[Longterm results of mitral valve replacement (author's transl)].
Erhard, W; Reichmann, M; Delius, W; Sebening, H; Herrmann, G
1977-04-22
210 patients were followed up by the actuary method for over 5 years after isolated mitral valve replacement or a double valve replacement. After isolated valve replacement the one month survival including the operative mortality was 92+/-2%. The survival after one year was 83+/-3% and after 5 years 66+/-7%. The five year survival of patients in preoperative class III (according to the NYHA) was 73+/-8% and of class IV 57+/-8% (P less than or equal to 0.1). A comparison of valve replacements for pure mitral stenosis or mitral insufficiency showed no statistically significant differences. In the 37 patients who had a double valve replacement the survival risk was not increased in comparison with those patients who had had a single valve replacement. Age above 45 years and a preoperative markedly raised pulmonary arteriolar resistance reduced the chances of survival.
Manouguian, S; Abu-Aishah, N; Neitzel, J
1979-09-01
The experimental results of patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement are reported. The operative technique of this new surgical method is described and the indications are discussed.
Yan, Xiaojuan; Yang, Feng; Zhou, Hanyun; Zhang, Hongshen; Liu, Jianfei; Ma, Kezhong; Li, Yi; Zhu, Jun; Ding, Jianqiang
2015-01-01
Background VKORC1 is reported to be capable of treating several diseases with thrombotic risk, such as cardiac valve replacement. Some single-nucleotide polymorphisms (SNPs) in VKORC1 are documented to be associated with clinical differences in warfarin maintenance dose. This study explored the correlations of VKORC1–1639 G/A, 1173 C/T and 497 T/G genetic polymorphisms with warfarin maintenance dose requirement in patients undergoing cardiac valve replacement. Material/Methods A total of 298 patients undergoing cardiac valve replacement were recruited. During follow-up, clinical data were recorded. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method was applied to detect VKORC1–1639 G/A, 1173 C/T and 497 T/G polymorphisms, and genotypes were analyzed. Results Correlations between warfarin maintenance dose and baseline characteristics revealed statistical significances of age, gender and operation methods with warfarin maintenance dose (all P<0.05). Warfarin maintenance dose in VKORC1–1639 G/A AG + GG carriers was obviously higher than in AA carriers (P<0.001). As compared with patients with TT genotype in VKORC1 1173 C/T, warfarin maintenance dose was apparently higher in patients with CT genotype (P<0.001). Linear regression analysis revealed that gender, operation method, method for heart valve replacement, as well as VKORC1–1639 G/A and 1173 C/T gene polymorphisms were significantly related to warfarin maintenance dose (all P<0.05). Conclusions VKORC1 gene polymorphisms are key genetic factors to affect individual differences in warfarin maintenance dose in patients undergoing cardiac valve replacement; meanwhile, gender, operation method and method for heart valve replacement might also be correlate with warfarin maintenance dose. PMID:26583785
Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.
Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V
1992-02-01
From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.
MOLNAR, ADRIAN; MURESAN, IOAN; TRIFAN, CATALIN; POP, DANA; SACUI, DIANA
2015-01-01
Background and aims The introduction of Duke’s criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. Methods We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. Results The patients’ age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases – 21%), Staphylococcus Spp. (15 cases – 15%), and Enterococcus Spp. (9 cases – 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases – 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases – 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases – 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve – mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was positive. In 3 cases it matched the germ identified in the hemocultures, and in 2 cases it evidenced another bacterium. Conclusion The overall mortality of 5% is well between the limits presented in literature, being higher (30%) in patients who required emergency surgery. For the patients who return into our clinic with prosthetic valve endocarditis, the mortality after surgery was even higher (50%). PMID:26609267
Triple valve surgery: a 25-year experience.
Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen
2004-09-01
Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become encouraging with improvements in surgical techniques and myocardial preservation methods.
Evaluation of mitral valve replacement anchoring in a phantom
NASA Astrophysics Data System (ADS)
McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.
2012-02-01
Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.
2012-01-01
Background Functional tricuspid regurgitation (TR) occurs in patients with rheumatic mitral valve disease even after mitral valve surgery. The aim of this study was to analyze surgical results of TR after previous successful mitral valve surgery. Methods From September 1996 to September 2008, 45 patients with TR after previous mitral valve replacement underwent second operation for TR. In those, 43 patients (95.6%) had right heart failure symptoms (edema of lower extremities, ascites, hepatic congestion, etc.) and 40 patients (88.9%) had atrial fibrillation. Twenty-six patients (57.8%) were in New York Heart Association (NYHA) functional class III, and 19 (42.2%) in class IV. Previous operations included: 41 for mechanical mitral valve replacement (91.1%), 4 for bioprosthetic mitral valve replacement (8.9%), and 7 for tricuspid annuloplasty (15.6%). Results The tricuspid valves were repaired with Kay's (7 cases, 15.6%) or De Vega technique (4 cases, 8.9%). Tricuspid valve replacement was performed in 34 cases (75.6%). One patient (2.2%) died. Postoperative low cardiac output (LCO) occurred in 5 patients and treated successfully. Postoperative echocardiography showed obvious reduction of right atrium and ventricle. The anterioposterior diameter of the right ventricle decreased to 25.5 ± 7.1 mm from 33.7 ± 6.2 mm preoperatively (P < 0. 05). Conclusion TR after mitral valve replacement in rheumatic heart disease is a serious clinical problem. If it occurs or progresses late after mitral valve surgery, tricuspid valve annuloplasty or replacement may be performed with satisfactory results. Due to the serious consequence of untreated TR, aggressive treatment of existing TR during mitral valve surgery is recommended. PMID:22490269
Molnar, Adrian; Muresan, Ioan; Trifan, Catalin; Pop, Dana; Sacui, Diana
2015-01-01
The introduction of Duke's criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. The patients' age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases - 21%), Staphylococcus Spp. (15 cases - 15%), and Enterococcus Spp. (9 cases - 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases - 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases - 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases - 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve - mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was positive. In 3 cases it matched the germ identified in the hemocultures, and in 2 cases it evidenced another bacterium. The overall mortality of 5% is well between the limits presented in literature, being higher (30%) in patients who required emergency surgery. For the patients who return into our clinic with prosthetic valve endocarditis, the mortality after surgery was even higher (50%).
Indication for percutaneous aortic valve implantation
Akin, Ibrahim; Kische, Stephan; Rehders, Tim C.; Nienaber, Christoph A.; Rauchhaus, Mathias; Schneider, Henrik; Liebold, Andreas
2010-01-01
The incidence of valvular aortic stenosis has increased over the past decades due to improved life expectancy. Surgical aortic valve replacement is currently the only treatment option for severe symptomatic aortic stenosis that has been shown to improve survival. However, up to one third of patients who require lifesaving surgical aortic valve replacement are denied surgery due to high comorbidities resulting in a higher operative mortality rate. In the past such patients could only be treated with medical therapy or percutaneous aortic valvuloplasty, neither of which has been shown to improve mortality. With advances in interventional cardiology, transcatheter methods have been developed for aortic valve replacement with the goal of offering a therapeutic solution for patients who are unfit for surgical therapy. Currently there are two catheter-based treatment systems in clinical application (the Edwards SAPIEN aortic valve and the CoreValve ReValving System), utilizing either a balloon-expandable or a self-expanding stent platform, respectively. PMID:22371763
Mechanical valve replacement in congenital heart disease.
Fiane, A E; Lindberg, H L; Saatvedt, K; Svennevig, J L
1996-05-01
Mechanical valves are the prosthesis of choice in valve replacement in children. However, the problem of somatic growth leading to patient-valve mismatch remains present, and the appropriate anticoagulation regimen remains controversial. We present our experience of valve replacement in a young population over 20 years. Between 1972 and 1992, 48 patients (34 males and 14 females), mean age 11.2 years (range 0.4-27.4 years), underwent mechanical valve replacement at our institution. Aortic valve replacement was performed in 28 patients (58.3%), mitral valve replacement in 13 (27.1%), tricuspid valve replacement in six (12.5%) and pulmonary valve replacement in one patient (2.1%). The prostheses used were: St. Jude Medical (n = 2), Björk-Shiley (n = 14), Medtronic Hall (n = 16), Duromedics (n = 2) and CarboMedics (n = 14). Early mortality was 14.3%, 10.7% for aortic valve replacement and 30.8% for mitral valve replacement. Mean follow up for all patients was 8.3 years (range 0-22 years), with a total of 398 patient-years. Seven patients died during the follow up (17.1%). Survival after 10 years, including operative mortality, was 81% for aortic valve replacement, 33% for mitral valve replacement, 83% for tricuspid valve replacement and 100% for pulmonary valve replacement. All patients were anticoagulated with warfarin. In eight patients (16.7%) an antiplatelet drug (aspirin or dipyridamole) was added. Major events included paravalvular leak in six patients (1.5%/pty), valve thrombosis in five (mitral position in two, tricuspid in three) (1.3%/pty) and endocarditis in one patient (0.3%/pty). Minor thromboembolic events occurred in three patients (0.8%/pty) and minor hemorrhagic events in three (0.8%/pty). No patients developed hemolytic anemia and there was no case of structural failure. In our experience, mechanical prostheses in congenital heart disease were associated with significant morbidity and mortality, however long term survival after aortic valve replacement was good (81% at 10 years). Thromboembolic and hemorrhagic events were of minor significance. Atrio-ventricular valve replacement carried the highest risk of valve thrombosis and we now give warfarin and an antiplatelet drug to children undergoing mechanical valve implantation in this position.
Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry
2015-12-01
We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (P< .001) and peripheral vascular complications occurred in 0% of surgicalaortic valve replacement vs 0% of sutureless vs 9.8% transcatheter aortic valve replacement (P< .001). At 24-month follow-up, overall survival (surgical aortic valve replacement = 91.3% ± 2.4% vs sutureless = 94.9% ± 2.1% vs transcatheter aortic valve replacement = 79.5% ± 4.3%; P < .001) and survival free from the composite end point of major adverse cardiovascular events and periprosthetic regurgitation were significantly better in patients undergoing surgical aortic valve replacement and sutureless valve implantation than in patients undergoing transcatheter aortic valve replacement (surgical aortic valve replacement = 92.6% ± 2.3% vs sutureless = 96% ± 1.8% vs transcatheter aortic valve replacement = 77.1% ± 4.2%; P < .001). Multivariate Cox regression analysis identified transcatheter aortic valve replacement as an independent risk factor for overall mortality hazard ratio (hazard ratio, 2.5; confidence interval, 1.1-4.2; P = .018). The use of transcatheter aortic valve replacement in patients with an intermediate- to high-risk profile was associated with a significantly higher incidence of perioperative complications and decreased survival at short- and mid-term when compared with conventional surgery and sutureless valve implantation. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Optimal Elastomeric Scaffold Leaflet Shape for Pulmonary Heart Valve Leaflet Replacement
Fan, Rong; Bayoumi, Ahmed S.; Chen, Peter; Hobson, Christopher M.; Wagner, William R.; Mayer, John E.; Sacks, Michael S.
2012-01-01
Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery. PMID:23294966
Jung, Joonho; Lee, Cheol Joo; Lim, Sang-Hyun; Choi, Ho; Park, Soo-Jin
2013-01-01
A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39℃) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method. PMID:23772409
Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome
Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar
2013-01-01
Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Methods: Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Results: Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Conclusion: Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population. PMID:24404348
Yamaki, F; Nakano, K; Endo, M; Hashimoto, A; Koyanagi, H
1994-02-01
Although a high incidence of strut fracture of the Björk-Shiley convexo-concave (C-C) valve prosthesis has been reported, it is still controversial whether the prosthesis functioning normally should be replaced electively. To clarify our policy for this issue, we reviewed 28 patients who had undergone mitral valve replacement with a C-C valve prosthesis, and evaluated long-term results according to STS guidelines. The incidence of valve-related complications expressed as % patient-year were; structural deterioration 0.30, nonstructural dysfunction 0.30, thromboembolism 1.20. There were no thrombosed valves, anticoagulant-related hemorrhage or prosthetic valve endocarditis. The actuarial free rate after valve replacement with the C-C at 10 years, constructed by the Kaplan-Meier method, were compared with those with St. Jude Medical (SJM) valve prosthesis. (1) Actuarial survival: 77.9 vs 87.3 (NS), (2) Reoperation-free: 91.6 vs 98.0 (p < 0.05), (3) thromboembolism-free: 83.7 vs 83.9 (NS), (4) Event-free (hospital death+reoperation+valve-related complications: 71.2 vs 77.7 (NS). The long-term results with the C-C were compatible to those with a SJM valve prosthesis. However, if a strut fracture occurs, it is very difficult to save the patient's life. The hospital mortality of re-replacement of valve prosthesis during the last 10 years, at our institute, was 2.6%, which is almost equal to the cumulative risk of strut fracture of the C-C valve after 10 years (3.0%).(ABSTRACT TRUNCATED AT 250 WORDS)
2010-01-01
Background This study was undertaken to compare mitral valve repair and replacement as treatments for ischemic mitral regurgitation (IMR) with left ventricular dysfunction (LVD). Specifically, we sought to determine whether the choice of mitral valve procedure affected survival, and discover which patients were predicted to benefit from mitral valve repair and which from replacement. Methods A total of 218 consecutive patients underwent either mitral valve repair (MVP, n = 112) or mitral valve replacement (MVR, n = 106). We retrospectively reviewed the clinical material, operation methods, echocardiography check during operation and follow-up. Patients details and follow-up outcomes were compared using multivariate and Kaplan-Meier analyses. Results No statistical difference was found between the two groups in term of intraoperative data. Early mortality was 3.2% (MVP 2.7% and MVR 3.8%). At discharge, Left ventricular end-systolic and end-diastolic diameter and left ventricular ejection fraction (LVEF) were improved more in the MVP group than MVR group (P < 0.05), however, in follow-up no statistically significant difference was observed between the MVR and MVP group (P > 0.05). Follow-up mitral regurgitation grade was significantly improved in the MVR group compared with the MVP group (P < 0.05). The Kaplan-Meier survival estimates at 1, 3, and 5 years were simlar between MVP and MVR group. Logistic regression revealed poor survival was associated with old age(#75), preoperative renal insufficiency and low left ventricular ejection fraction (< 30%). Conclusion Mitral valve repair is the procedure of choice in the majority of patients having surgery for severe ischemic mitral regurgitation with left ventricular dysfunction. Early results of MVP treatment seem to be satisfactory, but several lines of data indicate that mitral valve repair provided less long-term benefit than mitral valve replacement in the LVD patients. PMID:21059216
Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.
Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F
1983-09-01
Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.
Farag, Mina; Arif, Rawa; Sabashnikov, Anton; Zeriouh, Mohamed; Popov, Aron-Frederik; Ruhparwar, Arjang; Schmack, Bastian; Dohmen, Pascal M.; Szabó, Gábor; Karck, Matthias; Weymann, Alexander
2017-01-01
Background Long-term follow-up data concerning isolated tricuspid valve pathology after replacement or reconstruction is limited. Current American Heart Association guidelines equally recommend repair and replacement when surgical intervention is indicated. Our aim was to investigate and compare operative mortality and long-term survival in patients undergoing isolated tricuspid valve repair surgery versus replacement. Material/Methods Between 1995 and 2011, 109 consecutive patients underwent surgical correction of tricuspid valve pathology at our institution for varying structural pathologies. A total of 41 (37.6%) patients underwent tricuspid annuloplasty/repair (TAP) with or without ring implantation, while 68 (62.3%) patients received tricuspid valve replacement (TVR) of whom 36 (53%) were mechanical and 32 (47%) were biological prostheses. Results Early survival at 30 days after surgery was 97.6% in the TAP group and 91.1% in the TVR group. After 6 months, 89.1% in the TAP group and 87.8% in the TVR group were alive. In terms of long-term survival, there was no further mortality observed after one year post surgery in both groups (Log Rank p=0.919, Breslow p=0.834, Tarone-Ware p=0.880) in the Kaplan-Meier Survival analysis. The 1-, 5-, and 8-year survival rates were 85.8% for TAP and 87.8% for TVR group. Conclusions Surgical repair of the tricuspid valve does not show survival benefit when compared to replacement. Hence valve replacement should be considered generously in patients with reasonable suspicion that regurgitation after repair will reoccur. PMID:28236633
Akpinar, B; Sanisoğlu, I; Konuralp, C; Akay, H; Güden, M; Sönmez, B
1999-01-01
Over the years, many surgical methods have evolved for the treatment of ascending aortic aneurysm in combination with aortic valve regurgitation; however, precise guidelines for optimal surgical techniques for varying presentations have not been defined. We describe the use of a stentless porcine bioprosthesis (Medtronic Freestyle) in a patient with an ascending aortic aneurysm and aortic regurgitation. We used the complete root replacement method, and anastomosed a Dacron graft (Hemashield) between the bioprosthetic valve and the native aorta to replace the distal part of the aneurysm. Images PMID:10524742
CardiaMed mechanical valve: mid-term results of a multicenter clinical trial.
Nazarov, Vladimir M; Zheleznev, Sergey I; Bogachev-Prokophiev, Alexandr V; Afanasyev, Alexandr V; Nemchenko, Eugene V; Jeltovskiy, Yuri V; Lavinyukov, Sergey O
2014-01-01
Prosthesis choice is a major concern in valvular surgery. A multicenter clinical trial was performed to assess the efficacy and safety of the CardiaMed prosthetic heart valve. The study enrolled 420 patients who underwent mitral (209) or aortic (211) valve replacement from 2003 to 2004 at 7 institutions in Russia, and who were followed up from 2006 to 2011. The mean age was 52.2 ± 10.2 years (range, 12-78 years), 47.4% were female, and 99.05% completed the study. The maximum observation term was 7.5 years (2188.5 patient-years); 1081.6 patient-years for aortic and 1106.9 patient-years for mitral valve replacement. The overall 7-year survival rate was 85.1% ± 3.7%; 86.1% ± 4.8% and 84.4% ± 5.4% for aortic and mitral valve replacement, respectively. The 7-year freedom from valve-related death was 93.9% ± 3.7% and 94.5% ± 3.2% for aortic and mitral valve replacement, respectively. When early mortality (<30 days) was excluded, these rates were 94.8% ± 3.1% and 93.8% ± 3.82%, respectively. Linearized valve-dependent complication rates were determined for structural valve failure (0%/patient-year overall), thrombosis (0.63%/patient-year, all for mitral valve replacement), thromboembolic complications including transient neurologic deficits (0.13%/patient-year overall, 0.5%/patient-year for aortic valve replacement, 0.8%/patient-year for mitral valve replacement), hemorrhagic bleeding (0.64%/patient-year overall, 0.55%/patient-year for aortic valve replacement, 0.09%/patient-year for mitral valve replacement), prosthetic endocarditis (0.28%/patient-year overall, 0.28%/patient-year for aortic valve replacement, 0%/patient-year for mitral valve replacement), and hemolysis (0%/patient-year overall). The CardiaMed mechanical heart valve prostheses meets world standards of safety and efficacy.
Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi
2006-01-01
Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.
Ross operation in children: late results.
Elkins, R C; Lane, M M; McCue, C
2001-11-01
Although the Ross operation has become the accepted aortic valve replacement in children, the long-term fate of the pulmonary autograft valve remains unknown. To assess mid-term and late results of autograft valve durability, patient survival and valve-related morbidity, a retrospective review of patients (age range: 3 days to 17 years) having a Ross operation between November 1986 and May 2001 were reviewed. Medical records and patient contacts with all but two of 167 current survivors of 178 consecutive patients having an aortic valve replacement as a Ross operation have been completed during the past two years. The most recent echocardiographic evaluation was reviewed for autograft valve and homograft valve function. Operative mortality was 4.5% (8/178), with three late deaths (two were non-valve-related) for an actuarial survival of 92+/-3% at 12 years. Actuarial freedom from autograft valve degeneration (reoperation or severe insufficiency of autograft valve or valve-related death) was 90+/-4% at 12 years. Autograft valve degeneration was not affected by technique of insertion (141 root replacement, 37 intra-aortic), aortic valve morphology (157 bicuspid or unicuspid, 26 tricuspid), or age at operation. Autograft valve degeneration was worse in patients with a primary lesion of aortic insufficiency than in those with aortic stenosis (p = 0.03). Autograft valve reoperation was required in 12 patients, with autograft valve replacement in seven. Actuarial freedom from autograft replacement was 93+/-3% at 12 years. Homograft valve replacement was required in seven patients, with actuarial freedom from replacement of 90+/-4% at 12 years. Eight additional patients have homograft valve obstruction (gradient > or =50 mmHg), and seven have severe pulmonary insufficiency. Survival and freedom from aortic valve replacement are excellent in children. Homograft valve late function remains a concern, and efforts to improve homograft durability should be encouraged.
Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.
2017-01-01
Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998
2012-01-01
Background Tricuspid regurgitation (TR) is common in patients with mitral valve disease; however, there are no straightforward, rapidly determinably criteria available for deciding whether TR repair should be performed during mitral valve replacement. The aim of our retrospective study was to identify a simple and fast criterion for determining whether TR repair should be performed in patients undergoing mitral valve replacement. Methods We reviewed the records of patients who underwent mitral valve replacement with or without (control) TR repair (DeVega or Kay procedure) from January 2005 to December 2008. Preoperative and 2-year postoperative echocardiographic measurements included right ventricular and atrial diameter, interventricular septum size, TR severity, ejection fraction, and pulmonary artery pressure. Results A total of 89 patients were included (control, n = 50; DeVega, n = 27; Kay, n = 12). Demographic and clinical characteristics were similar between groups. Cardiac variables were similar between the DeVega and Kay groups. Right atrium and ventricular diameter and ejection fraction were significantly decreased postoperatively both in the control and operation (DeVega + Kay) group (P < 0.05). Pulmonary artery pressure was significantly decreased postoperatively in-operation groups (P < 0.05). Our findings indicate that surgical intervention for TR should be considered during mitral valve replacement if any of the following preoperative criteria are met: right atrial transverse diameter > 57 mm; right ventricular end-diastolic diameter > 55 mm; pulmonary artery pressure > 58 mmHg. Conclusions Our findings suggest echocardiography may be used as a rapid and simple means of determining which patients require TR repair during mitral valve replacement. PMID:22443513
Intraoperative echocardiographic detection of regurgitant jets after valve replacement
NASA Technical Reports Server (NTRS)
Morehead, A. J.; Firstenberg, M. S.; Shiota, T.; Qin, J.; Armstrong, G.; Cosgrove, D. M. 3rd; Thomas, J. D.
2000-01-01
BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.
Cicekcioglu, Ferit; Ozen, Anil; Tuluce, Hicran; Tutun, Ufuk; Parlar, Ali Ihsan; Kervan, Umit; Karakas, Sirel; Katircioglu, Salih Fehmi
2008-01-01
Although neurologic outcome after cardiac surgery is well-established, neurocognitive functions after beating heart mitral valve replacement still needs to be elucidated. The aim of this study was to compare preoperative and postoperative neurocognitive functions in patients who underwent beating heart mitral valve replacement on cardiopulmonary bypass without cross-clamping the aorta. The prospective study included 25 consecutive patients who underwent mitral valve replacement. The operations were carried out on a beating heart method using normothermic cardiopulmonary bypass without cross-clamping the aorta. All patients were evaluated preoperatively (E1) and postoperatively (at sixth day [E2] and second month [E3]) for neurocognitive functions. Neurologic deficit was not observed in the postoperative period. Comparison of the neurocognitive test results, between the preoperative and postoperative assessment for both hemispheric cognitive functions, demonstrated that no deterioration occurred. In the three subsets of left hemispheric cognitive function test evaluation, total verbal learning, delayed recall, and recognition, significant improvements were detected at the postoperative second month (E3) compared to the preoperative results (p = 0.005, 0.01, and 0.047, respectively). Immediate recall and retention were significantly improved within the first postoperative week (E2) when compared to the preoperative results (p = 0.05 and 0.05, respectively). The technique of mitral valve replacement with normothermic cardiopulmonary bypass without cross-clamping of the aorta may be safely used for majority of patients requiring mitral valve replacement without causing deterioration in neurocognitive functions.
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
21 CFR 870.3925 - Replacement heart valve.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...
Lee Henry, Christopher; Ko, Jong Mi; Henry, Albert Carl; Matter, Gregory John
2011-01-01
Aortic valve replacement following an earlier coronary artery bypass grafting (CABG) procedure is fairly common. When this situation occurs, the type of valve dysfunction is usually stenosis (with or without regurgitation), and whether it was missed at the time of the earlier CABG or developed subsequently is usually unclear. We attempted to determine the survival in patients who had had aortic valve replacement after 2 previous CABG procedures. We describe 12 patients who had aortic valve replacement for aortic stenosis; rather than one previous CABG operation, all had had 2 previous CABG procedures. Only one patient died in the early postoperative period after aortic valve replacement, and the remaining 11 were improved substantially: all have lived at least 11 months, and one is still alive at over 101 months after aortic valve replacement. Aortic valve replacement remains beneficial for most patients even after 2 previous CABG procedures. PMID:21307968
NASA Astrophysics Data System (ADS)
Vahidkhah, Koohyar; Abbasi, Mostafa; Barakat, Mohammed; Dvir, Danny; Azadani, Ali
2017-11-01
An increasingly recognized complication following surgical/transcatheter aortic valve replacement is thrombosis or blood clot formation on replacement valve leaflets. A predisposing factor in thrombus formation on biomaterial surfaces of a bioprosthetic heart valve is blood stasis. Longer residence time of blood provides an opportunity for platelets and agonists to accumulate to critical concentrations that leads to platelet activation and then thrombosis. In this study, we have developed a fluid-solid interaction (FSI) modeling approach, to quantify blood stasis on the leaflets of bioprosthetic aortic valves with different design operating in a patient-specific geometry. We have validated our FSI model against experimental measurements of valve opening/closing as well as in-vitro particle image velocimetry. We have also embedded in our method a model for transport of platelets and agonists (ADP, TxA2, and thrombin) and their interactions that result in platelets activation and adhesion to biomaterial bioprosthetic surfaces. We have provided quantitative evidence for the correlation between long residence of blood on bioprosthetic aortic valve leaflets and formation of high thrombogenicity risk regions on the leaflets that are characterized by accumulation of activated platelet.
Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt
2015-06-01
Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p < 0.0001), tricuspid valve regurgitation (mean 2.33 vs 1.3, p < 0.0001), and in right ventricular dilation, volume, and area. There was no difference in the degree of tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first postoperative month after pulmonary valve replacement, irrespective of concomitant tricuspid valve annuloplasty. The tricuspid valve appears to function better over the midterm if annuloplasty is not performed. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Complementary role of cardiac CT in the assessment of aortic valve replacement dysfunction
Moss, Alastair J; Dweck, Marc R; Dreisbach, John G; Williams, Michelle C; Mak, Sze Mun; Cartlidge, Timothy; Nicol, Edward D; Morgan-Hughes, Gareth J
2016-01-01
Aortic valve replacement is the second most common cardiothoracic procedure in the UK. With an ageing population, there are an increasing number of patients with prosthetic valves that require follow-up. Imaging of prosthetic valves is challenging with conventional echocardiographic techniques making early detection of valve dysfunction or complications difficult. CT has recently emerged as a complementary approach offering excellent spatial resolution and the ability to identify a range of aortic valve replacement complications including structural valve dysfunction, thrombus development, pannus formation and prosthetic valve infective endocarditis. This review discusses each and how CT might be incorporated into a multimodal cardiovascular imaging pathway for the assessment of aortic valve replacements and in guiding clinical management. PMID:27843568
Furuichi, Yuko; Shimizu, Jun; Sakamoto, Atsuhiro
2012-04-01
We experienced anesthesia for total arch and descending aorta replacement and aortic valve replacement for post-repair aneurysm of coarctation of aorta and aortic stenosis. Because there was possibility that post coarctectomy syndrome would occur after repair of coarctation of aorta, administration of depressor that acts on renin-angiotensin-aldosterone and careful observation were needed postoperatively. In consideration of the development of collateral vessels, preoperative imaging evaluation was added and operative method in cardiopulmonary bypass was adjusted. Careful preoperative evaluation is very important in cardiac anesthesia.
Should patients with Björk-Shiley valves undergo prophylactic replacement?
Birkmeyer, J D; Marrin, C A; O'Connor, G T
1992-08-29
About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that take account of both patient-specific and institution-specific factors are essential.
Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients
Ma, Wei-Guo; Hou, Bin; Abdurusul, Adiljan; Gong, Ding-Xu; Tang, Yue; Chang, Qian; Xu, Jian-Ping
2015-01-01
Background Dysfunction of mechanical heart valve prostheses is an unusual but potentially lethal complication after mechanical prosthetic valve replacement. We seek to report our experience with mechanical valve dysfunction regarding etiology, surgical techniques and early outcomes. Methods Clinical data of 48 patients with mechanical valve dysfunction surgically treated between October 1996 and June 2011 were analyzed. Results Mean age was 43.7±10.9 years and 34 were female (70.8%). The median interval from primary valve implantation to dysfunction was 44.5 months (range, 1 hour to 20 years). There were 21 emergent and 27 elective reoperations. The etiology was thrombosis in 19 cases (39.6%), pannus in 12 (25%), thrombosis and pannus in 11 (22.9%), improper disc orientation in 2 (4.1%), missing leaflet in 1 (2.1%), excessively long knot end in 1 (2.1%), endogenous factor in 1 (2.1%) and unidentified in 1 (2.1%). Surgical procedure was mechanical valve replacement in 37 cases (77.1%), bioprosthetic valve replacement in 7 (14.9%), disc rotation in 2 (4.2%) and excision of excessive knot end in 1 (2.1%). Early deaths occurred in 7 patients (14.6%), due to low cardiac output in 3 (6.3%), multi-organ failure in 2 (4.2%) and refractory ventricular fibrillation in 2 (4.2%). Complications occurred in 10 patients (20.8%). Conclusions Surgical management of mechanical valve dysfunction is associated with significant mortality and morbidity. Earlier identification and prompt reoperation are vital to achieving better clinical outcomes. The high incidence of thrombosis in this series highlights the need for adequate anticoagulation and regular follow-up after mechanical valve replacement. PMID:26793354
Thongprayoon, Charat; Cheungpasitporn, Wisit; Podboy, Alexander J; Gillaspie, Erin A; Greason, Kevin L; Kashani, Kianoush B
2016-11-01
The goal of this systematic review was to assess the effects of contrast media volume on transcatheter aortic valve replacement-related acute kidney injury. A literature search was performed using Medline, EMbase, the Cochrane Database of Systematic Reviews, and clinicaltrials.gov from the inception of these databases through December 2015. Studies that reported relative risk, odds ratio, or hazard ratio comparing the risks of acute kidney injury following transcatheter aortic valve replacement in patients who received high contrast media volume were included. Pooled risk ratio (RR) and 95% confidence intervals (95% CI) were calculated using a random-effect, generic inverse variance method. Four cohort studies composed of 891 patients were included in the analyses to assess the risk of acute kidney injury after transcatheter aortic valve replacement in patients who received high contrast media volume. The pooled RR of acute kidney injury after transcatheter aortic valve replacement in patients who received a large volume of contrast media was 1.41 (95% CI, 0.87 to 2.28) compared with low contrast media volume. The meta-analysis was limited to studies using standard acute kidney injury definitions, and the pooled RR of acute kidney injury in patients who received high contrast media volume is 1.12 (95% CI, 0.78 to 1.62). Our meta-analysis shows no significant association between contrast media volume and risk of acute kidney injury after transcatheter aortic valve replacement. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.
Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation
Spina, Roberto; Anthony, Chris; Muller, David WM
2015-01-01
Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674
Ugur, Murat; Byrne, John G; Bavaria, Joseph E; Cheung, Anson; Petracek, Michael; Groh, Mark A; Suri, Rakesh M; Borger, Michael A; Schaff, Hartzell V
2014-10-01
The study objective was to evaluate whether aortic valve replacement with the Trifecta valve (St Jude Medical Inc, St Paul, Minn) using simple sutures produces better hemodynamic performance than valve replacement with noneverting pledget-reinforced sutures. We analyzed prospectively acquired 1-year hemodynamic data of patients with small aortic annulus sizes who were enrolled in a multicenter trial of the Trifecta aortic valve bioprosthesis and underwent aortic valve replacement with a 19-mm or 21-mm bioprosthesis between August 2007 and November 2009. We compared preoperative clinical information and 1-year postoperative hemodynamic data for noneverting pledget-reinforced sutures (group 1) versus everting mattress sutures or simple sutures (group 2). A total of 346 patients underwent aortic valve replacement: 269 in group 1 and 77 in group 2. Preoperative demographic characteristics for the 2 groups were similar. For groups 1 and 2, the mean gradient was 10.4±4.7 mm Hg and 11.1±4.4 mm Hg for 19-mm valves, respectively, and 8.4±3.5 mm Hg and 8.8±3.6 mm Hg for 21-mm valves, respectively; the effective orifice area was 1.40 cm2 and 1.25 cm2 for 19-mm valves, respectively, and 1.57 cm2 and 1.50 cm2 for 21-mm valves, respectively. The rate of severe prosthesis-patient mismatch (indexed effective orifice area≤0.65 cm2/m2) was 18.6% (n=11) and 25% (n=6) for 19-mm valves, respectively, and 10.9% (n=20) and 16.3% (n=8) for 21-mm valves, respectively. The suture method did not affect hemodynamic performance of supra-annular bioprostheses in patients with small aortic annulus sizes. Choice of suture technique should be determined by surgeon experience and local anatomic features. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.
Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D
2017-04-01
To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.
García-Bengoechea, J B; González-Juanatey, J R; Rubio, J; Durán, D; Sierra, J
1991-01-01
Between January 1977 and January 1989, 465 pericardial bioprostheses were implanted in 424 patients. The mean age of patients was 59.1 years (range 16-81 y.) At the time of surgery, 68% of the patients suffered from chronic atrial fibrillation. Mitral valve replacement was performed in 167 patients, aortic valve replacement in 216, multiple replacement in 40 (36 mitral and aortic, 3 mitral and tricuspid, and 1 mitral, aortic and tricuspid), and 1 pulmonary valve replacement. The different types of pericardial valve used were: Ionescu-Shiley 408, Mitral Medical 23, Bioflo 30, and Hancock 4. Hospital mortality was 10.1% with an attrition rate of 1.8 episodes per 100 patients/year. The 12-year actuarial survival rate was 65.1%. No patient underwent long-term anticoagulant treatment. The first 144 patients undergoing mitral and multiple valve replacements received temporary anticoagulation for the first 8 weeks after surgery. There was no valve thrombosis observed. Altogether 19 thromboembolic events (6 early and 13 late) were clinically documented. One patient died after an embolic event. The linearized rates of thromboembolism were 1.64 episodes per 100 patients/year for mitral and multiple valve replacements and 0.33 episodes per 100 patients/year for aortic valve replacement, with an overall rate of 1.0 episodes per 100 patients/year. Excluding early thromboembolism, the linearized rate was 1.02 episodes per 100 patients/year overall. The actuarial freedom from embolism was 92.4% overall, 88.2% for the mitral and multiple valve replacement group, and 97.6% for the aortic valve replacement group at a maximum follow-up of 12 years.(ABSTRACT TRUNCATED AT 250 WORDS)
Wang, Lv; Lu, Fang-Lin; Wang, Chong; Tan, Meng-Wei; Xu, Zhi-yun
2014-12-01
The Society of Thoracic Surgeons 2008 cardiac surgery risk models have been developed for heart valve surgery with and without coronary artery bypass grafting. The aim of our study was to evaluate the performance of Society of Thoracic Surgeons 2008 cardiac risk models in Chinese patients undergoing single valve surgery and the predicted mortality rates of those undergoing multiple valve surgery derived from the Society of Thoracic Surgeons 2008 risk models. A total of 12,170 patients underwent heart valve surgery from January 2008 to December 2011. Combined congenital heart surgery and aortal surgery cases were excluded. A relatively small number of valve surgery combinations were excluded. The final research population included the following isolated heart valve surgery types: aortic valve replacement, mitral valve replacement, and mitral valve repair. The following combined valve surgery types were included: mitral valve replacement plus tricuspid valve repair, mitral valve replacement plus aortic valve replacement, and mitral valve replacement plus aortic valve replacement and tricuspid valve repair. Evaluation was performed by using the Hosmer-Lemeshow test and C-statistics. Data from 9846 patients were analyzed. The Society of Thoracic Surgeons 2008 cardiac risk models showed reasonable discrimination and poor calibration (C-statistic, 0.712; P = .00006 in Hosmer-Lemeshow test). Society of Thoracic Surgeons 2008 models had better discrimination (C-statistic, 0.734) and calibration (P = .5805) in patients undergoing isolated valve surgery than in patients undergoing multiple valve surgery (C-statistic, 0.694; P = .00002 in Hosmer-Lemeshow test). Estimates derived from the Society of Thoracic Surgeons 2008 models exceeded the mortality rates of multiple valve surgery (observed/expected ratios of 1.44 for multiple valve surgery and 1.17 for single valve surgery). The Society of Thoracic Surgeons 2008 cardiac surgery risk models performed well when predicting the mortality for Chinese patients undergoing valve surgery. The Society of Thoracic Surgeons 2008 models were suitable for single valve surgery in a Chinese population; estimates of mortality for multiple valve surgery derived from the Society of Thoracic Surgeons 2008 models were less accurate. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Cost-effectiveness of homograft heart valve replacement surgery: an introductory study.
Yaghoubi, Mohsen; Aghayan, Hamid Reza; Arjmand, Babak; Emami-Razavi, Seyed Hassan
2011-05-01
The clinical effectiveness of heart valve replacement surgery has been well documented. Mechanical and homograft valves are used routinely for replacement of damaged heart valves. Homograft valves are produced in our country but we import the mechanical valves. To our knowledge the cost-effectiveness of homograft valve has not been assessed. The objective of the present study was to compare the cost-effectiveness of homograft valve replacement with mechanical valve replacement surgery. Our samples were selected from 200 patients that underwent homograft and mechanical heart valve replacement surgery in Imam-Khomeini hospital (2000-2005). In each group we enrolled 30 patients. Quality of life was measured using the SF-36 questionnaire and utility was measured in quality-adjusted life years (QALYs). For each group we calculated the price of heart valve and hospitalization charges. Finally the cost-effectiveness of each treatment modalities were summarized as costs per QALYs gained. Forty male and twenty female participated in the study. The mean score of quality of life was 66.06 (SD = 9.22) in homograft group and 57.85 (SD = 11.30) in mechanical group (P < 0.05). The mean QALYs gained in homograft group was 0.67 more than mechanical group. The incremental cost-effectiveness ratio (ICER) revealed a cost savings of 1,067 US$ for each QALY gained in homograft group. Despite limitation of this introductory study, we concluded that homograft valve replacement was more effective and less expensive than mechanical valve. These findings can encourage healthcare managers and policy makers to support the production of homograft valves and allocate more recourse for developing such activities.
Talavlikar, P. H.; Walbaum, P. R.; Kitchin, A. H.
1973-01-01
Twelve patients undergoing aortic and 28 undergoing mitral valve replacement with autologous fascia lata valves were studied before and six months after surgery. One aortic and 10 mitral valves were found to be significantly incompetent. Of the incompetent mitral valves, two appeared to have perivalvular leaks. Six of the remainder were associated with abnormal ventricular filling patterns. Valve failure was much less common when the design was modified to provide a loose cusp structure; out of 12 such valves none was incompetent. Transvalvular gradients persist with fascial valves though they are lower than with most mechanical prostheses. Ventricular function was greatly improved in successful aortic replacement but remained impaired in the case of mitral replacement. Valve failure appeared to be associated with, or accelerated by, haemodynamic stress rather than due to inevitable degenerative pathological processes. PMID:4731108
Corynebacterium endocarditis species-specific risk factors and outcomes
Belmares, Jaime; Detterline, Stephanie; Pak, Janet B; Parada, Jorge P
2007-01-01
Background Corynebacterium species are recognized as uncommon agents of endocarditis, but little is known regarding species-specific risk factors and outcomes in Corynebacterium endocarditis. Methods Case report and Medline search of English language journals for cases of Corynebacterium endocarditis. Inclusion criteria required that cases be identified as endocarditis, having persistent Corynebacterium bacteremia, murmurs described by the authors as identifying the affected valve, or vegetations found by echocardiography or in surgical or autopsy specimens. Cases also required patient-specific information on risk factors and outcomes (age, gender, prior prosthetic valve, other prior nosocomial risk factors (infected valve, involvement of native versus prosthetic valve, need for valve replacement, and death) to be included in the analysis. Publications of Corynebacterium endocarditis which reported aggregate data were excluded. Univariate analysis was conducted with chi-square and t-tests, as appropriate, with p = 0.05 considered significant. Results 129 cases of Corynebacterium endocarditis involving nine species met inclusion criteria. Corynebacterium endocarditis typically infects the left heart of adult males and nearly one third of patients have underlying valvular disease. One quarter of patients required valve replacement and one half of patients died. Toxigenic C. diphtheriae is associated with pediatric infections (p < 0.001). Only C. amycolatum has a predilection for women (p = 0.024), while C. pseudodiphtheriticum infections are most frequent in men (p = 0.023). C. striatum, C. jeikeium and C. hemolyticum are associated with nosocomial risk factors (p < 0.001, 0.028, and 0.024, respectively). No species was found to have a predilection for any particular heart valve. C. pseudodiphtheriticum is associated with a previous prosthetic valve replacement (p = 0.004). C. jeikeium infections are more likely to require valve replacement (p = 0.026). Infections involving toxigenic C. diphtheriae and C. pseudodiphtheriticum are associated with decreased survival (p = 0.001 and 0.032, respectively). Conclusion We report the first analysis of species-specific risk factors and outcomes in Corynebacterium endocarditis. In addition to species-specific associations with age, gender, prior valvular diseases, and other nosocomial risk factors, we found differences in rates of need for valve replacement and death. This review highlights the seriousness of these infections, as up to 28% of patients required valve replacement and 43.5% died. PMID:17284316
Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair
Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.
1982-01-01
It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
Horstkotte, D; Körfer, R; Budde, T; Haerten, K; Schulte, H D; Bircks, W; Loogen, F
1983-05-01
Valve-related complications after Björk-Shiley mitral (n = 475), aortic (n = 424), or mitral-aortic implantation (n = 119) were compared to complications after St. Jude mitral (n = 173), aortic (n = 152), and St. Jude mitral and aortic (n = 63) replacements. The 1,018 consecutive patients with Björk-Shiley valves had been operated upon between 1974 and 1982, those with St. Jude valves between 1978 and 1982. All patients were placed on anticoagulant therapy with phenprocoumon early after operation and no significant intergroup differences in the effectiveness of the anticoagulant therapy were found. At a comparable follow-up time of approximately 23 months, 24 major thromboembolic episodes were observed after Björk-Shiley mitral (BSM) and 3 after St. Jude mitral valve implantation (SJM), corresponding to a thromboembolic rate of 2.82/100 patient years with BSM and 0.93/100 patient years with SJM. After aortic valve replacements, 1.93 events in 100 patient years occurred after Björk-Shiley aortic (BSA) and 0.73 after St. Jude aortic implantation (SJA). In patients with double valve replacements, these rates were 3.2 (BSM + BSA) and 0.88 (SJM + SJA), respectively. The cerebral vessels were involved in 52% and the arteries of the extremities in 22% of these major events. Six Björk-Shiley prostheses had to be replaced because of valve thrombosis. The overall incidence of severe hemorrhagic complications was 2.94/100 patient years in BSM and 1.79 in SJM. After aortic valve replacement, we found rates of 1.80/100 patient years (BSA) and 2.57/100 patient years (SJA), respectively. Intravascular hemolysis no longer seems to be a significant clinical problem. However, indications of red cell damage after heart valve replacement were significantly greater in patients with perivalvular leakage, valve thrombosis, or dysfunction than in those with normally functioning prostheses. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with concomitant perivalvular regurgitation (0.46%). One valve had to be replaced because of fracture of the outlet strut of a BSM prosthesis. Hemorrhage due to the anticoagulant treatment was thus the most frequent complication, without significant intergroup differences, while thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude implantation. This may lead to the consideration of a change in the prophylaxis of thrombus formations with the St. Jude valve, especially in aortic valve replacements with sinus rhythm.
... called anticoagulants) for the rest of their lives. Biological valves are made from animal tissue (called a ... for valve replacement (called an autograft). Patients with biological valves usually do not need to take blood- ...
Valve replacement in children: a challenge for a whole life.
Henaine, Roland; Roubertie, François; Vergnat, Mathieu; Ninet, Jean
2012-10-01
Valvular pathology in infants and children poses numerous challenges to the paediatric cardiac surgeon. Without question, valvular repair is the goal of intervention because restoration of valvular anatomy and physiology using native tissue allows for growth and a potentially better long-term outcome. When reconstruction fails or is not feasible, valve replacement becomes inevitable. Which valve for which position is controversial. Homograft and bioprosthetic valves achieve superior haemodynamic results initially but at the cost of accelerated degeneration. Small patient size and the risk of thromboembolism limit the usefulness of mechanical valves, and somatic outgrowth is an universal problem with all available prostheses. The goal of this article is to address valve replacement options for all four valve positions within the paediatric population. We review current literature and our practice to support our preferences. To summarize, a multitude of opinions and surgical experiences exist. Today, the valve choices that seem without controversy are bioprosthetic replacement of the tricuspid valve and Ross or Ross-Konno procedures when necessary for the aortic valve. On the other hand, bioprostheses may be implanted when annular pulmonary diameter is adequate; if not or in case of right ventricular outflow tract discontinuity, it is better to use a pulmonary homograft with the Ross procedure. Otherwise, a valved conduit. Mitral valve replacement remains the most problematic; the mechanical prosthesis must be placed in the annular position, avoiding oversizing. Future advances with tissue-engineered heart valves for all positions and new anticoagulants may change the landscape for valve replacement in the paediatric population. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Buch, W S; Pipkin, R D; Hancock, W D; Fogarty, T J
1975-11-01
From March 1971 through April 1975, one hundred twenty patients underwent mitral valve replacement with a Hancock "stabilized glutaraldehyde process" porcine aortic xenograft. A simultaneous canine experimental series was also carried out. In the clinical series, the early mortality was 8.3%. Actuarial analyses of all patients predicts survival at two years of 81.0% and at four years of 70.0%. The predicted survival for patients without coronary disease or prior prosthetic valve replacement is 87.5% at two years and 77.5% at four years. There were four thromboembolic episodes, a rate of 2.4% per patient-year. None were fatal. No valve failure were noted. Histologic examination and shrink temperature analysis of recovered valves show excellent tissue preservation at 40 months. The data indicate that the Hancock valve is durable, enjoys a low incidence of thromboembolism, and may be the valve of choice for mitral valve replacement.
Options for Heart Valve Replacement
... which may include human or animal donor tissue) Ross Procedure — “Borrowing” your healthy valve and moving it ... Considerations for Surgery Medications Valve Repair Valve Replacement - Ross Procedure - Newer Surgery Options - What is TAVR? - Types ...
Wang, Yin; Chen, Si; Shi, Jiawei; Li, Geng; Dong, Nianguo
2016-03-01
This study aims to compare mid-long-term clinical outcomes between patients younger than 60 years of age undergoing bioprosthetic and mechanical aortic valve replacement. From January 2002 to December 2009, patients younger than 60 years of age who received Medtronic Hancock II porcine bioprostheses were selected and compared with those who received mechanical bi-leaflet valves in the aortic position. A stepwise logistic regression propensity score identified a subset of 112 evenly matched patient-pairs. Mid-long-term outcomes of survival, valve-related reoperations, thromboembolic events and bleeding events were assessed. The follow-up was only 95.1% complete. Fourteen measurable variables were statistically similar for the matched cohort. Postoperative in-hospital mortality was 3.6% (bioprosthetic valves) and 2.7% (mechanical valves) (P = 0.700). Survival at 5 and 10 years was 96.3 and 88.7% for patients receiving bioprosthetic valve replacement versus 96.3 and 87.9% for patients receiving mechanical valve replacement (P = 0.860), respectively. At 5 and 10 years after operations, freedom from valve-related reoperation was 97.2 and 94.8% for patients receiving mechanical valve replacement, and 96.3 and 90.2% for patients receiving bioprosthetic valve replacement (P = 0.296), respectively. There was no difference between freedom from thromboembolic events (P = 0.528) and bleeding events (P = 0.128) between the matched groups during the postoperative 10 years. In patients younger than 60 years of age undergoing aortic valve replacement, mid-long-term survival rate was similar for patients receiving bioprosthetic versus mechanical valve replacement. Bioprosthetic valves were associated with a trend for a lower risk of anticoagulation treatment and did not have significantly greater likelihood of a reoperation. These findings suggest that a bioprosthetic valve may be a reasonable choice for AVR in patients younger than 60 years of age. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart Valve
Claiborne, Thomas E.; Sheriff, Jawaad; Kuetting, Maximilian; Steinseifer, Ulrich; Slepian, Marvin J.; Bluestein, Danny
2013-01-01
Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the platelet activation rates of our polymer valve and the tissue valve, indicating that similar to the latter, its recipients may not require anticoagulation. This work proves the feasibility of our optimized polymer PHV design and brings polymeric valves closer to clinical viability. PMID:23445066
Asada, Dai; Ikeda, Kazuyuki; Yamagishi, Masaaki
2017-04-01
There are a few reports of successful replacement of the left-sided systemic tricuspid valve with a mechanical valve in small infants with congenitally corrected transposition of the great arteries having Ebstein's anomaly. Tricuspid valve replacement is the preferred option when pulmonary artery banding, performed as a prelude to performing the double-switch operation, is not feasible because of severe heart failure caused by tricuspid regurgitation.
Red flag in the emergency department: fracture and primary failure of a prosthetic valve.
Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat
2005-07-01
This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.
2012-01-01
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790
Darwazah, Ahmad K
2012-06-29
Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.
Failing stentless Bioprostheses in patients with carcinoid heart valve disease.
Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut
2015-03-27
Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.
IL-10 and ET-1 as biomarkers of rheumatic valve disease
Leão, Sydney Correia; Lima, Maria Regina Menezes; do Nascimento, Hertaline Menezes; Octacilio-Silva, Shirlei; Rodrigues, Tania Maria de Andrade
2014-01-01
Objective To evaluate the immunological profile and gene expression of endothelin-1 (ET-1) in mitral valves of patients with rheumatic fever originated from a reference service in cardiovascular surgery. Methods This was a quantitative, observational and cross-sectional study. Thirty-five subjects (divided into four groups) participated in the study, 25 patients with chronic rheumatic heart disease and ten control subjects. The mean age of the sample studied was 34.5 years. Seventeen of them (48.58%) were male and 18 (51.42%) were female. Inflammatory cytokines (TNF-α, IL-4 and IL-10) were measured and ten mitral valves of patients who underwent first valve replacement were collected for determination of gene expression of endothelin-1 by real time PCR. Results Among the groups studied (patients vs. controls), there was a statistically significant difference in IL-10 levels (P=0.002), and no differences in other cytokines. Expression of endothelin-1 was observed in 70% of samples. Quantitatively, average of ET-1 expression was 62.85±25.63%. Conclusion Inflammatory cytokine IL-10 participates in the maintenance of chronicity of rheumatic fever in patients who underwent valve replacement and those who are undergoing medical treatment. The expression of endothelin-1 in heart valve lesions in patients undergoing mitral valve replacement confirms its association with inflammatory activity in rheumatic fever. PMID:24896159
Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.
Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A
2016-05-01
To demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model. The CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach. Two imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function. Our results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Aortic valve replacement for papillary fibroelastoma.
Arikan, Ali Ahmet; Omay, Oğuz; Aydın, Fatih; Kanko, Muhip; Gür, Sibel; Derviş, Emir; Yılmaz, Cansu Eda; Müezzinoğlu, Bahar
2017-06-01
Surgery is indicated for symptomatic patients with papillary fibroelastomas (PFE) on the aortic valve. The valve is commonly spared during tumor excision. Rarely, aortic valve replacement (AVR) is needed. We present a case requiring AVR for an aortic valve PFE and review the literature to determine the risk factors for failure of aortic valve-sparing techniques in patients with PFE. © 2017 Wiley Periodicals, Inc.
Schoonbeek, R C; Pieper, P G; van Slooten, Y J; Freling, H G; Sieswerda, G T; van Dijk, A P J; Jongbloed, M R M; Post, M C; Bouma, B J; Berger, R M F; Ebels, T; van Melle, J P
2016-11-01
N-terminal B‑type natriuretic peptide (NT-proBNP) is an important biomarker for the detection of heart failure. Adults with congenital heart disease (ACHD) and a prosthetic heart valve are at risk for heart failure. This study aimed to determine the value of NT-proBNP in ACHD patients with a prosthetic valve and investigate its relationship with cardiac function and exercise capacity. In this multi-centre cross-sectional observational study, data regarding medical history, echocardiography, exercise testing (VO 2 peak) and laboratory blood evaluation (including NT-proBNP) were collected in ACHD patients with a single prosthetic valve (either homografts, heterografts or mechanical valves). A total of 306 ACHD patients with pulmonary valve replacement (PVR, n = 139), aortic valve replacement (n = 141), mitral valve replacement (n = 21) or tricuspid valve replacement (n = 5) were investigated. The majority of patients (77 %) were in NYHA class I or II. Elevated NT-proBNP levels (cut-off ≥125 pg/ml) were found in 50 % of the patients, with the highest levels in patients with mitral valve replacements. In this study population, NT-proBNP levels were associated with gender (p = 0.029) and VO 2 max (p < 0.001). In PVR patients, NT-proBNP levels were associated with lower VO 2 peak, also after adjustment for age, gender and age at valve replacement in a multivariate model (p = 0.015). In patients with ACHD and a prosthetic valve, elevated NT-proBNP levels are frequently observed despite preserved NYHA class. In PVR patients, a higher NT-proBNP level was associated with a lower VO 2 peak. These results may be of importance in the ongoing discussion about the timing of valve replacement in patients with CHD.
Valve assembly having remotely replaceable bearings
Johnson, Evan R.; Tanner, David E.
1980-01-01
A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings.
Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A
2017-06-01
A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.
Aorta-atria-septum combined incision for aortic valve re-replacement
Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong
2018-01-01
This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170
Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila
2016-06-20
The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.
McClure, R Scott; Narayanasamy, Narendren; Wiegerinck, Esther; Lipsitz, Stuart; Maloney, Ann; Byrne, John G; Aranki, Sary F; Couper, Gregory S; Cohn, Lawrence H
2010-05-01
This study reviews a single institution experience with the Carpentier-Edwards pericardial aortic valve bioprosthesis, concentrating on late outcomes. From December 1991 to June 2002, 1,000 patients underwent aortic valve replacement with the Carpentier-Edwards pericardial valve (mean follow-up 6.01 +/- 3.56 years). The institutional database was reviewed. Follow-up data were acquired through telephone interviews and mail-in questionnaires. Time-to-event analyses were performed by the Kaplan-Meier method. Mean age was 74.1 years; 545 patients (54.5%) were male. Mean preoperative ejection fraction was 52.5%. Isolated aortic valve replacement occurred in 372 cases (37.2%). Combined aortic valve replacement with coronary artery bypass grafting occurred in 443 cases (44.3%). The remaining 185 patients (18.5%) underwent complex procedures with concomitant mitral, tricuspid, or arch repair. One hundred forty patients (14.0%) had prior aortic valve surgery. Follow-up was 99.4% complete. Overall operative mortality was 7.2% (72 of 1,000). There were 503 late deaths (50.3%). Age-stratified survival at 15 years was 43.7% for patients less than 65 years of age; 18.2% for patients aged 65 to 75; and 9.4% for patients aged more than 75 years. There were 26 failed bioprostheses (2.6%) requiring reoperation. Structural valve deterioration was the cause in 13 of 26 cases (50%), endocarditis in 11 of 26 (42%), and perivalvular leak in 2 of 26 (7.6%). Age-stratified freedom from reoperation due to structural valve deterioration at 15 years was 34.7% for patients less than 65 years of age; 89.4% for patients aged 65 to 75; and 99.5% for patients aged more than 75 years. The Carpentier-Edwards pericardial bioprosthesis shows long-term durability with low rates of structural failure. Copyright (c) 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Polimenakos, Anastasios C; Sathanandam, Shyam; Elzein, Chawki; Barth, Mary J; Higgins, Robert S D; Ilbawi, Michel N
2010-04-01
Aortic cusp extension valvuloplasty is increasingly used in the management of children and adolescents with aortic stenosis or regurgitation. The durability of this approach and the freedom from valve replacement are not well defined. A study was undertaken to investigate outcomes. From July 1987 to November 2008, 142 patients aged less than 19 years underwent aortic cusp extension valvuloplasty in the form of pericardial cusp extension and tricuspidization (when needed). Three patients with truncus arteriosus and severe truncal valve insufficiency were excluded. From the available follow-up data of 139 patients, 50 had bicuspid aortic valves, 40 had congenital aortic valve stenosis, 41 had combined congenital aortic valve stenosis/insufficiency, and 8 had other diagnoses. Median follow-up was 14.4 years (0.1-21.4). Long-term mortality and freedom from aortic valve replacement were studied. There were no early, intermediate, or late deaths. Z-values of left ventricular end-diastolic dimension, aortic annulus, aortic sinus diameter, and sinotubular junction diameter before aortic valve replacement were 4.2 +/- 3.11, 2.3 +/- 1.25, 4.4 +/- 1.23, and 1.84 +/- 1.28, respectively. During the follow-up period, 64 patients underwent aortic valve reinterventions. The Ross procedure was performed in 32 of 139 patients (23%) undergoing aortic cusp extension valvuloplasty. Other aortic valve replacements were undertaken after 16 aortic cusp extension valvuloplasties (11.5%). Freedom from a second aortic cusp extension valvuloplasty or aortic valve replacement at 18 years was 82.1% +/- 4.2% and 60.0% +/- 7.2%, respectively. Aortic cusp extension valvuloplasty is a safe and effective surgical option with excellent survival and good long-term outcomes in children and adolescents. The procedure provides acceptable durability and satisfactory freedom from aortic valve replacement. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Javadikasgari, Hoda; Gillinov, A Marc; Idrees, Jay J; Mihaljevic, Tomislav; Suri, Rakesh M; Raza, Sajjad; Houghtaling, Penny L; Svensson, Lars G; Navia, José L; Mick, Stephanie L; Desai, Milind Y; Sabik, Joseph F; Blackstone, Eugene H
2017-06-01
For mitral regurgitation (MR) from degenerative mitral disease in patients with coexisting coronary artery disease, the appropriate surgical strategy remains controversial. From 1985 to 2011, 1,071 adults (age 70 ± 9.3 years, 77% men) underwent combined coronary artery bypass grafting and either mitral valve repair (n = 872, 81%) or replacement (n=199, 19%) for degenerative MR. Propensity matching (177 patient pairs, 89% of possible matches) was used to compare early outcomes and time-related recurrence of MR after mitral valve repair, mitral valve reoperation, and mortality. Risk factors for death were identified with multivariable, multiphase hazard-function analysis. Patients undergoing valve replacement were older, with more valve calcification and a higher prevalence of preoperative atrial fibrillation and heart failure (all p < .0001). Among matched pairs, mitral replacement versus repair was associated with higher hospital mortality (5.0% vs 1.0%, p = .0001) and more postoperative renal failure (7.0% vs 3.2%, p = .01), reexplorations for bleeding (6.0% vs 3.1%, p = .05), and respiratory failure (14% vs 4.7%, p < .0001). Of matched patients undergoing repair, 18% had MR above 3+ by 5 years. Mitral valve durability was similar between matched groups, but survival at 15 years was 18% after replacement versus 52% after repair. Nomograms from the multivariable equation revealed that in 94% of cases, 10-year survival was calculated to be higher after repair than after replacement. In patients with coexisting degenerative mitral valve and coronary artery diseases, mitral valve repair is expected to confer a long-term survival advantage over replacement despite some recurrence of MR. When feasible, it is the procedure of choice for these patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E.
2015-01-01
Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient. PMID:26346128
Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E
2015-01-01
Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient.
Beddermann, Christoph; Norman, John C.; Cooley, Denton A.
1979-01-01
Two Jehovah's Witnesses with large ascending thoracic aortic aneurysms and aortic insufficiency secondary to annuloaortic ectasia underwent successful combined replacement of the aortic valve and the ascending aorta. One patient received a composite graft containing an aortic valve prosthesis, which necessitated supravalvular coronary ostia reimplantation; the other patient underwent separate aortic valve and left supracoronary ascending aneurysm replacement, with reimplantation of the right coronary ostium into the graft. No blood or blood derivatives were administered. Both patients had uneventful recoveries and continue to do well. To our knowledge, they represent the first reported cases of successful combined replacement of the aortic valve and ascending aorta in Jehovah's Witnesses. Images PMID:15216324
Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.
Reardon, Michael J; Van Mieghem, Nicolas M; Popma, Jeffrey J; Kleiman, Neal S; Søndergaard, Lars; Mumtaz, Mubashir; Adams, David H; Deeb, G Michael; Maini, Brijeshwar; Gada, Hemal; Chetcuti, Stanley; Gleason, Thomas; Heiser, John; Lange, Rüdiger; Merhi, William; Oh, Jae K; Olsen, Peter S; Piazza, Nicolo; Williams, Mathew; Windecker, Stephan; Yakubov, Steven J; Grube, Eberhard; Makkar, Raj; Lee, Joon S; Conte, John; Vang, Eric; Nguyen, Hang; Chang, Yanping; Mugglin, Andrew S; Serruys, Patrick W J C; Kappetein, Arie P
2017-04-06
Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910 .).
Ross procedure for ascending aortic replacement.
Elkins, R C; Lane, M M; McCue, C
1999-06-01
Patients with aortic valve disease and aneurysm or dilatation of the ascending aorta require both aortic valve replacement and treatment of their ascending aortic disease. In children and young adults, the Ross operation is preferred when the aortic valve requires replacement, but the efficacy of extending this operation to include replacement of the ascending aorta or reduction of the dilated aorta has not been tested. We reviewed the medical records of 18 (5.9%) patients with aortic valve disease and an ascending aortic aneurysm and 26 (8.5%) patients with dilation of the ascending aorta, subgroups of 307 patients who had a Ross operation between August 1986 and February 1998. We examined operative and midterm results, including recent echocardiographic assessment of autograft valve function and ability of the autograft root and ascending aortic repair or replacement to maintain normal structural integrity. There was one operative death (2%) related to a perioperative stroke. Forty-two of 43 survivors have normal autograft valve function, with trace to mild autograft valve insufficiency, and one patient has moderate insufficiency at the most recent echocardiographic evaluation. None of the patients has dilatation of the autograft root or of the replaced or reduced ascending aorta. Early results with extension of the Ross operation to include replacement of an ascending aortic aneurysm or vertical aortoplasty for reduction of a dilated ascending aorta are excellent, with autograft valve function equal to that seen in similar patients without ascending aortic disease.
Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra
2017-04-26
Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence
NASA Astrophysics Data System (ADS)
Liang, Liang; Martin, Caitlin; Wang, Qian; Sun, Wei; Duncan, James
2016-03-01
Aortic valve (AV) disease is a significant cause of morbidity and mortality. The preferred treatment modality for severe AV disease is surgical resection and replacement of the native valve with either a mechanical or tissue prosthetic. In order to develop effective and long-lasting treatment methods, computational analyses, e.g., structural finite element (FE) and computational fluid dynamic simulations, are very effective for studying valve biomechanics. These computational analyses are based on mesh models of the aortic valve, which are usually constructed from 3D CT images though many hours of manual annotation, and therefore an automatic valve shape reconstruction method is desired. In this paper, we present a method for estimating the aortic valve shape from 3D cardiac CT images, which is represented by triangle meshes. We propose a pipeline for aortic valve shape estimation which includes novel algorithms for building local shape dictionaries and for building landmark detectors and curve detectors using local shape dictionaries. The method is evaluated on real patient image dataset using a leave-one-out approach and achieves an average accuracy of 0.69 mm. The work will facilitate automatic patient-specific computational modeling of the aortic valve.
Elahi, Maqsood M; Choi, Charles H; Konda, Subbareddy; Shake, Jay G
2015-01-01
This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical prosthesis. Nattokinase is an enzyme derived from a popular fermented soybean preparation in Japan (natto), which has fibrinolytic properties and is gaining popularity in nontraditional health journals and nonmedical health websites as an over-the-counter thrombolytic. After nearly a year of use of nattokinase without warfarin, the patient developed thrombus on the mechanical valve and underwent successful repeat valve replacement. We believe this is the first documented case of nattokinase being used as a substitute for warfarin after valve replacement, and we strongly discourage its use for this purpose.
Elahi, Maqsood M.; Choi, Charles H.; Konda, Subbareddy
2015-01-01
This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical prosthesis. Nattokinase is an enzyme derived from a popular fermented soybean preparation in Japan (natto), which has fibrinolytic properties and is gaining popularity in nontraditional health journals and nonmedical health websites as an over-the-counter thrombolytic. After nearly a year of use of nattokinase without warfarin, the patient developed thrombus on the mechanical valve and underwent successful repeat valve replacement. We believe this is the first documented case of nattokinase being used as a substitute for warfarin after valve replacement, and we strongly discourage its use for this purpose. PMID:25552810
Aydin, Unal; Gul, Mehmet; Aslan, Serkan; Akkaya, Emre; Yildirim, Aydin
2015-04-28
Transcatheter valve implantation is a novel interventional technique, which was developed as an alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.
Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.
Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari
2017-06-01
Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.
Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.
Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D
2017-08-01
The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.
Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.
Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A
2017-10-01
The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p < 0.001). Early pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Booth, K; Beattie, R; McBride, M; Manoharan, G; Spence, M; Jones, J M
2016-01-01
Deciding on the optimal treatment strategy for high risk aortic valve replacement is challenging. Transcatheter Aortic Valve implantation (TAVI) has been available in our centre as an alternative treatment modality for patients since 2008. We present our early experience of TAVI and SAVR (surgical Aortic Valve Replacement) in high risk patients who required SAVR because TAVI could not be performed. The database for Surgical aortic valve and Transcatheter aortic valve replacement referrals was interrogated to identify relevant patients. Survival to hospital discharge was 95.5% in the forty five patients who had SAVR when TAVI was deemed technically unsuitable. One year survival was 86%. Defining who is appropriate for TAVI or high risk SAVR is challenging and multidisciplinary team discussion has never been more prudent in this field of evolving technology with ever decreasing risks of surgery. The introduction of TAVI at our institution has seen a rise in our surgical caseload by approximately by 25%. Overall, the option of aortic valve intervention is being offered to more patients in general which is a substantial benefit in the treatment of aortic valve disease.
The Ross operation: a 12-year experience.
Elkins, R C
1999-09-01
The Ross operation, originally introduced as a scalloped subcoronary implant with an 80% survival and 85% freedom from reoperation, has recently been modified to a root replacement which is now the most utilized implant technique. The mid and late results of this operative technique and comparison of intra-aortic implants and root replacement in a single institution are reported. The records of 328 patients who had a Ross operation at the University of Oklahoma (August 1986 to July 1998) were reviewed to assess operative technique and patient-related factors on survival, autograft valve function, homograft valve function, valve-related complications, and need for reoperation. Operative survival was 95.4% with an actuarial survival of 89% +/- 5% at 8 years. Freedom from replacement of the pulmonary autograft was 94% +/- 3% at 8 years, freedom from reoperation on the pulmonary homograft was 90% +/- 4% at 8 years, and freedom from autograft valve reoperation or dysfunction (3+ autograft valve insufficiency) was 83% +/- 6% at 9 years. The incidence of autograft valve reoperation and late autograft valve dysfunction was decreased by root replacement. Annulus reduction and fixation improved early results in patients with aortic insufficiency and annulus dilatation. Early results have been excellent, as the development of late autograft valve dysfunction or dilatation has been rare. The excellent hemodynamic results with a limited incidence of reoperation and replacement of the autograft valve justify its continued use.
Mitral valve replacement with preservation of the subvalvular apparatus.
Reardon, M J; David, T E
1999-03-01
The introduction of the Starr-Edwards valve allowed complete replacement of diseased left-sided heart valves. With improved cardiopulmonary bypass, myocardial protection, and surgical techniques the mortality rate from aortic valve replacement decreased substantially, whereas the mortality rate from mitral valve replacement remained high, largely because of low cardiac output syndrome. Increasing use of mitral valve repair techniques resulted in a marked decrease in short-term and long-term morbidity and mortality when treating patients with mitral regurgitation. Some believed that this resulted from maintenance of the mitral annular papillary muscle continuity during mitral valve repair. Subsequent experimental and clinical studies have validated the positive short-term and long-term effects of maintaining the integrity of the mitral valve subvalvular apparatus. This article considers the history of the clinical use of preservation of the subvalvular apparatus, the physiologic studies examining this concept, and the clinical data available on its use. It also examines the following: 1) mitral stenosis versus mitral regurgitation and the preservation of the subvalvular apparatus; 2) whether the anterior, posterior, or both areas of the subvalvular apparatus should be preserved; and 3) the surgical techniques for the preservation of the subvalvular apparatus and valve implantation.
Crowley, Olivia M; Doty, John R
2017-07-01
Aortic root replacement is indicated for aortic root aneurysm, small aortic root, and most root abscesses. This report describes the placement of a radiopaque marker during aortic root replacement using a Freestyle porcine bioprosthesis. This marker is a useful landmark during fluoroscopy for transcatheter valve-in-valve aortic valve replacement in the event of bioprosthesis degeneration. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Pledget Induced Cardiogenic Shock Following a Minimally Invasive Aortic Valve Replacement.
Tedesco, Alexandra E; Tedesco, Victor E
2017-01-01
Within the last decade, minimally invasive valve replacements have become exceedingly popular, and as a result, so has the rise of technology aimed at refining and simplifying these techniques. With new technology, new complications are inevitable. We present a routine Minimally invasive aortic valve replacement through a right anterior minithoracotomy complicated by pledget impaction in a coronary artery.
McNeely, Christian A; Vassileva, Christina M
2015-01-01
The short-term advantage of mitral valve repair versus replacement for degenerative disease has been extensively documented. These advantages include lower operative mortality, improved survival, better preservation of left-ventricular function, shorter post-operative hospital stay, lower total costs, and fewer valve-related complications, including thromboembolism, anticoagulation-related bleeding events and late prosthetic dysfunction. More recent written data are available indicating the long-term advantage of repair versus replacement. While at some institutions, the repair rate for degenerative disease may exceed 90%, the national average in 2007 was only 69%. Making direct comparisons between mitral valve repair and replacement using the available studies does present some challenges however, as there are often differences in baseline characteristics between patient groups as well as other dissimilarities between studies. The purpose of this review is to systematically summarize the long-term survival and reoperation data of mitral valve repair versus replacement for degenerative disease. A PubMed search was done and resulted in 12 studies that met our study criteria for comparing mitral valve repair versus replacement for degenerative disease. A systematic review was then conducted abstracting survival and reoperation data. PMID:25158683
Echocardiographic Assessment of Heart Valve Prostheses
Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio
2014-01-01
Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917
Mizuno, T; Mizukoshi, T; Uechi, M
2013-02-01
Mitral valve repair under cardiopulmonary bypass was performed in three dogs with clinical signs associated with mitral regurgitation that were not controlled by medication. Mitral valve repair comprised circumferential annuloplasty and chordal replacement with expanded polytetrafluoroethylene. One dog died 2 years after surgery because of severe mitral regurgitation resulting from partial circumferential suture detachment. The others survived for over 5 years, but mild mitral valve stenosis persisted in one. The replaced chordae did not rupture in any dog. Mitral valve repair appears to be an effective treatment for mitral regurgitation in dogs. Chordal replacement with expanded polytetrafluoroethylene is a feasible technique, demonstrating long-term durability in dogs. However, mitral annuloplasty techniques need improvement. © 2012 British Small Animal Veterinary Association.
Yu, Pey-Jen; Mattia, Allan; Cassiere, Hugh A; Esposito, Rick; Manetta, Frank; Kohn, Nina; Hartman, Alan R
2017-12-29
Significant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The aim of this study is to determine if surgical correction of both aortic and mitral valves in high risk patients with concomitant valvular disease would offer patients better outcomes than TAVR alone. A retrospective analysis of 43 high-risk patients who underwent concomitant surgical aortic valve replacement and mitral valve surgery from 2008 to 2012 was performed. Immediate and long term survival were assessed. There were 43 high-risk patients with severe aortic stenosis undergoing concomitant surgical aortic valve replacement and mitral valve surgery. The average age was 80 ± 6 years old. Nineteen (44%) patients had prior cardiac surgery, 15 (34.9%) patients had chronic obstructive lung disease, and 39 (91%) patients were in congestive heart failure. The mean Society of Thoracic Surgeons Predicted Risk of Mortality for isolated surgical aortic valve replacement for the cohort was 10.1% ± 6.4%. Five patients (11.6%) died during the index admission and/or within thirty days of surgery. Mortality rate was 25% at six months, 35% at 1 year and 45% at 2 years. There was no correlation between individual preoperative risk factors and mortality. High-risk patients with severe aortic stenosis and mitral valve disease undergoing concomitant surgical aortic valve replacement and mitral valve surgery may have similar long term survival as that described for such patients undergoing TAVR. Surgical correction of double valvular disease in this patient population may not confer mortality benefit compared to TAVR alone.
Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio
2015-07-01
A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.
Aortic valve replacement using continuous suture technique in patients with aortic valve disease.
Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku
2013-08-01
The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.
A new paradigm for obtaining marketing approval for pediatric-sized prosthetic heart valves.
Yoganathan, Ajit P; Fogel, Mark; Gamble, Susan; Morton, Michael; Schmidt, Paul; Secunda, Jeff; Vidmar, Sara; Del Nido, Pedro
2013-10-01
Congenital heart valve disease is one of the most common abnormalities in children. There are limited technological solutions available for treating children with congenital heart valve diseases. The aim of this study is to provide the details of the consensus reached in terms of pediatric definitions, design approach, in vitro testing, and clinical trials, which may be used as guidance for developing prosthetic heart valves for the pediatric indication. In stark contrast to the various designs of adult-sized replacement valves available in the market, there are no Food and Drug Administration (FDA)-approved prosthetic heart valves available for use in the pediatric population. There is a pressing need for FDA-approved pediatric valve devices in the United States. The pediatric patient population has been typically excluded from replacement heart valve trials for several reasons. In January 2010, heart valve manufacturers and pediatric clinicians collaborated with academicians and FDA staff in a workshop to suggest ways to successfully evaluate pediatric prosthetic valves and conduct pediatric clinical trials to provide acceptable heart valve replacement options for this patient population. Recommendations, derived from ISO 5840:2005 and the 2010 FDA Draft Replacement Heart Valve Guidance, are provided for hydrodynamic, durability, and fatigue testing. The article specifically addresses in vitro and premarket and postmarket approval clinical studies that should be considered by a heart valve manufacturer for obtaining regulatory approval of pediatric sizes of prosthetic heart valve designs that are already approved for adult clinical use. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Late leaflet fracture and embolization of a Duromedics mitral prosthesis.
Sudo, K; Sasagawa, N; Ide, H; Nunokawa, M; Fujiki, T; Tonari, K
2000-08-01
A case of leaflet fracture and embolization of a mitral prosthetic valve is described. A 54-year-old man had received mitral valve replacement with an Edwards-Duromedics 29M prosthetic valve, at 10 years ago. Emergency mitral valve replacement was performed because the patient had severe congestive left heart failure with severe acute mitral regurgitation caused by a fracture in one of the mitral valve leaflets. The leaflet, which was fractured into 2 pieces, was removed from the right common iliac artery at 3 months after valve replacement. Visual inspection revealed that the leaflet contained a midline fracture. The fracture originated within a cavitary erosion pit near the major radius of the leaflet. The patient recovered from acute renal failure, requiring hemodialysis for 80 days, and is currently without complaints. We have used a Duromedics mitral valve in 11 patients, from April 1987 to April 1988. No subsequent valve failure has occurred. The diagnosis, treatment and cause of a mechanical valve fracture are discussed.
A technique of snaring method for fitting a prosthetic valve into the annulus.
Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki
2005-01-01
Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.
Factors influencing mortality after bioprosthetic valve replacement; a midterm outcome.
Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar
2013-01-01
Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population.
Contemporary experience with surgical treatment of aortic valve disease in children.
Khan, Muhammad S; Samayoa, Andres X; Chen, Diane W; Petit, Christopher J; Fraser, Charles D
2013-09-01
Surgical treatment of aortic valve (AoV) disease in childhood involves complex decisions particularly in very small patients. There is no consensus regarding the optimum surgical option. The objective of this review was to analyze a contemporary experience of AoV surgery in a large children's hospital. A retrospective review of children (aged ≤ 18 years) undergoing AoV repair or replacement from June 1995 to December 2011 was carried out. A total of 285 AoV operations (97 repairs, 188 replacements) were performed on 241 patients. Hospital survival for repair was 98% and for replacements was 97%. At follow-up of repairs, there were 16 (17%) reoperations and 3 (3%) late deaths. Follow-up of AoV replacements demonstrated 31 (16%) reoperations (homograft 27, autograft 3, mechanical 1) and 8 (4%) late deaths (homograft 5, autograft 2, mechanical 1). Freedom from reintervention or death (FRD) was found to be lower in repairs for infants (P = .048) and truncal valves (P < .05). For AoV replacements, infants and patients who had concomitant CHD or homografts (P < .0001) had lower FRD. Cox regression analysis for AoV replacements identified infants and homograft root replacements at a higher risk for death/reoperation. AoV repairs and replacements were generally found to be associated with low death and reoperation rates at long-term follow-up. Infants had a lower freedom from reintervention or death after either an AoV repair or replacement, although truncal valve repairs and AoV replacement in patients with concomitant CHD were associated with lower valve survival. Among the valve options, homograft root replacement had a higher risk of death/reoperation and lowest freedom from reintervention or death. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Svensson, Lars G; Pillai, Saila T; Rajeswaran, Jeevanantham; Desai, Milind Y; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Thamilarasan, Maran; Roselli, Eric E; Pettersson, Gösta B; Gillinov, A Marc; Navia, Jose L; Smedira, Nicholas G; Sabik, Joseph F; Lytle, Bruce W; Blackstone, Eugene H
2016-03-01
To evaluate long-term results of aortic root procedures combined with ascending aorta replacement for aneurysms, using 4 surgical strategies. From January 1995 to January 2011, 957 patients underwent 1 of 4 aortic root procedures: valve preservation (remodeling or modified reimplantation, n = 261); composite biologic graft (n = 297); composite mechanical graft (n = 156); or allograft root (n = 243). Seven deaths occurred (0.73%), none after valve-preserving procedures, and 13 strokes (1.4%). Composite grafts exhibited higher gradients than allografts or valve preservation, but the latter 2 exhibited more aortic regurgitation (2.7% biologic and 0% mechanical composite grafts vs 24% valve-preserving and 19% allografts at 10 years). Within 2 to 5 years, valve preservation exhibited the least left ventricular hypertrophy, allograft replacement the greatest; however, valve preservation had the highest early risk of reoperation, allograft replacement the lowest. Patients receiving allografts had the highest risk of late reoperation (P < .05), and those receiving composite mechanical grafts and valve preservation had the lowest. Composite bioprosthesis patients had the highest risk of late death (57% at 15 years vs 14%-26% for the remaining procedures, P < .0001), because they were substantially older and had more comorbidities (P < .0001). These 4 aortic root procedures, combined with ascending aorta replacement, provide excellent survival and good durability. Valve-preserving and allograft procedures have the lowest gradients and best ventricular remodeling, but they have more late regurgitation, and likely, less risk of valve-related complications, such as bleeding, hemorrhage, and endocarditis. Despite the early risk of reoperation, we recommend valve-preserving procedures for young patients when possible. Composite bioprostheses are preferable for the elderly. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Preservation of the bicuspid aortic valve.
Schäfers, Hans-Joachim; Aicher, Diana; Langer, Frank; Lausberg, Henning F
2007-02-01
Bicuspid anatomy of the aortic valve is a common reason for aortic regurgitation and is associated with aortic dilatation in more than 50% of patients. We have observed different patterns of aortic dilatation and used different approaches preserving the valve. Between October 1995 and February 2006, a regurgitant bicuspid valve was repaired in 173 patients. The aorta was normal in 57 patients who underwent isolated repair. Aortic dilatation mainly above commissural level (n = 38) was treated by separate valve repair plus supracommissural aortic replacement. In 78 patients, aortic dilatation involved the root and was treated by root remodeling. Hospital mortality and perioperative morbidity were low in all three groups. Myocardial ischemia was significantly shorter in repair plus aortic replacement than remodeling (p < 0.001). Freedom from aortic regurgitation II or greater at 5 years varied between 91% and 96%. Freedom from reoperation at 5 years was 97% after remodeling, but only 53% after repair plus aortic replacement (p = 0.33). Symmetric prolapse was the most frequent cause for reoperation. The long-term stability of bicuspid aortic valve repair is excellent in the absence of aortic pathology. In the presence of aortic dilatation, root remodeling leads to equally stable valve durability. In patients with less pronounced root dilatation, separate valve repair plus aortic replacement may be a less complex alternative. Symmetric prolapse should be avoided if the ascending aorta is replaced.
Open heart surgery after renal transplantation.
Yamamura, Mitsuhiro; Miyamoto, Yuji; Mitsuno, Masataka; Tanaka, Hiroe; Ryomoto, Masaaki; Fukui, Shinya; Tsujiya, Noriko; Kajiyama, Tetsuya; Nojima, Michio
2014-09-01
to evaluate the strategy for open heart surgery after renal transplantation performed in a single institution in Japan. we reviewed 6 open heart surgeries after renal transplantation in 5 patients, performed between January 1992 and December 2012. The patients were 3 men and 2 women with a mean age of 60 ± 11 years (range 46-68 years). They had old myocardial infarction and unstable angina, aortic and mitral stenosis, left arterial myxoma, aortic stenosis, and native valve endocarditis followed by prosthetic valve endocarditis. Operative procedures included coronary artery bypass grafting, double-valve replacement, resection of left arterial myxoma, 2 aortic valve replacements, and a double-valve replacement. Renal protection consisted of steroid cover (hydrocortisone 100-500 mg or methylprednisolone 1000 mg) and intravenous immunosuppressant infusion (cyclosporine 30-40 mg day(-1) or tacrolimus 1.0 mg day(-1)). 5 cases were uneventful and good renal graft function was maintained at discharge (serum creatinine 2.1 ± 0.5 mg dL(-1)). There was one operative death after emergency double-valve replacement for methicillin-resistant Staphylococcus aureus-associated prosthetic valve endocarditis. Although the endocarditis improved after valve replacement, the patient died of postoperative pneumonia on postoperative day 45. careful perioperative management can allow successful open heart surgery after renal transplantation. However, severe complications, especially methicillin-resistant Staphylococcus aureus infection, may cause renal graft loss. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Siregar, Sabrina; de Heer, Frederiek; Groenwold, Rolf H H; Versteegh, Michel I M; Bekkers, Jos A; Brinkman, Emile S; Bots, Michiel L; van der Graaf, Yolanda; van Herwerden, Lex A
2014-09-01
The aim was to describe procedural volumes, patient risk profile and outcomes of heart valve surgery in the past 16 years in Netherlands. The Dutch National Database for Cardio-Thoracic Surgery includes approximately 200 000 cardiac operations performed between 1995 and 2010. Information on all valve surgeries (56 397 operations) was extracted. We determined trends for changes in procedural volume, demographics, risk profile and in-hospital mortality of valve operations. Because of incomplete data in the first years of registration, the total number of operations in those years was estimated using Poisson regression. For a subset from 2007 to 2010, follow-up data were available. Survival status was obtained through linkage with the national Cause of Death Registry, and survival analysis was performed using Kaplan-Meier method. Information on discharge and readmissions was obtained from the National Hospital Discharge Registry. The annual volume of heart valve operations increased by more than 100% from an estimated 2431 in 1995 to 5906 in 2010. Adjusted for population size in Netherlands, the number of operations per 100 000 adults increased from 20 in 1995 to 43 in 2010. In 2010, frequently performed valve surgery included the following: 34.6% isolated aortic valve (AoV) replacement, 21.8% AoV replacement and coronary artery bypass grafting (CABG), 14.6% isolated mitral valve surgery (repair or replacement) and 9.1% mitral valve and CABG. In AoV surgery, an increasing use of bioprostheses in all age categories is observed. In mitral valve surgery, 75.4% was performed by repair rather than replacement in 2010. In-hospital mortality for all valve surgery decreased significantly from 4.6% in 2007 to 3.6% in 2010, whereas the mean logistic EuroSCORE remained stable (median 5.8, P = 1.000). Thirty-day mortality after all valve surgery was 3.9% and 120-day mortality was 6.5%. At 1 year, survival after all valve surgery was 91.6% and a reoperation had been performed in 1.6%. The median postoperative length of stay was 7 days (interquartile range (IQR) 5-11) in the primary hospital and 11 days (IQR 8-16), including subsequent stay, in the secondary hospital. The results of this study provide a comprehensive overview of valve surgery trends and outcomes in Netherlands. The number of heart valve operations performed in Netherlands has increased since 1995. The significant decrease in mortality and unchanged EuroSCORE between 2007 and 2010 might reflect a general improvement of the safety of valve surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Will Catheter Interventions Replace Surgery for Valve Abnormalities?
O’Byrne, Michael L; Gillespie, Matthew J
2015-01-01
Purpose of Review Catheter-based valve technologies have evolved rapidly over the last decade. Transcatheter aortic valve replacement (TAVR) has become a routine procedure in high-risk adult patients with calcific aortic stenosis. In patients with congenital heart disease (CHD), transcatheter pulmonary valve replacement represents a transformative technology for right ventricular outflow tract dysfunction with the potential to expand to other indications. This review aims to summarize 1) the current state of the art for transcatheter valve replacement (TVR) in CHD, 2) the expanding indications for TVR, and 3) the technological obstacles to optimizing TVR. Recent findings Multiple case series have demonstrated that TVR with the Melody transcatheter pulmonary valve in properly selected patients is safe, effective, and durable in short-term follow-up. The Sapien transcatheter heart valve represents an alternative device with similar safety and efficacy in limited studies. Innovative use of current valves has demonstrated the flexibility of TVR, while highlighting the need for devices to address the broad range of post-operative anatomies either with a single device or strategies to prepare the outflow tract for subsequent device deployment. Summary The potential of TVR has not been fully realized, but holds promise in treatment of CHD. PMID:24281347
Glaser, Natalie; Jackson, Veronica; Franco-Cereceda, Anders; Sartipy, Ulrik
2018-05-17
Bovine and porcine bioprostheses are commonly used for surgical aortic valve replacement. It is unknown if the long-term survival differs between the two valve types.We performed a systematic review and meta-analysis to compare survival in patients who underwent aortic valve replacement and received a bovine or a porcine prosthesis. We performed a systematic search of Medline, Embase, Web of Science, and the Cochrane Library. Cohort studies that compared survival between patients who underwent aortic valve replacement and received either a bovine or a porcine bioprosthesis and that reported overall long-term survival with hazard ratio (HR) and 95% confidence interval (CI) were included. Two authors independently reviewed articles considered for inclusion, extracted the information from each study, and performed the quality assessment. We performed a meta-analysis using a random effects model to calculate the pooled HR (95% CI) for all-cause mortality. We did sensitivity analyses to assess the robustness of our findings. Seven studies published between 2010 and 2015 were included, and the combined study population was 49,190 patients. Of these, 32,235 (66%) received a bovine, and 16,955 (34%) received a porcine bioprosthesis. There was no significant difference in all-cause mortality between patients who received a bovine compared with a porcine bioprosthesis (pooled HR 1.00, 95% CI: 0.92-1.09). Heterogeneity between studies was moderate (55.8%, p = 0.04). This systematic review and meta-analysis suggest no difference in survival between patients who received a bovine versus a porcine bioprosthesis after aortic valve replacement. Our study provides valuable evidence for the continuing use of both bovine and porcine bioprosthetic valves for surgical aortic valve replacement. Georg Thieme Verlag KG Stuttgart · New York.
[Valvular heart disease associated with coronary artery disease].
Yildirir, Aylin
2009-07-01
Nowadays, age-related degenerative etiologies have largely replaced the rheumatic ones and as a natural result of this etiologic change, coronary artery disease has become associated with valvular heart disease to a greater extent. Degenerative aortic valve disease has an important pathophysiological similarity to atherosclerosis and is the leader in this association. There is a general consensus that severely stenotic aortic valve should be replaced during bypass surgery for severe coronary artery disease. For moderate degree aortic stenosis, aortic valve replacement is usually performed during coronary bypass surgery. Ischemic mitral regurgitation has recently received great attention from both diagnostic and therapeutic points of view. Ischemic mitral regurgitation significantly alters the prognosis of the patient with coronary artery disease. Severe ischemic mitral regurgitation should be corrected during coronary bypass surgery and mitral valve repair should be preferred to valve replacement. For moderate degree ischemic mitral regurgitation, many authors prefer valve surgery with coronary bypass surgery. In this review, the main characteristics of patients with coronary artery disease accompanying valvular heart disease and the therapeutic options based on individual valve pathology are discussed.
[Pannus Formation Two Years after Bioprosthetic Aortic Valve Implantation;Report of a Case].
Ono, Kimiyo; Kuroda, Hiroaki
2015-08-01
We report a case of early deterioration of the bioprosthetic aortic valve 23 months postoperatively. A 77-year-old man who had undergone aortic valve replacement with a 23-mm Epic valve( St. Jude Medical [SJM])presented to us after a syncopal episode. Echocardiography revealed severe aortic stenosis, and redo aortic valve replacement with a 21-mm SJM mechanical valve was performed. All 3 cusps of the tissue valve were thickened by fibrous pannus overgrowth. Neither calcification nor invasion of inflammatory cells was observed. The cause of pannus formation at such an early stage after implantation remains unknown.
Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.
Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael
2017-11-01
Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie
2016-01-01
Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu
Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less
Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M
2014-09-01
The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin
2014-08-01
Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.
TAVR and SAVR: Current Treatment of Aortic Stenosis.
Hu, Patrick P
2012-01-01
Transcatheter aortic valve replacement (TAVR) was approved in the United States in late 2011, providing a critically needed alternative therapy for patients with severe aortic stenosis previously refused surgical aortic valve replacement (SAVR). Over 20,000 TAVR have been performed in patients worldwide since 2002 when Alain Cribier performed the first-in-man TAVR. This paper reviews the data from balloon expandable and self-expanding aortic stent valves as well as data comparing them with traditional surgical aortic valve replacement (SAVR). Complications using criteria established by the Valve Academic Research Consortium (VARC) are reviewed. Future challenges and possibilities are discussed and will make optimizing TAVR an important goal in the years to come.
TAVR and SAVR: Current Treatment of Aortic Stenosis
Hu, Patrick P.
2012-01-01
Transcatheter aortic valve replacement (TAVR) was approved in the United States in late 2011, providing a critically needed alternative therapy for patients with severe aortic stenosis previously refused surgical aortic valve replacement (SAVR). Over 20,000 TAVR have been performed in patients worldwide since 2002 when Alain Cribier performed the first-in-man TAVR. This paper reviews the data from balloon expandable and self-expanding aortic stent valves as well as data comparing them with traditional surgical aortic valve replacement (SAVR). Complications using criteria established by the Valve Academic Research Consortium (VARC) are reviewed. Future challenges and possibilities are discussed and will make optimizing TAVR an important goal in the years to come. PMID:22952419
Valve exploiting the principle of a side channel turbine
NASA Astrophysics Data System (ADS)
Jandourek, Pavel; Habán, Vladimír; Pochylý, František; Fic, Miloslav
The article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Reducing valves are a source of hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the valve and the turbine. The basis for the design is the loss characteristics of the valve. Thereby creating a kind of turbine valve with speed-controlled flow in dependence of runner revolution.
Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr
2015-05-01
Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Aortic Root Replacement for Children With Loeys-Dietz Syndrome.
Patel, Nishant D; Alejo, Diane; Crawford, Todd; Hibino, Narutoshi; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A
2017-05-01
Loeys-Dietz syndrome (LDS) is an aggressive aortopathy with a proclivity for aortic aneurysm rupture and dissection at smaller diameters than other connective tissue disorders. We reviewed our surgical experience of children with LDS to validate our guidelines for prophylactic aortic root replacement (ARR). We reviewed all children (younger than 18 years) with a diagnosis of LDS who underwent ARR at our institution. The primary endpoint was mortality, and secondary endpoints included complications and the need for further interventions. Thirty-four children with LDS underwent ARR. Mean age at operation was 10 years, and 15 (44%) were female. Mean preoperative root diameter was 4 cm. Three children (9%) had composite ARR with a mechanical prosthesis, and 31 (91%) underwent valve-sparing ARR. Concomitant procedures included arch replacement in 2 (6%), aortic valve repair in 1 (3%), and patent foramen ovale closure in 16 (47%). There was no operative mortality. Two children (6%) required late replacement of the ascending aorta, 5 (15%) required arch replacement, 1 (3%) required mitral valve replacement, and 2 (6%) had coronary button aneurysms/pseudoaneurysms requiring repair. Three children required redo valve-sparing ARR after a Florida sleeve procedure, and 2 had progressive aortic insufficiency requiring aortic valve replacement after a valve-sparing procedure. There were 2 late deaths (6%). These data confirm the aggressive aortopathy of LDS. Valve-sparing ARR should be performed when feasible to avoid the risks of prostheses. Serial imaging of the arterial tree is critical, given the rate of subsequent intervention. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bradley, Scott M
2013-10-01
The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.
Li, Mingwen; Xiao, Yingbin; Chen, Daozhong; Liu, Liming; Ma, Liming; Wang, Pingfan; Jia, Kui; Yang, Kai; Chen, Lin
2016-05-18
Star GK valves were widely used in China, and we studied the clinical follow-up results of patients with Star GK valve implants for more than one year. Clinical data were collected from those patients who had Star GK valve implants for over one year. Patients were divided into three groups: (1) AVR group: received aortic valve replacement surgery. Based on the valve model this group was further sub-divided into two groups: 21A group, and 23A group; (2) MVR group: received mitral valve replacement surgery. Based on the valve model this group was further sub-divided into three groups: 25M group, 27M group, and 29M group; (3) DVR group: received combined replacement surgeries including AVR + MVR. According to postoperative follow-up time these patients were divided into two groups: 1-year group and 3-year group. Follow-up data were collected by telephone, outpatient visits, or correspondence. Clinical data were aggregated by professional data scientists to conduct independent analyses. 959 patients were included in the study following Star GK valve implant. Follow-up after 1 year found that thrombosis occurred in 4 cases, hemorrhage in 15 cases, left heart failure in 13 cases, paravalvular leakage in 5 cases, and death due to cardiac causes in 2 cases. The long-term efficacy of Star GK valve implants was satisfactory with low incidence of valve-related complications, and following Star GK valve implant, valve and blood were highly compatible and blood component damage was minor. Very low incidence rate of thrombosis was observed following Star GK valve implant, however, attention should be paid to adjust the anticoagulation intensity.
Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun
2014-01-01
Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. Conclusions This design of the novel ePTFE transcatheter pulmonary valve is safe and effective to deploy in sheep by hybrid approach, and the early valvular functionality is good. PMID:24926892
Urbanski, Paul P.; Lenos, Aristidis; Irimie, Vadim; Bougioukakis, Petros; Zacher, Michael; Diegeler, Anno
2016-01-01
OBJECTIVES The aim of the study was to evaluate operative and long-term results after surgery of acute aortic dissection involving the root, in which the proximal repair consisted of curative resection of all dissected aortic sinuses and was performed using either valve-sparing root repair or complete root replacement with a valve conduit. METHODS Between August 2002 and March 2013, 162 consecutive patients (mean age 63 ± 14 years) underwent surgery for acute type A aortic dissection. Eighty-six patients with an involvement of the aortic root underwent curative surgery of the proximal aorta consisting of valve-sparing root repair (n = 54, 62.8%) or complete valve and root replacement using composite valve grafts (n = 32, 37.2%). In patients with root repair, all dissected aortic walls were resected and root remodelling using the single patch technique (n = 53) or root repair with valve reimplantation (n = 1) was performed without the use of any glue. All perioperative data were collected prospectively and retrospective statistical examination was performed using univariate and multivariate analyses. RESULTS The mean follow-up was 5.2 ± 3.5 years for all patients (range 0–12 years) and 6.1 ± 3.3 years for survivors. The 30-day mortality rate was 5.8% (5 patients), being considerably lower in the repair sub-cohort (1.9 vs 12.5%). The estimated survival rate at 5 and 10 years was 80.0 ± 4.5 and 69.1 ± 6.7%, respectively. No patient required reoperation on the proximal aorta and/or aortic valve during the follow-up time and there were only two valve-related events (both embolic, one in each group). Among those patients with repaired valves, the last echocardiography available showed no insufficiency in 40 and an irrelevant insufficiency (1+) in 14. CONCLUSIONS Curative repair of the proximal aorta in acute dissection involving the root provides favourable operative and long-term outcome with very low risk of aortic complications and/or reoperations, regardless if a valve-sparing procedure or replacement with a valve conduit is used. Valve-sparing surgery is frequently suitable, providing excellent outcome and very high durability. PMID:26848190
Furutachi, Akira; Furukawa, Kojiro; Shimauchi, Kouta; Yunoki, Junji; Itoh, Manabu; Takamatsu, Masanori; Nogami, Eijiro; Mukae, Yosuke; Nishida, Takahiro
2018-06-06
We report a case of a 66-year-old man who was diagnosed with severe aortic regurgitation, moderate tricuspid regurgitation and chronic atrial fibrillation. Preoperative computed tomography showed left lung agenesis. We performed aortic valve replacement, tricuspid valve annuloplasty and right pulmonary vein isolation via a left thoracotomy. This approach provided an adequate field of view.
... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...
... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...
Aortic valve replacement with the Biocor PSB stentless xenograft.
Bertolini, P; Luciani, G B; Vecchi, B; Pugliese, P; Mazzucco, A
1998-08-01
The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and quality of life satisfactory.
Tricuspid valve replacement with mechanical prostheses: Short and long-term outcomes.
Rossello, Xavier; Muñoz-Guijosa, Christian; Mena, Elisabet; Camprecios, Marta; Mendez, Ana B; Borras, Xavier; Padro, Josep M
2017-09-01
Tricuspid valve replacement has been associated with high mortality and poor long-term outcomes. We report the preoperative risk factors associated with short and long-term outcomes following tricuspid valve replacement with mechanical prostheses. In 62 patients who underwent mechanical tricuspid valve replacement, clinical, laboratory, and echocardiographic findings were analyzed using both univariate and multivariate analyses to describe operative and long-term mortality. In our population (mean age 59 ± 9.7 years, 82.3% female), most common causes of tricuspid valve disease were rheumatic fever (69.4%) and functional regurgitation (19.4%). Operative and long-term mortality were 17.7 and 33.9%, respectively. Age, diabetes mellitus, and coronary artery disease were independently associated with increased long-term mortality. New York Heart Association (NYHA) class and right heart failure symptoms significantly improved during follow-up. In this series of mechanical tricuspid valve replacements in patients with predominately rheumatic heart disease, operative and long-term mortality were increased; however, survivors had significant improvement in their NYHA class and freedom from right heart failure symptoms. Three preoperative factors (age, diabetes mellitus, and coronary artery disease) were independently associated with long-term mortality. © 2017 Wiley Periodicals, Inc.
Anesthetic Considerations for Transcatheter Pulmonary Valve Replacement.
Gregory, Stephen H; Zoller, Jonathan K; Shahanavaz, Shabana; Chilson, Kelly L; Ridley, Clare H
2018-02-01
The introduction of transcatheter therapy for valvular heart disease has revolutionized the care of patients with valvular disorders. Pathologic regurgitation or stenosis of the pulmonary valve, right ventricular outflow tract, or a right ventricle-to-pulmonary artery conduit represent emerging indications for transcatheter therapy. To date, minimal literature exists detailing the anesthetic management of patients undergoing transcatheter pulmonary valve replacement. In this review, the pathophysiology and indications for transcatheter pulmonary valve replacement and possible complications unique to this procedure are reviewed. Anesthetic management, including preoperative assessment, intraoperative considerations, and early postoperative monitoring, are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.
Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement
NASA Technical Reports Server (NTRS)
Sitges, M.; Kapadia, S.; Rubin, D. N.; Thomas, J. D.; Tuzcu, M. E.; Lever, H. M.
2001-01-01
When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.
2017-11-28
Patients Waiting for Elective Isolated Coronary Artery Bypass Grafting (CABG); Patients Waiting for Aortic Valve Repair/Replacement for Moderate Aortic Stenosis or Severe Regurgitation; Patients Waiting for Mitral Valve Repair/Replacement for Moderate Stenosis or Severe Regurgitation; Patients Waiting for Combined Procedures. (CAGB and Valve)
Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve
VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L
2017-01-01
The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780
Hinderer, Svenja; Brauchle, Eva
2015-01-01
Current clinically applicable tissue and organ replacement therapies are limited in the field of cardiovascular regenerative medicine. The available options do not regenerate damaged tissues and organs, and, in the majority of the cases, show insufficient restoration of tissue function. To date, anticoagulant drug‐free heart valve replacements or growing valves for pediatric patients, hemocompatible and thrombus‐free vascular substitutes that are smaller than 6 mm, and stem cell‐recruiting delivery systems that induce myocardial regeneration are still only visions of researchers and medical professionals worldwide and far from being the standard of clinical treatment. The design of functional off‐the‐shelf biomaterials as well as automatable and up‐scalable biomaterial processing methods are the focus of current research endeavors and of great interest for fields of tissue engineering and regenerative medicine. Here, various approaches that aim to overcome the current limitations are reviewed, focusing on biomaterials design and generation methods for myocardium, heart valves, and blood vessels. Furthermore, novel contact‐ and marker‐free biomaterial and extracellular matrix assessment methods are highlighted. PMID:25778713
Durmaz, Tahir; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin
2014-01-01
Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement. PMID:25120396
Tramarin, Roberto; Pistuddi, Valeria; Maresca, Luigi; Pavesi, Marco; Castelvecchio, Serenella; Menicanti, Lorenzo; de Vincentiis, Carlo; Ranucci, Marco
2017-05-01
Background Anaemia and iron deficiency are frequent following major surgery. The present study aims to identify the iron deficiency patterns in cardiac surgery patients at their admission to a cardiac rehabilitation programme, and to determine which perioperative risk factor(s) may be associated with functional and absolute iron deficiency. Design This was a retrospective study on prospectively collected data. Methods The patient population included 339 patients. Functional iron deficiency was defined in the presence of transferrin saturation <20% and serum ferritin ≥100 µg/l. Absolute iron deficiency was defined in the presence of serum ferritin values <100 µg/l. Results Functional iron deficiency was found in 62.9% of patients and absolute iron deficiency in 10% of the patients. At a multivariable analysis, absolute iron deficiency was significantly ( p = 0.001) associated with mechanical prosthesis mitral valve replacement (odds ratio 5.4, 95% confidence interval 1.9-15) and tissue valve aortic valve replacement (odds ratio 4.5, 95% confidence interval 1.9-11). In mitral valve surgery, mitral repair carried a significant ( p = 0.013) lower risk of absolute iron deficiency (4.4%) than mitral valve replacement with tissue valves (8.3%) or mechanical prostheses (22.5%). Postoperative outcome did not differ between patients with functional iron deficiency and patients without iron deficiency; patients with absolute iron deficiency had a significantly ( p = 0.017) longer postoperative hospital stay (median 11 days) than patients without iron deficiency (median nine days) or with functional iron deficiency (median eight days). Conclusions Absolute iron deficiency following cardiac surgery is more frequent in heart valve surgery and is associated with a prolonged hospital stay. Routine screening for iron deficiency at admission in the cardiac rehabilitation unit is suggested.
Leaflet escape in a new bileaflet mechanical valve: TRI technologies.
Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino
2003-05-13
Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.
Kawahito, Tomohisa; Egawa, Yoshiyasu; Yoshida, Homare; Shimoe, Yasushi; Onishi, Tatsuya; Miyagi, Yuhichi; Terada, Kazuya; Ohta, Akira
2015-07-01
A 24-day-old boy suddenly developed progressive heart failure and was transported to our hospital. Echocardiography showed massive mitral regurgitation due to chordal rupture. Mitral valve repair was performed at 28 days of life, but postoperative valvular function was not satisfactory. A mechanical valve was implanted in the supra-annular position at 37 days of life. Two months after valve replacement, the mechanical valve was suddenly stuck. Emergent redo valve replacement was performed, but the prosthetic valve became stuck again 2 months after the 3rd operation, despite sufficient anti-coagulation therapy. At the 4th operation (6 months after birth), we implanted a pulmonary autograft in the mitral position instead of another mechanical valve in an emergent operation. The right ventricular outflow tract was reconstructed with a valved conduit. A postoperative catheter examination, which was performed 1 year after the Ross II operation, showed mild mitral stenosis with no regurgitation. Previous reports of Ross II operations in infants are rare and long-term results are unknown. However, we advocate that this procedure should be a rescue operation for mitral valve dysfunction in the early period of infants.
The value of aortic valve replacement in elderly patients: an economic analysis.
Wu, YingXing; Grunkemeier, Gary L; Starr, Albert
2007-03-01
Economists have designed frameworks to measure the economic value of improvements in health and longevity. Heart valve replacement surgery has significantly prolonged life expectancy and quality of life. For the example of aortic valve replacement, what is its economic value according to this framework? From 1961 through 2003, a total of 4617 adult patients underwent aortic valve replacement by one team of cardiac surgeons. These patients were provided with a prospective lifetime follow-up service. As of 2005, observed follow-up was 31,671 patient-years, with a maximum of 41 years. A statistical model was used to generate the future life-years of patients currently alive. The value of life-years proposed by economists was applied to determine the economic value of the additional life given to these patients by aortic valve replacement. The total life-years after aortic valve replacement were 53,323, with a gross value of 14.6 billion dollars. The total expected life-years without surgery were 10,157, with an estimated value of 3.0 billion dollars. Thus the net life-years gained by AVR were 43,166, worth 11.6 billion dollars. Subtracting the 451 million dollars total lifetime cost of surgery, the net value of the life-years gained by AVR was 11.2 billion dollars. The mean net value decreases according to age at surgery but is still worth 600,000 dollars for octogenarians and 200,000 dollars for nonagenarians. According to the economic concept of the value of a statistical life, the return on the investment for aortic valve replacement is enormous for patients of all ages, even very elderly patients.
Thirty-Seven-Year Durability of a Starr-Edwards Aortic Prosthesis
Ozkokeli, Mehmet; Ates, Mehmet; Ekinci, Abdurrahman; Akcar, Murat
2005-01-01
We report the case of a patient who was diagnosed with prosthetic valve endocarditis caused by Staphylococcus aureus. He had undergone aortic valve replacement with a Starr-Edwards prosthesis 37 years earlier. Because of uncontrolled infection despite antibiotic treatment, the patient underwent successful surgical replacement of the prosthetic valve. PMID:15902834
Surgical Approaches to Aortic Valve Replacement and Repair—Insights and Challenges
Ramchandani, Mahesh; Reardon, Michael J
2014-01-01
Since 1960, surgical aortic valve replacement (sAVR) had been the only effective treatment for symptomatic severe aortic stenosis until the recent development of transcatheter aortic valve replacement (TAVR). TAVR has offered an alternative, minimally invasive treatment approach particularly for patients whose age or co-morbidities make them unsuitable for sAVR. The rapid and enthusiastic utilization of this new technique has triggered some speculation about the imminent demise of sAVR. We believe that despite the recent advances in TAVR, surgical approach to aortic valve replacement has continued to develop and will continue to be highly relevant in the future. This article will discuss the recent developments and current approaches for sAVR, and how these approaches will keep pace with catheter-based technologies. PMID:29588775
Acquired discrete subaortic stenosis late after mitral valve replacement.
Mohan, Jagdish C; Shukla, Madhu; Mohan, Vishwas; Sethi, Arvind
2016-09-01
Although acquired left ventricular outflow obstruction has been reported in a variety of conditions, there are scant reports of its occurrence following mitral valve replacement (MVR). This study describes two female patients, who developed severe discrete subaortic stenosis, five years following MVR. In both cases, the mitral valve was replaced by a porcine Carpentier-Edwards 27-mm bioprosthesis with preservation of mitral valve leaflets. The risk of very late left ventricular outflow tract obstruction after bio-prosthetic MVR with preservation of subvalvular apparatus needs to be kept in mind in symptomatic patients. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Quality and Safety in Health Care, Part XXX: Transcatheter Aortic Valve Therapy.
Harolds, Jay A
2017-12-01
Initially, the transcatheter aortic valve replacement procedure was approved only for patients with aortic stenosis that was both severe and symptomatic who either also had too high a risk of aortic valve replacement surgery to have the surgery or who had a high risk for the surgery. Between the years 2012 and 2015, the death rate at 30 days declined from an initial rate of 7.5% to 4.6%. There has also been more use of the transfemoral approach over the years. In 2016, the transcatheter aortic valve replacement was approved for patients with aortic stenosis at intermediate risk of surgery.
Chivasso, Pierpaolo; Bruno, Vito D; Farid, Shakil; Malvindi, Pietro Giorgio; Modi, Amit; Benedetto, Umberto; Ciulli, Franco; Abu-Omar, Yasir; Caputo, Massimo; Angelini, Gianni D; Livesey, Steve; Vohra, Hunaid A
2018-04-01
An increasing number of octogenarians are referred to undergo mitral valve surgery for degenerative disease, and percutaneous approaches are being increasingly used in this subgroup of patients. We sought to determine the survival and its predictors after Mitral Valve Surgery in Octogenarians (MiSO) in a multicenter UK study of high-volume specialized centers. Pooled data from 3 centers were collected retrospectively. To identify the predictors of short-term composite outcome of 30 days mortality, acute kidney injury, and cerebrovascular accident, a multivariable logistic regression model was developed. Multiple Cox regression analysis was performed for late mortality. Kaplan-Meier curves were generated for long-term survival in various subsets of patients. Receiver operating characteristic analysis was done to determine the predictive power of the logistic European System for Cardiac Operative Risk Evaluation. A total of 247 patients were included in the study. The median follow-up was 2.9 years (minimum 0, maximum 14 years). A total of 150 patients (60.7%) underwent mitral valve repair, and 97 patients (39.3%) underwent mitral valve replacement. Apart from redo cardiac surgery (mitral valve repair 6 [4%] vs mitral valve replacement 11 [11.3%], P = .04) and preoperative atrial fibrillation (mitral valve repair 79 [52.6%] vs mitral valve replacement 34 [35.1%], P < .01), there was no significant difference in terms of any other preoperative characteristics between the 2 groups. Patient operative risk, as estimated by logistic European System for Cardiac Operative Risk Evaluation, was lower in the mitral valve repair group (10.2 ± 11.8 vs 13.7 ± 15.2 in mitral valve replacement; P = .07). No difference was found between groups for duration of cardiopulmonary bypass and aortic crossclamp times. The 30-day mortality for the whole cohort was 13.8% (mitral valve repair 4.7% vs mitral valve replacement 18.6%; P < .01). No differences were found in terms of postoperative cerebrovascular accident (2% vs 3.1%; P = .9), acute kidney injury requiring dialysis (6.7% vs 13.4%; P = .12), and superficial or deep sternal wound infection (10% vs 16.5%, P = .17; 2% vs 3.1%, P = .67, respectively). The final multiple regression model for short-term composite outcome included previous cardiac surgery (odds ratio [OR], 4.47; 95% confidence interval [CI], 1.37-17.46; P = .02), intra-aortic balloon pump use (OR, 4.77; 95% CI, 1.67-15.79; P < .01), and mitral valve replacement (OR, 7.7; 95% CI, 4.04-14.9; P < .01). Overall survival for the entire cohort at 1, 5, and 10 years was 82.4%, 63.7%, and 45.5% (mitral valve repair vs mitral valve replacement: 89.9% vs 70.7% at 1 year, 69.6% vs 54% at 5 years, and 51.8% vs 35.5% at 10 years; P = .0005). Cox proportional hazard model results showed mitral valve replacement (hazard ratio, 1.88; 95% CI, 1.22-2.89; P < .01) and intra-aortic balloon pump use (hazard ratio, 2.54; 95% CI, 1.26-5.13; P < .01) to be independent predictor factors affecting long-term survival. Logistic European System for Cardiac Operative Risk Evaluation did not perform well in predicting early mortality (area under the curve, 0.57%). In octogenarians, mitral valve repair for degenerative disease is associated with good survival and remains the gold standard, whereas mitral valve replacement is still associated with significant mortality. Logistic European System for Cardiac Operative Risk Evaluation was unable to predict early mortality in our cohort of patients. Larger international multicenter registries are required to optimize the decision-making process in such a high-risk subgroup. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Rapid pannus formation after few months of obstructing aortic mechanical prosthesis.
Al-Alao, Bassel; Simoniuk, Urszula; Heron, Brian; Parissis, Haralabos
2015-11-01
We report a rare case of a prosthetic aortic valve obstruction due to pannus formation only 3 months following aortic and mitral valve replacement. Fragments of asymmetrical pannus formation affected one of the leaflets of the bi-leaflet mechanical valve; the leaflet appeared immobile due to pannus ingrowth into the mechanical skeleton resulting in encroachment of the leaflet, which in turn became immobile. The patient successfully underwent emergency redo-aortic valve replacement.
Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex
2017-08-03
Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Aortic valve surgery of the 21st century: sutureless AVR versus TAVI.
Costache, Victor S; Moldovan, Horatiu; Arsenescu, Catalina; Costache, Andreea
2018-04-01
Surgical aortic valve replacement (sAVR) has been a safe, effective and time-proven technique and is still the standard of care all over the world for aortic valve treatment. The vast majority of centers perform this procedure by doing a median sternotomy with several disadvantages. While many others specialties went minimally invasive decades ago, in cardiovascular field transcatheter valve implantation was the first minimally invasive valvular procedure that gained rapid worldwide acceptance. Transcatheter valve replacement (TAVR) is now marketed as a procedure that should be performed under local anesthesia, by an interventional cardiologist via trans femoral route with no other healthcare professional invited to the patient selection or case planning. An increasing number of surgeons are promoting minimally invasive aortic valve replacement, which is gaining grounds, especially with the help of the new sutureless valve technology. With these two new technologies emerging, legitimate questions arise and need to be answered - which has the longest durability, lower complication rate and lower overall mortality.
Dysfunction of an On-X Heart Valve by Pannus.
Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria
2016-09-01
A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.
Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C
2018-05-01
Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the treatment of severe aortic stenosis in patients with intermediate surgical risk. There remains moderate-to-high uncertainty surrounding the base-case incremental cost-effectiveness ratio. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Transcatheter Mitral Valve Replacement for Native and Failed Bioprosthetic Mitral Valves
Sarkar, Kunal; Reardon, Michael J.; Little, Stephen H.; Barker, Colin M.; Kleiman, Neal S.
2017-01-01
Transcatheter mitral valve replacement (TMVR) is a novel approach for treatment of severe mitral regurgitation. A number of TMVR devices are currently undergoing feasibility trials using both transseptal and transapical routes for device delivery. Overall experience worldwide is limited to fewer than 200 cases. At present, the 30-day mortality exceeds 30% and is attributable to both patient- and device-related factors. TMVR has been successfully used to treat patients with degenerative mitral stenosis (DMS) as well as failed mitral bioprosthesis and mitral repair using transcatheter mitral valve-in-valve (TMViV)/valve-in-ring (ViR) repair. These patients are currently treated with devices designed for transcatheter aortic valve replacement. Multicenter registries have been initiated to collect outcomes data on patients currently undergoing TMViV/ViR and TMVR for DMS and have confirmed the feasibility of TMVR in these patients. However, the high periprocedural and 30-day event rates underscore the need for further improvements in device design and multicenter randomized studies to delineate the role of these technologies in patients with mitral valve disease. PMID:29743999
Root replacement using stentless valves in the small aortic root: a propensity score analysis.
Kunihara, Takashi; Schmidt, Kathrin; Glombitza, Petra; Dzindzibadze, Vachtang; Lausberg, Henning; Schäfers, Hans-Joachim
2006-10-01
Root replacement using a stentless bioprosthesis may be the optimal approach to avoid patient-prosthesis mismatch in patients with a small aortic root. Primary root replacement, however, is considered to be associated with increased surgical risk. We compared early outcome of full root replacement with a stentless bioprosthesis with that of aortic valve replacement with a stented bioprosthesis using propensity score-matching analysis. Of 231 patients undergoing elective, first-time aortic valve replacement with a small root (< or = 22 mm), 120 patients were selected using propensity score-matching analysis. They underwent either root replacement using a 23-mm stentless bioprosthesis (stentless group, n = 60) or supra-annular aortic valve replacement using a 21-mm stented bioprosthesis (stented group, n = 60). Preoperative characteristics and frequency of concomitant operations were identical. Duration of operation (196 +/- 54 versus 174 +/- 49 minutes), cardiopulmonary bypass (112 +/- 36 versus 91 +/- 33 minutes), and aortic cross-clamping (76 +/- 21 versus 61 +/- 21 minutes) were significantly longer in the stentless group. However, the need for perioperative transfusion and the incidence of postoperative reexploration for bleeding (3% versus 8%) was lower, and ventilation time was shorter. Mean duration of intensive care and hospital stay were also significantly shorter (2.3 +/- 1.7 versus 4.0 +/- 3.9 days, 8.9 +/- 3.1 versus 12.4 +/- 5.7 days). In-hospital mortality was identical (5% each). No independent predictor for in-hospital mortality was identified. Full root replacement using a stentless bioprosthesis does not increase postoperative morbidity or mortality of aortic valve replacement and may be advantageous in patients with a small aortic root.
Late outcome analysis of the Braile Biomédica® pericardial valve in the aortic position
Azeredo, Lisandro Gonçalves; Veronese, Elinthon Tavares; Santiago, José Augusto Duncan; Brandão, Carlos Manuel de Almeida; Pomerantzeff, Pablo Maria Alberto; Jatene, Fabio Biscegli
2014-01-01
Objective Aortic valve replacement with Braile bovine pericardial prosthesis has been routinely done at the Heart Institute of the Universidade de São Paulo Medical School since 2006. The objective of this study is to analyze the results of Braile Biomédica® aortic bioprosthesis in patients with aortic valve disease. Methods We retrospectively evaluated 196 patients with aortic valve disease submitted to aortic valve replacement with Braile Biomédica® bovine pericardial prosthesis, between 2006 and 2010. Mean age was 59.41±16.34 years and 67.3% were male. Before surgery, 73.4% of patients were in NYHA functional class III or IV. Results Hospital mortality was 8.16% (16 patients). Linearized rates of mortality, endocarditis, reintervention, and structural dysfunction were 1.065%, 0.91%, 0.68% and 0.075% patients/year, respectively. Actuarial survival was 90.59±2.56% in 88 months. Freedom from reintervention, endocarditis and structural dysfunction was respectively 91.38±2.79%, 89.84±2.92% and 98.57±0.72% in 88 months. Conclusion The Braile Biomédica® pericardial aortic valve prosthesis demonstrated actuarial survival and durability similar to that described in the literature, but further follow up is required to assess the incidence of prosthetic valve endocarditis and structural dysfunction in the future. PMID:25372903
Arnaoutakis, George J; George, Timothy J; Alejo, Diane E; Merlo, Christian A; Baumgartner, William A; Cameron, Duke E; Shah, Ashish S
2011-09-01
The impact of Society of Thoracic Surgeons predicted mortality risk score on resource use has not been previously studied. We hypothesize that increasing Society of Thoracic Surgeons risk scores in patients undergoing aortic valve replacement are associated with greater hospital charges. Clinical and financial data for patients undergoing aortic valve replacement at The Johns Hopkins Hospital over a 10-year period (January 2000 to December 2009) were reviewed. The current Society of Thoracic Surgeons formula (v2.61) for in-hospital mortality was used for all patients. After stratification into risk quartiles, index admission hospital charges were compared across risk strata with rank-sum and Kruskal-Wallis tests. Linear regression and Spearman's coefficient assessed correlation and goodness of fit. Multivariable analysis assessed relative contributions of individual variables on overall charges. A total of 553 patients underwent aortic valve replacement during the study period. Average predicted mortality was 2.9% (±3.4) and actual mortality was 3.4% for aortic valve replacement. Median charges were greater in the upper quartile of patients undergoing aortic valve replacement (quartiles 1-3, $39,949 [interquartile range, 32,708-51,323] vs quartile 4, $62,301 [interquartile range, 45,952-97,103], P < .01]. On univariate linear regression, there was a positive correlation between Society of Thoracic Surgeons risk score and log-transformed charges (coefficient, 0.06; 95% confidence interval, 0.05-0.07; P < .01). Spearman's correlation R-value was 0.51. This positive correlation persisted in risk-adjusted multivariable linear regression. Each 1% increase in Society of Thoracic Surgeons risk score was associated with an added $3000 in hospital charges. This is the first study to show that increasing Society of Thoracic Surgeons risk score predicts greater charges after aortic valve replacement. As competing therapies, such as percutaneous valve replacement, emerge to treat high-risk patients, these results serve as a benchmark to compare resource use. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Linke, Axel; Walther, Thomas; Schuler, Gerhard
2010-03-01
Treatment of aortic stenosis remains challenging in older individuals, as their perioperative mortality for open heart surgery is increased due to comorbidities. Transcatheter aortic valve implantation using the CoreValve ReValving System (Medtronic, Minneapolis, USA) and the Edwards SAPIEN transcatheter heart valve (THV; Edwards Lifescience, Irvine, California, USA) represents an alternative to conventional valve replacement in elderly patients that have a high risk for conventional surgery. This article summarizes the evidence-base from recent clinical trials. The early results of these landmark studies suggest that transcatheter aortic valve implantation with either one of the prosthesis is feasible, safe, improves hemodynamics and, therefore, might be an alternative to conventional aortic valve replacement in very high-risk patients. However, all of the available transcatheter heart valves have certain disadvantages, limiting their use in daily clinical practice. The process of decision making, which valve to use and which access route to choose is illustrated in this article through clinical case scenarios. Additionally, the lessons learned thus far from the European perspective and the potential impact on the future use in the US are discussed. Despite of the progress in this field, we are still lacking an optimal transcatheter heart valve. Once it is available, we can take the plunge to compare transcatheter valve implantation with convention surgery in severe aortic stenosis!
Kohlmann, Sebastian; Rimington, Helen; Weinman, John
2012-06-01
Identification of risk factors for decline in health status by profiling illness perceptions before and one year after heart valve replacement surgery. Prospective data from N=225 consecutively admitted first time valve replacement patients was assessed before and one year after surgery. Patients were asked about their illness perceptions (Illness Perception Questionnaire-Revised) and mood state (Hospital Anxiety and Depression Scale). Health status was defined by quality of life (Short-Form 36) and New York Heart Association (NYHA) class. Cluster analyses were conducted to identify illness perception profiles over time. Predictors of health status after surgery were analyzed with multivariate methods. Patients were grouped according to the stability and nature (positive, negative) of their illness perception profile over one year. One year after surgery patients holding a negative illness perception profile showed a lower physical quality of life and were diagnosed in a higher New York Heart Association class than patients changing to positive and patients with stable positive illness perceptions (P<.001). Over and above biological determinants, post-surgery physical quality of life and NYHA class were both predicted by pre-surgery illness perception profiles (P<.05). Patients going for heart valve replacement surgery can be easily categorized into illness perception profiles that predict health status one year after surgery. These patients could benefit from early screening as negative illness perceptions are modifiable risk factors. Copyright © 2012 Elsevier Inc. All rights reserved.
Aortic valve replacement for aortic stenosis caused by alkaptonuria.
Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru
2013-03-01
We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Xiao, Jian; Yin, Liang; Lin, Yiyun; Zhang, Yufeng; Wu, Lihui; Wang, Zhinong
2016-07-01
Children with infective endocarditis (IE) have to undergo valve replacement instead of valve repair in China due to severe valve damage. The present study is to review our experience on surgical treatment of children with IE in reference to the incidence, pathologic status, diagnosis, surgical strategies and outcomes. We reviewed 35 patients with a mean age of 13.7±2.2 years who were underwent valve replacement surgery for IE during the period from January 1993 to December 2013. Preoperative transthoracic echocardiographic (TTE) evaluation and transesophageal echocardiography during operation were performed in all patients. All the children underwent chart review and retrospective risk-hazard analysis. Among the patients surveyed congenital cardiac lesions were present in 15 (42.8%), rheumatic heart valve disease in 2 (5.7%) and previous heart surgery in 2 (5.7%). The median stay of intensive care unit was 6 days. Intraoperative findings showed that the endocarditis involved mostly the mitral and aortic valves (88.5%). Triple or quadruple valve involvement was found in one patient each. Ten-year freedom from IE-related death and re-intervention was 94.2% and 91.6%, respectively. Children undergoing surgery for IE frequently have advanced disease with embolic complications. Although valve replacement is not the primary option for pediatric IE, the rate of 5-year survival and freedom from re-operation was optimal prognostically. Pediatric physicians should pay attention to the common clinical features of IE so that the native valve is preserved well.
Martin, Jacob A.; Mayhew, Christopher R.; Morris, Amanda J.; Bader, Angela M.; Tsai, Mitchell H.; Urman, Richard D.
2018-01-01
Background Time-driven activity-based costing (TDABC) is a methodology that calculates the costs of healthcare resources consumed as a patient moves along a care process. Limited data exist on the application of TDABC from the perspective of an anesthesia provider. We describe the use of TDABC, a bottom-up costing strategy and financial outcomes for three different medical-surgical procedures. Methods In each case, a multi-disciplinary team created process maps describing the care delivery cycle for a patient encounter using the TDABC methodology. Each step in a process map delineated an activity required for delivery of patient care. The resources (personnel, equipment and supplies) associated with each step were identified. A per minute cost for each resource expended was generated, known as the capacity cost rate, and multiplied by its time requirement. The total cost for an episode of care was obtained by adding the cost of each individual resource consumed as the patient moved along a clinical pathway. Results We built process maps for colonoscopy in the gastroenterology suite, calculated costs of an aortic valve replacement by comparing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR) techniques, and determined the cost of carpal tunnel release in an operating room versus an ambulatory procedure room. Conclusions TDABC is central to the value-based healthcare platform. Application of TDABC provides a framework to identify process improvements for health care delivery. The first case demonstrates cost-savings and improved wait times by shifting some of the colonoscopies scheduled with an anesthesiologist from the main hospital to the ambulatory facility. In the second case, we show that the deployment of an aortic valve via the transcatheter route front loads the costs compared to traditional, surgical replacement. The last case demonstrates significant cost savings to the healthcare system associated with re-organization of staff required to execute a carpal tunnel release. PMID:29511420
[Ministernotomy: a preliminary experience in heart valve surgery].
Kovarević, Pavle; Mihajlović, Bogoljub; Velicki, Lazar; Redzek, Aleksandar; Ivanović, Vladimir; Komazec, Nikola
2011-05-01
The last decade of the 20th century brought up a significant development in the field of minimally invasive approaches to the valvular heart surgery. Potential benefits of this method are: good esthetic appearance, reduced pain, reduction of postoperative hemorrhage and incidence of surgical site infection, shorter postoperative intensive care units (ICU) period and overall in-hospital period. Partial upper median stemotomy currently presents as a state-of-the art method for minimally invasive surgery of cardiac valves. The aim of this study was to report on initial experience in application of this surgical method in the surgery of mitral and aortic valves. The study was designed and conducted in a prospective manner and included all the patients who underwent minimally invasive cardiac valve surgery through the partial upper median stemotomy during the period November 2008 - August 2009. We analyzed the data on mean age of patients, mean extubation time, mean postoperative drainage, mean duration of hospital stay, as well as on occurance of postoperative complications (postoperative bleeding, surgical site infection and cerebrovascular insult). During the observed period, in the Institute for Cardiovascular Diseases of Vojvodina, Clinic for Cardiovascular Surgery, 17 ministernotomies were performed, with 14 aortic valve replacements (82.35%) and 3 mitral valve replacements (17.65%). Mean age of the patients was 60.78 +/- 12.99 years (64.71% males, 35.29% females). Mean extubation time was 12.53 +/- 8.87 hours with 23.5% of the patients extubated in less than 8 hours. Mean duration of hospital stay was 12.35 +/- 10.17 days (in 29.4% of the patients less than 8 days). Mean postoperative drainage was 547.06 +/- 335.2 mL. Postoperative complications included: bleeding (5.88%) and cerebrovascular insult (5.88%). One patient (5.88%) required conversion to full stemotomy. Partial upper median sternotomy represents the optimal surgical method for the interventions on the whole ascendant aorta (including aortic valve) and mitral valve through the roof of the left atrium, with a few significant advantages compared to the full stemotomy surgical approach.
Bardakci, Hasmet; Altıntaş, Garip; Çiçek, Omer Faruk; Kervan, Umit; Yilmaz, Sevinc; Kaplan, Sadi; Birincioglu, Cemal Levent
2013-05-01
To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.
Lou, Junyang; Obuchowski, Nancy A; Krishnaswamy, Amar; Popovic, Zoran; Flamm, Scott D; Kapadia, Samir R; Svensson, Lars G; Bolen, Michael A; Desai, Milind Y; Halliburton, Sandra S; Tuzcu, E Murat; Schoenhagen, Paul
2015-01-01
Preprocedural 3-dimensional CT imaging of the aortic annular plane plays a critical role for transcatheter aortic valve replacement (TAVR) planning; however, manual reconstructions are complex. Automated analysis software may improve reproducibility and agreement between readers but is incompletely validated. In 110 TAVR patients (mean age, 81 years; 37% female) undergoing preprocedural multidetector CT, automated reconstruction of the aortic annular plane and planimetry of the annulus was performed with a prototype of now commercially available software (syngo.CT Cardiac Function-Valve Pilot; Siemens Healthcare, Erlangen, Germany). Fully automated, semiautomated, and manual annulus measurements were compared. Intrareader and inter-reader agreement, intermodality agreement, and interchangeability were analyzed. Finally, the impact of these measurements on recommended valve size was evaluated. Semiautomated analysis required major correction in 5 patients (4.5%). In the remaining 95.5%, only minor correction was performed. Mean manual annulus area was significantly smaller than fully automated results (P < .001 for both readers) but similar to semiautomated measurements (5.0 vs 5.4 vs 4.9 cm(2), respectively). The frequency of concordant recommendations for valve size increased if manual analysis was replaced with the semiautomated method (60% agreement was improved to 82.4%; 95% confidence interval for the difference [69.1%-83.4%]). Semiautomated aortic annulus analysis, with minor correction by the user, provides reliable results in the context of TAVR annulus evaluation. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Optimal surgical management of severe tricuspid regurgitation in cardiac transplant patients.
Filsoufi, Farzan; Salzberg, Sacha P; Anderson, Curtis A; Couper, Gregory S; Cohn, Lawrence H; Adams, David H
2006-03-01
Severe tricuspid regurgitation (TR) with signs of right-sided heart failure is rare after orthotopic heart transplantation (OHT). In some instances, this condition will require surgical correction using reconstructive surgery or prosthetic valve replacement. Repair techniques of atrioventricular valves are now well described. However, the results of the different surgical procedures in this setting have not been widely reported and may depend on the type of valvular dysfunction and lesions present. Herein we report our experience in a group of patients requiring surgical correction of symptomatic severe TR after OHT. We reviewed our transplant experience during the period from July 1992 to July 1999 (n = 138 cardiac transplants). Eight patients (5.8%) developed symptomatic severe TR requiring surgical correction after a mean duration of 21 months after OHT. Patients were divided into 2 groups based on the mechanism of regurgitation using Carpentier's functional classification. In Group 1 (n = 4), the mechanism of tricuspid regurgitation was Carpentier's Type I, secondary to annular dilation. In Group 2 (n = 4) the mechanism of TR was leaflet prolapse (Type II), due to chordal rupture after biopsy injury. Initially, tricuspid valve integrity was surgically restored in all 8 patients with either valve repair (n = 6) or replacement (n = 2). In Group 1, 2 patients underwent valve repair using a ring annuloplasty and 2 patients underwent valve replacement with a bioprosthetic valve (n = 1) or pulmonary allograft (n = 1). In Group 2, all patients underwent valve repair using a variety of techniques in combination with tricuspid annuloplasty. During the follow-up period, 3 of the 6 (50%) primary repairs (1 patient in Group 1 and 2 in Group 2) failed and required replacement with a bioprosthesis at 8 days, 14 days and 4 years, respectively. The pulmonary allograft failed secondary to valvular stenosis and was replaced with a bioprosthesis after 10 months. Overall, no failures occurred in any of the 5 bioprosthetic valves placed at the primary operation (n = 1) or after failed tricuspid repair/pulmonary allograft (n = 4), after a mean follow-up of 55 months. TR requiring surgical correction after OHT is a rare condition and requires a tailored surgical strategy. This strategy should take into account the mechanism of valve dysfunction and specific valvular lesions. In patients with Type I dysfunction secondary to annular dilation, valve repair with a remodeling annuloplasty should be performed; however, in the presence of any residual TR on transesophageal echocardiography (TEE) at the completion of cardiopulmonary bypass (CPB), a valve replacement with a bioprosthesis is warranted during the same procedure. In patients with Type II dysfunction with leaflet prolapse and biopsy-induced chordal injury, a bioprosthetic valve replacement seems a reliable surgical option.
Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper; Jensen, Maiken Brit; Lund, Jens Teglgaard; Pedersen, Mads Møller; Lange, Theis; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann
2016-10-01
Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angle-independent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p < 0.0001), induced systolic backflow (p < 0.003) and reduced systolic jet width (p < 0.0001). After valve replacement, the systolic backflow and jet width were normalized (p < 0.52 and p < 0.22), but flow complexity was not (p < 0.0001). Flow complexity (p < 0.0001), systolic jet width (p < 0.0001) and systolic backflow (p < 0.001) were associated with peak systolic velocity. The study found that aortic stenosis changes blood flow in the ascending aorta and valve replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Behr, Luc; Chetboul, Valérie; Sampedrano, Carolina Carlos; Vassiliki, Gouni; Pouchelon, Jean-Louis; Laborde, François; Borenstein, Nicolas
2007-04-01
To describe an open, beating heart surgical technique and use of a bovine pericardial prosthetic valve for mitral valve replacement (MVR) in the dog. Clinical case report. Male Bull Terrier (17-month-old, 26 kg) with mitral valve dysplasia and severe regurgitation. A bovine pericardial bioprosthesis was used to replace the mitral valve using an open beating heart surgical technique and cardiopulmonary bypass. Successful MVR was achieved using a beating heart technique. Mitral regurgitation resolved and cardiac performances improved (left ventricular end-diastolic diameter decreased from 57.6 to 48.7 mm, and left atrium/aorta ratio returned to almost normal, from 1.62 to 1.19). Cardiopulmonary by-pass time and total surgical duration were decreased compared with standard cardioplegic techniques. Surgical recovery was uneventful and on echocardiography 6 months later valve function was excellent. Considering the technique advantages (no cardiac arrest, ischemic reperfusion injury, and hypothermia, or the need for aortic dissection and cannulation for administration of cardioplegic solution), short-term mortality and morbidity may be reduced compared with standard cardioplegic techniques. Based on experience in this dog, beating heart mitral valvular replacement is a seemingly safe and viable option for the dog and bovine pericardial prosthesis may provide better long-term survival than mechanical prostheses.
Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K.; Goncalves, Alexandra; Di Carli, Marcelo F.; Rybicki, Frank J.; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron
2017-01-01
Background 3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. Objective To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). Methods This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Results Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of −0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Conclusions Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. PMID:26732862
Reoperations after tricuspid valve repair: re-repair versus replacement
Hwang, Ho Young; Kim, Kyung-Hwan; Kim, Ki-Bong
2016-01-01
Background Data demonstrating results of reoperation after initial tricuspid valve repair are scarce. We evaluated outcomes of tricuspid reoperations after tricuspid valve repair and compared the results of tricuspid re-repair with those of tricuspid valve replacement (TVR). Methods From 1994 to 2012, 53 patients (56±15 years, male:female =14:39) underwent tricuspid reoperations due to recurrent tricuspid regurgitation (TR) after initial repair. Twenty-two patients underwent tricuspid re-repair (TAP group) and 31 patients underwent TVR (TVR group). Results Early mortality occurred in 6 patients (11%). Early mortality and incidence of postoperative complications were similar between the 2 groups. There were 14 cases of late mortality including 9 cardiac deaths. Five- and 10-year free from cardiac death rates were 82% and 67%, respectively, without any intergroup difference. Recurrent TR (> moderate) developed in 6 TAP group patients and structural valve deterioration occurred in 1 TVR group patient (P=0.002). Isolated tricuspid valve surgery (P=0.044) and presence of atrial fibrillation during the follow-up (P=0.051) were associated with recurrent TR after re-repair. However, the overall tricuspid valve-related event rates were similar between the 2 groups with 5- and 10-year rates of 61% and 41%, respectively. Conclusions Tricuspid valve reoperation after initial repair resulted in high rates of operative mortality and complications. Long-term event-free rate was similar regardless of the type of surgery. However, great care might be needed when performing re-repair in patients with atrial fibrillation and those who had isolated tricuspid valve disease due to high recurrence of TR after re-repair. PMID:26904221
Transcatheter aortic-valve replacement with a self-expanding prosthesis.
Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K
2014-05-08
We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fetterly, K; Mathew, V
Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of themore » aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.« less
Blot, William J; Ibrahim, Michel A; Ivey, Tom D; Acheson, Donald E; Brookmeyer, Ron; Weyman, Arthur; Defauw, Joseph; Smith, J Kermit; Harrison, Donald
2005-05-31
The first Björk-Shiley convexoconcave (BSCC) prosthetic heart valves were implanted in 1978. The 25th anniversary provided a stimulus to summarize the research data relevant to BSCC valve fracture, patient management, and current clinical options. Published and unpublished data on the risks of BSCC valve fracture and replacement were compiled, and strategies for identifying candidates for prophylactic valve reoperation were summarized. By December 2003, outlet strut fractures (OSFs), often with fatal outcomes, had been reported in 633 BSCC valves (0.7% of 86,000 valves implanted). Fractures still continue to occur, but average rates of OSFs in 60 degrees valves are now <0.1% per year. OSF risk varies markedly by valve characteristics, especially valve angle and size, with weaker effects associated with other manufacturing variables. OSF risks are mildly lower among women than men but decline sharply with advancing age. The risks of valve replacement typically greatly exceed those of OSF. By comparing individualized estimated risks of OSF versus valve replacement, guidelines have been developed to identify the small percentage of BSCC patients (mostly younger men) who would be expected to have a gain in life expectancy should reoperative surgery be performed. Twenty-five years after the initial BSCC valve implants, fractures continue to occur. Continued monitoring of BSCC patients is needed to track and quantify risks and enable periodic updating of guidelines for patients and their physicians.
Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T
2017-04-01
A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures.
Chamandi, Chekrallah; Puri, Rishi; Rodriguez-Gabella, Tania; Rodés-Cabau, Josep
2017-09-01
Transcatheter aortic valve replacement (TAVR) is a well-established treatment for patients with severe symptomatic aortic stenosis who are at high or prohibitive surgical risk. More recently, TAVR has emerged as a valid alternative to surgical aortic valve replacement for treating intermediate-risk patients, and several studies are currently evaluating the role of TAVR in low-risk patients. Transcatheter heart valve (THV) technologies have evolved considerably over time, and important iterations have been implemented in many of the latest-generation devices to (1) reduce the size and improve delivery system properties; (2) improve valve deployment, repositioning, and retrievability; and (3) reduce paravalvular leaks. This article reviews the main characteristics of, and clinical results associated with, the newer-generation THVs while providing an overview of novel TAVR indications. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Aortic valve replacement for Libman-Sacks endocarditis
Keenan, Jack B; Janardhanan, Rajesh; Larsen, Brandon T; Khalpey, Zain
2016-01-01
A 24-year-old man with systemic lupus erythematosus and antiphospholipid syndrome complicated by lupus nephritis presented with acute limb ischaemia secondary to an embolus. Following embolectomy, the patient underwent a transthoracic echocardiogram which revealed a large vegetation on all three cusps of the aortic valve. The patient was taken for an urgent aortic valve replacement with a mechanical valve. Cultures of one cusp remained sterile. Histopathological examination of the remaining two cusps revealed sterile fibrin-rich thrombotic vegetations characteristic of non-bacterial thrombotic endocarditis. PMID:27702929
van Gils, Lennart; Tchetche, Didier; Lhermusier, Thibault; Abawi, Masieh; Dumonteil, Nicolas; Rodriguez Olivares, Ramón; Molina-Martin de Nicolas, Javier; Stella, Pieter R; Carrié, Didier; De Jaegere, Peter P; Van Mieghem, Nicolas M
2017-03-03
Right bundle branch block is an established predictor for new conduction disturbances and need for a permanent pacemaker (PPM) after transcatheter aortic valve replacement. The aim of the study was to evaluate the absolute rates of transcatheter aortic valve replacement related PPM implantations in patients with pre-existent right bundle branch block and categorize for different transcatheter heart valves. We pooled data on 306 transcatheter aortic valve replacement patients from 4 high-volume centers in Europe and selected those with right bundle branch block at baseline without a previously implanted PPM. Logistic regression was used to evaluate whether PPM rate differed among transcatheter heart valves after adjustment for confounders. Mean age was 83±7 years and 63% were male. Median Society of Thoracic Surgeons score was 6.3 (interquartile range, 4.1-10.2). The following transcatheter valve designs were used: Medtronic CoreValve (n=130; Medtronic, Minneapolis, MN); Edwards Sapien XT (ES-XT; n=124) and Edwards Sapien 3 (ES-3; n=32; Edwards Lifesciences, Irvine, CA); and Boston Scientific Lotus (n=20; Boston Scientific Corporation, Marlborough, MA). Overall permanent pacemaker implantation rate post-transcatheter aortic valve replacement was 41%, and per valve design: 75% with Lotus, 46% with CoreValve, 32% with ES-XT, and 34% with ES-3. The indication for PPM implantation was total atrioventricular block in 98% of the cases. Lotus was associated with a higher PPM rate than all other valves. PPM rate did not differ between ES-XT and ES-3. Ventricular paced rhythm at 30-day and 1-year follow-up was present in 81% at 89%, respectively. Right bundle branch block at baseline is associated with a high incidence of PPM implantation for all transcatheter heart valves. PPM rate was highest for Lotus and lowest for ES-XT and ES-3. Pacemaker dependency remained high during follow-up. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Performance of stented biological valves for right ventricular outflow tract reconstruction.
Buchholz, Christian; Mayr, Andreas; Purbojo, Ariawan; Glöckler, Martin; Toka, Okan; Cesnjevar, Robert A; Rüffer, André
2016-12-01
This retrospective single-centre review presents mid- and long-term results of stented biological valves (SBVs) in the pulmonary position. Fifty-two SBVs (17 Carpentier-Edwards Supraannular; 13 Carpentier-Edwards Perimount; 12 St. Jude Medical Trifecta; 4 Sorin Mitroflow; 4 Sorin Soprano; 2 Sorin More) were implanted between 2000 and 2015. The median valve size, patient age and weight were 23 mm (range 19-27), 22.8 years (range 5-77) and 62.0 kg (range 14-110), respectively. The main cardiac diagnosis was tetralogy of Fallot in 26 patients (50%). Forty-four patients (85%) had previous cardiac surgery; 12 patients (23%) had previous conduit or biological valve replacement. Valve degeneration was defined as a valvular peak pressure gradient >50 mmHg or pulmonary valve regurgitation more than moderate. The mean follow-up was 7.9 ± 5.5 years. Two patients died after 5.8 and 6.1 years of causes not related to SBVs. Eleven SBVs (21%) had to be replaced surgically (n = 6) or interventionally (n = 5) after 9.0 ± 4.1 years due to valve degeneration (n = 8), endocarditis (n = 2) or right ventricular dysfunction (n = 1). The rates of freedom from valve replacement were 100%, 92% [95% confidence interval (CI) 79-97], 81% (CI 64-91) and 60% (CI 40-78) after 1, 5, 10 and 15 years, respectively. Successful interventional valve-in-valve implantation resulted in 100% freedom from surgical valve replacement in all patients older than 19.1 years. Multivariate analysis identified patient age <19.1 years (P = 0.007) as a risk factor for earlier valve degeneration. SBVs in the pulmonary position showed encouraging long-term results in mature patients. The design of SBVs enables interventional valve implantation, postponing the need for reoperation. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Boudoulas, Konstantinos Dean; Ravi, Yazhini; Garcia, Daniel; Saini, Uksha; Sofowora, Gbemiga G.; Gumina, Richard J.; Sai-Sudhakar, Chittoor B.
2013-01-01
Aim: While the incidence of rheumatic heart disease has declined dramatically over the last half-century, the number of valve surgeries has not changed. This study was undertaken to define the most common type of valvular heart disease requiring surgery today, and determine in-hospital surgical mortality and length-of-stay (LOS) for isolated aortic or mitral valve surgery in a United States tertiary-care hospital. Methods: Patients with valve surgery between January 2002 to June 2008 at The Ohio State University Medical Center were studied. Patients only with isolated aortic or mitral valve surgery were analyzed. Results: From 915 patients undergoing at least aortic or mitral valve surgery, the majority had concomitant cardiac proce-dures mostly coronary artery bypass grafting (CABG); only 340 patients had isolated aortic (n=204) or mitral (n=136) valve surgery. In-hospital surgical mortality for mitral regurgitation (n=119), aortic stenosis (n=151), aortic insufficiency (n=53) and mitral stenosis (n=17) was 2.5% (replacement 3.4%; repair 1.6%), 3.9%, 5.6% and 5.8%, respectively (p=NS). Median LOS for aortic insufficiency, aortic stenosis, mitral regurgitation, and mitral stenosis was 7, 8, 9 (replacement 11.5; repair 7) and 11 days, respectively (p<0.05 for group). In-hospital surgical mortality for single valve surgery plus CABG was 10.2% (p<0.005 compared to single valve surgery). Conclusions: Aortic stenosis and mitral regurgitation are the most common valvular lesions requiring surgery today. Surgery for isolated aortic or mitral valve disease has low in-hospital mortality with modest LOS. Concomitant CABG with valve surgery increases mortality substantially. Hospital analysis is needed to monitor quality and stimulate improvement among Institutions. PMID:24339838
Peñalver, Jorge; Shatila, Wassim; Silva, Guilherme V
2017-04-01
Surgical valve replacement after infective endocarditis can result in local destructive paravalvular lesions. A 30-year-old woman with infective endocarditis underwent mitral valve replacement that was complicated postoperatively by 2 paravalvular leaks. During percutaneous closure of the leaks, a Gerbode defect was also found and closed. We discuss our patient's case and its relation to others in the relevant medical literature. To our knowledge, we are the first to describe the use of a percutaneous approach to close concomitant paravalvular leaks and a Gerbode defect.
Aortic valve ochronosis: a rare manifestation of alkaptonuria
Steger, Christina Maria
2011-01-01
Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed. PMID:22689837
Aortic valve ochronosis: a rare manifestation of alkaptonuria.
Steger, Christina Maria
2011-07-28
Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.
Aortic valve repair leads to a low incidence of valve-related complications.
Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim
2010-01-01
Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Hinderer, Svenja; Brauchle, Eva; Schenke-Layland, Katja
2015-11-18
Current clinically applicable tissue and organ replacement therapies are limited in the field of cardiovascular regenerative medicine. The available options do not regenerate damaged tissues and organs, and, in the majority of the cases, show insufficient restoration of tissue function. To date, anticoagulant drug-free heart valve replacements or growing valves for pediatric patients, hemocompatible and thrombus-free vascular substitutes that are smaller than 6 mm, and stem cell-recruiting delivery systems that induce myocardial regeneration are still only visions of researchers and medical professionals worldwide and far from being the standard of clinical treatment. The design of functional off-the-shelf biomaterials as well as automatable and up-scalable biomaterial processing methods are the focus of current research endeavors and of great interest for fields of tissue engineering and regenerative medicine. Here, various approaches that aim to overcome the current limitations are reviewed, focusing on biomaterials design and generation methods for myocardium, heart valves, and blood vessels. Furthermore, novel contact- and marker-free biomaterial and extracellular matrix assessment methods are highlighted. © 2015 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Elasfar, Abdelfatah
2012-01-01
Elevated plasma brain natriuretic peptide (BNP) levels have been demonstrated in patients with chronic valvular disease. We designed the present study to assess whether changes in N-terminal pro-brain natriuretic peptide (NT-proBNP) levels after mitral, aortic and double mitral and aortic valve replacement reflect changes in heart failure (HF) symptoms including New York Heart Association (NYHA) class and changes in left atrium (LA) size, left ventricle (LV) size and LV function. A prospective observational nonrandomized study among consecutive patients undergoing mitral and/or aortic valve replacement in our center. The study population consisted of 24 patients (mean [SD] age of 55.3 [16.2] years, 58% were males) who underwent surgical mitral valve replacement (12 patients), aortic valve replacement (8 patients) and combined mitral and aortic valve replacement (4 patients). NT-proBNP measurements, transthoracic echocardiography and NYHA class assessments were performed before and 6 months after surgery. The decrease in NT-proBNP was associated with decrease in left atrial dimension (r = 0.73, P < .002), LV end-diastolic dimension (r=0.65, P=.001), LV end-systolic dimension (r=0.53, P=.036), and increase in ejection fraction (r=-0.65, P=.001) after 6 months postoperatively. Furthermore, a decreasing NT-proBNP was associated with improvement in NYHA class. NT-proBNP levels after mitral, aortic and double valve replacement correlates with changes in HF manifestations as well as changes in LA size and LV dimension and function. Thus, we hypothesize that interval measurement of the NT-proBNP level at clinic visits can allow early detection of any clinical deterioration as well as the possibility of assessment of the long-term outcome of those patients.
Culler, Steven D; Cohen, David J; Brown, Phillip P; Kugelmass, Aaron D; Reynolds, Matthew R; Ambrose, Karen; Schlosser, Michael L; Simon, April W; Katz, Marc R
2018-04-01
This study reports trends in volume and adverse events associated with isolated aortic valve procedures performed in Medicare beneficiaries between 2009 and 2015. This retrospective study used the annual fiscal year Medicare Provider Analysis and Review file to identify all Medicare beneficiaries undergoing an isolated aortic valve procedure. Outcome measures included three mortality rates and nine in-hospital adverse events. The final study population consisted of 233,660 hospitalizations. During the study period, Medicare beneficiaries undergoing an aortic valve procedure increased from 22,076 to 49,362, for an average annual growth rate of 14.45%. Transcatheter aortic valve replacement (TAVR) procedures per 100,000 Medicare beneficiaries grew from 10.7 in 2012 to 41.1 in 2015. Overall, in-hospital mortality rates, cumulative 30-day mortality rates, and 90-day postdischarge mortality rates declined annually during the study period. However, the 90-day mortality rate for TAVR was nearly double the rate for the tissue surgical aortic valve replacement group. Nearly 68% of Medicare beneficiaries experienced at least one in-hospital adverse event during their index hospitalization. Medicare beneficiaries undergoing TAVR had the lowest observed adverse events rates among the aortic valve procedures in 2015. The total number of Medicare beneficiaries undergoing isolated aortic valve procedures increased from 47.5 to 88.9 per 100,000 Medicare beneficiaries during the study period. Aortic valve procedures increased significantly during this study period primarily due to the increase in TAVR, with clinical outcomes improving as well. Although long-term outcomes of TAVR are still under investigation, these results are promising. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Pediatric Tubular Pulmonary Heart Valve from Decellularized Engineered Tissue Tubes
Reimer, Jay M.; Syedain, Zeeshan H.; Haynie, Bee H.T.; Tranquillo, Robert T.
2015-01-01
Pediatric patients account for a small portion of the heart valve replacements performed, but a pediatric pulmonary valve replacement with growth potential remains an unmet clinical need. Herein we report the first tubular heart valve made from two decellularized, engineered tissue tubes attached with absorbable sutures, which can meet this need, in principle. Engineered tissue tubes were fabricated by allowing ovine dermal fibroblasts to replace a sacrificial fibrin gel with an aligned, cell-produced collagenous matrix, which was subsequently decellularized. Previously, these engineered tubes became extensively recellularized following implantation into the sheep femoral artery. Thus, a tubular valve made from these tubes may be amenable to recellularization and, ideally, somatic growth. The suture line pattern generated three equi-spaced “leaflets” in the inner tube, which collapsed inward when exposed to back pressure, per tubular valve design. Valve testing was performed in a pulse duplicator system equipped with a secondary flow loop to allow for root distention. All tissue-engineered valves exhibited full leaflet opening and closing, minimal regurgitation (< 5%), and low systolic pressure gradients (< 2.5 mmHg) under pulmonary conditions. Valve performance was maintained under various trans-root pressure gradients and no tissue damage was evident after 2 million cycles of fatigue testing. PMID:26036175
Sakamoto, Kosuke; Totsugawa, Toshinori; Hiraoka, Arudo; Tamura, Kentaro; Yoshitaka, Hidenori; Sakaguchi, Taichi
2018-05-30
An 88-year-old woman was diagnosed with aortic stenosis and an aortic annulus that was too narrow to perform transcatheter aortic valve implantation. Surgery was performed through a 7-cm right mini-thoracotomy at the fourth intercostal space. A 19-mm aortic valve bioprosthesis was implanted after root enlargement. The fourth intercostal space was a suitable site for aortic root enlargement because of the shorter skin-to-root distance and the detailed exposure of the aortic valve after cutting the aortic wall. This study concluded that minimally-invasive aortic valve replacement following root enlargement can be an option for the treatment of elderly patients with aortic stenosis accompanied by an annulus that is too small to perform transcatheter aortic valve implantation.
Guariento, Alvise; Burke, Redmond; Fedrigo, Marny; Angelini, Annalisa; Maschietto, Nicola; Vida, Vladimiro; Thiene, Gaetano; Stellin, Giovanni; Padalino, Massimo
2016-01-01
Valve replacement in children with functionally univentricular hearts remains challenging. The absence of small prostheses, the lack of growth, and the need for anticoagulation limit these procedures. We describe a 1-year follow-up of an extracellular matrix scaffold tube used as systemic atrio-ventricular valve in an infant. Copyright © 2015 Elsevier Inc. All rights reserved.
Dissection of the atrial wall after mitral valve replacement.
Lukács, L; Kassai, I; Lengyel, M
1996-01-01
We describe an unusual sequela of mitral valve replacement in a 50-year-old woman who had undergone a closed mitral commissurotomy in 1975. She was admitted to our hospital because of mitral restenosis in November 1993, at which time her mitral valve was replaced with a mechanical prosthesis. On the 8th postoperative day, the patient developed symptoms of heart failure; transesophageal echocardiography revealed dissection and rupture of the left atrial wall. At prompt reoperation, we found an interlayer dissection and rupture of the atrial wall into the left atrium. We repaired the ruptured atrial wall with a prosthetic patch. The postoperative course was uneventful, and postoperative transesophageal echocardiography showed normal prosthetic valve function and no dissection. Images PMID:8680278
Etz, Christian D; Girrbach, Felix F; von Aspern, Konstantin; Battellini, Roberto; Dohmen, Pascal; Hoyer, Alexandro; Luehr, Maximilian; Misfeld, Martin; Borger, Michael A; Mohr, Friedrich W
2013-09-10
The choice of the best conduit for root/ascending disease and its impact on longevity remain controversial in quinquagenarians. A total of 205 patients (men=155) between 50 and 60 years (mean, 55.7 ± 2.9 years) received either a stentless porcine xenoroot (n=78) or a mechanically valved composite prosthesis (n=127) between February 1998 and July 2011. Of these, 166 patients underwent root replacement for aneurysmal disease (porcine: 39% [n=65]; mechanical: 61% [n=101]; P=0.5), 25 for acute type A aortic dissection (porcine: 32% [n=8]; mechanical: 68% [n=17]; P=0.51), and 14 for endocarditis/iatrogenic injury involving the aortic root (6.4% [n=5] versus 7.1% [n=9]; P=1.0). The predominant aortic valve pathology was stenosis in 19% (n=38), regurgitation in 50% (n=102), combined valvular dysfunction in 26% (n=54), and normal aortic valve function in 5% (n=11). Concomitant procedures included coronary artery bypass grafting (13%), mitral valve repair (7%), and partial/complete arch replacement (12%/4%), with no significant differences between porcine and mechanical root replacement. Overall hospital mortality was 7.3%, with no difference between the 2 types of valve prostheses (7.7% for porcine and 7.1% for mechanical root replacement; P=1.0). Follow-up averaged 5.4 ± 3.7 years (1096 patient-years) and was 100% complete. Freedom from aorta-related reoperation at 12 years was not statistically different between the groups (porcine: 94.9% versus mechanical: 96.1%; P=0.73). Survival was equivalent between both groups, with a 5-year survival of 86 ± 3% (porcine: 88 ± 4%; mechanical: 85 ± 3%; P=0.96) and a 10-year survival of 76% (porcine: 80 ± 7%; mechanical: 75 ± 5%; P=0.84). The linearized mortality rate was 3.1%/patient-year (porcine: 2.9%/patient-year; mechanical: 3.2%/patient-year). In quinquagenerians, long-term survival after stentless porcine xenograft aortic root replacement is equivalent to that after a mechanical Bentall procedure. These results bring into question the predominance of mechanical composite conduits for root replacement in quinquagenerians, particularly in the current era of transcatheter valve-in-valve procedures for structural valve deterioration.
Langer, Nathaniel B; Hamid, Nadira B; Nazif, Tamim M; Khalique, Omar K; Vahl, Torsten P; White, Jonathon; Terre, Juan; Hastings, Ramin; Leung, Diana; Hahn, Rebecca T; Leon, Martin; Kodali, Susheel; George, Isaac
2017-01-01
The experience with transcatheter aortic valve replacement is increasing worldwide; however, the incidence of potentially catastrophic cardiac or aortic complications has not decreased. In most cases, significant injuries to the aorta, aortic valve annulus, and left ventricle require open surgical repair. However, the transcatheter aortic valve replacement patient presents a unique challenge as many patients are at high or prohibitive surgical risk and, therefore, an open surgical procedure may not be feasible or appropriate. Consequently, prevention of these potentially catastrophic injuries is vital, and practitioners need to understand when open surgical repair is required and when alternative management strategies can be used. The goal of this article is to provide an overview of current management and prevention strategies for major complications involving the aorta, aortic valve annulus, and left ventricle. © 2016 American Heart Association, Inc.
Barili, Fabio; Freemantle, Nick; Folliguet, Thierry; Muneretto, Claudio; De Bonis, Michele; Czerny, Martin; Obadia, Jean Francois; Al-Attar, Nawwar; Bonaros, Nikolaos; Kluin, Jolanda; Lorusso, Roberto; Punjabi, Prakash; Sadaba, Rafael; Suwalski, Piotr; Benedetto, Umberto; Böning, Andreas; Falk, Volkmar; Sousa-Uva, Miguel; Kappetein, Pieter A; Menicanti, Lorenzo
2017-06-01
The PARTNER group recently published a comparison between the latest generation SAPIEN 3 transcatheter aortic valve implantation (TAVI) system (Edwards Lifesciences, Irvine, CA, USA) and surgical aortic valve replacement (SAVR) in intermediate-risk patients, apparently demonstrating superiority of the TAVI and suggesting that TAVI might be the preferred treatment method in this risk class of patients. Nonetheless, assessment of the non-randomized methodology used in this comparison reveals challenges that should be addressed in order to elucidate the validity of the results. The study by Thourani and colleagues showed several major methodological concerns: suboptimal methods in propensity score analysis with evident misspecification of the propensity scores (PS; no adjustment for the most significantly different covariates: left ventricular ejection fraction, moderate-severe mitral regurgitation and associated procedures); use of PS quintiles rather than matching; inference on not-adjusted Kaplan-Meier curves, although the authors correctly claimed for the need of balancing score adjusting for confounding factors in order to have unbiased estimates of the treatment effect; evidence of poor fit; lack of data on valve-related death.These methodological flaws invalidate direct comparison between treatments and cannot support authors' conclusions that TAVI with SAPIEN 3 in intermediate-risk patients is superior to surgery and might be the preferred treatment alternative to surgery. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Mihos, Christos G; Santana, Orlando; Pineda, Andres M; La Pietra, Angelo; Lamelas, Joseph
2014-01-01
We present our experience of concomitant right coronary artery bypass grafting (CABG) and aortic valve replacement performed via a right minithoracotomy in patients with coronary lesions not amenable to percutaneous intervention. A total of 17 patients underwent concomitant aortic valve replacement and right CABG between April 2008 and July 2013. A 5- to 6-cm minithoracotomy incision was made over the right second or third intercostal space, and the costochondral cartilage was transected. A saphenous vein bypass to the right coronary artery was then performed, initiating the anastomosis from the toe of the graft. Subsequently, the aortic valve was replaced using standard techniques. There were 6 men and 11 women. The median European System for Cardiac Operative Risk Evaluation II score mortality risk was 5% [interquartile range (IQR), 2%-8%]. The mean (SD) age was 77 (10) years, the left ventricular ejection fraction was 59% (8%), and the New York Heart Association functional class was 2.4 (0.8). One patient had a history of CABG. The mean (SD) cardiopulmonary bypass time was 168 (57) minutes, and the aortic cross-clamp time was 133 (36) minutes. Three patients underwent concomitant mitral valve surgery (replacement, 2; repair, 1). The median intensive care unit and hospital lengths of stay were 47 hours (IQR, 24-90) and 9 days (IQR, 5-13), respectively. There was one reoperation for bleeding, and there was one postoperative stroke. All patients were alive at a mean (SD) follow-up of 2 (1.1) years. Aortic valve replacement with concomitant CABG performed via a right minithoracotomy approach is feasible.
Cost-effectiveness of aortic valve replacement in the elderly: an introductory study.
Wu, YingXing; Jin, Ruyun; Gao, Guangqiang; Grunkemeier, Gary L; Starr, Albert
2007-03-01
With increased life expectancy and improved technology, valve replacement is being offered to increasing numbers of elderly patients with satisfactory clinical results. By using standard econometric techniques, we estimated the relative cost-effectiveness of aortic valve replacement by drawing on a large prospective database at our institution. By using aortic valve replacement as an example, this introductory report paves the way to more definitive studies of these issues in the future. From 1961 to 2003, 4617 adult patients underwent aortic valve replacement at our service. These patients were provided with a prospective lifetime follow-up. As of 2005, these patients had accumulated 31,671 patient-years of follow-up (maximum 41 years) and had returned 22,396 yearly questionnaires. A statistical model was used to estimate the future life years of patients who are currently alive. In the absence of direct estimates of utility, quality-adjusted life years were estimated from New York Heart Association class. The cost-effectiveness ratio was calculated by the patient's age at surgery. The overall cost-effectiveness ratio was approximately 13,528 dollars per quality-adjusted life year gained. The cost-effectiveness ratio increased according to age at surgery, up to 19,826 dollars per quality-adjusted life year for octogenarians and 27,182 dollars per quality-adjusted life year for nonagenarians. Given the limited scope of this introductory study, aortic valve replacement is cost-effective for all age groups and is very cost-effective for all but the most elderly according to standard econometric rules of thumb.
Izzo, Richard L; O'Hara, Ryan P; Iyer, Vijay; Hansen, Rose; Meess, Karen M; Nagesh, S V Setlur; Rudin, Stephen; Siddiqui, Adnan H; Springer, Michael; Ionita, Ciprian N
2016-02-27
3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.
NASA Astrophysics Data System (ADS)
Izzo, Richard L.; O'Hara, Ryan P.; Iyer, Vijay; Hansen, Rose; Meess, Karen M.; Nagesh, S. V. Setlur; Rudin, Stephen; Siddiqui, Adnan H.; Springer, Michael; Ionita, Ciprian N.
2016-03-01
3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis Carm bi-Plane angiography system. Results: After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion: With advances in image processing and 3D printing technology, it is possible to create realistic patientspecific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.
Fluid mechanics of heart valves.
Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S
2004-01-01
Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
Costs of transcatheter versus surgical aortic valve replacement in intermediate-risk patients.
Osnabrugge, Ruben L J; Head, Stuart J; Genders, Tessa S S; Van Mieghem, Nicolas M; De Jaegere, Peter P T; van der Boon, Robert M A; Kerkvliet, J Marco; Kalesan, Bindu; Bogers, Ad J J C; Kappetein, A Pieter; Hunink, M G Myriam
2012-12-01
Transcatheter aortic valve replacement (TAVR) offers a new treatment option for patients with aortic stenosis, but costs may play a decisive role in decision making. Current studies are evaluating TAVR in an intermediate-risk population. We assessed the in-hospital and 1-year follow-up costs of patients undergoing TAVR and surgical aortic valve replacement (SAVR) at intermediate operative risk and identified important cost components. We prospectively collected clinical data on 141 patients undergoing TAVR and 405 undergoing SAVR. Propensity score matching yielded 42 matched pairs at intermediate risk. Costs were assessed using a detailed resource-use approach and compared using bootstrap methods. In-hospital costs were higher in TAVR patients than in SAVR patients (€40802 vs €33354, respectively; p=0.010). The total costs at 1 year were €46217 vs €35511, respectively (p=0.009). The TAVR was less costly with regard to blood products, operating room use, and length-of-stay. For intermediate-risk patients with severe aortic stenosis the costs at 1 year are higher for TAVR than for SAVR. The difference was mainly caused by the higher costs of the transcatheter valve and was not compensated by the lower costs for blood products and hospital stay in TAVR patients. Therefore, SAVR remains a clinically and economically attractive treatment option. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Aortic valve replacement for Libman-Sacks endocarditis.
Keenan, Jack B; Janardhanan, Rajesh; Larsen, Brandon T; Khalpey, Zain
2016-10-04
A 24-year-old man with systemic lupus erythematosus and antiphospholipid syndrome complicated by lupus nephritis presented with acute limb ischaemia secondary to an embolus. Following embolectomy, the patient underwent a transthoracic echocardiogram which revealed a large vegetation on all three cusps of the aortic valve. The patient was taken for an urgent aortic valve replacement with a mechanical valve. Cultures of one cusp remained sterile. Histopathological examination of the remaining two cusps revealed sterile fibrin-rich thrombotic vegetations characteristic of non-bacterial thrombotic endocarditis. 2016 BMJ Publishing Group Ltd.
2011-01-01
Objectives To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. Methods Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. Results Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). Conclusions The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade. PMID:21699696
Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A
2014-05-01
The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.
Panholzer, Bernd; Cremer, Jochen; Haneya, Assad
2018-01-01
Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed. PMID:29552039
Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad
2018-01-01
Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.
Cardiac Surgery in Patients Infected with Human Immunodeficiency Virus
Abad, Cipriano; Cárdenes, Miguel Angel; Jiménez, Pedro Conrado; Armas, Mario-Vicente; Betancor, Pedro
2000-01-01
From January 1991 through December 1999, 5 consecutive patients who were infected with human immunodeficiency virus presented in need of cardiac surgery. All were men; the median age was 44 years. Two of them presented with mitral and aortic infectious valve endocarditis, 1 with tricuspid endocarditis, 1 with prosthetic valve endocarditis, and 1 with pericarditis and pericardial tamponade. Under cardiopulmonary bypass, the 4 patients with endocarditis underwent these procedures: mitral and aortic valve replacement (2), tricuspid valve replacement (1), and aortic valve replacement (reoperation) and concomitant repair of a mycotic ascending aortic aneurysm (1). In the patient who had pericardial effusion, subxifoid pericardiostomy and drainage were performed, and a pericardial window was created. There was no intraoperative mortality. The patient with pericardial effusion died 8 days after surgery; he was in septic shock and had multiple organ failure. Two deaths occurred at 2 and 63 months, due to hemoptysis and sudden death, respectively. The 2 patients who underwent double valve replacement are alive and in good condition after a median follow-up of 71 months. Cardiac surgery is indicated in selected patients infected by the human immunodeficiency virus. These patients are frequently drug abusers or homosexual. Valvular endocarditis is the most common finding. Hospital morbidity and mortality rates are higher than usual in this group of patients. PMID:11198308
Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P
2011-01-01
Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).
Morbidity following the Ross operation.
Gonzalez-Lavin, L; Robles, A; Graf, D
1988-09-01
Aortic valve replacement (AVR) with a pulmonary valve autograft (PVA) was first reported by Donald N. Ross in 1967. The expectation of this procedure was to avoid degenerative changes seen in other biological tissue valves such as calcification, attenuation, and rupture of the leaflets. Recent reports by the original investigator's group have confirmed the lack of degenerative changes in PVA. To corroborate their conclusions, the fate of 12 patients undergoing AVR with PVA by Dr. Gonzalez-Lavin has been ascertained. From March 1969 to June 1971, 12 patients underwent AVR with PVA. The right ventricular outflow tract (RVOT) was reconstructed with an aortic homograft valved conduit. The mean age was 42.7 years (range 21 to 52 years). The mean follow-up for 11 hospital survivors is 12.4 years. Three PVAs have been replaced; one following infective endocarditis at 13 years, and two at 15 and 73 months due to technical malalignment. There was no evidence of PVA degeneration during histologic examination of these explanted PVA. Six patients are alive and retain the original PVA at 12 years (55%). This analysis corroborates the conclusions of Dr. Ross and strongly suggests an immunological mechanism in the process of calcification of other biological tissue valves. The Ross operation is believed to be the preferred method of AVR in young patients.
MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.
Kistan, D; Booysen, M; Alexander, G; Madiba, T E
2017-06-01
Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients were younger than world literature suggests. Rheumatic heart disease was the common underlying pathology. Prosthetic valve thrombosis was common. More than half had emergency surgery. Mortality rate was negligible.
Valve leakage inspection, testing, and maintenance process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aikin, J.A.; Reinwald, J.W.
1989-01-01
Atomic Energy of Canada Limited-Research Company (AECL-RC), Chalk River, has more than 50 person-years dedicated toward the leak-free valve. In the early 1970s, the Chalk River Nuclear Laboratories (CRNL) developed valve stem live-loading and recently completed the packing tests for the Electric Power Research Institute (EPRI)-funded Valve Packing Improvement Study. Current safety concerns with asbestos-based valve packings and the difficulty in removing newer graphite packings prompted CRNL to investigate methods to improve valve repacking procedures. The present practice of valve packing replacement is very labor-intensive, requiring use of hand tools such as corkscrew devices and special packing picks. Use ofmore » water jets to cut or fragment the packing for withdrawal from the stuffing box does improve the process, but removal of the lantern or junk rings is still difficult. To address these problems, AECL-RC has developed a unique valve maintenance process designed to reduce person-rem exposures, the risk of scoring the stem or stuffing box, and maintenance costs and to improve the engineering quality of valve repair.« less
Aortic valve repair using a differentiated surgical strategy.
Langer, Frank; Aicher, Diana; Kissinger, Anke; Wendler, Olaf; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim
2004-09-14
Reconstruction of the aortic valve for aortic regurgitation (AR) remains challenging, in part because of not only cusp or root pathology but also a combination of both can be responsible for this valve dysfunction. We have systematically tailored the repair to the individual pathology of cusps and root. Between October 1995 and August 2003, aortic valve repair was performed in 282 of 493 patients undergoing surgery for AR and concomitant disease. Root dilatation was corrected by subcommissural plication (n=59), supracommissural aortic replacement (n=27), root remodeling (n=175), or valve reimplantation within a graft (n=24). Cusp prolapse was corrected by plication of the free margin (n=157) or triangular resection (n =36), cusp defects were closed with a pericardial patch (n=16). Additional procedures were arch replacement (n=114), coronary artery bypass graft (n=60) or mitral repair (n=24). All patients were followed-up (follow-up 99.6% complete), and cumulative follow-up was 8425 patient-months (mean, 33+/-27 months).Results- Eleven patients died in hospital (3.9%). Nine patients underwent reoperation for recurrent AR (3.3%). Actuarial freedom from AR grade > or =II at 5 years was 81% for isolated valve repair, 84% for isolated root replacement, and 94% for combination of both; actuarial freedom from reoperation at 5 years was 93%, 95%, and 98%, respectively. No thromboembolic events occurred, and there was 1 episode of endocarditis 4.5 years postoperatively. Aortic valve repair is feasible even for complex mechanisms of AR with a systematic and individually tailored approach. Operative mortality is low and mid-term durability is encouraging. The incidence of valve-related morbidity is low compared with valve replacement.
One-year outcomes after rapid-deployment aortic valve replacement.
Young, Christopher; Laufer, Günther; Kocher, Alfred; Solinas, Marco; Alamanni, Francesco; Polvani, Gianluca; Podesser, Bruno K; Aramendi, Jose Ignacio; Arribas, Jose; Bouchot, Olivier; Livi, Ugolino; Massetti, Massimo; Terp, Kim; Giot, Christophe; Glauber, Mattia
2018-02-01
The goals of rapid-deployment aortic valve replacement include facilitation of minimally invasive surgery and reduced aortic crossclamp time. We report the short-term outcomes of a series of 493 patients undergoing rapid-deployment aortic valve replacement with the EDWARDS INTUITY valve system (Edwards Lifesciences, LLC, Irvine, Calif). Assessing Standard oF Care and Clinical Outcomes UsiNg the EDWARDS INTUITY VAlve SysTem in a European multI-center, Active, pOst-market surveillaNce Study was a prospective, multicenter (n = 26) European registry designed to evaluate the safety and performance of the valve system. During rapid-deployment aortic valve replacement, device technical success and crossclamp time were assessed. Procedural outcomes, hemodynamic performance, and various adverse events and clinical outcomes were evaluated up to 2 years. Between 2012 and 2014, 493 of 517 enrolled patients successfully received implants with the study valve (95.4% technical success). Mean crossclamp times for 163 full sternotomies, 128 mini-upper sternotomies, and 36 right anterior thoracotomies isolated aortic valve replacements were 47.3, 52.0, and 73.3 minutes, respectively. Mean follow-up was 1.8 years, with 870 total patient-years of follow-up. Mean effective orifice area increased from 0.72 (baseline) to 1.88 cm 2 , and mean pressure gradient decreased from 47.6 to 9.6 mm Hg (1 year). Mean effective orifice area index increased (0.39-1.01 cm 2 /m 2 ), and 28 of 287 patients (9.8%) exhibited severe prosthesis-patient mismatch at 1 year. After 1 year, 68.1% and 21.7% of patients were in New York Heart Association class I and II, respectively. Freedom from death, major bleeding, major perivalvular leak, reoperation, and device explant at 1 year were 0.935, 0.939, 0.976, 0.975, and 0.983, respectively. These results demonstrate commendable safety and performance of the test valve system over the short term in a broad European setting. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.
Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban
2018-01-01
Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.
Basel, Halil; Aydin, Unal; Kutlu, Hakan; Dostbil, Aysenur; Karadag, Melike; Odabasi, Dolunay; Aydin, Cemalettin
2010-08-01
The aim of this study was to compare De Vega semicircular annuloplasty and a new biodegradable ring annuloplasty technique in patients requiring surgical intervention for tricuspid valve disease with concomitant disease of the mitral valve. Between January 2004 and May 2008, 129 consecutive patients underwent annuloplasty procedures to correct tricuspid valve regurgitation during a concomitant mitral valve operation requiring replacement. Additionally, 24 patients underwent aortic valve replacement (AVR), 11 underwent coronary artery bypass grafting (CABG), 5 underwent AVR plus CABG, 3 underwent mitral valve replacement plus atrial septal defect (ASD) closure, and 2 underwent ASD closure. The patients in this study were assigned to 2 groups: Kalangos ring annuloplasty was performed in 67 patients (group 1), and De Vega semicircular annuloplasty was performed in the remaining 62 patients (group 2). Both tricuspid valve repair techniques produced a low rate of complications; however, the number of patients who developed residual tricuspid regurgitation was significantly lower in group 1. The biodegradable ring annuloplasty technique may be used easily and safely in moderate and severe cases of tricuspid regurgitation; however, larger clinical series are necessary to confirm our promising results.
Sutton, Steve W.; Marcel, Randy
2007-01-01
We present the first reported case of an aortic valve replacement operation without blood transfusion in a 62-year-old Jehovah's Witness with dialysis-dependent chronic renal failure, severe anemia, severe aortic stenosis, and symptomatic angina with minimal exertion after an accident in which she suffered fractures of both her right arm and leg. She underwent successful valve replacement surgery after preoperative stabilization of her fractures and high-dose erythropoietin and iron supplement therapy preoperatively and postoperatively. The intraoperative blood conservation technique included a novel approach with a miniature cardiopulmonary bypass circuit and microplegia with limited hemodilution. High-risk valve surgery in patients who are Jehovah's Witnesses can be successful with a carefully planned multimodality blood conservation strategy. PMID:17256040
Transapical JenaValve in a patient with mechanical mitral valve prosthesis.
O' Sullivan, Katie E; Casserly, Ivan; Hurley, John
2015-04-01
We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.
Dohmen, Pascal M; Binner, Christian; Mende, Meinhart; Bakhtiary, Farhad; Etz, Christian; Pfannmüller, Bettina; Davierwala, Piroze; Borger, Michael A; Misfeld, Martin; Mohr, Friedrich W
2015-02-01
The high risk of morbidity and mortality for patients on hemodialysis who are undergoing cardiac surgery is increased for those with active infective endocarditis (AIE). This retrospective observational single-center study evaluated the impact of chronic hemodialysis on the outcome of aortic valve replacement in patients with aortic AIE. Data were retrospectively collected for consecutive patients undergoing aortic valve surgery for AIE diagnosed according to modified Duke criteria between October 1994 and January 2011. Characteristics and outcomes of patients receiving preoperative chronic hemodialysis were analyzed. Aortic valve AIE was present in 992 patients. Forty-five (4.5%) of the aortic valve AIE patients were receiving long-term hemodialysis preoperatively, 19 of whom (42.2%) had diabetes mellitus. Mean logistic EuroSCORE was 64.2% ± 32.2%. Twenty-four preoperative septic emboli were found in 15 patients. Results of microbiologic cultures were positive in 36 patients, with the major causative organisms identified as Staphylococcus aureus (n = 17) and Enterococcus faecalis (n = 10). Isolated aortic valve replacement was performed in 19 patients (42.2%), and 26 patients (57.8%) underwent concomitant procedures. The mean follow-up was 5.3 ± 5.2 years (range, 0.1 to 17.1 years). Postoperative complications occurred in 30 patients (66.7%). Nineteen patients (42.2%) died within 30 days of surgery, which in 8 patients was attributable to a cardiac cause. In patients receiving chronic hemodialysis who undergo aortic valve replacement for acute AIE, postoperative mortality is high, especially in patients undergoing aortic root replacement or culture-negative AIE. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?
Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim
2004-11-01
Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.
Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad
2018-05-20
Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.
Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.
Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki
2013-01-01
The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves
Roberts, William Clifford; Vowels, Travis James; Ko, Jong Mi; Filardo, Giovanni; Hebeler, Robert Frederick; Henry, Albert Carl; Matter, Gregory John; Hamman, Baron Lloyd
2011-03-01
There is debate concerning whether an aneurysmal ascending aorta should be replaced when associated with a dysfunctioning aortic valve that is to be replaced. To examine this issue, we divided the patients by type of aortic valve dysfunction-either aortic stenosis (AS) or pure aortic regurgitation (AR)-something not previously undertaken. Of 122 patients with ascending aortic aneurysm (unassociated with aortitis or acute dissection), the aortic valve was congenitally malformed (unicuspid or bicuspid) in 58 (98%) of the 59 AS patients, and in 38 (60%) of the 63 pure AR patients. Ascending aortic medial elastic fiber loss (EFL) (graded 0 to 4+) was zero or 1+ in 53 (90%) of the AS patients, in 20 (53%) of the 38 AR patients with bicuspid valves, and in all 12 AR patients with tricuspid valves unassociated with the Marfan syndrome. An unadjusted analysis showed that, among the 96 patients with congenitally malformed valves, the 38 AR patients had a significantly higher likelihood of 2+ to 4+ EFL than the 58 AS patients (crude odds ratio: 8.78; 95% confidence interval: 2.95, 28.13). These data strongly suggest that the type of aortic valve dysfunction-AS versus pure AR-is very helpful in predicting loss of aortic medial elastic fibers in patients with ascending aortic aneurysms and aortic valve disease.
Echocardiographic versus histologic findings in Marfan syndrome.
Gu, Xiaoyan; He, Yihua; Li, Zhian; Han, Jiancheng; Chen, Jian; Nixon, J V Ian
2015-02-01
This retrospective study attempted to establish the prevalence of multiple-valve involvement in Marfan syndrome and to compare echocardiographic with histopathologic findings in Marfan patients undergoing valvular or aortic surgery. We reviewed echocardiograms of 73 Marfan patients who underwent cardiovascular surgery from January 2004 through October 2009. Tissue histology was available for comparison in 29 patients. Among the 73 patients, 66 underwent aortic valve replacement or the Bentall procedure. Histologic findings were available in 29 patients, all of whom had myxomatous degeneration. Of 63 patients with moderate or severe aortic regurgitation as determined by echocardiography, 4 had thickened aortic valves. The echocardiographic findings in 18 patients with mitral involvement included mitral prolapse in 15. Of 11 patients with moderate or severe mitral regurgitation as determined by echocardiography, 4 underwent mitral valve repair and 7 mitral valve replacement. Histologic findings among mitral valve replacement patients showed thickened valve tissue and myxomatous degeneration. Tricuspid involvement was seen echocardiographically in 8 patients, all of whom had tricuspid prolapse. Two patients had severe tricuspid regurgitation, and both underwent repair. Both mitral and tricuspid involvement were seen echocardiographically in 7 patients. Among the 73 patients undergoing cardiac surgery for Marfan syndrome, 66 had moderate or severe aortic regurgitation, although their valves manifested few histologic changes. Eighteen patients had mitral involvement (moderate or severe mitral regurgitation, prolapse, or both), and 8 had tricuspid involvement. Mitral valves were most frequently found to have histologic changes, but the tricuspid valve was invariably involved.
[Short and long term results of aortic valve replacement in patients 80 years of age and older].
Mortasawi, A; Gehle, S; Yaghmaie, M; Schröder, T; Ennker, I C; Rosendahl, U; Albert, A; Ennker, J
2001-03-01
Due to demographic changes in average life expectancy the age of patients undergoing cardiac surgery is increasing as well. We have reviewed the short- and long-term outcome in patients over 80 years of age after aortic valve replacement with or without concomitant coronary grafting. From 1.1.1995 until 31.12.1999, 126 patients (93 women, 33 men between 80 and 89 years, 82.8 +/- 2.4) underwent aortic valve replacement. 64 patients (group A) received isolated valve replacement, 62 (group B) underwent myocardial revascularization as well. The 30-day hospital mortality rate was 6.3% for group A and 14.5% for group B. The follow-up time ranged between 3 and 63 months (32 +/- 16). None of the patients had to be reoperated for prosthetic valve dysfunction or endocarditis. Bleeding complications due to anticoagulation therapy were observed by one patient from group A 3 years after the operation. Of the 15 deaths during the follow-up period seven (47%) were cardiac in nature and two (13%) related to stroke. Acturial survival rates for group A were 89%, 85% and 77% at 1, 2 and 3 years, and for group B 76%, 72% and 70%. Permanent nursing care was not required 1 year after the operation by 100% of patients in group A (2 years: 98%, 3 years 95%) and by 100% of patients in group B (2 years: 93%, 3 years: 90%). At an interval of 1 year after the operation 96% of patients in group A had not been hospitalized as a result of cardiac disorders (2 years: 96%, 3 years: 94%). The rates for group B were 88%, 81% and 75%. Compared with younger age groups, aortic valve replacement in patients 80 years of age and older is associated with a distinctly increased mortality and morbidity. However, our data suggest that considering the poor prognosis of conservative therapy of symptomatic aortic valve disease, functional status as well as life expectancy in this age group seem to be positively influenced by aortic valve replacement.
Tapia, M; Latrémouille, C; Chabert, J P; Fabiani, J N
1995-12-01
The authors report the case of major tricuspid regurgitation occurring early after mitral valve replacement. The mechanism was demonstrated at reoperation: the heart was deformed by a posterior pericardial effusion and cardiodiaphragmatic pericardial adhesions.
Reynolds, Matthew R.; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A.; Magnuson, Elizabeth A.; Galper, Benjamin Z.; Meduri, Christopher U.; Arnold, Suzanne V.; Baron, Suzanne J.; Reardon, Michael J.; Adams, David H.; Popma, Jeffrey J.; Cohen, David J.
2016-01-01
Background Prior studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. Objectives The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. Methods We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk pivotal trial. Empirical data regarding survival and quality of life (QOL) over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. perspective. Results Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month QOL. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years (QALYs; 0.41 life-years [LYs]) with 3% discounting. Lifetime incremental cost-effectiveness ratios (ICERs) were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ~$1,650 would lead to an ICER <$50,000/QALY gained. Conclusions In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. standards. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. PMID:26764063
MANPRINT Methods Monograph: Aiding the Development of Manpower-Based System Evaluation
1989-06-01
zone below tree level where threats are known to be (the actual number of threats may vary). Weather conditions are VFR. The helicopter pops up to...12.0 Replace 13.3 Bearing, connecting Inspect 6.2 Replace 6.2 0105 Camshaft Inspect 7.2 Replace 7.2 Cover, cylinder head Inspect .2 (valve cover...matrix to analyze the data and identify task clusters. . Outputs and Use of Cluster Analysis 1. Hierarchical cluster tree (taxonomy) of system tasks will
Lee, Chung-Hao; Amini, Rouzbeh; Gorman, Robert C.; Gorman, Joseph H.; Sacks, Michael S.
2013-01-01
Estimation of regional tissue stresses in the functioning heart valve remains an important goal in our understanding of normal valve function and in developing novel engineered tissue strategies for valvular repair and replacement. Methods to accurately estimate regional tissue stresses are thus needed for this purpose, and in particular to develop accurate, statistically informed means to validate computational models of valve function. Moreover, there exists no currently accepted method to evaluate engineered heart valve tissues and replacement heart valve biomaterials undergoing valvular stresses in blood contact. While we have utilized mitral valve anterior leaflet valvuloplasty as an experimental approach to address this limitation, robust computational techniques to estimate implant stresses are required. In the present study, we developed a novel numerical analysis approach for estimation of the in-vivo stresses of the central region of the mitral valve anterior leaflet (MVAL) delimited by a sonocrystal transducer array. The in-vivo material properties of the MVAL were simulated using an inverse FE modeling approach based on three pseudo-hyperelastic constitutive models: the neo-Hookean, exponential-type isotropic, and full collagen-fiber mapped transversely isotropic models. A series of numerical replications with varying structural configurations were developed by incorporating measured statistical variations in MVAL local preferred fiber directions and fiber splay. These model replications were then used to investigate how known variations in the valve tissue microstructure influence the estimated ROI stresses and its variation at each time point during a cardiac cycle. Simulations were also able to include estimates of the variation in tissue stresses for an individual specimen dataset over the cardiac cycle. Of the three material models, the transversely anisotropic model produced the most accurate results, with ROI averaged stresses at the fully-loaded state of 432.6±46.5 kPa and 241.4±40.5 kPa in the radial and circumferential directions, respectively. We conclude that the present approach can provide robust instantaneous mean and variation estimates of tissue stresses of the central regions of the MVAL. PMID:24275434
The mechanobiology of mitral valve function, degeneration, and repair
Richards, Jennifer M.; Farrar, Emily J.; Kornreich, Bruce G.; Moïse, N. Sydney; Butcher, Jonathan T.
2013-01-01
In degenerative valve disease, the highly organized mitral valve leaflet matrix stratification is progressively destroyed and replaced with proteoglycan rich, mechanically inadequate tissue. This is driven by the actions of originally quiescent valve interstitial cells that become active contractile and migratory myofibroblasts. While treatment for myxomatous mitral valve disease in humans ranges from repair to total replacement, therapies in dogs focus on treating the consequences of the resulting mitral regurgitation. The fundamental gap in our understanding is how the resident valve cells respond to altered mechanical signals to drive tissue remodeling. Despite the pathological similarities and high clinical occurrence, surprisingly little mechanistic insight has been gleaned from the dog. This review presents what is known about mitral valve mechanobiology from clinical, in vivo, and in vitro data. There are a number of experimental strategies already available to pursue this significant opportunity, but success requires the collaboration between veterinary clinicians, scientists, and engineers. PMID:22366572
Mitral valve replacement for mitral stenosis: A 15-year single center experience.
Al Mosa, Alqasem F; Omair, Aamir; Arifi, Ahmed A; Najm, Hani K
2016-10-01
Mitral valve replacement with either a bioprosthetic or a mechanical valve is the treatment of choice for severe mitral stenosis. However, choosing a valve implant type is still a subject of debate. This study aimed to evaluate and compare the early and late outcomes of mitral valve replacement [mechanical (MMV) vs. bioprosthetic (BMV)] for severe mitral stenosis. A retrospective cohort study was performed on data involving mitral stenosis patients who have undergone mitral valve replacement with either BMV (n = 50) or MMV (n = 145) valves from 1999 to 2012. Data were collected from the patients' records and follow-up through telephone calls. Data were analyzed for early and late mortality, New York Heart Association (NYHA) functional classes, stroke, pre- and postoperative echocardiographic findings, early and late valve-related complications, and survival. Chi-square test, logistic regression, Kaplan-Meier curve, and dependent proportions tests were some of the tests employed in the analysis. A total of 195 patients were included in the study with a 30-day follow-up echocardiogram available for 190 patients (97.5%), while 103 (53%) were available for follow-up over the telephone. One patient died early postoperatively; twelve patients died late in the postoperative period, six in the bioprosthesis group and six in the mechanical group. The late mortality had a significant association with postoperative stroke (p < 0.001) and postoperative NYHA Classes III and IV (p = 0.002). Postoperative NYHA class was significantly associated with age (p = 0.003), pulmonary disease (p = 0.02), mitral valve implant type (p = 0.01), and postoperative stroke (p = 0.02); 14 patients had strokes in the mechanical (9) and in the bioprosthetic (5) groups. NYHA classes were significantly better after the replacement surgeries (p < 0.001). BMV were significantly associated with worse survival (p = 0.03), worse NYHA postoperatively (p = 0.01), and more reoperations (p = 0.006). Survival was significantly better with MMV (p = 0.03). When the two groups were matched for age and mitral regurgitation, the analysis revealed that BMV were significantly associated with reoperations (p = 0.02) but not significantly associated with worse survival (p = 0.4) or worse NYHA (p = 0.4). MMV replacement in mitral stenosis patients is associated with a lower reoperation rate, but there was no difference in survival compared with BMV replacement.
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
21 CFR 870.3935 - Prosthetic heart valve holder.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...
De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura
2016-01-01
Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146
Vascular complications of transcatheter aortic valve replacement: A concise literature review
Chaudhry, Muhammad Ali; Sardar, Muhammad Rizwan
2017-01-01
Transcatheter aortic valve replacement (TAVR) is a relatively newer therapeutic modality which offers a promising alternative to surgical aortic valve replacement for patients with prohibitive, high and intermediate surgical risk. The increasing trend to pursue TAVR in these patients has also led to growing awareness of the associated potential vascular complications. The significant impact of these complications on eventual clinical outcome and mortality makes prompt recognition and timely management a critical factor in TAVR patients. We hereby present a concise review with emphasis on diverse vascular complications associated with TAVR and their effective management to improve overall clinical outcomes. PMID:28824787
De Palma, G D; Salvatori, F; Masone, S; Simeoli, I; Rega, M; Celiento, M; Persico, G
2007-09-01
A 58-year old man was admitted to the hospital because of melena. He had a 1-year history of mechanical aortic valve replacement and coronary stent placement because of myocardial infarction and he was taking warfarin and clopidogrel. Esophagogastroduodenoscopy and colonoscopy were negative for bleeding. Capsule endoscopy showed bleeding diffuse angiodysplasia of the small bowel. The patient was treated with octreotide 20 mg, at monthly interval. After 25 months there had been no recurrence of gastrointestinal bleeding. The case suggests that mechanical valve replacement may not prevent gastrointestinal bleeding in Heyde syndrome and that octreotide treatment should be considered in these cases.
Izzo, Richard L.; O’Hara, Ryan P.; Iyer, Vijay; Hansen, Rose; Meess, Karen M.; Nagesh, S.V. Setlur; Rudin, Stephen; Siddiqui, Adnan H.; Springer, Michael; Ionita, Ciprian N.
2017-01-01
3D printing an anatomically accurate, functional flow loop phantom of a patient’s cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient’s cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. Results After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone. PMID:28615797
Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.
Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René
2017-06-01
Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.
Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt
2014-07-01
Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral regurgitation, by virtue of their key features as well as effective crimping. These models will be fabricated and put to all the aforementioned tests before being taken for animal trials. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Robotic artificial chordal replacement for repair of mitral valve prolapse.
Brunsting, Louis A; Rankin, J Scott; Braly, Kimberly C; Binford, Robert S
2009-07-01
Artificial chordal replacement (ACR) has emerged as a superior method of mitral valve repair with excellent early and late efficacy. It is also ideal to combine with robotic techniques for correction of mitral prolapse, and this article presents a current method of robotic Gore-Tex ACR. Patients with isolated posterior leaflet prolapse are approached with the fourth-generation DaVinci robotic system and endoaortic balloon occlusion. A pledgetted anchor stitch is placed in a papillary muscle, and a 2-o Gore-Tex suture is passed through the anchor pledget. After full annuloplasty ring placement, the Gore-Tex suture is woven into the prolapsing segment and positioned temporarily with robotic forceps. Chordal length is then "adjusted" by lengthening or shortening the temporary knot over 1-cm increments as the valve is tested by injection of cold saline into the ventricle. After achieving good leaflet position and valve competence, the chord is tied permanently. The "adjustable" ACR procedure preserves leaflet surface area and produces a competent valve in the majority of patients. Postoperative transesophageal echo shows a large surface area of coaptation. Patient recovery is facilitated by the minimally invasive approach, while long-term stability of similar open ACR techniques have been excellent with a 2% to 3% failure rate over 10 years of follow-up. Robotic Gore-Tex ACR without leaflet resection is a reproducible procedure that simplifies mitral repair for prolapse. The outcomes observed in early robotic applications have been excellent. It is suggested that most patients with simple prolapse might validly be approached in this manner.
Nakamura, Kenta; Passeri, Jonathan J; Inglessis-Azuaje, Ignacio
2017-07-01
We report a case of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement and subsequent percutaneous closure. The diagnosis and treatment of this rare complication is illustrated through multi-modality imaging. We hypothesize that the patient's heavily calcified bicuspid aortic valve anatomy led to asymmetric deployment of the transcatheter aortic valve replacement (TAVR) prosthesis, traumatizing the right sinus of Valsalva at the distal edge of the TAVR stent and ultimately fistulized to the right ventricle. The patient acutely decompensated with heart failure five days after TAVR and underwent emergent intervention. The aorto-right ventricular fistula was closed using an 18-mm septal occluder device with marked clinical recovery. Transcatheter closure is a viable treatment option for acute aorto-right ventricular fistula. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
The German Aortic Valve Registry (GARY): in-hospital outcome
Hamm, Christian W.; Möllmann, Helge; Holzhey, David; Beckmann, Andreas; Veit, Christof; Figulla, Hans-Reiner; Cremer, J.; Kuck, Karl-Heinz; Lange, Rüdiger; Zahn, Ralf; Sack, Stefan; Schuler, Gerhard; Walther, Thomas; Beyersdorf, Friedhelm; Böhm, Michael; Heusch, Gerd; Funkat, Anne-Kathrin; Meinertz, Thomas; Neumann, Till; Papoutsis, Konstantinos; Schneider, Steffen; Welz, Armin; Mohr, Friedrich W.
2014-01-01
Background Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. Methods and results A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). Conclusion The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients. PMID:24022003
Prosthetic valve endocarditis due to Propionibacterium acnes.
van Valen, Richard; de Lind van Wijngaarden, Robert A F; Verkaik, Nelianne J; Mokhles, Mostafa M; Bogers, Ad J J C
2016-07-01
To study the characteristics of patients with Propionibacterium acnes prosthetic valve endocarditis (PVE) who required surgery. A single-centre retrospective cohort study was conducted during a 7-year period. Patients with definite infective P. acnes endocarditis, according to the modified Duke criteria, were included. An extended culture protocol was applied. Information on medical health status, surgery, antibiotic treatment and mortality was obtained. Thirteen patients fulfilled the criteria for P. acnes endocarditis (0.53% of 2466 patients with valve replacement in a 7-year period). All patients were male and had a previous valve replacement. The health status of patients was poor at diagnosis of P. acnes PVE. Most patients (11 of 13, 85%) were admitted with signs of heart failure due to a significant paravalvular leak; 2 of 13 (15%) patients presented with septic emboli. Twelve patients needed redo surgery, whereas one could be treated with antibiotic therapy only. The time between the index surgery and presentation with P. acnes PVE varied between 5 and 135 months (median 26.5 months). Replacement and reconstruction of the dysfunctional valve and affected anatomical structures was mainly performed with a mechanical valve (n = 5, 42%) or a (bio-) Bentall prosthesis (n = 6, 50%). Antibiotic therapy consisted of penicillin with or without rifampicin for 6 weeks after surgery. The mortality in this series was low (n = 1, 8%) and no recurrent endocarditis was found during a median follow-up of 38 months. Propionibacterium acnes PVE is a rare complication after valve surgery. Redo surgery is often required. Treatment of the dysfunctional prosthetic aortic valve most often consists of root replacement, in combination with antibiotic therapy. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Nakajima, Masato; Tsuchiya, Koji; Fukuda, Shoji; Morimoto, Hironobu; Mitsumori, Yoshitaka; Kato, Kaori
2006-04-01
Aortic surgery for progressive aortic valve disease or aortic aneurysm after previous coronary artery bypass grafting (CABG) is a challenging procedure. We report the outcome of aortic reoperation after previous CABG and evaluate our management of patent grafts and our methods for obtaining myocardial protection. From February 2001 to July 2003, 6 patients with progressive aortic valve disease and aneurysm of the thoracic aorta were operated on. The group comprised 3 men and 3 women with a mean age of 67.6 years. There were 4 patients with an aneurysm of the aortic arch, 1 with chronic ascending aortic dissection, and 1 with progressive aortic valve stenosis. The interval between previous CABG and aortic surgery was 74.0 +/- 44.2 months. All reoperations were performed via median resternotomy. Myocardial protection was obtained by hypothermic perfusion of patent in-situ arterial grafts following cold-blood cardioplegia administration via the aortic root under aortic cross clamping. The operative procedure was aortic arch replacement in 4 patients, ascending aortic replacement with double CABG in 1, and aortic valve replacement in 1. All patients survived the reoperation. Postoperative maximum creatine kinase-MB was 49.2 +/- 29.8 and no new Q-waves occurred in the electrocardiogram nor were any new wall motion abnormalities recognized on echocardiography. There were no late deaths during a follow-up of 30.7 months. Reoperative aortic procedures after CABG can be performed safely with myocardial protection via hypothermic perfusion of a patent in-situ arterial graft.
Thompson, Jess L; Sundt, Thoralf M; Sarano, Maurice E; Santrach, Paula J; Schaff, Hartzell V
2008-06-01
Patient self-testing of the international normalized ratio (INR) has been shown to improve management of anticoagulation with warfarin and reduce risks of thromboembolism and bleeding. Self-testing instruction usually begins several weeks after hospital discharge. We evaluated the feasibility of in-hospital INR self-testing instruction in patients recovering from valve replacement. We instituted an education program on a self-testing device before hospital discharge in 50 adult patients (median age, 54 years; 66% men) undergoing cardiac valve replacement with mechanical prostheses. Patients were monitored for 1 month to assess their ability to self-test and the accuracy of the INR measurements. Self-testing instruction began on postoperative day 4 (range, 1 to 8 days). Each patient had an average of 3.5 teaching sessions; each session lasted approximately 20 minutes. One month after discharge, all patients (98%) but 1 were able to self-test. No patient required interval instruction. One bleeding episode occurred in a patient whose INR exceeded the therapeutic range. Once warfarin doses were stabilized, 5 patients had subtherapeutic INR values on self-testing. The mean INR test result obtained from the coagulometer correlated well with values obtained by laboratory determination (r = 0.79). This evaluation of an in-hospital education program demonstrates that patients are able to learn INR self-testing and that most will continue to use the method without the need for interval instruction. Improved anticoagulation management by early introduction of INR self-testing should reduce thromboembolic and hemorrhagic complications after valve replacement.
Valve exploiting the principle of a side channel turbine
NASA Astrophysics Data System (ADS)
Jandourek, Pavel; Pochylý, František; Haban, Vladimír
2017-04-01
The presented article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Pressure reducing valves are a source of high hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the reducing valve and the side channel turbine. The basis for the design is the loss characteristics of the pressure reducing valve. Thereby create a new kind of turbine valve with speed-controlled flow in dependence of the runner revolution. It is technical innovation and new renewable source of energy, which can be in future used in rehabilitation or projecting of pumped-storage power plants. It also increases the power of the power plant.
Repair for mitral stenosis due to pannus formation after Duran ring annuloplasty.
Song, Seunghwan; Cho, Seong Ho; Yang, Ji-Hyuk; Park, Pyo Won
2010-12-01
Mitral stenosis after mitral repair with using an annuloplasty ring is not common and it is almost always due to pannus formation. Mitral valve replacement was required in most of the previous cases of pannus covering the mitral valve leaflet, which could not be stripped off without damaging the valve leaflets. In two cases, we removed the previous annuloplasty ring and pannus without leaflet injury, and we successfully repaired the mitral valve. During the follow-up of 4 months and 39 months respectively, we observed improvement of the patients' symptoms and good valvular function. Redo mitral repair may be a possible method for treating mitral stenosis due to pannus formation after ring annuloplasty. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo
2017-12-01
Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.
Medium-term outcome of Toronto aortic valve replacement: single center experience.
Li, Wei; Price, Susanna; O'Sullivan, Christine A; Kumar, Pankaj; Jin, Xu Y; Henein, Michael Y; Pepper, John R
2008-09-26
Long-term competence of any aortic prosthesis is critical to its clinical durability. Bioprosthetic valves, and in particular the stentless type have been proposed to offer superior haemodynamic profiles with consequent potential for superior left-ventricular mass regression. These benefits however are balanced by the potential longevity of the implanted valve. The aims of this study were to assess medium-term Toronto aortic valve function and its effect on left-ventricular function. Between 1992 and 1996 86 patients underwent Toronto aortic valve replacement for aortic valve disease and were followed up annually. Prospectively collected data was analyzed for all patients where detailed echocardiographic follow-up was available. Echocardiographic studies were analyzed at 2+/-0.6 and 6+/-1.4 years after valve replacement. Data collected included left-ventricular systolic and diastolic dimensions, fractional shortening and left-ventricular mass. In addition, data on aortic valve and root morphology, peak aortic velocities, time velocity integral, stroke volume and the mechanism of valve failure where relevant, were also collected. Complete echocardiographic data were available for eighty-four patients, age 69+/-9 years, 62 male. Additional coronary artery bypass grafting was performed in 38% of patients. Twelve (14%) valves had failed during follow-up, 7 (8%) requiring re-operation. Valve failure was associated with morphologically bicuspid native aortic valve (9/12), and progressive dilatation of the aortic sinuses, sino-tubular junction and ascending aorta (11/12). Left-ventricular mass index remained high (184+/-75 g/m(2)) and did not continue to regress between early and medium-term follow-up (175.8+/-77 g/m(2)). Although more than 90% of implanted Toronto aortic valves remained haemodynamically stable with low gradient at medium-term follow-up, young age and larger aortic dimensions in patients with valve failure suggest better outcome if used in the elderly with normal aortic root geometry.
Auriemma, Stefano; D'Onofrio, Augusto; Brunelli, Massimo; Magagna, Paolo; Paccanaro, Mariemma; Rulfo, Fanny; Fabbri, Alessandro
2006-09-01
The Edwards Lifesciences Prima Plus stentless valve (ELSV) is a bioprosthesis manufactured from a porcine aortic root. The study aim was to evaluate late clinical outcomes after aortic valve replacement (AVR) with ELSV implanted as a miniroot in patients with aortic valve disease. Between 1993 and 2004, 318 patients (232 males, 86 females; mean age 69 +/- 9 years; range: 37-83 years) underwent AVR with the ELSV. Preoperatively, 102 patients (32%), 162 (51%) and 54 (17%) were in NYHA classes I/II, III and IV, respectively. Aortic stenosis, aortic regurgitation and combined lesions were present in 124 patients (39%), 114 (36%) and 41 (13%), respectively. Twenty patients (6%) were referred for an acute aortic dissection, 20 (6%) for an aortic root aneurysm, and 139 (44%) had an associated aneurysmal dilatation of the ascending aorta. The ascending aorta was replaced in 159 patients (50%); aortic arch replacement was required in 10 (3%). Coronary artery bypass graft was performed in 86 patients (27%). The follow up was based on clinical data. Operative mortality was 5% (n = 17). There were 49 late deaths (5.2%/pt-yr). Valve-related mortality occurred in 10 patients (1%/pt-yr). Actuarial survival at five and 10 years was 78% and 33%, respectively. Actuarial freedom from valve reoperation and structural valve deterioration at 10 years were 100% and 64%. Actuarial freedom from embolic events and endocarditis at 10 years were 84% and 81%, respectively. The ELSV, when implanted as a miniroot, provided good early and long-term results in terms of survival and freedom from major complications.
Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William
2017-11-20
Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.
Gunning, Paul S.; Saikrishnan, Neelakantan; Yoganathan, Ajit P.; McNamara, Laoise M.
2015-01-01
Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a ‘peel-back’ leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve. PMID:26674192
Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan
2015-12-14
Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.
Automatic Mesh Generation of Hybrid Mesh on Valves in Multiple Positions in Feedline Systems
NASA Technical Reports Server (NTRS)
Ross, Douglass H.; Ito, Yasushi; Dorothy, Fredric W.; Shih, Alan M.; Peugeot, John
2010-01-01
Fluid flow simulations through a valve often require evaluation of the valve in multiple opening positions. A mesh has to be generated for the valve for each position and compounding. The problem is the fact that the valve is typically part of a larger feedline system. In this paper, we propose to develop a system to create meshes for feedline systems with parametrically controlled valve openings. Herein we outline two approaches to generate the meshes for a valve in a feedline system at multiple positions. There are two issues that must be addressed. The first is the creation of the mesh on the valve for multiple positions. The second is the generation of the mesh for the total feedline system including the valve. For generation of the mesh on the valve, we will describe the use of topology matching and mesh generation parameter transfer. For generation of the total feedline system, we will describe two solutions that we have implemented. In both cases the valve is treated as a component in the feedline system. In the first method the geometry of the valve in the feedline system is replaced with a valve at a different opening position. Geometry is created to connect the valve to the feedline system. Then topology for the valve is created and the portion of the topology for the valve is topology matched to the standard valve in a different position. The mesh generation parameters are transferred and then the volume mesh for the whole feedline system is generated. The second method enables the user to generate the volume mesh on the valve in multiple open positions external to the feedline system, to insert it into the volume mesh of the feedline system, and to reduce the amount of computer time required for mesh generation because only two small volume meshes connecting the valve to the feedline mesh need to be updated.
FLUID MECHANICS OF ARTIFICIAL HEART VALVES
Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P
2009-01-01
SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329
Fluid mechanics of artificial heart valves.
Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P
2009-02-01
1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.
Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.
Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa
2016-03-01
A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.
Accuracy assessment of fluoroscopy-transesophageal echocardiography registration
NASA Astrophysics Data System (ADS)
Lang, Pencilla; Seslija, Petar; Bainbridge, Daniel; Guiraudon, Gerard M.; Jones, Doug L.; Chu, Michael W.; Holdsworth, David W.; Peters, Terry M.
2011-03-01
This study assesses the accuracy of a new transesophageal (TEE) ultrasound (US) fluoroscopy registration technique designed to guide percutaneous aortic valve replacement. In this minimally invasive procedure, a valve is inserted into the aortic annulus via a catheter. Navigation and positioning of the valve is guided primarily by intra-operative fluoroscopy. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to heart valve embolization, obstruction of the coronary ostia and acute kidney injury. The use of TEE US images to augment intra-operative fluoroscopy provides significant improvements to image-guidance. Registration is achieved using an image-based TEE probe tracking technique and US calibration. TEE probe tracking is accomplished using a single-perspective pose estimation algorithm. Pose estimation from a single image allows registration to be achieved using only images collected in standard OR workflow. Accuracy of this registration technique is assessed using three models: a point target phantom, a cadaveric porcine heart with implanted fiducials, and in-vivo porcine images. Results demonstrate that registration can be achieved with an RMS error of less than 1.5mm, which is within the clinical accuracy requirements of 5mm. US-fluoroscopy registration based on single-perspective pose estimation demonstrates promise as a method for providing guidance to percutaneous aortic valve replacement procedures. Future work will focus on real-time implementation and a visualization system that can be used in the operating room.
Seki, Tatsuya; Hattori, Atsuo; Yoshida, Toshihito
2017-08-01
We report a case of hemodynamic deterioration after aortic valve replacement in a patient with mixed systemic amyloidosis. A 77-year-old male with severe aortic valve stenosis and 19 years hemodialysis underwent aortic valve replacement. Postoperatively, the patient died of hemodynamic deterioration. Autopsy findings showed massive, whole-body edema and mixed systemic amyloidosis (dialysis-related and AA amyloidosis). Clinical and autopsy findings implied that hemodynamic deterioration was caused by increased vascular permeability. The amyloid deposit to the vessel causes inflammatory changes and increases vascular permeability. Mixed systemic amyloidosis occurs very rarely and could increases vascular permeability even more than each single type of amyloidosis. Systemic amyloidosis may be a risk factor for hemodynamic deterioration after cardiac surgery. Patients with longtime hemodialysis and a history associated with dialysis-related amyloidosis would have at least single systemic amyloidosis, which should be considered a contraindication to cardiac surgery with cardiopulmonary bypass.
[Tricuspid valve insufficiency: what should be done?].
von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G
1998-12-01
Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.
O'Neil, C R; Taylor, G; Smith, S; Joffe, A M; Antonation, K; Shafran, S; Kunimoto, D
2018-02-01
We present a case of Mycobacterium chimaera infection presenting with aortic dissection and pseudoaneuysm in a 22-year-old man with a past history of aortic valve replacement. Clinicians should consider M. chimaera infection in those presenting with aortic dissection as a late complication of cardiovascular surgery.
Crawshaw, Jacob; Rimington, Helen; Weinman, John; Chilcot, Joseph
2015-10-01
The aim of the present study was to examine whether profiles of illness perceptions are associated with 10-year survival following cardiac valve replacement surgery. Illness perceptions were evaluated in 204 cardiac patients awaiting first-time valve replacement and again 1 year post-operatively using cluster analysis. All-cause mortality was recorded over a 10-year period. At 1 year, 136 patients were grouped into one of four profiles (stable positive, stable negative, changed from positive to negative, changed from negative to positive). The median follow-up was 3063 days (78 deaths). After controlling for clinical covariates, including markers of function, patients who changed illness perceptions from positive to negative beliefs 1 year post-surgery had an increased mortality risk (hazard ratio (HR) = 3.2, 95% confidence interval (CI) 1.2-8.3, p = .02) compared to patients who held positive stable perceptions. Following cardiac valve replacement, developing negative illness perceptions over the first post-operative year predicts long-term mortality. Early screening and intervention to alter this pattern of beliefs may be beneficial.
Valve-sparing aortic root replacement in Loeys-Dietz syndrome.
Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A
2011-08-01
Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
One-year outcome following biological or mechanical valve replacement for infective endocarditis.
Delahaye, F; Chu, V H; Altclas, J; Barsic, B; Delahaye, A; Freiberger, T; Gordon, D L; Hannan, M M; Hoen, B; Kanj, S S; Lejko-Zupanc, T; Mestres, C A; Pachirat, O; Pappas, P; Lamas, C; Selton-Suty, C; Tan, R; Tattevin, P; Wang, A
2015-01-15
Nearly half of patients require cardiac surgery during the acute phase of infective endocarditis (IE). We describe the characteristics of patients according to the type of valve replacement (mechanical or biological), and examine whether the type of prosthesis was associated with in-hospital and 1-year mortality. Among 5591 patients included in the International Collaboration on Endocarditis Prospective Cohort Study, 1467 patients with definite IE were operated on during the active phase and had a biological (37%) or mechanical (63%) valve replacement. Patients who received bioprostheses were older (62 vs 54years), more often had a history of cancer (9% vs 6%), and had moderate or severe renal disease (9% vs 4%); proportion of health care-associated IE was higher (26% vs 17%); intracardiac abscesses were more frequent (30% vs 23%). In-hospital and 1-year death rates were higher in the bioprosthesis group, 20.5% vs 14.0% (p=0.0009) and 25.3% vs 16.6% (p<.0001), respectively. In multivariable analysis, mechanical prostheses were less commonly implanted in older patients (odds ratio: 0.64 for every 10years), and in patients with a history of cancer (0.72), but were more commonly implanted in mitral position (1.60). Bioprosthesis was independently associated with 1-year mortality (hazard ratio: 1.298). Patients with IE who receive a biological valve replacement have significant differences in clinical characteristics compared to patients who receive a mechanical prosthesis. Biological valve replacement is independently associated with a higher in-hospital and 1-year mortality, a result which is possibly related to patient characteristics rather than valve dysfunction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
The impact of the metabolic syndrome on the outcome after aortic valve replacement.
Tadic, Marijana; Vukadinovic, Davor; Cvijanovic, Dane; Celic, Vera; Kocica, Mladen; Putnik, Svetozar; Ivanovic, Branislava
2014-10-01
The aim of this study was to examine the influence of the metabolic syndrome on the left ventricular geometry as well as on the early and mid-time outcome in patients with aortic stenosis who underwent aortic valve replacement. The study included 182 patients who underwent aortic valve replacement due to aortic stenosis. The metabolic syndrome was defined by the presence of at least three AHA-NHLB (American Heart Association/National Heart, Lung and Blood Institute) criteria. All the patients were followed for at least 2 years after the surgery. The metabolic syndrome did not influence the severity of aortic stenosis (mean gradient and aortic valve area). However, the metabolic syndrome was associated with the reduced prevalence of the normal left ventricular geometry and the increased risk of concentric left ventricular hypertrophy in patients with aortic stenosis. Among the metabolic syndrome criteria, only increased blood pressure was simultaneously associated with the short-term and mid-term outcome, independently of other risk factors. Increased fasting glucose level was an independent predictor of the only 30-day outcome after the valve replacement. The metabolic syndrome and left ventricular hypertrophy were, independently of hypertension and diabetes, associated with the 30-day outcome, as well as incidence of major cerebrovascular and cardiovascular events in the 2-year postoperative period. The metabolic syndrome does not change severity of the aortic stenosis, but significantly impacts the left ventricular remodeling in these patients. The metabolic syndrome and left ventricular hypertrophy, irrespective of hypertension and diabetes, are predictors of the short-term and mid-term outcome of patients with aortic stenosis who underwent aortic valve replacement.
Scharfschwerdt, Michael; Leonhard, Moritz; Lehmann, Judith; Richardt, Doreen; Goldmann, Helmut; Sievers, Hans-Hinrich
2016-05-01
Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular prosthesis providing elastic behaviours. In a first series (n = 14), haemodynamics and leaflet motions of the aortic valve were investigated and also cyclic changes of aortic dimensions at different levels of the root. In a second series (n = 7), intravascular pressure and dimensions of the proximal descending aorta were measured and the corresponding wall tension was calculated. Haemodynamics of the aortic valve remain comparable after replacement. Though the novel prosthesis does not feature such high distensibility as the native aorta, the dynamic of the root was significantly increased compared with common Dacron prostheses at the commissural level, preserving 'windkessel' function. Thus, wall tension of the residual aorta remained unchanged; nevertheless, maximum pressure-time differential dp/dt increased by 13%. The use of the novel elastic prosthesis for replacement of the ascending aorta seems to be beneficial, especially with regard to the preservation of the aortic windkessel. Further studies will be needed to clarify long-term utilization of the material in vivo. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Vaquerizo, Beatriz; Theriault-Lauzier, Pascal; Piazza, Nicolo
2015-12-01
Mitral regurgitation is the most prevalent valvular heart disease worldwide. Despite the widespread availability of curative surgical intervention, a considerable proportion of patients with severe mitral regurgitation are not referred for treatment, largely due to the presence of left ventricular dysfunction, advanced age, and comorbid illnesses. Transcatheter mitral valve replacement is a promising therapeutic alternative to traditional surgical valve replacement. The complex anatomical and pathophysiological nature of the mitral valvular complex, however, presents significant challenges to the successful design and implementation of novel transcatheter mitral replacement devices. Patient-specific 3-dimensional computer-based models enable accurate assessment of the mitral valve anatomy and preprocedural simulations for transcatheter therapies. Such information may help refine the design features of novel transcatheter mitral devices and enhance procedural planning. Herein, we describe a novel medical image-based processing tool that facilitates accurate, noninvasive assessment of the mitral valvular complex, by creating precise three-dimensional heart models. The 3-dimensional computer reconstructions are then converted to a physical model using 3-dimensional printing technology, thereby enabling patient-specific assessment of the interaction between device and patient. It may provide new opportunities for a better understanding of the mitral anatomy-pathophysiology-device interaction, which is of critical importance for the advancement of transcatheter mitral valve replacement. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Kyo, S; Miyamoto, N; Yokote, Y; Ueda, K; Takamoto, S; Omoto, R
1996-06-01
Complete rupture of a papillary muscle following acute myocardial infarction is a severe complication that is typically associated with acute left ventricular failure, pulmonary edema, and relentless clinical deterioration. The reported mortality rates without surgical intervention is almost 90%, therefore, prompt operation without prolonged attempts at medical stabilization is the key to decrease operative mortality. Although the complete coronary revascularization in conjunction with mitral valve replacement is advocated in the western medical academic society, there is only a few case of conjunct surgery has been reported in Japan. Three successful cases of conjunct surgery of mitral valve replacement and coronary complete revascularization in acute phase within one week from the onset of acute myocardial infarction (AMI) are described. There were one male and two female patients with an average age of 60-year-old (range 48-67), who developed cardiogenic shock and admitted to our hospital. The average interval between onset of AMI and the appearance of mitral regurgitation (MR) was 38 hours, and that of the appearance of MR and admission was 40 hours. Surgeries were performed within 26 hours (average 13 hours) after admission. The mitral valve was replaced with a mechanical valve (St. Jude Medical Valve) and a complete coronary revasculatization was done using saphenous vein graft. The average period of operation time and aortic cross clamping time were 6 hours 22 minutes and 109 minutes respectively. The average number of coronary grafting was 2.3 (range 1-3). Postoperative recovery from cardiogenic shock was uneventful in all three patients. The average periods of ICU stay and hospital stay were 5 days and 43 days respectively. All patients have regained their social activities with mean follow up period of 52 months. Since ischemic heart disease remains the leading cause of death in such patients, it is suggested that complete coronary revascularization should be performed immediately in conjunction with valve replacement even in the acute phase after onset of AMI.
Early and late outcomes of 1000 minimally invasive aortic valve operations.
Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F
2008-04-01
Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.
Chi, Hao; Zhou, Wen-Xiong; Wu, Yao-Yao; Chen, Tong-Yu; Ge, Wen; Yuan, Lan; Shen, Wei-Dong; Zhou, Jia
2014-02-01
To determine whether electroacupuncture (EA) intervention combined with general anesthesia (GA) strategy can reduce early post-operative morbidity and medical costs in patients undergoing heart valve replacement operation under cardiopulmonary bypass. A total of 160 heart valve replacement surgery patients undergoing cardiopulmonary bypass were randomly divided into GA and EA + GA groups (n = 80 in each group). Patients of the GA group were given with intravenous injection of Fentanyl, Midazolam, Vecuronium Bromide, etc. and routine tracheal intubation. EA (3-4 Hz, 2.0-2.2 mA) was applied to bilateral Zhongfu (LU 1), Chize (LU 5) and Ximen (PC 4) beginning about 20 mm before the surgery in the EA + GA group. Endotracheal intubation was not employed but only prepared as a standby for patients of the EA + GA group. The dosage of narcotic drugs, duration of surgery, duration of aertic blockage, rate of cardiac re-beating, volumes of post-operative blood transfusion, discharge volume, cases of post-operative pulmonary infection, vocal cord injury, and the time of first bed-off, first eating and duration in intensive care unit (IOU) residence. etc. were recorded. The successful rates of heart valve replacement surgery were similar in both GA and EA + GA groups. Compared with the GA group, the dosages of Fentanyl, Midazolam and Vecuronium of the EA + GA group were significantly lower (P < 0.05, P < 0.01), the numbers of patients needing blood-transfusion, antibiotics treatment, and suffering from pulmonary infection were fewer, the time of first bed-off and duration of hospitalizetion and IOU residence were considerably shorter (P < 0.05, P < 0.01) and the total medical cost was obviously lower (P < 0.05) in the EA + GA group. EA combined with general anesthesia strategy for heart valve replacement surgery without endotracheal intubation is safe and can reduce post-operative morbidity and medical costs in patients undergoing heart valve replacement surgery under cardiopulmonary bypass.
Sierad, Leslie Neil; Shaw, Eliza Laine; Bina, Alexander; Brazile, Bryn; Rierson, Nicholas; Patnaik, Sourav S.; Kennamer, Allison; Odum, Rebekah; Cotoi, Ovidiu; Terezia, Preda; Branzaniuc, Klara; Smallwood, Harrison; Deac, Radu; Egyed, Imre; Pavai, Zoltan; Szanto, Annamaria; Harceaga, Lucian; Suciu, Horatiu; Raicea, Victor; Olah, Peter; Simionescu, Agneta; Liao, Jun; Movileanu, Ionela
2015-01-01
There is a great need for living valve replacements for patients of all ages. Such constructs could be built by tissue engineering, with perspective of the unique structure and biology of the aortic root. The aortic valve root is composed of several different tissues, and careful structural and functional consideration has to be given to each segment and component. Previous work has shown that immersion techniques are inadequate for whole-root decellularization, with the aortic wall segment being particularly resistant to decellularization. The aim of this study was to develop a differential pressure gradient perfusion system capable of being rigorous enough to decellularize the aortic root wall while gentle enough to preserve the integrity of the cusps. Fresh porcine aortic roots have been subjected to various regimens of perfusion decellularization using detergents and enzymes and results compared to immersion decellularized roots. Success criteria for evaluation of each root segment (cusp, muscle, sinus, wall) for decellularization completeness, tissue integrity, and valve functionality were defined using complementary methods of cell analysis (histology with nuclear and matrix stains and DNA analysis), biomechanics (biaxial and bending tests), and physiologic heart valve bioreactor testing (with advanced image analysis of open–close cycles and geometric orifice area measurement). Fully acellular porcine roots treated with the optimized method exhibited preserved macroscopic structures and microscopic matrix components, which translated into conserved anisotropic mechanical properties, including bending and excellent valve functionality when tested in aortic flow and pressure conditions. This study highlighted the importance of (1) adapting decellularization methods to specific target tissues, (2) combining several methods of cell analysis compared to relying solely on histology, (3) developing relevant valve-specific mechanical tests, and (4) in vitro testing of valve functionality. PMID:26467108
D'Amore, Antonio; Luketich, Samuel K; Raffa, Giuseppe M; Olia, Salim; Menallo, Giorgio; Mazzola, Antonino; D'Accardi, Flavio; Grunberg, Tamir; Gu, Xinzhu; Pilato, Michele; Kameneva, Marina V; Badhwar, Vinay; Wagner, William R
2018-01-01
Valvular heart disease is currently treated with mechanical valves, which benefit from longevity, but are burdened by chronic anticoagulation therapy, or with bioprosthetic valves, which have reduced thromboembolic risk, but limited durability. Tissue engineered heart valves have been proposed to resolve these issues by implanting a scaffold that is replaced by endogenous growth, leaving autologous, functional leaflets that would putatively eliminate the need for anticoagulation and avoid calcification. Despite the diversity in fabrication strategies and encouraging results in large animal models, control over engineered valve structure-function remains at best partial. This study aimed to overcome these limitations by introducing double component deposition (DCD), an electrodeposition technique that employs multi-phase electrodes to dictate valve macro and microstructure and resultant function. Results in this report demonstrate the capacity of the DCD method to simultaneously control scaffold macro-scale morphology, mechanics and microstructure while producing fully assembled stent-less multi-leaflet valves composed of microscopic fibers. DCD engineered valve characterization included: leaflet thickness, biaxial properties, bending properties, and quantitative structural analysis of multi-photon and scanning electron micrographs. Quasi-static ex-vivo valve coaptation testing and dynamic organ level functional assessment in a pressure pulse duplicating device demonstrated appropriate acute valve functionality. Copyright © 2017. Published by Elsevier Ltd.
Outcomes After Operations for Unicuspid Aortic Valve With or Without Ascending Repair in Adults
Zhu, Yuanjia; Roselli, Eric E.; Idrees, Jay J.; Wojnarski, Charles M.; Griffin, Brian; Kalahasti, Vidyasagar; Pettersson, Gosta; Svensson, Lars G.
2016-01-01
Background Unicuspid aortic valve is an important subset of bicuspid aortic valve, and knowledge regarding its aortopathy pattern and surgical outcomes is limited. Our objectives were to characterize unicuspid aortic valve patients, associated aortopathy, and surgical outcomes. Methods From January 1990 to May 2013, 149 adult unicuspid aortic valve patients underwent aortic valve replacement or repair for aortic stenosis (n = 13), regurgitation (n = 13), or both (n = 123), and in 91 (61%) the aortic valve operation was combined with aortic repair. Data were obtained from the Cardiovascular Information Registry and medical record review. Three-dimensional imaging analysis was performed from preoperative computed tomography and magnetic resonance imaging scans. The Kaplan-Meier method was used for survival analysis. Results Patients had a mean maximum aortic diameter of 44 ± 8 mm and variably involved the aortic root, ascending, or arch, or both. Patients with valve operations alone were more likely to be hypertensive (p = 0.01) and to have severe aortic stenosis (p = 0.07) than those who underwent concurrent aortic operations. There were no operative deaths, strokes, or myocardial infarctions. Patients undergoing aortic repair had better long-term survival. Estimated survival at 1, 5, and 10 years was 100%, 100%, and 100% after combined operations and was 100%, 88%, and 88% after valve operations alone (p = 0.01). Conclusions Patients with a dysfunctional unicuspid aortic valve frequently present with an ascending aneurysm that requires repair. Combined aortic valve operations and aortic repair was associated with significantly better long-term survival than a valve operation alone. Further study of this association may direct decisions about timing of surgical intervention. PMID:26453423
Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo
2018-05-15
Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.
Bonios, Michael J; Selzman, Craig H; Gilbert, Edward M; McKellar, Stephen H; Koliopoulou, Antigoni; Strege, Jennifer L; Nativi, Jose N; Fang, James C; Stehlik, Josef; Drakos, Stavros G
We present the case of two patients with idiopathic dilated cardiomyopathy and moderate aortic valve regurgitation that were treated with a bioprosthetic valve at the time of the left ventricular assist device (LVAD) implantation. A few months later, patients revealed partial recovery in the left ventricle systolic function. Both patients, during the LVAD turndown protocol, reported the onset of chest pain. The transthoracic echocardiography revealed the presence of a new transaortic pressure gradient. We confirmed the presence of a fused bioprosthetic valve by further performing a transesophageal echocardiogram and a left and right heart catheterization. Replacement of aortic valve at the time of an LVAD implantation constitutes a challenging case. Although a mechanical valve is contraindicated due to the increased thromboembolic risk, selecting a bioprosthetic valve increases the risk of valve leaflets fusion. The consequences of this phenomenon should be acknowledged in LVAD patients undergoing aortic valve replacement with a bioprosthetic, especially under the view of LVAD explantation for those revealing myocardial recovery under mechanical unloading.
Kasel, Albert M; Shivaraju, Anupama; Schneider, Stephan; Krapf, Stephan; Oertel, Frank; Burgdorf, Christof; Ott, Ilka; Sumer, Christian; Kastrati, Adnan; von Scheidt, Wolfgang; Thilo, Christian
2014-09-01
To provide a simplified, standardized methodology for a successful transfemoral transcatheter aortic valve replacement (TAVR) procedure with the Sapien XT valve in patients with severe aortic stenosis (AS). TAVR is currently reserved for patients with severe, symptomatic AS who are inoperable or at high operative risk. In many institutions, TAVR is performed under general anesthesia with intubation or with conscious sedation. In addition, many institutions still use transesophageal echo (TEE) during the procedure for aortic root angulations and positioning of the valve prior to implantation. Methods. We enrolled 100 consecutive patients (mean age, 80 ± 7 years; range, 50-94 years; female n=59) with severe symptomatic AS. Annulus measurements were based on computed tomography angiograms. All patients underwent fluoroscopy-guided transfemoral TAVR with little to no sedation and without simultaneous TEE. TAVR was predominantly performed with the use of local and central analgesics; only 36% of our cohort received conscious sedation. Procedural success of TAVR was 99%. Transthoracic echocardiography before discharge excluded aortic regurgitation (AR) >2 in all patients (AR >1; n=6). In-hospital stroke rate was 6%. The vessel closure system was successfully employed in 96%. Major vascular complication rate was 1%. The 30-day mortality was 2%. Fluoroscopy-guided TAVR with the use of just analgesics with or without conscious sedation is safe and effective, and this potentially enables a more time-effective and cost-effective procedure. This paper provides simplified, stepwise guidance on how to perform transfemoral TAVR with the Sapien XT valve.
Meyer, Chloe Grace; Vacek, Thomas Paul; Bansal, Amit; Gurujal, Ravi; Parikh, Analkumar
2018-01-01
This report illustrates a case of a 42-year-old male with a history of intravenous drug abuse who presented with septic shock. Diagnostic studies, including a transthoracic echocardiogram, chest computed tomography angiography, transesophageal echocardiogram, and blood cultures ultimately revealed Serratia marcescens pulmonic valve infective endocarditis that was treated with intravenous antibiotics. In addition to the rare form of endocarditis and bacterium involved, this case brings into awareness the dynamic nature of the hospital course that requires vigilance in responding to hypotensive episodes for consideration of pulmonary embolism. Surgical valve replacement was opted for due to such a complication in addition to the large size of the vegetation, 2.5 cm.
Coselli, Joseph S; Volguina, Irina V; LeMaire, Scott A; Sundt, Thoralf M; Connolly, Heidi M; Stephens, Elizabeth H; Schaff, Hartzell V; Milewicz, Dianna M; Vricella, Luca A; Dietz, Harry C; Minard, Charles G; Miller, D Craig
2014-06-01
To compare the 1-year results after aortic valve-sparing (AVS) or valve-replacing (AVR) aortic root replacement from a prospective, international registry of 316 patients with Marfan syndrome (MFS). Patients underwent AVS (n = 239, 76%) or AVR (n = 77, 24%) aortic root replacement at 19 participating centers from 2005 to 2010. One-year follow-up data were complete for 312 patients (99%), with imaging findings available for 293 (94%). The time-to-events were compared between groups using Kaplan-Meier curves and Cox proportional hazards models. Two patients (0.6%)--1 in each group--died within 30 days. No significant differences were found in early major adverse valve-related events (MAVRE; P = .6). Two AVS patients required early reoperation for coronary artery complications. The 1-year survival rates were similar in the AVR (97%) and AVS (98%) groups; the procedure type was not significantly associated with any valve-related events. At 1 year and beyond, aortic regurgitation of at least moderate severity (≥2+) was present in 16 patients in the AVS group (7%) but in no patients in the AVR group (P = .02). One AVS patient required late AVR. AVS aortic root replacement was not associated with greater 30-day mortality or morbidity rates than AVR root replacement. At 1 year, no differences were found in survival, valve-related morbidity, or MAVRE between the AVS and AVR groups. Of concern, 7% of AVS patients developed grade ≥2+ aortic regurgitation, emphasizing the importance of 5 to 10 years of follow-up to learn the long-term durability of AVS versus AVR root replacement in patients with MFS. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
... Bases and replacing the isolation time with the phase, ``within limits.'' The proposed change does not... isolation valves are retained in the TS. Future changes to the Bases or licensee-controlled document will be... referenced in the Bases. In addition, the valve isolation times are replaced in the TS with the phase...
Diesel Goes Digital to Save Energy, Lower Emissions
NASA Technical Reports Server (NTRS)
2004-01-01
Forty years ago, actuators requiring constant energy to help power the Apollo spacecraft in space were replaced by magnetically holding and releasing, electronically controlled valves. Today, these same magnetic, electronic valves are on the verge of replacing entire camshaft systems in cars and trucks on Earth, thus leading to a whole new generation of low-emission engines.
Aortic valve replacement and repair of left ventricular pseudoaneurysm in a Jehovah’s Witness
Perrotti, Andrea; Vaislic, Claude; Chocron, Sidney
2013-01-01
The preoperative and surgical management of a giant left ventricular pseudoaneurysm(LVP) associated with aortic valve replacement in a 76 year old male Jehovah’s Witness patient is reported. The satisfactory recovery observed in this patient demonstrates the feasibility of this complex surgical procedure even in this particular patient population. PMID:25478494
Chikkabyrappa, Sathish; Mosca, Ralph S; McElhinney, Doff B
2016-06-01
We report a case of retrograde transcatheter device closure of a complex paravalvular leak (PVL) after bioprosthetic pulmonary valve replacement (PVR) in a 13-year-old patient with congenital pulmonary valve stenosis. There are prior reports of pulmonary PVL closure after PVR in adults (Seery and Slack, Congenit Heart Dis 2014;9:E19-F22), but indications for and technical considerations in PVL closure after bioprosthetic PVR, particularly in children, are not well defined. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Coronary ostia obstruction after replacement of aortic valve prostesis
2011-01-01
Aortic valve replacement (AVR) is the gold standard for the treatment of severe symptomatic aortic stenosis. Complications directly related to surgical procedure are relatively infrequent. Coronary ostial stenosis is, generally, referred as late complication. Anecdotal reports concern coronary ostial stenosis as acute complication. A unique fatal case of intraoperative, bilateral coronary ostial obstruction by prosthetic valve leading to an extensive myocardial infarction is reported. Surgeons must have a high level of vigilance regarding the occurrence of acute myocardial ischemia and sudden death soon after AVR. PMID:21810231
Minimally invasive aortic valve replacement – pros and cons of keyhole aortic surgery
Szałański, Przemysław; Zembala, Michał; Filipiak, Krzysztof; Karolak, Wojciech; Wojarski, Jacek; Garbacz, Marcin; Kaczmarczyk, Aleksandra; Kwiecień, Anna; Zembala, Marian
2015-01-01
Over the last twenty years, minimally invasive aortic valve replacement (MIAVR) has evolved into a safe, well-tolerated and efficient surgical treatment option for aortic valve disease. It has been shown to reduce postoperative morbidity, providing faster recovery and rehabilitation, shorter hospital stay and better cosmetic results compared with conventional surgery. A variety of minimally invasive accesses have been developed and utilized to date. This concise review demonstrates and discusses surgical techniques used in contemporary approaches to MIAVR and presents the most important results of MIAVR procedures. PMID:26336491
Tsai, I-Chen; Lin, Yung-Kai; Chang, Yen; Fu, Yun-Ching; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen; Jan, Sheng-Ling; Wang, Kuo-Yang; Chen, Min-Chi; Chen, Clayton Chi-Chang
2009-04-01
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.
Durability of hand-sewn valves in the right ventricular outlet.
Nunn, Graham R; Bennetts, Jayme; Onikul, Ella
2008-08-01
The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained competent with regurgitant fractions of only 5% to 30% (magnetic resonance imaging angiography), and this has remained stable with time. The maximum follow-up for these valves is 5 years. No stenosis or peripheral emboli have been recognized, and no valves have been replaced to date. Hand-sewn bileaflet polytetrafluoroethylene valves in the right ventricular outlet can reliably provide competence and maintain function in the medium term. Their shape and size allow placement in young children with a reasonable expectation that they will remain competent with growth of the native annulus and not require replacement. Their durability is superior to the pericardial and polytetrafluoroethylene monocusp valves in this series.
Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael
2017-07-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.
Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin
2015-01-01
Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380
Pros and cons of transcatheter aortic valve implantation (TAVI).
Terré, Juan A; George, Isaac; Smith, Craig R
2017-09-01
Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.
[Tricuspid valve regurgitation : Indications and operative techniques].
Lange, R; Piazza, N; Günther, T
2017-11-01
Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.
Park, Byungjoon; Sung, Kiick; Park, Pyo Won
2018-01-25
This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (P<0.001). No mechanical valve malfunction was apparent on last echocardiography. TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.
Hybrid textile heart valve prosthesis: preliminary in vitro evaluation.
Vaesken, Antoine; Pidancier, Christian; Chakfe, Nabil; Heim, Frederic
2016-09-22
Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.
Popma, Jeffrey J; Adams, David H; Reardon, Michael J; Yakubov, Steven J; Kleiman, Neal S; Heimansohn, David; Hermiller, James; Hughes, G Chad; Harrison, J Kevin; Coselli, Joseph; Diez, Jose; Kafi, Ali; Schreiber, Theodore; Gleason, Thomas G; Conte, John; Buchbinder, Maurice; Deeb, G Michael; Carabello, Blasé; Serruys, Patrick W; Chenoweth, Sharla; Oh, Jae K
2014-05-20
This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery. Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effective therapy. We performed a prospective, multicenter, nonrandomized investigation evaluating the safety and efficacy of self-expanding TAVR in patients with symptomatic severe aortic stenosis with prohibitive risks for surgery. The primary endpoint was a composite of all-cause mortality or major stroke at 12 months, which was compared with a pre-specified objective performance goal (OPG). A total of 41 sites in the United States recruited 506 patients, of whom 489 underwent attempted treatment with the CoreValve THV. The rate of all-cause mortality or major stroke at 12 months was 26.0% (upper 2-sided 95% confidence bound: 29.9%) versus 43.0% with the OPG (p < 0.0001). Individual 30-day and 12-month events included all-cause mortality (8.4% and 24.3%, respectively) and major stroke (2.3% and 4.3%, respectively). Procedural events at 30 days included life-threatening/disabling bleeding (12.7%), major vascular complications (8.2%), and need for permanent pacemaker placement (21.6%). The frequency of moderate or severe paravalvular aortic regurgitation was lower 12 months after self-expanding TAVR (4.2%) than at discharge (10.7%; p = 0.004 for paired analysis). TAVR with a self-expanding bioprosthesis was safe and effective in patients with symptomatic severe aortic stenosis at prohibitive risk for surgical valve replacement. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A timed solenoid injector for flow analysis.
Rothwell, S D; Woolf, A A
1985-05-01
Samples can be reproducibly injected into flow-streams by timed switching of a sample stream with a miniature solenoid valve and timer circuit. The device is simpler to assemble and use than the standard rotary valve and a direct comparison under the same operating conditions shows that the solenoid valve is an adequate replacement for the rotary valve.
Liquid-fuel valve with precise throttling control
NASA Technical Reports Server (NTRS)
Mcdougal, A. R.; Porter, R. N.; Riebling, R. W.
1971-01-01
Prototype liquid-fuel valve performs on-off and throttling functions in vacuum without component cold-welding or excessive leakage. Valve design enables simple and rapid disassembly and parts replacement and operates with short working stroke, providing maximum throttling sensitivity commensurate with good control.
Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.
Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi
2013-09-10
Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.
Aortic root remodeling: ten-year experience with 274 patients.
Aicher, Diana; Langer, Frank; Lausberg, Henning; Bierbach, Benjamin; Schäfers, Hans-Joachim
2007-10-01
Dilatation of the aortic root with concomitant aortic regurgitation can be treated by valve-preserving surgery. We have consistently chosen root remodeling rather than reimplantation whenever the aortoventricular junction was not dilated. We have analyzed our 11-year experience with root remodeling. Between October 1995 and October 2006, 274 patients (201 male; 73 female, aged 59 +/- 15 years) were treated by root remodeling in the presence of a preserved aortoventricular diameter (<30 mm). Acute aortic dissection was present in 46 patients. The valve anatomy was tricuspid in 193 and bicuspid in 81 patients. Cusp disease was additionally corrected in 173 (63%) patients. Follow-up was complete in 99%. Cumulative follow-up was 1045 patient-years (mean of 4.0 +/- 2.7 years). Hospital mortality was 3.6% (elective 3.1%; emergency 6.5%). One patient had endocarditis 2 months postoperatively and subsequently underwent valve replacement. Freedom from aortic regurgitation of grade II or more was 91% and 87% at 10 years for bicuspid and tricuspid aortic valves. Nine patients required reoperation: in 6 patients the valve was replaced and in 3 patients rerepaired. Freedom from reoperation was 96% at 5 and 10 years, and freedom from valve replacement was 98% at 5 and 10 years. A comparison of 3 operative periods (1995-1998, 1999-2002, and 2003-2006) showed that with increasing experience cusp prolapse was diagnosed and corrected more frequently (8/49 = 17%; 62/105 = 59%; 103/108 = 82%; P < .0001), and repair stability significantly improved over time (P = .007). Root remodeling leads to durable restoration of aortic valve function in both tricuspid and bicuspid valve anatomy. Aggressive correction of cusp prolapse seems to have a beneficial effect on aortic valve competence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav
Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less
Luciani, G B; Bertolini, P; Vecchi, B; Mazzucco, A
1998-06-01
The ideal substitute for the diseased aortic valve is yet to be found. For the assessment and comparison of the midterm results after aortic valve replacement with three different types of freehand stentless xenografts, all patients who underwent the operation between October 1992 and April 1997 were reviewed. Of 231 patients undergoing aortic valve replacement, 106 patients (group 1) were given the Biocor PSB (Biocor Industria e Pesquisa Ltda, Belo Horizonte, MG, Brazil); 76 patients (group 2) were given the Toronto SPV (St. Jude Medical, Inc., St. Paul, Minn.), and 49 patients (group 3) were given the O'Brien-Angell valve (Bravo Cardiovascular model 300, Cryolife, Inc., Marietta, Ga.). The first two xenografts require inflow and outflow suturelines; the third xenograft needs a single-sutureline implantation. Mean age (70 +/- 6 years; 70 +/- 7 years; 72 +/- 9 years; p = 0.6), prevalence of male sex (56 patients, 53%; 37 patients, 49%; 22 patients, 45%; p = 0.7), of aortic stenosis (72 patients, 68%; 54 patients, 71%; 37 patients, 73%; p = 0.6), and need for associated procedures (51 patients, 48%; 30 patients, 40%; 21 patients, 43%; p = 0.1) were comparable among groups. Mean aortic crossclamp time was shorter in group 3 (96 +/- 24 minutes; 100 +/- 23 minutes; 88 +/- 25 minutes;p = 0.01). Early deaths were 3 of 106 (3%) in group 1, 2 of 76 (3%) in group 2, and 2 of 49 (4%) in group 3. Follow-up of survivors ranged from 1 to 54 months (mean 32 +/- 13 months). Survival at 4 years was 90% +/- 3% in group 1, 95% +/- 3% in group 2, 85% +/- 8% in group 3 (p = 0.3). At 4 years, freedom from valve-related events was 95% +/- 6%, 100%, 70% +/- 8% (p = 0.004), while freedom from valve deterioration was 99% +/- 1%, 100%, 73% +/- 8% (p = 0.001), in group 1, 2, and 3, respectively (p = 0.001). At follow-up, reintervention on the xenograft was necessary in one patient (endocarditis) in group 1, none in group 2, and six in group 3 (technical cause, group 3; valve tear, group 2; pannus, group 1). Regression analysis showed O'Brien-Angell type of xenograft to be predictive of valve-related events (p = 0.02), valve deterioration (p = 0.001), and reoperation (p = 0.001) during follow-up. Midterm survival after stentless aortic valve replacement is good with all three xenografts. Freedom from valve-related events, valve deterioration, and reoperation are excellent with the Biocor PSB or the Toronto SPV stentless valves but less satisfactory with the O'Brien-Angell valve.
Coronary artery compression by teflon pledget granuloma following aortic valve replacement.
Cohle, S D; Delavan, J W
1997-09-01
We describe a massive fatal posterior myocardial infarct resulting from compression of the right coronary artery by a Teflon pledget granuloma in a patient who had undergone aortic valve replacement six months before death. Other iatrogenic causes of coronary artery occlusion or compression are discussed in this paper. To our knowledge this is the first report of this surgical complication.
Garg, Aatish; Parashar, Akhil; Agarwal, Shikhar; Aksoy, Olcay; Hammadah, Muhammad; Poddar, Kanhaiya Lal; Puri, Rishi; Svensson, Lars G; Krishnaswamy, Amar; Tuzcu, E Murat; Kapadia, Samir R
2015-02-15
The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.
Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A
Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P < 0.001). Pressures outside adjacent sutures (extrasuture) were less than 80 mm Hg in 10 of 60 HT, zero of 60 KP, and zero of 120 TF sites for 15 × 4-mm valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P < 0.001 all manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.
Myers, Patrick O; Cikirikcioglu, Mustafa; Kalangos, Afksendiyos
2014-08-03
One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, "vanishing" material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis.
2014-01-01
Background One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, “vanishing” material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Discussion Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. Summary These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis. PMID:25087015
The Economics of Transcatheter Valve Interventions.
Sud, Maneesh; Tam, Derrick Y; Wijeysundera, Harindra C
2017-09-01
A subset of patients who require correction of a stenotic or incompetent valve are deemed to be at excessive surgical risk, which precludes surgical repair or replacement. Transcatheter valve interventions are viable alternatives in these patients. However, these technologies are costly, and in the setting of a constrained Canadian health care budget, economic value is an important consideration to allow for fair allocation of scarce resources. Accordingly, we review the economic literature on transcatheter valve interventions, targeting a general audience. Our specific goals are highlighting how best to interpret these studies and discuss the implications of these technologies on the Canadian health care system. Transcatheter aortic valve replacement (TAVR) is a cost-effective alternative for inoperable patients who otherwise would receive medical therapy. When compared with surgical aortic valve replacement (SAVR), TAVR is associated with significant reductions in postprocedure hospital resource use, which offsets the substantially higher cost of the TAVR valve system relative to SAVR valves. Although cost-effectiveness estimates for TAVR in high-risk operable candidates vary widely across studies, based on contemporary data from the perspective of the Canadian health care system, TAVR is likely to provide economic value. Recent studies suggest that when compared with medical therapy for severe degenerative mitral regurgitation, the MitraClip (Abbott, Abbott Park, IL) may offer economic value in high-risk patients; however, in the absence of randomized controlled trials, this is speculative. Nonetheless, these transcatheter technologies represent a paradigm shift in the management of valvular disease; their dissemination will have substantial impact in cardiovascular care delivery. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Kottmaier, Marc; Hettich, Ina; Deutsch, Marcus-André; Badiu, Catalin; Krane, Markus; Lange, Ruediger; Bleiziffer, Sabine
2017-04-01
Background Since biological valve recipients are likely to need a redo procedure in the future for valve deterioration, we hypothesized patients might be more fearful about the progression of their disease than patients after aortic valve replacement (AVR) with a mechanical valve. The aim of this study is to compare the quality of life (QOL) and anxiety in patients who have undergone biological versus mechanical AVR. Method A total of 56 patients after mechanical AVR (mean age: 64.4 ± 8.17 years) and 66 patients after biological AVR (mean age: 64.8 ± 11.05 years) received three questionnaires 5.66 (± 2.68) years after surgery, including: The short form-36 (SF-36) to assess QOL, the fear of progression questionnaire (FOP), and the cardiac anxiety questionnaire (CAQ) to assess general anxiety, anxiety related to cardiac symptoms, and anxiety about progression of heart disease and valve and anticoagulation-specific questions. Results No significant differences were found for all categories of the SF-36. The FOP showed significantly favorable values for the biological AVR group. The CAQ showed a tendency in the subscale "avoidance" (i.e., avoidance of pulse increase) and "attention" towards more favorable values for the biological AVR group. Conclusions In contrast to our hypothesis, patients after mechanical AVR show significantly higher anxiety values for the FOP, and a tendency toward higher values for "avoidance" (i.e., avoidance of pulse increase). Partnership concerns, especially in terms of sexuality can be explained by factors that are recognizable for the partner, such as valve sound. These data provide evidence that factors that are continuously present after mechanical AVR, such as valve sound or anticoagulation might affect wellbeing stronger than the certainty of reoperation in the future after biological AVR. We conclude that implantation of a biological prosthesis can be justified in younger patients with regards to QOL. Georg Thieme Verlag KG Stuttgart · New York.
Computerized system for the follow-up of patients with heart valve replacements.
Bain, W H; Fyfe, I C; Rodger, R A
1985-04-01
A system is described which will accept, store, retrieve and analyze information on large numbers of patients who undergo valve replacement surgery. The purpose of the database is to yield readily available facts concerning the patient's clinical course, prosthetic valve function, length of survival, and incidence of complications. The system uses the Apple Macintosh computer, which is one of the current examples of small, desk-top microprocessors. The software for the input, editing and analysis programs has been written by a professional software writer in close collaboration with a cardiac surgeon. Its content is based on 8 years' experience of computer-based valve follow-up. The system is inexpensive and has proved easy to use in practice.
Fisics-Incor bovine pericardial bioprostheses: 15 year results.
Pomerantzeff, P M; Brandao, C M; Cauduro, P; Puig, L B; Grinberg, M; Tarasoutchi, F; Cardoso, L F; Lerner, A; Stolf, N A; Verginelli, G; Jatene, A D
1998-01-01
From March 1982 to December 1995, 2,607 Fisics-Incor bovine pericardial bioprostheses were implanted in 2,259 patients. Mean age was 47.2 +/- 17.5 years, and 55% were male. Rheumatic fever was present in 1,301 (45.7%) patients. One thousand and seventy-three aortic valve replacements, 1,085 mitral replacements, 27 tricuspid replacements, 195 mitral-aortic replacements, and 16 other combined valve replacements were carried out. Combined procedures were performed in 788 (32.9%) patients, the most frequent being tricuspid valve repair (9.2%) and coronary artery bypass grafting (7.7%). Hospital mortality was 8.6% (194 patients), 8.6% for the mitral group, 4.7% for the aortic group, and 12.8% for double-valve replacements. The linear rates for calcification, thromboembolism, rupture, leak and endocarditis were, respectively, 1.1%, 0.2%, 0.9%, 0.1% and 0.5% patient-year. The actuarial survival curve was 56.7 +/- 5.4% in 15 years. Survival free from endocarditis was 91.92%, survival free from thromboembolism was 95 +/- 1.7%, survival free from rupture was 43.7 +/- 9.8%, survival free from leak was 98.9 +/- 4.5%, and survival free from calcification was 48.8 +/- 7.9% in 15 years. In the late postoperative period, 1,614 (80.6%) patients were in New York Heart Association functional Class I. We conclude that the results with the Fisics-Incor bovine pericardial prostheses were satisfactory in our group of patients.
Dynamic performance of high speed solenoid valve with parallel coils
NASA Astrophysics Data System (ADS)
Kong, Xiaowu; Li, Shizhen
2014-07-01
The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts. The increase of magnetic force usually leads to the decrease of current slew rate, which could increase the delay time of the dynamic response of solenoid valve. Using a high voltage to drive coil can solve this contradiction, but a high driving voltage can also lead to more cost and a decrease of safety and reliability. In this paper, a new scheme of parallel coils is investigated, in which the single coil of solenoid is replaced by parallel coils with same ampere turns. Based on the mathematic model of high speed solenoid valve, the theoretical formula for the delay time of solenoid valve is deduced. Both the theoretical analysis and the dynamic simulation show that the effect of dividing a single coil into N parallel sub-coils is close to that of driving the single coil with N times of the original driving voltage as far as the delay time of solenoid valve is concerned. A specific test bench is designed to measure the dynamic performance of high speed on/off solenoid valve. The experimental results also prove that both the delay time and switching time of the solenoid valves can be decreased greatly by adopting the parallel coil scheme. This research presents a simple and practical method to improve the dynamic performance of high speed on/off solenoid valve.
Elective removal of convexo-concave Björk-Shiley valves.
Rajesh, P B; Smith, G H; Lawford, P V; Black, M M
1994-08-01
Replacement has been an accepted method for treating advanced cardiac valvular disease for more than 25 years. However, the perfect prosthesis has yet to be developed, judging by the number of devices available. A prosthesis that initially appears promising may cause problems in due course, and indeed some devices have been modified or withdrawn from clinical use. A notable example of a prosthetic valve that has give problems is the Björk-Shiley convexo-concave prosthesis, some models of which have undergone mechanical failure due to strut fracture. We report the elective removal of such a valve and the subsequent examination of the prosthesis. The results of this examination suggest that a policy of elective removal is justified.
[Minor strut fracture of the Björk-Shiley mitral valve].
Sugita, T; Yasuda, R; Watarida, S; Onoe, M; Tabata, R; Mori, A
1990-06-01
In May, 1982, a 49-year-old man underwent mitral valve replacement (MVR) in our hospital with a 31 mm Björk-Shiley prosthesis for mitral regurgitation. He had been doing well until his episode of palpitation and dyspnea of sudden onset, and was transferred to our ICU with severe cardiogenic shock in Aug, 1986. Chest X-ray film revealed pulmonary edema and breakage of the valve with migration of the disc and the minor strut of the prosthesis. He was operated upon 5 hours after the onset of his complaints. The minor strut was removed from the left upper pulmonary vein and mitral valve re-replacement was done with a 29 mm Björk-Shiley Monostrut valve. The disc which had dislocated into the abdominal aorta was also recovered on the twenty-third post operative day. His postoperative course was uneventful. Immediate diagnosis and subsequent re-operation is absolute indication for rescue from acute cardiac failure due to mechanical failure of any prosthetic valve.
Fukuta, Yuriko; Yildiz-Aktas, Isil Z; William Pasculle, A; Veldkamp, Peter J
2012-06-01
Legionella endocarditis is extremely uncommon, and embolic phenomena have never been reported. We report the first case of Legionella micdadei prosthetic valve endocarditis complicated by brain abscess. A 57-y-old immunocompromised woman with a history of mitral valve replacement developed confusion and left-sided weakness. Brain magnetic resonance imaging showed a 3-cm peripheral-enhancing mass. Transoesophageal echocardiography suggested a perivalvular abscess. Blood cultures and valve cultures were negative. She was diagnosed with 16S rRNA polymerase chain reaction and silver stain, and was discharged with levofloxacin after a redo mitral valve replacement. Twelve cases of Legionella endocarditis were reviewed. Only one case had a native valve, and her endocarditis occurred after pneumonia. All cases were cured. The duration of antibiotic therapy was variable. Legionella species should be considered in the differential diagnosis of culture-negative endocarditis in both immunocompetent and immunocompromised patients. Molecular techniques and silver impregnation stains are useful, especially when cultures using buffered charcoal-yeast extract agar are negative.
Suleiman, Tariq; Kavinsky, Clifford J.; Skerritt, Clare; Kenny, Damien; Ilbawi, Michael N.; Caputo, Massimo
2015-01-01
An increasing number of patients with tetralogy of Fallot require repeat surgical intervention for pulmonary valve replacement secondary to pulmonary regurgitation. Catheter-based interventions have emerged as an attractive alternative to surgery in this patient population but it is limited by patient size or the anatomy of the right ventricular outflow tract. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. The purpose of this review is to highlight the recent advances in the hybrid field of pulmonary valve replacement, summarizing the advantages and disadvantages of the “traditional” surgical and the new catheter-based techniques and discuss the direction future research should take to determine the optimal management for individual patients. PMID:26082929
Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H
2015-06-09
Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p < 0.001). Thoracic aortic aneurysms were significantly more likely to be diagnosed in late follow-up in patients with Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p < 0.001). Patients with Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p < 0.001). The much higher long-term rates of aortic complications after AVR observed in patients with Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Tam, H.; Zhang, W.; Infante, D.; Parchment, N.; Sacks, M.
2018-01-01
Bioprosthetic heart valves (BHVs), derived from glutaraldehyde crosslinked (GLUT) porcine aortic valve leaflets or bovine pericardium (BP), are used to replace defective heart valves. However, valve failure can occur within 12–15 years due to calcification and/or progressive structural degeneration. We present a novel fabrication method that utilizes carbodiimide, neomycin trisulfate, and pentagalloyl glucose crosslinking chemistry (TRI) to better stabilize the extracellular matrix of BP. We demonstrate that TRI-treated BP is more compliant than GLUT-treated BP. GLUT-treated BP exhibited permanent geometric deformation and complete alteration of apparent mechanical properties when subjected to induced static strain. TRI BP, on the other hand, did not exhibit such permanent geometric deformations or significant alterations of apparent mechanical properties. TRI BP also exhibited better resistance to enzymatic degradation in vitro and calcification in vivo when implanted subcutaneously in juvenile rats for up to 30 days. PMID:28213846
Heart valves from polyester fibers: a preliminary 6-month in vivo study.
Vaesken, Antoine; Pelle, Anne; Pavon-Djavid, Graciela; Rancic, Jeanne; Chakfe, Nabil; Heim, Frederic
2018-06-27
Transcatheter aortic valve implantation (TAVI) has become a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in TAVI procedures for over a decade, with over 150,000 implantations to date. However, with only 6 years of follow up, little is known about the long-term durability of biological tissue. Moreover, the high cost of tissue harvesting and chemical treatment procedures favor the development of alternative synthetic valve leaflet materials. In that context, textile polyester [polyethylene terephthalate (PET)] could be considered as an interesting candidate to replace the biological valve leaflets in TAVI procedures. However, no result is available in the literature about the behavior of textile once in contact with biological tissue in the valve position. The interaction of synthetic textile material with living tissues should be comparable to biological tissue. The purpose of this preliminary work is to compare the in vivo performances of various woven textile PET valves over a 6-month period in order to identify favorable textile construction features. In vivo results indicate that fibrosis as well as calcium deposit can be limited with an appropriate material design.
NASA Astrophysics Data System (ADS)
Hatoum, Hoda; Dasi, Lakshmi Prasad
2017-11-01
Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.
Stähli, Barbara E.; Nguyen-Kim, Thi Dan Linh; Gebhard, Cathérine; Frauenfelder, Thomas; Tanner, Felix C.; Nietlispach, Fabian; Maisano, Francesco; Falk, Volkmar; Lüscher, Thomas F.; Maier, Willibald; Binder, Ronald K.
2015-01-01
Low-flow low-gradient severe aortic stenosis (LFLGAS) is associated with worse outcomes. Aortic valve calcification patterns of LFLGAS as compared to non-LFLGAS have not yet been thoroughly assessed. 137 patients undergoing transcatheter aortic valve replacement (TAVR) with preprocedural multidetector computed tomography (MDCT) and postprocedural transthoracic echocardiography were enrolled. Calcification characteristics were assessed by MDCT both for the total aortic valve and separately for each leaflet. 34 patients had LFLGAS and 103 non-LFLGAS. Total aortic valve calcification volume (p < 0.001), mass (p < 0.001), and density (p = 0.004) were lower in LFLGAS as compared to non-LFLGAS patients. At 30-day follow-up, mean transaortic pressure gradients and more than mild paravalvular regurgitation did not differ between groups. In conclusion, LFLGAS and non-LFLGAS express different calcification patterns which, however, did not impact on device success after TAVR. PMID:26435875
The tricuspid valve and the right heart: anatomical, pathological and imaging specifications.
van Rosendael, Philippe J; Delgado, Victoria; Bax, Jeroen J
2015-09-01
Transcatheter tricuspid valve repair/replacement is an emerging therapy for patients with symptomatic severe tricuspid regurgitation who are deemed inoperable. Accurate knowledge of the anatomy of the tricuspid valve and right ventricle is key to developing transcatheter techniques. In addition, it is important to understand the mechanistic concept of transcatheter tricuspid valve repair/replacement in order to select the patients who may benefit from it. The severity and mechanism of tricuspid regurgitation, right ventricular function, dimensions of the caval veins and the course of the right coronary artery in relation to the atrioventricular groove are important aspects to be evaluated before embarking on these procedures. The present article reviews current advances in transcatheter approaches for significant tricuspid regurgitation and the role of imaging modalities to characterise the anatomy of the tricuspid valve and right ventricle as well as the underlying pathophysiology of tricuspid regurgitation.
Fungal Endocarditis Due to Aspergillus oryzae: The First Case Reported in the Literature.
Mazza, Andrea; Luciani, Nicola; Luciani, Marco; Cammertoni, Federico; Giaquinto, Alessia; Pavone, Natalia; Bruno, Piergiorgio; Massetti, Massimo
2017-03-01
Infective endocarditis (IE) is a severe disease with high mortality and morbidity. Prosthetic valve endocarditis is a life-threatening complication which can occur in less than 10% of patients with valve prosthesis. A fungal etiology of IE is rare and accounts for only 2-4% of all case of endocarditis, but is associated with a higher mortality and morbidity. Herein is reported the first case of fungal endocarditis of aortic valve prosthesis due to Aspergillus oryzae in a 67-year-old caucasian man who nine years previously underwent mitral and aortic valve replacement with mechanical prostheses, and tricuspid annuloplasty for acute IE due to Enterococcus spp. Seven months previously, the patient also underwent a redo cardiac procedure to replace a mitral valve prosthesis with a new mechanical device due to a leakage. Aspergillus oryzae showed impressive growth with strong and unexpected virulence in both local and systemic settings.
Pros and cons of transcatheter aortic valve implantation (TAVI)
Terré, Juan A.; George, Isaac
2017-01-01
Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement. PMID:29062739
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-01-01
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable. PMID:24510692
A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.
Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh
2014-02-07
A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.
Atrioventricular and intraventricular block after transcatheter aortic valve implantation.
Lee, Jane J; Goldschlager, Nora; Mahadevan, Vaikom S
2018-06-24
Aortic stenosis is the most common valvular heart disease in industrialized countries and the most common cause of left ventricular outflow tract (LVOT) obstruction. Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement for intermediate to high-risk surgical candidates with symptomatic severe aortic stenosis. Conduction system abnormalities, including atrioventricular (AV) and intraventricular (IV) block, are the most common complication of TAVR. In this review, we aim to explore the anatomical issues relevant to atrioventricular block, the relevant clinical and procedural aspects, and the management and long-term implications of AV and IV block.
Pivatto Júnior, Fernando; Teixeira Filho, Guaracy Fernandes; Sant'anna, João Ricardo Michelin; Py, Pablo Mondim; Prates, Paulo Roberto; Nesralla, Ivo Abrahão; Kalil, Renato Abdala Karam
2014-01-01
Objective This study aims to describe the correlation between age and occurrence of atrial fibrillation after aortic stenosis surgery in the elderly as well as evaluate the influence of atrial fibrillation on the incidence of strokes, hospital length of stay, and hospital mortality. Methods Cross-sectional retrospective study of > 70 year-old patients who underwent isolated aortic valve replacement. Results 348 patients were included in the study (mean age 76.8±4.6 years). Overall, post-operative atrial fibrillation was 32.8% (n=114), but it was higher in patients aged 80 years and older (42.9% versus 28.8% in patients aged 70-79 years, P=0.017). There was borderline significance for linear correlation between age and atrial fibrillation (P=0.055). Intensive Care Unit and hospital lengths of stay were significantly increased in atrial fibrillation (P<0.001), but there was no increase in mortality or stroke associated with atrial fibrillation. Conclusion Post-operative atrial fibrillation incidence in aortic valve replacement is high and correlates with age in patients aged 70 years and older and significantly more pronounced in patients aged 80 years. There was increased length of stay at Intensive Care Unit and hospital, but there was no increase in mortality or stroke. These data are important for planning prophylaxis and early treatment for this subgroup. PMID:24896162
Zhao, Li; Chen, Chunxia; Li, Bei; Dong, Li; Guo, Yingqiang; Xiao, Xijun; Zhang, Eryong; Qin, Li
2014-01-01
Objective To study the performance of pharmacogenetics-based warfarin dosing algorithms in the initial and the stable warfarin treatment phases in a cohort of Han-Chinese patients undertaking mechanic heart valve replacement. Methods We searched PubMed, Chinese National Knowledge Infrastructure and Wanfang databases for selecting pharmacogenetics-based warfarin dosing models. Patients with mechanic heart valve replacement were consecutively recruited between March 2012 and July 2012. The predicted warfarin dose of each patient was calculated and compared with the observed initial and stable warfarin doses. The percentage of patients whose predicted dose fell within 20% of their actual therapeutic dose (percentage within 20%), and the mean absolute error (MAE) were utilized to evaluate the predictive accuracy of all the selected algorithms. Results A total of 8 algorithms including Du, Huang, Miao, Wei, Zhang, Lou, Gage, and International Warfarin Pharmacogenetics Consortium (IWPC) model, were tested in 181 patients. The MAE of the Gage, IWPC and 6 Han-Chinese pharmacogenetics-based warfarin dosing algorithms was less than 0.6 mg/day in accuracy and the percentage within 20% exceeded 45% in all of the selected models in both the initial and the stable treatment stages. When patients were stratified according to the warfarin dose range, all of the equations demonstrated better performance in the ideal-dose range (1.88–4.38 mg/day) than the low-dose range (<1.88 mg/day). Among the 8 algorithms compared, the algorithms of Wei, Huang, and Miao showed a lower MAE and higher percentage within 20% in both the initial and the stable warfarin dose prediction and in the low-dose and the ideal-dose ranges. Conclusions All of the selected pharmacogenetics-based warfarin dosing regimens performed similarly in our cohort. However, the algorithms of Wei, Huang, and Miao showed a better potential for warfarin prediction in the initial and the stable treatment phases in Han-Chinese patients undertaking mechanic heart valve replacement. PMID:24728385
New valve and bonding designs for microfluidic biochips containing proteins.
Lu, Chunmeng; Xie, Yubing; Yang, Yong; Cheng, Mark M-C; Koh, Chee-Guan; Bai, Yunling; Lee, L James; Juang, Yi-Je
2007-02-01
Two major concerns in the design and fabrication of microfluidic biochips are protein binding on the channel surface and protein denaturing during device assembly. In this paper, we describe new methods to solve these problems. A "fishbone" microvalve design based on the concept of superhydrophobicity was developed to replace the capillary valve in applications where the chip surface requires protein blocking to prevent nonspecific binding. Our experimental results show that the valve functions well in a CD-like ELISA device. The packaging of biochips containing pre-loaded proteins is also a challenging task since conventional sealing methods often require the use of high temperatures, electric voltages, or organic solvents that are detrimental to the protein activity. Using CO2 gas to enhance the diffusion of polymer molecules near the device surface can result in good bonding at low temperatures and low pressure. This bonding method has little influence on the activity of the pre-loaded proteins after bonding.
Mortality characteristics of aortic root surgery in North America†
Caceres, Manuel; Ma, Yicheng; Rankin, J. Scott; Saha-Chaudhuri, Paramita; Englum, Brian R.; Gammie, James S.; Suri, Rakesh M.; Thourani, Vinod H.; Esmailian, Fardad; Czer, Lawrence S.; Puskas, John D.; Svensson, Lars G.
2014-01-01
OBJECTIVES Aortic root surgery is transitioning to aortic valve sparing (AVS), but little is known about the relative early outcomes of AVS versus composite graft-valve replacement (CVR). This study assessed mortality differences for AVS versus CVR to guide future practice decisions. METHODS From January 2000 to June 2011, 31 747 patients had aortic root replacement with AVS (n = 3585; 11%) or CVR (n = 28 162; 89%). The cohort of Overall patients was divided into two subgroups: high-risk patients (n = 20 356; 6% AVS) having age >75 years, endocarditis, aortic stenosis, dialysis, multiple valves, reoperation or emergency/salvage status, and the remaining low-risk patients (n = 11 388; 21% AVS). Using logistic regression analysis, outcomes were presented as unadjusted operative mortality (UOM), risk-adjusted operative mortality (AOM) and adjusted odds ratio (AOR) for mortality. RESULTS Baseline characteristics for the Overall group (AVS versus CVR) were: mean age (52 vs 57 years), endocarditis (1 vs 11%), aortic stenosis (4 vs 36%), dialysis (1 vs 2%), multiple valves (7 vs 10%), reoperation (6 vs 17%) and emergency status (14 vs 12%) (all P < 0.0001). In high- and low-risk groups, baseline differences narrowed, and lower mortality was generally observed with AVS: (AVS versus CVR) UOM group Overall (4.5 vs 8.9%)*, group High-risk (10.5 vs 11.7%), group Low-risk (1.4 vs 3.1%)*; AOM group Overall (6.2 vs 8.6%), group High-risk (10.1 vs 11.7%), group Low-risk (2.2 vs 2.8%); AOR group Overall (0.59)*, group High-risk (0.62)*, group Low-risk (0.69). *P < 0.05. CONCLUSIONS Relative risk-adjusted mortality seemed comparable with AVS versus CVR in low- and high-risk subgroups. These data support judicious expansion of aortic valve repair in patients having aortic root replacement. PMID:24639452
Rupprath, G; Vogt, J; de Vivie, E R; Beuren, A J
1981-12-01
The results are presented of 44 systematic cardiac catheterizations in 35 patients after successful repair of various types of congenital cyanotic heart disease using a conduit. The operations were performed from 1972 to 1981. The patients were followed from 6 months to 9 years, the mean interval between operation and catheterization was 2.5 years (4 weeks to 8 years). Different types of conduits were used: a Hancock conduit in 27 cases (1 replaced), an aortic homograft in 3 cases (all 3 replaced by a Hancock conduit), a Dacron tube with Lillehei-Kaster valve in 2 cases (1 replaced), a lonescu-Shiley conduit in 5 cases, a composite graft of pericardium and a Hancock valve in one patient (replaced) and a valveless Dacron tube in one patient. The total conduit gradient was differentiated in 43/44 investigations. For the Hancock conduit the mean proximal gradient was 9 mmHg, the valvular 14 and the distal 13 mmHg. Severe valvular stenosis of the porcine valve occurred in 3 patients. For the lonescu-Shiley conduit only early, but promising, results are available. Three of the 35 patients died late (2.5 and 4 years postoperatively); the deaths were related to severe additional lesions. Cross-sectional echocardiography was performed in 32 of the 35 patients. The latter does not appear to be a reliable method for the detection of valvular lesions so far, but is helpful for the diagnosis of proximal and distal obstructions of the conduit.
[Indications for and clinical outcome of the Ross procedure: a review].
Morita, K; Kurosawa, H
2001-04-01
The Ross procedure has been used increasingly to treat aortic valve disease in children and young adults. The primary indication for the Ross procedure is to provide a permanent valve replacement in children with congenital aortic stenosis. More recently, it has been extended to young adults with a bicuspid aortic valve and small aortic annulus, especially women wishing to have children. Other possible indications include complex left ventricular outflow obstructive disease, native or prosthetic valve endocarditis, and adult aortic insufficiency with a dilated aortic annulus. Conversely, Marfan syndrome is considered to an absolute contraindication, and this procedure should be used with caution in patients with rheumatic valve disease and a dysplastic dilated aortic root because of the higher associated incidence of autograft dysfunction. The technique of total aortic root replacement has become the preferred method of autograft implantation, because it carries the lowest risk of pulmonary autograft failure. In patients with marked graft-host size mismatch, either concomitant aortic annulus reduction and fixation or aortic annulus enlargement (i.e., the Ross-Konno procedure) should be performed. The Ross Procedure International Registry data document that in the modern era (post-1986) the early and late mortality rate is 2.5% and 1%, respectively. Excellent long-term results have been reported, and the benefits of this procedure include optimal hemodynamics, low risk of endocarditis, resistance to infection in patients with active endocarditis, and nonthrombogeneicity and therefore few anticoagulation-related complications. The Ross procedure can be performed with acceptable early and mid-term mortality and excellent autograft durability. Further long-term follow-up will confirm the role of this procedure in patients with various types of aortic valve disease.
Troise, Giovanni; Cirillo, Marco; Brunelli, Federico; Tasca, Giordano; Amaducci, Andrea; Mhagna, Zen; Tomba, Margherita Dalla; Quaini, Eugenio
2004-06-01
The results of current surgical options for the treatment of permanent atrial fibrillation (AF) associated with mitral surgery are widely different, particularly in very enlarged left atria. The aim of this study was to assess the mid-term efficacy of cardiac autotransplantation for this goal, through a consistent reduction of left atrium volume and a complete isolation of the pulmonary veins. From April 2000 to September 2002, 30 patients (male/female 5/25) underwent cardiac autotransplantation for the treatment of mitral valve disease and concomitant permanent AF (>1 year). Surgical technique of bicaval heart transplantation was modified maintaining the connection of inferior vena cava in all but three cases. Twenty-eight patients had mitral valve replacement and two had mitral valve repair. Associated procedures were: aortic valve replacement (6 cases), tricuspid valve repair (2 cases), coronary re-vascularization (2 cases) and right atrium volume reduction (4 cases). No hospital death occurred; 1 patient died 3 months post-operatively for pneumonia. At a mean follow-up of 21.1+/-7.7 months (range 6-35), 26 patients (89.7%) were in sinus rhythm and 3 (10.3%) in AF. Santa Cruz Score was 0 in 3 patients, 2 in 2 patients and 4 in the remaining 24 patients (82.7%). Mean left atrial diameter and volume decreased from 65.1+/-16.4 mm (range 50-130 mm) to 49.9+/-8.4 mm (range 37-78) (P < 0.001) and from 118.3+/-68.4 ml (range 60-426) to 69.4+/-34.1 ml (range 31-226) (P = 0.001), respectively, after the operation. Cardiac autotransplantation is a safe and effective option for the treatment of permanent AF in patients with mitral valve disease and severe dilation of left atrium.
Duan, B; Kapetanovic, E; Hockaday, L A; Butcher, J T
2014-05-01
Tissue engineering has great potential to provide a functional de novo living valve replacement, capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, three-dimensional (3-D) bioprinting enables deposition of cells and hydrogels into 3-D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach, however, is constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not known how human valve cells respond to these printed environments. In this study, 3-D printable formulations of hybrid hydrogels are developed, based on methacrylated hyaluronic acid (Me-HA) and methacrylated gelatin (Me-Gel), and used to bioprint heart valve conduits containing encapsulated human aortic valvular interstitial cells (HAVIC). Increasing Me-Gel concentration resulted in lower stiffness and higher viscosity, facilitated cell spreading, and better maintained HAVIC fibroblastic phenotype. Bioprinting accuracy was dependent upon the relative concentrations of Me-Gel and Me-HA, but when optimized enabled the fabrication of a trileaflet valve shape accurate to the original design. HAVIC encapsulated within bioprinted heart valves maintained high viability, and remodeled the initial matrix by depositing collagen and glyosaminoglycans. These findings represent the first rational design of bioprinted trileaflet valve hydrogels that regulate encapsulated human VIC behavior. The use of anatomically accurate living valve scaffolds through bioprinting may accelerate understanding of physiological valve cell interactions and progress towards de novo living valve replacements. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Tice, Jeffrey A; Sellke, Frank W; Schaff, Hartzell V
2014-08-01
The California Technology Assessment Forum is dedicated to assessment and public reporting of syntheses of available data on medical technologies. In this assessment, transcatheter aortic valve replacement (TAVR) was evaluated for patients with severe aortic stenosis (AS) who are at high risk for complications. In this assessment, 5 criteria were used: Regulatory approval, sufficient scientific evidence to allow conclusions on effectiveness, evidence that the technology improves net health outcomes, evidence that the technology is as beneficial as established methods, and availability of the technology outside investigational settings. In this assessment, all 5 criteria were judged to have been met. The primary benefit of TAVR is the ability to treat AS in patients who would otherwise be ineligible for surgical aortic valve replacement. It may also be useful for patients at high surgical risk by potentially reducing periprocedural complications and avoiding the morbidity and recovery from undergoing heart surgery. Potential harms include the need for conversion to an open procedure, perioperative death, myocardial infarction, stroke, bleeding, valve embolization, aortic regurgitation, heart block that requires a permanent pacemaker, renal failure, pulmonary failure, and major vascular complications such as cardiac perforation or arterial dissection. Potential long-term harms include death, stroke, valve failure or clotting, and endocarditis. As highlighted at the February 2012 California Technology Assessment Forum meeting, the dispersion of this technology to new centers across the United States must proceed with careful thought given to training and proctoring multidisciplinary teams to become new centers of excellence. TAVR is a potentially lifesaving procedure that may improve quality of life for patients at high risk for surgical AVR. However, attention needs to be paid to appropriate patient selection, their preoperative evaluation, surgical techniques, and postoperative care to preserve and improve on the results attained in the Placement of Aortic Transcatheter Valve trial. Specialty societies are collaborating to ensure that this happens in a rational and comprehensive manner. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J
2016-01-05
Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement [Medtronic CoreValve U.S. Pivotal Trial]; NCT01240902). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Erek, Ersin; Casselman, Filip P.A.; Vanermen, Hugo
2004-01-01
We report the case of 67-year-old woman who underwent aortic valve replacement and mitral valve repair due to ochronotic valvular disease (alkaptonuria), which was diagnosed incidentally during cardiac surgery. PMID:15745303
Durability of Aortic Valve Cusp Repair With and Without Annular Support.
Zeeshan, Ahmad; Idrees, Jay J; Johnston, Douglas R; Rajeswaran, Jeevanantham; Roselli, Eric E; Soltesz, Edward G; Gillinov, A Marc; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Pettersson, Gösta B; Blackstone, Eugene H; Sabik, Joseph F; Svensson, Lars G
2018-03-01
To determine the value of aortic valve repair rather than replacement for valve dysfunction, we assessed late outcomes of various repair techniques in the contemporary era. From January 2001 to January 2011, aortic valve repair was planned in 1,124 patients. Techniques involved commissural figure-of-8 suspension sutures (n = 63 [6.2%]), cusp repair with commissuroplasty (n = 481 [48%]), debridement (n = 174 [17%]), free-margin plication (n = 271 [27%]) or resection (n = 75) or both, or annulus repair with resuspension (n = 230 [23%]), root reimplantation (n = 252 [25%]), or remodeling (n = 35 [3.5%]). Planned repair was aborted for replacement in 115 patients (10%); risk factors included greater severity of aortic regurgitation (AR; p = 0.0002) and valve calcification (p < 0.0001). In-hospital outcomes for the remaining 1,009 patients included death (12 [1.2%]), stroke (13 [1.3%]), and reoperation for valve dysfunction (14 [1.4%]). Freedom from aortic valve reoperation at 1, 5, and 10 years was 97%, 93%, and 90%, respectively. Figure-of-8 suspension sutures, valve resuspension, and root repair and replacement were least likely to require reoperation; cusp repair with commissural sutures, plication, and commissuroplasty was most likely (p < 0.05). Survival at 1, 5, and 10 years was 96%, 92%, and 83%. Immediate postoperative AR grade was none-mild (94%), moderate (5%), and severe (1%). At 10 years after repair, AR grade was none (20%), mild (33%), moderate (26%), and severe (21%). Patients undergoing root procedures were less likely to have higher-grade postoperative AR (p < 0.0001). Valve repair is effective and durable for treating aortic valve dysfunction. Greater severity of AR preoperatively is associated with higher likelihood of repair failure. Commissural figure-of-8 suspension sutures and repair with annular support have the best long-term durability. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Semaan, Edouard; Markl, Michael; Chris Malaisrie, S.; Barker, Alex; Allen, Bradley; McCarthy, Patrick; Carr, James C.; Collins, Jeremy D.
2014-01-01
OBJECTIVE To provide a more complete characterization of aortic blood flow in patients following valve-sparing aortic root replacement (VSARR) compared with presurgical cohorts matched by tricuspid and bicuspid valve morphology, age and presurgical aorta size. METHODS Four-dimensional (4D) flow magnetic resonance imaging (MRI) was performed to analyse three-dimensional (3D) blood flow in the thoracic aorta of n = 13 patients after VSARR with reimplantation of native tricuspid aortic valve (TAV, n = 6) and bicuspid aortic valve (BAV, n = 7). Results were compared with presurgical age and aortic size-matched control cohorts with TAV (n = 10) and BAV (n = 10). Pre- and post-surgical aortic flow was evaluated using time-resolved 3D pathlines using a blinded grading system (0–2, 0 = small, 1 = moderate and 2 = prominent) analysing ascending aortic (AAo) helical flow. Systolic flow profile uniformity in the aortic root, proximal and mid-AAo was evaluated using a four-quadrant model. Further analysis in nine analysis planes distributed along the thoracic aorta quantified peak systolic velocity, retrograde fraction and peak systolic flow acceleration. RESULTS Pronounced AAo helical flow in presurgical control subjects (both BAV and TAV: helix grading = 1.8 ± 0.4) was significantly reduced (0.2 ± 0.4, P < 0.001) in cohorts after VSARR independent of aortic valve morphology. Presurgical AAo flow was highly eccentric for BAV patients but more uniform for TAV. VSARR resulted in less eccentric flow profiles. Systolic peak velocities were significantly (P < 0.05) increased in post-root repair BAV patients throughout the aorta (six of nine analysis planes) and to a lesser extent in TAV patients (three of nine analysis planes). BAV reimplantation resulted in significantly increased peak velocities in the proximal AAo compared with root repair with TAV (2.3 ± 0.6 vs 1.6 ± 0.4 m/s, P = 0.017). Post-surgical patients showed a non-significant trend towards higher systolic flow acceleration as a surrogate measure of reduced aortic compliance. CONCLUSIONS VSARR restored a cohesive flow pattern independent of native valve morphology but resulted in increased peak velocities throughout the aorta. 4D flow MRI methods can assess the clinical implications of altered aortic flow dynamics in patients undergoing VSARR. PMID:24317086
Kon, Neal D; Riley, Robert D; Adair, Sandy M; Kitzman, Dalane W; Cordell, A Robert
2002-06-01
Stentless porcine aortic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation, and perhaps improved durability. One hundred four patients were operated on from September 17, 1992, to October 31, 1997, as part of a multicenter worldwide investigation of the Medtronic Freestyle stentless porcine bioprosthesis. All patients received a total aortic root replacement. The patients were evaluated postoperatively at discharge, at 3 to 6 months, and yearly by clinical examination and color flow Doppler echocardiography. Operative mortality was 3.9%. No patient experienced structural valve deterioration, nonstructural deterioration, perivalvular leak, or unacceptable hemodynamic performance. At 8 years, survival was 59.8%. Freedom from thromboembolic complications was 83.3%. Freedom from postoperative endocarditis was 96.9%. Freedom from reoperation was 100%. Mean systolic gradients did not change over the time period studied. They were 6.4 +/- 3.8 mm Hg at 1 year and 6.7 +/- 2.6 mm Hg at 8 years. Correspondingly, effective orifice area was 1.9 +/- 0.7 cm2 at 1 year and 1.8 +/- 0.8 cm2 at 8 years. The incidence of any aortic insufficiency also did not change over the length of follow-up. At 1 year, 98% of patients had no or trivial aortic insufficiency and 2% had mild aortic insufficiency. At 8 years, 100% of patients evaluated were free of any aortic insufficiency. The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root or aortic valve for aortic valve and aortic root pathology. Total root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Results up to 8 years show excellent survival and no signs of degeneration. Further follow-up is still needed to determine valve durability.
Horne, Aaron; Reineck, Elizabeth A; Hasan, Rani K; Resar, Jon R; Chacko, Matthews
2014-10-01
Severe aortic stenosis (AS) results in considerable morbidity and mortality without aortic valve replacement and is expected to increase in prevalence with the aging population. Because AS primarily affects the elderly, many patients with comorbidities are poor candidates for surgical aortic valve replacement (SAVR) and may not be referred. Transcatheter aortic valve replacement (TAVR) has emerged as transformative technology for the management of AS over the past decade. Randomized trials have established the safety and efficacy of TAVR with improved mortality and quality of life compared with medical therapy in inoperable patients, while demonstrating noninferiority and even superiority to SAVR among high-risk operative candidates. However, early studies demonstrated an early penalty of stroke and vascular complications with TAVR as well as increased paravalvular leak as compared with SAVR. Two device platforms have been evaluated and approved for use in the United States: the Edwards SAPIEN and the Medtronic CoreValve. Early studies also suggest cost-effectiveness for TAVR. Ongoing studies are evaluating new iterations of the aforementioned TAVR devices, novel device designs, and applications of TAVR in expanded populations of patients including those with lower risk profiles as well as those with comorbidities that were excluded from early clinical trials. Future improvements in TAVR technology will likely reduce periprocedural and long-term complications. Further studies are needed to confirm device durability over long-term follow-up and explore the applicability of TAVR to broader AS patient populations. Copyright © 2014 Mosby, Inc. All rights reserved.
Aceves-Velázquez, Eduardo; Vieyra-Herrera, Gerardo; Rodríguez-Chávez, Laura; Herrera-Alarcón, Valentín
2017-07-16
According to current guidelines, in patients without additional risk factors who have undergone aortic valve replacement with a bioprosthesis, anticoagulation in the first 3 months after surgery is still a matter of debate. According to current evidence, aspirin in low doses is a reasonable alternative to vitamin K antagonists (VKA). A comparison is made between the incidence of thrombotic and haemorrhagic complications in patients with low thrombotic risk who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico. The hypothesis: aspirin as monotherapy has a beneficial effect compared to VKA. The studied patients were the low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico from 2011 to 2015. The groups studied were: aspirin only, VKA only, and the combination of VKA plus aspirin. The patients were retrospectively followed-up for 12 months, and the thrombotic and haemorrhagic complications were documented. Of the 231 patients included in the study, only one patient in the VKA only group presented with a haemorrhagic complication. No thrombotic complications were observed. In the present study no thrombotic complications were observed in patients who did not receive anticoagulation in the first 3 months after an aortic valve replacement with a bioprosthesis after a follow up period of 12 months. This suggests that the use of aspirin only is safe during this period. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Lauck, Sandra B; Wood, David A; Baumbusch, Jennifer; Kwon, Jae-Yung; Stub, Dion; Achtem, Leslie; Blanke, Philipp; Boone, Robert H; Cheung, Anson; Dvir, Danny; Gibson, Jennifer A; Lee, Bobby; Leipsic, Jonathan; Moss, Robert; Perlman, Gidon; Polderman, Jopie; Ramanathan, Krishnan; Ye, Jian; Webb, John G
2016-05-01
We describe the development, implementation, and evaluation of a standardized clinical pathway to facilitate safe discharge home at the earliest time after transfemoral transcatheter aortic valve replacement. Between May 2012 and October 2014, the Heart Team developed a clinical pathway suited to the unique requirements of transfemoral transcatheter aortic valve replacement in contemporary practice. The components included risk-stratified minimalist periprocedure approach, standardized postprocedure care with early mobilization and reconditioning, and criteria-driven discharge home. Our aim was to reduce variation in care, identify a subgroup of patients suitable for early discharge (≤48 hours), and decrease length of stay for all patients. We addressed barriers related to historical practices, complex multidisciplinary stakeholder engagement, and adoption of length of stay as a quality indicator. We retrospectively reviewed the experiences of 393 consecutive patients; 150 (38.2%) were discharged early. At baseline, early discharge patients had experienced less previous balloon aortic valvuloplasty, had higher left ventricular ejection fraction, better cognitive function, and were less frail than the standard discharge group (>48 hours). Early discharge was associated with the use of local anesthesia, implantation of balloon expandable device, avoidance of urinary catheter, and early removal of temporary pacemaker. Median length of stay was 1 day for early discharge and 3 days for other patients; 97.7% were discharged home. There were no differences in 30-day mortality (1.3%), disabling stroke (0.8%), or readmission (10.7%). The implementation of a transcatheter aortic valve replacement clinical pathway shifted the program's approach to combine standardized processes and individual risk stratification. The Vancouver transcatheter aortic valve replacement clinical pathway requires a rigorous assessment to determine its efficacy, safety, and reproducibility. © 2016 American Heart Association, Inc.
[Modern aortic surgery in Marfan syndrome--2011].
Kallenbach, K; Schwill, S; Karck, M
2011-09-01
Marfan syndrome is a hereditary disease with a prevalence of 2-3 in 10,000 births, leading to a fibrillin connective tissue disorder with manifestations in the skeleton, eye, skin, dura mater and in particular the cardiovascular system. Since other syndromes demonstrate similar vascular manifestations, but therapy may differ significantly, diagnosis should be established using the revised Ghent nosology in combination with genotypic analysis in specialized Marfan centres. The formation of aortic root aneurysms with the subsequent risk of acute aortic dissection type A (AADA) or aortic rupture limits life expectancy in patients with Marfan syndrome. Therefore, prophylactic replacement of the aortic root needs to be performed before the catastrophic event of AADA can occur. The goal of surgery is the complete resection of pathological aortic tissue. This can be achieved with excellent results by using a (mechanically) valved conduit that replaces both the aortic valve and the aortic root (Bentall operation). However, the need for lifelong anticoagulation with Coumadin can be avoided using the aortic valve sparing reimplantation technique according to David. The long-term durability of the reconstructed valve is favourable, and further technical improvements may improve longevity. Although results of prospective randomised long-term studies comparing surgical techniques are lacking, the David operation has become the surgical method of choice for aortic root aneurysms, not only at the Heidelberg Marfan Centre. Replacement of the aneurysmal dilated aortic arch is performed under moderate hypothermic circulatory arrest combined with antegrade cerebral perfusion using a heart-lung machine, which we also use in thoracic or thoracoabdominal aneurysms. Close post-operative follow-up in a Marfan centre is pivotal for the early detection of pathological changes on the diseased aorta.
Del Giglio, Mauro; Mikus, Elisa; Micari, Antonio; Calvi, Simone; Tripodi, Alberto; Campo, Gianluca; Maietti, Elisa; Castriota, Fausto; Cremonesi, Alberto
2018-01-01
Background Right anterior mini-thoracotomy (MIAVR) is a promising technique for aortic valve replacement. We aimed at comparing its outcomes with those obtained in a propensity-matched group of patients undergoing sternotomy at our two high-volume centers. Methods Main clinical and operative data of patients undergoing aortic valve replacement between January 2010 and May 2016 were retrospectively collected. A total of 678 patients were treated with a standard full sternotomy approach, while MIAVR was performed in 502. Propensity score matching identified 363 patients per each group. Results In-hospital mortality was not significantly different between the propensity-matched groups (1.7% in MIAVR patients vs. 2.2% in conventional sternotomy patients; P=0.79). No significant difference in the incidence of major post-operative complications was observed. Post-operative ventilation times (median 7, range 5–12 hours in MIAVR patients vs. median 7, range 5–12 in conventional sternotomy patients; P=0.72) were not significantly different between the two groups. Cardiopulmonary bypass time (61.0±21.0 vs. 65.9±24.7 min in conventional sternotomy group; P<0.01) and aortic cross-clamping time (48.3±16.7 vs. 53.2±19.6 min in full sternotomy group; P<0.01) were shorter in MIAVR group. EuroSCORE (OR 1.52, 95% CI, 1.12–2.06; P<0.01) was found to be the only independent predictor of intra-hospital mortality in the whole propensity-matched population. Conclusions Our experience shows that mini-access isolated aortic valve surgery is a reproducible, safe and effective procedure with similar outcomes and no longer operative times compared to conventional sternotomy. PMID:29707310
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-21
... pressurise the hydraulic reservoirs, due to leakage of the Crissair reservoir air pressurisation check valves. * * * The leakage of the check valves was caused by an incorrect spring material. The affected Crissair check valves * * * were then replaced with improved check valves P/N [part number] 2S2794-1 * * *. More...
Field Experience with Lock Culvert Valves
2013-12-01
factors pertaining to valves such as the hoist loads, cavitation parameter, and effects of venting. To reduce the surge in the navigation channel...2 min 15 sec, filling-and-emptying valve opening time) ensures that adequate air is drawn into the culvert to cushion the cavitation implosions...shape can have adverse hydrodynamic loading consequences. The USACE, Mobile District (SAM) is in the process of designing replacement valves that are
Uhrin, Gábor Balázs; Jensen, Rasmus Hare; Korup, Eva; Grønlund, Jens; Hjort, Ulla; Moser, Claus; Arendrup, Maiken Cavling; Schønheyder, Henrik Carl
2015-01-01
We report Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus) causing recurrent prosthetic valve endocarditis. The fungus was the sole agent detected during replacement of a mechanical aortic valve conduit due to abscess formation. Despite extensive surgery and anti-fungal treatment, the patient had a cerebral hemorrhage 4 months post-surgery prompting a diagnosis of recurrent prosthetic valve endocarditis and fungemia. PMID:26909244
Allen, Bradley S; El-Zein, Chawki; Cuneo, Betina; Cava, Joseph P; Barth, Mary Jane; Ilbawi, Michel N
2002-09-01
There is still no perfect conduit for reconstruction of the right ventricular outflow tract (RVOT) in children. Homografts are not always available in the appropriate size, and degenerate in a few years. This study evaluates the pericardial valve with Gore-Tex conduit as an alternative for RVOT construction. From January 1, 1993, to September 30, 1999, a pericardial tissue valve was inserted in all patients undergoing RVOT reconstruction or pulmonary valve replacement (PVR) who were large enough to accommodate a tissue valve. In patients without a native main pulmonary artery, a new technique was used to construct an RV-PA conduit out of a flat sheet of Gore-Tex, as Dacron frequently leads to stenosis. Data were collected by retrospective review, follow-up echocardiograms, and assessment by a single cardiologist. There were 48 patients, 22 undergoing a PVR alone and 26 a RV-PA valved Gore-Tex conduit. Diagnosis included tetralogy of Fallot (n = 25); truncus arteriosis (n = 9); ventricular septal defect with PA (n = 5); DORV (n = 4); D-TGA with PS (n = 2); and 1 each IAA with sub AS, VSD with PI, and PS s/p Ross procedure. Patient age ranged from 3 to 33 years and 98% were reoperations. The valve sizes ranged from 19 to 33 mm and the median hospital length of stay was 4 days. There were 2 (4.2%) perioperative and 1 (2.1%) late deaths, none related to the valve or Gore-Tex conduit. At a follow-up of 15 to 86 months (mean 43 +/- 16 months), all remaining 45 patients are New York Heart Association class I, all valves are functional, and no patient has required valve or conduit replacement or revision; more importantly, echocardiogram revealed no significant valve or conduit stenosis (mean gradient 16 +/- 8 mm Hg) and no evidence of regurgitation or structural degeneration. A pericardial tissue valve and Gore-Tex conduit provides a reliable alternative for RVOT reconstruction in pediatric patients. It is readily available, molds in the limited retrosternal space, and has outstanding intermediate results with no evidence of failure or deterioration up to 7 years after insertion.
Guteta, Senbeta; Yadeta, Dejuma; Azazh, Aklilu; Mekonnen, Dufera
2016-04-01
Valvular heart disease has been a significant cause of heart disease worldwide. In Ethiopia, it particularly affects young individuals and constitutes the major cause of cardiovascular disease. Factors associated with choice of treatment for advanced valvular heart disease are variable. The objective of this study is to review surgery done for Ethiopian patients with valvular heart disease. We analyzed data on patients who had valve surgery and follow-up at the Tikur Anbessa Specialized Hospital cardiology unit. We collected data on sociodemographic characteristics, the pre-operative status of effected valves and co-morbidities, and assessed their associations with patient management options. A total of 157 valve surgeries were done from 1983 to 2013. Mean age at time of surgery was 26.7 years and females constituted 66% of the cases. Patients with rheumatic heart disease were younger, more likely to be female and have atrial fibrillation, but less likely to have impaired left ventricular systolic function when compared to patients with non-rheumatic heart disease. More than 75% of the surgical procedures done were mechanical valve replacement. Mechanical valves, compared with bioprosthetic valves, were more likely to be used in patients with rheumatic heart disease. The median age of those receiving mechanical valves, 24 (IQR 22-28) years, was lower than those receiving bioprosthetic valves, 31.5 (IQR 29.9-37.9) years. Mechanical valve replacement was significantly higher in those under the age of 20 years (Adjusted Odds Ratio 41.0, 95% CI: 3.0-557.2) and in those between 20 and 29 years of age (Adjusted Odds Ratio 14.3, 95% CI: 2.3-88.6). Valve surgery for valvular heart diseases has been more common performed for young and female patients. A great majority of the replacements done have been with mechanical valves. As many of the patients have been younger and female, the choice of valve surgery and the need for anticoagulation impacts subsequent management of rheumatic heart disease and associated morbidities, lifestyle plans and pregnancy.
Aslan, Abdullah Nabi; Kasapkara, Hacı Ahmet; Sivri, Serkan; Güney, Murat Can; Bozkurt, Engin
2017-01-01
Transcatheter aortic valve replacement (TAVR) was designed to treat elderly patients with severe aortic stenosis at high risk for surgery, and is most commonly performed with retrograde approach through femoral arteries. However, in up to 30% of cases, it is either not possible to use this access route or it is considered to have high risk of vascular injury. Alternative approaches have been described for patients with no suitable femoral access: trans-subclavian, transaortic, or direct aortic access; however, since the introduction of new valves deployed with low-profile delivery systems, another alternative transcatheter approach has been discovered. Presently described is experience in 2 cases in which patients were treated with transfemoral TAVR using Edwards SAPIEN 3 transcatheter heart valves immediately following ipsilateral common iliac artery stenting.
An unusual cause of hemolysis in a patient with an aortic valved conduit replacement.
Allman, Christine; Rajaratnam, Rohan; Kachwalla, Hashim; Hughes, Clifford F; Bannon, Paul; Leung, Dominic Y
2003-02-01
Hemolytic anemia is a well-known but uncommon complication in patients with prosthetic heart valves. It is most commonly a result of prosthetic valve dysfunction, periprosthetic valvular regurgitation, or both. We report a case of a 41-year-old man who had a previous aortic valve and root replacement for acute proximal aortic dissection, now presenting with hemolytic anemia. This was a result of flow obstruction at the distal anastomosis of the aortic conduit by the presence of multiple dissection flaps resulting in severe flow turbulence. Although the pathology was at the blind spot for transesophageal echocardiography, the dissection flaps, the flow turbulence, and the degree of obstruction were well-demonstrated by this technique after careful manipulation of the probe and a high index of suspicion.
Aggarwal, Sanjeev; Delius, Ralph E; Walters, Henry L; L'Ecuyer, Thomas J
2012-01-01
This case report describes a toddler who developed a protein-losing enteropathy (PLE) 4 years after orthotopic heart transplantation (OHT). He was born with a hypoplastic left heart syndrome for which he underwent a successful Norwood procedure, a Hemi-Fontan palliation, and a Fontan palliation at 18 months of age. Fifteen months following the Fontan operation, he developed a PLE and Fontan failure requiring OHT. Four years after OHT, he developed a severe tricuspid regurgitation and a PLE. His PLE improved after tricuspid valve replacement. It is now 2 years since his tricuspid valve replacement and he remains clinically free of ascites and peripheral edema with a normal serum albumin level. His prosthetic tricuspid valve is functioning normally. © 2011 Wiley Periodicals, Inc.
Hu, Jia; Qian, Hong; Li, Ya-jiao; Gu, Jun; Zhao, Jing Janice; Zhang, Er-yong
2014-01-17
The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2)
Midterm Follow-Up of the Stentless Freedom Solo Bioprosthesis in 350 Patients.
Wollersheim, Laurens W; Li, Wilson W; Bouma, Berto J; Kaya, Abdullah; van Boven, Wim J; van der Meulen, Jan; de Mol, Bas A
2016-07-01
The stentless Freedom Solo aortic bioprosthesis is implanted supraannularly using one running suture line in the sinuses of Valsalva. We report our 9-year experience with this bioprosthesis. From April 2005 to July 2014, 350 consecutive patients at our institution underwent aortic valve replacement with the Freedom Solo bioprosthesis. Follow-up and echocardiographic data were collected retrospectively from referring cardiology centers. The mean age was 76 ± 6 years, 48% were male, and 46% underwent a concomitant procedure. Median EuroSCORE II was 3.0 (interquartile range, 1.9 to 4.9). Operative mortality was 5.1% for all procedures and 2.1% for isolated aortic valve replacement. The 1-, 5-, and 9-year overall survival was 92%, 74%, and 47%, respectively. At 6 years, freedom from structural valve deterioration and freedom from aortic valve reoperation were 98% and 96%, respectively. Prosthetic valve endocarditis occurred at a rate of 0.8% per patient-year. Permanent pacemaker implantation was necessary in 2.3% (n = 8), and moderate and severe prosthesis-patient mismatch occurred in 30 patients overall (9.6%). Postoperative maximum and mean valvular gradients were 17 mm Hg and 10 mm Hg, respectively, and remained stable during follow-up. Aortic valve replacement with the Freedom Solo is safe and has a low rate of permanent pacemaker implantations and prosthesis-patient mismatch. Survival is comparable to that with other aortic bioprostheses, and structural valve deterioration and aortic valve reoperation are infrequent during midterm follow-up. Hemodynamic performance is excellent, with low valvular gradients that remain stable during follow-up. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Poor clinical performance of the Wessex porcine heart valve bioprosthesis at nine years' follow up.
Hurlé, A.; Nistal, J. F.; Revuelta, J. M.
1997-01-01
OBJECTIVE: To assess the long term performance of the Wessex porcine bioprostheses implanted in a consecutive series of patients. DESIGN: A retrospective case series. PATIENTS: Between January 1985 and July 1991, 184 Wessex bioprostheses (78 mitral, 102 aortic, and 4 tricuspid) were implanted in 150 patients. The patients were 55% (83/150) male and 45% (67/150) female; mean age was 60 (SD 10) years. RESULTS: Hospital mortality was 9.3% (14/150). Total follow up was 696 patient-years (mean 4.7 years per patient). Linearised rates (events per 100 patient-years (SEM) for postoperative complications for patients with isolated mitral valve replacement, isolated aortic valve replacement, and multiple valve replacement were, respectively: late mortality: 4.7 (1.6), 3.3 (0.9), and 4.9 (1.9); thromboembolism: 5.8 (1.8), 3.0 (0.9), and 2.8 (1.4); valve thrombosis: 1.0 (0.7), 0.3 (0.3), and 0.7 (0.7); structural failure: 5.8 (1.7), 1.9 (0.7), and 7.1 (2.2). Actuarial freedom from complications at nine years (70% confidence interval) was: late mortality: 61 (9)%, 57 (13)%, and 59 (12)%; thromboembolism and valve thrombosis: 71 (9)%, 79 (6)%, and 81 (8)%; structural failure: 33 (14)%, 50 (16)%, and 12 (14)%; all valve related morbidity/mortality: 31 (10)%, 21 (11)%, and 7 (9)%. Stent fractures appeared in 11 of 17 explanted prostheses; actuarial freedom from stent fracture at nine years was 66 (12)%. CONCLUSIONS: The Wessex bioprosthesis is associated with high thrombogenicity, early structural dysfunction, and a high valve related morbidity/mortality which justifies very close follow up of patients fitted with them. Images PMID:9155609
Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet
2012-02-01
Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.
Lee, Justin Z; Tey, Kai R; Mizyed, Ahmad; Hennemeyer, Charles T; Janardhanan, Rajesh; Lotun, Kapildeo
2015-10-09
Left ventricular outflow tract (LVOT) obstruction and paravalvular leak (PVL) are relatively uncommon, but are serious complications of prosthetic valve replacement. We present a case that displays the unique therapeutic challenges of treating a patient who developed both LVOT obstruction and mitral PVL after undergoing surgical aortic and mitral valve replacement (MVR). We also describe the use of alcohol septal ablation and albumin-glutaraldehyde (BioGlue) for septal ablation to percutaneously treat the patient's LVOT obstruction, followed by use of an Amplatzer vascular plug for percutaneous closure of an antero-medial mitral PVL associated with severe regurgitation. Percutaneous interventional management of these entities may be considered as an initial therapeutic option, especially in high-risk patients with significant morbidity and mortality of repeat surgical operations.
Nagy, Mathias Thomas; Hla, Sann Minn; Keys, Graham Watson
2013-01-01
Streptococcus bovis is rare cause of late infections after total knee replacement (TKR). This report presents a case of confirmed late septic arthritis following TKR caused by S bovis that was further complicated with infective endocarditis resulting in aortic valve insufficiency in an immunecompetent patient. As an association between S bovis and gastrointestinal malignancies is suggested, a workup for such malignancies was performed that revealed non-malignant ulcers in patient's ascending colon. The patient is currently recovering from his aortic valve replacement surgery and is scheduled to have annual colonoscopies. His knee joint has improved; however, he developed constant pain because of underlying chronic infection in the affected joint and has difficulties mobilising. Therefore, a revision TKR is considered but postponed until he fully recovers from his heart valve surgery. PMID:23744853
Constitutive modeling of jugular vein-derived venous valve leaflet tissues.
Kaul, Nayyan; Huang, Hsiao-Ying Shadow
2017-11-01
Venous valve tissues, though used in vein reconstruction surgeries and bioprosthetic valves with moderate success, have not been extensively studied with respect to their structure. Their inherent anisotropic, non-linear behavior combined with severe diseases which affect veins, such as chronic venous insufficiency, warrant understanding the structure and material behavior of these tissues. Hence, before any bioprosthetic grafts may be used in place of tissues, it is of the utmost importance to understand the mechanical and structural properties of these tissues as this may lead to higher success rates for valve replacement surgeries. The longevity of the bioprosthetics may also increase if the manufactured grafts behave the same as native valves. Building on the scant information about the uniaxial and biaxial mechanical properties of jugular venous valves and wall tissues from previous studies, the current focus of our investigation lies in understanding the material behavior by establishing a phenomenological strain energy-based constitutive relation for the tissues. We used bovine veins to study the behavior of valve leaflet tissue and adjoining wall tissue (from the proximal and distal ends of the veins) under different biaxial testing protocols. We looked at the behavior of numerical partial derivatives of the strain energy to select a suitable functional form for the strain energy for wall and valve tissues. Using this strain energy descriptor, we determined the Cauchy stress and compared it with experimental results under additional sets of displacement-controlled biaxial testing protocols to find material specific model parameters by the Powell's method algorithm. Results show that whereas wall tissue strain energy can be explained using a polynomial non-linear function, the valve tissue, due to higher non-linearities, requires an exponential function. This study may provide useful information for the primary stages of bioprosthetic designs and replacement surgeries and may support future studies investigating structural models. It may also support the study of valvular diseases by providing a way to understand material properties and behavior and to form a continuum model when required for numerical analyses and computational simulations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.
Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas
2017-06-01
Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.
Leon, Martin B; Smith, Craig R; Mack, Michael J; Makkar, Raj R; Svensson, Lars G; Kodali, Susheel K; Thourani, Vinod H; Tuzcu, E Murat; Miller, D Craig; Herrmann, Howard C; Doshi, Darshan; Cohen, David J; Pichard, Augusto D; Kapadia, Samir; Dewey, Todd; Babaliaros, Vasilis; Szeto, Wilson Y; Williams, Mathew R; Kereiakes, Dean; Zajarias, Alan; Greason, Kevin L; Whisenant, Brian K; Hodson, Robert W; Moses, Jeffrey W; Trento, Alfredo; Brown, David L; Fearon, William F; Pibarot, Philippe; Hahn, Rebecca T; Jaber, Wael A; Anderson, William N; Alu, Maria C; Webb, John G
2016-04-28
Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).
Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian
2016-01-01
This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. PMID:27694613
Prosthetic Aortic Valves: Challenges and Solutions
Musumeci, Lucia; Jacques, Nicolas; Hego, Alexandre; Nchimi, Alain; Lancellotti, Patrizio; Oury, Cécile
2018-01-01
Aortic Valve Disease (AVD) is the most common Valvular Heart Disease (VHD), affecting millions of people worldwide. Severe AVD is treated in most cases with prosthetic aortic valve replacement, which involves the substitution of the native aortic valve with a prosthetic one. In this review we will discuss the different types of prosthetic aortic valves available for implantation and the challenges faced by patients, medical doctors, researchers and manufacturers, as well as the approaches that are taken to overcome them. PMID:29868612
"Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve).
Vavouranakis, Manolis; Vrachatis, Dimitrios A; Toutouzas, Konstantinos P; Chrysohoou, Christina; Stefanadis, Christodoulos
2010-11-05
Two techniques for correcting malpositioning occurring during percutaneous aortic valve replacement (PAVR) with the CoreValve ReValving™ System are described in this article. The "Removing and Reinserting Technique" was used in 2 patients, in whom the prosthesis was positioned too high. The "Snare Technique" was used in 1 patient, in whom the prosthesis was implanted too low. In all patients the aortic valve prosthesis was successfully re-implanted. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Mitral valve-sparing procedures and prosthetic heart valve failure: A case report
Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J
2009-01-01
Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993
Heart valve surgery - discharge
... weeks, or when you can easily climb 2 flights of stairs or walk a half-mile (800 ... vomiting or diarrhea You become pregnant or are planning to become pregnant Alternative Names Aortic valve replacement - ...
Lindman, Brian R; Maniar, Hersh S; Jaber, Wael A; Lerakis, Stamatios; Mack, Michael J; Suri, Rakesh M; Thourani, Vinod H; Babaliaros, Vasilis; Kereiakes, Dean J; Whisenant, Brian; Miller, D Craig; Tuzcu, E Murat; Svensson, Lars G; Xu, Ke; Doshi, Darshan; Leon, Martin B; Zajarias, Alan
2015-04-01
Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (P<0.001). Increasing severity of RV dysfunction as well as right atrial and RV enlargement were also associated with increased mortality (P<0.001). After multivariable adjustment, severe TR (hazard ratio, 3.20; 95% confidence interval, 1.50-6.82; P=0.003) and moderate TR (hazard ratio, 1.60; 95% confidence interval, 1.02-2.52; P=0.042) remained associated with increased mortality as did right atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether concomitant treatment of TR in operable but high-risk patients with aortic stenosis is warranted. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313. © 2015 American Heart Association, Inc.
Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K; Goncalves, Alexandra; Di Carli, Marcelo F; Rybicki, Frank J; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron
2016-01-01
3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Early Outcomes of Sutureless Aortic Valves
Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat
2016-01-01
Background In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time. PMID:27298793
Surgical treatment of functional ischemic mitral regurgitation.
Jensen, Henrik
2015-03-01
In many ways we are at a crossroad in terms of what constitutes optimal FIMR treatment: is CABG combined with mitral valve ring annuloplasty better than CABG alone in moderate FIMR? Is mitral valve repair really better than replacement? And does adding a valvular repair or subvalvular reverse remodeling procedure shift that balance? In the present thesis I aim to shed further light on these questions by addressing the current status and future perspectives of the surgical treatment of FIMR. CURRENT SURGICAL TREATMENT FOR FIMR. CABG alone: The overall impression from the literature is that patients are left with a high grade of persistent/recurrent FIMR from isolated CABG. CABG is most effective to treat FIMR in patients with viable myocardium (at least five viable segments) and absence of dyssynchrony between papillary muscles (< 60 ms). Mitral valve ring annuloplasty. A vast number of different designs are available to perform mitral valve ring annuloplasty with variations over the theme of complete/partial and rigid/semi-rigid/flexible. Also, the three-dimensional shape of the rigid and semi-rigid rings is the subject of great variation. A rigid or semi-rigid down-sized mitral valve ring annuloplasty is the most advocated treatment in chronic FIMR grade 2+ or higher. Combined CABG and mitral valve ring annuloplasty: CABG combined with mitral valve ring annuloplasty leads to reverse LV remodeling and reduced volumes. Despite this, the recurrence rate after combined CABG and mitral valve ring annuloplasty is 20-30% at 2-4 years follow-up. This is also true for studies strictly using down-sized mitral valve ring annuloplasty by two sizes. A number of preoperative risk factors to develop recurrent FIMR were identified, e.g. LVEDD > 65-70 mm, coaptation depth > 10 mm, anterior leaflet angle > 27-39.5°, posterior leaflet angle > 45° and interpapillary muscle distance > 20 mm. CABG alone vs. combined CABG and mitral valve ring annuloplasty: The current available literature, including three randomized studies and a meta analysis, indicate that combined CABG and mitral valve ring annuloplasty has no late survival difference compared with CABG alone, and early mortality might even be higher. Meanwhile, adding a mitral valve ring annuloplasty results in a lower NYHA functional class, most likely as a consequence of a lower incidence of persistent or recurrent FIMR. More randomized studies are being conducted to further address this topic. Mitral valve ring annuloplasty vs. mitral valve replacement. The early survival may be higher after repair compared with replacement, meanwhile, the literature is more ambiguous in terms of late survival advantages, and recent reports find no late survival advantage from repair over replacement. The recurrence rates after ring annuloplasty addressed above were also present in this subset of patients, whereas the incidence of recurrent FIMR after valve replacement is scarcely reported. There was an overall tendency of slightly higher incidence of reoperations after ring annuloplasty. The mitral valve annulus: Innovations in mitral valve ring annuloplasty: The latest innovation in mitral valve ring annuloplasty design includes adjustable rings, allowing adjustment of septo-lateral dimensions intra- or postoperatively. Minimally invasive ring annuloplasty using indirect coronary sinus devices, has been introduced, but so far have produced suboptimal results in terms of safety and efficacy. Also, first in man testing of direct percutaneous catheter based mitral annuloplasty techniques have been conducted. Leaflets and chordae: Direct repair techniques: Surgical methods have been developed to directly address the mitral valve leaflets and chordae tendineae to correct leaflet tethering in FIMR. Both the Alfieri stich and the minimally invasive MitraClip attaches the anterior and posterior leaflets, typically the A2-P2 region, to correct incomplete leaflet coaptation. Patch augmentation of the posterior leaflet in the P2-P3 region increases coaptation in the area most prone to cause FIMR. Chordal cutting of the secondary "strut" chordae releases the anterior leaflet from the tethering due to papillary muscle displacement and improves mitral valve geometry. The mitral subvalvular apparatus: Numerous subvalvular approaches to improve outcome in patients with FIMR have been introduced. They include very invasive techniques such as surgical ventricular restoration procedure, surgical techniques directly addressing the papillary muscle dis-placement, and beating heart procedures using transventricular and epicardial devices applied in a few minutes. The role of the transventricular and epicardial devices still remains to be defined and many of these devices seem to have a hard time ganing their footing in the clinical practise and until now only constitute a footnote in the surgical literature. Meanwhile, the current results with adjunct techniques to CABG and ring annuloplasty, such as the papillary muscle approximation technique introduced by Hvass et al and the papillary muscle relocation technique introduced by Kron et al and further developed by Langer et al are gaining continuing support in the surgical community since these techniques can be used with only little added time consumption but with very good clinical outcome.
Kabiri Rad, Hamid; Mazaheri, Mahta; Dehghani Firozabadi, Ali
Background: MicroRNAs (miRNAs) are implicated in various biological processes including anticoagulation. However, the modulation of miRNA by pharmacological intervention such as warfarin treatment in patients receiving warfarin has not been disclosed yet. The aim of this study work was to assess the effect of warfarin drug on expression level of mir-133a-3p in patients with mechanical heart valve replacement. Methods: In this research, the expression level of miRNA-133a-3p was analyzed in Peripheral Blood Mononuclear Cells (PBMCs) from mechanical valve replacement patients who had received warfarin for at least 3 months continuously. Quantitative RT-PCR method was used for this assay. Results: Our findings indicated a significant diffrence between the rate of miR-133a-3p expression in individuals receiving warfarin and the control group (p<0.01). There was also a statistically significant difference in miR-133a-3p expression in patients with different ages (p<0.05) suggesting that the rate of miR-133a-3p expression in persons receiving warfarin is related to age. However, other variables like warfarin dose, International Normalized Ratio (INR), gender, and Body Mass Index (BMI) were not significantly effective on the miR-133a-3p experssion rate in individuals receving warfarin. Conclusion: Based on our results, it can be concluded that miR-133a-3p is involved in the coagulation pathway. The recent result indicates that warfarin affects the expression of miR-133a. This expression may be potentially important for treatment by anticoagulants. Awareness of the time course of miRNA expression profile can improve efficiency of response to warfarin. PMID:29296264
Zhang, Jing; Fan, Guangpu; Zhao, Hui; Wang, Xu; Wang, Zhiwei; Zhang, Peide; Wang, Wei
2016-12-01
Objective To compare the aortic diameter after isolated aortic valve replacement (AVR) in patients with a bicuspid (BAV) or tricuspid aortic valve (TAV) and an initially normal ascending aorta. Methods Patients with an ascending aortic diameter of < 45 mm who had undergone isolated AVR were studied. Ultrasonic cardiographic measurements of the ascending aortic diameter made pre- and postoperatively and follow-up data concerning adverse aortic events and death were analyzed. Results A total of 613 patients were included in this retrospective study; of these, 211 had a BAV and 402 had a TAV. In both groups, the ascending aorta significantly expanded but was non-aneurysmal during follow-up; however, the difference between the two groups was not significant. Cox regression analysis showed no significant effect associated with the presence of a BAV on adverse aortic events or death. Conclusion Dilatation of the ascending aorta was observed after AVR in both groups, but was not more pronounced in patients with a BAV. Long-term follow-up for ascending aortic aneurysm is necessary after AVR in both patients with a BAV and those with a TAV.
Zhang, Jing; Fan, Guangpu; Zhao, Hui; Wang, Xu; Wang, Zhiwei; Zhang, Peide
2016-01-01
Objective To compare the aortic diameter after isolated aortic valve replacement (AVR) in patients with a bicuspid (BAV) or tricuspid aortic valve (TAV) and an initially normal ascending aorta. Methods Patients with an ascending aortic diameter of < 45 mm who had undergone isolated AVR were studied. Ultrasonic cardiographic measurements of the ascending aortic diameter made pre- and postoperatively and follow-up data concerning adverse aortic events and death were analyzed. Results A total of 613 patients were included in this retrospective study; of these, 211 had a BAV and 402 had a TAV. In both groups, the ascending aorta significantly expanded but was non-aneurysmal during follow-up; however, the difference between the two groups was not significant. Cox regression analysis showed no significant effect associated with the presence of a BAV on adverse aortic events or death. Conclusion Dilatation of the ascending aorta was observed after AVR in both groups, but was not more pronounced in patients with a BAV. Long-term follow-up for ascending aortic aneurysm is necessary after AVR in both patients with a BAV and those with a TAV. PMID:27484890
Prosthetic valve sparing aortic root replacement: an improved technique.
Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G
2008-10-01
We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.
Adapting to living with a mechanical aortic heart valve: a phenomenographic study.
Oterhals, Kjersti; Fridlund, Bengt; Nordrehaug, Jan Erik; Haaverstad, Rune; Norekvål, Tone M
2013-09-01
To describe how patients adapt to living with a mechanical aortic heart valve. Aortic valve replacement with a mechanical prosthesis is preferred for patients with life expectancy of more than 10 years as they are more durable than bioprosthetic valves. Mechanical valves have some disadvantages, such as higher risk of thrombosis and embolism, increased risk of bleeding related to lifelong oral anticoagulation treatment and noise from the valve. An explorative design with a phenomenographic approach was employed. An explorative design with a phenomenographic approach was applied. Interviews were conducted over 4 months during 2010-2011 with 20 strategically sampled patients, aged 24-74 years having undergone aortic valve replacement with mechanical prosthesis during the last 10 years. Patients adapted to living with a mechanical aortic heart valve in four ways: 'The competent patient' wanted to stay in control of his/her life. 'The adjusted patient' considered the implications of having a mechanical aortic valve as part of his/her daily life. 'The unaware patient' was not aware of warfarin-diet-medication interactions. 'The worried patient' was bothered with the oral anticoagulation and annoyed by the sound of the valve. Patients moved between the different ways of adapting. The oral anticoagulation therapy was considered the most troublesome consequence, but also the sound of the valve was difficult to accept. Patient counselling and adequate follow-up can make patients with mechanical aortic heart valves more confident and competent to manage their own health. We recommend that patients should participate in a rehabilitation programme following cardiac surgery. © 2013 Blackwell Publishing Ltd.
Crowhurst, James A; Poon, Karl K; Murdoch, Dale; Incani, Alexander; Raffel, Owen C; Liddicoat, Annelise; Walters, Darren
2015-12-01
Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.
Re-do aortic root replacement after an allograft aortic root replacement.
Vrtik, Marian; Tesar, Peter J
2009-10-01
Structural degeneration of allograft aortic root is a global process. In addition to valvular degeneration, the allograft wall calcification poses a risk of systemic calcific embolization and late phase anastomotic aneurysm formation and rupture (anecdotal). Furthermore, the valve annulus is often small, and the tissues are rigid making the implantation of an adequately sized prosthesis within the allograft wall difficult. To avoid these issues, we routinely perform re-do aortic root replacement with either a mechanical valve conduit or bio-root composite graft. The technique has been successfully used in 22 consecutive patients with no operative mortality and minimal morbidity.
Bourguignon, Thierry; Espitalier, Fabien; Pantaleon, Clémence; Vermes, Emmanuelle; El-Arid, Jean Marc; Loardi, Claudia; Karam, Elias; Candolfi, Pascal; Ivanes, Fabrice; Aupart, Michel
2018-02-12
Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. From 1984 to 2010, 148 Carpentier-Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. The mean follow-up period was 8.6 ± 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 ± 4%, 53 ± 6% and 31 ± 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 ± 5%, 47 ± 7% and 19 ± 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 ± 4%, 50 ± 6% and 25 ± 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 ± 5%. Expected valve durability was 14.2 years for this age group. In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Response characteristic of high-speed on/off valve with double voltage driving circuit
NASA Astrophysics Data System (ADS)
Li, P. X.; Su, M.; Zhang, D. B.
2017-07-01
High-speed on/off valve, an important part of turbocharging system, its quick response has a direct impact on the turbocharger pressure cycle. The methods of improving the response characteristic of high speed on/off valve include increasing the magnetic force of armature and the voltage, decreasing the mass and current of coil. The less coil number of turns, the solenoid force is smaller. The special armature structure and the magnetic material will raise cost. In this paper a new scheme of double voltage driving circuit is investigated, in which the original driving circuit of high-speed on/off valve is replaced by double voltage driving circuit. The detailed theoretical analysis and simulations were carried out on the double voltage driving circuit, it showed that the switching time and delay time of the valve respectively are 3.3ms, 5.3ms, 1.9ms and 1.8ms. When it is driven by the double voltage driving circuit, the switching time and delay time of this valve are reduced, optimizing its response characteristic. By the comparison related factors (such as duty cycle or working frequency) about influences on response characteristic, the superior of double voltage driving circuit has been further confirmed.
Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results.
Vrandecic, M; Gontijo Filho, B; Fantini, F; Barbosa, J; Martins, I; de Oliveira, O C; Martins, C; Max, R; Drumond, L; Oliveira, C; Ferrufino, A; Alcocer, E; Silva, J A; Vrandecic, E
1998-03-01
The study aimed to determine the clinical performance of bovine pericardial aldehyde-treated products alone or in combination with aortic leaflets of porcine origin. These included a composite porcine stentless aortic valve attached to a scalloped pericardial tube (BSAV), and valved and non-valved bovine pericardial conduits for use in left-sided heart lesions (BPG). For BSAV grafts, between January 1990 and August 1996, 163 patients (119 males) had their aortic valves replaced by SJM Biocor BASV. Mean age was 37.9 +/- 17.6 years (range: 1 to 76 years). Rheumatic heart disease sequelae (n = 72) and replacement of a prosthetic heart valve (n = 46) were predominant. Preoperative NYHA functional class showed 90 patients (55.2%) in class III and 50 (30.7%) in class IV. BPVC and NVPC grafts were used in 166 patients: acute aortic dissection was the main indication in 52 (31.3%) and chronic in 36 (21/7%). The ascending aorta was involved in 141 patients (84.9%); grafts were seldom used at other sites. In most patients the graft implanted was either a non-valved (n = 79) or a valved (n = 75) pericardial conduit. Twelve patients had a localized lesion and required a patch repair. For BASV grafts, the non-valve-related hospital mortality rate was 4.9%. There were 14.7% non-fatal complications with full recovery of all patients. Mean follow up in 141 patients was 3.0 +/- 1.4 years (range: 1 month to 7.2 years); 14 patients were lost to follow up. Late, non-conduit-related, mortality occurred in seven patients (4.9%). Eight patients underwent reoperation. The current clinical follow up of 127 patients has shown 118 (92.9%) with competent valves and nine (7.0%) with mild stable aortic insufficiency. For BPVC and NVPC grafts, hospital mortality rate was 16.9%, death being related to poor preoperative clinical condition. Postoperative follow up was accomplished in 125 patients; reoperation was necessary in seven patients. Histology showed good tissue preservation up to five years; echocardiography revealed satisfactory findings. No valved conduit had to be reoperated for valve or pericardial tissue wear. Clinical results of left-sided heterologous pericardial grafts have shown excellent performance over time. The BASV (over seven years) and BPVC and NVPC (eight years) have demonstrated superior results as aortic valves alone or in combination with a pericardial conduit.
Electrodynamic actuators for rocket engine valves
NASA Technical Reports Server (NTRS)
Fiet, O.; Doshi, D.
1972-01-01
Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.
Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.
Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland
2015-09-01
A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Surgical treatment of Behçet's disease involving aortic regurgitation.
Ando, M; Kosakai, Y; Okita, Y; Nakano, K; Kitamura, S
1999-12-01
Behçet's disease involving aortic regurgitation is rare, and prosthetic valve detachment after aortic valve replacement is one of the most serious complications reported. We investigated the surgical results in 10 patients with aortic regurgitation caused by Behçet's disease. Between 1981 and 1997, 10 patients with aortic regurgitation secondary to Behçet's disease had surgery. There were 8 men and 2 women, and their ages ranged from 33 to 60 years (mean, 46+/-8 years). The surgical procedures for aortic regurgitation were aortic valve replacement in 6 patients and Bentall type operation in 4. No patient died during the hospital stay. The follow-up periods ranged from 11 to 185 months (mean, 87 months). Two patients died during the follow-up period. The acturial survival rate was 89% at 5 years and 67% at 10 years. Prosthetic valve detachment or suture detachment requiring redo operation occurred in 4 patients, 3 of whom had redo operations twice. Four patients had a composite graft replacement, and 1 patient died after the operation. No prosthetic valve detachment was noted in 64% of the patients at 5 years and in 43% at 10 years. The rate of prosthetic valve detachment was 40% (4 of 10 patients), with a higher incidence in patients with Behçet's disease than in those treated during the same period at the same hospital for aortitis caused by other diseases. Surgical techniques for treatment of this condition should be modified to improve the surgical outcome in these patients.
Kim, Jong Hun; Kim, Tae Youn; Choi, Jong Bum; Kuh, Ja Hong
2017-01-01
Patients requiring redo cardiac surgery for diseased heart valves other than mitral valves may show increased pressure gradients and reduced valve areas of previously placed mechanical mitral valves due to subvalvular pannus formation. We treated four women who had mechanical mitral valves inserted greater than or equal to 20 years earlier and who presented with circular pannus that protruded into the lower margin of the valve ring but did not impede leaflet motion. Pannus removal improved the haemodynamic function of the mitral valve. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Takamatsu, Masanori; Hirotani, Takashi; Ohtsubo, Satoshi; Saito, Sumikatsu; Takeuchi, Shigeyuki; Hasegawa, Tasuku; Endo, Ayaka; Yamasaki, Yu; Hayashida, Kentaro
2015-06-01
A 67-year-old man on chronic hemodialysis was admitted with worsening congestive heart failure due to critical aortic stenosis. Echocardiography showed severe aortic stenosis with a valve area of 0.67 cm2 and an ejection fraction of 0.31. Cardiac catheterization revealed severe pulmonary hypertension with pulmonary artery pressures of 62/32 mmHg. In the middle of cardiac catheterization, the systolic pressure declined to 60 mmHg due to cardiogenic shock. Dopamine hydrochloride and dobutamine hydrochloride infusions were necessary to maintain a systolic pressure greater than 80 mmHg. Balloon aortic valvuloplasty was urgently performed. The patient's symptoms rapidly resolved except for angina on exertion. One month later, elective aortic valve replacement was performed. The postoperative course was uneventful and the he was discharged on the 60th postoperative day. A follow-up echocardiogram 6 months postoperatively revealed normal prosthetic valve function and an ejection fraction of 0.6.
Aortic valve replacement during acute rheumatic fever.
Khan, A; Chi, S; Gonzalez-Lavin, L
1978-07-01
Emergency aortic valve replacement was performed during an attack of acute rheumatic fever in a 12-year-old black boy. He had an uneventful recovery and has remained asymptomatic 27 months after operation. In the light of this experience and that of others, one might conclude that the decision to operate on these patients should be based on the severity of the haemodynamic derangement rather than on the state of activity in the rheumatic process.
Transcatheter Aortic Valve Replacement: a Kidney’s Perspective
Cheungpasitporn, Wisit; Thongprayoon, Charat; Kashani, Kianoush
2016-01-01
Transcatheter aortic valve replacement (TAVR) has now emerged as a viable treatment option for high-risk patients with severe aortic stenosis (AS) who are not suitable candidates for surgical aortic valve replacement (SAVR). Despite encouraging published outcomes, acute kidney injury (AKI) is common and lowers the survival of patients after TAVR. The pathogenesis of AKI after TAVR is multifactorial including TAVR specific factors such as the use of contrast agents, hypotension during rapid pacing, and embolization; preventive measures may include pre-procedural hydration, limitation of contrast dye exposure, and avoidance of intraprocedural hypotension. In recent years, the number of TAVR performed worldwide has been increasing, as well as published data on renal perspectives of TAVR including AKI, chronic kidney disease, end-stage kidney disease, and kidney transplantation. This review aims to present the current literature on the nephrology aspects of TAVR, ultimately to improve the patients’ quality of care and outcomes. PMID:27069960
Evolving trends in aortic valve replacement: A statewide experience.
Kim, Karen M; Shannon, Francis; Paone, Gaetano; Lall, Shelly; Batra, Sanjay; Boeve, Theodore; DeLucia, Alphonse; Patel, Himanshu J; Theurer, Patricia F; He, Chang; Clark, Melissa J; Sultan, Ibrahim; Deeb, George Michael; Prager, Richard L
2018-06-17
Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) for the treatment of aortic stenosis in patients at intermediate, high, and extreme risk for mortality from SAVR. We examined recent trends in aortic valve replacement (AVR) in Michigan. The Michigan Society of Thoracic and Cardiovascular Surgeons Quality Collaborative (MSTCVS-QC) database was used to determine the number of SAVR and TAVR cases performed from January 2012 through June 2017. Patients were divided into low, intermediate, high, and extreme risk groups based on STS predicted risk of mortality (PROM). TAVR patients in the MSTCVS-QC database were also matched with those in the Transcatheter Valve Therapy Registry to determine their Heart Team-designated risk category. During the study period 9517 SAVR and 4470 TAVR cases were performed. Total annual AVR volume increased by 40.0% (from 2086 to 2920), with a 13.3% decrease in number of SAVR cases (from 1892 to 1640) and a 560% increase in number of TAVR cases (from 194 to 1280). Greater than 90% of SAVR patients had PROM ≤8%. While >70% of TAVR patients had PROM ≤ 8%, they were mostly designated as high or extreme risk by a Heart Team. During the study period, SAVR volume gradually declined and TAVR volume dramatically increased. This was mostly due to a new group of patients with lower STS PROM who were designated as higher risk by a Heart Team due to characteristics not completely captured by the STS PROM score. © 2018 Wiley Periodicals, Inc.
Madl, Amy K; Hollins, Dana M; Devlin, Kathryn D; Donovan, Ellen P; Dopart, Pamela J; Scott, Paul K; Perez, Angela L
2014-08-01
Exposures to airborne asbestos during the removal and installation of internal gaskets and packing associated with a valve overhaul were characterized and compared to published data according to different variables (e.g., product, equipment, task, tool, setting, duration). Personal breathing zone and area samples were collected during twelve events simulating gasket and packing replacement, clean-up and clothing handling. These samples were analyzed using PCM and TEM methods and PCM-equivalent (PCME) airborne asbestos concentrations were calculated. A meta-analysis was performed to compare these data with airborne asbestos concentrations measured in other studies involving gaskets and packing. Short-term mechanic and assistant airborne asbestos concentrations during valve work averaged 0.013f/cc and 0.008f/cc (PCME), respectively. Area samples averaged 0.008f/cc, 0.005f/cc, and 0.003f/cc (PCME) for center, bystander, and remote background, respectively. Assuming a tradesman conservatively performs 1-3 gasket and/or packing replacements daily, an average 8-h TWA was estimated to be 0.002-0.010f/cc (PCME). Combining these results in a meta-analysis of the published exposure data showed that the majority of airborne asbestos exposures during work with gaskets and packing fall within a consistent and low range. Significant differences in airborne concentrations were observed between power versus manual tools and removal versus installation tasks. Airborne asbestos concentrations resulting from gasket and packing work during a valve overhaul are consistent with historical exposure data on replacement of asbestos-containing gasket and packing materials involving multiple variables and, in nearly all plausible scenarios, result in average airborne asbestos concentrations below contemporaneous occupational exposure limits for asbestos. Copyright © 2014 Elsevier Inc. All rights reserved.
Cerebral Aneurysm from Cardiobacterium hominis Endocarditis.
Glucksman, Aaron; Naut, Edgar
2016-05-01
A 43-year-old male with a history of bioprosthetic aortic valve replacement and tricuspid valve annuloplasty presented with vertigo and was found to have an acute infarct in the left superior cerebellum, as well as a left-middle cerebral artery mycotic aneurysm. Blood cultures grew Cardiobacterium hominis and bioprosthetic aortic valve vegetation was found on transthoracic echocardiogram.
Wiley, Zanthia; Woodworth, Michael H; Jacob, Jesse T; Lockhart, Shawn R; Rouphael, Nadine G; Gullett, Jonathan C; Guarner, Jeannette; Workowski, Kimberly
2017-01-01
A patient who never resided in an endemic area for dimorphic fungi was diagnosed with Histoplasma capsulatum endocarditis. His diagnosis was suggested by yeast and hyphae on cardiac valve tissue pathology. Isavuconazole was an optimal therapeutic option due to renal dysfunction and anticoagulation with warfarin for mechanical valve replacement.
Wiley, Zanthia; Woodworth, Michael H; Jacob, Jesse T; Lockhart, Shawn R; Rouphael, Nadine G; Gullett, Jonathan C; Guarner, Jeannette
2017-01-01
Abstract A patient who never resided in an endemic area for dimorphic fungi was diagnosed with Histoplasma capsulatum endocarditis. His diagnosis was suggested by yeast and hyphae on cardiac valve tissue pathology. Isavuconazole was an optimal therapeutic option due to renal dysfunction and anticoagulation with warfarin for mechanical valve replacement. PMID:29255737
Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten
2017-01-01
Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.
Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V
2015-03-01
The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Posterior leaflet preservation during mitral valve replacement for rheumatic mitral stenosis.
Djukić, P L; Obrenović-Kirćanski, B B; Vranes, M R; Kocica, M J; Mikić, A Dj; Velinović, M M; Kacar, S M; Kovacević, N S; Parapid, B J
2006-01-01
Mitral valve replacement with posterior leaflet preservation was shown beneficial for postoperative left vetricular (LV) performance in patients with mitral regurgitation. Some authors find it beneficial even for the long term LV function. We investigated a long term effect of this technique in patients with rheumatic mitral stenosis. We studied 20 patents with mitral valve replacement due to rheumatic mitral stenosis, in the period from January 1988 to December 1989. In group A (10 patients) both leaflets and coresponding chordal excision was performed, while in group B (10 patients) the posterior leaflet was preserved. In all patients a Carbomedics valve was inserted. We compared clinical pre and postoperative status, as well as hemodynamic characteristics of the valve and left ventricle in both groups. Control echocardiographyc analysis included: maximal (PG) and mean (MG) gradients; effective valve area (AREA); telediastolic (TDV) and telesystolic (TSV) LV volume; stroke volume (SV); ejection fraction (EF); fractional shortening (FS) and segmental LV motion. The mean size of inserted valve was 26.6 in group A and 27.2 in group B. Hemodynamic data: PG (10.12 vs 11.1); MG (3.57 vs 3.87); AREA (2.35 vs 2.30); TDV 126.0 vs 114.5); TSV (42.2 vs 36.62); SV (83.7 vs 77.75); EF (63.66 vs 67.12); FS (32.66 vs 38.25). Diaphragmal segmental hypokinesis was evident in one patient from group A and in two patients from group B. In patients with rheumatic stenosis, posterior leaflet preservation did not have increased beneficial effect on left ventricular performance during long-term follow-up. An adequate posterior leaflet preservation does not change hemodynamic valvular characteristics even after long-term follow-up.
Paradis, Jean-Michel; George, Isaac; Kodali, Susheel
2013-09-01
We report the case of an 81-year-old woman with symptomatic severe aortic stenosis, extremely significant peripheral arterial disease, and obstructive coronary artery disease who underwent percutaneous coronary intervention via a transaxillary conduit immediately before a trans-apical transcatheter aortic valve replacement performed with a transfemoral device. After deployment of the transcatheter heart valve, there was a left main coronary obstruction and the patient required an emergent PCI. This multifaceted case clearly underlines the importance of a well functioning heart team including the interventional cardiologist, the cardiovascular surgeon, and the echocardiographer. Copyright © 2013 Wiley Periodicals, Inc.
Al-Khadra, Yasser; Darmoch, Fahed; Baibars, Motaz; Kaki, Amir; Fanari, Zaher; Alraies, M Chadi
2018-05-17
The concomitant presence of mitral stenosis (MS) in the setting of symptomatic aortic stenosis represent a clinical challenge. Little is known regarding the outcome of mitral stenosis (MS) patients undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). Therefore, we sought to study the outcome of MS patients undergoing aortic valve replacement (AVR). Using weighted data from the National Inpatient Sample (NIS) database between 2011 and 2014, we identified patients who were diagnosed with MS. Patients who had undergone TAVR as a primary procedure were identified and compared to patients who had SAVR. Univariate and multivariate logistic regression analysis were performed for the outcomes of in-hospital mortality, length of stay (LOS), blood transfusion, postprocedural hemorrhage, vascular, cardiac and respiratory complications, permanent pacemaker placement (PPM), postprocedural stroke, acute kidney injury (AKI), and discharge to an outside facility. A total of 4524 patients were diagnosed with MS, of which 552 (12.2%) had TAVR and 3972 (87.8%) had SAVR. TAVR patients were older (79.9 vs 70.0) with more females (67.4% vs 60.0%) and African American patients (7.7% vs 7.1%) (P < 0.001). In addition, the TAVR group had more comorbidities compared to SAVR in term of coronary artery disease (CAD), congestive heart failure (CHF), chronic lung disease, hypertension (HTN), chronic kidney disease (CKD), and peripheral vascular disease (PVD) (P < 0.001 for all). Using Multivariate logistic regression, and after adjusting for potential risk factors, TAVR patients had lower in-hospital mortality (7.9% vs 8.1% adjusted Odds Ratio [aOR], 0.615; 95% confidence interval [CI], 0.392-0.964, P = 0.034), shorter LOS. Also, TAVR patients had lower rates of cardiac and respiratory complications, PPM, AKI, and discharge to an outside facility compared with the SAVR group. In patients with severe aortic stenosis and concomitant mitral stenosis, TAVR is a safe and attractive option for patients undergoing AVR with less complications compared with SAVR. © 2018, Wiley Periodicals, Inc.
14 CFR 67.211 - Cardiovascular.
Code of Federal Regulations, 2011 CFR
2011-01-01
... any of the following: (a) Myocardial infarction; (b) Angina pectoris; (c) Coronary heart disease that...) Cardiac valve replacement; (e) Permanent cardiac pacemaker implantation; or (f) Heart replacement. ...
14 CFR 67.211 - Cardiovascular.
Code of Federal Regulations, 2014 CFR
2014-01-01
... any of the following: (a) Myocardial infarction; (b) Angina pectoris; (c) Coronary heart disease that...) Cardiac valve replacement; (e) Permanent cardiac pacemaker implantation; or (f) Heart replacement. ...
14 CFR 67.211 - Cardiovascular.
Code of Federal Regulations, 2012 CFR
2012-01-01
... any of the following: (a) Myocardial infarction; (b) Angina pectoris; (c) Coronary heart disease that...) Cardiac valve replacement; (e) Permanent cardiac pacemaker implantation; or (f) Heart replacement. ...
14 CFR 67.211 - Cardiovascular.
Code of Federal Regulations, 2013 CFR
2013-01-01
... any of the following: (a) Myocardial infarction; (b) Angina pectoris; (c) Coronary heart disease that...) Cardiac valve replacement; (e) Permanent cardiac pacemaker implantation; or (f) Heart replacement. ...
Disc erosion in Models 103 and 104 of Beall mitral valve prostheses
Gómez, Ricardo; Verduras, María José; Lopez-Quintana, Alfonso; Riera, Luis; Zerolo, Ignacio; Martinez-Bordiu, Cristóbal
1981-01-01
Three cases of severe disc variance and erosion of the Teflon-disc Beall mitral valve prosthesis (Models 103 and 104) are reported. In two patients, the Beall mitral valves were excised and replaced with two Björk-Shiley mitral valves. The remaining patient did not survive, and at autopsy, the lens was found at the aortic bifurcation level. Because of this potentially lethal complication, careful follow-up of patients with Beall mitral valve prostheses (Models 103 and 104) is recommended. Images PMID:15216211
Abdel-Wahab, Mohamed; Neumann, Franz-Josef; Mehilli, Julinda; Frerker, Christian; Richardt, Doreen; Landt, Martin; Jose, John; Toelg, Ralph; Kuck, Karl-Heinz; Massberg, Steffen; Robinson, Derek R; El-Mawardy, Mohamed; Richardt, Gert
2015-08-18
The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. The investigator-initiated trial randomized 241 high-risk patients with symptomatic severe aortic stenosis and anatomy suitable for treatment with both balloon- and self-expandable transcatheter heart valves to transfemoral transcatheter aortic valve replacement with either device. Patients were followed-up for 1 year, with assessment of clinical outcomes and echocardiographic evaluation of valve function. At 1 year, the rates of death of any cause (17.4% vs. 12.8%; relative risk [RR]: 1.35; 95% confidence interval [CI]: 0.73 to 2.50; p = 0.37) and of cardiovascular causes (12.4% vs. 9.4%; RR: 1.32; 95% CI: 0.63 to 2.75; p = 0.54) were not statistically significantly different in the balloon- and self-expandable groups, respectively. The frequencies of all strokes (9.1% vs. 3.4%; RR: 2.66; 95% CI: 0.87 to 8.12; p = 0.11) and repeat hospitalization for heart failure (7.4% vs. 12.8%; RR: 0.58; 95% CI: 0.26 to 1.27; p = 0.19) did not statistically significantly differ between the 2 groups. Elevated transvalvular gradients during follow-up were observed in 4 patients in the balloon-expandable group (3.4% vs. 0%; p = 0.12); all were resolved with anticoagulant therapy, suggesting a thrombotic etiology. More than mild paravalvular regurgitation was more frequent in the self-expandable group (1.1% vs. 12.1%; p = 0.005). Despite the higher device success rate with the balloon-expandable valve, 1-year follow-up of patients in CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT Trial), with limited statistical power, revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with both balloon- and self-expandable prostheses that were not statistically significantly different. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial; NCT01645202). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Valve repair in aortic regurgitation without root dilatation--aortic valve repair.
Lausberg, H F; Aicher, D; Kissinger, A; Langer, F; Fries, R; Schäfers, H-J
2006-02-01
Aortic valve repair was established in the context of aortic root remodeling. Variable results have been reported for isolated valve repair. We analyzed our experience with isolated valve repair and compared the results with those of aortic root remodeling. Between October 1995 and August 2003, isolated repair of the aortic valve was performed in 83 patients (REP), remodeling of the aortic valve in 175 patients (REMO). The demographics of the two groups were comparable (REP: mean age 54.4 +/- 20.7 yrs, male-female ratio 2.1 : 1; REMO: mean age 60.8 +/- 13.6 yrs, male-female ratio 2.4 : 1; p = ns). In both groups the number of bicuspid valves was comparable (REP: 41 %, REMO: 32 %; p = ns). All patients were followed by echocardiography for a cumulative follow-up of 8204 patient months (mean 32 +/- 23 months). Overall in-hospital mortality was 2.4 % in REP and 4.6 % in REMO ( p = 0.62). Systolic gradients were comparable in both groups (REP: 5.8 +/- 2.2, REMO: 6.5 +/- 3.1 mm Hg, p = 0.09). The mean degree of aortic regurgitation 12 months postoperatively was 0.8 +/- 0.7 after REP and 0.7 +/- 0.7 after REMO ( p = 0.29). Freedom from significant regurgitation (> or = II degrees ) after 5 years was 86 % in REP and 89 % in REMO ( p = 0.17). Freedom from re-operation after 5 years was 94.4 % in REP and 98.2 % in REMO ( p = 0.33). Aortic regurgitation without concomitant root dilatation can be treated effectively by aortic valve repair. The functional results are equivalent to those obtained with valve-preserving root replacement. Aortic valve repair appears to be an alternative to valve replacement in aortic regurgitation.
Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk
2013-07-01
The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.
Aortic valve replacement during acute rheumatic fever.
Khan, A; Chi, S; Gonzalez-Lavin, L
1978-01-01
Emergency aortic valve replacement was performed during an attack of acute rheumatic fever in a 12-year-old black boy. He had an uneventful recovery and has remained asymptomatic 27 months after operation. In the light of this experience and that of others, one might conclude that the decision to operate on these patients should be based on the severity of the haemodynamic derangement rather than on the state of activity in the rheumatic process. Images PMID:687481
Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian
2016-12-01
This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. © The Author(s) 2016.
Assessment of quality of life in patients after surgical and transcatheter aortic valve replacement.
Tokarek, Tomasz; Siudak, Zbigniew; Dziewierz, Artur; Sobczyński, Robert; Zasada, Wojciech; Sorysz, Danuta; Olszewska-Wityńska, Katarzyna; Bryniarski, Krzysztof; Krawczyk-Ożóg, Agata; Żabówka, Anna; Sadowski, Jerzy; Dudek, Dariusz
2016-09-01
Transcatheter aortic valve implantation (TAVI) and minimally invasive aortic valve replacement (mini-thoracotomy, mini-sternotomy, MIAVR) have become an appealing alternative to conventional surgical (SAVR) treatment of severe aortic stenosis (AS) in high-risk patients. Aim of the study was to evaluate the quality of life (QoL) in patients with AS and treated with transfemoral TAVI, SAVR, mini-thoracotomy and mini-sternotomy. One hundred and seventy-three patients with symptomatic AS were enrolled in 2011-2013. TAVI group consisted of 39 patients (22.5%), mini-sternotomy was performed in 44 patients (25.5%), mini-thoracotomy in 50 (29%), and AVR in 40 patients (23%). QoL was assessed perioperatively, 12 and 24 months after aortic valve replacement (AVR) by Minnesota Living with Heart Failure Questionnaire (MLHFQ) and EQ-5D-3L. Median follow-up was 583.5 (IQR: 298-736) days. Improvement of health status after procedure in comparison with pre-operative period was significantly more often reported after TAVI in perioperative period (90.3%; P = 0.004) and 12 months after procedure (100%, P = 0.02). Global MLHFQ, physical and emotional dimension score at 30-day from AVR presented significant improvement after TAVI in comparison with surgical methods (respectively: 8.3(±8.6), P = 0.003; 4.1(±5.9), P = 0.01; 1.5(±2.6), P = 0.005). Total MLHFQ score was significantly lower (better outcome) in TAVI patients 1 year after procedure (4.8(±6.8), P = 0.004), no differences in somatic and emotional component were found. No differences were found in MLHFQ score 24 months after AVR. Data from EQ-D5-3L questionnaire demonstrated significant improvement of QoL at 30-day follow-up after TAVI in comparison with surgical methods (1.2(±1.7), P = 0.0008). TAVI improves QoL in perioperative and 12 months observation in comparison with mini-thoracotomy, mini-sternotomy and SAVR. Improvement in QoL was obtained in both generic and disease specific questionnaires. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to appurtenances, such as fender attachments, lighting brackets, ladder brackets; and (2) Replacement..., lighting brackets, ladder brackets; and (2) Replacement of components such as valves, vents, and fittings...
[Mitral valve endocarditis after Turkish "Festival of Sacrifice"].
Blaich, A; Fasel, D; Kaech, C; Frei, R
2011-09-01
Erysipelothrix rhusiopathiae is the causative agent of swine erysipelas. Systemic infections caused by E. rhusiopathiae are rare, but often (90%) associated with endocarditis. In about 60% of cases endocarditis develops on normal heart valves, and despite appropriate antibiotic therapy about one-third of the patients requires valve replacement. We report the case of a housewife, who developed a mitral valve endocarditis due to E. rhusiopathiae after preparing meat for the Turkish "Festival of Sacrifice".
Testing of RPMI-1640 as a Nutrient Medium for Fresh Semilunar Valve Storage.
1979-01-01
familiarization with cage life, canine distemper and hepatitis vaccinations, worming for internal parasites, and obtain one normal complete blood count. Atropine...human valves. If these results are similar to this canine study, a more realistic evaluation can be made as to whether the best tissue for heart valve...replacement is from live tissue of human allografts or dead tissue of procine xenografts. I SUMMARY The medium selected to store canine heart valves
Transcatheter aortic valve replacement
... fully will restrict blood flow. This is called aortic stenosis. If there is also a leak, it is ... TAVR is used for people with severe aortic stenosis who aren't ... valve . In adults, aortic stenosis usually occurs due to calcium ...
Progression of Tricuspid Regurgitation after Mitral Valve Replacement for Rheumatic Heart Disease.
Q Tri, Ho H; Vinh, Pham N
2017-05-01
Progression of tricuspid regurgitation (TR) may occur after mitral valve replacement (MVR). The study aim was to define the independent predictors for new severe TR after MVR to treat rheumatic heart disease. A total of 413 patients (177 men, 236 women; mean age 40.9 ± 9.2 years) with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair at the authors' institute between 1995 and 2005, who did not have preoperative severe TR, were followed for at least one year postoperatively. Survival without severe TR was estimated using the Kaplan-Meier method. Independent predictors for new severe TR were identified using multiple Cox regression analysis. During a median follow up of 13 years there were two late deaths, and 46 patients (11.1%) had new severe TR. Survival without severe TR was 88.0 ± 1.7% at 10 years. Independent predictors for new severe TR were preoperative moderate TR (HR 2.401; p = 0.008) and atrial fibrillation (AF) (HR 2.119; p = 0.018). At the most recent follow up, furosemide was used in 23.9% patients with and 7.3% patients without new severe TR (p = 0.001). Patients with new severe TR had larger right ventricles and higher pulmonary artery pressures on echocardiography. Among patients with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair, independent predictors for new severe TR were preoperative moderate TR and AF. New severe TR was associated with increased furosemide use.
Acute obstruction by Pannus in patients with aortic medtronic-hall valves: 30 years of experience.
Ellensen, Vegard Skalstad; Andersen, Knut Sverre; Vitale, Nicola; Davidsen, Einar Skulstad; Segadal, Leidulf; Haaverstad, Rune
2013-12-01
Acute dysfunction of mechanical aortic valve prostheses is a life-threatening adverse event. Pannus overgrowth, which is fibroelastic hyperplasia originating from the periannular area, is one cause of dysfunction. The aim of this study was to determine the annual incidence of readmittance resulting from acute obstruction caused by pannus during 30 years of observation in patients with Medtronic-Hall aortic valve prostheses and to analyze the risk factors associated with pannus development. From 1982 to 2004, 1,187 patients in our department underwent aortic valve replacement with Medtronic-Hall mechanical monoleaflet valve prostheses. As of December 31, 2012, 27 of these patients (2.3%) had presented with acute valve dysfunction caused by pannus obstruction. The annual incidence of pannus was 0.7 per 1,000. The median time from the primary operation to prosthetic dysfunction was 11.1 years (range, 1.2 to 26.8 years). Of the 20 patients who underwent reoperation, 2 died. Seven patients died before reoperation. Women had a higher risk for the development of obstructing pannus, and patients with pannus obstruction were younger. Valve size was not an independent risk factor. Women and younger patients are at higher risk for pannus development. When acute dysfunction by pannus is suspected in a mechanical aortic valve, an immediate echocardiogram and an emergency aortic valve replacement should be carried out because of the potential of a fatal outcome. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Olsson, Karin; Nilsson, Johan; Hörnsten, Åsa; Näslund, Ulf
2017-03-01
Aortic stenosis is the most common valve disease in western countries and has poor prognosis without treatment. Surgical aortic valve replacement (SAVR) is the gold standard, and transcatheter aortic valve implantation (TAVI) is a new method that is used in high-risk patients who are denied surgery. The purpose of treatment is not only to save life, but also to reduce symptoms and increase health-related quality of life (HRQoL). The aim of this study was to describe patients' self-reported outcomes in terms of physical function, symptoms, dependence, HRQoL, and cognitive function after TAVI and SAVR. All patients treated with TAVI during 1 year ( n = 24) and age-matched patients treated with SAVR ( n = 24) were included. Data were collected on the day before and at 6 months after treatment using structural questionnaires. Self-rated function was low before treatment and increased at follow-up. A quarter of all patients reported syncope at baseline, and none reported this at follow-up. Breathlessness was reported by all patients to be the most limiting cardiac symptom, but the TAVI patients reported more severe symptoms. At 6 months' follow-up, symptoms were reduced, but breathlessness and fatigue were still common, especially in the TAVI group. HRQoL, which was very low in the TAVI group at baseline, increased in all dimensions except social function. We found no change in cognitive function or dependence at follow-up. There was no difference in the size of improvement between groups. The results could be helpful when informing future patients in order to give them realistic expectations.
Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.
Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A
2008-01-01
The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.
Alfredsson, Joakim; Stebbins, Amanda; Brennan, J Matthew; Matsouaka, Roland; Afilalo, Jonathan; Peterson, Eric D; Vemulapalli, Sreekanth; Rumsfeld, John S; Shahian, David; Mack, Michael J; Alexander, Karen P
2016-04-05
Surgical risk scores do not include frailty assessments (eg, gait speed), which are of particular importance for patients with severe aortic stenosis considering transcatheter aortic valve replacement. We assessed the association of 5-m gait speed with outcomes in a cohort of 8039 patients who underwent transcatheter aortic valve replacement (November 2011-June 2014) and were included in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. We evaluated the association between continuous and categorical gait speed and 30-day all-cause mortality before and after adjustment for Society of Thoracic Surgeons-predicted risk of mortality score and key variables. Secondary outcomes included in-hospital mortality, bleeding, acute kidney injury, and stroke. The overall median gait speed was 0.63 m/s (25th-75th percentile, 0.47-0.79 m/s), with the slowest walkers (<0.5 m/s) constituting 28%, slow walkers (0.5-0.83 m/s) making up 48%, and normal walkers (>0.83 m/s) constituting 24% of the population. Thirty-day all-cause mortality rates were 8.4%, 6.6%, and 5.4% for the slowest, slow, and normal walkers, respectively (P<0.001). Each 0.2-m/s decrease in gait speed corresponded to an 11% increase in 30-day mortality (adjusted odds ratio, 1.11; 95% confidence interval, 1.01-1.22). The slowest walkers had 35% higher 30-day mortality than normal walkers (adjusted odds ratio, 1.35; 95% confidence interval, 1.01-1.80), significantly longer hospital stays, and a lower probability of being discharged to home. Gait speed is independently associated with 30-day mortality after transcatheter aortic valve replacement. Identification of frail patients with the slowest gait speeds facilitates preprocedural evaluation and anticipation of a higher level of postprocedural care. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01737528. © 2016 American Heart Association, Inc.
Rapid Deployment Aortic Replacement (RADAR) Registry in Spain: a protocol.
Bautista-Hernandez, Victor; Cal-Purriños, Natalia; Arribas-Leal, Jose M; Carnero-Alcazar, Manuel; Gutierrez-Diez, Jose F; Cuenca-Castillo, Jose J
2017-01-10
Rapid deployment valves (RDV) represent a newly introduced approach to aortic valve replacement which facilitates surgical implantation and minimally invasive techniques, shortens surgical times and shows excellent haemodynamic performance. However, evidence on their safety, efficacy and potential complications is mostly fitted with small-volume and retrospective studies. Moreover, no current guidelines exist. To improve our knowledge on this technology, The Rapid Deployment Aortic Replacement (RADAR) Registry will be established across Spain with the aim of assessing RDV outcomes in the real-world setting. The RADAR Registry is designed as a product registry that would provide information on its use and outcomes in clinical practice. This multicentre, prospective, national effort will initially involve 4 centres in Spain. Any patient undergoing cardiac surgery for aortic valve replacement and receiving an RDV as an isolated operation or in combination with other cardiac procedures may be included. Participation is voluntary. Data collection is equal to information obtained during standard care and is prospectively entered by the participating physicians perioperatively and during subsequent follow-up visits. The primary outcome assessed is in-hospital and up to 5 years of follow-up, prosthetic valve functioning and clinical status. Secondary outcomes are to perform subgroup analysis, to compare outcomes with other existing approaches and to develop future clinical guidelines. The follow-up assessments are timed with routine clinical appointments. Dissociated data will be extracted and collectively analysed. Initial target sample size for the registry is 500 participants entered with complete follow-up information. Different substudies will be implemented within the registry to investigate specific populations undergoing aortic valve replacement. The protocol is approved by all local institutional ethics committees. Findings will be shared by the participant hospitals, policymakers and the academic community to promote quality monitoring and efficient use of this technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Martin, Jacob A; Mayhew, Christopher R; Morris, Amanda J; Bader, Angela M; Tsai, Mitchell H; Urman, Richard D
2018-04-01
Time-driven activity-based costing (TDABC) is a methodology that calculates the costs of healthcare resources consumed as a patient moves along a care process. Limited data exist on the application of TDABC from the perspective of an anesthesia provider. We describe the use of TDABC, a bottom-up costing strategy and financial outcomes for three different medical-surgical procedures. In each case, a multi-disciplinary team created process maps describing the care delivery cycle for a patient encounter using the TDABC methodology. Each step in a process map delineated an activity required for delivery of patient care. The resources (personnel, equipment and supplies) associated with each step were identified. A per minute cost for each resource expended was generated, known as the capacity cost rate, and multiplied by its time requirement. The total cost for an episode of care was obtained by adding the cost of each individual resource consumed as the patient moved along a clinical pathway. We built process maps for colonoscopy in the gastroenterology suite, calculated costs of an aortic valve replacement by comparing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR) techniques, and determined the cost of carpal tunnel release in an operating room versus an ambulatory procedure room. TDABC is central to the value-based healthcare platform. Application of TDABC provides a framework to identify process improvements for health care delivery. The first case demonstrates cost-savings and improved wait times by shifting some of the colonoscopies scheduled with an anesthesiologist from the main hospital to the ambulatory facility. In the second case, we show that the deployment of an aortic valve via the transcatheter route front loads the costs compared to traditional, surgical replacement. The last case demonstrates significant cost savings to the healthcare system associated with re-organization of staff required to execute a carpal tunnel release.
Mazzeffi, Michael; Kassa, Woderyelesh; Gammie, James; Tanaka, Kenichi; Roman, Philip; Zhan, Min; Griffith, Bartley; Rock, Peter
2015-08-01
Acute respiratory distress syndrome (ARDS) occurs uncommonly after cardiac surgery but has a mortality rate as high as 80%. Aspirin may prevent lung injury in at-risk patients by reducing platelet-neutrophil aggregates in the lung. We hypothesized that preoperative aspirin use would be associated with a decreased risk of ARDS after aortic valve replacement surgery. We performed a retrospective single-center cohort study that included all adult patients who had aortic valve replacement surgery during a 5-year period. The primary outcome variable was postoperative ARDS. The secondary outcome variable was nadir PaO2/FIO2 ratio during the first 72 hours after surgery. Both crude and propensity score-adjusted logistic regression analyses were performed to estimate the odds ratio for developing ARDS in aspirin users. Subgroups were analyzed to determine whether preoperative aspirin use might be associated with improved oxygenation in patients with specific risk factors for lung injury. Of the 375 patients who had aortic valve replacement surgery during the study period, 181 patients took aspirin preoperatively (48.3%) with most taking a dose of 81 mg (72.0%). There were 22 cases of ARDS in the cohort (5.5%). There was no significant difference in the rate of ARDS between aspirin users and nonusers (5.0% vs 6.7%, P = 0.52). There was also no significant difference in the nadir PaO2/FIO2 ratio between aspirin users and nonusers (P = 0.12). The crude odds ratio for ARDS in aspirin users was 0.725 (99% confidence interval, 0.229-2.289; P = 0.47), and the propensity score-adjusted odds ratio was 0.457 (99% confidence interval, 0.120-1.730; P = 0.13). Within the constraints of this analysis that included only 22 affected patients, preoperative aspirin use was not associated with a decreased incidence of ARDS after aortic valve replacement surgery or improved oxygenation.
Aortic root surgery in the United States: a report from the Society of Thoracic Surgeons database.
Stamou, Sotiris C; Williams, Mathew L; Gunn, Tyler M; Hagberg, Robert C; Lobdell, Kevin W; Kouchoukos, Nicholas T
2015-01-01
The purpose of the present study was to evaluate the early clinical outcomes of aortic root surgery in the United States. The Society of Thoracic Surgeons database was queried to identify all patients who had undergone aortic root replacement from 2004 to early 2010 (n = 13,743). The median age was 58 years (range, 18-96); 3961 were women (29%) and 12,059 were white (88%). The different procedures included placement of a mechanical valve conduit (n = 4718, 34%), stented pericardial (n = 879, 6.4%) or porcine (n = 478, 3.5%) bioprosthesis, stentless root (n = 4309, 31%), homograft (n = 498, 3.6%), and valve sparing root replacement (n = 1918, 14%). The median number of aortic root surgeries per site was 2, and only 5% of sites performed >16 aortic root surgeries annually. An increased trend to use biostented (porcine or pericardial) valves during the study period (7% in 2004 vs 14% in 2009). The operative (raw) mortality was greater among the patients with aortic stenosis (6.2%) who had undergone aortic root replacement, independent of age. Mortality was greater in patients who had undergone concomitant valve or coronary artery bypass grafting or valve surgery (21%). The lowest operative mortality was observed in patients who had undergone aortic valve sparing procedures (1.9%). Most cardiac centers performed aortic root surgery in small volumes. The unadjusted operative mortality was greater for patients >80 years old and those with aortic stenosis, regardless of age. Valve sparing root surgery was associated with the lowest mortality. A trend was seen toward an increased use of stented tissue valves from 2004 to 2009. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Myectomy and LA-to-LV Conduit for Severe Calcific Mitral Stenosis and Hypertrophic Cardiomyopathy.
Meghji, Zahara; Nguyen, Anita; Geske, Jeffrey B; Schaff, Hartzell V
2018-02-26
Severe calcific mitral valve stenosis can rarely occur concomitantly with obstructive hypertrophic cardiomyopathy. In these patients, surgical decalcification of the stenotic mitral valve followed by mitral valve replacement carries significant operative risk and may result in paravalvular leakage, atrioventricular groove disruption, and excessive bleeding. We report the first 2 cases of obstructive hypertrophic cardiomyopathy with severe calcific mitral valve stenosis successfully treated with concomitant transaortic septal myectomy and bypass of the stenotic mitral valve using a valved left atrium to left ventricular conduit. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
How to Make a Heart Valve: From Embryonic Development to Bioengineering of Living Valve Substitutes
MacGrogan, Donal; Luxán, Guillermo; Driessen-Mol, Anita; Bouten, Carlijn; Baaijens, Frank; de la Pompa, José Luis
2014-01-01
Cardiac valve disease is a significant cause of ill health and death worldwide, and valve replacement remains one of the most common cardiac interventions in high-income economies. Despite major advances in surgical treatment, long-term therapy remains inadequate because none of the current valve substitutes have the potential for remodeling, regeneration, and growth of native structures. Valve development is coordinated by a complex interplay of signaling pathways and environmental cues that cause disease when perturbed. Cardiac valves develop from endocardial cushions that become populated by valve precursor mesenchyme formed by an epithelial–mesenchymal transition (EMT). The mesenchymal precursors, subsequently, undergo directed growth, characterized by cellular compartmentalization and layering of a structured extracellular matrix (ECM). Knowledge gained from research into the development of cardiac valves is driving exploration into valve biomechanics and tissue engineering directed at creating novel valve substitutes endowed with native form and function. PMID:25368013
1986-09-01
source of the module/system. Source options are; battery, gas, cartridge, valve , and miscellaneous costs. NAMELIST OPERAT is used to compile the...hardware costs allocated to transportation for packing. TF1 = Initial transportation factor. WEIGHT = Shipping weight of total system. XSUM = System float...CD(6,I)+CD(9,I). . AROC(7,I) - Replenishment spares by year. CD(4,I) - Valve replacement cost by year. CD(5,I) = Cartridge replacement cost by year
Outcomes of Solo Smart valve in a single-center experience of 270 patients.
Liu, Hao; Khani-Hanjani, Abbas; Yang, Siyuan; Wang, Wei; Sidhu, Surita; Mullen, John; Modry, Dennis; Wang, Shaohua
2018-04-03
The Solo Smart pericardial aortic valve has been widely used in Europe as an option for aortic valve replacement (AVR). We are reporting early and midterm clinical outcomes of AVR with the Solo Smart valve in a single North America center. This is a retrospective study of 270 consecutive patients who had AVR at Mazankowski Alberta Heart Institute from February 2011 to March 2015. Follow-up and echocardiographic data were collected retrospectively from electronic and paper charts. Univariate and multivariate analysis were performed to evaluate the results. The mean age was 71.2±10.0 years, 67.4% were male, and 79.3% had combined procedures. Mean STS Score was 4.18±3.91. Early mortality was 3.7% for the entire group and 0% for isolated aortic valve replacement group. Mean cross-clamp time for isolated AVR and AVR with concomitant procedure was 70.8±12.7min and 117.0±45.0min, respectively. Permanent pacemaker implantation was necessary in 2.2% of patients. Echocardiography demonstrated a reduction in mean gradients from 40.8±17.4mmHg to 7.6±3.7 mmHg and peak gradient from 72.5 ± 48.8 mmHg to 15.5±7.5 mmHg. The 1-, 3-, and 5- year overall survival was 93.0%, 86.5% and 75.9%, respectively. At 5 years, freedom from valve-related death was 92.4%, freedom from structural valve deterioration and freedom from aortic valve reoperation were 96.4% and 98%, respectively. The Solo Smart valve is safe and has excellent hemodynamic performance. Aortic valve reoperation and rates of valve-related adverse events during midterm follow-up were low.
South, Harry L; Osoro, Moses; Overly, Tjuan
2014-01-01
We report a 73-year-old male with late onset monomorphic ventricular tachycardia following mitral valve repair (MVR). Typically, injury to epicardial arteries following mitral valve repair/replacement presents immediately as ventricular tachycardia/fibrillation, difficulty weaning from cardiopulmonary bypass, worsening ECG changes, increasing cardiac biomarkers, or new wall motion abnormalities. Our case illustrates a "late complication" of a distorted circumflex artery following mitral valve repair and the importance of early diagnostic angiography and percutaneous intervention.
Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator
NASA Technical Reports Server (NTRS)
Ramspacher, Daniel J. (Inventor); Richard, James A. (Inventor)
2017-01-01
A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.
Percutaneous re-revalvulation of the tricuspid valve.
Gewillig, Marc; Dubois, Christophe
2011-04-01
We report a successful percutaneous revalvulation of a dysfunctional tricuspid bioprothesis in an 8-year-old child. Five years after implanting a 25-mm Carpentier-Edwards valve in the tricuspid position, the prosthesis showed significant dysfunction with clinical right heart failure. A 26-mm Edwards-Sapien XT inverted aortic valve was successfully implanted through a 19F sheath using a jugular approach. Such procedure can significantly postpone the need for surgical replacement of a biological valve. Copyright © 2011 Wiley-Liss, Inc.
Kalantre, Atul; Vettukattil, Joseph; Haw, Marcus; Veldtman, Gruschen R
2007-12-01
Paravalvular leaks are a recognized complication of valve replacement surgery. We report a 47-year-old man with left atrial isomerism, interrupted left sided inferior caval vein with unilateral left sided superior caval vein, a common atrium, and anomalous pulmonary venous connection to the coronary sinus, who had recurrent severe para-right atrioventricular (AV) regurgitation with gross right heart failure following tricuspid valve (TCV) replacement. He underwent a hybrid surgery-transcatheter treatment strategy in the cardiac catheterization laboratory, which led to significant improvement in hemodynamics and symptoms. This to our knowledge is the first reported case of a minimally invasive approach to para-right sided AV valve regurgitation.
Kapoor, Aditya; Syal, Sanjiv; Gupta, Nirmal; Gupta, Archana
2011-07-01
The use of temporary epicardial pacing wires during cardiac surgery is a routine procedure and has been associated with low morbidity. We describe a rare case of right paracardiac mass due to organized pericardial hematoma with right atrial compression around the epicardial pacing wires left in-situ, presenting three months following aortic valve replacement surgery. The case highlights the fact that such delayed complications can rarely occur around retained epicardial pacing wires following open heart surgery especially in patients on oral anticoagulants. The clinician should be alert to such an occurrence and during follow-up echocardiography always pay attention not only to the valve and ventricular function, but also to the pericardial and extra-pericardial space.
Breath-hold device for laboratory rodents undergoing imaging procedures.
Rivera, Belinda; Bushman, Mark J; Beaver, Richard G; Cody, Dianna D; Price, Roger E
2006-07-01
The increased use in noninvasive imaging of laboratory rodents has prompted innovative techniques in animal handling. Lung imaging of rodents can be a difficult task because of tissue motion caused by breathing, which affects image quality. The use of a prototype flat-panel computed tomography unit allows the acquisition of images in as little as 2, 4, or 8 s. This short acquisition time has allowed us to improve the image quality of this instrument by performing a breath-hold during image acquisition. We designed an inexpensive and safe method for performing a constant-pressure breath-hold in intubated rodents. Initially a prototypic manual 3-way valve system, consisting of a 3-way valve, an air pressure regulator, and a manometer, was used to manually toggle between the ventilator and the constant-pressure breath-hold equipment. The success of the manual 3-way valve system prompted the design of an electronically actuated valve system. In the electronic system, the manual 3-way valve was replaced with a custom designed 3-way valve operated by an electrical solenoid. The electrical solenoid is triggered by using a hand-held push button or a foot pedal that is several feet away from the gantry of the scanner. This system has provided improved image quality and is safe for the animals, easy to use, and reliable.
The perceval S aortic valve implantation in patients with porcelain aorta; is this ideal option?
Baikoussis, Nikolaos G; Dedeilias, Panagiotis; Prappa, Efstathia; Argiriou, Michalis
2017-01-01
We would like to present in this paper a patient with severe aortic valve stenosis referred to our department for surgical aortic valve replacement. In this patient, it was intraoperatively detected an unexpected heavily calcified porcelain ascending aorta. We present the treatment options in this situation, the difficulties affronted intraoperatively, the significance of the preoperative chest computed tomography scan and the use of the Perceval S aortic valve as ideal bioprosthesis implantation. This is a self-expanding, self-anchoring, and sutureless valve with a wide indication in all patients requiring aortic bioprosthesis.
NASA Technical Reports Server (NTRS)
Yungster, Shaye; Paxson, Daniel E.; Perkins, Hugh D.
2016-01-01
A computational investigation of a pressure-gain combustor system for gas turbine applications is presented. The system consists of a valved pulse combustor and an ejector, housed within a shroud. The study focuses on two enhancements to previous models, related to the valve and ejector components. First, a new poppet inlet valve system is investigated, replacing the previously used reed valve configuration. Secondly, a new computational approach to approximating the effects of choked turbine inlet guide vanes present immediately downstream of the Ejector-Enhanced Resonant Pulse Combustor (EERPC) is investigated. Instead of specifying a back pressure at the EERPC exit boundary (as was done in previous studies) the new model adds a converging-diverging (CD) nozzle at the exit of the EERPC. The throat area of the CD nozzle can be adjusted to obtain the desired back pressure level and total mass flow rate. The results presented indicate that the new poppet valve configuration performs nearly as well as the original reed valve system, and that the addition of the CD nozzle is an effective method to approximate the exit boundary effects of a turbine present downstream of the EERPC. Furthermore, it is shown that the more acoustically reflective boundary imposed by a nozzle as compared to a constant pressure surface does not significantly affect operation or performance.
A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves.
Sotiropoulos, Fotis; Borazjani, Iman
2009-03-01
In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid-structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment.
A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves
Borazjani, Iman
2009-01-01
In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid–structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment. PMID:19194734
NASA Astrophysics Data System (ADS)
Hatt, Charles R.; Wagner, Martin; Raval, Amish N.; Speidel, Michael A.
2016-03-01
Transcatheter aortic valve replacement (TAVR) requires navigation and deployment of a prosthetic valve within the aortic annulus under fluoroscopic guidance. To support improved device visualization in this procedure, this study investigates the feasibility of frame-by-frame 3D reconstruction of a moving and expanding prosthetic valve structure from simultaneous bi-plane x-ray views. In the proposed method, a dynamic 3D model of the valve is used in a 2D/3D registration framework to obtain a reconstruction of the valve. For each frame, valve model parameters describing position, orientation, expansion state, and deformation are iteratively adjusted until forward projections of the model match both bi-plane views. Simulated bi-plane imaging of a valve at different signal-difference-to-noise ratio (SDNR) levels was performed to test the approach. 20 image sequences with 50 frames of valve deployment were simulated at each SDNR. The simulation achieved a target registration error (TRE) of the estimated valve model of 0.93 +/- 2.6 mm (mean +/- S.D.) for the lowest SDNR of 2. For higher SDNRs (5 to 50) a TRE of 0.04 mm +/- 0.23 mm was achieved. A tabletop phantom study was then conducted using a TAVR valve. The dynamic 3D model was constructed from high resolution CT scans and a simple expansion model. TRE was 1.22 +/- 0.35 mm for expansion states varying from undeployed to fully deployed, and for moderate amounts of inter-frame motion. Results indicate that it is feasible to use bi-plane imaging to recover the 3D structure of deformable catheter devices.
Hatt, Charles R; Wagner, Martin; Raval, Amish N; Speidel, Michael A
2016-01-01
Transcatheter aortic valve replacement (TAVR) requires navigation and deployment of a prosthetic valve within the aortic annulus under fluoroscopic guidance. To support improved device visualization in this procedure, this study investigates the feasibility of frame-by-frame 3D reconstruction of a moving and expanding prosthetic valve structure from simultaneous bi-plane x-ray views. In the proposed method, a dynamic 3D model of the valve is used in a 2D/3D registration framework to obtain a reconstruction of the valve. For each frame, valve model parameters describing position, orientation, expansion state, and deformation are iteratively adjusted until forward projections of the model match both bi-plane views. Simulated bi-plane imaging of a valve at different signal-difference-to-noise ratio (SDNR) levels was performed to test the approach. 20 image sequences with 50 frames of valve deployment were simulated at each SDNR. The simulation achieved a target registration error (TRE) of the estimated valve model of 0.93 ± 2.6 mm (mean ± S.D.) for the lowest SDNR of 2. For higher SDNRs (5 to 50) a TRE of 0.04 mm ± 0.23 mm was achieved. A tabletop phantom study was then conducted using a TAVR valve. The dynamic 3D model was constructed from high resolution CT scans and a simple expansion model. TRE was 1.22 ± 0.35 mm for expansion states varying from undeployed to fully deployed, and for moderate amounts of inter-frame motion. Results indicate that it is feasible to use bi-plane imaging to recover the 3D structure of deformable catheter devices.
García-Bengochea, José; Sierra, Juan; González-Juanatey, José R; Rubio, José; Vega, Marino; Fernández, Angel L; Sánchez, Daniel
2006-05-01
The study aim was to evaluate the durability of the new Mitroflow 12A pericardial bioprosthesis and to assess ventricular mass regression after aortic valve replacement (AVR) in patients with small valves. A total of 326 Mitroflow 12A pericardial bioprostheses was implanted without any other associated valve procedure. The mean patient age was 73.5 +/- 6.1 years; 252 patients (78.0%) were in NYHA class III/IV. Small valves (19 and 21 mm) were implanted in 212 patients (65.6%). The total follow up period was 837.1 patient-years (pt-yr). A subset of 61 patients with preoperative stenosis was selected and submitted to conventional echo-Doppler assessment at a mean period of 11.1 months after surgery. Hospital mortality was 8.6%. At eight years of follow up, survival was 57.1%. Freedom from structural valve deterioration (SVD) was 86.5% per pt-yr. Mean gradients were significantly reduced postoperatively for each valve size (to 18 +/- 8 mmHg for 19-mm valves and 12 +/- 4 mmHg for 25-mm valves). The effective orifice area (EOA) was also increased significantly for all valve sizes (to 1.1 +/- 0.1 cm2 for 19-mm valves and 1.8 +/- 0.2 cm2 for 25-mm valves). The left ventricular mass index (LVMI) decreased significantly, from 177 +/- 29 to 136 +/- 22 g/m2 for the 19-mm valve, and from 200 +/- 42 to 132 +/- 22 g/m2 for the 25-mm valve. The EOA index (EOAI) showed mismatch for the 19- and 21-mm valves (0.74 and 0.82 cm2/m2, respectively). The diagrammatic calculation between LVMI and relative wall thickness after surgery showed that 29.7% of patients achieved a normal pattern of remodeling (including 19- and 21-mm valves), despite various degrees of mismatch. The new Mitroflow 12A pericardial bioprosthesis showed an absence of mechanical failure after an eight-year follow up, with a satisfactory rate of SVD. Significant reductions in LVMI and improved ventricular geometry were observed, despite the small valve sizes implanted.
Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.
Mohammadi, Siamak; Baillot, Richard; Voisine, Pierre; Mathieu, Patrick; Dagenais, François
2006-08-01
Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical presentation of structural valve deterioration in the Freestyle stentless bioprosthesis. Between January 1993 and August 2005, 608 patients underwent aortic valve replacement with a Freestyle stentless bioprosthesis. The implantation technique was subcoronary in 475 patients and a root replacement in 133 patients. Mean overall follow-up was 5.6 +/- 3.4 years. Follow-up was complete in all patients. Clinical and echocardiographic follow-ups were conducted prospectively. Freedom from structural valve deterioration was 95.8% at 10 years. Twelve patients showed evidence of structural valve deterioration and underwent reoperation for aortic regurgitation (n = 10) or aortic stenosis (n = 2). The mean age of patients with structural valve deterioration was significantly lower than patients without structural valve deterioration (62.6 +/- 8.2 years vs 68.6 +/- 8.3 years, P = .02). The median time between implantation and explantation was 8.7 years (range: 1.9-13.3 years). Eleven structural valve deteriorations occurred after subcoronary implantation, and 1 structural valve deterioration occurred after root implantation (P = .4). The mechanisms of structural valve deterioration were leaflet tears in 10 patients (6 in the left coronary cusp and 4 in the right coronary cusp), severe valve calcification in 1 patient, and cusp fibrosis in 1 patient. The interval between onset of symptoms and reoperation was acute or subacute in 10 patients. At 10 years, the Freestyle stentless bioprosthesis shows excellent freedom from structural valve deterioration. Structural valve deterioration in the Freestyle stentless bioprosthesis relates to leaflet tear with minimal calcification in the majority of cases. Because of the fast onset of symptoms with leaflet tear, patients with a Freestyle stentless bioprosthesis should be informed of the preferential mode of failure and time-frame of symptoms.
Hurwitz, Seth Eric; Waxman, Daniel; Hecht, Susan
2009-09-01
Pannus formation and valve thrombus can cause prosthetic valve failure. The authors report the case of a 50-year-old woman who presented to the emergency room with decompensated heart failure secondary to mechanical valve dysfunction. On two-dimensional and transesophageal echocardiography, the patient had severe aortic stenosis and regurgitation. A thrombus seen on the valve was felt to be the etiology of her prosthetic valve failure. She underwent emergent cardiac surgery for aortic valve replacement. Pathology revealed that although a small thrombus was present, extensive pannus was the underlying mechanism of valve dysfunction. Differentiation between pannus and thrombus may have important clinical implications, but this case illustrates that distinguishing between these entities by echocardiographic and clinical criteria may not be possible.
The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement
McElhinney, Doff B; Hennesen, Jill T
2013-01-01
The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411
Isais, Florante Santos; Lee, Cheng Chuan
2013-01-01
Cardiobacterium valvarum is a relatively novel agent of infective endocarditis. We describe the first case of infective endocarditis due to this pathogen in the Asian Pacific. This case is unique in its involvement of the mitral valve as well as its clinical resolution exclusively resulting from treatment with antibiotics without resorting to valve replacement/explantation. PMID:23576538
Khalique, Omar K; Pulerwitz, Todd C; Halliburton, Sandra S; Kodali, Susheel K; Hahn, Rebecca T; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Leon, Martin B; D'Souza, Belinda; Einstein, Andrew J
2016-01-01
Transcatheter aortic valve replacement (TAVR) is performed frequently in patients with severe, symptomatic aortic stenosis who are at high risk or inoperable for open surgical aortic valve replacement. Computed tomography angiography (CTA) has become the gold standard imaging modality for pre-TAVR cardiac anatomic and vascular access assessment. Traditionally, cardiac CTA has been most frequently used for assessment of coronary artery stenosis, and scanning protocols have generally been tailored for this purpose. Pre-TAVR CTA has different goals than coronary CTA and the high prevalence of chronic kidney disease in the TAVR patient population creates a particular need to optimize protocols for a reduction in iodinated contrast volume. This document reviews details which allow the physician to tailor CTA examinations to maximize image quality and minimize harm, while factoring in multiple patient and scanner variables which must be considered in customizing a pre-TAVR protocol. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Application of Hydrogels in Heart Valve Tissue Engineering
Zhang, Xing; Xu, Bin; Puperi, Daniel S.; Wu, Yan; West, Jennifer L.; Grande-Allen, K. Jane
2015-01-01
With an increasing number of patients requiring valve replacement, there is heightened interest in advancing heart valve tissue engineering (HVTE) to provide solutions to the many limitations of current surgical treatments. A variety of materials have been developed as scaffolds for HVTE including natural polymers, synthetic polymers, and decellularized valvular matrices. Among them, biocompatible hydrogels are generating growing interest. Natural hydrogels, such as collagen and fibrin, generally show good bioactivity, but poor mechanical durability. Synthetic hydrogels, on the other hand, have tunable mechanical properties; however, appropriate cell-matrix interactions are difficult to obtain. Moreover, hydrogels can be used as cell carriers when the cellular component is seeded into the polymer meshes or decellularized valve scaffolds. In this review, we discuss current research strategies for HVTE with an emphasis on hydrogel applications. The physicochemical properties and fabrication methods of these hydrogels, as well as their mechanical properties and bioactivities are described. Performance of some hydrogels including in vitro evaluation using bioreactors and in vivo tests in different animal models are also discussed. For future HVTE, it will be compelling to examine how hydrogels can be constructed from composite materials to replicate mechanical properties and mimic biological functions of the native heart valve. PMID:25955010
Pulerwitz, Todd C.; Khalique, Omar K.; Nazif, Tamim N.; Rozenshtein, Anna; Pearson, Gregory D.N.; Hahn, Rebecca T.; Vahl, Torsten P.; Kodali, Susheel K.; George, Isaac; Leon, Martin B.; D'Souza, Belinda; Po, Ming Jack; Einstein, Andrew J.
2016-01-01
Background Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable. Methods 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30mL/min) who underwent a novel VLCV protocol (20mL of iohexol at 2.5mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale. Results VLCV patients had mean(±SD) age 86±6.5, BMI 23.9±3.4 kg/m2 with 54% men; SCV patients age 83±8.8, BMI 28.7±5.3 kg/m2, 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement. Conclusions This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment. PMID:27061253
2014-01-01
Background Mechanical heart valve replacement has an inherent risk of thromboembolic events (TEs). Current guidelines recommend an international normalized ratio (INR) of at least 2.5 after mechanical mitral valve replacement (MVR). This study aimed to evaluate the effects of a low INR (2.0–2.5) on thromboembolic and bleeding complications in patients with mechanical MVR on warfarin therapy. Methods One hundred and thirty-five patients who underwent mechanical MVR were enrolled in this study. The end points of this study were defined as TEs (valve thrombosis, transient ischemic attack, stroke) and bleeding (all minor and major bleeding) complications. Patients were followed up for a mean of 39.6 months and the mean INR of the patients was calculated. After data collection, patients were divided into 3 groups according to their mean INR, as follows: group 1 (n = 34), INR <2.0; group 2 (n = 49), INR 2.0–2.5; and group 3 (n = 52), INR >2.5. Results A total of 22 events (10 [7.4%] thromboembolic and 12 [8.8%] bleeding events) occurred in the follow-up period. The mean INR was an independent risk factor for the development of TEs. Mean INR and neurological dysfunction were independent risk factors for the development of bleeding events. A statistically significant positive correlation was found between the log mean INR and all bleeding events, and a negative correlation was found between the log mean INR and all TEs. The total number of events was significantly lower in group 2 than in groups 1 and 3 (P = 0.036). Conclusions This study showed that a target INRs of 2.0–2.5 are acceptable for preventing TEs and safe in terms of bleeding complications in patients with mechanical MVR. PMID:24885719
Wang, Jian-tang; Dong, Ming-feng; Song, Guang-min; Ma, Zeng-shan; Ma, Sheng-jun
2014-12-01
The safety and efficacy of combined low dose aspirin and warfarin therapy in patients with atrial fibrillation after mechanical heart valve replacement were evaluated. A total of 1016 patients (620 females, mean age of 36.8±7.7 years) admitted for cardiac valve replacement and complicated with atrial fibrillation after surgery were randomly divided into study (warfarin plus 75-100 mg aspirin) or control (warfarin only) groups. International normalized ratio (INR) and prothrombin time were maintained at 1.8-2.5 and 1.5-2.0 times the normal values, respectively. Thromboembolic events and major bleedings were registered during the follow-up period. Patients were followed up for 24±9 months. The average dose of warfarin in the study and control groups was 2.91±0.83 mg and 2.88±0.76 mg, respectively (P>0.05). The incidence of overall thromboembolic events in study group was lower than that in control group (2.16% vs. 4.35%, P=0.049). No statistically significant differences were found in hemorrhage events (3.53% vs. 3.95%, P=0.722) or mortality (0.20% vs. 0.40%, P=0.559) between the two groups. Combined low dose aspirin and warfarin therapy in the patients with atrial fibrillation following mechanical heart valve replacement significantly decreased thromboembolic events as compared with warfarin therapy alone. This combined treatment was not associated with an increase in the risk of major bleeding or mortality.
Reoperation for composite valve graft failure: Operative results and midterm survival.
Maroto, Luis C; Carnero, Manuel; Cobiella, Javier; García, Mónica; Vilacosta, Isidre; Reguillo, Fernando; Villagrán, Enrique; Olmos, Carmen
2018-06-01
The replacement of a failed composite valve graft is technically more demanding and is associated with increased morbidity and mortality. We present our technique and outcomes for reoperations for composite graft failures. Between September 2011 and June 2017, 14 patients underwent a redo composite graft replacement. Twelve patients (85.7%) were male, and mean age was 58.4 years ± 12 standard deviation (SD). One patient had two previous root replacements. Indications for reoperation were endocarditis (8), aortic pseudoaneurysm (3), and aortic prosthesis thrombosis (3). Mean logistic EuroSCORE and EuroSCORE II were 30.8% and 14.7%, respectively. A mechanical composite graft was used in 12 patients and biological composite grafts were used in two patients. Hospital mortality was 14.3% (n = 2). One patient (7.1%) required reoperation for bleeding, One patient (7.1%) had mechanical ventilation >24 h, and four patients (28.6%) required implantation of a permanent pacemaker. Median intensive care unit and hospital stays were 3 days (interquartile range [IQR] 1-5) and 10 days (IQR 6.5-38.5). One patient experienced recurrent prosthetic valve endocarditis 14 months after operation. On follow-up, 11 of 12 survivors were in New York Heart Association class I or II. Survival at 3 years was 85.7% ± 9.4% SD. Composite valve graft replacement can be performed with acceptable morbidity and mortality with good mid-term survival. © 2018 Wiley Periodicals, Inc.
Methods and compositions for rapid thermal cycling
Beer, Neil Reginald; Benett, William J.; Frank, James M.; Deotte, Joshua R.; Spadaccini, Christopher
2015-10-27
The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.
Methods and compositions for rapid thermal cycling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beer, Neil Reginald; Benett, William J.; Frank, James M.
The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature ofmore » the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.« less
Textile for heart valve prostheses: fabric long-term durability testing.
Heim, Frederic; Durand, Bernard; Chakfe, Nabil
2010-01-01
The rapid developments and success in percutaneous vascular surgery over the last two decades with the now common stent grafts implantation, make the noninvasive surgery technique today attractive even for heart valve replacement. Less traumatic for the patient and also less time consuming, percutaneous heart valve replacement is however at its beginning and restricted to end of life patients. The noninvasive procedure expects from the heart valve prosthesis material to be resistant and adapted to folding requirements of the implantation process (catheter). Polyester fabric could be a suited material for heart valve implanted percutaneously. Highly flexible and resistant, polyester fabric proved to be well adapted to the dynamic behavior of a valve and polyester (Dacron) is also widely used for vascular grafts implantation and shows good biocompatibility and durability. However, today there's no data available on long-term durability of fabric used as heart valve material. The purpose of this work is to study the long term behavior of a microdenier polyester fabric construction under combined in vitro flexure and tension fatigue stress. In the novel in vitro testing technique presented, a fabric specimen was subjected to combined flexural and tensile fatigue generated by fluid flow under physiological pressure conditions. The results obtained show how flexural properties change with fatigue time, which reflects directly on the suitability of a fabric in such devices. It was also observed that these fabric structural changes directly influence the in vitro behavior of the textile heart valve prosthesis. (c) 2009 Wiley Periodicals, Inc.
Bozkurt, Engin; Keleş, Telat; Durmaz, Tahir; Akçay, Murat; Ayhan, Hüseyin; Bayram, Nihal Akar; Aslan, Abdullah Nabi; Baştuğ, Serdal; Bilen, Emine
2014-01-01
Introduction Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. Aim Description early results of our single-center experience with balloon expandable aortic valve implantation. Material and methods Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. Results The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004). Conclusions We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an effective and relatively safe procedure for the treatment of severe aortic stenosis in suitable patients. PMID:25061453
El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A
2018-01-23
Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.
Fibrinolytic therapy for mechanical pulmonary valve thrombosis.
Khajali, Zahra; Mohammadzadeh, Shabnam; Maleki, Majid; Peighambari, Mohammad Mehdi; Sadeghpoor, Anita; Ghavidel, Alireza; Elahi, Behrad; Mirzaaghayan, Mohammadreza
2015-01-01
Treatment of prosthetic heart valve thrombosis using intravenous thrombolytics, although an acceptable alternative to surgery, is not complication free, and the literature has a dearth of data on the subject. This study analyzed the results of fibrinolytic treatment (FT) among a single-center group of patients with mechanical pulmonary valve thrombosis. Between 2000 and 2013, 23 consecutive patients with 25 episodes of pulmonary valve thrombosis received FT. The diagnosis of mechanical pulmonary valve thrombosis was established by fluoroscopy and echocardiography. Streptokinase (SK) was used in 24 cases and alteplase in 1 case. The FT was continued a second day for 14 patients (58.3%), a third day for 1 patient, and a fourth day for 1 patient. Echocardiography and fluoroscopy were performed every day until improvement of malfunction was achieved. Of the 23 patients, 19 had complete resolution of hemodynamic abnormalities after FT, 1 had partial resolution, and 2 showed no change. No patient had major complications. Five minor complications were detected, namely, fever, nausea, thrombophlebitis, epistaxi, and pain. Seven patients (30%) experienced recurrence of thrombosis, whereas four patients had surgery (biological pulmonary valve replacement) without re-thrombolytic therapy, one patient was treated with Alteplase, one patient received SK, and one patient received intense anticoagulation using heparin and warfarin. Overall, FT had a success rate of 84%. The results indicate that regardless of the time to pulmonary valve replacement and echocardiographic and fluoroscopic findings, FT was effective in most cases of mechanical pulmonary valve thrombosis. The efficacy increased with second-day thrombolytic therapy. Major complications were not common after lytic therapy for mechanical pulmonary valve thrombosis.
Mitral-valve repair versus replacement for severe ischemic mitral regurgitation.
Acker, Michael A; Parides, Michael K; Perrault, Louis P; Moskowitz, Alan J; Gelijns, Annetine C; Voisine, Pierre; Smith, Peter K; Hung, Judy W; Blackstone, Eugene H; Puskas, John D; Argenziano, Michael; Gammie, James S; Mack, Michael; Ascheim, Deborah D; Bagiella, Emilia; Moquete, Ellen G; Ferguson, T Bruce; Horvath, Keith A; Geller, Nancy L; Miller, Marissa A; Woo, Y Joseph; D'Alessandro, David A; Ailawadi, Gorav; Dagenais, Francois; Gardner, Timothy J; O'Gara, Patrick T; Michler, Robert E; Kron, Irving L
2014-01-02
Ischemic mitral regurgitation is associated with a substantial risk of death. Practice guidelines recommend surgery for patients with a severe form of this condition but acknowledge that the supporting evidence for repair or replacement is limited. We randomly assigned 251 patients with severe ischemic mitral regurgitation to undergo either mitral-valve repair or chordal-sparing replacement in order to evaluate efficacy and safety. The primary end point was the left ventricular end-systolic volume index (LVESVI) at 12 months, as assessed with the use of a Wilcoxon rank-sum test in which deaths were categorized below the lowest LVESVI rank. At 12 months, the mean LVESVI among surviving patients was 54.6±25.0 ml per square meter of body-surface area in the repair group and 60.7±31.5 ml per square meter in the replacement group (mean change from baseline, -6.6 and -6.8 ml per square meter, respectively). The rate of death was 14.3% in the repair group and 17.6% in the replacement group (hazard ratio with repair, 0.79; 95% confidence interval, 0.42 to 1.47; P=0.45 by the log-rank test). There was no significant between-group difference in LVESVI after adjustment for death (z score, 1.33; P=0.18). The rate of moderate or severe recurrence of mitral regurgitation at 12 months was higher in the repair group than in the replacement group (32.6% vs. 2.3%, P<0.001). There were no significant between-group differences in the rate of a composite of major adverse cardiac or cerebrovascular events, in functional status, or in quality of life at 12 months. We observed no significant difference in left ventricular reverse remodeling or survival at 12 months between patients who underwent mitral-valve repair and those who underwent mitral-valve replacement. Replacement provided a more durable correction of mitral regurgitation, but there was no significant between-group difference in clinical outcomes. (Funded by the National Institutes of Health and the Canadian Institutes of Health; ClinicalTrials.gov number, NCT00807040.).
Hamatani, Yasuhiro; Ishibashi-Ueda, Hatsue; Nagai, Toshiyuki; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Fujita, Tomoyuki; Kobayashi, Junjiro; Anzai, Toshihisa
2016-01-01
Background Congenital bicuspid aortic valve (CBAV) is the main cause of aortic stenosis (AS) in young adults. However, the histopathological features of AS in patients with CBAV have not been fully investigated. Methods and Results We examined specimens of aortic valve leaflets obtained from patients who had undergone aortic valve re/placement at our institution for severe AS with CBAV (n = 24, CBAV-AS group), severe AS with tricuspid aortic valve (n = 24, TAV-AS group), and severe aortic regurgitation (AR) with CBAV (n = 24, CBAV-AR group). We compared the histopathological features among the three groups. Pathological features were classified using semi-quantitative methods (graded on a scale 0 to 3) by experienced pathologists without knowledge of the patients’ backgrounds. The severity of inflammation, neovascularization, and calcium and cholesterol deposition did not differ between the CBAV-AS and TAV-AS groups, and these four parameters were less marked in the CBAV-AR group than in the CBAV-AS (all p<0.01). Meanwhile, the grade of valvular fibrosis was greater in the CBAV-AS group, compared with the TAV-AS and CBAV-AR groups (both p<0.01). In AS patients, thickness of fibrotic lesions was greater on the aortic side than on the ventricular side (both p<0.01). Meanwhile, thickness of fibrotic lesions was comparable between the aortic and ventricular sides in CBAV-AR patients (p = 0.35). Conclusions Valvular fibrosis, especially on the aortic side, was greater in patients with CBAV-AS than in those without, suggesting a difference in the pathogenesis of AS between CBAV and TAV. PMID:27479126
Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.
Scott, S M; Sethi, G K; Paulson, D M; Takaro, T
1978-04-01
Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.
Mechanical valve obstruction: Review of diagnostic and treatment strategies
Salamon, Jason; Munoz-Mendoza, Jerson; Liebelt, Jared J; Taub, Cynthia C
2015-01-01
Prosthetic valve obstruction (PVO) is a rare but feared complication of mechanical valve replacement. Diagnostic evaluation should focus on differentiating prosthetic valve thrombosis (PVT) from pannus formation, as their treatment options differ. History of sub-optimal anti-coagulation and post-op time course to development of PVO are useful clinical characteristics in differentiating thrombus from pannus formation. Treatment of PVT is influenced by the patient’s symptoms, valve location, degree of obstruction and thrombus size and may include thrombolysis or surgical intervention. Alternatively, pannus formation requires surgical intervention. The purpose of this article is to review the pathophysiology, epidemiology, diagnostic approach and treatment options for aortic and mitral valve PVO. PMID:26730292
The Ross operation: the autologous pulmonary valve in the aortic position.
Gonzalez-Lavin, L; Robles, A; Graf, D
1988-03-01
Aortic valve replacement (AVR) with a pulmonary valve autograft (PVA) was first reported by Donald N. Ross (DNR) in 1967. The expectation of this procedure was to avoid degenerative changes seen in other biological tissue valves such as calcification, attenuation, and rupture of the leaflets. Recent reports by the original investigator's group have confirmed the lack of degenerative changes in PVA. To corroborate their conclusions, the fate of 12 patients undergoing AVR with PVA by one of us (LGL) has been ascertained. From March 1969 to June 1971, 12 patients underwent AVR with PVA. The right ventricular outflow tract (RVOT) was reconstructed with an aortic homograft valved conduit. The mean age was 42.7 years (range 21 to 52 years). The mean follow-up for 11 hospital survivors is 12.4 years. Three PVA have been replaced; one following infective endocarditis at 13 years, and two at 15 and 73 months due to technical malalignment. There was no evidence of PVA degeneration during histological examination of these explanted PVAs. Six patients are alive and retain the original PVA at 12 years (55%). This analysis corroborates the conclusions of the DNR report and strongly suggests an immunological mechanism in the process of calcification of other biological tissue valves. The Ross operation is advocated for AVR in young patients as valve durability is of paramount importance especially in this group.
[Transcatheter aortic valve replacement].
Sawa, Yoshiki
2014-07-01
While transcatheter aortic valve replacement( TAVR) has spread rapidly all over the world for highrisk patients with severe aortic stenosis (AS), SAPIEN XT was approved in Japan in October 2013. Since that, approximately 400 TAVR cases were performed in Japan. In our institute, we have performed 164 cases since first case in Japan in 2009 and have achieved satisfactory early results(30-day mortality:1.2%). At the same time, however, simultaneously various TAVR-related complications including a paravalvular leak, stroke, vascular complications, and coronary obstruction were observed. A reduction in the incidence and severity of these complications had led technical improvements in various new devices(2nd generation TAVR device such as the SAPIEN 3, ACURATE, and JenaValve) and in implantation techniques including repositioning/recapturing features, paravalvular sealing technologies, and prevention of coronary obstruction. Furthermore, there is also increasing experience with special indications for TAVR such as pure aortic valve insufficiency or valve-in-valve techniques. Currently, an increasing number of publications of midterm results demonstrate good prosthetic valve function and durability, with good quality of life and low morbidity after TAVR. There are also some randomized trials such as PARTNER 2 or SURTAVI to investigate potential benefits of TAVR for intermediate-risk patients. These improvements in the TAVR devices promises the expansion of TAVR towards the treatment of lower-risk patients in the near future.
Aortic cusp extension for surgical correction of rheumatic aortic valve insufficiency in children.
Kalangos, Afksendiyos; Myers, Patrick O
2013-10-01
Surgical management of aortic insufficiency in the young is problematic because of the lack of an ideal valve substitute. Potential advantages of aortic valve repair include low incidences of thromboembolism and endocarditis, avoiding conduit replacements, the maintenance of growth potential, and improved quality of life. Aortic valve repair is still far from fulfilling the three key factors that have allowed the phenomenal development of mitral valve repair (standardization, reproducibility, and stable long-term results); however, techniques of aortic valve repair have been refined, and subsets of patients amenable to repair have been identified. We have focused on the oldest technique of aortic valve repair, cusp extension, focusing on children with rheumatic aortic insufficiency. Among 77 children operated from 2003 to 2007, there was one early death from ventricular failure and one late death from sudden cardiac arrhythmia. During a mean follow-up of 12.8 ± 5.9 years, there were 16 (20.5%) reoperations on the aortic valve, at a median of 3.4 years (range, 2 months to 18.3 years) from repair. Freedom from aortic valve reoperation was 96.2% ± 2.2% at 1 year, 94.9% ± 2.5% at 2 years, 88.5% ± 3.6% at 5 years, 81.7% ± 4.4% at 10 years, 79.7% ± 4.8% at 15 years, and 76.2% ± 5.7% at 20 years. Although aortic cusp extension is technically more demanding, it remains particularly more suitable in the context of evolving rheumatic aortic insufficiency in children with a small aortic annulus as a bridge surgical approach to late aortic valve replacement with a larger valvular prosthesis.
Kiefer, Philipp; Noack, Thilo; Seeburger, Joerg; Hoyer, Alexandro; Linke, Axel; Mangner, Norman; Lehmkuhl, Lukas; Mohr, Friedrich Wilhelm; Holzhey, David
2017-12-01
Transcatheter mitral valve implantation (TMVI) is still in its infancy and is mainly limited to valve-in-valve or valve-in-ring implantations. We present the early experience with TMVI for severe calcified native MV stenosis. Between January 2014 and June 2015, 6 of 11 patients screened (mean age, 77.4 ± 6.3 years; 66% men) with severe native mitral valve (MV) stenosis (mean gradient [Pmean], 11.1 ± 2.1 mm Hg; mean effective orifice area [EOA], 0.9 ± 0.12 cm 2 ) underwent transcatheter MV replacement at our institution as a bailout procedure. Conventional surgical procedures were denied in all patients because of severe annular calcification and extensive comorbidities (mean logistic EuroScore, 31.4% ± 8.3%). The Edwards SAPIEN 3 (29 mm) (Edwards Lifesciences, Irvine, CA) was used in all cases. Procedural access was transapical in 5 cases and concomitant to aortic valve replacement through the left atrium through a sternotomy in 1 case. Initial implantation was successful in 100% of the cases. Because of early migration, 1 patient needed a valve-in-valve procedure. Postoperative echocardiography showed no residual mitral regurgitation in 4 cases (66%) and mild regurgitation in 2 cases (34%). Mean gradients were reduced to 4.2 ± 0.6 mm Hg (mean EOA, 2.8 ± 0.4 cm 2) . No patient had a stroke during hospitalization, and 30-day mortality was seen in 1 patient (17%) resulting from pneumonia. TMV implantation using the SAPIEN 3 aortic prosthesis in patients with heavy annular calcification is feasible and represents a reasonable bailout option for inoperable patients. However, several limitations need to be considered in this special patient population. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Luciani, G B; Santini, F; Auriemma, S; Barozzi, L; Bertolini, P; Mazzucco, A
2001-05-01
This study seeks to define the long-term results after Biocor PSB stentless aortic valve replacement (AVR) in elderly patients, including the effects of No-React treatment. We reviewed the outcomes of 106 consecutive patients, aged 70+/-6 years, having Biocor PSB (93 standard, 13 No-React) AVR between October 1992 and October 1996. There were three early deaths (3%) and 15 late deaths (15%), during a mean follow-up of 5.8+/-1.6 years. At 8 years, survival was 82%+/-4% and freedom from cardiac death was 94%+/-3%. Freedom from valve failure was 92%+/-4% at 8 years (No-React: 92%+/-8% at 4 years). Replacement of the xenograft was required in 5 patients. Freedom from reoperation was 91%+/-4% at 8 years (No-React: 92%+/-8% at 4 years). Four bleeding and two embolic events were recorded: overall valve-related event-free survival was 81%+/-7% at 8 years (No-React: 76%+/-12% at 4 years). Age of long-term survivors averaged 77+/-5 years and their New York Heart Association status was 1.3+/-0.6 (versus 2.9+/-0.6 preoperatively, p = 0.01). Satisfactory freedom from cardiac events and from valve deterioration added to uniform improvement in functional status despite advanced age and high prevalence of comorbid conditions make AVR with the Biocor PSB xenograft a valid long-term therapy for the elderly. No-React treatment does not influence xenograft durability.
Sawa, Yoshiki; Takayama, Morimasa; Mitsudo, Kazuaki; Nanto, Shinsuke; Takanashi, Shuichiro; Komiya, Tatsuhiko; Kuratani, Toru; Tobaru, Tetsuya; Goto, Tsuyoshi
2015-01-01
Transcatheter aortic valve replacement (TAVR) is suggested to be less invasive and/or equally effective in comparison to conventional aortic valve replacement for high-risk symptomatic aortic stenosis patients. We herein report the initial results of a pivotal clinical trial of TAVR in Japan (the PREVAIL JAPAN). Sixty-four aortic stenosis patients (mean age 84.3 ± 6.1 years) not suitable for surgery were enrolled at three centers in Japan, with a primary composite endpoint of the 6-month post-procedure improvements in the aortic valve area and New York Heart Association (NYHA) functional classification. A transfemoral approach was used in 37 patients and a transapical approach was used in 27. The device success rate was 91.9 %. After 30 days and 6 months, the rates of mortality from any cause were 8.1 and 11.3 %, respectively. At 6 months, symptomatic stroke was found in 3.1 % of the patients, and silent infarction in 7.8 %. The aortic valve area and mean pressure gradient were significantly improved over time with both approaches (p < 0.001). At 6 months, the NYHA functional classification based on a conventional physician's assessment was improved in 87.9 % of the patients. We found results that were equivalent to those in other major TAVR trials, such as an acceptable 30-day survival (91.9 %), suggesting that balloon-expandable TAVR is effective for small Japanese AS patients classified as high-risk or inoperable.
Comparison between transcatheter and surgical aortic valve replacement: a single-center experience.
Silberman, Shuli; Abu Akr, Firas; Bitran, Daniel; Almagor, Yaron; Balkin, Jonathan; Tauber, Rachel; Merin, Ofer
2013-07-01
A comparison was made of the outcomes after transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (AVR) in high-risk patients. All patients aged > 75 years that underwent a procedure for severe aortic stenosis with or without coronary revascularization at the authors' institution were included in the study; thus, 64 patients underwent TAVI and 188 underwent AVR. Patients in the TAVI group were older (mean age 84 +/- 5 versus 80 +/- 4 years; p < 0.0001) and had a higher logistic EuroSCORE (p = 0.004). Six patients (9%) died during the procedure in the TAVI group, and 23 (12%) died in the AVR group (p = 0.5). Predictors for mortality were: age (p < 0.0001), female gender (p = 0.02), and surgical valve replacement (p = 0.01). Gradients across the implanted valves at one to three months postoperatively were lower in the TAVI group (p < 0.0001). Actuarial survival at one, two and three years was 78%, 64% and 64%, respectively, for TAVI, and 83%, 78% and 75%, respectively, for AVR (p = 0.4). Age was the only predictor for late mortality (p < 0.0001). TAVI patients were older and posed a higher predicted surgical risk. Procedural mortality was lower in the TAVI group, but mid-term survival was similar to that in patients undergoing surgical AVR. Age was the only predictor for late survival. These data support the referral of high-risk patients for TAVI.
Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.
Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe
2017-07-01
After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.
Impact of Annular Size on Outcomes After Surgical or Transcatheter Aortic Valve Replacement.
Deeb, G Michael; Chetcuti, Stanley J; Yakubov, Steven J; Patel, Himanshu J; Grossman, P Michael; Kleiman, Neal S; Heiser, John; Merhi, William; Zorn, George L; Tadros, Peter N; Petrossian, George; Robinson, Newell; Mumtaz, Mubashir; Gleason, Thomas G; Huang, Jian; Conte, John V; Popma, Jeffrey J; Reardon, Michael J
2018-04-01
This analysis evaluates the relationship of annular size to hemodynamics and the incidence of prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) patients. The CoreValve US Pivotal High Risk Trial, described previously, compared TAVR using a self-expanding valve with SAVR. Multislice computed tomography was used to categorize TAVR and SAVR subjects according to annular perimeter-derived diameter: large (≥26 mm), medium (23 to <26 mm), and small (<23 mm). Hemodynamics, PPM, and clinical outcomes were assessed. At all postprocedure visits, mean gradients were significantly lower for TAVR compared with SAVR in small and medium size annuli (p < 0.001). Annular size was significantly associated with mean gradient after SAVR, with small annuli having the highest gradients (p < 0.05 at all timepoints); gradients were similar across all annular sizes after TAVR. In subjects receiving SAVR, the frequency of PPM was significantly associated with annular size, with small annuli having the greatest incidence. No difference in PPM incidence by annular sizing was observed with TAVR. In addition, TAVR subjects had significantly less PPM than SAVR subjects in small and medium annuli (p < 0.001), with no difference in the incidence of PPM between TAVR and SAVR in large annuli (p = 0.10). Annular size has a significant effect on hemodynamics and the incidence of PPM in SAVR subjects, not observed in TAVR subjects. With respect to annular size, TAVR results in better hemodynamics and less PPM for annuli less than 26 mm and should be strongly considered when choosing a tissue valve for small and medium size annuli. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Roubelakis, Apostolos; Karangelis, Dimos; Sadeque, Syed; Yanagawa, Bobby; Modi, Amit; Barlow, Clifford W; Livesey, Steven A; Ohri, Sunil K
2017-07-01
The treatment of complex prosthetic valve endocarditis (PVE) with aortic root abscess remains a surgical challenge. Several studies support the use of biological tissues to minimize the risk of recurrent infection. We present our initial surgical experience with the use of an aortic xenograft conduit for aortic valve and root replacement. Between October 2013 and August 2015, 15 xenograft bioconduits were implanted for complex PVE with abscess (13.3% female). In 6 patients, concomitant procedures were performed: coronary bypass (n=1), mitral valve replacement (n=5) and tricuspid annuloplasty (n=1). The mean age at operation was 60.3±15.5 years. The mean Logistic European system for cardiac operating risk evaluation (EuroSCORE) was 46.6±23.6. The median follow-up time was 607±328 days (range: 172-1074 days). There were two in-hospital deaths (14.3% mortality), two strokes (14.3%) and seven patients required permanent pacemaker insertion for conduction abnormalities (46.7%). The mean length of hospital stay was 26 days. At pre-discharge echocardiography, the conduit mean gradient was 9.3±3.3mmHg and there was either none (n=6), trace (n=6) or mild aortic insufficiency (n=1). There was no incidence of mid-term death, prosthesis-related complications or recurrent endocarditis. Xenograft bioconduits may be safe and effective for aortic valve and root replacement for complex PVE with aortic root abscess. Although excess early mortality reflects the complexity of the patient population, there was good valve hemodynamics, with no incidence of recurrent endocarditis or prosthesis failure in the mid-term. Our data support the continued use and evaluation of this biological prosthesis in this high-risk patient cohort.
Stub, Dion; Lauck, Sandra; Lee, May; Gao, Min; Humphries, Karin; Chan, Albert; Cheung, Anson; Cook, Richard; Della Siega, Anthony; Leipsic, Jonathon; Charania, Jay; Dvir, Danny; Latham, Tim; Polderman, Jopie; Robinson, Simon; Wong, Daniel; Thompson, Christopher R; Wood, David; Ye, Jian; Webb, John
2015-12-28
This study sought to describe the development of a multicenter, transcatheter aortic valve replacement program and regional systems of care intended to optimize coordinated, efficient, and appropriate delivery of this new therapy. Transcatheter aortic valve replacement (TAVR) has become an accepted treatment option for patients with severe aortic stenosis who are at high surgical risk. Regional systems of care have led to improvements in outcomes for patients undergoing intervention for myocardial infarction, cardiac arrest, and stroke. We implemented a regional system of care for patients undergoing TAVR in British Columbia, Canada. We describe a prospective observational cohort of 583 patients who underwent TAVR in British Columbia between 2012 and 2014. Regionalization of TAVR care in British Columbia refers to a centrally coordinated, funded, and evaluated program led by a medical director and a multidisciplinary advisory group that oversees planning, access to care, and quality of outcomes at the 4 provincial sites. Risk-stratified case selection for transfemoral TAVR is performed by heart teams at each site on the basis of consensus provincial indications. Referrals for lower volume and more complicated TAVR, including nontransfemoral access and valve-in-valve procedures, are concentrated at a single site. In-hospital and 30-day outcomes are reported. The median age was 83 years (interquartile range [IQR]: 78 to 87 years) and median STS score was 6% (IQR: 4% to 8%). Transfemoral access was performed in 499 (85.6%) cases and nontransfemoral in 84 (14.4%). Transcatheter valve-in-valve procedures in for failed bioprosthetic valves were performed in 43 patients (7.4%). A balloon-expandable valve was inserted in 386 (66.2%) and a self-expanding valve in 189 (32.4%). All-cause 30-day mortality was 3.5%. All-cause in-hospital mortality and disabling stroke occurred in 3.1% and 1.9%, respectively. Median length of stay was 3 days (IQR: 3 to 6 days), with 92.8% of patients discharged directly home. This experience demonstrates the potential benefits of a regional system of care for TAVR. Excellent outcomes were demonstrated: most patients had short in-hospital stays and were discharged directly home. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
SLM Produced Hermetically Sealed Isolation Valve
NASA Technical Reports Server (NTRS)
Richard, James
2014-01-01
Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic-driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic-based valve.
Cells for tissue engineering of cardiac valves.
Jana, Soumen; Tranquillo, Robert T; Lerman, Amir
2016-10-01
Heart valve tissue engineering is a promising alternative to prostheses for the replacement of diseased or damaged heart valves, because tissue-engineered valves have the ability to remodel, regenerate and grow. To engineer heart valves, cells are harvested, seeded onto or into a three-dimensional (3D) matrix platform to generate a tissue-engineered construct in vitro, and then implanted into a patient's body. Successful engineering of heart valves requires a thorough understanding of the different types of cells that can be used to obtain the essential phenotypes that are expressed in native heart valves. This article reviews different cell types that have been used in heart valve engineering, cell sources for harvesting, phenotypic expression in constructs and suitability in heart valve tissue engineering. Natural and synthetic biomaterials that have been applied as scaffold systems or cell-delivery platforms are discussed with each cell type. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
SLM Produced Hermetically Sealed Isolation Valve
NASA Technical Reports Server (NTRS)
Richard, James A.
2014-01-01
Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic based valve.
Cheng, Zhuo; Kidher, Emaddin; Jarral, Omar A; O'Regan, Declan P; Wood, Nigel B; Athanasiou, Thanos; Xu, Xiao Yun
2016-05-01
This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.
[Percutaneously implantable aortic valve: the JenaValve concept evolution].
Figulla, Hans R; Ferrari, Markus
2006-10-01
Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.
Energy dynamics of the intraventricular vortex after mitral valve surgery.
Nakashima, Kouki; Itatani, Keiichi; Kitamura, Tadashi; Oka, Norihiko; Horai, Tetsuya; Miyazaki, Shohei; Nie, Masaki; Miyaji, Kagami
2017-09-01
Mitral valve morphology after mitral valve surgery affects postoperative intraventricular flow patterns and long-term cardiac performance. We visualized ventricular flow by echocardiography vector flow mapping (VFM) to reveal the impact of different mitral valve procedures. Eleven cases of mechanical mitral valve replacement (nine in the anti-anatomical and two in the anatomical position), three bioprosthetic mitral valve replacements, and four mitral valve repairs were evaluated. The mean age at the procedure was 57.4 ± 17.8 year, and the echocardiography VFM in the apical long-axis view was performed 119.9 ± 126.7 months later. Flow energy loss (EL), kinetic pressure (KP), and the flow energy efficiency ratio (EL/KP) were measured. The cases with MVR in the anatomical position and with valve repair had normal vortex directionality ("Clockwise"; N = 6), whereas those with MVR in the anti-anatomical position and with a bioprosthetic mitral valve had the vortex in the opposite direction ("Counterclockwise"; N = 12). During diastole, vortex direction had no effect on EL ("Clockwise": 0.080 ± 0.025 W/m; "Counterclockwise": 0.083 ± 0.048 W/m; P = 0.31) or KP ("Clockwise": 0.117 ± 0.021 N; "Counterclockwise": 0.099 ± 0.057 N; P = 0.023). However, during systole, the EL/KP ratio was significantly higher in the "Counterclockwise" vortex than that in the "Clockwise" vortex (1.056 ± 0.463 vs. 0.617 ± 0.158; P = 0.009). MVP and MVR with a mechanical valve in the anatomical position preserve the physiological vortex, whereas MVR with a mechanical valve in the anti-anatomical position and a bioprosthetic mitral valve generate inefficient vortex flow patterns, resulting in a potential increase in excessive cardiac workload.
Mahmood, Feroze; Warraich, Haider J.; Gorman, Joseph H.; Gorman, Robert C.; Chen, Tzong-Huei; Panzica, Peter; Maslow, Andrew; Khabbaz, Kamal
2014-01-01
Background and aim of the study Intraoperative real-time three-dimensional transesophageal echocardiography (RT-3D TEE) was used to examine the geometric changes that occur in the mitral annulus immediately after aortic valve replacement (AVR). Methods A total of 35 patients undergoing elective surgical AVR under cardiopulmonary bypass was enrolled in the study. Intraoperative RT-3D TEE was used prospectively to acquire volumetric echocardiographic datasets immediately before and after AVR. The 3D echocardiographic data were analyzed offline using TomTec® Mitral Valve Assessment software to assess changes in specific mitral annular geometric parameters. Results Datasets were successfully acquired and analyzed for all patients. A significant reduction was noted in the mitral annular area (-16.3%, p <0.001), circumference (-8.9% p <0.001) and the anteroposterior (-6.3%, p = 0.019) and anterolateral-posteromedial (-10.5%, p <0.001) diameters. A greater reduction was noted in the anterior annulus length compared to the posterior annulus length (10.5% versus 62%, p <0.05) after AVR. No significant change was seen in the non-planarity angle, coaptation depth, and closure line length. During the period of data acquisition before and after AVR, no significant change was noted in the central venous pressure or left ventricular end-diastolic diameter. Conclusion The mitral annulus undergoes significant geometric changes immediately after AVR Notably, a 16.3% reduction was observed in the mitral annular area. The anterior annulus underwent a greater reduction in length compared to the posterior annulus, which suggested the existence of a mechanical compression by the prosthetic valve. PMID:23409347
Travancas, Paulo R; Dorigo, Ana H; Simões, Luiz C; Fonseca, Sandra C; Bloch, Kátia V; Herdy, Gesmar V
2009-04-01
To assess the outcomes in children and adolescents with rheumatic fever of the implantation of mechanical as opposed to biological heart valves. We assessed 73 patients with rheumatic heart disease under the age of 18 years, who underwent replacement of heart valves between January, 1996, and December, 2005, at the National Institute of Cardiology in Rio de Janeiro, Brazil. Of the group, 71 patients survived, and were divided into a group of 52 receiving mechanical prostheses, and 19 with biological prostheses. We compared endpoints between the groups in terms of mortality, reoperation, haemorrhage, and stroke. Survival curves were estimated using the Kaplan-Meier method and were compared by the Mantel (log-rank) test. Overall mortality was 8.2%. In those receiving mechanical prostheses, 2 (3.8%) patients died, 5 (9.6%) underwent reoperation, 2 (3.8%) suffered severe haemorrhage, and 3 (5.8%) had strokes. In those receiving biological valves, 2 (10.5%) patients died, and 4 (21%) underwent reoperation. After 2, 4, and 8 years, overall survival was 96%, 93% and 86%, respectively, with a borderline difference between the groups (p = 0.06). The probabilities of remaining free from reoperation (p = 0.13), and from combined endpoints, showed no statistically significant difference between the groups (p = 0.28). Patients with mechanical prostheses had lower mortality and required fewer reoperations, but when all combined endpoints were considered, the groups did not differ. The biological prosthesis proved to be a good option for cardiac surgery in children and adolescents with difficulties or risks of anticoagulation.
The economic value of rapid deployment aortic valve replacement via full sternotomy.
Moore, Matt; Barnhart, Glenn R; Chitwood, W Randolph; Rizzo, John A; Gunnarsson, Candace; Palli, Swetha R; Grossi, Eugene A
2017-06-01
To compare the economic value of EDWARDS INTUITY Elite™ (EIE) valve system for rapid-deployment aortic valve replacement (RDAVR) in a full sternotomy (FS) approach (EIE-FS-RDAVR) versus FS-AVR using conventional stented bioprosthesis. A simulation model to compare each treatment's 30-day inpatient utilization and complication rates utilized: clinical end points obtained from the TRANSFORM trial patient subset (EIE-FS-RDAVR) and a best evidence review of the published literature (FS-AVR); and costs from the Premier database and published literature. EIE-FS-RDAVR costs $800 less than FS-AVR per surgery episode attributable to lowered complication rates and utilization. Combined with the lower mortality, EIE-FS-RDAVR was a superior (dominant) technology versus FS-AVR. This preliminary investigation of EIE-FS-RDAVR versus conventional FS-AVR found the EIE valve offered superior economic value over a 30-day period. Real-world analyses with additional long-term follow-up are needed to evaluate if this result can be replicated over a longer timeframe.
Ishida, Narihiro; Shimabukuro, Katsuya; Matsuno, Yukihiro; Ogura, Hiroki; Takemura, Hirofumi
2014-03-01
A 73-year-old man with a severely stenosed bicuspid valve and an aneurysm of the ascending aorta underwent valve and aortic surgery. Preoperative imaging revealed a single coronary artery arising from the right side of the sinus of Valsalva and a branch that perfused into the left side of the heart to pass through the front of the pulmonary artery. We replaced the aortic valve and ascending aorta, painstakingly avoiding damage to the coronary artery and obstruction of the sole coronary ostium.
Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi
2013-09-01
A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.
Total prosthetic replacement of atrioventricular valves in the dog
Den Otter, G.
1968-01-01
The free-floating cone and cage valve, described in a previous study as being successful as a substitute for the right atrioventricular valve, does not perform well when it is inserted in the mitral ostium. A tilting cone or disc was constructed and tested in a series of 15 dogs. This prosthesis gave excellent results in 12 animals. The reasons for its failure in the remaining three is discussed. The prosthesis presented has advantages over any ball and cage valve, mainly because of its smaller volume. Images PMID:5654076
Percutaneous Pulmonary Valve Placement
Prieto, Lourdes R.
2015-01-01
Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629
Aortic valve replacement in a patient with severe nickel allergy.
Lusini, Mario; Barbato, Raffaele; Spadaccio, Cristiano; Chello, Massimo
2011-11-01
Nickel allergy can raise clinical problems in patients undergoing cardiac surgery who require sternal closure with stainless steel wire. We describe the case of a 51-year-old woman with severe nickel allergy who underwent aortic valve replacement with a nickel-free ON-X prosthesis and sternal closure by Fiberwire # 2 suture without complications. Considering its biocompatibility and its mechanical characteristics including optimal strength and knot resistance, this suture might be a viable alternative in patients in which the use of stainless steel wire is contraindicated. © 2011 Wiley Periodicals, Inc.
Koza, Yavuzer; Taş, Muhammed Hakan; Şimşek, Ziya; Gündoğdu, Fuat
2016-10-01
Cardiac conduction defects are commonly observed in patients with ankylosing spondylitis, infective endocarditis, and aortic valve replacement. Each of these clinical situations can also present with ventricular tacyhcardia by different mechanisms. Here we report the case of a 53-year-old man with a medical history of untreated ankylosing spondylitis and aortic valve replacement who presented with ventricular tachycardia and underwent successful catheter ablation. Most ventricular tachycardia episodes were intermittent and drug resistant, which could have been caused by abnormal automaticity rather than re-entry.
Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik
2014-12-01
Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.
The early and midterm function of decellularized aortic valve allografts.
da Costa, Francisco D A; Costa, Ana Claudia B A; Prestes, Roberta; Domanski, Ana Carolina; Balbi, Eduardo Mendel; Ferreira, Andreia D A; Lopes, Sergio Veiga
2010-12-01
This study evaluates the early and midterm results of decellularized aortic valve allografts (DAVA) as an aortic valve replacement. Between October 2005 and February 2010, 41 patients, 28 of whom were male, with a median age of 34 years (range, 0.1 to 71), had aortic valve replacement with DAVA. Decellularization was obtained with a 0.1% sodium dodecyl sulfate solution. Postoperative evaluation was performed with serial echocardiograms, magnetic resonance imaging, and multislice computed tomography studies to evaluate valve hemodynamics, allograft conduit dimensions, and calcification scores. There were 3 early deaths and 1 late death, with a mean follow-up of 19 months (range, 1 to 53). There was 1 reoperation due to a failed mitral valve repair. By echocardiography in all patients, the median immediate postoperative peak gradient was 7 mm Hg (range, 1 to 26 mm Hg), and at last follow-up it was 4 mm Hg (range, 1 to 16 mm Hg); valvular regurgitation was graded as none or trivial in all but 1 patient, who had a regurgitation graded as mild to moderate. By magnetic resonance imaging (n = 4), mean root dimensions were stable at the annulus (24 mm), sinus of Valsalva (33 mm), and sinotubular junction (28 mm). By computed tomography (n = 22), there was only discrete conduit calcification (median calcium score 63 Hounsfield units [HU]; range, 0 to 894 HU) to 3 years of follow-up. Conduit biopsy in the patient who underwent reoperation demonstrated well-preserved wall structure, absence of calcification, and limited in vivo host repopulation. The early and midterm results with DAVA demonstrated stable structural integrity, low rate of calcification, and adequate hemodynamics. Although longer periods of observation are necessary, DAVA appears to be a promising alternative for aortic valve replacement in selected patients. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ailawadi, Gorav; LaPar, Damien J; Speir, Alan M; Ghanta, Ravi K; Yarboro, Leora T; Crosby, Ivan K; Lim, D Scott; Quader, Mohammed A; Rich, Jeffrey B
2016-01-01
The Placement of Aortic Transcatheter Valve (PARTNER) trial suggested an economic advantage for transcatheter aortic valve replacement (TAVR) for high-risk patients. The purpose of this study was to evaluate the cost effectiveness of TAVR in the "real world" by comparing TAVR with surgical aortic valve replacement (SAVR) in intermediate-risk and high-risk patients. A multiinstitutional database of The Society of Thoracic Surgeons (STS) (2011 to 2013) linked with estimated cost data was evaluated for isolated TAVR and SAVR operations (n = 5,578). TAVR-treated patients (n = 340) were 1:1 propensity matched with SAVR-treated patients (n = 340). Patients undergoing SAVR were further stratified into intermediate-risk (SAVR-IR: predicted risk of mortality [PROM] 4% to 8%) and high-risk (SAVR-HR: PROM >8%) cohorts. Median STS PROM for TAVR was 6.32% compared with 6.30% for SAVR (SAVR-IR 4.6% and SAVR-HR 12.4%). A transfemoral TAVR approach was most common (61%). Mortality was higher for TAVR (10%) compared with SAVR (6%, p < 0.047), whereas the SAVR group accrued higher major morbidity (27% vs 14%, p < 0.001) and longer postoperative hospital duration (7 days vs 6 days, p < 0.001). Importantly, TAVR incurred twice the median total costs compared with SAVR ($69,921 vs $33,598, p < 0.001). The increased cost of TAVR was largely driven by the cost of the valve (all p < 0.001). Intermediate-risk patients undergoing SAVR demonstrated the most exaggerated cost savings versus TAVR. TAVR was associated with greater total costs and mortality compared with SAVR in intermediate-risk and high-risk patients while conferring lower major morbidity and improved resource use. Increased cost of TAVR appears largely related to the cost of the valve. Until the price of TAVR valves decreases, these data suggest that TAVR may not provide the most cost-effective strategy, particularly for intermediate-risk patients. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Aortic biological valve thrombosis in an HIV positive patient.
Achouh, Paul; Jemel, Amine; Chaudeurge, Aurélie; Redheuil, Alban; Zegdi, Rachid; Fabiani, Jean-Noël
2011-06-01
Biological aortic valve thrombosis is an exceptional complication. A 64-year-old patient positive for human immunodeficiency virus presented for syncope on exertion, 2 years after an aortic bioprosthetic valve replacement and double coronary artery bypass. Transvalvular aortic mean gradient was approximately 50 mm Hg on echocardiogram and catheterization. Cardiac computed tomography scan showed a limited opening of the bioprosthesis cusps. Surgical exploration revealed thrombosis of the three cusps on the aortic side, limiting the opening of the valve. No relation could be established between the patient's human immunodeficiency virus status and valve thrombosis. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Han, Bin; Cao, Lei; Zheng, Li; Zang, Jia-ye; Wang, Xiao-ru
2012-01-01
Using three pipe clamp solenoid valves to replace the traditional six-port valve for sample quota, a set of multi-channel flow injection analyzer was designed in the present paper. The authors optimized optimum instrumental testing condition, and realized determination and analysis of total dissolved nitrogen in seawaters. The construction of apparatus is simple and it has the potential to be used for analysis of total dissolved nitrogen. The sample throughput of total dissolved nitrogen was 27 samples per hour. The linear range of total dissolved nitrogen was 50.0-1 000.0 microgN x L(-3) (r > or = 0.999). The detection limit was 7.6 microgN x L(-3). The recovery of total dissolved nitrogen was 87.3%-107.2%. The relative standard deviation for total dissolved nitrogen was 1.35%-6.32% (n = 6). After the t-test analysis, it does not have the significance difference between this method and national standard method. It is suitable for fast analysis of total dissolved nitrogen in seawater.
Wang, Bin; Xu, Zhi-yun; Han, Lin; Zhang, Guan-xin; Lu, Fang-lin; Song, Zhi-gang
2013-03-01
The prognostic significance of preoperative atrial fibrillation on mitral valve replacement remains unclear. The aim of this study was to explore the effects of the presence of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mitral valve replacement for rheumatic valve disease. A retrospective analysis was performed on a total of 793 patients who underwent mitral valve replacement with or without tricuspid valve repair in our hospital. The patients selected were divided into two groups according to preoperative rhythm status. Patients with preoperative atrial fibrillation were assigned to the AF group, while patients in preoperative sinus rhythm were assigned to the SR group. Postoperative follow-up was performed by outpatient visits, as well as by telephone and written correspondence. Data gathered included survivorship, postoperative complications, left ventricular function and tricuspid regurgitation. For patients with atrial fibrillation vs those in sinus rhythm, there was no difference in postoperative mortality and morbidity. Follow-up was a mean of 8.6 ± 2.4 years. For patients with preoperative atrial fibrillation, 10-year survival from a Kaplan-Meier curve was 88.7%, compared with 96.6% in patients with preoperative sinus rhythm (P = 0.002). Multivariate analysis identified low left ventricular ejection fraction, older age, large left atrium and preoperative atrial fibrillation as significant adverse predictors for overall survival. Freedom from thromboembolism complications at 13 years was lower for patients with preoperative atrial fibrillation without maze procedure and left atrial appendage ligation, compared with that for patients with preoperative sinus rhythm without maze procedure and left atrial appendage ligation, and patients with concomitant maze procedure and left atrial appendage ligation (76.3 vs 94.8 vs 94.0%, respectively; P = 0.001). On echocardiography, the proportion of patients with significant tricuspid regurgitation was 38.7% (atrial fibrillation patients) vs 25.4% (patients in sinus rhythm; P < 0.001). Left ventricular ejection fraction measured 5 years after surgery increased by an average of 1.2% in the AF group, while it increased by 5.3% in the SR group (P = 0.028). Preoperative atrial fibrillation is a risk factor for long-term mortality, thromboembolism complications and tricuspid regurgitation, and it also has an adverse effect on the degree of improvement when considering left ventricular function.
Sponga, Sandro; Mazzaro, Enzo; Bagur, Rodrigo; Livi, Ugolino
2017-04-01
A 40-year-old man underwent 4 aortic surgeries because of endocarditis and subsequent prosthesis dehiscence. At the last recurrence he presented with acute severe aortic regurgitation of a Pericarbon Freedom (LivaNova plc, London, UK) stentless bioprosthesis and a morphologically disarranged aortic root. He also presented with left ventricular dysfunction and a very low origin of the left coronary artery. Therefore, a fifth redo aortic valve replacement was considered at high surgical risk. Accordingly, before listing the patient for a heart transplantation, a transcatheter valve-in-valve implantation with the JenaValve (JenaValve Technology, GmbH, Munich, Germany) prosthesis was performed. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.
Badiu, Catalin C; Bleiziffer, Sabine; Eichinger, Walter B; Hettich, Ina; Krane, Markus; Bauernschmitt, Robert; Lange, Rüdiger
2011-03-01
The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the stented Hancock valve substitute. The key benefit of this bioprosthetic valved conduit was the simplified redo procedure.
Choudhary, Shiv Kumar; Abraham, Atul; Bhoje, Amol; Gharde, Parag; Sahu, Manoj; Talwar, Sachin; Airan, Balram
2017-11-01
The present study evaluates the feasibility, safety, and efficacy of edge-to-edge repair for moderate secondary/functional mitral regurgitation in patients undergoing aortic valve/root interventions. Sixteen patients underwent transaortic edge-to-edge mitral valve repair. Mitral regurgitation was 2+ in 8 patients and 3+ in 6 patients. Two patients in whom cardiac arrest developed preoperatively had severe (4+) mitral regurgitation. Patients underwent operation for severe aortic regurgitation ± aortic root lesions. The mean left ventricular systolic and diastolic diameters were 51.5 ± 12.8 mm and 70.7 ± 10.7 mm, respectively. Left ventricular ejection fraction ranged from 20% to 60%. Primary surgical procedure included Bentall's ± hemiarch replacement in 10 patients, aortic valve replacement in 5 patients, and noncoronary sinus replacement with aortic valve repair in 1 patient. Severity of mitral regurgitation decreased to trivial or zero in 13 patients, 1+ in 2 patients, and 2+ in 1 patient. There were no gradients across the mitral valve in 9 patients, less than 5 mm Hg in 6 patients, and 9 mm Hg in 1 patient. There was no operative mortality. Follow-up ranged from 2 weeks to 54 months. Echocardiography showed trivial or no mitral regurgitation in 12 patients, 1+ in 2 patients, and 2+ in 2 patients. None of the patients had significant mitral stenosis. The mean left ventricular systolic and diastolic diameters decreased to 40.5 ± 10.3 mm and 58.7 ± 11.6 mm, respectively. Ejection fraction also improved slightly (22%-65%). Transaortic edge-to-edge mitral valve repair is a safe and effective technique to abolish secondary/functional mitral regurgitation. However, its impact on overall survival needs to be studied. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Interventional valve surgery: building a team and working together.
Ruel, Marc; Dickie, Sean; Chow, Benjamin J W; Labinaz, Marino
2010-01-01
Transcatheter aortic valve implantation (TAVI) is a new modality that may change the therapeutic landscape in the management of aortic valve stenosis. Despite the excellent results of surgical aortic valve replacement, TAVI has the potential to revolutionize the treatment of elderly and high-risk patients with aortic stenosis. It therefore constitutes a new reality that cardiac surgeons have to acknowledge. As TAVI indications and techniques become better defined, the importance of a team approach to the implementation and performance of TAVI is becoming increasingly evident. The surgeon has a crucial role to play in the introduction, development, and sustainability of TAVI at any institution. In this article, we discuss the procedural technique involved in TAVI, as well as the cardiologist and heart surgeon individualities and team dynamics. We make a case for judicious team-based adoption of TAVI technologies, considering that evidence-based and health economics data are not yet available. We also illustrate how a team approach may lead to improved outcomes, better patient and institutional acceptance, and a better definition of the therapeutic niche of TAVI modalities, amid the excellent results of conventional aortic valve replacement surgery. Copyright © 2010 Elsevier Inc. All rights reserved.
Instenes, Irene; Gjengedal, Eva; Eide, Leslie S P; Kuiper, Karel K J; Ranhoff, Anette H; Norekvål, Tone M
2018-02-01
Surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are increasingly performed in octogenarian patients with severe aortic stenosis (AS), including those with high surgical risk. Postoperative delirium (PD) is a common and serious complication in older patients, characterised by reduced awareness, change in consciousness, disturbance in logical thinking and hallucinations. To explore how octogenarian patients experienced PD, a qualitative study was conducted including five women and five men between 81 and 88 years. The incidence of PD was assessed for five days using the Confusion Assessment Method. Cognitive function was assessed preoperatively and at a 6-month follow-up using the Mini-Mental State Examination. In-depth interviews were conducted 6-12 months post-discharge, transcribed, and analysed using Giorgi's phenomenological method. Postoperative delirium experiences were grouped into six themes: "Like dreaming while awake", "Disturbed experiences of time", "Existing in a twilight zone", "Trapped in medical tubes", "Moving between different surroundings" and "Meeting with death and the deceased". For the first time, we show that octogenarian patients who undergo SAVR or TAVI have strong and distressing memories of their delirious state that can persist for up to 12 months later. These findings provide valuable new information that will likely improve delivery of health services and enhance professional and empathic care of octogenarians after SAVR and TAVI. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Validity of standard gamble utilities in patients referred for aortic valve replacement.
Hussain, Amjad I; Garratt, Andrew M; Beitnes, Jan Otto; Gullestad, Lars; Pettersen, Kjell I
2016-07-01
Standard gamble (SG) is the preferred method of assessing preferences in situations with uncertainty and risk, which makes it relevant to patients considered for aortic valve replacement (AVR). The present study assesses SG preferences in patients with severe aortic stenosis (AS). All patients >18 years old with severe AS referred for AVR to our institution were invited to enroll in the study. The SG was administered by a clinical research nurse. The SF-36, EQ-5D 3L, Hospital Anxiety and Depression Scale (HADS), and AS symptoms were administered by self-completed questionnaire. We hypothesized that SG utilities would have low-to-moderate correlations with physical and mental aspects of health based on our pathophysiological understanding of severe AS. No correlations were expected with echocardiographic measures of the aortic valve. The response rate for SG was 98 %. SG moderately correlated with physical aspects of SF-36 (PCS, role-physical, vitality), health transition, AS symptoms, and EQ-VAS (ρ S = 0.31-0.39, p < 0.001) and had low correlation with mental aspects of SF-36 and EQ-5D (ρ S = 0.17-0.28, p < 0.001). No correlation was found between SG and HADS, echocardiographic measures, age, gender, or education level (ρ S = 0.01-0.06). SG is an acceptable and feasible method of assessing preferences in patients with severe AS that has evidence for validity. The inclusion of uncertainty lends the SG face validity in this population as a direct approach to assessing preferences and basis for QALY calculations.
Husser, Oliver; Fujita, Buntaro; Hengstenberg, Christian; Frerker, Christian; Beckmann, Andreas; Möllmann, Helge; Walther, Thomas; Bekeredjian, Raffi; Böhm, Michael; Pellegrini, Costanza; Bleiziffer, Sabine; Lange, Rüdiger; Mohr, Friedrich; Hamm, Christian W; Bauer, Timm; Ensminger, Stephan
2018-03-26
The aims of this study were to report on the use of local anesthesia or conscious sedation (LACS) and general anesthesia in transcatheter aortic valve replacement and to analyze the impact on outcome. Transcatheter aortic valve replacement can be performed in LACS or general anesthesia. Potential benefits of LACS, such as faster procedures and shorter hospital stays, need to be balanced with safety. A total of 16,543 patients from the German Aortic Valve Registry from 2011 to 2014 were analyzed, and propensity-matched analyses were performed to correct for potential selection bias. LACS was used in 49% of patients (8,121 of 16,543). In hospital, LACS was associated with lower rates of low-output syndrome, respiratory failure, delirium, cardiopulmonary resuscitation, and death. There was no difference in paravalvular leakage (II+) between LACS and general anesthesia in the entire population (5% vs. 4.8%; p = 0.76) or in the matched population (3.9% vs. 4.9%, p = 0.13). The risk for prolonged intensive care unit stay (≥3 days) was significantly reduced with LACS (odds ratio: 0.82; 95% confidence interval [CI]: 0.73 to 0.92; p = 0.001). Thirty-day mortality was lower with LACS in the entire population (3.5% vs. 4.9%; hazard ratio [HR]: 0.72; 95% CI: 0.60 to 0.86; p < 0.001) and in the matched population (2.8% vs. 4.6%; HR: 0.6; 95% CI: 0.45 to 0.8; p < 0.001). However, no differences in 1-year mortality between both groups in the entire population (16.5% vs. 16.9%; HR: 0.93; 95% CI: 0.85 to 1.02; p = 0.140) and in the propensity-matched population (14.1% vs. 15.5%; HR: 0.90; 95% CI: 0.78 to 1.03; p = 0.130) were observed. Use of LACS in transcatheter aortic valve replacement is safe, with fewer post-procedural complications and lower early mortality, suggesting its broad application. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Huded, Chetan P; Masri, Ahmad; Kusunose, Kenya; Goodman, Andrew L; Grimm, Richard A; Gillinov, A Marc; Johnston, Douglas R; Rodriguez, L Leonardo; Popovic, Zoran B; Svensson, Lars G; Griffin, Brian P; Desai, Milind Y
2018-04-12
In asymptomatic patients with severe aortic stenosis and preserved left ventricular ejection fraction, we sought to assess the incremental prognostic value of resting valvuloarterial impedence (Zva) and left ventricular global longitudinal strain (LV-GLS) to treadmill stress echocardiography. We studied 504 such patients (66±12 years, 78% men, 32% with coronary artery disease who underwent treadmill stress echocardiography between 2001 and 2012. Clinical and exercise variables (% of age-sex predicted metabolic equivalents [%AGP-METs]) were recorded. Resting Zva ([systolic arterial pressure+mean aortic valve gradient]/[LV-stroke volume index]) and LV-GLS (measured offline using Velocity Vector Imaging, Siemens) were obtained from the baseline resting echocardiogram. Death was the primary outcome. There were no major adverse cardiac events during treadmill stress echocardiography. Indexed aortic valve area, Zva, and LV-GLS were 0.46±0.1 cm 2 /m 2 , 4.5±0.9 mm Hg/mL per m 2 and -16±4%, respectively; only 50% achieved >100% AGP-METs. Sixty-four percent underwent aortic valve replacement. Death occurred in 164 (33%) patients over 8.9±3.6 years (2 within 30 days of aortic valve replacement). On multivariable Cox survival analysis, higher Society of Thoracic Surgeons score (hazard ratio or HR 1.06), lower % AGP-METS (HR 1.16), higher Zva (HR 1.25) and lower LV-GLS (HR 1.12) were associated with higher longer-term mortality, while aortic valve replacement (HR 0.45) was associated with improved survival (all P <0.01). Sequential addition of ZVa and LV-GLS to clinical model (Society of Thoracic Surgeons score and %AGP-METs) increased the c-statistic from 0.65 to 0.69 and 0.75, respectively, both P <0.001); findings were similar in the subgroup of patients who underwent aortic valve replacement. In asymptomatic patients with severe aortic stenosis undergoing treadmill stress echocardiography, LV-GLS and ZVa offer incremental prognostic value. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Cold crystalloid versus warm blood cardioplegia in patients undergoing aortic valve replacement.
Nardi, Paolo; Vacirca, Sara R; Russo, Marco; Colella, Dionisio F; Bassano, Carlo; Scafuri, Antonio; Pellegrino, Antonio; Melino, Gerry; Ruvolo, Giovanni
2018-03-01
Myocardial protection techniques during cardiac arrest have been extensively investigated in the clinical setting of coronary revascularization. Fewer studies have been carried out of patients affected by left ventricular hypertrophy, where the choice of type and temperature of cardioplegia remain controversial. We have retrospectively investigated myocardial injury and short-term outcome in patients undergoing aortic valve replacement plus or minus coronary artery bypass grafting with using cold crystalloid cardioplegia (CCC) or warm blood cardioplegia (WBC). From January 2015 to October 2016, 191 consecutive patients underwent aortic valve replacement plus or minus coronary artery bypass grafting in normothermic cardiopulmonary bypass. Cardiac arrest was obtained with use of intermittent antegrade CCC group (n=32) or WBC group (n=159), according with the choice of the surgeon. As compared with WBC group, in CCC group creatine-kinase-MB (CK-MB), cardiac troponin I (cTnI), aspartate aminotransferase (AST) release, and their peak levels, were lower during each time points of evaluation, with the greater statistically significant difference at time 0 (P<0.05, for all comparisons). A time 0, CK-MB/CK ratio >10% was 5.9% in CCC group versus 7.8% in WBC group (P<0.0001). At time 0 CK-MB/CK ratio >10% in patients undergoing isolated aortic valve replacement was 6.0% in CCC group versus 8.0% in WBC group (P<0.01). No any difference was found in perioperative myocardial infarction (0% versus 3.8%), postoperative (PO) major complications (15.6% versus 16.4%), in-hospital mortality (3.1% versus 1.3%). In aortic valve surgery a significant decrease of myocardial enzymes release is observed in favor of CCC, but this difference does not translate into different clinical outcome. However, this study suggests that in presence of cardiac surgical conditions associated with significant left ventricular hypertrophy, i.e., the aortic valve disease, a better myocardial protection can be achieved with the use of a cold rather than a warm cardioplegia. Therefore, CCC can be still safely used.
Sickle cell anemia and mitral valve replacement. Case report.
Bomfim, V; Ribeiro, A; Gouvea, F; Pereira, J; Björk, V
1989-01-01
An 8-year-old black boy with sickle cell disease and severe hemolytic anemia crisis (95% hemoglobin S) also had mitral incompetence due to rheumatic valve disease. A 27 mm monostrut Björk-Shiley valve prosthesis was implanted after partial exchange transfusions had reduced the hemoglobin S to less than 40%. High-flow normothermic perfusion was used during extracorporeal circulation, with care taken to avoid hypoxia and acidosis. Postoperative recovery was uneventful.
Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.
O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel
2017-03-01
Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.
Schofer, Joachim; Nietlispach, Fabian; Bijuklic, Klaudija; Colombo, Antonio; Gatto, Fernando; De Marco, Federico; Mangieri, Antonio; Hansen, Lorenz; Bruschi, Giuseppe; Ruparelia, Neil; Rieß, Friedrich-Christian; Maisano, Franscesco; Latib, Azeem
2015-12-21
This study sought to evaluate the use of the Direct Flow Medical (DFM) transcatheter heart valve (Direct Flow Medical, Santa Rosa, California) for the treatment of noncalcific pure aortic regurgitation (AR). The treatment of noncalcific AR has remained a relative contraindication with transcatheter heart valves due to challenges in anchoring devices in the absence of calcium, concerns of valve embolization, and the high risk of significant residual paravalvular leak. The study population consisted of patients treated for severe noncalcific pure AR with transfemoral implantation of a DFM transcatheter heart valve at 6 European centers. The primary endpoint was the composite endpoint of device success and the secondary endpoint was the composite early safety endpoint (according to the VARC-2 criteria). Eleven high-risk (STS score 8.84 ± 8.9, Logistic EuroSCORE 19.9 ± 7.1) patients (mean age 74.7 ± 12.9 years) were included. Device success was achieved in all patients. In 1 patient, the initial valve prosthesis was retrieved after pull-through, and a second valve was successfully deployed. The early safety endpoint was reached in 91% of the patients, with 1 patient requiring surgical aortic valve replacement secondary to downward dislocation of the prosthesis that was successfully managed with surgical aortic valve replacement. DFM implantation resulted in excellent hemodynamics with none or trivial paravalvular regurgitation in 9 patients and a transprosthetic gradient of 7.7 ± 5.1 mm Hg at 30-day follow up. All patients derived symptomatic benefit following the procedure, with 72% in New York Heart Association functional class I or II. This study reports the feasibility of treating severe noncalcific AR with the Direct Flow prosthesis via the transfemoral route. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Narang, Nikhil; Lang, Roberto M; Liarski, Vladimir M; Jeevanandam, Valluvan; Hofmann Bowman, Marion A
2017-01-01
A 55-year-old man with a history of erosive, seropositive rheumatoid arthritis (RA), and interstitial lung disease presented with shortness of breath. Echocardiography showed new-onset severe left ventricular (LV) dysfunction with an ejection fraction (EF) of 15% and moderately increased mean aortic valve gradient of 20 mmHg in a trileaflet aortic valve with severe sclero-calcific degeneration. Coronary angiography revealed no significant obstructive coronary disease. Invasive hemodynamic studies and dobutamine stress echocardiography were consistent with moderate aortic stenosis. Guideline directed medical therapy for heart failure with reduced EF was initiated; however, diuretics and neurohormonal blockade (beta-blocker and angiotensin receptor blocker) provided minimal improvement, and the patient remained functionally limited. Of interest, echocardiography performed 1 year prior to his presentation showed normal LV EF and mild aortic leaflet calcification with moderate stenosis, suggesting a rapid progressing of calcific aortic valve disease. Subsequently, the patient underwent surgical aortic valve replacement and demonstrated excellent postsurgical recovery of LV EF (55%). Calcific aortic valve disease is commonly associated with aging, bicuspid aortic valve, and chronic kidney disease. Pathophysiological mechanism for valvular calcification is incompletely understood but include osteogenic transformation of valvular interstitial cells mediated by local and systemic inflammatory processes. Several rheumatologic diseases including RA are associated with premature atherosclerosis and arterial calcification, and we speculated a similar role of RA accelerating calcific aortic valve disease. We present a case of accelerated aortic valve calcification with (only) moderate stenosis, complicated by a rapid decline in LV systolic performance. Guidelines for AVR in moderate stenosis without concomitant cardiac surgery are not well established, although it should be considered in selected patients.
Baraki, Hassina; Al Ahmad, Ammar; Sarikouch, Samir; Koigeldiev, Nurbol; Khaladj, Nawid; Hagl, Christian; Pichlmaier, Maximillian; Haverich, Axel; Shrestha, Malakh
2010-05-01
Composite replacement is the standard treatment for the repair of aortic aneurysm with aortic valve pathology. With improved long-term durability and no requirement for long-term anticoagulation, tissue-valved conduits have become increasingly popular. Herein are reported the results achieved with 50 consecutive 'Bentall' operations, using the first commercially available prefabricated stentless tissue-valved conduit (Vascutek BioValsalva). Between September 2007 and September 2009, a total of 50 patients (10 females, 40 males; mean age 65 +/- 7 years) received a BioValsalva conduit. Concomitant procedures included coronary artery bypass grafting (CABG; n = 15), other valve (n = 5), and aortic arch replacement with circulatory arrest (n = 20; three of these had an additional frozen elephant trunk). Four of the procedures were re-operations. A six-month follow up with echocardiography and clinical examination was completed in 25 patients. The 30-day mortality was 8% (4/50). Three of these patients underwent concomitant procedures. The cardiopulmonary bypass (CPB) and cross-clamp times were 178 +/- 30 min and 106 +/- 7 min, respectively. The triple-layered vascular graft proved to be hemostatic, without suture-line bleeding. Both, the initial and follow up echocardiography showed no valvular insufficiency, with a mean gradient of 13 +/- 5 mmHg. All patients were in NYHA class I-II. The BioValsalva prefabricated tissue-valved conduit showed very good early results. The ischemic time required to construct a 'home-made' stentless tissue-valved conduit was eliminated, thus reducing the cross-clamp time. The conduit also offered the hemodynamic advantages of a stentless valve.
Praz, Fabien; Siontis, George C M; Verma, Subodh; Windecker, Stephan; Jüni, Peter
2017-03-01
The goal of this review is to summarize the current evidence supporting the use of transcatheter aortic valve implantation (TAVI) in high and intermediate-risk patients. The focus is on the five randomized controlled trials comparing TAVI with surgical aortic valve replacement (SAVR) published to date, as well as two recent meta-analyses. TAVI has profoundly transformed the treatment of elderly patients presenting with symptomatic severe aortic stenosis. In experienced hands, the procedure has become well tolerated and the results more predictable. So far, two trials using two different devices [Placement of Aortic Transcatheter Valve (PARTNER) 1A and US CoreValve High Risk] have shown that TAVI is able to compete in terms of mortality with SAVR in high-risk patients. These findings have been extended to the intermediate-risk population in two recently published randomized controlled trials [PARTNER 2 and Nordic Aortic Valve Intervention (NOTION)]. The two meta-analyses suggested improved survival in both high and intermediate-risk patients during the first 2 years following the intervention. The survival benefit was only found in patients treated via the transfemoral access, and appeared more pronounced in women. Individual randomized trials enrolling high and intermediate-risk patients have established the noninferiority of TAVI in comparison with SAVR, whereas subsequent meta-analyses suggest superiority of transfemoral TAVI in terms of a sustained survival benefit 2 years after valve implantation irrespective of the surgical risk category. The benefit of TAVI appears more pronounced in women than in men.
Statins for aortic valve stenosis.
Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib
2016-01-01
Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0.14; participants = 155; study = 1). Moderate-quality evidence showed no effect on freedom from valve replacement with statins (risk ratio (RR) 0.93, 95% CI 0.81 to 1.06; participants = 2360; studies = 4), and no effect on muscle pain as an adverse event (RR 0.91, 95% CI 0.75 to 1.09; participants = 2204; studies = 3; moderate-quality evidence). Low- and very low-quality evidence showed uncertainty around the effect of statins on death from cardiovascular cause (RR 0.80, 95% CI 0.56 to 1.15; participants = 2297; studies = 3; low-quality evidence) and hospitalization for any reason (RR 0.84, 95% CI 0.39 to 1.84; participants = 155; study = 1; very low-quality evidence). None of the four included studies reported on overall mortality and patient quality of life. Result findings showed uncertainty surrounding the effect of statins for aortic valve stenosis. The quality of evidence from the reported outcomes ranged from moderate to very low. These results give support to European and USA guidelines (2012 and 2014, respectively) that so far there is no clinical treatment option for aortic valve stenosis.