutritional guidelines associated with percentage energy contribution of saturated fat to the diet. While there was agreement between leaflet content and nutritional guidelines, there were inconsistencies. Dental professionals should acknowledge these when selecting

  8. Early Transcatheter Aortic Valve Function With and Without Therapeutic Anticoagulation.

    PubMed

    Hiremath, Pranoti G; Kearney, Kathleen; Smith, Bryn; Don, Creighton; Dvir, Danny; Aldea, Gabriel; Reisman, Mark; McCabe, James M

    2017-11-01

    Prosthetic leaflet thrombosis is a growing concern in transcatheter aortic valve replacement (TAVR). Given the uncertainty of best practices for antiplatelet and anticoagulation therapies in the post-TAVR period, additional evidence regarding the impact of anticoagulation on prosthetic valve function after TAVR is needed. Patients undergoing native-valve TAVR at a single academic institution between 2012 and 2015 were analyzed based on any anticoagulant use at hospital discharge post TAVR. Changes in prosthetic valve peak velocity and mean gradient were assessed based on transthoracic echocardiograms performed immediately following valve implant and at 4-week follow-up. Multivariate regression analyses were performed to explore the impact of anticoagulation status on early TAVR valve performance. For 403 patients, there were no available data to analyze. Of those, 29.6% were discharged on anticoagulation. Following TAVR, the average mean prosthetic valve gradient was 11.8 ± 5.6 mm Hg and peak velocity was 2.33 ± 0.52 m/s. There were no significant differences between anticoagulated and non-anticoagulated groups in the mean or peak gradients or velocity immediately following implant or at 4 weeks, which remained true following multivariate adjustment (P=.80 for delta mean gradient; P=.91 for delta peak velocity). Our data suggest that the absence of anticoagulation is not associated with short-term degradation in TAVR performance and do not support the routine use of anticoagulation following native-valve TAVR.

  9. Advertising, expectations and informed consent: the contents and functions of acupuncture leaflets.

    PubMed

    Bishop, Felicity L; Salmon, Cathy

    2013-12-01

    To evaluate the content of patient information leaflets about acupuncture. 401 patient information leaflets were obtained from practising UK acupuncturists and subjected to content and thematic analysis. 59% of included leaflets were from NHS physiotherapists. Almost all the leaflets defined acupuncture and the majority explained how it might work, described the treatment process and placed it in a historical context. Most described possible benefits and risks of acupuncture and discussed contraindications and safety. Just under a third of leaflets (120, 30%) suggested conditions that might be helped by acupuncture, most commonly musculoskeletal pain, arthritis and injuries. By emphasising differences between individuals in acupuncture treatments and responsiveness, the leaflets fostered hope for positive effects without making any guarantees. Information leaflets are broadly consistent with the evidence for acupuncture, but some claims are inconsistent with official advice from advertising regulators. An ethically sound, scientifically grounded and psychologically effective leaflet should accurately convey both benefits and risks of treatment, optimise patients' expectations and allay concerns about needling. This study suggests that acupuncture leaflets might achieve these multiple functions but care should be taken to ensure adequate coverage of risks.

  10. Increased dietary intake of vitamin A promotes aortic valve calcification in vivo.

    PubMed

    Huk, Danielle J; Hammond, Harriet L; Kegechika, Hiroyuki; Lincoln, Joy

    2013-02-01

    Calcific aortic valve disease (CAVD) is a major public health problem with no effective treatment available other than surgery. We previously showed that mature heart valves calcify in response to retinoic acid (RA) treatment through downregulation of the SRY transcription factor Sox9. In this study, we investigated the effects of excess vitamin A and its metabolite RA on heart valve structure and function in vivo and examined the molecular mechanisms of RA signaling during the calcification process in vitro. Using a combination of approaches, we defined calcific aortic valve disease pathogenesis in mice fed 200 IU/g and 20 IU/g of retinyl palmitate for 12 months at molecular, cellular, and functional levels. We show that mice fed excess vitamin A develop aortic valve stenosis and leaflet calcification associated with increased expression of osteogenic genes and decreased expression of cartilaginous markers. Using a pharmacological approach, we show that RA-mediated Sox9 repression and calcification is regulated by classical RA signaling and requires both RA and retinoid X receptors. Our studies demonstrate that excess vitamin A dietary intake promotes heart valve calcification in vivo. Therefore suggesting that hypervitaminosis A could serve as a new risk factor of calcific aortic valve disease in the human population.

  11. Insufficient Leaflet Remodeling in Patients With Atrial Fibrillation: Association With the Severity of Mitral Regurgitation.

    PubMed

    Kagiyama, Nobuyuki; Hayashida, Akihiro; Toki, Misako; Fukuda, Shota; Ohara, Minako; Hirohata, Atsushi; Yamamoto, Keizo; Isobe, Mitsuaki; Yoshida, Kiyoshi

    2017-03-01

    The relationship between annular dilatation caused by atrial fibrillation (AF) and mitral regurgitation (MR) remains controversial. We hypothesized that the small ratio of total leaflet area/annulus area (TLA/AA), reflecting insufficient leaflet remodeling to annular dilatation, is a main component of MR in patients with AF. Three-dimensional transesophageal echocardiographic data of the mitral valve were analyzed in 28 AF patients with moderate or severe MR (MR group), age- and sex-matched 56 AF patients with mild or less MR (non-MR group), and 16 control subjects. AA was significantly greater in both the MR (645±126 mm 2 /m 2 , P <0.001) and non-MR groups (568±121 mm 2 /m 2 , P =0.001) compared with control subjects (444±108 mm 2 /m 2 ). However, TLA/AA was significantly smaller in the MR (1.29±0.10, P <0.001), but not in the non-MR group (1.65±0.24, P >0.99), compared with control subjects (1.70±0.29). In linear regression analysis, TLA/AA was inversely associated with the effective regurgitant orifice ( r =-0.73, P <0.001). The area under the receiver-operating-characteristics curve of TLA/AA was significantly greater than that of AA (0.95 versus 0.72, P <0.001). Multivariable analysis revealed that small TLA/AA ( P <0.001) was independently associated with significant MR, while AA was not ( P =0.26). In patients with AF, insufficient leaflet remodeling to annular dilatation, rather than crude annular dilatation, was strongly associated with the severity of MR. © 2017 American Heart Association, Inc.

  12. Antiphospholipid antibody-associated non-infective mitral valve endocarditis successfully treated with medical therapy.

    PubMed

    Contractor, Tahmeed; Bell, Adrian; Khasnis, Atul; Silverberg, Bruce J; Martinez, Matthew W

    2013-01-01

    Non-bacterial endocarditis lesions associated with antiphospholipid antibodies (aPLs) in the absence of other criteria for antiphospholipid syndrome or systemic lupus erythematosus is termed an aPL-associated cardiac valve disease. Evidence regarding the management of this condition is sparse. A rare case is described of a 20-year-old female who presented with an incidental finding of 'vegetations on a heart valve'. Echocardiography revealed mitral valve leaflet thickening and echodensities with moderate mitral regurgitation. She had an elevated partial thromboplastin time that did not correct with a mixing study, and elevated levels of antiocardiolipin antibodies. Hence, a diagnosis of aPL-associated cardiac valve disease was made, and the patient commenced on warfarin, hydroxychloroquine, and a short course of oral prednisone. At one year after diagnosis the patient remained symptom-free, and follow up echocardiography revealed resolution of the vegetations with minimal mitral regurgitation. Further evidence is needed to guide the therapy of this rare condition.

  13. Adjunctive intracardiac echocardiography imaging from the left ventricle to guide percutaneous mitral valve repair with the MitraClip in patients with failed prior surgical rings.

    PubMed

    Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott

    2016-02-01

    We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.

  14. Characterization of three-dimensional anisotropic heart valve tissue mechanical properties using inverse finite element analysis.

    PubMed

    Abbasi, Mostafa; Barakat, Mohammed S; Vahidkhah, Koohyar; Azadani, Ali N

    2016-09-01

    Computational modeling has an important role in design and assessment of medical devices. In computational simulations, considering accurate constitutive models is of the utmost importance to capture mechanical response of soft tissue and biomedical materials under physiological loading conditions. Lack of comprehensive three-dimensional constitutive models for soft tissue limits the effectiveness of computational modeling in research and development of medical devices. The aim of this study was to use inverse finite element (FE) analysis to determine three-dimensional mechanical properties of bovine pericardial leaflets of a surgical bioprosthesis under dynamic loading condition. Using inverse parameter estimation, 3D anisotropic Fung model parameters were estimated for the leaflets. The FE simulations were validated using experimental in-vitro measurements, and the impact of different constitutive material models was investigated on leaflet stress distribution. The results of this study showed that the anisotropic Fung model accurately simulated the leaflet deformation and coaptation during valve opening and closing. During systole, the peak stress reached to 3.17MPa at the leaflet boundary while during diastole high stress regions were primarily observed in the commissures with the peak stress of 1.17MPa. In addition, the Rayleigh damping coefficient that was introduced to FE simulations to simulate viscous damping effects of surrounding fluid was determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Mechanism of valvular regurgitation.

    PubMed

    Khoo, Nee S; Smallhorn, Jeffery F

    2011-10-01

    Despite improvements in surgical techniques, valvular regurgitation results in major morbidity in children with heart disease. Functional anatomy, mechanisms of valve closure and adaptation to changing hemodynamic stress in normal mitral and tricuspid valves are complex and only partially understood. As well, pathology of atrioventricular valve regurgitation is further complicated by congenital valve abnormalities involving leaflet tissue, supporting chordal apparatus and displaced papillary muscles. This review provides a current understanding of the mechanisms that result in atrioventricular valve failure. Mitral valve leaflets have contractile elements, in addition to atrial muscle modulation of leaflet tension. When placed under mechanical tethering stress, the mitral valve adapts by leaflet expansion, which increases coaptation surface reserve and chordal thickening. Both pediatric and adult studies are increasingly reporting on the importance of subvalvar apparatus function in maintaining valve competency. The maintenance of efficient valve function is accomplished by a complex series of events involving atrial and annular contraction, annular deformation, active leaflet tension, chordal transmission of papillary muscle contractions and ventricular contraction.

  16. Tricuspid valve endocarditis

    PubMed Central

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  17. The 'respect rather than resect' principle in mitral valve repair: the lateral dislocation of the P2 technique.

    PubMed

    Zanobini, Marco; Ricciardi, Gabriella; Mammana, Francesco Liborio; Kassem, Samer; Poggio, Paolo; Di Minno, Alessandro; Cavallotti, L; Saccocci, Matteo

    2017-09-01

    Leaflet resection represents the reference standard for surgical treatment of mitral valve (MV) regurgitation. New approaches recently proposed place emphasis on respecting, rather than resecting, the leaflet tissue to avoid the drawbacks of the 'resection' approach. The lateral dislocation of mid portion of mitral posterior leaflet (P2) technique for MV repair is a nonresectional technique in which the prolapsed P2 segment is sutured to normal P1 segment. Our study evaluates the effectiveness of this technique. We performed the procedure on seven patients. Once ring annular sutures were placed, the prolapsed P2 segment was dislocated toward the normal P1 segment with a rotation of 90° and without any resection. If present, residual clefts between P2 and P3 segments were closed. Once the absence of residual mitral regurgitation is confirmed by saline pressure test, ring annuloplasty was completed. The valve was evaluated using transesophageal echocardiography in the operating room and by transthoracic echocardiography before discharge. At the last follow-up visit, transthoracic echocardiography revealed no mitral regurgitation and normal TRANSVALVULAR gradients. The lateral dislocation of P2 is an easily fine-tuned technique for isolated P2 prolapse, with the advantage of short aortic cross-clamp and cardiopulmonary bypass times. We think it might be very favorable in older and frail patients. Long-term follow-up is necessary to assess the durability of this technique.

  18. Pathological Investigation of Congenital Bicuspid Aortic Valve Stenosis, Compared with Atherosclerotic Tricuspid Aortic Valve Stenosis and Congenital Bicuspid Aortic Valve Regurgitation

    PubMed Central

    Hamatani, Yasuhiro; Ishibashi-Ueda, Hatsue; Nagai, Toshiyuki; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Fujita, Tomoyuki; Kobayashi, Junjiro; Anzai, Toshihisa

    2016-01-01

    Background Congenital bicuspid aortic valve (CBAV) is the main cause of aortic stenosis (AS) in young adults. However, the histopathological features of AS in patients with CBAV have not been fully investigated. Methods and Results We examined specimens of aortic valve leaflets obtained from patients who had undergone aortic valve re/placement at our institution for severe AS with CBAV (n = 24, CBAV-AS group), severe AS with tricuspid aortic valve (n = 24, TAV-AS group), and severe aortic regurgitation (AR) with CBAV (n = 24, CBAV-AR group). We compared the histopathological features among the three groups. Pathological features were classified using semi-quantitative methods (graded on a scale 0 to 3) by experienced pathologists without knowledge of the patients’ backgrounds. The severity of inflammation, neovascularization, and calcium and cholesterol deposition did not differ between the CBAV-AS and TAV-AS groups, and these four parameters were less marked in the CBAV-AR group than in the CBAV-AS (all p<0.01). Meanwhile, the grade of valvular fibrosis was greater in the CBAV-AS group, compared with the TAV-AS and CBAV-AR groups (both p<0.01). In AS patients, thickness of fibrotic lesions was greater on the aortic side than on the ventricular side (both p<0.01). Meanwhile, thickness of fibrotic lesions was comparable between the aortic and ventricular sides in CBAV-AR patients (p = 0.35). Conclusions Valvular fibrosis, especially on the aortic side, was greater in patients with CBAV-AS than in those without, suggesting a difference in the pathogenesis of AS between CBAV and TAV. PMID:27479126

  19. CorMatrix valved conduit in a porcine model: long-term remodelling and biomechanical characterization.

    PubMed

    Mosala Nezhad, Zahra; Poncelet, Alain; de Kerchove, Laurent; Fervaille, Caroline; Banse, Xavier; Bollen, Xavier; Dehoux, Jean-Paul; El Khoury, Gebrine; Gianello, Pierre

    2017-01-01

    Porcine small intestinal submucosa extracellular matrix (CorMatrix; CorMatrix Cardiovascular, Rosewell, GA) is a relatively novel tissue substitute used in cardiovascular applications. We investigated the biological reaction and remodelling of CorMatrix as a tri-leaflet valved conduit in a pig model. We hypothesized that CorMatrix maintains a durable architecture as a valved conduit and remodels to resemble surrounding tissues. We fashioned the valved conduit using a 7 × 10 cm 4-ply CorMatrix sheet and placed it in the thoracic aorta of seven landrace pigs for 3, 4, 5 and 6 months. Biodegradation, replacement by native tissue, strength and durability were examined by histology, immunohistochemistry and mechanical testing. Four pigs, one per time frame, completed the study. The conduit lost its original architecture as a tri-leaflet valve due to cusp immobility, subsequent attachment to the wall segment and consequent maintenance of a thick arterial wall-like structure. Scaffold resorption was incomplete, with disorganized inconsistent spatial and temporal degradation even at 6 months. Fibrosis, scarring and calcification started at 4 months and chronic inflammation persisted. The partially remodelled scaffold did not resemble the aortic wall, suggesting impaired remodelling. Mechanical testing showed progressive weakening of the tissues over time, which were liable to breakage. CorMatrix is biodegradable; however, it failed to remodel in a structured and anatomical fashion in an arterial environment. Progressive mechanical and remodelling failure in this scenario might be explained by the complexity of the conduit design and the host's chronic inflammatory response, leading to early fibrosis and calcification. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    PubMed

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  1. Tricuspid regurgitation after successful mitral valve surgery

    PubMed Central

    Katsi, Vasiliki; Raftopoulos, Leonidas; Aggeli, Constantina; Vlasseros, Ioannis; Felekos, Ioannis; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Kallikazaros, Ioannis

    2012-01-01

    The tricuspid valve (TV) is inseparably connected with the mitral valve (MV) in terms of function. Any pathophysiological condition concerning the MV is potentially a threat for the normal function of the TV as well. One of the most challenging cases is functional tricuspid regurgitation (TR) after surgical MV correction. In the past, TR was considered to progressively revert with time after left-sided valve restoration. Nevertheless, more recent studies showed that TR could develop and evolve postoperatively over time, as well as being closely associated with a poorer prognosis in terms of morbidity and mortality. Pressure and volume overload are usually the underlying pathophysiological mechanisms; structural alterations, like tricuspid annulus dilatation, increased leaflet tethering and right ventricular remodelling are almost always present when regurgitation develops. The most important risk factors associated with a higher probability of late TR development involve the elderly, female gender, larger left atrial size, atrial fibrillation, right chamber dilatation, higher pulmonary artery systolic pressures, longer times from the onset of MV disease to surgery, history of rheumatic heart disease, ischaemic heart disease and prosthetic valve malfunction. The time of TR manifestation can be up to 10 years or more after an MV surgery. Echocardiography, including the novel 3D Echo techniques, is crucial in the early diagnosis and prognosis of future TV disease development. Appropriate surgical technique and timing still need to be clarified. PMID:22457188

  2. Segmentation of the Aortic Valve Apparatus in 3D Echocardiographic Images: Deformable Modeling of a Branching Medial Structure

    PubMed Central

    Pouch, Alison M.; Tian, Sijie; Takabe, Manabu; Wang, Hongzhi; Yuan, Jiefu; Cheung, Albert T.; Jackson, Benjamin M.; Gorman, Joseph H.; Gorman, Robert C.; Yushkevich, Paul A.

    2015-01-01

    3D echocardiographic (3DE) imaging is a useful tool for assessing the complex geometry of the aortic valve apparatus. Segmentation of this structure in 3DE images is a challenging task that benefits from shape-guided deformable modeling methods, which enable inter-subject statistical shape comparison. Prior work demonstrates the efficacy of using continuous medial representation (cm-rep) as a shape descriptor for valve leaflets. However, its application to the entire aortic valve apparatus is limited since the structure has a branching medial geometry that cannot be explicitly parameterized in the original cm-rep framework. In this work, we show that the aortic valve apparatus can be accurately segmented using a new branching medial modeling paradigm. The segmentation method achieves a mean boundary displacement of 0.6 ± 0.1 mm (approximately one voxel) relative to manual segmentation on 11 3DE images of normal open aortic valves. This study demonstrates a promising approach for quantitative 3DE analysis of aortic valve morphology. PMID:26247062

  3. Diet and Colorectal Cancer Risk: Evaluation of a Nutrition Education Leaflet

    ERIC Educational Resources Information Center

    Dyer, K. J.; Fearon, K. C. H.; Buckner, K.; Richardson, R. A.

    2005-01-01

    Objective: To evaluate the effect of a needs-based, nutrition education leaflet on nutritional knowledge. Design: Comparison of nutritional knowledge levels before and after exposure to a nutrition education leaflet. Setting: A regional colorectal out-patient clinic in Edinburgh. Method: A nutrition education leaflet, based on an earlier…

  4. Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack

    PubMed Central

    Abbasi Teshnizi, Mohammad; Ghorbanzadeh, Atefeh; Zirak, Nahid; Manafi, Babak

    2017-01-01

    Cardiac calcified amorphous tumors (CATs) are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal. PMID:28194283

  5. Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack.

    PubMed

    Abbasi Teshnizi, Mohammad; Ghorbanzadeh, Atefeh; Zirak, Nahid; Manafi, Babak; Moeinipour, Aliasghar

    2017-01-01

    Cardiac calcified amorphous tumors (CATs) are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal.

  6. Tissue engineering of heart valves: in vitro experiences.

    PubMed

    Sodian, R; Hoerstrup, S P; Sperling, J S; Daebritz, S H; Martin, D P; Schoen, F J; Vacanti, J P; Mayer, J E

    2000-07-01

    Tissue engineering is a new approach, whereby techniques are being developed to transplant autologous cells onto biodegradable scaffolds to ultimately form new functional tissue in vitro and in vivo. Our laboratory has focused on the tissue engineering of heart valves, and we have fabricated a trileaflet heart valve scaffold from a biodegradable polymer, a polyhydroxyalkanoate. In this experiment we evaluated the suitability of this scaffold material as well as in vitro conditioning to create viable tissue for tissue engineering of a trileaflet heart valve. We constructed a biodegradable and biocompatible trileaflet heart valve scaffold from a porous polyhydroxyalkanoate (Meatabolix Inc, Cambridge, MA). The scaffold consisted of a cylindrical stent (1 x 15 x 20 mm inner diameter) and leaflets (0.3 mm thick), which were attached to the stent by thermal processing techniques. The porous heart valve scaffold (pore size 100 to 240 microm) was seeded with vascular cells grown and expanded from an ovine carotid artery and placed into a pulsatile flow bioreactor for 1, 4, and 8 days. Analysis of the engineered tissue included biochemical examination, enviromental scanning electron microscopy, and histology. It was possible to create a trileaflet heart valve scaffold from polyhydroxyalkanoate, which opened and closed synchronously in a pulsatile flow bioreactor. The cells grew into the pores and formed a confluent layer after incubation and pulsatile flow exposure. The cells were mostly viable and formed connective tissue between the inside and the outside of the porous heart valve scaffold. Additionally, we demonstrated cell proliferation (DNA assay) and the capacity to generate collagen as measured by hydroxyproline assay and movat-stained glycosaminoglycans under in vitro pulsatile flow conditions. Polyhydroxyalkanoates can be used to fabricate a porous, biodegradable heart valve scaffold. The cells appear to be viable and extracellular matrix formation was induced

  7. The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.

    PubMed

    Silaschi, Miriam; Conradi, Lenard; Wendler, Olaf; Schlingloff, Friederike; Kappert, Utz; Rastan, Ardawan J; Baumbach, Hardy; Holzhey, David; Eichinger, Walter; Bader, Ralf; Treede, Hendrik

    2018-06-01

    We present 1-year outcomes of the post-market registry of a next-generation transcatheter heart valve used for aortic regurgitation (AR). Transcatheter aortic valve replacement (TAVR) is routine in high-risk patients with aortic stenosis but is not recommended for AR. The JenaValve™ (JenaValve Technology GmbH, Munich, Germany) overcomes technical challenges in AR patients through a leaflet clipping mechanism. The JenaValve EvalUation of Long Term Performance and Safety In PaTients with SEvere Aortic Stenosis oR Aortic Insufficiency (JUPITER) Registry is a European study to evaluate safety and effectiveness of this THV. From 2012-2015, 30 patients with AR were enrolled. Mean age was 74.4 ± 9.3 years. Procedural success was 96.7% (29/30). One patient was converted to open surgery. No annular rupture or coronary ostia obstruction occurred. Mortality at 30 days was 10.0% (3/30). Combined safety endpoint was met in 13.3% (4/30). Paravalvular regurgitation was not present/trivial in 84.6% (22/26) and mild in 15.4% (4/26). Rate of permanent pacemaker implantation was 3.8% (1/26). One-year Kaplan-Meier survival was 79.9%, one-year combined efficacy was 73.1% (19/30). No further strokes were observed during 1 year of follow-up. The JenaValve overcomes technical challenges of TAVR in AR through a clipping mechanism. We report satisfactory outcomes of a multicenter registry using the JenaValve for predominant AR, as rate of THV embolization, residual AR and permanent pacemaker implantation was low. One-year results using the JenaValve for AR encourage its use for this indication. © 2017 Wiley Periodicals, Inc.

  8. The Ross operation: the autologous pulmonary valve in the aortic position.

    PubMed

    Gonzalez-Lavin, L; Robles, A; Graf, D

    1988-03-01

    Aortic valve replacement (AVR) with a pulmonary valve autograft (PVA) was first reported by Donald N. Ross (DNR) in 1967. The expectation of this procedure was to avoid degenerative changes seen in other biological tissue valves such as calcification, attenuation, and rupture of the leaflets. Recent reports by the original investigator's group have confirmed the lack of degenerative changes in PVA. To corroborate their conclusions, the fate of 12 patients undergoing AVR with PVA by one of us (LGL) has been ascertained. From March 1969 to June 1971, 12 patients underwent AVR with PVA. The right ventricular outflow tract (RVOT) was reconstructed with an aortic homograft valved conduit. The mean age was 42.7 years (range 21 to 52 years). The mean follow-up for 11 hospital survivors is 12.4 years. Three PVA have been replaced; one following infective endocarditis at 13 years, and two at 15 and 73 months due to technical malalignment. There was no evidence of PVA degeneration during histological examination of these explanted PVAs. Six patients are alive and retain the original PVA at 12 years (55%). This analysis corroborates the conclusions of the DNR report and strongly suggests an immunological mechanism in the process of calcification of other biological tissue valves. The Ross operation is advocated for AVR in young patients as valve durability is of paramount importance especially in this group.

  9. Effect of valsalva in the pulmonary prosthetic conduit valve on hemodynamic function in a mock circulatory system.

    PubMed

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Matsuo, Satoshi; Saiki, Yoshikatsu; Yamagishi, Masaaki

    2015-01-01

    Pulmonary conduit valves are used as one of the surgical treatment methods of congenital heart diseases. We have been designing a sophisticated pulmonary conduit valve for the right ventricular outflow tract reconstruction in pediatric patients. In this study, two types of polyester grafts with or without bulging structures for the conduit valves were used and evaluated from the hemodynamic point of view focusing on the application of these conduit valves in the grown-up congenital heart failure patients. We examined valvular function in the originally developed pulmonary mock circulatory system, which consisted of a pneumatic driven right ventricular model, a pulmonary valve chamber, and an elastic pulmonary compliance model with peripheral vascular resistance units. Prior to the measurement, a bileaflet valve was sutured in each conduit. Each conduit valve was installed in the mock right ventricular outflow portion, and its leaflet motion was obtained by using a high-speed camera synchronously with pressure and flow waveforms. As a result, we could obtain hemodynamic changes in two different types of conduits for pulmonary valves, and it was indicated that the presence of the Valsalva shape might be effective for promoting valvular response in the low cardiac output condition.

  10. New graft sizing rings for aortic valve reimplantation procedures.

    PubMed

    Jelenc, Matija; Jelenc, Blaž; Kneževic, Ivan; Klokocovnik, Tomislav

    2018-01-01

    The objective was to design sizing rings that would enable proper sizing of the graft in reimplantation procedures and to perform leaflet repair before graft implantation. The rings were designed in Autodesk Fusion 360 (San Rafael, CA, USA) and 3D printed using a commercial online 3D printing service. We designed incomplete rings with a low profile and complete rings with a high profile. The complete rings are best suited for reimplantation procedures, whereas low profile C rings are intended for isolated aortic valve repair, where the ascending aorta is not transected. The rings come in sizes corresponding to Vascutek Gelweave graft sizes (Vascutek Terumo, Renfrewshire, Scotland). The ring internal diameters are 5% larger than the designated ring sizes and account for the 5% stretch of the grafts when pressurized. Blades of the rings are placed at 20° intervals. The slits between the blades are designed in such a way that the commissural U-sutures, when put in place and under tension, will lock the ring in position. The rings were successfully used in 10 of our latest reimplantation procedures. After dissection of the aortic root, the commissures were suspended with U-stitches and then the ring was seated onto them. Complete leaflet repair with plication to achieve adequate effective height was then performed, followed by graft implantation. No additional leaflet repair was needed. The newly designed sizing rings enable proper sizing of the graft in reimplantation procedures and enable complete leaflet repair before graft implantation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. CD133 antibody conjugation to decellularized human heart valves intended for circulating cell capture.

    PubMed

    Vossler, John D; Min Ju, Young; Williams, J Koudy; Goldstein, Steven; Hamlin, James; Lee, Sang Jin; Yoo, James J; Atala, Anthony

    2015-09-03

    The long term efficacy of tissue based heart valve grafts may be limited by progressive degeneration characterized by immune mediated inflammation and calcification. To avoid this degeneration, decellularized heart valves with functionalized surfaces capable of rapid in vivo endothelialization have been developed. The aim of this study is to examine the capacity of CD133 antibody-conjugated valve tissue to capture circulating endothelial progenitor cells (EPCs). Decellularized human pulmonary valve tissue was conjugated with CD133 antibody at varying concentrations and exposed to CD133 expressing NTERA-2 cl.D1 (NT2) cells in a microflow chamber. The amount of CD133 antibody conjugated on the valve tissue surface and the number of NT2 cells captured in the presence of shear stress was measured. Both the amount of CD133 antibody conjugated to the valve leaflet surface and the number of adherent NT2 cells increased as the concentration of CD133 antibody present in the surface immobilization procedure increased. The data presented in this study support the hypothesis that the rate of CD133(+) cell adhesion in the presence of shear stress to decellularized heart valve tissue functionalized by CD133 antibody conjugation increases as the quantity of CD133 antibody conjugated to the tissue surface increases.

  12. Fluid-structure interaction in the left ventricle of the human heart coupled with mitral valve

    NASA Astrophysics Data System (ADS)

    Meschini, Valentina; de Tullio, Marco Donato; Querzoli, Giorgio; Verzicco, Roberto

    2016-11-01

    In this paper Direct Numerical Simulations (DNS), implemented using a fully fluid-structure interaction model for the left ventricle, the mitral valve and the flowing blood, and laboratory experiments are performed in order to cross validate the results. Moreover a parameter affecting the flow dynamics is the presence of a mitral valve. We model two cases, one with a natural mitral valve and another with a prosthetic mechanical one. Our aim is to understand their different effects on the flow inside the left ventricle in order to better investigate the process of valve replacement. We simulate two situations, one of a healthy left ventricle and another of a failing one. While in the first case the flow reaches the apex of the left ventricle and washout the stagnant fluid with both mechanical and natural valve, in the second case the disturbance generated by the mechanical leaflets destabilizes the mitral jet, thus further decreasing its capability to penetrate the ventricular region and originating heart attack or cardiac pathologies in general.

  13. The contents of dental implant patient information leaflets available within the UK.

    PubMed

    Barber, J; Puryer, J; McNally, L; O'Sullivan, D

    2015-02-01

    Patient information leaflets are designed to provide easy to follow information summaries and first point of contact information about treatment options. This survey reviewed the content of dental implant patient information leaflets, produced by implant companies and available within the UK in 2011. Dental implant companies in the UK were asked to provide samples of their patient information leaflets. The information within the leaflets was then summarised, including the quantity and the types of images used and whether the source of the information was given. Quantitative data was obtained on the amount of information provided, size of images and number of references. A response rate of 71% was obtained and 23 leaflets were studied. Great variation was found between the leaflets, with the word counts ranging from 88 to 5,434, and 44 different topics were identified. The majority of the images used were decorative, and none of the leaflets gave any reference to the sources of their information. Implant treatment was generally described in a positive way, with an emphasis on describing the treatment and the advantages. Much less information was given about the potential disadvantages and risks of complications or failure, including the relevance of periodontal disease or smoking. Implant patient information leaflets provided by dental implant companies should not be solely relied upon to provide patients with all the information they need to give informed consent to treatment.

  14. Crutches, confetti or useful tools? Professionals' views on and use of health education leaflets.

    PubMed

    Murphy, S; Smith, C

    1993-06-01

    This paper examines the views on and use of health education leaflets by a number of professional groups: health visitors, midwives, occupational health workers, pharmacists and school health education co-ordinators. Eighty nine percent currently obtain leaflets from health promotion units, with the exception of health visitors, professionals are largely satisfied with the units' service. Seventy six percent use commercial or sponsored leaflets primarily because of the large numbers and topics that are available. The numbers and type of leaflets used were found to vary across the professions. All professionals see an increasingly important role for leaflets in their work. A number of them, pharmacists and occupational health workers in particular, saw the numbers they use rising. These views were accompanied by lower levels of belief in a leaflets ability to increase knowledge and behaviour as well as lower levels of satisfaction with current leaflet use and a concern over the public's reception of leaflets. Methods of leaflet distribution to the public largely reflect the professionals' work contexts. Most popular were handing out leaflets with advice, leaving them in a public place and using them as a back-up to a meeting. A number of contradictions emerge between distribution practices and perceived effectiveness. Few professionals thought leaving leaflets in a public place was effective, and few health visitors and midwives believed giving leaflets to the family of a client was effective despite large numbers doing so. The implications of these findings for health promotion policy and practice are discussed.

  15. Meningioma of the superior leaflet of the velum interpositum: A case report

    PubMed Central

    Champagne, Pierre-Olivier; Bojanowski, Michel W.

    2015-01-01

    Background: Meningiomas of the velum interpositum in the roof of the third ventricle are rare. Knowing from which leaflet the meningioma originates and thus its relationships with the internal cerebral and Galen veins, may help in choosing the surgical approach. Case Description: We report the case of a 40-year-old male with a meningioma arising from the superior leaflet of the velum interpositum. The tumor was resected successfully using the infratentorial-supracerebellar approach. Reviewing the literature, of the 22 reported cases of velum interpositum meningiomas, sufficient information regarding the precise location of the origin of the tumor was provided in 14 cases, all of which were from the inferior leaflet. Conclusion: We report the first case of velum interpositum meningioma arising from the superior leaflet and give a potential explanation as to why meningiomas of the velum interpositum occur more commonly on the inferior leaflet. Distinguishing from which of the two leaflets the tumor originates may influence the surgical strategy. PMID:25949856

  16. Perforation of the right aortic valve cusp: complication of ventricular septal defect closure with a modified Rashkind umbrella.

    PubMed

    Vogel, M; Rigby, M L; Shore, D

    1996-01-01

    An 18-month-old boy with a perimembranous ventricular septal defect (VSD) had undergone transcatheter closure of the defect with a modified 17 mm Rashkind umbrella device at age 4 months (weight 3.8 kg). The clinical signs of a VSD persisted, and he developed aortic incompetence, first detected 5 months after the procedure, which progressed from mild to moderate. A three-dimensional echocardiographic study demonstrated that one of the four arms holding the umbrella was protruding into the aortic valve and had perforated the right aortic valve cusp. This diagnosis was confirmed at subsequent surgery. Surgical repair of the perforated right aortic valve leaflet was necessary. The umbrella was adherent to the tricuspid valve and could not be removed. Instead it was left in situ, but three of the stainless steel arms were cut off. When umbrella closure of a perimembranous VSD is undertaken, the close proximity of part of the distal umbrella to the aortic valve can lead to aortic regurgitation.

  17. Detection and quantification of angiogenesis in experimental valve disease with integrin-targeted nanoparticles and 19-fluorine MRI/MRS

    PubMed Central

    Waters, Emily A; Chen, Junjie; Allen, John S; Zhang, Huiying; Lanza, Gregory M; Wickline, Samuel A

    2008-01-01

    Background Angiogenesis is a critical early feature of atherosclerotic plaque development and may also feature prominently in the pathogenesis of aortic valve stenosis. It has been shown that MRI can detect and quantify specific molecules of interest expressed in cardiovascular disease and cancer by measuring the unique fluorine signature of appropriately targeted perfluorocarbon (PFC) nanoparticles. In this study, we demonstrated specific binding of ανβ3 integrin targeted nanoparticles to neovasculature in a rabbit model of aortic valve disease. We also showed that fluorine MRI could be used to detect and quantify the development of neovasculature in the excised aortic valve leaflets. Methods New Zealand White rabbits consumed a cholesterol diet for ~180 days and developed aortic valve thickening, inflammation, and angiogenesis mimicking early human aortic valve disease. Rabbits (n = 7) were treated with ανβ3 integrin targeted PFC nanoparticles or control untargeted PFC nanoparticles (n = 6). Competitive inhibition in vivo of nanoparticle binding (n = 4) was tested by pretreatment with targeted nonfluorinated nanoparticles followed 2 hours later by targeted PFC nanoparticles. 2 hours after treatment, aortic valves were excised and 19F MRS was performed at 11.7T. Integrated 19F spectral peaks were compared using a one-way ANOVA and Hsu's MCB (multiple comparisons with the best) post hoc t test. In 3 additional rabbits treated with ανβ3 integrin targeted PFC nanoparticles, 19F spectroscopy was performed on a 3.0T clinical scanner. The presence of angiogenesis was confirmed by immunohistochemistry. Results Valves of rabbits treated with targeted PFC nanoparticles had 220% more fluorine signal than valves of rabbits treated with untargeted PFC nanoparticles (p < 0.001). Pretreatment of rabbits with targeted oil-based nonsignaling nanoparticles reduced the fluorine signal by 42% due to competitive inhibition, to a level not significantly different from control

  18. After Superficial Ablation for Superficial Reflux Associated with Primary Deep Axial Reflux, Can Variable Outcomes be Caused by Deep Venous Valve Anomalies?

    PubMed

    Maleti, O; Lugli, M; Perrin, M

    2017-02-01

    To identify which deep anatomical anomalies can explain variable hemodynamic outcomes in patients with superficial reflux associated with primary deep axial reflux who underwent isolated superficial vein ablation without improvement. This is a retrospective study of deep venous valve anomalies in patients who underwent superficial vein ablation for superficial and associated deep reflux. A group of 21 patients who were diagnosed with saphenous reflux associated with primary deep axial reflux, were submitted to great saphenous vein ablation. In 17 patients the deep reflux was not abolished. In this subgroup, surgical exploration of the deep valve was carried out using venotomy for possible valve repair. Among the 17 subgroup patients, four post-thrombotic lesions were discovered intra-operatively in four patients; they underwent different surgical procedures. In 13 of the subgroup patients, primary valve incompetence was confirmed intra-operatively. In 11 cases the leaflets were asymmetrical and in only two were they symmetrical. After valvuloplasty, deep reflux was abolished in all 13 patients. Clinical improvement was obtained in 12/13 patients (92%). It is noteworthy that abolition of deep reflux was associated with significant improvement in air plethysmography data as well as with improvement in clinical status measured on CEAP class, VCSS and the SF-36 questionnaire. Failure to correct deep axial reflux by superficial ablation in patients with superficial and associated primary deep axial reflux may be related to asymmetry in the leaflets of the incompetent deep venous valve. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. [Parenting Renewal. Leaflet and Lessons for Parents of Adolescents.

    ERIC Educational Resources Information Center

    Clemson Univ., SC. Cooperative Extension Service.

    Instructional materials on parenting skills for parents of adolescents are provided, with teaching guides for extension service agents. Organized as a series of five leaflets followed by five corresponding lessons, leaflets for parents concern: (1) a review of parenting skills and an overview of the course of instruction; (2) evolution:…

  20. Calcification Characteristics of Low-Flow Low-Gradient Severe Aortic Stenosis in Patients Undergoing Transcatheter Aortic Valve Replacement

    PubMed Central

    Stähli, Barbara E.; Nguyen-Kim, Thi Dan Linh; Gebhard, Cathérine; Frauenfelder, Thomas; Tanner, Felix C.; Nietlispach, Fabian; Maisano, Francesco; Falk, Volkmar; Lüscher, Thomas F.; Maier, Willibald; Binder, Ronald K.

    2015-01-01

    Low-flow low-gradient severe aortic stenosis (LFLGAS) is associated with worse outcomes. Aortic valve calcification patterns of LFLGAS as compared to non-LFLGAS have not yet been thoroughly assessed. 137 patients undergoing transcatheter aortic valve replacement (TAVR) with preprocedural multidetector computed tomography (MDCT) and postprocedural transthoracic echocardiography were enrolled. Calcification characteristics were assessed by MDCT both for the total aortic valve and separately for each leaflet. 34 patients had LFLGAS and 103 non-LFLGAS. Total aortic valve calcification volume (p < 0.001), mass (p < 0.001), and density (p = 0.004) were lower in LFLGAS as compared to non-LFLGAS patients. At 30-day follow-up, mean transaortic pressure gradients and more than mild paravalvular regurgitation did not differ between groups. In conclusion, LFLGAS and non-LFLGAS express different calcification patterns which, however, did not impact on device success after TAVR. PMID:26435875

  1. Can the learning curve of totally endoscopic robotic mitral valve repair be short-circuited?

    PubMed

    Yaffee, David W; Loulmet, Didier F; Kelly, Lauren A; Ward, Alison F; Ursomanno, Patricia A; Rabinovich, Annette E; Neuburger, Peter J; Krishnan, Sandeep; Hill, Frederick T; Grossi, Eugene A

    2014-01-01

    A concern with the initiation of totally endoscopic robotic mitral valve repair (TERMR) programs has been the risk for the learning curve. To minimize this risk, we initiated a TERMR program with a defined team and structured learning approach before clinical implementation. A dedicated team (two surgeons, one cardiac anesthesiologist, one perfusionist, and two nurses) was trained with clinical scenarios, simulations, wet laboratories, and "expert" observation for 3 months. This team then performed a series of TERMRs of varying complexity. Thirty-two isolated TERMRs were performed during the first programmatic year. All operations included mitral valve repair, left atrial appendage exclusion, and annuloplasty device implantation. Additional procedures included leaflet resection, neochordae insertion, atrial ablation, and papillary muscle shortening. Longer clamp times were associated with number of neochordae (P < 0.01), papillary muscle procedures (P < 0.01), and leaflet resection (P = 0.06). Sequential case number had no impact on cross-clamp time (P = 0.3). Analysis of nonclamp time demonstrated a 71.3% learning percentage (P < 0.01; ie, 28.7% reduction in nonclamp time with each doubling of case number). There were no hospital deaths or incidences of stroke, myocardial infarction, unplanned reoperation, respiratory failure, or renal failure. Median length of stay was 4 days. All patients were discharged home. Totally endoscopic robotic mitral valve repair can be safely performed after a pretraining regimen with emphasis on experts' current practice and team training. After a pretraining regimen, cross-clamp times were not subject to learning curve phenomena but were dependent on procedural complexity. Nonclamp times were associated with a short learning curve.

  2. Chemical Composition and Antioxidant Activity of Euterpe oleracea Roots and Leaflets

    PubMed Central

    Brunschwig, Christel; Leba, Louis-Jérôme; Saout, Mona; Martial, Karine; Bereau, Didier; Robinson, Jean-Charles

    2016-01-01

    Euterpe oleracea (açaí) is a palm tree well known for the high antioxidant activity of its berries used as dietary supplements. Little is known about the biological activity and the composition of its vegetative organs. The objective of this study was to investigate the antioxidant activity of root and leaflet extracts of Euterpe oleracea (E. oleracea) and characterize their phytochemicals. E. oleracea roots and leaflets extracts were screened in different chemical antioxidant assays (DPPH—2,2-diphenyl-1-picrylhydrazyl, FRAP—ferric feducing antioxidant power, and ORAC—oxygen radical absorbance capacity), in a DNA nicking assay and in a cellular antioxidant activity assay. Their polyphenolic profiles were determined by UV and LC-MS/MS. E. oleracea leaflets had higher antioxidant activity than E. oleracea berries, and leaflets of Oenocarpus bacaba and Oenocarpus bataua, as well as similar antioxidant activity to green tea. E. oleracea leaflet extracts were more complex than root extracts, with fourteen compounds, including caffeoylquinic acids and C-glycosyl derivatives of apigenin and luteolin. In the roots, six caffeoylquinic and caffeoylshikimic acids were identified. Qualitative compositions of E. oleracea, Oenocarpus bacaba and Oenocarpus bataua leaflets were quite similar, whereas the quantitative compositions were quite different. These results provide new prospects for the valorization of roots and leaflets of E. oleracea in the pharmaceutical, food or cosmetic industry, as they are currently by-products of the açaí industry. PMID:28036089

  3. Chemical Composition and Antioxidant Activity of Euterpe oleracea Roots and Leaflets.

    PubMed

    Brunschwig, Christel; Leba, Louis-Jérôme; Saout, Mona; Martial, Karine; Bereau, Didier; Robinson, Jean-Charles

    2016-12-29

    Euterpe oleracea (açaí) is a palm tree well known for the high antioxidant activity of its berries used as dietary supplements. Little is known about the biological activity and the composition of its vegetative organs. The objective of this study was to investigate the antioxidant activity of root and leaflet extracts of Euterpe oleracea ( E . oleracea ) and characterize their phytochemicals. E . oleracea roots and leaflets extracts were screened in different chemical antioxidant assays (DPPH-2,2-diphenyl-1-picrylhydrazyl, FRAP-ferric feducing antioxidant power, and ORAC-oxygen radical absorbance capacity), in a DNA nicking assay and in a cellular antioxidant activity assay. Their polyphenolic profiles were determined by UV and LC-MS/MS. E . oleracea leaflets had higher antioxidant activity than E . oleracea berries, and leaflets of Oenocarpus bacaba and Oenocarpus bataua , as well as similar antioxidant activity to green tea. E. oleracea leaflet extracts were more complex than root extracts, with fourteen compounds, including caffeoylquinic acids and C -glycosyl derivatives of apigenin and luteolin. In the roots, six caffeoylquinic and caffeoylshikimic acids were identified. Qualitative compositions of E. oleracea , Oenocarpus bacaba and Oenocarpus bataua leaflets were quite similar, whereas the quantitative compositions were quite different. These results provide new prospects for the valorization of roots and leaflets of E. oleracea in the pharmaceutical, food or cosmetic industry, as they are currently by-products of the açaí industry.

  4. 3D velocity field characterization of prosthetic heart valve with two different valve testers by means of stereo-PIV.

    PubMed

    D'Avenio, Giuseppe; Grigioni, Mauro; Daniele, Carla; Morbiducci, Umberto; Hamilton, Kathrin

    2015-01-01

    Prosthetic heart valves can be associated to mechanical loading of blood, potentially linked to complications (hemolysis and thrombogenicity) which can be clinically relevant. In order to test such devices in pulsatile mode, pulse duplicators (PDs) have been designed and built according to different concepts. This study was carried out to compare anemometric measurements made on the same prosthetic device, with two widely used PDs. The valve (a 27-mm bileaflet valve) was mounted in the aortic section of the PD. The Sheffield University PD and the RWTH Aachen PD were selected as physical models of the circulation. These two PDs differ mainly in the vertical vs horizontal realization, and in the ventricular section, which in the RWTH PD allows for storage of potential energy in the elastic walls of the ventricle. A glassblown aorta, realized according to the geometric data of the same anatomical district in healthy individuals, was positioned downstream of the valve, obtaining 1:1 geometric similarity conditions. A NaI-glycerol-water solution of suitable kinematic viscosity and, at the same time, the proper refractive index, was selected. The flow field downstream of the valve was measured by means of the stereo-PIV (Particle Image Velocimetry) technique, capable of providing the complete 3D velocity field as well as the entire Reynolds stress tensor. The measurements were carried out at the plane intersecting the valve axis. A three-jet profile was clearly found in the plane crossing the leaflets, with both PDs. The extent of the typical recirculation zone in the Valsalva sinus was much larger in the RWTH PD, on account of the different duration of the swirling motion in the ventricular chamber, caused by the elasticity of the ventricle and its geometry. The comparison of the hemodynamical behaviour of the same bileaflet valve tested in two PDs demonstrated the role of the mock loop in affecting the valve performance.

  5. [Parenting Renewal. Leaflets and Lessons for Parents of Children Birth to Four.

    ERIC Educational Resources Information Center

    Clemson Univ., SC. Cooperative Extension Service.

    Instructional materials on parenting skills for parents of newborn through 4-year-old children are provided, with teaching guides for extension service agents. Organized as a series of nine leaflets followed by nine corresponding lessons, leaflets for parents concern: (1) an overview of the leaflets; (2) readiness: guiding normal development; (3)…

  6. The Relation Between Collagen Fibril Kinematics and Mechanical Properties in the Mitral Valve Anterior Leaflet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao,J.; Yang, L.; Grashow, J.

    2007-01-01

    We have recently demonstrated that the mitral valve anterior leaflet (MVAL) exhibited minimal hysteresis, no strain rate sensitivity, stress relaxation but not creep (Grashow et al., 2006, Ann Biomed Eng., 34(2), pp. 315-325; Grashow et al., 2006, Ann Biomed. Eng., 34(10), pp. 1509-1518). However, the underlying structural basis for this unique quasi-elastic mechanical behavior is presently unknown. As collagen is the major structural component of the MVAL, we investigated the relation between collagen fibril kinematics (rotation and stretch) and tissue-level mechanical properties in the MVAL under biaxial loading using small angle X-ray scattering. A novel device was developed and utilizedmore » to perform simultaneous measurements of tissue level forces and strain under a planar biaxial loading state. Collagen fibril D-period strain ({epsilon}{sub D}) and the fibrillar angular distribution were measured under equibiaxial tension, creep, and stress relaxation to a peak tension of 90 N/m. Results indicated that, under equibiaxial tension, collagen fibril straining did not initiate until the end of the nonlinear region of the tissue-level stress-strain curve. At higher tissue tension levels, {epsilon}{sub D} increased linearly with increasing tension. Changes in the angular distribution of the collagen fibrils mainly occurred in the tissue toe region. Using {epsilon}{sub D}, the tangent modulus of collagen fibrils was estimated to be 95.5{+-}25.5 MPa, which was {approx}27 times higher than the tissue tensile tangent modulus of 3.58{+-}1.83 MPa. In creep tests performed at 90 N/m equibiaxial tension for 60 min, both tissue strain and D remained constant with no observable changes over the test length. In contrast, in stress relaxation tests performed for 90 min {epsilon}{sub D} was found to rapidly decrease in the first 10 min followed by a slower decay rate for the remainder of the test. Using a single exponential model, the time constant for the reduction in

  7. Comparison of tricuspid and bicuspid aortic valve hemodynamics under steady flow conditions

    NASA Astrophysics Data System (ADS)

    Seaman, Clara; Ward, James; Sucosky, Philippe

    2011-11-01

    The bicuspid aortic valve (BAV), a congenital valvular defect consisting of two leaflets instead of three, is associated with a high prevalence of calcific aortic valve disease (CAVD). CAVD also develops in the normal tricuspid aortic valve (TAV) but its progression in the BAV is more severe and rapid. Although hemodynamic abnormalities are increasingly considered potential pathogenic contributor, the native BAV hemodynamics remain largely unknown. Therefore, this study aims at comparing experimentally the hemodynamic environments in TAV and BAV anatomies. Particle-image velocimetry was used to characterize the flow downstream of a native TAV and a model BAV mounted in a left-heart simulator and subjected to three steady flow rates characterizing different phases of the cardiac cycle. While the TAV developed a jet aligned along the valve axis, the BAV was shown to develop a skewed systolic jet with skewness decreasing with increasing flow rate. Measurement of the transvalvular pressure revealed a valvular resistance up to 50% larger in the BAV than in the TAV. The increase in velocity between the TAV and BAV leads to an increase in shear stress downstream of the valve. This study reveals strong hemodynamic abnormalities in the BAV, which may contribute to CAVD pathogenesis.

  8. Increased dietary intake of vitamin A promotes aortic valve calcification in vivo

    PubMed Central

    Huk, Danielle J.; Hammond, Harriet L.; Kegechika, Hiroyuki; Lincoln, Joy

    2013-01-01

    Objective Calcific aortic valve disease (CAVD) is a major public health problem with no effective treatment available other than surgery. We previously showed that mature heart valves calcify in response to retinoic acid (RA) treatment through downregulation of the SRY-transcription factor Sox9. In this study, we investigated the effects of excess vitamin A and its metabolite RA on heart valve structure and function in vivo, and examined the molecular mechanisms of RA signaling during the calcification process in vitro. Methods and Results Using a combination of approaches, we defined CAVD pathogenesis in mice fed 200 IU/g and 20 IU/g of retinyl palmitate for 12 months at molecular, cellular and functional levels. We show that mice fed excess vitamin A develop aortic valve stenosis and leaflet calcification associated with increased expression of osteogenic genes and decreased expression of cartilaginous markers. Using a pharmacological approach, we show that RA-mediated Sox9 repression and calcification is regulated by classical RA signaling and requires both RAR and RXR receptors. Conclusions Our studies demonstrate that excess vitamin A dietary intake promotes heart valve calcification in vivo. Therefore suggesting that hypervitaminosis A could serve as a new risk factor of CAVD in the human population. PMID:23202364

  9. Transapical off-pump mitral valve repair. First experience with the NeoChord system in Poland (report of two cases).

    PubMed

    Wróbel, Krzysztof; Kurnicka, Katarzyna; Zygier, Marcin; Dyk, Wojciech; Wojdyga, Ryszard; Zieliński, Dariusz; Jarzębska, Małgorzata; Juraszyński, Zbigniew; Lichodziejewska, Barbara; Pruszczyk, Piotr; Biederman, Andrzej; Speziali, Giovanni; Kasten, Uwe

    2017-01-01

    Artificial chord implantation to repair a flail or prolapsing mitral valve leaflet requires open heart surgery and cardiopulmonary bypass. Transapical off-pump artificial chordae implantation is a new surgical technique proposed to treat degenerative mitral valve regurgitation. The procedure is performed using the NeoChord DS1000 system (NeoChord, Inc., St. Louis Park, MN, USA), which facilitates both implantation and lenght adjustment of the artificial chordae under two (2D)- and three (3D)-dimensional transoesophageal echocardiographic (TEE) guidance on a beating heart. Two male patients aged 60 and 55 years with severe mitral regurgitation due to posterior leaflet prolapse underwent transapical off-pump artificial chordae implantation on September 3, 2015. The procedure was performed by left minithoracotomy under general anaesthesia in a cardiac surgical theatre, using 2D and 3D TEE guidance. Early procedural success as confirmed by 3D TEE was achieved in both patients, with implantation of 6 artificial chordae in the first patient and 3 artificial chordae in the second patient. Both procedures were uneventful, and no postoperative complications were noted. The patients were discharged home on the 8th and 6th postoperative day, respectively. The NeoChord DS1000 system allows both implantation and lenght adjustment of artificial chordae under 2D and 3D TEE guidance on a beating heart. Our initial experience in 2 patients with posterior mitral leaflet prolapse indicates that the procedure is feasible and safe.

  10. Readability of medicinal package leaflets: a systematic review.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords "Readability and Package Leaflet" and "Readability and Package Insert" in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results.

  11. Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy.

    PubMed

    Aquila, Iolanda; González, Ariana; Fernández-Golfín, Covadonga; Rincón, Luis Miguel; Casas, Eduardo; García, Ana; Hinojar, Rocio; Jiménez-Nacher, José Julio; Zamorano, José Luis

    2016-05-17

    3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable.

  12. Transcatheter valve implantation can alter fluid flow fields in aortic sinuses and ascending aorta

    NASA Astrophysics Data System (ADS)

    Saikrishnan, Neelakantan; Yoganathan, Ajit

    2012-11-01

    Transcatheter aortic valves (TAVs) are valve replacements used to treat aortic stenosis. Currently, these have been used in elderly patients at high-risk for open-heart procedures. Since these devices are implanted under fluoroscopic guidance, the implantation position of the valve can vary with respect to the native aortic valve annulus. The current study characterizes the altered hemodynamics in the aortic sinus and ascending aorta under different implantation (high and low) and cardiac output (2.5 and 5.0 L/min) conditions. Two commonly used TAV designs are studied using 2-D Particle Image Velocimetry (PIV). 200 phase locked images are obtained at every 25ms in the cardiac cycle, and the resulting vector fields are ensemble averaged. High implantation of the TAV with respect to the annulus causes weaker sinus washout and weaker sinus vortex formation. Additionally, the longer TAV leaflets can also result in a weaker sinus vortex. The level of turbulent fluctuations in the ascending aorta did not appear to be affected by axial positioning of the valve, but varied with cardiac output. The results of this study indicates that TAV positioning is important to be considered clinically, since this can affect coronary perfusion and potential flow stagnation near the valve.

  13. Spatiotemporal Segmentation and Modeling of the Mitral Valve in Real-Time 3D Echocardiographic Images.

    PubMed

    Pouch, Alison M; Aly, Ahmed H; Lai, Eric K; Yushkevich, Natalie; Stoffers, Rutger H; Gorman, Joseph H; Cheung, Albert T; Gorman, Joseph H; Gorman, Robert C; Yushkevich, Paul A

    2017-09-01

    Transesophageal echocardiography is the primary imaging modality for preoperative assessment of mitral valves with ischemic mitral regurgitation (IMR). While there are well known echocardiographic insights into the 3D morphology of mitral valves with IMR, such as annular dilation and leaflet tethering, less is understood about how quantification of valve dynamics can inform surgical treatment of IMR or predict short-term recurrence of the disease. As a step towards filling this knowledge gap, we present a novel framework for 4D segmentation and geometric modeling of the mitral valve in real-time 3D echocardiography (rt-3DE). The framework integrates multi-atlas label fusion and template-based medial modeling to generate quantitatively descriptive models of valve dynamics. The novelty of this work is that temporal consistency in the rt-3DE segmentations is enforced during both the segmentation and modeling stages with the use of groupwise label fusion and Kalman filtering. The algorithm is evaluated on rt-3DE data series from 10 patients: five with normal mitral valve morphology and five with severe IMR. In these 10 data series that total 207 individual 3DE images, each 3DE segmentation is validated against manual tracing and temporal consistency between segmentations is demonstrated. The ultimate goal is to generate accurate and consistent representations of valve dynamics that can both visually and quantitatively provide insight into normal and pathological valve function.

  14. Hemodynamics in an Aorta with Bicuspid and Trileaflet Valves

    NASA Astrophysics Data System (ADS)

    Gilmanov, Anvar; Sotiropoulos, Fotis

    2015-11-01

    Bicuspid aortic valve (BAV) is a congenital heart defect that has been associated with serious aortopathies, such as ascending aortic aneurysm, aortic stenosis, aortic regurgitation, infective endocarditis, aortic dissection, calcific aortic valve and dilatation of ascending aorta. Two main hypotheses - the genetic and the hemodynamic are discussed in literature to explain the development and progression of aortopathies in patients with BAV. In this study we seek to investigate the possible role of hemodynamic factors as causes of BAV-associated aortopathy. We employ the Curvilinear Immersed Boundary (CURVIB) method coupled with an efficient thin-shell finite element (TS-FE) formulation for tissues to carry out fluid-structure interaction simulations of a healthy tri-leaflet aortic valve (TAV) and a BAV placed in the same anatomic aorta. The computed results reveal major differences between the TAV and BAV flow patterns. These include: the dynamics of the aortic valve vortex ring formation and break up; the large scale flow patterns in the ascending aorta; and the shear stress magnitude on the aortic wall. The computed results are in qualitative agreement with in vivo Magnetic Resonance Imaging (MRI) data and suggest that the linkages between BAV aortopathy and hemodynamics deserve further investigation. This work is supported by the Lillehei Heart Institute at the University of Minnesota and the Minnesota Supercomputing Institute.

  15. Preparation, validation and user-testing of pictogram-based patient information leaflets for hemodialysis patients.

    PubMed

    Mateti, Uday Venkat; Nagappa, Anantha Naik; Attur, Ravindra Prabhu; Bairy, Manohar; Nagaraju, Shankar Prasad; Mallayasamy, Surulivelrajan; Vilakkathala, Rajesh; Guddattu, Vasudev; Balkrishnan, Rajesh

    2015-11-01

    Patient information leaflets are universally-accepted resources to educate the patients/users about their medications, disease and lifestyle modification. The objective of the study was to prepare, validate and perform user-testing of pictogram-based patient information leaflets (P-PILs) among hemodialysis (HD) patients. The P-PILs are prepared by referring to the primary, secondary and tertiary resources. The content and pictograms of the leaflet have been validated by an expert committee consisting of three nephrologists and two academic pharmacists. The Baker Able Leaflet Design has been applied to develop the layout and design of the P-PILs. Quasi-experimental pre- and post-test design without control group was conducted on 81 HD patients for user-testing of P-PILs. The mean Baker Able Leaflet Design assessment score for English version of the leaflet was 28, and 26 for Kannada version. The overall user-testing knowledge assessment mean scores were observed to have significantly improved from 44.25 to 69.62 with p value <0.001. The overall user opinion of content and legibility of the leaflets was good. Pictogram-based patient information leaflets can be considered an effective educational tool for HD patients.

  16. Anterior Leaflet Augmentation With CorMatrix Porcine Extracellular Matrix in Twenty-Five Patients: Unexpected Patch Failures and Histologic Analysis.

    PubMed

    Kelley, Thomas M; Kashem, Mohammed; Wang, He; McCarthy, James; Carroll, Nels D; Moser, G William; Guy, T Sloane

    2017-01-01

    This study reported on the treatment of Carpentier type IIIa and type IIIb mitral regurgitation (MR) with a large patch anterior mitral valve leaflet augmentation technique using CorMatrix (CorMatrix Cardiovascular Inc, Alpharetta, GA) extracellular matrix (ECM). A single-site chart review was conducted on patients who underwent anterior leaflet augmentation performed with the Da Vinci surgical robot (Intuitive Surgical, Sunnyvale, CA) or through a median sternotomy. Only patients who had anterior leaflet augmentation with porcine intestine ECM or autologous pericardium were included. Follow-up echocardiography was performed on all patients. Histologic specimens were available on ECM patches from a subset of patients who required reoperation. Between August 2011 and April 2014, 44 patients (mean age, 62.6 ± 12.2 years) underwent anterior leaflet augmentation with either porcine intestinal ECM or autologous pericardium at the Temple University Hospital in Philadelphia. Two (4%) late deaths occurred, one in each group. One patient who underwent ECM augmentation died of non-cardiac-related causes 7 months after discharge as a result of complications of chronic renal failure. The second late death occurred 5 months after discharge because of complications of a stroke in a patient in the pericardial augmentation group. Eight (32%) of the patients with ECM had recurrence of severe MR on echocardiography at an average time of 201 ± 98 days. Seven (28%) patients required reoperation because of failure of the ECM patch including perforation (4%), excessive patch dilation (20%), and suture line dehiscence (4%). In contrast, none of the patients with pericardial augmentation developed severe MR or required operation. Statistical analysis of the patients with ECM augmentation demonstrated no correlation of the following: age; sex; comorbid conditions such as diabetes, chronic obstructive pulmonary disease, and hypertension; left ventricular ejection fraction; surgical

  17. Rapid 3D printing of anatomically accurate and mechanically heterogeneous aortic valve hydrogel scaffolds

    PubMed Central

    Hockaday, L A; Kang, K H; Colangelo, N W; Cheung, P Y C; Duan, B; Malone, E; Wu, J; Girardi, L N; Bonassar, L J; Lipson, H; Chu, C C; Butcher, J T

    2013-01-01

    The aortic valve exhibits complex three-dimensional (3D) anatomy and heterogeneity essential for long-term efficient biomechanical function. These are, however, challenging to mimic in de novo engineered living tissue valve strategies. We present a novel simultaneous 3D-printing/photocrosslinking technique for rapidly engineering complex, heterogeneous aortic valve scaffolds. Native anatomic and axisymmetric aortic valve geometries (root wall and tri-leaflets) with 12 to 22 mm inner diameters (ID) were 3D printed with poly-ethylene glycol-diacrylate (PEG-DA) hydrogels (700 or 8000 MW) supplemented with alginate. 3D printing geometric accuracy was quantified and compared using Micro-CT. Porcine aortic valve interstitial cells (PAVIC) seeded scaffolds were cultured for up to 21 days. Results showed that blended PEG-DA scaffolds could achieve over 10-fold range in elastic modulus (5.3±0.9 to 74.6±1.5 kPa). 3D printing times for valve conduits with mechanically contrasting hydrogels were optimized to 14 to 45 minutes, increasing linearly with conduit diameter. Larger printed valves had greater shape fidelity (93.3±2.6, 85.1±2.0, and 73.3±5.2% for 22, 17, and 12 mm ID porcine valves; 89.1±4.0, 84.1±5.6, and 66.6±5.2% for simplified valves). PAVIC seeded scaffolds maintained near 100% viability over 21 days. These results demonstrate that 3D hydrogel printing with controlled photocrosslinking can rapidly fabricate anatomical heterogeneous valve conduits that support cell engraftment. PMID:22914604

  18. Adaptation of child oral health education leaflets for Arabic migrants in Australia: a qualitative study.

    PubMed

    Arora, Amit; Al-Salti, Ibrahim; Murad, Hussam; Tran, Quang; Itaoui, Rhonda; Bhole, Sameer; Ajwani, Shilpi; Jones, Charlotte; Manohar, Narendar

    2018-01-10

    The purpose of this study was to gain an in-depth understanding of Arabic-speaking mothers views on the usefulness of existing oral health education leaflets aimed at young children and also to record their views on the tailored versions of these leaflets. This qualitative study was nested within a large ongoing birth cohort study in South Western Sydney, Australia. Arabic-speaking mothers (n = 19) with young children were purposively selected and approached for a semi-structured interview. Two original English leaflets giving advice on young children's oral health were sent to mother's prior to the interview. On the day of interview, mothers were given simplified-English and Arabic versions of both the leaflets and were asked to compare the three versions. Interviews were audio-recorded, subsequently transcribed verbatim and analysed by thematic analysis. Ethical approval was obtained from Human Research Ethics Committees of the former Sydney South West Area Health Service, University of Sydney and Western Sydney University. Mothers reported that simplified English together with the Arabic version of the leaflets were useful sources of information. Although many mothers favoured the simplified version over original English leaflets, the majority favoured the leaflets in Arabic. Ideally, a "dual Arabic - simplified English leaflet" was preferred. The understanding of key health messages was optimised through a simple layout and visual images. There is a need to tailor oral health education leaflets for Arabic-speaking migrants. Producers of dental leaflets should also consider a "dual Arabic - simplified English leaflet" to improve oral health knowledge of Arabic-speaking migrants. The use of simple layout and pictures assists Arabic-speaking migrants to understand the content of dental leaflets.

  19. Scleraxis is required for cell lineage differentiation and extracellular matrix remodeling during murine heart valve formation in vivo.

    PubMed

    Levay, Agata K; Peacock, Jacqueline D; Lu, Yinhui; Koch, Manuel; Hinton, Robert B; Kadler, Karl E; Lincoln, Joy

    2008-10-24

    Heart valve structures, derived from mesenchyme precursor cells, are composed of differentiated cell types and extracellular matrix arranged to facilitate valve function. Scleraxis (scx) is a transcription factor required for tendon cell differentiation and matrix organization. This study identified high levels of scx expression in remodeling heart valve structures at embryonic day 15.5 through postnatal stages using scx-GFP reporter mice and determined the in vivo function using mice null for scx. Scx(-/-) mice display significantly thickened heart valve structures from embryonic day 17.5, and valves from mutant mice show alterations in valve precursor cell differentiation and matrix organization. This is indicated by decreased expression of the tendon-related collagen type XIV, increased expression of cartilage-associated genes including sox9, as well as persistent expression of mesenchyme cell markers including msx1 and snai1. In addition, ultrastructure analysis reveals disarray of extracellular matrix and collagen fiber organization within the valve leaflet. Thickened valve structures and increased expression of matrix remodeling genes characteristic of human heart valve disease are observed in juvenile scx(-/-) mice. In addition, excessive collagen deposition in annular structures within the atrioventricular junction is observed. Collectively, our studies have identified an in vivo requirement for scx during valvulogenesis and demonstrate its role in cell lineage differentiation and matrix distribution in remodeling valve structures.

  20. Medication information leaflets for patients: the further validation of an analytic linguistic framework.

    PubMed

    Clerehan, Rosemary; Hirsh, Di; Buchbinder, Rachelle

    2009-01-01

    While clinicians may routinely use patient information leaflets about drug therapy, a poorly conceived leaflet has the potential to do harm. We previously developed a novel approach to analysing leaflets about a rheumatoid arthritis drug, using an analytic approach based on systemic functional linguistics. The aim of the present study was to verify the validity of the linguistic framework by applying it to two further arthritis drug leaflets. The findings confirmed the applicability of the framework and were used to refine it. A new stage or 'move' in the genre was identified. While the function of many of the moves appeared to be 'to instruct' the patient, the instruction was often unclear. The role relationships expressed in the text were critical to the meaning. As with our previous study, judged on their lexical density, the leaflets resembled academic text. The framework can provide specific tools to assess and produce medication information leaflets to support readers in taking medication. Future work could utilize the framework to evaluate information on other treatments and procedures or on healthcare information more widely.

  1. [Valvuloplasty with balloon catheter in biologic prosthesis. Reality or illusion].

    PubMed

    Ledesma Velasco, M; Verdín Vázquez, R; Acosta Valdez, J L; Munayer Calderón, J; Salgado Escobar, J L; Arias Monroy, L; Flores Mendoza, J

    1989-01-01

    We performed catheter balloon valvuloplasty (CBV) on 8 stenotic operatively-excised bioprosthetic valves (2 Hancock and 6 Ionescu Shiley). Pathology of valves before CBV included degenerative changes: commissural fusion by mounds of calcific deposits (2 valves), fibrotic and focally calcified leaflets (7 valves) and stiff and thick valves (1 valve). Inflation of the balloon resulted in commissural splitting (2 valves), leaflet cracks and fractures (3 valves). Removal of the deflated balloon catheter was associated with debris dislodgement (3 valves). In one case the valve was unable to close with potential for acute regurgitation. Thus, CBV of bioprosthetic valves can split fused commissures by similar mechanisms as in native valves. CBV may fracture calcific deposits causing acute emboli. It can also disrupt the leaflets causing acute insufficiency. The findings suggest a limited role of CBV in the treatment of stenotic bioprosthetic valves in mitral and aortic position.

  2. 4D optical coherence tomography of aortic valve dynamics in a murine mouse model ex vivo

    NASA Astrophysics Data System (ADS)

    Schnabel, Christian; Jannasch, Anett; Faak, Saskia; Waldow, Thomas; Koch, Edmund

    2015-07-01

    The heart and its mechanical components, especially the heart valves and leaflets, are under enormous strain during lifetime. Like all highly stressed materials, also these biological components undergo fatigue and signs of wear, which impinge upon cardiac output and in the end on health and living comfort of affected patients. Thereby pathophysiological changes of the aortic valve leading to calcific aortic valve stenosis (AVS) as most frequent heart valve disease in humans are of particular interest. The knowledge about changes of the dynamic behavior during the course of this disease and the possibility of early stage diagnosis could lead to the development of new treatment strategies and drug-based options of prevention or therapy. ApoE-/- mice as established model of AVS versus wildtype mice were introduced in an ex vivo artificially stimulated heart model. 4D optical coherence tomography (OCT) in combination with high-speed video microscopy were applied to characterize dynamic behavior of the murine aortic valve and to characterize dynamic properties during artificial stimulation. OCT and high-speed video microscopy with high spatial and temporal resolution represent promising tools for the investigation of dynamic behavior and their changes in calcific aortic stenosis disease models in mice.

  3. Supravalvar mitral ring with a parachute mitral valve and subcoarctation of the aorta in a child with hemodynamically significant VSD. A study of the morphology, echocardiographic diagnostics and surgical therapy.

    PubMed

    Mądry, Wojciech; Karolczak, Maciej A; Grabowski, Krzysztof

    2017-09-01

    The authors present a case of echocardiographic diagnosis of supravalvar mitral ring (a fibromembranous structure that arose from the atrial surface of the mitral leaflets) in a child with a parachute mitral valve, a ventricular septal defect, and mild narrowing of the aortic isthmus. The supravalvar mitral stenosis is a typical but very infrequently detected element of the complex of anatomical abnormalities located within the left heart and the proximal aorta, called the Shone's complex (syndrome). Diagnosing an additional, hemodynamically significant anatomic defect during echocardiography was possible thanks to the detection of marked mobility limitation of the ring-adjacent part of the mitral valve mural leaflet as well as of an atypical image of turbulence occurring during the inflow from the left atrium to the left ventricle. The early diagnosis made it possible to perform complete correction of this complex congenital defect within a single operation.

  4. Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients

    PubMed Central

    Ma, Wei-Guo; Hou, Bin; Abdurusul, Adiljan; Gong, Ding-Xu; Tang, Yue; Chang, Qian; Xu, Jian-Ping

    2015-01-01

    Background Dysfunction of mechanical heart valve prostheses is an unusual but potentially lethal complication after mechanical prosthetic valve replacement. We seek to report our experience with mechanical valve dysfunction regarding etiology, surgical techniques and early outcomes. Methods Clinical data of 48 patients with mechanical valve dysfunction surgically treated between October 1996 and June 2011 were analyzed. Results Mean age was 43.7±10.9 years and 34 were female (70.8%). The median interval from primary valve implantation to dysfunction was 44.5 months (range, 1 hour to 20 years). There were 21 emergent and 27 elective reoperations. The etiology was thrombosis in 19 cases (39.6%), pannus in 12 (25%), thrombosis and pannus in 11 (22.9%), improper disc orientation in 2 (4.1%), missing leaflet in 1 (2.1%), excessively long knot end in 1 (2.1%), endogenous factor in 1 (2.1%) and unidentified in 1 (2.1%). Surgical procedure was mechanical valve replacement in 37 cases (77.1%), bioprosthetic valve replacement in 7 (14.9%), disc rotation in 2 (4.2%) and excision of excessive knot end in 1 (2.1%). Early deaths occurred in 7 patients (14.6%), due to low cardiac output in 3 (6.3%), multi-organ failure in 2 (4.2%) and refractory ventricular fibrillation in 2 (4.2%). Complications occurred in 10 patients (20.8%). Conclusions Surgical management of mechanical valve dysfunction is associated with significant mortality and morbidity. Earlier identification and prompt reoperation are vital to achieving better clinical outcomes. The high incidence of thrombosis in this series highlights the need for adequate anticoagulation and regular follow-up after mechanical valve replacement. PMID:26793354

  5. Retained structural integrity of collagen and elastin within cryopreserved human heart valve tissue as detected by two-photon laser scanning confocal microscopy.

    PubMed

    Gerson, Cindy J; Goldstein, Steven; Heacox, Albert E

    2009-10-01

    Cryopreservation is commonly used for the long-term storage of heart valve allografts. Despite the excellent hemodynamic performance and durability of cryopreserved allografts, reports have questioned whether cryopreservation affects the valvular structural proteins, collagen and elastin. This study uses two-photon laser scanning confocal microscopy (LSCM) to evaluate the effect of cryopreservation on collagen and elastin integrity within the leaflet and conduit of aortic and pulmonary human heart valves. To permit pairwise comparisons of fresh and cryopreserved tissue, test valves were bisected longitudinally with one segment imaged fresh and the other imaged after cryopreservation and brief storage in liquid nitrogen. Collagen was detected by second harmonic generation (SHG) stimulation and elastin by autofluorescence excitation. Qualitative analysis of all resultant images indicated the maintenance of collagen and elastin structure within leaflet and conduit post-cryopreservation. Analysis of the optimized percent laser transmission (OPLT) required for full dynamic range imaging of collagen and elastin showed that OPLT observations were highly variable among both fresh and cryopreserved samples. Changes in donor-specific average OPLT in response to cryopreservation exhibited no consistent directional trend. The donor-aggregated results predominantly showed no statistically significant change in collagen and elastin average OPLT due to cryopreservation. Since OPLT has an inverse relationship with structural signal intensity, these results indicate that there was largely no statistical difference in collagen and elastin signal strength between fresh and cryopreserved tissue. Overall, this study indicates that the conventional cryopreservation of human heart valve allografts does not detrimentally affect their collagen and elastin structural integrity.

  6. Patient assessment of medication information leaflets and validation of the Evaluative Linguistic Framework (ELF).

    PubMed

    Hirsh, Di; Clerehan, Rosemary; Staples, Margaret; Osborne, Richard H; Buchbinder, Rachelle

    2009-11-01

    To obtain patient feedback about the structure and quality of medication information leaflets and validate the usefulness of the Evaluative Linguistic Framework (ELF) for improving written communication with patients. Triangulated feedback about a set of rheumatoid arthritis (RA) medication leaflets, some developed with knowledge of the ELF, was obtained from 27 people with RA from interviews, focus group discussion and self-administered questionnaires. The principal elements of the framework were investigated: overall generic structure and functions of each stage, interpersonal relationship between writer and reader, technicality of language and density of information. Participant assessments of the leaflets aligned with the framework in terms of what constituted a good leaflet. While the main purpose of the leaflets was identified as being information provision, participants also wanted clear instructions, benefits to be highlighted and side effects to be comprehensively listed. For comprehensiveness and user-friendliness, leaflets developed with guidance of the ELF were consistently preferred. According to people with RA, leaflets generated from a linguistic framework are clearer and more effective in communicating information about medications. The ELF is a user-friendly, structured analytic system that can assist with the development of effective high quality patient information materials.

  7. TexMi: Development of Tissue-Engineered Textile-Reinforced Mitral Valve Prosthesis

    PubMed Central

    Moreira, Ricardo; Gesche, Valentine N.; Hurtado-Aguilar, Luis G.; Schmitz-Rode, Thomas; Frese, Julia

    2014-01-01

    Mitral valve regurgitation together with aortic stenosis is the most common valvular heart disease in Europe and North America. Mechanical and biological prostheses available for mitral valve replacement have significant limitations such as the need of a long-term anticoagulation therapy and failure by calcifications. Both types are unable to remodel, self-repair, and adapt to the changing hemodynamic conditions. Moreover, they are mostly designed for the aortic position and do not reproduce the native annular-ventricular continuity, resulting in suboptimal hemodynamics, limited durability, and gradually decreasing ventricular pumping efficiency. A tissue-engineered heart valve specifically designed for the mitral position has the potential to overcome the limitations of the commercially available substitutes. For this purpose, we developed the TexMi, a living textile-reinforced mitral valve, which recapitulates the key elements of the native one: annulus, asymmetric leaflets (anterior and posterior), and chordae tendineae to maintain the native annular-ventricular continuity. The tissue-engineered valve is based on a composite scaffold consisting of the fibrin gel as a cell carrier and a textile tubular structure with the twofold task of defining the gross three-dimensional (3D) geometry of the valve and conferring mechanical stability. The TexMi valves were molded with ovine umbilical vein cells and stimulated under dynamic conditions for 21 days in a custom-made bioreactor. Histological and immunohistological stainings showed remarkable tissue development with abundant aligned collagen fibers and elastin deposition. No cell-mediated tissue contraction occurred. This study presents the proof-of-principle for the realization of a tissue-engineered mitral valve with a simple and reliable injection molding process readily adaptable to the patient's anatomy and pathological situation by producing a patient-specific rapid prototyped mold. PMID:24665896

  8. Transapical implantation of a second-generation transcatheter heart valve in patients with noncalcified aortic regurgitation.

    PubMed

    Seiffert, Moritz; Diemert, Patrick; Koschyk, Dietmar; Schirmer, Johannes; Conradi, Lenard; Schnabel, Renate; Blankenberg, Stefan; Reichenspurner, Hermann; Baldus, Stephan; Treede, Hendrik

    2013-06-01

    This study sought to report on the feasibility and early results of transcatheter aortic valve implantation employing a second-generation device in a series of patients with pure aortic regurgitation. Efficacy and safety of transcatheter aortic valve implantation in patients with calcific aortic stenosis and high surgical risk has been demonstrated. However, experience with implantation for severe noncalcified aortic regurgitation has been limited due to increased risk for valve dislocation or annular rupture. Five patients (mean age: 66.6 ± 7 years) underwent transapical implantation of a JenaValve (JenaValve Technology GmbH, Munich, Germany) transcatheter heart valve for moderate to severe, noncalcified aortic regurgitation. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team (logistic EuroSCORE [European System for Cardiac Operative Risk Evaluation] range 3.1% to 38.9%). Procedural and acute clinical outcomes were analyzed. Implantation was successful in all cases without relevant remaining aortic regurgitation or signs of stenosis in any of the patients. No major device- or procedure-related adverse events occurred and all 5 patients were alive with improved exercise tolerance at 3-month follow-up. Noncalcified aortic regurgitation continues to be a challenging pathology for transcatheter aortic valve implantation due to the risk for insufficient anchoring of the valve stent within the aortic annulus. This report provides first evidence that the JenaValve prosthesis may be a reasonable option in these specific patients due to its unique stent design, clipping the native aortic valve leaflets, and offering promising early results. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valves.

    PubMed

    Knierbein, B; Rosarius, N; Unger, A; Reul, H; Rau, G

    1992-07-01

    The computer-supported development of valves for cardiac-assist devices or artificial hearts is shown in relation to plastic technology. A CAD-system is used for the design development, whereas the dimensioning of the critical and highly stressed membranes is examined by FEM-analyses. Economic manufacture is permitted by the combined thermoforming-dip moulding technique; the blood-side components are made from biocompatible polyurethane to minimize blood damage. The first long-term results in the test set-up are compared to the FEM results.

  10. New Pulmonary Valvuloplasty Technique by Use of an Hourglass-Shaped Balloon in 3 Adults with Severe Pulmonary Valve Stenosis

    PubMed Central

    Sahin, Tayfun; Karauzum, Kurtulus; Ural, Ertan; Pedersen, Wesley R.

    2018-01-01

    Percutaneous balloon pulmonary valvuloplasty is the preferred therapy for pulmonary valve stenosis. However, the designs of the cylindrical balloons historically used for valvuloplasty have limitations, especially in patients who have large pulmonary annular diameters. The hourglass-shaped V8 Aortic Valvuloplasty Balloon may prove to be an effective alternative. The balloon has 2 large bulbous segments that are separated by a narrowed waist. The geometric shape is maintained throughout inflation, improving fixation and enabling broader leaflet opening. We present our first experience with the V8 balloon in 3 adults who had severe, symptomatic pulmonary valve stenosis. In addition to describing their cases, we detail our sizing technique for pulmonary valvuloplasty with the V8 balloon. Our successful results suggest that the V8 balloon is efficient and safe for balloon pulmonary valvuloplasty in adults with severe pulmonary valve stenosis. PMID:29844739

  11. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    PubMed

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% <1 year); 86 (45%) had a preceding balloon valvuloplasty. The indications for the procedure were stenotic (n = 123; 64%), regurgitant (n = 63; 33%) or combined (n = 7; 4%) disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association

  12. Four decades of experience with mitral valve repair: analysis of differential indications, technical evolution, and long-term outcome.

    PubMed

    DiBardino, Daniel J; ElBardissi, Andrew W; McClure, R Scott; Razo-Vasquez, Ozwaldo A; Kelly, Nicole E; Cohn, Lawrence H

    2010-01-01

    To determine the long-term outcomes of mitral valvuloplasty for myxomatous valve disease, rheumatic valve disease, and functional mitral regurgitation. A total of 1503 patients underwent mitral valvuloplasty by a single surgeon between February 1972 and April 2008 and were retrospectively reviewed for short- and long-term results. Overall mean age was 60.3 + or - 13.7 years, and 57% were male. The cause was rheumatic in 193 patients, myxomatous in 1042 patients, and ischemic and nonischemic functional mitral regurgitation in 236 patients. Ring annuloplasty was performed in 1306 patients (87%). Commissurotomy was the primary repair for rheumatic valves, posterior leaflet resection and reconstruction was the most common repair for myxomatous valves (527/1042 [51%]), and ring reduction annuloplasty was the primary operation for functional mitral regurgitation. The 30-day mortality was 19 of 1503 patients (1.3%) and significantly higher in the functional mitral regurgitation group (11/236 patients, 4.7% vs 0.5% in the rheumatic group and 0.6% in the myxomatous group, P < .01). The 10-, 20-, and 30-year survivals were similar for the rheumatic and myxomatous groups (77%, 56%, and 39% vs 79%, 62%, and 52%, respectively) but significantly less for the functional mitral regurgitation group (44%, 4%, and 0%, respectively, log-rank P < .0001). The 10- and 20-year freedom from reoperation rates were significantly better for the myxomatous group than for the rheumatic group (90% and 82% vs 66% and 34%, log-rank P < .0001), with a 30-year freedom from reoperation of only 10% for rheumatic repair. In the myxomatous group, freedom from reoperation was lower in patients with anterior leaflet pathology (P = .0008). Follow-up data to 36 years demonstrate that cause strongly determines survival and durability of mitral valvuloplasty; patients with rheumatic valve disease who survive more than 20 years require reoperation, whereas functional mitral regurgitation carries the highest

  13. Promoting chlamydia screening with posters and leaflets in general practice--a qualitative study.

    PubMed

    Freeman, Elaine; Howell-Jones, Rebecca; Oliver, Isabel; Randall, Sarah; Ford-Young, William; Beckwith, Philippa; McNulty, Cliodna

    2009-10-12

    General practice staff are reluctant to discuss sexual health opportunistically in all consultations. Health promotion materials may help alleviate this barrier. Chlamydia screening promotion posters and leaflets, produced by the English National Chlamydia Screening Programme (NCSP), have been available to general practices, through local chlamydia screening offices, since its launch. In this study we explored the attitudes of general practice staff to these screening promotional materials, how they used them, and explored other promotional strategies to encourage chlamydia screening. Twenty-five general practices with a range of screening rates, were purposively selected from six NCSP areas in England. In focus groups doctors, nurses, administrative staff and receptionists were encouraged to discuss candidly their experiences about their use and opinions of posters, leaflets and advertising to promote chlamydia screening. Researchers observed whether posters and leaflets were on display in reception and/or waiting areas. Data were collected and analysed concurrently using a stepwise framework analytical approach. Although two-thirds of screening practices reported that they displayed posters and leaflets, they were not prominently displayed in most practices. Only a minority of practices reported actively using screening promotional materials on an ongoing basis. Most staff in all practices were not following up the advertising in posters and leaflets by routinely offering opportunistic screening to their target population. Some staff in many practices thought posters and leaflets would cause offence or embarrassment to their patients. Distribution of chlamydia leaflets by receptionists was thought to be inappropriate by some practices, as they thought patients would be offended when being offered a leaflet in a public area. Practice staff suggested the development of pocket-sized leaflets. The NCSP should consider developing a range of more discrete but eye

  14. Promoting chlamydia screening with posters and leaflets in general practice - a qualitative study

    PubMed Central

    Freeman, Elaine; Howell-Jones, Rebecca; Oliver, Isabel; Randall, Sarah; Ford-Young, William; Beckwith, Philippa; McNulty, Cliodna

    2009-01-01

    Background General practice staff are reluctant to discuss sexual health opportunistically in all consultations. Health promotion materials may help alleviate this barrier. Chlamydia screening promotion posters and leaflets, produced by the English National Chlamydia Screening Programme (NCSP), have been available to general practices, through local chlamydia screening offices, since its launch. In this study we explored the attitudes of general practice staff to these screening promotional materials, how they used them, and explored other promotional strategies to encourage chlamydia screening. Methods Twenty-five general practices with a range of screening rates, were purposively selected from six NCSP areas in England. In focus groups doctors, nurses, administrative staff and receptionists were encouraged to discuss candidly their experiences about their use and opinions of posters, leaflets and advertising to promote chlamydia screening. Researchers observed whether posters and leaflets were on display in reception and/or waiting areas. Data were collected and analysed concurrently using a stepwise framework analytical approach. Results Although two-thirds of screening practices reported that they displayed posters and leaflets, they were not prominently displayed in most practices. Only a minority of practices reported actively using screening promotional materials on an ongoing basis. Most staff in all practices were not following up the advertising in posters and leaflets by routinely offering opportunistic screening to their target population. Some staff in many practices thought posters and leaflets would cause offence or embarrassment to their patients. Distribution of chlamydia leaflets by receptionists was thought to be inappropriate by some practices, as they thought patients would be offended when being offered a leaflet in a public area. Practice staff suggested the development of pocket-sized leaflets. Conclusion The NCSP should consider developing

  15. [A philosophical information leaflet to accompany a DSM classification].

    PubMed

    Kraaijenbrink, J; Kuipers, T; van der Laan, B; Kremer, S

    2016-01-01

    The introduction of the dsm-5 has re-ignited discussion about the classification of mental disorders. The public may have misconceptions with regard to the nature of the information contained in a dsm-classification. To bring about a conceptual switch so that the professional user of a classification sees it as an aid to diagnosis rather than as a definition of a problem or illness. We devised a 'thought experiment' to serve as a support for dsm classifications. The 'thought experiment' led us to devise a medicine package containing a 'philosophical' information leaflet. This 'thought-experiment', the information leaflet and the medicine package were presented to both students and trainee doctors at the ucp in Groningen and to clinicians at the fpc dr. S. van Mesdag Clinic. Students and trainee doctors were able to make the desired conceptual switch as a result of 'the thought experiment' and with the help they received from the medicine packaging containing the 'philosophical' information leaflet.

  16. Developing leaflets to give dental health advice to Aboriginal families with young children.

    PubMed

    Blinkhorn, Fiona; Wallace, Janet; Smith, Leanne; Blinkhorn, Anthony S

    2014-08-01

    Dental caries (decay) is a serious problem for young Aboriginal children, causing pain and stress. Treatment often involves extraction of teeth under a general anaesthetic. However, dental caries can be prevented by reducing the frequency of sugar consumption and brushing teeth twice a day with fluoride toothpaste. Such straightforward advice could be given to families by Aboriginal Health Workers who are trusted by their communities and have an existing advisory role. This paper reports on the development of dental health advice leaflets for use in Aboriginal communities. An Aboriginal reference panel was recruited to comment on dental health advice leaflets prepared by an Aboriginal graphic designer. The panel was asked to consider the design, cultural appropriateness and practicality of the leaflets. Comments were collected through email and face-to-face discussions, which were collated and the leaflets altered accordingly. The advice from the panel resulted in greater use of pictures. For example large green ticks and red crosses highlighted healthy and unhealthy behaviours, respectively. The tooth brushing leaflet was amended to emphasise the safe storage of toothpaste in order to keep it out of reach of young children. The panel stated that all leaflets should incorporate the Aboriginal flag, and proposed that fridge magnets might be beneficial as all family members would benefit from seeing the messages every day. The consultation process refined dental advice leaflets to reflect the views of an Aboriginal Reference Panel, in terms of design, cultural competence and practicality. © 2014 FDI World Dental Federation.

  17. The development and testing of a brief ('gist-based') supplementary colorectal cancer screening information leaflet.

    PubMed

    Smith, Samuel G; Wolf, Michael S; Obichere, Austin; Raine, Rosalind; Wardle, Jane; von Wagner, Christian

    2013-12-01

    To design and user-test a 'gist-based' colorectal cancer screening information leaflet, which promotes comprehension of the screening offer. Twenty-eight individuals approaching screening age were recruited from organisations in deprived areas of England. Using a between-subjects design, we tested iterations of a newly-designed gist-based information leaflet. Participants read the leaflet and answered 8 'true' or 'false' comprehension statements. For the leaflet to be considered fit-for-purpose, all statements had to be answered correctly by at least 80% of participants in each round. Alterations were made if this threshold was not met and additional rounds of testing were undertaken. At round 1, answers to 2/8 statements did not meet the threshold. After changes, answers in round 2 did not reach the threshold for 1/8 statements. In round 3, all answers were adequate and the leaflet was deemed fit-for-purpose. Qualitative data offered solutions such as language and layout changes which led to improved comprehension of the leaflet. User-testing substantially improved the design and subsequent comprehensibility of a theory-driven gist-based colorectal cancer screening information leaflet. This leaflet will be evaluated as part of a large national randomised controlled trial designed to reduce socioeconomic inequalities in colorectal cancer screening participation. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  18. Initial Experience and Early Results of Mitral Valve Repair with Cardiocel Pericardial Patch.

    PubMed

    Tomšič, Anton; Bissessar, Daniella D; van Brakel, Thomas J; Marsan, Nina Ajmone; Klautz, Robert J M; Palmen, Meindert

    2018-06-07

    To assess the performance of a tissue engineering process-treated bovine pericardium patch (CardioCel) in the setting of reconstructive mitral valve surgery. Between 3/2014 and 4/2016, 30 patients (57.2±14.3 years, 27% female) underwent mitral valve leaflet repair with a CardioCel patch. Perioperative mortality was 7% (2 patients, non-graft-related). In 28 remaining patients, pre-discharge echocardiography demonstrated good repaired valve function. At a mean follow-up of 1.7±0.9 years, 3 additional deaths occurred (2 due to infective endocarditis, 1 non-cardiac related). On follow-up echocardiography [follow-up time 1.7±0.8 years, available for 26/28 (93%) hospital survivors], recurrent regurgitation was seen in 2 patients (both infective endocarditis) and 1 underwent reoperation (no infection at the level of patch repair was observed). In the remaining patients, the most recent echocardiogram demonstrated ≤mild regurgitation and stable gradients. The thickness and echodensity of the implanted patch on follow-up echocardiograms were comparable with postoperative echocardiograms. Initial results of the CardioCel patch in mitral valve repair surgery are satisfactory. The resistance to infection and late degeneration will need to be assessed in the future. Copyright © 2018. Published by Elsevier Inc.

  19. Dynamic and fluid-structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models

    NASA Astrophysics Data System (ADS)

    Hsu, Ming-Chen; Kamensky, David; Xu, Fei; Kiendl, Josef; Wang, Chenglong; Wu, Michael C. H.; Mineroff, Joshua; Reali, Alessandro; Bazilevs, Yuri; Sacks, Michael S.

    2015-06-01

    This paper builds on a recently developed immersogeometric fluid-structure interaction (FSI) methodology for bioprosthetic heart valve (BHV) modeling and simulation. It enhances the proposed framework in the areas of geometry design and constitutive modeling. With these enhancements, BHV FSI simulations may be performed with greater levels of automation, robustness and physical realism. In addition, the paper presents a comparison between FSI analysis and standalone structural dynamics simulation driven by prescribed transvalvular pressure, the latter being a more common modeling choice for this class of problems. The FSI computation achieved better physiological realism in predicting the valve leaflet deformation than its standalone structural dynamics counterpart.

  20. Dynamic and fluid–structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models

    PubMed Central

    Kamensky, David; Xu, Fei; Kiendl, Josef; Wang, Chenglong; Wu, Michael C. H.; Mineroff, Joshua; Reali, Alessandro; Bazilevs, Yuri; Sacks, Michael S.

    2015-01-01

    This paper builds on a recently developed immersogeometric fluid–structure interaction (FSI) methodology for bioprosthetic heart valve (BHV) modeling and simulation. It enhances the proposed framework in the areas of geometry design and constitutive modeling. With these enhancements, BHV FSI simulations may be performed with greater levels of automation, robustness and physical realism. In addition, the paper presents a comparison between FSI analysis and standalone structural dynamics simulation driven by prescribed transvalvular pressure, the latter being a more common modeling choice for this class of problems. The FSI computation achieved better physiological realism in predicting the valve leaflet deformation than its standalone structural dynamics counterpart. PMID:26392645

  1. Weaving for heart valve tissue engineering.

    PubMed

    Liberski, Albert; Ayad, Nadia; Wojciechowska, Dorota; Kot, Radoslaw; Vo, Duy M P; Aibibu, Dilibaier; Hoffmann, Gerald; Cherif, Chokri; Grobelny-Mayer, Katharina; Snycerski, Marek; Goldmann, Helmut

    2017-11-01

    Weaving is a resourceful technology which offers a large selection of solutions that are readily adaptable for tissue engineering (TE) of artificial heart valves (HV). The different ways that the yarns are interlaced in this technique could be used to produce complex architectures, such as the three-layer architecture of the leaflets. Once the assembly is complete, growth of cells in the scaffold would occur in the orientation of the yarn, enabling the deposition of extra cellular matrixes proteins in an oriented manner. Weaving technology is a rapidly evolving field that, first, needs to be understood, and then explored by tissue engineers, so that it could be used to create efficient scaffolds. Similarly, the textile engineers need to gain a basic understanding of key structural and mechanical aspects of the heart valve. The aim of this review is to provide the platform for joining these two fields and to enable cooperative research efforts. Moreover, examples of woven medical products and patents as well as related publication are discussed in this review, nevertheless due to the large, and continuously growing volume of data, only the aspects strictly associated with HVTE lay in the scope of this paper. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Charged anaesthetics alter LM-fibroblast plasma-membrane enzymes by selective fluidization of inner or outer membrane leaflets.

    PubMed Central

    Sweet, W D; Schroeder, F

    1986-01-01

    The functional consequences of the differences in lipid composition and structure between the two leaflets of the plasma membrane were investigated. Fluorescence of 1,6-diphenylhexa-1,3,5-triene(DPH), quenching, and differential polarized phase fluorimetry demonstrated selective fluidization by local anaesthetics of individual leaflets in isolated LM-cell plasma membranes. As measured by decreased limiting anisotropy of DPH fluorescence, cationic (prilocaine) and anionic (phenobarbital and pentobarbital) amphipaths preferentially fluidized the cytofacial and exofacial leaflets respectively. Unlike prilocaine, procaine, also a cation, fluidized both leaflets of these membranes equally. Pentobarbital stimulated 5'-nucleotidase between 0.1 and 5 mM and inhibited at higher concentrations, whereas phenobarbital only inhibited, at higher concentrations. Cationic drugs were ineffective. Two maxima of (Na+ + K+)-ATPase activation were obtained with both anionic drugs. Only one activation maximum was obtained with both cationic drugs. The maximum in activity below 1 mM for all four drugs clustered about a single limiting anisotropy value in the cytofacial leaflet, whereas there was no correlation between activity and limiting anisotropy in the exofacial leaflets. Therefore, although phenobarbital and pentobarbital below 1 mM fluidized the exofacial leaflet more than the cytofacial leaflet, the smaller fluidization in the cytofacial leaflet was functionally significant for (Na+ + K+)-ATPase. Mg2+-ATPase was stimulated at 1 mM-phenobarbital, unaffected by pentobarbital and slightly stimulated by both cationic drugs at concentrations fluidizing both leaflets. Thus the activity of (Na+ + K+)-ATPase was highly sensitive to selective fluidization of the leaflet containing its active site, whereas the other enzymes examined were little affected by fluidization of either leaflet. PMID:3028369

  3. Colposcopy information leaflets: what women want to know and when they want to receive this information.

    PubMed

    Byrom, J; Dunn, P D J; Hughes, G M; Lockett, J; Johnson, A; Neale, J; Redman, C W E

    2003-01-01

    To evaluate whether the information leaflets produced by UK colposcopy clinics provide women with the information they desire and to determine when they would like to receive this information. Questionnaire study and structured evaluation. The colposcopy clinic of a UK cancer centre. Forty-two women attending a pre-colposcopy counselling session and 100 consecutive women attending the colposcopy clinic. Thirty-eight standards derived from the concerns/questions asked by women attending a pre-colposcopy counselling session were used to assess locally produced colposcopy clinic leaflets from UK colposcopy clinics, the leaflets produced by the Royal College of Obstetricians and Gynaecologists and the National Health Service Cervical Screening Programme (NHSCSP), and two "leaflets" obtained from internet sites. The Gunning fog test was used to assess the leaflets' readability. A questionnaire survey of 100 women attending the colposcopy clinic was used to determine when women wanted to receive information about colposcopy. Percentage of questions answered by a given leaflet and Gunning fog scores for readability. The information leaflets of 128 colposcopy clinics were received and assessed. Thirty-two clinics only sent women the NHSCSP leaflet. No leaflet answered all 38 questions. Less than half (36/100) of the leaflets answered more than 50% of the questions. In addition to the lack of advice given, different leaflets frequently gave conflicting advice. The average Gunning fog score was 9.7 (range 5.5-15.5). The majority of women (70%) wanted to receive information about colposcopy at or prior to the time of receiving their abnormal smear test result, although only 42% of women actually received information at this time. Many UK colposcopy clinics do not appear to be providing women with the information they require to understand their condition and the procedure that they are about to undergo. Furthermore, this information is often not provided at the appropriate

  4. Live/real time three-dimensional transthoracic echocardiographic assessment of tricuspid valve pathology: incremental value over the two-dimensional technique.

    PubMed

    Pothineni, Koteswara R; Duncan, Kurt; Yelamanchili, Pridhvi; Nanda, Navin C; Patel, Vinod; Fan, PoHoey; Burri, Manjula V; Singh, Anurag; Panwar, Sadik R

    2007-05-01

    Twenty-nine patients with different tricuspid valve (TV) pathologies were studied by both two-dimensional transthoracic (2DTTE) and live/real time three-dimensional transthoracic echocardiography (3DTTE). A major contribution of 3DTTE over 2DTTE was the en face visualization of all three leaflets of the TV in all patients. This allowed accurate assessment of TV orifice area in patients with TV stenosis and carcinoid disease. Loss of TV leaflet tissue, defects in TV leaflets and size of TV systolic non-coaptation could also be delineated and resulted in identifying the mechanism of tricuspid regurgitation (TR) in patients with Ebstein's anomaly and rheumatic heart disease. Prolapse of TV leaflets could also be well visualized and enabled us to develop a schema for systematic assessment of individual segment prolapse which could help in surgical planning. The exact sites of chordae rupture in patients with flail TV as well as right ventricular papillary muscle rupture could be well seen by 3DTTE. 3DTTE also permitted sectioning of various TV masses for more specific diagnosis of their nature. In addition, color Doppler 3DTTE provided an estimate of quantitative evaluation of TR severity, since the exact shape and size of the vena contracta could be accurately assessed. In conclusion, our preliminary experience with 3DTTE has demonstrated substantial incremental value over 2DTTE in the assessment of various TV pathologies.

  5. Effect of a leaflet given to parents on knowledge of tooth avulsion.

    PubMed

    Ghaderi, F; Adl, A; Ranjbar, Z

    2013-03-01

    Parents can play an important role in improving the prognosis of avulsed permanent teeth if they are properly informed about the necessary dental first-aid steps at the time of an accident. The purpose of this study was to assess the knowledge of Shirazi parents in traumatic a simple leaflet on improving their knowledge about this topic. One hundred and fifty parents of children receiving dental care at the Shiraz Dental School participated in this study. Half of the participants received an informative leaflet with the possibility of asking questions about it to an operator, while the other half did not receive any leaflets and served as a control group. Using a questionnaire and a scoring system, the level of knowledge of parents was measured in the following categories: general knowledge of tooth avulsion, knowledge of replantation and primary/permanent teeth, knowledge of how to clean an avulsed tooth, knowledge of extra- oral time, and knowledge of storage, methods and transporting media. The results showed that knowledge level was low among Shirazi parents. Improvements were observed in all the categories of knowledge as a result of reading the leaflet and answering the questions. A simple leaflet is a suitable tool to impart knowledge to parents and improve awareness about tooth avulsion.

  6. The clover technique for the treatment of complex tricuspid valve insufficiency: midterm clinical and echocardiographic results in 66 patients.

    PubMed

    Lapenna, Elisabetta; De Bonis, Michele; Verzini, Alessandro; La Canna, Giovanni; Ferrara, David; Calabrese, Maria Chiara; Taramasso, Maurizio; Alfieri, Ottavio

    2010-06-01

    This study assesses the results of the 'clover technique' (suturing together the middle point of the free edges of the tricuspid leaflets) for the treatment of tricuspid regurgitation (TR) due to severe prolapse or tethering. From 2001, 66 patients with severe TR due to prolapsing or tethered leaflets underwent 'clover repair'. Annuloplasty was associated in 64 patients (97%). The aetiology of TR was degenerative in 52 cases (79%), post-traumatic in eight (12%) and secondary to dilated cardiomyopathy (DCM) in six (9%). The main mechanism of TR was prolapse/flail of one leaflet in 15 patients (23%), of two leaflets in 31 (47%) and of all three leaflets in 14 (21%). The remaining six patients (9%) presented with severe leaflets' tethering. Four deaths (6%) occurred during hospitalisation and one patient died 3.6 years after surgery. Survival was 91 + or - 4.1% at 5 years. Follow-up of the 62 hospital survivors was 100% complete (mean length 3.5 + or - 1.6 years, range 13 months-7.1 years). At the last echocardiogram, no or mild TR was detected in 55 (88.7%) patients, moderate (2+/4+) in six (9.6%) and severe (4+/4+) in one patient (1.6%). Mean tricuspid valve area and gradient were 4.3 + or - 0.6 cm(2) and 2.8 + or -1.4 mmHg. In six patients, stress echocardiography was performed and no signs of tricuspid stenosis were detected. At the multivariable analysis, the degree of TR at hospital discharge was identified as the only predictor of TR > or = 2+ at follow-up. Midterm clinical and echocardiographic results confirm the role of the 'clover technique' in the surgical treatment of TR due to lesions, which are unlikely to be effectively treatable by annuloplasty alone. Copyright 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  7. Patient-specific indirectly 3D printed mitral valves for pre-operative surgical modelling

    NASA Astrophysics Data System (ADS)

    Ginty, Olivia; Moore, John; Xia, Wenyao; Bainbridge, Dan; Peters, Terry

    2017-03-01

    Significant mitral valve regurgitation affects over 2% of the population. Over the past few decades, mitral valve (MV) repair has become the preferred treatment option, producing better patient outcomes than MV replacement, but requiring more expertise. Recently, 3D printing has been used to assist surgeons in planning optimal treatments for complex surgery, thus increasing the experience of surgeons and the success of MV repairs. However, while commercially available 3D printers are capable of printing soft, tissue-like material, they cannot replicate the demanding combination of echogenicity, physical flexibility and strength of the mitral valve. In this work, we propose the use of trans-esophageal echocardiography (TEE) 3D image data and inexpensive 3D printing technology to create patient specific mitral valve models. Patient specific 3D TEE images were segmented and used to generate a profile of the mitral valve leaflets. This profile was 3D printed and integrated into a mold to generate a silicone valve model that was placed in a dynamic heart phantom. Our primary goal is to use silicone models to assess different repair options prior to surgery, in the hope of optimizing patient outcomes. As a corollary, a database of patient specific models can then be used as a trainer for new surgeons, using a beating heart simulator to assess success. The current work reports preliminary results, quantifying basic morphological properties. The models were assessed using 3D TEE images, as well as 2D and 3D Doppler images for comparison to the original patient TEE data.

  8. Mitral leaflet geometry perturbations with papillary muscle displacement and annular dilatation: an in-vitro study of ischemic mitral regurgitation.

    PubMed

    He, Shengqiu; Jimenez, Jorge; He, Zhaoming; Yoganathan, Ajit P

    2003-05-01

    Perturbations of leaflet geometry are the final end point through which left ventricular (LV) ischemia causes incomplete mitral leaflet closure and resultant mitral regurgitation (MR). Geometric inconsistencies observed with valvular or subvalvular structural alterations raise several questions. A new in-vitro LV flexible bag model was developed in order to visualize and analyze leaflet geometric changes under simulated pathological ischemic MR conditions. Papillary muscle (PM) displacement and annular dilatation decreased leaflet coaptation length, leading to significant MR. Symmetrical PM displacement shifted the coaptation line towards the leaflet edges and created central gaps along this line. Asymmetric PM displacement generated diametrically uneven coaptation with a tent-shaped leaflet at the tethered PM side, while the leaflet bulged at the opposite side towards the left atrium. Leaflet geometry during systole is affected by subvalvular structures. Asymmetric PM displacement, which may occur in regional or acute myocardial infarction, induces irregular deformation of the leaflet's coaptation line and, as a result, MR at the tethered side. Direct visualization of leaflet perturbation under these simulated pathological conditions may promote understanding of mechanisms present in ischemic MR.

  9. Readability of medicinal package leaflets: a systematic review

    PubMed Central

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords “Readability and Package Leaflet” and “Readability and Package Insert” in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the

  10. Educating adolescents about healthy sleep: experimental study of effectiveness of educational leaflet.

    PubMed

    Bakotić, Marija; Radosević-Vidacek, Biserka; Kosćec, Adrijana

    2009-04-01

    To evaluate how exposure to educational leaflet about healthy sleep affects knowledge about sleep in adolescents. The study included students aged 15-18 years from 12 high schools (1209 participants; 85% of eligible study population). Multistage sampling was used and the selected schools were randomly assigned into two intervention groups and two control groups, according to the Solomon experimental design. Intervention groups received educational leaflets and control groups did not. In one of the intervention groups and one of the control groups, pre-testing of knowledge about sleep was performed. Students answered the Sleep Knowledge Test, which was constructed in accordance with the information on the leaflet. Data were analyzed by four-way ANOVA and additional analyses of simple main effects were performed. Positive effect of educational leaflet was found in students aged 15 (F = 28.46; P < 0.001), 16 (F = 5.74; P = 0.017), and 17 (F = 17.17; P < 0.001), but there was no effect in students aged 18 (P = 0.467). In male students, positive effect of the leaflet was found only in the group that had not been pre-tested (F = 6.29; P = 0.012), while in female students, it was found in both pre-tested (F = 26.24; P < 0.001) and not pre-tested group (F = 17.36; P < 0.001), with greater effect in pre-tested group (F = 5.70; P = 0.017). Female students generally showed better knowledge about sleep than male students (F = 95.95; P < 0.001). Educational leaflets can be an effective first step in educating younger high school students about healthy sleep, with the method being more effective in female adolescents.

  11. Simplified pulse reactor for real-time long-term in vitro testing of biological heart valves.

    PubMed

    Schleicher, Martina; Sammler, Günther; Schmauder, Michael; Fritze, Olaf; Huber, Agnes J; Schenke-Layland, Katja; Ditze, Günter; Stock, Ulrich A

    2010-05-01

    Long-term function of biological heart valve prostheses (BHV) is limited by structural deterioration leading to failure with associated arterial hypertension. The objective of this work was development of an easy to handle real-time pulse reactor for evaluation of biological and tissue engineered heart valves under different pressures and long-term conditions. The pulse reactor was made of medical grade materials for placement in a 37 degrees C incubator. Heart valves were mounted in a housing disc moving horizontally in culture medium within a cylindrical culture reservoir. The microprocessor-controlled system was driven by pressure resulting in a cardiac-like cycle enabling competent opening and closing of the leaflets with adjustable pulse rates and pressures between 0.25 to 2 Hz and up to 180/80 mmHg, respectively. A custom-made imaging system with an integrated high-speed camera and image processing software allow calculation of effective orifice areas during cardiac cycle. This simple pulse reactor design allows reproducible generation of patient-like pressure conditions and data collection during long-term experiments.

  12. Repair of Parachute and Hammock Valve in Infants and Children: Early and Late Outcomes.

    PubMed

    Delmo Walter, Eva Maria; Javier, Mariano; Hetzer, Roland

    2016-01-01

    Parachute and hammock valves in children remain one of the most challenging congenital malformations to correct. We report our institutional experience with valve-preserving repair techniques and the early and late surgical outcomes in parachute and hammock valves in infants and children. From January 1990-June 2014, 20 infants and children with parachute (n = 12, median age = 2.5 years, range: 2 months-13 years) and hammock (n = 8, median age = 7 months, range: 1 month-14.9 years) valves underwent mitral valve (MV) repair. Children with parachute valves have predominant stenosis, whereas those with hammock valves often have predominant insufficiency. Intraoperative findings included fused and shortened chordae with single papillary muscles in children with parachute valves. MV repair was performed using annuloplasty, commissurotomy, leaflet incision toward the body of the papillary muscles, and split toward its base. Children with hammock valves have dysplastic and shortened chordae, absence of papillary muscles with fused and thickened commissures. MV repair consisted of carving off a suitably thick part of the left ventricular wall carrying the rudimentary chordae. The degree and extent of incision and commissurotomy is determined by the minimal age-related acceptable MV diameter to avoid mitral stenosis. During a median duration of follow-up of 9.6 years (range: 6.4-21.4 years), cumulative survival rate and freedom from reoperation in parachute valves were 43.7 ± 1.6% and 53.0 ± 1.8%, respectively. In hammock valves, during a median duration of follow-up of 6.7 years (range: 2.7-19.4 years), cumulative survival rate and freedom from reoperation was 72.9 ± 1.6% and 30.0 ± 1.7%, respectively. Age less than 1 year proved to be a high-risk factor for reoperation and mortality (P < 0.005). In conclusion, children with parachute and hammock valves, repeat MV repair may be necessary during the course of follow-up. Infants have a greater risk for reoperation and

  13. Light-dependent changes in the leaflet movement rhythm of the plant Desmodium gyrans.

    PubMed

    Sharma, Vijay Kumar; Bardal, Tom Kristian; Johnsson, Anders

    2003-01-01

    The movements of the lateral leaflets of the Indian telegraph plant Desmodium gyrans (L. F.) DC, have earlier been studied in detail with regards to the effects of chemicals, DC currents, and static magnetic fields. In the present paper we have discussed the oscillation of the lateral leaflets under the influence of white light of various light levels (0-75 micromol x m(-2) x s(-1)), produced by an array of LEDs (light emitting diodes). LEDs were used in contrast to fluorescense tubes as in earlier studies in order to minimize changes of wavelength when light intensity was decreased or increased. Furthermore, care was taken to ensure that the temperature in the experimental chamber was constant. When the oscillations were first monitored in bright light, the oscillations were found to be very rapid and with decreasing light intensity the oscillations slowed down. For light levels lower than about 20 micromol x m(-2) x s(-1) the period of the oscillation of the lateral leaflets was almost constant (or even decreased slightly towards complete darkness). We also show that the oscillations could completely stop under prolonged darkness (for longer than about 6 h) and that such halted oscillations could be restarted in most of the leaflets when he light was turned back on. Such stopping of the oscillation of the lateral leaflets in prolonged darkness suggests that these short period oscillations of the lateral leaflets could have a daily component and in natural environment these oscillations could serve the purpose of optimising the amount of light falling on the leaflets or/and facilitating transpiration of water through stomata. Such a finding could have an implication for the answer to the long standing question of adaptive significance of short period oscillation of the Indian telegraph plant Desmodium gyrans (L. F.) DC.

  14. Smad2-dependent glycosaminoglycan elongation in aortic valve interstitial cells enhances binding of LDL to proteoglycans.

    PubMed

    Osman, Narin; Grande-Allen, K Jane; Ballinger, Mandy L; Getachew, Robel; Marasco, Silvana; O'Brien, Kevin D; Little, Peter J

    2013-01-01

    Calcific aortic valve disease is a progressive condition that shares some common pathogenic features with atherosclerosis. Transforming growth factor-β1 is a recognized mediator of atherosclerosis and is expressed in aortic valve lesions. Transforming growth factorβ1 stimulates glycosaminoglycan elongation of proteoglycans that is associated with increased lipid binding. We investigated the presence of transforming growth factor-β1 and downstream signaling intermediates in diseased human aortic valves and the effects of activated transforming growth factor-β1 receptor signaling on aortic valve interstitial cell proteoglycan synthesis and lipid binding as a possible mechanism for the initiation of the early lesion of calcific aortic valve disease. Diseased human aortic valve leaflets demonstrated strong immunohistochemical staining for transforming growth factor-β1 and phosphorylated Smad2/3. In primary porcine aortic valve interstitial cells, Western blots showed that transforming growth factor-β1 stimulated phosphorylation in both the carboxy and linker regions of Smad2/3, which was inhibited by the transforming growth factor-β1 receptor inhibitor SB431542. Gel electrophoresis and size exclusion chromatography demonstrated that SB431542 decreased transforming growth factor-β1-mediated [(35)S]-sulfate incorporation into proteoglycans in a dose-dependent manner. Further, in proteoglycans derived from transforming growth factor-β1-treated valve interstitial cells, gel mobility shift assays demonstrated that inhibition of transforming growth factor-β1 receptor signaling resulted in decreased lipid binding. Classic transforming growth factor-β1 signaling is present in human aortic valves in vivo and contributes to the modification of proteoglycans expressed by valve interstitial cells in vitro. These findings suggest that transforming growth factor-β1 may promote increased low-density lipoprotein binding in the early phases of calcific aortic valve disease

  15. The Effects of Combined Cyclic Stretch and Pressure on the Aortic Valve Interstitial Cell Phenotype

    PubMed Central

    Thayer, Patrick; Balachandran, Kartik; Rathan, Swetha; Yap, Choon Hwai; Arjunon, Sivakkumar; Jo, Hanjoong; Yoganathan, Ajit P.

    2017-01-01

    Aortic valve interstitial cells (VIC) can exhibit phenotypic characteristics of fibroblasts, myofibroblasts, and smooth muscle cells. Others have proposed that valve cells become activated and exhibit myofibroblast or fibroblast characteristics during disease initiation and progression; however, the cues that modulate this phenotypic change remain unclear. We hypothesize that the mechanical forces experienced by the valve play a role in regulating the native phenotype of the valve and that altered mechanical forces result in an activated phenotype. Using a novel ex vivo cyclic stretch and pressure bioreactor, we subjected porcine aortic valve (AV) leaflets to combinations of normal and pathological stretch and pressure magnitudes. The myofibroblast markers α-SMA and Vimentin, along with the smooth muscle markers Calponin and Caldesmon, were analyzed using immunohistochemistry and immunoblotting. Tissue structure was analyzed using Movat’s pentachrome staining. We report that pathological stretch and pressure inhibited the contractile and possibly myofibroblast phenotypes as indicated by downregulation of the proteins α-SMA, Vimentin, and Calponin. In particular, Calponin downregulation implies depolymerization of actin filaments and possible conversion to a more synthetic (non-contractile) phenotype. This agreed well with the increase in spongiosa and fibrosa thickness observed under elevated pressure and stretch that are typically indicative of increased matrix synthesis. Our study therefore demonstrates how cyclic stretch and pressure may possibly act together to modulate the AVIC phenotype. PMID:21347552

  16. All you need to know about the tricuspid valve: Tricuspid valve imaging and tricuspid regurgitation analysis.

    PubMed

    Huttin, Olivier; Voilliot, Damien; Mandry, Damien; Venner, Clément; Juillière, Yves; Selton-Suty, Christine

    2016-01-01

    The acknowledgment of tricuspid regurgitation (TR) as a stand-alone and progressive entity, worsening the prognosis of patients whatever its aetiology, has led to renewed interest in the tricuspid-right ventricular complex. The tricuspid valve (TV) is a complex, dynamic and changing structure. As the TV is not easy to analyse, three-dimensional imaging, cardiac magnetic resonance imaging and computed tomography scans may add to two-dimensional transthoracic and transoesophageal echocardiographic data in the analysis of TR. Not only the severity of TR, but also its mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. TR is functional and is a satellite of left-sided heart disease and/or elevated pulmonary artery pressure most of the time; a particular form is characterized by TR worsening after left-sided valve surgery, which has been shown to impair patient prognosis. A better description of TV anatomy and function by multimodality imaging should help with the appropriate selection of patients who will benefit from either surgical TV repair/replacement or a percutaneous procedure for TR, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Photosynthetic carbon metabolism in leaflets, stipules and tendrils of Pisum sativum L

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cote, R.; Grodzinski, B.

    1990-05-01

    Gas exchange and photosynthetic carbon metabolism have been investigated for each of the dominant parts of the pea leaf (P. sativum) in a normal and a semi-leafless phenotype (cv. Improved Laxton's Progress, and cv. Curly, respectively). On a fresh weight basis, net photosynthesis of leaflets and stipules have similar rates, while in tendrils the rte is 40% lower. However, on a surface area basis, tendrils are only 5-10% less efficient photosynthetically when the area is corrected by a factor {pi}/2. Transpiration rates are similar for leaflets and stipules, but double for tendrils even though stomatal frequency on tendrils is reducedmore » by 50%. Dark respiration is higher in tendrils than leaflets and stipules. Gas exchange is comparable in both cultivars. The early {sup 14}C-labelled products of stipules, leaflets and tendrils are similar in both phenotypes, however the tendrils clearly partition about 2-3 times more of the newly fixed {sup 14}CO{sub 2} into the amino acid fraction. These data will be discussed in relation to the anatomy and function of pea tendrils.« less

  18. Regression of aortic valve stenosis by ApoA-I mimetic peptide infusions in rabbits

    PubMed Central

    Busseuil, D; Shi, Y; Mecteau, M; Brand, G; Kernaleguen, A-E; Thorin, E; Latour, J-G; Rhéaume, E; Tardif, J-C

    2008-01-01

    Background and purpose: Aortic valve stenosis (AVS) is the most common valvular heart disease, and standard curative therapy remains open heart surgical valve replacement. The aim of our experimental study was to determine if apolipoprotein A-I (ApoA-I) mimetic peptide infusions could induce regression of AVS. Experimental approach: Fifteen New Zealand White male rabbits received a cholesterol-enriched diet and vitamin D2 until significant AVS was detected by echocardiography. The enriched diet was then stopped to mimic cholesterol-lowering therapy and animals were allocated randomly to receive saline (control group, n=8) or an ApoA-I mimetic peptide (treated group, n=7), three times per week for 2 weeks. Serial echocardiograms and post mortem valve histology were performed. Key results: Aortic valve area increased significantly by 25% in the treated group after 14 days of treatment (P=0.012). Likewise, aortic valve thickness decreased by 21% in the treated group, whereas it was unchanged in controls (P=0.0006). Histological analysis revealed that the extent of lesions at the base of valve leaflets and sinuses of Valsalva was smaller in the treated group compared with controls (P=0.032). The treatment also reduced calcification, as revealed by the loss of the positive relationship observed in the control group (r=0.87, P=0.004) between calcification area and aortic valve thickness. Conclusions and implications: Infusions of ApoA-I mimetic peptide lead to regression of experimental AVS. These positive results justify the further testing of high-density lipoprotein (HDL)-based therapies in patients with valvular aortic stenosis. Regression of aortic stenosis, if achieved safely, could transform the clinical treatment of this disease. PMID:18414386

  19. A New Cone-Shaped Aortic Valve Prosthesis for Orthotopic Position: An Experimental Study in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan, E-mail: jan.sochman@medicon.c; Peregrin, Jan H.; Pulda, Zdenek

    The aim of this experimental study was to evaluate a newly designed cone-shaped aortic valve prosthesis (CAVP) for one-step transcatheter placement in an orthotopic position. The study was conducted in 15 swine using either the transcarotid (11 animals) or the transfemoral (4 animals) artery approach. A 12- or 13-Fr sheath was inserted via arterial cutdown. The CAVP was deployed under fluoroscopic control and its struts, by design, induced significant native valve insufficiency. CAVP function was evaluated by aortography and aortic pressure curve tracing. In 11 of 15 swine the CAVP was properly deployed and functioned well throughout the scheduled periodmore » of 2-3 h. In three swine the CAVPs were placed lower than intended, however, they were functional even in the left ventricular outflow tract position. One swine expired due to inadvertent low CAVP placement that caused both aortic regurgitation and immobilization of the anterior mitral valve leaflet by the valve struts. We conclude that this design of CAVP is relatively easy to deploy, works well throughout a short time period (2-3 h), and, moreover, seems to be reliable even in a lower-than-orthotopic position (e.g., infra-annulary space). Longer-term studies are needed for its further evaluation.« less

  20. Shelf-life of bioprosthetic heart valves: a structural and mechanical study.

    PubMed

    Julien, M; Létouneau, D R; Marois, Y; Cardou, A; King, M W; Guidoin, R; Chachra, D; Lee, J M

    1997-04-01

    This study was undertaken to evaluate the influence of storage conditions on the shelf-life of porcine bioprosthetic valves. Fifty-five unimplanted porcine bioprostheses have been evaluated. The valves were stored in 0.5% buffered glutaraldehyde solution for different periods of time (7, 23 and 32 months). Twenty-eight valves were refrigerated while the remaining valves were stored at room temperature. The pH of the glutaraldehyde solution at room temperature decreased with time of storage, while that kept in the refrigerator remained stable over the course of the study. Macroscopic observations showed that the valve tissues kept at room temperature, especially for the periods of 23 and 32 months, became darker and more yellow in colour, whereas the refrigerated specimens exhibited no such changes in appearance. Scanning electron microscopy analysis revealed no noticeable differences on the surfaces of the leaflets stored under different conditions. Mechanical tests, including stress-strain response, stress relaxation and fracture behaviour, were carried out. Analysis of variance showed that the storage temperature, but not the length of storage, had a significant effect on some mechanical properties. The stress relaxation at 1000 s (P = 0.05), the ultimate tensile strength (P = 0.01) and the strain at fracture (P = 0.04) were all higher after storage at room temperature compared to the results after refrigeration. No statistically significant changes in the denaturation temperature of the collagen were observed between the different storage conditions. In conclusion, the storage temperature appears to have some influence on the bioprosthetic tissue. The bioprostheses stored under ambient conditions experience changes which may influence their longterm in vivo performance.

  1. Transmembrane protein diffusion in gel-supported dual-leaflet membranes.

    PubMed

    Wang, Chih-Ying; Hill, Reghan J

    2014-11-18

    Tools to measure transmembrane-protein diffusion in lipid bilayer membranes have advanced in recent decades, providing a need for predictive theoretical models that account for interleaflet leaflet friction on tracer mobility. Here we address the fully three-dimensional flows driven by a (nonprotruding) transmembrane protein embedded in a dual-leaflet membrane that is supported above and below by soft porous supports (e.g., hydrogel or extracellular matrix), each of which has a prescribed permeability and solvent viscosity. For asymmetric configurations, i.e., supports with contrasting permeability, as realized for cells in contact with hydrogel scaffolds or culture media, the diffusion coefficient can reflect interleaflet friction. Reasonable approximations, for sufficiently large tracers on low-permeability supports, are furnished by a recent phenomenological theory from the literature. Interpreting literature data, albeit for hard-supported membranes, provides a theoretical basis for the phenomenological Stokes drag law as well as strengthening assertions that nonhydrodynamic interactions are important in supported bilayer systems, possibly leading to overestimates of the membrane/leaflet viscosity. Our theory provides a theoretical foundation for future experimental studies of tracer diffusion in gel-supported membranes.

  2. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall be...

  3. Immersed smoothed finite element method for fluid-structure interaction simulation of aortic valves

    NASA Astrophysics Data System (ADS)

    Yao, Jianyao; Liu, G. R.; Narmoneva, Daria A.; Hinton, Robert B.; Zhang, Zhi-Qian

    2012-12-01

    This paper presents a novel numerical method for simulating the fluid-structure interaction (FSI) problems when blood flows over aortic valves. The method uses the immersed boundary/element method and the smoothed finite element method and hence it is termed as IS-FEM. The IS-FEM is a partitioned approach and does not need a body-fitted mesh for FSI simulations. It consists of three main modules: the fluid solver, the solid solver and the FSI force solver. In this work, the blood is modeled as incompressible viscous flow and solved using the characteristic-based-split scheme with FEM for spacial discretization. The leaflets of the aortic valve are modeled as Mooney-Rivlin hyperelastic materials and solved using smoothed finite element method (or S-FEM). The FSI force is calculated on the Lagrangian fictitious fluid mesh that is identical to the moving solid mesh. The octree search and neighbor-to-neighbor schemes are used to detect efficiently the FSI pairs of fluid and solid cells. As an example, a 3D idealized model of aortic valve is modeled, and the opening process of the valve is simulated using the proposed IS-FEM. Numerical results indicate that the IS-FEM can serve as an efficient tool in the study of aortic valve dynamics to reveal the details of stresses in the aortic valves, the flow velocities in the blood, and the shear forces on the interfaces. This tool can also be applied to animal models studying disease processes and may ultimately translate to a new adaptive methods working with magnetic resonance images, leading to improvements on diagnostic and prognostic paradigms, as well as surgical planning, in the care of patients.

  4. Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation.

    PubMed

    Pham, Thuy; Kong, Fanwei; Martin, Caitlin; Wang, Qian; Primiano, Charles; McKay, Raymond; Elefteriades, John; Sun, Wei

    2017-03-01

    Functional mitral regurgitation (FMR) is a significant complication of left ventricular dysfunction and strongly associated with a poor prognosis. In this study, we developed a patient-specific finite element (FE) model of the mitral apparatus in a FMR patient which included: both leaflets with thickness, annulus, chordae tendineae, and chordae insertions on the leaflets and origins on the papillary muscles. The FE model incorporated human age- and gender-matched anisotropic hyperelastic material properties, and MV closure at systole was simulated. The model was validated by comparing the FE results from valve closure simulation with the in vivo geometry of the MV at systole. It was found that the FE model could not replicate the in vivo MV geometry without the application of tethering pre-tension force in the chordae at diastole. Upon applying the pre-tension force and performing model optimization by adjusting the chordal length, position, and leaflet length, a good agreement between the FE model and the in vivo model was established. Not only were the chordal forces high at both diastole and systole, but the tethering force on the anterior papillary muscle was higher than that of the posterior papillary muscle, which resulted in an asymmetrical gap with a larger orifice area at the anterolateral commissure resulting in MR. The analyses further show that high peak stress and strain were found at the chordal insertions where large chordal tethering forces were found. This study shows that the pre-tension tethering force plays an important role in accurately simulating the MV dynamics in this FMR patient, particularly in quantifying the degree of leaflet coaptation and stress distribution. Due to the complexity of the disease, the patient-specific computational modeling procedure of FMR patients presented should be further evaluated using a large patient cohort. However, this study provides useful insights into the MV biomechanics of a FMR patient, and could serve

  5. Package leaflets of the most consumed medicines in Portugal: safety and regulatory compliance issues. A descriptive study.

    PubMed

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    Package leaflets are necessary for safe use of medicines. The aims of the present study were: 1) to assess the compliance between the content of the package leaflets and the specifications of the pharmaceutical regulations; and 2) to identify potential safety issues for patients. Qualitative descriptive study, involving all the package leaflets of branded medicines from the three most consumed therapeutic groups in Portugal, analyzed in the Department of Pharmacoepidemiology, School of Pharmacy, University of Lisbon. A checklist validated through an expert consensus process was used to gather the data. The content of each package leaflet in the sample was classified as compliant or non-compliant with compulsory regulatory issues (i.e. stated dosage and descriptions of adverse reactions) and optional regulatory issues (i.e. adverse reaction frequency, symptoms and procedures in cases of overdose). A total of 651 package leaflets were identified. Overall, the package leaflets were found to be compliant with the compulsory regulatory issues. However, the optional regulatory issues were only addressed in around half of the sample of package leaflets, which made it possible to identify some situations of potentially compromised drug safety. Ideally, the methodologies for package leaflet approval should be reviewed and optimized as a way of ensuring the inclusion of the minimum essential information for safe use of medicines.

  6. Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices.

    PubMed

    Bezuidenhout, Deon; Williams, David F; Zilla, Peter

    2015-01-01

    Efficient function and long-term durability without the need for anticoagulation, coupled with the ability to be accommodated in many different types of patient, are the principal requirements of replacement heart valves. Although the clinical use of valves appeared to have remained steady for several decades, the evolving demands for the elderly and frail patients typically encountered in the developed world, and the needs of much younger and poorer rheumatic heart disease patients in the developing world have now necessitated new paradigms for heart valve technologies and associated materials. This includes further consideration of durable elastomeric materials. The use of polymers to produce flexible leaflet valves that have the benefits of current commercial bioprosthetic and mechanical valves without any of their deficiencies has been held desirable since the mid 1950s. Much attention has been focused on thermoplastic polyurethanes in view of their generally good physico-chemical properties and versatility in processing, coupled with the improving biocompatibility and stability of recent formulations. Accelerated in vitro durability of between 600 and 1000 million cycles has been achieved using polycarbonate urethanes, and good resistance to degradation, calcification and thrombosis in vivo has been shown with some polysiloxane-based polyurethanes. Nevertheless, polymeric valves have remained relegated to use in temporary ventricular assist devices for bridging heart failure patients to transplantation. Some recent studies suggest that there is a greater degree of instability in thermoplastic materials than hitherto believed so that significant challenges remain in the search for the combination of durability and biocompatibility that would allow polymeric valves to become a clinical reality for surgical implantation. Perhaps more importantly, they could become candidates for use in situations where minimally invasive transcatheter procedures are used to

  7. [Experimental studies of original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica)].

    PubMed

    Murakami, T

    1989-05-01

    Extracardiac conduits, such as Dacron or homo-graft, have been utilized for the operative management of many patients with congenital right ventricular outflow obstruction. However, they have been recognized to become obstructed or calcified with time. As a new material for extracardiac conduit, an original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica) was investigated. Various types of valved conduit were evaluated for the hydrodynamics by a circulation system. A flow-pressure gradient Lissajous was used for the evaluation. The conduit of 10 mm in diameter had a high resistance to flow. The monocusp-valved conduit had a diastolic regurgitation (DR) at any given pressures and heart rates. The bicusp-valved conduit had a DR at higher heart rates (greater than 153/min). In this experiment, the tricusp-valved conduit with a valvular vertical versus horizontal length ratio of 2:3 had utmost favorable results under any given conditions. The valved conduits were also evaluated using sixteen mongrel dogs in which the conduit were used for the reconstruction of continuity between right ventricle and pulmonary artery. Five dogs died of bacterial infection or thrombotic obstruction. Following hemodynamic studies, which were performed in eleven dogs 1, 6, and 12 months after the operation, the dogs were sacrificed to evaluate the histological changes in the conduits. The valvular function had been satisfactory until one month, however, it was lost in 6 months because the valvular leaflets were covered with neointimae grown over them. Thin neointimae were observed both at the sites of anastomosis and at the base of the valves in dogs sacrificed at one month. They spread from the proximal anastomotic site to distal one. They were organized and it was hard to remove them manually. Thrombi were found in six dogs at the proximal anastomotic site with intimal hyperplasia. There was no calcification in Xenomedica and its degenerative change was

  8. Fluid-Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure.

    PubMed

    Toma, Milan; Jensen, Morten Ø; Einstein, Daniel R; Yoganathan, Ajit P; Cochran, Richard P; Kunzelman, Karyn S

    2016-04-01

    Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with [Formula: see text]CT. Experimental data from the in vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed leaflet dynamics, and force vectors from the in vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements enable validating and adjusting material parameters to improve the accuracy of computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.

  9. The usefulness and scientific accuracy of private sector Arabic language patient drug information leaflets.

    PubMed

    Sukkari, Sana R; Al Humaidan, Abdullah S; Sasich, Larry D

    2012-07-01

    Inadequate access to useful scientifically accurate patient information is a major cause of the inappropriate use of drugs resulting in serious personal injury and related costs to the health care system. The definition of useful scientifically accurate patient information for prescription drugs was accepted by the US Secretary of the Department of Health and Human Services in 1996 as that derived from or consistent with the US FDA approved professional product label for a drug. Previous quality content studies found that English language patient drug information leaflets distributed by US pharmacies failed to meet minimum criteria defining useful and scientifically accurate information. Evaluation forms containing the explicit elements that define useful scientifically accurate information for three drugs with known serious adverse drug reactions were created based on the current US FDA approved professional product labels. The Arabic language patient drug information leaflets for celecoxib, paroxetine, and lamotrigine were obtained locally and evaluated using a methodology similar to that used in previous quality content patient drug information studies in the US. The Arabic leaflets failed to meet the definition of useful scientifically accurate information. The celecoxib leaflet contained 30% of the required information and the paroxetine and lamotrigine leaflets contained 24% and 20%, respectively. There are several limitations to this study. The Arabic leaflets from only one commercial North American vendor were evaluated and the evaluation included a limited number of drugs. A larger study is necessary to be able to generalize these results. The study results are consistent with those of previous quality content studies of commercially available English patient drug information leaflets. The results have important implications for patients as access to a reliable source of drug information may prevent harm or limit the suffering from serious adverse drug

  10. Oenocarpus bacaba and Oenocarpus bataua Leaflets and Roots: A New Source of Antioxidant Compounds

    PubMed Central

    Leba, Louis-Jérôme; Brunschwig, Christel; Saout, Mona; Martial, Karine; Bereau, Didier; Robinson, Jean-Charles

    2016-01-01

    Native palm trees fruit from the Amazonian rainforest, Oenocarpus bacaba and Oenocarpus bataua, are very often used in the diet of local communities, but the biological activities of their roots and leaflets remain poorly known. Total phenolic content (TPC) and antioxidant activity of root and leaflet extracts from Oenocarpus bacaba and Oenocarpus bataua were assessed by using different chemical assays, the oxygèn radical absorbance capacity (ORAC), the 2,2-diphenyl-l-picrylhydrazyl (DPPH) free radical-scavenging capacity and the ferric-reducing ability of plasma (FRAP). Cellular antioxidant activity and cytotoxicity were also measured in Normal Human Dermal Fibroblasts. The polyphenolic composition of Oenocarpus extracts was investigated by LC-MSn. Oenocarpus leaflet extracts were more antioxidant than root extracts, being at least as potent as Euterpe oleracea berries known as superfruit. Oenocarpus root extracts were characterized by hydroxycinnamic acids (caffeoylquinic and caffeoylshikimic acids), while leaflet extracts contained mainly caffeoylquinic acids and C-glycosyl flavones. These results suggest that leaflets of both Oenocarpus species could be valorized as a new non-cytotoxic source of antioxidants from Amazonia, containing hydroxycinnamic acids and flavonoids, in the pharmaceutical, cosmetic or agri-food industry. PMID:27355943

  11. The enigmatic fast leaflet rotation in Desmodium motorium

    PubMed Central

    Lev-Yadun, Simcha

    2013-01-01

    I propose that the enigmatic leaflet movements in elliptical circles every few minutes of the Indian telegraph (semaphore) plant Desmodium motorium ( = D. gyrans = Hedysarum gyrans = Codariocalyx motorius), which has intrigued scientists for centuries, is a new type of butterfly or general winged arthropod mimicry by this plant. Such leaflet movement may deceive a passing butterfly searching for an un-occupied site suitable to deposit its eggs, that the plant is already occupied. It may also attract insectivorous birds, reptiles or arthropods to the plant because it looks as if it is harboring a potential prey and while they patrol there, they can find insects or other invertebrates that indeed attack the plant. The possibility that diurnal mammalian herbivores may also be deterred by these movements should not be dismissed. PMID:23603964

  12. Saddle-shaped mitral valve annuloplasty rings experience lower forces compared with flat rings.

    PubMed

    Jensen, Morten O; Jensen, Henrik; Smerup, Morten; Levine, Robert A; Yoganathan, Ajit P; Nygaard, Hans; Hasenkam, J Michael; Nielsen, Sten L

    2008-09-30

    New insight into the 3D dynamic behavior of the mitral valve has prompted a reevaluation of annuloplasty ring designs. Force balance analysis indicates correlation between annulus forces and stresses in leaflets and chords. Improving this stress distribution can intuitively enhance the durability of mitral valve repair. We tested the hypothesis that saddle-shaped annuloplasty rings have superior uniform systolic force distribution compared with a nonuniform force distribution in flat annuloplasty rings. Sixteen 80-kg pigs had a flat (n=8) or saddle-shaped (n=8) mitral annuloplasty ring implanted. Mitral annulus 3D dynamic geometry was obtained with sonomicrometry before ring insertion. Strain gauges mounted on dedicated D-shaped rigid flat and saddle-shaped annuloplasty rings provided the intraoperative force distribution perpendicular to the annular plane. Average systolic annular height to commissural width ratio before ring implantation was 14.0%+/-1.6%. After flat and saddle shaped ring implantation, the annulus was fixed in the diastolic (9.0%+/-1.0%) and systolic (14.3%+/-1.3%) configuration, respectively (P<0.01). Force accumulation was seen from the anterior (0.72N+/-0.14N) and commissural annular segments (average 1.38N+/-0.27N) of the flat rings. In these segments, the difference between the 2 types of rings was statistically significant (P<0.05). The saddle-shaped annuloplasty rings did not experience forces statistically significantly larger than zero in any annular segments. Saddle-shaped annuloplasty rings provide superior uniform annular force distribution compared to flat rings and appear to represent a configuration that minimizes out-of-plane forces that could potentially be transmitted to leaflets and chords. This may have important implications for annuloplasty ring selections.

  13. Decellularization of human donor aortic and pulmonary valved conduits using low concentration sodium dodecyl sulfate

    PubMed Central

    Vafaee, Tayyebeh; Thomas, Daniel; Desai, Amisha; Jennings, Louise M.; Berry, Helen; Rooney, Paul; Kearney, John; Fisher, John

    2017-01-01

    Abstract The clinical use of decellularized cardiac valve allografts is increasing. Long‐term data will be required to determine whether they outperform conventional cryopreserved allografts. Valves decellularized using different processes may show varied long‐term outcomes. It is therefore important to understand the effects of specific decellularization technologies on the characteristics of donor heart valves. Human cryopreserved aortic and pulmonary valved conduits were decellularized using hypotonic buffer, 0.1% (w/v) sodium dodecyl sulfate and nuclease digestion. The decellularized tissues were compared to cellular cryopreserved valve tissues using histology, immunohistochemistry, quantitation of total deoxyribose nucleic acid, collagen and glycosaminoglycan content, in vitro cytotoxicity assays, uniaxial tensile testing and subcutaneous implantation in mice. The decellularized tissues showed no histological evidence of cells or cell remnants and >97% deoxyribose nucleic acid removal in all regions (arterial wall, muscle, leaflet and junction). The decellularized tissues retained collagen IV and von Willebrand factor staining with some loss of fibronectin, laminin and chondroitin sulfate staining. There was an absence of major histocompatibility complex Class I staining in decellularized pulmonary valve tissues, with only residual staining in isolated areas of decellularized aortic valve tissues. The collagen content of the tissues was not decreased following decellularization however the glycosaminoglycan content was reduced. Only moderate changes in the maximum load to failure of the tissues were recorded postdecellularization. The decellularized tissues were noncytotoxic in vitro, and were biocompatible in vivo in a mouse subcutaneous implant model. The decellularization process will now be translated into a good manufacturing practices‐compatible process for donor cryopreserved valves with a view to future clinical use. Copyright © 2016 The Authors

  14. The long non-coding HOTAIR is modulated by cyclic stretch and WNT/β-CATENIN in human aortic valve cells and is a novel repressor of calcification genes.

    PubMed

    Carrion, Katrina; Dyo, Jeffrey; Patel, Vishal; Sasik, Roman; Mohamed, Salah A; Hardiman, Gary; Nigam, Vishal

    2014-01-01

    Aortic valve calcification is a significant and serious clinical problem for which there are no effective medical treatments. Individuals born with bicuspid aortic valves, 1-2% of the population, are at the highest risk of developing aortic valve calcification. Aortic valve calcification involves increased expression of calcification and inflammatory genes. Bicuspid aortic valve leaflets experience increased biomechanical strain as compared to normal tricuspid aortic valves. The molecular pathogenesis involved in the calcification of BAVs are not well understood, especially the molecular response to mechanical stretch. HOTAIR is a long non-coding RNA (lncRNA) that has been implicated with cancer but has not been studied in cardiac disease. We have found that HOTAIR levels are decreased in BAVs and in human aortic interstitial cells (AVICs) exposed to cyclic stretch. Reducing HOTAIR levels via siRNA in AVICs results in increased expression of calcification genes. Our data suggest that β-catenin is a stretch responsive signaling pathway that represses HOTAIR. This is the first report demonstrating that HOTAIR is mechanoresponsive and repressed by WNT β-catenin signaling. These findings provide novel evidence that HOTAIR is involved in aortic valve calcification.

  15. Readability Statistics of Patient Information Leaflets in a Speech and Language Therapy Department

    ERIC Educational Resources Information Center

    Pothier, Louise; Day, Rachael; Harris, Catherine; Pothier, David D.

    2008-01-01

    Background: Information leaflets are commonly used in Speech and Language Therapy Departments. Despite widespread use, they can be of variable quality. Aims: To revise current departmental leaflets using the National Health Service (NHS) Toolkit for Producing Patient Information and to test the effect that this has on the readability scores of the…

  16. Mitral Valve Structure in Addition to Myocardial Viability Determines the Outcome of Functional Mitral Regurgitation After Coronary Artery Bypass Grafting.

    PubMed

    Yoshida, Shohei; Fukushima, Satsuki; Miyagawa, Shigeru; Nakamura, Teruya; Yoshikawa, Yasushi; Hata, Hiroki; Saito, Shunsuke; Yoshioka, Daisuke; Domae, Keitaro; Kashiyama, Noriyuki; Yamamoto, Kouji; Shintani, Ayumi; Nakatani, Satoshi; Toda, Koichi; Sawa, Yoshiki

    2017-10-25

    Coronary artery bypass grafting (CABG) reduces functional mitral regurgitation (MR) associated with ischemic heart disease, although the predictive factors or mechanisms of reversibility of functional MR after CABG are not fully understood.We investigated whether mitral valve structure is associated with the outcome of functional MR after CABG.Methods and Results:From a consecutive series of 98 patients with mild-moderate functional MR preoperatively who underwent isolated CABG, we enrolled 66 patients who were followed up for >1 year postoperatively using echocardiography. The degree of MR was reduced in 34 patients (52%) postoperatively, in association with a lower rate of in-hospital treatment for cardiac failure in the long term, compared with the 32 patients (48%) with residual MR postoperatively. The patients with reduced MR postoperatively had longer estimated coaptation length and more anteriorly or centrally directed MR jets than those without reduced MR. On statistical analysis, the addition of estimated coaptation length and jet direction to the reported predictors (ejection fraction, left ventricular end-diastolic dimension, and tenting height) more accurately predicted changes in post-CABG MR than the reported 3 factors alone. Residual MR was associated with the emergence of congestive heart failure in the long term after CABG. A specific mitral valve structure, such as large mitral leaflet size or predominant tethering of the posterior leaflet, was a predictive factor for the reversibility of post-CABG functional MR.

  17. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Practitioner and lay perspectives of the service provision of nutrition information leaflets in primary care.

    PubMed

    McClinchy, Jane; Dickinson, Angela; Barron, Duncan; Thomas, Hilary

    2011-12-01

    In primary care, leaflets are often used to communicate health information. Increasingly, primary healthcare practitioners need to provide dietary advice. There is limited research exploring how nutrition information leaflets are used in primary care. The present study explored practitioner and lay experiences with respect to providing and receiving nutrition information in primary care, focusing in particular on the use of leaflets for nutrition information. A qualitative design was used incorporating focus groups with 57 practitioners based at seven general practitioner practices and a purposive sample of 30 lay participants attending six Consumer Health Organisations within one primary care trust. Focus groups were taped and transcribed verbatim and data were analysed thematically, assisted by computer software n6® (QSR International Pty Ltd, Melbourne, Australia). Practitioners discussed barriers to giving nutritional advice, access to leaflets, lay receptiveness to advice and their perceptions about the value of leaflets to lay people. Food was not considered in terms of its nutritional components by lay participants and the need for nutritional information was not perceived to be relevant until they had received a medical diagnosis. Lay participants discussed the importance of receiving nutritional advice relating to their medical diagnosis and the altered status of written information that was delivered personally. Practitioner and lay groups suggested improvements to ensure that nutritional advice be supported by relevant and appropriate written information. This research has underlined the continuing importance of nutrition information leaflets and concludes that there is particular value in involving lay participants in the development of nutrition information leaflets. © 2011 The Authors. Journal of Human Nutrition and Dietetics © 2011 The British Dietetic Association Ltd.

  19. Creation New Patient Information Leaflets with Diabetes by Pharmacists and Assesment Conducted by Patients.

    PubMed

    Arai, Motoharu; Maeda, Kazuto; Satoh, Hiroki; Miki, Akiko; Sawada, Yasufumi

    2016-10-01

    We created a draft of new patient information leaflets to ensure patients' proper use of drugs and to highlight safety issues and improvement plans extracted and proposed by small group discussions (SGD) with pharmacists. A total of 3 SGDs (participants: 15 pharmacists) were conducted with the aim of improving patient information leaflets for oral diabetes drugs. First, the disadvantages and advantages of the current instructions as well as requests for ideal patient information leaflets were obtained from participants. Conventional patient information leaflets that could be improved were useful to understand drug efficacy, adverse effects, and instructions for daily consumption of medicines, and to encourage patients to re-check drugs at home and inform their family of the measures to be taken in the case of adverse effects from the standpoint of patients. However, some disadvantages arose; for example, the instructions were difficult to read because of small lettering and illustrations and too much text. It was not tailored for individual patients, and descriptions about serious adverse effects caused patients much anxiety. Therefore, we have created a draft of new patient information leaflets with diabetes that are simpler and easier to understand and use concise wording and illustrations that are impactful.

  20. Traumatic Tricuspid Insufficiency Requiring Valve Repair in an Acute Setting.

    PubMed

    Enomoto, Yoshinori; Sudo, Yoshio; Sueta, Tomonori

    2015-01-01

    Tricuspid insufficiency due to penetrating cardiac trauma is rare. Patients with tricuspid insufficiency due to trauma can tolerate this abnormality for months or even years. We report a case of a 66-year-old female with penetrating cardiac trauma on the right side of her heart that required tricuspid valve repair in an acute setting. She sustained cut and stab wounds on her bilateral forearms and in the neck and epigastric region. She had cardiac tamponade and developed pulseless electrical activity, which required emergency surgery. The right ventricle and superior vena cava were dissected approximately 5 cm and 2 cm, respectively. After these wounds had been repaired, the patient's inability to wean from cardiopulmonary bypass suggested rightsided heart failure; transesophageal echocardiography revealed tricuspid insufficiency. Right atriotomy was performed, and a detailed examination revealed that the tricuspid valve septal leaflet was split in two. There was also an atrial septal injury that created a connection with the left atrium; these injuries were not detected from the right ventricular wound. After repair, weaning from cardiopulmonary bypass with mild tricuspid insufficiency was achieved, and she recovered uneventfully. This case emphasized the importance of thoroughly investigating intracardiac injury and transesophageal echocardiography.

  1. Learning curve analysis of mitral valve repair using telemanipulative technology.

    PubMed

    Charland, Patrick J; Robbins, Tom; Rodriguez, Evilio; Nifong, Wiley L; Chitwood, Randolph W

    2011-08-01

    To determine if the time required to perform mitral valve repairs using telemanipulation technology decreases with experience and how that decrease is influenced by patient and procedure variables. A single-center retrospective review was conducted using perioperative and outcomes data collected contemporaneously on 458 mitral valve repair surgeries using telemanipulative technology. A regression model was constructed to assess learning with this technology and predict total robot time using multiple predictive variables. Statistical analysis was used to determine if models were significantly useful, to rule out correlation between predictor variables, and to identify terms that did not contribute to the prediction of total robot time. We found a statistically significant learning curve (P < .01). The institutional learning percentage∗ derived from total robot times† for the first 458 recorded cases of mitral valve repair using telemanipulative technology is 95% (R(2) = .40). More than one third of the variability in total robot time can be explained through our model using the following variables: type of repair (chordal procedures, ablations, and leaflet resections), band size, use of clips alone in band implantation, and the presence of a fellow at bedside (P < .01). Learning in mitral valve repair surgery using telemanipulative technology occurs at the East Carolina Heart Institute according to a logarithmic curve, with a learning percentage of 95%. From our regression output, we can make an approximate prediction of total robot time using an additive model. These metrics can be used by programs for benchmarking to manage the implementation of this new technology, as well as for capacity planning, scheduling, and capital budget analysis. Copyright © 2011 The American Association for Thoracic Surgery. All rights reserved.

  2. Embryonic Ethanol Exposure Dysregulates BMP and Notch Signaling, Leading to Persistent Atrio-Ventricular Valve Defects in Zebrafish

    PubMed Central

    Sarmah, Swapnalee; Muralidharan, Pooja

    2016-01-01

    Fetal alcohol spectrum disorder (FASD), birth defects associated with ethanol exposure in utero, includes a wide spectrum of congenital heart defects (CHDs), the most prevalent of which are septal and conotruncal defects. Zebrafish FASD model was used to dissect the mechanisms underlying FASD-associated CHDs. Embryonic ethanol exposure (3–24 hours post fertilization) led to defects in atrio-ventricular (AV) valvulogenesis beginning around 37 hpf, a morphogenetic event that arises long after ethanol withdrawal. Valve leaflets of the control embryos comprised two layers of cells confined at the compact atrio-ventricular canal (AVC). Ethanol treated embryos had extended AVC and valve forming cells were found either as rows of cells spanning the AVC or as unorganized clusters near the AV boundary. Ethanol exposure reduced valve precursors at the AVC, but some ventricular cells in ethanol treated embryos exhibited few characteristics of valve precursors. Late staged larvae and juvenile fish exposed to ethanol during embryonic development had faulty AV valves. Examination of AVC morphogenesis regulatory networks revealed that early ethanol exposure disrupted the Bmp signaling gradient in the heart during valve formation. Bmp signaling was prominent at the AVC in controls, but ethanol-exposed embryos displayed active Bmp signaling throughout the ventricle. Ethanol exposure also led to mislocalization of Notch signaling cells in endocardium during AV valve formation. Normally, highly active Notch signaling cells were organized at the AVC. In ethanol-exposed embryos, highly active Notch signaling cells were dispersed throughout the ventricle. At later stages, ethanol-exposed embryos exhibited reduced Wnt/β-catenin activity at the AVC. We conclude that early embryonic ethanol exposure alters Bmp, Notch and other signaling activities during AVC differentiation leading to faulty valve morphogenesis and valve defects persist in juvenile fish. PMID:27556898

  3. Embryonic Ethanol Exposure Dysregulates BMP and Notch Signaling, Leading to Persistent Atrio-Ventricular Valve Defects in Zebrafish.

    PubMed

    Sarmah, Swapnalee; Muralidharan, Pooja; Marrs, James A

    2016-01-01

    Fetal alcohol spectrum disorder (FASD), birth defects associated with ethanol exposure in utero, includes a wide spectrum of congenital heart defects (CHDs), the most prevalent of which are septal and conotruncal defects. Zebrafish FASD model was used to dissect the mechanisms underlying FASD-associated CHDs. Embryonic ethanol exposure (3-24 hours post fertilization) led to defects in atrio-ventricular (AV) valvulogenesis beginning around 37 hpf, a morphogenetic event that arises long after ethanol withdrawal. Valve leaflets of the control embryos comprised two layers of cells confined at the compact atrio-ventricular canal (AVC). Ethanol treated embryos had extended AVC and valve forming cells were found either as rows of cells spanning the AVC or as unorganized clusters near the AV boundary. Ethanol exposure reduced valve precursors at the AVC, but some ventricular cells in ethanol treated embryos exhibited few characteristics of valve precursors. Late staged larvae and juvenile fish exposed to ethanol during embryonic development had faulty AV valves. Examination of AVC morphogenesis regulatory networks revealed that early ethanol exposure disrupted the Bmp signaling gradient in the heart during valve formation. Bmp signaling was prominent at the AVC in controls, but ethanol-exposed embryos displayed active Bmp signaling throughout the ventricle. Ethanol exposure also led to mislocalization of Notch signaling cells in endocardium during AV valve formation. Normally, highly active Notch signaling cells were organized at the AVC. In ethanol-exposed embryos, highly active Notch signaling cells were dispersed throughout the ventricle. At later stages, ethanol-exposed embryos exhibited reduced Wnt/β-catenin activity at the AVC. We conclude that early embryonic ethanol exposure alters Bmp, Notch and other signaling activities during AVC differentiation leading to faulty valve morphogenesis and valve defects persist in juvenile fish.

  4. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    PubMed

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (<12 kg) may necessitate a redundant lead remaining looped in the right atrium for appropriate sensing and pacing. This report documented acquired tricuspid valve stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Evaluating the application of research-based guidance to the design of an emergency preparedness leaflet.

    PubMed

    Hellier, E; Edworthy, J; Newbold, L; Titchener, K; Tucker, M; Gabe-Thomas, E

    2014-09-01

    Guidelines for the design of emergency communications were derived from primary research and interrogation of the literature. The guidelines were used to re-design a nuclear emergency preparedness leaflet routinely distributed to households in the local area. Pre-test measures of memory for, and self-reported understanding of, nuclear safety information were collected. The findings revealed high levels of non-receipt of the leaflet, and among those who did receive it, memory for safety advice was poor. Subjective evaluations of the trial leaflet suggested that it was preferred and judged easier to understand than the original. Objective measures of memory for the two leaflets were also recorded, once after the study period, and again one week or four weeks later. Memory for the advice was better, at all time periods, when participants studied the trial leaflet. The findings showcase evaluation of emergency preparedness literature and suggest that extant research findings can be applied to the design of communications to improve memory and understandability. Studies are described that showcase the use of research-based guidelines to design emergency communications and provide both subjective and objective data to support designing emergency communications in this way. In addition, the research evaluates the effectiveness of emergency preparedness leaflets that are routinely distributed to households. This work is of relevance to academics interested in risk communication and to practitioners involved in civil protection and emergency preparedness. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  6. Low literacy and written drug information: information-seeking, leaflet evaluation and preferences, and roles for images.

    PubMed

    van Beusekom, Mara M; Grootens-Wiegers, Petronella; Bos, Mark J W; Guchelaar, Henk-Jan; van den Broek, Jos M

    2016-12-01

    Background Low-literate patients are at risk to misinterpret written drug information. For the (co-) design of targeted patient information, it is key to involve this group in determining their communication barriers and information needs. Objective To gain insight into how people with low literacy use and evaluate written drug information, and to identify ways in which they feel the patient leaflet can be improved, and in particular how images could be used. Setting Food banks and an education institution for Dutch language training in the Netherlands. Method Semi-structured focus groups and individual interviews were held with low-literate participants (n = 45). The thematic framework approach was used for analysis to identify themes in the data. Main outcome measure Low-literate people's experience with patient information leaflets, ideas for improvements, and perceptions on possible uses for visuals. Results Patient information leaflets were considered discouraging to use, and information difficult to find and understand. Many rely on alternative information sources. The leaflet should be shorter, and improved in terms of organisation, legibility and readability. Participants thought images could increase the leaflet's appeal, help ask questions, provide an overview, help understand textual information, aid recall, reassure, and even lead to increased confidence, empowerment and feeling of safety. Conclusion Already at the stages of paying attention to the leaflet and maintaining interest in the message, low-literate patients experience barriers in the communication process through written drug information. Short, structured, visual/textual explanations can lower the motivational threshold to use the leaflet, improve understanding, and empower the low-literate target group.

  7. Non-functional tricuspid valve disease.

    PubMed

    Adler, Dale S

    2017-05-01

    Only 75% of severe tricuspid regurgitation is classified as functional, or related primarily to pulmonary hypertension, right ventricular dysfunction, or a combination of both. Non-functional tricuspid regurgitation occurs when there is damage to the tricuspid leaflets, chordae, papillary muscles, or annulus, independent of right ventricular dysfunction or pulmonary hypertension. The entities that cause non-functional tricuspid regurgitation include rheumatic and myxomatous disease, acquired and genetic connective tissue disorders, endocarditis, sarcoid, pacing, RV biopsy, blunt trauma, radiation, carcinoid, ergot alkaloids, dopamine agonists, fenfluramine, cardiac tumors, atrial fibrillation, and congenital malformations. Over time, severe tricuspid regurgitation that is initially non-functional, can blend into functional tricuspid regurgitation, related to progressive right ventricular dysfunction. Symptoms and signs, including a falling right ventricular ejection fraction, cardiac cirrhosis, ascites, esophageal varices, and anasarca, may occur insidiously and late, but are associated with substantial morbidity and mortality. Attempted valve repair or replacement at late stages carries a high mortality. Crucial to following patients with severe non-functional tricuspid regurgitation is attention to echo quantification of the tricuspid regurgitation and right ventricular function, patient symptoms, and the physical examination.

  8. Traumatic Tricuspid Regurgitation.

    PubMed

    Cheng, Yan; Yao, Lei; Wu, Shengjun

    2017-05-31

    Traumatic tricuspid regurgitation is a rare and progressive disease. Early diagnosis and surgical valve repair are very important. A 57-year-old male was referred to our hospital with a history of blunt chest trauma. Three-dimensional echocardiography showed severe tricuspid regurgitation and demonstrated two main anterior leaflet chordaes of the tricuspid valve rupture and the whole anterior leaflet prolapsed. The diagnosis was severe tricuspid regurgitation due to leaflet chordae rupture secondary to blunt chest trauma. Surgical repair of the tricuspid valve was performed in this patient. At 3-month follow-up, the right ventricle was decreased in size with significantly improved right ventricular function. The signs and symptoms of right heart failure were relieved. In this case, 3-dimensional transthoracic echocardiography enabled fast and non-invasive evaluation of the spatial destruction of the tricuspid valve and subvalvular apparatus to assist in the planning of valve repair.

  9. Selective propensity of bovine jugular vein material to bacterial adhesions: An in-vitro study.

    PubMed

    Jalal, Zakaria; Galmiche, Louise; Lebeaux, David; Villemain, Olivier; Brugada, Georgia; Patel, Mehul; Ghigo, Jean-Marc; Beloin, Christophe; Boudjemline, Younes

    2015-11-01

    Percutaneous pulmonary valve implantation (PPVI) using Melody valve made of bovine jugular vein is safe and effective. However, infective endocarditis has been reported for unclear reasons. We sought to assess the impact of valvular substrates on selective bacterial adhesion. Three valved stents (Melody valve, homemade stents with bovine and porcine pericardium) were tested in-vitro for bacterial adhesion using Staphylococcus aureus and Streptococcus sanguinis strains. Bacterial adhesion was higher on bovine jugular venous wall for S. aureus and on Melody valvular leaflets for S. sanguinis in control groups and significantly increased in traumatized Melody valvular leaflets with both bacteria (traumatized vs non traumatized: p=0.05). Bacterial adhesion was lower on bovine pericardial leaflets. Selective adhesion of S. aureus and S. sanguinis pathogenic strains to Melody valve tissue was noted on healthy tissue and increased after implantation procedural steps. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Repair for mitral stenosis due to pannus formation after Duran ring annuloplasty.

    PubMed

    Song, Seunghwan; Cho, Seong Ho; Yang, Ji-Hyuk; Park, Pyo Won

    2010-12-01

    Mitral stenosis after mitral repair with using an annuloplasty ring is not common and it is almost always due to pannus formation. Mitral valve replacement was required in most of the previous cases of pannus covering the mitral valve leaflet, which could not be stripped off without damaging the valve leaflets. In two cases, we removed the previous annuloplasty ring and pannus without leaflet injury, and we successfully repaired the mitral valve. During the follow-up of 4 months and 39 months respectively, we observed improvement of the patients' symptoms and good valvular function. Redo mitral repair may be a possible method for treating mitral stenosis due to pannus formation after ring annuloplasty. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Matrix metalloproteinase inhibitor, doxycycline and progression of calcific aortic valve disease in hyperlipidemic mice.

    PubMed

    Jung, Jae-Joon; Razavian, Mahmoud; Kim, Hye-Yeong; Ye, Yunpeng; Golestani, Reza; Toczek, Jakub; Zhang, Jiasheng; Sadeghi, Mehran M

    2016-09-13

    Calcific aortic valve disease (CAVD) is the most common cause of aortic stenosis. Currently, there is no non-invasive medical therapy for CAVD. Matrix metalloproteinases (MMPs) are upregulated in CAVD and play a role in its pathogenesis. Here, we evaluated the effect of doxycycline, a nonselective MMP inhibitor on CAVD progression in the mouse. Apolipoprotein (apo)E(-/-) mice (n = 20) were fed a Western diet (WD) to induce CAVD. After 3 months, half of the animals was treated with doxycycline, while the others continued WD alone. After 6 months, we evaluated the effect of doxycycline on CAVD progression by echocardiography, MMP-targeted micro single photon emission computed tomography (SPECT)/computed tomography (CT), and tissue analysis. Despite therapeutic blood levels, doxycycline had no significant effect on MMP activation, aortic valve leaflet separation or flow velocity. This lack of effect on in vivo images was confirmed on tissue analysis which showed a similar level of aortic valve gelatinase activity, and inflammation between the two groups of animals. In conclusion, doxycycline (100 mg/kg/day) had no effect on CAVD progression in apoE(-/-) mice with early disease. Studies with more potent and specific inhibitors are needed to establish any potential role of MMP inhibition in CAVD development and progression.

  12. Overcoming the knowledge-behavior gap: The effect of evidence-based HPV vaccination leaflets on understanding, intention, and actual vaccination decision.

    PubMed

    Wegwarth, O; Kurzenhäuser-Carstens, S; Gigerenzer, G

    2014-03-10

    Informed decision making requires transparent and evidence-based (=balanced) information on the potential benefit and harms of medical preventions. An analysis of German HPV vaccination leaflets revealed, however, that none met the standards of balanced risk communication. We surveyed a sample of 225 girl-parent pairs in a before-after design on the effects of balanced and unbalanced risk communication on participants' knowledge about cervical cancer and the HPV vaccination, their perceived risk, their intention to have the vaccine, and their actual vaccination decision. The balanced leaflet increased the number of participants who were correctly informed about cervical cancer and the HPV vaccine by 33 to 66 absolute percentage points. In contrast, the unbalanced leaflet decreased the number of participants who were correctly informed about these facts by 0 to 18 absolute percentage points. Whereas the actual uptake of the HPV vaccination 14 months after the initial study did not differ between the two groups (22% balanced leaflet vs. 23% unbalanced leaflet; p=.93, r=.01), the originally stated intention to have the vaccine reliably predicted the actual vaccination decision for the balanced leaflet group only (concordance between intention and actual uptake: 97% in the balanced leaflet group, rs=.92, p=.00; 60% in the unbalanced leaflet group, rs=.37, p=.08). In contrast to a unbalanced leaflet, a balanced leaflet increased people's knowledge of the HPV vaccination, improved perceived risk judgments, and led to an actual vaccination uptake, which first was robustly predicted by people's intention and second did not differ from the uptake in the unbalanced leaflet group. These findings suggest that balanced reporting about HPV vaccination increases informed decisions about whether to be vaccinated and does not undermine actual uptake. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Carotenoids Co-Localize with Hydroxyapatite, Cholesterol, and Other Lipids in Calcified Stenotic Aortic Valves. Ex Vivo Raman Maps Compared to Histological Patterns

    PubMed Central

    Bonetti, A.; Bonifacio, A.; Mora, A. Della; Livi, U.; Marchini, M.; Ortolani, F.

    2015-01-01

    Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potential precocious diagnostic use. Cryosections from surgically explanted stenotic aortic valves (n=4) were studied matching Raman maps against specific histological patterns. Raman maps revealed the presence of phospholipids/triglycerides and cholesterol, which showed spatial overlapping with one another and Raman-identified hydroxyapatite. Moreover, the Raman patterns correlated with those displayed by both von-Kossa-calcium- and Nile-blue-stained serial cryosections. Raman analysis also provided the first identification of carotenoids, which co-localized with the identified lipid moieties. Additional fit concerned the distribution of collagen and elastin. The good correlation of Raman maps with high-affinity staining patterns proved that Raman microspectroscopy is a reliable tool in evaluating calcification degree, alteration/displacement of extracellular matrix components, and accumulation rate of different lipid forms in calcified heart valves. In addition, the novel identification of carotenoids supports the concept that valve stenosis is an atherosclerosis-like valve lesion, consistently with their previous Raman microspectroscopical identification inside atherosclerotic plaques. PMID:26150160

  14. Carotenoids co-localize with hydroxyapatite, cholesterol, and other lipids in calcified stenotic aortic valves. Ex vivo Raman maps compared to histological patterns.

    PubMed

    Bonetti, A; Bonifacio, A; Della Mora, A; Livi, U; Marchini, M; Ortolani, F

    2015-04-20

    Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potential precocious diagnostic use. Cryosections from surgically explanted stenotic aortic valves (n=4) were studied matching Raman maps against specific histological patterns. Raman maps revealed the presence of phospholipids/triglycerides and cholesterol, which showed spatial overlapping with one another and Raman-identified hydroxyapatite. Moreover, the Raman patterns correlated with those displayed by both von-Kossa-calcium- and Nile-blue-stained serial cryosections. Raman analysis also provided the first identification of carotenoids, which co-localized with the identified lipid moieties. Additional fit concerned the distribution of collagen and elastin. The good correlation of Raman maps with high-affinity staining patterns proved that Raman microspectroscopy is a reliable tool in evaluating calcification degree, alteration/displacement of extracellular matrix components, and accumulation rate of different lipid forms in calcified heart valves. In addition, the novel identification of carotenoids supports the concept that valve stenosis is an atherosclerosis-like valve lesion, consistently with their previous Raman microspectroscopical identification inside atherosclerotic plaques.

  15. Finite element modeling of mitral leaflet tissue using a layered shell approximation

    PubMed Central

    Ratcliffe, Mark B.; Guccione, Julius M.

    2012-01-01

    The current study presents a finite element model of mitral leaflet tissue, which incorporates the anisotropic material response and approximates the layered structure. First, continuum mechanics and the theory of layered composites are used to develop an analytical representation of membrane stress in the leaflet material. This is done with an existing anisotropic constitutive law from literature. Then, the concept is implemented in a finite element (FE) model by overlapping and merging two layers of transversely isotropic membrane elements in LS-DYNA, which homogenizes the response. The FE model is then used to simulate various biaxial extension tests and out-of-plane pressure loading. Both the analytical and FE model show good agreement with experimental biaxial extension data, and show good mutual agreement. This confirms that the layered composite approximation presented in the current study is able to capture the exponential stiffening seen in both the circumferential and radial directions of mitral leaflets. PMID:22971896

  16. 3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation.

    PubMed

    Mediratta, Anuj; Addetia, Karima; Yamat, Megan; Moss, Joshua D; Nayak, Hemal M; Burke, Martin C; Weinert, Lynn; Maffessanti, Francesco; Jeevanandam, Valluvan; Mor-Avi, Victor; Lang, Roberto M

    2014-04-01

    This study sought to: 1) determine the feasibility of using 3-dimensional transthoracic echocardiography (3D TTE) in patients with implantable cardiac resynchronization devices, pacemakers, and defibrillators to visualize the device leads in the right heart and their position relative to the tricuspid valve leaflets; 2) determine the prevalence of different lead positions; and 3) study the relationship between lead location and tricuspid regurgitation (TR) severity. Pacemaker, defibrillator, and cardiac resynchronization device implantation is currently guided by fluoroscopy, not allowing targeted lead positioning relative to the tricuspid valve leaflets. These leads have been reported to cause TR of variable degrees, but echocardiography is not routinely used to elucidate the mechanisms of lead interference with tricuspid valve leaflets in individual patients. 3D TTE full-volume images of the right ventricle and/or zoomed images of the tricuspid valve were obtained in 121 patients with implanted devices. Images were viewed offline to determine the position of the device-lead relative to the tricuspid valve leaflets. Severity of TR was estimated on the basis of vena contracta measurements. 3D TTE clearly depicted lead position in 90% of patients. The right ventricular lead was impinging on either the posterior (20%) or septal (23%) leaflet or was not interfering with leaflet motion (53%) when positioned near the posteroseptal commissure or in the central portion of the tricuspid valve orifice. In the remaining patients, leads were impinging on the anterior leaflet (4%) or positioned in either the anteroposterior or anteroseptal commissure (3%). Leads interfering with normal leaflet mobility were associated with more TR than nonimpinging leads (vena contracta: median 0.62 cm [1st and 3rd quartiles: 0.51, 0.84 cm] vs. 0.27 cm [1st and 3rd quartiles: 0.00, 0.48 cm]; p < 0.001). 3D TTE showed a clear association between device lead position and TR. To minimize TR

  17. A comparison of the clinical, haemodynamic and angiographic features in right ventricular endomyocardial fibrosis and Ebstein's anomaly of the tricuspid valve.

    PubMed

    Balakrishnan, K G; Sapru, R P; Sasidharan, K; Venkitachalam, C G

    1982-01-01

    The clinical, haemodynamic and angiographic features of 18 patients with right ventricular endomyocardial fibrosis (RVEMF) and 8 patients with Ebstein's anomaly of the tricuspid valve (EATV) have been compared. Diagnosis was confirmed by selective angiography. The position of the tricuspid annulus was identified from selective right ventricular angiograms and confirmed by selective right coronary angiography. In 83% of RVEMF patients the tricuspid annulus was displaced to the left of the spine. A false impression of displacement of the tricuspid leaflet can thus be created. However, a tricuspid leaflet displaced away from the tricuspid annulus was found only in patients with EATV. A considerable overlap exists between the wide spectrum of clinical presentations of the two conditions. Helpful distinguishing features that favour EATV were, the presence of a scratchy diastolic murmur and polyphasic QRS complexes in the ECG. Atrial fibrillation in the ECG, and myocardial calcification or pericardial effusion, whenever present, favour RVEMF.

  18. A descriptive study of the readability of patient information leaflets designed by nurses.

    PubMed

    Mumford, M E

    1997-11-01

    Written patient information materials can be valuable communication tools for teaching and reinforcing the verbal message, especially in the present climate of today's health service where patients are in hospital for such short times. They are only useful if the patient is able to read and understand them, otherwise they become an expensive waste of resources. Various studies have shown that many healthcare information leaflets are written at university or postgraduate level and would cause problems with understanding for many people reading them. This study set out to examine the readability of nurse-designed written information leaflets using the Flesch Reading Ease score and the FOG and SMOG readability formulae. This descriptive study used a sample of 24 leaflets designed by trained nurses in a large teaching hospital. The results produced a mean grade of 11.3 with a range of 8.9 to 14.8. This was similar to the results of other studies and meant that patients may have difficulty comprehending the information. It would appear that little progress has been made in 40 years in this area and potential reasons are discussed. Advantages and disadvantages of readability formulae and other guidelines available for developing information leaflets are explored. Recommendations for further research are made.

  19. Development of Prescription Drug Information Leaflets: Impact of Cognitive Effort and Patient Involvement on Prescription Medication Information Processing.

    PubMed

    Patel, Harshali K; Bapat, Shweta S; Bhansali, Archita H; Sansgiry, Sujit S

    2018-01-01

    The objective of this study was to develop a one-page (1-page) prescription drug information leaflet (PILs) and assess their impact on the information processing variables, across 2 levels of patient involvement. One-page PILs were developed using cognitive principles to lower mental effort and improve comprehension. An experimental, 3 × 2 repeated measures study was conducted to determine the impact of cognitive effort, manipulated using leaflet type on comprehension across 2 levels (high/low) of patient involvement. Adults (≥18 years) in a university setting in Houston were recruited for the study. Each participant was exposed to 3 different types of prescription drug information leaflet (the current practice, preexisting 1-page text-only, and 1-page PILs) for the 3 drugs (Celebrex, Ventolin HFA, Prezista) for a given involvement scenario. A prevalidated survey instrument was used to measure product knowledge, attitude toward leaflet, and intention to read. Multivariate analysis of variance indicated significant positive effect of cognitive effort, involvement, and their interaction effect across all measured variables. Mean scores for product knowledge, attitude toward leaflet, and intention to read were highest for PILs ( P < .001), indicating that PILs exerted lowest cognitive effort. Univariate and post hoc analysis indicate that product knowledge significantly increases with high involvement. Patients reading PILs have higher comprehension compared with the current practice and text-only prototype leaflets evaluated. Higher levels of involvement further improve participant knowledge about the drug, increase their intention to read the leaflet, and change their attitude toward the leaflet. Implementation of PILs would improve information processing for consumers by reducing their cognitive effort.

  20. A new definition for an old entity: improved definition of mitral valve prolapse using three-dimensional echocardiography and color-coded parametric models.

    PubMed

    Addetia, Karima; Mor-Avi, Victor; Weinert, Lynn; Salgo, Ivan S; Lang, Roberto M

    2014-01-01

    Differentiating between mitral valve (MV) prolapse (MVP) and MV billowing (MVB) on two-dimensional echocardiography is challenging. The aim of this study was to test the hypothesis that color-coded models of maximal leaflet displacement from the annular plane into the atrium derived from three-dimensional transesophageal echocardiography would allow discrimination between these lesions. Three-dimensional transesophageal echocardiographic imaging of the MV was performed in 50 patients with (n = 38) and without (n = 12) degenerative MV disease. Definitive diagnosis of MVP versus MVB was made using inspection of dynamic three-dimensional renderings and multiple two-dimensional cut planes extracted from three-dimensional data sets. This was used as a reference standard to test an alternative approach, wherein the color-coded parametric models were inspected for integrity of the coaptation line and location of the maximally displaced portion of the leaflet. Diagnostic interpretations of these models by two independent readers were compared with the reference standard. In all cases of MVP, the color-coded models depicted loss of integrity of the coaptation line and maximal leaflet displacement extending to the coaptation line. MVB was depicted by preserved leaflet apposition with maximal displacement away from the coaptation line. Interpretation of the 50 color-coded models by novice readers took 5 to 10 min and resulted in good agreement with the reference technique (κ = 0.81 and κ = 0.73 for the two readers). Three-dimensional color-coded models provide a static display of MV leaflet displacement, allowing differentiation between MVP and MVB, without the need to inspect multiple planes and while taking into account the saddle shape of the mitral annulus. Copyright © 2014 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  1. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  2. A new generation of high flex life polyurethane urea for polymer heart valve--studies on in vivo biocompatibility and biodurability.

    PubMed

    Thomas, Vinoy; Jayabalan, Muthu

    2009-04-01

    Development of new generation high flex life polyurethane urea (HFL18-PU) with appropriate elastic modulus, biocompatibility, blood compatibility, resistant to calcification, and biodurability for the long-term use as cardiac device is still a challenge. This study reports the development of a fully aliphatic, ether-free physically cross-linked and low elastic modulus (6.841 +/- 0.27 MPa) polyurethane urea having in vivo biostability, in vivo biocompatibility and high flex-life (721 +/- 30 million cycles) that can satisfy the requirements for the fabrication of tri-leaflet heart valve. Copyright 2008 Wiley Periodicals, Inc.

  3. High-resolution subject-specific mitral valve imaging and modeling: experimental and computational methods.

    PubMed

    Toma, Milan; Bloodworth, Charles H; Einstein, Daniel R; Pierce, Eric L; Cochran, Richard P; Yoganathan, Ajit P; Kunzelman, Karyn S

    2016-12-01

    The diversity of mitral valve (MV) geometries and multitude of surgical options for correction of MV diseases necessitates the use of computational modeling. Numerical simulations of the MV would allow surgeons and engineers to evaluate repairs, devices, procedures, and concepts before performing them and before moving on to more costly testing modalities. Constructing, tuning, and validating these models rely upon extensive in vitro characterization of valve structure, function, and response to change due to diseases. Micro-computed tomography ([Formula: see text]CT) allows for unmatched spatial resolution for soft tissue imaging. However, it is still technically challenging to obtain an accurate geometry of the diastolic MV. We discuss here the development of a novel technique for treating MV specimens with glutaraldehyde fixative in order to minimize geometric distortions in preparation for [Formula: see text]CT scanning. The technique provides a resulting MV geometry which is significantly more detailed in chordal structure, accurate in leaflet shape, and closer to its physiological diastolic geometry. In this paper, computational fluid-structure interaction (FSI) simulations are used to show the importance of more detailed subject-specific MV geometry with 3D chordal structure to simulate a proper closure validated against [Formula: see text]CT images of the closed valve. Two computational models, before and after use of the aforementioned technique, are used to simulate closure of the MV.

  4. Architecture of an in vivo-tissue engineered autologous conduit "Biovalve".

    PubMed

    Hayashida, Kyoko; Kanda, Keiichi; Oie, Tomonori; Okamoto, Yoshihiro; Ishibashi-Ueda, Hatsue; Onoyama, Masaaki; Tajikawa, Tsutomu; Ohba, Kenkichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2008-07-01

    As a practical concept of regenerative medicine, we have focused on in vivo tissue engineering utilizing the foreign body reaction. Plastic substrates for valvular leaflet organization, consisting of two pieces assembled with a small aperture were inserted into a microporous polyurethane conduit scaffold. The assembly was placed in the subcutaneous spaces of Japanese white rabbits for 1 month. After the substrates were pulled out from the harvested implant, valve leaflet-shaped membranous tissue was formed inside the tubular scaffold as designed. The valve leaflet was composed of the same collagen-rich tissue, with the absence of any elastic fiber, as that which had ingrown or covered the scaffold. No abnormal collection or infiltration of inflammatory cells in the leaflet and the scaffold could be demonstrated. According to the immunohistochemical staining, the leaflet was comprised of numerous vimentin- or alpha-SMA-positive cells, corresponding to fibroblasts or myofibroblats, but contained no desmin-positive cells. The analysis of the video data of the valve movement showed that, in synchronization with the backward flow in the diastolic phase, the valve closed rapidly and tightly and, in the transition phase of the flow direction, the valve opened smoothly without flapping or hitting the scaffold wall. Using mold designs, consisting of two different plastic substrates and the tubular scaffold, in conjunction with "in body tissue architecture," the complex 3-dimensional autologous conduit-typed Biovalve was developed for the first time. 2007 Wiley Periodicals, Inc.

  5. Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.

    PubMed

    Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H

    2016-06-01

    MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.

  6. Hydrothermal Pretreatment of Date Palm (Phoenix dactylifera L.) Leaflets and Rachis to Enhance Enzymatic Digestibility and Bioethanol Potential

    PubMed Central

    Fang, Chuanji; Cybulska, Iwona; Brudecki, Grzegorz P.; Frankær, Christian Grundahl; Thomsen, Mette Hedegaard

    2015-01-01

    Date palm residues are one of the most promising lignocellulosic biomass for bioethanol production in the Middle East. In this study, leaflets and rachis were subjected to hydrothermal pretreatment to overcome the recalcitrance of the biomass for enzymatic conversion. Evident morphological, structural, and chemical changes were observed by scanning electron microscopy, X-ray diffraction, and infrared spectroscopy after pretreatment. High glucan (>90% for both leaflets and rachis) and xylan (>75% for leaflets and >79% for rachis) recovery were achieved. Under the optimal condition of hydrothermal pretreatment (210°C/10 min) highly digestible (glucan convertibility, 100% to leaflets, 78% to rachis) and fermentable (ethanol yield, 96% to leaflets, 80% to rachis) solid fractions were obtained. Fermentability test of the liquid fractions proved that no considerable inhibitors to Saccharomyces cerevisiae were produced in hydrothermal pretreatment. Given the high sugar recovery, enzymatic digestibility, and ethanol yield, production of bioethanol by hydrothermal pretreatment could be a promising way of valorization of date palm residues in this region. PMID:26347878

  7. Advanced CT acquisition protocol with a third-generation dual-source CT scanner and iterative reconstruction technique for comprehensive prosthetic heart valve assessment.

    PubMed

    Faure, Marguerite E; Swart, Laurens E; Dijkshoorn, Marcel L; Bekkers, Jos A; van Straten, Marcel; Nieman, Koen; Parizel, Paul M; Krestin, Gabriel P; Budde, Ricardo P J

    2018-05-01

    Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.

  8. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  9. Efficient replacement of plasma membrane outer leaflet phospholipids and sphingolipids in cells with exogenous lipids

    PubMed Central

    Kim, JiHyun; Huang, Zhen; St. Clair, Johnna R.; Brown, Deborah A.; London, Erwin

    2016-01-01

    Our understanding of membranes and membrane lipid function has lagged far behind that of nucleic acids and proteins, largely because it is difficult to manipulate cellular membrane lipid composition. To help solve this problem, we show that methyl-α-cyclodextrin (MαCD)-catalyzed lipid exchange can be used to maximally replace the sphingolipids and phospholipids in the outer leaflet of the plasma membrane of living mammalian cells with exogenous lipids, including unnatural lipids. In addition, lipid exchange experiments revealed that 70–80% of cell sphingomyelin resided in the plasma membrane outer leaflet; the asymmetry of metabolically active cells was similar to that previously defined for erythrocytes, as judged by outer leaflet lipid composition; and plasma membrane outer leaflet phosphatidylcholine had a significantly lower level of unsaturation than phosphatidylcholine in the remainder of the cell. The data also provided a rough estimate for the total cellular lipids residing in the plasma membrane (about half). In addition to such lipidomics applications, the exchange method should have wide potential for investigations of lipid function and modification of cellular behavior by modification of lipids. PMID:27872310

  10. Efficient replacement of plasma membrane outer leaflet phospholipids and sphingolipids in cells with exogenous lipids.

    PubMed

    Li, Guangtao; Kim, JiHyun; Huang, Zhen; St Clair, Johnna R; Brown, Deborah A; London, Erwin

    2016-12-06

    Our understanding of membranes and membrane lipid function has lagged far behind that of nucleic acids and proteins, largely because it is difficult to manipulate cellular membrane lipid composition. To help solve this problem, we show that methyl-α-cyclodextrin (MαCD)-catalyzed lipid exchange can be used to maximally replace the sphingolipids and phospholipids in the outer leaflet of the plasma membrane of living mammalian cells with exogenous lipids, including unnatural lipids. In addition, lipid exchange experiments revealed that 70-80% of cell sphingomyelin resided in the plasma membrane outer leaflet; the asymmetry of metabolically active cells was similar to that previously defined for erythrocytes, as judged by outer leaflet lipid composition; and plasma membrane outer leaflet phosphatidylcholine had a significantly lower level of unsaturation than phosphatidylcholine in the remainder of the cell. The data also provided a rough estimate for the total cellular lipids residing in the plasma membrane (about half). In addition to such lipidomics applications, the exchange method should have wide potential for investigations of lipid function and modification of cellular behavior by modification of lipids.

  11. Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results.

    PubMed

    Vrandecic, M; Gontijo Filho, B; Fantini, F; Barbosa, J; Martins, I; de Oliveira, O C; Martins, C; Max, R; Drumond, L; Oliveira, C; Ferrufino, A; Alcocer, E; Silva, J A; Vrandecic, E

    1998-03-01

    The study aimed to determine the clinical performance of bovine pericardial aldehyde-treated products alone or in combination with aortic leaflets of porcine origin. These included a composite porcine stentless aortic valve attached to a scalloped pericardial tube (BSAV), and valved and non-valved bovine pericardial conduits for use in left-sided heart lesions (BPG). For BSAV grafts, between January 1990 and August 1996, 163 patients (119 males) had their aortic valves replaced by SJM Biocor BASV. Mean age was 37.9 +/- 17.6 years (range: 1 to 76 years). Rheumatic heart disease sequelae (n = 72) and replacement of a prosthetic heart valve (n = 46) were predominant. Preoperative NYHA functional class showed 90 patients (55.2%) in class III and 50 (30.7%) in class IV. BPVC and NVPC grafts were used in 166 patients: acute aortic dissection was the main indication in 52 (31.3%) and chronic in 36 (21/7%). The ascending aorta was involved in 141 patients (84.9%); grafts were seldom used at other sites. In most patients the graft implanted was either a non-valved (n = 79) or a valved (n = 75) pericardial conduit. Twelve patients had a localized lesion and required a patch repair. For BASV grafts, the non-valve-related hospital mortality rate was 4.9%. There were 14.7% non-fatal complications with full recovery of all patients. Mean follow up in 141 patients was 3.0 +/- 1.4 years (range: 1 month to 7.2 years); 14 patients were lost to follow up. Late, non-conduit-related, mortality occurred in seven patients (4.9%). Eight patients underwent reoperation. The current clinical follow up of 127 patients has shown 118 (92.9%) with competent valves and nine (7.0%) with mild stable aortic insufficiency. For BPVC and NVPC grafts, hospital mortality rate was 16.9%, death being related to poor preoperative clinical condition. Postoperative follow up was accomplished in 125 patients; reoperation was necessary in seven patients. Histology showed good tissue preservation up to five

  12. Is minimally invasive mitral valve repair with artificial chords reproducible and applicable in routine surgery?

    PubMed

    Panos, Aristotelis; Vlad, Sylvio; Milas, Fotios; Myers, Patrick O

    2015-06-01

    Traditional resectional techniques and chordal transfer are difficult to apply in video-assisted mitral valve repair. Using artificial chords appears easier in this setting. The purpose of this study was to review the effectiveness and reproducibility of neochordal repair as a routine approach to minimally invasive mitral repair, and to assess the stability of neochord implantation using the figure-of-eight suture without pledgets in this setting. This is a retrospective review of all patients who underwent minimally invasive video-assisted mitral valve repair from 2008 to 2013. The primary endpoints were recurrent mitral regurgitation and reoperation. A total of 426 consecutive patients were included during the study period, with a mean age of 55 ± 18 years. Neochords were used in all patients, and in association with leaflet resection in 47 patients. One patient was not repairable and underwent valve replacement (repair rate, 99.8%). Fifteen patients had Grade I (3.5%) regurgitation, whereas the remainder had none. Patients were fast-tracked, with 25% extubated in the operation theatre and the remainder within 6 h. There were 5 deaths within 30 days (1.2%). Follow-up ranged 3-60 months, during which all of the patients remained with no or trace mitral regurgitation. No de-insertion or rupture of any neochords was found, and no patients required a reoperation. Minimally invasive mitral valve repair using neochords provided a high rate of repair, reproducible results in a routine cardiac surgery setting and stable repair during follow-up. This has become our preferred technique for mitral valve surgery. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. [Communication prostheses and behavioral alignment in hospital leaflets].

    PubMed

    Vasconcellos-Silva, Paulo Roberto; Rivera, Francisco Javier Uribe; Rozemberg, Brani

    2003-08-01

    Review was made of publications that describe experience with printed material distributed to the lay public in hospital institutions. From the 146 leaflets examined, those aimed at professionals or disabled people, thus leaving 75 papers that illustrate the present pattern for the rationality behind the production, use and evaluation of this type of resource. In a general manner, such leaflets invest in the power of "ideal printed information" to align behavior with the hospital's biomedical agenda. The underlying rationality that permeates them perceives the "perfect information package" as one that efficiently describes its technical content for the purpose of unidirectional persuasion, is up-to-date in relation to readability scales and embellished by graphic design, and emphasizes the priorities defined by the professionals. Such "communication prostheses" should be capable of electronic validation by means of software suitable for proportioning the "doses" to the subject matter. Information as a drug, cognitivism, the lack of research on message reception and the need for communicative action for the deconstruction of systems of closed thinking within the hospital environment have been discussed.

  14. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome.

    PubMed

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-09-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight into the mechanisms of TVI. It is the intent of this report to propose a systematic method on how to evaluate and display 3DE images of the TV in HLHS which has not been done previously. TV anatomy, function, and the known mechanisms of insufficiency are reviewed. We defined three regions of the TV (anterior, posterior, septal) that can help define valve "leaflets" that incorporates the many variations of TV anatomy. To determine how the surgeon views the TV, a picture of a pathologic specimen of the TV was placed on a computer screen and rotated until it was oriented as it appears during surgery, the "surgeons view." We have proposed a systematic method for evaluating and displaying the TV using 3DE which can provide significant insight into the mechanisms causing TVI in HLHS. This has the potential to improve both the surgical approach to repairing the valve and, ultimately, patient outcomes.

  15. A scanning electron microscopy study of the invasion of leaflets of a bloat-safe and a bloat-causing legume by rumen microorganisms.

    PubMed

    Fay, J P; Cheng, K J; Hanna, M R; Howarth, R E; Costerton, J W

    1981-04-01

    A newly developed technique using ruthenium red to detect foci of bacterial digestion in mounts of whole leaflets that had been incubated with rumen bacteria was used to compare the digestion of alfalfa, a bloat-causing legume, and sainfoin, a bloat-safe legume. When whole leaflets were suspended in an artificial rumen medium and inoculated with rumen bacteria, massive bacterial adhesion and proliferation were noted at the stomata of alfalfa leaflets after 6 h of incubation, whereas only a few isolated bacteria adhered near the stomata of sainfoin leaflets After 22 h of incubation, the epidermal layers of alfalfa leaflets had peeled away in many areas, revealing an extensive bacterial invasion of the underlying mesophyll tissue in which large bacterial microcolonies had formed in intercellular spaces, and in intracellular spaces in several areas where plant cell walls had broken down. After 22 h of incubation, the surface of sainfoin leaflets resembled that of alfalfa leaflets at 6 h, with bacterial microcolonies adhering to the area surrounding the stomata, but without sloughing of the epidermis. Uninoculated control leaflets of both species showed no surface alteration but part of their normal bacterial flora had proliferated to form microcolonies on the surface after 22 h incubation. Dry matter loss due to leaching or bacterial digestion when whole leaflets of legumes were suspended in an artificial rumen medium, alone or with rumen bacteria, was significantly higher in the bloat-causing group. Values of leaching and of bacterial digestion were positively correlated. We conclude that reported differences in plant anatomy, and in cell wall chemistry, produce distinct rates or organic nutrient release from legume leaflets, and that these same differences produce an equally distinct susceptibility of leaflets to bacterial invasion, plant cell rupture, and the consequent release of intracellular plant components. The rate of release of organic nutrients from legume

  16. Non-functional tricuspid valve disease

    PubMed Central

    2017-01-01

    Only 75% of severe tricuspid regurgitation is classified as functional, or related primarily to pulmonary hypertension, right ventricular dysfunction, or a combination of both. Non-functional tricuspid regurgitation occurs when there is damage to the tricuspid leaflets, chordae, papillary muscles, or annulus, independent of right ventricular dysfunction or pulmonary hypertension. The entities that cause non-functional tricuspid regurgitation include rheumatic and myxomatous disease, acquired and genetic connective tissue disorders, endocarditis, sarcoid, pacing, RV biopsy, blunt trauma, radiation, carcinoid, ergot alkaloids, dopamine agonists, fenfluramine, cardiac tumors, atrial fibrillation, and congenital malformations. Over time, severe tricuspid regurgitation that is initially non-functional, can blend into functional tricuspid regurgitation, related to progressive right ventricular dysfunction. Symptoms and signs, including a falling right ventricular ejection fraction, cardiac cirrhosis, ascites, esophageal varices, and anasarca, may occur insidiously and late, but are associated with substantial morbidity and mortality. Attempted valve repair or replacement at late stages carries a high mortality. Crucial to following patients with severe non-functional tricuspid regurgitation is attention to echo quantification of the tricuspid regurgitation and right ventricular function, patient symptoms, and the physical examination. PMID:28706863

  17. A neonate with mitral stenosis due to accessory mitral valve, ventricular septal defect, and patent ductus arteriosus: changes in echocardiographical findings during the neonatal period.

    PubMed

    Ito, Tadahiko; Okubo, Tadashi

    2002-12-01

    A female neonate with mitral stenosis due to accessory mitral valve with ventricular septal defect and patent ductus arteriosus is described. She was referred to our hospital because of neonatal asphyxia. Asphyxia was improved by ventilator support, but rapid deterioration of respiration with pulmonary congestion and hemorrhage appeared 8 days after birth. Echocardiography revealed an accessory mitral valve attached to the anterior mitral leaflet with a perimembranous ventricular septal defect and patent ductus arteriosus. Although there were no echocardiographical findings indicating mitral stenosis on admission, the mitral stenosis blood flow patterns were detected by color and pulsed Doppler examination performed on the eighth day after admission. Transaortic resection of accessory mitral valve tissue was performed with patch closure of the ventricular septal defect and ligation of the ductus arteriosus 35 days after birth. After operation, pulmonary congestion and hemorrhage were improved. Postoperative echocardiography showed complete resection of the accessory mitral valve and no mitral insufficiency. We concluded that the combination of the accessory mitral valve and left-to-right shunt due to ventricular septal defect or patent ducturs arteriosus might have led to a critical hemodynamic condition due to relative mitral stenosis in the neonatal period with the decrease in pulmonary vascular resistance.

  18. Endoscopic feature tracking for augmented-reality assisted prosthesis selection in mitral valve repair

    NASA Astrophysics Data System (ADS)

    Engelhardt, Sandy; Kolb, Silvio; De Simone, Raffaele; Karck, Matthias; Meinzer, Hans-Peter; Wolf, Ivo

    2016-03-01

    Mitral valve annuloplasty describes a surgical procedure where an artificial prosthesis is sutured onto the anatomical structure of the mitral annulus to re-establish the valve's functionality. Choosing an appropriate commercially available ring size and shape is a difficult decision the surgeon has to make intraoperatively according to his experience. In our augmented-reality framework, digitalized ring models are superimposed onto endoscopic image streams without using any additional hardware. To place the ring model on the proper position within the endoscopic image plane, a pose estimation is performed that depends on the localization of sutures placed by the surgeon around the leaflet origins and punctured through the stiffer structure of the annulus. In this work, the tissue penetration points are tracked by the real-time capable Lucas Kanade optical flow algorithm. The accuracy and robustness of this tracking algorithm is investigated with respect to the question whether outliers influence the subsequent pose estimation. Our results suggest that optical flow is very stable for a variety of different endoscopic scenes and tracking errors do not affect the position of the superimposed virtual objects in the scene, making this approach a viable candidate for annuloplasty augmented reality-enhanced decision support.

  19. Anatomic, histologic, and two-dimensional-echocardiographic evaluation of mitral valve anatomy in dogs.

    PubMed

    Borgarelli, Michele; Tursi, Massimiliano; La Rosa, Giuseppe; Savarino, Paolo; Galloni, Marco

    2011-09-01

    To compare echocardiographic variables of dogs with postmortem anatomic measurements and histologic characteristics of the mitral valve (MV). 21 cardiologically normal dogs. The MV was measured echocardiographically by use of the right parasternal 5-chamber long-axis view. Dogs were euthanized, and anatomic measurements of the MV annulus (MVa) were performed at the level of the left circumflex coronary artery. Mitral valve leaflets (MVLs) and chordae tendineae were measured. Structure of the MVLs was histologically evaluated in 3 segments (proximal, middle, and distal). Echocardiographic measurements of MVL length did not differ significantly from anatomic measurements. A positive correlation was detected between body weight and MVa area. There was a negative correlation between MVa area and the percentage by which the MVL area exceeded the MVa area. Anterior MVLs had a significantly higher number of chordae tendineae than did posterior MVLs. Histologically, layering of MVLs was less preserved in the distal segment, whereas the muscular component and adipose tissue were significantly more diffuse in the proximal and middle segments. The MV in cardiologically normal dogs had wide anatomic variability. Anatomic measurements of MVL length were correlated with echocardiographic measurements.

  20. Aortic Valve Replacement for Moderate Aortic Stenosis with Severe Calcification and Left Ventricualr Dysfunction-A Case Report and Review of the Literature.

    PubMed

    Narang, Nikhil; Lang, Roberto M; Liarski, Vladimir M; Jeevanandam, Valluvan; Hofmann Bowman, Marion A

    2017-01-01

    A 55-year-old man with a history of erosive, seropositive rheumatoid arthritis (RA), and interstitial lung disease presented with shortness of breath. Echocardiography showed new-onset severe left ventricular (LV) dysfunction with an ejection fraction (EF) of 15% and moderately increased mean aortic valve gradient of 20 mmHg in a trileaflet aortic valve with severe sclero-calcific degeneration. Coronary angiography revealed no significant obstructive coronary disease. Invasive hemodynamic studies and dobutamine stress echocardiography were consistent with moderate aortic stenosis. Guideline directed medical therapy for heart failure with reduced EF was initiated; however, diuretics and neurohormonal blockade (beta-blocker and angiotensin receptor blocker) provided minimal improvement, and the patient remained functionally limited. Of interest, echocardiography performed 1 year prior to his presentation showed normal LV EF and mild aortic leaflet calcification with moderate stenosis, suggesting a rapid progressing of calcific aortic valve disease. Subsequently, the patient underwent surgical aortic valve replacement and demonstrated excellent postsurgical recovery of LV EF (55%). Calcific aortic valve disease is commonly associated with aging, bicuspid aortic valve, and chronic kidney disease. Pathophysiological mechanism for valvular calcification is incompletely understood but include osteogenic transformation of valvular interstitial cells mediated by local and systemic inflammatory processes. Several rheumatologic diseases including RA are associated with premature atherosclerosis and arterial calcification, and we speculated a similar role of RA accelerating calcific aortic valve disease. We present a case of accelerated aortic valve calcification with (only) moderate stenosis, complicated by a rapid decline in LV systolic performance. Guidelines for AVR in moderate stenosis without concomitant cardiac surgery are not well established, although it should be

  1. The effect of vortex formation on left ventricular filling and mitral valve efficiency.

    PubMed

    Pierrakos, Olga; Vlachos, Pavlos P

    2006-08-01

    A new mechanism for quantifying the filling energetics in the left ventricle (LV) and past mechanical heart valves (MHV) is identified and presented. This mechanism is attributed to vortex formation dynamics past MHV leaflets. Recent studies support the conjecture that the natural healthy left ventricle (LV) performs in an optimum, energy-preserving manner by redirecting the flow with high efficiency. Yet to date, no quantitative proof has been presented. The present work provides quantitative results and validation of a theory based on the dynamics of vortex ring formation, which is governed by a critical formation number (FN) that corresponds to the dimensionless time at which the vortex ring has reached its maximum circulation content, in support of this hypothesis. Herein, several parameters (vortex ring circulation, vortex ring energy, critical FN, hydrodynamic efficiencies, vortex ring propagation speed) have been quantified and presented as a means of bridging the physics of vortex formation in the LV. In fact, the diastolic hydrodynamic efficiencies were found to be 60, 41, and 29%, respectively, for the porcine, anti-anatomical, and anatomical valve configurations. This assessment provides quantitative proof of vortex formation, which is dependent of valve design and orientation, being an important flow characteristic and associated to LV energetics. Time resolved digital particle image velocimetry with kilohertz sampling rate was used to study the ejection of fluid into the LV and resolve the spatiotemporal evolution of the flow. The clinical significance of this study is quantifying vortex formation and the critical FN that can potentially serve as a parameter to quantify the LV filling process and the performance of heart valves.

  2. E-learning or educational leaflet: does it make a difference in oral health promotion? A clustered randomized trial.

    PubMed

    Al Bardaweel, Susan; Dashash, Mayssoon

    2018-05-10

    The early recognition of technology together with great ability to use computers and smart systems have promoted researchers to investigate the possibilities of utilizing technology for improving health care in children. The aim of this study was to compare between the traditional educational leaflets and E-applications in improving oral health knowledge, oral hygiene and gingival health in schoolchildren of Damascus city, Syria. A clustered randomized controlled trial at two public primary schools was performed. About 220 schoolchildren aged 10-11 years were included in this study and grouped into two clusters. Children in Leaflet cluster received oral health education through leaflets, while children in E-learning cluster received oral health education through an E-learning program. A questionnaire was designed to register information related to oral health knowledge and to record Plaque and Gingival indices. Questionnaire administration and clinical assessment were undertaken at baseline, 6 and at 12 weeks of oral health education. Data was analysed using one way repeated measures ANOVA, post hoc Bonferroni test and independent samples t-test. Leaflet cluster (107 participants) had statistically significant better oral health knowledge than E-learning cluster (104 participants) at 6 weeks (P < 0.05) and at 12 weeks (P < 0.05) (Leaflet cluster:100 participants, E-learning cluster:100 participants). The mean knowledge gain compared to baseline was higher in Leaflet cluster than in E-learning cluster. A significant reduction in the PI means at 6 weeks and 12 weeks was observed in both clusters (P < 0.05) when compared to baseline. Children in Leaflet cluster had significantly less plaque than those in E-learning cluster at 6 weeks (P < 0.05) and at 12 weeks (P < 0.05). Similarly, a significant reduction in the GI means at 6 weeks and 12 weeks was observed in both clusters when compared to baseline (P < 0.05). Children in Leaflet

  3. Consumer's Perception on Design and Layout of Consumer Medical Information Leaflets on Obesity and Lipid Lowering Drugs.

    PubMed

    Mathew, Elizabeth M; Rajiah, Kingston; Sharma, Krishana Kumar

    2013-12-01

    Printed education materials are often used to augment healthcare professional's verbal information to consumers so it serves as an important component of symptom management. They also enhance the teaching process and can be used by consumers as a home reference. This study was aimed to interpret consumers' perception on Consumer Medical Information Leaflets (CMILs) on obesity and lipid lowering drugs, on design and layout using the standard method such as Baker Able Leaflet Design (BALD). Convenience sampling was done. The study was conducted over a period of 3 years in community pharmacy settings in Tamil Nadu, India. The Consumer Medical Information Leaflets (CMILs) were randomly collected from different community pharmacies. Total of 19 CMILs which are commonly used by the consumers were collected and CMILs were assessed using BALD assessment tool Results: According to BALD assessment (46.28%) leaflets were rated as 'above standard' and (53.72) leaflets were rated as 'standard or poor' in layout and design since their scores were less than 25. This shows that this issue may be important from the patient's perspective, which may discourage patient from actually reading the CMILs. In India, generally CMILs are continued to be prepared in English and with higher proportion of consumers with English illiteracy. CMILs, which are prepared without taking consideration of reading level of consumers and proper layout and design, may not achieve the intended purpose. This is an important aspect that any company has to reckon while preparing leaflets and at least in some major local languages in which CMILs have to be prepared.

  4. Randomised controlled trial using smartphone website vs leaflet to support antenatal perineal massage practice for pregnant women.

    PubMed

    Takeuchi, Shoko; Horiuchi, Shigeko

    2016-10-01

    In Japan, the rate of pregnant women who practice antenatal perineal massage was only 15.1%. The aim of this study was to develop and evaluate a smartphone website and a leaflet to support antenatal perineal massage practice for primiparous women. In a randomised control trial, 161 primiparous women were randomly assigned to a smartphone website group (n=81) or a leaflet group (n=80). Data analysis were by per protocol analysis and intention to treat analysis. Of the 161 women participants, 47 in the smartphone website group and 49 in the leaflet group completed all questionnaires. Primary outcome was continuance rate (three times a week over a three week period) of antenatal perineal massage practice. The rates by a per protocol analysis were 51.1% in the smartphone website group and 51.0% in the leaflet group, respectively. There was no significant difference between the groups. Moreover, the rates by an intention to treat analysis were 29.6% in the smartphone website group and 31.3% in the leaflet group, respectively. There was also no significant difference between the groups. There were no significant differences in the evaluation of perineal massage, childbirth self-efficacy, satisfaction with efforts towards childbirth, and perineal outcomes following childbirth which were measured as secondary outcomes between the groups. There was no significant difference in continuance rate of antenatal perineal massage practice between those using a smartphone website and those with a leaflet, however, the rate was better than no instructions. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    PubMed

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  6. Mitral valve repair in dogs using an ePTFE chordal implantation device: a pilot study.

    PubMed

    Borgarelli, M; Lanz, O; Pavlisko, N; Abbott, J A; Menciotti, G; Aherne, M; Lahmers, S M; Lahmers, K K; Gammie, J S

    2017-06-01

    Mitral valve (MV) regurgitation due to degenerative MV disease is the leading cause of cardiac death in dogs. We carried out preliminary experiments to determine the feasibility and short-term effects of beating-heart MV repair using an expanded polytetrafluorethylene (ePTFE) chordal implantation device (Harpoon TSD-5) in dogs. This study involved six healthy purpose-bred Beagles (weight range 8.9-11.4 kg). Following a mini-thoracotomy performed under general anesthesia, the TSD-5 was used to place 1 or 2 artificial ePTFE cords on the anterior MV leaflet or the posterior MV leaflet via a left-ventricular transapical approach. The procedure was guided and monitored by transesophageal echocardiography. Postoperative antithrombotic treatment consisted of clopidogrel or a combination of clopidogrel and apixaban. Dogs were serially evaluated by transthoracic echocardiography at day 1, 7, 14, 21, and 30. The hearts were then examined for evaluation of tissues reactions and to detect signs of endothelialization. One or two chords were successfully implanted in five dogs. Four dogs completed the 30 days follow-up. One dog died intra-operatively because of aortic perforation. One dog died early post-operatively from a hemorrhagic pleural effusion attributed to overly aggressive antithrombotic treatment. One dog developed a thrombus surrounding both the knot and the synthetic cord. Postmortem exam confirmed secure placement of ePTFE knots in the mitral leaflets in all dogs and the presence of endothelialization of the knots and chords. These preliminary results demonstrate the feasibility of artificial chordal placement using an ePTFE cordal implantation device in dogs. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Reconstruction of the right ventricular outflow tract with a bovine jugular vein graft fixed with a naturally occurring crosslinking agent (genipin) in a canine model.

    PubMed

    Chang, Y; Tsai, C C; Liang, H C; Sung, H W

    2001-12-01

    This study was designed to evaluate a newly developed biologic valved conduit fixed with genipin used to reconstruct the right ventricular outflow tract in a canine model. Fresh bovine jugular veins with a retained native valve procured from a slaughterhouse were used as raw materials to fabricate the valved conduits. A naturally occurring crosslinking agent, genipin, was used to fix the procured jugular veins. The glutaraldehyde-fixed counterpart was used as a control. A canine model was used in the study. Echocardiography revealed that the motion of the valvular leaflets in both the glutaraldehyde- and genipin-fixed conduits was satisfactory. The transvalvular pressure gradients of both studied groups were minimal. No endothelium-like cells were observed on the luminal surface of the conduit and the valvular leaflet for the glutaraldehyde-fixed group throughout the entire course of the study. In contrast, endothelium-like cells were observed on the entire surface of the genipin-fixed valved conduit retrieved at 6 months postoperatively in all the cases studied. There was no evidence of luminal fibrous peel in any the valved conduits studied. Degradation of valvular leaflet in one of the glutaraldehyde-fixed conduits was observed. In this particular case, thrombus formation was also observed on the surface of the valvular leaflet. On the other hand, no apparent degradation or thrombus formation was observed on the surfaces of the genipin-fixed valvular leaflet and conduit. A significantly more severe inflammatory reaction was observed for the glutaraldehyde-fixed conduit than for its genipin-fixed counterpart throughout the entire course of the study. The calcium contents of the samples before implantation and those retrieved at distinct implantation duration were minimal for both the glutaraldehyde- and genipin-fixed tissues. Although further studies are necessary, the genipin-fixed valved conduit appears to have great potential in helping mitigate the

  8. Active tissue stiffness modulation controls valve interstitial cell phenotype and osteogenic potential in 3D culture.

    PubMed

    Duan, Bin; Yin, Ziying; Hockaday Kang, Laura; Magin, Richard L; Butcher, Jonathan T

    2016-05-01

    Calcific aortic valve disease (CAVD) progression is a highly dynamic process whereby normally fibroblastic valve interstitial cells (VIC) undergo osteogenic differentiation, maladaptive extracellular matrix (ECM) composition, structural remodeling, and tissue matrix stiffening. However, how VIC with different phenotypes dynamically affect matrix properties and how the altered matrix further affects VIC phenotypes in response to physiological and pathological conditions have not yet been determined. In this study, we develop 3D hydrogels with tunable matrix stiffness to investigate the dynamic interplay between VIC phenotypes and matrix biomechanics. We find that VIC populated within hydrogels with valve leaflet like stiffness differentiate towards myofibroblasts in osteogenic media, but surprisingly undergo osteogenic differentiation when cultured within lower initial stiffness hydrogels. VIC differentiation progressively stiffens the hydrogel microenvironment, which further upregulates both early and late osteogenic markers. These findings identify a dynamic positive feedback loop that governs acceleration of VIC calcification. Temporal stiffening of pathologically lower stiffness matrix back to normal level, or blocking the mechanosensitive RhoA/ROCK signaling pathway, delays the osteogenic differentiation process. Therefore, direct ECM biomechanical modulation can affect VIC phenotypes towards and against osteogenic differentiation in 3D culture. These findings highlight the importance of the homeostatic maintenance of matrix stiffness to restrict pathological VIC differentiation. We implement 3D hydrogels with tunable matrix stiffness to investigate the dynamic interaction between valve interstitial cells (VIC, major cell population in heart valve) and matrix biomechanics. This work focuses on how human VIC responses to changing 3D culture environments. Our findings identify a dynamic positive feedback loop that governs acceleration of VIC calcification, which

  9. Readability Analysis of the Package Leaflets for Biological Medicines Available on the Internet Between 2007 and 2013: An Analytical Longitudinal Study

    PubMed Central

    2016-01-01

    Background The package leaflet included in the packaging of all medicinal products plays an important role in the transmission of medicine-related information to patients. Therefore, in 2009, the European Commission published readability guidelines to try to ensure that the information contained in the package leaflet is understood by patients. Objective The main objective of this study was to calculate and compare the readability levels and length (number of words) of the package leaflets for biological medicines in 2007, 2010, and 2013. Methods The sample of this study included 36 biological medicine package leaflets that were downloaded from the European Medicines Agency website in three different years: 2007, 2010, and 2013. The readability of the selected package leaflets was obtained using the following readability formulas: SMOG grade, Flesch-Kincaid grade level, and Szigriszt’s perspicuity index. The length (number of words) of the package leaflets was also measured. Afterwards, the relationship between these quantitative variables (three readability indexes and length) and categorical (or qualitative) variables were analyzed. The categorical variables were the year when the package leaflet was downloaded, the package leaflet section, type of medicine, year of authorization of biological medicine, and marketing authorization holder. Results The readability values of all the package leaflets exceeded the sixth-grade reading level, which is the recommended value for health-related written materials. No statistically significant differences were found between the three years of study in the readability indexes, although differences were observed in the case of the length (P=.002), which increased over the study period. When the relationship between readability indexes and length and the other variables was analyzed, statistically significant differences were found between package leaflet sections (P<.001) and between the groups of medicine only with regard

  10. Readability Analysis of the Package Leaflets for Biological Medicines Available on the Internet Between 2007 and 2013: An Analytical Longitudinal Study.

    PubMed

    Piñero-López, María Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2016-05-25

    The package leaflet included in the packaging of all medicinal products plays an important role in the transmission of medicine-related information to patients. Therefore, in 2009, the European Commission published readability guidelines to try to ensure that the information contained in the package leaflet is understood by patients. The main objective of this study was to calculate and compare the readability levels and length (number of words) of the package leaflets for biological medicines in 2007, 2010, and 2013. The sample of this study included 36 biological medicine package leaflets that were downloaded from the European Medicines Agency website in three different years: 2007, 2010, and 2013. The readability of the selected package leaflets was obtained using the following readability formulas: SMOG grade, Flesch-Kincaid grade level, and Szigriszt's perspicuity index. The length (number of words) of the package leaflets was also measured. Afterwards, the relationship between these quantitative variables (three readability indexes and length) and categorical (or qualitative) variables were analyzed. The categorical variables were the year when the package leaflet was downloaded, the package leaflet section, type of medicine, year of authorization of biological medicine, and marketing authorization holder. The readability values of all the package leaflets exceeded the sixth-grade reading level, which is the recommended value for health-related written materials. No statistically significant differences were found between the three years of study in the readability indexes, although differences were observed in the case of the length (P=.002), which increased over the study period. When the relationship between readability indexes and length and the other variables was analyzed, statistically significant differences were found between package leaflet sections (P<.001) and between the groups of medicine only with regard to the length over the three studied

  11. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  12. Home delivery of medication - the role of a patient information leaflet on maximising service uptake.

    PubMed

    Watson, L; Ahmed, N; Mccall, H; Minton, J; Benn, P; Edwards, S; Waters, L

    2014-12-01

    There are currently over 30,000 HIV-positive individuals in London and over 25,000 on anti-retroviral therapy. In 2009/2010, this equated to £170m spent by London's NHS on anti-retroviral drugs. Ways employed to reduce this cost include standardising the drugs patients are on and delivering medication to patients at home. Home delivery (HD) medication is exempt from value-added tax. The savings made from 10 patients using the home delivery service would free up resources to provide anti-retroviral therapy to one further patient. Studies have shown that concerns surrounding potential breaches of confidentiality are a potential barrier to some people using the home delivery service. In order to challenge these concerns, a leaflet was devised highlighting the major benefits to both the patient and the NHS of home delivery and addressing concerns over confidentiality. The leaflet was handed out to patients at the Mortimer Market Centre who were currently on anti-retroviral medication but not on home delivery. They were asked to complete a survey on their views of the service before and after reading the leaflet, whether they had been previously aware of the service and whether their concerns had been addressed. Some 79% felt that the patient information leaflet addressed all of their concerns, and it helped 11% decide whether to consider using home delivery. However, as more patients were opposed to the service after reading the patient information leaflet than those considering it, more work needs to be done to explore patients' concerns and other factors influencing home delivery service uptake. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  13. First report of Sneathia sanguinegens together with Mycoplasma hominis in postpartum prosthetic valve infective endocarditis: a case report.

    PubMed

    Kotaskova, Iva; Nemec, Petr; Vanerkova, Martina; Malisova, Barbora; Tejkalova, Renata; Orban, Marek; Zampachova, Vita; Freiberger, Tomas

    2017-08-14

    The presence of more than one bacterial agent is relatively rare in infective endocarditis, although more common in prosthetic cases. Molecular diagnosis from a removed heart tissue is considered a quick and effective way to diagnose fastidious or intracellular agents. Here we describe the case of postpartum polymicrobial prosthetic valve endocarditis in a young woman. Sneathia sanguinegens and Mycoplasma hominis were simultaneously detected from the heart valve sample using broad range 16S rRNA polymerase chain reaction (PCR) followed by sequencing while culture remained negative. Results were confirmed by independent PCR combined with denaturing gradient gel electrophoresis. Before the final agent identification, the highly non-compliant patient left from the hospital against medical advice on empirical intravenous treatment with aminopenicillins, clavulanate and gentamicin switched to oral amoxycillin and clavulanate. Four months after surgery, no signs of inflammation were present despite new regurgitation and valve leaflet flail was detected. However, after another 5 months the patient died from sepsis and recurrent infective endocarditis of unclarified etiology. Mycoplasma hominis is a rare causative agent of infective endocarditis. To the best of our knowledge, presented case is the first report of Sneathia sanguinegens detected in this condition. Molecular techniques were shown to be useful even in polymicrobial infective endocarditis samples.

  14. Cyclic Mechanical Loading Is Essential for Rac1-Mediated Elongation and Remodeling of the Embryonic Mitral Valve.

    PubMed

    Gould, Russell A; Yalcin, Huseyin C; MacKay, Joanna L; Sauls, Kimberly; Norris, Russell; Kumar, Sanjay; Butcher, Jonathan T

    2016-01-11

    During valvulogenesis, globular endocardial cushions elongate and remodel into highly organized thin fibrous leaflets. Proper regulation of this dynamic process is essential to maintain unidirectional blood flow as the embryonic heart matures. In this study, we tested how mechanosensitive small GTPases, RhoA and Rac1, coordinate atrioventricular valve (AV) differentiation and morphogenesis. RhoA activity and its regulated GTPase-activating protein FilGAP are elevated during early cushion formation but decreased considerably during valve remodeling. In contrast, Rac1 activity was nearly absent in the early cushions but increased substantially as the valve matured. Using gain- and loss-of-function assays, we determined that the RhoA pathway was essential for the contractile myofibroblastic phenotype present in early cushion formation but was surprisingly insufficient to drive matrix compaction during valve maturation. The Rac1 pathway was necessary to induce matrix compaction in vitro through increased cell adhesion, elongation, and stress fiber alignment. Facilitating this process, we found that acute cyclic stretch was a potent activator of RhoA and subsequently downregulated Rac1 activity via FilGAP. On the other hand, chronic cyclic stretch reduced active RhoA and downstream FilGAP, which enabled Rac1 activation. Finally, we used partial atrial ligation experiments to confirm in vivo that altered cyclic mechanical loading augmented or restricted cushion elongation and thinning, directly through potentiation of active Rac1 and active RhoA, respectively. Together, these results demonstrate that cyclic mechanical signaling coordinates the RhoA to Rac1 signaling transition essential for proper embryonic mitral valve remodeling. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. CFD- and Bernoulli-based pressure drop estimates: A comparison using patient anatomies from heart and aortic valve segmentation of CT images.

    PubMed

    Weese, Jürgen; Lungu, Angela; Peters, Jochen; Weber, Frank M; Waechter-Stehle, Irina; Hose, D Rodney

    2017-06-01

    An aortic valve stenosis is an abnormal narrowing of the aortic valve (AV). It impedes blood flow and is often quantified by the geometric orifice area of the AV (AVA) and the pressure drop (PD). Using the Bernoulli equation, a relation between the PD and the effective orifice area (EOA) represented by the area of the vena contracta (VC) downstream of the AV can be derived. We investigate the relation between the AVA and the EOA using patient anatomies derived from cardiac computed tomography (CT) angiography images and computational fluid dynamic (CFD) simulations. We developed a shape-constrained deformable model for segmenting the AV, the ascending aorta (AA), and the left ventricle (LV) in cardiac CT images. In particular, we designed a structured AV mesh model, trained the model on CT scans, and integrated it with an available model for heart segmentation. The planimetric AVA was determined from the cross-sectional slice with minimum AV opening area. In addition, the AVA was determined as the nonobstructed area along the AV axis by projecting the AV leaflet rims on a plane perpendicular to the AV axis. The flow rate was derived from the LV volume change. Steady-state CFD simulations were performed on the patient anatomies resulting from segmentation. Heart and valve segmentation was used to retrospectively analyze 22 cardiac CT angiography image sequences of patients with noncalcified and (partially) severely calcified tricuspid AVs. Resulting AVAs were in the range of 1-4.5 cm 2 and ejection fractions (EFs) between 20 and 75%. AVA values computed by projection were smaller than those computed by planimetry, and both were strongly correlated (R 2 = 0.995). EOA values computed via the Bernoulli equation from CFD-based PD results were strongly correlated with both AVA values (R 2 = 0.97). EOA values were ∼10% smaller than planimetric AVA values. For EOA values < 2.0 cm 2 , the EOA was up to ∼15% larger than the projected AVA. The presented segmentation

  16. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    PubMed

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  17. In vitro investigation of a novel elastic vascular prosthesis for valve-sparing aortic root and ascending aorta replacement.

    PubMed

    Scharfschwerdt, Michael; Leonhard, Moritz; Lehmann, Judith; Richardt, Doreen; Goldmann, Helmut; Sievers, Hans-Hinrich

    2016-05-01

    Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular prosthesis providing elastic behaviours. In a first series (n = 14), haemodynamics and leaflet motions of the aortic valve were investigated and also cyclic changes of aortic dimensions at different levels of the root. In a second series (n = 7), intravascular pressure and dimensions of the proximal descending aorta were measured and the corresponding wall tension was calculated. Haemodynamics of the aortic valve remain comparable after replacement. Though the novel prosthesis does not feature such high distensibility as the native aorta, the dynamic of the root was significantly increased compared with common Dacron prostheses at the commissural level, preserving 'windkessel' function. Thus, wall tension of the residual aorta remained unchanged; nevertheless, maximum pressure-time differential dp/dt increased by 13%. The use of the novel elastic prosthesis for replacement of the ascending aorta seems to be beneficial, especially with regard to the preservation of the aortic windkessel. Further studies will be needed to clarify long-term utilization of the material in vivo. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Long-term results of heart valve replacement with the Edwards Duromedics bileaflet prosthesis: a prospective ten-year clinical follow-up.

    PubMed

    Podesser, B K; Khuenl-Brady, G; Eigenbauer, E; Roedler, S; Schmiedberger, A; Wolner, E; Moritz, A

    1998-05-01

    The Edwards Duromedics valve (Baxter Healthcare Corp., Edwards Division, Santa Ana, Calif.) was designed with a self-irrigating hinge mechanism to reduce thromboembolic complications. After good initial clinical results, distribution was suspended in 1988 after reports of valve fracture after 20,000 valves had been implanted. The manufacturer conducted extensive studies to improve the Edwards Duromedics and reintroduced a modified version, which is available as Edwards Tekna. The purpose of the study was the evaluation of long-term results of the original Edwards Duromedics that might be important for the current version, the Edwards Tekna valve. A prospective clinical 10-year follow-up was performed of 508 patients who underwent valve replacement with the Edwards Duromedics valve in the aortic (n = 268), mitral (n = 183), and aortic and mitral (n = 56) position. The perioperative mortality rate was 6.9%; follow-up was 98% complete, comprising 3648 patient-years for a mean follow-up of 86 months (range: 33 to 144 months). The actuarial freedom from complications at the 10-year follow-up and the incidence rate (percent per patient-year) were as follows: late mortality rate, 69.2% +/- 2.4% (3.5% per patient-year); thromboembolism, 90.7% +/- 1.6% (0.96% per patient-year); anticoagulation-related hemorrhage, 87.7% +/- 1.7% (1.34% per patient-year); prosthetic valve endocarditis, 96.7% +/- 0.09% (0.38% per patient-year); valve-related mortality rate, 89.3% +/- 1.6% (1.21% per patient-year); valve failure, 86.2% +/- 1.85% (1.54% per patient-year); and valve-related morbidity and mortality rate, 71.1% +/- 2.3% (3.2% per patient-year). Three leaflet escapes were observed (one lethal, two successful reoperations; 99.1% +/- 0.05% freedom, 0.08% per patient-year). All patients functionally improved (86% in New York Heart Association classes I and II), and incidence of anemia was insignificant. These results confirm that the Edwards Duromedics valve shows excellent performance

  19. Early beneficial effect of preservation of papillo-annular continuity in mitral valve replacement on left ventricular function.

    PubMed

    Dilip, D; Chandra, A; Rajashekhar, D; Padmanabhan, M

    2001-05-01

    Impairment of left ventricular (LV) function after mitral valve replacement (MVR) has been the most important factor to determine morbidity and mortality. With this in mind, LV performance in the postoperative period was assessed with and without preservation of papillo-annular continuity in MVR. Between March 1994 and August 1998, a total of 383 valve prostheses (202 MVR, 65 AVR, 58 MVR+AVR) were implanted in 325 patients, 177 of whom underwent MVR with Starr Edwards ball cage prostheses (the study group). Of these 177 patients, 105 had MVR with preservation of the posterior mitral leaflet (group I), and 72 had conventional MVR (group II). Predominant lesions were mitral stenosis in 81, mitral regurgitation in 42, and mixed mitral lesion (MS/MR) in 54. Concomitant tricuspid valve annuloplasty was performed in 13, and atrial septal defect repair in five. Sixteen patients underwent MVR for mitral restenosis. In-vivo performance of the prostheses and LV function was evaluated by M-mode and Doppler echocardiography. At 3-6 months clinical improvement was seen in NYHA class, with reduction in cardiothoracic ratio among patients with preserved papillo-annular continuity, irrespective of lesion type. Significant reductions (p <0.05) were seen in left atrial dimensions (54.10 +/- 8.79 preop. versus 44.64 +/- 8.54 postop.; p <0.05), left ventricular end-diastolic dimensions (LVEDD) (50.84 +/- 10.42 preop. versus 41.21 +/- 7.16 postop.; p <0.05) and end-systolic dimensions (LVESD) (34.76 +/- 7.94 preop. versus 28.81 +/- 5.79 postop.; p <0.05) in patients who had their posterior mitral leaflet preserved with significant improvement in ejection fraction (60.31 +/- 8.22 versus 64.47 +/- 7.93; p <0.05). Further analysis of data in group I patients showed significant reductions in left atrial dimensions, LVESD and peak gradient, along with improved ejection fraction compared with conventional (group II) patients. Deterioration in LV function in patients undergoing conventional

  20. Assessment of transmitral flow after mitral valve edge-to-edge repair using High-speed particle image velocimetry

    NASA Astrophysics Data System (ADS)

    Jeyhani, Morteza; Shahriari, Shahrokh; Labrosse, Michel; Kadem, Lyes

    2013-11-01

    Approximately 500,000 people in North America suffer from mitral valve regurgitation (MR). MR is a disorder of the heart in which the mitral valve (MV) leaflets do not close securely during systole. Edge-to-edge repair (EtER) technique can be used to surgically treat MR. This technique produces a double-orifice configuration for the MV. Under these un-physiological conditions, flow downstream of the MV forms a double jet structure that may disturb the intraventricular hemodynamics. Abnormal flow patterns following EtER are mainly characterized by high-shear stress and stagnation zones in the left ventricle (LV), which increase the potential of blood component damage. In this study, a custom-made prosthetic bicuspid MV was used to analyze the LV flow patterns after EtER by means of digital particle image velocimetry (PIV). Although the repair of a MV using EtER technique is an effective approach, this study confirms that EtER leads to changes in the LV flow field, including the generation of a double mitral jet flow and high shear stress regions.