Sample records for valve replacement pvr

  1. Comparison of valvar and right ventricular function following transcatheter and surgical pulmonary valve replacement.

    PubMed

    Li, Wendy F; Pollard, Heidi; Karimi, Mohsen; Asnes, Jeremy D; Hellenbrand, William E; Shabanova, Veronika; Weismann, Constance G

    2018-01-01

    Trans-catheter (TC) pulmonary valve replacement (PVR) has become common practice for patients with right ventricular outflow tract obstruction (RVOTO) and/or pulmonic insufficiency (PI). Our aim was to compare PVR and right ventricular (RV) function of patients who received TC vs surgical PVR. Retrospective review of echocardiograms obtained at three time points: before, immediately after PVR, and most recent. Sixty-two patients (median age 19 years, median follow-up 25 months) following TC (N = 32) or surgical (N = 30) PVR at Yale-New Haven Hospital were included. Pulmonary valve and right ventricular function before, immediately after, and most recently after PVR. At baseline, the TC group had predominant RVOTO (74% vs 10%, P < .001), and moderate-severe PI was less common (61% vs 100%, P < .001). Immediate post-procedural PVR function was good throughout. At last follow-up, the TC group had preserved valve function, but the surgical group did not (moderate RVOTO: 6% vs 41%, P < .001; >mild PI: 0% vs 24%, P = .003). Patients younger than 17 years at surgical PVR had the highest risk of developing PVR dysfunction, while PVR function in follow-up was similar in adults. Looking at RV size and function, both groups had a decline in RV size following PVR. However, while RV function remained stable in the TC group, there was a transient postoperative decline in the surgical group. TC PVR in patients age <17 years is associated with better PVR function in follow-up compared to surgical valves. There was a transient decline in RV function following surgical but not TC PVR. TC PVR should therefore be the first choice in children who are considered for PVR, whenever possible. © 2017 Wiley Periodicals, Inc.

  2. Retrograde transcatheter device closure of a complex paravalvular leak after bioprosthetic pulmonary valve replacement in a pediatric patient.

    PubMed

    Chikkabyrappa, Sathish; Mosca, Ralph S; McElhinney, Doff B

    2016-06-01

    We report a case of retrograde transcatheter device closure of a complex paravalvular leak (PVL) after bioprosthetic pulmonary valve replacement (PVR) in a 13-year-old patient with congenital pulmonary valve stenosis. There are prior reports of pulmonary PVL closure after PVR in adults (Seery and Slack, Congenit Heart Dis 2014;9:E19-F22), but indications for and technical considerations in PVL closure after bioprosthetic PVR, particularly in children, are not well defined. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  3. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.

    PubMed

    Khalique, Omar K; Hahn, Rebecca T; Gada, Hemal; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Kalesan, Bindu; Forster, Molly; Williams, Mathew B; Leon, Martin B; Einstein, Andrew J; Pulerwitz, Todd C; Pearson, Gregory D N; Kodali, Susheel K

    2014-08-01

    This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) immediately after transcatheter aortic valve replacement (TAVR). The impact of AVC in different locations within the aortic valve complex is incompletely understood. This study analyzed 150 patients with severe, symptomatic aortic stenosis who underwent TAVR. Total AVC volume scores were calculated from contrast-enhanced multidetector row computed tomography imaging. AVC was divided by leaflet sector and region (Leaflet, Annulus, left ventricular outflow tract [LVOT]), and a combination of LVOT and Annulus (AnnulusLVOT). Asymmetry was assessed. Receiver-operating characteristic analysis was performed with greater than or equal to mild PVR and PD as classification variables. Logistic regression was performed. Quantity of and asymmetry of AVC for all regions of the aortic valve complex predicted greater than or equal to mild PVR by receiver-operating characteristic analysis (area under the curve = 0.635 to 0.689), except Leaflet asymmetry. Receiver-operating characteristic analysis for PD was significant for quantity and asymmetry of AVC in all regions, with higher area under the curve values than for PVR (area under the curve = 0.648 to 0.741). On multivariable analysis, Leaflet and AnnulusLVOT calcification were independent predictors of both PVR and PD regardless of multidetector row computed tomography area cover index. Quantity and asymmetry of AVC in all regions of the aortic valve complex predict greater than or equal to mild PVR and performance of PD, with the exception of Leaflet asymmetry. Quantity of AnnulusLVOT and Leaflet calcification independently predict PVR and PD when taking into account multidetector row computed tomography area cover index. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Sustained Improvement in Right Ventricular Chamber Dimensions 10 Years Following Xenograft Pulmonary Valve Replacement.

    PubMed

    Schubmehl, Heidi B; Swartz, Michael F; Atallah-Yunes, Nader; Wittlieb-Weber, Carol; Pratt, Rebecca E; Alfieris, George M

    2017-01-01

    The goals following pulmonary valve replacement (PVR) are to optimize right ventricular hemodynamics and minimize the need for subsequent reoperations on the right ventricular outflow tract. We hypothesized PVR using a xenograft valved conduit would result in superior freedom from reoperation with sustained improvement in right ventricular chamber dimensions. Xenograft valved conduits placed in patients aged >16 years were reviewed from 2000 to 2010 to allow for a 5-year minimum follow-up. Preoperative, one-year, and the most recent echocardiograms quantified right ventricular chamber dimensions, corresponding Z scores, and prosthetic valve function. Magnetic resonance imaging (MRI) studies compared preoperative and follow-up right ventricular volumes. A total of 100 patients underwent PVR at 24 (19-34) years. Freedom from reintervention was 100% at 10 years. At most recent follow-up, only one patient had greater than mild pulmonary insufficiency. The one-year (17.3 ± 7.2 mm Hg; P < .01) and most recent follow-up (18.6 ± 9.8 mm Hg; P < .01) Doppler-derived right ventricular outflow tract gradients remained significantly lower than preoperative measurements (36.7 ± 27.0 mm Hg). Similarly, right ventricular basal diameter, basal longitudinal diameter, and the corresponding Z scores remained lower at one year and follow-up from preoperative measurements. From 34 MRI studies, the right ventricular end-diastolic indexed volume (161.7 ± 58.5 vs 102.9 ± 38.3; P < .01) and pulmonary regurgitant fraction (38.0% ± 15.9% vs 0.8% ± 3.3%; P < .01) were significantly lower at 7.1 ± 3.4 years compared to the preoperative levels. Use of a xenograft valved conduit for PVR results in excellent freedom from reoperation with sustained improvement in right ventricular dimensions at an intermediate-term follow-up.

  5. Should Tricuspid Annuloplasty be Performed With Pulmonary Valve Replacement for Pulmonary Regurgitation in Repaired Tetralogy of Fallot?

    PubMed

    Kurkluoglu, Mustafa; John, Anitha S; Cross, Russell; Chung, David; Yerebakan, Can; Zurakowski, David; Jonas, Richard A; Sinha, Pranava

    2015-01-01

    Indications for prophylactic tricuspid annuloplasty in patients with pulmonary regurgitation (PR) after tetralogy of Fallot (TOF) repair are unclear and often extrapolated from acquired functional tricuspid regurgitation (TR) data in adults, where despite correction of primary left heart pathology, progressive tricuspid annular dilation is noted beyond a threshold diameter >4 cm (21 mm/m(2)). We hypothesized that unlike in adult functional TR, in pure volume-overload conditions such as patients with PR after TOF, the tricuspid valve size is likely to regress after pulmonary valve replacement (PVR). A total of 43 consecutive patients who underwent PVR from 2005 until 2012 at a single institution were retrospectively reviewed. Absolute and indexed tricuspid annulus diameters (TADs), tricuspid annulus Z-scores, grade of TR along with right ventricular size, and function indices were recorded before and after PVR. Preoperative and postoperative echocardiographic data were available in all patients. A higher tricuspid valve Z-score correlated with greater TR both preoperatively (P = 0.005) and postoperatively (P = 0.02). Overall reductions in the absolute and indexed TAD and tricuspid valve Z-scores were seen postoperatively, with greater absolute as well as percentage reduction seen with larger preoperative TAD index (P = 0.007) and higher tricuspid annulus Z-scores (P = 0.06). In pure volume-overload conditions such as patients with PR after TOF, reduction in the tricuspid valve size is seen after PVR. Concomitant tricuspid annuloplasty should not be considered based on tricuspid annular dilation alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. The Midterm Outcomes of Bioprosthetic Pulmonary Valve Replacement in Children.

    PubMed

    Shinkawa, Takeshi; Lu, Chiajung K; Chipman, Carl; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki

    2015-01-01

    The purpose of this study was to assess the outcomes of bioprosthetic pulmonary valve replacement (PVR) in children. This is a retrospective review of all bioprosthetic PVR in children (≤ 20-year old) between 1992 and 2013 at a single institution. Most outcomes studied included pulmonary valve reintervention and bioprosthetic valve function. A total of 136 bioprosthetic PVRs were identified for 123 patients. The median age and body weight at the time of operation were 13.2 years and 48.4 kg. There were 1 early death and 3 late deaths during the median follow-up of 7.2 years (0-22.0 years). The actuarial transplant-free survival was 97.6% at 10 years. There were 43 bioprosthesis reinterventions with 29 reoperations and 14 catheter-based interventions. The freedom from bioprosthesis reintervention was 89.6% and 55.0% at 5 and 10 years, respectively. Echocardiographic bioprosthesis dysfunction (≥ moderate bioprosthesis insufficiency, ≥ 50 mmHg peak gradient through bioprosthesis, or bioprosthesis endocarditis with vegetation) was found in 57 bioprostheses. The freedom from bioprosthesis dysfunction was 74.0% and 32.8% at 5 and 10 years, respectively. Results from the Cox proportional hazards models showed that age had significant association with freedom from bioprosthesis reintervention and freedom from bioprosthesis dysfunction (P < 0.001 and P = 0.03), whereas bioprosthesis type had nonsignificant association with freedom from bioprosthesis dysfunction (P = 0.068). Bioprosthetic PVR in children had excellent early outcomes but rapidly deteriorating midterm outcomes. Careful and close follow-up are necessary for children with bioprosthesis in the pulmonary position. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.

    PubMed

    Park, Jun-Bean; Hwang, In-Chang; Lee, Whal; Han, Jung-Kyu; Kim, Chi-Hoon; Lee, Seung-Pyo; Yang, Han-Mo; Park, Eun-Ah; Kim, Hyung-Kwan; Chiam, Paul T L; Kim, Yong-Jin; Koo, Bon-Kwon; Sohn, Dae-Won; Ahn, Hyuk; Kang, Joon-Won; Park, Seung-Jung; Kim, Hyo-Soo

    2018-05-15

    Limited data exist regarding the impact of aortic valve calcification (AVC) eccentricity on the risk of paravalvular regurgitation (PVR) and response to balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR). We investigated the prognostic value of AVC eccentricity in predicting the risk of PVR and response to BPD in patients undergoing TAVR. We analyzed 85 patients with severe aortic stenosis who underwent self-expandable TAVR (43 women; 77.2±7.1years). AVC was quantified as the total amount of calcification (total AVC load) and as the eccentricity of calcium (EoC) using calcium volume scoring with contrast computed tomography angiography (CTA). The EoC was defined as the maximum absolute difference in calcium volume scores between 2 adjacent sectors (bi-partition method) or between sectors based on leaflets (leaflet-based method). Total AVC load and bi-partition EoC, but not leaflet-based EoC, were significant predictors for the occurrence of ≥moderate PVR, and bi-partition EoC had a better predictive value than total AVC load (area under the curve [AUC]=0.863 versus 0.760, p for difference=0.006). In multivariate analysis, bi-partition EoC was an independent predictor for the risk of ≥moderate PVR regardless of perimeter oversizing index. The greater bi-partition EoC was the only significant parameter to predict poor response to BPD (AUC=0.775, p=0.004). Pre-procedural assessment of AVC eccentricity using CTA as "bi-partition EoC" provides useful predictive information on the risk of significant PVR and response to BPD in patients undergoing TAVR with self-expandable valves. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Practical determination of aortic valve calcium volume score on contrast-enhanced computed tomography prior to transcatheter aortic valve replacement and impact on paravalvular regurgitation: Elucidating optimal threshold cutoffs.

    PubMed

    Bettinger, Nicolas; Khalique, Omar K; Krepp, Joseph M; Hamid, Nadira B; Bae, David J; Pulerwitz, Todd C; Liao, Ming; Hahn, Rebecca T; Vahl, Torsten P; Nazif, Tamim M; George, Isaac; Leon, Martin B; Einstein, Andrew J; Kodali, Susheel K

    The threshold for the optimal computed tomography (CT) number in Hounsfield Units (HU) to quantify aortic valvular calcium on contrast-enhanced scans has not been standardized. Our aim was to find the most accurate threshold to predict paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). 104 patients who underwent TAVR with the CoreValve prosthesis were studied retrospectively. Luminal attenuation (LA) in HU was measured at the level of the aortic annulus. Calcium volume score for the aortic valvular complex was measured using 6 threshold cutoffs (650 HU, 850 HU, LA × 1.25, LA × 1.5, LA+50, LA+100). Receiver-operating characteristic (ROC) analysis was performed to assess the predictive value for > mild PVR (n = 16). Multivariable analysis was performed to determine the accuracy to predict > mild PVR after adjustment for depth and perimeter oversizing. ROC analysis showed lower area under the curve (AUC) values for fixed threshold cutoffs (650 or 850 HU) compared to thresholds relative to LA. The LA+100 threshold had the highest AUC (0.81), and AUC was higher than all studied protocols, other than the LA x 1.25 and LA + 50 protocols, where the difference approached statistical significance (p = 0.05, and 0.068, respectively). Multivariable analysis showed calcium volume determined by the LAx1.25, LAx1.5, LA+50, and LA+ 100 HU protocols to independently predict PVR. Calcium volume scoring thresholds which are relative to LA are more predictive of PVR post-TAVR than those which use fixed cutoffs. A threshold of LA+100 HU had the highest predictive value. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  9. Pericardial tissue valves and Gore-Tex conduits as an alternative for right ventricular outflow tract replacement in children.

    PubMed

    Allen, Bradley S; El-Zein, Chawki; Cuneo, Betina; Cava, Joseph P; Barth, Mary Jane; Ilbawi, Michel N

    2002-09-01

    There is still no perfect conduit for reconstruction of the right ventricular outflow tract (RVOT) in children. Homografts are not always available in the appropriate size, and degenerate in a few years. This study evaluates the pericardial valve with Gore-Tex conduit as an alternative for RVOT construction. From January 1, 1993, to September 30, 1999, a pericardial tissue valve was inserted in all patients undergoing RVOT reconstruction or pulmonary valve replacement (PVR) who were large enough to accommodate a tissue valve. In patients without a native main pulmonary artery, a new technique was used to construct an RV-PA conduit out of a flat sheet of Gore-Tex, as Dacron frequently leads to stenosis. Data were collected by retrospective review, follow-up echocardiograms, and assessment by a single cardiologist. There were 48 patients, 22 undergoing a PVR alone and 26 a RV-PA valved Gore-Tex conduit. Diagnosis included tetralogy of Fallot (n = 25); truncus arteriosis (n = 9); ventricular septal defect with PA (n = 5); DORV (n = 4); D-TGA with PS (n = 2); and 1 each IAA with sub AS, VSD with PI, and PS s/p Ross procedure. Patient age ranged from 3 to 33 years and 98% were reoperations. The valve sizes ranged from 19 to 33 mm and the median hospital length of stay was 4 days. There were 2 (4.2%) perioperative and 1 (2.1%) late deaths, none related to the valve or Gore-Tex conduit. At a follow-up of 15 to 86 months (mean 43 +/- 16 months), all remaining 45 patients are New York Heart Association class I, all valves are functional, and no patient has required valve or conduit replacement or revision; more importantly, echocardiogram revealed no significant valve or conduit stenosis (mean gradient 16 +/- 8 mm Hg) and no evidence of regurgitation or structural degeneration. A pericardial tissue valve and Gore-Tex conduit provides a reliable alternative for RVOT reconstruction in pediatric patients. It is readily available, molds in the limited retrosternal space, and

  10. Is valve choice a significant determinant of paravalular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis.

    PubMed

    O'Sullivan, Katie E; Gough, Aideen; Segurado, Ricardo; Barry, Mitchel; Sugrue, Declan; Hurley, John

    2014-05-01

    Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ significantly in both structure and deployment technique. The primary objective of this study was to perform a systematic review and meta-analysis of studies identifying PVR in patients post-TAVI using Medtronic CoreValve (MCV) and Edward Sapien (ES) valves in order to identify whether a significant difference exists between valve types. The secondary objective was to identify additional factors predisposing to PVR to provide an overview of the other associated considerations. A systematic review and meta-analysis of the current literature to identify PVR rate in patients with MCV and ES valves was performed. We also sought to examine other factors predisposing to PVR. A total of 5910 patients were identified from 9 studies. PVR rates for MCV and ES were analysed. MCV was associated with a higher PVR rate of 15.75% [95% confidence interval (CI) 12.48-19.32] compared with ES 3.93% [95% CI 1.05-8.38]. We separately reviewed predisposing factors associated with PVR. A formal comparison of the MCV and ES valve leakage rates by mixed-effects meta-regression with a fixed-effect moderator variable for valve type (MCV or ES) suggested a statistically significant difference in leakage rate between the two valve types (P = 0.0002). Unfavourable anatomical and pathological factors as well as valve choice have an impact on rates of PVR. Additionally, certain anatomical features dictate valve choice. A direct comparison of all the predisposing factors at this time is not possible and will require prospective multivariate analysis. There is, however, a significant difference in the PVR rates between valves based on the published observational data available to date. The ES valve associated with a lower incidence of PVR overall; therefore, we conclude that valve choice is indeed a significant

  11. NT-proBNP and exercise capacity in adult patients with congenital heart disease and a prosthetic valve: a multicentre PROSTAVA study.

    PubMed

    Schoonbeek, R C; Pieper, P G; van Slooten, Y J; Freling, H G; Sieswerda, G T; van Dijk, A P J; Jongbloed, M R M; Post, M C; Bouma, B J; Berger, R M F; Ebels, T; van Melle, J P

    2016-11-01

    N-terminal B‑type natriuretic peptide (NT-proBNP) is an important biomarker for the detection of heart failure. Adults with congenital heart disease (ACHD) and a prosthetic heart valve are at risk for heart failure. This study aimed to determine the value of NT-proBNP in ACHD patients with a prosthetic valve and investigate its relationship with cardiac function and exercise capacity. In this multi-centre cross-sectional observational study, data regarding medical history, echocardiography, exercise testing (VO 2 peak) and laboratory blood evaluation (including NT-proBNP) were collected in ACHD patients with a single prosthetic valve (either homografts, heterografts or mechanical valves). A total of 306 ACHD patients with pulmonary valve replacement (PVR, n = 139), aortic valve replacement (n = 141), mitral valve replacement (n = 21) or tricuspid valve replacement (n = 5) were investigated. The majority of patients (77 %) were in NYHA class I or II. Elevated NT-proBNP levels (cut-off ≥125 pg/ml) were found in 50 % of the patients, with the highest levels in patients with mitral valve replacements. In this study population, NT-proBNP levels were associated with gender (p = 0.029) and VO 2 max (p < 0.001). In PVR patients, NT-proBNP levels were associated with lower VO 2 peak, also after adjustment for age, gender and age at valve replacement in a multivariate model (p = 0.015). In patients with ACHD and a prosthetic valve, elevated NT-proBNP levels are frequently observed despite preserved NYHA class. In PVR patients, a higher NT-proBNP level was associated with a lower VO 2 peak. These results may be of importance in the ongoing discussion about the timing of valve replacement in patients with CHD.

  12. Long-Term Survival and Freedom From Reoperation After Placement of a Pulmonary Xenograft Valved Conduit.

    PubMed

    Alfieris, George M; Swartz, Michael F; Lehoux, Juan; Bove, Edward L

    2016-08-01

    The optimal choice for pulmonary valve replacement (PVR) remains controversial. This study hypothesized that xenografts used for PVR would result in prolonged long-term survival and freedom from reoperation. Children and adults with congenital heart disease requiring PVR using a xenograft from 1980 to 1985 were reviewed. In all cases, the xenograft valve was either sewn or manufactured into a Dacron conduit, and the conduit was sewn to the pulmonary artery bifurcation. Clinical data were analyzed, and survival and freedom from reoperation were determined using Kaplan-Meier analysis. Twenty-four patients received a xenograft for PVR at 14.6 ± 5.6 years. Conduit size ranged from 21 to 27 mm. Most patients received a Carpentier-Edwards valved conduit (n = 17), followed by a Hancock valved conduit (n = 5) and an Ionescu-Shiley valve sewn into a Dacron graft (n = 2). No perioperative deaths occurred. Reoperation was required mainly for pulmonary stenosis (72.7%), followed by pulmonary insufficiency (18.2%), or both stenosis and insufficiency (9%). Freedom from reoperation was 90%, 56%, 43%, and 14% at 10, 20, 25, and 30 years, respectively. At most recent follow-up the was only death, which was related to severe biventricular failure 25 years after conduit implant. PVR using a xenograft valved conduit results in prolonged freedom from reoperation and excellent long-term survival. These data, which provide long-term follow-up information on xenograft valves after PVR. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation

    PubMed Central

    Spina, Roberto; Anthony, Chris; Muller, David WM

    2015-01-01

    Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674

  14. Mechanical valve replacement in congenital heart disease.

    PubMed

    Fiane, A E; Lindberg, H L; Saatvedt, K; Svennevig, J L

    1996-05-01

    Mechanical valves are the prosthesis of choice in valve replacement in children. However, the problem of somatic growth leading to patient-valve mismatch remains present, and the appropriate anticoagulation regimen remains controversial. We present our experience of valve replacement in a young population over 20 years. Between 1972 and 1992, 48 patients (34 males and 14 females), mean age 11.2 years (range 0.4-27.4 years), underwent mechanical valve replacement at our institution. Aortic valve replacement was performed in 28 patients (58.3%), mitral valve replacement in 13 (27.1%), tricuspid valve replacement in six (12.5%) and pulmonary valve replacement in one patient (2.1%). The prostheses used were: St. Jude Medical (n = 2), Björk-Shiley (n = 14), Medtronic Hall (n = 16), Duromedics (n = 2) and CarboMedics (n = 14). Early mortality was 14.3%, 10.7% for aortic valve replacement and 30.8% for mitral valve replacement. Mean follow up for all patients was 8.3 years (range 0-22 years), with a total of 398 patient-years. Seven patients died during the follow up (17.1%). Survival after 10 years, including operative mortality, was 81% for aortic valve replacement, 33% for mitral valve replacement, 83% for tricuspid valve replacement and 100% for pulmonary valve replacement. All patients were anticoagulated with warfarin. In eight patients (16.7%) an antiplatelet drug (aspirin or dipyridamole) was added. Major events included paravalvular leak in six patients (1.5%/pty), valve thrombosis in five (mitral position in two, tricuspid in three) (1.3%/pty) and endocarditis in one patient (0.3%/pty). Minor thromboembolic events occurred in three patients (0.8%/pty) and minor hemorrhagic events in three (0.8%/pty). No patients developed hemolytic anemia and there was no case of structural failure. In our experience, mechanical prostheses in congenital heart disease were associated with significant morbidity and mortality, however long term survival after aortic valve

  15. Decellularized fresh homografts for pulmonary valve replacement: a decade of clinical experience†

    PubMed Central

    Sarikouch, Samir; Horke, Alexander; Tudorache, Igor; Beerbaum, Philipp; Westhoff-Bleck, Mechthild; Boethig, Dietmar; Repin, Oleg; Maniuc, Liviu; Ciubotaru, Anatol; Haverich, Axel; Cebotari, Serghei

    2016-01-01

    OBJECTIVES Decellularized homografts have shown auspicious early results when used for pulmonary valve replacement (PVR) in congenital heart disease. The first clinical application in children was performed in 2002, initially using pre-seeding with endogenous progenitor cells. Since 2005, only non-seeded, fresh decellularized allografts have been implanted after spontaneous recellularization was observed by several groups. METHODS A matched comparison of decellularized fresh pulmonary homografts (DPHs) implanted for PVR with cryopreserved pulmonary homografts (CHs) and bovine jugular vein conduits (BJVs) was conducted. Patients’ age at implantation, the type of congenital malformation, number of previous cardiac operations and number of previous PVRs were considered for matching purposes, using an updated contemporary registry of right ventricular outflow tract conduits (2300 included conduits, >12 000 patient-years). RESULTS A total of 131 DPHs were implanted for PVR in the period from January 2005 to September 2015. Of the 131, 38 were implanted within prospective trials on DPH from October 2014 onwards and were therefore not analysed within this study. A total of 93 DPH patients (58 males, 35 females) formed the study cohort and were matched to 93 CH and 93 BJV patients. The mean age at DPH implantation was 15.8 ± 10.21 years (CH 15.9 ± 10.4, BJV 15.6 ± 9.9) and the mean DPH diameter was 23.9 mm (CH 23.3 ± 3.6, BJV 19.9 ± 2.9). There was 100% follow-up for DPH, including 905 examinations with a mean follow-up of 4.59 ± 2.76 years (CH 7.4 ± 5.8, BJV 6.4 ± 3.8), amounting to 427.27 patient-years in total (CH 678.3, BJV 553.0). Tetralogy-of-Fallot was the most frequent malformation (DPH 50.5%, CH 54.8%, BJV 68.8%). At 10 years, the rate of freedom of explantation was 100% for DPH, 84.2% for CH (P = 0.01) and 84.3% for BJV (P= 0.01); the rate of freedom from explantation and peak trans-conduit gradient ≥50 mmHg was 86% for DPH, 64% for CH (n.s.) and 49

  16. Valve Repair or Replacement

    MedlinePlus

    ... called anticoagulants) for the rest of their lives. Biological valves are made from animal tissue (called a ... for valve replacement (called an autograft). Patients with biological valves usually do not need to take blood- ...

  17. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    PubMed

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  18. 21 CFR 870.3925 - Replacement heart valve.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...

  19. 21 CFR 870.3925 - Replacement heart valve.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...

  20. 21 CFR 870.3925 - Replacement heart valve.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...

  1. 21 CFR 870.3925 - Replacement heart valve.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...

  2. 21 CFR 870.3925 - Replacement heart valve.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Replacement heart valve. 870.3925 Section 870.3925...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3925 Replacement heart valve. (a) Identification. A replacement heart valve is a device intended to perform the function of any...

  3. Options for Heart Valve Replacement

    MedlinePlus

    ... which may include human or animal donor tissue) Ross Procedure — “Borrowing” your healthy valve and moving it ... Considerations for Surgery Medications Valve Repair Valve Replacement - Ross Procedure - Newer Surgery Options - What is TAVR? - Types ...

  4. Valve assembly having remotely replaceable bearings

    DOEpatents

    Johnson, Evan R.; Tanner, David E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings.

  5. [Longterm results of mitral valve replacement (author's transl)].

    PubMed

    Erhard, W; Reichmann, M; Delius, W; Sebening, H; Herrmann, G

    1977-04-22

    210 patients were followed up by the actuary method for over 5 years after isolated mitral valve replacement or a double valve replacement. After isolated valve replacement the one month survival including the operative mortality was 92+/-2%. The survival after one year was 83+/-3% and after 5 years 66+/-7%. The five year survival of patients in preoperative class III (according to the NYHA) was 73+/-8% and of class IV 57+/-8% (P less than or equal to 0.1). A comparison of valve replacements for pure mitral stenosis or mitral insufficiency showed no statistically significant differences. In the 37 patients who had a double valve replacement the survival risk was not increased in comparison with those patients who had had a single valve replacement. Age above 45 years and a preoperative markedly raised pulmonary arteriolar resistance reduced the chances of survival.

  6. Aortic valve replacement for papillary fibroelastoma.

    PubMed

    Arikan, Ali Ahmet; Omay, Oğuz; Aydın, Fatih; Kanko, Muhip; Gür, Sibel; Derviş, Emir; Yılmaz, Cansu Eda; Müezzinoğlu, Bahar

    2017-06-01

    Surgery is indicated for symptomatic patients with papillary fibroelastomas (PFE) on the aortic valve. The valve is commonly spared during tumor excision. Rarely, aortic valve replacement (AVR) is needed. We present a case requiring AVR for an aortic valve PFE and review the literature to determine the risk factors for failure of aortic valve-sparing techniques in patients with PFE. © 2017 Wiley Periodicals, Inc.

  7. "Pulmonary valve replacement diminishes the presence of restrictive physiology and reduces atrial volumes": a prospective study in Tetralogy of Fallot patients.

    PubMed

    Pijuan-Domenech, Antonia; Pineda, Victor; Castro, Miguel Angel; Sureda-Barbosa, Carlos; Ribera, Aida; Cruz, Luz M; Ferreira-Gonzalez, Ignacio; Dos-Subirà, Laura; Subirana-Domènech, Teresa; Garcia-Dorado, David; Casaldàliga-Ferrer, Jaume

    2014-11-15

    Pulmonary valve replacement (PVR) reduces right ventricular (RV) volumes in the setting of long-term pulmonary regurgitation after Tetralogy of Fallot (ToF) repair; however, little is known of its effect on RV diastolic function. Right atrial volumes may reflect the burden of RV diastolic dysfunction. The objective of this paper is to evaluate the clinical, echocardiographic, biochemical and cardiac magnetic resonance (CMR) variables, focusing particularly on right atrial response and right ventricular diastolic function prior to and after elective PVR in adult patients with ToF. This prospective study was conducted from January 2009 to April 2013 in consecutive patients > 18 years of age who had undergone ToF repair in childhood and were accepted for elective PVR. Twenty patients (mean age: 35 years; 70% men) agreed to enter the study. PVR was performed with a bioporcine prosthesis. Concomitant RV reduction was performed in all cases when technically possible. Pulmonary end-diastolic forward flow (EDFF) decreased significantly from 5.4 ml/m(2) to 0.3 ml/m(2) (p < 0.00001), and right atrial four-chamber echocardiographic measurements and volumes by 25% (p = 0.0024): mean indexed diastolic/systolic atrial volumes prior to surgery were 43 ml/m(2) (SD+/-4.6)/63 ml/m(2) (SD+/-5.5), and dropped to 33 ml/m(2) (SD+/-3)/46 ml/m(2) (SD+/-2.55) post-surgery. All patients presented right ventricular diastolic and systolic volume reductions, with a mean volume reduction of 35% (p < 0.00001). Right ventricular diastolic dysfunction was common in a population of severely dilated RV patients long term after ToF repair. Right ventricular diastolic parameters improved as did right atrial volumes in keeping with the known reduction in RV volumes, after PVR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. Mitral valve replacement with the Hancock stabilized glutaraldehyde valve. Clinical and laboratory evaluation.

    PubMed

    Buch, W S; Pipkin, R D; Hancock, W D; Fogarty, T J

    1975-11-01

    From March 1971 through April 1975, one hundred twenty patients underwent mitral valve replacement with a Hancock "stabilized glutaraldehyde process" porcine aortic xenograft. A simultaneous canine experimental series was also carried out. In the clinical series, the early mortality was 8.3%. Actuarial analyses of all patients predicts survival at two years of 81.0% and at four years of 70.0%. The predicted survival for patients without coronary disease or prior prosthetic valve replacement is 87.5% at two years and 77.5% at four years. There were four thromboembolic episodes, a rate of 2.4% per patient-year. None were fatal. No valve failure were noted. Histologic examination and shrink temperature analysis of recovered valves show excellent tissue preservation at 40 months. The data indicate that the Hancock valve is durable, enjoys a low incidence of thromboembolism, and may be the valve of choice for mitral valve replacement.

  9. Four-year durability of clinical and haemodynamic outcomes of transcatheter aortic valve implantation with the self-expanding CoreValve.

    PubMed

    Gulino, Simona; Barbanti, Marco; Deste, Wanda; Immè, Sebastiano; Aruta, Patrizia; Bottari, Vera; Benvenuto, Emanuele; Tamburino, Claudia; Di Landro, Alessio; Liberto, Daria; Santonoceto, Letizia; Sicuso, Rita; Di Stefano, Daniele; Todaro, Denise; Di Simone, Emanuela; Indelicato, Antonino; Giannazzo, Daniela; Sgroi, Carmelo; Tamburino, Corrado

    2016-10-10

    Long-term data on the durability of currently available transcatheter heart valves are limited. We sought to assess four-year clinical and echocardiographic outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis. Between June 2007 and February 2014, 450 consecutive patients with symptomatic severe aortic stenosis underwent TAVI in our institution. For the purposes of this study, we included only those patients undergoing successful TAVI with the CoreValve prosthesis who had a minimum follow-up of four years (n=125). Survival rates at one, two, three and four years were 83.2, 76.8, 73.6 and 66.3%, respectively. Aortic regurgitation was a common finding after the procedure, especially due to paravalvular regurgitation (PVR), which was observed in the majority of patients (71.5%), mostly mild (52.0%). Progression from mild acute PVR to moderate PVR at four-year follow-up was reported in three patients. No cases of severe PVR were observed. Prosthetic valve failure was reported in four patients (3.2%). Our study demonstrates that favourable outcomes after successful TAVI are associated with sustained clinical and functional cardiovascular benefits up to four-year follow-up. Signs of moderate prosthetic valve failure are present only in a small percentage of patients.

  10. Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.

    PubMed

    Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V

    1992-02-01

    From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and

  11. Fine Mapping of the Dominant Potyvirus Resistance Gene Pvr7 Reveals a Relationship with Pvr4 in Capsicum annuum.

    PubMed

    Venkatesh, Jelli; An, Jeongtak; Kang, Won-Hee; Jahn, Molly; Kang, Byoung-Cheorl

    2018-01-01

    Pepper mottle virus (PepMoV) is the most common potyvirus infection of pepper plants and causes significant yield losses. The Pvr7 gene from Capsicum chinense PI159236 and the Pvr4 gene from C. annuum CM334 both have been reported to confer dominant resistance to PepMoV. The Pvr7 locus conferring resistance to PepMoV in C. annuum '9093' was previously mapped to chromosome 10. To develop a high-resolution map of the Pvr7 locus in 9093, we constructed an intraspecific F 2 mapping population consisting of 916 individuals by crossing PepMoV-resistant C. annuum '9093' and the PepMoV-susceptible C. annuum 'Jeju'. To delimit the Pvr7 target region, single-nucleotide polymorphism (SNP) markers derived from the Pvr4 region were used for genotyping the F 2 population. Molecular mapping delimited the Pvr7 locus to a physical interval of 258 kb, which was the same region as Pvr4 on chromosome 10. Three SNP markers derived from Pvr4 mapping perfectly cosegregated with PepMoV resistance. Sequencing analyses of the Pvr7 flanking markers and the Pvr4-specific gene indicated that Pvr7 and Pvr4 are the same gene. Resistance spectrum analysis of 9093 against pepper potyviruses showed that 9093 has a resistance spectrum similar to that of cultivar CM334. These combined results demonstrate that, unlike previously thought, the dominant PepMoV resistance in 9093 could be derived from C. annuum 'CM334', and that Pvr4 and Pvr7 should be considered as the same locus.

  12. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    PubMed

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p < 0.0001), tricuspid valve regurgitation (mean 2.33 vs 1.3, p < 0.0001), and in right ventricular dilation, volume, and area. There was no difference in the degree of tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve

  13. Transcatheter Mitral Valve Replacement for Native and Failed Bioprosthetic Mitral Valves

    PubMed Central

    Sarkar, Kunal; Reardon, Michael J.; Little, Stephen H.; Barker, Colin M.; Kleiman, Neal S.

    2017-01-01

    Transcatheter mitral valve replacement (TMVR) is a novel approach for treatment of severe mitral regurgitation. A number of TMVR devices are currently undergoing feasibility trials using both transseptal and transapical routes for device delivery. Overall experience worldwide is limited to fewer than 200 cases. At present, the 30-day mortality exceeds 30% and is attributable to both patient- and device-related factors. TMVR has been successfully used to treat patients with degenerative mitral stenosis (DMS) as well as failed mitral bioprosthesis and mitral repair using transcatheter mitral valve-in-valve (TMViV)/valve-in-ring (ViR) repair. These patients are currently treated with devices designed for transcatheter aortic valve replacement. Multicenter registries have been initiated to collect outcomes data on patients currently undergoing TMViV/ViR and TMVR for DMS and have confirmed the feasibility of TMVR in these patients. However, the high periprocedural and 30-day event rates underscore the need for further improvements in device design and multicenter randomized studies to delineate the role of these technologies in patients with mitral valve disease. PMID:29743999

  14. Valve replacement in children: a challenge for a whole life.

    PubMed

    Henaine, Roland; Roubertie, François; Vergnat, Mathieu; Ninet, Jean

    2012-10-01

    Valvular pathology in infants and children poses numerous challenges to the paediatric cardiac surgeon. Without question, valvular repair is the goal of intervention because restoration of valvular anatomy and physiology using native tissue allows for growth and a potentially better long-term outcome. When reconstruction fails or is not feasible, valve replacement becomes inevitable. Which valve for which position is controversial. Homograft and bioprosthetic valves achieve superior haemodynamic results initially but at the cost of accelerated degeneration. Small patient size and the risk of thromboembolism limit the usefulness of mechanical valves, and somatic outgrowth is an universal problem with all available prostheses. The goal of this article is to address valve replacement options for all four valve positions within the paediatric population. We review current literature and our practice to support our preferences. To summarize, a multitude of opinions and surgical experiences exist. Today, the valve choices that seem without controversy are bioprosthetic replacement of the tricuspid valve and Ross or Ross-Konno procedures when necessary for the aortic valve. On the other hand, bioprostheses may be implanted when annular pulmonary diameter is adequate; if not or in case of right ventricular outflow tract discontinuity, it is better to use a pulmonary homograft with the Ross procedure. Otherwise, a valved conduit. Mitral valve replacement remains the most problematic; the mechanical prosthesis must be placed in the annular position, avoiding oversizing. Future advances with tissue-engineered heart valves for all positions and new anticoagulants may change the landscape for valve replacement in the paediatric population. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  15. Anesthetic Considerations for Transcatheter Pulmonary Valve Replacement.

    PubMed

    Gregory, Stephen H; Zoller, Jonathan K; Shahanavaz, Shabana; Chilson, Kelly L; Ridley, Clare H

    2018-02-01

    The introduction of transcatheter therapy for valvular heart disease has revolutionized the care of patients with valvular disorders. Pathologic regurgitation or stenosis of the pulmonary valve, right ventricular outflow tract, or a right ventricle-to-pulmonary artery conduit represent emerging indications for transcatheter therapy. To date, minimal literature exists detailing the anesthetic management of patients undergoing transcatheter pulmonary valve replacement. In this review, the pathophysiology and indications for transcatheter pulmonary valve replacement and possible complications unique to this procedure are reviewed. Anesthetic management, including preoperative assessment, intraoperative considerations, and early postoperative monitoring, are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    PubMed

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  17. Patient-Specific MRI-Based Right Ventricle Models Using Different Zero-Load Diastole and Systole Geometries for Better Cardiac Stress and Strain Calculations and Pulmonary Valve Replacement Surgical Outcome Predictions.

    PubMed

    Tang, Dalin; Del Nido, Pedro J; Yang, Chun; Zuo, Heng; Huang, Xueying; Rathod, Rahul H; Gooty, Vasu; Tang, Alexander; Wu, Zheyang; Billiar, Kristen L; Geva, Tal

    2016-01-01

    Accurate calculation of ventricular stress and strain is critical for cardiovascular investigations. Sarcomere shortening in active contraction leads to change of ventricular zero-stress configurations during the cardiac cycle. A new model using different zero-load diastole and systole geometries was introduced to provide more accurate cardiac stress/strain calculations with potential to predict post pulmonary valve replacement (PVR) surgical outcome. Cardiac magnetic resonance (CMR) data were obtained from 16 patients with repaired tetralogy of Fallot prior to and 6 months after pulmonary valve replacement (8 male, 8 female, mean age 34.5 years). Patients were divided into Group 1 (n = 8) with better post PVR outcome and Group 2 (n = 8) with worse post PVR outcome based on their change in RV ejection fraction (EF). CMR-based patient-specific computational RV/LV models using one zero-load geometry (1G model) and two zero-load geometries (diastole and systole, 2G model) were constructed and RV wall thickness, volume, circumferential and longitudinal curvatures, mechanical stress and strain were obtained for analysis. Pairwise T-test and Linear Mixed Effect (LME) model were used to determine if the differences from the 1G and 2G models were statistically significant, with the dependence of the pair-wise observations and the patient-slice clustering effects being taken into consideration. For group comparisons, continuous variables (RV volumes, WT, C- and L- curvatures, and stress and strain values) were summarized as mean ± SD and compared between the outcome groups by using an unpaired Student t-test. Logistic regression analysis was used to identify potential morphological and mechanical predictors for post PVR surgical outcome. Based on results from the 16 patients, mean begin-ejection stress and strain from the 2G model were 28% and 40% higher than that from the 1G model, respectively. Using the 2G model results, RV EF changes correlated negatively with stress

  18. Will Catheter Interventions Replace Surgery for Valve Abnormalities?

    PubMed Central

    O’Byrne, Michael L; Gillespie, Matthew J

    2015-01-01

    Purpose of Review Catheter-based valve technologies have evolved rapidly over the last decade. Transcatheter aortic valve replacement (TAVR) has become a routine procedure in high-risk adult patients with calcific aortic stenosis. In patients with congenital heart disease (CHD), transcatheter pulmonary valve replacement represents a transformative technology for right ventricular outflow tract dysfunction with the potential to expand to other indications. This review aims to summarize 1) the current state of the art for transcatheter valve replacement (TVR) in CHD, 2) the expanding indications for TVR, and 3) the technological obstacles to optimizing TVR. Recent findings Multiple case series have demonstrated that TVR with the Melody transcatheter pulmonary valve in properly selected patients is safe, effective, and durable in short-term follow-up. The Sapien transcatheter heart valve represents an alternative device with similar safety and efficacy in limited studies. Innovative use of current valves has demonstrated the flexibility of TVR, while highlighting the need for devices to address the broad range of post-operative anatomies either with a single device or strategies to prepare the outflow tract for subsequent device deployment. Summary The potential of TVR has not been fully realized, but holds promise in treatment of CHD. PMID:24281347

  19. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    PubMed Central

    2012-01-01

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function. PMID:22747790

  20. Should patients with Björk-Shiley valves undergo prophylactic replacement?

    PubMed

    Birkmeyer, J D; Marrin, C A; O'Connor, G T

    1992-08-29

    About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that

  1. Mitral valve replacement with preservation of the subvalvular apparatus.

    PubMed

    Reardon, M J; David, T E

    1999-03-01

    The introduction of the Starr-Edwards valve allowed complete replacement of diseased left-sided heart valves. With improved cardiopulmonary bypass, myocardial protection, and surgical techniques the mortality rate from aortic valve replacement decreased substantially, whereas the mortality rate from mitral valve replacement remained high, largely because of low cardiac output syndrome. Increasing use of mitral valve repair techniques resulted in a marked decrease in short-term and long-term morbidity and mortality when treating patients with mitral regurgitation. Some believed that this resulted from maintenance of the mitral annular papillary muscle continuity during mitral valve repair. Subsequent experimental and clinical studies have validated the positive short-term and long-term effects of maintaining the integrity of the mitral valve subvalvular apparatus. This article considers the history of the clinical use of preservation of the subvalvular apparatus, the physiologic studies examining this concept, and the clinical data available on its use. It also examines the following: 1) mitral stenosis versus mitral regurgitation and the preservation of the subvalvular apparatus; 2) whether the anterior, posterior, or both areas of the subvalvular apparatus should be preserved; and 3) the surgical techniques for the preservation of the subvalvular apparatus and valve implantation.

  2. Cost-effectiveness of homograft heart valve replacement surgery: an introductory study.

    PubMed

    Yaghoubi, Mohsen; Aghayan, Hamid Reza; Arjmand, Babak; Emami-Razavi, Seyed Hassan

    2011-05-01

    The clinical effectiveness of heart valve replacement surgery has been well documented. Mechanical and homograft valves are used routinely for replacement of damaged heart valves. Homograft valves are produced in our country but we import the mechanical valves. To our knowledge the cost-effectiveness of homograft valve has not been assessed. The objective of the present study was to compare the cost-effectiveness of homograft valve replacement with mechanical valve replacement surgery. Our samples were selected from 200 patients that underwent homograft and mechanical heart valve replacement surgery in Imam-Khomeini hospital (2000-2005). In each group we enrolled 30 patients. Quality of life was measured using the SF-36 questionnaire and utility was measured in quality-adjusted life years (QALYs). For each group we calculated the price of heart valve and hospitalization charges. Finally the cost-effectiveness of each treatment modalities were summarized as costs per QALYs gained. Forty male and twenty female participated in the study. The mean score of quality of life was 66.06 (SD = 9.22) in homograft group and 57.85 (SD = 11.30) in mechanical group (P < 0.05). The mean QALYs gained in homograft group was 0.67 more than mechanical group. The incremental cost-effectiveness ratio (ICER) revealed a cost savings of 1,067 US$ for each QALY gained in homograft group. Despite limitation of this introductory study, we concluded that homograft valve replacement was more effective and less expensive than mechanical valve. These findings can encourage healthcare managers and policy makers to support the production of homograft valves and allocate more recourse for developing such activities.

  3. Evaluation of mitral valve replacement anchoring in a phantom

    NASA Astrophysics Data System (ADS)

    McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.

    2012-02-01

    Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.

  4. [Transcatheter aortic valve replacement].

    PubMed

    Sawa, Yoshiki

    2014-07-01

    While transcatheter aortic valve replacement( TAVR) has spread rapidly all over the world for highrisk patients with severe aortic stenosis (AS), SAPIEN XT was approved in Japan in October 2013. Since that, approximately 400 TAVR cases were performed in Japan. In our institute, we have performed 164 cases since first case in Japan in 2009 and have achieved satisfactory early results(30-day mortality:1.2%). At the same time, however, simultaneously various TAVR-related complications including a paravalvular leak, stroke, vascular complications, and coronary obstruction were observed. A reduction in the incidence and severity of these complications had led technical improvements in various new devices(2nd generation TAVR device such as the SAPIEN 3, ACURATE, and JenaValve) and in implantation techniques including repositioning/recapturing features, paravalvular sealing technologies, and prevention of coronary obstruction. Furthermore, there is also increasing experience with special indications for TAVR such as pure aortic valve insufficiency or valve-in-valve techniques. Currently, an increasing number of publications of midterm results demonstrate good prosthetic valve function and durability, with good quality of life and low morbidity after TAVR. There are also some randomized trials such as PARTNER 2 or SURTAVI to investigate potential benefits of TAVR for intermediate-risk patients. These improvements in the TAVR devices promises the expansion of TAVR towards the treatment of lower-risk patients in the near future.

  5. Early Outcomes for Valve-in-valve Transcatheter Aortic Valve Replacement in Degenerative Freestyle Bioprostheses.

    PubMed

    Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William

    2017-11-20

    Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Aortic valve replacement with the Biocor PSB stentless xenograft.

    PubMed

    Bertolini, P; Luciani, G B; Vecchi, B; Pugliese, P; Mazzucco, A

    1998-08-01

    The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and

  7. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  8. Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?

    PubMed

    Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-11-01

    Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.

  9. Aorta-atria-septum combined incision for aortic valve re-replacement

    PubMed Central

    Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong

    2018-01-01

    This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170

  10. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  11. Factors influencing mortality after bioprosthetic valve replacement; a midterm outcome.

    PubMed

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population.

  12. Transcatheter aortic-valve replacement with a self-expanding prosthesis.

    PubMed

    Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K

    2014-05-08

    We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).

  13. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    PubMed

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Complementary role of cardiac CT in the assessment of aortic valve replacement dysfunction

    PubMed Central

    Moss, Alastair J; Dweck, Marc R; Dreisbach, John G; Williams, Michelle C; Mak, Sze Mun; Cartlidge, Timothy; Nicol, Edward D; Morgan-Hughes, Gareth J

    2016-01-01

    Aortic valve replacement is the second most common cardiothoracic procedure in the UK. With an ageing population, there are an increasing number of patients with prosthetic valves that require follow-up. Imaging of prosthetic valves is challenging with conventional echocardiographic techniques making early detection of valve dysfunction or complications difficult. CT has recently emerged as a complementary approach offering excellent spatial resolution and the ability to identify a range of aortic valve replacement complications including structural valve dysfunction, thrombus development, pannus formation and prosthetic valve infective endocarditis. This review discusses each and how CT might be incorporated into a multimodal cardiovascular imaging pathway for the assessment of aortic valve replacements and in guiding clinical management. PMID:27843568

  15. Aortic valve replacement for Libman-Sacks endocarditis

    PubMed Central

    Keenan, Jack B; Janardhanan, Rajesh; Larsen, Brandon T; Khalpey, Zain

    2016-01-01

    A 24-year-old man with systemic lupus erythematosus and antiphospholipid syndrome complicated by lupus nephritis presented with acute limb ischaemia secondary to an embolus. Following embolectomy, the patient underwent a transthoracic echocardiogram which revealed a large vegetation on all three cusps of the aortic valve. The patient was taken for an urgent aortic valve replacement with a mechanical valve. Cultures of one cusp remained sterile. Histopathological examination of the remaining two cusps revealed sterile fibrin-rich thrombotic vegetations characteristic of non-bacterial thrombotic endocarditis. PMID:27702929

  16. A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in "real-world" patients with aortic stenosis and intermediate- to high-risk profile.

    PubMed

    Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry

    2015-12-01

    We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (P< .001) and peripheral vascular complications occurred in 0% of surgicalaortic valve replacement vs 0% of sutureless vs 9.8% transcatheter aortic valve replacement (P< .001). At 24-month follow-up, overall survival (surgical aortic valve replacement = 91.3% ± 2.4% vs sutureless = 94.9% ± 2.1% vs transcatheter aortic valve replacement = 79.5% ± 4.3%; P < .001) and survival free from the composite end point of major adverse cardiovascular events and periprosthetic regurgitation were significantly

  17. Risk Factors for Prosthetic Pulmonary Valve Failure in Patients With Congenital Heart Disease.

    PubMed

    Oliver, Jose Maria; Garcia-Hamilton, Diego; Gonzalez, Ana Elvira; Ruiz-Cantador, Jose; Sanchez-Recalde, Angel; Polo, Maria Luz; Aroca, Angel

    2015-10-15

    The incidence and risk factors for prosthetic pulmonary valve failure (PPVF) should be considered when determining optimal timing for pulmonary valve replacement (PVR) in asymptomatic patients with congenital heart disease (CHD). The cumulative freedom for reintervention due to PPVF after 146 PVR in 114 patients with CHD was analyzed. Six potential risk factors (underlying cardiac defect, history of palliative procedures, number of previous cardiac interventions, hemodynamic indication for PVR, type of intervention, and age at intervention) were analyzed using Cox proportional hazard modeling. Receiver operating characteristic (ROC) curves were used for discrimination. Internal validation in patients with tetralogy of Fallot was also performed. Median age at intervention was 23 years. There were 60 reinterventions due to PPVF (41%). Median event-free survival was 14 years (95% confidence interval [CI] 12 to 16 years). The only independent risk factor was the age at intervention (hazard ratio [HR] 0.93, 95% CI 0.90 to 0.97; p = 0.001; area under the ROC curve 0.95, 95% CI 0.92 to 0.98; p <0.001). The best cut-off point was 20.5 years. Freedom from reintervention for PPVF 15 years after surgery was 70% when it was performed at age >20.5 years compared with 33% when age at intervention was <20.5 years (p = 0.004). Internal validation in 102 PVR in patient cohort with tetralogy of Fallot (ROC area 0.98, 95% CI 0.96 to 1.0; p <0.001) was excellent. In conclusion, age at intervention is the main risk factor of reintervention for PPVF. The risk of reintervention is 2-fold when PVR is performed before the age of 20.5 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome

    PubMed Central

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Methods: Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Results: Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Conclusion: Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population. PMID:24404348

  19. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement.

    PubMed

    Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J

    2016-01-05

    Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of

  20. Aortic valve replacement for Libman-Sacks endocarditis.

    PubMed

    Keenan, Jack B; Janardhanan, Rajesh; Larsen, Brandon T; Khalpey, Zain

    2016-10-04

    A 24-year-old man with systemic lupus erythematosus and antiphospholipid syndrome complicated by lupus nephritis presented with acute limb ischaemia secondary to an embolus. Following embolectomy, the patient underwent a transthoracic echocardiogram which revealed a large vegetation on all three cusps of the aortic valve. The patient was taken for an urgent aortic valve replacement with a mechanical valve. Cultures of one cusp remained sterile. Histopathological examination of the remaining two cusps revealed sterile fibrin-rich thrombotic vegetations characteristic of non-bacterial thrombotic endocarditis. 2016 BMJ Publishing Group Ltd.

  1. Valve Repair Is Superior to Replacement in Most Patients With Coexisting Degenerative Mitral Valve and Coronary Artery Diseases.

    PubMed

    Javadikasgari, Hoda; Gillinov, A Marc; Idrees, Jay J; Mihaljevic, Tomislav; Suri, Rakesh M; Raza, Sajjad; Houghtaling, Penny L; Svensson, Lars G; Navia, José L; Mick, Stephanie L; Desai, Milind Y; Sabik, Joseph F; Blackstone, Eugene H

    2017-06-01

    For mitral regurgitation (MR) from degenerative mitral disease in patients with coexisting coronary artery disease, the appropriate surgical strategy remains controversial. From 1985 to 2011, 1,071 adults (age 70 ± 9.3 years, 77% men) underwent combined coronary artery bypass grafting and either mitral valve repair (n = 872, 81%) or replacement (n=199, 19%) for degenerative MR. Propensity matching (177 patient pairs, 89% of possible matches) was used to compare early outcomes and time-related recurrence of MR after mitral valve repair, mitral valve reoperation, and mortality. Risk factors for death were identified with multivariable, multiphase hazard-function analysis. Patients undergoing valve replacement were older, with more valve calcification and a higher prevalence of preoperative atrial fibrillation and heart failure (all p < .0001). Among matched pairs, mitral replacement versus repair was associated with higher hospital mortality (5.0% vs 1.0%, p = .0001) and more postoperative renal failure (7.0% vs 3.2%, p = .01), reexplorations for bleeding (6.0% vs 3.1%, p = .05), and respiratory failure (14% vs 4.7%, p < .0001). Of matched patients undergoing repair, 18% had MR above 3+ by 5 years. Mitral valve durability was similar between matched groups, but survival at 15 years was 18% after replacement versus 52% after repair. Nomograms from the multivariable equation revealed that in 94% of cases, 10-year survival was calculated to be higher after repair than after replacement. In patients with coexisting degenerative mitral valve and coronary artery diseases, mitral valve repair is expected to confer a long-term survival advantage over replacement despite some recurrence of MR. When feasible, it is the procedure of choice for these patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Intraoperative echocardiographic detection of regurgitant jets after valve replacement

    NASA Technical Reports Server (NTRS)

    Morehead, A. J.; Firstenberg, M. S.; Shiota, T.; Qin, J.; Armstrong, G.; Cosgrove, D. M. 3rd; Thomas, J. D.

    2000-01-01

    BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.

  3. Acquired discrete subaortic stenosis late after mitral valve replacement.

    PubMed

    Mohan, Jagdish C; Shukla, Madhu; Mohan, Vishwas; Sethi, Arvind

    2016-09-01

    Although acquired left ventricular outflow obstruction has been reported in a variety of conditions, there are scant reports of its occurrence following mitral valve replacement (MVR). This study describes two female patients, who developed severe discrete subaortic stenosis, five years following MVR. In both cases, the mitral valve was replaced by a porcine Carpentier-Edwards 27-mm bioprosthesis with preservation of mitral valve leaflets. The risk of very late left ventricular outflow tract obstruction after bio-prosthetic MVR with preservation of subvalvular apparatus needs to be kept in mind in symptomatic patients. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  4. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    PubMed

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  5. One-year outcomes after rapid-deployment aortic valve replacement.

    PubMed

    Young, Christopher; Laufer, Günther; Kocher, Alfred; Solinas, Marco; Alamanni, Francesco; Polvani, Gianluca; Podesser, Bruno K; Aramendi, Jose Ignacio; Arribas, Jose; Bouchot, Olivier; Livi, Ugolino; Massetti, Massimo; Terp, Kim; Giot, Christophe; Glauber, Mattia

    2018-02-01

    The goals of rapid-deployment aortic valve replacement include facilitation of minimally invasive surgery and reduced aortic crossclamp time. We report the short-term outcomes of a series of 493 patients undergoing rapid-deployment aortic valve replacement with the EDWARDS INTUITY valve system (Edwards Lifesciences, LLC, Irvine, Calif). Assessing Standard oF Care and Clinical Outcomes UsiNg the EDWARDS INTUITY VAlve SysTem in a European multI-center, Active, pOst-market surveillaNce Study was a prospective, multicenter (n = 26) European registry designed to evaluate the safety and performance of the valve system. During rapid-deployment aortic valve replacement, device technical success and crossclamp time were assessed. Procedural outcomes, hemodynamic performance, and various adverse events and clinical outcomes were evaluated up to 2 years. Between 2012 and 2014, 493 of 517 enrolled patients successfully received implants with the study valve (95.4% technical success). Mean crossclamp times for 163 full sternotomies, 128 mini-upper sternotomies, and 36 right anterior thoracotomies isolated aortic valve replacements were 47.3, 52.0, and 73.3 minutes, respectively. Mean follow-up was 1.8 years, with 870 total patient-years of follow-up. Mean effective orifice area increased from 0.72 (baseline) to 1.88 cm 2 , and mean pressure gradient decreased from 47.6 to 9.6 mm Hg (1 year). Mean effective orifice area index increased (0.39-1.01 cm 2 /m 2 ), and 28 of 287 patients (9.8%) exhibited severe prosthesis-patient mismatch at 1 year. After 1 year, 68.1% and 21.7% of patients were in New York Heart Association class I and II, respectively. Freedom from death, major bleeding, major perivalvular leak, reoperation, and device explant at 1 year were 0.935, 0.939, 0.976, 0.975, and 0.983, respectively. These results demonstrate commendable safety and performance of the test valve system over the short term in a broad European setting. Copyright © 2017 The

  6. Trends in Aortic Valve Replacement Procedures Between 2009 and 2015: Has Transcatheter Aortic Valve Replacement Made a Difference?

    PubMed

    Culler, Steven D; Cohen, David J; Brown, Phillip P; Kugelmass, Aaron D; Reynolds, Matthew R; Ambrose, Karen; Schlosser, Michael L; Simon, April W; Katz, Marc R

    2018-04-01

    This study reports trends in volume and adverse events associated with isolated aortic valve procedures performed in Medicare beneficiaries between 2009 and 2015. This retrospective study used the annual fiscal year Medicare Provider Analysis and Review file to identify all Medicare beneficiaries undergoing an isolated aortic valve procedure. Outcome measures included three mortality rates and nine in-hospital adverse events. The final study population consisted of 233,660 hospitalizations. During the study period, Medicare beneficiaries undergoing an aortic valve procedure increased from 22,076 to 49,362, for an average annual growth rate of 14.45%. Transcatheter aortic valve replacement (TAVR) procedures per 100,000 Medicare beneficiaries grew from 10.7 in 2012 to 41.1 in 2015. Overall, in-hospital mortality rates, cumulative 30-day mortality rates, and 90-day postdischarge mortality rates declined annually during the study period. However, the 90-day mortality rate for TAVR was nearly double the rate for the tissue surgical aortic valve replacement group. Nearly 68% of Medicare beneficiaries experienced at least one in-hospital adverse event during their index hospitalization. Medicare beneficiaries undergoing TAVR had the lowest observed adverse events rates among the aortic valve procedures in 2015. The total number of Medicare beneficiaries undergoing isolated aortic valve procedures increased from 47.5 to 88.9 per 100,000 Medicare beneficiaries during the study period. Aortic valve procedures increased significantly during this study period primarily due to the increase in TAVR, with clinical outcomes improving as well. Although long-term outcomes of TAVR are still under investigation, these results are promising. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Optimal Elastomeric Scaffold Leaflet Shape for Pulmonary Heart Valve Leaflet Replacement

    PubMed Central

    Fan, Rong; Bayoumi, Ahmed S.; Chen, Peter; Hobson, Christopher M.; Wagner, William R.; Mayer, John E.; Sacks, Michael S.

    2012-01-01

    Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery. PMID:23294966

  8. MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.

    PubMed

    Kistan, D; Booysen, M; Alexander, G; Madiba, T E

    2017-06-01

    Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients

  9. Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures.

    PubMed

    Chamandi, Chekrallah; Puri, Rishi; Rodriguez-Gabella, Tania; Rodés-Cabau, Josep

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) is a well-established treatment for patients with severe symptomatic aortic stenosis who are at high or prohibitive surgical risk. More recently, TAVR has emerged as a valid alternative to surgical aortic valve replacement for treating intermediate-risk patients, and several studies are currently evaluating the role of TAVR in low-risk patients. Transcatheter heart valve (THV) technologies have evolved considerably over time, and important iterations have been implemented in many of the latest-generation devices to (1) reduce the size and improve delivery system properties; (2) improve valve deployment, repositioning, and retrievability; and (3) reduce paravalvular leaks. This article reviews the main characteristics of, and clinical results associated with, the newer-generation THVs while providing an overview of novel TAVR indications. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].

    PubMed

    Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio

    2015-07-01

    A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.

  11. Survival after Aortic Valve Replacement with Bovine or Porcine Valve Prostheses: A Systematic Review and Meta-Analysis.

    PubMed

    Glaser, Natalie; Jackson, Veronica; Franco-Cereceda, Anders; Sartipy, Ulrik

    2018-05-17

     Bovine and porcine bioprostheses are commonly used for surgical aortic valve replacement. It is unknown if the long-term survival differs between the two valve types.We performed a systematic review and meta-analysis to compare survival in patients who underwent aortic valve replacement and received a bovine or a porcine prosthesis.  We performed a systematic search of Medline, Embase, Web of Science, and the Cochrane Library. Cohort studies that compared survival between patients who underwent aortic valve replacement and received either a bovine or a porcine bioprosthesis and that reported overall long-term survival with hazard ratio (HR) and 95% confidence interval (CI) were included. Two authors independently reviewed articles considered for inclusion, extracted the information from each study, and performed the quality assessment. We performed a meta-analysis using a random effects model to calculate the pooled HR (95% CI) for all-cause mortality. We did sensitivity analyses to assess the robustness of our findings.  Seven studies published between 2010 and 2015 were included, and the combined study population was 49,190 patients. Of these, 32,235 (66%) received a bovine, and 16,955 (34%) received a porcine bioprosthesis. There was no significant difference in all-cause mortality between patients who received a bovine compared with a porcine bioprosthesis (pooled HR 1.00, 95% CI: 0.92-1.09). Heterogeneity between studies was moderate (55.8%, p  = 0.04).  This systematic review and meta-analysis suggest no difference in survival between patients who received a bovine versus a porcine bioprosthesis after aortic valve replacement. Our study provides valuable evidence for the continuing use of both bovine and porcine bioprosthetic valves for surgical aortic valve replacement. Georg Thieme Verlag KG Stuttgart · New York.

  12. Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.

    PubMed

    Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F

    1983-09-01

    Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.

  13. Tricuspid valve replacement with mechanical prostheses: Short and long-term outcomes.

    PubMed

    Rossello, Xavier; Muñoz-Guijosa, Christian; Mena, Elisabet; Camprecios, Marta; Mendez, Ana B; Borras, Xavier; Padro, Josep M

    2017-09-01

    Tricuspid valve replacement has been associated with high mortality and poor long-term outcomes. We report the preoperative risk factors associated with short and long-term outcomes following tricuspid valve replacement with mechanical prostheses. In 62 patients who underwent mechanical tricuspid valve replacement, clinical, laboratory, and echocardiographic findings were analyzed using both univariate and multivariate analyses to describe operative and long-term mortality. In our population (mean age 59 ± 9.7 years, 82.3% female), most common causes of tricuspid valve disease were rheumatic fever (69.4%) and functional regurgitation (19.4%). Operative and long-term mortality were 17.7 and 33.9%, respectively. Age, diabetes mellitus, and coronary artery disease were independently associated with increased long-term mortality. New York Heart Association (NYHA) class and right heart failure symptoms significantly improved during follow-up. In this series of mechanical tricuspid valve replacements in patients with predominately rheumatic heart disease, operative and long-term mortality were increased; however, survivors had significant improvement in their NYHA class and freedom from right heart failure symptoms. Three preoperative factors (age, diabetes mellitus, and coronary artery disease) were independently associated with long-term mortality. © 2017 Wiley Periodicals, Inc.

  14. Left main coronary artery obstruction by dislodged native-valve calculus after transcatheter aortic valve replacement.

    PubMed

    Durmaz, Tahir; Ayhan, Huseyin; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-08-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement.

  15. Left Main Coronary Artery Obstruction by Dislodged Native-Valve Calculus after Transcatheter Aortic Valve Replacement

    PubMed Central

    Durmaz, Tahir; Keles, Telat; Aslan, Abdullah Nabi; Erdogan, Kemal Esref; Sari, Cenk; Bilen, Emine; Akcay, Murat; Bozkurt, Engin

    2014-01-01

    Transcatheter aortic valve replacement can be an effective, reliable treatment for severe aortic stenosis in surgically high-risk or ineligible patients. However, various sequelae like coronary artery obstruction can occur, not only in the long term, but also immediately after the procedure. We present the case of a 78-year-old woman whose left main coronary artery became obstructed with calculus 2 hours after the transfemoral implantation of an Edwards Sapien XT aortic valve. Despite percutaneous coronary intervention in that artery, the patient died. This case reminds us that early recognition of acute coronary obstruction and prompt intervention are crucial in patients with aortic stenosis who have undergone transcatheter aortic valve replacement. PMID:25120396

  16. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    PubMed

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  17. Dissection of the atrial wall after mitral valve replacement.

    PubMed Central

    Lukács, L; Kassai, I; Lengyel, M

    1996-01-01

    We describe an unusual sequela of mitral valve replacement in a 50-year-old woman who had undergone a closed mitral commissurotomy in 1975. She was admitted to our hospital because of mitral restenosis in November 1993, at which time her mitral valve was replaced with a mechanical prosthesis. On the 8th postoperative day, the patient developed symptoms of heart failure; transesophageal echocardiography revealed dissection and rupture of the left atrial wall. At prompt reoperation, we found an interlayer dissection and rupture of the atrial wall into the left atrium. We repaired the ruptured atrial wall with a prosthetic patch. The postoperative course was uneventful, and postoperative transesophageal echocardiography showed normal prosthetic valve function and no dissection. Images PMID:8680278

  18. [Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].

    PubMed

    Horstkotte, D; Körfer, R; Budde, T; Haerten, K; Schulte, H D; Bircks, W; Loogen, F

    1983-05-01

    Valve-related complications after Björk-Shiley mitral (n = 475), aortic (n = 424), or mitral-aortic implantation (n = 119) were compared to complications after St. Jude mitral (n = 173), aortic (n = 152), and St. Jude mitral and aortic (n = 63) replacements. The 1,018 consecutive patients with Björk-Shiley valves had been operated upon between 1974 and 1982, those with St. Jude valves between 1978 and 1982. All patients were placed on anticoagulant therapy with phenprocoumon early after operation and no significant intergroup differences in the effectiveness of the anticoagulant therapy were found. At a comparable follow-up time of approximately 23 months, 24 major thromboembolic episodes were observed after Björk-Shiley mitral (BSM) and 3 after St. Jude mitral valve implantation (SJM), corresponding to a thromboembolic rate of 2.82/100 patient years with BSM and 0.93/100 patient years with SJM. After aortic valve replacements, 1.93 events in 100 patient years occurred after Björk-Shiley aortic (BSA) and 0.73 after St. Jude aortic implantation (SJA). In patients with double valve replacements, these rates were 3.2 (BSM + BSA) and 0.88 (SJM + SJA), respectively. The cerebral vessels were involved in 52% and the arteries of the extremities in 22% of these major events. Six Björk-Shiley prostheses had to be replaced because of valve thrombosis. The overall incidence of severe hemorrhagic complications was 2.94/100 patient years in BSM and 1.79 in SJM. After aortic valve replacement, we found rates of 1.80/100 patient years (BSA) and 2.57/100 patient years (SJA), respectively. Intravascular hemolysis no longer seems to be a significant clinical problem. However, indications of red cell damage after heart valve replacement were significantly greater in patients with perivalvular leakage, valve thrombosis, or dysfunction than in those with normally functioning prostheses. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2

  19. Pledget Induced Cardiogenic Shock Following a Minimally Invasive Aortic Valve Replacement.

    PubMed

    Tedesco, Alexandra E; Tedesco, Victor E

    2017-01-01

    Within the last decade, minimally invasive valve replacements have become exceedingly popular, and as a result, so has the rise of technology aimed at refining and simplifying these techniques. With new technology, new complications are inevitable. We present a routine Minimally invasive aortic valve replacement through a right anterior minithoracotomy complicated by pledget impaction in a coronary artery.

  20. Haemodynamic results of replacement of mitral and aortic valves with autologous fascia lata prostheses

    PubMed Central

    Talavlikar, P. H.; Walbaum, P. R.; Kitchin, A. H.

    1973-01-01

    Twelve patients undergoing aortic and 28 undergoing mitral valve replacement with autologous fascia lata valves were studied before and six months after surgery. One aortic and 10 mitral valves were found to be significantly incompetent. Of the incompetent mitral valves, two appeared to have perivalvular leaks. Six of the remainder were associated with abnormal ventricular filling patterns. Valve failure was much less common when the design was modified to provide a loose cusp structure; out of 12 such valves none was incompetent. Transvalvular gradients persist with fascial valves though they are lower than with most mechanical prostheses. Ventricular function was greatly improved in successful aortic replacement but remained impaired in the case of mitral replacement. Valve failure appeared to be associated with, or accelerated by, haemodynamic stress rather than due to inevitable degenerative pathological processes. PMID:4731108

  1. Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement

    NASA Technical Reports Server (NTRS)

    Sitges, M.; Kapadia, S.; Rubin, D. N.; Thomas, J. D.; Tuzcu, M. E.; Lever, H. M.

    2001-01-01

    When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.

  2. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    PubMed

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P < 0.001). Pressures outside adjacent sutures (extrasuture) were less than 80 mm Hg in 10 of 60 HT, zero of 60 KP, and zero of 120 TF sites for 15 × 4-mm valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P < 0.001 all manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.

  3. Valve-sparing aortic root replacement in Loeys-Dietz syndrome.

    PubMed

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-08-01

    Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Surgical Approaches to Aortic Valve Replacement and Repair—Insights and Challenges

    PubMed Central

    Ramchandani, Mahesh; Reardon, Michael J

    2014-01-01

    Since 1960, surgical aortic valve replacement (sAVR) had been the only effective treatment for symptomatic severe aortic stenosis until the recent development of transcatheter aortic valve replacement (TAVR). TAVR has offered an alternative, minimally invasive treatment approach particularly for patients whose age or co-morbidities make them unsuitable for sAVR. The rapid and enthusiastic utilization of this new technique has triggered some speculation about the imminent demise of sAVR. We believe that despite the recent advances in TAVR, surgical approach to aortic valve replacement has continued to develop and will continue to be highly relevant in the future. This article will discuss the recent developments and current approaches for sAVR, and how these approaches will keep pace with catheter-based technologies. PMID:29588775

  5. The value of aortic valve replacement in elderly patients: an economic analysis.

    PubMed

    Wu, YingXing; Grunkemeier, Gary L; Starr, Albert

    2007-03-01

    Economists have designed frameworks to measure the economic value of improvements in health and longevity. Heart valve replacement surgery has significantly prolonged life expectancy and quality of life. For the example of aortic valve replacement, what is its economic value according to this framework? From 1961 through 2003, a total of 4617 adult patients underwent aortic valve replacement by one team of cardiac surgeons. These patients were provided with a prospective lifetime follow-up service. As of 2005, observed follow-up was 31,671 patient-years, with a maximum of 41 years. A statistical model was used to generate the future life-years of patients currently alive. The value of life-years proposed by economists was applied to determine the economic value of the additional life given to these patients by aortic valve replacement. The total life-years after aortic valve replacement were 53,323, with a gross value of 14.6 billion dollars. The total expected life-years without surgery were 10,157, with an estimated value of 3.0 billion dollars. Thus the net life-years gained by AVR were 43,166, worth 11.6 billion dollars. Subtracting the 451 million dollars total lifetime cost of surgery, the net value of the life-years gained by AVR was 11.2 billion dollars. The mean net value decreases according to age at surgery but is still worth 600,000 dollars for octogenarians and 200,000 dollars for nonagenarians. According to the economic concept of the value of a statistical life, the return on the investment for aortic valve replacement is enormous for patients of all ages, even very elderly patients.

  6. Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.

    PubMed

    Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D

    2017-08-01

    The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.

  7. Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.

    PubMed

    Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A

    2017-10-01

    The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p < 0.001). Early pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    PubMed

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis.

    PubMed

    Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad

    2018-05-20

    Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.

  10. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.

    PubMed

    Reardon, Michael J; Van Mieghem, Nicolas M; Popma, Jeffrey J; Kleiman, Neal S; Søndergaard, Lars; Mumtaz, Mubashir; Adams, David H; Deeb, G Michael; Maini, Brijeshwar; Gada, Hemal; Chetcuti, Stanley; Gleason, Thomas; Heiser, John; Lange, Rüdiger; Merhi, William; Oh, Jae K; Olsen, Peter S; Piazza, Nicolo; Williams, Mathew; Windecker, Stephan; Yakubov, Steven J; Grube, Eberhard; Makkar, Raj; Lee, Joon S; Conte, John; Vang, Eric; Nguyen, Hang; Chang, Yanping; Mugglin, Andrew S; Serruys, Patrick W J C; Kappetein, Arie P

    2017-04-06

    Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number

  11. Patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement. Experimental study.

    PubMed

    Manouguian, S; Abu-Aishah, N; Neitzel, J

    1979-09-01

    The experimental results of patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement are reported. The operative technique of this new surgical method is described and the indications are discussed.

  12. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    To demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model. The CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach. Two imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function. Our results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Cost-effectiveness of aortic valve replacement in the elderly: an introductory study.

    PubMed

    Wu, YingXing; Jin, Ruyun; Gao, Guangqiang; Grunkemeier, Gary L; Starr, Albert

    2007-03-01

    With increased life expectancy and improved technology, valve replacement is being offered to increasing numbers of elderly patients with satisfactory clinical results. By using standard econometric techniques, we estimated the relative cost-effectiveness of aortic valve replacement by drawing on a large prospective database at our institution. By using aortic valve replacement as an example, this introductory report paves the way to more definitive studies of these issues in the future. From 1961 to 2003, 4617 adult patients underwent aortic valve replacement at our service. These patients were provided with a prospective lifetime follow-up. As of 2005, these patients had accumulated 31,671 patient-years of follow-up (maximum 41 years) and had returned 22,396 yearly questionnaires. A statistical model was used to estimate the future life years of patients who are currently alive. In the absence of direct estimates of utility, quality-adjusted life years were estimated from New York Heart Association class. The cost-effectiveness ratio was calculated by the patient's age at surgery. The overall cost-effectiveness ratio was approximately 13,528 dollars per quality-adjusted life year gained. The cost-effectiveness ratio increased according to age at surgery, up to 19,826 dollars per quality-adjusted life year for octogenarians and 27,182 dollars per quality-adjusted life year for nonagenarians. Given the limited scope of this introductory study, aortic valve replacement is cost-effective for all age groups and is very cost-effective for all but the most elderly according to standard econometric rules of thumb.

  14. Evolving trends in aortic valve replacement: A statewide experience.

    PubMed

    Kim, Karen M; Shannon, Francis; Paone, Gaetano; Lall, Shelly; Batra, Sanjay; Boeve, Theodore; DeLucia, Alphonse; Patel, Himanshu J; Theurer, Patricia F; He, Chang; Clark, Melissa J; Sultan, Ibrahim; Deeb, George Michael; Prager, Richard L

    2018-06-17

    Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) for the treatment of aortic stenosis in patients at intermediate, high, and extreme risk for mortality from SAVR. We examined recent trends in aortic valve replacement (AVR) in Michigan. The Michigan Society of Thoracic and Cardiovascular Surgeons Quality Collaborative (MSTCVS-QC) database was used to determine the number of SAVR and TAVR cases performed from January 2012 through June 2017. Patients were divided into low, intermediate, high, and extreme risk groups based on STS predicted risk of mortality (PROM). TAVR patients in the MSTCVS-QC database were also matched with those in the Transcatheter Valve Therapy Registry to determine their Heart Team-designated risk category. During the study period 9517 SAVR and 4470 TAVR cases were performed. Total annual AVR volume increased by 40.0% (from 2086 to 2920), with a 13.3% decrease in number of SAVR cases (from 1892 to 1640) and a 560% increase in number of TAVR cases (from 194 to 1280). Greater than 90% of SAVR patients had PROM ≤8%. While >70% of TAVR patients had PROM ≤ 8%, they were mostly designated as high or extreme risk by a Heart Team. During the study period, SAVR volume gradually declined and TAVR volume dramatically increased. This was mostly due to a new group of patients with lower STS PROM who were designated as higher risk by a Heart Team due to characteristics not completely captured by the STS PROM score. © 2018 Wiley Periodicals, Inc.

  15. Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management.

    PubMed

    Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi

    2006-01-01

    Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.

  16. Management of mitral regurgitation in Marfan syndrome: Outcomes of valve repair versus replacement and comparison with myxomatous mitral valve disease.

    PubMed

    Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M

    2014-09-01

    The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. Medium-term outcome of Toronto aortic valve replacement: single center experience.

    PubMed

    Li, Wei; Price, Susanna; O'Sullivan, Christine A; Kumar, Pankaj; Jin, Xu Y; Henein, Michael Y; Pepper, John R

    2008-09-26

    Long-term competence of any aortic prosthesis is critical to its clinical durability. Bioprosthetic valves, and in particular the stentless type have been proposed to offer superior haemodynamic profiles with consequent potential for superior left-ventricular mass regression. These benefits however are balanced by the potential longevity of the implanted valve. The aims of this study were to assess medium-term Toronto aortic valve function and its effect on left-ventricular function. Between 1992 and 1996 86 patients underwent Toronto aortic valve replacement for aortic valve disease and were followed up annually. Prospectively collected data was analyzed for all patients where detailed echocardiographic follow-up was available. Echocardiographic studies were analyzed at 2+/-0.6 and 6+/-1.4 years after valve replacement. Data collected included left-ventricular systolic and diastolic dimensions, fractional shortening and left-ventricular mass. In addition, data on aortic valve and root morphology, peak aortic velocities, time velocity integral, stroke volume and the mechanism of valve failure where relevant, were also collected. Complete echocardiographic data were available for eighty-four patients, age 69+/-9 years, 62 male. Additional coronary artery bypass grafting was performed in 38% of patients. Twelve (14%) valves had failed during follow-up, 7 (8%) requiring re-operation. Valve failure was associated with morphologically bicuspid native aortic valve (9/12), and progressive dilatation of the aortic sinuses, sino-tubular junction and ascending aorta (11/12). Left-ventricular mass index remained high (184+/-75 g/m(2)) and did not continue to regress between early and medium-term follow-up (175.8+/-77 g/m(2)). Although more than 90% of implanted Toronto aortic valves remained haemodynamically stable with low gradient at medium-term follow-up, young age and larger aortic dimensions in patients with valve failure suggest better outcome if used in the elderly

  18. The impact of mitral stenosis on outcomes of aortic valve stenosis patient undergoing surgical aortic valve replacement or transcatheter aortic valve replacement.

    PubMed

    Al-Khadra, Yasser; Darmoch, Fahed; Baibars, Motaz; Kaki, Amir; Fanari, Zaher; Alraies, M Chadi

    2018-05-17

    The concomitant presence of mitral stenosis (MS) in the setting of symptomatic aortic stenosis represent a clinical challenge. Little is known regarding the outcome of mitral stenosis (MS) patients undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). Therefore, we sought to study the outcome of MS patients undergoing aortic valve replacement (AVR). Using weighted data from the National Inpatient Sample (NIS) database between 2011 and 2014, we identified patients who were diagnosed with MS. Patients who had undergone TAVR as a primary procedure were identified and compared to patients who had SAVR. Univariate and multivariate logistic regression analysis were performed for the outcomes of in-hospital mortality, length of stay (LOS), blood transfusion, postprocedural hemorrhage, vascular, cardiac and respiratory complications, permanent pacemaker placement (PPM), postprocedural stroke, acute kidney injury (AKI), and discharge to an outside facility. A total of 4524 patients were diagnosed with MS, of which 552 (12.2%) had TAVR and 3972 (87.8%) had SAVR. TAVR patients were older (79.9 vs 70.0) with more females (67.4% vs 60.0%) and African American patients (7.7% vs 7.1%) (P < 0.001). In addition, the TAVR group had more comorbidities compared to SAVR in term of coronary artery disease (CAD), congestive heart failure (CHF), chronic lung disease, hypertension (HTN), chronic kidney disease (CKD), and peripheral vascular disease (PVD) (P < 0.001 for all). Using Multivariate logistic regression, and after adjusting for potential risk factors, TAVR patients had lower in-hospital mortality (7.9% vs 8.1% adjusted Odds Ratio [aOR], 0.615; 95% confidence interval [CI], 0.392-0.964, P = 0.034), shorter LOS. Also, TAVR patients had lower rates of cardiac and respiratory complications, PPM, AKI, and discharge to an outside facility compared with the SAVR group. In patients with severe aortic stenosis and concomitant

  19. Neurocognitive functions after beating heart mitral valve replacement without cross-clamping the aorta.

    PubMed

    Cicekcioglu, Ferit; Ozen, Anil; Tuluce, Hicran; Tutun, Ufuk; Parlar, Ali Ihsan; Kervan, Umit; Karakas, Sirel; Katircioglu, Salih Fehmi

    2008-01-01

    Although neurologic outcome after cardiac surgery is well-established, neurocognitive functions after beating heart mitral valve replacement still needs to be elucidated. The aim of this study was to compare preoperative and postoperative neurocognitive functions in patients who underwent beating heart mitral valve replacement on cardiopulmonary bypass without cross-clamping the aorta. The prospective study included 25 consecutive patients who underwent mitral valve replacement. The operations were carried out on a beating heart method using normothermic cardiopulmonary bypass without cross-clamping the aorta. All patients were evaluated preoperatively (E1) and postoperatively (at sixth day [E2] and second month [E3]) for neurocognitive functions. Neurologic deficit was not observed in the postoperative period. Comparison of the neurocognitive test results, between the preoperative and postoperative assessment for both hemispheric cognitive functions, demonstrated that no deterioration occurred. In the three subsets of left hemispheric cognitive function test evaluation, total verbal learning, delayed recall, and recognition, significant improvements were detected at the postoperative second month (E3) compared to the preoperative results (p = 0.005, 0.01, and 0.047, respectively). Immediate recall and retention were significantly improved within the first postoperative week (E2) when compared to the preoperative results (p = 0.05 and 0.05, respectively). The technique of mitral valve replacement with normothermic cardiopulmonary bypass without cross-clamping of the aorta may be safely used for majority of patients requiring mitral valve replacement without causing deterioration in neurocognitive functions.

  20. Successful replacement of the systemic tricuspid valve with a mechanical valve in a 3-month-old boy with congenitally corrected transposition of the great arteries having a dysplastic tricuspid valve.

    PubMed

    Asada, Dai; Ikeda, Kazuyuki; Yamagishi, Masaaki

    2017-04-01

    There are a few reports of successful replacement of the left-sided systemic tricuspid valve with a mechanical valve in small infants with congenitally corrected transposition of the great arteries having Ebstein's anomaly. Tricuspid valve replacement is the preferred option when pulmonary artery banding, performed as a prelude to performing the double-switch operation, is not feasible because of severe heart failure caused by tricuspid regurgitation.

  1. Mitral valve replacement for mitral stenosis: A 15-year single center experience.

    PubMed

    Al Mosa, Alqasem F; Omair, Aamir; Arifi, Ahmed A; Najm, Hani K

    2016-10-01

    Mitral valve replacement with either a bioprosthetic or a mechanical valve is the treatment of choice for severe mitral stenosis. However, choosing a valve implant type is still a subject of debate. This study aimed to evaluate and compare the early and late outcomes of mitral valve replacement [mechanical (MMV) vs. bioprosthetic (BMV)] for severe mitral stenosis. A retrospective cohort study was performed on data involving mitral stenosis patients who have undergone mitral valve replacement with either BMV (n = 50) or MMV (n = 145) valves from 1999 to 2012. Data were collected from the patients' records and follow-up through telephone calls. Data were analyzed for early and late mortality, New York Heart Association (NYHA) functional classes, stroke, pre- and postoperative echocardiographic findings, early and late valve-related complications, and survival. Chi-square test, logistic regression, Kaplan-Meier curve, and dependent proportions tests were some of the tests employed in the analysis. A total of 195 patients were included in the study with a 30-day follow-up echocardiogram available for 190 patients (97.5%), while 103 (53%) were available for follow-up over the telephone. One patient died early postoperatively; twelve patients died late in the postoperative period, six in the bioprosthesis group and six in the mechanical group. The late mortality had a significant association with postoperative stroke (p < 0.001) and postoperative NYHA Classes III and IV (p = 0.002). Postoperative NYHA class was significantly associated with age (p = 0.003), pulmonary disease (p = 0.02), mitral valve implant type (p = 0.01), and postoperative stroke (p = 0.02); 14 patients had strokes in the mechanical (9) and in the bioprosthetic (5) groups. NYHA classes were significantly better after the replacement surgeries (p < 0.001). BMV were significantly associated with worse survival (p = 0.03), worse NYHA postoperatively (p = 0.01), and more reoperations

  2. Long-term Outcomes of Mitral Valve Repair Versus Replacement for Degenerative Disease: A Systematic Review

    PubMed Central

    McNeely, Christian A; Vassileva, Christina M

    2015-01-01

    The short-term advantage of mitral valve repair versus replacement for degenerative disease has been extensively documented. These advantages include lower operative mortality, improved survival, better preservation of left-ventricular function, shorter post-operative hospital stay, lower total costs, and fewer valve-related complications, including thromboembolism, anticoagulation-related bleeding events and late prosthetic dysfunction. More recent written data are available indicating the long-term advantage of repair versus replacement. While at some institutions, the repair rate for degenerative disease may exceed 90%, the national average in 2007 was only 69%. Making direct comparisons between mitral valve repair and replacement using the available studies does present some challenges however, as there are often differences in baseline characteristics between patient groups as well as other dissimilarities between studies. The purpose of this review is to systematically summarize the long-term survival and reoperation data of mitral valve repair versus replacement for degenerative disease. A PubMed search was done and resulted in 12 studies that met our study criteria for comparing mitral valve repair versus replacement for degenerative disease. A systematic review was then conducted abstracting survival and reoperation data. PMID:25158683

  3. Aortic valve replacement in elderly patients.

    PubMed

    Glock, Y; Pecoul, R; Cerene, A; Laguerre, J; Puel, P

    1984-01-01

    The results for 62 consecutive patients aged 70 or more given aortic valve replacement (A.V.R.) between 1970 and 1982 are reported. All the patients were in the New York Heart Association (N.Y.H.A.) functional class III (29%) or IV (71%); 54.8% had angina and 30.6% had experienced syncope. Forty patients had aortic stenosis (A.S.), 10 had aortic regurgitation and 12 had mixed aortic valve disease. The operative myocardial infarction rate was 6.4%. Tilting disk valves were used. Eighty percent of the patients were anticoagulated with Warfarin whilst twenty percent received only antiplatelet drugs. All the patients were followed up for a mean period of 26 months; late mortality was 22.6% with 4.8% cardiac deaths. The thromboembolic rate was 1.6% and the disinsertion rate was 3.2%. Cerebral stroke was fatal in 3 cases in anticoagulated patients but the mechanism of the accident was not known. At the termination of the study 93% of surviving patients were in N.Y.H.A. class I or II. No patient was in class IV. The probability of five year survival is 71% for the entire group.

  4. High Risk Aortic Valve Replacement - The Challenges of Multiple Treatment Strategies with an Evolving Technology.

    PubMed

    Booth, K; Beattie, R; McBride, M; Manoharan, G; Spence, M; Jones, J M

    2016-01-01

    Deciding on the optimal treatment strategy for high risk aortic valve replacement is challenging. Transcatheter Aortic Valve implantation (TAVI) has been available in our centre as an alternative treatment modality for patients since 2008. We present our early experience of TAVI and SAVR (surgical Aortic Valve Replacement) in high risk patients who required SAVR because TAVI could not be performed. The database for Surgical aortic valve and Transcatheter aortic valve replacement referrals was interrogated to identify relevant patients. Survival to hospital discharge was 95.5% in the forty five patients who had SAVR when TAVI was deemed technically unsuitable. One year survival was 86%. Defining who is appropriate for TAVI or high risk SAVR is challenging and multidisciplinary team discussion has never been more prudent in this field of evolving technology with ever decreasing risks of surgery. The introduction of TAVI at our institution has seen a rise in our surgical caseload by approximately by 25%. Overall, the option of aortic valve intervention is being offered to more patients in general which is a substantial benefit in the treatment of aortic valve disease.

  5. Transcatheter Aortic Valve Replacement: a Kidney’s Perspective

    PubMed Central

    Cheungpasitporn, Wisit; Thongprayoon, Charat; Kashani, Kianoush

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) has now emerged as a viable treatment option for high-risk patients with severe aortic stenosis (AS) who are not suitable candidates for surgical aortic valve replacement (SAVR). Despite encouraging published outcomes, acute kidney injury (AKI) is common and lowers the survival of patients after TAVR. The pathogenesis of AKI after TAVR is multifactorial including TAVR specific factors such as the use of contrast agents, hypotension during rapid pacing, and embolization; preventive measures may include pre-procedural hydration, limitation of contrast dye exposure, and avoidance of intraprocedural hypotension. In recent years, the number of TAVR performed worldwide has been increasing, as well as published data on renal perspectives of TAVR including AKI, chronic kidney disease, end-stage kidney disease, and kidney transplantation. This review aims to present the current literature on the nephrology aspects of TAVR, ultimately to improve the patients’ quality of care and outcomes. PMID:27069960

  6. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

    PubMed

    Leon, Martin B; Smith, Craig R; Mack, Michael J; Makkar, Raj R; Svensson, Lars G; Kodali, Susheel K; Thourani, Vinod H; Tuzcu, E Murat; Miller, D Craig; Herrmann, Howard C; Doshi, Darshan; Cohen, David J; Pichard, Augusto D; Kapadia, Samir; Dewey, Todd; Babaliaros, Vasilis; Szeto, Wilson Y; Williams, Mathew R; Kereiakes, Dean; Zajarias, Alan; Greason, Kevin L; Whisenant, Brian K; Hodson, Robert W; Moses, Jeffrey W; Trento, Alfredo; Brown, David L; Fearon, William F; Pibarot, Philippe; Hahn, Rebecca T; Jaber, Wael A; Anderson, William N; Alu, Maria C; Webb, John G

    2016-04-28

    Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).

  7. Beating heart mitral valve replacement with a bovine pericardial bioprosthesis for treatment of mitral valve dysplasia in a Bull Terrier.

    PubMed

    Behr, Luc; Chetboul, Valérie; Sampedrano, Carolina Carlos; Vassiliki, Gouni; Pouchelon, Jean-Louis; Laborde, François; Borenstein, Nicolas

    2007-04-01

    To describe an open, beating heart surgical technique and use of a bovine pericardial prosthetic valve for mitral valve replacement (MVR) in the dog. Clinical case report. Male Bull Terrier (17-month-old, 26 kg) with mitral valve dysplasia and severe regurgitation. A bovine pericardial bioprosthesis was used to replace the mitral valve using an open beating heart surgical technique and cardiopulmonary bypass. Successful MVR was achieved using a beating heart technique. Mitral regurgitation resolved and cardiac performances improved (left ventricular end-diastolic diameter decreased from 57.6 to 48.7 mm, and left atrium/aorta ratio returned to almost normal, from 1.62 to 1.19). Cardiopulmonary by-pass time and total surgical duration were decreased compared with standard cardioplegic techniques. Surgical recovery was uneventful and on echocardiography 6 months later valve function was excellent. Considering the technique advantages (no cardiac arrest, ischemic reperfusion injury, and hypothermia, or the need for aortic dissection and cannulation for administration of cardioplegic solution), short-term mortality and morbidity may be reduced compared with standard cardioplegic techniques. Based on experience in this dog, beating heart mitral valvular replacement is a seemingly safe and viable option for the dog and bovine pericardial prosthesis may provide better long-term survival than mechanical prostheses.

  8. Vascular complications of transcatheter aortic valve replacement: A concise literature review

    PubMed Central

    Chaudhry, Muhammad Ali; Sardar, Muhammad Rizwan

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) is a relatively newer therapeutic modality which offers a promising alternative to surgical aortic valve replacement for patients with prohibitive, high and intermediate surgical risk. The increasing trend to pursue TAVR in these patients has also led to growing awareness of the associated potential vascular complications. The significant impact of these complications on eventual clinical outcome and mortality makes prompt recognition and timely management a critical factor in TAVR patients. We hereby present a concise review with emphasis on diverse vascular complications associated with TAVR and their effective management to improve overall clinical outcomes. PMID:28824787

  9. COMBINED REPLACEMENT OF THE AORTIC VALVE AND ASCENDING AORTA IN JEHOVAH'S WITNESSES: REPORT OF TWO CASES

    PubMed Central

    Beddermann, Christoph; Norman, John C.; Cooley, Denton A.

    1979-01-01

    Two Jehovah's Witnesses with large ascending thoracic aortic aneurysms and aortic insufficiency secondary to annuloaortic ectasia underwent successful combined replacement of the aortic valve and the ascending aorta. One patient received a composite graft containing an aortic valve prosthesis, which necessitated supravalvular coronary ostia reimplantation; the other patient underwent separate aortic valve and left supracoronary ascending aneurysm replacement, with reimplantation of the right coronary ostium into the graft. No blood or blood derivatives were administered. Both patients had uneventful recoveries and continue to do well. To our knowledge, they represent the first reported cases of successful combined replacement of the aortic valve and ascending aorta in Jehovah's Witnesses. Images PMID:15216324

  10. Coronary ostia obstruction after replacement of aortic valve prostesis

    PubMed Central

    2011-01-01

    Aortic valve replacement (AVR) is the gold standard for the treatment of severe symptomatic aortic stenosis. Complications directly related to surgical procedure are relatively infrequent. Coronary ostial stenosis is, generally, referred as late complication. Anecdotal reports concern coronary ostial stenosis as acute complication. A unique fatal case of intraoperative, bilateral coronary ostial obstruction by prosthetic valve leading to an extensive myocardial infarction is reported. Surgeons must have a high level of vigilance regarding the occurrence of acute myocardial ischemia and sudden death soon after AVR. PMID:21810231

  11. One-year outcome following biological or mechanical valve replacement for infective endocarditis.

    PubMed

    Delahaye, F; Chu, V H; Altclas, J; Barsic, B; Delahaye, A; Freiberger, T; Gordon, D L; Hannan, M M; Hoen, B; Kanj, S S; Lejko-Zupanc, T; Mestres, C A; Pachirat, O; Pappas, P; Lamas, C; Selton-Suty, C; Tan, R; Tattevin, P; Wang, A

    2015-01-15

    Nearly half of patients require cardiac surgery during the acute phase of infective endocarditis (IE). We describe the characteristics of patients according to the type of valve replacement (mechanical or biological), and examine whether the type of prosthesis was associated with in-hospital and 1-year mortality. Among 5591 patients included in the International Collaboration on Endocarditis Prospective Cohort Study, 1467 patients with definite IE were operated on during the active phase and had a biological (37%) or mechanical (63%) valve replacement. Patients who received bioprostheses were older (62 vs 54years), more often had a history of cancer (9% vs 6%), and had moderate or severe renal disease (9% vs 4%); proportion of health care-associated IE was higher (26% vs 17%); intracardiac abscesses were more frequent (30% vs 23%). In-hospital and 1-year death rates were higher in the bioprosthesis group, 20.5% vs 14.0% (p=0.0009) and 25.3% vs 16.6% (p<.0001), respectively. In multivariable analysis, mechanical prostheses were less commonly implanted in older patients (odds ratio: 0.64 for every 10years), and in patients with a history of cancer (0.72), but were more commonly implanted in mitral position (1.60). Bioprosthesis was independently associated with 1-year mortality (hazard ratio: 1.298). Patients with IE who receive a biological valve replacement have significant differences in clinical characteristics compared to patients who receive a mechanical prosthesis. Biological valve replacement is independently associated with a higher in-hospital and 1-year mortality, a result which is possibly related to patient characteristics rather than valve dysfunction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Consequence of patient substitution of nattokinase for warfarin after aortic valve replacement with a mechanical prosthesis.

    PubMed

    Elahi, Maqsood M; Choi, Charles H; Konda, Subbareddy; Shake, Jay G

    2015-01-01

    This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical prosthesis. Nattokinase is an enzyme derived from a popular fermented soybean preparation in Japan (natto), which has fibrinolytic properties and is gaining popularity in nontraditional health journals and nonmedical health websites as an over-the-counter thrombolytic. After nearly a year of use of nattokinase without warfarin, the patient developed thrombus on the mechanical valve and underwent successful repeat valve replacement. We believe this is the first documented case of nattokinase being used as a substitute for warfarin after valve replacement, and we strongly discourage its use for this purpose.

  13. Consequence of patient substitution of nattokinase for warfarin after aortic valve replacement with a mechanical prosthesis

    PubMed Central

    Elahi, Maqsood M.; Choi, Charles H.; Konda, Subbareddy

    2015-01-01

    This report describes a patient's self-substitution of nattokinase for the vitamin K antagonist warfarin after aortic valve replacement with a mechanical prosthesis. Nattokinase is an enzyme derived from a popular fermented soybean preparation in Japan (natto), which has fibrinolytic properties and is gaining popularity in nontraditional health journals and nonmedical health websites as an over-the-counter thrombolytic. After nearly a year of use of nattokinase without warfarin, the patient developed thrombus on the mechanical valve and underwent successful repeat valve replacement. We believe this is the first documented case of nattokinase being used as a substitute for warfarin after valve replacement, and we strongly discourage its use for this purpose. PMID:25552810

  14. Aortic valve replacement and tricuspid valve annuloplasty via a left thoracotomy in an adult with left pulmonary agenesis.

    PubMed

    Furutachi, Akira; Furukawa, Kojiro; Shimauchi, Kouta; Yunoki, Junji; Itoh, Manabu; Takamatsu, Masanori; Nogami, Eijiro; Mukae, Yosuke; Nishida, Takahiro

    2018-06-06

    We report a case of a 66-year-old man who was diagnosed with severe aortic regurgitation, moderate tricuspid regurgitation and chronic atrial fibrillation. Preoperative computed tomography showed left lung agenesis. We performed aortic valve replacement, tricuspid valve annuloplasty and right pulmonary vein isolation via a left thoracotomy. This approach provided an adequate field of view.

  15. Root replacement using stentless valves in the small aortic root: a propensity score analysis.

    PubMed

    Kunihara, Takashi; Schmidt, Kathrin; Glombitza, Petra; Dzindzibadze, Vachtang; Lausberg, Henning; Schäfers, Hans-Joachim

    2006-10-01

    Root replacement using a stentless bioprosthesis may be the optimal approach to avoid patient-prosthesis mismatch in patients with a small aortic root. Primary root replacement, however, is considered to be associated with increased surgical risk. We compared early outcome of full root replacement with a stentless bioprosthesis with that of aortic valve replacement with a stented bioprosthesis using propensity score-matching analysis. Of 231 patients undergoing elective, first-time aortic valve replacement with a small root (< or = 22 mm), 120 patients were selected using propensity score-matching analysis. They underwent either root replacement using a 23-mm stentless bioprosthesis (stentless group, n = 60) or supra-annular aortic valve replacement using a 21-mm stented bioprosthesis (stented group, n = 60). Preoperative characteristics and frequency of concomitant operations were identical. Duration of operation (196 +/- 54 versus 174 +/- 49 minutes), cardiopulmonary bypass (112 +/- 36 versus 91 +/- 33 minutes), and aortic cross-clamping (76 +/- 21 versus 61 +/- 21 minutes) were significantly longer in the stentless group. However, the need for perioperative transfusion and the incidence of postoperative reexploration for bleeding (3% versus 8%) was lower, and ventilation time was shorter. Mean duration of intensive care and hospital stay were also significantly shorter (2.3 +/- 1.7 versus 4.0 +/- 3.9 days, 8.9 +/- 3.1 versus 12.4 +/- 5.7 days). In-hospital mortality was identical (5% each). No independent predictor for in-hospital mortality was identified. Full root replacement using a stentless bioprosthesis does not increase postoperative morbidity or mortality of aortic valve replacement and may be advantageous in patients with a small aortic root.

  16. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    PubMed

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  17. Minimally Invasive Aortic Valve Replacement Following Root Enlargement on too Narrow Annulus to Perform Transcatheter Aortic Valve Implantation.

    PubMed

    Sakamoto, Kosuke; Totsugawa, Toshinori; Hiraoka, Arudo; Tamura, Kentaro; Yoshitaka, Hidenori; Sakaguchi, Taichi

    2018-05-30

    An 88-year-old woman was diagnosed with aortic stenosis and an aortic annulus that was too narrow to perform transcatheter aortic valve implantation. Surgery was performed through a 7-cm right mini-thoracotomy at the fourth intercostal space. A 19-mm aortic valve bioprosthesis was implanted after root enlargement. The fourth intercostal space was a suitable site for aortic root enlargement because of the shorter skin-to-root distance and the detailed exposure of the aortic valve after cutting the aortic wall. This study concluded that minimally-invasive aortic valve replacement following root enlargement can be an option for the treatment of elderly patients with aortic stenosis accompanied by an annulus that is too small to perform transcatheter aortic valve implantation.

  18. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  19. Transcatheter aortic valve replacement: historical perspectives, current evidence, and future directions.

    PubMed

    Horne, Aaron; Reineck, Elizabeth A; Hasan, Rani K; Resar, Jon R; Chacko, Matthews

    2014-10-01

    Severe aortic stenosis (AS) results in considerable morbidity and mortality without aortic valve replacement and is expected to increase in prevalence with the aging population. Because AS primarily affects the elderly, many patients with comorbidities are poor candidates for surgical aortic valve replacement (SAVR) and may not be referred. Transcatheter aortic valve replacement (TAVR) has emerged as transformative technology for the management of AS over the past decade. Randomized trials have established the safety and efficacy of TAVR with improved mortality and quality of life compared with medical therapy in inoperable patients, while demonstrating noninferiority and even superiority to SAVR among high-risk operative candidates. However, early studies demonstrated an early penalty of stroke and vascular complications with TAVR as well as increased paravalvular leak as compared with SAVR. Two device platforms have been evaluated and approved for use in the United States: the Edwards SAPIEN and the Medtronic CoreValve. Early studies also suggest cost-effectiveness for TAVR. Ongoing studies are evaluating new iterations of the aforementioned TAVR devices, novel device designs, and applications of TAVR in expanded populations of patients including those with lower risk profiles as well as those with comorbidities that were excluded from early clinical trials. Future improvements in TAVR technology will likely reduce periprocedural and long-term complications. Further studies are needed to confirm device durability over long-term follow-up and explore the applicability of TAVR to broader AS patient populations. Copyright © 2014 Mosby, Inc. All rights reserved.

  20. Criteria for determining the need for surgical treatment of tricuspid regurgitation during mitral valve replacement

    PubMed Central

    2012-01-01

    Background Tricuspid regurgitation (TR) is common in patients with mitral valve disease; however, there are no straightforward, rapidly determinably criteria available for deciding whether TR repair should be performed during mitral valve replacement. The aim of our retrospective study was to identify a simple and fast criterion for determining whether TR repair should be performed in patients undergoing mitral valve replacement. Methods We reviewed the records of patients who underwent mitral valve replacement with or without (control) TR repair (DeVega or Kay procedure) from January 2005 to December 2008. Preoperative and 2-year postoperative echocardiographic measurements included right ventricular and atrial diameter, interventricular septum size, TR severity, ejection fraction, and pulmonary artery pressure. Results A total of 89 patients were included (control, n = 50; DeVega, n = 27; Kay, n = 12). Demographic and clinical characteristics were similar between groups. Cardiac variables were similar between the DeVega and Kay groups. Right atrium and ventricular diameter and ejection fraction were significantly decreased postoperatively both in the control and operation (DeVega + Kay) group (P < 0.05). Pulmonary artery pressure was significantly decreased postoperatively in-operation groups (P < 0.05). Our findings indicate that surgical intervention for TR should be considered during mitral valve replacement if any of the following preoperative criteria are met: right atrial transverse diameter > 57 mm; right ventricular end-diastolic diameter > 55 mm; pulmonary artery pressure > 58 mmHg. Conclusions Our findings suggest echocardiography may be used as a rapid and simple means of determining which patients require TR repair during mitral valve replacement. PMID:22443513

  1. Long-term outcome in dogs undergoing mitral valve repair with suture annuloplasty and chordae tendinae replacement.

    PubMed

    Mizuno, T; Mizukoshi, T; Uechi, M

    2013-02-01

    Mitral valve repair under cardiopulmonary bypass was performed in three dogs with clinical signs associated with mitral regurgitation that were not controlled by medication. Mitral valve repair comprised circumferential annuloplasty and chordal replacement with expanded polytetrafluoroethylene. One dog died 2 years after surgery because of severe mitral regurgitation resulting from partial circumferential suture detachment. The others survived for over 5 years, but mild mitral valve stenosis persisted in one. The replaced chordae did not rupture in any dog. Mitral valve repair appears to be an effective treatment for mitral regurgitation in dogs. Chordal replacement with expanded polytetrafluoroethylene is a feasible technique, demonstrating long-term durability in dogs. However, mitral annuloplasty techniques need improvement. © 2012 British Small Animal Veterinary Association.

  2. Aortic valve replacement for stenosis with or without coronary artery bypass grafting after 2 previous isolated coronary artery bypass grafting operations

    PubMed Central

    Lee Henry, Christopher; Ko, Jong Mi; Henry, Albert Carl; Matter, Gregory John

    2011-01-01

    Aortic valve replacement following an earlier coronary artery bypass grafting (CABG) procedure is fairly common. When this situation occurs, the type of valve dysfunction is usually stenosis (with or without regurgitation), and whether it was missed at the time of the earlier CABG or developed subsequently is usually unclear. We attempted to determine the survival in patients who had had aortic valve replacement after 2 previous CABG procedures. We describe 12 patients who had aortic valve replacement for aortic stenosis; rather than one previous CABG operation, all had had 2 previous CABG procedures. Only one patient died in the early postoperative period after aortic valve replacement, and the remaining 11 were improved substantially: all have lived at least 11 months, and one is still alive at over 101 months after aortic valve replacement. Aortic valve replacement remains beneficial for most patients even after 2 previous CABG procedures. PMID:21307968

  3. Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.

    PubMed

    Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi

    2013-09-10

    Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.

  4. Aortic valve replacement during acute rheumatic fever.

    PubMed

    Khan, A; Chi, S; Gonzalez-Lavin, L

    1978-07-01

    Emergency aortic valve replacement was performed during an attack of acute rheumatic fever in a 12-year-old black boy. He had an uneventful recovery and has remained asymptomatic 27 months after operation. In the light of this experience and that of others, one might conclude that the decision to operate on these patients should be based on the severity of the haemodynamic derangement rather than on the state of activity in the rheumatic process.

  5. Aortic valve replacement in octogenarians.

    PubMed

    Bose, Amal K; Aitchison, James D; Dark, John H

    2007-07-13

    As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR) in octogenarians. 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37) underwent isolated AVR whilst 46% (31) underwent combined AVR and CABG. Follow up was 100% complete. The mean age was 83.1 +/- s.d. 2.9 years, a mean gradient of 83 +/- s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 +/- s.d. 1.2, the logistic EuroSCORE mean 12.0 +/- s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p < 0.05). Survival was not adversely affected by the addition of coronary artery bypass grafts to aortic valve replacement, the presence of peripheral vascular disease, hypertension or diabetes. In this study duration of cross clamp or bypass time were not found to reach significance as independent predictors of mortality. Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.

  6. Cost-Effectiveness of Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis Versus Surgical Aortic Valve Replacement

    PubMed Central

    Reynolds, Matthew R.; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A.; Magnuson, Elizabeth A.; Galper, Benjamin Z.; Meduri, Christopher U.; Arnold, Suzanne V.; Baron, Suzanne J.; Reardon, Michael J.; Adams, David H.; Popma, Jeffrey J.; Cohen, David J.

    2016-01-01

    Background Prior studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. Objectives The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. Methods We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk pivotal trial. Empirical data regarding survival and quality of life (QOL) over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. perspective. Results Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month QOL. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years (QALYs; 0.41 life-years [LYs]) with 3% discounting. Lifetime incremental cost-effectiveness ratios (ICERs) were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ~$1,650 would lead to an ICER <$50,000/QALY gained. Conclusions In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. standards. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. PMID:26764063

  7. Society of Thoracic Surgeons Risk Score predicts hospital charges and resource use after aortic valve replacement.

    PubMed

    Arnaoutakis, George J; George, Timothy J; Alejo, Diane E; Merlo, Christian A; Baumgartner, William A; Cameron, Duke E; Shah, Ashish S

    2011-09-01

    The impact of Society of Thoracic Surgeons predicted mortality risk score on resource use has not been previously studied. We hypothesize that increasing Society of Thoracic Surgeons risk scores in patients undergoing aortic valve replacement are associated with greater hospital charges. Clinical and financial data for patients undergoing aortic valve replacement at The Johns Hopkins Hospital over a 10-year period (January 2000 to December 2009) were reviewed. The current Society of Thoracic Surgeons formula (v2.61) for in-hospital mortality was used for all patients. After stratification into risk quartiles, index admission hospital charges were compared across risk strata with rank-sum and Kruskal-Wallis tests. Linear regression and Spearman's coefficient assessed correlation and goodness of fit. Multivariable analysis assessed relative contributions of individual variables on overall charges. A total of 553 patients underwent aortic valve replacement during the study period. Average predicted mortality was 2.9% (±3.4) and actual mortality was 3.4% for aortic valve replacement. Median charges were greater in the upper quartile of patients undergoing aortic valve replacement (quartiles 1-3, $39,949 [interquartile range, 32,708-51,323] vs quartile 4, $62,301 [interquartile range, 45,952-97,103], P < .01]. On univariate linear regression, there was a positive correlation between Society of Thoracic Surgeons risk score and log-transformed charges (coefficient, 0.06; 95% confidence interval, 0.05-0.07; P < .01). Spearman's correlation R-value was 0.51. This positive correlation persisted in risk-adjusted multivariable linear regression. Each 1% increase in Society of Thoracic Surgeons risk score was associated with an added $3000 in hospital charges. This is the first study to show that increasing Society of Thoracic Surgeons risk score predicts greater charges after aortic valve replacement. As competing therapies, such as percutaneous valve replacement, emerge to

  8. Outcome of aortic valve replacement for active infective endocarditis in patients on chronic hemodialysis.

    PubMed

    Dohmen, Pascal M; Binner, Christian; Mende, Meinhart; Bakhtiary, Farhad; Etz, Christian; Pfannmüller, Bettina; Davierwala, Piroze; Borger, Michael A; Misfeld, Martin; Mohr, Friedrich W

    2015-02-01

    The high risk of morbidity and mortality for patients on hemodialysis who are undergoing cardiac surgery is increased for those with active infective endocarditis (AIE). This retrospective observational single-center study evaluated the impact of chronic hemodialysis on the outcome of aortic valve replacement in patients with aortic AIE. Data were retrospectively collected for consecutive patients undergoing aortic valve surgery for AIE diagnosed according to modified Duke criteria between October 1994 and January 2011. Characteristics and outcomes of patients receiving preoperative chronic hemodialysis were analyzed. Aortic valve AIE was present in 992 patients. Forty-five (4.5%) of the aortic valve AIE patients were receiving long-term hemodialysis preoperatively, 19 of whom (42.2%) had diabetes mellitus. Mean logistic EuroSCORE was 64.2% ± 32.2%. Twenty-four preoperative septic emboli were found in 15 patients. Results of microbiologic cultures were positive in 36 patients, with the major causative organisms identified as Staphylococcus aureus (n = 17) and Enterococcus faecalis (n = 10). Isolated aortic valve replacement was performed in 19 patients (42.2%), and 26 patients (57.8%) underwent concomitant procedures. The mean follow-up was 5.3 ± 5.2 years (range, 0.1 to 17.1 years). Postoperative complications occurred in 30 patients (66.7%). Nineteen patients (42.2%) died within 30 days of surgery, which in 8 patients was attributable to a cardiac cause. In patients receiving chronic hemodialysis who undergo aortic valve replacement for acute AIE, postoperative mortality is high, especially in patients undergoing aortic root replacement or culture-negative AIE. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. The impact of the metabolic syndrome on the outcome after aortic valve replacement.

    PubMed

    Tadic, Marijana; Vukadinovic, Davor; Cvijanovic, Dane; Celic, Vera; Kocica, Mladen; Putnik, Svetozar; Ivanovic, Branislava

    2014-10-01

    The aim of this study was to examine the influence of the metabolic syndrome on the left ventricular geometry as well as on the early and mid-time outcome in patients with aortic stenosis who underwent aortic valve replacement. The study included 182 patients who underwent aortic valve replacement due to aortic stenosis. The metabolic syndrome was defined by the presence of at least three AHA-NHLB (American Heart Association/National Heart, Lung and Blood Institute) criteria. All the patients were followed for at least 2 years after the surgery. The metabolic syndrome did not influence the severity of aortic stenosis (mean gradient and aortic valve area). However, the metabolic syndrome was associated with the reduced prevalence of the normal left ventricular geometry and the increased risk of concentric left ventricular hypertrophy in patients with aortic stenosis. Among the metabolic syndrome criteria, only increased blood pressure was simultaneously associated with the short-term and mid-term outcome, independently of other risk factors. Increased fasting glucose level was an independent predictor of the only 30-day outcome after the valve replacement. The metabolic syndrome and left ventricular hypertrophy were, independently of hypertension and diabetes, associated with the 30-day outcome, as well as incidence of major cerebrovascular and cardiovascular events in the 2-year postoperative period. The metabolic syndrome does not change severity of the aortic stenosis, but significantly impacts the left ventricular remodeling in these patients. The metabolic syndrome and left ventricular hypertrophy, irrespective of hypertension and diabetes, are predictors of the short-term and mid-term outcome of patients with aortic stenosis who underwent aortic valve replacement.

  10. Mitral-valve repair versus replacement for severe ischemic mitral regurgitation.

    PubMed

    Acker, Michael A; Parides, Michael K; Perrault, Louis P; Moskowitz, Alan J; Gelijns, Annetine C; Voisine, Pierre; Smith, Peter K; Hung, Judy W; Blackstone, Eugene H; Puskas, John D; Argenziano, Michael; Gammie, James S; Mack, Michael; Ascheim, Deborah D; Bagiella, Emilia; Moquete, Ellen G; Ferguson, T Bruce; Horvath, Keith A; Geller, Nancy L; Miller, Marissa A; Woo, Y Joseph; D'Alessandro, David A; Ailawadi, Gorav; Dagenais, Francois; Gardner, Timothy J; O'Gara, Patrick T; Michler, Robert E; Kron, Irving L

    2014-01-02

    Ischemic mitral regurgitation is associated with a substantial risk of death. Practice guidelines recommend surgery for patients with a severe form of this condition but acknowledge that the supporting evidence for repair or replacement is limited. We randomly assigned 251 patients with severe ischemic mitral regurgitation to undergo either mitral-valve repair or chordal-sparing replacement in order to evaluate efficacy and safety. The primary end point was the left ventricular end-systolic volume index (LVESVI) at 12 months, as assessed with the use of a Wilcoxon rank-sum test in which deaths were categorized below the lowest LVESVI rank. At 12 months, the mean LVESVI among surviving patients was 54.6±25.0 ml per square meter of body-surface area in the repair group and 60.7±31.5 ml per square meter in the replacement group (mean change from baseline, -6.6 and -6.8 ml per square meter, respectively). The rate of death was 14.3% in the repair group and 17.6% in the replacement group (hazard ratio with repair, 0.79; 95% confidence interval, 0.42 to 1.47; P=0.45 by the log-rank test). There was no significant between-group difference in LVESVI after adjustment for death (z score, 1.33; P=0.18). The rate of moderate or severe recurrence of mitral regurgitation at 12 months was higher in the repair group than in the replacement group (32.6% vs. 2.3%, P<0.001). There were no significant between-group differences in the rate of a composite of major adverse cardiac or cerebrovascular events, in functional status, or in quality of life at 12 months. We observed no significant difference in left ventricular reverse remodeling or survival at 12 months between patients who underwent mitral-valve repair and those who underwent mitral-valve replacement. Replacement provided a more durable correction of mitral regurgitation, but there was no significant between-group difference in clinical outcomes. (Funded by the National Institutes of Health and the Canadian Institutes of

  11. Aortic valve replacement during acute rheumatic fever.

    PubMed Central

    Khan, A; Chi, S; Gonzalez-Lavin, L

    1978-01-01

    Emergency aortic valve replacement was performed during an attack of acute rheumatic fever in a 12-year-old black boy. He had an uneventful recovery and has remained asymptomatic 27 months after operation. In the light of this experience and that of others, one might conclude that the decision to operate on these patients should be based on the severity of the haemodynamic derangement rather than on the state of activity in the rheumatic process. Images PMID:687481

  12. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    PubMed

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  13. PVR/CD155 Ala67Thr Mutation and Cleft Lip/Palate.

    PubMed

    Vieira, Alexandre R; Letra, Ariadne; Silva, Renato M; Granjeiro, Jose M; Shimizu, Takehiko; Poletta, Fernando A; Mereb, Juan C; Castilla, Eduardo E; Orioli, Iêda M

    2018-03-01

    The 19q13 locus has been linked to cleft lip and palate by our group and independently by others. Here we fine mapped the region in an attempt to identify an etiological variant that can explain cleft lip and palate occurrence. A total of 2739 individuals born with cleft lip and palate, related to individuals born with cleft lip and palate, and unrelated were studied. We used linkage and association approaches to fine map the interval between D19S714 and D19S433 and genotypes were defined by the use of TaqMan chemistry. We confirmed our previous findings that markers in PVR/CD155 are associated with cleft lip and palate. We studied the mutation Ala67Thr further and calculated its penetrance. We also attempted to detect PVR/CD155 expression in human whole saliva. Our results showed that markers in PVR/CD155 are associated with cleft lip and palate and the penetrance of the Ala67Thr is very low (between 1% and 5%). We could not detect PVR/CD155 expression in adult human whole saliva and PVR/CD155 possibly interacts with maternal infection to predispose children to cleft lip only.

  14. Comparison of acute elastic recoil between the SAPIEN-XT and SAPIEN valves in transfemoral-transcatheter aortic valve replacement.

    PubMed

    Garg, Aatish; Parashar, Akhil; Agarwal, Shikhar; Aksoy, Olcay; Hammadah, Muhammad; Poddar, Kanhaiya Lal; Puri, Rishi; Svensson, Lars G; Krishnaswamy, Amar; Tuzcu, E Murat; Kapadia, Samir R

    2015-02-15

    The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.

  15. Repair or Replacement for Isolated Tricuspid Valve Pathology? Insights from a Surgical Analysis on Long-Term Survival

    PubMed Central

    Farag, Mina; Arif, Rawa; Sabashnikov, Anton; Zeriouh, Mohamed; Popov, Aron-Frederik; Ruhparwar, Arjang; Schmack, Bastian; Dohmen, Pascal M.; Szabó, Gábor; Karck, Matthias; Weymann, Alexander

    2017-01-01

    Background Long-term follow-up data concerning isolated tricuspid valve pathology after replacement or reconstruction is limited. Current American Heart Association guidelines equally recommend repair and replacement when surgical intervention is indicated. Our aim was to investigate and compare operative mortality and long-term survival in patients undergoing isolated tricuspid valve repair surgery versus replacement. Material/Methods Between 1995 and 2011, 109 consecutive patients underwent surgical correction of tricuspid valve pathology at our institution for varying structural pathologies. A total of 41 (37.6%) patients underwent tricuspid annuloplasty/repair (TAP) with or without ring implantation, while 68 (62.3%) patients received tricuspid valve replacement (TVR) of whom 36 (53%) were mechanical and 32 (47%) were biological prostheses. Results Early survival at 30 days after surgery was 97.6% in the TAP group and 91.1% in the TVR group. After 6 months, 89.1% in the TAP group and 87.8% in the TVR group were alive. In terms of long-term survival, there was no further mortality observed after one year post surgery in both groups (Log Rank p=0.919, Breslow p=0.834, Tarone-Ware p=0.880) in the Kaplan-Meier Survival analysis. The 1-, 5-, and 8-year survival rates were 85.8% for TAP and 87.8% for TVR group. Conclusions Surgical repair of the tricuspid valve does not show survival benefit when compared to replacement. Hence valve replacement should be considered generously in patients with reasonable suspicion that regurgitation after repair will reoccur. PMID:28236633

  16. Reoperations after tricuspid valve repair: re-repair versus replacement

    PubMed Central

    Hwang, Ho Young; Kim, Kyung-Hwan; Kim, Ki-Bong

    2016-01-01

    Background Data demonstrating results of reoperation after initial tricuspid valve repair are scarce. We evaluated outcomes of tricuspid reoperations after tricuspid valve repair and compared the results of tricuspid re-repair with those of tricuspid valve replacement (TVR). Methods From 1994 to 2012, 53 patients (56±15 years, male:female =14:39) underwent tricuspid reoperations due to recurrent tricuspid regurgitation (TR) after initial repair. Twenty-two patients underwent tricuspid re-repair (TAP group) and 31 patients underwent TVR (TVR group). Results Early mortality occurred in 6 patients (11%). Early mortality and incidence of postoperative complications were similar between the 2 groups. There were 14 cases of late mortality including 9 cardiac deaths. Five- and 10-year free from cardiac death rates were 82% and 67%, respectively, without any intergroup difference. Recurrent TR (> moderate) developed in 6 TAP group patients and structural valve deterioration occurred in 1 TVR group patient (P=0.002). Isolated tricuspid valve surgery (P=0.044) and presence of atrial fibrillation during the follow-up (P=0.051) were associated with recurrent TR after re-repair. However, the overall tricuspid valve-related event rates were similar between the 2 groups with 5- and 10-year rates of 61% and 41%, respectively. Conclusions Tricuspid valve reoperation after initial repair resulted in high rates of operative mortality and complications. Long-term event-free rate was similar regardless of the type of surgery. However, great care might be needed when performing re-repair in patients with atrial fibrillation and those who had isolated tricuspid valve disease due to high recurrence of TR after re-repair. PMID:26904221

  17. Prosthetic valve sparing aortic root replacement: an improved technique.

    PubMed

    Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G

    2008-10-01

    We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.

  18. Longevity after aortic root replacement: is the mechanically valved conduit really the gold standard for quinquagenarians?

    PubMed

    Etz, Christian D; Girrbach, Felix F; von Aspern, Konstantin; Battellini, Roberto; Dohmen, Pascal; Hoyer, Alexandro; Luehr, Maximilian; Misfeld, Martin; Borger, Michael A; Mohr, Friedrich W

    2013-09-10

    The choice of the best conduit for root/ascending disease and its impact on longevity remain controversial in quinquagenarians. A total of 205 patients (men=155) between 50 and 60 years (mean, 55.7 ± 2.9 years) received either a stentless porcine xenoroot (n=78) or a mechanically valved composite prosthesis (n=127) between February 1998 and July 2011. Of these, 166 patients underwent root replacement for aneurysmal disease (porcine: 39% [n=65]; mechanical: 61% [n=101]; P=0.5), 25 for acute type A aortic dissection (porcine: 32% [n=8]; mechanical: 68% [n=17]; P=0.51), and 14 for endocarditis/iatrogenic injury involving the aortic root (6.4% [n=5] versus 7.1% [n=9]; P=1.0). The predominant aortic valve pathology was stenosis in 19% (n=38), regurgitation in 50% (n=102), combined valvular dysfunction in 26% (n=54), and normal aortic valve function in 5% (n=11). Concomitant procedures included coronary artery bypass grafting (13%), mitral valve repair (7%), and partial/complete arch replacement (12%/4%), with no significant differences between porcine and mechanical root replacement. Overall hospital mortality was 7.3%, with no difference between the 2 types of valve prostheses (7.7% for porcine and 7.1% for mechanical root replacement; P=1.0). Follow-up averaged 5.4 ± 3.7 years (1096 patient-years) and was 100% complete. Freedom from aorta-related reoperation at 12 years was not statistically different between the groups (porcine: 94.9% versus mechanical: 96.1%; P=0.73). Survival was equivalent between both groups, with a 5-year survival of 86 ± 3% (porcine: 88 ± 4%; mechanical: 85 ± 3%; P=0.96) and a 10-year survival of 76% (porcine: 80 ± 7%; mechanical: 75 ± 5%; P=0.84). The linearized mortality rate was 3.1%/patient-year (porcine: 2.9%/patient-year; mechanical: 3.2%/patient-year). In quinquagenerians, long-term survival after stentless porcine xenograft aortic root replacement is equivalent to that after a mechanical Bentall procedure. These results bring

  19. Incidence, Timing, and Predictors of Valve Hemodynamic Deterioration After Transcatheter Aortic Valve Replacement: Multicenter Registry.

    PubMed

    Del Trigo, Maria; Muñoz-Garcia, Antonio J; Wijeysundera, Harindra C; Nombela-Franco, Luis; Cheema, Asim N; Gutierrez, Enrique; Serra, Vicenç; Kefer, Joelle; Amat-Santos, Ignacio J; Benitez, Luis M; Mewa, Jumana; Jiménez-Quevedo, Pilar; Alnasser, Sami; Garcia Del Blanco, Bruno; Dager, Antonio; Abdul-Jawad Altisent, Omar; Puri, Rishi; Campelo-Parada, Francisco; Dahou, Abdellaziz; Paradis, Jean-Michel; Dumont, Eric; Pibarot, Philippe; Rodés-Cabau, Josep

    2016-02-16

    Scarce data exist on the incidence of and factors associated with valve hemodynamic deterioration (VHD) after transcatheter aortic valve replacement (TAVR). This study sought to determine the incidence, timing, and predictors of VHD in a large cohort of patients undergoing TAVR. This multicenter registry included 1,521 patients (48% male; 80 ± 7 years of age) who underwent TAVR. Mean echocardiographic follow-up was 20 ± 13 months (minimum: 6 months). Echocardiographic examinations were performed at discharge, at 6 to 12 months, and yearly thereafter. Annualized changes in mean gradient (mm Hg/year) were calculated by dividing the difference between the mean gradient at last follow-up and the gradient at discharge by the time between examinations. VHD was defined as a ≥10 mm Hg increase in transprosthetic mean gradient during follow-up compared with discharge assessment. The overall mean annualized rate of transprosthetic gradient progression during follow-up was 0.30 ± 4.99 mm Hg/year. A total of 68 patients met criteria of VHD (incidence: 4.5% during follow-up). The absence of anticoagulation therapy at hospital discharge (p = 0.002), a valve-in-valve (TAVR in a surgical valve) procedure (p = 0.032), the use of a 23-mm valve (p = 0.016), and a greater body mass index (p = 0.001) were independent predictors of VHD. There was a mild but significant increase in transvalvular gradients over time after TAVR. The lack of anticoagulation therapy, a valve-in-valve procedure, a greater body mass index, and the use of a 23-mm transcatheter valve were associated with higher rates of VHD post-TAVR. Further prospective studies are required to determine whether a specific antithrombotic therapy post-TAVR may reduce the risk of VHD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Dynamic Course of Serratia marcescens Pulmonic Valve Endocarditis Resulting in Submassive PE and Valve Replacement.

    PubMed

    Meyer, Chloe Grace; Vacek, Thomas Paul; Bansal, Amit; Gurujal, Ravi; Parikh, Analkumar

    2018-01-01

    This report illustrates a case of a 42-year-old male with a history of intravenous drug abuse who presented with septic shock. Diagnostic studies, including a transthoracic echocardiogram, chest computed tomography angiography, transesophageal echocardiogram, and blood cultures ultimately revealed Serratia marcescens pulmonic valve infective endocarditis that was treated with intravenous antibiotics. In addition to the rare form of endocarditis and bacterium involved, this case brings into awareness the dynamic nature of the hospital course that requires vigilance in responding to hypotensive episodes for consideration of pulmonary embolism. Surgical valve replacement was opted for due to such a complication in addition to the large size of the vegetation, 2.5 cm.

  1. Aortic valve replacement using continuous suture technique in patients with aortic valve disease.

    PubMed

    Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku

    2013-08-01

    The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

  2. Long-term survival, valve durability, and reoperation for 4 aortic root procedures combined with ascending aorta replacement.

    PubMed

    Svensson, Lars G; Pillai, Saila T; Rajeswaran, Jeevanantham; Desai, Milind Y; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Thamilarasan, Maran; Roselli, Eric E; Pettersson, Gösta B; Gillinov, A Marc; Navia, Jose L; Smedira, Nicholas G; Sabik, Joseph F; Lytle, Bruce W; Blackstone, Eugene H

    2016-03-01

    To evaluate long-term results of aortic root procedures combined with ascending aorta replacement for aneurysms, using 4 surgical strategies. From January 1995 to January 2011, 957 patients underwent 1 of 4 aortic root procedures: valve preservation (remodeling or modified reimplantation, n = 261); composite biologic graft (n = 297); composite mechanical graft (n = 156); or allograft root (n = 243). Seven deaths occurred (0.73%), none after valve-preserving procedures, and 13 strokes (1.4%). Composite grafts exhibited higher gradients than allografts or valve preservation, but the latter 2 exhibited more aortic regurgitation (2.7% biologic and 0% mechanical composite grafts vs 24% valve-preserving and 19% allografts at 10 years). Within 2 to 5 years, valve preservation exhibited the least left ventricular hypertrophy, allograft replacement the greatest; however, valve preservation had the highest early risk of reoperation, allograft replacement the lowest. Patients receiving allografts had the highest risk of late reoperation (P < .05), and those receiving composite mechanical grafts and valve preservation had the lowest. Composite bioprosthesis patients had the highest risk of late death (57% at 15 years vs 14%-26% for the remaining procedures, P < .0001), because they were substantially older and had more comorbidities (P < .0001). These 4 aortic root procedures, combined with ascending aorta replacement, provide excellent survival and good durability. Valve-preserving and allograft procedures have the lowest gradients and best ventricular remodeling, but they have more late regurgitation, and likely, less risk of valve-related complications, such as bleeding, hemorrhage, and endocarditis. Despite the early risk of reoperation, we recommend valve-preserving procedures for young patients when possible. Composite bioprostheses are preferable for the elderly. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights

  3. Is mitral valve repair superior to replacement for chronic ischemic mitral regurgitation with left ventricular dysfunction?

    PubMed Central

    2010-01-01

    Background This study was undertaken to compare mitral valve repair and replacement as treatments for ischemic mitral regurgitation (IMR) with left ventricular dysfunction (LVD). Specifically, we sought to determine whether the choice of mitral valve procedure affected survival, and discover which patients were predicted to benefit from mitral valve repair and which from replacement. Methods A total of 218 consecutive patients underwent either mitral valve repair (MVP, n = 112) or mitral valve replacement (MVR, n = 106). We retrospectively reviewed the clinical material, operation methods, echocardiography check during operation and follow-up. Patients details and follow-up outcomes were compared using multivariate and Kaplan-Meier analyses. Results No statistical difference was found between the two groups in term of intraoperative data. Early mortality was 3.2% (MVP 2.7% and MVR 3.8%). At discharge, Left ventricular end-systolic and end-diastolic diameter and left ventricular ejection fraction (LVEF) were improved more in the MVP group than MVR group (P < 0.05), however, in follow-up no statistically significant difference was observed between the MVR and MVP group (P > 0.05). Follow-up mitral regurgitation grade was significantly improved in the MVR group compared with the MVP group (P < 0.05). The Kaplan-Meier survival estimates at 1, 3, and 5 years were simlar between MVP and MVR group. Logistic regression revealed poor survival was associated with old age(#75), preoperative renal insufficiency and low left ventricular ejection fraction (< 30%). Conclusion Mitral valve repair is the procedure of choice in the majority of patients having surgery for severe ischemic mitral regurgitation with left ventricular dysfunction. Early results of MVP treatment seem to be satisfactory, but several lines of data indicate that mitral valve repair provided less long-term benefit than mitral valve replacement in the LVD patients. PMID:21059216

  4. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    PubMed

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p < 0.001). Thoracic aortic aneurysms were significantly more likely to be diagnosed in late follow-up in patients with Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p < 0.001). Patients with Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p < 0.001). The much higher long-term rates of aortic complications after AVR observed in patients with Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities

  5. Posterior leaflet preservation during mitral valve replacement for rheumatic mitral stenosis.

    PubMed

    Djukić, P L; Obrenović-Kirćanski, B B; Vranes, M R; Kocica, M J; Mikić, A Dj; Velinović, M M; Kacar, S M; Kovacević, N S; Parapid, B J

    2006-01-01

    Mitral valve replacement with posterior leaflet preservation was shown beneficial for postoperative left vetricular (LV) performance in patients with mitral regurgitation. Some authors find it beneficial even for the long term LV function. We investigated a long term effect of this technique in patients with rheumatic mitral stenosis. We studied 20 patents with mitral valve replacement due to rheumatic mitral stenosis, in the period from January 1988 to December 1989. In group A (10 patients) both leaflets and coresponding chordal excision was performed, while in group B (10 patients) the posterior leaflet was preserved. In all patients a Carbomedics valve was inserted. We compared clinical pre and postoperative status, as well as hemodynamic characteristics of the valve and left ventricle in both groups. Control echocardiographyc analysis included: maximal (PG) and mean (MG) gradients; effective valve area (AREA); telediastolic (TDV) and telesystolic (TSV) LV volume; stroke volume (SV); ejection fraction (EF); fractional shortening (FS) and segmental LV motion. The mean size of inserted valve was 26.6 in group A and 27.2 in group B. Hemodynamic data: PG (10.12 vs 11.1); MG (3.57 vs 3.87); AREA (2.35 vs 2.30); TDV 126.0 vs 114.5); TSV (42.2 vs 36.62); SV (83.7 vs 77.75); EF (63.66 vs 67.12); FS (32.66 vs 38.25). Diaphragmal segmental hypokinesis was evident in one patient from group A and in two patients from group B. In patients with rheumatic stenosis, posterior leaflet preservation did not have increased beneficial effect on left ventricular performance during long-term follow-up. An adequate posterior leaflet preservation does not change hemodynamic valvular characteristics even after long-term follow-up.

  6. Aortic valve replacement and concomitant right coronary artery bypass grafting performed via a right minithoracotomy approach.

    PubMed

    Mihos, Christos G; Santana, Orlando; Pineda, Andres M; La Pietra, Angelo; Lamelas, Joseph

    2014-01-01

    We present our experience of concomitant right coronary artery bypass grafting (CABG) and aortic valve replacement performed via a right minithoracotomy in patients with coronary lesions not amenable to percutaneous intervention. A total of 17 patients underwent concomitant aortic valve replacement and right CABG between April 2008 and July 2013. A 5- to 6-cm minithoracotomy incision was made over the right second or third intercostal space, and the costochondral cartilage was transected. A saphenous vein bypass to the right coronary artery was then performed, initiating the anastomosis from the toe of the graft. Subsequently, the aortic valve was replaced using standard techniques. There were 6 men and 11 women. The median European System for Cardiac Operative Risk Evaluation II score mortality risk was 5% [interquartile range (IQR), 2%-8%]. The mean (SD) age was 77 (10) years, the left ventricular ejection fraction was 59% (8%), and the New York Heart Association functional class was 2.4 (0.8). One patient had a history of CABG. The mean (SD) cardiopulmonary bypass time was 168 (57) minutes, and the aortic cross-clamp time was 133 (36) minutes. Three patients underwent concomitant mitral valve surgery (replacement, 2; repair, 1). The median intensive care unit and hospital lengths of stay were 47 hours (IQR, 24-90) and 9 days (IQR, 5-13), respectively. There was one reoperation for bleeding, and there was one postoperative stroke. All patients were alive at a mean (SD) follow-up of 2 (1.1) years. Aortic valve replacement with concomitant CABG performed via a right minithoracotomy approach is feasible.

  7. Hemodynamic deterioration after aortic valve replacement in a patient with mixed systemic amyloidosis.

    PubMed

    Seki, Tatsuya; Hattori, Atsuo; Yoshida, Toshihito

    2017-08-01

    We report a case of hemodynamic deterioration after aortic valve replacement in a patient with mixed systemic amyloidosis. A 77-year-old male with severe aortic valve stenosis and 19 years hemodialysis underwent aortic valve replacement. Postoperatively, the patient died of hemodynamic deterioration. Autopsy findings showed massive, whole-body edema and mixed systemic amyloidosis (dialysis-related and AA amyloidosis). Clinical and autopsy findings implied that hemodynamic deterioration was caused by increased vascular permeability. The amyloid deposit to the vessel causes inflammatory changes and increases vascular permeability. Mixed systemic amyloidosis occurs very rarely and could increases vascular permeability even more than each single type of amyloidosis. Systemic amyloidosis may be a risk factor for hemodynamic deterioration after cardiac surgery. Patients with longtime hemodialysis and a history associated with dialysis-related amyloidosis would have at least single systemic amyloidosis, which should be considered a contraindication to cardiac surgery with cardiopulmonary bypass.

  8. Percutaneous closure of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement.

    PubMed

    Nakamura, Kenta; Passeri, Jonathan J; Inglessis-Azuaje, Ignacio

    2017-07-01

    We report a case of acute aorto-right ventricular fistula following transcatheter bicuspid aortic valve replacement and subsequent percutaneous closure. The diagnosis and treatment of this rare complication is illustrated through multi-modality imaging. We hypothesize that the patient's heavily calcified bicuspid aortic valve anatomy led to asymmetric deployment of the transcatheter aortic valve replacement (TAVR) prosthesis, traumatizing the right sinus of Valsalva at the distal edge of the TAVR stent and ultimately fistulized to the right ventricle. The patient acutely decompensated with heart failure five days after TAVR and underwent emergent intervention. The aorto-right ventricular fistula was closed using an 18-mm septal occluder device with marked clinical recovery. Transcatheter closure is a viable treatment option for acute aorto-right ventricular fistula. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    PubMed

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  10. Aortic cusp extension valvuloplasty with or without tricuspidization in children and adolescents: long-term results and freedom from aortic valve replacement.

    PubMed

    Polimenakos, Anastasios C; Sathanandam, Shyam; Elzein, Chawki; Barth, Mary J; Higgins, Robert S D; Ilbawi, Michel N

    2010-04-01

    Aortic cusp extension valvuloplasty is increasingly used in the management of children and adolescents with aortic stenosis or regurgitation. The durability of this approach and the freedom from valve replacement are not well defined. A study was undertaken to investigate outcomes. From July 1987 to November 2008, 142 patients aged less than 19 years underwent aortic cusp extension valvuloplasty in the form of pericardial cusp extension and tricuspidization (when needed). Three patients with truncus arteriosus and severe truncal valve insufficiency were excluded. From the available follow-up data of 139 patients, 50 had bicuspid aortic valves, 40 had congenital aortic valve stenosis, 41 had combined congenital aortic valve stenosis/insufficiency, and 8 had other diagnoses. Median follow-up was 14.4 years (0.1-21.4). Long-term mortality and freedom from aortic valve replacement were studied. There were no early, intermediate, or late deaths. Z-values of left ventricular end-diastolic dimension, aortic annulus, aortic sinus diameter, and sinotubular junction diameter before aortic valve replacement were 4.2 +/- 3.11, 2.3 +/- 1.25, 4.4 +/- 1.23, and 1.84 +/- 1.28, respectively. During the follow-up period, 64 patients underwent aortic valve reinterventions. The Ross procedure was performed in 32 of 139 patients (23%) undergoing aortic cusp extension valvuloplasty. Other aortic valve replacements were undertaken after 16 aortic cusp extension valvuloplasties (11.5%). Freedom from a second aortic cusp extension valvuloplasty or aortic valve replacement at 18 years was 82.1% +/- 4.2% and 60.0% +/- 7.2%, respectively. Aortic cusp extension valvuloplasty is a safe and effective surgical option with excellent survival and good long-term outcomes in children and adolescents. The procedure provides acceptable durability and satisfactory freedom from aortic valve replacement. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  11. Illness Perception Profiles and Their Association with 10-Year Survival Following Cardiac Valve Replacement.

    PubMed

    Crawshaw, Jacob; Rimington, Helen; Weinman, John; Chilcot, Joseph

    2015-10-01

    The aim of the present study was to examine whether profiles of illness perceptions are associated with 10-year survival following cardiac valve replacement surgery. Illness perceptions were evaluated in 204 cardiac patients awaiting first-time valve replacement and again 1 year post-operatively using cluster analysis. All-cause mortality was recorded over a 10-year period. At 1 year, 136 patients were grouped into one of four profiles (stable positive, stable negative, changed from positive to negative, changed from negative to positive). The median follow-up was 3063 days (78 deaths). After controlling for clinical covariates, including markers of function, patients who changed illness perceptions from positive to negative beliefs 1 year post-surgery had an increased mortality risk (hazard ratio (HR) = 3.2, 95% confidence interval (CI) 1.2-8.3, p = .02) compared to patients who held positive stable perceptions. Following cardiac valve replacement, developing negative illness perceptions over the first post-operative year predicts long-term mortality. Early screening and intervention to alter this pattern of beliefs may be beneficial.

  12. Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu

    Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less

  13. The valve choice in tricuspid valve replacement: 25 years of experience.

    PubMed

    Van Nooten, G J; Caes, F L; François, K J; Taeymans, Y; Primo, G; Wellens, F; Leclerq, J L; Deuvaert, F E

    1995-01-01

    This study reviews 146 consecutive patients who underwent tricuspid valve replacement (TVR) with 69 bioprostheses (porcine and bovine pericardial) and 77 mechanical ball, disc or bileaflet valves between 1967 and 1987. The mean age was 51.4 +/- 12.1 years. Preoperatively, 97% were in New York Heart Association (NYHA) functional class III or more and over 40% had undergone previous cardiac surgery. Hospital mortality was high (16.1%). Incremental risk factors for hospital death were preoperative icterus (P < 0.01), hepatomegaly (P = 0.02), NYHA functional class IV (P = 0.02) and male sex (P = 0.04) (univariate analysis). Ninety-eight percent of the hospital survivors were followed up for a mean of 92 months. Cumulative follow-up added up to 955 patient-years. There were 70 late deaths. The actuarial survival rate was 74% at 60 months and less than 25% at 14 years. Incremental risk factors for late death indicated by univariate analysis were the type of tricuspid prosthesis (Smel-off-Cutter and Kay-Shiley prostheses) (P = 0.04), the type of operative myocardial protection (normothermia and coronary perfusion) (P = 0.05) and preoperative NYHA functional class IV (P = 0.05). We conclude that TVR carries a high operative risk and poor long-term survival, both influenced by preoperative and perioperative variables. Bearing in mind the poor prognosis for TVR, we prefer a large-sized bioprosthesis, in view of its initial good durability and low risk of valve-related events. However, in patients with good life expectancy, a bileaflet mechanical prosthesis may be an acceptable alternative.

  14. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement

    PubMed Central

    Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed. PMID:29552039

  16. Cold crystalloid versus warm blood cardioplegia in patients undergoing aortic valve replacement.

    PubMed

    Nardi, Paolo; Vacirca, Sara R; Russo, Marco; Colella, Dionisio F; Bassano, Carlo; Scafuri, Antonio; Pellegrino, Antonio; Melino, Gerry; Ruvolo, Giovanni

    2018-03-01

    Myocardial protection techniques during cardiac arrest have been extensively investigated in the clinical setting of coronary revascularization. Fewer studies have been carried out of patients affected by left ventricular hypertrophy, where the choice of type and temperature of cardioplegia remain controversial. We have retrospectively investigated myocardial injury and short-term outcome in patients undergoing aortic valve replacement plus or minus coronary artery bypass grafting with using cold crystalloid cardioplegia (CCC) or warm blood cardioplegia (WBC). From January 2015 to October 2016, 191 consecutive patients underwent aortic valve replacement plus or minus coronary artery bypass grafting in normothermic cardiopulmonary bypass. Cardiac arrest was obtained with use of intermittent antegrade CCC group (n=32) or WBC group (n=159), according with the choice of the surgeon. As compared with WBC group, in CCC group creatine-kinase-MB (CK-MB), cardiac troponin I (cTnI), aspartate aminotransferase (AST) release, and their peak levels, were lower during each time points of evaluation, with the greater statistically significant difference at time 0 (P<0.05, for all comparisons). A time 0, CK-MB/CK ratio >10% was 5.9% in CCC group versus 7.8% in WBC group (P<0.0001). At time 0 CK-MB/CK ratio >10% in patients undergoing isolated aortic valve replacement was 6.0% in CCC group versus 8.0% in WBC group (P<0.01). No any difference was found in perioperative myocardial infarction (0% versus 3.8%), postoperative (PO) major complications (15.6% versus 16.4%), in-hospital mortality (3.1% versus 1.3%). In aortic valve surgery a significant decrease of myocardial enzymes release is observed in favor of CCC, but this difference does not translate into different clinical outcome. However, this study suggests that in presence of cardiac surgical conditions associated with significant left ventricular hypertrophy, i.e., the aortic valve disease, a better myocardial protection can

  17. Mitral annular calcification in patients undergoing aortic valve replacement for aortic valve stenosis.

    PubMed

    Takami, Yoshiyuki; Tajima, Kazuyoshi

    2016-02-01

    Limited data exis t on clinical relevance of aortic valve stenosis (AVS) and mitral annular calcification (MAC), although with similar pathophysiologic basis. We sought to reveal the prevalence of MAC and its clinical features in the patients undergoing aortic valve replacement (AVR) for AVS. We reviewed 106 consecutive patients who underwent isolated AVR from 2004 to 2010. Before AVR, CT scans were performed to identify MAC, whose severity was graded on a scale of 0-4, with grade 0 denoting no MAC and grade 4 indicating severe MAC. Echocardiography was performed before AVR and at follow-up over 2 years after AVR. MAC was identified in 56 patients with grade 1 (30 %), 2 (39 %), 3 (18 %), and 4 (13 %), respectively. Patients with MAC presented older age (72 ± 8 versus 66 ± 11 years), higher rate of dialysis-dependent renal failure (43 versus 4 %), and less frequency of bicuspid aortic valve (9 versus 36 %), when compared to those without MAC. No significant differences were seen in short- and mid-term mortality after AVR between the groups. In patients with MAC, progression of neither mitral regurgitation nor stenosis was observed at follow-up of 53 ± 23 months for 102 survivors, although the transmitral flow velocities were higher than in those without MAC. In conclusion, MAC represented 53 % of the patients undergoing isolated AVR for AVS, usually appeared in dialysis-dependent elder patients with tricuspid AVS. MAC does not affect adversely upon the survival, without progression of mitral valve disease, at least within 2 years after AVR.

  18. Percutaneous Transcatheter Mitral Valve Replacement: Patient-specific Three-dimensional Computer-based Heart Model and Prototyping.

    PubMed

    Vaquerizo, Beatriz; Theriault-Lauzier, Pascal; Piazza, Nicolo

    2015-12-01

    Mitral regurgitation is the most prevalent valvular heart disease worldwide. Despite the widespread availability of curative surgical intervention, a considerable proportion of patients with severe mitral regurgitation are not referred for treatment, largely due to the presence of left ventricular dysfunction, advanced age, and comorbid illnesses. Transcatheter mitral valve replacement is a promising therapeutic alternative to traditional surgical valve replacement. The complex anatomical and pathophysiological nature of the mitral valvular complex, however, presents significant challenges to the successful design and implementation of novel transcatheter mitral replacement devices. Patient-specific 3-dimensional computer-based models enable accurate assessment of the mitral valve anatomy and preprocedural simulations for transcatheter therapies. Such information may help refine the design features of novel transcatheter mitral devices and enhance procedural planning. Herein, we describe a novel medical image-based processing tool that facilitates accurate, noninvasive assessment of the mitral valvular complex, by creating precise three-dimensional heart models. The 3-dimensional computer reconstructions are then converted to a physical model using 3-dimensional printing technology, thereby enabling patient-specific assessment of the interaction between device and patient. It may provide new opportunities for a better understanding of the mitral anatomy-pathophysiology-device interaction, which is of critical importance for the advancement of transcatheter mitral valve replacement. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  19. [Short and long term results of aortic valve replacement in patients 80 years of age and older].

    PubMed

    Mortasawi, A; Gehle, S; Yaghmaie, M; Schröder, T; Ennker, I C; Rosendahl, U; Albert, A; Ennker, J

    2001-03-01

    Due to demographic changes in average life expectancy the age of patients undergoing cardiac surgery is increasing as well. We have reviewed the short- and long-term outcome in patients over 80 years of age after aortic valve replacement with or without concomitant coronary grafting. From 1.1.1995 until 31.12.1999, 126 patients (93 women, 33 men between 80 and 89 years, 82.8 +/- 2.4) underwent aortic valve replacement. 64 patients (group A) received isolated valve replacement, 62 (group B) underwent myocardial revascularization as well. The 30-day hospital mortality rate was 6.3% for group A and 14.5% for group B. The follow-up time ranged between 3 and 63 months (32 +/- 16). None of the patients had to be reoperated for prosthetic valve dysfunction or endocarditis. Bleeding complications due to anticoagulation therapy were observed by one patient from group A 3 years after the operation. Of the 15 deaths during the follow-up period seven (47%) were cardiac in nature and two (13%) related to stroke. Acturial survival rates for group A were 89%, 85% and 77% at 1, 2 and 3 years, and for group B 76%, 72% and 70%. Permanent nursing care was not required 1 year after the operation by 100% of patients in group A (2 years: 98%, 3 years 95%) and by 100% of patients in group B (2 years: 93%, 3 years: 90%). At an interval of 1 year after the operation 96% of patients in group A had not been hospitalized as a result of cardiac disorders (2 years: 96%, 3 years: 94%). The rates for group B were 88%, 81% and 75%. Compared with younger age groups, aortic valve replacement in patients 80 years of age and older is associated with a distinctly increased mortality and morbidity. However, our data suggest that considering the poor prognosis of conservative therapy of symptomatic aortic valve disease, functional status as well as life expectancy in this age group seem to be positively influenced by aortic valve replacement.

  20. Midterm results after aortic valve replacement with freehand stentless xenografts: a comparison of three prostheses.

    PubMed

    Luciani, G B; Bertolini, P; Vecchi, B; Mazzucco, A

    1998-06-01

    The ideal substitute for the diseased aortic valve is yet to be found. For the assessment and comparison of the midterm results after aortic valve replacement with three different types of freehand stentless xenografts, all patients who underwent the operation between October 1992 and April 1997 were reviewed. Of 231 patients undergoing aortic valve replacement, 106 patients (group 1) were given the Biocor PSB (Biocor Industria e Pesquisa Ltda, Belo Horizonte, MG, Brazil); 76 patients (group 2) were given the Toronto SPV (St. Jude Medical, Inc., St. Paul, Minn.), and 49 patients (group 3) were given the O'Brien-Angell valve (Bravo Cardiovascular model 300, Cryolife, Inc., Marietta, Ga.). The first two xenografts require inflow and outflow suturelines; the third xenograft needs a single-sutureline implantation. Mean age (70 +/- 6 years; 70 +/- 7 years; 72 +/- 9 years; p = 0.6), prevalence of male sex (56 patients, 53%; 37 patients, 49%; 22 patients, 45%; p = 0.7), of aortic stenosis (72 patients, 68%; 54 patients, 71%; 37 patients, 73%; p = 0.6), and need for associated procedures (51 patients, 48%; 30 patients, 40%; 21 patients, 43%; p = 0.1) were comparable among groups. Mean aortic crossclamp time was shorter in group 3 (96 +/- 24 minutes; 100 +/- 23 minutes; 88 +/- 25 minutes;p = 0.01). Early deaths were 3 of 106 (3%) in group 1, 2 of 76 (3%) in group 2, and 2 of 49 (4%) in group 3. Follow-up of survivors ranged from 1 to 54 months (mean 32 +/- 13 months). Survival at 4 years was 90% +/- 3% in group 1, 95% +/- 3% in group 2, 85% +/- 8% in group 3 (p = 0.3). At 4 years, freedom from valve-related events was 95% +/- 6%, 100%, 70% +/- 8% (p = 0.004), while freedom from valve deterioration was 99% +/- 1%, 100%, 73% +/- 8% (p = 0.001), in group 1, 2, and 3, respectively (p = 0.001). At follow-up, reintervention on the xenograft was necessary in one patient (endocarditis) in group 1, none in group 2, and six in group 3 (technical cause, group 3; valve tear, group 2

  1. Computerized system for the follow-up of patients with heart valve replacements.

    PubMed

    Bain, W H; Fyfe, I C; Rodger, R A

    1985-04-01

    A system is described which will accept, store, retrieve and analyze information on large numbers of patients who undergo valve replacement surgery. The purpose of the database is to yield readily available facts concerning the patient's clinical course, prosthetic valve function, length of survival, and incidence of complications. The system uses the Apple Macintosh computer, which is one of the current examples of small, desk-top microprocessors. The software for the input, editing and analysis programs has been written by a professional software writer in close collaboration with a cardiac surgeon. Its content is based on 8 years' experience of computer-based valve follow-up. The system is inexpensive and has proved easy to use in practice.

  2. Late-term results of mitral valve replacement with St. Jude Medical mechanical valve prosthesis: Samsun experience.

    PubMed

    Demirag, Mustafa Kemal; Keceligil, Hasan Tahsin; Kolbakir, Fersat

    2006-10-01

    We have reported the short- and long-term results of mitral valve replacement in this article. Mitral valve replacement was conducted in 276 patients in our clinic between January 1989 and March 2005. The youngest patient was 4 years old and the oldest patient was 74 years old. Mean age was 40.08 +/- 1.06 y. Of these patients, 41.3% were men and 58.7% were women. The reason for operation was mitral stenosis in 96 patients (34.78%), mitral insufficiency in 78 patients (29.26%) and mitral stenosis plus mitral insufficiency in 102 patients (36.96%). The aetiology of mitral valve lesions was acute rheumatic fever in 208 patients (75.36%). The aetiology of mitral valve lesions was degenerative in 37 patients (13.41%), ischaemic in 23 patients (8.33%) and congenital in 8 patients (2.9%). In the 5, 10 and 15-year periods, the actual survival rates were 87.64% +/- 2.02%, 83.35% +/- 2.38% and 68.19% +/- 5.63%, respectively. Thromboembolism was observed in 38 patients (13.77%). The rates of actual freedom from thromboembolism in the 5, 10 and 15-year periods were 93.08% +/- 1.53%, 88.48% +/- 1.99% and 81.06% +/- 3.43%, respectively. Of the 276 patients who had been observed for 15 years, 5 had (1.81%) valvular thrombosis. The rates of actual freedom from valvular thrombosis in the 5, 10 and 15-year periods were 98.89% +/- 0.64%, 98.04% +/- 0.87% and 98.04% +/- 0.87%, respectively. In the 15-year period, 23 patients (8.33%) had haemorrhage due to anti-coagulation. The rates of actual freedom from haemorrhage due to anti-coagulation in the 5, 10 and 15-year periods were 95.64% +/- 1.23%, 93.40% +/- 1.56% and 87.73% +/- 2.96%, respectively. Seven patients (2.54%) had prosthetic valvular endocarditis. The rates of actual freedom from endocarditis in the 5, 10 and 15-year periods were 98.51% +/- 0.74%, 97.60% +/- 0.97% and 97.01% +/- 1.13%, respectively. Nine patients (3.27%) were re-operated. The rates of actual freedom from re-operation in the 5, 10 and 15-year periods were 97

  3. Transcatheter Pulmonary Valve Replacement by Hybrid Approach Using a Novel Polymeric Prosthetic Heart Valve: Proof of Concept in Sheep

    PubMed Central

    Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen

  4. Comparison between transcatheter and surgical aortic valve replacement: a single-center experience.

    PubMed

    Silberman, Shuli; Abu Akr, Firas; Bitran, Daniel; Almagor, Yaron; Balkin, Jonathan; Tauber, Rachel; Merin, Ofer

    2013-07-01

    A comparison was made of the outcomes after transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (AVR) in high-risk patients. All patients aged > 75 years that underwent a procedure for severe aortic stenosis with or without coronary revascularization at the authors' institution were included in the study; thus, 64 patients underwent TAVI and 188 underwent AVR. Patients in the TAVI group were older (mean age 84 +/- 5 versus 80 +/- 4 years; p < 0.0001) and had a higher logistic EuroSCORE (p = 0.004). Six patients (9%) died during the procedure in the TAVI group, and 23 (12%) died in the AVR group (p = 0.5). Predictors for mortality were: age (p < 0.0001), female gender (p = 0.02), and surgical valve replacement (p = 0.01). Gradients across the implanted valves at one to three months postoperatively were lower in the TAVI group (p < 0.0001). Actuarial survival at one, two and three years was 78%, 64% and 64%, respectively, for TAVI, and 83%, 78% and 75%, respectively, for AVR (p = 0.4). Age was the only predictor for late mortality (p < 0.0001). TAVI patients were older and posed a higher predicted surgical risk. Procedural mortality was lower in the TAVI group, but mid-term survival was similar to that in patients undergoing surgical AVR. Age was the only predictor for late survival. These data support the referral of high-risk patients for TAVI.

  5. Emergency aortic valve replacement and Caesarian section in a primigravida with severe aortic stenosis: a case report.

    PubMed

    Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P

    2011-01-01

    Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).

  6. A 20-year study on treating childhood infective endocarditis with valve replacement in a single cardiac center in China.

    PubMed

    Xiao, Jian; Yin, Liang; Lin, Yiyun; Zhang, Yufeng; Wu, Lihui; Wang, Zhinong

    2016-07-01

    Children with infective endocarditis (IE) have to undergo valve replacement instead of valve repair in China due to severe valve damage. The present study is to review our experience on surgical treatment of children with IE in reference to the incidence, pathologic status, diagnosis, surgical strategies and outcomes. We reviewed 35 patients with a mean age of 13.7±2.2 years who were underwent valve replacement surgery for IE during the period from January 1993 to December 2013. Preoperative transthoracic echocardiographic (TTE) evaluation and transesophageal echocardiography during operation were performed in all patients. All the children underwent chart review and retrospective risk-hazard analysis. Among the patients surveyed congenital cardiac lesions were present in 15 (42.8%), rheumatic heart valve disease in 2 (5.7%) and previous heart surgery in 2 (5.7%). The median stay of intensive care unit was 6 days. Intraoperative findings showed that the endocarditis involved mostly the mitral and aortic valves (88.5%). Triple or quadruple valve involvement was found in one patient each. Ten-year freedom from IE-related death and re-intervention was 94.2% and 91.6%, respectively. Children undergoing surgery for IE frequently have advanced disease with embolic complications. Although valve replacement is not the primary option for pediatric IE, the rate of 5-year survival and freedom from re-operation was optimal prognostically. Pediatric physicians should pay attention to the common clinical features of IE so that the native valve is preserved well.

  7. Acute gastrointestinal bleeding following aortic valve replacement in a patient with Heyde's sindrome. Case report.

    PubMed

    De Palma, G D; Salvatori, F; Masone, S; Simeoli, I; Rega, M; Celiento, M; Persico, G

    2007-09-01

    A 58-year old man was admitted to the hospital because of melena. He had a 1-year history of mechanical aortic valve replacement and coronary stent placement because of myocardial infarction and he was taking warfarin and clopidogrel. Esophagogastroduodenoscopy and colonoscopy were negative for bleeding. Capsule endoscopy showed bleeding diffuse angiodysplasia of the small bowel. The patient was treated with octreotide 20 mg, at monthly interval. After 25 months there had been no recurrence of gastrointestinal bleeding. The case suggests that mechanical valve replacement may not prevent gastrointestinal bleeding in Heyde syndrome and that octreotide treatment should be considered in these cases.

  8. Double-arterial cannulation for aortic valve replacement with porcelain aorta.

    PubMed

    De Paulis, Ruggero; Maselli, Daniele; Scaffa, Raffaele; Nardella, Saverio

    2009-10-01

    We describe a new technique of aortic valve replacement (AVR) in patients with porcelain aorta. Three patients (mean age 75 years) were treated. The cardiopulmonary bypass (CPB) was established after side-graft right axillary artery and direct femoral artery cannulation. Venous drainage was obtained by atrio-caval cannulation. The procedures were performed in mild hypothermia (30 degrees C). Cerebral perfusion was carried out by clamping the innominate artery and all epiaortic vessels. The aorta was endoclamped by a Foley balloon inserted into the isthmus. The aorta was then opened longitudinally for 10 cm to expose and replace the aortic valve. Near-infra-red spectroscopy (NIRS) and bilateral radial artery pressure were used to monitor effective cerebral perfusion. Operative mortality was absent. The mean time of CPB was 73 min. NIRS-derived tissue oxygenation was maintained above 55%. Postoperative course was uneventful. This technique has several advantages: first, the cannulation of right axillary and the common femoral artery allows simultaneous cerebral and systemic perfusion. Second, any form of cross-clamp is avoided and the aorta is occluded away from the epiaortic vessels. Third, there is an increased freedom to choose the best place for aortotomy.

  9. Novel valve replacement with an extracellular matrix scaffold in an infant with single ventricle physiology.

    PubMed

    Guariento, Alvise; Burke, Redmond; Fedrigo, Marny; Angelini, Annalisa; Maschietto, Nicola; Vida, Vladimiro; Thiene, Gaetano; Stellin, Giovanni; Padalino, Massimo

    2016-01-01

    Valve replacement in children with functionally univentricular hearts remains challenging. The absence of small prostheses, the lack of growth, and the need for anticoagulation limit these procedures. We describe a 1-year follow-up of an extracellular matrix scaffold tube used as systemic atrio-ventricular valve in an infant. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Injuries to the Aorta, Aortic Annulus, and Left Ventricle During Transcatheter Aortic Valve Replacement: Management and Outcomes.

    PubMed

    Langer, Nathaniel B; Hamid, Nadira B; Nazif, Tamim M; Khalique, Omar K; Vahl, Torsten P; White, Jonathon; Terre, Juan; Hastings, Ramin; Leung, Diana; Hahn, Rebecca T; Leon, Martin; Kodali, Susheel; George, Isaac

    2017-01-01

    The experience with transcatheter aortic valve replacement is increasing worldwide; however, the incidence of potentially catastrophic cardiac or aortic complications has not decreased. In most cases, significant injuries to the aorta, aortic valve annulus, and left ventricle require open surgical repair. However, the transcatheter aortic valve replacement patient presents a unique challenge as many patients are at high or prohibitive surgical risk and, therefore, an open surgical procedure may not be feasible or appropriate. Consequently, prevention of these potentially catastrophic injuries is vital, and practitioners need to understand when open surgical repair is required and when alternative management strategies can be used. The goal of this article is to provide an overview of current management and prevention strategies for major complications involving the aorta, aortic valve annulus, and left ventricle. © 2016 American Heart Association, Inc.

  11. Multicenter Analysis of Clinical Follow-Ups in Patients with a Star GK Cardiac Valve Replacement for More than One Year.

    PubMed

    Li, Mingwen; Xiao, Yingbin; Chen, Daozhong; Liu, Liming; Ma, Liming; Wang, Pingfan; Jia, Kui; Yang, Kai; Chen, Lin

    2016-05-18

    Star GK valves were widely used in China, and we studied the clinical follow-up results of patients with Star GK valve implants for more than one year.  Clinical data were collected from those patients who had Star GK valve implants for over one year. Patients were divided into three groups: (1) AVR group: received aortic valve replacement surgery. Based on the valve model this group was further sub-divided into two groups: 21A group, and 23A group; (2) MVR group: received mitral valve replacement surgery. Based on the valve model this group was further sub-divided into three groups: 25M group, 27M group, and 29M group; (3) DVR group: received combined replacement surgeries including AVR + MVR. According to postoperative follow-up time these patients were divided into two groups: 1-year group and 3-year group. Follow-up data were collected by telephone, outpatient visits, or correspondence. Clinical data were aggregated by professional data scientists to conduct independent analyses.  959 patients were included in the study following Star GK valve implant. Follow-up after 1 year found that thrombosis occurred in 4 cases, hemorrhage in 15 cases, left heart failure in 13 cases, paravalvular leakage in 5 cases, and death due to cardiac causes in 2 cases.  The long-term efficacy of Star GK valve implants was satisfactory with low incidence of valve-related complications, and following Star GK valve implant, valve and blood were highly compatible and blood component damage was minor. Very low incidence rate of thrombosis was observed following Star GK valve implant, however, attention should be paid to adjust the anticoagulation intensity.

  12. [Experience of Mitral Valve Replacement Using a Pulmonary Autograft (Ross II Operation) in an Infant;Report of a Case].

    PubMed

    Kawahito, Tomohisa; Egawa, Yoshiyasu; Yoshida, Homare; Shimoe, Yasushi; Onishi, Tatsuya; Miyagi, Yuhichi; Terada, Kazuya; Ohta, Akira

    2015-07-01

    A 24-day-old boy suddenly developed progressive heart failure and was transported to our hospital. Echocardiography showed massive mitral regurgitation due to chordal rupture. Mitral valve repair was performed at 28 days of life, but postoperative valvular function was not satisfactory. A mechanical valve was implanted in the supra-annular position at 37 days of life. Two months after valve replacement, the mechanical valve was suddenly stuck. Emergent redo valve replacement was performed, but the prosthetic valve became stuck again 2 months after the 3rd operation, despite sufficient anti-coagulation therapy. At the 4th operation (6 months after birth), we implanted a pulmonary autograft in the mitral position instead of another mechanical valve in an emergent operation. The right ventricular outflow tract was reconstructed with a valved conduit. A postoperative catheter examination, which was performed 1 year after the Ross II operation, showed mild mitral stenosis with no regurgitation. Previous reports of Ross II operations in infants are rare and long-term results are unknown. However, we advocate that this procedure should be a rescue operation for mitral valve dysfunction in the early period of infants.

  13. Multi-physics 3D computational study of leaflet thrombus formation following surgical and transcatheter aortic valve replacement

    NASA Astrophysics Data System (ADS)

    Vahidkhah, Koohyar; Abbasi, Mostafa; Barakat, Mohammed; Dvir, Danny; Azadani, Ali

    2017-11-01

    An increasingly recognized complication following surgical/transcatheter aortic valve replacement is thrombosis or blood clot formation on replacement valve leaflets. A predisposing factor in thrombus formation on biomaterial surfaces of a bioprosthetic heart valve is blood stasis. Longer residence time of blood provides an opportunity for platelets and agonists to accumulate to critical concentrations that leads to platelet activation and then thrombosis. In this study, we have developed a fluid-solid interaction (FSI) modeling approach, to quantify blood stasis on the leaflets of bioprosthetic aortic valves with different design operating in a patient-specific geometry. We have validated our FSI model against experimental measurements of valve opening/closing as well as in-vitro particle image velocimetry. We have also embedded in our method a model for transport of platelets and agonists (ADP, TxA2, and thrombin) and their interactions that result in platelets activation and adhesion to biomaterial bioprosthetic surfaces. We have provided quantitative evidence for the correlation between long residence of blood on bioprosthetic aortic valve leaflets and formation of high thrombogenicity risk regions on the leaflets that are characterized by accumulation of activated platelet.

  14. Impact of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mechanical mitral valve replacement for rheumatic mitral valve disease.

    PubMed

    Wang, Bin; Xu, Zhi-yun; Han, Lin; Zhang, Guan-xin; Lu, Fang-lin; Song, Zhi-gang

    2013-03-01

    The prognostic significance of preoperative atrial fibrillation on mitral valve replacement remains unclear. The aim of this study was to explore the effects of the presence of preoperative atrial fibrillation on mortality and cardiovascular outcomes of mitral valve replacement for rheumatic valve disease. A retrospective analysis was performed on a total of 793 patients who underwent mitral valve replacement with or without tricuspid valve repair in our hospital. The patients selected were divided into two groups according to preoperative rhythm status. Patients with preoperative atrial fibrillation were assigned to the AF group, while patients in preoperative sinus rhythm were assigned to the SR group. Postoperative follow-up was performed by outpatient visits, as well as by telephone and written correspondence. Data gathered included survivorship, postoperative complications, left ventricular function and tricuspid regurgitation. For patients with atrial fibrillation vs those in sinus rhythm, there was no difference in postoperative mortality and morbidity. Follow-up was a mean of 8.6 ± 2.4 years. For patients with preoperative atrial fibrillation, 10-year survival from a Kaplan-Meier curve was 88.7%, compared with 96.6% in patients with preoperative sinus rhythm (P = 0.002). Multivariate analysis identified low left ventricular ejection fraction, older age, large left atrium and preoperative atrial fibrillation as significant adverse predictors for overall survival. Freedom from thromboembolism complications at 13 years was lower for patients with preoperative atrial fibrillation without maze procedure and left atrial appendage ligation, compared with that for patients with preoperative sinus rhythm without maze procedure and left atrial appendage ligation, and patients with concomitant maze procedure and left atrial appendage ligation (76.3 vs 94.8 vs 94.0%, respectively; P = 0.001). On echocardiography, the proportion of patients with significant tricuspid

  15. Conscious Sedation Versus General Anesthesia in Transcatheter Aortic Valve Replacement: The German Aortic Valve Registry.

    PubMed

    Husser, Oliver; Fujita, Buntaro; Hengstenberg, Christian; Frerker, Christian; Beckmann, Andreas; Möllmann, Helge; Walther, Thomas; Bekeredjian, Raffi; Böhm, Michael; Pellegrini, Costanza; Bleiziffer, Sabine; Lange, Rüdiger; Mohr, Friedrich; Hamm, Christian W; Bauer, Timm; Ensminger, Stephan

    2018-03-26

    The aims of this study were to report on the use of local anesthesia or conscious sedation (LACS) and general anesthesia in transcatheter aortic valve replacement and to analyze the impact on outcome. Transcatheter aortic valve replacement can be performed in LACS or general anesthesia. Potential benefits of LACS, such as faster procedures and shorter hospital stays, need to be balanced with safety. A total of 16,543 patients from the German Aortic Valve Registry from 2011 to 2014 were analyzed, and propensity-matched analyses were performed to correct for potential selection bias. LACS was used in 49% of patients (8,121 of 16,543). In hospital, LACS was associated with lower rates of low-output syndrome, respiratory failure, delirium, cardiopulmonary resuscitation, and death. There was no difference in paravalvular leakage (II+) between LACS and general anesthesia in the entire population (5% vs. 4.8%; p = 0.76) or in the matched population (3.9% vs. 4.9%, p = 0.13). The risk for prolonged intensive care unit stay (≥3 days) was significantly reduced with LACS (odds ratio: 0.82; 95% confidence interval [CI]: 0.73 to 0.92; p = 0.001). Thirty-day mortality was lower with LACS in the entire population (3.5% vs. 4.9%; hazard ratio [HR]: 0.72; 95% CI: 0.60 to 0.86; p < 0.001) and in the matched population (2.8% vs. 4.6%; HR: 0.6; 95% CI: 0.45 to 0.8; p < 0.001). However, no differences in 1-year mortality between both groups in the entire population (16.5% vs. 16.9%; HR: 0.93; 95% CI: 0.85 to 1.02; p = 0.140) and in the propensity-matched population (14.1% vs. 15.5%; HR: 0.90; 95% CI: 0.78 to 1.03; p = 0.130) were observed. Use of LACS in transcatheter aortic valve replacement is safe, with fewer post-procedural complications and lower early mortality, suggesting its broad application. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Long-term results of aortic valve replacement with Edwards Prima Plus stentless bioprosthesis: eleven years' follow up.

    PubMed

    Auriemma, Stefano; D'Onofrio, Augusto; Brunelli, Massimo; Magagna, Paolo; Paccanaro, Mariemma; Rulfo, Fanny; Fabbri, Alessandro

    2006-09-01

    The Edwards Lifesciences Prima Plus stentless valve (ELSV) is a bioprosthesis manufactured from a porcine aortic root. The study aim was to evaluate late clinical outcomes after aortic valve replacement (AVR) with ELSV implanted as a miniroot in patients with aortic valve disease. Between 1993 and 2004, 318 patients (232 males, 86 females; mean age 69 +/- 9 years; range: 37-83 years) underwent AVR with the ELSV. Preoperatively, 102 patients (32%), 162 (51%) and 54 (17%) were in NYHA classes I/II, III and IV, respectively. Aortic stenosis, aortic regurgitation and combined lesions were present in 124 patients (39%), 114 (36%) and 41 (13%), respectively. Twenty patients (6%) were referred for an acute aortic dissection, 20 (6%) for an aortic root aneurysm, and 139 (44%) had an associated aneurysmal dilatation of the ascending aorta. The ascending aorta was replaced in 159 patients (50%); aortic arch replacement was required in 10 (3%). Coronary artery bypass graft was performed in 86 patients (27%). The follow up was based on clinical data. Operative mortality was 5% (n = 17). There were 49 late deaths (5.2%/pt-yr). Valve-related mortality occurred in 10 patients (1%/pt-yr). Actuarial survival at five and 10 years was 78% and 33%, respectively. Actuarial freedom from valve reoperation and structural valve deterioration at 10 years were 100% and 64%. Actuarial freedom from embolic events and endocarditis at 10 years were 84% and 81%, respectively. The ELSV, when implanted as a miniroot, provided good early and long-term results in terms of survival and freedom from major complications.

  17. The receptor tyrosine kinase Pvr promotes tissue closure by coordinating corpse removal and epidermal zippering

    PubMed Central

    Garlena, Rebecca A.; Lennox, Ashley L.; Baker, Lewis R.; Parsons, Trish E.; Weinberg, Seth M.; Stronach, Beth E.

    2015-01-01

    A leading cause of human birth defects is the incomplete fusion of tissues, often manifested in the palate, heart or neural tube. To investigate the molecular control of tissue fusion, embryonic dorsal closure and pupal thorax closure in Drosophila are useful experimental models. We find that Pvr mutants have defects in dorsal midline closure with incomplete amnioserosa internalization and epidermal zippering, as well as cardia bifida. These defects are relatively mild in comparison to those seen with other signaling mutants, such as in the JNK pathway, and we demonstrate that JNK signaling is not perturbed by altering Pvr receptor tyrosine kinase activity. Rather, modulation of Pvr levels in the ectoderm has an impact on PIP3 membrane accumulation, consistent with a link to PI3K signal transduction. Polarized PI3K activity influences protrusive activity from the epidermal leading edge and the protrusion area changes in accord with Pvr signaling intensity, providing a possible mechanism to explain Pvr mutant phenotypes. Tissue-specific rescue experiments indicate a partial requirement in epithelial tissue, but confirm the essential role of Pvr in hemocytes for embryonic survival. Taken together, we argue that inefficient removal of the internalizing amnioserosa tissue by mutant hemocytes coupled with impaired midline zippering of mutant epithelium creates a situation in some embryos whereby dorsal midline closure is incomplete. Based on these observations, we suggest that efferocytosis (corpse clearance) could contribute to proper tissue closure and thus might underlie some congenital birth defects. PMID:26293306

  18. Percutaneous Closure of 2 Paravalvular Leaks and a Gerbode Defect after Mitral Valve Replacement for Infective Endocarditis.

    PubMed

    Peñalver, Jorge; Shatila, Wassim; Silva, Guilherme V

    2017-04-01

    Surgical valve replacement after infective endocarditis can result in local destructive paravalvular lesions. A 30-year-old woman with infective endocarditis underwent mitral valve replacement that was complicated postoperatively by 2 paravalvular leaks. During percutaneous closure of the leaks, a Gerbode defect was also found and closed. We discuss our patient's case and its relation to others in the relevant medical literature. To our knowledge, we are the first to describe the use of a percutaneous approach to close concomitant paravalvular leaks and a Gerbode defect.

  19. Implementation of transcatheter aortic valve replacement in California: Influence on aortic valve surgery.

    PubMed

    Maximus, Steven; Milliken, Jeffrey C; Danielsen, Beate; Shemin, Richard; Khan, Junaid; Carey, Joseph S

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) procedures were introduced in 2011. Initially, procedures were limited to patients who were not surgical candidates, but subsequently high-risk surgical candidates were considered for TAVR. The influence on aortic valve surgery in California is unknown. The California Office of Statewide Health Planning and Development hospitalized patient discharge database was queried for the years 2009 through 2014. isolated surgical aortic valve and aortic valve/coronary artery bypass graft (SAVR) and TAVR procedures were identified by International Classification of Diseases-9th revision clinical modification procedure codes. Seven TAVR programs were introduced in 2011, 12 in 2012, 3 in 2013, and 6 in 2014. SAVR procedure volumes were compared from the 2 years before institution with SAVR volumes during the year(s) after institution of the TAVR program in these 28 hospitals. Overall, surgical volumes increased during the first, second, and third years after implementation of TAVR procedures. Among 7 hospitals with 4-year programs, surgical volumes increased to a maximum of 15.5% during the third year, then began to decrease. The hospital performing the largest number of TAVR procedures showed a marked decrease in SAVR volume by the fourth year, suggesting a shift of SAVR candidates to TAVR. Among all hospitals with 4-year programs, TAVR exceeded SAVR procedures by the fourth year. In California overall, SAVR increased during 2011 through 2013, due primarily to increasing volume of isolated SAVR procedures. Statewide, isolated SAVR increased from a yearly average of 3111 procedures during 2009-2010 to 3592 (+15.5%) in 2013, then decreased slightly in 2014. SAVR plus coronary artery bypass graft procedures decreased during the same time period. After implementation of TAVR, hospital SAVR volumes increased moderately, then began to decrease by the fourth year, when TAVR volume exceeded SAVR. Surgical candidates may be identified

  20. Coronary artery compression by teflon pledget granuloma following aortic valve replacement.

    PubMed

    Cohle, S D; Delavan, J W

    1997-09-01

    We describe a massive fatal posterior myocardial infarct resulting from compression of the right coronary artery by a Teflon pledget granuloma in a patient who had undergone aortic valve replacement six months before death. Other iatrogenic causes of coronary artery occlusion or compression are discussed in this paper. To our knowledge this is the first report of this surgical complication.

  1. Minimally invasive aortic valve replacement – pros and cons of keyhole aortic surgery

    PubMed Central

    Szałański, Przemysław; Zembala, Michał; Filipiak, Krzysztof; Karolak, Wojciech; Wojarski, Jacek; Garbacz, Marcin; Kaczmarczyk, Aleksandra; Kwiecień, Anna; Zembala, Marian

    2015-01-01

    Over the last twenty years, minimally invasive aortic valve replacement (MIAVR) has evolved into a safe, well-tolerated and efficient surgical treatment option for aortic valve disease. It has been shown to reduce postoperative morbidity, providing faster recovery and rehabilitation, shorter hospital stay and better cosmetic results compared with conventional surgery. A variety of minimally invasive accesses have been developed and utilized to date. This concise review demonstrates and discusses surgical techniques used in contemporary approaches to MIAVR and presents the most important results of MIAVR procedures. PMID:26336491

  2. Integrating bio-prosthetic valves in the Fontan operation - Novel treatment to control retrograde flow in caval veins

    NASA Astrophysics Data System (ADS)

    Vukicevic, Marija; Conover, Timothy; Zhou, Jian; Hsia, Tain-Yen; Figliola, Richard

    2012-11-01

    For a child born with only one functional heart ventricle, the sequence of palliative surgeries typically culminates in the Fontan operation. This procedure is usually successful initially, but leads to later complications, for reasons not fully understood. Examples are respiratory-dependent retrograde flows in the caval and hepatic veins, and increased pulmonary vascular resistance (PVR), hypothesized to be responsible for elevated pressure in the liver and disease of the liver and intestines. Here we study the parameters responsible for retrograde flows in the inferior vena cava (IVC) and hepatic vein (HV), and investigate two novel interventions to control retrograde flow: implanting either a Medtronic Contegra valved conduit or an Edwards lifescience pericardial aortic valve in the IVC or HV. We performed the experiments in a multi-scale, patient specific mock circuit, with normal and elevated PVR, towards the optimization of the Fontan circulation. The results show that both valves can significantly reduce retrograde flows in the veins, suggesting potential advantages in the treatment of the patients with congenital heart diseases. Fondation Leducq

  3. Regional Systems of Care to Optimize Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement.

    PubMed

    Stub, Dion; Lauck, Sandra; Lee, May; Gao, Min; Humphries, Karin; Chan, Albert; Cheung, Anson; Cook, Richard; Della Siega, Anthony; Leipsic, Jonathon; Charania, Jay; Dvir, Danny; Latham, Tim; Polderman, Jopie; Robinson, Simon; Wong, Daniel; Thompson, Christopher R; Wood, David; Ye, Jian; Webb, John

    2015-12-28

    This study sought to describe the development of a multicenter, transcatheter aortic valve replacement program and regional systems of care intended to optimize coordinated, efficient, and appropriate delivery of this new therapy. Transcatheter aortic valve replacement (TAVR) has become an accepted treatment option for patients with severe aortic stenosis who are at high surgical risk. Regional systems of care have led to improvements in outcomes for patients undergoing intervention for myocardial infarction, cardiac arrest, and stroke. We implemented a regional system of care for patients undergoing TAVR in British Columbia, Canada. We describe a prospective observational cohort of 583 patients who underwent TAVR in British Columbia between 2012 and 2014. Regionalization of TAVR care in British Columbia refers to a centrally coordinated, funded, and evaluated program led by a medical director and a multidisciplinary advisory group that oversees planning, access to care, and quality of outcomes at the 4 provincial sites. Risk-stratified case selection for transfemoral TAVR is performed by heart teams at each site on the basis of consensus provincial indications. Referrals for lower volume and more complicated TAVR, including nontransfemoral access and valve-in-valve procedures, are concentrated at a single site. In-hospital and 30-day outcomes are reported. The median age was 83 years (interquartile range [IQR]: 78 to 87 years) and median STS score was 6% (IQR: 4% to 8%). Transfemoral access was performed in 499 (85.6%) cases and nontransfemoral in 84 (14.4%). Transcatheter valve-in-valve procedures in for failed bioprosthetic valves were performed in 43 patients (7.4%). A balloon-expandable valve was inserted in 386 (66.2%) and a self-expanding valve in 189 (32.4%). All-cause 30-day mortality was 3.5%. All-cause in-hospital mortality and disabling stroke occurred in 3.1% and 1.9%, respectively. Median length of stay was 3 days (IQR: 3 to 6 days), with 92.8% of

  4. [Electroacupuncture intervention combined with general anesthesia for 80 cases of heart valve replacement surgery under cardiopulmonary bypass].

    PubMed

    Chi, Hao; Zhou, Wen-Xiong; Wu, Yao-Yao; Chen, Tong-Yu; Ge, Wen; Yuan, Lan; Shen, Wei-Dong; Zhou, Jia

    2014-02-01

    To determine whether electroacupuncture (EA) intervention combined with general anesthesia (GA) strategy can reduce early post-operative morbidity and medical costs in patients undergoing heart valve replacement operation under cardiopulmonary bypass. A total of 160 heart valve replacement surgery patients undergoing cardiopulmonary bypass were randomly divided into GA and EA + GA groups (n = 80 in each group). Patients of the GA group were given with intravenous injection of Fentanyl, Midazolam, Vecuronium Bromide, etc. and routine tracheal intubation. EA (3-4 Hz, 2.0-2.2 mA) was applied to bilateral Zhongfu (LU 1), Chize (LU 5) and Ximen (PC 4) beginning about 20 mm before the surgery in the EA + GA group. Endotracheal intubation was not employed but only prepared as a standby for patients of the EA + GA group. The dosage of narcotic drugs, duration of surgery, duration of aertic blockage, rate of cardiac re-beating, volumes of post-operative blood transfusion, discharge volume, cases of post-operative pulmonary infection, vocal cord injury, and the time of first bed-off, first eating and duration in intensive care unit (IOU) residence. etc. were recorded. The successful rates of heart valve replacement surgery were similar in both GA and EA + GA groups. Compared with the GA group, the dosages of Fentanyl, Midazolam and Vecuronium of the EA + GA group were significantly lower (P < 0.05, P < 0.01), the numbers of patients needing blood-transfusion, antibiotics treatment, and suffering from pulmonary infection were fewer, the time of first bed-off and duration of hospitalizetion and IOU residence were considerably shorter (P < 0.05, P < 0.01) and the total medical cost was obviously lower (P < 0.05) in the EA + GA group. EA combined with general anesthesia strategy for heart valve replacement surgery without endotracheal intubation is safe and can reduce post-operative morbidity and medical costs in patients undergoing heart valve replacement surgery under

  5. Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience

    PubMed Central

    2011-01-01

    Objectives To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. Methods Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. Results Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). Conclusions The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade. PMID:21699696

  6. Contemporary Costs Associated With Transcatheter Aortic Valve Replacement: A Propensity-Matched Cost Analysis.

    PubMed

    Ailawadi, Gorav; LaPar, Damien J; Speir, Alan M; Ghanta, Ravi K; Yarboro, Leora T; Crosby, Ivan K; Lim, D Scott; Quader, Mohammed A; Rich, Jeffrey B

    2016-01-01

    The Placement of Aortic Transcatheter Valve (PARTNER) trial suggested an economic advantage for transcatheter aortic valve replacement (TAVR) for high-risk patients. The purpose of this study was to evaluate the cost effectiveness of TAVR in the "real world" by comparing TAVR with surgical aortic valve replacement (SAVR) in intermediate-risk and high-risk patients. A multiinstitutional database of The Society of Thoracic Surgeons (STS) (2011 to 2013) linked with estimated cost data was evaluated for isolated TAVR and SAVR operations (n = 5,578). TAVR-treated patients (n = 340) were 1:1 propensity matched with SAVR-treated patients (n = 340). Patients undergoing SAVR were further stratified into intermediate-risk (SAVR-IR: predicted risk of mortality [PROM] 4% to 8%) and high-risk (SAVR-HR: PROM >8%) cohorts. Median STS PROM for TAVR was 6.32% compared with 6.30% for SAVR (SAVR-IR 4.6% and SAVR-HR 12.4%). A transfemoral TAVR approach was most common (61%). Mortality was higher for TAVR (10%) compared with SAVR (6%, p < 0.047), whereas the SAVR group accrued higher major morbidity (27% vs 14%, p < 0.001) and longer postoperative hospital duration (7 days vs 6 days, p < 0.001). Importantly, TAVR incurred twice the median total costs compared with SAVR ($69,921 vs $33,598, p < 0.001). The increased cost of TAVR was largely driven by the cost of the valve (all p < 0.001). Intermediate-risk patients undergoing SAVR demonstrated the most exaggerated cost savings versus TAVR. TAVR was associated with greater total costs and mortality compared with SAVR in intermediate-risk and high-risk patients while conferring lower major morbidity and improved resource use. Increased cost of TAVR appears largely related to the cost of the valve. Until the price of TAVR valves decreases, these data suggest that TAVR may not provide the most cost-effective strategy, particularly for intermediate-risk patients. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc

  7. Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

    PubMed

    Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe

    2017-07-01

    After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.

  8. Impact of Annular Size on Outcomes After Surgical or Transcatheter Aortic Valve Replacement.

    PubMed

    Deeb, G Michael; Chetcuti, Stanley J; Yakubov, Steven J; Patel, Himanshu J; Grossman, P Michael; Kleiman, Neal S; Heiser, John; Merhi, William; Zorn, George L; Tadros, Peter N; Petrossian, George; Robinson, Newell; Mumtaz, Mubashir; Gleason, Thomas G; Huang, Jian; Conte, John V; Popma, Jeffrey J; Reardon, Michael J

    2018-04-01

    This analysis evaluates the relationship of annular size to hemodynamics and the incidence of prosthesis-patient mismatch (PPM) in surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) patients. The CoreValve US Pivotal High Risk Trial, described previously, compared TAVR using a self-expanding valve with SAVR. Multislice computed tomography was used to categorize TAVR and SAVR subjects according to annular perimeter-derived diameter: large (≥26 mm), medium (23 to <26 mm), and small (<23 mm). Hemodynamics, PPM, and clinical outcomes were assessed. At all postprocedure visits, mean gradients were significantly lower for TAVR compared with SAVR in small and medium size annuli (p < 0.001). Annular size was significantly associated with mean gradient after SAVR, with small annuli having the highest gradients (p < 0.05 at all timepoints); gradients were similar across all annular sizes after TAVR. In subjects receiving SAVR, the frequency of PPM was significantly associated with annular size, with small annuli having the greatest incidence. No difference in PPM incidence by annular sizing was observed with TAVR. In addition, TAVR subjects had significantly less PPM than SAVR subjects in small and medium annuli (p < 0.001), with no difference in the incidence of PPM between TAVR and SAVR in large annuli (p = 0.10). Annular size has a significant effect on hemodynamics and the incidence of PPM in SAVR subjects, not observed in TAVR subjects. With respect to annular size, TAVR results in better hemodynamics and less PPM for annuli less than 26 mm and should be strongly considered when choosing a tissue valve for small and medium size annuli. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Clinical Outcomes Following Transcatheter Aortic Valve Replacement in Asian Population.

    PubMed

    Yoon, Sung-Han; Ahn, Jung-Min; Hayashida, Kentaro; Watanabe, Yusuke; Shirai, Shinichi; Kao, Hsien-Li; Yin, Wei-Hsian; Lee, Michael Kang-Yin; Tay, Edgar; Araki, Motoharu; Yamanaka, Futoshi; Arai, Takahide; Lin, Mao-Shin; Park, Jun-Bean; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Muramatsu, Toshiya; Hanyu, Michiya; Kozuma, Ken; Kim, Hyo-Soo; Saito, Shigeru; Park, Seung-Jung

    2016-05-09

    This study describes the characteristics of a real-world Asian patient population treated with transcatheter aortic valve replacement (TAVR) and evaluates their clinical outcomes. No previously reported randomized or observational studies adequately assess the safety and efficacy of TAVR in an Asian population. The Asian TAVR registry is an international multicenter study that enrolled patients with aortic stenosis who underwent TAVR in Asian countries. In total, 848 patients with mean STS score of 5.2 ± 3.8% were enrolled between March 2010 and September 2014 at 11 centers in 5 countries. The Edwards Sapien or Medtronic CoreValve was implanted in 64.7% and 35.3% of patients, respectively. The procedural success rate was 97.5%. The 30-day and 1-year mortality rates were 2.5% and 10.8%, respectively. There was no difference in 1-year mortality between devices (Sapien: 9.4%; CoreValve: 12.2%; log-rank p = 0.40). The rates of stroke, life-threatening bleeding, major vascular complications and acute kidney injury (stage 2 to 3) were 3.8%, 6.4%, 5.0% and 3.3%, respectively. Moderate or severe paravalvular leakage was significantly more common with the CoreValve than Sapien (14.4% vs. 7.3%; p = 0.001). According to the multivariate model, a higher STS score, lower body mass index, New York Heart Association functional class III-IV symptoms, diabetes mellitus, prior cerebrovascular accident, low mean gradient at baseline, and moderate or severe paravalvular leakage were significantly associated with reduced survival. Despite anatomical features of concern, the clinical outcomes of TAVR in our Asian population were favorable in comparison with those of previously published trials and observational studies. (The Asian Transcatheter Aortic Valve Replacement Registry [Asian TAVR]; NCT02308150). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Bioprosthetic mitral valve replacement in patients aged 65 years or younger: long-term outcomes with the Carpentier-Edwards PERIMOUNT pericardial valve.

    PubMed

    Bourguignon, Thierry; Espitalier, Fabien; Pantaleon, Clémence; Vermes, Emmanuelle; El-Arid, Jean Marc; Loardi, Claudia; Karam, Elias; Candolfi, Pascal; Ivanes, Fabrice; Aupart, Michel

    2018-02-12

    Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. From 1984 to 2010, 148 Carpentier-Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. The mean follow-up period was 8.6 ± 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 ± 4%, 53 ± 6% and 31 ± 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 ± 5%, 47 ± 7% and 19 ± 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 ± 4%, 50 ± 6% and 25 ± 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 ± 5%. Expected valve durability was 14.2 years for this age group. In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Thrombocytopenia after aortic valve replacement with freedom solo bioprosthesis: a propensity study.

    PubMed

    Piccardo, Alessandro; Rusinaru, Dan; Petitprez, Benoit; Marticho, Paul; Vaida, Ioana; Tribouilloy, Christophe; Caus, Thierry

    2010-05-01

    The incidence of postoperative thrombocytopenia after aortic valve replacement with the Freedom Solo bioprosthesis remains unclear. This propensity-matched study was carried out to evaluate the incidence and clinical impact of thrombocytopenia in patients receiving the Freedom Solo bioprosthesis. Patients who underwent aortic valve replacement with a Freedom Solo or Carpentier-Edwards Perimount pericardial prosthesis at our institution between 2006 and 2008 were screened retrospectively. Exclusion criteria included double valve replacement, redo surgery, and active endocarditis. Two hundred six patients were considered eligible for this analysis. Using propensity scores 36 matched pairs of patients with a Freedom Solo or Perimount bioprosthesis were obtained. The primary end point was the occurrence of postoperative thrombocytopenia. Secondary end points were postoperative thromboembolic or hemorrhagic events and 30-day mortality. Before matching, severe thrombocytopenia (<30 x 10(9) platelets/L) occurred in 22% of patients with a Freedom Solo bioprosthesis and 1% with a Perimount bioprosthesis (p < 0.0001), thromboembolic or hemorrhagic events occurred in 3% and 2%, respectively (p = 0.37), and 30-day mortality was 4% and 6%, respectively (p = 0.48). Multivariate analysis identified preoperative platelet count (p = 0.01) and Freedom Solo (p < 0.0001) as independent risk factors for severe postoperative thrombocytopenia. After matching, severe thrombocytopenia occurred in 25% and 3% of patients with Freedom Solo and Perimount bioprostheses, respectively (p < 0.0001), thromboembolic or hemorrhagic events occurred in 0%, and 30-day mortality was 3% and 6%, respectively (p = 0.99). The risk of thrombocytopenia was high after Freedom Solo implantation. However, this complication was not related to any deleterious events in our study population. Copyright (c) 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Immediate Outcomes of Aortic Valve Replacement with Sutureless versus Stentless Bioprosthesis.

    PubMed

    Ihsan Parlar, Ali; Onur Hanedan, Muhammet; Mataraci, Ilker; Ali Yuruk, Mehmet; Sayar, Ufuk; Kemal Arslan, Ali; Ozer, Tanil

    2016-01-01

    Aortic valve replacement (AVR) with a sutureless valve is an innovative therapy in high-risk elderly patients. The study aim was to compare the early results of AVR using sutureless aortic valves or stentless aortic bioprostheses. A retrospective analysis was conducted of 55 patients who underwent AVR with either a sutureless valve (Perceval S; n = 24 or Edwards Intuity; n = 9) or a stentless valve (Sorin Freedom SOLO™; n = 22). Baseline patient characteristics were similar in both groups, except for NYHA class. Concomitant procedures were performed in 17 patients (51.5%) of the sutureless group and in nine patients (40.9%) of the stentless group (p = 0.44). The aortic cross-clamp time was 55 ± 23 min in the sutureless group and 102 ± 36 min in the stentless group (p <0.0001), while the postoperative peak aortic gradient was 19.5 ± 5.0 mmHg and 29.3 ± 15.4 mmHg for the sutureless group and stentless group, respectively (p = 0.037). The postoperative mean gradient was 9.3 ± 3.4 mmHg for the sutureless group and 15.1 ± 10.5 mmHg for the stentless group (p = 0.06). Blood product transfusion was required less frequently by the sutureless group, but drainage and bleeding was similar in both groups. The intensive care unit and hospital stays were significantly shorter in favor of the sutureless group. One sutureless patient (3.0%) and two stentless patients (9.1%) died in hospital (p = 0.557). Early results of the present study suggested that surgical AVR with a sutureless valve is associated with a good hemodynamic performance and an improved early outcome.

  13. Quality of life following heart valve replacement in the elderly.

    PubMed

    Spaziano, Marco; Carrier, Michel; Pellerin, Michel; Choinière, Manon

    2010-07-01

    The purpose of this investigation was to evaluate both long-term functional status and quality of life (QoL) following valvular replacement surgery in octogenarians. The influence of gender and discharge location was also examined. A total of 133 patients (age range: 80-89 years) who underwent surgical valve replacement between January 2003 and December 2006 was identified. Two questionnaires evaluating QoL (SF-12v2 and MLHFQ), as well as a demographic questionnaire, were sent to these patients. The response rate was 64.4%. Among the participants, the mean NYHA functional class improved from 2.7 to 1.4 after surgery. Men showed results similar to those of the age-matched general Canadian population on the mental and physical component scales of the SF-12v2. The data on women were similar to those of the general population on the physical component scale, but their scores were significantly lower on the mental component scale of the SF-12v2. Further analysis of the results comparing discharge location for each gender revealed that women discharged to a convalescence resource had significantly better QoL scores than those discharged to home with regards to the physical component scale of the SF-12v2, the total score of the MLHFQ, and the physical dimension score of the MLHFQ. Patients aged > or = 80 years benefit from heart valve replacement surgery in terms of both QoL and functional status. Women may be at increased risk of a decline in their emotional well-being and, postoperatively, may benefit more from convalescence than from discharge to home.

  14. Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results.

    PubMed

    Vrandecic, M; Gontijo Filho, B; Fantini, F; Barbosa, J; Martins, I; de Oliveira, O C; Martins, C; Max, R; Drumond, L; Oliveira, C; Ferrufino, A; Alcocer, E; Silva, J A; Vrandecic, E

    1998-03-01

    The study aimed to determine the clinical performance of bovine pericardial aldehyde-treated products alone or in combination with aortic leaflets of porcine origin. These included a composite porcine stentless aortic valve attached to a scalloped pericardial tube (BSAV), and valved and non-valved bovine pericardial conduits for use in left-sided heart lesions (BPG). For BSAV grafts, between January 1990 and August 1996, 163 patients (119 males) had their aortic valves replaced by SJM Biocor BASV. Mean age was 37.9 +/- 17.6 years (range: 1 to 76 years). Rheumatic heart disease sequelae (n = 72) and replacement of a prosthetic heart valve (n = 46) were predominant. Preoperative NYHA functional class showed 90 patients (55.2%) in class III and 50 (30.7%) in class IV. BPVC and NVPC grafts were used in 166 patients: acute aortic dissection was the main indication in 52 (31.3%) and chronic in 36 (21/7%). The ascending aorta was involved in 141 patients (84.9%); grafts were seldom used at other sites. In most patients the graft implanted was either a non-valved (n = 79) or a valved (n = 75) pericardial conduit. Twelve patients had a localized lesion and required a patch repair. For BASV grafts, the non-valve-related hospital mortality rate was 4.9%. There were 14.7% non-fatal complications with full recovery of all patients. Mean follow up in 141 patients was 3.0 +/- 1.4 years (range: 1 month to 7.2 years); 14 patients were lost to follow up. Late, non-conduit-related, mortality occurred in seven patients (4.9%). Eight patients underwent reoperation. The current clinical follow up of 127 patients has shown 118 (92.9%) with competent valves and nine (7.0%) with mild stable aortic insufficiency. For BPVC and NVPC grafts, hospital mortality rate was 16.9%, death being related to poor preoperative clinical condition. Postoperative follow up was accomplished in 125 patients; reoperation was necessary in seven patients. Histology showed good tissue preservation up to five

  15. Mycobacterium chimaera Infection After Aortic Valve Replacement Presenting With Aortic Dissection and Pseudoaneurysm.

    PubMed

    O'Neil, C R; Taylor, G; Smith, S; Joffe, A M; Antonation, K; Shafran, S; Kunimoto, D

    2018-02-01

    We present a case of Mycobacterium chimaera infection presenting with aortic dissection and pseudoaneuysm in a 22-year-old man with a past history of aortic valve replacement. Clinicians should consider M. chimaera infection in those presenting with aortic dissection as a late complication of cardiovascular surgery.

  16. Costs of transcatheter versus surgical aortic valve replacement in intermediate-risk patients.

    PubMed

    Osnabrugge, Ruben L J; Head, Stuart J; Genders, Tessa S S; Van Mieghem, Nicolas M; De Jaegere, Peter P T; van der Boon, Robert M A; Kerkvliet, J Marco; Kalesan, Bindu; Bogers, Ad J J C; Kappetein, A Pieter; Hunink, M G Myriam

    2012-12-01

    Transcatheter aortic valve replacement (TAVR) offers a new treatment option for patients with aortic stenosis, but costs may play a decisive role in decision making. Current studies are evaluating TAVR in an intermediate-risk population. We assessed the in-hospital and 1-year follow-up costs of patients undergoing TAVR and surgical aortic valve replacement (SAVR) at intermediate operative risk and identified important cost components. We prospectively collected clinical data on 141 patients undergoing TAVR and 405 undergoing SAVR. Propensity score matching yielded 42 matched pairs at intermediate risk. Costs were assessed using a detailed resource-use approach and compared using bootstrap methods. In-hospital costs were higher in TAVR patients than in SAVR patients (€40802 vs €33354, respectively; p=0.010). The total costs at 1 year were €46217 vs €35511, respectively (p=0.009). The TAVR was less costly with regard to blood products, operating room use, and length-of-stay. For intermediate-risk patients with severe aortic stenosis the costs at 1 year are higher for TAVR than for SAVR. The difference was mainly caused by the higher costs of the transcatheter valve and was not compensated by the lower costs for blood products and hospital stay in TAVR patients. Therefore, SAVR remains a clinically and economically attractive treatment option. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. The economic value of rapid deployment aortic valve replacement via full sternotomy.

    PubMed

    Moore, Matt; Barnhart, Glenn R; Chitwood, W Randolph; Rizzo, John A; Gunnarsson, Candace; Palli, Swetha R; Grossi, Eugene A

    2017-06-01

    To compare the economic value of EDWARDS INTUITY Elite™ (EIE) valve system for rapid-deployment aortic valve replacement (RDAVR) in a full sternotomy (FS) approach (EIE-FS-RDAVR) versus FS-AVR using conventional stented bioprosthesis. A simulation model to compare each treatment's 30-day inpatient utilization and complication rates utilized: clinical end points obtained from the TRANSFORM trial patient subset (EIE-FS-RDAVR) and a best evidence review of the published literature (FS-AVR); and costs from the Premier database and published literature. EIE-FS-RDAVR costs $800 less than FS-AVR per surgery episode attributable to lowered complication rates and utilization. Combined with the lower mortality, EIE-FS-RDAVR was a superior (dominant) technology versus FS-AVR. This preliminary investigation of EIE-FS-RDAVR versus conventional FS-AVR found the EIE valve offered superior economic value over a 30-day period. Real-world analyses with additional long-term follow-up are needed to evaluate if this result can be replicated over a longer timeframe.

  18. Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement

    PubMed Central

    Gunning, Paul S.; Saikrishnan, Neelakantan; Yoganathan, Ajit P.; McNamara, Laoise M.

    2015-01-01

    Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a ‘peel-back’ leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve. PMID:26674192

  19. In vitro investigation of a novel elastic vascular prosthesis for valve-sparing aortic root and ascending aorta replacement.

    PubMed

    Scharfschwerdt, Michael; Leonhard, Moritz; Lehmann, Judith; Richardt, Doreen; Goldmann, Helmut; Sievers, Hans-Hinrich

    2016-05-01

    Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular prosthesis providing elastic behaviours. In a first series (n = 14), haemodynamics and leaflet motions of the aortic valve were investigated and also cyclic changes of aortic dimensions at different levels of the root. In a second series (n = 7), intravascular pressure and dimensions of the proximal descending aorta were measured and the corresponding wall tension was calculated. Haemodynamics of the aortic valve remain comparable after replacement. Though the novel prosthesis does not feature such high distensibility as the native aorta, the dynamic of the root was significantly increased compared with common Dacron prostheses at the commissural level, preserving 'windkessel' function. Thus, wall tension of the residual aorta remained unchanged; nevertheless, maximum pressure-time differential dp/dt increased by 13%. The use of the novel elastic prosthesis for replacement of the ascending aorta seems to be beneficial, especially with regard to the preservation of the aortic windkessel. Further studies will be needed to clarify long-term utilization of the material in vivo. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Successful simultaneous ipsilateral stenting of common iliac artery stenosis and transfemoral aortic valve replacement.

    PubMed

    Aslan, Abdullah Nabi; Kasapkara, Hacı Ahmet; Sivri, Serkan; Güney, Murat Can; Bozkurt, Engin

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) was designed to treat elderly patients with severe aortic stenosis at high risk for surgery, and is most commonly performed with retrograde approach through femoral arteries. However, in up to 30% of cases, it is either not possible to use this access route or it is considered to have high risk of vascular injury. Alternative approaches have been described for patients with no suitable femoral access: trans-subclavian, transaortic, or direct aortic access; however, since the introduction of new valves deployed with low-profile delivery systems, another alternative transcatheter approach has been discovered. Presently described is experience in 2 cases in which patients were treated with transfemoral TAVR using Edwards SAPIEN 3 transcatheter heart valves immediately following ipsilateral common iliac artery stenting.

  1. An unusual cause of hemolysis in a patient with an aortic valved conduit replacement.

    PubMed

    Allman, Christine; Rajaratnam, Rohan; Kachwalla, Hashim; Hughes, Clifford F; Bannon, Paul; Leung, Dominic Y

    2003-02-01

    Hemolytic anemia is a well-known but uncommon complication in patients with prosthetic heart valves. It is most commonly a result of prosthetic valve dysfunction, periprosthetic valvular regurgitation, or both. We report a case of a 41-year-old man who had a previous aortic valve and root replacement for acute proximal aortic dissection, now presenting with hemolytic anemia. This was a result of flow obstruction at the distal anastomosis of the aortic conduit by the presence of multiple dissection flaps resulting in severe flow turbulence. Although the pathology was at the blind spot for transesophageal echocardiography, the dissection flaps, the flow turbulence, and the degree of obstruction were well-demonstrated by this technique after careful manipulation of the probe and a high index of suspicion.

  2. 1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial.

    PubMed

    Abdel-Wahab, Mohamed; Neumann, Franz-Josef; Mehilli, Julinda; Frerker, Christian; Richardt, Doreen; Landt, Martin; Jose, John; Toelg, Ralph; Kuck, Karl-Heinz; Massberg, Steffen; Robinson, Derek R; El-Mawardy, Mohamed; Richardt, Gert

    2015-08-18

    The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. The investigator-initiated trial randomized 241 high-risk patients with symptomatic severe aortic stenosis and anatomy suitable for treatment with both balloon- and self-expandable transcatheter heart valves to transfemoral transcatheter aortic valve replacement with either device. Patients were followed-up for 1 year, with assessment of clinical outcomes and echocardiographic evaluation of valve function. At 1 year, the rates of death of any cause (17.4% vs. 12.8%; relative risk [RR]: 1.35; 95% confidence interval [CI]: 0.73 to 2.50; p = 0.37) and of cardiovascular causes (12.4% vs. 9.4%; RR: 1.32; 95% CI: 0.63 to 2.75; p = 0.54) were not statistically significantly different in the balloon- and self-expandable groups, respectively. The frequencies of all strokes (9.1% vs. 3.4%; RR: 2.66; 95% CI: 0.87 to 8.12; p = 0.11) and repeat hospitalization for heart failure (7.4% vs. 12.8%; RR: 0.58; 95% CI: 0.26 to 1.27; p = 0.19) did not statistically significantly differ between the 2 groups. Elevated transvalvular gradients during follow-up were observed in 4 patients in the balloon-expandable group (3.4% vs. 0%; p = 0.12); all were resolved with anticoagulant therapy, suggesting a thrombotic etiology. More than mild paravalvular regurgitation was more frequent in the self-expandable group (1.1% vs. 12.1%; p = 0.005). Despite the higher device success rate with the balloon-expandable valve, 1-year follow-up of patients in CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT Trial), with limited statistical power, revealed clinical outcomes after transfemoral transcatheter aortic valve

  3. Intra-Operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves.

    PubMed

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper; Jensen, Maiken Brit; Lund, Jens Teglgaard; Pedersen, Mads Møller; Lange, Theis; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2016-10-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angle-independent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p < 0.0001), induced systolic backflow (p < 0.003) and reduced systolic jet width (p < 0.0001). After valve replacement, the systolic backflow and jet width were normalized (p < 0.52 and p < 0.22), but flow complexity was not (p < 0.0001). Flow complexity (p < 0.0001), systolic jet width (p < 0.0001) and systolic backflow (p < 0.001) were associated with peak systolic velocity. The study found that aortic stenosis changes blood flow in the ascending aorta and valve replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Preoperative Aspirin Use and Lung Injury After Aortic Valve Replacement Surgery: A Retrospective Cohort Study.

    PubMed

    Mazzeffi, Michael; Kassa, Woderyelesh; Gammie, James; Tanaka, Kenichi; Roman, Philip; Zhan, Min; Griffith, Bartley; Rock, Peter

    2015-08-01

    Acute respiratory distress syndrome (ARDS) occurs uncommonly after cardiac surgery but has a mortality rate as high as 80%. Aspirin may prevent lung injury in at-risk patients by reducing platelet-neutrophil aggregates in the lung. We hypothesized that preoperative aspirin use would be associated with a decreased risk of ARDS after aortic valve replacement surgery. We performed a retrospective single-center cohort study that included all adult patients who had aortic valve replacement surgery during a 5-year period. The primary outcome variable was postoperative ARDS. The secondary outcome variable was nadir PaO2/FIO2 ratio during the first 72 hours after surgery. Both crude and propensity score-adjusted logistic regression analyses were performed to estimate the odds ratio for developing ARDS in aspirin users. Subgroups were analyzed to determine whether preoperative aspirin use might be associated with improved oxygenation in patients with specific risk factors for lung injury. Of the 375 patients who had aortic valve replacement surgery during the study period, 181 patients took aspirin preoperatively (48.3%) with most taking a dose of 81 mg (72.0%). There were 22 cases of ARDS in the cohort (5.5%). There was no significant difference in the rate of ARDS between aspirin users and nonusers (5.0% vs 6.7%, P = 0.52). There was also no significant difference in the nadir PaO2/FIO2 ratio between aspirin users and nonusers (P = 0.12). The crude odds ratio for ARDS in aspirin users was 0.725 (99% confidence interval, 0.229-2.289; P = 0.47), and the propensity score-adjusted odds ratio was 0.457 (99% confidence interval, 0.120-1.730; P = 0.13). Within the constraints of this analysis that included only 22 affected patients, preoperative aspirin use was not associated with a decreased incidence of ARDS after aortic valve replacement surgery or improved oxygenation.

  5. Immune checkpoints PVR and PVRL2 are prognostic markers in AML and their blockade represents a new therapeutic option.

    PubMed

    Stamm, Hauke; Klingler, Felix; Grossjohann, Eva-Maria; Muschhammer, Jana; Vettorazzi, Eik; Heuser, Michael; Mock, Ulrike; Thol, Felicitas; Vohwinkel, Gabi; Latuske, Emily; Bokemeyer, Carsten; Kischel, Roman; Dos Santos, Cedric; Stienen, Sabine; Friedrich, Matthias; Lutteropp, Michael; Nagorsen, Dirk; Wellbrock, Jasmin; Fiedler, Walter

    2018-05-31

    Immune checkpoints are promising targets in cancer therapy. Recently, poliovirus receptor (PVR) and poliovirus receptor-related 2 (PVRL2) have been identified as novel immune checkpoints. In this investigation we show that acute myeloid leukemia (AML) cell lines and AML patient samples highly express the T-cell immunoreceptor with Ig and ITIM domains (TIGIT) ligands PVR and PVRL2. Using two independent patient cohorts, we could demonstrate that high PVR and PVRL2 expression correlates with poor outcome in AML. We show for the first time that antibody blockade of PVR or PVRL2 on AML cell lines or primary AML cells or TIGIT blockade on immune cells increases the anti-leukemic effects mediated by PBMCs or purified CD3 + cells in vitro. The cytolytic activity of the BiTE® antibody construct AMG 330 against leukemic cells could be further enhanced by blockade of the TIGIT-PVR/PVRL2 axis. This increased immune reactivity is paralleled by augmented secretion of Granzyme B by immune cells. Employing CRISPR/Cas9-mediated knockout of PVR and PVRL2 in MV4-11 cells, the cytotoxic effects of antibody blockade could be recapitulated in vitro. In NSG mice reconstituted with human T cells and transplanted with either MV4-11 PVR/PVRL2 knockout or wildtype cells, prolonged survival was observed for the knockout cells. This survival benefit could be further extended by treating the mice with AMG 330. Therefore, targeting the TIGIT-PVR/PVRL2 axis with blocking antibodies might represent a promising future therapeutic option in AML.

  6. Robotic artificial chordal replacement for repair of mitral valve prolapse.

    PubMed

    Brunsting, Louis A; Rankin, J Scott; Braly, Kimberly C; Binford, Robert S

    2009-07-01

    Artificial chordal replacement (ACR) has emerged as a superior method of mitral valve repair with excellent early and late efficacy. It is also ideal to combine with robotic techniques for correction of mitral prolapse, and this article presents a current method of robotic Gore-Tex ACR. Patients with isolated posterior leaflet prolapse are approached with the fourth-generation DaVinci robotic system and endoaortic balloon occlusion. A pledgetted anchor stitch is placed in a papillary muscle, and a 2-o Gore-Tex suture is passed through the anchor pledget. After full annuloplasty ring placement, the Gore-Tex suture is woven into the prolapsing segment and positioned temporarily with robotic forceps. Chordal length is then "adjusted" by lengthening or shortening the temporary knot over 1-cm increments as the valve is tested by injection of cold saline into the ventricle. After achieving good leaflet position and valve competence, the chord is tied permanently. The "adjustable" ACR procedure preserves leaflet surface area and produces a competent valve in the majority of patients. Postoperative transesophageal echo shows a large surface area of coaptation. Patient recovery is facilitated by the minimally invasive approach, while long-term stability of similar open ACR techniques have been excellent with a 2% to 3% failure rate over 10 years of follow-up. Robotic Gore-Tex ACR without leaflet resection is a reproducible procedure that simplifies mitral repair for prolapse. The outcomes observed in early robotic applications have been excellent. It is suggested that most patients with simple prolapse might validly be approached in this manner.

  7. The effect of postoperative medical treatment on left ventricular mass regression after aortic valve replacement.

    PubMed

    Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V

    2015-03-01

    The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  8. The effects of contrast media volume on acute kidney injury after transcatheter aortic valve replacement: a systematic review and meta-analysis.

    PubMed

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Podboy, Alexander J; Gillaspie, Erin A; Greason, Kevin L; Kashani, Kianoush B

    2016-11-01

    The goal of this systematic review was to assess the effects of contrast media volume on transcatheter aortic valve replacement-related acute kidney injury. A literature search was performed using Medline, EMbase, the Cochrane Database of Systematic Reviews, and clinicaltrials.gov from the inception of these databases through December 2015. Studies that reported relative risk, odds ratio, or hazard ratio comparing the risks of acute kidney injury following transcatheter aortic valve replacement in patients who received high contrast media volume were included. Pooled risk ratio (RR) and 95% confidence intervals (95% CI) were calculated using a random-effect, generic inverse variance method. Four cohort studies composed of 891 patients were included in the analyses to assess the risk of acute kidney injury after transcatheter aortic valve replacement in patients who received high contrast media volume. The pooled RR of acute kidney injury after transcatheter aortic valve replacement in patients who received a large volume of contrast media was 1.41 (95% CI, 0.87 to 2.28) compared with low contrast media volume. The meta-analysis was limited to studies using standard acute kidney injury definitions, and the pooled RR of acute kidney injury in patients who received high contrast media volume is 1.12 (95% CI, 0.78 to 1.62). Our meta-analysis shows no significant association between contrast media volume and risk of acute kidney injury after transcatheter aortic valve replacement. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  9. Outcomes following transcatheter aortic valve replacement in patients with native aortic valve regurgitation

    PubMed Central

    Bob-Manuel, Tamunoinemi; Kadire, Siri; Heckle, Mark R.; Wang, Jiajing

    2018-01-01

    Due to the absence of annular calcification for device anchoring, it is presumed that transcatheter aortic valve replacement (TAVR) is not suitable for the treatment of native aortic valve regurgitation (NAVR) resulting in very limited data and experience concerning its safety and efficacy. We sought to review published data on the safety and efficacy of TAVR in high-risk patients with NAVR. Studies including case reports, case series and original articles published between 2002 and 2016 on TAVR in patients with NAVR were identified with a systematic electronic search using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Only studies reporting data on demographic and procedural characteristics, management and follow up outcomes were analyzed. A total of 30 publications describing 182 patients were identified. Most patients (54%) were men, with a mean age of 70.1±2.6 years, mean logistic European System for Cardiac Operative Risk Evaluation score (EuroSCORE) of 21.8%±4.5% and mean Society of Thoracic Surgeons (STS) score of 8%±1.8% for mortality. The majority (87%) of patients had severe NAVR with no valvular calcification. TAVR was mostly performed through the femoral (58.8%) and apical (33.1%) approach. Device success, defined by VARC-2, was achieved in 86.3% of our study population. A second valve was required in 17 patients (9.3%) during the index procedure for residual aortic regurgitation or malposition. Post-procedure aortic regurgitation of grade 1 or less was present in 80 patients (81%). Pacemaker implantation was required post procedure in 17 patients (9.3%). The 30-day and 1-year mortality was 11.9% and 16.2%, respectively. TAVR is associated with favorable pacemaker implantation and 1-year mortality rates with a high 30-day mortality among selected patients with NAVR. PMID:29404354

  10. Concomitant replacement of the dilated ascending aorta during aortic valve replacement; does it increase the perioperative morbidity and mortality risks?

    PubMed

    Lim, Ju Y; Jung, Sung H; Kim, Joon B; Kim, Dong K; Chung, Cheol H; Song, Hyun; Lee, Jae W; Choo, Suk J

    2013-05-01

    Concerns of increased surgical risks with ascending aortic replacement have led surgeons to manage post-stenotic aortic dilatation more conservatively during aortic valve replacement (AVR). The present study aimed to assess the prognostic implications and surgical risks of replacing the dilated aorta during AVR. Between January 1999 and March 2010, 134 patients who received surgery for aortic stenosis and post-stenotic dilatation (aorta size ≥40 mm) were included in the present study. AVR was performed in 92 patients (AVR group) while aortic valve and ascending aorta replacement (AVR + aorta group) were performed in 42 patients. Overall survival was compared between the two groups using Cox proportional hazard model after adjustment with inverse-probability-of-treatment weighting. The mean follow-up duration was 3.5 ± 3 years. There were no significant differences in the operative mortality and morbidity between the two groups. The late cardiac deaths were also not significantly different between the two groups (p = 1.00). In the AVR group, the ascending aortic expansion rate which was 0.18 mm/year over a mean follow-up duration of 2.3 ± 2.2 years by echocardiography showed a positive correlation with time (r = 0.3, p = 0.08). A relatively greater aortic expansion rate was identified as a risk factor for late mortality (p = 0.015, HR 1.08 (CI: 1.02 to 1.15). Concomitant replacement of the dilated ascending aorta during AVR did not increase the immediate postoperative morbidity or mortality risks and tended to exert a long-term beneficial effect on the risk of late mortality. © 2013 Wiley Periodicals, Inc.

  11. Effect of tricuspid regurgitation and the right heart on survival after transcatheter aortic valve replacement: insights from the Placement of Aortic Transcatheter Valves II inoperable cohort.

    PubMed

    Lindman, Brian R; Maniar, Hersh S; Jaber, Wael A; Lerakis, Stamatios; Mack, Michael J; Suri, Rakesh M; Thourani, Vinod H; Babaliaros, Vasilis; Kereiakes, Dean J; Whisenant, Brian; Miller, D Craig; Tuzcu, E Murat; Svensson, Lars G; Xu, Ke; Doshi, Darshan; Leon, Martin B; Zajarias, Alan

    2015-04-01

    Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (P<0.001). Increasing severity of RV dysfunction as well as right atrial and RV enlargement were also associated with increased mortality (P<0.001). After multivariable adjustment, severe TR (hazard ratio, 3.20; 95% confidence interval, 1.50-6.82; P=0.003) and moderate TR (hazard ratio, 1.60; 95% confidence interval, 1.02-2.52; P=0.042) remained associated with increased mortality as did right atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether

  12. Outcomes of Transcatheter and Surgical Aortic Valve Replacement in Patients on Maintenance Dialysis.

    PubMed

    Alqahtani, Fahad; Aljohani, Sami; Boobes, Khaled; Maor, Elad; Sherieh, Assem; Rihal, Charanjit S; Holmes, David R; Alkhouli, Mohamad

    2017-12-01

    The introduction of transcatheter aortic valve replacement (TAVR) expanded definitive therapy of aortic stenosis to many high-risk patients, but it has not been fully evaluated in the dialysis population. We aimed to evaluate the current trend and in-hospital outcome of surgical aortic valve replacement (SAVR) and TAVR in the dialysis population. Severe aortic stenosis patients on maintenance dialysis who underwent SAVR or TAVR in the Nationwide Inpatient Sample database from January 1, 2005, through December 31, 2014, were included in our comparative analysis. The trends of SAVR and TAVR were assessed. In-hospital mortality, rates of major adverse events, hospital length of stay, cost of care, and intermediate care facility utilization were compared between the 2 groups using both unadjusted and propensity-matched data. Utilization of aortic valve replacement in dialysis patients increased 3-fold; a total of 2531 dialysis patients who underwent either SAVR (n = 2264) or TAVR (n = 267) between 2005 and 2014 were identified. Propensity score matching yielded 197 matched pairs. After matching, a 2-fold increase in in-hospital mortality was found with SAVR compared with TAVR (13.7% vs 6.1%, P = .021). Patients who underwent TAVR had more permanent pacemaker implantation (13.2% vs 5.6%, P = .012) but less blood transfusion (43.7% vs 56.8%, P = .02). Rates of other key morbidities were similar. Hospital length of stay (19 ± 16 vs 11 ± 11 days, P <.001) and non-home discharges (44.7% vs 31.5%, P = .002) were significantly higher with SAVR. Cost of hospitalization was 25% less with TAVR. In patients on maintenance dialysis, TAVR is associated with lower hospital mortality, resource utilization, and cost in comparison with SAVR. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Recent Development in Pulmonary Valve Replacement after Tetralogy of Fallot Repair: The Emergence of Hybrid Approaches

    PubMed Central

    Suleiman, Tariq; Kavinsky, Clifford J.; Skerritt, Clare; Kenny, Damien; Ilbawi, Michael N.; Caputo, Massimo

    2015-01-01

    An increasing number of patients with tetralogy of Fallot require repeat surgical intervention for pulmonary valve replacement secondary to pulmonary regurgitation. Catheter-based interventions have emerged as an attractive alternative to surgery in this patient population but it is limited by patient size or the anatomy of the right ventricular outflow tract. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. The purpose of this review is to highlight the recent advances in the hybrid field of pulmonary valve replacement, summarizing the advantages and disadvantages of the “traditional” surgical and the new catheter-based techniques and discuss the direction future research should take to determine the optimal management for individual patients. PMID:26082929

  14. Aortic valve replacement in a patient with severe nickel allergy.

    PubMed

    Lusini, Mario; Barbato, Raffaele; Spadaccio, Cristiano; Chello, Massimo

    2011-11-01

    Nickel allergy can raise clinical problems in patients undergoing cardiac surgery who require sternal closure with stainless steel wire. We describe the case of a 51-year-old woman with severe nickel allergy who underwent aortic valve replacement with a nickel-free ON-X prosthesis and sternal closure by Fiberwire # 2 suture without complications. Considering its biocompatibility and its mechanical characteristics including optimal strength and knot resistance, this suture might be a viable alternative in patients in which the use of stainless steel wire is contraindicated. © 2011 Wiley Periodicals, Inc.

  15. Standardized methodology for transfemoral transcatheter aortic valve replacement with the Edwards Sapien XT valve under fluoroscopy guidance.

    PubMed

    Kasel, Albert M; Shivaraju, Anupama; Schneider, Stephan; Krapf, Stephan; Oertel, Frank; Burgdorf, Christof; Ott, Ilka; Sumer, Christian; Kastrati, Adnan; von Scheidt, Wolfgang; Thilo, Christian

    2014-09-01

    To provide a simplified, standardized methodology for a successful transfemoral transcatheter aortic valve replacement (TAVR) procedure with the Sapien XT valve in patients with severe aortic stenosis (AS). TAVR is currently reserved for patients with severe, symptomatic AS who are inoperable or at high operative risk. In many institutions, TAVR is performed under general anesthesia with intubation or with conscious sedation. In addition, many institutions still use transesophageal echo (TEE) during the procedure for aortic root angulations and positioning of the valve prior to implantation. Methods. We enrolled 100 consecutive patients (mean age, 80 ± 7 years; range, 50-94 years; female n=59) with severe symptomatic AS. Annulus measurements were based on computed tomography angiograms. All patients underwent fluoroscopy-guided transfemoral TAVR with little to no sedation and without simultaneous TEE. TAVR was predominantly performed with the use of local and central analgesics; only 36% of our cohort received conscious sedation. Procedural success of TAVR was 99%. Transthoracic echocardiography before discharge excluded aortic regurgitation (AR) >2 in all patients (AR >1; n=6). In-hospital stroke rate was 6%. The vessel closure system was successfully employed in 96%. Major vascular complication rate was 1%. The 30-day mortality was 2%. Fluoroscopy-guided TAVR with the use of just analgesics with or without conscious sedation is safe and effective, and this potentially enables a more time-effective and cost-effective procedure. This paper provides simplified, stepwise guidance on how to perform transfemoral TAVR with the Sapien XT valve.

  16. Planar biaxial testing of heart valve cusp replacement biomaterials: Experiments, theory and material constants.

    PubMed

    Labrosse, Michel R; Jafar, Reza; Ngu, Janet; Boodhwani, Munir

    2016-11-01

    Aortic valve (AV) repair has become an attractive option to correct aortic insufficiency. Yet, cusp reconstruction with various cusp replacement materials has been associated with greater long-term repair failures, and it is still unknown how such materials mechanically compare with native leaflets. We used planar biaxial testing to characterize six clinically relevant cusp replacement materials, along with native porcine AV leaflets, to ascertain which materials would be best suited for valve repair. We tested at least six samples of: 1) fresh autologous porcine pericardium (APP), 2) glutaraldehyde fixed porcine pericardium (GPP), 3) St Jude Medical pericardial patch (SJM), 4) CardioCel patch (CC), 5) PeriGuard (PG), 6) Supple PeriGuard (SPG) and 7) fresh porcine AV leaflets (PC). We introduced efficient displacement-controlled testing protocols and processing, as well as advanced convexity requirements on the strain energy functions used to describe the mechanical response of the materials under loading. The proposed experimental and data processing pipeline allowed for a robust in-plane characterization of all the materials tested, with constants determined for two Fung-like hyperelastic, anisotropic strain energy models. Overall, CC and SPG (respectively PG) patches ranked as the closest mechanical equivalents to young (respectively aged) AV leaflets. Because the native leaflets as well as CC, PG and SPG patches exhibit significant anisotropic behaviors, it is suggested that the fiber and cross-fiber directions of these replacement biomaterials be matched with those of the host AV leaflets. The long-term performance of cusp replacement materials would ideally be evaluated in large animal models for AV disease and cusp repair, and over several months or more. Given the unavailability and impracticality of such models, detailed information on stress-strain behavior, as studied herein, and investigations of durability and valve dynamics will be the best surrogates

  17. [Papillary muscle rupture complicating acute myocardial infarction--treatment with mitral valve replacement and coronary bypass surgery in acute phase].

    PubMed

    Kyo, S; Miyamoto, N; Yokote, Y; Ueda, K; Takamoto, S; Omoto, R

    1996-06-01

    Complete rupture of a papillary muscle following acute myocardial infarction is a severe complication that is typically associated with acute left ventricular failure, pulmonary edema, and relentless clinical deterioration. The reported mortality rates without surgical intervention is almost 90%, therefore, prompt operation without prolonged attempts at medical stabilization is the key to decrease operative mortality. Although the complete coronary revascularization in conjunction with mitral valve replacement is advocated in the western medical academic society, there is only a few case of conjunct surgery has been reported in Japan. Three successful cases of conjunct surgery of mitral valve replacement and coronary complete revascularization in acute phase within one week from the onset of acute myocardial infarction (AMI) are described. There were one male and two female patients with an average age of 60-year-old (range 48-67), who developed cardiogenic shock and admitted to our hospital. The average interval between onset of AMI and the appearance of mitral regurgitation (MR) was 38 hours, and that of the appearance of MR and admission was 40 hours. Surgeries were performed within 26 hours (average 13 hours) after admission. The mitral valve was replaced with a mechanical valve (St. Jude Medical Valve) and a complete coronary revasculatization was done using saphenous vein graft. The average period of operation time and aortic cross clamping time were 6 hours 22 minutes and 109 minutes respectively. The average number of coronary grafting was 2.3 (range 1-3). Postoperative recovery from cardiogenic shock was uneventful in all three patients. The average periods of ICU stay and hospital stay were 5 days and 43 days respectively. All patients have regained their social activities with mean follow up period of 52 months. Since ischemic heart disease remains the leading cause of death in such patients, it is suggested that complete coronary revascularization

  18. A cost-utility analysis of transcatheter versus surgical aortic valve replacement for the treatment of aortic stenosis in the population with intermediate surgical risk.

    PubMed

    Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C

    2018-05-01

    Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the

  19. Mid- to long-term outcome comparison of the Medtronic Hancock II and bi-leaflet mechanical aortic valve replacement in patients younger than 60 years of age: a propensity-matched analysis.

    PubMed

    Wang, Yin; Chen, Si; Shi, Jiawei; Li, Geng; Dong, Nianguo

    2016-03-01

    This study aims to compare mid-long-term clinical outcomes between patients younger than 60 years of age undergoing bioprosthetic and mechanical aortic valve replacement. From January 2002 to December 2009, patients younger than 60 years of age who received Medtronic Hancock II porcine bioprostheses were selected and compared with those who received mechanical bi-leaflet valves in the aortic position. A stepwise logistic regression propensity score identified a subset of 112 evenly matched patient-pairs. Mid-long-term outcomes of survival, valve-related reoperations, thromboembolic events and bleeding events were assessed. The follow-up was only 95.1% complete. Fourteen measurable variables were statistically similar for the matched cohort. Postoperative in-hospital mortality was 3.6% (bioprosthetic valves) and 2.7% (mechanical valves) (P = 0.700). Survival at 5 and 10 years was 96.3 and 88.7% for patients receiving bioprosthetic valve replacement versus 96.3 and 87.9% for patients receiving mechanical valve replacement (P = 0.860), respectively. At 5 and 10 years after operations, freedom from valve-related reoperation was 97.2 and 94.8% for patients receiving mechanical valve replacement, and 96.3 and 90.2% for patients receiving bioprosthetic valve replacement (P = 0.296), respectively. There was no difference between freedom from thromboembolic events (P = 0.528) and bleeding events (P = 0.128) between the matched groups during the postoperative 10 years. In patients younger than 60 years of age undergoing aortic valve replacement, mid-long-term survival rate was similar for patients receiving bioprosthetic versus mechanical valve replacement. Bioprosthetic valves were associated with a trend for a lower risk of anticoagulation treatment and did not have significantly greater likelihood of a reoperation. These findings suggest that a bioprosthetic valve may be a reasonable choice for AVR in patients younger than 60 years of age. © The Author 2015. Published by

  20. Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis.

    PubMed

    Oda, Takeshi; Kato, Seiya; Tayama, Eiki; Fukunaga, Shuji; Akashi, Hidetoshi; Aoyagi, Shigeaki

    2009-01-01

    A Carpentier-Edwards pericardial (CEP) bioprosthesis was explanted from an 81-year-old woman due to nonstructural dysfunction 9 years after mitral valve replacement. The nonstructural dysfunction produced severe regurgitation in the mitral position. During the surgery, excessive pannus overgrowth was seen on the left ventricular side of the CEP bioprosthesis. Pannus overgrowth was prominent on one leaflet. That leaflet was stiff and shortened due to the excessive overgrowth of pannus. In this patient, the distortion of one leaflet was the main reason for transvalvular leakage of the CEP bioprosthesis in the mitral position. A new CEP bioprosthesis was implanted in the mitral position. Pathological analysis revealed fibrotic pannus with a small amount of cellular material over the leaflets of the resected CEP valve. This change was marked on the distorted leaflet.

  1. Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass

    PubMed Central

    Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian

    2016-01-01

    This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. PMID:27694613

  2. [Evaluation of the antithrombotic strategy in low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis].

    PubMed

    Aceves-Velázquez, Eduardo; Vieyra-Herrera, Gerardo; Rodríguez-Chávez, Laura; Herrera-Alarcón, Valentín

    2017-07-16

    According to current guidelines, in patients without additional risk factors who have undergone aortic valve replacement with a bioprosthesis, anticoagulation in the first 3 months after surgery is still a matter of debate. According to current evidence, aspirin in low doses is a reasonable alternative to vitamin K antagonists (VKA). A comparison is made between the incidence of thrombotic and haemorrhagic complications in patients with low thrombotic risk who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico. The hypothesis: aspirin as monotherapy has a beneficial effect compared to VKA. The studied patients were the low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico from 2011 to 2015. The groups studied were: aspirin only, VKA only, and the combination of VKA plus aspirin. The patients were retrospectively followed-up for 12 months, and the thrombotic and haemorrhagic complications were documented. Of the 231 patients included in the study, only one patient in the VKA only group presented with a haemorrhagic complication. No thrombotic complications were observed. In the present study no thrombotic complications were observed in patients who did not receive anticoagulation in the first 3 months after an aortic valve replacement with a bioprosthesis after a follow up period of 12 months. This suggests that the use of aspirin only is safe during this period. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  3. [Aortic Valve Replacement after Balloon Valvuloplasty for Aortic Valve Stenosis in a Dialysis Patient with Cardiogenic Shock;Report of a Case].

    PubMed

    Takamatsu, Masanori; Hirotani, Takashi; Ohtsubo, Satoshi; Saito, Sumikatsu; Takeuchi, Shigeyuki; Hasegawa, Tasuku; Endo, Ayaka; Yamasaki, Yu; Hayashida, Kentaro

    2015-06-01

    A 67-year-old man on chronic hemodialysis was admitted with worsening congestive heart failure due to critical aortic stenosis. Echocardiography showed severe aortic stenosis with a valve area of 0.67 cm2 and an ejection fraction of 0.31. Cardiac catheterization revealed severe pulmonary hypertension with pulmonary artery pressures of 62/32 mmHg. In the middle of cardiac catheterization, the systolic pressure declined to 60 mmHg due to cardiogenic shock. Dopamine hydrochloride and dobutamine hydrochloride infusions were necessary to maintain a systolic pressure greater than 80 mmHg. Balloon aortic valvuloplasty was urgently performed. The patient's symptoms rapidly resolved except for angina on exertion. One month later, elective aortic valve replacement was performed. The postoperative course was uneventful and the he was discharged on the 60th postoperative day. A follow-up echocardiogram 6 months postoperatively revealed normal prosthetic valve function and an ejection fraction of 0.6.

  4. PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI.

    PubMed

    Alansary, Amir; Rajchl, Martin; McDonagh, Steven G; Murgasova, Maria; Damodaram, Mellisa; Lloyd, David F A; Davidson, Alice; Rutherford, Mary; Hajnal, Joseph V; Rueckert, Daniel; Kainz, Bernhard

    2017-10-01

    In this paper, we present a novel method for the correction of motion artifacts that are present in fetal magnetic resonance imaging (MRI) scans of the whole uterus. Contrary to current slice-to-volume registration (SVR) methods, requiring an inflexible anatomical enclosure of a single investigated organ, the proposed patch-to-volume reconstruction (PVR) approach is able to reconstruct a large field of view of non-rigidly deforming structures. It relaxes rigid motion assumptions by introducing a specific amount of redundant information that is exploited with parallelized patchwise optimization, super-resolution, and automatic outlier rejection. We further describe and provide an efficient parallel implementation of PVR allowing its execution within reasonable time on commercially available graphics processing units, enabling its use in the clinical practice. We evaluate PVR's computational overhead compared with standard methods and observe improved reconstruction accuracy in the presence of affine motion artifacts compared with conventional SVR in synthetic experiments. Furthermore, we have evaluated our method qualitatively and quantitatively on real fetal MRI data subject to maternal breathing and sudden fetal movements. We evaluate peak-signal-to-noise ratio, structural similarity index, and cross correlation with respect to the originally acquired data and provide a method for visual inspection of reconstruction uncertainty. We further evaluate the distance error for selected anatomical landmarks in the fetal head, as well as calculating the mean and maximum displacements resulting from automatic non-rigid registration to a motion-free ground truth image. These experiments demonstrate a successful application of PVR motion compensation to the whole fetal body, uterus, and placenta.

  5. Aortic valve replacement in a dialysis-dependent Jehovah's Witness: successful use of a minicircuit, microplegia, and multimodality blood conservation technique

    PubMed Central

    Sutton, Steve W.; Marcel, Randy

    2007-01-01

    We present the first reported case of an aortic valve replacement operation without blood transfusion in a 62-year-old Jehovah's Witness with dialysis-dependent chronic renal failure, severe anemia, severe aortic stenosis, and symptomatic angina with minimal exertion after an accident in which she suffered fractures of both her right arm and leg. She underwent successful valve replacement surgery after preoperative stabilization of her fractures and high-dose erythropoietin and iron supplement therapy preoperatively and postoperatively. The intraoperative blood conservation technique included a novel approach with a miniature cardiopulmonary bypass circuit and microplegia with limited hemodilution. High-risk valve surgery in patients who are Jehovah's Witnesses can be successful with a carefully planned multimodality blood conservation strategy. PMID:17256040

  6. [Anesthesia for total and descending aorta replacement and aortic valve replacement for post-repair aneurysm of coarctation of aorta and aortic stenosis].

    PubMed

    Furuichi, Yuko; Shimizu, Jun; Sakamoto, Atsuhiro

    2012-04-01

    We experienced anesthesia for total arch and descending aorta replacement and aortic valve replacement for post-repair aneurysm of coarctation of aorta and aortic stenosis. Because there was possibility that post coarctectomy syndrome would occur after repair of coarctation of aorta, administration of depressor that acts on renin-angiotensin-aldosterone and careful observation were needed postoperatively. In consideration of the development of collateral vessels, preoperative imaging evaluation was added and operative method in cardiopulmonary bypass was adjusted. Careful preoperative evaluation is very important in cardiac anesthesia.

  7. Aortic valve replacement and repair of left ventricular pseudoaneurysm in a Jehovah’s Witness

    PubMed Central

    Perrotti, Andrea; Vaislic, Claude; Chocron, Sidney

    2013-01-01

    The preoperative and surgical management of a giant left ventricular pseudoaneurysm(LVP) associated with aortic valve replacement in a 76 year old male Jehovah’s Witness patient is reported. The satisfactory recovery observed in this patient demonstrates the feasibility of this complex surgical procedure even in this particular patient population. PMID:25478494

  8. Assessment of Hemodynamic Conditions in the Aorta Following Root Replacement with Composite Valve-Conduit Graft.

    PubMed

    Cheng, Zhuo; Kidher, Emaddin; Jarral, Omar A; O'Regan, Declan P; Wood, Nigel B; Athanasiou, Thanos; Xu, Xiao Yun

    2016-05-01

    This paper presents the analysis of detailed hemodynamics in the aortas of four patients following replacement with a composite bio-prosthetic valve-conduit. Magnetic resonance image-based computational models were set up for each patient with boundary conditions comprising subject-specific three-dimensional inflow velocity profiles at the aortic root and central pressure waveform at the model outlet. Two normal subjects were also included for comparison. The purpose of the study was to investigate the effects of the valve-conduit on flow in the proximal and distal aorta. The results suggested that following the composite valve-conduit implantation, the vortical flow structure and hemodynamic parameters in the aorta were altered, with slightly reduced helical flow index, elevated wall shear stress and higher non-uniformity in wall shear compared to normal aortas. Inter-individual analysis revealed different hemodynamic conditions among the patients depending on the conduit configuration in the ascending aorta, which is a key factor in determining post-operative aortic flow. Introducing a natural curvature in the conduit to create a smooth transition between the conduit and native aorta may help prevent the occurrence of retrograde and recirculating flow in the aortic arch, which is particularly important when a large portion or the entire ascending aorta needs to be replaced.

  9. Triple valve surgery: a 25-year experience.

    PubMed

    Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen

    2004-09-01

    Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become

  10. Transcatheter aortic valve replacement

    MedlinePlus

    ... fully will restrict blood flow. This is called aortic stenosis. If there is also a leak, it is ... TAVR is used for people with severe aortic stenosis who aren't ... valve . In adults, aortic stenosis usually occurs due to calcium ...

  11. Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass.

    PubMed

    Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian

    2016-12-01

    This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. © The Author(s) 2016.

  12. Robot-assisted real-time magnetic resonance image-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    Real-time magnetic resonance imaging (rtMRI)-guided transcatheter aortic valve replacement (TAVR) offers improved visualization, real-time imaging, and pinpoint accuracy with device delivery. Unfortunately, performing a TAVR in a MRI scanner can be a difficult task owing to limited space and an awkward working environment. Our solution was to design a MRI-compatible robot-assisted device to insert and deploy a self-expanding valve from a remote computer console. We present our preliminary results in a swine model. We used an MRI-compatible robotic arm and developed a valve delivery module. A 12-mm trocar was inserted in the apex of the heart via a subxiphoid incision. The delivery device and nitinol stented prosthesis were mounted on the robot. Two continuous real-time imaging planes provided a virtual real-time 3-dimensional reconstruction. The valve was deployed remotely by the surgeon via a graphic user interface. In this acute nonsurvival study, 8 swine underwent robot-assisted rtMRI TAVR for evaluation of feasibility. Device deployment took a mean of 61 ± 5 seconds. Postdeployment necropsy was performed to confirm correlations between imaging and actual valve positions. These results demonstrate the feasibility of robotic-assisted TAVR using rtMRI guidance. This approach may eliminate some of the challenges of performing a procedure while working inside of an MRI scanner, and may improve the success of TAVR. It provides superior visualization during the insertion process, pinpoint accuracy of deployment, and, potentially, communication between the imaging device and the robotic module to prevent incorrect or misaligned deployment. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Comparison of the structure of the aortic valve and ascending aorta in adults having aortic valve replacement for aortic stenosis versus for pure aortic regurgitation and resection of the ascending aorta for aneurysm.

    PubMed

    Roberts, William Clifford; Vowels, Travis James; Ko, Jong Mi; Filardo, Giovanni; Hebeler, Robert Frederick; Henry, Albert Carl; Matter, Gregory John; Hamman, Baron Lloyd

    2011-03-01

    There is debate concerning whether an aneurysmal ascending aorta should be replaced when associated with a dysfunctioning aortic valve that is to be replaced. To examine this issue, we divided the patients by type of aortic valve dysfunction-either aortic stenosis (AS) or pure aortic regurgitation (AR)-something not previously undertaken. Of 122 patients with ascending aortic aneurysm (unassociated with aortitis or acute dissection), the aortic valve was congenitally malformed (unicuspid or bicuspid) in 58 (98%) of the 59 AS patients, and in 38 (60%) of the 63 pure AR patients. Ascending aortic medial elastic fiber loss (EFL) (graded 0 to 4+) was zero or 1+ in 53 (90%) of the AS patients, in 20 (53%) of the 38 AR patients with bicuspid valves, and in all 12 AR patients with tricuspid valves unassociated with the Marfan syndrome. An unadjusted analysis showed that, among the 96 patients with congenitally malformed valves, the 38 AR patients had a significantly higher likelihood of 2+ to 4+ EFL than the 58 AS patients (crude odds ratio: 8.78; 95% confidence interval: 2.95, 28.13). These data strongly suggest that the type of aortic valve dysfunction-AS versus pure AR-is very helpful in predicting loss of aortic medial elastic fibers in patients with ascending aortic aneurysms and aortic valve disease.

  14. Long-term results after aortic valve replacement with the Biocor PSB stentless xenograft in the elderly.

    PubMed

    Luciani, G B; Santini, F; Auriemma, S; Barozzi, L; Bertolini, P; Mazzucco, A

    2001-05-01

    This study seeks to define the long-term results after Biocor PSB stentless aortic valve replacement (AVR) in elderly patients, including the effects of No-React treatment. We reviewed the outcomes of 106 consecutive patients, aged 70+/-6 years, having Biocor PSB (93 standard, 13 No-React) AVR between October 1992 and October 1996. There were three early deaths (3%) and 15 late deaths (15%), during a mean follow-up of 5.8+/-1.6 years. At 8 years, survival was 82%+/-4% and freedom from cardiac death was 94%+/-3%. Freedom from valve failure was 92%+/-4% at 8 years (No-React: 92%+/-8% at 4 years). Replacement of the xenograft was required in 5 patients. Freedom from reoperation was 91%+/-4% at 8 years (No-React: 92%+/-8% at 4 years). Four bleeding and two embolic events were recorded: overall valve-related event-free survival was 81%+/-7% at 8 years (No-React: 76%+/-12% at 4 years). Age of long-term survivors averaged 77+/-5 years and their New York Heart Association status was 1.3+/-0.6 (versus 2.9+/-0.6 preoperatively, p = 0.01). Satisfactory freedom from cardiac events and from valve deterioration added to uniform improvement in functional status despite advanced age and high prevalence of comorbid conditions make AVR with the Biocor PSB xenograft a valid long-term therapy for the elderly. No-React treatment does not influence xenograft durability.

  15. Valve-sparing aortic root replacement in patients with Marfan syndrome enrolled in the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions.

    PubMed

    Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A

    2014-05-01

    The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.

  16. Minimally invasive aortic valve replacement in high risk patient groups

    PubMed Central

    Lewis, Harriet; Benedetto, Umberto; Caputo, Massimo; Angelini, Gianni; Vohra, Hunaid A.

    2017-01-01

    Minimally invasive aortic valve replacement (AVR) aims to preserve the sternal integrity and improve postoperative outcomes. In low risk patients, this technique can be achieved with comparable mortality to the conventional approach and there is evidence of possible reduction in intensive care and hospital length of stay, transfusion requirement, renal dysfunction, improved respiratory function and increased patient satisfaction. In this review, we aim to asses if these benefits can be transferred to the high risk patient groups. We therefore, discuss the available evidence for the following high risk groups: elderly patients, re-operative surgery, poor lung function, pulmonary hypertension, obesity, concomitant procedures and high risk score cohorts. PMID:28740685

  17. Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients.

    PubMed

    McClure, R Scott; Narayanasamy, Narendren; Wiegerinck, Esther; Lipsitz, Stuart; Maloney, Ann; Byrne, John G; Aranki, Sary F; Couper, Gregory S; Cohn, Lawrence H

    2010-05-01

    This study reviews a single institution experience with the Carpentier-Edwards pericardial aortic valve bioprosthesis, concentrating on late outcomes. From December 1991 to June 2002, 1,000 patients underwent aortic valve replacement with the Carpentier-Edwards pericardial valve (mean follow-up 6.01 +/- 3.56 years). The institutional database was reviewed. Follow-up data were acquired through telephone interviews and mail-in questionnaires. Time-to-event analyses were performed by the Kaplan-Meier method. Mean age was 74.1 years; 545 patients (54.5%) were male. Mean preoperative ejection fraction was 52.5%. Isolated aortic valve replacement occurred in 372 cases (37.2%). Combined aortic valve replacement with coronary artery bypass grafting occurred in 443 cases (44.3%). The remaining 185 patients (18.5%) underwent complex procedures with concomitant mitral, tricuspid, or arch repair. One hundred forty patients (14.0%) had prior aortic valve surgery. Follow-up was 99.4% complete. Overall operative mortality was 7.2% (72 of 1,000). There were 503 late deaths (50.3%). Age-stratified survival at 15 years was 43.7% for patients less than 65 years of age; 18.2% for patients aged 65 to 75; and 9.4% for patients aged more than 75 years. There were 26 failed bioprostheses (2.6%) requiring reoperation. Structural valve deterioration was the cause in 13 of 26 cases (50%), endocarditis in 11 of 26 (42%), and perivalvular leak in 2 of 26 (7.6%). Age-stratified freedom from reoperation due to structural valve deterioration at 15 years was 34.7% for patients less than 65 years of age; 89.4% for patients aged 65 to 75; and 99.5% for patients aged more than 75 years. The Carpentier-Edwards pericardial bioprosthesis shows long-term durability with low rates of structural failure. Copyright (c) 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Transcatheter Aortic Valve Replacement by a Novel Suprasternal Approach.

    PubMed

    Codner, Pablo; Pugliese, Daniel; Kouz, Rémi; Patel, Amisha; Chen, Cheng-Han; Terre, Juan; Eudailey, Kyle W; Nazif, Tamim; Vahl, Torsten P; George, Isaac; Khalique, Omar K; Hahn, Rebecca T; Leon, Martin B; Kodali, Susheel; Borger, Michael

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) provides therapy for patients with severe aortic stenosis at extreme, high, or intermediate surgical risk. Transfemoral access has been the preferred access route; however, this approach is not suitable for many TAVR candidates. A suprasternal approach may allow for earlier ambulation and shorter hospital stay as compared with other, nontransfemoral approaches. A total of 11 patients with unsuitable transfemoral access underwent suprasternal TAVR. Propensity matching was used to compare suprasternal patients to patients undergoing transaortic, transapical, and trans-subclavian TAVR. Groups were well matched for baseline characteristics. A self-expanding valve device was used in 6 (54.5%) and a balloon-expandable valve in 5 (45.5%) of the 11 patients treated by the suprasternal route. Suprasternal and trans-subclavian patients were able to ambulate earlier than patients treated by the transaortic route, a median 1.6 days (interquartile range [IQR]: 0.9 to 1.8), 1.6 days (IQR: 0.9 to 2.7), and 3.9 days (IQR: 1.9 to 4.5) after the procedure for suprasternal, trans-subclavian, and transaortic patients, respectively (p = 0.001). Length of hospitalization was shorter for patients treated by suprasternal or trans-subclavian access in comparison with patients treated by the transaortic or transapical approach: median 4 days (IQR: 3 to 8) and 4 days (IQR: 4 to 8) versus 8 days (IQR: 6 to 14) and 6 days (IQR: 7 to 11) for suprasternal and trans-subclavian versus transaortic and transapical, respectively (p = 0.01). Suprasternal and trans-subclavian access are associated with earlier ambulation and shorter hospitalization than other nontransfemoral TAVR routes, without an increase in complications. Further study is required to determine if suprasternal is the alternative access of choice for TAVR patients with poor transfemoral vasculature. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  19. Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery.

    PubMed

    Popma, Jeffrey J; Adams, David H; Reardon, Michael J; Yakubov, Steven J; Kleiman, Neal S; Heimansohn, David; Hermiller, James; Hughes, G Chad; Harrison, J Kevin; Coselli, Joseph; Diez, Jose; Kafi, Ali; Schreiber, Theodore; Gleason, Thomas G; Conte, John; Buchbinder, Maurice; Deeb, G Michael; Carabello, Blasé; Serruys, Patrick W; Chenoweth, Sharla; Oh, Jae K

    2014-05-20

    This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery. Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effective therapy. We performed a prospective, multicenter, nonrandomized investigation evaluating the safety and efficacy of self-expanding TAVR in patients with symptomatic severe aortic stenosis with prohibitive risks for surgery. The primary endpoint was a composite of all-cause mortality or major stroke at 12 months, which was compared with a pre-specified objective performance goal (OPG). A total of 41 sites in the United States recruited 506 patients, of whom 489 underwent attempted treatment with the CoreValve THV. The rate of all-cause mortality or major stroke at 12 months was 26.0% (upper 2-sided 95% confidence bound: 29.9%) versus 43.0% with the OPG (p < 0.0001). Individual 30-day and 12-month events included all-cause mortality (8.4% and 24.3%, respectively) and major stroke (2.3% and 4.3%, respectively). Procedural events at 30 days included life-threatening/disabling bleeding (12.7%), major vascular complications (8.2%), and need for permanent pacemaker placement (21.6%). The frequency of moderate or severe paravalvular aortic regurgitation was lower 12 months after self-expanding TAVR (4.2%) than at discharge (10.7%; p = 0.004 for paired analysis). TAVR with a self-expanding bioprosthesis was safe and effective in patients with symptomatic severe aortic stenosis at prohibitive risk for surgical valve replacement. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2014 American College of Cardiology Foundation. Published by

  20. The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement

    PubMed Central

    McElhinney, Doff B; Hennesen, Jill T

    2013-01-01

    The Melody® transcatheter pulmonary valve (TPV) is a percutaneous valve system designed for the treatment of obstruction and/or regurgitation of prosthetic conduits placed between the right ventricle and pulmonary arteries in patients with congenital heart disease. In 2000, Melody TPV became the first transcatheter valve implanted in a human; in 2006 it became the first transcatheter valve commercially available anywhere in the world; and in 2010 it was launched as the first commercially available transcatheter valve in the United States. In this review, we present the clinical background against which the Melody valve was developed and implemented, introduce the rationale for and challenges of transcatheter valve technology for this population, outline the history and technical details of its development and use, and summarize currently available data concerning the performance of the device. PMID:23834411

  1. What Is Heart Valve Surgery?

    MedlinePlus

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  2. What Is Heart Valve Disease?

    MedlinePlus

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  3. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    PubMed

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  4. In Vitro Study of Flow Regulation for Pulmonary Insufficiency

    PubMed Central

    Camp, T. A.; Stewart, K. C.; Figliola, R. S.; McQuinn, T.

    2007-01-01

    Given the tolerance of the right heart circulation to mild regurgitation and gradient, we study the potential of using motionless devices to regulate the pulmonary circulation. In addition, we document the flow performance of two mechanical valves. A motionless diode, a nozzle, a mechanical bileaflet valve, and a tilting disk valve were tested in a pulmonary mock circulatory system over the normal human range of pulmonary vascular resistance (PVR). For the mechanical valves, regurgitant fractions (RFs) and transvalvular pressure gradients were found to be weak functions of PVR. On the low end of normal PVR, the bileaflet and tilting disk valves fluttered and would not fully close. Despite this anomaly, the regurgitant fraction of either valve did not change significantly. The values for RF and transvalvular gradient measured varied from 4 to 7% and 4 to 7 mm Hg, respectively, at 5 lpm for all tests. The diode valve was able to regulate flow with mild regurgitant fraction and trivial gradient but with values higher than either mechanical valve tested. Regurgitant fraction ranged from 2 to 17% in tests extending from PVR values of 1 to 4.5 mm Hg/lpm at 5 lpm and with concomitant increases in gradient up to 17 mm Hg. The regurgitant fraction for the nozzle increased from 2 to 23% over the range of PVR with gradients increasing to 18 mm Hg. The significant findings were: (1) the mechanical valves controlled regurgitation at normal physiological cardiac output and PVR even though they failed to close at some normal values of PVR and showed leaflet flutter; and (2) it may be possible to regulate the pulmonary circulation to tolerable levels using a motionless pulmonary valve device. PMID:17408334

  5. Vancouver Transcatheter Aortic Valve Replacement Clinical Pathway: Minimalist Approach, Standardized Care, and Discharge Criteria to Reduce Length of Stay.

    PubMed

    Lauck, Sandra B; Wood, David A; Baumbusch, Jennifer; Kwon, Jae-Yung; Stub, Dion; Achtem, Leslie; Blanke, Philipp; Boone, Robert H; Cheung, Anson; Dvir, Danny; Gibson, Jennifer A; Lee, Bobby; Leipsic, Jonathan; Moss, Robert; Perlman, Gidon; Polderman, Jopie; Ramanathan, Krishnan; Ye, Jian; Webb, John G

    2016-05-01

    We describe the development, implementation, and evaluation of a standardized clinical pathway to facilitate safe discharge home at the earliest time after transfemoral transcatheter aortic valve replacement. Between May 2012 and October 2014, the Heart Team developed a clinical pathway suited to the unique requirements of transfemoral transcatheter aortic valve replacement in contemporary practice. The components included risk-stratified minimalist periprocedure approach, standardized postprocedure care with early mobilization and reconditioning, and criteria-driven discharge home. Our aim was to reduce variation in care, identify a subgroup of patients suitable for early discharge (≤48 hours), and decrease length of stay for all patients. We addressed barriers related to historical practices, complex multidisciplinary stakeholder engagement, and adoption of length of stay as a quality indicator. We retrospectively reviewed the experiences of 393 consecutive patients; 150 (38.2%) were discharged early. At baseline, early discharge patients had experienced less previous balloon aortic valvuloplasty, had higher left ventricular ejection fraction, better cognitive function, and were less frail than the standard discharge group (>48 hours). Early discharge was associated with the use of local anesthesia, implantation of balloon expandable device, avoidance of urinary catheter, and early removal of temporary pacemaker. Median length of stay was 1 day for early discharge and 3 days for other patients; 97.7% were discharged home. There were no differences in 30-day mortality (1.3%), disabling stroke (0.8%), or readmission (10.7%). The implementation of a transcatheter aortic valve replacement clinical pathway shifted the program's approach to combine standardized processes and individual risk stratification. The Vancouver transcatheter aortic valve replacement clinical pathway requires a rigorous assessment to determine its efficacy, safety, and reproducibility.

  6. RNA-dependent RNA polymerase (NIb) of the potyviruses is an avirulence factor for the broad-spectrum resistance gene Pvr4 in Capsicum annuum cv. CM334.

    PubMed

    Kim, Saet-Byul; Lee, Hye-Young; Seo, Seungyeon; Lee, Joo Hyun; Choi, Doil

    2015-01-01

    Potyviruses are one of the most destructive viral pathogens of Solanaceae plants. In Capsicum annuum landrace CM334, a broad-spectrum gene, Pvr4 is known to be involved in resistance against multiple potyviruses, including Pepper mottle virus (PepMoV), Pepper severe mosaic virus (PepSMV), and Potato virus Y (PVY). However, a potyvirus avirulence factor against Pvr4 has not been identified. To identify the avirulence factor corresponding to Pvr4 in potyviruses, we performed Agrobacterium-mediated transient expressions of potyvirus protein coding regions in potyvirus-resistant (Pvr4) and -susceptible (pvr4) pepper plants. Hypersensitive response (HR) was observed only when a RNA-dependent RNA polymerase (NIb) of PepMoV, PepSMV, or PVY was expressed in Pvr4-bearing pepper leaves in a genotype-specific manner. In contrast, HR was not observed when the NIb of Tobacco etch virus (TEV), a virulent potyvirus, was expressed in Pvr4-bearing pepper leaves. Our results clearly demonstrate that NIbs of PepMoV, PepSMV, and PVY serve as avirulence factors for Pvr4 in pepper plants.

  7. Combined low-dose aspirin and warfarin anticoagulant therapy of postoperative atrial fibrillation following mechanical heart valve replacement.

    PubMed

    Wang, Jian-tang; Dong, Ming-feng; Song, Guang-min; Ma, Zeng-shan; Ma, Sheng-jun

    2014-12-01

    The safety and efficacy of combined low dose aspirin and warfarin therapy in patients with atrial fibrillation after mechanical heart valve replacement were evaluated. A total of 1016 patients (620 females, mean age of 36.8±7.7 years) admitted for cardiac valve replacement and complicated with atrial fibrillation after surgery were randomly divided into study (warfarin plus 75-100 mg aspirin) or control (warfarin only) groups. International normalized ratio (INR) and prothrombin time were maintained at 1.8-2.5 and 1.5-2.0 times the normal values, respectively. Thromboembolic events and major bleedings were registered during the follow-up period. Patients were followed up for 24±9 months. The average dose of warfarin in the study and control groups was 2.91±0.83 mg and 2.88±0.76 mg, respectively (P>0.05). The incidence of overall thromboembolic events in study group was lower than that in control group (2.16% vs. 4.35%, P=0.049). No statistically significant differences were found in hemorrhage events (3.53% vs. 3.95%, P=0.722) or mortality (0.20% vs. 0.40%, P=0.559) between the two groups. Combined low dose aspirin and warfarin therapy in the patients with atrial fibrillation following mechanical heart valve replacement significantly decreased thromboembolic events as compared with warfarin therapy alone. This combined treatment was not associated with an increase in the risk of major bleeding or mortality.

  8. Profiling illness perceptions to identify patients at-risk for decline in health status after heart valve replacement.

    PubMed

    Kohlmann, Sebastian; Rimington, Helen; Weinman, John

    2012-06-01

    Identification of risk factors for decline in health status by profiling illness perceptions before and one year after heart valve replacement surgery. Prospective data from N=225 consecutively admitted first time valve replacement patients was assessed before and one year after surgery. Patients were asked about their illness perceptions (Illness Perception Questionnaire-Revised) and mood state (Hospital Anxiety and Depression Scale). Health status was defined by quality of life (Short-Form 36) and New York Heart Association (NYHA) class. Cluster analyses were conducted to identify illness perception profiles over time. Predictors of health status after surgery were analyzed with multivariate methods. Patients were grouped according to the stability and nature (positive, negative) of their illness perception profile over one year. One year after surgery patients holding a negative illness perception profile showed a lower physical quality of life and were diagnosed in a higher New York Heart Association class than patients changing to positive and patients with stable positive illness perceptions (P<.001). Over and above biological determinants, post-surgery physical quality of life and NYHA class were both predicted by pre-surgery illness perception profiles (P<.05). Patients going for heart valve replacement surgery can be easily categorized into illness perception profiles that predict health status one year after surgery. These patients could benefit from early screening as negative illness perceptions are modifiable risk factors. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Concomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.

    PubMed

    Aydin, Unal; Gul, Mehmet; Aslan, Serkan; Akkaya, Emre; Yildirim, Aydin

    2015-04-28

    Transcatheter valve implantation is a novel interventional technique, which was developed as an  alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.

  10. Subprosthetic Pannus after Aortic Valve Replacement Surgery: Cardiac CT Findings and Clinical Features.

    PubMed

    Han, Kichang; Yang, Dong Hyun; Shin, So Youn; Kim, Namkug; Kang, Joon-Won; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won; Lim, Tae-Hwan

    2015-09-01

    To investigate the cardiac computed tomographic (CT) findings and clinical implications of subprosthetic pannus in patients who have undergone aortic valve replacement. The institutional review board approved this retrospective study, and the need to obtain written informed consent was waived. From April 2011 to March 2012, 88 patients (mean age, 63 years; 45 men) with a prosthetic aortic valve who underwent cardiac CT were retrospectively selected. Dynamic cardiac CT images were analyzed by using a multiplanar reformatted technique. The presence or absence of subprosthetic pannus and its extent were evaluated at cardiac CT. The geometric orifice area and the effective orifice area of each prosthetic valve were measured to enable analysis of the pannus encroachment ratio in the systolic phase. Hemodynamic parameters at echocardiography, including mean transprosthetic pressure gradient (MTPG), were compared between patients with and those without pannus. The encroachment ratio and the MTPG were correlated by using the Spearman test to evaluate the relationship between the two variables. Seventeen patients (19%) had subprosthetic pannus at cardiac CT. In patients with subprosthetic pannus, MTPG, peak pressure gradient, transvalvular peak velocity, and left ventricular ejection fraction (LVEF) were significantly higher than in patients without pannus (MTPG: 28.1 mm Hg ± 19.8 [standard deviation] vs 14.0 mm Hg ± 6.5, P = .004; peak pressure gradient: 53.1 mm Hg ± 38.4 vs 26.1 mm Hg ± 11.4, P = .004; transvalvular peak velocity: 3.3 m/sec ± 1.3 vs 2.5 m/sec ± 0.5; and LVEF: 64.7% ± 7.4 vs 56.8% ± 10.5, P = .004). A high MTPG (≥40 mm Hg) was observed in four patients at echocardiography, and subprosthetic panni were identified at CT in all four patients. In patients with increased MTPGs, the encroachment ratio by subprosthetic pannus at CT was significantly higher than that in patients with MTPGs of less than 40 mm Hg (42.7 ± 13.3 vs 7.6 ± 3, P = .012

  11. Calcification Characteristics of Low-Flow Low-Gradient Severe Aortic Stenosis in Patients Undergoing Transcatheter Aortic Valve Replacement

    PubMed Central

    Stähli, Barbara E.; Nguyen-Kim, Thi Dan Linh; Gebhard, Cathérine; Frauenfelder, Thomas; Tanner, Felix C.; Nietlispach, Fabian; Maisano, Francesco; Falk, Volkmar; Lüscher, Thomas F.; Maier, Willibald; Binder, Ronald K.

    2015-01-01

    Low-flow low-gradient severe aortic stenosis (LFLGAS) is associated with worse outcomes. Aortic valve calcification patterns of LFLGAS as compared to non-LFLGAS have not yet been thoroughly assessed. 137 patients undergoing transcatheter aortic valve replacement (TAVR) with preprocedural multidetector computed tomography (MDCT) and postprocedural transthoracic echocardiography were enrolled. Calcification characteristics were assessed by MDCT both for the total aortic valve and separately for each leaflet. 34 patients had LFLGAS and 103 non-LFLGAS. Total aortic valve calcification volume (p < 0.001), mass (p < 0.001), and density (p = 0.004) were lower in LFLGAS as compared to non-LFLGAS patients. At 30-day follow-up, mean transaortic pressure gradients and more than mild paravalvular regurgitation did not differ between groups. In conclusion, LFLGAS and non-LFLGAS express different calcification patterns which, however, did not impact on device success after TAVR. PMID:26435875

  12. Ferumoxytol MRA for transcatheter aortic valve replacement planning with renal insufficiency.

    PubMed

    Kallianos, Kimberly; Henry, Travis S; Yeghiazarians, Yerem; Zimmet, Jeffrey; Shunk, Kendrick A; Tseng, Elaine E; Mahadevan, Vaikom; Hope, Michael D

    2017-03-15

    Computed tomography angiography (CTA) is the test of choice for pre-procedure imaging of transcatheter aortic valve replacement (TAVR) candidates. The iodinated contrast required, however, increases the risk of renal dysfunction in patients with pre-existing renal failure. Ferumoxytol is a magnetic resonance imaging (MRI) contrast agent that can be used with renal failure. Its long vascular resonance time allows gated MRA sequences that approach CTA in image quality. We present respiratory and cardiac gated MRA enabled by ferumoxytol that can be post-processed in an analogous fashion to CTA. Seven patients with renal failure presenting for TAVR were imaged with respiratory and cardiac gated MRA at 3T using ferumoxtyol for contrast. Aortic annulus, root and peripheral access dimensions were calculated in a fashion identical to that used for CTA. Of these, 6 patients underwent a TAVR procedure and 5 had intraoperative valve assessment with transesophageal echocardiograph (TEE) using standard clinical protocols that employed both two- and three-dimensional techniques. Good correlation between MRA aortic annulus measurements and those from TEE were shown in 5 patients with mean annulus area of 392.4mm 2 (290-470 range) versus 374.1mm 2 (285-440 range), with a pairwise correlation coefficient of 0.92, p=0.029. All patients received Sapien valve implants (one 20mm, three 23mm, and two 26mm valves). Access decisions were guided by MRA with no complications. Annulus sizing resulted in no greater than trace/mild aortic regurgitation in all patients. Ferumoxytol MRA is a safe alternative to CTA in patients with renal failure for pre-TAVR analysis of the aortic root and peripheral access. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Computed Tomography Helps to Plan Minimally Invasive Aortic Valve Replacement Operations.

    PubMed

    Stoliński, Jarosław; Plicner, Dariusz; Grudzień, Grzegorz; Kruszec, Paweł; Fijorek, Kamil; Musiał, Robert; Andres, Janusz

    2016-05-01

    This study evaluated the role of multidetector computed tomography (MDCT) in preparation for minimally invasive aortic valve replacement (MIAVR). An analysis of 187 patients scheduled for MIAVR between June 2009 and December 2014 was conducted. In the study group (n = 86), MDCT of the thorax, aorta, and femoral arteries was performed before the operation. In the control group (n = 101), patients qualified for MIAVR without receiving preoperative MDCT. The surgical strategy was changed preoperatively in 12.8% of patients from the study group and in 2.0% of patients from the control group (p = 0.010) and intraoperatively in 9.9% of patients from the control group and in none from the study group (p = 0.002). No conversion to median sternotomy was necessary in the study group; among the controls, there were 4.0% conversions. On the basis of the MDCT measurements, optimal access to the aortic valve was achieved when the angle between the aortic valve plane and the line to the second intercostal space was 91.9 ± 10.0 degrees and to the third intercostal space was 94.0 ± 1.4 degrees, with the distance to the valve being 94.8 ± 13.8 mm and 84.5 ± 9.9 mm for the second and third intercostal spaces, respectively. The right atrium covering the site of the aortotomy was present in 42.9% of cases when MIAVR had been performed through the third intercostal space and in 1.3% when through the second intercostal space (p = 0.001). Preoperative MDCT of the thorax, aorta, and femoral arteries makes it possible to plan MIAVR operations. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Aortic valve repair leads to a low incidence of valve-related complications.

    PubMed

    Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim

    2010-01-01

    Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  15. Left ventricular mass regression after aortic valve replacement with the new Mitroflow 12A pericardial bioprosthesis.

    PubMed

    García-Bengochea, José; Sierra, Juan; González-Juanatey, José R; Rubio, José; Vega, Marino; Fernández, Angel L; Sánchez, Daniel

    2006-05-01

    The study aim was to evaluate the durability of the new Mitroflow 12A pericardial bioprosthesis and to assess ventricular mass regression after aortic valve replacement (AVR) in patients with small valves. A total of 326 Mitroflow 12A pericardial bioprostheses was implanted without any other associated valve procedure. The mean patient age was 73.5 +/- 6.1 years; 252 patients (78.0%) were in NYHA class III/IV. Small valves (19 and 21 mm) were implanted in 212 patients (65.6%). The total follow up period was 837.1 patient-years (pt-yr). A subset of 61 patients with preoperative stenosis was selected and submitted to conventional echo-Doppler assessment at a mean period of 11.1 months after surgery. Hospital mortality was 8.6%. At eight years of follow up, survival was 57.1%. Freedom from structural valve deterioration (SVD) was 86.5% per pt-yr. Mean gradients were significantly reduced postoperatively for each valve size (to 18 +/- 8 mmHg for 19-mm valves and 12 +/- 4 mmHg for 25-mm valves). The effective orifice area (EOA) was also increased significantly for all valve sizes (to 1.1 +/- 0.1 cm2 for 19-mm valves and 1.8 +/- 0.2 cm2 for 25-mm valves). The left ventricular mass index (LVMI) decreased significantly, from 177 +/- 29 to 136 +/- 22 g/m2 for the 19-mm valve, and from 200 +/- 42 to 132 +/- 22 g/m2 for the 25-mm valve. The EOA index (EOAI) showed mismatch for the 19- and 21-mm valves (0.74 and 0.82 cm2/m2, respectively). The diagrammatic calculation between LVMI and relative wall thickness after surgery showed that 29.7% of patients achieved a normal pattern of remodeling (including 19- and 21-mm valves), despite various degrees of mismatch. The new Mitroflow 12A pericardial bioprosthesis showed an absence of mechanical failure after an eight-year follow up, with a satisfactory rate of SVD. Significant reductions in LVMI and improved ventricular geometry were observed, despite the small valve sizes implanted.

  16. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    PubMed

    O' Sullivan, Katie E; Casserly, Ivan; Hurley, John

    2015-04-01

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  17. Latest evidence on transcatheter aortic valve implantation vs. surgical aortic valve replacement for the treatment of aortic stenosis in high and intermediate-risk patients.

    PubMed

    Praz, Fabien; Siontis, George C M; Verma, Subodh; Windecker, Stephan; Jüni, Peter

    2017-03-01

    The goal of this review is to summarize the current evidence supporting the use of transcatheter aortic valve implantation (TAVI) in high and intermediate-risk patients. The focus is on the five randomized controlled trials comparing TAVI with surgical aortic valve replacement (SAVR) published to date, as well as two recent meta-analyses. TAVI has profoundly transformed the treatment of elderly patients presenting with symptomatic severe aortic stenosis. In experienced hands, the procedure has become well tolerated and the results more predictable. So far, two trials using two different devices [Placement of Aortic Transcatheter Valve (PARTNER) 1A and US CoreValve High Risk] have shown that TAVI is able to compete in terms of mortality with SAVR in high-risk patients. These findings have been extended to the intermediate-risk population in two recently published randomized controlled trials [PARTNER 2 and Nordic Aortic Valve Intervention (NOTION)]. The two meta-analyses suggested improved survival in both high and intermediate-risk patients during the first 2 years following the intervention. The survival benefit was only found in patients treated via the transfemoral access, and appeared more pronounced in women. Individual randomized trials enrolling high and intermediate-risk patients have established the noninferiority of TAVI in comparison with SAVR, whereas subsequent meta-analyses suggest superiority of transfemoral TAVI in terms of a sustained survival benefit 2 years after valve implantation irrespective of the surgical risk category. The benefit of TAVI appears more pronounced in women than in men.

  18. 3D Printed Cardiac Phantom for Procedural Planning of a Transcatheter Native Mitral Valve Replacement

    PubMed Central

    Izzo, Richard L.; O’Hara, Ryan P.; Iyer, Vijay; Hansen, Rose; Meess, Karen M.; Nagesh, S.V. Setlur; Rudin, Stephen; Siddiqui, Adnan H.; Springer, Michael; Ionita, Ciprian N.

    2017-01-01

    3D printing an anatomically accurate, functional flow loop phantom of a patient’s cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient’s cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. Results After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone. PMID:28615797

  19. 3D Printed Cardiac Phantom for Procedural Planning of a Transcatheter Native Mitral Valve Replacement.

    PubMed

    Izzo, Richard L; O'Hara, Ryan P; Iyer, Vijay; Hansen, Rose; Meess, Karen M; Nagesh, S V Setlur; Rudin, Stephen; Siddiqui, Adnan H; Springer, Michael; Ionita, Ciprian N

    2016-02-27

    3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis C-arm bi-Plane angiography system. After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. With advances in image processing and 3D printing technology, it is possible to create realistic patient-specific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.

  20. 3D printed cardiac phantom for procedural planning of a transcatheter native mitral valve replacement

    NASA Astrophysics Data System (ADS)

    Izzo, Richard L.; O'Hara, Ryan P.; Iyer, Vijay; Hansen, Rose; Meess, Karen M.; Nagesh, S. V. Setlur; Rudin, Stephen; Siddiqui, Adnan H.; Springer, Michael; Ionita, Ciprian N.

    2016-03-01

    3D printing an anatomically accurate, functional flow loop phantom of a patient's cardiac vasculature was used to assist in the surgical planning of one of the first native transcatheter mitral valve replacement (TMVR) procedures. CTA scans were acquired from a patient about to undergo the first minimally-invasive native TMVR procedure at the Gates Vascular Institute in Buffalo, NY. A python scripting library, the Vascular Modeling Toolkit (VMTK), was used to segment the 3D geometry of the patient's cardiac chambers and mitral valve with severe stenosis, calcific in nature. A stereolithographic (STL) mesh was generated and AutoDesk Meshmixer was used to transform the vascular surface into a functioning closed flow loop. A Stratasys Objet 500 Connex3 multi-material printer was used to fabricate the phantom with distinguishable material features of the vasculature and calcified valve. The interventional team performed a mock procedure on the phantom, embedding valve cages in the model and imaging the phantom with a Toshiba Infinix INFX-8000V 5-axis Carm bi-Plane angiography system. Results: After performing the mock-procedure on the cardiac phantom, the cardiologists optimized their transapical surgical approach. The mitral valve stenosis and calcification were clearly visible. The phantom was used to inform the sizing of the valve to be implanted. Conclusion: With advances in image processing and 3D printing technology, it is possible to create realistic patientspecific phantoms which can act as a guide for the interventional team. Using 3D printed phantoms as a valve sizing method shows potential as a more informative technique than typical CTA reconstruction alone.

  1. Mitral valve replacement complicated by iatrogenic left ventricular outflow obstruction and paravalvular leak: case report and review of literature.

    PubMed

    Lee, Justin Z; Tey, Kai R; Mizyed, Ahmad; Hennemeyer, Charles T; Janardhanan, Rajesh; Lotun, Kapildeo

    2015-10-09

    Left ventricular outflow tract (LVOT) obstruction and paravalvular leak (PVL) are relatively uncommon, but are serious complications of prosthetic valve replacement. We present a case that displays the unique therapeutic challenges of treating a patient who developed both LVOT obstruction and mitral PVL after undergoing surgical aortic and mitral valve replacement (MVR). We also describe the use of alcohol septal ablation and albumin-glutaraldehyde (BioGlue) for septal ablation to percutaneously treat the patient's LVOT obstruction, followed by use of an Amplatzer vascular plug for percutaneous closure of an antero-medial mitral PVL associated with severe regurgitation. Percutaneous interventional management of these entities may be considered as an initial therapeutic option, especially in high-risk patients with significant morbidity and mortality of repeat surgical operations.

  2. Gait Speed Predicts 30-Day Mortality After Transcatheter Aortic Valve Replacement: Results From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

    PubMed

    Alfredsson, Joakim; Stebbins, Amanda; Brennan, J Matthew; Matsouaka, Roland; Afilalo, Jonathan; Peterson, Eric D; Vemulapalli, Sreekanth; Rumsfeld, John S; Shahian, David; Mack, Michael J; Alexander, Karen P

    2016-04-05

    Surgical risk scores do not include frailty assessments (eg, gait speed), which are of particular importance for patients with severe aortic stenosis considering transcatheter aortic valve replacement. We assessed the association of 5-m gait speed with outcomes in a cohort of 8039 patients who underwent transcatheter aortic valve replacement (November 2011-June 2014) and were included in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. We evaluated the association between continuous and categorical gait speed and 30-day all-cause mortality before and after adjustment for Society of Thoracic Surgeons-predicted risk of mortality score and key variables. Secondary outcomes included in-hospital mortality, bleeding, acute kidney injury, and stroke. The overall median gait speed was 0.63 m/s (25th-75th percentile, 0.47-0.79 m/s), with the slowest walkers (<0.5 m/s) constituting 28%, slow walkers (0.5-0.83 m/s) making up 48%, and normal walkers (>0.83 m/s) constituting 24% of the population. Thirty-day all-cause mortality rates were 8.4%, 6.6%, and 5.4% for the slowest, slow, and normal walkers, respectively (P<0.001). Each 0.2-m/s decrease in gait speed corresponded to an 11% increase in 30-day mortality (adjusted odds ratio, 1.11; 95% confidence interval, 1.01-1.22). The slowest walkers had 35% higher 30-day mortality than normal walkers (adjusted odds ratio, 1.35; 95% confidence interval, 1.01-1.80), significantly longer hospital stays, and a lower probability of being discharged to home. Gait speed is independently associated with 30-day mortality after transcatheter aortic valve replacement. Identification of frail patients with the slowest gait speeds facilitates preprocedural evaluation and anticipation of a higher level of postprocedural care. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01737528. © 2016 American Heart Association, Inc.

  3. Intermediate results of isolated mitral valve replacement with a Biocor porcine valve.

    PubMed

    Rizzoli, Giulio; Bottio, Tomaso; Vida, Vladimiro; Nesseris, Georgios; Caprili, Luca; Thiene, Gaetano; Gerosa, Gino

    2005-02-01

    We analyzed the intermediate experience, survival, and prosthetic complications of patients who received the Biocor valve, a new-generation porcine valve, in the mitral position. At the University of Padua, between May 1992 and January 2004, 154 consecutive patients (102 female and 52 male patients; mean age, 72.3 +/- 6 years; age range, 37-86 years) received 158 mitral Biocor prostheses (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil). Thirty-five percent of the patients had previous mitral operations, 24% had coronary artery bypass grafting, and 34.6% had other procedures. Median preoperative New York Heart Association class was III. Echocardiography was performed in 75% of the long-term survivors. Follow-up included 609.4 patient-years and was 100% complete, with a median time of 4 patient-years (range, 0.02-11.3 years). At 8 years, 20 (14%) of 142 operative survivors were still at risk. Early mortality was 13.6%. According to univariate analysis, New York Heart Association class III to IV, ejection fraction of less than 40%, urgency, male sex, and coronary artery bypass grafting were significant perioperative risk factors. Eight- and 10-year actuarial survival was 51.1% +/- 5.6% (40 deaths). Eight-year actuarial freedom from valve-related death, thromboembolism, anticoagulant-related hemorrhage, endocarditis, paravalvular leak, and valve-related complications were 85.2% +/- 5%, 85.7% +/- 4.4%, 92.6% +/- 3.7%, 94.1% +/- 3%, 91.8% +/- 3%, and 70.2% +/- 5.7%, respectively. Freedom from structural valve deterioration was 100%. Actual freedom from reoperation was 93.2% +/- 2.2%. By Doppler echocardiography, the peak and mean transprosthetic gradients were 15 +/- 5 mm Hg and 6.3 +/- 3 mm Hg, respectively (mean follow-up, 4.2 +/- 2.7 years). At intermediate follow-up, the Biocor prosthesis in the mitral position showed excellent results in terms of valve durability when compared with other second-generation tissue valves.

  4. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    PubMed

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (<4%) inter-modality nonsignificant biases. Repeated measurements showed <10% measurements variability. The new 3D analysis was the more accurate and reproducible of the existing echocardiographic techniques. Novel semi-automated 3DTEE analysis software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  5. Quality of life in high-risk patients: comparison of transcatheter aortic valve implantation with surgical aortic valve replacement.

    PubMed

    Amonn, Kathrin; Stortecky, Stefan; Brinks, Henriette; Gahl, Brigitta; Windecker, Stephan; Wenaweser, Peter; Carrel, Thierry; Huber, Christoph

    2013-01-01

    To compare health-related quality of life (QoL) in patients undergoing transcatheter aortic valve implantation via transapical access (TA TAVI) with patients undergoing surgical aortic valve replacement (SAVR). One hundred and forty-four high-risk patients referred for aortic valve replacement underwent TAVI screening and were assigned to either TA TAVI (n = 51, age 79.7 ± 9.2 years, logistic EuroSCORE 26.5 ± 16.1%, 51% males) or SAVR (n = 93, age 81.1 ± 5.3 years, logistic EuroSCORE 12.1 ± 9.3%, 42% males) by the interdisciplinary heart team. QoL was assessed using the Short Form 36 (SF-36) Health Survey Questionnaire and the Hospital Anxiety and Depression Scale. Furthermore, current living conditions and the degree of independence at home were evaluated. Patients undergoing TA TAVI were at higher risk as assessed by EuroSCORE (26.5 ± 16 vs. 12.1 ± 9, P < 0.001) and STS score (6.7 ± 4 vs. 4.4 ± 3, P < 0.001) compared with SAVR patients. At the 30-day follow-up, the rate of mortality was similar and amounted to 7.8% for TA TAVI and 7.5% for SAVR patients and raised to 25.5% in TA TAVI and 18.3% in SAVR patients after a follow-up period of 15 ± 10 months. Assessment of QoL revealed no differences in terms of anxiety and depression between TA TAVI and SAVR patients. The SF-36 mental health metascore was similar in both groups (65.6 ± 19 vs. 68.8 ± 22, P = 0.29), while a significant difference was observed in the physical health metascore (49.7 ± 21 vs. 62.0 ± 21, P = 0.015). After adjustment for baseline characteristics, this difference disappeared. However, every added point in the preoperative risk assessment with the STS score decreased the SF-36 physical health dimension by two raw points at the follow-up assessment. Selected high-risk patients undergoing TAVI by using a transapical access achieve similar clinical outcomes and QoL compared with patients undergoing SAVR. Increased STS scores predict worse QoL outcomes.

  6. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    ClinicalTrials.gov

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  7. Preservation of the bicuspid aortic valve.

    PubMed

    Schäfers, Hans-Joachim; Aicher, Diana; Langer, Frank; Lausberg, Henning F

    2007-02-01

    Bicuspid anatomy of the aortic valve is a common reason for aortic regurgitation and is associated with aortic dilatation in more than 50% of patients. We have observed different patterns of aortic dilatation and used different approaches preserving the valve. Between October 1995 and February 2006, a regurgitant bicuspid valve was repaired in 173 patients. The aorta was normal in 57 patients who underwent isolated repair. Aortic dilatation mainly above commissural level (n = 38) was treated by separate valve repair plus supracommissural aortic replacement. In 78 patients, aortic dilatation involved the root and was treated by root remodeling. Hospital mortality and perioperative morbidity were low in all three groups. Myocardial ischemia was significantly shorter in repair plus aortic replacement than remodeling (p < 0.001). Freedom from aortic regurgitation II or greater at 5 years varied between 91% and 96%. Freedom from reoperation at 5 years was 97% after remodeling, but only 53% after repair plus aortic replacement (p = 0.33). Symmetric prolapse was the most frequent cause for reoperation. The long-term stability of bicuspid aortic valve repair is excellent in the absence of aortic pathology. In the presence of aortic dilatation, root remodeling leads to equally stable valve durability. In patients with less pronounced root dilatation, separate valve repair plus aortic replacement may be a less complex alternative. Symmetric prolapse should be avoided if the ascending aorta is replaced.

  8. Streptococcus pneumoniae endocarditis on replacement aortic valve with panopthalmitis and pseudoabscess

    PubMed Central

    O’Brien, Stephen; Dayer, Mark; Benzimra, James; Hardman, Susan; Townsend, Mandie

    2011-01-01

    A 63-year-old woman with a previous episode of Streptococcus agalactiae endocarditis requiring a bioprosthetic aortic valve replacement presented with a short history of malaise, a right panopthalmitis with a Roth spot on funduscopy of the left eye and Streptococcus pneumoniae grown from vitreous and aqueous taps as well as blood cultures. She developed first degree heart block and her ECG was suggestive of an aortic root abscess. This gradually resolved over 6 weeks, during which she was treated with intravenous antibiotics. After careful consideration, it is likely that what was thought to be an aortic root abscess was instead an area of perivalvular inflammation. PMID:22678733

  9. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    PubMed

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  10. Quality of Life After Transcatheter Aortic Valve Replacement: Prospective Data From GARY (German Aortic Valve Registry).

    PubMed

    Lange, Rüdiger; Beckmann, Andreas; Neumann, Till; Krane, Markus; Deutsch, Marcus-André; Landwehr, Sandra; Kötting, Joachim; Welz, Armin; Zahn, Ralf; Cremer, Jochen; Figulla, Hans R; Schuler, Gerhard; Holzhey, David M; Funkat, Anne-Kathrin; Heusch, Gerd; Sack, Stefan; Pasic, Miralem; Meinertz, Thomas; Walther, Thomas; Kuck, Karl-Heinz; Beyersdorf, Friedhelm; Böhm, Michael; Möllmann, Helge; Hamm, Christian W; Mohr, Friedrich W

    2016-12-26

    This study sought to analyze health-related quality-of-life (HrQoL) outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) based on data from GARY (German Aortic Valve Registry). Typically, patients currently referred for and treated by TAVR are elderly with a concomitant variable spectrum of multiple comorbidities, disabilities, and limited life expectancy. Beyond mortality and morbidity, the assessment of HrQoL is of paramount importance not only to guide patient-centered clinical decision-making but also to judge this new treatment modality in this high-risk patient population. In 2011, 3,875 patients undergoing TAVR were included in the GARY registry. HrQoL was prospectively measured using the EuroQol 5 dimensions questionnaire self-complete version on paper at baseline and 1 year. Complete follow-up EuroQol 5 dimensions questionnaire evaluation was available for 2,288 patients (transvascular transcatheter aortic valve replacement [TAVR-TV]: n = 1,626 and transapical TAVR [TAVR-TA]: n = 662). In-hospital mortality was 5.9% (n = 229) and the 1-year mortality was 23% (n = 893). The baseline visual analog scale score for general health status was 52.6% for TAVR-TV and 55.8% for TAVR-TA and, in parallel to an improvement in New York Heart Association functional class, improved to 59.6% and 58.5% at 1 year, respectively (p < 0.001). Between baseline and 1 year, the number of patients reporting no complaints increased by 7.8% (TAVR-TV) and by 3.5% within the mobility dimension, and by 14.1% (TAVR-TV) and 9.2% within the usual activity dimension, whereas only moderate changes were found for the self-care, pain or discomfort, and anxiety or depression dimensions. In a multiple linear regression analysis several pre- and post-operative factors were predictive for less pronounced HrQoL benefits. TAVR treatment led to improvements in HrQoL, especially in terms of mobility and usual activities. The magnitude of improvements was higher in the

  11. Practical considerations for optimizing cardiac computed tomography protocols for comprehensive acquisition prior to transcatheter aortic valve replacement.

    PubMed

    Khalique, Omar K; Pulerwitz, Todd C; Halliburton, Sandra S; Kodali, Susheel K; Hahn, Rebecca T; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Leon, Martin B; D'Souza, Belinda; Einstein, Andrew J

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is performed frequently in patients with severe, symptomatic aortic stenosis who are at high risk or inoperable for open surgical aortic valve replacement. Computed tomography angiography (CTA) has become the gold standard imaging modality for pre-TAVR cardiac anatomic and vascular access assessment. Traditionally, cardiac CTA has been most frequently used for assessment of coronary artery stenosis, and scanning protocols have generally been tailored for this purpose. Pre-TAVR CTA has different goals than coronary CTA and the high prevalence of chronic kidney disease in the TAVR patient population creates a particular need to optimize protocols for a reduction in iodinated contrast volume. This document reviews details which allow the physician to tailor CTA examinations to maximize image quality and minimize harm, while factoring in multiple patient and scanner variables which must be considered in customizing a pre-TAVR protocol. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  12. Fluid mechanics of heart valves.

    PubMed

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  13. Ross procedure for ascending aortic replacement.

    PubMed

    Elkins, R C; Lane, M M; McCue, C

    1999-06-01

    Patients with aortic valve disease and aneurysm or dilatation of the ascending aorta require both aortic valve replacement and treatment of their ascending aortic disease. In children and young adults, the Ross operation is preferred when the aortic valve requires replacement, but the efficacy of extending this operation to include replacement of the ascending aorta or reduction of the dilated aorta has not been tested. We reviewed the medical records of 18 (5.9%) patients with aortic valve disease and an ascending aortic aneurysm and 26 (8.5%) patients with dilation of the ascending aorta, subgroups of 307 patients who had a Ross operation between August 1986 and February 1998. We examined operative and midterm results, including recent echocardiographic assessment of autograft valve function and ability of the autograft root and ascending aortic repair or replacement to maintain normal structural integrity. There was one operative death (2%) related to a perioperative stroke. Forty-two of 43 survivors have normal autograft valve function, with trace to mild autograft valve insufficiency, and one patient has moderate insufficiency at the most recent echocardiographic evaluation. None of the patients has dilatation of the autograft root or of the replaced or reduced ascending aorta. Early results with extension of the Ross operation to include replacement of an ascending aortic aneurysm or vertical aortoplasty for reduction of a dilated ascending aorta are excellent, with autograft valve function equal to that seen in similar patients without ascending aortic disease.

  14. [Deformation of the tricuspid annulus by pericardial adhesions: a rare cause of early tricuspid regurgitation after mitral valve replacement].

    PubMed

    Tapia, M; Latrémouille, C; Chabert, J P; Fabiani, J N

    1995-12-01

    The authors report the case of major tricuspid regurgitation occurring early after mitral valve replacement. The mechanism was demonstrated at reoperation: the heart was deformed by a posterior pericardial effusion and cardiodiaphragmatic pericardial adhesions.

  15. Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

    PubMed

    El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A

    2018-01-23

    Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.

  16. Patient-prosthesis mismatch in aortic valve replacement: really tolerable?

    PubMed

    Fuster, Rafael García; Montero Argudo, José A; Albarova, Oscar Gil; Sos, Fernando Hornero; López, Sergio Cánovas; Codoñer, María Bueno; Buendía Miñano, José A; Albarran, Ignacio Rodríguez

    2005-03-01

    Several studies have demonstrated favorable results despite patient-prosthesis mismatch after aortic valve replacement with the use of third generation prostheses. Our aim was to determine whether this mismatch is always tolerable. A clinical-echocardiographic study has been performed in 339 consecutive patients who underwent aortic valve replacement because of aortic stenosis. In-hospital outcome and left ventricular mass index regression (1st month-1st year) were analyzed in the presence or absence of mismatch (indexed effective orifice area < or =0.85cm(2)/m(2)). The influence of high degrees of preoperative left ventricular mass on in-hospital mortality has also been evaluated. Left ventricular mass index was considered increased if the calculated value was over the superior quartile of the frequency distribution of all the values observed in both sexes. Mismatch was found in 38% of the patients. In the absence of mismatch, the absolute mass regression was proportional to the preoperative left ventricular mass. This regression was higher in patients with increased left ventricular mass indexed (vs not increased): -38.0+/-7.8 vs -8.8+/-4.7g/m(2), p<0.01 (1st month) and -67.7+/-16.9vs -23.5+/-6.7g/m(2), p<0.05 (1st year). Mass regression was impaired in the presence of mismatch, particularly, in patients with previously increased left ventricular mass: -8.2+/-11.6 vs -5.6+/-6.3g/m(2) (p=0.83) and -24.6+/-12.6 vs -11.7+/-10.5g/m(2) (p=0.54). This worse regression was reflected on a 100% incidence of residual hypertrophy at follow-up (1st month-1st year). In the presence of mismatch, increased ventricular mass was associated with higher mortality: 14.7% vs 2.1% (p<0.01). In the absence of mismatch, ventricular mass was not associated with mortality: 4.1 vs 2.5% (p=0.55). In patients with severe ventricular hypertrophy it may be important to elude patient-prosthesis mismatch to avoid a significant increase in mortality and improve ventricular mass regression

  17. Patient selection for transcatheter aortic valve replacement: A combined clinical and multimodality imaging approach

    PubMed Central

    Cocchia, Rosangela; D’Andrea, Antonello; Conte, Marianna; Cavallaro, Massimo; Riegler, Lucia; Citro, Rodolfo; Sirignano, Cesare; Imbriaco, Massimo; Cappelli, Maurizio; Gregorio, Giovanni; Calabrò, Raffaele; Bossone, Eduardo

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional data. Multi-Imaging modalities should be preferred for assessing the anatomy and the dimensions of the aortic valve and annulus before TAVR. Ultrasounds represent the first line tool in evaluation of this patients giving detailed anatomic description of aortic valve complex and allowing estimating with enough reliability the hemodynamic entity of valvular stenosis. Angiography should be used to assess coronary involvement and plan a revascularization strategy before the implant. Multislice computed tomography play a central role as it can give anatomical details in order to choice the best fitting prosthesis, evaluate the morphology of the access path and detect other relevant comorbidities. Cardiovascular magnetic resonance and positron emission tomography are emergent modality helpful in aortic stenosis evaluation. The aim of this review is to give an overview on TAVR clinical and technical aspects essential for adequate selection. PMID:28400918

  18. International normalized ratio self-management lowers the risk of thromboembolic events after prosthetic heart valve replacement.

    PubMed

    Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner

    2008-03-01

    Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p < 0.001). Moreover, INR values of patients with conventional INR management were frequently measured outside the INR target range, whereas those with anticoagulation self-management mostly remained within the range (35% vs 21%, p < 0.001). In addition, the scatter of INR values was smaller if self-managed. Freedom from thromboembolism at 3, 12, and 24 months, respectively, was 99%, 95%, and 91% in group 1 compared with 99%, 98%, and 96% in group 2 (p = 0.008). Bleeding events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.

  19. A poliomyelitis model through mucosal infection in transgenic mice bearing human poliovirus receptor, TgPVR21.

    PubMed

    Nagata, Noriyo; Iwasaki, Takuya; Ami, Yasushi; Sato, Yuko; Hatano, Ikuyoshi; Harashima, Ayako; Suzaki, Yuriko; Yoshii, Takao; Hashikawa, Tsutomu; Sata, Tetsutaro; Horiuchi, Yoshinobu; Koike, Satoshi; Kurata, Takeshi; Nomoto, Akio

    2004-03-30

    Transgenic mice bearing the human poliovirus receptor (TgPVR) are less susceptible to oral inoculation, although they are susceptible to parenteral inoculation. We investigated the susceptibility of TgPVR 21 line [Arch. Virol. 130 (1994) 351] to poliovirus through various mucosal routes. Intranasal inoculation of a neurovirulent Mahoney strain (OM1) caused flaccid paralysis with viral replication in the central nervous system at a dose of 10(6) cell culture infectious dose (CCID50), in contrast, no paralysis following oral or intragastric inoculation of the same dose. Intranasal inoculation of a vaccine strain, Sabin 1, at 10(6) CCID50, resulted in no paralysis. Initial replication of poliovirus in the nasal cavity was confirmed by virus isolation and detection of negative-stranded replicative intermediates by RT-PCR and viral antigens using a high-sensitive immunohistochemistry and genome/transcripts by in situ hybridization. Poliovirus-specific IgG antibodies were elevated in the sera of surviving TgPVR21. This model can be used as a mucosal infection model and for differentiation of neurovirulent and attenuated poliovirus strains.

  20. CardiaMed mechanical valve: mid-term results of a multicenter clinical trial.

    PubMed

    Nazarov, Vladimir M; Zheleznev, Sergey I; Bogachev-Prokophiev, Alexandr V; Afanasyev, Alexandr V; Nemchenko, Eugene V; Jeltovskiy, Yuri V; Lavinyukov, Sergey O

    2014-01-01

    Prosthesis choice is a major concern in valvular surgery. A multicenter clinical trial was performed to assess the efficacy and safety of the CardiaMed prosthetic heart valve. The study enrolled 420 patients who underwent mitral (209) or aortic (211) valve replacement from 2003 to 2004 at 7 institutions in Russia, and who were followed up from 2006 to 2011. The mean age was 52.2 ± 10.2 years (range, 12-78 years), 47.4% were female, and 99.05% completed the study. The maximum observation term was 7.5 years (2188.5 patient-years); 1081.6 patient-years for aortic and 1106.9 patient-years for mitral valve replacement. The overall 7-year survival rate was 85.1%  ± 3.7%; 86.1%  ± 4.8% and 84.4%  ± 5.4% for aortic and mitral valve replacement, respectively. The 7-year freedom from valve-related death was 93.9%  ± 3.7% and 94.5%  ± 3.2% for aortic and mitral valve replacement, respectively. When early mortality (<30 days) was excluded, these rates were 94.8%  ± 3.1% and 93.8%  ± 3.82%, respectively. Linearized valve-dependent complication rates were determined for structural valve failure (0%/patient-year overall), thrombosis (0.63%/patient-year, all for mitral valve replacement), thromboembolic complications including transient neurologic deficits (0.13%/patient-year overall, 0.5%/patient-year for aortic valve replacement, 0.8%/patient-year for mitral valve replacement), hemorrhagic bleeding (0.64%/patient-year overall, 0.55%/patient-year for aortic valve replacement, 0.09%/patient-year for mitral valve replacement), prosthetic endocarditis (0.28%/patient-year overall, 0.28%/patient-year for aortic valve replacement, 0%/patient-year for mitral valve replacement), and hemolysis (0%/patient-year overall). The CardiaMed mechanical heart valve prostheses meets world standards of safety and efficacy.

  1. Indication for percutaneous aortic valve implantation

    PubMed Central

    Akin, Ibrahim; Kische, Stephan; Rehders, Tim C.; Nienaber, Christoph A.; Rauchhaus, Mathias; Schneider, Henrik; Liebold, Andreas

    2010-01-01

    The incidence of valvular aortic stenosis has increased over the past decades due to improved life expectancy. Surgical aortic valve replacement is currently the only treatment option for severe symptomatic aortic stenosis that has been shown to improve survival. However, up to one third of patients who require lifesaving surgical aortic valve replacement are denied surgery due to high comorbidities resulting in a higher operative mortality rate. In the past such patients could only be treated with medical therapy or percutaneous aortic valvuloplasty, neither of which has been shown to improve mortality. With advances in interventional cardiology, transcatheter methods have been developed for aortic valve replacement with the goal of offering a therapeutic solution for patients who are unfit for surgical therapy. Currently there are two catheter-based treatment systems in clinical application (the Edwards SAPIEN aortic valve and the CoreValve ReValving System), utilizing either a balloon-expandable or a self-expanding stent platform, respectively. PMID:22371763

  2. Progression of Tricuspid Regurgitation after Mitral Valve Replacement for Rheumatic Heart Disease.

    PubMed

    Q Tri, Ho H; Vinh, Pham N

    2017-05-01

    Progression of tricuspid regurgitation (TR) may occur after mitral valve replacement (MVR). The study aim was to define the independent predictors for new severe TR after MVR to treat rheumatic heart disease. A total of 413 patients (177 men, 236 women; mean age 40.9 ± 9.2 years) with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair at the authors' institute between 1995 and 2005, who did not have preoperative severe TR, were followed for at least one year postoperatively. Survival without severe TR was estimated using the Kaplan-Meier method. Independent predictors for new severe TR were identified using multiple Cox regression analysis. During a median follow up of 13 years there were two late deaths, and 46 patients (11.1%) had new severe TR. Survival without severe TR was 88.0 ± 1.7% at 10 years. Independent predictors for new severe TR were preoperative moderate TR (HR 2.401; p = 0.008) and atrial fibrillation (AF) (HR 2.119; p = 0.018). At the most recent follow up, furosemide was used in 23.9% patients with and 7.3% patients without new severe TR (p = 0.001). Patients with new severe TR had larger right ventricles and higher pulmonary artery pressures on echocardiography. Among patients with rheumatic heart disease undergoing MVR without concomitant tricuspid valve repair, independent predictors for new severe TR were preoperative moderate TR and AF. New severe TR was associated with increased furosemide use.

  3. Transcatheter Mitral Valve Replacement for Patients With Symptomatic Mitral Regurgitation: A Global Feasibility Trial.

    PubMed

    Muller, David W M; Farivar, Robert Saeid; Jansz, Paul; Bae, Richard; Walters, Darren; Clarke, Andrew; Grayburn, Paul A; Stoler, Robert C; Dahle, Gry; Rein, Kjell A; Shaw, Marty; Scalia, Gregory M; Guerrero, Mayra; Pearson, Paul; Kapadia, Samir; Gillinov, Marc; Pichard, Augusto; Corso, Paul; Popma, Jeffrey; Chuang, Michael; Blanke, Philipp; Leipsic, Jonathon; Sorajja, Paul

    2017-01-31

    Symptomatic mitral regurgitation (MR) is associated with high morbidity and mortality that can be ameliorated by surgical valve repair or replacement. Despite this, many patients with MR do not undergo surgery. Transcatheter mitral valve replacement (TMVR) may be an option for selected patients with severe MR. This study aimed to examine the effectiveness and safety of TMVR in a cohort of patients with native valve MR who were at high risk for cardiac surgery. Patients underwent transcatheter, transapical delivery of a self-expanding mitral valve prosthesis and were examined in a prospective registry for short-term and 30-day outcomes. Thirty patients (age 75.6 ± 9.2 years; 25 men) with grade 3 or 4 MR underwent TMVR. The MR etiology was secondary (n = 23), primary (n = 3), or mixed pathology (n = 4). The Society of Thoracic Surgeons Predicted Risk of Mortality was 7.3 ± 5.7%. Successful device implantation was achieved in 28 patients (93.3%). There were no acute deaths, strokes, or myocardial infarctions. One patient died 13 days after TMVR from hospital-acquired pneumonia. Prosthetic leaflet thrombosis was detected in 1 patient at follow-up and resolved after increased oral anticoagulation with warfarin. At 30 days, transthoracic echocardiography showed mild (1+) central MR in 1 patient, and no residual MR in the remaining 26 patients with valves in situ. The left ventricular end-diastolic volume index decreased (90.1 ± 28.2 ml/m 2 at baseline vs. 72.1 ± 19.3 ml/m 2 at follow-up; p = 0.0012), as did the left ventricular end-systolic volume index (48.4 ± 19.7 ml/m 2 vs. 43.1 ± 16.2 ml/m 2 ; p = 0.18). Seventy-five percent of the patients reported mild or no symptoms at follow-up (New York Heart Association functional class I or II). Successful device implantation free of cardiovascular mortality, stroke, and device malfunction at 30 days was 86.6%. TMVR is an effective and safe therapy for selected patients with symptomatic native MR. Further

  4. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    PubMed

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. The effect of X-ray beam distortion on the Edwards Sapien XT(™) trans-catheter aortic valve replacement prosthesis.

    PubMed

    Crowhurst, James A; Poon, Karl K; Murdoch, Dale; Incani, Alexander; Raffel, Owen C; Liddicoat, Annelise; Walters, Darren

    2015-12-01

    Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C-arm rotation that were required to bring the valve back to a coaxial appearance was recorded. When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C-arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth.

  6. The challenge of valve-in-valve procedures in degenerated Mitroflow bioprostheses and the advantage of using the JenaValve transcatheter heart valve.

    PubMed

    Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik

    2014-12-01

    Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.

  7. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    PubMed

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  8. Clinical efficacy of transcatheter aortic valve replacement for severe aortic stenosis in high-risk patients: the PREVAIL JAPAN trial.

    PubMed

    Sawa, Yoshiki; Takayama, Morimasa; Mitsudo, Kazuaki; Nanto, Shinsuke; Takanashi, Shuichiro; Komiya, Tatsuhiko; Kuratani, Toru; Tobaru, Tetsuya; Goto, Tsuyoshi

    2015-01-01

    Transcatheter aortic valve replacement (TAVR) is suggested to be less invasive and/or equally effective in comparison to conventional aortic valve replacement for high-risk symptomatic aortic stenosis patients. We herein report the initial results of a pivotal clinical trial of TAVR in Japan (the PREVAIL JAPAN). Sixty-four aortic stenosis patients (mean age 84.3 ± 6.1 years) not suitable for surgery were enrolled at three centers in Japan, with a primary composite endpoint of the 6-month post-procedure improvements in the aortic valve area and New York Heart Association (NYHA) functional classification. A transfemoral approach was used in 37 patients and a transapical approach was used in 27. The device success rate was 91.9 %. After 30 days and 6 months, the rates of mortality from any cause were 8.1 and 11.3 %, respectively. At 6 months, symptomatic stroke was found in 3.1 % of the patients, and silent infarction in 7.8 %. The aortic valve area and mean pressure gradient were significantly improved over time with both approaches (p < 0.001). At 6 months, the NYHA functional classification based on a conventional physician's assessment was improved in 87.9 % of the patients. We found results that were equivalent to those in other major TAVR trials, such as an acceptable 30-day survival (91.9 %), suggesting that balloon-expandable TAVR is effective for small Japanese AS patients classified as high-risk or inoperable.

  9. Failing stentless Bioprostheses in patients with carcinoid heart valve disease.

    PubMed

    Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut

    2015-03-27

    Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.

  10. Quality of Life and Anxiety in Younger Patients after Biological versus Mechanical Aortic Valve Replacement.

    PubMed

    Kottmaier, Marc; Hettich, Ina; Deutsch, Marcus-André; Badiu, Catalin; Krane, Markus; Lange, Ruediger; Bleiziffer, Sabine

    2017-04-01

    Background  Since biological valve recipients are likely to need a redo procedure in the future for valve deterioration, we hypothesized patients might be more fearful about the progression of their disease than patients after aortic valve replacement (AVR) with a mechanical valve. The aim of this study is to compare the quality of life (QOL) and anxiety in patients who have undergone biological versus mechanical AVR. Method  A total of 56 patients after mechanical AVR (mean age: 64.4 ± 8.17 years) and 66 patients after biological AVR (mean age: 64.8 ± 11.05 years) received three questionnaires 5.66 (± 2.68) years after surgery, including: The short form-36 (SF-36) to assess QOL, the fear of progression questionnaire (FOP), and the cardiac anxiety questionnaire (CAQ) to assess general anxiety, anxiety related to cardiac symptoms, and anxiety about progression of heart disease and valve and anticoagulation-specific questions. Results  No significant differences were found for all categories of the SF-36. The FOP showed significantly favorable values for the biological AVR group. The CAQ showed a tendency in the subscale "avoidance" (i.e., avoidance of pulse increase) and "attention" towards more favorable values for the biological AVR group. Conclusions  In contrast to our hypothesis, patients after mechanical AVR show significantly higher anxiety values for the FOP, and a tendency toward higher values for "avoidance" (i.e., avoidance of pulse increase). Partnership concerns, especially in terms of sexuality can be explained by factors that are recognizable for the partner, such as valve sound. These data provide evidence that factors that are continuously present after mechanical AVR, such as valve sound or anticoagulation might affect wellbeing stronger than the certainty of reoperation in the future after biological AVR. We conclude that implantation of a biological prosthesis can be justified in younger patients with regards to QOL. Georg

  11. Use of a Valved-Conduit for Exclusion of the Infected Portion in the Prosthetic Pulmonary Valve Endocarditis

    PubMed Central

    Jung, Joonho; Lee, Cheol Joo; Lim, Sang-Hyun; Choi, Ho; Park, Soo-Jin

    2013-01-01

    A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39℃) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method. PMID:23772409

  12. Haemodynamic outcome at four-dimensional flow magnetic resonance imaging following valve-sparing aortic root replacement with tricuspid and bicuspid valve morphology

    PubMed Central

    Semaan, Edouard; Markl, Michael; Chris Malaisrie, S.; Barker, Alex; Allen, Bradley; McCarthy, Patrick; Carr, James C.; Collins, Jeremy D.

    2014-01-01

    OBJECTIVE To provide a more complete characterization of aortic blood flow in patients following valve-sparing aortic root replacement (VSARR) compared with presurgical cohorts matched by tricuspid and bicuspid valve morphology, age and presurgical aorta size. METHODS Four-dimensional (4D) flow magnetic resonance imaging (MRI) was performed to analyse three-dimensional (3D) blood flow in the thoracic aorta of n = 13 patients after VSARR with reimplantation of native tricuspid aortic valve (TAV, n = 6) and bicuspid aortic valve (BAV, n = 7). Results were compared with presurgical age and aortic size-matched control cohorts with TAV (n = 10) and BAV (n = 10). Pre- and post-surgical aortic flow was evaluated using time-resolved 3D pathlines using a blinded grading system (0–2, 0 = small, 1 = moderate and 2 = prominent) analysing ascending aortic (AAo) helical flow. Systolic flow profile uniformity in the aortic root, proximal and mid-AAo was evaluated using a four-quadrant model. Further analysis in nine analysis planes distributed along the thoracic aorta quantified peak systolic velocity, retrograde fraction and peak systolic flow acceleration. RESULTS Pronounced AAo helical flow in presurgical control subjects (both BAV and TAV: helix grading = 1.8 ± 0.4) was significantly reduced (0.2 ± 0.4, P < 0.001) in cohorts after VSARR independent of aortic valve morphology. Presurgical AAo flow was highly eccentric for BAV patients but more uniform for TAV. VSARR resulted in less eccentric flow profiles. Systolic peak velocities were significantly (P < 0.05) increased in post-root repair BAV patients throughout the aorta (six of nine analysis planes) and to a lesser extent in TAV patients (three of nine analysis planes). BAV reimplantation resulted in significantly increased peak velocities in the proximal AAo compared with root repair with TAV (2.3 ± 0.6 vs 1.6 ± 0.4 m/s, P = 0.017). Post-surgical patients showed a non-significant trend towards higher systolic flow

  13. The utility of trans-catheter aortic valve replacement after commercialization: does the European experience provide a glimpse into the future use of this technology in the United States?

    PubMed

    Linke, Axel; Walther, Thomas; Schuler, Gerhard

    2010-03-01

    Treatment of aortic stenosis remains challenging in older individuals, as their perioperative mortality for open heart surgery is increased due to comorbidities. Transcatheter aortic valve implantation using the CoreValve ReValving System (Medtronic, Minneapolis, USA) and the Edwards SAPIEN transcatheter heart valve (THV; Edwards Lifescience, Irvine, California, USA) represents an alternative to conventional valve replacement in elderly patients that have a high risk for conventional surgery. This article summarizes the evidence-base from recent clinical trials. The early results of these landmark studies suggest that transcatheter aortic valve implantation with either one of the prosthesis is feasible, safe, improves hemodynamics and, therefore, might be an alternative to conventional aortic valve replacement in very high-risk patients. However, all of the available transcatheter heart valves have certain disadvantages, limiting their use in daily clinical practice. The process of decision making, which valve to use and which access route to choose is illustrated in this article through clinical case scenarios. Additionally, the lessons learned thus far from the European perspective and the potential impact on the future use in the US are discussed. Despite of the progress in this field, we are still lacking an optimal transcatheter heart valve. Once it is available, we can take the plunge to compare transcatheter valve implantation with convention surgery in severe aortic stenosis!

  14. Verification of Pharmacogenetics-Based Warfarin Dosing Algorithms in Han-Chinese Patients Undertaking Mechanic Heart Valve Replacement

    PubMed Central

    Zhao, Li; Chen, Chunxia; Li, Bei; Dong, Li; Guo, Yingqiang; Xiao, Xijun; Zhang, Eryong; Qin, Li

    2014-01-01

    Objective To study the performance of pharmacogenetics-based warfarin dosing algorithms in the initial and the stable warfarin treatment phases in a cohort of Han-Chinese patients undertaking mechanic heart valve replacement. Methods We searched PubMed, Chinese National Knowledge Infrastructure and Wanfang databases for selecting pharmacogenetics-based warfarin dosing models. Patients with mechanic heart valve replacement were consecutively recruited between March 2012 and July 2012. The predicted warfarin dose of each patient was calculated and compared with the observed initial and stable warfarin doses. The percentage of patients whose predicted dose fell within 20% of their actual therapeutic dose (percentage within 20%), and the mean absolute error (MAE) were utilized to evaluate the predictive accuracy of all the selected algorithms. Results A total of 8 algorithms including Du, Huang, Miao, Wei, Zhang, Lou, Gage, and International Warfarin Pharmacogenetics Consortium (IWPC) model, were tested in 181 patients. The MAE of the Gage, IWPC and 6 Han-Chinese pharmacogenetics-based warfarin dosing algorithms was less than 0.6 mg/day in accuracy and the percentage within 20% exceeded 45% in all of the selected models in both the initial and the stable treatment stages. When patients were stratified according to the warfarin dose range, all of the equations demonstrated better performance in the ideal-dose range (1.88–4.38 mg/day) than the low-dose range (<1.88 mg/day). Among the 8 algorithms compared, the algorithms of Wei, Huang, and Miao showed a lower MAE and higher percentage within 20% in both the initial and the stable warfarin dose prediction and in the low-dose and the ideal-dose ranges. Conclusions All of the selected pharmacogenetics-based warfarin dosing regimens performed similarly in our cohort. However, the algorithms of Wei, Huang, and Miao showed a better potential for warfarin prediction in the initial and the stable treatment phases in Han

  15. Verification of pharmacogenetics-based warfarin dosing algorithms in Han-Chinese patients undertaking mechanic heart valve replacement.

    PubMed

    Zhao, Li; Chen, Chunxia; Li, Bei; Dong, Li; Guo, Yingqiang; Xiao, Xijun; Zhang, Eryong; Qin, Li

    2014-01-01

    To study the performance of pharmacogenetics-based warfarin dosing algorithms in the initial and the stable warfarin treatment phases in a cohort of Han-Chinese patients undertaking mechanic heart valve replacement. We searched PubMed, Chinese National Knowledge Infrastructure and Wanfang databases for selecting pharmacogenetics-based warfarin dosing models. Patients with mechanic heart valve replacement were consecutively recruited between March 2012 and July 2012. The predicted warfarin dose of each patient was calculated and compared with the observed initial and stable warfarin doses. The percentage of patients whose predicted dose fell within 20% of their actual therapeutic dose (percentage within 20%), and the mean absolute error (MAE) were utilized to evaluate the predictive accuracy of all the selected algorithms. A total of 8 algorithms including Du, Huang, Miao, Wei, Zhang, Lou, Gage, and International Warfarin Pharmacogenetics Consortium (IWPC) model, were tested in 181 patients. The MAE of the Gage, IWPC and 6 Han-Chinese pharmacogenetics-based warfarin dosing algorithms was less than 0.6 mg/day in accuracy and the percentage within 20% exceeded 45% in all of the selected models in both the initial and the stable treatment stages. When patients were stratified according to the warfarin dose range, all of the equations demonstrated better performance in the ideal-dose range (1.88-4.38 mg/day) than the low-dose range (<1.88 mg/day). Among the 8 algorithms compared, the algorithms of Wei, Huang, and Miao showed a lower MAE and higher percentage within 20% in both the initial and the stable warfarin dose prediction and in the low-dose and the ideal-dose ranges. All of the selected pharmacogenetics-based warfarin dosing regimens performed similarly in our cohort. However, the algorithms of Wei, Huang, and Miao showed a better potential for warfarin prediction in the initial and the stable treatment phases in Han-Chinese patients undertaking mechanic heart

  16. Surgery for rheumatic mitral valve disease in sub-saharan African countries: why valve repair is still the best surgical option.

    PubMed

    Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie

    2016-01-01

    Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.

  17. Transcatheter Aortic Valve Replacement in Pure Native Aortic Valve Regurgitation.

    PubMed

    Yoon, Sung-Han; Schmidt, Tobias; Bleiziffer, Sabine; Schofer, Niklas; Fiorina, Claudia; Munoz-Garcia, Antonio J; Yzeiraj, Ermela; Amat-Santos, Ignacio J; Tchetche, Didier; Jung, Christian; Fujita, Buntaro; Mangieri, Antonio; Deutsch, Marcus-Andre; Ubben, Timm; Deuschl, Florian; Kuwata, Shingo; De Biase, Chiara; Williams, Timothy; Dhoble, Abhijeet; Kim, Won-Keun; Ferrari, Enrico; Barbanti, Marco; Vollema, E Mara; Miceli, Antonio; Giannini, Cristina; Attizzani, Guiherme F; Kong, William K F; Gutierrez-Ibanes, Enrique; Jimenez Diaz, Victor Alfonso; Wijeysundera, Harindra C; Kaneko, Hidehiro; Chakravarty, Tarun; Makar, Moody; Sievert, Horst; Hengstenberg, Christian; Prendergast, Bernard D; Vincent, Flavien; Abdel-Wahab, Mohamed; Nombela-Franco, Luis; Silaschi, Miriam; Tarantini, Giuseppe; Butter, Christian; Ensminger, Stephan M; Hildick-Smith, David; Petronio, Anna Sonia; Yin, Wei-Hsian; De Marco, Federico; Testa, Luca; Van Mieghem, Nicolas M; Whisenant, Brian K; Kuck, Karl-Heinz; Colombo, Antonio; Kar, Saibal; Moris, Cesar; Delgado, Victoria; Maisano, Francesco; Nietlispach, Fabian; Mack, Michael J; Schofer, Joachim; Schaefer, Ulrich; Bax, Jeroen J; Frerker, Christian; Latib, Azeem; Makkar, Raj R

    2017-12-05

    Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR). This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR. From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices. A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001). Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR

  18. Right paracardiac mass due to organized pericardial hematoma around retained epicardial pacing wires following aortic valve replacement.

    PubMed

    Kapoor, Aditya; Syal, Sanjiv; Gupta, Nirmal; Gupta, Archana

    2011-07-01

    The use of temporary epicardial pacing wires during cardiac surgery is a routine procedure and has been associated with low morbidity. We describe a rare case of right paracardiac mass due to organized pericardial hematoma with right atrial compression around the epicardial pacing wires left in-situ, presenting three months following aortic valve replacement surgery. The case highlights the fact that such delayed complications can rarely occur around retained epicardial pacing wires following open heart surgery especially in patients on oral anticoagulants. The clinician should be alert to such an occurrence and during follow-up echocardiography always pay attention not only to the valve and ventricular function, but also to the pericardial and extra-pericardial space.

  19. Should high risk patients with concomitant severe aortic stenosis and mitral valve disease undergo double valve surgery in the TAVR era?

    PubMed

    Yu, Pey-Jen; Mattia, Allan; Cassiere, Hugh A; Esposito, Rick; Manetta, Frank; Kohn, Nina; Hartman, Alan R

    2017-12-29

    Significant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The aim of this study is to determine if surgical correction of both aortic and mitral valves in high risk patients with concomitant valvular disease would offer patients better outcomes than TAVR alone. A retrospective analysis of 43 high-risk patients who underwent concomitant surgical aortic valve replacement and mitral valve surgery from 2008 to 2012 was performed. Immediate and long term survival were assessed. There were 43 high-risk patients with severe aortic stenosis undergoing concomitant surgical aortic valve replacement and mitral valve surgery. The average age was 80 ± 6 years old. Nineteen (44%) patients had prior cardiac surgery, 15 (34.9%) patients had chronic obstructive lung disease, and 39 (91%) patients were in congestive heart failure. The mean Society of Thoracic Surgeons Predicted Risk of Mortality for isolated surgical aortic valve replacement for the cohort was 10.1% ± 6.4%. Five patients (11.6%) died during the index admission and/or within thirty days of surgery. Mortality rate was 25% at six months, 35% at 1 year and 45% at 2 years. There was no correlation between individual preoperative risk factors and mortality. High-risk patients with severe aortic stenosis and mitral valve disease undergoing concomitant surgical aortic valve replacement and mitral valve surgery may have similar long term survival as that described for such patients undergoing TAVR. Surgical correction of double valvular disease in this patient population may not confer mortality benefit compared to TAVR alone.

  20. Tricuspid valve replacement: postoperative and long-term results.

    PubMed

    Van Nooten, G J; Caes, F; Taeymans, Y; Van Belleghem, Y; François, K; De Bacquer, D; Deuvaert, F E; Wellens, F; Primo, G

    1995-09-01

    A series of 146 consecutive patients who underwent tricuspid valve replacement at the University Brugmann Hospital between 1967 and 1987 was reviewed. Mean age at operation was 51.4 years (+/- 12.1 years). Different types of prostheses were implanted including porcine and bovine pericardial bioprostheses and older and bileaflet mechanical valves. Most patients were severely disabled by their cardiac disease before operation, with 30.1% in New York Heart Association functional class III and 69.9% in class IV. Operative mortality and hospital mortality rates (30 days) were high (16.4%). Incremental risk factors for hospital death included icterus (p < 0.005), preoperative hepatomegaly (p = 0.012), and New York Heart Association functional class IV (p = 0.013). Multivariate analysis only selected preoperative icterus (p < 0.01) as being independently significantly related to hospital mortality. The hospital survivors were followed up for a median of 94 months. A complete follow-up was available for all patients except two for 30 months or more. At 30 months the only two significant parameters were the type of myocardial protection (p = 0.024) and the year of operation (before 1977 or after [precardioplegia era or after], p = 0.011). There were 70 late deaths during the entire follow-up period. The univariate (log-rank statistics) incremental risk factor for late death was the type of tricuspid prosthesis (Smeloff-Cutter and Kay-Shiley versus St. Jude Medical versus bioprosthesis) (p = 0.04). A trend was observed for the type of operative myocardial protection (normothermia and coronary perfusion) (p = 0.06) and preoperative New York Heart Association functional class IV (p = 0.055). Actuarial survival was 74% at 60 months and 23.4% at 180 months. Cumulative follow-up added up to 1015 patient-years. In a more detailed analysis of the effect on survival of the type of tricuspid prosthesis, a significant difference was observed between the bioprostheses and some older

  1. Right anterior mini-thoracotomy vs. conventional sternotomy for aortic valve replacement: a propensity-matched comparison

    PubMed Central

    Del Giglio, Mauro; Mikus, Elisa; Micari, Antonio; Calvi, Simone; Tripodi, Alberto; Campo, Gianluca; Maietti, Elisa; Castriota, Fausto; Cremonesi, Alberto

    2018-01-01

    Background Right anterior mini-thoracotomy (MIAVR) is a promising technique for aortic valve replacement. We aimed at comparing its outcomes with those obtained in a propensity-matched group of patients undergoing sternotomy at our two high-volume centers. Methods Main clinical and operative data of patients undergoing aortic valve replacement between January 2010 and May 2016 were retrospectively collected. A total of 678 patients were treated with a standard full sternotomy approach, while MIAVR was performed in 502. Propensity score matching identified 363 patients per each group. Results In-hospital mortality was not significantly different between the propensity-matched groups (1.7% in MIAVR patients vs. 2.2% in conventional sternotomy patients; P=0.79). No significant difference in the incidence of major post-operative complications was observed. Post-operative ventilation times (median 7, range 5–12 hours in MIAVR patients vs. median 7, range 5–12 in conventional sternotomy patients; P=0.72) were not significantly different between the two groups. Cardiopulmonary bypass time (61.0±21.0 vs. 65.9±24.7 min in conventional sternotomy group; P<0.01) and aortic cross-clamping time (48.3±16.7 vs. 53.2±19.6 min in full sternotomy group; P<0.01) were shorter in MIAVR group. EuroSCORE (OR 1.52, 95% CI, 1.12–2.06; P<0.01) was found to be the only independent predictor of intra-hospital mortality in the whole propensity-matched population. Conclusions Our experience shows that mini-access isolated aortic valve surgery is a reproducible, safe and effective procedure with similar outcomes and no longer operative times compared to conventional sternotomy. PMID:29707310

  2. Does the disparity in baseline characteristics of patients undergoing transcatheter aortic valve replacement with 23 mm vs. 26 mm valves impact clinical outcome?

    PubMed

    Escárcega, Ricardo O; Magalhaes, Marco A; Baker, Nevin C; Lipinski, Michael J; Minha, Sa'ar; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-01-01

    We sought to identify if baseline characteristic differences in patients who receive a 23 mm vs. 26 mm valve impact clinical outcomes. Transcatheter aortic valve replacement (TAVR) is currently an approved therapy for patients with severe aortic stenosis who are considered inoperable or are at high risk. We retrospectively examined baseline characteristics and outcomes of patients receiving a 23 mm (n = 132) vs. 26 mm valve (n = 81) via the transfemoral approach. Gender (P < 0.01), previous coronary artery bypass surgery (P < 0.01), history of atrial fibrillation (P = 0.04), and mean Society of Thoracic Surgeons (STS) score (P < 0.01) were significantly different between groups. There were no significant differences in the rates of minor/major vascular complications (2.2 vs. 3.7%, P = 0.68 and 13.0 vs. 12.3%, P = 0.89, respectively). Bleeding complications were also comparable (major bleed 2.3 vs. 1%, P >0.99, minor bleed 19.0 vs. 22.0%, P = 0.67 and life threatening bleed 7.0 vs. 5.0%, P = 0.77). In-hospital death (6.0 vs. 5.0%, P >0.99), 30-day all-cause death (7.6 vs. 6.2%, P = 0.69), and all-cause death at 1 year (17.4 vs. 25.9%, P = 0.13) were also similar between groups. Gender, valve size, previous coronary bypass surgery and atrial fibrillation were not independently associated with mortality; however, on multivariate analysis STS score was (HR 1.11; 95% CI 1.02-1.19; P = 0.01). Patients undergoing TAVR with 23 and 26 mm valves have similar clinical outcomes despite significant differences in baseline characteristics. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  3. Transcatheter aortic valve replacement and vascular complications definitions.

    PubMed

    Van Mieghem, Nicolas M; Généreux, Philippe; van der Boon, Robert M A; Kodali, Susheel; Head, Stuart; Williams, Matthew; Daneault, Benoit; Kappetein, Arie-Pieter; de Jaegere, Peter P; Leon, Martin B; Serruys, Patrick W

    2014-03-20

    Transcatheter aortic valve replacement (TAVR) requires large calibre catheters and is therefore associated with increased vascular complications. The aim of this study was to illustrate the impact of the different definitions of major vascular complications on their incidence and to underscore the importance of uniform reporting. We pooled dedicated databases of consecutive patients undergoing TAVR from two tertiary care facilities and looked for the incidence of major vascular complications using various previously reported definitions. The level of agreement (Kappa statistic) between the respective definitions and the Valve Academic Research Consortium (VARC) consensus definition of vascular complications was assessed. A total of 345 consecutive patients underwent transfemoral TAVR and were included in this analysis. A completely percutaneous access and closure technique was applied in 96% of cases. Arterial sheath size ranged between 18 and 24 Fr, the majority being 18 Fr (60%). Procedural success was reached in 94.5%. Depending on the definition used, major vascular complications occurred in 5.2-15.9% of patients. According to the VARC definitions, the rate of major and minor vascular complications was 9.0% and 9.6%, respectively. Major vascular complications according to VARC criteria demonstrated at least a substantial level of agreement with the SOURCE registry (k 0.80), the UK registry (k 0.82) the Italian registry (k 0.72) and "FRANCE" registry (k 0.70) definitions, compared to a moderate level of agreement with the definitions used in the German registry ( 0.47) and the 18 Fr Safety and Efficacy study (k 0.42). Minor complications according to VARC demonstrated a moderate agreement only with vascular complications using the German registry definition (k 0.54). Non-uniformity in how vascular complications are defined precludes any reliable comparison between previously reported TAVR registries. The VARC consensus document offers standardised endpoint

  4. [Percutaneously implantable aortic valve: the JenaValve concept evolution].

    PubMed

    Figulla, Hans R; Ferrari, Markus

    2006-10-01

    Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.

  5. Advanced age and incidence of atrial fibrillation in the postoperative period of aortic valve replacement

    PubMed Central

    Pivatto Júnior, Fernando; Teixeira Filho, Guaracy Fernandes; Sant'anna, João Ricardo Michelin; Py, Pablo Mondim; Prates, Paulo Roberto; Nesralla, Ivo Abrahão; Kalil, Renato Abdala Karam

    2014-01-01

    Objective This study aims to describe the correlation between age and occurrence of atrial fibrillation after aortic stenosis surgery in the elderly as well as evaluate the influence of atrial fibrillation on the incidence of strokes, hospital length of stay, and hospital mortality. Methods Cross-sectional retrospective study of > 70 year-old patients who underwent isolated aortic valve replacement. Results 348 patients were included in the study (mean age 76.8±4.6 years). Overall, post-operative atrial fibrillation was 32.8% (n=114), but it was higher in patients aged 80 years and older (42.9% versus 28.8% in patients aged 70-79 years, P=0.017). There was borderline significance for linear correlation between age and atrial fibrillation (P=0.055). Intensive Care Unit and hospital lengths of stay were significantly increased in atrial fibrillation (P<0.001), but there was no increase in mortality or stroke associated with atrial fibrillation. Conclusion Post-operative atrial fibrillation incidence in aortic valve replacement is high and correlates with age in patients aged 70 years and older and significantly more pronounced in patients aged 80 years. There was increased length of stay at Intensive Care Unit and hospital, but there was no increase in mortality or stroke. These data are important for planning prophylaxis and early treatment for this subgroup. PMID:24896162

  6. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.

    PubMed

    Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K; Goncalves, Alexandra; Di Carli, Marcelo F; Rybicki, Frank J; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron

    2016-01-01

    3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of -0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  7. 3D Printing Based on Cardiac CT Assists Anatomic Visualization Prior to Transcatheter Aortic Valve Replacement

    PubMed Central

    Ripley, Beth; Kelil, Tatiana; Cheezum, Michael K.; Goncalves, Alexandra; Di Carli, Marcelo F.; Rybicki, Frank J.; Steigner, Mike; Mitsouras, Dimitrios; Blankstein, Ron

    2017-01-01

    Background 3D printing is a promising technique that may have applications in medicine, and there is expanding interest in the use of patient-specific 3D models to guide surgical interventions. Objective To determine the feasibility of using cardiac CT to print individual models of the aortic root complex for transcatheter aortic valve replacement (TAVR) planning as well as to determine the ability to predict paravalvular aortic regurgitation (PAR). Methods This retrospective study included 16 patients (9 with PAR identified on blinded interpretation of post-procedure trans-thoracic echocardiography and 7 age, sex, and valve size-matched controls with no PAR). 3D printed models of the aortic root were created from pre-TAVR cardiac computed tomography data. These models were fitted with printed valves and predictions regarding post-implant PAR were made using a light transmission test. Results Aortic root 3D models were highly accurate, with excellent agreement between annulus measurements made on 3D models and those made on corresponding 2D data (mean difference of −0.34 mm, 95% limits of agreement: ± 1.3 mm). The 3D printed valve models were within 0.1 mm of their designed dimensions. Examination of the fit of valves within patient-specific aortic root models correctly predicted PAR in 6 of 9 patients (6 true positive, 3 false negative) and absence of PAR in 5 of 7 patients (5 true negative, 2 false positive). Conclusions Pre-TAVR 3D-printing based on cardiac CT provides a unique patient-specific method to assess the physical interplay of the aortic root and implanted valves. With additional optimization, 3D models may complement traditional techniques used for predicting which patients are more likely to develop PAR. PMID:26732862

  8. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside

    PubMed Central

    Saxon, John T; Allen, Keith B; Cohen, David J

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832

  9. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    PubMed

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  10. Transcatheter aortic valve replacement in patients with severe mitral or tricuspid regurgitation at extreme risk for surgery.

    PubMed

    Little, Stephen H; Popma, Jeffrey J; Kleiman, Neal S; Deeb, G Michael; Gleason, Thomas G; Yakubov, Steven J; Checuti, Stan; O'Hair, Daniel; Bajwa, Tanvir; Mumtaz, Mubashir; Maini, Brijeshwar; Hartman, Alan; Katz, Stanley; Robinson, Newell; Petrossian, George; Heiser, John; Merhi, William; Moore, B Jane; Li, Shuzhen; Adams, David H; Reardon, Michael J

    2018-05-01

    Patients with symptomatic severe aortic stenosis and severe mitral regurgitation or severe tricuspid regurgitation were excluded from the major transcatheter aortic valve replacement trials. We studied these 2 subgroups in patients at extreme risk for surgery in the prospective, nonrandomized, single-arm CoreValve US Expanded Use Study. The primary end point was all-cause mortality or major stroke at 1 year. A favorable medical benefit was defined as a Kansas City Cardiomyopathy Questionnaire overall summary score greater than 45 at 6 months and greater than 60 at 1 year and with a less than 10-point decrease from baseline. There were 53 patients in each group. Baseline characteristics for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were age 84.2 ± 6.4 years and 84.9 ± 6.5 years; male, 29 (54.7%) and 22 (41.5%), and mean Society of Thoracic Surgeons score 9.9% ± 5.0% and 9.2% ± 4.0%, respectively. Improvement in valve regurgitation from baseline to 1 year occurred in 72.7% of the patients with severe mitral regurgitation and in 61.8% of patients with severe tricuspid regurgitation. A favorable medical benefit occurred in 31 of 47 patients (66.0%) with severe mitral regurgitation and 33 of 47 patients (70.2%) with severe tricuspid regurgitation at 6 months, and in 25 of 44 patients (56.8%) with severe mitral regurgitation and 24 of 45 patients (53.3%) with severe tricuspid regurgitation at 1 year. All-cause mortality or major stroke for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were 11.3% and 3.8% at 30 days and 21.0% and 19.2% at 1 year, respectively. There were no major strokes in either group at 1 year. Transcatheter aortic valve replacement in patients with severe mitral regurgitation or severe tricuspid regurgitation is reasonable and safe and leads to improvement in atrioventricular valve regurgitation. Copyright © 2018 The American Association for Thoracic Surgery

  11. Total prosthetic replacement of atrioventricular valves in the dog

    PubMed Central

    Den Otter, G.

    1968-01-01

    The free-floating cone and cage valve, described in a previous study as being successful as a substitute for the right atrioventricular valve, does not perform well when it is inserted in the mitral ostium. A tilting cone or disc was constructed and tested in a series of 15 dogs. This prosthesis gave excellent results in 12 animals. The reasons for its failure in the remaining three is discussed. The prosthesis presented has advantages over any ball and cage valve, mainly because of its smaller volume. Images PMID:5654076

  12. "Bail out" procedures for malpositioning of aortic valve prosthesis (CoreValve).

    PubMed

    Vavouranakis, Manolis; Vrachatis, Dimitrios A; Toutouzas, Konstantinos P; Chrysohoou, Christina; Stefanadis, Christodoulos

    2010-11-05

    Two techniques for correcting malpositioning occurring during percutaneous aortic valve replacement (PAVR) with the CoreValve ReValving™ System are described in this article. The "Removing and Reinserting Technique" was used in 2 patients, in whom the prosthesis was positioned too high. The "Snare Technique" was used in 1 patient, in whom the prosthesis was implanted too low. In all patients the aortic valve prosthesis was successfully re-implanted. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  13. Valve repair in aortic regurgitation without root dilatation--aortic valve repair.

    PubMed

    Lausberg, H F; Aicher, D; Kissinger, A; Langer, F; Fries, R; Schäfers, H-J

    2006-02-01

    Aortic valve repair was established in the context of aortic root remodeling. Variable results have been reported for isolated valve repair. We analyzed our experience with isolated valve repair and compared the results with those of aortic root remodeling. Between October 1995 and August 2003, isolated repair of the aortic valve was performed in 83 patients (REP), remodeling of the aortic valve in 175 patients (REMO). The demographics of the two groups were comparable (REP: mean age 54.4 +/- 20.7 yrs, male-female ratio 2.1 : 1; REMO: mean age 60.8 +/- 13.6 yrs, male-female ratio 2.4 : 1; p = ns). In both groups the number of bicuspid valves was comparable (REP: 41 %, REMO: 32 %; p = ns). All patients were followed by echocardiography for a cumulative follow-up of 8204 patient months (mean 32 +/- 23 months). Overall in-hospital mortality was 2.4 % in REP and 4.6 % in REMO ( p = 0.62). Systolic gradients were comparable in both groups (REP: 5.8 +/- 2.2, REMO: 6.5 +/- 3.1 mm Hg, p = 0.09). The mean degree of aortic regurgitation 12 months postoperatively was 0.8 +/- 0.7 after REP and 0.7 +/- 0.7 after REMO ( p = 0.29). Freedom from significant regurgitation (> or = II degrees ) after 5 years was 86 % in REP and 89 % in REMO ( p = 0.17). Freedom from re-operation after 5 years was 94.4 % in REP and 98.2 % in REMO ( p = 0.33). Aortic regurgitation without concomitant root dilatation can be treated effectively by aortic valve repair. The functional results are equivalent to those obtained with valve-preserving root replacement. Aortic valve repair appears to be an alternative to valve replacement in aortic regurgitation.

  14. Three-dimensional printed trileaflet valve conduits using biological hydrogels and human valve interstitial cells.

    PubMed

    Duan, B; Kapetanovic, E; Hockaday, L A; Butcher, J T

    2014-05-01

    Tissue engineering has great potential to provide a functional de novo living valve replacement, capable of integration with host tissue and growth. Among various valve conduit fabrication techniques, three-dimensional (3-D) bioprinting enables deposition of cells and hydrogels into 3-D constructs with anatomical geometry and heterogeneous mechanical properties. Successful translation of this approach, however, is constrained by the dearth of printable and biocompatible hydrogel materials. Furthermore, it is not known how human valve cells respond to these printed environments. In this study, 3-D printable formulations of hybrid hydrogels are developed, based on methacrylated hyaluronic acid (Me-HA) and methacrylated gelatin (Me-Gel), and used to bioprint heart valve conduits containing encapsulated human aortic valvular interstitial cells (HAVIC). Increasing Me-Gel concentration resulted in lower stiffness and higher viscosity, facilitated cell spreading, and better maintained HAVIC fibroblastic phenotype. Bioprinting accuracy was dependent upon the relative concentrations of Me-Gel and Me-HA, but when optimized enabled the fabrication of a trileaflet valve shape accurate to the original design. HAVIC encapsulated within bioprinted heart valves maintained high viability, and remodeled the initial matrix by depositing collagen and glyosaminoglycans. These findings represent the first rational design of bioprinted trileaflet valve hydrogels that regulate encapsulated human VIC behavior. The use of anatomically accurate living valve scaffolds through bioprinting may accelerate understanding of physiological valve cell interactions and progress towards de novo living valve replacements. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Valve exploiting the principle of a side channel turbine

    NASA Astrophysics Data System (ADS)

    Jandourek, Pavel; Habán, Vladimír; Pochylý, František; Fic, Miloslav

    The article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Reducing valves are a source of hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the valve and the turbine. The basis for the design is the loss characteristics of the valve. Thereby creating a kind of turbine valve with speed-controlled flow in dependence of runner revolution.

  16. Causes of Death Following Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

    PubMed

    Xiong, Tian-Yuan; Liao, Yan-Biao; Zhao, Zhen-Gang; Xu, Yuan-Ning; Wei, Xin; Zuo, Zhi-Liang; Li, Yi-Jian; Cao, Jia-Yu; Tang, Hong; Jilaihawi, Hasan; Feng, Yuan; Chen, Mao

    2015-09-21

    Transcatheter aortic valve replacement (TAVR) is an effective alternative to surgical aortic valve replacement in patients at high surgical risk. However, there is little published literature on the exact causes of death. The PubMed database was systematically searched for studies reporting causes of death within and after 30 days following TAVR. Twenty-eight studies out of 3934 results retrieved were identified. In the overall analysis, 46.4% and 51.6% of deaths were related to noncardiovascular causes within and after the first 30 days, respectively. Within 30 days of TAVR, infection/sepsis (18.5%), heart failure (14.7%), and multiorgan failure (13.2%) were the top 3 causes of death. Beyond 30 days, infection/sepsis (14.3%), heart failure (14.1%), and sudden death (10.8%) were the most common causes. All possible subgroup analyses were made. No significant differences were seen for proportions of cardiovascular deaths except the comparison between moderate (mean STS score 4 to 8) and high (mean STS score >8) -risk patients after 30 days post-TAVR (56.0% versus 33.5%, P=0.005). Cardiovascular and noncardiovascular causes of death are evenly balanced both in the perioperative period and at long-term follow-up after TAVR. Infection/sepsis and heart failure were the most frequent noncardiovascular and cardiovascular causes of death. This study highlights important areas of clinical focus that could further improve outcomes after TAVR. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  17. Long-Term Health Benefit of Transcatheter Aortic Valve Replacement in Patients With Chronic Lung Disease.

    PubMed

    Crestanello, Juan A; Popma, Jeffrey J; Adams, David H; Deeb, G Michael; Mumtaz, Mubashir; George, Barry; Huang, Jian; Reardon, Michael J

    2017-11-27

    This study sought to characterize the long-term effect of chronic lung disease (CLD) on mortality, clinical outcomes, quality of life, and health benefits after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis. The long-term effect of CLD after TAVR is unknown. Prevalence and severity of CLD was determined at baseline in high- and extreme-risk patients with aortic stenosis from the CoreValve US Pivotal Trial. Clinical outcomes and health status were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OS). A favorable health benefit was defined as alive with a KCCQ-OS ≥60 and stability (<10-point decrease) or improvement in the KCCQ-OS from baseline. CLD was present in 55% (20% mild, 13% moderate, 22% severe) of the 1,030 patients studied. All-cause mortality was higher in patients with moderate and severe CLD at 1 year (19.6% mild, 28.1% moderate, 26.9% severe CLD vs. 19.2% non-CLD; p = 0.030) and 3 years (44.8% mild, 53.0% moderate, 51.9% severe vs. 37.7% non-CLD; p < 0.001). New York Heart Association functional class improved in more than 80% of patients with CLD at 1 and 3 years. All patients had a nearly 20-point improvement in KCCQ-OS at 1 and 3 years. However, only 43.3% of patients with CLD had a favorable health benefit at 1 year and 22.5% at 3 years. Moderate and severe CLD increases 1- and 3-year mortality after TAVR. Although functional status and quality of life were improved in CLD at 1 and 3 years after TAVR, a favorable health benefit was only achieved in selected patients. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    PubMed Central

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    SUMMARY 1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird’s-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10–15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage. PMID:19220329

  19. Fluid mechanics of artificial heart valves.

    PubMed

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-02-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mechanical heart valves, these complications are believed to be associated with non-physiological blood flow patterns. 2. In the present review, we provide a bird's-eye view of fluid mechanics for the major artificial heart valve types and highlight how the engineering approach has shaped this rapidly diversifying area of research. 3. Mechanical heart valve designs have evolved significantly, with the most recent designs providing relatively superior haemodynamics with very low aerodynamic resistance. However, high shearing of blood cells and platelets still pose significant design challenges and patients must undergo life-long anticoagulation therapy. Bioprosthetic or tissue valves do not require anticoagulants due to their distinct similarity to the native valve geometry and haemodynamics, but many of these valves fail structurally within the first 10-15 years of implantation. 4. These shortcomings have directed present and future research in three main directions in attempts to design superior artificial valves: (i) engineering living tissue heart valves; (ii) development of advanced computational tools; and (iii) blood experiments to establish the link between flow and blood damage.

  20. Impact of anticoagulation therapy on valve haemodynamic deterioration following transcatheter aortic valve replacement.

    PubMed

    Del Trigo, María; Muñoz-García, Antonio J; Latib, Azeem; Auffret, Vincent; Wijeysundera, Harindra C; Nombela-Franco, Luis; Gutierrez, Enrique; Cheema, Asim N; Serra, Vicenç; Amat-Santos, Ignacio J; Kefer, Joelle; Benitez, Luis Miguel; Leclercq, Florence; Mangieri, Antonio; Le Breton, Hervé; Jiménez-Quevedo, Pilar; Garcia Del Blanco, Bruno; Dager, Antonio; Abdul-Jawad Altisent, Omar; Puri, Rishi; Pibarot, Philippe; Rodés-Cabau, Josep

    2018-05-01

    To evaluate the changes in transvalvular gradients and the incidence of valve haemodynamic deterioration (VHD) following transcatheter aortic valve replacement (TAVR), according to use of anticoagulation therapy. This multicentre study included 2466 patients (46% men; mean age 81±7 years) who underwent TAVR with echocardiography performed at 12-month follow-up. Anticoagulation therapy was used in 707 patients (28.7%) following TAVR (AC group). A total of 663 patients received vitamin K antagonists, and 44 patients received direct oral anticoagulants. A propensity score matching analysis was performed to adjust for intergroup (AC vs non-AC post-TAVR) differences. A total of 622 patients per group were included in the propensity-matched analysis. VHD was defined as a ≥10 mm Hg increase in the mean transprosthetic gradient at follow-up (vs hospital discharge). The mean clinical follow-up was 29±18 months. The mean transvalvular gradient significantly increased at follow-up in the non-AC group within the global cohort (P=0.003), whereas it remained stable over time in the AC group (P=0.323). The incidence of VHD was significantly lower in the AC group (0.6%) compared with the non-AC group (3.7%, P<0.001), and these significant differences remained within the propensity-matched populations (0.6% vs 3.9% in the AC and non-AC groups, respectively, P<0.001). The occurrence of VHD did not associate with an increased risk of all-cause death (P=0.468), cardiovascular death (P=0.539) or stroke (P=0.170) at follow-up. The lack of anticoagulation therapy post-TAVR was associated with significant increments in transvalvular gradients and a greater risk of VHD. VHD was subclinical in most cases and did not associate with major adverse clinical events. Future randomised trials are needed to determine if systematic anticoagulation therapy post-TAVR would reduce the incidence of VHD. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article

  1. Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.

    PubMed

    Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas

    2017-06-01

    Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.

  2. Stentless vs. stented bioprosthesis for aortic valve replacement: A case matched comparison of long-term follow-up and subgroup analysis of patients with native valve endocarditis.

    PubMed

    Schaefer, Andreas; Dickow, Jannis; Schoen, Gerhard; Westhofen, Sumi; Kloss, Lisa; Al-Saydali, Tarik; Reichenspurner, Hermann; Philipp, Sebastian A; Detter, Christian

    2018-01-01

    Current retrospective evidence suggests similar clinical and superior hemodynamic outcomes of the Sorin Freedom Solo stentless aortic valve (SFS) (LivaNova PLC, London, UK) compared to the Carpentier Edwards Perimount stented aortic valve (CEP) (Edwards Lifesciences Inc., Irvine, California, USA). To date, no reports exist describing case-matched long-term outcomes and analysis for treatment of native valve endocarditis (NVE). From 2004 through 2014, 77 consecutive patients (study group, 59.7% male, 68.9 ± 12.5 years, logEuroSCORE II 7.6 ± 12.3%) received surgical aortic valve replacement (SAVR) with the SFS. A control group of patients after SAVR with the CEP was retrieved from our database and matched to the study group regarding 15 parameters including preoperative endocarditis. Acute perioperative outcomes and follow-up data (mean follow-up time 48.7±29.8 months, 95% complete) were retrospectively analyzed. No differences in early mortality occurred during 30-day follow up (3/77; 3.9% vs. 4/77; 5.2%; p = 0.699). Echocardiographic findings revealed lower postprocedural transvalvular pressure gradients (max. 17.0 ± 8.2 vs. 24.5 ± 9.2 mmHg, p< 0.001/ mean pressure of 8.4 ± 4.1 vs. 13.1 ± 5.9 mmHg, p< 0.001) in the SFS group. Structural valve degeneration (SVD) (5.2% vs. 0%; p = 0.04) and valve explantation due to SVD or prosthetic valve endocarditis (PVE) (9.1% vs. 1.3%; p = 0.04) was more frequent in the SFS group. All-cause mortality during follow-up was 20.8% vs. 14.3% (p = 0.397). When patients were divided into subgroups of NVE and respective utilized bioprosthesis, the SFS presented impaired outcomes regarding mortality in NVE cases (p = 0.031). The hemodynamic superiority of the SFS was confirmed in this comparison. However, clinical outcomes in terms of SVD and PVE rates, as well as survival after NVE, were inferior in this study. Therefore, we are reluctant to recommend utilization of the SFS for treatment of NVE.

  3. Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance study

    PubMed Central

    Fairbairn, Timothy A; Steadman, Christopher D; Mather, Adam N; Motwani, Manish; Blackman, Daniel J; Plein, Sven; McCann, Gerry P; Greenwood, John P

    2013-01-01

    Objective To compare the effects of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) on aortic valve haemodynamics, ventricular reverse remodelling and myocardial fibrosis (MF) by cardiovascular magnetic resonance (CMR) imaging. Design A 1.5 T CMR scan was performed preoperatively and 6 months postoperatively. Setting University hospitals of Leeds and Leicester, UK. Patients 50 (25 TAVI, 25 SAVR; age 77±8 years) high-risk severe symptomatic aortic stenosis (AS) patients. Main outcome measures Valve haemodynamics, ventricular volumes, ejection fraction (EF), mass and MF. Results Patients were matched for gender and AS severity but not for age (80±6 vs 73±7 years, p=0.001) or EuroSCORE (22±14 vs 7±3, p<0.001). Aortic valve mean pressure gradient decreased to a greater degree post-TAVI compared to SAVR (21±8 mm Hg vs 35±13 mm Hg, p=0.017). Aortic regurgitation reduced by 8% in both groups, only reaching statistical significance for TAVI (p=0.003). TAVI and SAVR improved (p<0.05) left ventricular (LV) end-systolic volumes (46±18 ml/m2 vs 41±17 ml/m2; 44±22 ml/m2 vs32±6 ml/m2) and mass (83±20 g/m2 vs 65±15 g/m2; 74±11 g/m2 vs 59±8 g/m2). SAVR reduced end-diastolic volumes (92±19 ml/m2 vs 74±12 ml/m2, p<0.001) and TAVI increased EF (52±12% vs 56±10%, p=0.01). MF reduced post-TAVI (10.9±6% vs 8.5±5%, p=0.03) but not post-SAVR (4.2±2% vs 4.1±2%, p=0.98). Myocardial scar (p≤0.01) and baseline ventricular volumes (p<0.001) were the major predictors of reverse remodelling. Conclusions TAVI was comparable to SAVR at LV reverse remodelling and superior at reducing the valvular pressure gradient and MF. Future work should assess the prognostic importance of reverse remodelling and fibrosis post-TAVI to aid patient selection. PMID:23749779

  4. Early Left and Right Ventricular Response to Aortic Valve Replacement.

    PubMed

    Duncan, Andra E; Sarwar, Sheryar; Kateby Kashy, Babak; Sonny, Abraham; Sale, Shiva; Alfirevic, Andrej; Yang, Dongsheng; Thomas, James D; Gillinov, Marc; Sessler, Daniel I

    2017-02-01

    The immediate effect of aortic valve replacement (AVR) for aortic stenosis on perioperative myocardial function is unclear. Left ventricular (LV) function may be impaired by cardioplegia-induced myocardial arrest and ischemia-reperfusion injury, especially in patients with LV hypertrophy. Alternatively, LV function may improve when afterload is reduced after AVR. The right ventricle (RV), however, experiences cardioplegic arrest without benefiting from improved loading conditions. Which of these effects on myocardial function dominate in patients undergoing AVR for aortic stenosis has not been thoroughly explored. Our primary objective is thus to characterize the effect of intraoperative events on LV function during AVR using echocardiographic measures of myocardial deformation. Second, we evaluated RV function. In this supplementary analysis of 100 patients enrolled in a clinical trial (NCT01187329), 97 patients underwent AVR for aortic stenosis. Of these patients, 95 had a standardized intraoperative transesophageal echocardiographic examination of systolic and diastolic function performed before surgical incision and repeated after chest closure. Echocardiographic images were analyzed off-line for global longitudinal myocardial strain and strain rate using 2D speckle-tracking echocardiography. Myocardial deformation assessed at the beginning of surgery was compared with the end of surgery using paired t tests corrected for multiple comparisons. LV volumes and arterial blood pressure decreased, and heart rate increased at the end of surgery. Echocardiographic images were acceptable for analysis in 72 patients for LV strain, 67 for LV strain rate, and 54 for RV strain and strain rate. In 72 patients with LV strain images, 9 patients required epinephrine, 22 required norepinephrine, and 2 required both at the end of surgery. LV strain did not change at the end of surgery compared with the beginning of surgery (difference: 0.7 [97.6% confidence interval, -0.2 to 1

  5. Pulmonary Vascular Input Impedance is a Combined Measure of Pulmonary Vascular Resistance and Stiffness and Predicts Clinical Outcomes Better than PVR Alone in Pediatric Patients with Pulmonary Hypertension

    PubMed Central

    Hunter, Kendall S.; Lee, Po-Feng; Lanning, Craig J.; Ivy, D. Dunbar; Kirby, K. Scott; Claussen, Lori R.; Chan, K. Chen; Shandas, Robin

    2011-01-01

    Background Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated an method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero-harmonic impedance value and PVR, and suggested a correlation between higher harmonic impedance values and pulmonary vascular stiffness (PVS). Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and PVS from a single measurement, and that impedance is a better predictor of disease outcomes compared to PVR. Methods Pressure and velocity waveforms within the main PA were measured during right-heart catheterization of patients with normal PA hemodynamics (n=14) and those with PAH undergoing reactivity evaluation (49 subjects; 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Results Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y=1.095·x+1.381, R2=0.9620). Additionally, the modulus sum of the first two harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (PP/SV) (y=13.39·x-0.8058, R2=0.7962). Amongst a subset of PAH patients (n=25), cumulative logistic regression between outcomes to total indexed impedance was better (RL2=0.4012) than between outcomes and indexed PVR (RL2=0.3131). Conclusions Input impedance can be consistently and easily obtained from PW Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and better predicts patient

  6. Double valve replacement in a patient with implantable cardioverter defibrillator with severe left ventricular dysfunction.

    PubMed

    Manjunath, Girish; Rao, Prakash; Prakash, Nagendra; Shivaram, B K

    2016-01-01

    Recent data from landmark trials suggest that the indications for cardiac pacing and implantable cardioverter defibrillators (ICDs) are set to expand to include heart failure, sleep-disordered breathing, and possibly routine implantation in patients with myocardial infarction and poor ventricular function.[1] This will inevitably result in more patients with cardiac devices undergoing surgeries. Perioperative electromagnetic interference and their potential effects on ICDs pose considerable challenges to the anesthesiologists.[2] We present a case of a patient with automatic ICD with severe left ventricular dysfunction posted for double valve replacement.

  7. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    PubMed Central

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  8. Dysfunction of an On-X Heart Valve by Pannus.

    PubMed

    Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria

    2016-09-01

    A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.

  9. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    PubMed Central

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  10. Assessment of quality of life in patients after surgical and transcatheter aortic valve replacement.

    PubMed

    Tokarek, Tomasz; Siudak, Zbigniew; Dziewierz, Artur; Sobczyński, Robert; Zasada, Wojciech; Sorysz, Danuta; Olszewska-Wityńska, Katarzyna; Bryniarski, Krzysztof; Krawczyk-Ożóg, Agata; Żabówka, Anna; Sadowski, Jerzy; Dudek, Dariusz

    2016-09-01

    Transcatheter aortic valve implantation (TAVI) and minimally invasive aortic valve replacement (mini-thoracotomy, mini-sternotomy, MIAVR) have become an appealing alternative to conventional surgical (SAVR) treatment of severe aortic stenosis (AS) in high-risk patients. Aim of the study was to evaluate the quality of life (QoL) in patients with AS and treated with transfemoral TAVI, SAVR, mini-thoracotomy and mini-sternotomy. One hundred and seventy-three patients with symptomatic AS were enrolled in 2011-2013. TAVI group consisted of 39 patients (22.5%), mini-sternotomy was performed in 44 patients (25.5%), mini-thoracotomy in 50 (29%), and AVR in 40 patients (23%). QoL was assessed perioperatively, 12 and 24 months after aortic valve replacement (AVR) by Minnesota Living with Heart Failure Questionnaire (MLHFQ) and EQ-5D-3L. Median follow-up was 583.5 (IQR: 298-736) days. Improvement of health status after procedure in comparison with pre-operative period was significantly more often reported after TAVI in perioperative period (90.3%; P = 0.004) and 12 months after procedure (100%, P = 0.02). Global MLHFQ, physical and emotional dimension score at 30-day from AVR presented significant improvement after TAVI in comparison with surgical methods (respectively: 8.3(±8.6), P = 0.003; 4.1(±5.9), P = 0.01; 1.5(±2.6), P = 0.005). Total MLHFQ score was significantly lower (better outcome) in TAVI patients 1 year after procedure (4.8(±6.8), P = 0.004), no differences in somatic and emotional component were found. No differences were found in MLHFQ score 24 months after AVR. Data from EQ-D5-3L questionnaire demonstrated significant improvement of QoL at 30-day follow-up after TAVI in comparison with surgical methods (1.2(±1.7), P = 0.0008). TAVI improves QoL in perioperative and 12 months observation in comparison with mini-thoracotomy, mini-sternotomy and SAVR. Improvement in QoL was obtained in both generic and disease specific

  11. The role of risk factors and trigger factors in cerebrovascular events after mitral valve replacement: implications for antithrombotic management.

    PubMed

    Butchart, E G; Moreno de la Santa, P; Rooney, S J; Lewis, P A

    1994-03-01

    To determine the effect of risk factors and trigger factors on cerebrovascular events, 622 patients who survived mitral valve replacement between December 1979 and December 1992 were analyzed. Ninety-six patients suffered 139 nonhemorrhagic cerebrovascular events. Data were available on 138 events in 95 patients. There were 32 transient ischemic attacks (TIAs), 57 reversible ischemic neurological deficits (RINDs), and 49 strokes. Age, sex, atrial fibrillation, left atrial size, systemic hypertension, and abnormal body mass index did not discriminate between patients who suffered events and those who did not. In contrast, smoking status differed significantly between patients who suffered events and those who did not. Among current or recent ex-smokers, the risk of stroke or RIND was significantly higher than in non-smokers (p < < 0.001). The odds ratio of suffering any type of event in patients who smoked at any time postoperatively versus those who did not smoke was 2.9 (95% confidence interval: 1.8 to 4.6). Of 61 patients contacted directly, 30% recalled an infective episode immediately prior to their event. A diurnal and seasonal influence on events was also detected with peaks in the morning and in the winter months, respectively (both p < 0.001). It is concluded that there is persuasive evidence for the involvement of several nonprosthetic factors in the incidence of cerebrovascular events after mitral valve replacement. This has implications for patient management and for future analysis of prosthetic heart valve series.

  12. Aortic valve ochronosis: a rare manifestation of alkaptonuria

    PubMed Central

    Steger, Christina Maria

    2011-01-01

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed. PMID:22689837

  13. Aortic valve ochronosis: a rare manifestation of alkaptonuria.

    PubMed

    Steger, Christina Maria

    2011-07-28

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.

  14. Correlation between plasma N-terminal pro-brain natriuretic peptide levels and changes in New York Heart Association functional class, left atrial size, left ventricular size and function after mitral and/or aortic valve replacement.

    PubMed

    Elasfar, Abdelfatah

    2012-01-01

    Elevated plasma brain natriuretic peptide (BNP) levels have been demonstrated in patients with chronic valvular disease. We designed the present study to assess whether changes in N-terminal pro-brain natriuretic peptide (NT-proBNP) levels after mitral, aortic and double mitral and aortic valve replacement reflect changes in heart failure (HF) symptoms including New York Heart Association (NYHA) class and changes in left atrium (LA) size, left ventricle (LV) size and LV function. A prospective observational nonrandomized study among consecutive patients undergoing mitral and/or aortic valve replacement in our center. The study population consisted of 24 patients (mean [SD] age of 55.3 [16.2] years, 58% were males) who underwent surgical mitral valve replacement (12 patients), aortic valve replacement (8 patients) and combined mitral and aortic valve replacement (4 patients). NT-proBNP measurements, transthoracic echocardiography and NYHA class assessments were performed before and 6 months after surgery. The decrease in NT-proBNP was associated with decrease in left atrial dimension (r = 0.73, P < .002), LV end-diastolic dimension (r=0.65, P=.001), LV end-systolic dimension (r=0.53, P=.036), and increase in ejection fraction (r=-0.65, P=.001) after 6 months postoperatively. Furthermore, a decreasing NT-proBNP was associated with improvement in NYHA class. NT-proBNP levels after mitral, aortic and double valve replacement correlates with changes in HF manifestations as well as changes in LA size and LV dimension and function. Thus, we hypothesize that interval measurement of the NT-proBNP level at clinic visits can allow early detection of any clinical deterioration as well as the possibility of assessment of the long-term outcome of those patients.

  15. Valve sparing aortic replacement - root remodeling.

    PubMed

    Lausberg, Henning F; Schäfers, Hans-Joachim

    2006-01-01

    Aortic root remodeling restores aortic root geometry and improves valve competence. We have used this technique whenever aorto-ventricular diameter is preserved. The operative technique is detained in this presentation. As a result of our 10-year experience with root remodeling we propose this operation as a reproducible option for patients with dilatation of the aortic root.

  16. Aortic expansion rate in patients with dilated post-stenotic ascending aorta submitted only to aortic valve replacement long-term follow-up.

    PubMed

    Gaudino, Mario; Anselmi, Amedeo; Morelli, Mauro; Pragliola, Claudio; Tsiopoulos, Vasileios; Glieca, Franco; Possati, Gianfederico

    2011-08-02

    This study was conceived to describe the evolution of aortic dimensions in patients with moderate post-stenotic ascending aorta dilation (50 to 59 mm) submitted to aortic valve replacement (AVR) alone. The appropriate treatment of post-stenotic ascending aorta dilation has been poorly investigated. Ninety-three patients affected by severe isolated calcific aortic valve stenosis in the tricuspid aortic valve accompanied by moderate dilation of the ascending aorta (50 to 59 mm) were submitted to AVR only. All patients were followed for a mean of 14.7 ± 4.8 years by means of periodic clinical evaluations and echocardiography and tomography scans of the thorax. Operative mortality was 1.0% (1 patient). During the follow-up, 16 patients died and 2 had to be reoperated for valve dysfunction. No patients experienced acute aortic events (rupture, dissection, pseudoaneurysm), and no patient had to be reoperated on the aorta. There was not a substantial increase in aortic dimensions: mean aortic diameter was 57 ± 11 mm at the end of the follow-up versus 56 ± 02 mm pre-operatively (p = NS). The mean ascending aorta expansion rate was 0.3 ± 0.2 mm/year. In the absence of connective tissue disorders, AVR alone is sufficient to prevent further aortic expansion in patients with moderate post-stenotic dilation of the ascending aorta. Aortic replacement can probably be reserved for patients with a long life expectancy. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR/TAVI): analysis of interchangeability.

    PubMed

    Lou, Junyang; Obuchowski, Nancy A; Krishnaswamy, Amar; Popovic, Zoran; Flamm, Scott D; Kapadia, Samir R; Svensson, Lars G; Bolen, Michael A; Desai, Milind Y; Halliburton, Sandra S; Tuzcu, E Murat; Schoenhagen, Paul

    2015-01-01

    Preprocedural 3-dimensional CT imaging of the aortic annular plane plays a critical role for transcatheter aortic valve replacement (TAVR) planning; however, manual reconstructions are complex. Automated analysis software may improve reproducibility and agreement between readers but is incompletely validated. In 110 TAVR patients (mean age, 81 years; 37% female) undergoing preprocedural multidetector CT, automated reconstruction of the aortic annular plane and planimetry of the annulus was performed with a prototype of now commercially available software (syngo.CT Cardiac Function-Valve Pilot; Siemens Healthcare, Erlangen, Germany). Fully automated, semiautomated, and manual annulus measurements were compared. Intrareader and inter-reader agreement, intermodality agreement, and interchangeability were analyzed. Finally, the impact of these measurements on recommended valve size was evaluated. Semiautomated analysis required major correction in 5 patients (4.5%). In the remaining 95.5%, only minor correction was performed. Mean manual annulus area was significantly smaller than fully automated results (P < .001 for both readers) but similar to semiautomated measurements (5.0 vs 5.4 vs 4.9 cm(2), respectively). The frequency of concordant recommendations for valve size increased if manual analysis was replaced with the semiautomated method (60% agreement was improved to 82.4%; 95% confidence interval for the difference [69.1%-83.4%]). Semiautomated aortic annulus analysis, with minor correction by the user, provides reliable results in the context of TAVR annulus evaluation. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  18. Concomitant coronary artery bypass graft and aortic and mitral valve replacement for rheumatic heart disease: short- and mid-term outcomes.

    PubMed

    Davarpasand, Tahereh; Hosseinsabet, Ali; Jalali, Arash

    2015-09-01

    It has been reported that the short-term mortality of concomitant aortic and mitral valve replacement (AVR and MVR) is considerable and concomitant coronary artery bypass graft (CABG) has adverse effects on the survival of patients with valve replacement surgery. We summarize the short- and mid-term outcome after concomitant CABG, AVR and MVR in our centre. Between 2003 and 2013, 103 patients (68 males, 35 females, age: 60.1 ± 10.1 years) underwent CABG, AVR and MVR for rheumatic heart disease (RHD) and coronary artery disease (CAD). The median follow-up was 47.6 months. Most of the patients were asymptomatic at rest. We analysed demographic, clinical and operative data of patients to define independent predictors of overall survival, cardiac event-free survival as well as cardiac death. The rate of 30-day survival was 93% (n = 96). The corresponding rates of overall survival and cardiac event-free survival and the cumulative incidence rate of cardiac death at 1 year were 80.2, 77.3 and 10.9%; the same at 4 years were 73.7, 64.6 and 15.8%. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 96.2, 95.3, 94.7, 81.6 and 97.7% at 1 year. The corresponding freedom rates from anticoagulation-associated major haemorrhage; a composite of major bleeding events, thromboemboli and valvular thrombosis; cardiac rehospitalization; major adverse valve-associated events; and significant malfunction of the prosthetic valve were 93.5, 91.0, 91.4, 73.5 and 95.5% at 4 years. The independent predictors of overall survival were age, cigarette smoking, chronic kidney diseases and balloon pump insertion. The independent predictors of cardiac event-free survival were age and previous myocardial infarction, while age, cigarette smoking, history of cerebrovascular

  19. Costs of periprocedural complications in patients treated with transcatheter aortic valve replacement: results from the Placement of Aortic Transcatheter Valve trial.

    PubMed

    Arnold, Suzanne V; Lei, Yang; Reynolds, Matthew R; Magnuson, Elizabeth A; Suri, Rakesh M; Tuzcu, E Murat; Petersen, John L; Douglas, Pamela S; Svensson, Lars G; Gada, Hemal; Thourani, Vinod H; Kodali, Susheel K; Mack, Michael J; Leon, Martin B; Cohen, David J

    2014-12-01

    In patients with severe aortic stenosis, transcatheter aortic valve replacement (TAVR) improves survival when compared with nonsurgical therapy but with higher in-hospital and lifetime costs. Complications associated with TAVR may decrease with greater experience and improved devices, thereby reducing the overall cost of the procedure. Therefore, we sought to estimate the effect of periprocedural complications on in-hospital costs and length of stay of TAVR. Using detailed cost data from 406 TAVR patients enrolled in the Placement of Aortic Transcatheter Valve (PARTNER) I trial, we developed multivariable models to estimate the incremental cost and length of stay associated with specific periprocedural complications. Attributable costs and length of stay for each complication were calculated by multiplying the independent cost of each event by its frequency in the treatment group. Mean cost for the initial hospitalization was $79 619±40 570 ($50 891 excluding the valve); 49% of patients had ≥1 complication. Seven complications were independently associated with increased hospital costs, with major bleeding, arrhythmia, and death accounting for the largest attributable cost per patient. Renal failure and the need for repeat TAVR, although less frequent, were also associated with substantial incremental and attributable costs. Overall, complications accounted for $12 475 per patient in initial hospital costs and 2.4 days of hospitalization. In the PARTNER trial, periprocedural complications were frequent, costly, and accounted for ≈25% of non-implant-related hospital costs. Avoidance of complications should improve the cost-effectiveness of TAVR for inoperable and high-risk patients, but reductions in the cost of uncomplicated TAVR will also be necessary for optimal efficiency. http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2014 American Heart Association, Inc.

  20. The flaws in the detail of an observational study on transcatheter aortic valve implantation versus surgical aortic valve replacement in intermediate-risks patients.

    PubMed

    Barili, Fabio; Freemantle, Nick; Folliguet, Thierry; Muneretto, Claudio; De Bonis, Michele; Czerny, Martin; Obadia, Jean Francois; Al-Attar, Nawwar; Bonaros, Nikolaos; Kluin, Jolanda; Lorusso, Roberto; Punjabi, Prakash; Sadaba, Rafael; Suwalski, Piotr; Benedetto, Umberto; Böning, Andreas; Falk, Volkmar; Sousa-Uva, Miguel; Kappetein, Pieter A; Menicanti, Lorenzo

    2017-06-01

    The PARTNER group recently published a comparison between the latest generation SAPIEN 3 transcatheter aortic valve implantation (TAVI) system (Edwards Lifesciences, Irvine, CA, USA) and surgical aortic valve replacement (SAVR) in intermediate-risk patients, apparently demonstrating superiority of the TAVI and suggesting that TAVI might be the preferred treatment method in this risk class of patients. Nonetheless, assessment of the non-randomized methodology used in this comparison reveals challenges that should be addressed in order to elucidate the validity of the results. The study by Thourani and colleagues showed several major methodological concerns: suboptimal methods in propensity score analysis with evident misspecification of the propensity scores (PS; no adjustment for the most significantly different covariates: left ventricular ejection fraction, moderate-severe mitral regurgitation and associated procedures); use of PS quintiles rather than matching; inference on not-adjusted Kaplan-Meier curves, although the authors correctly claimed for the need of balancing score adjusting for confounding factors in order to have unbiased estimates of the treatment effect; evidence of poor fit; lack of data on valve-related death.These methodological flaws invalidate direct comparison between treatments and cannot support authors' conclusions that TAVI with SAPIEN 3 in intermediate-risk patients is superior to surgery and might be the preferred treatment alternative to surgery. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Transcatheter Aortic Valve Replacement Improves Health Status in Elderly Veterans.

    PubMed

    Gurevich, Sergey; Reiff, Chris; Bertog, Stefan; Mbai, Mackenzie; Kelly, Rosemary F; Soule, Matthew; Yannopoulos, Demetris; Garcia, Santiago

    2018-06-01

    United States veterans have substantially worse baseline health status than the general population, which may limit the health benefits of transcatheter aortic valve replacement (TAVR). The aim of this study is to quantify the health benefits of TAVR in veterans undergoing the procedure within the United States Department of Veterans Affairs (VA) health-care system. We prospectively evaluated heath status in 131 elderly veterans undergoing TAVR in the VA healthcare system between 2015 and 2017. Health status was assessed at baseline and 30 days post procedure using the Kansas City Cardiomyopathy Questionnaire 12 (KCCQ-12). Totals and domain-specific (physical limitation, symptoms, quality of life, and social limitation) health statuses were measured and analyzed with a paired t-test. We also conducted stratified analysis by baseline New York Heart Association functional class and N-terminal pro-b type natriuretic peptide levels. Mean patient age was 77 ± 8 years and average Society of Thoracic Surgeons (STS) score was 4.4 (interquartile range, 3-7). Transfemoral access and balloon-expandable valves were used in 118 cases (92%) and 108 cases (83%), respectively. At baseline, overall health status was poor (overall score, 43 ± 19). After TAVR, significant improvements in overall health status (30 ± 18) and domain-specific health status were seen (improvements in physical limitation, 12 ± 20; symptoms, 23 ± 23; quality of life, 20 ± 17; social limitation, 22 ± 21; all P<.001). The majority of patients (88%) had moderate to large improvements in health status. A favorable outcome (alive with KCCQ-12 overall score >60 at 30 days) was seen in 78% of patients. Among elderly veterans with severe aortic stenosis, TAVR is associated with significant improvements in short-term health status.

  2. A Quantitative RNAi Screen for JNK Modifiers Identifies Pvr as a Novel Regulator of Drosophila Immune Signaling

    PubMed Central

    Bond, David; Foley, Edan

    2009-01-01

    Drosophila melanogaster responds to gram-negative bacterial challenges through the IMD pathway, a signal transduction cassette that is driven by the coordinated activities of JNK, NF-κB and caspase modules. While many modifiers of NF-κB activity were identified in cell culture and in vivo assays, the regulatory apparatus that determines JNK inputs into the IMD pathway is relatively unexplored. In this manuscript, we present the first quantitative screen of the entire genome of Drosophila for novel regulators of JNK activity in the IMD pathway. We identified a large number of gene products that negatively or positively impact on JNK activation in the IMD pathway. In particular, we identified the Pvr receptor tyrosine kinase as a potent inhibitor of JNK activation. In a series of in vivo and cell culture assays, we demonstrated that activation of the IMD pathway drives JNK-dependent expression of the Pvr ligands, Pvf2 and Pvf3, which in turn act through the Pvr/ERK MAP kinase pathway to attenuate the JNK and NF-κB arms of the IMD pathway. Our data illuminate a poorly understood arm of a critical and evolutionarily conserved innate immune response. Furthermore, given the pleiotropic involvement of JNK in eukaryotic cell biology, we believe that many of the novel regulators identified in this screen are of interest beyond immune signaling. PMID:19893628

  3. Leaflet escape in a new bileaflet mechanical valve: TRI technologies.

    PubMed

    Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino

    2003-05-13

    Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.

  4. Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

    PubMed

    Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari

    2017-06-01

    Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.

  5. Aortic valve repair using a differentiated surgical strategy.

    PubMed

    Langer, Frank; Aicher, Diana; Kissinger, Anke; Wendler, Olaf; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-09-14

    Reconstruction of the aortic valve for aortic regurgitation (AR) remains challenging, in part because of not only cusp or root pathology but also a combination of both can be responsible for this valve dysfunction. We have systematically tailored the repair to the individual pathology of cusps and root. Between October 1995 and August 2003, aortic valve repair was performed in 282 of 493 patients undergoing surgery for AR and concomitant disease. Root dilatation was corrected by subcommissural plication (n=59), supracommissural aortic replacement (n=27), root remodeling (n=175), or valve reimplantation within a graft (n=24). Cusp prolapse was corrected by plication of the free margin (n=157) or triangular resection (n =36), cusp defects were closed with a pericardial patch (n=16). Additional procedures were arch replacement (n=114), coronary artery bypass graft (n=60) or mitral repair (n=24). All patients were followed-up (follow-up 99.6% complete), and cumulative follow-up was 8425 patient-months (mean, 33+/-27 months).Results- Eleven patients died in hospital (3.9%). Nine patients underwent reoperation for recurrent AR (3.3%). Actuarial freedom from AR grade > or =II at 5 years was 81% for isolated valve repair, 84% for isolated root replacement, and 94% for combination of both; actuarial freedom from reoperation at 5 years was 93%, 95%, and 98%, respectively. No thromboembolic events occurred, and there was 1 episode of endocarditis 4.5 years postoperatively. Aortic valve repair is feasible even for complex mechanisms of AR with a systematic and individually tailored approach. Operative mortality is low and mid-term durability is encouraging. The incidence of valve-related morbidity is low compared with valve replacement.

  6. Five-year results after valve replacement with the Björk-Shiley 70 degrees convexo-concave prosthesis.

    PubMed

    Koldsland, S; Svennevig, J L; Abdelnoor, M; Aas, H; Semb, G

    1992-01-01

    In the 18 months up to July 1983, 120 Björk-Shiley convexo-concave prostheses with 70 degrees opening angle were implanted in 47 women and 61 men aged 19-78 (mean 58.6) years. The prosthetic valves were aortic in 65 cases, mitral in 23 and both aortic and mitral in 20 cases. Emergency operation was required in ten cases, and concomitant surgery was performed in 43 (39.8%). The early mortality was 5.5%. A follow-up study, comprising 498 patient years, revealed 73.1% 5-year survival. There were three mechanical failures of prosthesis, in one of which re-replacement was successful. Elective prosthesis replacement was performed in four other cases judged to be at high risk of strut fracture.

  7. Thromboembolism in patients with pericardial valves in the absence of chronic anticoagulation: 12 years' experience.

    PubMed

    García-Bengoechea, J B; González-Juanatey, J R; Rubio, J; Durán, D; Sierra, J

    1991-01-01

    Between January 1977 and January 1989, 465 pericardial bioprostheses were implanted in 424 patients. The mean age of patients was 59.1 years (range 16-81 y.) At the time of surgery, 68% of the patients suffered from chronic atrial fibrillation. Mitral valve replacement was performed in 167 patients, aortic valve replacement in 216, multiple replacement in 40 (36 mitral and aortic, 3 mitral and tricuspid, and 1 mitral, aortic and tricuspid), and 1 pulmonary valve replacement. The different types of pericardial valve used were: Ionescu-Shiley 408, Mitral Medical 23, Bioflo 30, and Hancock 4. Hospital mortality was 10.1% with an attrition rate of 1.8 episodes per 100 patients/year. The 12-year actuarial survival rate was 65.1%. No patient underwent long-term anticoagulant treatment. The first 144 patients undergoing mitral and multiple valve replacements received temporary anticoagulation for the first 8 weeks after surgery. There was no valve thrombosis observed. Altogether 19 thromboembolic events (6 early and 13 late) were clinically documented. One patient died after an embolic event. The linearized rates of thromboembolism were 1.64 episodes per 100 patients/year for mitral and multiple valve replacements and 0.33 episodes per 100 patients/year for aortic valve replacement, with an overall rate of 1.0 episodes per 100 patients/year. Excluding early thromboembolism, the linearized rate was 1.02 episodes per 100 patients/year overall. The actuarial freedom from embolism was 92.4% overall, 88.2% for the mitral and multiple valve replacement group, and 97.6% for the aortic valve replacement group at a maximum follow-up of 12 years.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    PubMed

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  9. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    PubMed

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Multidetector computed tomography sizing of aortic annulus prior to transcatheter aortic valve replacement (TAVR): Variability and impact of observer experience.

    PubMed

    Le Couteulx, S; Caudron, J; Dubourg, B; Cauchois, G; Dupré, M; Michelin, P; Durand, E; Eltchaninoff, H; Dacher, J-N

    2018-05-01

    To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve. Copyright © 2017. Published by Elsevier Masson SAS.

  11. Revisiting Sex Equality With Transcatheter Aortic Valve Replacement Outcomes: A Collaborative, Patient-Level Meta-Analysis of 11,310 Patients.

    PubMed

    O'Connor, Stephen A; Morice, Marie-Claude; Gilard, Martine; Leon, Martin B; Webb, John G; Dvir, Danny; Rodés-Cabau, Josep; Tamburino, Corrado; Capodanno, Davide; D'Ascenzo, Fabrizio; Garot, Philippe; Chevalier, Bernard; Mikhail, Ghada W; Ludman, Peter F

    2015-07-21

    There has been conflicting clinical evidence as to the influence of female sex on outcomes after transcatheter aortic valve replacement. The aim of this study was to evaluate the impact of sex on early and late mortality and safety end points after transcatheter aortic valve replacement using a collaborative meta-analysis of patient-level data. From the MEDLINE, Embase, and the Cochrane Library databases, data were obtained from 5 studies, and a database containing individual patient-level time-to-event data was generated from the registry of each selected study. The primary outcome of interest was all-cause mortality. The safety end point was the combined 30-day safety end points of major vascular complications, bleeding events, and stroke, as defined by the Valve Academic Research Consortium when available. Five studies and their ongoing registry data, comprising 11,310 patients, were included. Women constituted 48.6% of the cohort and had fewer comorbidities than men. Women had a higher rate of major vascular complications (6.3% vs. 3.4%; p < 0.001), major bleeding events (10.5% vs. 8.5%; p = 0.003), and stroke (4.4% vs. 3.6%; p = 0.029) but a lower rate of significant aortic incompetence (grade ≥2; 19.4% vs. 24.5%; p < 0.001). There were no differences in procedural and 30-day mortality between women and men (2.6 % vs. 2.2% [p = 0.24] and 6.5% vs. 6.5% [p = 0.93], respectively), but female sex was independently associated with improved survival at median follow-up of 387 days (interquartile range: 192 to 730 days) from the index procedure (adjusted hazard ratio: 0.79; 95% confidence interval: 0.73 to 0.86; p = 0.001). Although women experience more bleeding events, as well as vascular and stroke complications, female sex is an independent predictor of late survival after transcatheter aortic valve replacement. This should be taken into account during patient selection for this procedure. Copyright © 2015 American College of Cardiology Foundation

  12. Predictor of left ventricular dysfunction after aortic valve replacement in mixed aortic valve disease.

    PubMed

    Egbe, Alexander C; Warnes, Carole A

    2017-02-01

    The fate of the left ventricle (LV) after aortic valve replacement (AVR) in mixed aortic valve disease (MAVD) is unknown. Patients with moderate-severe MAVD, ejection fraction ≥50%, and no coronary artery disease who underwent AVR were identified. Moderate-severe MAVD was defined as a combination of ≥moderate aortic stenosis and ≥moderate aortic regurgitation. Assessment for LVD was performed at 1 and 5years after AVR. The purpose of the study was to determine prevalence and predictors of early and late left ventricular dysfunction (LVD) defined as ejection fraction <50% at 1 and 5years post-AVR. The severity of LV hypertrophy was assessed using LV mass index (LVMI), while relative wall thickness (RWT) was used to determine the type of hypertrophy. RWT was calculated as (2×posterior wall thickness)/LV end-diastolic dimension (LVEDD). A RWT score ≥0.42 and <0.42 indicates concentric and eccentric hypertrophy respectively. Patients with MAVD (n=179); age 63±8years, males 134 (75%); underwent AVR at Mayo Clinic, 1994-2010. Early LVD occurred in 38(21%). Predictors of early LVD were LVMI/LVEDD >3.1 (HR 1.83, CI 1.59-1.98); RWT >0.46 (HR 2.16, CI 1.21-4.99); and older age (HR 1.62, CI 1.23-3.02). Assessment of LV function was performed in 124 patients at 5-years post-AVR, and late LVD was present in 29(23%). Predictors of late LVD were LVMI/LVEDD >3.1 (HR 1.77, CI 1.24-2.01) and RWT >0.46 (HR 1.65, CI 1.29-2.24). All-cause mortality occurred in 21(12%), and was more common in patients with LVMI/LVEDD >3.1 (P=0.043) and RWT >0.46 (P=0.029). Patients with postoperative LVD showed less regression of LV mass after AVR even after controlling for blood pressure. LVD can occur after AVR even in the setting of normal preoperative LV function and absence of coronary artery disease. Preoperative LV mass was predictive of LVD and should be taken into consideration when determining the timing of AVR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Thirty-day readmissions in surgical and transcatheter aortic valve replacement: A systematic review and meta-analysis.

    PubMed

    Danielsen, Stein Ove; Moons, Philip; Sandven, Irene; Leegaard, Marit; Solheim, Svein; Tønnessen, Theis; Lie, Irene

    2018-05-17

    The 30-day all-cause readmission rate after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) vary substantially. We conducted a systematic review and meta-analysis to examine the overall incidence, causes, and risk factors of 30-day all-cause readmission rate after SAVR and TAVR. Eight medical research databases were searched; Cochrane, Medline, Embase, UpToDate, PROSPERO, National Guideline Clearinghouse, SweMed and Oria. We followed The Preferred Reporting Items for Systematic reviews and Meta-analysis (PRISMA) for this study. Thirty-three articles were included in the systematic review, 32 of which were appropriate for the meta-analysis. Overall, 17% (95% CI: 16-18%) of patients in the SAVR group, and 16% (95% CI: 15-18%) in the TAVR groups were readmitted within 30 days. Heart failure, arrhythmia, infection, and respiratory problems were the most frequent causes of all-cause readmission after SAVR and TAVR. Most frequent reported prior risk factors for all-cause readmission following TAVR were diabetes, chronic lung disease/chronic obstructive pulmonary disease, atrial fibrillation, kidney problems, and transapical approach/nonfemoral access. For SAVR, no risk factors for 30-day all-cause readmission were reported in the literature to date. In conclusion, the overall proportion of 30-day all-cause readmission after SAVR and TAVR are high. Interventions to prevent avoidable readmissions ought to be developed and implemented. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  15. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  16. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  17. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  18. 21 CFR 870.3935 - Prosthetic heart valve holder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prosthetic heart valve holder. 870.3935 Section... heart valve holder. (a) Identification. A prosthetic heart valve holder is a device used to hold a replacement heart valve while it is being sutured into place. (b) Classification. Class I. The device is...

  19. Long-term results of heart valve replacement with the Edwards Duromedics bileaflet prosthesis: a prospective ten-year clinical follow-up.

    PubMed

    Podesser, B K; Khuenl-Brady, G; Eigenbauer, E; Roedler, S; Schmiedberger, A; Wolner, E; Moritz, A

    1998-05-01

    The Edwards Duromedics valve (Baxter Healthcare Corp., Edwards Division, Santa Ana, Calif.) was designed with a self-irrigating hinge mechanism to reduce thromboembolic complications. After good initial clinical results, distribution was suspended in 1988 after reports of valve fracture after 20,000 valves had been implanted. The manufacturer conducted extensive studies to improve the Edwards Duromedics and reintroduced a modified version, which is available as Edwards Tekna. The purpose of the study was the evaluation of long-term results of the original Edwards Duromedics that might be important for the current version, the Edwards Tekna valve. A prospective clinical 10-year follow-up was performed of 508 patients who underwent valve replacement with the Edwards Duromedics valve in the aortic (n = 268), mitral (n = 183), and aortic and mitral (n = 56) position. The perioperative mortality rate was 6.9%; follow-up was 98% complete, comprising 3648 patient-years for a mean follow-up of 86 months (range: 33 to 144 months). The actuarial freedom from complications at the 10-year follow-up and the incidence rate (percent per patient-year) were as follows: late mortality rate, 69.2% +/- 2.4% (3.5% per patient-year); thromboembolism, 90.7% +/- 1.6% (0.96% per patient-year); anticoagulation-related hemorrhage, 87.7% +/- 1.7% (1.34% per patient-year); prosthetic valve endocarditis, 96.7% +/- 0.09% (0.38% per patient-year); valve-related mortality rate, 89.3% +/- 1.6% (1.21% per patient-year); valve failure, 86.2% +/- 1.85% (1.54% per patient-year); and valve-related morbidity and mortality rate, 71.1% +/- 2.3% (3.2% per patient-year). Three leaflet escapes were observed (one lethal, two successful reoperations; 99.1% +/- 0.05% freedom, 0.08% per patient-year). All patients functionally improved (86% in New York Heart Association classes I and II), and incidence of anemia was insignificant. These results confirm that the Edwards Duromedics valve shows excellent performance

  20. [Tricuspid valve insufficiency: what should be done?].

    PubMed

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  1. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium.

    PubMed

    Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T

    2017-04-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. The Impact of Obesity on Postoperative Outcomes in Adults with Congenital Heart Disease Undergoing Pulmonary Valve Replacement.

    PubMed

    Buelow, Matthew W; Earing, Michael G; Hill, Garick D; Cohen, Scott B; Bartz, Peter J; Tweddell, James S; Ginde, Salil

    2015-01-01

    The impact of obesity on surgical morbidity in adults with congenital heart disease is currently unknown. The aim of our study was to investigate the impact of obesity on postoperative outcomes in adults with congenital heart disease undergoing reoperation for pulmonary valve replacement. A retrospective analysis was performed assessing the influence of obesity on surgical outcomes. Obesity was defined as a body mass index ≥30 kg/m2. The mean body mass index of the cohort was 25.9 ± 6.9 kg/m2 . The cohort included 71 patients with 17 patients (24%) being obese. There was no postoperative mortality. Obese patients had a longer hospital length of stay (6.6 vs. 4.7 days; P < .001) and increased incidence of postoperative arrhythmias (29% vs. 5.6%; P = .003) compared with nonobese patients. Multivariable analysis performed using logistic regression with backwards elimination demonstrated obesity was independently associated with hospital length of stay >5 days (odds ratio [OR] = 5.2; 95% confidence interval [CI]: 1.5-18.2, P = .01) and with increased postoperative arrhythmias (OR = 4.2; 95% CI: 1.7-40, P < .01). Obesity is associated with increased morbidity in adults with congenital heart disease undergoing pulmonary valve replacement, including longer hospitalization and higher risk for postoperative arrhythmias. © 2015 Wiley Periodicals, Inc.

  3. Collagen Matrix Remodeling in Stented Pulmonary Arteries after Transapical Heart Valve Replacement.

    PubMed

    Ghazanfari, Samaneh; Driessen-Mol, Anita; Hoerstrup, Simon P; Baaijens, Frank P T; Bouten, Carlijn V C

    2016-01-01

    The use of valved stents for minimally invasive replacement of semilunar heart valves is expected to change the extracellular matrix and mechanical function of the native artery and may thus impair long-term functionality of the implant. Here we investigate the impact of the stent on matrix remodeling of the pulmonary artery in a sheep model, focusing on matrix composition and collagen (re)orientation of the host tissue. Ovine native pulmonary arteries were harvested 8 (n = 2), 16 (n = 4) and 24 (n = 2) weeks after transapical implantation of self-expandable stented heart valves. Second harmonic generation (SHG) microscopy was used to assess the collagen (re)orientation of fresh tissue samples. The collagen and elastin content was quantified using biochemical assays. SHG microscopy revealed regional differences in collagen organization in all explants. In the adventitial layer of the arterial wall far distal to the stent (considered as the control tissue), we observed wavy collagen fibers oriented in the circumferential direction. These circumferential fibers were more straightened in the adventitial layer located behind the stent. On the luminal side of the wall behind the stent, collagen fibers were aligned along the stent struts and randomly oriented between the struts. Immediately distal to the stent, however, fibers on both the luminal and the adventitial side of the wall were oriented in the axial direction, demonstrating the stent impact on the collagen structure of surrounding arterial tissues. Collagen orientation patterns did not change with implantation time, and biochemical analyses showed no changes in the trend of collagen and elastin content with implantation time or location of the vascular wall. We hypothesize that the collagen fibers on the adventitial side of the arterial wall and behind the stent straighten in response to the arterial stretch caused by oversizing of the stent. However, the collagen organization on the luminal side suggests that

  4. Surgical treatment of tricuspid regurgitation after mitral valve surgery: a retrospective study in China

    PubMed Central

    2012-01-01

    Background Functional tricuspid regurgitation (TR) occurs in patients with rheumatic mitral valve disease even after mitral valve surgery. The aim of this study was to analyze surgical results of TR after previous successful mitral valve surgery. Methods From September 1996 to September 2008, 45 patients with TR after previous mitral valve replacement underwent second operation for TR. In those, 43 patients (95.6%) had right heart failure symptoms (edema of lower extremities, ascites, hepatic congestion, etc.) and 40 patients (88.9%) had atrial fibrillation. Twenty-six patients (57.8%) were in New York Heart Association (NYHA) functional class III, and 19 (42.2%) in class IV. Previous operations included: 41 for mechanical mitral valve replacement (91.1%), 4 for bioprosthetic mitral valve replacement (8.9%), and 7 for tricuspid annuloplasty (15.6%). Results The tricuspid valves were repaired with Kay's (7 cases, 15.6%) or De Vega technique (4 cases, 8.9%). Tricuspid valve replacement was performed in 34 cases (75.6%). One patient (2.2%) died. Postoperative low cardiac output (LCO) occurred in 5 patients and treated successfully. Postoperative echocardiography showed obvious reduction of right atrium and ventricle. The anterioposterior diameter of the right ventricle decreased to 25.5 ± 7.1 mm from 33.7 ± 6.2 mm preoperatively (P < 0. 05). Conclusion TR after mitral valve replacement in rheumatic heart disease is a serious clinical problem. If it occurs or progresses late after mitral valve surgery, tricuspid valve annuloplasty or replacement may be performed with satisfactory results. Due to the serious consequence of untreated TR, aggressive treatment of existing TR during mitral valve surgery is recommended. PMID:22490269

  5. Prosthetic valve endocarditis due to Propionibacterium acnes.

    PubMed

    van Valen, Richard; de Lind van Wijngaarden, Robert A F; Verkaik, Nelianne J; Mokhles, Mostafa M; Bogers, Ad J J C

    2016-07-01

    To study the characteristics of patients with Propionibacterium acnes prosthetic valve endocarditis (PVE) who required surgery. A single-centre retrospective cohort study was conducted during a 7-year period. Patients with definite infective P. acnes endocarditis, according to the modified Duke criteria, were included. An extended culture protocol was applied. Information on medical health status, surgery, antibiotic treatment and mortality was obtained. Thirteen patients fulfilled the criteria for P. acnes endocarditis (0.53% of 2466 patients with valve replacement in a 7-year period). All patients were male and had a previous valve replacement. The health status of patients was poor at diagnosis of P. acnes PVE. Most patients (11 of 13, 85%) were admitted with signs of heart failure due to a significant paravalvular leak; 2 of 13 (15%) patients presented with septic emboli. Twelve patients needed redo surgery, whereas one could be treated with antibiotic therapy only. The time between the index surgery and presentation with P. acnes PVE varied between 5 and 135 months (median 26.5 months). Replacement and reconstruction of the dysfunctional valve and affected anatomical structures was mainly performed with a mechanical valve (n = 5, 42%) or a (bio-) Bentall prosthesis (n = 6, 50%). Antibiotic therapy consisted of penicillin with or without rifampicin for 6 weeks after surgery. The mortality in this series was low (n = 1, 8%) and no recurrent endocarditis was found during a median follow-up of 38 months. Propionibacterium acnes PVE is a rare complication after valve surgery. Redo surgery is often required. Treatment of the dysfunctional prosthetic aortic valve most often consists of root replacement, in combination with antibiotic therapy. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Sickle cell anemia and mitral valve replacement. Case report.

    PubMed

    Bomfim, V; Ribeiro, A; Gouvea, F; Pereira, J; Björk, V

    1989-01-01

    An 8-year-old black boy with sickle cell disease and severe hemolytic anemia crisis (95% hemoglobin S) also had mitral incompetence due to rheumatic valve disease. A 27 mm monostrut Björk-Shiley valve prosthesis was implanted after partial exchange transfusions had reduced the hemoglobin S to less than 40%. High-flow normothermic perfusion was used during extracorporeal circulation, with care taken to avoid hypoxia and acidosis. Postoperative recovery was uneventful.

  7. Multi-port valve assembly

    DOEpatents

    Guggenheim, S. Frederic

    1986-01-01

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.

  8. Early outcomes of transcatheter aortic valve replacement in patients with severe aortic stenosis: single center experience

    PubMed Central

    Bozkurt, Engin; Keleş, Telat; Durmaz, Tahir; Akçay, Murat; Ayhan, Hüseyin; Bayram, Nihal Akar; Aslan, Abdullah Nabi; Baştuğ, Serdal; Bilen, Emine

    2014-01-01

    Introduction Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. Aim Description early results of our single-center experience with balloon expandable aortic valve implantation. Material and methods Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. Results The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004). Conclusions We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an

  9. The Economics of Transcatheter Valve Interventions.

    PubMed

    Sud, Maneesh; Tam, Derrick Y; Wijeysundera, Harindra C

    2017-09-01

    A subset of patients who require correction of a stenotic or incompetent valve are deemed to be at excessive surgical risk, which precludes surgical repair or replacement. Transcatheter valve interventions are viable alternatives in these patients. However, these technologies are costly, and in the setting of a constrained Canadian health care budget, economic value is an important consideration to allow for fair allocation of scarce resources. Accordingly, we review the economic literature on transcatheter valve interventions, targeting a general audience. Our specific goals are highlighting how best to interpret these studies and discuss the implications of these technologies on the Canadian health care system. Transcatheter aortic valve replacement (TAVR) is a cost-effective alternative for inoperable patients who otherwise would receive medical therapy. When compared with surgical aortic valve replacement (SAVR), TAVR is associated with significant reductions in postprocedure hospital resource use, which offsets the substantially higher cost of the TAVR valve system relative to SAVR valves. Although cost-effectiveness estimates for TAVR in high-risk operable candidates vary widely across studies, based on contemporary data from the perspective of the Canadian health care system, TAVR is likely to provide economic value. Recent studies suggest that when compared with medical therapy for severe degenerative mitral regurgitation, the MitraClip (Abbott, Abbott Park, IL) may offer economic value in high-risk patients; however, in the absence of randomized controlled trials, this is speculative. Nonetheless, these transcatheter technologies represent a paradigm shift in the management of valvular disease; their dissemination will have substantial impact in cardiovascular care delivery. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. Aortic Root Replacement for Children With Loeys-Dietz Syndrome.

    PubMed

    Patel, Nishant D; Alejo, Diane; Crawford, Todd; Hibino, Narutoshi; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2017-05-01

    Loeys-Dietz syndrome (LDS) is an aggressive aortopathy with a proclivity for aortic aneurysm rupture and dissection at smaller diameters than other connective tissue disorders. We reviewed our surgical experience of children with LDS to validate our guidelines for prophylactic aortic root replacement (ARR). We reviewed all children (younger than 18 years) with a diagnosis of LDS who underwent ARR at our institution. The primary endpoint was mortality, and secondary endpoints included complications and the need for further interventions. Thirty-four children with LDS underwent ARR. Mean age at operation was 10 years, and 15 (44%) were female. Mean preoperative root diameter was 4 cm. Three children (9%) had composite ARR with a mechanical prosthesis, and 31 (91%) underwent valve-sparing ARR. Concomitant procedures included arch replacement in 2 (6%), aortic valve repair in 1 (3%), and patent foramen ovale closure in 16 (47%). There was no operative mortality. Two children (6%) required late replacement of the ascending aorta, 5 (15%) required arch replacement, 1 (3%) required mitral valve replacement, and 2 (6%) had coronary button aneurysms/pseudoaneurysms requiring repair. Three children required redo valve-sparing ARR after a Florida sleeve procedure, and 2 had progressive aortic insufficiency requiring aortic valve replacement after a valve-sparing procedure. There were 2 late deaths (6%). These data confirm the aggressive aortopathy of LDS. Valve-sparing ARR should be performed when feasible to avoid the risks of prostheses. Serial imaging of the arterial tree is critical, given the rate of subsequent intervention. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. How to Make a Heart Valve: From Embryonic Development to Bioengineering of Living Valve Substitutes

    PubMed Central

    MacGrogan, Donal; Luxán, Guillermo; Driessen-Mol, Anita; Bouten, Carlijn; Baaijens, Frank; de la Pompa, José Luis

    2014-01-01

    Cardiac valve disease is a significant cause of ill health and death worldwide, and valve replacement remains one of the most common cardiac interventions in high-income economies. Despite major advances in surgical treatment, long-term therapy remains inadequate because none of the current valve substitutes have the potential for remodeling, regeneration, and growth of native structures. Valve development is coordinated by a complex interplay of signaling pathways and environmental cues that cause disease when perturbed. Cardiac valves develop from endocardial cushions that become populated by valve precursor mesenchyme formed by an epithelial–mesenchymal transition (EMT). The mesenchymal precursors, subsequently, undergo directed growth, characterized by cellular compartmentalization and layering of a structured extracellular matrix (ECM). Knowledge gained from research into the development of cardiac valves is driving exploration into valve biomechanics and tissue engineering directed at creating novel valve substitutes endowed with native form and function. PMID:25368013

  12. Image-Based Patient-Specific Ventricle Models with Fluid-Structure Interaction for Cardiac Function Assessment and Surgical Design Optimization

    PubMed Central

    Tang, Dalin; Yang, Chun; Geva, Tal; del Nido, Pedro J.

    2010-01-01

    Recent advances in medical imaging technology and computational modeling techniques are making it possible that patient-specific computational ventricle models be constructed and used to test surgical hypotheses and replace empirical and often risky clinical experimentation to examine the efficiency and suitability of various reconstructive procedures in diseased hearts. In this paper, we provide a brief review on recent development in ventricle modeling and its potential application in surgical planning and management of tetralogy of Fallot (ToF) patients. Aspects of data acquisition, model selection and construction, tissue material properties, ventricle layer structure and tissue fiber orientations, pressure condition, model validation and virtual surgery procedures (changing patient-specific ventricle data and perform computer simulation) were reviewed. Results from a case study using patient-specific cardiac magnetic resonance (CMR) imaging and right/left ventricle and patch (RV/LV/Patch) combination model with fluid-structure interactions (FSI) were reported. The models were used to evaluate and optimize human pulmonary valve replacement/insertion (PVR) surgical procedure and patch design and test a surgical hypothesis that PVR with small patch and aggressive scar tissue trimming in PVR surgery may lead to improved recovery of RV function and reduced stress/strain conditions in the patch area. PMID:21344066

  13. Impact of Transcatheter Technology on Surgical Aortic Valve Replacement Volume, Outcomes, and Cost.

    PubMed

    Hawkins, Robert B; Downs, Emily A; Johnston, Lily E; Mehaffey, J Hunter; Fonner, Clifford E; Ghanta, Ravi K; Speir, Alan M; Rich, Jeffrey B; Quader, Mohammed A; Yarboro, Leora T; Ailawadi, Gorav

    2017-06-01

    Transcatheter aortic valve replacement (TAVR) represents a disruptive technology that is rapidly expanding in use. We evaluated the effect on surgical aortic valve replacement (SAVR) patient selection, outcomes, volume, and cost. A total of 11,565 patients who underwent SAVR, with or without coronary artery bypass grafting (2002 to 2015), were evaluated from the Virginia Cardiac Services Quality Initiative database. Patients were stratified by surgical era: pre-TAVR era (2002 to 2008, n = 5,113), early-TAVR era (2009 to 2011, n = 2,709), and commercial-TAVR era (2012 to 2015, n = 3,743). Patient characteristics, outcomes, and resource utilization were analyzed by univariate analyses. Throughout the study period, statewide SAVR volumes increased with median volumes of pre-TAVR: 722 cases/year, early-TAVR: 892 cases/year, and commercial-TAVR: 940 cases/year (p = 0.005). Implementation of TAVR was associated with declining Society of Thoracic Surgeons predicted risk of mortality among SAVR patients (3.7%, 2.6%, and 2.4%; p < 0.0001), despite increasing rates of comorbid disease. The mortality rate was lowest in the current commercial-TAVR era (3.9%, 4.3%, and 3.2%; p = 0.05), and major morbidity decreased throughout the time period (21.2%, 20.5%, and 15.2%; p < 0.0001). The lowest observed-to-expected ratios for both occurred in the commercial-TAVR era (0.9 and 0.9, respectively). Resource utilization increased generally, including total cost increases from $42,835 to $51,923 to $54,710 (p < 0.0001). At present, SAVR volumes have not been affected by the introduction of TAVR. The outcomes for SAVR continue to improve, potentially due to availability of transcatheter options for high-risk patients. Despite rising costs for SAVR, open approaches still provide a significant cost advantage over TAVR. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Prosthetic Aortic Valves: Challenges and Solutions

    PubMed Central

    Musumeci, Lucia; Jacques, Nicolas; Hego, Alexandre; Nchimi, Alain; Lancellotti, Patrizio; Oury, Cécile

    2018-01-01

    Aortic Valve Disease (AVD) is the most common Valvular Heart Disease (VHD), affecting millions of people worldwide. Severe AVD is treated in most cases with prosthetic aortic valve replacement, which involves the substitution of the native aortic valve with a prosthetic one. In this review we will discuss the different types of prosthetic aortic valves available for implantation and the challenges faced by patients, medical doctors, researchers and manufacturers, as well as the approaches that are taken to overcome them. PMID:29868612

  15. Transseptal antegrade transcatheter aortic valve replacement for patients with no other access approach - a contemporary experience.

    PubMed

    Cohen, Mauricio G; Singh, Vikas; Martinez, Claudia A; O'Neill, Brian P; Alfonso, Carlos E; Martinezclark, Pedro O; Heldman, Alan W; O'Neill, William W

    2013-11-15

    To assess the feasibility and outcomes in patients undergoing transvenous transseptal (TS) transcatheter aortic valve replacement (TAVR). TS approach for TAVR was abandoned in favor of retrograde transfemoral, transaortic, or transapical approaches. TS TAVR may still be warranted in patients for whom no other approach is feasible. Observational consecutive case series at a single center, to evaluate technical outcomes in inoperable patients with aortic stenosis who had contraindications for other approaches and who underwent TAVR via a transvenous TS antegrade approach using the Edwards-Sapien (ES) valve. Over a 4-month period, 9 patients underwent TS TAVR with 26 mm (n = 4) and 23 mm (n = 5) ES valves. Mean age was 84.5 ± 6.6 years and Society of Thoracic Surgeons predicted risk of mortality was 7.8 ± 2.8%. Specific contraindications for other access included iliofemoral arterial diameter <7 mm in 9 (100%), porcelain aorta in 6 (66%) patients, multiple (≥2) sternotomies in 2 (22%) patients, severe pulmonary disease in 3 (33%), extreme frailty in 1 (11%), spinal stenosis with impaired ability to rehabilitate postsurgery in 1 (11%) and apical left ventricular thrombus in 1 (11%) patient. Antegrade deployment of the ES prosthetic valve was technically feasible in 8 patients. Major bleeding occurred in 4 patients, two patients suffered acute kidney injury without need for dialysis and one patient required a permanent pacemaker. The median (25th, 75th percentiles) fluoroscopy time was 49 (34, 81) minutes and contrast volume was 150 (120, 225) ml. No patient had hemodynamically significant post-TAVR aortic insufficiency nor damage to the mitral valve. At 6 months follow-up, there were no cerebrovascular events or rehospitalizations and mean NYHA Class improved from 3.4 to 1.7. The antegrade TS approach to TAVR is a technically feasible option for "no-access" patients. Prospective assessment of the safety and efficacy of this approach in the current era warrants

  16. [Tricuspid valve regurgitation : Indications and operative techniques].

    PubMed

    Lange, R; Piazza, N; Günther, T

    2017-11-01

    Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.

  17. Late Outcomes of Transcatheter Aortic Valve Replacement in High-Risk Patients: The FRANCE-2 Registry.

    PubMed

    Gilard, Martine; Eltchaninoff, Hélène; Donzeau-Gouge, Patrick; Chevreul, Karine; Fajadet, Jean; Leprince, Pascal; Leguerrier, Alain; Lievre, Michel; Prat, Alain; Teiger, Emmanuel; Lefevre, Thierry; Tchetche, Didier; Carrié, Didier; Himbert, Dominique; Albat, Bernard; Cribier, Alain; Sudre, Arnaud; Blanchard, Didier; Rioufol, Gilles; Collet, Frederic; Houel, Remi; Dos Santos, Pierre; Meneveau, Nicolas; Ghostine, Said; Manigold, Thibaut; Guyon, Philippe; Grisoli, Dominique; Le Breton, Herve; Delpine, Stephane; Didier, Romain; Favereau, Xavier; Souteyrand, Geraud; Ohlmann, Patrick; Doisy, Vincent; Grollier, Gilles; Gommeaux, Antoine; Claudel, Jean-Philippe; Bourlon, Francois; Bertrand, Bernard; Laskar, Marc; Iung, Bernard

    2016-10-11

    Transcatheter aortic valve replacement (TAVR) has revolutionized management of high-risk patients with severe aortic stenosis. However, survival and the incidence of severe complications have been assessed in relatively small populations and/or with limited follow-up. This report details late clinical outcome and its determinants in the FRANCE-2 (FRench Aortic National CoreValve and Edwards) registry. The FRANCE-2 registry prospectively included all TAVRs performed in France. Follow-up was scheduled at 30 days, at 6 months, and annually from 1 to 5 years. Standardized VARC (Valve Academic Research Consortium) outcome definitions were used. A total of 4,201 patients were enrolled between January 2010 and January 2012 in 34 centers. Approaches were transarterial (transfemoral 73%, transapical 18%, subclavian 6%, and transaortic or transcarotid 3%) or, in 18% of patients, transapical. Median follow-up was 3.8 years. Vital status was available for 97.2% of patients at 3 years. The 3-year all-cause mortality was 42.0% and cardiovascular mortality was 17.5%. In a multivariate model, predictors of 3-year all-cause mortality were male sex (p < 0.001), low body mass index, (p < 0.001), atrial fibrillation (p < 0.001), dialysis (p < 0.001), New York Heart Association functional class III or IV (p < 0.001), higher logistic EuroSCORE (p < 0.001), transapical or subclavian approach (p < 0.001 for both vs. transfemoral approach), need for permanent pacemaker implantation (p = 0.02), and post-implant periprosthetic aortic regurgitation grade ≥2 of 4 (p < 0.001). Severe events according to VARC criteria occurred mainly during the first month and subsequently in <2% of patients/year. Mean gradient, valve area, and residual aortic regurgitation were stable during follow-up. The FRANCE-2 registry represents the largest database available on late results of TAVR. Late mortality is largely related to noncardiac causes. Incidence rates of severe events are low after the

  18. Poor performances of EuroSCORE and CARE score for prediction of perioperative mortality in octogenarians undergoing aortic valve replacement for aortic stenosis.

    PubMed

    Chhor, Vibol; Merceron, Sybille; Ricome, Sylvie; Baron, Gabriel; Daoud, Omar; Dilly, Marie-Pierre; Aubier, Benjamin; Provenchere, Sophie; Philip, Ivan

    2010-08-01

    Although results of cardiac surgery are improving, octogenarians have a higher procedure-related mortality and more complications with increased length of stay in ICU. Consequently, careful evaluation of perioperative risk seems necessary. The aims of our study were to assess and compare the performances of EuroSCORE and CARE score in the prediction of perioperative mortality among octogenarians undergoing aortic valve replacement for aortic stenosis and to compare these predictive performances with those obtained in younger patients. This retrospective study included all consecutive patients undergoing cardiac surgery in our institution between November 2005 and December 2007. For each patient, risk assessment for mortality was performed using logistic EuroSCORE, additive EuroSCORE and CARE score. The main outcome measure was early postoperative mortality. Predictive performances of these scores were assessed by calibration and discrimination using goodness-of-fit test and area under the receiver operating characteristic curve, respectively. During this 2-year period, we studied 2117 patients, among whom 134/211 octogenarians and 335/1906 nonoctogenarians underwent an aortic valve replacement for aortic stenosis. When considering patients with aortic stenosis, discrimination was poor in octogenarians and the difference from nonoctogenarians was significant for each score (0.58, 0.59 and 0.56 vs. 0.82, 0.81 and 0.77 for additive EuroSCORE, logistic EuroSCORE and CARE score in octogenarians and nonoctogenarians, respectively, P < 0.05). Moreover, in the whole cohort, logistic EuroSCORE significantly overestimated mortality among octogenarians. Predictive performances of these scores are poor in octogenarians undergoing cardiac surgery, especially aortic valve replacement. Risk assessment and therapeutic decisions in octogenarians should not be made with these scoring systems alone.

  19. Using Time-Driven Activity-Based Costing as a Key Component of the Value Platform: A Pilot Analysis of Colonoscopy, Aortic Valve Replacement and Carpal Tunnel Release Procedures.

    PubMed

    Martin, Jacob A; Mayhew, Christopher R; Morris, Amanda J; Bader, Angela M; Tsai, Mitchell H; Urman, Richard D

    2018-04-01

    Time-driven activity-based costing (TDABC) is a methodology that calculates the costs of healthcare resources consumed as a patient moves along a care process. Limited data exist on the application of TDABC from the perspective of an anesthesia provider. We describe the use of TDABC, a bottom-up costing strategy and financial outcomes for three different medical-surgical procedures. In each case, a multi-disciplinary team created process maps describing the care delivery cycle for a patient encounter using the TDABC methodology. Each step in a process map delineated an activity required for delivery of patient care. The resources (personnel, equipment and supplies) associated with each step were identified. A per minute cost for each resource expended was generated, known as the capacity cost rate, and multiplied by its time requirement. The total cost for an episode of care was obtained by adding the cost of each individual resource consumed as the patient moved along a clinical pathway. We built process maps for colonoscopy in the gastroenterology suite, calculated costs of an aortic valve replacement by comparing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR) techniques, and determined the cost of carpal tunnel release in an operating room versus an ambulatory procedure room. TDABC is central to the value-based healthcare platform. Application of TDABC provides a framework to identify process improvements for health care delivery. The first case demonstrates cost-savings and improved wait times by shifting some of the colonoscopies scheduled with an anesthesiologist from the main hospital to the ambulatory facility. In the second case, we show that the deployment of an aortic valve via the transcatheter route front loads the costs compared to traditional, surgical replacement. The last case demonstrates significant cost savings to the healthcare system associated with re-organization of staff required to execute a

  20. Pediatric Tubular Pulmonary Heart Valve from Decellularized Engineered Tissue Tubes

    PubMed Central

    Reimer, Jay M.; Syedain, Zeeshan H.; Haynie, Bee H.T.; Tranquillo, Robert T.

    2015-01-01

    Pediatric patients account for a small portion of the heart valve replacements performed, but a pediatric pulmonary valve replacement with growth potential remains an unmet clinical need. Herein we report the first tubular heart valve made from two decellularized, engineered tissue tubes attached with absorbable sutures, which can meet this need, in principle. Engineered tissue tubes were fabricated by allowing ovine dermal fibroblasts to replace a sacrificial fibrin gel with an aligned, cell-produced collagenous matrix, which was subsequently decellularized. Previously, these engineered tubes became extensively recellularized following implantation into the sheep femoral artery. Thus, a tubular valve made from these tubes may be amenable to recellularization and, ideally, somatic growth. The suture line pattern generated three equi-spaced “leaflets” in the inner tube, which collapsed inward when exposed to back pressure, per tubular valve design. Valve testing was performed in a pulse duplicator system equipped with a secondary flow loop to allow for root distention. All tissue-engineered valves exhibited full leaflet opening and closing, minimal regurgitation (< 5%), and low systolic pressure gradients (< 2.5 mmHg) under pulmonary conditions. Valve performance was maintained under various trans-root pressure gradients and no tissue damage was evident after 2 million cycles of fatigue testing. PMID:26036175

  1. Complete versus partial preservation of mitral valve apparatus during mitral valve replacement: meta-analysis and meta-regression of 1535 patients.

    PubMed

    Sá, Michel Pompeu Barros De Oliveira; Escobar, Rodrigo Renda; Ferraz, Paulo Ernando; Vasconcelos, Frederico Pires; Lima, Ricardo Carvalho

    2013-11-01

    To determine if there is any real difference between complete preservation (CP) and partial preservation (PP) of the mitral valve apparatus during mitral valve replacement (MVR) in terms of hard outcomes. MEDLINE, EMBASE, CENTRAL/CCTR, SciELO, LILACS, Google Scholar and reference lists of relevant articles were searched for clinical studies that compared outcomes [30-day mortality, postoperative low cardiac output syndrome (LCOS), 5-year mortality or left ventricle ejection fraction (LVEF) before and after surgery] between MVR-CP vs MVR-PP during MVR until July 2012. The principal summary measures were odds ratios (ORs) with 95% confidence interval (CI)--for categorical variables (30-day mortality, postoperative LCOS, 5-year mortality); difference means and standard error (SE)--for continuous variables (LVEF before and after surgery) and P values (that will be considered statistically significant when <0.05). The ORs were combined across studies using DerSimonian-Laird random effects weighted model. The same procedure was executed for continuous variables, taking into consideration the difference in means. Eight studies (2 randomized and 6 non-randomized) were identified and included a total of 1535 patients (597 for MVR-CP and 938 for MVR-PP). There was no significant difference between MVR-CP or MVR-PP groups in the risk for 30-day mortality (OR 0.870; 95% CI 0.50-1.52; P = 0.63) or postoperative LCOS (OR 0.35; 95% CI 0.11-1.08 and P = 0.07) or 5-year mortality (OR 0.70; 95% CI 0.43-1.14; P = 0.15). Taking into consideration LVEF, neither MVR-CP nor MVR-CP demonstrated a statistically significant improvement in LVEF before and after surgery, and both strategies were not different from each other. No publication bias was observed. We found evidence that argues against any superiority between both techniques of preservation (complete or partial) of mitral valve apparatus during MVR.

  2. A new paradigm for obtaining marketing approval for pediatric-sized prosthetic heart valves.

    PubMed

    Yoganathan, Ajit P; Fogel, Mark; Gamble, Susan; Morton, Michael; Schmidt, Paul; Secunda, Jeff; Vidmar, Sara; Del Nido, Pedro

    2013-10-01

    Congenital heart valve disease is one of the most common abnormalities in children. There are limited technological solutions available for treating children with congenital heart valve diseases. The aim of this study is to provide the details of the consensus reached in terms of pediatric definitions, design approach, in vitro testing, and clinical trials, which may be used as guidance for developing prosthetic heart valves for the pediatric indication. In stark contrast to the various designs of adult-sized replacement valves available in the market, there are no Food and Drug Administration (FDA)-approved prosthetic heart valves available for use in the pediatric population. There is a pressing need for FDA-approved pediatric valve devices in the United States. The pediatric patient population has been typically excluded from replacement heart valve trials for several reasons. In January 2010, heart valve manufacturers and pediatric clinicians collaborated with academicians and FDA staff in a workshop to suggest ways to successfully evaluate pediatric prosthetic valves and conduct pediatric clinical trials to provide acceptable heart valve replacement options for this patient population. Recommendations, derived from ISO 5840:2005 and the 2010 FDA Draft Replacement Heart Valve Guidance, are provided for hydrodynamic, durability, and fatigue testing. The article specifically addresses in vitro and premarket and postmarket approval clinical studies that should be considered by a heart valve manufacturer for obtaining regulatory approval of pediatric sizes of prosthetic heart valve designs that are already approved for adult clinical use. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  3. Changes in Mitral Annular Geometry after Aortic Valve Replacement: A Three-Dimensional Transesophageal Echocardiographic Study

    PubMed Central

    Mahmood, Feroze; Warraich, Haider J.; Gorman, Joseph H.; Gorman, Robert C.; Chen, Tzong-Huei; Panzica, Peter; Maslow, Andrew; Khabbaz, Kamal

    2014-01-01

    Background and aim of the study Intraoperative real-time three-dimensional transesophageal echocardiography (RT-3D TEE) was used to examine the geometric changes that occur in the mitral annulus immediately after aortic valve replacement (AVR). Methods A total of 35 patients undergoing elective surgical AVR under cardiopulmonary bypass was enrolled in the study. Intraoperative RT-3D TEE was used prospectively to acquire volumetric echocardiographic datasets immediately before and after AVR. The 3D echocardiographic data were analyzed offline using TomTec® Mitral Valve Assessment software to assess changes in specific mitral annular geometric parameters. Results Datasets were successfully acquired and analyzed for all patients. A significant reduction was noted in the mitral annular area (-16.3%, p <0.001), circumference (-8.9% p <0.001) and the anteroposterior (-6.3%, p = 0.019) and anterolateral-posteromedial (-10.5%, p <0.001) diameters. A greater reduction was noted in the anterior annulus length compared to the posterior annulus length (10.5% versus 62%, p <0.05) after AVR. No significant change was seen in the non-planarity angle, coaptation depth, and closure line length. During the period of data acquisition before and after AVR, no significant change was noted in the central venous pressure or left ventricular end-diastolic diameter. Conclusion The mitral annulus undergoes significant geometric changes immediately after AVR Notably, a 16.3% reduction was observed in the mitral annular area. The anterior annulus underwent a greater reduction in length compared to the posterior annulus, which suggested the existence of a mechanical compression by the prosthetic valve. PMID:23409347

  4. Etiology and Risk Factors for Cerebral Infarct after Surgical Aortic Valve Replacement

    PubMed Central

    Massaro, Allie; Messé, Steven R.; Acker, Michael A.; Kasner, Scott E.; Torres, Jose; Fanning, Molly; Giovannetti, Tania; Ratcliffe, Sarah J.; Bilello, Michel; Szeto, Wilson Y.; Bavaria, Joseph E.; Mohler, Emile R.; Floyd, Thomas F.

    2016-01-01

    Background and Purpose Stroke is a potentially devastating complication of cardiac surgery. Identifying predictors of radiographic infarct may lead to improved stroke prevention for surgical patients. Methods We reviewed 129 post-operative brain MRIs from a prospective study of patients undergoing surgical aortic valve replacement (AVR). Acute infarcts were classified as watershed or embolic using pre-specified criteria. Results Acute infarct on MRI was seen in 79 of 129 patients (61%), interrater reliability for stroke etiology was high (κ =0.93). Embolic infarcts only were identified in 60 (46%), watershed only in 2 (2%), and both in 17 (13%). In multivariable logistic regression, embolic infarct was associated with aortic arch atheroma (OR=3.4, 95%CI 1.0-12.0, p=0.055), old subcortical infarcts (OR= 5.5, 95%CI 1.1-26.6, p=0.04), no history of PTCA or CABG (OR=4.0, 95%CI 1.2-13.7, p=0.03), and higher aortic valve gradient (OR=1.3 per 5mmHg, 95%CI 1.09-1.6, p=0.004). Watershed infarct was associated with internal carotid artery stenosis ≥70% (OR=11.7, 95%CI 1.8-76.8, p=0.01) and increased left ventricular ejection fraction (OR=1.6 per 5% increase, 95%CI 1.08-2.4, p=0.02). Conclusions The principal mechanism of acute cerebral infarction after AVR is embolism. There are distinct factors associated with watershed and embolic infarct, some of which may be modifiable. PMID:27382005

  5. Field Experience with Lock Culvert Valves

    DTIC Science & Technology

    2013-12-01

    factors pertaining to valves such as the hoist loads, cavitation parameter, and effects of venting. To reduce the surge in the navigation channel...2 min 15 sec, filling-and-emptying valve opening time) ensures that adequate air is drawn into the culvert to cushion the cavitation implosions...shape can have adverse hydrodynamic loading consequences. The USACE, Mobile District (SAM) is in the process of designing replacement valves that are

  6. Quality and Safety in Health Care, Part XXXII: Additional Outcome Predictors for Transcatheter Aortic Valve Replacement.

    PubMed

    Harolds, Jay A

    2018-02-01

    Mortality 12 months after a transcatheter aortic valve replacement (TAVR) is partly due to a number of reasons in addition to the usual preprocedural medical patient risk factors. In patients who need a permanent pacemaker placed after the procedure, the mortality risk goes up. The death rate following a TAVR varies considerably at different institutions, and the past death rate of TAVR patients at an institution is predictive of the mortality rate of new patients having this procedure. In addition, the quality of life of the individual before the procedure is predictive of the 12-month mortality outcome after the TAVR is done.

  7. Tricuspid valve endocarditis

    PubMed Central

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  8. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    PubMed

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  9. Contemporary experience with surgical treatment of aortic valve disease in children.

    PubMed

    Khan, Muhammad S; Samayoa, Andres X; Chen, Diane W; Petit, Christopher J; Fraser, Charles D

    2013-09-01

    Surgical treatment of aortic valve (AoV) disease in childhood involves complex decisions particularly in very small patients. There is no consensus regarding the optimum surgical option. The objective of this review was to analyze a contemporary experience of AoV surgery in a large children's hospital. A retrospective review of children (aged ≤ 18 years) undergoing AoV repair or replacement from June 1995 to December 2011 was carried out. A total of 285 AoV operations (97 repairs, 188 replacements) were performed on 241 patients. Hospital survival for repair was 98% and for replacements was 97%. At follow-up of repairs, there were 16 (17%) reoperations and 3 (3%) late deaths. Follow-up of AoV replacements demonstrated 31 (16%) reoperations (homograft 27, autograft 3, mechanical 1) and 8 (4%) late deaths (homograft 5, autograft 2, mechanical 1). Freedom from reintervention or death (FRD) was found to be lower in repairs for infants (P = .048) and truncal valves (P < .05). For AoV replacements, infants and patients who had concomitant CHD or homografts (P < .0001) had lower FRD. Cox regression analysis for AoV replacements identified infants and homograft root replacements at a higher risk for death/reoperation. AoV repairs and replacements were generally found to be associated with low death and reoperation rates at long-term follow-up. Infants had a lower freedom from reintervention or death after either an AoV repair or replacement, although truncal valve repairs and AoV replacement in patients with concomitant CHD were associated with lower valve survival. Among the valve options, homograft root replacement had a higher risk of death/reoperation and lowest freedom from reintervention or death. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. Impact of wait times on the effectiveness of transcatheter aortic valve replacement in severe aortic valve disease: a discrete event simulation model.

    PubMed

    Wijeysundera, Harindra C; Wong, William W L; Bennell, Maria C; Fremes, Stephen E; Radhakrishnan, Sam; Peterson, Mark; Ko, Dennis T

    2014-10-01

    There is increasing demand for transcatheter aortic valve replacement (TAVR) as the primary treatment option for patients with severe aortic stenosis who are high-risk surgical candidates or inoperable. We used mathematical simulation models to estimate the hypothetical effectiveness of TAVR with increasing wait times. We applied discrete event modelling, using data from the Placement of Aortic Transcatheter Valves (PARTNER) trials. We compared TAVR with medical therapy in the inoperable cohort, and compared TAVR to conventional aortic valve surgery in the high-risk cohort. One-year mortality and wait-time deaths were calculated in different scenarios by varying TAVR wait times from 10 days to 180 days, while maintaining a constant wait time for surgery at a mean of 15.6 days. In the inoperable cohort, the 1-year mortality for medical therapy was 50%. When the TAVR wait time was 10 days, the TAVR wait-time mortality was 1.9% with a 1-year mortality of 31.5%. TAVR wait-time deaths increased to 28.9% with a 180-day wait, with a 1-year mortality of 41.4%. In the high-risk cohort, the wait-time deaths and 1-year mortality for the surgical patients were 2.5% and 27%, respectively. The TAVR wait-time deaths increased from 2.2% with a 10-day wait to 22.4% with a 180-day wait, and a corresponding increase in 1-year mortality from 24.5% to 32.6%. Mortality with TAVR exceeded surgery when TAVR wait times exceeded 60 days. Modest increases in TAVR wait times have a substantial effect on the effectiveness of TAVR in inoperable patients and high-risk surgical candidates. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures.

    PubMed

    Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker

    2018-02-01

    In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.

  12. Use of a novel drainage flow servo-controlled CPB for mitral valve replacement in a Jehovah's Witness.

    PubMed

    Niimi, Yoshinari; Murata, Seiichiro; Mitou, Yumi; Ohno, Yusuke

    2018-03-01

    We developed a novel open cardiopulmonary bypass (CPB) system, a drainage flow servo-controlled CPB system (DS-CPB), in which rotational speed of the main roller pump is servo-controlled to generate the same amount of flow as the systemic venous drainage. It was designed to safely decrease the priming volume while maintaining a constant reservoir level, even during fluctuations of the drainage flow. We report a successful use of a novel DS-CPB system in an elderly Jehovah's Witness patient with dehydration who underwent mitral valve replacement.

  13. Aortic Valve Replacement for Moderate Aortic Stenosis with Severe Calcification and Left Ventricualr Dysfunction-A Case Report and Review of the Literature.

    PubMed

    Narang, Nikhil; Lang, Roberto M; Liarski, Vladimir M; Jeevanandam, Valluvan; Hofmann Bowman, Marion A

    2017-01-01

    A 55-year-old man with a history of erosive, seropositive rheumatoid arthritis (RA), and interstitial lung disease presented with shortness of breath. Echocardiography showed new-onset severe left ventricular (LV) dysfunction with an ejection fraction (EF) of 15% and moderately increased mean aortic valve gradient of 20 mmHg in a trileaflet aortic valve with severe sclero-calcific degeneration. Coronary angiography revealed no significant obstructive coronary disease. Invasive hemodynamic studies and dobutamine stress echocardiography were consistent with moderate aortic stenosis. Guideline directed medical therapy for heart failure with reduced EF was initiated; however, diuretics and neurohormonal blockade (beta-blocker and angiotensin receptor blocker) provided minimal improvement, and the patient remained functionally limited. Of interest, echocardiography performed 1 year prior to his presentation showed normal LV EF and mild aortic leaflet calcification with moderate stenosis, suggesting a rapid progressing of calcific aortic valve disease. Subsequently, the patient underwent surgical aortic valve replacement and demonstrated excellent postsurgical recovery of LV EF (55%). Calcific aortic valve disease is commonly associated with aging, bicuspid aortic valve, and chronic kidney disease. Pathophysiological mechanism for valvular calcification is incompletely understood but include osteogenic transformation of valvular interstitial cells mediated by local and systemic inflammatory processes. Several rheumatologic diseases including RA are associated with premature atherosclerosis and arterial calcification, and we speculated a similar role of RA accelerating calcific aortic valve disease. We present a case of accelerated aortic valve calcification with (only) moderate stenosis, complicated by a rapid decline in LV systolic performance. Guidelines for AVR in moderate stenosis without concomitant cardiac surgery are not well established, although it should be

  14. Balloon aortic valvuloplasty to improve candidacy of patients evaluated for transcatheter aortic valve replacement.

    PubMed

    Arsalan, Mani; Khan, Samir; Golman, Jake; Szerlip, Molly; Mahoney, Cecile; Herbert, Morley; Brown, David; Mack, Michael; Holper, Elizabeth M

    2018-02-01

    Evaluate the role of balloon aortic valvuloplasty (BAV) in improving candidacy of patients for transcatheter aortic valve replacement (TAVR). Patients who are not candidates for TAVR may undergo BAV to improve functional and clinical status. 117 inoperable or high-risk patients with critical aortic stenosis underwent BAV as a bridge-to-decision for TAVR. Frailty measures including gait speed, serum albumin, hand grip, activities of daily living (ADL); and NYHA functional class before and after BAV were compared. Mean age was 81.6 ± 8.5 years and the mean Society of Thoracic Surgeons predicted risk of mortality was 9.57 ± 5.51, with 19/117 (16.2%) patients non-ambulatory. There was no significant change in mean GS post-BAV, but all non-ambulatory patients completed GS testing at follow-up. Albumin and hand grip did not change after BAV, but there was a significant improvement in mean ADL score (4.85 ± 1.41 baseline to 5.20 ± 1.17, P = 0.021). The number of patients with Class IV congestive heart failure (CHF) was significantly lower post BAV (71/117 [60.7%] baseline versus 18/117 [15.4%], P = 0.008). 78/117 (66.7%) of patients were referred to definitive valve therapy after BAV. When evaluating frailty measures post BAV, we saw no significant improvement in mean GS, however, we observed a significant improvement in non-ambulatory patients and ADL scores. We also describe improved Class IV CHF symptoms. With this improved health status, the majority of patients underwent subsequent valve therapy, demonstrating that BAV may improve candidacy of patients for TAVR. © 2017, Wiley Periodicals, Inc.

  15. [Pannus Formation Two Years after Bioprosthetic Aortic Valve Implantation;Report of a Case].

    PubMed

    Ono, Kimiyo; Kuroda, Hiroaki

    2015-08-01

    We report a case of early deterioration of the bioprosthetic aortic valve 23 months postoperatively. A 77-year-old man who had undergone aortic valve replacement with a 23-mm Epic valve( St. Jude Medical [SJM])presented to us after a syncopal episode. Echocardiography revealed severe aortic stenosis, and redo aortic valve replacement with a 21-mm SJM mechanical valve was performed. All 3 cusps of the tissue valve were thickened by fibrous pannus overgrowth. Neither calcification nor invasion of inflammatory cells was observed. The cause of pannus formation at such an early stage after implantation remains unknown.

  16. Bioprinting a cardiac valve.

    PubMed

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Percutaneous Pulmonary Valve Placement

    PubMed Central

    Prieto, Lourdes R.

    2015-01-01

    Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629

  18. Safety and Efficacy of Transcatheter Aortic Valve Replacement in the Treatment of Pure Aortic Regurgitation in Native Valves and Failing Surgical Bioprostheses: Results From an International Registry Study.

    PubMed

    Sawaya, Fadi J; Deutsch, Marcus-André; Seiffert, Moritz; Yoon, Sung-Han; Codner, Pablo; Wickramarachchi, Upul; Latib, Azeem; Petronio, A Sonia; Rodés-Cabau, Josep; Taramasso, Maurizio; Spaziano, Marco; Bosmans, Johan; Biasco, Luigi; Mylotte, Darren; Savontaus, Mikko; Gheeraert, Peter; Chan, Jason; Jørgensen, Troels H; Sievert, Horst; Mocetti, Marco; Lefèvre, Thierry; Maisano, Francesco; Mangieri, Antonio; Hildick-Smith, David; Kornowski, Ran; Makkar, Raj; Bleiziffer, Sabine; Søndergaard, Lars; De Backer, Ole

    2017-05-22

    The aim of this study was to evaluate the use of transcatheter heart valves (THV) for the treatment of noncalcific pure native aortic valve regurgitation (NAVR) and failing bioprosthetic surgical heart valves (SHVs) with pure severe aortic regurgitation (AR). Limited data are available about the "off-label" use of transcatheter aortic valve replacement (TAVR) to treat pure severe AR. The study population consisted of patients with pure severe AR treated by TAVR at 18 different centers. Study endpoints were device success, early safety, and clinical efficacy at 30 days, as defined by Valve Academic Research Consortium 2 criteria. A total of 146 patients were included, 78 patients in the NAVR group and 68 patients in the failing SHV group. In the NAVR group, device success, early safety, and clinical efficacy were 72%, 66%, and 61%, respectively. Device success and clinical efficacy were significantly better with newer generation THVs compared with old-generation THVs (85% vs. 54% and 75% vs. 46%, respectively, p < 0.05); this was mainly due to less second THV implantations and a lower rate of moderate to severe paravalvular regurgitation (10% vs. 24% and 3% vs. 27%, respectively). Independent predictors of 30-day mortality were body mass index <20 kg/m 2 , STS surgical risk score >8%, major vascular or access complication, and moderate to severe AR. In the failing SHV group, device success, early safety, and clinical efficacy were 71%, 90%, and 77%, respectively. TAVR for pure NAVR remains a challenging condition, with old-generation THVs being associated with THV embolization and migration and significant paravalvular regurgitation. Newer generation THVs show more promising outcomes. For those patients with severe AR due to failing SHVs, TAVR is a valuable therapeutic option. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Beyond adding years to life: health-related quality-of-life and functional outcomes in patients with severe aortic valve stenosis at high surgical risk undergoing transcatheter aortic valve replacement.

    PubMed

    Deutsch, Marcus-Andre; Bleiziffer, Sabine; Elhmidi, Yacine; Piazza, Nicolo; Voss, Bernhard; Lange, Ruediger; Krane, Markus

    2013-11-01

    Aortic valve stenosis (AVS) is the most frequent acquired valvular heart disease in western industrialized countries and its prevalence considerably increases with age. Once becoming symptomatic severe AVS has a very poor prognosis. Progressive and rapid symptom deterioration leads to an impairment of functional status and compromised healthrelated quality-of-life (HrQoL) simultaneously. Until recently, surgical aortic valve replacement (SAVR) has been the only effective treatment option for improving symptoms and prolonging survival. Transcatheter aortic valve replacement (TAVR) emerged as an alternative treatment modality for those patients with severe symptomatic AVS in whom the risk for SAVR is considered prohibitive or too high. TAVR has gained clinical acceptance with almost startling rapidity and has even quickly become the standard of care for the treatment of appropriately selected individuals with inoperable AVS during recent years. Typically, patients currently referred for and treated by TAVR are elderly with a concomitant variable spectrum of multiple comorbidities, disabilities and limited life expectancy. Beyond mortality and morbidity, the assessment of HrQoL is of paramount importance not only to guide patient-centered clinical decision-making but also to judge this new treatment modality. As per current evidence, TAVR significantly improves HrQoL in high-surgical risk patients with severe AVS with sustained effects up to two years when compared with optimal medical care and demonstrates comparable benefits relative to SAVR. Along with a provision of a detailed overview of the current literature regarding functional and HrQoL outcomes in patients undergoing TAVR, this review article addresses specific considerations of the HrQoL aspect in the elderly patient and finally outlines the implications of HrQoL outcomes for medico-economic deliberations.

  20. Percutaneous coronary intervention in patients with severe aortic stenosis: implications for transcatheter aortic valve replacement.

    PubMed

    Goel, Sachin S; Agarwal, Shikhar; Tuzcu, E Murat; Ellis, Stephen G; Svensson, Lars G; Zaman, Tarique; Bajaj, Navkaranbir; Joseph, Lee; Patel, Neil S; Aksoy, Olcay; Stewart, William J; Griffin, Brian P; Kapadia, Samir R

    2012-02-28

    With the availability of transcatheter aortic valve replacement, management of coronary artery disease in patients with severe aortic stenosis (AS) is posing challenges. Outcomes of percutaneous coronary intervention (PCI) in patients with severe AS and coronary artery disease remain unknown. We sought to compare the short-term outcomes of PCI in patients with and without AS. From our PCI database, we identified 254 patients with severe AS who underwent PCI between 1998 and 2008. Using propensity matching, we found 508 patients without AS who underwent PCI in the same period. The primary end point of 30-day mortality after PCI was similar in patients with and without severe AS (4.3% [11 of 254] versus 4.7% [24 of 508]; hazard ratio, 0.93; 95% confidence interval, 0.51-1.69; P=0.2). Patients with low ejection fraction (≤30%) and severe AS had a higher 30-day post-PCI mortality compared with those with an ejection fraction >30% (5.4% [7 of 45] versus 1.2% [4 of 209]; P<0.001). In addition, AS patients with high Society of Thoracic Surgeons score (≥10) had a higher 30-day post-PCI mortality than those with a Society of Thoracic Surgeons score <10 (10.4% [10 of 96] versus 0%; P<0.001). PCI can be performed in patients with severe symptomatic AS and coronary artery disease without an increased risk of short-term mortality compared with propensity-matched patients without AS. Patients with ejection fraction ≤30% and Society of Thoracic Surgeons score ≥10% are at a highest risk of 30-day mortality after PCI. This finding has significant implications in the management of severe coronary artery disease in high-risk severe symptomatic AS patients being considered for transcatheter aortic valve replacement.

  1. Aortic valve surgery of the 21st century: sutureless AVR versus TAVI.

    PubMed

    Costache, Victor S; Moldovan, Horatiu; Arsenescu, Catalina; Costache, Andreea

    2018-04-01

    Surgical aortic valve replacement (sAVR) has been a safe, effective and time-proven technique and is still the standard of care all over the world for aortic valve treatment. The vast majority of centers perform this procedure by doing a median sternotomy with several disadvantages. While many others specialties went minimally invasive decades ago, in cardiovascular field transcatheter valve implantation was the first minimally invasive valvular procedure that gained rapid worldwide acceptance. Transcatheter valve replacement (TAVR) is now marketed as a procedure that should be performed under local anesthesia, by an interventional cardiologist via trans femoral route with no other healthcare professional invited to the patient selection or case planning. An increasing number of surgeons are promoting minimally invasive aortic valve replacement, which is gaining grounds, especially with the help of the new sutureless valve technology. With these two new technologies emerging, legitimate questions arise and need to be answered - which has the longest durability, lower complication rate and lower overall mortality.

  2. Transapical Mitral Valve Implantation for Native Mitral Valve Stenosis Using a Balloon-Expandable Prosthesis.

    PubMed

    Kiefer, Philipp; Noack, Thilo; Seeburger, Joerg; Hoyer, Alexandro; Linke, Axel; Mangner, Norman; Lehmkuhl, Lukas; Mohr, Friedrich Wilhelm; Holzhey, David

    2017-12-01

    Transcatheter mitral valve implantation (TMVI) is still in its infancy and is mainly limited to valve-in-valve or valve-in-ring implantations. We present the early experience with TMVI for severe calcified native MV stenosis. Between January 2014 and June 2015, 6 of 11 patients screened (mean age, 77.4 ± 6.3 years; 66% men) with severe native mitral valve (MV) stenosis (mean gradient [Pmean], 11.1 ± 2.1 mm Hg; mean effective orifice area [EOA], 0.9 ± 0.12 cm 2 ) underwent transcatheter MV replacement at our institution as a bailout procedure. Conventional surgical procedures were denied in all patients because of severe annular calcification and extensive comorbidities (mean logistic EuroScore, 31.4% ± 8.3%). The Edwards SAPIEN 3 (29 mm) (Edwards Lifesciences, Irvine, CA) was used in all cases. Procedural access was transapical in 5 cases and concomitant to aortic valve replacement through the left atrium through a sternotomy in 1 case. Initial implantation was successful in 100% of the cases. Because of early migration, 1 patient needed a valve-in-valve procedure. Postoperative echocardiography showed no residual mitral regurgitation in 4 cases (66%) and mild regurgitation in 2 cases (34%). Mean gradients were reduced to 4.2 ± 0.6 mm Hg (mean EOA, 2.8 ± 0.4 cm 2) . No patient had a stroke during hospitalization, and 30-day mortality was seen in 1 patient (17%) resulting from pneumonia. TMV implantation using the SAPIEN 3 aortic prosthesis in patients with heavy annular calcification is feasible and represents a reasonable bailout option for inoperable patients. However, several limitations need to be considered in this special patient population. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Liquid-fuel valve with precise throttling control

    NASA Technical Reports Server (NTRS)

    Mcdougal, A. R.; Porter, R. N.; Riebling, R. W.

    1971-01-01

    Prototype liquid-fuel valve performs on-off and throttling functions in vacuum without component cold-welding or excessive leakage. Valve design enables simple and rapid disassembly and parts replacement and operates with short working stroke, providing maximum throttling sensitivity commensurate with good control.

  4. The mechanobiology of mitral valve function, degeneration, and repair

    PubMed Central

    Richards, Jennifer M.; Farrar, Emily J.; Kornreich, Bruce G.; Moïse, N. Sydney; Butcher, Jonathan T.

    2013-01-01

    In degenerative valve disease, the highly organized mitral valve leaflet matrix stratification is progressively destroyed and replaced with proteoglycan rich, mechanically inadequate tissue. This is driven by the actions of originally quiescent valve interstitial cells that become active contractile and migratory myofibroblasts. While treatment for myxomatous mitral valve disease in humans ranges from repair to total replacement, therapies in dogs focus on treating the consequences of the resulting mitral regurgitation. The fundamental gap in our understanding is how the resident valve cells respond to altered mechanical signals to drive tissue remodeling. Despite the pathological similarities and high clinical occurrence, surprisingly little mechanistic insight has been gleaned from the dog. This review presents what is known about mitral valve mechanobiology from clinical, in vivo, and in vitro data. There are a number of experimental strategies already available to pursue this significant opportunity, but success requires the collaboration between veterinary clinicians, scientists, and engineers. PMID:22366572

  5. Natural history of the ascending aorta after aortic valve replacement: risk factor analysis for late aortic complications after aortic valve replacement.

    PubMed

    Tsutsumi, Koji; Hashizume, Kenichi; Inoue, Yoshito

    2016-05-01

    The purpose of this study was to clarify the natural history of the ascending aorta and to identify risk factors for late ascending aortic events after first isolated aortic valve replacement (AVR). A total of 287 patients undergoing AVR were enrolled. The patients were categorized into two groups based on the diameter of the ascending aorta at the time of AVR, as determined by computed tomography: Group A (n = 233) was defined as an ascending aortic diameter <40 mm, and Group B (n = 54) was defined as an ascending aortic diameter ≥40 mm. The mean follow-up period was 7.6 years. The baseline diameter of the ascending aorta was 31.4 ± 4.8 mm in Group A and 44.7 ± 4.2 mm in Group B. These values increased to 35.9 ± 7.4 mm in Group A and 50.1 ± 7.3 mm in Group B during the follow-up period (P < 0.001). Ten patients had acute type A aortic dissection (Group A: 1 patient vs. Group B: 9 patients; P < 0.001), and three patients had enlargement of the ascending aorta to ≥55 mm in diameter (Group A: 1 patient vs. Group B: 2 patients). Multivariate analysis revealed that the baseline ascending aortic diameter was the only significant risk factor for developing late ascending aortic events (P < 0.001). AVR alone may not prevent further enlargement of the ascending aorta. An ascending aorta ≥40 mm in diameter at the time of AVR increased the risk of late ascending aortic events.

  6. Valve exploiting the principle of a side channel turbine

    NASA Astrophysics Data System (ADS)

    Jandourek, Pavel; Pochylý, František; Haban, Vladimír

    2017-04-01

    The presented article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Pressure reducing valves are a source of high hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the reducing valve and the side channel turbine. The basis for the design is the loss characteristics of the pressure reducing valve. Thereby create a new kind of turbine valve with speed-controlled flow in dependence of the runner revolution. It is technical innovation and new renewable source of energy, which can be in future used in rehabilitation or projecting of pumped-storage power plants. It also increases the power of the power plant.

  7. Respiratory System Function in Patients After Minimally Invasive Aortic Valve Replacement Surgery: A Case Control Study.

    PubMed

    Stoliński, Jarosław; Musiał, Robert; Plicner, Dariusz; Andres, Janusz

    The aim of the study was to comparatively analyze respiratory system function after minimally invasive, through right minithoracotomy aortic valve replacement (RT-AVR) to conventional AVR. Analysis of 201 patients scheduled for RT-AVR and 316 for AVR between January 2010 and November 2013. Complications of the respiratory system and pulmonary functional status are presented. Complications of the respiratory system occurred in 16.8% of AVR and 11.0% of RT-AVR patients (P = 0.067). The rate of pleural effusions, thoracenteses, pneumonias, or phrenic nerve dysfunctions was not significantly different between groups. Perioperative mortality was 1.9% in AVR and 1.0% in RT-AVR (P = 0.417). Mechanical ventilation time after surgery was 9.7 ± 5.9 hours for AVR and 7.2 ± 3.2 hours for RT-AVR patients (P < 0.001). Stroke (odds ratio [OR] = 13.4, P = 0.008), increased postoperative blood loss (OR = 9.6, P < 0.001), and chronic obstructive pulmonary disease (OR = 7.7, P < 0.001) were risk factors of prolonged mechanical lung ventilation. A week after surgery, the results of most pulmonary function tests were lower in the AVR than in the RT-AVR group (P < 0.001 was seen for forced expiratory volume in the first second, vital capacity, total lung capacity, maximum inspiratory pressure and maximum expiratory pressure, P = 0.377 was seen for residual volume). Right anterior aortic valve replacement minithoracotomy surgery with single-lung ventilation did not result in increased rate of respiratory system complications. Spirometry examinations revealed that pulmonary functional status was more impaired after AVR in comparison with RT-AVR surgery.

  8. Closed bore XMR (CBXMR) systems for aortic valve replacement: active magnetic shielding of x-ray tubes.

    PubMed

    Bracken, John A; DeCrescenzo, Giovanni; Komljenovic, Philip; Lillaney, Prasheel V; Fahrig, Rebecca; Rowlands, J A

    2009-05-01

    Hybrid closed bore x-ray/MRI systems are being developed to improve the safety and efficacy of percutaneous aortic valve replacement procedures by harnessing the complementary strengths of the x-ray and MRI modalities in a single interventional suite without requiring patient transfer between two rooms. These systems are composed of an x-ray C-arm in close proximity (approximately 1 m) to an MRI scanner. The MRI magnetic fringe field can cause the electron beam in the x-ray tube to deflect. The deflection causes the x-ray field of view to shift position on the detector receptacle. This could result in unnecessary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. Therefore, the electron beam deflection must be corrected. The authors developed an active magnetic shielding system that can correct for electron beam deflection to within an accuracy of 5% without truncating the field of view or increasing exposure to the patient. This system was able to automatically adjust to different field strengths as the external magnetic field acting on the x-ray tube was changed. Although a small torque was observed on the shielding coils of the active shielding system when they were placed in a magnetic field, this torque will not impact their performance if they are securely mounted on the x-ray tube and the C-arm. The heating of the coils of the shielding system for use in the clinic caused by electric current was found to be slow enough not to require a dedicated cooling system for one percutaneous aortic valve replacement procedure. However, a cooling system will be required if multiple procedures are performed in one session.

  9. Validity of standard gamble utilities in patients referred for aortic valve replacement.

    PubMed

    Hussain, Amjad I; Garratt, Andrew M; Beitnes, Jan Otto; Gullestad, Lars; Pettersen, Kjell I

    2016-07-01

    Standard gamble (SG) is the preferred method of assessing preferences in situations with uncertainty and risk, which makes it relevant to patients considered for aortic valve replacement (AVR). The present study assesses SG preferences in patients with severe aortic stenosis (AS). All patients >18 years old with severe AS referred for AVR to our institution were invited to enroll in the study. The SG was administered by a clinical research nurse. The SF-36, EQ-5D 3L, Hospital Anxiety and Depression Scale (HADS), and AS symptoms were administered by self-completed questionnaire. We hypothesized that SG utilities would have low-to-moderate correlations with physical and mental aspects of health based on our pathophysiological understanding of severe AS. No correlations were expected with echocardiographic measures of the aortic valve. The response rate for SG was 98 %. SG moderately correlated with physical aspects of SF-36 (PCS, role-physical, vitality), health transition, AS symptoms, and EQ-VAS (ρ S = 0.31-0.39, p < 0.001) and had low correlation with mental aspects of SF-36 and EQ-5D (ρ S = 0.17-0.28, p < 0.001). No correlation was found between SG and HADS, echocardiographic measures, age, gender, or education level (ρ S = 0.01-0.06). SG is an acceptable and feasible method of assessing preferences in patients with severe AS that has evidence for validity. The inclusion of uncertainty lends the SG face validity in this population as a direct approach to assessing preferences and basis for QALY calculations.

  10. Performance of stented biological valves for right ventricular outflow tract reconstruction.

    PubMed

    Buchholz, Christian; Mayr, Andreas; Purbojo, Ariawan; Glöckler, Martin; Toka, Okan; Cesnjevar, Robert A; Rüffer, André

    2016-12-01

    This retrospective single-centre review presents mid- and long-term results of stented biological valves (SBVs) in the pulmonary position. Fifty-two SBVs (17 Carpentier-Edwards Supraannular; 13 Carpentier-Edwards Perimount; 12 St. Jude Medical Trifecta; 4 Sorin Mitroflow; 4 Sorin Soprano; 2 Sorin More) were implanted between 2000 and 2015. The median valve size, patient age and weight were 23 mm (range 19-27), 22.8 years (range 5-77) and 62.0 kg (range 14-110), respectively. The main cardiac diagnosis was tetralogy of Fallot in 26 patients (50%). Forty-four patients (85%) had previous cardiac surgery; 12 patients (23%) had previous conduit or biological valve replacement. Valve degeneration was defined as a valvular peak pressure gradient >50 mmHg or pulmonary valve regurgitation more than moderate. The mean follow-up was 7.9 ± 5.5 years. Two patients died after 5.8 and 6.1 years of causes not related to SBVs. Eleven SBVs (21%) had to be replaced surgically (n = 6) or interventionally (n = 5) after 9.0 ± 4.1 years due to valve degeneration (n = 8), endocarditis (n = 2) or right ventricular dysfunction (n = 1). The rates of freedom from valve replacement were 100%, 92% [95% confidence interval (CI) 79-97], 81% (CI 64-91) and 60% (CI 40-78) after 1, 5, 10 and 15 years, respectively. Successful interventional valve-in-valve implantation resulted in 100% freedom from surgical valve replacement in all patients older than 19.1 years. Multivariate analysis identified patient age <19.1 years (P = 0.007) as a risk factor for earlier valve degeneration. SBVs in the pulmonary position showed encouraging long-term results in mature patients. The design of SBVs enables interventional valve implantation, postponing the need for reoperation. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI.

    PubMed

    Auffret, Vincent; Lefevre, Thierry; Van Belle, Eric; Eltchaninoff, Hélène; Iung, Bernard; Koning, René; Motreff, Pascal; Leprince, Pascal; Verhoye, Jean Philippe; Manigold, Thibaut; Souteyrand, Geraud; Boulmier, Dominique; Joly, Patrick; Pinaud, Frédéric; Himbert, Dominique; Collet, Jean Philippe; Rioufol, Gilles; Ghostine, Said; Bar, Olivier; Dibie, Alain; Champagnac, Didier; Leroux, Lionel; Collet, Frédéric; Teiger, Emmanuel; Darremont, Olivier; Folliguet, Thierry; Leclercq, Florence; Lhermusier, Thibault; Olhmann, Patrick; Huret, Bruno; Lorgis, Luc; Drogoul, Laurent; Bertrand, Bernard; Spaulding, Christian; Quilliet, Laurent; Cuisset, Thomas; Delomez, Maxence; Beygui, Farzin; Claudel, Jean-Philippe; Hepp, Alain; Jegou, Arnaud; Gommeaux, Antoine; Mirode, Anfani; Christiaens, Luc; Christophe, Charles; Cassat, Claude; Metz, Damien; Mangin, Lionel; Isaaz, Karl; Jacquemin, Laurent; Guyon, Philippe; Pouillot, Christophe; Makowski, Serge; Bataille, Vincent; Rodés-Cabau, Josep; Gilard, Martine; Le Breton, Hervé

    2017-07-04

    Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry, which captured all TAVRs performed from January 2010 to January 2012 across 34 centers. A total of 12,804 patients from FRANCE TAVI and 4,165 patients from FRANCE 2 were included in this analysis. The median age of patients was 84.6 years, and 49.7% were men. FRANCE TAVI participants were older but at lower surgical risk (median logistic European System for Cardiac Operative Risk Evaluation [EuroSCORE]: 15.0% vs. 18.4%; p < 0.001). More than 80% of patients in FRANCE TAVI underwent transfemoral TAVR. Transesophageal echocardiography guidance decreased from 60.7% to 32.3% of cases, whereas more recent procedures were increasingly performed in hybrid operating rooms (15.8% vs. 35.7%). Rates of Valve Academic Research Consortium-defined device success increased from 95.3% in FRANCE 2 to 96.8% in FRANCE TAVI (p < 0.001). In-hospital and 30-day mortality rates were 4.4% and 5.4%, respectively, in FRANCE TAVI compared with 8.2% and 10.1%, respectively, in FRANCE 2 (p < 0.001 for both). Stroke and potentially life-threatening complications, such as annulus rupture or aortic dissection, remained stable over time, whereas rates of cardiac tamponade and pacemaker implantation significantly increased. The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all

  12. Cardiovascular Collapse During Transcatheter Aortic Valve Replacement: Diagnosis and Treatment of the “Perilous Pentad”

    PubMed Central

    El-Gamel, Adam

    2013-01-01

    Transcatheter aortic valve replacement (TAVR) has, without a doubt, brought an unprecedented excitement to the field of interventional cardiology. The avoidance of a sternotomy by transfemoral or transapical aortic-valve implantation appears to come at the price of some serious complications, including an increased risk of embolic stroke and paravalvular leakage. The technical challenges of the procedure and the complex nature of the high-risk patient cohort make the learning curve for this procedure a steep one, with the potential for unexpected complications always looming. Although most commonly relating to vascular access, these complications can also result from prosthesis-related trauma or malposition, or from unanticipated trauma from the pacing wire or the super stiff wire. Sudden and unexplained hypotension is often the earliest indicator of major complication and must prompt an immediate and detailed exclusion of five major pathologies: retroperitoneal bleeding from access site rupture, aortic dissection or rupture, pericardial tamponade, coronary ostial obstruction, or acute severe aortic regurgitation. In most cases, these can be dealt with quickly, and by percutaneous means, although open surgery may occasionally be necessary. Increased operator and team experience should make prevention and recognition of these catastrophic complications more complete. For this reason, the importance of specific training, such as that provided by the valve manufacturers through workshops and proctorship, cannot be overemphasized. It is essential that all operators, and indeed all members of the implant team, exert extreme vigilance to the development of intraprocedural complications, which could have rapid and potentially lethal consequences. Greater experience with an improved understanding of these risks, along with the development of better devices, deliverable through smaller and less traumatic sheath technology, will undoubtedly improve the safety and

  13. SLM Produced Hermetically Sealed Isolation Valve

    NASA Technical Reports Server (NTRS)

    Richard, James

    2014-01-01

    Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic-driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic-based valve.

  14. SLM Produced Hermetically Sealed Isolation Valve

    NASA Technical Reports Server (NTRS)

    Richard, James A.

    2014-01-01

    Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic based valve.

  15. Hybrid textile heart valve prosthesis: preliminary in vitro evaluation.

    PubMed

    Vaesken, Antoine; Pidancier, Christian; Chakfe, Nabil; Heim, Frederic

    2016-09-22

    Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.

  16. Life-threatening subdural hematoma after aortic valve replacement in a patient with Heyde syndrome: a case report.

    PubMed

    Uchida, Tetsuro; Hamasaki, Azumi; Ohba, Eiichi; Yamashita, Atsushi; Hayashi, Jun; Sadahiro, Mitsuaki

    2017-08-08

    Heyde syndrome is known as a triad of calcific aortic stenosis, anemia due to gastrointestinal bleeding from angiodysplasia, and acquired type 2A von Willebrand disease. This acquired hemorrhagic disorder is characterized by the loss of the large von Willebrand factor multimers due to the shear stress across the diseased aortic valve. The most frequently observed type of bleeding in these patients is mucosal or skin bleeding, such as epistaxis, followed by gastrointestinal bleeding. On the other hand, intracranial hemorrhage complicating Heyde syndrome is extremely rare. A 77-year-old woman presented to our hospital with severe aortic stenosis and severe anemia due to gastrointestinal bleeding and was diagnosed with Heyde syndrome. Although aortic valve replacement was performed without recurrent gastrointestinal bleeding, postoperative life-threatening acute subdural hematoma occurred with a marked midline shift. Despite prompt surgical evacuation of the hematoma, she did not recover consciousness and she died 1 month after the operation. Postoperative subdural hematoma is rare, but it should be kept in mind as a devastating hemorrhagic complication, especially in patients with Heyde syndrome.

  17. Comparative outcomes of transcatheter aortic valve replacement in African American and Caucasian patients with severe aortic stenosis.

    PubMed

    Alqahtani, Fahad; Aljohani, Sami; Almustafa, Ahmad; Alhijji, Mohammed; Ali, Oluseun; Holmes, David R; Alkhouli, Mohamad

    2018-04-01

    Racial disparities in cardiovascular care have been extensively investigated. The introduction of transcatheter aortic valve replacement (TAVR) revolutionized the treatment of aortic stenosis (AS) in the last decade. Whether a racial disparity in the utilization and outcome of TAVR exists is unknown. We utilized the nationwide inpatient sample (NIS) to compare utilization rates, and in-hospital outcomes of Caucasians and African American (AA) patients who underwent TAVR between August 2011 and December 2014. A total of 7,176 patients (6870 Caucasians, 95.7%) and (306 AAs, 4.3%) were included in this analysis. Among patients who underwent aortic valve replacement between 2011 and 2014, the rates of TAVR utilization increased from 0.32% to 7.6% in AAs and from 0.4% to 8.8% in Caucasians. In propensity-matched cohorts of patients (n = 300 Caucasians and n = 300 AAs), in-hospital mortality was similar (3.7% and 3.3%, respectively, P = 0.99). Also, rates of key complications including stroke, permanent pacemaker implantation (PPMI), vascular complications, acute kidney injury, new dialysis, blood transfusion, and tamponade were similar in both races. There was also no significant difference between Caucasians and AAs with regards to length of stay, cost of hospitalization, and intermediate care facility utilization. There was no significant difference in the utilization rates, in-hospital outcomes, and cost of TAVR between Caucasians and AA patients in contemporary US practice. Further comparative studies of surgical and TAVR in AAs and other racial minorities are warranted. © 2017 Wiley Periodicals, Inc.

  18. Patients' self-reported function, symptoms and health-related quality of life before and 6 months after transcatheter aortic valve implantation and surgical aortic valve replacement.

    PubMed

    Olsson, Karin; Nilsson, Johan; Hörnsten, Åsa; Näslund, Ulf

    2017-03-01

    Aortic stenosis is the most common valve disease in western countries and has poor prognosis without treatment. Surgical aortic valve replacement (SAVR) is the gold standard, and transcatheter aortic valve implantation (TAVI) is a new method that is used in high-risk patients who are denied surgery. The purpose of treatment is not only to save life, but also to reduce symptoms and increase health-related quality of life (HRQoL). The aim of this study was to describe patients' self-reported outcomes in terms of physical function, symptoms, dependence, HRQoL, and cognitive function after TAVI and SAVR. All patients treated with TAVI during 1 year ( n = 24) and age-matched patients treated with SAVR ( n = 24) were included. Data were collected on the day before and at 6 months after treatment using structural questionnaires. Self-rated function was low before treatment and increased at follow-up. A quarter of all patients reported syncope at baseline, and none reported this at follow-up. Breathlessness was reported by all patients to be the most limiting cardiac symptom, but the TAVI patients reported more severe symptoms. At 6 months' follow-up, symptoms were reduced, but breathlessness and fatigue were still common, especially in the TAVI group. HRQoL, which was very low in the TAVI group at baseline, increased in all dimensions except social function. We found no change in cognitive function or dependence at follow-up. There was no difference in the size of improvement between groups. The results could be helpful when informing future patients in order to give them realistic expectations.

  19. Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk

    PubMed Central

    Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E.

    2015-01-01

    Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient. PMID:26346128

  20. Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk.

    PubMed

    Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E

    2015-01-01

    Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient.

  1. Using Time-Driven Activity-Based Costing as a Key Component of the Value Platform: A Pilot Analysis of Colonoscopy, Aortic Valve Replacement and Carpal Tunnel Release Procedures

    PubMed Central

    Martin, Jacob A.; Mayhew, Christopher R.; Morris, Amanda J.; Bader, Angela M.; Tsai, Mitchell H.; Urman, Richard D.

    2018-01-01

    Background Time-driven activity-based costing (TDABC) is a methodology that calculates the costs of healthcare resources consumed as a patient moves along a care process. Limited data exist on the application of TDABC from the perspective of an anesthesia provider. We describe the use of TDABC, a bottom-up costing strategy and financial outcomes for three different medical-surgical procedures. Methods In each case, a multi-disciplinary team created process maps describing the care delivery cycle for a patient encounter using the TDABC methodology. Each step in a process map delineated an activity required for delivery of patient care. The resources (personnel, equipment and supplies) associated with each step were identified. A per minute cost for each resource expended was generated, known as the capacity cost rate, and multiplied by its time requirement. The total cost for an episode of care was obtained by adding the cost of each individual resource consumed as the patient moved along a clinical pathway. Results We built process maps for colonoscopy in the gastroenterology suite, calculated costs of an aortic valve replacement by comparing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR) techniques, and determined the cost of carpal tunnel release in an operating room versus an ambulatory procedure room. Conclusions TDABC is central to the value-based healthcare platform. Application of TDABC provides a framework to identify process improvements for health care delivery. The first case demonstrates cost-savings and improved wait times by shifting some of the colonoscopies scheduled with an anesthesiologist from the main hospital to the ambulatory facility. In the second case, we show that the deployment of an aortic valve via the transcatheter route front loads the costs compared to traditional, surgical replacement. The last case demonstrates significant cost savings to the healthcare system associated with re

  2. Replacement of the aortic root with a composite valve-graft conduit: risk factor analysis in 246 consecutive patients.

    PubMed

    Woldendorp, Kei; Starra, Eric; Seco, Michael; Hendel, P Nicholas; Jeremy, Richmond W; Wilson, Michael K; Vallely, Michael P; Bannon, Paul G

    2014-12-01

    Composite valve-graft (CVG) replacement of the aortic root is a well-studied and recognised treatment for various aortic root conditions, including valvular disease with associated aortopathy. There have been few previous studies of the procedure in large numbers in an Australian setting. From January 2006 to June 2013, 246 successive patients underwent CVG root replacements at our institution. Mean age was 56.8 years, 85.4% were male, and 87 had evidence of bicuspid aortic valve. Indications for operation included ascending aortic aneurysm in 222 patients, annuloaortic ectasia in 67 patients, and aortic dissection in 38 patients. The overall unit 30-day mortality was 5.7%, including: elective 30-day mortality of 2.2%, and emergent 30-day mortality of 17.2%. Statistically significant multivariate predictors of 30-day mortality were: acute aortic dissection (OR=20.07), peripheral vascular disease (OR=11.17), new ventricular tachycardia (OR=30.17), re-operation for bleeding (OR=14.42), concomitant mitral stenosis (OR=68.30), and cerebrovascular accident (OR=144.85). Low postoperative mortality in our series matches closely with results from similar sized international studies, demonstrating that this procedure can be performed with low risk in centres with sufficient experience in the operative procedure. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  3. Quality and Safety in Health Care, Part XXX: Transcatheter Aortic Valve Therapy.

    PubMed

    Harolds, Jay A

    2017-12-01

    Initially, the transcatheter aortic valve replacement procedure was approved only for patients with aortic stenosis that was both severe and symptomatic who either also had too high a risk of aortic valve replacement surgery to have the surgery or who had a high risk for the surgery. Between the years 2012 and 2015, the death rate at 30 days declined from an initial rate of 7.5% to 4.6%. There has also been more use of the transfemoral approach over the years. In 2016, the transcatheter aortic valve replacement was approved for patients with aortic stenosis at intermediate risk of surgery.

  4. Postoperative Reverse Remodeling and Symptomatic Improvement in Normal-Flow Low-Gradient Aortic Stenosis After Aortic Valve Replacement.

    PubMed

    Carter-Storch, Rasmus; Møller, Jacob E; Christensen, Nicolaj L; Irmukhadenov, Akhmadjon; Rasmussen, Lars M; Pecini, Redi; Øvrehus, Kristian A; Søndergård, Eva V; Marcussen, Niels; Dahl, Jordi S

    2017-12-01

    Severe aortic stenosis (AS) most often presents with reduced aortic valve area (<1 cm 2 ), normal stroke volume index (≥35 mL/m 2 ), and either high mean gradient (≥40 mm Hg; normal-flow high-gradient AS) or low mean gradient (normal-flow low-gradient [NFLG] AS). The benefit of aortic valve replacement (AVR) among NFLG patients is controversial. We compared the impact of NFLG condition on preoperative left ventricular (LV) remodeling and myocardial fibrosis and postoperative remodeling and symptomatic benefit. Eighty-seven consecutive patients with reduced aortic valve area and normal stroke volume index undergoing AVR underwent echocardiography, magnetic resonance imaging, a 6-minute walk test, and measurement of natriuretic peptides before and 1 year after AVR. Myocardial fibrosis was assessed from magnetic resonance imaging. Patients were stratified as NFLG or normal-flow high-gradient. In total, 33 patients (38%) had NFLG. Before AVR, they were characterized by similar symptom burden but less severe AS measured by aortic valve area index (0.50±0.09 versus 0.40±0.08 cm 2 /m 2 ; P <0.0001), lower LV mass index (74±18 versus 90±26 g/m 2 ; P =0.01), but the same degree of myocardial fibrosis. After AVR, NFLG had a smaller reduction in LV mass index (-3±10 versus -±18 g/m 2 ; P <0.0001) and a smaller reduction in natriuretic peptides. Both groups experienced similar symptomatic improvement. Normal-flow high-gradient condition independently predicted change in LV mass index. Patients with NFLG had less severe AS and LV remodeling than patients with normal-flow high-gradient. Furthermore, NFLG patients experienced less reverse remodeling but the same symptomatic benefit. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02316587. © 2017 American Heart Association, Inc.

  5. Perioperative Results and Complications in 15,964 Transcatheter Aortic Valve Replacements: Prospective Data From the GARY Registry.

    PubMed

    Walther, Thomas; Hamm, Christian W; Schuler, Gerhard; Berkowitsch, Alexander; Kötting, Joachim; Mangner, Norman; Mudra, Harald; Beckmann, Andreas; Cremer, Jochen; Welz, Armin; Lange, Rüdiger; Kuck, Karl-Heinz; Mohr, Friedrich W; Möllmann, Helge

    2015-05-26

    Transcatheter aortic valve replacement (TAVR) has evolved into a routine procedure with good outcomes in high-risk patients. TAVR complication rates were evaluated based on prospective data from the German Aortic Valve Registry (GARY). From 2011 to 2013, a total of 15,964 TAVR procedures were registered. We evaluated the total cohort for severe vital complications (SVCs), including the following: death on the day of intervention, conversion to sternotomy, low cardiac output that required mechanical support, aortic dissection, and annular rupture; technical complications of the procedures (TCOs), such as repositioning or retrieval of the valve prosthesis and embolization of the prosthesis; and other complications. Mean patient age was 81 ± 6 years, 54% of the patients were women, the median logistic Euroscore I was 18.3, the German aortic valve score was 5.6, and the Society of Thoracic Surgeons score was 5.0. Overall in-hospital mortality was 5.2%, whereas SVCs occurred in 5.0% of the population. Independent predictors for SVCs were female sex, pre-operative New York Heart Association functional class IV, ejection fraction <30%, pre-operative intravenous inotropes, arterial vascular disease, and higher degree of calcifications. TCOs occurred in 4.7% of patients and decreased significantly from 2011 to 2013. An emergency sternotomy was performed in 1.3% of the patients; however, multivariate analysis did not identify any predictors for conversion to sternotomy. The all-comers GARY registry revealed good outcomes after TAVR and a regression in complications. Survival of approximately 60% of patients who experienced SVCs or who required sternotomy underlines the need for heart team-led indication, intervention, and follow-up care of TAVR patients. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Vortex dynamics in Patient-Specific Stenotic Tricuspid and Bicuspid Aortic Valves pre- and post- Trans-catheter Aortic Valve Replacement

    NASA Astrophysics Data System (ADS)

    Hatoum, Hoda; Dasi, Lakshmi Prasad

    2017-11-01

    Understanding blood flow related adverse complications such as leaflet thrombosis post-transcatheter aortic valve implantation (TAVI) requires a deeper understanding of how patient-specific anatomic and hemodynamic factors, and relative valve positioning dictate sinus vortex flow and stasis regions. High resolution time-resolved particle image velocimetry measurements were conducted in compliant and transparent 3D printed patient-specific models of stenotic bicuspid and tricuspid aortic valve roots from patients who underwent TAVI. Using Lagrangian particle tracking analysis of sinus vortex flows and probability distributions of residence time and blood damage indices we show that (a) patient specific modeling provides a more realistic assessment of TAVI flows, (b) TAVI deployment alters sinus flow patterns by significantly decreasing sinus velocity and vorticity, and (c) relative valve positioning can control critical vortex structures that may explain preferential leaflet thrombosis corresponding to separated flow recirculation, secondary to valve jet vectoring relative to the aorta axis. This work provides new methods and understanding of the spatio-temporal aortic sinus vortex dynamics in post TAVI pathology. This study was supported by the Ohio State University DHLRI Trifit Challenge award.

  7. Surgical outcomes in native valve infectious endocarditis: the experience of the Cardiovascular Surgery Department - Cluj-Napoca Heart Institute.

    PubMed

    Molnar, Adrian; Muresan, Ioan; Trifan, Catalin; Pop, Dana; Sacui, Diana

    2015-01-01

    The introduction of Duke's criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. The patients' age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases - 21%), Staphylococcus Spp. (15 cases - 15%), and Enterococcus Spp. (9 cases - 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases - 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases - 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases - 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve - mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was

  8. Heart valve surgery - discharge

    MedlinePlus

    ... weeks, or when you can easily climb 2 flights of stairs or walk a half-mile (800 ... vomiting or diarrhea You become pregnant or are planning to become pregnant Alternative Names Aortic valve replacement - ...

  9. Efficacy of the Stonehenge Technique for Minimally Invasive Aortic Valve Replacement via Right Infraaxillary Thoracotomy.

    PubMed

    Yamazaki, Masataka; Kin, Hajime; Kitamoto, Shohei; Yamanaka, Shota; Nishida, Hidefumi; Nishigawa, Kosaku; Takanashi, Shuichiro

    2017-02-20

    Minimally invasive cardiac surgeries for aortic valve replacement (AVR) are still a technical challenge for surgeons because these procedures are undertaken through small incisions and deep surgical fields. Although AVR via vertical infraaxillary thoracotomy can be a cosmetically superior option, a disadvantage of this approach is the distance between the thoracotomy incision and the ascending aorta. Therefore, we devised a technique to perform all manipulations using the fingertips without the aid of a knot pusher or long-shafted surgical instruments. This was achieved by particular placement of several retracted sutures to the right chest wall. We named placement of these sutures the "Stonehenge technique." In conclusion, AVR via vertical infraaxillary thoracotomy with our Stonehenge technique can be safely and simply performed with superior cosmetic advantages.

  10. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.

    PubMed

    Rampat, Rajiv; Khawaja, M Zeeshan; Hilling-Smith, Roland; Byrne, Jonathan; MacCarthy, Philip; Blackman, Daniel J; Krishnamurthy, Arvindra; Gunarathne, Ashan; Kovac, Jan; Banning, Adrian; Kharbanda, Raj; Firoozi, Sami; Brecker, Stephen; Redwood, Simon; Bapat, Vinayak; Mullen, Michael; Aggarwal, Suneil; Manoharan, Ganesh; Spence, Mark S; Khogali, Saib; Dooley, Maureen; Cockburn, James; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-06-26

    The authors report the incidence of pacemaker implantation up to hospital discharge and the factors influencing pacing rate following implantation of the LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts) in the United Kingdom. Transcatheter aortic valve replacement (TAVR) is associated with a significant need for permanent pacemaker implantation. Pacing rates vary according to the device used. The REPRISE II (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System) trial reported a pacing rate of 29% at 30 days after implantation of the LOTUS device. Data were collected retrospectively on 228 patients who had the LOTUS device implanted between March 2013 and February 2015 across 10 centers in the United Kingdom. Twenty-seven patients (12%) had pacemakers implanted pre-procedure and were excluded from the analysis. Patients were aged 81.2 ± 7.7 years; 50.7% were male. The mean pre-procedural QRS duration was 101.7 ± 20.4 ms. More than one-half of the cohort (n = 111, 55%) developed new left bundle branch block (LBBB) following the procedure. Permanent pacemakers were implanted in 64 patients (32%) with a median time to insertion of 3.0 ± 3.4 days. Chief indications for pacing were atrioventricular (AV) block (n = 46, 72%), or LBBB with 1st degree AV block (n = 11, 17%). Amongst those who received a pacemaker following TAVR the pre-procedural electrocardiogram findings included: No conduction disturbance (n = 41, 64%); 1st degree AV block (n = 10, 16%); right bundle branch block (n = 6, 9%) and LBBB (n = 5, 8%). LBBB (but not permanent pacemaker) occurred more frequently in patients who had balloon aortic valvuloplasty before TAVR (odds ratio [OR]: 1.25; p = 0.03). Pre-procedural conduction abnormality (composite of 1st degree AV block, hemiblock, right bundle branch block, LBBB) was independently associated with the need for permanent pacemaker (OR: 2.54; p = 0.048). The absence of

  11. Society of Thoracic Surgeons Risk Score Predicts Hospital Charges and Resource Utilization After Aortic Valve Replacement

    PubMed Central

    Arnaoutakis, George J.; George, Timothy J.; Alejo, Diane E.; Merlo, Christian A.; Baumgartner, William A.; Cameron, Duke E.; Shah, Ashish S.

    2011-01-01

    Context The impact of Society of Thoracic Surgeons (STS) predicted mortality risk score on resource utilization after aortic valve replacement (AVR) has not been previously studied. Objective We hypothesize that increasing STS risk scores in patients having AVR are associated with greater hospital charges. Design, Setting, and Patients Clinical and financial data for patients undergoing AVR at a tertiary care, university hospital over a ten-year period (1/2000–12/2009) were retrospectively reviewed. The current STS formula (v2.61) for in-hospital mortality was used for all patients. After stratification into risk quartiles (Q), index admission hospital charges were compared across risk strata with Rank-Sum tests. Linear regression and Spearman’s coefficient assessed correlation and goodness of fit. Multivariable analysis assessed relative contributions of individual variables on overall charges. Main Outcome Measures Inflation-adjusted index hospitalization total charges Results 553 patients had AVR during the study period. Average predicted mortality was 2.9% (±3.4) and actual mortality was 3.4% for AVR. Median charges were greater in the upper Q of AVR patients [Q1–3,$39,949 (IQR32,708–51,323) vs Q4,$62,301 (IQR45,952–97,103), p=<0.01]. On univariate linear regression, there was a positive correlation between STS risk score and log-transformed charges (coefficient: 0.06, 95%CI 0.05–0.07, p<0.01). Spearman’s correlation R-value was 0.51. This positive correlation persisted in risk-adjusted multivariable linear regression. Each 1% increase in STS risk score was associated with an added $3,000 in hospital charges. Conclusions This study showed increasing STS risk score predicts greater charges after AVR. As competing therapies such as percutaneous valve replacement emerge to treat high risk patients, these results serve as a benchmark to compare resource utilization. PMID:21497834

  12. Closed bore XMR (CBXMR) systems for aortic valve replacement: Active magnetic shielding of x-ray tubes

    PubMed Central

    Bracken, John A.; DeCrescenzo, Giovanni; Komljenovic, Philip; Lillaney, Prasheel V.; Fahrig, Rebecca; Rowlands, J. A.

    2009-01-01

    Hybrid closed bore x-ray∕MRI systems are being developed to improve the safety and efficacy of percutaneous aortic valve replacement procedures by harnessing the complementary strengths of the x-ray and MRI modalities in a single interventional suite without requiring patient transfer between two rooms. These systems are composed of an x-ray C-arm in close proximity (≈1 m) to an MRI scanner. The MRI magnetic fringe field can cause the electron beam in the x-ray tube to deflect. The deflection causes the x-ray field of view to shift position on the detector receptacle. This could result in unnecessary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. Therefore, the electron beam deflection must be corrected. The authors developed an active magnetic shielding system that can correct for electron beam deflection to within an accuracy of 5% without truncating the field of view or increasing exposure to the patient. This system was able to automatically adjust to different field strengths as the external magnetic field acting on the x-ray tube was changed. Although a small torque was observed on the shielding coils of the active shielding system when they were placed in a magnetic field, this torque will not impact their performance if they are securely mounted on the x-ray tube and the C-arm. The heating of the coils of the shielding system for use in the clinic caused by electric current was found to be slow enough not to require a dedicated cooling system for one percutaneous aortic valve replacement procedure. However, a cooling system will be required if multiple procedures are performed in one session. PMID:19544789

  13. Valve-Sparing Root Replacement Compared With Composite Valve Graft Procedures in Patients With Aortic Root Dilation.

    PubMed

    Ouzounian, Maral; Rao, Vivek; Manlhiot, Cedric; Abraham, Nachum; David, Carolyn; Feindel, Christopher M; David, Tirone E

    2016-10-25

    Although aortic valve-sparing (AVS) operations are established alternatives to composite valve graft (CVG) procedures for patients with aortic root aneurysms, comparative long-term outcomes are lacking. This study sought to compare the results of patients undergoing AVS procedures with those undergoing CVG operations. From 1990 to 2010, a total of 616 patients age <70 years and without aortic stenosis underwent elective aortic root surgery (AVS, n = 253; CVG with a bioprosthesis [bio-CVG], n = 180; CVG with a mechanical prosthesis [m-CVG], n = 183). A propensity score was used as a covariate to adjust for unbalanced variables in group comparisons. Mean age was 46 ± 14 years, 83.3% were male, and mean follow-up was 9.8 ± 5.3 years. Patients undergoing AVS had higher rates of Marfan syndrome and lower rates of bicuspid aortic valve than those undergoing bio-CVG or m-CVG procedures. In-hospital mortality (0.3%) and stroke rate (1.3%) were similar among groups. After adjusting for clinical covariates, both bio-CVG and m-CVG procedures were associated with increased long-term major adverse valve-related events compared with patients undergoing AVS (hazard ratio [HR]: 3.4, p = 0.005; and HR: 5.2, p < 0.001, respectively). They were also associated with increased cardiac mortality (HR: 7.0, p = 0.001; and HR: 6.4, p = 0.003). Furthermore, bio-CVG procedures were associated with increased risk of reoperations (HR: 6.9; p = 0.003), and m-CVG procedures were associated with increased risk of anticoagulant-related hemorrhage (HR: 5.6; p = 0.008) compared with AVS procedures. This comparative study showed that AVS procedures were associated with reduced cardiac mortality and valve-related complications when compared with bio-CVG and m-CVG. AVS is the treatment of choice for young patients with aortic root aneurysm and normal or near-normal aortic cusps. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    PubMed

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Over 20 years experience with aortic homograft in aortic valve replacement during acute infective endocarditis.

    PubMed

    Solari, Silvia; Mastrobuoni, Stefano; De Kerchove, Laurent; Navarra, Emiliano; Astarci, Parla; Noirhomme, Philippe; Poncelet, Alain; Jashari, Ramadan; Rubay, Jean; El Khoury, Gebrine

    2016-12-01

    Despite the controversy, the aortic homograft is supposedly the best option in acute infective endocarditis (AIE), due to its resistance to reinfection. However, the technical complexity and the risk of structural deterioration over time have limited its utilization. The aim of this study was to evaluate the long-term results of aortic homograft for the treatment of infective endocarditis in our institution with particular attention to predictors of survival and homograft reoperation. The cohort includes 112 patients who underwent aortic valve replacement with an aortic homograft for AIE between January 1990 and December 2014. Fifteen patients (13.4%) died during the first 30 days after the operation. Two patients were lost to follow-up after discharge from the hospital; therefore, 95 patients were available for long-term analysis. The median duration of follow-up was 7.8 years (IQR 4.7-17.6). Five patients (5.3%) suffered a recurrence of infective endocarditis (1 relapse and 4 new episodes). Sixteen patients (16.8%) were reoperated for structural valve degeneration (SVD; n = 14, 87.5%) or for infection recurrence (n = 2, 12.5%). Freedom from homograft reoperation for infective endocarditis or structural homograft degeneration at 10 and 15 years postoperatively was 86.3 ± 5.5 and 47.3 ± 11.0%, respectively. For patients requiring homograft reoperation, the median interval to reintervention was 11.6 years (IQR 8.3-14.5). Long-term survival was 63.6% (95% CI 52.4-72.8%) and 53.8% (95% CI 40.6-65.3%) at 10 and 15 years, respectively. The use of aortic homograft in acute aortic valve endocarditis is associated with a remarkably low risk of relapsing infection and very acceptable long-term survival. The risk of reoperation due to SVD is significant after one decade especially in young patients. The aortic homograft seems to be ideally suited for reconstruction of the aortic valve and cardiac structures damaged by the infective process especially in early surgery.

  16. The effects of a low international normalized ratio on thromboembolic and bleeding complications in patients with mechanical mitral valve replacement

    PubMed Central

    2014-01-01

    Background Mechanical heart valve replacement has an inherent risk of thromboembolic events (TEs). Current guidelines recommend an international normalized ratio (INR) of at least 2.5 after mechanical mitral valve replacement (MVR). This study aimed to evaluate the effects of a low INR (2.0–2.5) on thromboembolic and bleeding complications in patients with mechanical MVR on warfarin therapy. Methods One hundred and thirty-five patients who underwent mechanical MVR were enrolled in this study. The end points of this study were defined as TEs (valve thrombosis, transient ischemic attack, stroke) and bleeding (all minor and major bleeding) complications. Patients were followed up for a mean of 39.6 months and the mean INR of the patients was calculated. After data collection, patients were divided into 3 groups according to their mean INR, as follows: group 1 (n = 34), INR <2.0; group 2 (n = 49), INR 2.0–2.5; and group 3 (n = 52), INR >2.5. Results A total of 22 events (10 [7.4%] thromboembolic and 12 [8.8%] bleeding events) occurred in the follow-up period. The mean INR was an independent risk factor for the development of TEs. Mean INR and neurological dysfunction were independent risk factors for the development of bleeding events. A statistically significant positive correlation was found between the log mean INR and all bleeding events, and a negative correlation was found between the log mean INR and all TEs. The total number of events was significantly lower in group 2 than in groups 1 and 3 (P = 0.036). Conclusions This study showed that a target INRs of 2.0–2.5 are acceptable for preventing TEs and safe in terms of bleeding complications in patients with mechanical MVR. PMID:24885719

  17. Echocardiographic parameters predicting acute hemodynamically significant mitral regurgitation during transfemoral transcatheter aortic valve replacement.

    PubMed

    Ito, Asahiro; Iwata, Shinichi; Mizutani, Kazuki; Nonin, Shinichi; Nishimura, Shinsuke; Takahashi, Yosuke; Yamada, Tokuhiro; Murakami, Takashi; Shibata, Toshihiko; Yoshiyama, Minoru

    2018-03-01

    Alteration in mitral valve morphology resulting from retrograde stiff wire entanglement sometimes causes hemodynamically significant acute mitral regurgitation (MR) during transfemoral transcatheter aortic valve replacement (TAVR). Little is known about the echocardiographic parameters related to hemodynamically significant acute MR. This study population consisted of 64 consecutive patients who underwent transfemoral TAVR. We defined hemodynamically significant acute MR as changes in the severity of MR with persistent hypotension (systolic blood pressure < 80-90 mm Hg or mean arterial pressure 30 mm Hg lower than baseline). Hemodynamically significant acute MR occurred in 5 cases (7.8%). Smaller left ventricular end-systolic diameter (LVDs), larger ratios of the coiled section of stiff wire tip to LVDs (wire-width/LVDs), and higher Wilkins score were significantly associated with hemodynamically significant acute MR (P < .05), whereas the parameters of functional MR (annular area, anterior-posterior diameter, tenting area, and coaptation length) were not. Moreover, when patients were divided into 4 groups according to wire-width/LVDs and Wilkins score, the group with the larger wire-width/LVDs and higher Wilkins score improved prediction rates (P < .05). Small left ventricle or wire oversizing and calcific mitral apparatus were predictive of hemodynamically significant acute MR. These findings are important for risk stratification, and careful monitoring using intraoperative transesophageal echocardiography may improve the safety in this population. © 2017, Wiley Periodicals, Inc.

  18. Intraluminal valves: development, function and disease

    PubMed Central

    Geng, Xin; Cha, Boksik; Mahamud, Md. Riaj

    2017-01-01

    ABSTRACT The circulatory system consists of the heart, blood vessels and lymphatic vessels, which function in parallel to provide nutrients and remove waste from the body. Vascular function depends on valves, which regulate unidirectional fluid flow against gravitational and pressure gradients. Severe valve disorders can cause mortality and some are associated with severe morbidity. Although cardiac valve defects can be treated by valve replacement surgery, no treatment is currently available for valve disorders of the veins and lymphatics. Thus, a better understanding of valves, their development and the progression of valve disease is warranted. In the past decade, molecules that are important for vascular function in humans have been identified, with mouse studies also providing new insights into valve formation and function. Intriguing similarities have recently emerged between the different types of valves concerning their molecular identity, architecture and development. Shear stress generated by fluid flow has also been shown to regulate endothelial cell identity in valves. Here, we review our current understanding of valve development with an emphasis on its mechanobiology and significance to human health, and highlight unanswered questions and translational opportunities. PMID:29125824

  19. Management of significant left main coronary disease before and after trans-apical transcatheter aortic valve replacement in a patient with severe and complex arterial disease.

    PubMed

    Paradis, Jean-Michel; George, Isaac; Kodali, Susheel

    2013-09-01

    We report the case of an 81-year-old woman with symptomatic severe aortic stenosis, extremely significant peripheral arterial disease, and obstructive coronary artery disease who underwent percutaneous coronary intervention via a transaxillary conduit immediately before a trans-apical transcatheter aortic valve replacement performed with a transfemoral device. After deployment of the transcatheter heart valve, there was a left main coronary obstruction and the patient required an emergent PCI. This multifaceted case clearly underlines the importance of a well functioning heart team including the interventional cardiologist, the cardiovascular surgeon, and the echocardiographer. Copyright © 2013 Wiley Periodicals, Inc.

  20. TriGuard™ HDH embolic deflection device for cerebral protection during transcatheter aortic valve replacement.

    PubMed

    Samim, Mariam; van der Worp, Bart; Agostoni, Pierfrancesco; Hendrikse, Jeroen; Budde, Ricardo P J; Nijhoff, Freek; Ramjankhan, Faiz; Doevendans, Pieter A; Stella, Pieter R

    2017-02-15

    This study aims to evaluate the safety and performance of the new embolic deflection device TriGuard™HDH in patients undergoing TAVR. Transcatheter aortic valve replacement (TAVR) is associated with a high incidence of new cerebral ischemic lesions. The use of an embolic protection device may reduce the frequency of TAVR-related embolic events. This prospective, single arm feasibility pilot study included 14 patients with severe symptomatic aortic stenosis scheduled for TAVR. Cerebral diffusion weighted magnetic resonance imaging (DWI) was planned in all patients one day before and at day 4 (±2) after the procedure. Major adverse cerebral and cardiac events (MACCEs) were recorded for all patients. Primary endpoints of this study were I) device performance success defined as coverage of the aortic arch takeoffs throughout the entire TAVR procedure and II) MACCE occurrence. Secondary endpoints included the number and the volume of new cerebral ischemic lesions on DWI. Thirteen patients underwent transfemoral TAVR and one patient a transapical procedure. Edwards SAPIEN valve prosthesis was implanted in 8 (57%) patients and Medtronic CoreValve prosthesis in the remaining 6 (43%). Predefined performance success of the TriGuard™HDH device was achieved in 9 (64%) patients. The composite endpoint MACCE occurred in none of the patients. Post-procedural DWI was performed in 11 patients. Comparing the DWI of these patients to a historical control group showed no reduction in number [median 5.5 vs. 5.0, P = 0.857], however there was a significant reduction in mean lesion volume per patient [median 13.8 vs. 25.1, P = 0.049]. This study showed the feasibility and safety of using the TriGuard™HDH for cerebral protection during TAVR. This device did not decrease the number of post-procedural new cerebral DWI lesions, however its use showed decreased lesion volume as compared to unprotected TAVR. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. 1-Year Clinical Outcomes in Women After Transcatheter Aortic Valve Replacement: Results From the First WIN-TAVI Registry.

    PubMed

    Chieffo, Alaide; Petronio, Anna Sonia; Mehilli, Julinda; Chandrasekhar, Jaya; Sartori, Samantha; Lefèvre, Thierry; Presbitero, Patrizia; Capranzano, Piera; Tchetche, Didier; Iadanza, Alessandro; Sardella, Gennaro; Van Mieghem, Nicolas M; Meliga, Emanuele; Dumonteil, Nicholas; Fraccaro, Chiara; Trabattoni, Daniela; Mikhail, Ghada; Sharma, Samin; Ferrer, Maria Cruz; Naber, Christoph; Kievit, Peter; Baber, Usman; Snyder, Clayton; Sharma, Madhav; Morice, Marie Claude; Mehran, Roxana

    2018-01-08

    This study sought to examine the safety and performance of contemporary transcatheter aortic valve replacement (TAVR) in an exclusive all-women TAVR population, and to further investigate the potential impact of female sex-specific characteristics on composite 1-year clinical outcomes. Women comprise ≥50% patients undergoing TAVR. Several data have shown the noninferiority of TAVR compared with surgical aortic valve replacement for symptomatic significant aortic stenosis, but no study so far has been specifically powered to detect differences by sex. The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multinational, prospective, observational registry of women undergoing TAVR for significant aortic stenosis, across 18 sites in Europe and 1 site in the United States, between January 2013 and December 2015. The primary Valve Academic Research Consortium (VARC)-2 efficacy endpoint was a composite of mortality, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction beyond 30 days. Secondary endpoints included composite 1-year death or stroke. Predictors of 1-year outcomes were determined using Cox regression methods. A total of 1,019 intermediate to high-risk women, with mean age 82.5 ± 6.3 years, mean European System for Cardiac Operative Risk Evaluation (EuroSCORE) I 17.8 ± 11.7% and mean Society of Thoracic Surgeons score 8.3 ± 7.4% were enrolled. TAVR was performed via transfemoral access in 90.6% and new-generation devices were used in 42.1%. The primary VARC-2 efficacy composite endpoint occurred in 111 (10.9%) patients beyond 30 days and in 167 (16.5%) patients at 1 year. The incidence of 1-year death or stroke was 13.9% (n = 141). Death occurred in 127 (12.5%) patients and stroke in 22 (2.2%) patients. Prior coronary revascularization (hazard ratio [HR]: 1.72; 95% confidence interval [CI]: 1.17 to 2.52; p = 0.006) and EuroSCORE I (HR: 1.02; 95% CI

  2. Surgical outcomes in native valve infectious endocarditis: the experience of the Cardiovascular Surgery Department – Cluj-Napoca Heart Institute

    PubMed Central

    MOLNAR, ADRIAN; MURESAN, IOAN; TRIFAN, CATALIN; POP, DANA; SACUI, DIANA

    2015-01-01

    Background and aims The introduction of Duke’s criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. Methods We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. Results The patients’ age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases – 21%), Staphylococcus Spp. (15 cases – 15%), and Enterococcus Spp. (9 cases – 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases – 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases – 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases – 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve – mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological

  3. Hereditary spherocytosis and elliptocytosis associated with prosthetic heart valve replacement: rheological study of erythrocyte modifications.

    PubMed

    Caprari, Patrizia; Tarzia, Anna; Mojoli, Giorgio; Cianciulli, Paolo; Mannella, Emilio; Martorana, Maria Cristina

    2009-04-01

    The implantation of a prosthetic heart valve (HVP) in patients with hereditary spherocytosis (HS) and hereditary elliptocytosis (HE) is rare, and the changes in the structure and deformability of erythrocytes that follow implantation in these patients have been poorly described. In the present study, the erythrocytes in HS and HE patients with mechanical HVP were compared to the erythrocytes in patients with only congenital membrane defects, in terms of biochemical modifications and rheological behaviour. Integral and cytoskeletal erythrocyte membrane proteins were studied, and blood viscosity (shear rate/shear stress ratio), aggregation ratio [eta(1 s(-1))/eta(200 s(-1))], and red cell visco-elasticity were determined. Valve replacement with a mechanical prosthesis worsened anaemia and resulted in a change in haemolysis, from sub-clinical to evident. The rheological investigation of erythrocytes from HS patients confirmed the characteristic increased viscosity and aggregation ratio and the decreased deformability. The rheological behaviour of erythrocytes from patients with HVP showed a decrease in viscosity and an increase in elastic modulus. In these patients, the prosthesis seems to have induced traumatic damage to the erythrocyte membrane, leading to fragmentation and lysis, which in turn modified rheological parameters. The biochemical and rheological investigation allowed us to understand the clinical and haematological pictures of the patients and to describe the role played by different factors in haemolytic anaemia.

  4. Radiopaque Marker Addition During Aortic Root Replacement With the Use of a Freestyle Porcine Bioprosthesis.

    PubMed

    Crowley, Olivia M; Doty, John R

    2017-07-01

    Aortic root replacement is indicated for aortic root aneurysm, small aortic root, and most root abscesses. This report describes the placement of a radiopaque marker during aortic root replacement using a Freestyle porcine bioprosthesis. This marker is a useful landmark during fluoroscopy for transcatheter valve-in-valve aortic valve replacement in the event of bioprosthesis degeneration. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Pros and cons of transcatheter aortic valve implantation (TAVI).

    PubMed

    Terré, Juan A; George, Isaac; Smith, Craig R

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.

  6. Dilatation of the initially non-aneurysmal ascending aorta after replacement of a bicuspid versus tricuspid aortic valve.

    PubMed

    Zhang, Jing; Fan, Guangpu; Zhao, Hui; Wang, Xu; Wang, Zhiwei; Zhang, Peide; Wang, Wei

    2016-12-01

    Objective To compare the aortic diameter after isolated aortic valve replacement (AVR) in patients with a bicuspid (BAV) or tricuspid aortic valve (TAV) and an initially normal ascending aorta. Methods Patients with an ascending aortic diameter of < 45 mm who had undergone isolated AVR were studied. Ultrasonic cardiographic measurements of the ascending aortic diameter made pre- and postoperatively and follow-up data concerning adverse aortic events and death were analyzed. Results A total of 613 patients were included in this retrospective study; of these, 211 had a BAV and 402 had a TAV. In both groups, the ascending aorta significantly expanded but was non-aneurysmal during follow-up; however, the difference between the two groups was not significant. Cox regression analysis showed no significant effect associated with the presence of a BAV on adverse aortic events or death. Conclusion Dilatation of the ascending aorta was observed after AVR in both groups, but was not more pronounced in patients with a BAV. Long-term follow-up for ascending aortic aneurysm is necessary after AVR in both patients with a BAV and those with a TAV.

  7. Dilatation of the initially non-aneurysmal ascending aorta after replacement of a bicuspid versus tricuspid aortic valve

    PubMed Central

    Zhang, Jing; Fan, Guangpu; Zhao, Hui; Wang, Xu; Wang, Zhiwei; Zhang, Peide

    2016-01-01

    Objective To compare the aortic diameter after isolated aortic valve replacement (AVR) in patients with a bicuspid (BAV) or tricuspid aortic valve (TAV) and an initially normal ascending aorta. Methods Patients with an ascending aortic diameter of < 45 mm who had undergone isolated AVR were studied. Ultrasonic cardiographic measurements of the ascending aortic diameter made pre- and postoperatively and follow-up data concerning adverse aortic events and death were analyzed. Results A total of 613 patients were included in this retrospective study; of these, 211 had a BAV and 402 had a TAV. In both groups, the ascending aorta significantly expanded but was non-aneurysmal during follow-up; however, the difference between the two groups was not significant. Cox regression analysis showed no significant effect associated with the presence of a BAV on adverse aortic events or death. Conclusion Dilatation of the ascending aorta was observed after AVR in both groups, but was not more pronounced in patients with a BAV. Long-term follow-up for ascending aortic aneurysm is necessary after AVR in both patients with a BAV and those with a TAV. PMID:27484890

  8. Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

    PubMed Central

    Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin

    2015-01-01

    Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380

  9. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.

    PubMed

    Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  10. Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients

    PubMed Central

    Ma, Wei-Guo; Hou, Bin; Abdurusul, Adiljan; Gong, Ding-Xu; Tang, Yue; Chang, Qian; Xu, Jian-Ping

    2015-01-01

    Background Dysfunction of mechanical heart valve prostheses is an unusual but potentially lethal complication after mechanical prosthetic valve replacement. We seek to report our experience with mechanical valve dysfunction regarding etiology, surgical techniques and early outcomes. Methods Clinical data of 48 patients with mechanical valve dysfunction surgically treated between October 1996 and June 2011 were analyzed. Results Mean age was 43.7±10.9 years and 34 were female (70.8%). The median interval from primary valve implantation to dysfunction was 44.5 months (range, 1 hour to 20 years). There were 21 emergent and 27 elective reoperations. The etiology was thrombosis in 19 cases (39.6%), pannus in 12 (25%), thrombosis and pannus in 11 (22.9%), improper disc orientation in 2 (4.1%), missing leaflet in 1 (2.1%), excessively long knot end in 1 (2.1%), endogenous factor in 1 (2.1%) and unidentified in 1 (2.1%). Surgical procedure was mechanical valve replacement in 37 cases (77.1%), bioprosthetic valve replacement in 7 (14.9%), disc rotation in 2 (4.2%) and excision of excessive knot end in 1 (2.1%). Early deaths occurred in 7 patients (14.6%), due to low cardiac output in 3 (6.3%), multi-organ failure in 2 (4.2%) and refractory ventricular fibrillation in 2 (4.2%). Complications occurred in 10 patients (20.8%). Conclusions Surgical management of mechanical valve dysfunction is associated with significant mortality and morbidity. Earlier identification and prompt reoperation are vital to achieving better clinical outcomes. The high incidence of thrombosis in this series highlights the need for adequate anticoagulation and regular follow-up after mechanical valve replacement. PMID:26793354

  11. Intraoperative Assessment of Tricuspid Valve Function After Conservative Repair

    PubMed Central

    Revuelta, J.M.; Gomez-Duran, C.; Garcia-Rinaldi, R.; Gallagher, M.W.

    1982-01-01

    It is desirable to repair coexistent tricuspid valve pathology at the time of mitral valve corrections. Conservative tricuspid repair may consist of commissurotomy, annuloplasty, or both. It is important that the repair be appropriate or tricuspid valve replacement may be necessary. A simple reproducible method of intraoperative testing for tricuspid valve insufficiency has been developed and used in 25 patients. Fifteen patients have been recatheterized, and the correlation between the intraoperative and postoperative findings has been consistent. PMID:15226931

  12. Quantitative assessment of paravalvular leakage after transcatheter aortic valve replacement using a patient-specific pulsatile flow model.

    PubMed

    Tanaka, Yutaka; Saito, Shigeru; Sasuga, Saeko; Takahashi, Azuma; Aoyama, Yusuke; Obama, Kazuto; Umezu, Mitsuo; Iwasaki, Kiyotaka

    2018-05-01

    Quantitative assessment of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR) remains challenging. We developed patient-specific anatomical models with pulsatile flow circuit and investigated factors associated with AR after TAVR. Based on pre-procedural computed tomography (CT) data of the six patients who underwent transfemoral TAVR using a 23-mm SAPIEN XT, anatomically and mechanically equivalent aortic valve models were developed. Forward flow and heart rate of each patient in two days after TAVR were duplicated under mean aortic pressure of 80mmHg. Paravalvular leakage (PVL) volume in basal and additional conditions was measured for each model using an electromagnetic flow sensor. Incompletely apposed tract between the transcatheter and aortic valves was examined using a micro-CT. PVL volume in each patient-specific model was consistent with each patient's PVL grade, and was affected by hemodynamic conditions. PVL and total regurgitation volume increased with the mean aortic pressure, whereas closing volume did not change. In contrast, closing volume increased proportionately with heart rate, but PVL did not change. The minimal cross-sectional gap had a positive correlation with the PVL volumes (r=0.89, P=0.02). The gap areas typically occurred in the vicinity of the bulky calcified nodules under the native commissure. PVL volume, which could be affected by hemodynamic conditions, was significantly associated with the minimal cross-sectional gap area between the aortic annulus and the stent frame. These data may improve our understanding of the mechanism of the occurrence of post-TAVR PVL. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Efficacy of the Stonehenge Technique for Minimally Invasive Aortic Valve Replacement via Right Infraaxillary Thoracotomy

    PubMed Central

    Kin, Hajime; Kitamoto, Shohei; Yamanaka, Shota; Nishida, Hidefumi; Nishigawa, Kosaku; Takanashi, Shuichiro

    2017-01-01

    Minimally invasive cardiac surgeries for aortic valve replacement (AVR) are still a technical challenge for surgeons because these procedures are undertaken through small incisions and deep surgical fields. Although AVR via vertical infraaxillary thoracotomy can be a cosmetically superior option, a disadvantage of this approach is the distance between the thoracotomy incision and the ascending aorta. Therefore, we devised a technique to perform all manipulations using the fingertips without the aid of a knot pusher or long-shafted surgical instruments. This was achieved by particular placement of several retracted sutures to the right chest wall. We named placement of these sutures the “Stonehenge technique.” In conclusion, AVR via vertical infraaxillary thoracotomy with our Stonehenge technique can be safely and simply performed with superior cosmetic advantages. PMID:28123153

  14. Durability of hand-sewn valves in the right ventricular outlet.

    PubMed

    Nunn, Graham R; Bennetts, Jayme; Onikul, Ella

    2008-08-01

    The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained

  15. Concomitant tricuspid valve repair or replacement during left ventricular assist device implant demonstrates comparable outcomes in the long term.

    PubMed

    Deo, Salil V; Hasin, Tal; Altarabsheh, Salah E; McKellar, Stephen H; Shah, Ishan K; Durham, Lucian; Stulak, John M; Daly, Richard C; Park, Soon J; Joyce, Lyle D

    2012-11-01

    Severe tricuspid regurgitation (TR) is present in nearly half the patients undergoing implant of a left ventricular assist device (LVAD) and its correction confers better long-term outcome. To compare the early and late results of tricuspid valve repair (TVrpr) or replacement (TVR) with LVAD implant. Sixty-four from a cohort of 126 patients had a concomitant tricuspid valve procedure; 48 (75%) underwent a TVrpr whereas 16 (25%) had TVR. All preoperative hemodynamic parameters including the mean TR grade (TVrpr; 3.6 vs. TVR; 3.7) were comparable (p = 0.7). The mean TR grade was 1.6 ± 1.5 for the remaining 62 patients who did not have a concomitant tricuspid valve procedure, with 4/62 (6%) having severe TR (p < 0.0001). Cardiopulmonary bypass time was longer for patients undergoing TVR (p = 0.01). There was a significant reduction in right atrial pressure for the entire cohort (p < 0.01) and the postoperative right atrial pressure was not statistically different between TVrpr (13.6 ± 4.6) and TVR (11.6 ± 4.3; p = 0.6. Postoperative intensive care unit stay was comparable as was the duration of inotropic support (p = 0.5) or need for temporary right ventricular mechanical support. In-hospital mortality (12%) was not different between groups. The mean time for LVAD support was 12.3 ± 9.71 months and the last transthoracic echocardiographic examination was performed at mean intervals of 13.8 ± 10.8 months (TVrpr) and 11.8 ± 7.6 months (TVR; p = 0.47). Reduction in TR grade was similar between groups (p = 0.27). Late mortality (p = 1.00) was comparable in both groups. Using log-rank analysis, there was no significant difference in the estimated survival between TVrpr and TVR (p = 0.88). TVrpr repair at the time of LVAD implant is effective in correcting TR even at the end of one year of follow-up. The choice to repair or replace does not affect the clinical outcome. © 2012 Wiley Periodicals, Inc.

  16. Percutaneous re-revalvulation of the tricuspid valve.

    PubMed

    Gewillig, Marc; Dubois, Christophe

    2011-04-01

    We report a successful percutaneous revalvulation of a dysfunctional tricuspid bioprothesis in an 8-year-old child. Five years after implanting a 25-mm Carpentier-Edwards valve in the tricuspid position, the prosthesis showed significant dysfunction with clinical right heart failure. A 26-mm Edwards-Sapien XT inverted aortic valve was successfully implanted through a 19F sheath using a jugular approach. Such procedure can significantly postpone the need for surgical replacement of a biological valve. Copyright © 2011 Wiley-Liss, Inc.

  17. Society of Thoracic Surgeons 2008 cardiac risk models predict in-hospital mortality of heart valve surgery in a Chinese population: a multicenter study.

    PubMed

    Wang, Lv; Lu, Fang-Lin; Wang, Chong; Tan, Meng-Wei; Xu, Zhi-yun

    2014-12-01

    The Society of Thoracic Surgeons 2008 cardiac surgery risk models have been developed for heart valve surgery with and without coronary artery bypass grafting. The aim of our study was to evaluate the performance of Society of Thoracic Surgeons 2008 cardiac risk models in Chinese patients undergoing single valve surgery and the predicted mortality rates of those undergoing multiple valve surgery derived from the Society of Thoracic Surgeons 2008 risk models. A total of 12,170 patients underwent heart valve surgery from January 2008 to December 2011. Combined congenital heart surgery and aortal surgery cases were excluded. A relatively small number of valve surgery combinations were excluded. The final research population included the following isolated heart valve surgery types: aortic valve replacement, mitral valve replacement, and mitral valve repair. The following combined valve surgery types were included: mitral valve replacement plus tricuspid valve repair, mitral valve replacement plus aortic valve replacement, and mitral valve replacement plus aortic valve replacement and tricuspid valve repair. Evaluation was performed by using the Hosmer-Lemeshow test and C-statistics. Data from 9846 patients were analyzed. The Society of Thoracic Surgeons 2008 cardiac risk models showed reasonable discrimination and poor calibration (C-statistic, 0.712; P = .00006 in Hosmer-Lemeshow test). Society of Thoracic Surgeons 2008 models had better discrimination (C-statistic, 0.734) and calibration (P = .5805) in patients undergoing isolated valve surgery than in patients undergoing multiple valve surgery (C-statistic, 0.694; P = .00002 in Hosmer-Lemeshow test). Estimates derived from the Society of Thoracic Surgeons 2008 models exceeded the mortality rates of multiple valve surgery (observed/expected ratios of 1.44 for multiple valve surgery and 1.17 for single valve surgery). The Society of Thoracic Surgeons 2008 cardiac surgery risk models performed well when predicting the

  18. Comparison of 1-Year Outcome in Patients With Severe Aorta Stenosis Treated Conservatively or by Aortic Valve Replacement or by Percutaneous Transcatheter Aortic Valve Implantation (Data from a Multicenter Spanish Registry).

    PubMed

    González-Saldivar, Hugo; Rodriguez-Pascual, Carlos; de la Morena, Gonzalo; Fernández-Golfín, Covadonga; Amorós, Carmen; Alonso, Mario Baquero; Dolz, Luis Martínez; Solé, Albert Ariza; Guzmán-Martínez, Gabriela; Gómez-Doblas, Juan José; Jiménez, Antonio Arribas; Fuentes, María Eugenia; Gay, Laura Galian; Ortiz, Martin Ruiz; Avanzas, Pablo; Abu-Assi, Emad; Ripoll-Vera, Tomás; Díaz-Castro, Oscar; Osinalde, Eduardo P; Martínez-Sellés, Manuel

    2016-07-15

    The factors that influence decision making in severe aortic stenosis (AS) are unknown. Our aim was to assess, in patients with severe AS, the determinants of management and prognosis in a multicenter registry that enrolled all consecutive adults with severe AS during a 1-month period. One-year follow-up was obtained in all patients and included vital status and aortic valve intervention (aortic valve replacement [AVR] and transcatheter aortic valve implantation [TAVI]). A total of 726 patients were included, mean age was 77.3 ± 10.6 years, and 377 were women (51.8%). The most common management was conservative therapy in 468 (64.5%) followed by AVR in 199 (27.4%) and TAVI in 59 (8.1%). The strongest association with aortic valve intervention was patient management in a tertiary hospital with cardiac surgery (odds ratio 2.7, 95% confidence interval 1.8 to 4.1, p <0.001). The 2 main reasons to choose conservative management were the absence of significant symptoms (136% to 29.1%) and the presence of co-morbidity (128% to 27.4%). During 1-year follow-up, 132 patients died (18.2%). The main causes of death were heart failure (60% to 45.5%) and noncardiac diseases (46% to 34.9%). One-year survival for patients treated conservatively, with TAVI, and with AVR was 76.3%, 94.9%, and 92.5%, respectively, p <0.001. One-year survival of patients treated conservatively in the absence of significant symptoms was 97.1%. In conclusion, most patients with severe AS are treated conservatively. The outcome in asymptomatic patients managed conservatively was acceptable. Management in tertiary hospitals is associated with valve intervention. One-year survival was similar with both interventional strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Cells for tissue engineering of cardiac valves.

    PubMed

    Jana, Soumen; Tranquillo, Robert T; Lerman, Amir

    2016-10-01

    Heart valve tissue engineering is a promising alternative to prostheses for the replacement of diseased or damaged heart valves, because tissue-engineered valves have the ability to remodel, regenerate and grow. To engineer heart valves, cells are harvested, seeded onto or into a three-dimensional (3D) matrix platform to generate a tissue-engineered construct in vitro, and then implanted into a patient's body. Successful engineering of heart valves requires a thorough understanding of the different types of cells that can be used to obtain the essential phenotypes that are expressed in native heart valves. This article reviews different cell types that have been used in heart valve engineering, cell sources for harvesting, phenotypic expression in constructs and suitability in heart valve tissue engineering. Natural and synthetic biomaterials that have been applied as scaffold systems or cell-delivery platforms are discussed with each cell type. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Fibrinolytic therapy for mechanical pulmonary valve thrombosis.

    PubMed

    Khajali, Zahra; Mohammadzadeh, Shabnam; Maleki, Majid; Peighambari, Mohammad Mehdi; Sadeghpoor, Anita; Ghavidel, Alireza; Elahi, Behrad; Mirzaaghayan, Mohammadreza

    2015-01-01

    Treatment of prosthetic heart valve thrombosis using intravenous thrombolytics, although an acceptable alternative to surgery, is not complication free, and the literature has a dearth of data on the subject. This study analyzed the results of fibrinolytic treatment (FT) among a single-center group of patients with mechanical pulmonary valve thrombosis. Between 2000 and 2013, 23 consecutive patients with 25 episodes of pulmonary valve thrombosis received FT. The diagnosis of mechanical pulmonary valve thrombosis was established by fluoroscopy and echocardiography. Streptokinase (SK) was used in 24 cases and alteplase in 1 case. The FT was continued a second day for 14 patients (58.3%), a third day for 1 patient, and a fourth day for 1 patient. Echocardiography and fluoroscopy were performed every day until improvement of malfunction was achieved. Of the 23 patients, 19 had complete resolution of hemodynamic abnormalities after FT, 1 had partial resolution, and 2 showed no change. No patient had major complications. Five minor complications were detected, namely, fever, nausea, thrombophlebitis, epistaxi, and pain. Seven patients (30%) experienced recurrence of thrombosis, whereas four patients had surgery (biological pulmonary valve replacement) without re-thrombolytic therapy, one patient was treated with Alteplase, one patient received SK, and one patient received intense anticoagulation using heparin and warfarin. Overall, FT had a success rate of 84%. The results indicate that regardless of the time to pulmonary valve replacement and echocardiographic and fluoroscopic findings, FT was effective in most cases of mechanical pulmonary valve thrombosis. The efficacy increased with second-day thrombolytic therapy. Major complications were not common after lytic therapy for mechanical pulmonary valve thrombosis.

  1. Pros and cons of transcatheter aortic valve implantation (TAVI)

    PubMed Central

    Terré, Juan A.; George, Isaac

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement. PMID:29062739

  2. Airborne asbestos exposures associated with gasket and packing replacement: a simulation study of flange and valve repair work and an assessment of exposure variables.

    PubMed

    Madl, Amy K; Devlin, Kathryn D; Perez, Angela L; Hollins, Dana M; Cowan, Dallas M; Scott, Paul K; White, Katherine; Cheng, Thales J; Henshaw, John L

    2015-02-01

    A simulation study was conducted to evaluate worker and area exposure to airborne asbestos associated with the replacement of asbestos-containing gaskets and packing materials from flanges and valves and assess the influence of several variables previously not investigated. Additionally, potential of take home exposures from clothing worn during the study was characterized. Our data showed that product type, ventilation type, gasket location, flange or bonnet size, number of flanges involved, surface characteristics, gasket surface adherence, and even activity type did not have a significant effect on worker exposures. Average worker asbestos exposures during flange gasket work (PCME=0.166 f/cc, 12-59 min) were similar to average worker asbestos exposures during valve overhaul work (PCME=0.165 f/cc, 7-76 min). Average 8-h TWA asbestos exposures were estimated to range from 0.010 to 0.062 f/cc. Handling clothes worn during gasket and packing replacement activities demonstrated exposures that were 0.71% (0.0009 f/cc 40-h TWA) of the airborne asbestos concentration experienced during the 5 days of the study. Despite the many variables considered in this study, exposures during gasket and packing replacement occur within a relatively narrow range, are below current and historical occupational exposure limits for asbestos, and are consistent with previously published data. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Sleep in octogenarians during the postoperative phase after transcatheter or surgical aortic valve replacement

    PubMed Central

    Amofah, Hege Andersen; Broström, Anders; Fridlund, Bengt; Bjorvatn, Bjørn; Haaverstad, Rune; Hufthammer, Karl Ove; Kuiper, Karel KJ; Ranhoff, Anette Hylen; Norekvål, Tone M

    2015-01-01

    Background: Octogenarians with aortic stenosis are an increasing population of patients admitted for surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI). Although adequate sleep is important after illness and surgery, it has scarcely been studied in the immediate postoperative phase. Aims: To determine and compare the nature of self-reported sleep and insomnia, and recorded sleep–wake patterns in octogenarians during the in-hospital postoperative phase after SAVR or TAVI. Methods: A prospective cohort design was used that included octogenarian patients undergoing SAVR or TAVI at a regional university hospital. Self-reports were used to document sleep and insomnia, and actigraphy was used to record sleep–wake patterns. Data were collected at baseline preoperatively, and then daily for the first five postoperative days. Results: SAVR patients experienced the most insomnia on postoperative nights later in recovery, while TAVI patients experienced the most insomnia on postoperative nights early in recovery. The median total sleep time, as measured by actigraphy, was 6.4 h, and the median sleep efficiency was 79% for the five postoperative nights, but no differences were found between SAVR and TAVI patients on this parameter. All patients slept more during daytime than at night, with SAVR patients having significantly more total sleep hours for all five days than TAVI patients (p < 0.01). Conclusion: Octogenarians with aortic stenosis had disturbed self-reported sleep, increased insomnia, and disturbed sleep–wake patterns postoperatively, resulting in more daytime sleep and inactivity. In patients undergoing SAVR or TAVI, sleep evolves differently during the in-hospital postoperative phase. PMID:26635329

  4. Sleep in octogenarians during the postoperative phase after transcatheter or surgical aortic valve replacement.

    PubMed

    Amofah, Hege Andersen; Broström, Anders; Fridlund, Bengt; Bjorvatn, Bjørn; Haaverstad, Rune; Hufthammer, Karl Ove; Kuiper, Karel Kj; Ranhoff, Anette Hylen; Norekvål, Tone M

    2016-04-01

    Octogenarians with aortic stenosis are an increasing population of patients admitted for surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI). Although adequate sleep is important after illness and surgery, it has scarcely been studied in the immediate postoperative phase. To determine and compare the nature of self-reported sleep and insomnia, and recorded sleep-wake patterns in octogenarians during the in-hospital postoperative phase after SAVR or TAVI. A prospective cohort design was used that included octogenarian patients undergoing SAVR or TAVI at a regional university hospital. Self-reports were used to document sleep and insomnia, and actigraphy was used to record sleep-wake patterns. Data were collected at baseline preoperatively, and then daily for the first five postoperative days. SAVR patients experienced the most insomnia on postoperative nights later in recovery, while TAVI patients experienced the most insomnia on postoperative nights early in recovery. The median total sleep time, as measured by actigraphy, was 6.4 h, and the median sleep efficiency was 79% for the five postoperative nights, but no differences were found between SAVR and TAVI patients on this parameter. All patients slept more during daytime than at night, with SAVR patients having significantly more total sleep hours for all five days than TAVI patients (p < 0.01). Octogenarians with aortic stenosis had disturbed self-reported sleep, increased insomnia, and disturbed sleep-wake patterns postoperatively, resulting in more daytime sleep and inactivity. In patients undergoing SAVR or TAVI, sleep evolves differently during the in-hospital postoperative phase. © The European Society of Cardiology 2015.

  5. Clinical and hemodynamic results after direct transcatheter aortic valve replacement versus pre-implantation balloon aortic valvuloplasty: A case-matched analysis.

    PubMed

    Ferrera, Carlos; Nombela-Franco, Luis; Garcia, Eulogio; Jimenez-Quevedo, Pilar; Biagioni, Corina; Gonzalo, Nieves; Nuñez-Gil, Ivan; Viana-Tejedor, Ana; Salinas, Pablo; Alberto de Agustin, Jose; Almeria, Carlos; Islas, Fabian; Perez de Isla, Leopoldo; Fernandez-Perez, Cristina; Escaned, Javier; Fernández-Ortiz, Antonio; Macaya, Carlos

    2017-11-01

    To evaluate the safety and midterm hemodynamic results of direct transcatheter aortic valve replacement (TAVR) without pre-implantation balloon aortic valvuloplasty (BAV). BAV was considered a mandatory previous step in TAVR procedures. A total of 339 consecutive patients who underwent transfemoral TAVR were prospectively selected. A 1:1 matching was conducted, pairing age, prosthesis type (self-expandable or balloon expandable) and size, and valve calcification grade (48% with moderate to severe valve calcification). Finally, 102 pairs (102 patients with previous BAV and 102 without BAV) were obtained. Direct TAVR was feasible in all patients without any crossover to BAV group. Device success was achieved in 91.2% and 90.2% of cases in direct TAVR and pre-BAV groups (P = 0.810), respectively, without any differences in balloon postdilation rate and residual aortic regurgitation. The amount of contrast agent, acute kidney injury and myocardial injury was significantly lower in the direct implantation group (P < 0.05). No differences were found in 30-day and 1-year mortality between both groups (4.9% vs. 9.8%, P = 0.177 and 14.0% vs. 23.8%, P = 0.771, respectively). Hemodynamic parameters remained stable after 1-year follow-up in both groups. Direct transfemoral TAVR without prior BAV was safe in patients with calcified severe aortic stenosis. Pre-implantation BAV could be omitted in patients undergoing TAVR, without influence in procedure success rate, and subsequent patients' clinical course and valve hemodynamic performance. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    PubMed

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  7. Design considerations and quantitative assessment for the development of percutaneous mitral valve stent.

    PubMed

    Kumar, Gideon Praveen; Cui, Fangsen; Phang, Hui Qun; Su, Boyang; Leo, Hwa Liang; Hon, Jimmy Kim Fatt

    2014-07-01

    Percutaneous heart valve replacement is gaining popularity, as more positive reports of satisfactory early clinical experiences are published. However this technique is mostly used for the replacement of pulmonary and aortic valves and less often for the repair and replacement of atrioventricular valves mainly due to their anatomical complexity. While the challenges posed by the complexity of the mitral annulus anatomy cannot be mitigated, it is possible to design mitral stents that could offer good anchorage and support to the valve prosthesis. This paper describes four new Nitinol based mitral valve designs with specific features intended to address migration and paravalvular leaks associated with mitral valve designs. The paper also describes maximum possible crimpability assessment of these mitral stent designs using a crimpability index formulation based on the various stent design parameters. The actual crimpability of the designs was further evaluated using finite element analysis (FEA). Furthermore, fatigue modeling and analysis was also done on these designs. One of the models was then coated with polytetrafluoroethylene (PTFE) with leaflets sutured and put to: (i) leaflet functional tests to check for proper coaptation of the leaflet and regurgitation leakages on a phantom model and (ii) anchorage test where the stented valve was deployed in an explanted pig heart. Simulations results showed that all the stents designs could be crimped to 18F without mechanical failure. Leaflet functional test results showed that the valve leaflets in the fabricated stented valve coapted properly and the regurgitation leakage being within acceptable limits. Deployment of the stented valve in the explanted heart showed that it anchors well in the mitral annulus. Based on these promising results of the one design tested, the other stent models proposed here were also considered to be promising for percutaneous replacement of mitral valves for the treatment of mitral

  8. Impact of bendopnea on postoperative outcomes in patients with severe aortic stenosis undergoing aortic valve replacement.

    PubMed

    Dominguez-Rodriguez, Alberto; Thibodeau, Jennifer T; Ayers, Colby R; Jimenez-Sosa, Alejandro; Garrido, Pilar; Montoto, Javier; Prada-Arrondo, Pablo C; Abreu-Gonzalez, Pedro; Drazner, Mark H

    2018-06-02

    Bendopnea is a recently described symptom of advanced heart failure. Its prevalence and prognostic utility in other cardiac conditions are unknown. We prospectively enrolled 108 consecutive patients (75 ± 3 years, 68% men) with severe symptomatic aortic stenosis referred for surgical aortic valve replacement (SAVR). Preoperatively, patients were tested for bendopnea, which was considered to be present when dyspnoea occurred within 30 s of bending forward. Univariable and stepwise multivariable analyses tested the association of bendopnea with preoperative echocardiographic parameters and postoperative clinical outcomes. Bendopnea was present in 46 of 108 (42%) patients. The mean time of onset was 10.5 ± 3.4 s. Bendopnea was associated with higher estimated pulmonary artery systolic pressures [51 (11) mmHg vs 40 (11) mmHg), P < 0.0001], smaller aortic valve area [0.66 (0.16) cm2 vs 0.76 (0.13) cm2, P = 0.0006] and longer duration of mechanical ventilation (P = 0.002) and length of stay in the hospital (P = 0.007). Following SAVR, in-hospital mortality in those with bendopnea versus those without bendopnea was 13% vs 3% (P = 0.07). In multivariable analysis, bendopnea was associated with duration of mechanical ventilation (parameter estimate 2.4, P < 0.0001) and length of stay in the hospital (parameter estimate 10.2, P ≤ 0.0001). Bendopnea was present in a sizeable minority of patients (42%) with severe aortic stenosis referred for SAVR. Bendopnea was associated with higher pulmonary artery systolic pressure and smaller aortic valve area preoperatively and with longer duration of mechanical ventilation and length of hospitalization postoperatively. These data suggest that bendopnea provides prognostic information in patients with severe aortic stenosis undergoing SAVR.

  9. Transcatheter vs Surgical Aortic Valve Replacement for Aortic Stenosis in Low-Intermediate Risk Patients: A Meta-analysis.

    PubMed

    Tam, Derrick Y; Vo, Thin Xuan; Wijeysundera, Harindra C; Ko, Dennis T; Rocha, Rodolfo Vigil; Friedrich, Jan; Fremes, Stephen E

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has emerged as the treatment of choice for patients with severe aortic stenosis at high surgical risk; the role of TAVR compared with surgical aortic valve replacement (SAVR) in the low-intermediate surgical risk population remains uncertain. Our primary objective was to determine differences in 30-day and late mortality in patients treated with TAVR compared with SAVR at low-intermediate risk (Society of Thoracic Surgeons Predicted Risk of Mortality < 10%). Medline and Embase were searched from 2010 to March 2017 for studies that compared TAVR with SAVR in the low-intermediate surgical risk population, restricted to randomized clinical trials and matched observational studies. Two investigators independently abstracted the data and a random effects meta-analysis was performed. Four randomized clinical trials (n = 4042) and 9 propensity score-matched observational studies (n = 4192) were included in the meta-analysis (n = 8234). There was no difference in 30-day mortality between TAVR and SAVR (3.2% vs 3.1%, pooled risk ratio: 1.02; 95% confidence interval, 0.80-1.30; P = 0.89; I 2  = 0%) or mortality at a median of 1.5-year follow-up (incident rate ratio: 1.01; 95% confidence interval, 0.90-1.15; P = 0.83; I 2  = 0%). There was a higher risk of pacemaker implantation and greater than trace aortic insufficiency in the TAVR group whereas the risk of early stroke, atrial fibrillation, acute kidney injury, cardiogenic shock, and major bleeding was higher in the SAVR group. Although there was no difference in 30-day and late mortality, the rate of complications differed between TAVR and SAVR in the low-intermediate surgical risk population. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. Aspirin Versus Aspirin Plus Clopidogrel as Antithrombotic Treatment Following Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve: The ARTE (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation) Randomized Clinical Trial.

    PubMed

    Rodés-Cabau, Josep; Masson, Jean-Bernard; Welsh, Robert C; Garcia Del Blanco, Bruno; Pelletier, Marc; Webb, John G; Al-Qoofi, Faisal; Généreux, Philippe; Maluenda, Gabriel; Thoenes, Martin; Paradis, Jean-Michel; Chamandi, Chekrallah; Serra, Vicenç; Dumont, Eric; Côté, Mélanie

    2017-07-10

    The aim of this study was to compare aspirin plus clopidogrel with aspirin alone as antithrombotic treatment following transcatheter aortic valve replacement (TAVR) for the prevention of ischemic events, bleeding events, and death. Few data exist on the optimal antithrombotic therapy following TAVR. This was a randomized controlled trial comparing aspirin (80 to 100 mg/day) plus clopidogrel (75 mg/day) (dual antiplatelet therapy [DAPT]) versus aspirin alone (single-antiplatelet therapy [SAPT]) in patients undergoing TAVR with a balloon-expandable valve. The primary endpoint was the occurrence of death, myocardial infarction (MI), stroke or transient ischemic attack, or major or life-threatening bleeding (according to Valve Academic Research Consortium 2 definitions) within the 3 months following the procedure. The trial was prematurely stopped after the inclusion of 74% of the planned study population. A total of 222 patients were included, 111 allocated to DAPT and 111 to SAPT. The composite of death, MI, stroke or transient ischemic attack, or major or life-threatening bleeding tended to occur more frequently in the DAPT group (15.3% vs. 7.2%, p = 0.065). There were no differences between groups in the occurrence of death (DAPT, 6.3%; SAPT, 3.6%; p = 0.37), MI (DAPT, 3.6%; SAT, 0.9%; p = 0.18), or stroke or transient ischemic attack (DAPT, 2.7%; SAPT, 0.9%; p = 0.31) at 3 months. DAPT was associated with a higher rate of major or life-threatening bleeding events (10.8% vs. 3.6% in the SAPT group, p = 0.038). There were no differences between groups in valve hemodynamic status post-TAVR. This small trial showed that SAPT (vs. DAPT) tended to reduce the occurrence of major adverse events following TAVR. SAPT reduced the risk for major or life-threatening events while not increasing the risk for MI or stroke. Larger studies are needed to confirm these results. (Aspirin Versus Aspirin + Clopidogrel Following Transcatheter Aortic Valve Implantation: The ARTE

  11. Echocardiographic Assessment of Heart Valve Prostheses

    PubMed Central

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  12. [Mitral valve endocarditis after Turkish "Festival of Sacrifice"].

    PubMed

    Blaich, A; Fasel, D; Kaech, C; Frei, R

    2011-09-01

    Erysipelothrix rhusiopathiae is the causative agent of swine erysipelas. Systemic infections caused by E. rhusiopathiae are rare, but often (90%) associated with endocarditis. In about 60% of cases endocarditis develops on normal heart valves, and despite appropriate antibiotic therapy about one-third of the patients requires valve replacement. We report the case of a housewife, who developed a mitral valve endocarditis due to E. rhusiopathiae after preparing meat for the Turkish "Festival of Sacrifice".

  13. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    PubMed Central

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  14. Fluid dynamic characterization of a polymeric heart valve prototype (Poli-Valve) tested under continuous and pulsatile flow conditions.

    PubMed

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D; Costantino, Maria Laura

    2015-11-01

    Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.

  15. IL-10 and ET-1 as biomarkers of rheumatic valve disease

    PubMed Central

    Leão, Sydney Correia; Lima, Maria Regina Menezes; do Nascimento, Hertaline Menezes; Octacilio-Silva, Shirlei; Rodrigues, Tania Maria de Andrade

    2014-01-01

    Objective To evaluate the immunological profile and gene expression of endothelin-1 (ET-1) in mitral valves of patients with rheumatic fever originated from a reference service in cardiovascular surgery. Methods This was a quantitative, observational and cross-sectional study. Thirty-five subjects (divided into four groups) participated in the study, 25 patients with chronic rheumatic heart disease and ten control subjects. The mean age of the sample studied was 34.5 years. Seventeen of them (48.58%) were male and 18 (51.42%) were female. Inflammatory cytokines (TNF-α, IL-4 and IL-10) were measured and ten mitral valves of patients who underwent first valve replacement were collected for determination of gene expression of endothelin-1 by real time PCR. Results Among the groups studied (patients vs. controls), there was a statistically significant difference in IL-10 levels (P=0.002), and no differences in other cytokines. Expression of endothelin-1 was observed in 70% of samples. Quantitatively, average of ET-1 expression was 62.85±25.63%. Conclusion Inflammatory cytokine IL-10 participates in the maintenance of chronicity of rheumatic fever in patients who underwent valve replacement and those who are undergoing medical treatment. The expression of endothelin-1 in heart valve lesions in patients undergoing mitral valve replacement confirms its association with inflammatory activity in rheumatic fever. PMID:24896159

  16. Systemic vascular load in calcific degenerative aortic valve stenosis: insight from percutaneous valve replacement.

    PubMed

    Yotti, Raquel; Bermejo, Javier; Gutiérrez-Ibañes, Enrique; Pérez del Villar, Candelas; Mombiela, Teresa; Elízaga, Jaime; Benito, Yolanda; González-Mansilla, Ana; Barrio, Alicia; Rodríguez-Pérez, Daniel; Martínez-Legazpi, Pablo; Fernández-Avilés, Francisco

    2015-02-10

    Systemic arterial load impacts the symptomatic status and outcome of patients with calcific degenerative aortic stenosis (AS). However, assessing vascular properties is challenging because the arterial tree's behavior could be influenced by the valvular obstruction. This study sought to characterize the interaction between valvular and vascular functions in patients with AS by using transcatheter aortic valve replacement (TAVR) as a clinical model of isolated intervention. Aortic pressure and flow were measured simultaneously using high-fidelity sensors in 23 patients (mean 79 ± 7 years of age) before and after TAVR. Blood pressure and clinical response were registered at 6-month follow-up. Systolic and pulse arterial pressures, as well as indices of vascular function (vascular resistance, aortic input impedance, compliance, and arterial elastance), were significantly modified by TAVR, exhibiting stiffer vascular behavior post-intervention (all, p < 0.05). Peak left ventricular pressure decreased after TAVR (186 ± 36 mm Hg vs. 162 ± 23 mm Hg, respectively; p = 0.003) but remained at >140 mm Hg in 70% of patients. Wave intensity analysis showed abnormally low forward and backward compression waves at baseline, increasing significantly after TAVR. Stroke volume decreased (-21 ± 19%; p < 0.001) and correlated with continuous and pulsatile indices of arterial load. In the 48 h following TAVR, a hypertensive response was observed in 12 patients (52%), and after 6-month follow-up, 5 patients required further intensification of discharge antihypertensive therapy. Vascular function in calcific degenerative AS is conditioned by the upstream valvular obstruction that dampens forward and backward compression waves in the arterial tree. An increase in vascular load after TAVR limits the procedure's acute afterload relief. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Predictive factor of secondary tricuspid regurgitation after aortic valve replacement for aortic stenosis: the importance of myocardial hypertrophy and diastolic dysfunction.

    PubMed

    Igarashi, Takashi; Tanji, Masahiro; Takahashi, Koki; Ishida, Keiichi; Sasaki, Satomi; Yokoyama, Hitoshi

    2017-05-01

    The aim of this study is to determine the predictors of secondary tricuspid regurgitation after aortic valve replacement for aortic stenosis. Seventy-one patients, who underwent aortic valve replacement for aortic stenosis at our institute from January 2006 to July 2011, were divided into two groups: an STR group, which included 15 patients with moderate or greater than moderate secondary tricuspid regurgitation at a follow-up visit and a control group. Echocardiography was performed before surgery, at discharge, and at a late follow-up visit (mean follow-up 36 ± 19 months, range 0-77). Preoperatively, the number of women (p < .01), body surface area (p < .001), and relative wall thickness (0.60 ± 0.15 vs 0.71 ± 0.13, p = .022) showed significant differences between the two groups. At a follow-up visit, moderate or severe mitral regurgitation (p = .0001) and severe diastolic dysfunction (p = .003) showed significant differences between the two groups. In the Cox regression analysis, moderate or severe mitral regurgitation at follow-up (p = .038, hazard ratio 4.394, 95% CI 1.085-17.791) was the only independent predictor of secondary tricuspid regurgitation. This study suggested that preoperative concentric myocardial hypertrophy and diastolic dysfunction were associated with development of the secondary tricuspid regurgitation at late follow-up.

  18. Clinical Relevance of Baseline TCP in Transcatheter Aortic Valve Replacement.

    PubMed

    Sannino, Anna; Stoler, Robert C; Hebeler, Robert F; Szerlip, Molly; Mack, Michael J; Grayburn, Paul A

    2017-10-01

    To investigate the influence of baseline thrombocytopenia (TCP) on short-term and long-term outcomes after transcatheter aortic valve replacement (TAVR). A total of 732 consecutive patients with severe, symptomatic aortic stenosis undergoing TAVR from January 2012 to December 2015 were included. Primary outcomes of interest were the relationship of baseline TCP with 30-day and 1-year all-cause mortality. Secondary outcomes of interest were procedural complications and in-hospital mortality in the same subgroups. The prevalence of TCP (defined as platelet count <150 × 109/L) at baseline was 21.9%, of whom 4.0% had moderate/severe TCP (defined as platelet count <100 × 109/L). Compared to no or mild TCP, moderate/severe TCP at baseline was associated with a significantly higher 30-day mortality (23.3% vs 2.3% and 3.1%, respectively; P<.001) and 1-year mortality (40.0% vs 8.3% and 13.4%, respectively; P<.001). In Cox regression analysis, moderate/severe baseline TCP was an independent predictor of 30-day and 1-year mortality (hazard ratio [HR], 13.18; 95% confidence interval [CI], 4.49-38.64; P<.001 and HR, 5.90; 95% CI, 2.68-13.02; P<.001, respectively). In conclusion, baseline TCP is a strong predictor of mortality in TAVR patients, possibly identifying a specific subgroup of frail patients; therefore, it should be taken into account when addressing TAVR risk.

  19. Outcomes of transcatheter aortic valve replacement using a minimalist approach.

    PubMed

    Gurevich, Sergey; Oestreich, Brett; Kelly, Rosemary F; Mbai, Mackenzie; Bertog, Stefan; Ringsred, Karen; Lawton, Annette; Thooft, Brenda; Wagner, Julie; Garcia, Santiago

    2018-03-01

    Transcatheter Aortic Valve Replacement (TAVR) is increasingly performed using a minimalist approach under monitored anesthesia care (MAC). The safety of this approach remains controversial and adoption has been low in the US. The study cohort was comprised of 130 patients (98% male) who underwent TAVR between 4/2015 and 4/2017 at the Minneapolis VA. We compared the outcomes of 81 patients who underwent TAVR using a standard approach (standard TAVR) and 49 who underwent TAVR using a minimalist approach (minimalist TAVR). Outcome measures included device and procedural success, procedural efficiency, length of intensive care unit (ICU) and hospital stay, procedural complications and hospital readmissions. Mean age was 80 (±9) years and median (IQR) STS score was 5 (4-6). Access included transfemoral (n = 111, 85%) and alternative (n = 19, 15%). Minimalist TAVR was associated with reduced procedural time: median 101 min (IQR: 78-135) versus 127 min (IQR: 97-182, p = 0.03), fluoroscopy time: median 18 min (IQR: 12-26) versus 24 min (IQR: 16-38), p = 0.001), contrast volume 90 ml (IQR: 70-120 ml) versus 140 ml (IQR: 86-213 ml, p < 0.001). A minimalistic approach to TAVR is associated with improved procedural efficiency and reduced length of stay without compromising procedural success or clinical outcomes. Published by Elsevier Inc.

  20. Dabigatran Versus Warfarin After Bioprosthesis Valve Replacement for the Management of Atrial Fibrillation Postoperatively: DAWA Pilot Study.

    PubMed

    Durães, André Rodrigues; de Souza Roriz, Pollianna; de Almeida Nunes, Bianca; Albuquerque, Felipe Pinho E; de Bulhões, Fábio Vieira; de Souza Fernandes, Andre Mauricio; Aras, Roque

    2016-06-01

    Dabigatran is a direct thrombin inhibitor shown to be an effective alternative to warfarin in patients with non-valvular atrial fibrillation (AF). We evaluated the use of dabigatran in patients with bioprosthetic mitral and/or aortic valve replacement and AF. We selected 34 and randomized 27 patients in a 1:1 ratio to receive dabigatran or warfarin. The primary endpoint was the presence of a new intracardiac thrombus at 90 days, by transesophageal echocardiogram (TEE). Secondary endpoints included the development of dense spontaneous echo contrast (SEC) and incidence of stroke (ischemic or hemorrhagic), myocardium infarction, valve thrombosis and peripheral embolic events. The trial was terminated prematurely because of low enrollment. There were 27 patients in total: 15 patients placed in the dabigatran group and 12 in the warfarin group. After 90 days, one patient (8.3 %) in the warfarin group and none in the dabigatran group had developed a new intracardiac thrombus. In the dabigatran group, two patients (13.3 %) developed dense SEC versus one patient (8.3 %) in the warfarin group. In the warfarin group, one patient (8.3 %) presented ischemic stroke, and none did in the dabigatran group. We observed no cases of hemorrhagic stroke, valve thrombosis, embolic events or myocardial infarction in either group throughout the study. However, one patient (6.7 %) in the dabigatran group had a fully recovered transient ischemic attack and one patient in the warfarin group died of heart failure. The use of dabigatran appears to be similar to warfarin in preventing the formation of intracardiac thrombus. Clinicaltrials.gov NCT01868243.

  1. Outcomes in 937 Intermediate-Risk Patients Undergoing Surgical Aortic Valve Replacement in PARTNER-2A.

    PubMed

    Thourani, Vinod H; Forcillo, Jessica; Szeto, Wilson Y; Kodali, Susheel K; Blackstone, Eugene H; Lowry, Ashley M; Semple, Marie; Rajeswaran, Jeevanantham; Makkar, Raj R; Williams, Mathew R; Bavaria, Joseph E; Herrmann, Howard C; Maniar, Hersh S; Babaliaros, Vasilis C; Smith, Craig R; Trento, Alfredo; Corso, Paul J; Pichard, Augusto D; Miller, D Craig; Svensson, Lars G; Kapadia, Samir; Ailawadi, Gorav; Suri, Rakesh M; Greason, Kevin L; Hahn, Rebecca T; Jaber, Wael A; Alu, Maria C; Leon, Martin B; Mack, Michael J

    2018-05-01

    The Placement of Aortic Transcatheter Valves 2A (PARTNER-2A) randomized trial compared outcomes of transfemoral transcatheter and surgical aortic valve replacement (SAVR) in intermediate-risk patients with severe aortic stenosis. The purpose of the present study was to perform an in-depth analysis of outcomes after SAVR in the PARTNER-2A trial. From January 2012 to January 2014, 937 patients underwent SAVR at 57 centers. Mean age was 82 ± 6.7 years and 55% were men. Less-invasive operations were performed in 140 patients (15%) and concomitant procedures in 198 patients (21%). Major outcomes and echocardiograms were adjudicated by an independent events committee. Follow-up was 94% complete to 2 years. Operative mortality was 4.1% (n = 38, Society of Thoracic Surgeons predicted risk of mortality: 5.2% ± 2.3%), observed to expected ratio (O/E) was 0.8, and in-hospital stroke was 5.4% (n = 51), twice expected. Aortic clamp and bypass times were 75 ± 30 minutes and 104 ± 46 minutes, respectively. Patients having severe prosthesis-patient mismatch (n = 260, 33%) had similar survival to patients without (p > 0.9), as did patients undergoing less-invasive SAVR (p = 0.3). Risk factors for death included cachexia (p = 0.004), tricuspid regurgitation (p = 0.01), coronary artery disease (p = 0.02), preoperative atrial fibrillation (p = 0.001), higher white blood cell count (p < 0.0001), and lower hemoglobin (p = 0.0002). In this adjudicated prospective study, SAVR in intermediate-risk patients had excellent results at 2 years. However, there were more in-hospital strokes than expected, most likely attributable to mandatory neurologic assessment after the procedure. No pronounced structural valve deterioration was found during 2-year follow-up. Continued long-term surveillance remains important. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Severe bioprosthetic mitral valve stenosis in pregnancy.

    PubMed

    Munoz-Mendoza, Jerson; Pinto Miranda, Veronica; Tanawuttiwat, Tanyanan; Badiye, Amit; Chaparro, Sandra V

    2016-01-01

    A 21-year-old woman in the 16th week of pregnancy was admitted due to acute presentation of severe exertional dyspnea. She had undergone mitral valve replacement (MVR) with bioprosthetic valve for infective endocarditis 2 years ago. She developed congestive heart failure from mitral bioprosthetic valve stenosis due to early structural valve deterioration. She also had severe pulmonary hypertension and underwent a redo MVR using a mechanical valve prosthesis with good maternal outcome but fetal demise. This report brings up the debate about what type of valve should be used in women in reproductive age, and discusses the management of severe mitral stenosis and stenosis of a bioprosthetic valve during pregnancy. Surgical options can almost always be delayed until fetal maturity is achieved and a simultaneous cesarean section can be performed. However, under certain circumstances when the maternal welfare is in jeopardy the surgical intervention is mandatory even before the fetus reaches viability.

  3. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair.

    PubMed

    Yoo, Byung Won; Park, Han Ki

    2013-06-01

    Repair of tetralogy of Fallot (TOF) has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS) and free pulmonary regurgitation (PR) at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT) reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR) increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF.

  4. [Status of aortic valve reconstruction and Ross operation in aortic valve diseases].

    PubMed

    Sievers, Hans H

    2002-08-01

    if these are progressive and combined with aortic insufficiency. ROSS-OPERATION: The Ross-Operation includes the replacement of the diseased aortic valve with the pulmonary autograft and reconstruction of the right ventricular outflow tract using a homograft. The hemodynamic results are excellent regarding the autograft and also the clinical results with very low thromboembolic risk and acceptable reoperation rate. This method is especially indicated for active young patients, women, who desire children, athletes and patients in general, who like to avoid long-term anticoagulation. In some cases the homograft may develop a dysfunction predominantly a pulmonary stenosis requiring reoperation. In the author's series of 245 Ross-operations in 12 years the homograft had to be replaced in 4 cases without letality. Innovative, decellularized homografts with the potential to repopulate with autologeous cells show promising results after 1 year of clinical implantation without signs of antibody development. Probably these tissue-engineered modification may improve the homograft results. The reconstructive techniques of the aortic valve and the Ross-operation have a certain risk of reoperation that must be weighed against the advantages of very low hospital and late valve related death, excellent hemodynamics, very low risk of macro- and microembolism as well as bleeding, lack of long-term anticoagulation and unrestricted life-style.

  5. Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies.

    PubMed

    Philip, Femi; Faza, Nadine Nadar; Schoenhagen, Paul; Desai, Milind Y; Tuzcu, E Murat; Svensson, Lars G; Kapadia, Samir R

    2015-08-01

    Patients with severe aortic stenosis due to BAV are excluded from transcatheter aortic valve replacement (TAVR) due to concern for asymmetric expansion and valve dysfunction. We sought to characterize the aortic root and annulus in bicuspid aortic valve (BAV) and tricuspid aortic valves (TAV). We identified patients with severe AS who underwent multi-detector computed tomographic (MDCT) imaging prior to surgical aortic valve replacement (SAVR, n = 200) for BAV and TAVR (n = 200) for TAV from 2010 to 2013. The presence of a BAV was confirmed on surgical and pathological review. Annulus measurements of the basal ring (short- and long-axis, area-derived diameter), coronary ostia height, sinus area (SA), sino-tubular junction area (STJ), calcification and eccentricity index (EI, 1-short axis/long axis) were made. Patients with TAV were older (78.8 years vs. 57.8 years, P = 0.04) than those with BAV. The aortic annulus area (5.21 ± 2.1 cm(2) vs. 4.63 ± 2.0 cm(2) , P = 0.0001), sinus of Valsalva diameter (3.7 ± 0.9 cm vs. 3.1 ± 0.1 cm, P = 0.001) and ascending aorta diameter (3.5 ± 0.7 cm vs. 2.97 ± 0.6 cm, P = 0.001) were significantly larger with BAV. Bicuspid aortic annuli were significantly less elliptical (EI, 1.24 ± 0.1 vs. 1.29 ± 0.1, P = 0.006) and more circular (39% vs. 4%, P < 0.001) compared to the TAV annulus. There was more eccentric annular calcification in BAV vs. TAV (68% vs. 32%, P < 0.001). The mean distance from the aortic annulus to the left main coronary ostium was less than the right coronary ostium. Less than 10% of the BAV annuli would not fit a currently available valved stents. Bicuspid aortic valves have a larger annulus size, sinus of Valsalva and ascending aorta dimensions. In addition, the BAV aortic annuli appear circular and most will fit currently available commercial valved stents. © 2015 Wiley Periodicals, Inc.

  6. Death and Dialysis After Transcatheter Aortic Valve Replacement: An Analysis of the STS/ACC TVT Registry.

    PubMed

    Hansen, James W; Foy, Andrew; Yadav, Pradeep; Gilchrist, Ian C; Kozak, Mark; Stebbins, Amanda; Matsouaka, Roland; Vemulapalli, Sreekanth; Wang, Alice; Wang, Dee Dee; Eng, Marvin H; Greenbaum, Adam B; O'Neill, William O

    2017-10-23

    The authors sought to elucidate the true incidence of renal replacement therapy (RRT) after transcatheter aortic valve replacement (TAVR). There is a wide discrepancy in the reported rate of RRT after TAVR (1.4% to 40%). The true incidence of RRT after TAVR is unknown. The STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) registry was linked to the Centers for Medicare & Medicaid database to identify all patients that underwent TAVR from November 2011 through September 2015 and their outcomes. The authors compared rates of death, new RRT, and a composite of both as a function of pre-procedure glomerular filtration rate (GFR), both in stages of chronic kidney disease (CKD), as well as on a continuous scale. Pre-procedure GFR is associated with the risk of death and new RRT after TAVR when GFR is <60 ml/min/m 2 , and increases significantly when GFR falls below 30 ml/min/m 2 . Incremental increases in GFR of 5 ml/min/m 2 were statistically significant (unadjusted hazard ratio: 0.71; p < 0.001) at 30 days, and continued to be significant at 1 year when pre-procedure GFR was <60 ml/min/m 2 . One in 3 CKD stage 4 patients will be dead within 1 year, with 14.6% (roughly 1 in 6) requiring dialysis. In CKD stage 5, more than one-third of patients will require RRT within 30 days; nearly two-thirds will require RRT at 1 year. In both unadjusted and adjusted analysis, pre-procedural GFR was associated with the outcomes of death and new RRT. Increasing CKD stage leads to an increased risk of death and/or RRT. Continuous analysis showed significant differences in outcomes in all levels of CKD when GFR was <60 ml/min/m 2 . Pre-procedure GFR should be considered when selecting CKD patients for TAVR. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis.

    PubMed

    Wijesinghe, Namal; Ye, Jian; Rodés-Cabau, Josep; Cheung, Anson; Velianou, James L; Natarajan, Madhu K; Dumont, Eric; Nietlispach, Fabian; Gurvitch, Ronen; Wood, David A; Tay, Edgar; Webb, John G

    2010-11-01

    We evaluated transcatheter aortic valve implantation (TAVI) in high-risk patients with bicuspid aortic valve (BAV) stenosis. TAVI shows promise in the treatment of severe stenosis of triscupid aortic valves, especially in high-risk patients. However, BAV stenosis has been considered a contraindication to TAVI. Eleven patients (age 52 to 90 years) with symptomatic severe BAV stenosis underwent TAVI at 3 Canadian tertiary hospitals between May 2006 and April 2010. All patients were considered high risk for surgical aortic valve replacement. Edwards-SAPIEN transcatheter heart valves (Edwards Lifesciences, Inc., Irvine, California) were used. Transfemoral or transapical access was selected, depending on the adequacy of femoral access. Access was transfemoral in 7 patients and transapical in 4 patients. There were no intraprocedural complications. Significant symptomatic and hemodynamic improvement was observed in 10 of 11 patients. Baseline aortic valve area of 0.65 ± 0.17 cm(2) and mean transaortic pressure gradient of 41 ± 22.4 mm Hg were improved to 1.45 ± 0.3 cm(2) and 13.4 ± 5.7 mm Hg, respectively. Two patients had moderate perivalvular leaks. At the 30-day follow-up there were 2 deaths due to multisystem failure in 2 transapical patients. In 1 patient an undersized, suboptimally positioned, unstable valve required late conversion to open surgery. TAVI in selected high-risk patients with severe BAV stenosis can be successfully performed with acceptable clinical outcomes but will require further evaluation. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart Valve

    PubMed Central

    Claiborne, Thomas E.; Sheriff, Jawaad; Kuetting, Maximilian; Steinseifer, Ulrich; Slepian, Marvin J.; Bluestein, Danny

    2013-01-01

    Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the

  9. Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator

    NASA Technical Reports Server (NTRS)

    Ramspacher, Daniel J. (Inventor); Richard, James A. (Inventor)

    2017-01-01

    A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.

  10. Valve leakage inspection, testing, and maintenance process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aikin, J.A.; Reinwald, J.W.

    1989-01-01

    Atomic Energy of Canada Limited-Research Company (AECL-RC), Chalk River, has more than 50 person-years dedicated toward the leak-free valve. In the early 1970s, the Chalk River Nuclear Laboratories (CRNL) developed valve stem live-loading and recently completed the packing tests for the Electric Power Research Institute (EPRI)-funded Valve Packing Improvement Study. Current safety concerns with asbestos-based valve packings and the difficulty in removing newer graphite packings prompted CRNL to investigate methods to improve valve repacking procedures. The present practice of valve packing replacement is very labor-intensive, requiring use of hand tools such as corkscrew devices and special packing picks. Use ofmore » water jets to cut or fragment the packing for withdrawal from the stuffing box does improve the process, but removal of the lantern or junk rings is still difficult. To address these problems, AECL-RC has developed a unique valve maintenance process designed to reduce person-rem exposures, the risk of scoring the stem or stuffing box, and maintenance costs and to improve the engineering quality of valve repair.« less

  11. [Minor strut fracture of the Björk-Shiley mitral valve].

    PubMed

    Sugita, T; Yasuda, R; Watarida, S; Onoe, M; Tabata, R; Mori, A

    1990-06-01

    In May, 1982, a 49-year-old man underwent mitral valve replacement (MVR) in our hospital with a 31 mm Björk-Shiley prosthesis for mitral regurgitation. He had been doing well until his episode of palpitation and dyspnea of sudden onset, and was transferred to our ICU with severe cardiogenic shock in Aug, 1986. Chest X-ray film revealed pulmonary edema and breakage of the valve with migration of the disc and the minor strut of the prosthesis. He was operated upon 5 hours after the onset of his complaints. The minor strut was removed from the left upper pulmonary vein and mitral valve re-replacement was done with a 29 mm Björk-Shiley Monostrut valve. The disc which had dislocated into the abdominal aorta was also recovered on the twenty-third post operative day. His postoperative course was uneventful. Immediate diagnosis and subsequent re-operation is absolute indication for rescue from acute cardiac failure due to mechanical failure of any prosthetic valve.

  12. Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves.

    PubMed

    Valente, M; Minarini, M; Maizza, A F; Bortolotti, U; Thiene, G

    1992-01-01

    Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Transcatheter aortic valve replacement in patients with severe aortic stenosis who are at high risk for surgical complications: summary assessment of the California Technology Assessment Forum.

    PubMed

    Tice, Jeffrey A; Sellke, Frank W; Schaff, Hartzell V

    2014-08-01

    The California Technology Assessment Forum is dedicated to assessment and public reporting of syntheses of available data on medical technologies. In this assessment, transcatheter aortic valve replacement (TAVR) was evaluated for patients with severe aortic stenosis (AS) who are at high risk for complications. In this assessment, 5 criteria were used: Regulatory approval, sufficient scientific evidence to allow conclusions on effectiveness, evidence that the technology improves net health outcomes, evidence that the technology is as beneficial as established methods, and availability of the technology outside investigational settings. In this assessment, all 5 criteria were judged to have been met. The primary benefit of TAVR is the ability to treat AS in patients who would otherwise be ineligible for surgical aortic valve replacement. It may also be useful for patients at high surgical risk by potentially reducing periprocedural complications and avoiding the morbidity and recovery from undergoing heart surgery. Potential harms include the need for conversion to an open procedure, perioperative death, myocardial infarction, stroke, bleeding, valve embolization, aortic regurgitation, heart block that requires a permanent pacemaker, renal failure, pulmonary failure, and major vascular complications such as cardiac perforation or arterial dissection. Potential long-term harms include death, stroke, valve failure or clotting, and endocarditis. As highlighted at the February 2012 California Technology Assessment Forum meeting, the dispersion of this technology to new centers across the United States must proceed with careful thought given to training and proctoring multidisciplinary teams to become new centers of excellence. TAVR is a potentially lifesaving procedure that may improve quality of life for patients at high risk for surgical AVR. However, attention needs to be paid to appropriate patient selection, their preoperative evaluation, surgical techniques, and

  14. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    PubMed

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  15. Minimally invasive aortic valve replacement surgery through lower half sternotomy

    PubMed Central

    Fenton, James R.

    2013-01-01

    Less invasive approaches to aortic valve surgery frequently rely upon the development of new technology and instrumentation. While not suitable for every patient requiring an aortic valve procedure, these less invasive operations can offer certain clinical benefits and are becoming an important part of the modern cardiothoracic surgeon’s skillset. A lower partial sternotomy approach provides excellent visualization of the operative field, efficient execution of the operation and many of the benefits of minimally invasive surgery. Importantly, the lower partial sternotomy requires no new or unusual instruments and presents a familiar view to the surgeon. The technique, therefore, lends itself well to being adapted and utilized quickly with a potentially shorter “learning curve” for maximal surgical flexibility and patient benefit. PMID:24251024

  16. Elevation of B-Type Natriuretic Peptide at Discharge is Associated With 2-Year Mortality After Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis: Insights From a Multicenter Prospective OCEAN-TAVI (Optimized Transcatheter Valvular Intervention-Transcatheter Aortic Valve Implantation) Registry.

    PubMed

    Mizutani, Kazuki; Hara, Masahiko; Iwata, Shinichi; Murakami, Takashi; Shibata, Toshihiko; Yoshiyama, Minoru; Naganuma, Toru; Yamanaka, Futoshi; Higashimori, Akihiro; Tada, Norio; Takagi, Kensuke; Araki, Motoharu; Ueno, Hiroshi; Tabata, Minoru; Shirai, Shinichi; Watanabe, Yusuke; Yamamoto, Masanori; Hayashida, Kentaro

    2017-07-14

    In this study, we sought to investigate the 2-year prognostic impact of B-type natriuretic peptide (BNP) levels at discharge, following transcatheter aortic valve replacement. We enrolled 1094 consecutive patients who underwent transcatheter aortic valve replacement between 2013 and 2016. Study patients were stratified into 2 groups according to survival classification and regression tree analysis (high versus low BNP groups). We evaluated the impact of high BNP on 2-year mortality compared with that of low BNP using a multivariable Cox model, and assessed whether this stratification would improve predictive accuracy for determining 2-year mortality by assessing time-dependent net reclassification improvement and integrated discrimination improvement. The median age of patients was 85 years (quartile 82-88), and 29.2% of the study population were men. The median Society of Thoracic Surgeons score was 6.8 (4.7-9.5), and BNP at discharge was 186 (93-378) pg/mL. All-cause mortality following discharge was 7.9% (95% CI, 5.8-9.9%) at 1 year and 15.4% (95% CI, 11.6-19.0%) at 2 years. The survival classification and regression tree analysis revealed that the discriminating BNP level to discern 2-year mortality was 202 pg/mL, and that elevated BNP had a statistically significant impact on outcomes, with an adjusted hazard ratio of 2.28 (1.36-3.82, P =0.002). The time-dependent net reclassification improvement ( P =0.047) and integrated discrimination improvement ( P =0.029) analysis revealed that the incorporation of BNP stratification with other clinical variables significantly improved predictive accuracy for 2-year mortality. Elevation of BNP at discharge is associated with 2-year mortality after transcatheter aortic valve replacement. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  17. Procedural Experience for Transcatheter Aortic Valve Replacement and Relation to Outcomes: The STS/ACC TVT Registry.

    PubMed

    Carroll, John D; Vemulapalli, Sreekanth; Dai, Dadi; Matsouaka, Roland; Blackstone, Eugene; Edwards, Fred; Masoudi, Frederick A; Mack, Michael; Peterson, Eric D; Holmes, David; Rumsfeld, John S; Tuzcu, E Murat; Grover, Frederick

    2017-07-04

    Transcatheter aortic valve replacement (TAVR) has been introduced into U.S. clinical practice with efforts to optimize outcomes and minimize the learning curve. The goal of this study was to assess the degree to which increasing experience during the introduction of this procedure, separated from other outcome determinants including patient and procedural characteristics, is associated with outcomes. The authors evaluated the association of hospital TAVR volume and patient outcomes for TAVR by using data from 42,988 commercial procedures conducted at 395 hospitals submitting to the Transcatheter Valve Therapy Registry from 2011 through 2015. Outcomes assessed included adjusted and unadjusted in-hospital major adverse events. Increasing site volume was associated with lower in-hospital risk-adjusted outcomes, including mortality (p < 0.02), vascular complications (p < 0.003), and bleeding (p < 0.001) but was not associated with stroke (p = 0.14). From the first case to the 400th case in the volume-outcome model, risk-adjusted adverse outcomes declined, including mortality (3.57% to 2.15%), bleeding (9.56% to 5.08%), vascular complications (6.11% to 4.20%), and stroke (2.03% to 1.66%). Vascular and bleeding volume-outcome associations were nonlinear with a higher risk of adverse outcomes in the first 100 cases. An association of procedure volume with risk-adjusted outcomes was also seen in the subgroup having transfemoral access. The initial adoption of TAVR into practice in the United States showed that increasing experience was associated with better outcomes. This association, whether deemed a prolonged learning curve or a manifestation of a volume-outcome relationship, suggested that concentrating experience in higher volume heart valve centers might be a means of improving outcomes. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All

  18. [Directions for reoperation of patients with Björk-Shiley convexo-concave valve prosthesis, based on long-term experience].

    PubMed

    Yamaki, F; Nakano, K; Endo, M; Hashimoto, A; Koyanagi, H

    1994-02-01

    Although a high incidence of strut fracture of the Björk-Shiley convexo-concave (C-C) valve prosthesis has been reported, it is still controversial whether the prosthesis functioning normally should be replaced electively. To clarify our policy for this issue, we reviewed 28 patients who had undergone mitral valve replacement with a C-C valve prosthesis, and evaluated long-term results according to STS guidelines. The incidence of valve-related complications expressed as % patient-year were; structural deterioration 0.30, nonstructural dysfunction 0.30, thromboembolism 1.20. There were no thrombosed valves, anticoagulant-related hemorrhage or prosthetic valve endocarditis. The actuarial free rate after valve replacement with the C-C at 10 years, constructed by the Kaplan-Meier method, were compared with those with St. Jude Medical (SJM) valve prosthesis. (1) Actuarial survival: 77.9 vs 87.3 (NS), (2) Reoperation-free: 91.6 vs 98.0 (p < 0.05), (3) thromboembolism-free: 83.7 vs 83.9 (NS), (4) Event-free (hospital death+reoperation+valve-related complications: 71.2 vs 77.7 (NS). The long-term results with the C-C were compatible to those with a SJM valve prosthesis. However, if a strut fracture occurs, it is very difficult to save the patient's life. The hospital mortality of re-replacement of valve prosthesis during the last 10 years, at our institute, was 2.6%, which is almost equal to the cumulative risk of strut fracture of the C-C valve after 10 years (3.0%).(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Relative Expression of PBMC MicroRNA-133a Analysis in Patients Receiving Warfarin After Mechanical Heart Valve Replacement

    PubMed Central

    Kabiri Rad, Hamid; Mazaheri, Mahta; Dehghani Firozabadi, Ali

    Background: MicroRNAs (miRNAs) are implicated in various biological processes including anticoagulation. However, the modulation of miRNA by pharmacological intervention such as warfarin treatment in patients receiving warfarin has not been disclosed yet. The aim of this study work was to assess the effect of warfarin drug on expression level of mir-133a-3p in patients with mechanical heart valve replacement. Methods: In this research, the expression level of miRNA-133a-3p was analyzed in Peripheral Blood Mononuclear Cells (PBMCs) from mechanical valve replacement patients who had received warfarin for at least 3 months continuously. Quantitative RT-PCR method was used for this assay. Results: Our findings indicated a significant diffrence between the rate of miR-133a-3p expression in individuals receiving warfarin and the control group (p<0.01). There was also a statistically significant difference in miR-133a-3p expression in patients with different ages (p<0.05) suggesting that the rate of miR-133a-3p expression in persons receiving warfarin is related to age. However, other variables like warfarin dose, International Normalized Ratio (INR), gender, and Body Mass Index (BMI) were not significantly effective on the miR-133a-3p experssion rate in individuals receving warfarin. Conclusion: Based on our results, it can be concluded that miR-133a-3p is involved in the coagulation pathway. The recent result indicates that warfarin affects the expression of miR-133a. This expression may be potentially important for treatment by anticoagulants. Awareness of the time course of miRNA expression profile can improve efficiency of response to warfarin. PMID:29296264

  20. Closed bore XMR (CBXMR) systems for aortic valve replacement: Investigation of rotating-anode x-ray tube heat loadability

    PubMed Central

    Bracken, John A.; Lillaney, Prasheel V.; Fahrig, Rebecca; Rowlands, J. A.

    2008-01-01

    In order to improve the safety and efficacy of percutaneous aortic valve replacement procedures, a closed bore hybrid x-ray∕MRI (CBXMR) system is proposed in which an x-ray C-arm will be positioned with its isocenter ≈1 m from the entrance of a clinical MRI scanner. This system will harness the complementary strengths of both modalities to improve clinical outcome. A key component of the CBXMR system will be a rotating anode x-ray tube to produce high-quality x-ray images. There are challenges in positioning an x-ray tube in the magnetic fringe field of the MRI magnet. Here, the effects of an external magnetic field on x-ray tube induction motors of radiography x-ray tubes and the corresponding reduction of x-ray tube heat loadability are investigated. Anode rotation frequency fanode was unaffected when the external magnetic field Bb was parallel to the axis of rotation of the anode but decreased when Bb was perpendicular to the axis of rotation. The experimental fanode values agreed with predicted values to within ±3% over a Bb range of 0–30 mT. The MRI fringe field at the proposed location of the x-ray tube mounted on the C-arm (≈4 mT) reduced fanode by only 1%, so x-ray tube heat loadability will not be compromised when using CBXMR systems for percutaneous aortic valve replacement procedures. Eddy current heating power in the rotor due to an MRI fringe field was found to be two orders of magnitude weaker than the heating power produced on the anode due to a fluoroscopic exposure, so eddy current heating had no effect on x-ray tube heat loadability. PMID:18841857