Sample records for valve surgery microwave

  1. The Leipzig experience with robotic valve surgery.

    PubMed

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  2. Evolving Indications for Tricuspid Valve Surgery

    PubMed Central

    Sales, Virna L.

    2010-01-01

    Opinion statement More attention has been paid to the mitral valve (MV) than the tricuspid valve (TV), and this relative paucity of data has led to confusion regarding the timing of TV surgery. We review the American College of Cardiology/American Heart Association and European Society of Cardiology guidelines to identify areas of concordance (severe tricuspid regurgitation [TR] in a patient undergoing mitral valve surgery); discordance (less than severe TR but with markers for late TR recurrence such as pulmonary hypertension, a dilated TV annulus, atrial fibrillation, permanent transtricuspid pacing wires and others); and disagreement (surgery for primary TR). We provide our perspective from Northwestern University on these issues and where the guidelines are silent (TR in patients undergoing non-mitral valve operations). Finally, we review recent publications on the results of TV repair and replacement. Although there have been scant publications in the past, there have been more useful publications in recent years to guide our decision making. PMID:21063935

  3. [Ahmed valve in glaucoma surgery].

    PubMed

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  4. Trends and outcomes of valve surgery: 16-year results of Netherlands Cardiac Surgery National Database.

    PubMed

    Siregar, Sabrina; de Heer, Frederiek; Groenwold, Rolf H H; Versteegh, Michel I M; Bekkers, Jos A; Brinkman, Emile S; Bots, Michiel L; van der Graaf, Yolanda; van Herwerden, Lex A

    2014-09-01

    The aim was to describe procedural volumes, patient risk profile and outcomes of heart valve surgery in the past 16 years in Netherlands. The Dutch National Database for Cardio-Thoracic Surgery includes approximately 200 000 cardiac operations performed between 1995 and 2010. Information on all valve surgeries (56 397 operations) was extracted. We determined trends for changes in procedural volume, demographics, risk profile and in-hospital mortality of valve operations. Because of incomplete data in the first years of registration, the total number of operations in those years was estimated using Poisson regression. For a subset from 2007 to 2010, follow-up data were available. Survival status was obtained through linkage with the national Cause of Death Registry, and survival analysis was performed using Kaplan-Meier method. Information on discharge and readmissions was obtained from the National Hospital Discharge Registry. The annual volume of heart valve operations increased by more than 100% from an estimated 2431 in 1995 to 5906 in 2010. Adjusted for population size in Netherlands, the number of operations per 100 000 adults increased from 20 in 1995 to 43 in 2010. In 2010, frequently performed valve surgery included the following: 34.6% isolated aortic valve (AoV) replacement, 21.8% AoV replacement and coronary artery bypass grafting (CABG), 14.6% isolated mitral valve surgery (repair or replacement) and 9.1% mitral valve and CABG. In AoV surgery, an increasing use of bioprostheses in all age categories is observed. In mitral valve surgery, 75.4% was performed by repair rather than replacement in 2010. In-hospital mortality for all valve surgery decreased significantly from 4.6% in 2007 to 3.6% in 2010, whereas the mean logistic EuroSCORE remained stable (median 5.8, P = 1.000). Thirty-day mortality after all valve surgery was 3.9% and 120-day mortality was 6.5%. At 1 year, survival after all valve surgery was 91.6% and a reoperation had been performed in 1

  5. Triple valve surgery: a 25-year experience.

    PubMed

    Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen

    2004-09-01

    Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become

  6. Prior oral conditions in patients undergoing heart valve surgery.

    PubMed

    Silvestre, Francisco-Javier; Gil-Raga, Irene; Martinez-Herrera, Mayte; Lauritano, Dorina; Silvestre-Rangil, Javier

    2017-11-01

    Patients scheduled for heart valve surgery should be free of any oral infectious disorders that might pose a risk in the postoperative period. Few studies have been made on the dental conditions of such patients prior to surgery. The present study describes the most frequent prior oral diseases in this population group. A prospective, observational case-control study was designed involving 60 patients (30 with heart valve disease and 30 controls, with a mean age of 71 years in both groups). A dental exploration was carried out, with calculation of the DMFT (decayed, missing and filled teeth) index and recording of the periodontal parameters (plaque index, gingival bleeding index, periodontal pocket depth, and attachment loss). The oral mucosa was also examined, and panoramic X-rays were used to identify possible intrabony lesions. Significant differences in bacterial plaque index were observed between the two groups ( p <0.05), with higher scores in the patients with valve disease. Probing depth and the presence of moderate pockets were also greater in the patients with valve disease than among the controls ( p <0.01). Sixty percent of the patients with valve disease presented periodontitis. Patients scheduled for heart valve surgery should be examined for possible active periodontitis before the operation. Those individuals found to have periodontal disease should receive adequate periodontal treatment before heart surgery. Key words: Valve disease, aortic, mitral, heart surgery, periodontitis.

  7. Prior oral conditions in patients undergoing heart valve surgery

    PubMed Central

    Gil-Raga, Irene; Martinez-Herrera, Mayte; Lauritano, Dorina; Silvestre-Rangil, Javier

    2017-01-01

    Background Patients scheduled for heart valve surgery should be free of any oral infectious disorders that might pose a risk in the postoperative period. Few studies have been made on the dental conditions of such patients prior to surgery. The present study describes the most frequent prior oral diseases in this population group. Material and Methods A prospective, observational case-control study was designed involving 60 patients (30 with heart valve disease and 30 controls, with a mean age of 71 years in both groups). A dental exploration was carried out, with calculation of the DMFT (decayed, missing and filled teeth) index and recording of the periodontal parameters (plaque index, gingival bleeding index, periodontal pocket depth, and attachment loss). The oral mucosa was also examined, and panoramic X-rays were used to identify possible intrabony lesions. Results Significant differences in bacterial plaque index were observed between the two groups (p<0.05), with higher scores in the patients with valve disease. Probing depth and the presence of moderate pockets were also greater in the patients with valve disease than among the controls (p<0.01). Sixty percent of the patients with valve disease presented periodontitis. Conclusions Patients scheduled for heart valve surgery should be examined for possible active periodontitis before the operation. Those individuals found to have periodontal disease should receive adequate periodontal treatment before heart surgery. Key words:Valve disease, aortic, mitral, heart surgery, periodontitis. PMID:29302279

  8. Engine Cycle Analysis of Air Breathing Microwave Rocket with Reed Valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fukunari, Masafumi; Komatsu, Reiji; Yamaguchi, Toshikazu

    The Microwave Rocket is a candidate for a low cost launcher system. Pulsed plasma generated by a high power millimeter wave beam drives a blast wave, and a vehicle acquires impulsive thrust by exhausting the blast wave. The thrust generation process of the Microwave Rocket is similar to a pulse detonation engine. In order to enhance the performance of its air refreshment, the air-breathing mechanism using reed valves is under development. Ambient air is taken to the thruster through reed valves. Reed valves are closed while the inside pressure is high enough. After the time when the shock wave exhaustsmore » at the open end, an expansion wave is driven and propagates to the thrust-wall. The reed valve is opened by the negative gauge pressure induced by the expansion wave and its reflection wave. In these processes, the pressure oscillation is important parameter. In this paper, the pressure oscillation in the thruster was calculated by CFD combined with the flux through from reed valves, which is estimated analytically. As a result, the air-breathing performance is evaluated using Partial Filling Rate (PFR), the ratio of thruster length to diameter L/D, and ratio of opening area of reed valves to superficial area {alpha}. An engine cycle and predicted thrust was explained.« less

  9. Mitral regurgitation after previous aortic valve surgery for bicuspid aortic valve insufficiency.

    PubMed

    Girdauskas, Evaldas; Disha, Kushtrim; Espinoza, Andres; Misfeld, Martin; Reichenspurner, Hermann; Borger, Michael A; Kuntze, Thomas

    2017-06-01

    Regurgitant bicuspid aortic valves (BAV) are reported to be associated with myxomatous degeneration of the anterior mitral leaflet. We examined the risk of late new-onset mitral regurgitation (MR) in patients who underwent aortic valve/aortic root surgery for BAV regurgitation and concomitant root dilatation. A total of 97 consecutive patients (47±11 years, 94% men) were identified from our institutional BAV database (N.=640) based on the following criteria: 1) BAV regurgitation; 2) aortic root diameter >40 mm; 3) no relevant mitral valve disease (i.e., MR<2+) and no simultaneous mitral intervention at the time of BAV surgery. All patients underwent isolated aortic valve replacement (AVR subgroup, N.=59) or aortic root replacement with a composite graft (i.e., for root aneurysm >50 mm) (ARR subgroup, N.=38) from 1995 through 2008. Echocardiographic follow-up (1009 patient-years) was obtained for all 96 (100%) hospital survivors. The primary endpoint was freedom from new-onset MR>2+ and redo mitral valve surgery. Nine patients (9.4%) showed new-onset MR>2+ after mean echocardiographic follow-up of 10.4±4.0 years postoperatively. Myxomatous degeneration and prolapse of the anterior mitral leaflet was found in all 9 patients, and the posterior leaflet was involved in 3 of them. Two patients (2%) in AVR subgroup underwent re-do mitral surgery. No MR>2+ occurred in ARR subgroup. Freedom from MR>2+ or mitral surgery at 15 years was significantly lower in AVR subgroup vs. ARR subgroup (i.e., 38% vs. 100%, P=0.01). The risk of new-onset MR is significantly increased in patients with BAV regurgitation and aortic root dilatation who undergo isolated AVR rather than root replacement. The mechanism by which aortic root replacement may prevent the occurrence of late MR in BAV root phenotype patients is to be determined.

  10. Incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery.

    PubMed

    LaPietra, Angelo; Santana, Orlando; Mihos, Christos G; DeBeer, Steven; Rosen, Gerald P; Lamas, Gervasio A; Lamelas, Joseph

    2014-07-01

    Minimally invasive valve surgery has been associated with increased cerebrovascular complications. Our objective was to evaluate the incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery. We retrospectively reviewed all the minimally invasive valve surgery performed at our institution from January 2009 to June 2012. The operative times, lengths of stay, postoperative complications, and mortality were analyzed. A total of 1501 consecutive patients were identified. The mean age was 73 ± 13 years, and 808 patients (54%) were male. Of the 1501 patients, 206 (13.7%) had a history of a cerebrovascular accident, and 225 (15%) had undergone previous heart surgery. The procedures performed were 617 isolated aortic valve replacements (41.1%), 658 isolated mitral valve operations (43.8%), 6 tricuspid valve repairs (0.4%), 216 double valve surgery (14.4%), and 4 triple valve surgery (0.3%). Femoral cannulation was used in 1359 patients (90.5%) and central cannulation in 142 (9.5%). In 1392 patients (92.7%), the aorta was clamped, and in 109 (7.3%), the surgery was performed with the heart fibrillating. The median aortic crossclamp and cardiopulmonary bypass times were 86 minutes (interquartile range [IQR], 70-107) minutes and 116 minutes (IQR, 96-143), respectively. The median intensive care unit length of stay was 47 hours (IQR, 29-74), and the median postoperative hospital length of stay was 7 days (IQR, 5-10). A total of 23 cerebrovascular accidents (1.53%) and 38 deaths (2.53%) had occurred at 30 days postoperatively. Minimally invasive valve surgery was associated with an acceptable stroke rate, regardless of the cannulation technique. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  11. Recent progress in heart valve surgery: innovation or evolution?

    PubMed

    Lausberg, H; Schäfers, H J

    2004-08-01

    Although heart valve surgery continues to evolve in a dynamic fashion, there is still no optimal solution for all patients. Minimally invasive surgery currently receives considerable attention but its value still needs to be determined. Progress has been made in valve repair, which now allows reconstruction in most patients with mitral valve disease. Reconstruction of the aortic valve is now also possible with results that are now comparable to those of mitral repair. In the future a wider application of repair procedures and further improvements of biologic valves can be anticipated not only to influence long-term results, but also the decision making process for conservative or surgical treatment.

  12. Reasons for conversion and adverse intraoperative events in Endoscopic Port Access™ atrioventricular valve surgery and minimally invasive aortic valve surgery.

    PubMed

    van der Merwe, Johan; Van Praet, Frank; Stockman, Bernard; Degrieck, Ivan; Vermeulen, Yvette; Casselman, Filip

    2018-02-14

    This study reports the factors that contribute to sternotomy conversions (SCs) and adverse intraoperative events in minimally invasive aortic valve surgery (MI-AVS) and minimally invasive Endoscopic Port Access™ atrioventricular valve surgery (MI-PAS). In total, 3780 consecutive patients with either aortic valve disease or atrioventricular valve disease underwent minimally invasive valve surgery (MIVS) at our institution between 1 February 1997 and 31 March 2016. MI-AVS was performed in 908 patients (mean age 69.2 ± 11.3 years, 45.2% women, 6.2% redo cardiac surgery) and MI-PAS in 2872 patients (mean age 64.1 ± 13.3 years, 46.7% women, 12.2% redo cardiac surgery). A cumulative total of 4415 MIVS procedures (MI-AVS = 908, MI-PAS = 3507) included 1537 valve replacements (MI-AVS = 896, MI-PAS = 641) and 2878 isolated or combined valve repairs (MI-AVS = 12, MI-PAS = 2866). SC was required in 3.0% (n = 114 of 3780) of MIVS patients, which occurred in 3.1% (n = 28 of 908) of MI-AVS patients and 3.0% (n = 86 of 2872) of MI-PAS patients, respectively. Reasons for SC in MI-AVS included inadequate visualization (n = 4, 0.4%) and arterial cannulation difficulty (n = 7, 0.8%). For MI-PAS, SC was required in 54 (2.5%) isolated mitral valve procedures (n = 2183). Factors that contributed to SC in MI-PAS included lung adhesions (n = 35, 1.2%), inadequate visualization (n = 2, 0.1%), ventricular bleeding (n = 3, 0.1%) and atrioventricular dehiscence (n = 5, 0.2%). Neurological deficit occurred in 1 (0.1%) and 3 (3.5%) MI-AVS and MI-PAS conversions, respectively. No operative or 30-day mortalities were observed in MI-AVS conversions (n = 28). The 30-day mortality associated with SC in MI-PAS (n = 86) was 10.5% (n = 9). MIVS is increasingly being recognized as the 'gold-standard' for surgical valve interventions in the context of rapidly expanding catheter-based technology and increasing

  13. [Ministernotomy: a preliminary experience in heart valve surgery].

    PubMed

    Kovarević, Pavle; Mihajlović, Bogoljub; Velicki, Lazar; Redzek, Aleksandar; Ivanović, Vladimir; Komazec, Nikola

    2011-05-01

    The last decade of the 20th century brought up a significant development in the field of minimally invasive approaches to the valvular heart surgery. Potential benefits of this method are: good esthetic appearance, reduced pain, reduction of postoperative hemorrhage and incidence of surgical site infection, shorter postoperative intensive care units (ICU) period and overall in-hospital period. Partial upper median stemotomy currently presents as a state-of-the art method for minimally invasive surgery of cardiac valves. The aim of this study was to report on initial experience in application of this surgical method in the surgery of mitral and aortic valves. The study was designed and conducted in a prospective manner and included all the patients who underwent minimally invasive cardiac valve surgery through the partial upper median stemotomy during the period November 2008 - August 2009. We analyzed the data on mean age of patients, mean extubation time, mean postoperative drainage, mean duration of hospital stay, as well as on occurance of postoperative complications (postoperative bleeding, surgical site infection and cerebrovascular insult). During the observed period, in the Institute for Cardiovascular Diseases of Vojvodina, Clinic for Cardiovascular Surgery, 17 ministernotomies were performed, with 14 aortic valve replacements (82.35%) and 3 mitral valve replacements (17.65%). Mean age of the patients was 60.78 +/- 12.99 years (64.71% males, 35.29% females). Mean extubation time was 12.53 +/- 8.87 hours with 23.5% of the patients extubated in less than 8 hours. Mean duration of hospital stay was 12.35 +/- 10.17 days (in 29.4% of the patients less than 8 days). Mean postoperative drainage was 547.06 +/- 335.2 mL. Postoperative complications included: bleeding (5.88%) and cerebrovascular insult (5.88%). One patient (5.88%) required conversion to full stemotomy. Partial upper median sternotomy represents the optimal surgical method for the interventions on the

  14. A new cannulation method for isolated mitral valve surgery--"apicoaortic-pa" cannulation.

    PubMed

    Wada, J; Komatsu, S; Nakae, S; Kazui, T

    1976-06-01

    The present paper describes experimental and clinical studies of a new method "Apicoaortic-PA" cannulation for mitral valve surgery. Our experimental study showed that this method was more rapid and more physiological for cardiopulmonary bypass. We used this technique in 55 cases of isolated mitral valve surgery with successful results. Our general philosophy of surgical approach to the mitral valve diseases is also discussed. We advocate the utilization of the "Apicoaortic Pulmonary Artery" cannulation method for clinical use in isolated mitral valve surgery through the left thoracotomy.

  15. Mitral Valve Surgery in Patients with Systemic Lupus Erythematosus

    PubMed Central

    Hekmat, Manouchehr; Ghorbani, Mohsen; Ghaderi, Hamid; Majidi, Masoud; Beheshti, Mahmood

    2014-01-01

    Valvular heart disease is the common cardiac manifestation of systemic lupus erythematosus (SLE) with a tendency for mitral valve regurgitation. In this study we report a case of mitral valve replacement for mitral stenosis caused by Libman-Sacks endocarditis in the setting of SLE. In addition, we provide a systematic review of the literature on mitral valve surgery in the presence of Libman-Sacks endocarditis because its challenge on surgical options continues. Surgical decision depends on structural involvement of mitral valve and presence of active lupus nephritis and antiphospholipid antibody syndrome. Review of the literature has also shown that outcome is good in most SLE patients who have undergone valvular surgery, but association of antiphospholipid antibody syndrome with SLE has negative impact on the outcome. PMID:25401131

  16. Cost effectiveness of robotic mitral valve surgery.

    PubMed

    Moss, Emmanuel; Halkos, Michael E

    2017-01-01

    Significant technological advances have led to an impressive evolution in mitral valve surgery over the last two decades, allowing surgeons to safely perform less invasive operations through the right chest. Most new technology comes with an increased upfront cost that must be measured against postoperative savings and other advantages such as decreased perioperative complications, faster recovery, and earlier return to preoperative level of functioning. The Da Vinci robot is an example of such a technology, combining the significant benefits of minimally invasive surgery with a "gold standard" valve repair. Although some have reported that robotic surgery is associated with increased overall costs, there is literature suggesting that efficient perioperative care and shorter lengths of stay can offset the increased capital and intraoperative expenses. While data on current cost is important to consider, one must also take into account future potential value resulting from technological advancement when evaluating cost-effectiveness. Future refinements that will facilitate more effective surgery, coupled with declining cost of technology will further increase the value of robotic surgery compared to traditional approaches.

  17. Combined PCI and minimally invasive heart valve surgery for high-risk patients.

    PubMed

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Zhao, David X; Byrne, John G

    2009-12-01

    Combined coronary artery valvular heart disease is a major cause of morbidity and mortality in the adult patient population. The standard treatment for such disease has been open heart surgery in which coronary artery bypass grafting (CABG) is performed concurrently with valve surgery using a median sternotomy and cardiopulmonary bypass. With the increasing complexity of patients referred to surgery, some patients may prove to be poor surgical candidates for combined valve and CABG surgery. In certain selected patients who fall into this category, valve surgery and percutaneous coronary intervention (PCI) have been considered a feasible alternative. Conventionally, valve surgery is performed in the cardiac surgical operating room, whereas PCI is carried out in the cardiac catheterization laboratory. Separation of these two procedural suites has presented a logistic limitation because it impedes the concomitant performance of both procedures in one setting. Hence, PCI and valve surgery usually have been performed as a "two-stage" procedure in two different operative suites, with the procedures being separated by hours, days, or weeks. Technologic advancements have made possible the construction of a "hybrid" procedural suite that combines the facilities of a cardiac surgical operating room with those of a cardiac catheterization laboratory. This design has enabled the concept of "one-stage" or "one-stop" PCI and valve surgery, allowing both procedures to be performed in a hybrid suite in one setting, separated by minutes. The advantages of such a method could prove to be multifold by enabling a less invasive surgical approach and improving logistics, patient satisfaction, and outcomes in selected patients.

  18. Physical and mental recovery after conventional aortic valve surgery.

    PubMed

    Petersen, Johannes; Vettorazzi, Eik; Winter, Lena; Schmied, Wolfram; Kindermann, Ingrid; Schäfers, Hans-Joachim

    2016-12-01

    Physical and mental recovery are important factors to consider in the treatment of aortic valve disease, and the process of recovery is not well known. We investigated the course of physical and mental recovery directly after conventional aortic valve surgery. In a longitudinal study, 60 patients undergoing elective aortic valve surgery were studied preoperatively and at intervals of 4 weeks after aortic valve surgery. The last measurement was taken 6 months postoperatively. Measurements included the 6-minute walk test and N-terminal pro-B-type natriuretic peptide. Mental recovery was assessed by the Short Form Health Survey and the Hospital Anxiety and Depression Scale. All parameters were compared with published healthy norms. All parameters except for the anxiety score showed a significant decline after the first postoperative measurement at 1 week after aortic valve surgery. The baseline level was restored at 1 to 3 weeks (anxiety, depression, mental quality of life, Borg scale), 4 to 6 weeks (6-minute walk test, physical quality of life), and 9 weeks (N-terminal pro-B-type natriuretic peptide) after the first postoperative week. Significantly better values than preoperatively for the first time were reached at 2 to 3 weeks (anxiety, depression, mental quality of life), 5 weeks (6-minute walk test), 8 weeks (physical quality of life), and 12 weeks (N-terminal pro-B-type natriuretic peptide) after the first postoperative week. At 3 months postoperatively, significant improvements (P < .001) were seen in walk distance (+212 m), dyspnea (-1.11), physical (+12.38) and mental quality of life (+7.71), anxiety (-3.74), and depression (-3.62) compared with the first week postoperatively. At 6 months postoperatively, all parameters were significantly improved compared with preoperative data and, except for the N-terminal pro-B-type natriuretic peptide value, significantly better or equal compared with published healthy norms. After conventional aortic

  19. Cost-effectiveness of homograft heart valve replacement surgery: an introductory study.

    PubMed

    Yaghoubi, Mohsen; Aghayan, Hamid Reza; Arjmand, Babak; Emami-Razavi, Seyed Hassan

    2011-05-01

    The clinical effectiveness of heart valve replacement surgery has been well documented. Mechanical and homograft valves are used routinely for replacement of damaged heart valves. Homograft valves are produced in our country but we import the mechanical valves. To our knowledge the cost-effectiveness of homograft valve has not been assessed. The objective of the present study was to compare the cost-effectiveness of homograft valve replacement with mechanical valve replacement surgery. Our samples were selected from 200 patients that underwent homograft and mechanical heart valve replacement surgery in Imam-Khomeini hospital (2000-2005). In each group we enrolled 30 patients. Quality of life was measured using the SF-36 questionnaire and utility was measured in quality-adjusted life years (QALYs). For each group we calculated the price of heart valve and hospitalization charges. Finally the cost-effectiveness of each treatment modalities were summarized as costs per QALYs gained. Forty male and twenty female participated in the study. The mean score of quality of life was 66.06 (SD = 9.22) in homograft group and 57.85 (SD = 11.30) in mechanical group (P < 0.05). The mean QALYs gained in homograft group was 0.67 more than mechanical group. The incremental cost-effectiveness ratio (ICER) revealed a cost savings of 1,067 US$ for each QALY gained in homograft group. Despite limitation of this introductory study, we concluded that homograft valve replacement was more effective and less expensive than mechanical valve. These findings can encourage healthcare managers and policy makers to support the production of homograft valves and allocate more recourse for developing such activities.

  20. Predictors of temporary epicardial pacing wires use after valve surgery

    PubMed Central

    2014-01-01

    Background Although temporary cardiac pacing is infrequently needed, temporary epicardial pacing wires are routinely inserted after valve surgery. As they are associated with infrequent, but life threatening complications, and the decreased need for postoperative pacing in a group of low risk patients; this study aims to identify the predictors of temporary cardiac pacing after valve surgery. Methods A retrospective analysis of data collected prospectively on 400 consecutive valve surgery patients between May 2002 and December 2012 was performed. Patients were grouped according to avoidance or insertion of temporary pacing wires, and were further subdivided according to temporary cardiac pacing need. Multiple logistic regression was used to determine the predictors of temporary cardiac pacing. Results 170 (42.5%) patients did not have insertion of temporary pacing wires and none of them needed temporary pacing. 230 (57.5%) patients had insertion of temporary pacing wires and among these, only 55 (23.9%) required temporary pacing who were compared with the remaining 175 (76.1%) patients in the main analysis. The determinants of temporary cardiac pacing (adjusted odds ratios; 95% confidence interval) were as follows: increased age (1.1; 1.1, 1.3, p = 0.002), New York Heart Association class III- IV (5.6; 1.6, 20.2, p = 0.008) , pulmonary artery pressure ≥ 50 mmHg (22.0; 3.4, 142.7, p = 0.01), digoxin use (8.0; 1.3, 48.8, p = 0.024), multiple valve surgery (13.5; 1.5, 124.0, p = 0.021), aorta cross clamp time ≥ 60 minutes (7.8; 1.6, 37.2, p = 0.010), and valve annulus calcification (7.9; 2.0, 31.7, p = 0.003). Conclusion Although limited by sample size, the present results suggest that routine use of temporary epicardial pacing wires after valve surgery is only necessary for high risk patients. Preoperative identification and aggressive management of predictors of temporary cardiac pacing and the possible modulation of

  1. Should high risk patients with concomitant severe aortic stenosis and mitral valve disease undergo double valve surgery in the TAVR era?

    PubMed

    Yu, Pey-Jen; Mattia, Allan; Cassiere, Hugh A; Esposito, Rick; Manetta, Frank; Kohn, Nina; Hartman, Alan R

    2017-12-29

    Significant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The aim of this study is to determine if surgical correction of both aortic and mitral valves in high risk patients with concomitant valvular disease would offer patients better outcomes than TAVR alone. A retrospective analysis of 43 high-risk patients who underwent concomitant surgical aortic valve replacement and mitral valve surgery from 2008 to 2012 was performed. Immediate and long term survival were assessed. There were 43 high-risk patients with severe aortic stenosis undergoing concomitant surgical aortic valve replacement and mitral valve surgery. The average age was 80 ± 6 years old. Nineteen (44%) patients had prior cardiac surgery, 15 (34.9%) patients had chronic obstructive lung disease, and 39 (91%) patients were in congestive heart failure. The mean Society of Thoracic Surgeons Predicted Risk of Mortality for isolated surgical aortic valve replacement for the cohort was 10.1% ± 6.4%. Five patients (11.6%) died during the index admission and/or within thirty days of surgery. Mortality rate was 25% at six months, 35% at 1 year and 45% at 2 years. There was no correlation between individual preoperative risk factors and mortality. High-risk patients with severe aortic stenosis and mitral valve disease undergoing concomitant surgical aortic valve replacement and mitral valve surgery may have similar long term survival as that described for such patients undergoing TAVR. Surgical correction of double valvular disease in this patient population may not confer mortality benefit compared to TAVR alone.

  2. Value of Robotically Assisted Surgery for Mitral Valve Disease

    PubMed Central

    Mihaljevic, Tomislav; Koprivanac, Marijan; Kelava, Marta; Goodman, Avi; Jarrett, Craig; Williams, Sarah J.; Gillinov, A. Marc; Bajwa, Gurjyot; Mick, Stephanie L.; Bonatti, Johannes; Blackstone, Eugene H.

    2014-01-01

    Importance The value of robotically assisted surgery for mitral valve disease is questioned because the high cost of care associated with robotic technology may outweigh its clinical benefits. Objective To investigate conditions under which benefits of robotic surgery mitigate high technology costs. Design Clinical cohort study comparing costs of robotic vs. three contemporaneous conventional surgical approaches for degenerative mitral disease. Surgery was performed from 2006–2011, and comparisons were based on intent-to-treat, with propensity-matching used to reduce selection bias. Setting Large multi-specialty academic medical center. Participants 1,290 patients aged 57±11 years, 27% women, underwent mitral repair for regurgitation from posterior leaflet prolapse. Robotic surgery was used in 473, complete sternotomy in 227, partial sternotomy in 349, and anterolateral thoracotomy in 241. Three propensity-matched groups were formed based on demographics, symptoms, cardiac and noncardiac comorbidities, valve pathophysiology, and echocardiographic measurements: robotic vs. sternotomy (n=198 pairs) vs. partial sternotomy (n=293 pairs) vs. thoracotomy (n=224 pairs). Interventions Mitral valve repair. Main Outcome Measures Cost of care, expressed as robotic capital investment, maintenance, and direct technical hospital cost, and benefit of care, based on differences in recovery time. Results Median cost of care for robotically assisted surgery exceeded the cost of alternative approaches by 27% (−5%, 68%), 32% (−6%, 70%), and 21% (−2%, 54%) (median [15th, 85th percentiles]) for complete sternotomy, partial sternotomy, and anterolateral thoracotomy, respectively. Higher operative costs were partially offset by lower postoperative costs and earlier return to work: median 35 days for robotic surgery, 49 for complete sternotomy, 56 for partial sternotomy, and 42 for anterolateral thoracotomy. Resulting net differences in cost of robotic surgery vs. the three

  3. Redo aortic valve surgery versus transcatheter valve-in-valve implantation for failing surgical bioprosthetic valves: consecutive patients in a single-center setting

    PubMed Central

    Wottke, Michael; Deutsch, Marcus-André; Krane, Markus; Piazza, Nicolo; Lange, Ruediger; Bleiziffer, Sabine

    2015-01-01

    Background Due to a considerable rise in bioprosthetic as opposed to mechanical valve implantations, an increase of patients presenting with failing bioprosthetic surgical valves in need of a reoperation is to be expected. Redo surgery may pose a high-risk procedure. Transcatheter aortic valve-in-valve implantation is an innovative, less-invasive treatment alternative for these patients. However, a comprehensive evaluation of the outcome of consecutive patients after a valve-in-valve TAVI [transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV)] as compared to a standard reoperation [surgical aortic valve redo-operation (SAV-in-SAV)] has not yet been performed. The goal of this study was to compare postoperative outcomes after TAV-in-SAV and SAV-in-SAV in a single center setting. Methods All SAV-in-SAV and TAV-in-SAV patients from January 2001 to October 2014 were retrospectively reviewed. Patients with previous mechanical or transcatheter valves, active endocarditis and concomitant cardiac procedures were excluded. Patient characteristics, preoperative data, post-procedural complications, and 30-day mortality were collected from a designated database. Mean values ± SD were calculated for all continuous variables. Counts and percentages were calculated for categorical variables. The Chi-square and Fisher exact tests were used to compare categorical variables. Continuous variables were compared using the t-test for independent samples. A 2-sided P value <0.05 was considered statistically significant. Results A total of 102 patients fulfilled the inclusion criteria, 50 patients (49%) underwent a transcatheter valve-in-valve procedure, while 52 patients (51%) underwent redo-surgery. Patients in the TAV-in-SAV group were significantly older, had a higher mean logistic EuroSCORE and exhibited a lower mean left ventricular ejection fraction than patients in the SAV-in-SAV group (78.1±6.7 vs. 66.2±13.1, P<0.001; 27.4±18.7 vs. 14.4±10, P<0.001; and 49.8±13

  4. Tricuspid regurgitation after successful mitral valve surgery

    PubMed Central

    Katsi, Vasiliki; Raftopoulos, Leonidas; Aggeli, Constantina; Vlasseros, Ioannis; Felekos, Ioannis; Tousoulis, Dimitrios; Stefanadis, Christodoulos; Kallikazaros, Ioannis

    2012-01-01

    The tricuspid valve (TV) is inseparably connected with the mitral valve (MV) in terms of function. Any pathophysiological condition concerning the MV is potentially a threat for the normal function of the TV as well. One of the most challenging cases is functional tricuspid regurgitation (TR) after surgical MV correction. In the past, TR was considered to progressively revert with time after left-sided valve restoration. Nevertheless, more recent studies showed that TR could develop and evolve postoperatively over time, as well as being closely associated with a poorer prognosis in terms of morbidity and mortality. Pressure and volume overload are usually the underlying pathophysiological mechanisms; structural alterations, like tricuspid annulus dilatation, increased leaflet tethering and right ventricular remodelling are almost always present when regurgitation develops. The most important risk factors associated with a higher probability of late TR development involve the elderly, female gender, larger left atrial size, atrial fibrillation, right chamber dilatation, higher pulmonary artery systolic pressures, longer times from the onset of MV disease to surgery, history of rheumatic heart disease, ischaemic heart disease and prosthetic valve malfunction. The time of TR manifestation can be up to 10 years or more after an MV surgery. Echocardiography, including the novel 3D Echo techniques, is crucial in the early diagnosis and prognosis of future TV disease development. Appropriate surgical technique and timing still need to be clarified. PMID:22457188

  5. Atrial fibrillation surgery in nonrheumatic mitral valve disease.

    PubMed

    Gillinov, Marc

    2007-12-01

    Atrial fibrillation (AF) is present in 30-50% of patients presenting for mitral valve surgery. If left untreated, AF in these patients is associated with increased morbidity and, possibly, increased mortality. Therefore, concomitant management of the arrhythmia is indicated in most mitral valve patients with preexisting AF. The cut-and-sew Cox-Maze III procedure is extremely effective, eliminating AF in 80-95%; however, it has been supplanted by newer operations that rely upon alternate energy sources to create lines of conduction block. Early and midterm results are good with a variety of technologies. Choice of lesion set remains a matter of debate, but success of ablation appears to be enhanced by a biatrial lesion set and exceeds 90% in some series. Targeted areas for improvement in combined mitral valve surgery and AF ablation include acceptance of uniform standards for reporting results, development of improved technology for ablation and intraoperative assessment, and creation of instrumentation that facilitates minimally invasive approaches.

  6. Trans-catheter aortic valve implantation after previous aortic homograft surgery.

    PubMed

    Drews, Thorsten; Pasic, Miralem; Buz, Semih; Unbehaun, Axel

    2011-12-01

    In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  7. Minimally invasive redo mitral valve surgery without aortic crossclamp.

    PubMed

    Milani, Rodrigo; Brofman, Paulo Roberto Slud; Oliveira, Sergio; Patrial Neto, Luiz; Rosa, Matheus; Lima, Victor Hugo; Binder, Luis Fernando; Sanches, Aline

    2013-01-01

    Reoperations of the mitral valve have a higher rate of complications when compared with the first surgery. With the field of video-assisted techniques for the first surgery of mitral valve became routine, reoperation cases began to arouse interest for this less invasive procedures. To assess the results and the technical difficulties in 10 patients undergoing minimally invasive redo mitral valve surgery. Cardiopulmonary bypass was installed through a cannula placed in the femoral vessels and right internal jugular vein, conducted in 28 degrees of temperature in ventricular fibrillation. A right lateral thoracotomy with 5 to 6 cm in the third or fourth intercostal space was done, pericardium was displaced only at the point of atriotomy. The aorta was not clamped. Ten patients with mean age of 56.9 ± 10.5 years, four were in atrial fibrilation rhythm and six in sinusal. Average time between first operation and reoperations was 11 ± 3.43 years. The mean EuroSCORE group was 8.3 ± 1.82. The mean ventricular fibrillation and cardiopulmonary bypass was respectively 70.9 ± 17.66 min and 109.4 ± 25.37 min. The average length of stay was 7.6 ± 1.5 days. There were no deaths in this series. Mitral valve reoperation can be performed through less invasive techniques with good immediate results, low morbidity and mortality. However, this type of surgery requires a longer duration of cardiopulmonary bypass, especially in cases where the patient already has prosthesis. The presence of a minimal aortic insufficiency also makes this procedure technically more challenging.

  8. Surgical treatment of tricuspid regurgitation after mitral valve surgery: a retrospective study in China

    PubMed Central

    2012-01-01

    Background Functional tricuspid regurgitation (TR) occurs in patients with rheumatic mitral valve disease even after mitral valve surgery. The aim of this study was to analyze surgical results of TR after previous successful mitral valve surgery. Methods From September 1996 to September 2008, 45 patients with TR after previous mitral valve replacement underwent second operation for TR. In those, 43 patients (95.6%) had right heart failure symptoms (edema of lower extremities, ascites, hepatic congestion, etc.) and 40 patients (88.9%) had atrial fibrillation. Twenty-six patients (57.8%) were in New York Heart Association (NYHA) functional class III, and 19 (42.2%) in class IV. Previous operations included: 41 for mechanical mitral valve replacement (91.1%), 4 for bioprosthetic mitral valve replacement (8.9%), and 7 for tricuspid annuloplasty (15.6%). Results The tricuspid valves were repaired with Kay's (7 cases, 15.6%) or De Vega technique (4 cases, 8.9%). Tricuspid valve replacement was performed in 34 cases (75.6%). One patient (2.2%) died. Postoperative low cardiac output (LCO) occurred in 5 patients and treated successfully. Postoperative echocardiography showed obvious reduction of right atrium and ventricle. The anterioposterior diameter of the right ventricle decreased to 25.5 ± 7.1 mm from 33.7 ± 6.2 mm preoperatively (P < 0. 05). Conclusion TR after mitral valve replacement in rheumatic heart disease is a serious clinical problem. If it occurs or progresses late after mitral valve surgery, tricuspid valve annuloplasty or replacement may be performed with satisfactory results. Due to the serious consequence of untreated TR, aggressive treatment of existing TR during mitral valve surgery is recommended. PMID:22490269

  9. Surgery for rheumatic mitral valve disease in sub-saharan African countries: why valve repair is still the best surgical option.

    PubMed

    Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie

    2016-01-01

    Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.

  10. Exercise-based cardiac rehabilitation for adults after heart valve surgery.

    PubMed

    Sibilitz, Kirstine L; Berg, Selina K; Tang, Lars H; Risom, Signe S; Gluud, Christian; Lindschou, Jane; Kober, Lars; Hassager, Christian; Taylor, Rod S; Zwisler, Ann-Dorthe

    2016-03-21

    Exercise-based cardiac rehabilitation may benefit heart valve surgery patients. We conducted a systematic review to assess the evidence for the use of exercise-based intervention programmes following heart valve surgery. To assess the benefits and harms of exercise-based cardiac rehabilitation compared with no exercise training intervention, or treatment as usual, in adults following heart valve surgery. We considered programmes including exercise training with or without another intervention (such as a psycho-educational component). We searched: the Cochrane Central Register of Controlled Trials (CENTRAL); the Database of Abstracts of Reviews of Effects (DARE); MEDLINE (Ovid); EMBASE (Ovid); CINAHL (EBSCO); PsycINFO (Ovid); LILACS (Bireme); and Conference Proceedings Citation Index-S (CPCI-S) on Web of Science (Thomson Reuters) on 23 March 2015. We handsearched Web of Science, bibliographies of systematic reviews and trial registers (ClinicalTrials.gov, Controlled-trials.com, and The World Health Organization International Clinical Trials Registry Platform). We included randomised clinical trials that investigated exercise-based interventions compared with no exercise intervention control. The trial participants comprised adults aged 18 years or older who had undergone heart valve surgery for heart valve disease (from any cause) and received either heart valve replacement, or heart valve repair. Two authors independently extracted data. We assessed the risk of systematic errors ('bias') by evaluation of bias risk domains. Clinical and statistical heterogeneity were assessed. Meta-analyses were undertaken using both fixed-effect and random-effects models. We used the GRADE approach to assess the quality of evidence. We sought to assess the risk of random errors with trial sequential analysis. We included two trials from 1987 and 2004 with a total 148 participants who have had heart valve surgery. Both trials had a high risk of bias.There was insufficient evidence

  11. Changes in Left Ventricular Morphology and Function After Mitral Valve Surgery

    PubMed Central

    Shafii, Alexis E.; Gillinov, A. Marc; Mihaljevic, Tomislav; Stewart, William; Batizy, Lillian H.; Blackstone, Eugene H.

    2015-01-01

    Degenerative mitral valve disease is the leading cause of mitral regurgitation in North America. Surgical intervention has hinged on symptoms and ventricular changes that develop as compensatory ventricular remodeling takes place. In this study, we sought to characterize the temporal response of left ventricular (LV) morphology and function to mitral valve surgery for degenerative disease, and identify preoperative factors that influence reverse remodeling. From 1986–2007, 2,778 patients with isolated degenerative mitral valve disease underwent valve repair (n=2,607/94%) or replacement (n=171/6%) and had at least 1 postoperative transthoracic echocardiogram (TTE); 5,336 TTEs were available for analysis. Multivariable longitudinal repeated-measures analysis was performed to identify factors associated with reverse remodeling. LV dimensions decreased in the first year after surgery (end-diastolic from 5.7±0.80 to 4.9±1.4 cm; end-systolic from 3.4±0.71 to 3.1±1.4 cm). LV mass index decreased from 139±44 to 112±73 g·m−2. Reduction of LV hypertrophy was less pronounced in patients with greater preoperative left heart enlargement (P<.0001) and greater preoperative LV mass (P<.0001). Postoperative LV ejection fraction initially decreased from 58±7.0 to 53±20, increased slightly over the first postoperative year, and was negatively influenced by preoperative heart failure symptoms (P<.0001) and lower preoperative LV ejection fraction (P<.0001). Risk-adjusted response of LV morphology and function to valve repair and replacement was similar (P>.2). In conclusion, a positive response toward normalization of LV morphology and function after mitral valve surgery is greatest in the first year. The best response occurs when surgery is performed before left heart dilatation, LV hypertrophy, or LV dysfunction develop. PMID:22534055

  12. Non-cardiac surgery in patients with prosthetic heart valves: a 12 years experience.

    PubMed

    Akhtar, Raja Parvez; Abid, Abdul Rehman; Zafar, Hasnain; Gardezi, Syed Javed Raza; Waheed, Abdul; Khan, Jawad Sajid

    2007-10-01

    To study patients with mechanical heart valves undergoing non-cardiac surgery and their anticoagulation management during these procedures. It was a cohort study. The study was conducted at the Department of Cardiac Surgery, Punjab Institute of Cardiology, Lahore and Department of Surgery, Services Institute of Medical Sciences, Lahore, from September 1994 to June 2006. Patients with mechanical heart valves undergoing non-cardiac surgical operation during this period, were included. Their anticoagulation was monitored and anticoagulation related complications were recorded. In this study, 507 consecutive patients with a mechanical heart valve replacement were followed-up. Forty two (8.28%) patients underwent non-cardiac surgical operations of which 24 (57.1%) were for abdominal and non-abdominal surgeries, 5 (20.8%) were emergency and 19 (79.2%) were planned. There were 18 (42.9%) caesarean sections for pregnancies. Among the 24 procedures, there were 7(29.1%) laparotomies, 7(29.1%) hernia repairs, 2 (8.3%) cholecystectomies, 2 (8.3%) hysterectomies, 1(4.1%) craniotomy, 1(4.1%) spinal surgery for neuroblastoma, 1(4.1%) ankle fracture and 1(4.1%) carbuncle. No untoward valve or anticoagulation related complication was seen during this period. Patients with mechanical valve prosthesis on life-long anticoagulation, if managed properly, can undergo any type of non-cardiac surgical operation with minimal risk.

  13. Society of Thoracic Surgeons 2008 cardiac risk models predict in-hospital mortality of heart valve surgery in a Chinese population: a multicenter study.

    PubMed

    Wang, Lv; Lu, Fang-Lin; Wang, Chong; Tan, Meng-Wei; Xu, Zhi-yun

    2014-12-01

    The Society of Thoracic Surgeons 2008 cardiac surgery risk models have been developed for heart valve surgery with and without coronary artery bypass grafting. The aim of our study was to evaluate the performance of Society of Thoracic Surgeons 2008 cardiac risk models in Chinese patients undergoing single valve surgery and the predicted mortality rates of those undergoing multiple valve surgery derived from the Society of Thoracic Surgeons 2008 risk models. A total of 12,170 patients underwent heart valve surgery from January 2008 to December 2011. Combined congenital heart surgery and aortal surgery cases were excluded. A relatively small number of valve surgery combinations were excluded. The final research population included the following isolated heart valve surgery types: aortic valve replacement, mitral valve replacement, and mitral valve repair. The following combined valve surgery types were included: mitral valve replacement plus tricuspid valve repair, mitral valve replacement plus aortic valve replacement, and mitral valve replacement plus aortic valve replacement and tricuspid valve repair. Evaluation was performed by using the Hosmer-Lemeshow test and C-statistics. Data from 9846 patients were analyzed. The Society of Thoracic Surgeons 2008 cardiac risk models showed reasonable discrimination and poor calibration (C-statistic, 0.712; P = .00006 in Hosmer-Lemeshow test). Society of Thoracic Surgeons 2008 models had better discrimination (C-statistic, 0.734) and calibration (P = .5805) in patients undergoing isolated valve surgery than in patients undergoing multiple valve surgery (C-statistic, 0.694; P = .00002 in Hosmer-Lemeshow test). Estimates derived from the Society of Thoracic Surgeons 2008 models exceeded the mortality rates of multiple valve surgery (observed/expected ratios of 1.44 for multiple valve surgery and 1.17 for single valve surgery). The Society of Thoracic Surgeons 2008 cardiac surgery risk models performed well when predicting the

  14. Valve surgery in active infective endocarditis: a simple score to predict in-hospital prognosis.

    PubMed

    Martínez-Sellés, Manuel; Muñoz, Patricia; Arnáiz, Ana; Moreno, Mar; Gálvez, Juan; Rodríguez-Roda, Jorge; de Alarcón, Arístides; García Cabrera, Emilio; Fariñas, María C; Miró, José M; Montejo, Miguel; Moreno, Alfonso; Ruiz-Morales, Josefa; Goenaga, Miguel A; Bouza, Emilio

    2014-07-15

    Surgery for infective endocarditis (IE) is associated with high mortality. Our objectives were to describe the experience with surgical treatment for IE in Spain, and to identify predictors of in-hospital mortality. Prospective cohort of 1000 consecutive patients with IE. Data were collected in 26 Spanish hospitals. Surgery was performed in 437 patients (43.7%). Patients treated with surgery were younger and predominantly male. They presented fewer comorbid conditions and more often had negative blood cultures and heart failure. In-hospital mortality after surgery was lower than in the medical therapy group (24.3 vs 30.7%, p=0.02). In patients treated with surgery, endocarditis involved a native valve in 267 patients (61.1%), a prosthetic valve in 122 (27.9%), and a pacemaker lead with no clear further valve involvement in 48 (11.0%). The most common aetiologies were Staphylococcus (186, 42.6%), Streptococcus (97, 22.2%), and Enterococcus (49, 11.2%). The main indications for surgery were heart failure and severe valve regurgitation. A risk score for in-hospital mortality was developed using 7 prognostic variables with a similar predictive value (OR between 1.7 and 2.3): PALSUSE: prosthetic valve, age ≥ 70, large intracardiac destruction, Staphylococcus spp, urgent surgery, sex [female], EuroSCORE ≥ 10. In-hospital mortality ranged from 0% in patients with a PALSUSE score of 0 to 45.4% in patients with PALSUSE score >3. The prognosis of IE surgery is highly variable. The PALSUSE score could help to identify patients with higher in-hospital mortality. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Mild-to-moderate functional tricuspid regurgitation in patients undergoing mitral valve surgery.

    PubMed

    Ro, Sun Kyun; Kim, Joon Bum; Jung, Sung Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2013-11-01

    The decision to repair mild-to-moderate functional tricuspid regurgitation (TR) during mitral valve surgery remains controversial. We evaluated the effects of tricuspid valve (TV) repair for functional mild-to-moderate TR during mitral valve surgery. We enrolled 959 patients with mild-to-moderate functional TR who underwent mitral valve surgery with (repair group n = 431) or without (control group n = 528) concomitant TV repair from January 1994 to September 2010. There were no significant differences in early mortality or major morbidity rates. Median follow-up was 64.8 months (range, 0.03-203.6 months). After adjustment for baseline characteristics using a propensity score adjustment model, the repair group had similar risks for TV reoperation (hazard ratio [HR], 0.46; 95% confidence interval [CI], 0.10-2.07; P = .31); congestive heart failure (HR, 1.12; 95% CI, 0.37-3.36; P = .84); death (HR, 1.41; 95% CI, 0.82-2.42; P = .22); and the composite of death, TV reoperation, and congestive heart failure (HR, 1.24; 95% CI, 0.76-2.03; P = .39) compared with the control group. On multivariate Cox-regression analysis, old age, atrial fibrillation without a Maze procedure, diabetes mellitus, chronic renal failure, poor left ventricular ejection fraction, and redo surgery emerged as significant independent risk factors for the composite outcome of death, TV reoperation, and congestive heart failure. Early or late clinical benefits of concomitant TV repair for mild-to-moderate TR during mitral valve surgery were uncertain through a long-term follow-up of 959 patients. Several preoperative factors and the performance of Maze procedure for AF seem to be more important than TV repair in overall clinical outcomes. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. Tricuspid regurgitation and right ventricular function after mitral valve surgery with or without concomitant tricuspid valve procedure.

    PubMed

    Desai, Ravi R; Vargas Abello, Lina Maria; Klein, Allan L; Marwick, Thomas H; Krasuski, Richard A; Ye, Ying; Nowicki, Edward R; Rajeswaran, Jeevanantham; Blackstone, Eugene H; Pettersson, Gösta B

    2013-11-01

    To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+ (100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+ or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant

  17. Physical activity increases survival after heart valve surgery.

    PubMed

    Lund, K; Sibilitz, K L; Berg, S K; Thygesen, L C; Taylor, R S; Zwisler, A D

    2016-09-01

    Increased physical activity predicts survival and reduces risk of readmission in patients with coronary heart disease. However, few data show how physical activity is associated with survival and readmission after heart valve surgery. Objective were to assess the association between physical activity levels 6-12 months after heart valve surgery and (1) survival, (2) hospital readmission 18-24 months after surgery and (3) participation in exercise-based cardiac rehabilitation. Prospective cohort study with registry data from The CopenHeart survey, The Danish National Patient Register and The Danish Civil Registration System of 742 eligible patients. Physical activity was quantified with the International Physical Activity Questionnaire and analysed using Kaplan-Meier analysis and Cox regression and logistic regression methods. Patients with a moderate to high physical activity level had a reduced risk of mortality (3 deaths in 289 patients, 1%) compared with those with a low physical activity level (13 deaths in 235 patients, 5.5%) with a fully adjusted HR of 0.19 (95% CI 0.05 to 0.70). In contrast, physical activity level was not associated with the risk of hospital readmission. Patients who participated in exercise-based cardiac rehabilitation (n=297) were more likely than the non-participants (n=200) to have a moderate or high physical activity level than a low physical activity level (fully adjusted OR: 1.52, 95% CI 1.03 to 2.24). Moderate to high levels of physical activity after heart valve surgery are positively associated with higher survival rates and participation in cardiac rehabilitation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Surgical outcomes in native valve infectious endocarditis: the experience of the Cardiovascular Surgery Department - Cluj-Napoca Heart Institute.

    PubMed

    Molnar, Adrian; Muresan, Ioan; Trifan, Catalin; Pop, Dana; Sacui, Diana

    2015-01-01

    The introduction of Duke's criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. The patients' age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases - 21%), Staphylococcus Spp. (15 cases - 15%), and Enterococcus Spp. (9 cases - 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases - 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases - 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases - 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve - mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological examination of valve pieces excised during surgery was

  19. Predictors of survival in octogenarians after mitral valve surgery for degenerative disease: The Mitral Surgery in Octogenarians study.

    PubMed

    Chivasso, Pierpaolo; Bruno, Vito D; Farid, Shakil; Malvindi, Pietro Giorgio; Modi, Amit; Benedetto, Umberto; Ciulli, Franco; Abu-Omar, Yasir; Caputo, Massimo; Angelini, Gianni D; Livesey, Steve; Vohra, Hunaid A

    2018-04-01

    An increasing number of octogenarians are referred to undergo mitral valve surgery for degenerative disease, and percutaneous approaches are being increasingly used in this subgroup of patients. We sought to determine the survival and its predictors after Mitral Valve Surgery in Octogenarians (MiSO) in a multicenter UK study of high-volume specialized centers. Pooled data from 3 centers were collected retrospectively. To identify the predictors of short-term composite outcome of 30 days mortality, acute kidney injury, and cerebrovascular accident, a multivariable logistic regression model was developed. Multiple Cox regression analysis was performed for late mortality. Kaplan-Meier curves were generated for long-term survival in various subsets of patients. Receiver operating characteristic analysis was done to determine the predictive power of the logistic European System for Cardiac Operative Risk Evaluation. A total of 247 patients were included in the study. The median follow-up was 2.9 years (minimum 0, maximum 14 years). A total of 150 patients (60.7%) underwent mitral valve repair, and 97 patients (39.3%) underwent mitral valve replacement. Apart from redo cardiac surgery (mitral valve repair 6 [4%] vs mitral valve replacement 11 [11.3%], P = .04) and preoperative atrial fibrillation (mitral valve repair 79 [52.6%] vs mitral valve replacement 34 [35.1%], P < .01), there was no significant difference in terms of any other preoperative characteristics between the 2 groups. Patient operative risk, as estimated by logistic European System for Cardiac Operative Risk Evaluation, was lower in the mitral valve repair group (10.2 ± 11.8 vs 13.7 ± 15.2 in mitral valve replacement; P = .07). No difference was found between groups for duration of cardiopulmonary bypass and aortic crossclamp times. The 30-day mortality for the whole cohort was 13.8% (mitral valve repair 4.7% vs mitral valve replacement 18.6%; P < .01). No differences were found in terms

  20. Robotic mitral valve surgery: overview, methodology, results, and perspective

    PubMed Central

    2016-01-01

    Robotic mitral valve repair began in 1998 and has advanced remarkably. It arose from an interest in reducing patient trauma by operating through smaller incisions with videoscopic assistance. In the United States, following two clinical trials, the FDA approved the daVinci Surgical System in 2002 for intra-cardiac surgery. This device has undergone three iterations, eventuating in the current daVinci XI. At present it is the only robotic device approved for mitral valve surgery. Many larger centers have adopted its use as part of their routine mitral valve repair armamentarium. Although these operations have longer perfusion and arrest times, complications have been either similar or less than other traditional methods. Preoperative screening is paramount and leads to optimal patient selection and outcomes. There are clear contraindications, both relative and absolute, that must be considered. Three-dimensional (3D) echocardiographic studies optimally guide surgeons in operative planning. Herein, we describe the selection criteria as well as our operative management during a robotic mitral valve repair. Major complications are detailed with tips to avoid their occurrence. Operative outcomes from the author’s series as well as those from the largest experiences in the United States are described. They show that robotic mitral valve repair is safe and effective, as well as economically reasonable due to lower costs of hospitalization. Thus, the future of this operative technique is bright for centers adopting the “heart team” approach, adequate clinical volume and a dedicated and experienced mitral repair surgeon. PMID:27942486

  1. Myocardial Protection and Financial Considerations of Custodiol Cardioplegia in Minimally Invasive and Open Valve Surgery.

    PubMed

    Hummel, Brian W; Buss, Randall W; DiGiorgi, Paul L; Laviano, Brittany N; Yaeger, Nalani A; Lucas, M Lee; Comas, George M

    Single-dose antegrade crystalloid cardioplegia with Custodiol-HTK (histidine-tryptophan-ketoglutarate) has been used for many years. Its safety and efficacy were established in experimental and clinical studies. It is beneficial in complex valve surgery because it provides a long period of myocardial protection with a single dose. Thus, valve procedures (minimally invasive or open) can be performed with limited interruption. The aim of this study is to compare the use of Custodiol-HTK cardioplegia with traditional blood cardioplegia in patients undergoing minimally invasive and open valve surgery. A single-institution, retrospective case-control review was performed on patients who underwent valve surgery in Lee Memorial Health System at either HealthPark Medical Center or Gulf Coast Medical Center from July 1, 2011, through March 7, 2015. A total of 181 valve cases (aortic or mitral) performed using Custodiol-HTK cardioplegia were compared with 181 cases performed with traditional blood cardioplegia. Each group had an equal distribution of minimally invasive and open valve cases. Right chest thoracotomy or partial sternotomy was performed on minimally invasive valve cases. Demographics, perioperative data, clinical outcomes, and financial data were collected and analyzed. Patient outcomes were superior in the Custodiol-HTK cardioplegia group for blood transfusion, stroke, and hospital readmission within 30 days (P < 0.05). No statistical differences were observed in the other outcomes categories. Hospital charges were reduced on average by $3013 per patient when using Custodiol-HTK cardioplegia. Use of Custodiol-HTK cardioplegia is safe and cost-effective when compared with traditional repetitive blood cardioplegia in patients undergoing minimally invasive and open valve surgery.

  2. Early results of robotically assisted mitral valve surgery: Analysis of the first 1000 cases.

    PubMed

    Gillinov, A Marc; Mihaljevic, Tomislav; Javadikasgari, Hoda; Suri, Rakesh M; Mick, Stephanie L; Navia, José L; Desai, Milind Y; Bonatti, Johannes; Khosravi, Mitra; Idrees, Jay J; Lowry, Ashley M; Blackstone, Eugene H; Svensson, Lars G

    2018-01-01

    The study objective was to assess the technical and process improvement and clinical outcomes of robotic mitral valve surgery by examining the first 1000 cases performed in a tertiary care center. We reviewed the first 1000 patients (mean age, 56 ± 10 years) undergoing robotic primary mitral valve surgery, including concomitant procedures (n = 185), from January 2006 to November 2013. Mitral valve disease cause was degenerative (n = 960, 96%), endocarditis (n = 26, 2.6%), rheumatic (n = 10, 1.0%), ischemic (n = 3, 0.3%), and fibroelastoma (n = 1, 0.1%). All procedures were performed via right chest access with femoral perfusion for cardiopulmonary bypass. Mitral valve repair was attempted in 997 patients (2 planned replacements and 1 resection of fibroelastoma), 992 (99.5%) of whom underwent valve repair, and 5 (0.5%) of whom underwent valve replacement. Intraoperative postrepair echocardiography showed that 99.7% of patients receiving repair (989/992) left the operating room with no or mild mitral regurgitation, and predischarge echocardiography showed that mitral regurgitation remained mild or less in 97.9% of patients (915/935). There was 1 hospital death (0.1%), and 14 patients (1.4%) experienced a stroke; stroke risk declined from 2% in the first 500 patients to 0.8% in the second 500 patients. Over the course of the experience, myocardial ischemic and cardiopulmonary bypass times (P < .0001), transfusion (P = .003), and intensive care unit and postoperative lengths of stay (P < .05) decreased. Robotic mitral valve surgery is associated with a high likelihood of valve repair and low operative mortality and morbidity. The combination of algorithm-driven patient selection and increased experience enhanced clinical outcomes and procedural efficiency. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. Surgical outcomes in native valve infectious endocarditis: the experience of the Cardiovascular Surgery Department – Cluj-Napoca Heart Institute

    PubMed Central

    MOLNAR, ADRIAN; MURESAN, IOAN; TRIFAN, CATALIN; POP, DANA; SACUI, DIANA

    2015-01-01

    Background and aims The introduction of Duke’s criteria and the improvement of imaging methods has lead to an earlier and a more accurate diagnosis of infectious endocarditis (IE). The options for the best therapeutic approach and the timing of surgery are still a matter of debate and require a close colaboration between the cardiologist, the infectionist and the cardiac surgeon. Methods We undertook a retrospective, descriptive study, spanning over a period of five years (from January 1st, 2007 to December 31st, 2012), on 100 patients who underwent surgery for native valve infectious endocarditis in our unit. Results The patients’ age varied between 13 and 77 years (with a mean of 54 years), of which 85 were males (85%). The main microorganisms responsible for IE were: Streptococcus Spp. (21 cases – 21%), Staphylococcus Spp. (15 cases – 15%), and Enterococcus Spp. (9 cases – 9%). The potential source of infection was identified in 26 patients (26%), with most cases being in the dental area (16 cases – 16%). The lesions caused by IE were situated in the left heart in 96 patients (96%), mostly on the aortic valve (50 cases – 50%). In most cases (82%) we found preexisting endocardial lesions which predisposed to the development of IE, most of them being degenerative valvular lesions (38 cases – 38%). We performed the following surgical procedures: surgery on a single valve - aortic valve replacement (40 cases), mitral valve replacement (19 cases), mitral valve repair (1 case), surgery on more than one valve – mitral and aortic valve replacement (20 cases), aortic and tricuspid valve replacement (1 case), aortic valve replacement with a mechanical valve associated with mitral valve repair (5 cases), aortic valve replacement with a biological valve associated with mitral valve repair (2 cases), and mitral valve replacement with a mechanical valve combined with De Vega procedure on the tricuspid valve (1 case). In 5 patients (5%) the bacteriological

  4. Outcomes of ring versus suture annuloplasty for tricuspid valve repair in patients undergoing mitral valve surgery.

    PubMed

    Shinn, Sung Ho; Dayan, Victor; Schaff, Hartzell V; Dearani, Joseph A; Joyce, Lyle D; Lahr, Brian; Greason, Kevin L; Stulak, John M; Daly, Richard C

    2016-08-01

    There is controversy regarding the comparative effectiveness of methods of tricuspid valve (TV) repair-prosthetic ring versus suture annuloplasty-in patients undergoing operation for primary mitral valve (MV) disease. In this study, we analyzed factors associated with patient survival and recurrent tricuspid regurgitation (TR) following TV repair and focused on results stratified by method of tricuspid valve repair. We reviewed patients who underwent TV repair with suture (De Vega) or flexible ring annuloplasties at the time of MV surgery from 1995 to 2010. Patients with prior cardiac or concomitant aortic valve operations were excluded. Propensity matching was performed to account for potential differences in baseline characteristics between the groups. Primary outcomes were long-term mortality and postoperative TR grade. In the overall study, there were 415 patients with median age 72 years (range, 63-78 years), from which 148 matched pairs were identified by propensity score analysis. In the overall cohort, patients in the ring annuloplasty group more often had preoperative transvenous pacemakers (P = .05), lower ejection fractions (P = .028), and more recent years of operation (P < .001). For patients who had De Vega suture annuloplasty, long-term mortality was not different from that of patients who had ring annuloplasty (hazard ratio, 0.93; 95% confidence interval, 0.67-1.30). Older age, preoperative diabetes, and preoperative right ventricular dysfunction were predictors for long-term mortality. Durability of the annuloplasty methods was similar with no significant difference in trend of recurrent TR grades over follow-up (P = .807). Etiology of mitral regurgitation was not associated with recurrent TR during follow-up (P = .857). Late survival and TV durability following concomitant TV repair during MV surgery did not differ with respect to TV repair technique. In this series of patients with repaired tricuspid valves, etiology of MV disease did

  5. Minimally invasive mitral valve surgery is associated with equivalent cost and shorter hospital stay when compared with traditional sternotomy.

    PubMed

    Atluri, Pavan; Stetson, Robert L; Hung, George; Gaffey, Ann C; Szeto, Wilson Y; Acker, Michael A; Hargrove, W Clark

    2016-02-01

    Mitral valve surgery is increasingly performed through minimally invasive approaches. There are limited data regarding the cost of minimally invasive mitral valve surgery. Moreover, there are no data on the specific costs associated with mitral valve surgery. We undertook this study to compare the costs (total and subcomponent) of minimally invasive mitral valve surgery relative to traditional sternotomy. All isolated mitral valve repairs performed in our health system from March 2012 through September 2013 were analyzed. To ensure like sets of patients, only those patients who underwent isolated mitral valve repairs with preoperative Society of Thoracic Surgeons scores of less than 4 were included in this study. A total of 159 patients were identified (sternotomy, 68; mini, 91). Total incurred direct cost was obtained from hospital financial records. Analysis demonstrated no difference in total cost (operative and postoperative) of mitral valve repair between mini and sternotomy ($25,515 ± $7598 vs $26,049 ± $11,737; P = .74). Operative costs were higher for the mini cohort, whereas postoperative costs were significantly lower. Postoperative intensive care unit and total hospital stays were both significantly shorter for the mini cohort. There were no differences in postoperative complications or survival between groups. Minimally invasive mitral valve surgery can be performed with overall equivalent cost and shorter hospital stay relative to traditional sternotomy. There is greater operative cost associated with minimally invasive mitral valve surgery that is offset by shorter intensive care unit and hospital stays. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  6. Minimally invasive aortic valve replacement surgery through lower half sternotomy

    PubMed Central

    Fenton, James R.

    2013-01-01

    Less invasive approaches to aortic valve surgery frequently rely upon the development of new technology and instrumentation. While not suitable for every patient requiring an aortic valve procedure, these less invasive operations can offer certain clinical benefits and are becoming an important part of the modern cardiothoracic surgeon’s skillset. A lower partial sternotomy approach provides excellent visualization of the operative field, efficient execution of the operation and many of the benefits of minimally invasive surgery. Importantly, the lower partial sternotomy requires no new or unusual instruments and presents a familiar view to the surgeon. The technique, therefore, lends itself well to being adapted and utilized quickly with a potentially shorter “learning curve” for maximal surgical flexibility and patient benefit. PMID:24251024

  7. A review of outcome following valve surgery for rheumatic heart disease in Australia.

    PubMed

    Russell, E Anne; Tran, Lavinia; Baker, Robert A; Bennetts, Jayme S; Brown, Alex; Reid, Christopher M; Tam, Robert; Walsh, Warren F; Maguire, Graeme P

    2015-09-23

    Globally, rheumatic heart disease (RHD) remains an important cause of heart disease. In Australia it particularly affects younger Indigenous and older non-Indigenous Australians. Despite its impact there is limited understanding of the factors influencing outcome following surgery for RHD. The Australian and New Zealand Society of Cardiac and Thoracic Surgeons Cardiac Surgery Database was analysed to assess outcomes following surgical procedures for RHD and non-RHD valvular disease. The association with demographics, co-morbidities, pre-operative status, valve(s) affected and operative procedure was evaluated. Outcome of 1384 RHD and 15843 non-RHD valve procedures was analysed. RHD patients had longer ventilation, experienced fewer strokes and had more readmissions to hospital and anticoagulant complications. Mortality following RHD surgery at 30 days was 3.1% (95% CI 2.2 - 4.3), 5 years 15.3% (11.7 - 19.5) and 10 years 25.0% (10.7 - 44.9). Mortality following non-RHD surgery at 30 days was 4.3% (95% CI 3.9 - 4.6), 5 years 17.6% (16.4 - 18.9) and 10 years 39.4% (33.0 - 46.1). Factors independently associated with poorer longer term survival following RHD surgery included older age (OR1.03/additional year, 95% CI 1.01 - 1.05), concomitant diabetes (OR 1.7, 95% CI 1.1 - 2.5) and chronic kidney disease (1.9, 1.2 - 2.9), longer invasive ventilation time (OR 1.7 if greater than median value, 1.1- 2.9) and prolonged stay in hospital (1.02/additional day, 1.01 - 1.03). Survival in Indigenous Australians was comparable to that seen in non-Indigenous Australians. In a large prospective cohort study we have demonstrated survival following RHD valve surgery in Australia is comparable to earlier studies. Patients with diabetes and chronic kidney disease, were at particular risk of poorer long-term survival. Unlike earlier studies we did not find pre-existing atrial fibrillation, being an Indigenous Australian or the nature of the underlying valve lesion were independent

  8. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    PubMed

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  9. Implementation of transcatheter aortic valve replacement in California: Influence on aortic valve surgery.

    PubMed

    Maximus, Steven; Milliken, Jeffrey C; Danielsen, Beate; Shemin, Richard; Khan, Junaid; Carey, Joseph S

    2018-04-01

    Transcatheter aortic valve replacement (TAVR) procedures were introduced in 2011. Initially, procedures were limited to patients who were not surgical candidates, but subsequently high-risk surgical candidates were considered for TAVR. The influence on aortic valve surgery in California is unknown. The California Office of Statewide Health Planning and Development hospitalized patient discharge database was queried for the years 2009 through 2014. isolated surgical aortic valve and aortic valve/coronary artery bypass graft (SAVR) and TAVR procedures were identified by International Classification of Diseases-9th revision clinical modification procedure codes. Seven TAVR programs were introduced in 2011, 12 in 2012, 3 in 2013, and 6 in 2014. SAVR procedure volumes were compared from the 2 years before institution with SAVR volumes during the year(s) after institution of the TAVR program in these 28 hospitals. Overall, surgical volumes increased during the first, second, and third years after implementation of TAVR procedures. Among 7 hospitals with 4-year programs, surgical volumes increased to a maximum of 15.5% during the third year, then began to decrease. The hospital performing the largest number of TAVR procedures showed a marked decrease in SAVR volume by the fourth year, suggesting a shift of SAVR candidates to TAVR. Among all hospitals with 4-year programs, TAVR exceeded SAVR procedures by the fourth year. In California overall, SAVR increased during 2011 through 2013, due primarily to increasing volume of isolated SAVR procedures. Statewide, isolated SAVR increased from a yearly average of 3111 procedures during 2009-2010 to 3592 (+15.5%) in 2013, then decreased slightly in 2014. SAVR plus coronary artery bypass graft procedures decreased during the same time period. After implementation of TAVR, hospital SAVR volumes increased moderately, then began to decrease by the fourth year, when TAVR volume exceeded SAVR. Surgical candidates may be identified

  10. Risks and Challenges of Surgery for Aortic Prosthetic Valve Endocarditis.

    PubMed

    Grubitzsch, Herko; Tarar, Waharat; Claus, Benjamin; Gabbieri, Davide; Falk, Volkmar; Christ, Torsten

    2018-03-01

    Prosthetic valve endocarditis is the most severe form of infective endocarditis. This study assessed the risks and challenges of surgery for aortic prosthetic valve endocarditis. In total, 116 consecutive patients (98 males, age 65.2±12.7years), who underwent redo-surgery for active aortic prosthetic valve endocarditis between 2000 and 2014, were reviewed. Cox regression analysis was used to identify factors for aortic root destructions as well as for morbidity and mortality. Median follow-up was 3.8 years (0-13.9 years). Aortic root destructions (42 limited and 29 multiple lesions) were associated with early prosthetic valve endocarditis and delayed diagnosis (≥14 d), but not with mortality. There were 16 (13.8%) early (≤30 d) and 32 (27.6%) late (>30 days) deaths. Survival at 1, 5, and 10 years was 72±4.3%, 56±5.4%, and 46±6.4%, respectively. The cumulative incidence of death, reinfection, and reoperation was 19.0% at 30days and 36.2% at 1year. Delayed diagnosis, concomitant procedures, and EuroSCORE II >20% were predictors for early mortality and need for mechanical circulatory support, age >70years, and critical preoperative state were predictors for late mortality. In their absence, survival at 10 years was 70±8.4%. Reinfections and reoperations occurred more frequently if ≥1 risk factor for endocarditis and aortic root destructions were present. At 10 years, freedom from reinfection and reoperation was 89±4.2% and 91±4.0%. The risks of death, reinfection, and reoperation are significant within the first year after surgery for aortic prosthetic valve endocarditis. Early diagnosis and aortic root destructions are the most important challenges, but advanced age, critical preoperative state, and the need for mechanical circulatory support determine long-term survival. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B

  11. Safety of minimally invasive mitral valve surgery without aortic cross-clamp.

    PubMed

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Kumar, Sathappan; Solenkova, Nataliya V; Kaiser, Clayton A; Greelish, James P; Balaguer, Jorge M; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Kim, Betty S; Byrne, John G

    2008-05-01

    We developed a technique for open heart surgery through a small (5 cm) right-anterolateral thoracotomy without aortic cross-clamp. One hundred and ninety-five consecutive patients (103 male and 92 female), age 69 +/- 8 years, underwent surgery between January 2006 and July 2007. Mean preoperative New York Heart Association function class was 2.2 +/- 0.7. Thirty-five patients (18%) had an ejection fraction 0.35 or less. Cardiopulmonary bypass was instituted through femoral (176 of 195, 90%), axillary (18 of 195, 9%), or direct aortic (1 of 195, 0.5%) cannulation. Under cold fibrillatory arrest (mean temperature 28.2 degrees C) without aortic cross-clamp, mitral valve repair (72 of 195, 37%), mitral valve replacement (117 of 195, 60%), or other (6 of 195, 3%) procedures were performed. Concomitant procedures included maze (45 of 195, 23%), patent foramen ovale closure (42 of 195, 22%) and tricuspid valve repair (16 of 195, 8%), or replacement (4 of 195, 2%). Thirty-day mortality was 3% (6 of 195). Duration of fibrillatory arrest, cardiopulmonary bypass, and "skin to skin" surgery were 88 +/- 32, 118 +/- 52, and 280 +/- 78 minutes, respectively. Ten patients (5%) underwent reexploration for bleeding and 44% did not receive any blood transfusions. Six patients (3%) sustained a postoperative stroke, eight (4%) developed low cardiac output syndrome, and two (1%) developed renal failure requiring hemodialysis. Mean length of hospital stay was 7 +/- 4.8 days. This simplified technique of minimally invasive open heart surgery is safe and easily reproducible. Fibrillatory arrest without aortic cross-clamping, with coronary perfusion against an intact aortic valve, does not increase the risk of stroke or low cardiac output. It may be particularly useful in higher risk patients in whom sternotomy with aortic clamping is less desirable.

  12. In-hospital cost comparison between percutaneous pulmonary valve implantation and surgery

    PubMed Central

    Mishra, Vinod; Lewandowska, Milena; Andersen, Jack Gunnar; Andersen, Marit Helen; Lindberg, Harald; Døhlen, Gaute; Fosse, Erik

    2017-01-01

    Abstract OBJECTIVES: Today, both surgical and percutaneous techniques are available for pulmonary valve implantation in patients with right ventricle outflow tract obstruction or insufficiency. In this controlled, non-randomized study the hospital costs per patient of the two treatment options were identified and compared. METHODS: During the period of June 2011 until October 2014 cost data in 20 patients treated with the percutaneous technique and 14 patients treated with open surgery were consecutively included. Two methods for cost analysis were used, a retrospective average cost estimate (overhead costs) and a direct prospective detailed cost acquisition related to each individual patient (patient-specific costs). RESULTS: The equipment cost, particularly the stents and valve itself was by far the main cost-driving factor in the percutaneous pulmonary valve group, representing 96% of the direct costs, whereas in the open surgery group the main costs derived from the postoperative care and particularly the stay in the intensive care department. The device-related cost in this group represented 13.5% of the direct costs. Length-of-stay-related costs in the percutaneous group were mean $3885 (1618) and mean $17 848 (5060) in the open surgery group. The difference in postoperative stay between the groups was statistically significant (P≤ 0.001). CONCLUSIONS: Given the high postoperative cost in open surgery, the percutaneous procedure could be cost saving even with a device cost of more than five times the cost of the surgical device. PMID:28007875

  13. Surgical ablation of atrial fibrillation during mitral-valve surgery.

    PubMed

    Gillinov, A Marc; Gelijns, Annetine C; Parides, Michael K; DeRose, Joseph J; Moskowitz, Alan J; Voisine, Pierre; Ailawadi, Gorav; Bouchard, Denis; Smith, Peter K; Mack, Michael J; Acker, Michael A; Mullen, John C; Rose, Eric A; Chang, Helena L; Puskas, John D; Couderc, Jean-Philippe; Gardner, Timothy J; Varghese, Robin; Horvath, Keith A; Bolling, Steven F; Michler, Robert E; Geller, Nancy L; Ascheim, Deborah D; Miller, Marissa A; Bagiella, Emilia; Moquete, Ellen G; Williams, Paula; Taddei-Peters, Wendy C; O'Gara, Patrick T; Blackstone, Eugene H; Argenziano, Michael

    2015-04-09

    Among patients undergoing mitral-valve surgery, 30 to 50% present with atrial fibrillation, which is associated with reduced survival and increased risk of stroke. Surgical ablation of atrial fibrillation has been widely adopted, but evidence regarding its safety and effectiveness is limited. We randomly assigned 260 patients with persistent or long-standing persistent atrial fibrillation who required mitral-valve surgery to undergo either surgical ablation (ablation group) or no ablation (control group) during the mitral-valve operation. Patients in the ablation group underwent further randomization to pulmonary-vein isolation or a biatrial maze procedure. All patients underwent closure of the left atrial appendage. The primary end point was freedom from atrial fibrillation at both 6 months and 12 months (as assessed by means of 3-day Holter monitoring). More patients in the ablation group than in the control group were free from atrial fibrillation at both 6 and 12 months (63.2% vs. 29.4%, P<0.001). There was no significant difference in the rate of freedom from atrial fibrillation between patients who underwent pulmonary-vein isolation and those who underwent the biatrial maze procedure (61.0% and 66.0%, respectively; P=0.60). One-year mortality was 6.8% in the ablation group and 8.7% in the control group (hazard ratio with ablation, 0.76; 95% confidence interval, 0.32 to 1.84; P=0.55). Ablation was associated with more implantations of a permanent pacemaker than was no ablation (21.5 vs. 8.1 per 100 patient-years, P=0.01). There were no significant between-group differences in major cardiac or cerebrovascular adverse events, overall serious adverse events, or hospital readmissions. The addition of atrial fibrillation ablation to mitral-valve surgery significantly increased the rate of freedom from atrial fibrillation at 1 year among patients with persistent or long-standing persistent atrial fibrillation, but the risk of implantation of a permanent pacemaker

  14. Reconstructive valve surgery within 10 days of stroke in endocarditis.

    PubMed

    Raman, Jai; Ballal, Apoorva; Hota, Bala; Mirza, Sara; Lai, David; Bleck, Thomas; Lateef, Omar

    2016-07-01

    The optimal timing of surgical treatment for infective endocarditis complicated by cerebrovascular events is controversial, largely due to the perceived risk of perioperative intracranial bleeding. Current guidelines suggest waiting 2 weeks between the diagnosis of stroke and surgery. The aim of this study was to investigate the clinical and neurological outcomes of early surgery following a stroke. This was a single-center retrospective analysis of 12 consecutive patients requiring surgery for infective endocarditis between 2011 and 2014 at Rush University Medical Center, with either ischemic (n = 6) and/or hemorrhagic (n = 6) cerebrovascular complications. All underwent computed tomographic angiography prior to early valve reconstructive surgery to identify potentially actionable neurological findings. Early valve surgery was performed for ongoing sepsis or persistent emboli. Neurologic risk and outcome were assessed pre- and postoperatively using the National Institutes of Health Stroke Scale and the Glasgow Outcome Scale, respectively. All 12 patients underwent surgical treatment within 10 days of the diagnosis of stroke. Mortality in the immediate postoperative period was 8%. Eleven of the 12 patients exhibited good neurological recovery in the immediate postoperative period, with a Glasgow Outcome Scale score ≥ 3. There was no correlation between duration of cardiopulmonary bypass and neurological outcomes. Early cardiac surgery in patients with infective endocarditis and stroke maybe lifesaving with a low neurological risk. Comprehensive neurovascular imaging may help in identifying patient-related risk factors. © The Author(s) 2016.

  15. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    PubMed

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Haemodynamic improvement of older, previously replaced mechanical mitral valves by removal of the subvalvular pannus in redo cardiac surgery.

    PubMed

    Kim, Jong Hun; Kim, Tae Youn; Choi, Jong Bum; Kuh, Ja Hong

    2017-01-01

    Patients requiring redo cardiac surgery for diseased heart valves other than mitral valves may show increased pressure gradients and reduced valve areas of previously placed mechanical mitral valves due to subvalvular pannus formation. We treated four women who had mechanical mitral valves inserted greater than or equal to 20 years earlier and who presented with circular pannus that protruded into the lower margin of the valve ring but did not impede leaflet motion. Pannus removal improved the haemodynamic function of the mitral valve. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Prevalence and Prediction of Obstructive Coronary Artery Disease in Patients Undergoing Primary Heart Valve Surgery.

    PubMed

    Cazelli, José Guilherme; Camargo, Gabriel Cordeiro; Kruczan, Dany David; Weksler, Clara; Felipe, Alexandre Rouge; Gottlieb, Ilan

    2017-10-01

    The prevalence of coronary artery disease (CAD) in valvular patients is similar to that of the general population, with the usual association with traditional risk factors. Nevertheless, the search for obstructive CAD is more aggressive in the preoperative period of patients with valvular heart disease, resulting in the indication of invasive coronary angiography (ICA) to almost all adult patients, because it is believed that coronary artery bypass surgery should be associated with valve replacement. To evaluate the prevalence of obstructive CAD and factors associated with it in adult candidates for primary heart valve surgery between 2001 and 2014 at the National Institute of Cardiology (INC) and, thus, derive and validate a predictive obstructive CAD score. Cross-sectional study evaluating 2898 patients with indication for heart surgery of any etiology. Of those, 712 patients, who had valvular heart disease and underwent ICA in the 12 months prior to surgery, were included. The P value < 0.05 was adopted as statistical significance. The prevalence of obstructive CAD was 20%. A predictive model of obstructive CAD was created from multivariate logistic regression, using the variables age, chest pain, family history of CAD, systemic arterial hypertension, diabetes mellitus, dyslipidemia, smoking, and male gender. The model showed excellent correlation and calibration (R² = 0.98), as well as excellent accuracy (ROC of 0.848; 95%CI: 0.817-0.879) and validation (ROC of 0.877; 95%CI: 0.830 - 0.923) in different valve populations. Obstructive CAD can be estimated from clinical data of adult candidates for valve repair surgery, using a simple, accurate and validated score, easy to apply in clinical practice, which may contribute to changes in the preoperative strategy of acquired heart valve surgery in patients with a lower probability of obstructive disease.

  18. Minimally invasive right lateral thoracotomy without aortic cross-clamping: an attractive alternative to repeat sternotomy for reoperative mitral valve surgery.

    PubMed

    Umakanthan, Ramanan; Petracek, Michael R; Leacche, Marzia; Solenkova, Nataliya V; Eagle, Susan S; Thompson, Annemarie; Ahmad, Rashid M; Greelish, James P; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Balaguer, Jorge M; Byrne, John G

    2010-03-01

    The study aim was to determine the safety and benefits of minimally invasive mitral valve surgery without aortic cross-clamping for mitral valve surgery after previous cardiac surgery. Between January 2006 and August 2008, a total of 90 consecutive patients (38 females, 52 males; mean age 66 +/- 9 years) underwent minimally invasive mitral valve surgery after having undergone previous cardiac surgery. Of these patients, 80 (89%) underwent mitral valve replacement and 10 (11%) mitral valve repair utilizing a small (5 cm) right lateral thoracotomy along the 4th or 5th intercostal space under fibrillatory arrest (mean temperature 28 +/- 2 degrees C). The predicted mortality, calculated using the Society of Thoracic Surgeons (STS) algorithm, was compared to the observed mortality. The mean ejection fraction was 45 +/- 13%, mean NYHA class 3 +/- 1, while 66 patients (73%) had previous coronary artery bypass grafting and 37 (41%) had previous valve surgery. Twenty-six patients (29%) underwent non-elective surgery. Cardiopulmonary bypass was instituted through axillary (n = 19), femoral (n = 70) or direct use aortic (n = 1) cannulation. Operative mortality was 2% (2/90), lower than the STS-predicted mortality of 7%. Three patients (3%) developed acute renal failure postoperatively, one patient (1%) required new-onset hemodialysis, and one (1%) developed postoperative stroke. No patients developed postoperative myocardial infarction. The mean postoperative packed red blood cell transfusion requirement at 48 h was 2 +/- 3 units. Minimally invasive right thoracotomy without aortic cross-clamping is an excellent alternative to conventional redo-sternotomy for reoperative mitral valve surgery. The present study confirmed that this technique is safe and effective in reducing operative mortality in high-risk patients undergoing reoperative cardiac surgery.

  19. A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in "real-world" patients with aortic stenosis and intermediate- to high-risk profile.

    PubMed

    Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry

    2015-12-01

    We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (P< .001) and peripheral vascular complications occurred in 0% of surgicalaortic valve replacement vs 0% of sutureless vs 9.8% transcatheter aortic valve replacement (P< .001). At 24-month follow-up, overall survival (surgical aortic valve replacement = 91.3% ± 2.4% vs sutureless = 94.9% ± 2.1% vs transcatheter aortic valve replacement = 79.5% ± 4.3%; P < .001) and survival free from the composite end point of major adverse cardiovascular events and periprosthetic regurgitation were significantly

  20. Heart valve surgery

    MedlinePlus

    ... with an artificial valve (this is called the Ross Procedure). This procedure may be useful for people ... valve that does not close all the way will allow blood to leak backwards. This is called ...

  1. Tricuspid regurgitation and right ventricular function after mitral valve surgery with or without concomitant tricuspid valve procedure

    PubMed Central

    Desai, Ravi R.; Vargas Abello, Lina Maria; Klein, Allan L.; Marwick, Thomas H.; Krasuski, Richard A.; Ye, Ying; Nowicki, Edward R.; Rajeswaran, Jeevanantham; Blackstone, Eugene H.; Pettersson, Gösta B.

    2014-01-01

    Objectives To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. Methods From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+(100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. Results In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. Conclusions In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and

  2. In-hospital and 1-year mortality in patients undergoing early surgery for prosthetic valve endocarditis.

    PubMed

    Lalani, Tahaniyat; Chu, Vivian H; Park, Lawrence P; Cecchi, Enrico; Corey, G Ralph; Durante-Mangoni, Emanuele; Fowler, Vance G; Gordon, David; Grossi, Paolo; Hannan, Margaret; Hoen, Bruno; Muñoz, Patricia; Rizk, Hussien; Kanj, Souha S; Selton-Suty, Christine; Sexton, Daniel J; Spelman, Denis; Ravasio, Veronica; Tripodi, Marie Françoise; Wang, Andrew

    2013-09-09

    There are limited prospective, controlled data evaluating survival in patients receiving early surgery vs medical therapy for prosthetic valve endocarditis (PVE). To determine the in-hospital and 1-year mortality in patients with PVE who undergo valve replacement during index hospitalization compared with patients who receive medical therapy alone, after controlling for survival and treatment selection bias. Participants were enrolled between June 2000 and December 2006 in the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), a prospective, multinational, observational cohort of patients with infective endocarditis. Patients hospitalized with definite right- or left-sided PVE were included in the analysis. We evaluated the effect of treatment assignment on mortality, after adjusting for biases using a Cox proportional hazards model that included inverse probability of treatment weighting and surgery as a time-dependent covariate. The cohort was stratified by probability (propensity) for surgery, and outcomes were compared between the treatment groups within each stratum. Valve replacement during index hospitalization (early surgery) vs medical therapy. In-hospital and 1-year mortality. Of the 1025 patients with PVE, 490 patients (47.8%) underwent early surgery and 535 individuals (52.2%) received medical therapy alone. Compared with medical therapy, early surgery was associated with lower in-hospital mortality in the unadjusted analysis and after controlling for treatment selection bias (in-hospital mortality: hazard ratio [HR], 0.44 [95% CI, 0.38-0.52] and lower 1-year mortality: HR, 0.57 [95% CI, 0.49-0.67]). The lower mortality associated with surgery did not persist after adjustment for survivor bias (in-hospital mortality: HR, 0.90 [95% CI, 0.76-1.07] and 1-year mortality: HR, 1.04 [95% CI, 0.89-1.23]). Subgroup analysis indicated a lower in-hospital mortality with early surgery in the highest surgical propensity quintile (21

  3. What Is Heart Valve Surgery?

    MedlinePlus

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  4. [Results of fistulizing and Ahmed valve surgery for treatment of refractory glaucoma].

    PubMed

    Bikbov, M M; Babushkin, A E; Chaĭka, O V; Orenburkina, O I; Matiukhina, E N

    2014-01-01

    Surgical results of 76 patients (76 eyes) aged 25-79 years with secondary refractory glaucoma were analyzed. The best hypotensive effect and visual functions integrity were achieved with Ahmed valve implantation (86.7% and 83.3% of cases respectively); after conventional fistulizing surgery the hypotensive effect was observed in 45.5%, noncompromised vision--in 54.5% of cases. Tunnel trabeculectomy with iridocycloretraction led to normalization of intraocular pressure and stabilization of visual functions in 81.3% and 68.8% of cases respectively and thus can be considered as an alternative to fistulizing surgery in patients with secondary refractory glaucoma. Uveal glaucoma is a relative contraindication to Ahmed valve implantation, while neovascular glaucoma is that to tunnel trabeculectomy with iridocycloretraction.

  5. Referral to Cardiac Rehabilitation After Percutaneous Coronary Intervention, Coronary Artery Bypass Surgery, and Valve Surgery: Data From the Clinical Outcomes Assessment Program.

    PubMed

    Beatty, Alexis L; Bradley, Steven M; Maynard, Charles; McCabe, James M

    2017-06-01

    Despite guideline recommendations that patients undergoing percutaneous coronary intervention (PCI), coronary artery bypass surgery, or valve surgery be referred to cardiac rehabilitation, cardiac rehabilitation is underused. The objective of this study was to examine hospital-level variation in cardiac rehabilitation referral after PCI, coronary artery bypass surgery, and valve surgery. We analyzed data from the Clinical Outcomes Assessment Program, a registry of all nonfederal hospitals performing PCI and cardiac surgery in Washington State. We included eligible PCI, coronary artery bypass surgery, and valve surgery patients from 2010 to 2015. We analyzed PCI and cardiac surgery separately by performing multivariable hierarchical logistic regression for the outcome of cardiac rehabilitation referral at discharge, clustered by hospital. Patient-level covariates included age, sex, race/ethnicity, comorbidities, and procedure indication/status. Cardiac rehabilitation referral was reported in 48% (34 047/71 556) of PCI patients and 91% (21 831/23 972) of cardiac surgery patients. The hospital performing the procedure was a stronger predictor of referral than any individual patient characteristic for PCI (hospital referral range 3%-97%; median odds ratio, 5.94; 95% confidence interval, 4.10-9.49) and cardiac surgery (range 54%-100%; median odds ratio, 7.09; 95% confidence interval, 3.79-17.80). Hospitals having an outpatient cardiac rehabilitation program explained only 10% of PCI variation and 0% of cardiac surgery variation. Cardiac rehabilitation referral at discharge was less prevalent after PCI than cardiac surgery. The strongest predictor of cardiac rehabilitation referral was the hospital performing the procedure. Efforts to improve cardiac rehabilitation referral should focus on increasing referral after PCI, especially in low referral hospitals. © 2017 American Heart Association, Inc.

  6. Patient perceptions of experience with cardiac rehabilitation after isolated heart valve surgery.

    PubMed

    Hansen, Tina B; Berg, Selina K; Sibilitz, Kirstine L; Zwisler, Ann D; Norekvål, Tone M; Lee, Anne; Buus, Niels

    2018-01-01

    Little evidence exists on whether cardiac rehabilitation is effective for patients after heart valve surgery. Yet, accepted recommendations for patients with ischaemic heart disease continue to support it. To date, no studies have determined what heart valve surgery patients prefer in a cardiac rehabilitation programme, and none have analysed their experiences with it. The purpose of this qualitative analysis was to gain insight into patients' experiences in cardiac rehabilitation, the CopenHeart VR trial. This trial specifically assesses patients undergoing isolated heart valve surgery. Semi-structured interviews were conducted with nine patients recruited from the intervention arm of the trial. The intervention consisted of a physical training programme and a psycho-educational intervention. Participants were interviewed three times: 2-3 weeks, 3-4 months and 8-9 months after surgery between April 2013 and October 2014. Data were analysed using qualitative thematic analysis. Participants had diverse needs and preferences. Two overall themes emerged: cardiac rehabilitation played an important role in (i) reducing insecurity and (ii) helping participants to take active personal responsibility for their health. Despite these benefits, participants experienced existential and psychological challenges and musculoskeletal problems. Participants also sought additional advice from healthcare professionals both inside and outside the healthcare system. Even though the cardiac rehabilitation programme reduced insecurity and helped participants take active personal responsibility for their health, they experienced existential, psychological and physical challenges during recovery. The cardiac rehabilitation programme had several limitations, having implications for designing future programmes.

  7. Interventional valve surgery: building a team and working together.

    PubMed

    Ruel, Marc; Dickie, Sean; Chow, Benjamin J W; Labinaz, Marino

    2010-01-01

    Transcatheter aortic valve implantation (TAVI) is a new modality that may change the therapeutic landscape in the management of aortic valve stenosis. Despite the excellent results of surgical aortic valve replacement, TAVI has the potential to revolutionize the treatment of elderly and high-risk patients with aortic stenosis. It therefore constitutes a new reality that cardiac surgeons have to acknowledge. As TAVI indications and techniques become better defined, the importance of a team approach to the implementation and performance of TAVI is becoming increasingly evident. The surgeon has a crucial role to play in the introduction, development, and sustainability of TAVI at any institution. In this article, we discuss the procedural technique involved in TAVI, as well as the cardiologist and heart surgeon individualities and team dynamics. We make a case for judicious team-based adoption of TAVI technologies, considering that evidence-based and health economics data are not yet available. We also illustrate how a team approach may lead to improved outcomes, better patient and institutional acceptance, and a better definition of the therapeutic niche of TAVI modalities, amid the excellent results of conventional aortic valve replacement surgery. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. Risk model of valve surgery in Japan using the Japan Adult Cardiovascular Surgery Database.

    PubMed

    Motomura, Noboru; Miyata, Hiroaki; Tsukihara, Hiroyuki; Takamoto, Shinichi

    2010-11-01

    Risk models of cardiac valve surgery using a large database are useful for improving surgical quality. In order to obtain accurate, high-quality assessments of surgical outcome, each geographic area should maintain its own database. The study aim was to collect Japanese data and to prepare a risk stratification of cardiac valve procedures, using the Japan Adult Cardiovascular Surgery Database (JACVSD). A total of 6562 valve procedure records from 97 participating sites throughout Japan was analyzed, using a data entry form with 255 variables that was sent to the JACVSD office from a web-based data collection system. The statistical model was constructed using multiple logistic regression. Model discrimination was tested using the area under the receiver operating characteristic curve (C-index). The model calibration was tested using the Hosmer-Lemeshow (H-L) test. Among 6562 operated cases, 15% had diabetes mellitus, 5% were urgent, and 12% involved preoperative renal failure. The observed 30-day and operative mortality rates were 2.9% and 4.0%, respectively. Significant variables with high odds ratios included emergent or salvage status (3.83), reoperation (3.43), and left ventricular dysfunction (3.01). The H-L test and C-index values for 30-day mortality were satisfactory (0.44 and 0.80, respectively). The results obtained in Japan were at least as good as those reported elsewhere. The performance of this risk model also matched that of the STS National Adult Cardiac Database and the European Society Database.

  9. Long-term echocardiographic follow-up of untreated 2+ functional tricuspid regurgitation in patients undergoing mitral valve surgery.

    PubMed

    Kusajima, Kunio; Fujita, Tomoyuki; Hata, Hiroki; Shimahara, Yusuke; Miura, Sayaka; Kobayashi, Junjiro

    2016-07-01

    Concomitant tricuspid valve surgery with mitral valve surgery is recommended for patients with severe functional tricuspid regurgitation (TR). However, the treatment for 2+ TR (mild TR) remains controversial. Here, we evaluated the long-term results of untreated 2+ TR in patients undergoing mitral valve surgery. We retrospectively reviewed the records of 96 patients with untreated 2+ TR among 885 patients who underwent mitral valve surgery from 2003 to 2010. Exclusion criteria were tricuspid valve surgery (TVS), emergency surgery, primary TR and pacemaker lead through the tricuspid valve. We assessed survival and freedom from heart failure. The freedom from 3+ (moderate) or 4+ (severe) TR was investigated by echocardiographic data at pre- and postoperative week 1, then at 1, 3, 5, 7 and 10 postoperative years, which were compared with those in patients who had 2+ TR preoperatively and underwent concomitant TVS in the same period (n = 47). The mean follow-up was 7.1 ± 2.7 years. There was no 30-day mortality. The survival rate was 97.5% at 5 years and 87.5% at 10 years. The independent risk factors for mortality were age (OR 1.2, P = 0.03) and left ventricular ejection fraction (OR 0.9, P = 0.03). Untreated 2+ TR improved transiently within the first postoperative year (P < 0.001), but progressed again in the mid- to long term. Freedom from ≥3+ TR was 64.2% at 5 years and 46.7% at 10 years, which was significantly lower than that from ≥3+ TR in patients who underwent concomitant TVS (P = 0.006). The independent risk factors for TR progression (≥3 + TR) were age (OR 1.1, P = 0.005), atrial fibrillation (OR 2.2, P = 0.04) and tricuspid annular diameter (TAD) index (mm/m(2); OR 1.1, P = 0.02). Receiver operating characteristic curves showed that the optimal TAD index cut-off value was 21.0 for long-term survival [area under the curve (AUC) = 0.72] and 21.2 for TR progression (AUC = 0.64). Although untreated, 2+ TR significantly improved after mitral valve

  10. Heart valve surgery - series (image)

    MedlinePlus

    ... heart valves are either natural (biologic) or artificial (mechanical). Natural valves are from human donors (cadavers), modified ... artificial valves will require anticoagulation. The advantage of mechanical valves is that they last longer-thus, the ...

  11. Energy dynamics of the intraventricular vortex after mitral valve surgery.

    PubMed

    Nakashima, Kouki; Itatani, Keiichi; Kitamura, Tadashi; Oka, Norihiko; Horai, Tetsuya; Miyazaki, Shohei; Nie, Masaki; Miyaji, Kagami

    2017-09-01

    Mitral valve morphology after mitral valve surgery affects postoperative intraventricular flow patterns and long-term cardiac performance. We visualized ventricular flow by echocardiography vector flow mapping (VFM) to reveal the impact of different mitral valve procedures. Eleven cases of mechanical mitral valve replacement (nine in the anti-anatomical and two in the anatomical position), three bioprosthetic mitral valve replacements, and four mitral valve repairs were evaluated. The mean age at the procedure was 57.4 ± 17.8 year, and the echocardiography VFM in the apical long-axis view was performed 119.9 ± 126.7 months later. Flow energy loss (EL), kinetic pressure (KP), and the flow energy efficiency ratio (EL/KP) were measured. The cases with MVR in the anatomical position and with valve repair had normal vortex directionality ("Clockwise"; N = 6), whereas those with MVR in the anti-anatomical position and with a bioprosthetic mitral valve had the vortex in the opposite direction ("Counterclockwise"; N = 12). During diastole, vortex direction had no effect on EL ("Clockwise": 0.080 ± 0.025 W/m; "Counterclockwise": 0.083 ± 0.048 W/m; P = 0.31) or KP ("Clockwise": 0.117 ± 0.021 N; "Counterclockwise": 0.099 ± 0.057 N; P = 0.023). However, during systole, the EL/KP ratio was significantly higher in the "Counterclockwise" vortex than that in the "Clockwise" vortex (1.056 ± 0.463 vs. 0.617 ± 0.158; P = 0.009). MVP and MVR with a mechanical valve in the anatomical position preserve the physiological vortex, whereas MVR with a mechanical valve in the anti-anatomical position and a bioprosthetic mitral valve generate inefficient vortex flow patterns, resulting in a potential increase in excessive cardiac workload.

  12. Cardiac rehabilitation increases physical capacity but not mental health after heart valve surgery: a randomised clinical trial.

    PubMed

    Sibilitz, Kirstine L; Berg, Selina K; Rasmussen, Trine B; Risom, Signe Stelling; Thygesen, Lau C; Tang, Lars; Hansen, Tina B; Johansen, Pernille Palm; Gluud, Christian; Lindschou, Jane; Schmid, Jean Paul; Hassager, Christian; Køber, Lars; Taylor, Rod S; Zwisler, Ann-Dorthe

    2016-12-15

    The evidence for cardiac rehabilitation after valve surgery remains sparse. Current recommendations are therefore based on patients with ischaemic heart disease. The aim of this randomised clinical trial was to assess the effects of cardiac rehabilitation versus usual care after heart valve surgery. The trial was an investigator-initiated, randomised superiority trial (The CopenHeart VR trial, VR; valve replacement or repair). We randomised 147 patients after heart valve surgery 1:1 to 12 weeks of cardiac rehabilitation consisting of physical exercise and monthly psycho-educational consultations (intervention) versus usual care without structured physical exercise or psycho-educational consultations (control). Primary outcome was physical capacity measured by VO 2 peak and secondary outcome was self-reported mental health measured by Short Form-36. 76% were men, mean age 62 years, with aortic (62%), mitral (36%) or tricuspid/pulmonary valve surgery (2%). Cardiac rehabilitation compared with control had a beneficial effect on VO 2 peak at 4 months (24.8 mL/kg/min vs 22.5 mL/kg/min, p=0.045) but did not affect Short Form-36 Mental Component Scale at 6 months (53.7 vs 55.2 points, p=0.40) or the exploratory physical and mental outcomes. Cardiac rehabilitation increased the occurrence of self-reported non-serious adverse events (11/72 vs 3/75, p=0.02). Cardiac rehabilitation after heart valve surgery significantly improves VO 2 peak at 4 months but has no effect on mental health and other measures of exercise capacity and self-reported outcomes. Further research is needed to justify cardiac rehabilitation in this patient group. NCT01558765, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Clinical Implication of Transaortic Mitral Pannus Removal During Repeat Cardiac Surgery for Patients With Mechanical Mitral Valve.

    PubMed

    Park, Byungjoon; Sung, Kiick; Park, Pyo Won

    2018-01-25

    This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (P<0.001). No mechanical valve malfunction was apparent on last echocardiography. TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.

  14. Results of endocardial radiofrequency ablation of atrial fibrillation during mitral valve surgery.

    PubMed

    Demirkilic, U; Bolcal, C; Gunay, C; Doganci, S; Temizkan, V; Kuralay, E; Tatar, H

    2006-08-01

    The aim of the study is to evaluate the efficacy of thermocontrolled endocardial radiofrequency (RF) ablation for the patients with mitral valve disorder and associated chronic atrial fibrillation during mitral valve replacement operation. Between February 2002 and January 2004, 43 patients with mitral valve disease and associated chronic atrial fibrillation underwent mitral valve replacement and thermocontrolled endocardial RF ablation with Cobra RF system flexible probe at Gulhane Military Academy of Medicine, Department of Cardiovascular Surgery. Eighteen of the patients (41.8%) were males, while the remaining 25 (58.2%) were females. The average age of the patients was 44+/-14.21 (18-66) years. Functional capacity of the patients was class II in 15 (34. 9%), class III in 24 (55.8%), class IV in 4 (9.3%) according to the NYHA classification. At the preoperative period all of the patients were evaluated routinely by twelve-lead ECG, chest film and transthoracic echocardiography (TTE). For the patients over 40 years of age, we performed additional coronary angiography to delineate any coronary lesions. The patients were evaluated at months 1, 3, 6 and annually by twelve-lead ECG, TTE and holter monitoring after discharge. There were not any complications related to the performed technique. No operative and hospital mortality were recorded. At the follow-up period for 35 of 43 patients (81.4%) sinus rhythm was restored. The mean follow-up time was 24.3+/-11.2 (12-35) months. Endocardial RF ablation especially during mitral valve surgery is a simple technique to be performed. Early and midterm results of the cohort are satisfying.

  15. Minimal access surgery for mitral valve endocarditis.

    PubMed

    Barbero, Cristina; Marchetto, Giovanni; Ricci, Davide; Mancuso, Samuel; Boffini, Massimo; Cecchi, Enrico; De Rosa, Francesco Giuseppe; Rinaldi, Mauro

    2017-08-01

    Minimal access mitral valve surgery (MVS) has already proved to be feasible and effective with low perioperative mortality and excellent long-term outcomes. However, experience in more complex valve diseases such as infective endocarditis (IE) still remains limited. The aim of this retrospective study was to evaluate early and long-term results of minimal access MVS for IE. Data were entered into a dedicated database. Analysis was performed retrospectively for the 8-year period between January 2007 and April 2015. During the study period, 35 consecutive patients underwent minimal access MVS for IE at our department. Twenty-four had diagnosis of native MV endocarditis (68.6%) and 11 of mitral prosthesis endocarditis (31.4%).Thirty patients underwent early MVS (85.7%), and 5 patients were operated after the completion of antibiotic treatment (14.3%). Seven patients underwent MV repair (20%), 17 patients underwent MV replacement (48.6%), and 11 patients underwent mitral prosthesis replacement (31.4%). Thirty-day mortality was 11.4% (4 patients). No neurological or vascular complications were reported. One patient underwent reoperation for prosthesis IE relapse after 37 days. Overall actuarial survival rate at 1 and 5 years was 83%; freedom from MV reoperation and/or recurrence of IE at 1 and 5 years was 97%. Minimally invasive MVS for IE is feasible and associated with good early and long-term results. Preoperative accurate patient selection and transoesophageal echocardiography evaluation is mandatory for surgical planning. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Comparison of superior septal approach with left atriotomy in mitral valve surgery

    PubMed Central

    Aydin, Ebuzer; Arslan, Akin; Ozkokeli, Mehmet

    2014-01-01

    Objective In this study, we aimed to compare clinical outcomes of superior transseptal approach with the conventional left atriotomy in patients undergoing mitral valve surgery. Methods Between January 2010 and November 2012, a total of 91 consecutive adult patients (39 males, 52 females; mean age: 54.0±15.4 years; range, 16 to 82 years) who underwent mitral valve surgery in the Division of Cardiovascular Surgery at Koşuyolu Training Hospital were included. The patients were randomized to either superior transseptal approach (n=47) or conventional left atriotomy (n=44). Demographic characteristics of the patients, comorbidities, additional interventions, intraoperational data, pre- and postoperative electrophysiological study findings, and postoperative complications were recorded. Results Of all patients, 86.7% (n=79) were in New York Heart Association Class III, while 12 were in New York Heart Association Class IV. All patients underwent annuloplasty (42.9%) or valve replacement surgery (57.1%). There was no significant difference in pre- and postoperative electrocardiogram findings between the groups. Change from baseline in the cardiac rhythm was statistically significant in superior transseptal approach group alone (P<0.001). There was no statistically significant difference in mortality rate between the groups. Permanent pacemaker implantation was performed in 10.6% of the patients in superior transseptal approach group and 4.5% in the conventional left atriotomy group. No statistically significant difference in bleeding, total length of hospital and intensive care unit stay, the presence of low cardiac output syndrome was observed between the groups. Conclusion Our study results suggest that superior transseptal approach does not lead to serious or fatal adverse effects on sinus node function or atrial vulnerability, compared to conventional approach. PMID:25372911

  17. Preoperative Aspirin Does Not Increase Transfusion or Reoperation in Isolated Valve Surgery.

    PubMed

    Goldhammer, Jordan E; Herman, Corey R; Berguson, Mark W; Torjman, Marc C; Epstein, Richard H; Sun, Jian-Zhong

    2017-10-01

    Preoperative aspirin has been studied in patients undergoing isolated coronary artery bypass graft surgery. However, there is a paucity of clinical data available evaluating perioperative aspirin in other cardiac surgical procedures. This study was designed to investigate the effects of aspirin on bleeding and transfusion in patients undergoing non-emergent, isolated, heart valve repair or replacement. Retrospective, cohort study. Academic medical center. A total of 694 consecutive patients having non-emergent, isolated, valve repair or replacement surgery at an academic medical center were identified. Of the 488 patients who met inclusion criteria, 2 groups were defined based on their preoperative use of aspirin: those taking (n = 282), and those not taking (n = 206) aspirin within 5 days of surgery. Binary logistic regression was used to examine relationships among demographic and clinical variables. No significant difference was found between the aspirin and non-aspirin groups with respect to the percentage receiving red blood cell (RBC) transfusion, mean RBC units transfused in those who required transfusion, massive transfusion of RBC, or amounts of fresh frozen plasma, cryoprecipitate, or platelets. Aspirin was not associated with an increase in the rate of re-exploration for bleeding (5.3% v 6.3%, p = 0.478). Major adverse cardiocerebral events (MACE), 30-day mortality, and 30-day readmission rates were not statistically different between the aspirin-and non-aspirin-treated groups. Preoperative aspirin therapy in elective, isolated, valve surgery did not result in an increase in transfusion or reoperation for bleeding and was not associated with reduced readmission rate, MACE, or 30-day mortality. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Mitral valve surgery - minimally invasive

    MedlinePlus

    ... flow. Your valve has developed an infection (infectious endocarditis). You have severe mitral valve prolapse that is ... function. Damage to your heart valve from infection (endocarditis). A minimally invasive procedure has many benefits. There ...

  19. Early and Mid-Term Outcome of Pediatric Congenital Mitral Valve Surgery

    PubMed Central

    Baghaei, Ramin; Tabib, Avisa; Jalili, Farshad; Totonchi, Ziae; Mahdavi, Mohammad; Ghadrdoost, Behshid

    2015-01-01

    Background: Congenital lesions of the mitral valve are relatively rare and are associated with a wide spectrum of cardiac malformations. The surgical management of congenital mitral valve malformations has been a great challenge. Objectives: The aim of this study was to evaluate the early and intermediate-term outcome of congenital mitral valve (MV) surgery in children and to identify the predictors for poor postoperative outcomes and death. Patients and Methods: In this retrospective study, 100 consecutive patients with congenital MV disease undergoing mitral valve surgery were reviewed in 60-month follow-up (mean, 42.4 ± 16.4 months) during 2008 - 2013. Twenty-six patients (26%) were under one-year old. The mean age and weight of the patients were 41.63 ± 38.18 months and 11.92 ± 6.12 kg, respectively. The predominant lesion of the mitral valve was MV stenosis (MS group) seen in 21% and MR (MR group) seen in 79% of the patients. All patients underwent preoperative two-dimensional echocardiography and then every six months after surgery Results: Significant improvement in degree of MR was noted in all patients with MR during postoperative and follow-up period in both patients with or without atrioventricular septal defect (AVSD) (P = 0.045 in patients with AVSD and P = 0.008 in patients without AVSD). Decreasing trend of mean gradient (MG) in MS group was statistically significant (P = 0.005). In patients with MR, the mean pulmonary artery pressure (PAP) had improved postoperatively (P < 0.001). Although PAP in patients with MV stenosis was reduced, this reduction was not statistically significant (P = 0.17). In-hospital mortality was 7%. Multivariate analysis demonstrated that age (P < 0.001), weight (P < 0.001), and pulmonary stenosis (P = 0.03) are strong predictors for mortality. Based on the echocardiography report at the day of discharge from hospital, surgical results were optimal (up to moderate degree for MR group and up to mild degree for MS group) in

  20. Mitral valve surgery - open

    MedlinePlus

    ... place. There are two types of mitral valves: Mechanical, made of man-made (synthetic) materials, such as ... Mechanical heart valves last a lifetime. However, blood clots may develop on them. This can cause them ...

  1. Intracranial mycotic aneurysm is associated with cerebral bleeding post-valve surgery for infective endocarditis.

    PubMed

    Kume, Yuta; Fujita, Tomoyuki; Fukushima, Satsuki; Shimahara, Yusuke; Matsumoto, Yorihiko; Yamashita, Kizuku; Kawamoto, Naonori; Kobayashi, Junjiro

    2018-04-26

    The presence of cerebral haemorrhage (CH) preoperatively is a risk factor of in-hospital cerebrovascular complications post-valve surgery for acute infective endocarditis. However, factors related to cerebrovascular complications in the long term are poorly understood. We reviewed a series of these patients to investigate risk factors of in-hospital and long-term outcomes. An institutional series of 148 patients who underwent valve surgery for active infective endocarditis between 2000 and 2016 were enrolled. Patients were divided into 2 groups based on the presence of preoperative CH:CH group (n = 25) and non-CH group (n = 123). Of them, 14 (10%) patients were preoperatively diagnosed with mycotic aneurysm (MA). The 30-day mortality was 5% with no difference between the 2 groups. The 5-year survival rate was 92% in the CH group and 77% in the non-CH group. Freedom from CH at 5 years was 92% in the CH group and 97% in the non-CH group. There was no difference in the postoperative haemorrhage rate between patients who had surgery within 14 days from the onset of CH and those who had surgery after 14 days. Freedom from CH at 5 years was 99% in patients without MA and 71% in those with MA. The presence of MA preoperatively was the only independent risk factor of postoperative CH (P = 0.002). Valve surgery for acute infective endocarditis is safe, even in patients with CH preoperatively, regardless of the timing of surgery. Patients with intracranial MA are associated with postoperative CH in the hospital and long term.

  2. Exercise-based cardiac rehabilitation after heart valve surgery: cost analysis of healthcare use and sick leave.

    PubMed

    Hansen, T B; Zwisler, A D; Berg, S K; Sibilitz, K L; Thygesen, L C; Doherty, P; Søgaard, R

    2015-01-01

    Owing to a lack of evidence, patients undergoing heart valve surgery have been offered exercise-based cardiac rehabilitation (CR) since 2009 based on recommendations for patients with ischaemic heart disease in Denmark. The aim of this study was to investigate the impact of CR on the costs of healthcare use and sick leave among heart valve surgery patients over 12 months post surgery. We conducted a nationwide survey on the CR participation of all patients having undergone valve surgery between 1 January 2011 and 30 June 2011 (n=667). Among the responders (n=500, 75%), the resource use categories of primary and secondary healthcare, prescription medication and sick leave were analysed for CR participants (n=277) and non-participants (n=223) over 12 months. A difference-in-difference analysis was undertaken. All estimates were presented as the means per patient (95% CI) based on non-parametric bootstrapping of SEs. Total costs during the 12 months following surgery were €16 065 per patient (95% CI 13 730 to 18 399) in the CR group and €15 182 (12 695 to 17 670) in the non-CR group. CR led to 5.6 (2.9 to 8.3, p<0.01) more outpatient visits per patient. No statistically significant differences in other cost categories or total costs €1330 (-4427 to 7086, p=0.65) were found between the groups. CR, as provided in Denmark, can be considered cost neutral. CR is associated with more outpatient visits, but CR participation potentially offsets more expensive outpatient visits. Further studies should investigate the benefits of CR to heart valve surgery patients as part of a formal cost-utility analysis.

  3. Preoperative Aspirin Use and Lung Injury After Aortic Valve Replacement Surgery: A Retrospective Cohort Study.

    PubMed

    Mazzeffi, Michael; Kassa, Woderyelesh; Gammie, James; Tanaka, Kenichi; Roman, Philip; Zhan, Min; Griffith, Bartley; Rock, Peter

    2015-08-01

    Acute respiratory distress syndrome (ARDS) occurs uncommonly after cardiac surgery but has a mortality rate as high as 80%. Aspirin may prevent lung injury in at-risk patients by reducing platelet-neutrophil aggregates in the lung. We hypothesized that preoperative aspirin use would be associated with a decreased risk of ARDS after aortic valve replacement surgery. We performed a retrospective single-center cohort study that included all adult patients who had aortic valve replacement surgery during a 5-year period. The primary outcome variable was postoperative ARDS. The secondary outcome variable was nadir PaO2/FIO2 ratio during the first 72 hours after surgery. Both crude and propensity score-adjusted logistic regression analyses were performed to estimate the odds ratio for developing ARDS in aspirin users. Subgroups were analyzed to determine whether preoperative aspirin use might be associated with improved oxygenation in patients with specific risk factors for lung injury. Of the 375 patients who had aortic valve replacement surgery during the study period, 181 patients took aspirin preoperatively (48.3%) with most taking a dose of 81 mg (72.0%). There were 22 cases of ARDS in the cohort (5.5%). There was no significant difference in the rate of ARDS between aspirin users and nonusers (5.0% vs 6.7%, P = 0.52). There was also no significant difference in the nadir PaO2/FIO2 ratio between aspirin users and nonusers (P = 0.12). The crude odds ratio for ARDS in aspirin users was 0.725 (99% confidence interval, 0.229-2.289; P = 0.47), and the propensity score-adjusted odds ratio was 0.457 (99% confidence interval, 0.120-1.730; P = 0.13). Within the constraints of this analysis that included only 22 affected patients, preoperative aspirin use was not associated with a decreased incidence of ARDS after aortic valve replacement surgery or improved oxygenation.

  4. Aortic valve surgery - open

    MedlinePlus

    ... and into a large blood vessel called the aorta. The aortic valve separates the heart and aorta. The aortic valve opens so blood can flow ... to be able to see your heart and aorta. You may need to be connected to a ...

  5. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    PubMed

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  6. [Electroacupuncture intervention combined with general anesthesia for 80 cases of heart valve replacement surgery under cardiopulmonary bypass].

    PubMed

    Chi, Hao; Zhou, Wen-Xiong; Wu, Yao-Yao; Chen, Tong-Yu; Ge, Wen; Yuan, Lan; Shen, Wei-Dong; Zhou, Jia

    2014-02-01

    To determine whether electroacupuncture (EA) intervention combined with general anesthesia (GA) strategy can reduce early post-operative morbidity and medical costs in patients undergoing heart valve replacement operation under cardiopulmonary bypass. A total of 160 heart valve replacement surgery patients undergoing cardiopulmonary bypass were randomly divided into GA and EA + GA groups (n = 80 in each group). Patients of the GA group were given with intravenous injection of Fentanyl, Midazolam, Vecuronium Bromide, etc. and routine tracheal intubation. EA (3-4 Hz, 2.0-2.2 mA) was applied to bilateral Zhongfu (LU 1), Chize (LU 5) and Ximen (PC 4) beginning about 20 mm before the surgery in the EA + GA group. Endotracheal intubation was not employed but only prepared as a standby for patients of the EA + GA group. The dosage of narcotic drugs, duration of surgery, duration of aertic blockage, rate of cardiac re-beating, volumes of post-operative blood transfusion, discharge volume, cases of post-operative pulmonary infection, vocal cord injury, and the time of first bed-off, first eating and duration in intensive care unit (IOU) residence. etc. were recorded. The successful rates of heart valve replacement surgery were similar in both GA and EA + GA groups. Compared with the GA group, the dosages of Fentanyl, Midazolam and Vecuronium of the EA + GA group were significantly lower (P < 0.05, P < 0.01), the numbers of patients needing blood-transfusion, antibiotics treatment, and suffering from pulmonary infection were fewer, the time of first bed-off and duration of hospitalizetion and IOU residence were considerably shorter (P < 0.05, P < 0.01) and the total medical cost was obviously lower (P < 0.05) in the EA + GA group. EA combined with general anesthesia strategy for heart valve replacement surgery without endotracheal intubation is safe and can reduce post-operative morbidity and medical costs in patients undergoing heart valve replacement surgery under

  7. Options for Heart Valve Replacement

    MedlinePlus

    ... which may include human or animal donor tissue) Ross Procedure — “Borrowing” your healthy valve and moving it ... Considerations for Surgery Medications Valve Repair Valve Replacement - Ross Procedure - Newer Surgery Options - What is TAVR? - Types ...

  8. Is minimally invasive mitral valve repair with artificial chords reproducible and applicable in routine surgery?

    PubMed

    Panos, Aristotelis; Vlad, Sylvio; Milas, Fotios; Myers, Patrick O

    2015-06-01

    Traditional resectional techniques and chordal transfer are difficult to apply in video-assisted mitral valve repair. Using artificial chords appears easier in this setting. The purpose of this study was to review the effectiveness and reproducibility of neochordal repair as a routine approach to minimally invasive mitral repair, and to assess the stability of neochord implantation using the figure-of-eight suture without pledgets in this setting. This is a retrospective review of all patients who underwent minimally invasive video-assisted mitral valve repair from 2008 to 2013. The primary endpoints were recurrent mitral regurgitation and reoperation. A total of 426 consecutive patients were included during the study period, with a mean age of 55 ± 18 years. Neochords were used in all patients, and in association with leaflet resection in 47 patients. One patient was not repairable and underwent valve replacement (repair rate, 99.8%). Fifteen patients had Grade I (3.5%) regurgitation, whereas the remainder had none. Patients were fast-tracked, with 25% extubated in the operation theatre and the remainder within 6 h. There were 5 deaths within 30 days (1.2%). Follow-up ranged 3-60 months, during which all of the patients remained with no or trace mitral regurgitation. No de-insertion or rupture of any neochords was found, and no patients required a reoperation. Minimally invasive mitral valve repair using neochords provided a high rate of repair, reproducible results in a routine cardiac surgery setting and stable repair during follow-up. This has become our preferred technique for mitral valve surgery. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Minimally invasive mitral valve surgery through right mini-thoracotomy: recommendations for good exposure, stable cardiopulmonary bypass, and secure myocardial protection.

    PubMed

    Ito, Toshiaki

    2015-07-01

    An apparent advantage of minimally invasive mitral surgery through right mini-thoracotomy is cosmetic appearance. Possible advantages of this procedure are a shorter ventilation time, shorter hospital stay, and less blood transfusion. With regard to hard endpoints, such as operative mortality, freedom from reoperation, or cardiac death, this method is reportedly equivalent, but not superior, to the standard median sternotomy technique. However, perfusion-related complications (e.g., stroke, vascular damage, and limb ischemia) tend to occur more frequently in minimally invasive technique than with the standard technique. In addition, valve repair through a small thoracotomy is technically demanding. Therefore, screening out patients who are not appropriate for performing minimally invasive surgery is the first step. Vascular disease and inadequate anatomy can be evaluated with contrast-enhanced computed tomography. Peripheral cannulation should be carefully performed, using transesophageal echocardiography guidance. Preoperative detailed planning of the valve repair process is desirable because every step is time-consuming in minimally invasive surgery. Three-dimensional echocardiography is a powerful tool for this purpose. For satisfactory exposure and detailed observation of the valve, a special left atrial retractor and high-definition endoscope are useful. Valve repair can be performed in minimally invasive surgery as long as cardiopulmonary bypass is stable and bloodless exposure of the valve is obtained.

  10. Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass

    PubMed Central

    Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian

    2016-01-01

    This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. PMID:27694613

  11. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    PubMed

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Role of tricuspid valve repair for moderate tricuspid regurgitation during minimally invasive mitral valve surgery.

    PubMed

    Pfannmueller, Bettina; Verevkin, Alexander; Borger, Michael Andrew; Mende, Meinhard; Davierwala, Piroze; Garbade, Jens; Mohr, Friedrich Wilhelm; Misfeld, Martin

    2013-08-01

    The aim of this study was to investigate the impact of short- and mid-term survival of tricuspid valve (TV) repair versus conservative therapy in patients with preoperative moderate functional tricuspid regurgitation (TR) undergoing minimally invasive mitral valve (MV) surgery. Between January 2002 and December 2009, a total of 430 patients with pure mitral regurgitation and concomitant moderate TR underwent minimally invasive MV surgery for mitral regurgitation at the Leipzig Heart Center without (n = 336; group A) and with (n = 94; group B) TV surgery. Mean age was 66.7 ± 10.3 years, mean LVEF was 58.0 ± 13.8%, and 206 patients (47.9%) were male. Average logEuroSCORE was 12.4 ± 11.4%. Follow-up was on average 4.6 ± 2.4 years and 97% completed. Predischarge echocardiography showed no or mild TR in 51.1% of patients in group A versus 84.2% of patients in group B (p < 0.01). Overall 30-day mortality was 2.8% with no differences between both groups. Five-year survival was 82.9 ± 4.1% for patients with TV repair versus 85.0 ± 2.2% for patients without TV repair (p = 0.1) and it was 85.7 ± 3.3% in patients with moderate and more postoperative TR versus 90.1 ± 2.5% in patients with less than moderate postoperative TR (p = 0.08). Five-year freedom from TV-related reoperation was 98.8 ± 0.7% for patients in group A versus 98.9 ± 0.1% for patients in group B (p = 0.8). Patients undergoing MV surgery with moderate functional TR do not experience increased perioperative complication rates when a concomitant TV repair is performed. Our observations, combined with those of other groups, support current recommendations to perform concomitant TV repair in such patients, particularly if tricuspid annular dilation is present. Georg Thieme Verlag KG Stuttgart · New York.

  13. Mitral valve surgery using right anterolateral thoracotomy: is the aortic cannulation a safety procedure?

    PubMed

    Guedes, Marco Antonio Vieira; Pomerantzeff, Pablo Maria Alberto; Brandão, Carlos Manuel de Almeida; Vieira, Marcelo Luiz Campos; Grinberg, Max; Stolf, Noedir Antonio Groppo

    2010-01-01

    The right anterolateral thoracotomy is an alternative technique for surgical approach of mitral valve. In these cases, femoral-femoral bypass still has been used, rising occurrence of complications related to femoral cannulation. Describe the technique and results of mitral valve treatment by right anterolateral thoracotomy using aortic cannulation for cardiac pulmonary bypass (CPB). From 1983 e 2008, 100 consecutive female patients, with average age 35 ±13 years, 96 (96%) underwent mitral valve surgical treatment in the Heart Institute of São Paulo. A right anterolateral thoracotomy approach associated with aortic cannulation was used for CPB. Eighty (80%) patients had rheumatic disease and 84 (84%) patients presented functional class III or IV. Were performed 45 (45%) comissurotomies, 38 (38%) valve repairs, 7(7%) mitral valve replacements, seven (7%) recomissurotomies and three (3%) prosthesis replacement. Sparing surgery was performed in 90 (90%) patients. The average CPB and clamp time were 57 ± 27 min e 39 ± 19 min, respectively. There were no in-hospital death, reoperation due to bleeding and convertion to sternotomy. Introperative complications were related to heart harvest (5%), especially in reoperations (3%). The most important complications in postoperative period were related to pulmonary system (11%), followed by atrial fibrilation (10%) but without major systemic repercussions. The mean inhospital length of stay was 8 ± 3 days. Follow-up was 6.038 patients/month. Actuarial survival was 98.0 ± 1.9% and freedom from reoperation was 81.4 ± 7.8% in 180 months. The right anterolateral thoracotomy associated with aortic cannulation in mitral valve surgery is a simple technique, reproducible and safety.

  14. Minimally invasive aortic valve replacement – pros and cons of keyhole aortic surgery

    PubMed Central

    Szałański, Przemysław; Zembala, Michał; Filipiak, Krzysztof; Karolak, Wojciech; Wojarski, Jacek; Garbacz, Marcin; Kaczmarczyk, Aleksandra; Kwiecień, Anna; Zembala, Marian

    2015-01-01

    Over the last twenty years, minimally invasive aortic valve replacement (MIAVR) has evolved into a safe, well-tolerated and efficient surgical treatment option for aortic valve disease. It has been shown to reduce postoperative morbidity, providing faster recovery and rehabilitation, shorter hospital stay and better cosmetic results compared with conventional surgery. A variety of minimally invasive accesses have been developed and utilized to date. This concise review demonstrates and discusses surgical techniques used in contemporary approaches to MIAVR and presents the most important results of MIAVR procedures. PMID:26336491

  15. Serum uric acid level predicts adverse outcomes after myocardial revascularization or cardiac valve surgery.

    PubMed

    Lazzeroni, Davide; Bini, Matteo; Camaiora, Umberto; Castiglioni, Paolo; Moderato, Luca; Bosi, Davide; Geroldi, Simone; Ugolotti, Pietro T; Brambilla, Lorenzo; Brambilla, Valerio; Coruzzi, Paolo

    2018-01-01

    Background High levels of serum uric acid have been associated with adverse outcomes in cardiovascular diseases such as myocardial infarction and heart failure. The aim of the current study was to evaluate the prognostic role of serum uric acid levels in patients undergoing cardiac rehabilitation after myocardial revascularization and/or cardiac valve surgery. Design We performed an observational prospective cohort study. Methods The study included 1440 patients with available serum uric acid levels, prospectively followed for 50 ± 17 months. Mean age was 67 ± 11 years; 781 patients (54%) underwent myocardial revascularization, 474 (33%) cardiac valve surgery and 185 (13%) valve-plus-coronary artery by-pass graft surgery. The primary endpoints were overall and cardiovascular mortality while secondary end-points were combined major adverse cardiac and cerebrovascular events. Results Serum uric acid level mean values were 286 ± 95 µmol/l and elevated serum uric acid levels (≥360 µmol/l or 6 mg/dl) were found in 275 patients (19%). Overall mortality (hazard ratio = 2.1; 95% confidence interval: 1.5-3.0; p < 0.001), cardiovascular mortality (hazard ratio = 2.0; 95% confidence interval: 1.2-3.2; p = 0.004) and major adverse cardiac and cerebrovascular events rate (hazard ratio = 1.5; 95% confidence interval: 1.0-2.0; p = 0.019) were significantly higher in patients with elevated serum uric acid levels, even after adjustment for age, gender, arterial hypertension, diabetes, glomerular filtration rate, atrial fibrillation and medical therapy. Moreover, strong positive correlations between serum uric acid level and probability of overall mortality ( p < 0.001), cardiovascular mortality ( p < 0.001) and major adverse cardiac and cerebrovascular events ( p = 0.003) were found. Conclusions Serum uric acid levels predict mortality and adverse cardiovascular outcome in patients undergoing myocardial revascularization

  16. Effects of tranexamic acid on coagulation indexes of patients undergoing heart valve replacement surgery under cardiopulmonary bypass.

    PubMed

    Liu, Fei; Xu, Dong; Zhang, Kefeng; Zhang, Jian

    2016-12-01

    This study aims to explore the effects of tranexamic acid on the coagulation indexes of patients undergoing heart valve replacement surgery under the condition of cardiopulmonary bypass (CPB). One hundred patients who conformed to the inclusive criteria were selected and divided into a tranexamic acid group and a non-tranexamic acid group. They all underwent heart valve replacement surgery under CPB. Patients in the tranexamic acid group were intravenously injected with 1 g of tranexamic acid (100 mL) at the time point after anesthesia induction and before skin incision and at the time point after the neutralization of heparin. Patients in the non-tranexamic acid group were given 100 mL of normal saline at corresponding time points, respectively. Then the coagulation indexes of the two groups were analyzed. The activated blood clotting time (ACT) of the two groups was within normal scope before CPB, while four coagulation indexes including prothrombin time (PT), activated partial thromboplastin time (APTT), international normalized ratio (INR), and fibrinogen (FIB) had significant increases after surgery; the PT and INR of the tranexamic acid group had a remarkable decline after surgery. All the findings suggest that the application of tranexamic acid in heart valve replacement surgery under CPB can effectively reduce intraoperative and postoperative blood loss. © The Author(s) 2016.

  17. [Tricuspid valve regurgitation : Indications and operative techniques].

    PubMed

    Lange, R; Piazza, N; Günther, T

    2017-11-01

    Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.

  18. Aortic valve surgery - minimally invasive

    MedlinePlus

    ... There are two main types of new valves: Mechanical, made of man-made materials, such as titanium ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood ...

  19. Combined usage of inhaled and intravenous milrinone in pulmonary hypertension after heart valve surgery.

    PubMed

    Carev, Mladen; Bulat, Cristijan; Karanović, Nenad; Lojpur, Mihajlo; Jercić, Antonio; Nenadić, Denis; Marovih, Zlatko; Husedzinović, Ino; Letica, Dalibor

    2010-09-01

    Secondary pulmonary hypertension is a frequent condition after heart valve surgery. It may significantly complicate the perioperative management and increase patients' morbidity and mortality. The treatment has not been yet completely defined principally because of lack of the selectivity of drugs for the pulmonary vasculature. The usage of inhaled milrinone could be the possible therapeutic option. Inodilator milrinone is commonly used intravenously for patients with pulmonary hypertension and ventricular dysfunction in cardiac surgery. The decrease in systemic vascular resistance frequently necessitates concomitant use of norepinephrine. Pulmonary vasodilators might be more effective and also devoid of potentially dangerous systemic side effects if applied by inhalation, thus acting predominantly on pulmonary circulation. There are only few reports of inhaled milrinone usage in adult post cardiac surgical patients. We reported 2 patients with severe pulmonary hypertension after valve surgery. Because of desperate clinical situation, we decided to use the combination of inhaled and intravenous milrinone. Inhaled milrinone was delivered by means of pneumatic medication nebulizer dissolved with saline in final concentration of 0.5 mg/ml. The nebulizer was attached to the inspiratory limb of the ventilator circuit, just before the Y-piece. We obtained satisfactory reduction in mean pulmonary artery pressure in both patients, and they were successfully extubated and discharged. Although it is a very small sample of patients, we conclude that the combination of inhaled and intravenous milrinone could be an effective treatment of secondary pulmonary hypertension in high-risk cardiac valve surgery patient. The exact indications for inhaled milrinone usage, optimal concentrations for this route, and the beginning and duration of treatment are yet to be determined.

  20. Treatment of aortic stenosis with aortic valve bypass (apicoaortic conduit) surgery: an assessment using computational modeling.

    PubMed

    Balaras, Elias; Cha, K S; Griffith, Bartley P; Gammie, James S

    2009-03-01

    Aortic valve bypass surgery treats aortic valve stenosis with a valve-containing conduit that connects the left ventricular apex to the descending thoracic aorta. After aortic valve bypass, blood is ejected from the left ventricle via both the native stenotic aortic valve and the conduit. We performed computational modeling to determine the effects of aortic valve bypass on aortic and cerebral blood flow, as well as the effect of conduit size on relative blood flow through the conduit and the native valve. The interaction of blood flow with the vascular boundary was modeled using a hybrid Eurelian-Lagrangian formulation, where an unstructured Galerkin finite element method was coupled with an immersed boundary approach. Our model predicted native (stenotic) valve to conduit flow ratios of 45:55, 52:48, and 60:40 for conduits with diameters of 20, 16, and 10 mm, respectively. Mean gradients across the native aortic valve were calculated to be 12.5, 13.8, and 17.6 mm Hg, respectively. Post-aortic valve bypass cerebral blood flow was unchanged from preoperative aortic valve stenosis configurations and was constant across all conduit sizes. In all cases modeled, cerebral blood flow was completely supplied by blood ejected across the native aortic valve. An aortic valve bypass conduit as small as 10 mm results in excellent relief of left ventricular outflow tract obstruction in critical aortic valve stenosis. The presence of an aortic valve bypass conduit has no effect on cerebral blood flow. All blood flow to the brain occurs via antegrade flow across the native stenotic valve; this configuration may decrease the long-term risk of cerebral thromboembolism.

  1. Reversible preoperative renal dysfunction does not add to the risk of postoperative acute kidney injury after cardiac valve surgery

    PubMed Central

    Xu, Jia-Rui; Zhuang, Ya-Min; Liu, Lan; Shen, Bo; Wang, Yi-Mei; Luo, Zhe; Teng, Jie; Wang, Chun-Sheng; Ding, Xiao-Qiang

    2017-01-01

    Objective To evaluate the impact of the renal dysfunction (RD) type and change of postoperative cardiac function on the risk of developing acute kidney injury (AKI) in patients who underwent cardiac valve surgery. Method Reversible renal dysfunction (RRD) was defined as preoperative RD in patients who had not been initially diagnosed with chronic kidney disease (CKD). Cardiac function improvement (CFI) was defined as postoperative left ventricular ejection function – preoperative left ventricular ejection function (ΔEF) >0%, and cardiac function not improved (CFNI) as ΔEF ≤0%. Results Of the 4,805 (94%) cardiac valve surgery patients, 301 (6%) were RD cases. The AKI incidence in the RRD group (n=252) was significantly lower than in the CKD group (n=49) (36.5% vs 63.3%, P=0.018). The AKI and renal replacement therapy incidences in the CFI group (n=174) were significantly lower than in the CFNI group (n=127) (33.9% vs 50.4%, P=0.004; 6.3% vs 13.4%, P=0.037). After adjustment for age, gender, and other confounding factors, CKD and CKD + CFNI were identified as independent risk factors for AKI in all patients after cardiac valve surgery. Multivariate logistic regression analysis showed that the risk factors for postoperative AKI in preoperative RD patients were age, gender (male), hypertension, diabetes, chronic heart failure, cardiopulmonary bypass time (every 1 min added), and intraoperative hypotension, while CFI after surgery could reduce the risk. Conclusion For cardiac valve surgery patients, preoperative CKD was an independent risk factor for postoperative AKI, but RRD did not add to the risk. Improved postoperative cardiac function can significantly reduce the risk of postoperative AKI. PMID:29184415

  2. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review.

    PubMed

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm(2). Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9-54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier-Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair.

  3. Mitral Valve Stenosis after Open Repair Surgery for Non-rheumatic Mitral Valve Regurgitation: A Review

    PubMed Central

    Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R.; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael

    2016-01-01

    Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm2. Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9–54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier–Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair. PMID:27148540

  4. Epsilon-aminocaproic acid influence in postoperative [corrected] bleeding and hemotransfusion [corrected] in mitral valve surgery.

    PubMed

    Benfatti, Ricardo Ádala; Carli, Amanda Ferreira; Silva, Guilherme Viotto Rodrigues da; Dias, Amaury Edgardo Mont'serrat Ávila Souza; Goldiano, José Anderson; Pontes, José Carlos Dorsa Vieira

    2010-01-01

    The epsilon aminocaproic acid is an antifibrinolytic used in cardiovascular surgery to inhibit the fibrinolysis and to reduce the bleeding after CPB. [corrected] To analyze the influence of the using of epsilon aminocaproic acid in the bleeding and in red-cell transfusion requirement in the first twenty-four hours postoperative of mitral valve surgery. Prospective studying, forty-two patients, randomized and divided in two equal groups: group #1 control and group #2--epsilon aminocaproic acid. In Group II were infused five grams of EACA in the induction of anesthesia, after full heparinization, CPB perfusate after reversal of heparin and one hour after the surgery, totaling 25 grams. In group I, saline solution was infused only in those moments. Group #1 showed average bleeding volume of 633.57 ± 305,7 ml, and Group #2, an average of 308.81 ± 210.1 ml, with significant statistic difference (P = 0.0003). Average volume of red-cell transfusion requirement in Groups 1 and 2 was, respectively, 942.86 ± 345.79 ml and 214.29 ± 330.58 ml, with significant difference (P < 0.0001). The epsilon aminocaproic acid was able to reduce the bleeding volume and the red-cell transfusion requirement in the immediate postoperative of patients submitted to mitral valve surgery.

  5. Does moderate tricuspid regurgitation require attention during mitral valve surgery?

    PubMed

    Yeates, Alexander; Marwick, Thomas; Deva, Rajeev; Mundy, Julie; Wood, Annabelle; Griffin, Rayleene; Peters, Paul; Shah, Pallav

    2014-01-01

    This study aims to determine whether tricuspid regurgitation (TR) ≥ 2+ requires attention during mitral valve surgery. From April 1999 to 2009, 161 patients undergoing primary, isolated mitral valve procedures were assessed. Preoperative moderate TR (≥2+) was present in 56 of 161 patients and tricuspid valve repair (TVR: ring annuloplasty) was carried out on 22 of 56 patients with TR ≥ 2+. Baseline echocardiogram included TR severity (ASE criteria), TR velocity, estimated right atrial pressure, visual assessment of right ventricular failure and strain. Follow-up was 47 ± 33 months (96% complete); 91 of 161 patients overall (57%) and 44 of 45 patients with TR ≥ 2+ had follow-up echocardiogram. Patients with moderate TR had worse baseline functional class and operative risks, both worst in the non-TVR group. Overall mortality was 15% (n = 23), comprising 2.5% (4/161) 30-day mortality and 12% (9/157) late death. Poorer preoperative TR was associated with worse survival by univariate analysis (P = 0.046), after correction for right ventricular function and pulmonary artery pressure (P = 0.049), age and diabetes (P = 0.041). Despite lower risk of TR ≥ 2+ with TVR, 5-year survival was 42%, which was less than TR < 2+ and that of non-TVR group (90%, P = 0.003). Improvement in overall functional class (NYHA) was better in the non-TVR group (TVR: preoperative 2.1 ± 1.5; post-operative 1.2 ± 1.1 (P = 0.02) versus non-TVR: preoperative 1.8 ± 1.4, post-operative 1.2 ± 0.9 (P < 0.0001)). There was no difference in quality of life (QOL) indices (SF-36 questionnaire) at follow-up between patients with TR < 2+ and TR ≥ 2+ preoperatively, or across all levels of TR before or after surgical repair. Preoperative TR ≥ 2+, non-TVR group had more favourable functional class and mid-term survival with comparable QOL and echocardiographic parameters to the TVR group. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  6. Preoperative planning of left-sided valve surgery with 3D computed tomography reconstruction models: sternotomy or a minimally invasive approach?

    PubMed

    Heuts, Samuel; Maessen, Jos G; Sardari Nia, Peyman

    2016-05-01

    With the emergence of a new concept aimed at individualization of patient care, the focus will shift from whether a minimally invasive procedure is better than conventional treatment, to the question of which patients will benefit most from which technique? The superiority of minimally invasive valve surgery (MIVS) has not yet been proved. We believe that through better patient selection advantages of this technique can become more pronounced. In our current study, we evaluate the feasibility of 3D computed tomography (CT) imaging reconstruction in the preoperative planning of patients referred for MIVS. We retrospectively analysed all consecutive patients who were referred for minimally invasive mitral valve surgery (MIMVS) and minimally invasive aortic valve replacement (MIAVR) to a single surgeon in a tertiary referral centre for MIVS between March 2014 and 2015. Prospective preoperative planning was done for all patients and was based on evaluations by a multidisciplinary heart-team, an echocardiography, conventional CT images and 3D CT reconstruction models. A total of 39 patients were included in our study; 16 for mitral valve surgery (MVS) and 23 patients for aortic valve replacement (AVR). Eleven patients (69%) within the MVS group underwent MIMVS. Five patients (31%) underwent conventional MVS. Findings leading to exclusion for MIMVS were a tortuous or slender femoro-iliac tract, calcification of the aortic bifurcation, aortic elongation and pericardial calcifications. Furthermore, 2 patients had a change of operative strategy based on preoperative planning. Seventeen (74%) patients in the AVR group underwent MIAVR. Six patients (26%) underwent conventional AVR. Indications for conventional AVR instead of MIAVR were an elongated ascending aorta, ascending aortic calcification and ascending aortic dilatation. One patient (6%) in the MIAVR group was converted to a sternotomy due to excessive intraoperative bleeding. Two mortalities were reported during

  7. Risk model of prolonged intensive care unit stay in Chinese patients undergoing heart valve surgery.

    PubMed

    Wang, Chong; Zhang, Guan-xin; Zhang, Hao; Lu, Fang-lin; Li, Bai-ling; Xu, Ji-bin; Han, Lin; Xu, Zhi-yun

    2012-11-01

    The aim of this study was to develop a preoperative risk prediction model and an scorecard for prolonged intensive care unit length of stay (PrlICULOS) in adult patients undergoing heart valve surgery. This is a retrospective observational study of collected data on 3925 consecutive patients older than 18 years, who had undergone heart valve surgery between January 2000 and December 2010. Data were randomly split into a development dataset (n=2401) and a validation dataset (n=1524). A multivariate logistic regression analysis was undertaken using the development dataset to identify independent risk factors for PrlICULOS. Performance of the model was then assessed by observed and expected rates of PrlICULOS on the development and validation dataset. Model calibration and discriminatory ability were analysed by the Hosmer-Lemeshow goodness-of-fit statistic and the area under the receiver operating characteristic (ROC) curve, respectively. There were 491 patients that required PrlICULOS (12.5%). Preoperative independent predictors of PrlICULOS are shown with odds ratio as follows: (1) age, 1.4; (2) chronic obstructive pulmonary disease (COPD), 1.8; (3) atrial fibrillation, 1.4; (4) left bundle branch block, 2.7; (5) ejection fraction, 1.4; (6) left ventricle weight, 1.5; (7) New York Heart Association class III-IV, 1.8; (8) critical preoperative state, 2.0; (9) perivalvular leakage, 6.4; (10) tricuspid valve replacement, 3.8; (11) concurrent CABG, 2.8; and (12) concurrent other cardiac surgery, 1.8. The Hosmer-Lemeshow goodness-of-fit statistic was not statistically significant in both development and validation dataset (P=0.365 vs P=0.310). The ROC curve for the prediction of PrlICULOS in development and validation dataset was 0.717 and 0.700, respectively. We developed and validated a local risk prediction model for PrlICULOS after adult heart valve surgery. This model can be used to calculate patient-specific risk with an equivalent predicted risk at our centre in

  8. The challenge of valve-in-valve procedures in degenerated Mitroflow bioprostheses and the advantage of using the JenaValve transcatheter heart valve.

    PubMed

    Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik

    2014-12-01

    Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.

  9. Prosthetic valve endocarditis due to Propionibacterium acnes.

    PubMed

    van Valen, Richard; de Lind van Wijngaarden, Robert A F; Verkaik, Nelianne J; Mokhles, Mostafa M; Bogers, Ad J J C

    2016-07-01

    To study the characteristics of patients with Propionibacterium acnes prosthetic valve endocarditis (PVE) who required surgery. A single-centre retrospective cohort study was conducted during a 7-year period. Patients with definite infective P. acnes endocarditis, according to the modified Duke criteria, were included. An extended culture protocol was applied. Information on medical health status, surgery, antibiotic treatment and mortality was obtained. Thirteen patients fulfilled the criteria for P. acnes endocarditis (0.53% of 2466 patients with valve replacement in a 7-year period). All patients were male and had a previous valve replacement. The health status of patients was poor at diagnosis of P. acnes PVE. Most patients (11 of 13, 85%) were admitted with signs of heart failure due to a significant paravalvular leak; 2 of 13 (15%) patients presented with septic emboli. Twelve patients needed redo surgery, whereas one could be treated with antibiotic therapy only. The time between the index surgery and presentation with P. acnes PVE varied between 5 and 135 months (median 26.5 months). Replacement and reconstruction of the dysfunctional valve and affected anatomical structures was mainly performed with a mechanical valve (n = 5, 42%) or a (bio-) Bentall prosthesis (n = 6, 50%). Antibiotic therapy consisted of penicillin with or without rifampicin for 6 weeks after surgery. The mortality in this series was low (n = 1, 8%) and no recurrent endocarditis was found during a median follow-up of 38 months. Propionibacterium acnes PVE is a rare complication after valve surgery. Redo surgery is often required. Treatment of the dysfunctional prosthetic aortic valve most often consists of root replacement, in combination with antibiotic therapy. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Effect of comprehensive cardiac rehabilitation after heart valve surgery (CopenHeartVR): study protocol for a randomised clinical trial.

    PubMed

    Sibilitz, Kirstine Laerum; Berg, Selina Kikkenborg; Hansen, Tina Birgitte; Risom, Signe Stelling; Rasmussen, Trine Bernholdt; Hassager, Christian; Køber, Lars; Steinbrüchel, Daniel; Gluud, Christian; Winkel, Per; Thygesen, Lau Caspar; Hansen, Jane Lindschou; Schmid, Jean Paul; Conraads, Viviane; Brocki, Barbara Christina; Zwisler, Ann-Dorthe

    2013-04-22

    Heart valve diseases are common with an estimated prevalence of 2.5% in the Western world. The number is rising due to an ageing population. Once symptomatic, heart valve diseases are potentially lethal, and heavily influence daily living and quality of life. Surgical treatment, either valve replacement or repair, remains the treatment of choice. However, post surgery, the transition to daily living may become a physical, mental and social challenge. We hypothesise that a comprehensive cardiac rehabilitation programme can improve physical capacity and self-assessed mental health and reduce hospitalisation and healthcare costs after heart valve surgery. A randomised clinical trial, CopenHeartVR, aims to investigate whether cardiac rehabilitation in addition to usual care is superior to treatment as usual after heart valve surgery. The trial will randomly allocate 210 patients, 1:1 intervention to control group, using central randomisation, and blinded outcome assessment and statistical analyses. The intervention consists of 12 weeks of physical exercise, and a psycho-educational intervention comprising five consultations. Primary outcome is peak oxygen uptake (VO2 peak) measured by cardiopulmonary exercise testing with ventilatory gas analysis. Secondary outcome is self-assessed mental health measured by the standardised questionnaire Short Form 36. Also, long-term healthcare utilisation and mortality as well as biochemistry, echocardiography and cost-benefit will be assessed. A mixed-method design is used to evaluate qualitative and quantitative findings encompassing a survey-based study before the trial and a qualitative pre- and post-intervention study. The study is approved by the local regional Research Ethics Committee (H-1-2011-157), and the Danish Data Protection Agency (j.nr. 2007-58-0015). ClinicalTrials.gov (http://NCT01558765).

  11. Heart valve surgery - discharge

    MedlinePlus

    ... weeks, or when you can easily climb 2 flights of stairs or walk a half-mile (800 ... vomiting or diarrhea You become pregnant or are planning to become pregnant Alternative Names Aortic valve replacement - ...

  12. Results of Contemporary Valve Surgery in Patients with Carcinoid Heart Disease.

    PubMed

    Kuntze, Thomas; Owais, Tamer; Secknus, Maria-Anna; Kaemmerer, Daniel; Baum, Richard; Girdauskas, Evaldas

    2016-05-01

    six years postoperatively. At the latest follow up, 12 of the 17 survivors were in NYHA class I, and five in NYHA class II. The adverse cardiac event rate was 71%. Echocardiographically, 46% of patients (6/13) showed at least stationary or mild improvement in the right ventricular ejection fraction at follow up, with no evidence of paravalvular leak, infective endocarditis, or progressive other native valvular carcinoid affection. Postoperatively, the right atrial dimensions were preserved as normal in 23 patients (59%), mildly dilated in six (15%), moderately dilated in three (8%), and severely dilated in seven (18%). Valve-in-valve transcatheter aortic valve implantation was performed in two patients (12%) due to structural degeneration of the valve bioprosthesis and native valve disease progression. Despite advanced systemic disease, the surgical treatment of patients with carcinoid heart syndrome is associated with an acceptable perioperative risk and satisfactory mid-term survival. Those patients who survived valve surgery benefited from a significant improvement in their functional capacity. Percutaneous procedures may represent a useful tool to reduce the risk of late valvular reinterventions.

  13. [Papillary muscle rupture complicating acute myocardial infarction--treatment with mitral valve replacement and coronary bypass surgery in acute phase].

    PubMed

    Kyo, S; Miyamoto, N; Yokote, Y; Ueda, K; Takamoto, S; Omoto, R

    1996-06-01

    Complete rupture of a papillary muscle following acute myocardial infarction is a severe complication that is typically associated with acute left ventricular failure, pulmonary edema, and relentless clinical deterioration. The reported mortality rates without surgical intervention is almost 90%, therefore, prompt operation without prolonged attempts at medical stabilization is the key to decrease operative mortality. Although the complete coronary revascularization in conjunction with mitral valve replacement is advocated in the western medical academic society, there is only a few case of conjunct surgery has been reported in Japan. Three successful cases of conjunct surgery of mitral valve replacement and coronary complete revascularization in acute phase within one week from the onset of acute myocardial infarction (AMI) are described. There were one male and two female patients with an average age of 60-year-old (range 48-67), who developed cardiogenic shock and admitted to our hospital. The average interval between onset of AMI and the appearance of mitral regurgitation (MR) was 38 hours, and that of the appearance of MR and admission was 40 hours. Surgeries were performed within 26 hours (average 13 hours) after admission. The mitral valve was replaced with a mechanical valve (St. Jude Medical Valve) and a complete coronary revasculatization was done using saphenous vein graft. The average period of operation time and aortic cross clamping time were 6 hours 22 minutes and 109 minutes respectively. The average number of coronary grafting was 2.3 (range 1-3). Postoperative recovery from cardiogenic shock was uneventful in all three patients. The average periods of ICU stay and hospital stay were 5 days and 43 days respectively. All patients have regained their social activities with mean follow up period of 52 months. Since ischemic heart disease remains the leading cause of death in such patients, it is suggested that complete coronary revascularization

  14. Real-world echocardiography in patients referred for mitral valve surgery: the gap between guidelines and clinical practice.

    PubMed

    De Groot-de Laat, Lotte E; Ren, Ben; McGhie, Jackie; Oei, Frans B S; Raap, Goris Bol; Bogers, J J C; Geleijnse, Marcel L

    2014-11-01

    Mitral regurgitation (MR) is a common disorder for which mitral valve surgery is an established therapy. Although surgical indications are clearly defined for the management of valvular heart disease, a gap exists between current guidelines and their effective application. The study aim was to provide an insight into the diagnostic information provided for cardiac surgeons before performing mitral valve surgery. The source documents and echocardiographic studies of 100 patients, referred by nine hospitals, were screened for arguments for MR severity justifying referral for surgery. Details of the documented MR mechanism, mitral annulus (MA) size, tricuspid regurgitation (TR) severity and annulus size were also noted. According to the referring physician, MR was severe in 83% and moderate-to-severe in 17%. In the great majority of patients (98%) the MR mechanism was mentioned, although specific information on the prolapsing scallops was available in only 17% of cases. The recommended primary determinants of MR severity, vena contracta and proximal isovelocity surface area (PISA) were measured in only 22% and 31% of patients, respectively. In 94% of patients with available PISA information this was described only qualitatively. Correct image expansion using the zoom mode was performed in only 25% of these patients, and a correct adaptation of the Nyquist limit in only 6%. Tricuspid annulus measurements guiding the need for concomitant tricuspid valvuloplasty in patients with less than severe TR were reported in only 6% of patients. These data demonstrate a clear and important gap between current guidelines and real-world practice with regards to the echocardiographic diagnostic information provided to the surgeon before performing mitral valve surgery.

  15. Effect of comprehensive cardiac rehabilitation after heart valve surgery (CopenHeartVR): study protocol for a randomised clinical trial

    PubMed Central

    2013-01-01

    Background Heart valve diseases are common with an estimated prevalence of 2.5% in the Western world. The number is rising due to an ageing population. Once symptomatic, heart valve diseases are potentially lethal, and heavily influence daily living and quality of life. Surgical treatment, either valve replacement or repair, remains the treatment of choice. However, post surgery, the transition to daily living may become a physical, mental and social challenge. We hypothesise that a comprehensive cardiac rehabilitation programme can improve physical capacity and self-assessed mental health and reduce hospitalisation and healthcare costs after heart valve surgery. Methods A randomised clinical trial, CopenHeartVR, aims to investigate whether cardiac rehabilitation in addition to usual care is superior to treatment as usual after heart valve surgery. The trial will randomly allocate 210 patients, 1:1 intervention to control group, using central randomisation, and blinded outcome assessment and statistical analyses. The intervention consists of 12 weeks of physical exercise, and a psycho-educational intervention comprising five consultations. Primary outcome is peak oxygen uptake (VO2 peak) measured by cardiopulmonary exercise testing with ventilatory gas analysis. Secondary outcome is self-assessed mental health measured by the standardised questionnaire Short Form 36. Also, long-term healthcare utilisation and mortality as well as biochemistry, echocardiography and cost-benefit will be assessed. A mixed-method design is used to evaluate qualitative and quantitative findings encompassing a survey-based study before the trial and a qualitative pre- and post-intervention study. Discussion The study is approved by the local regional Research Ethics Committee (H-1-2011-157), and the Danish Data Protection Agency (j.nr. 2007-58-0015). Trial registration ClinicalTrials.gov (http://NCT01558765). PMID:23782510

  16. Tricuspid annuloplasty versus a conservative approach in patients with functional tricuspid regurgitation undergoing left-sided heart valve surgery: A study-level meta-analysis.

    PubMed

    Pagnesi, Matteo; Montalto, Claudio; Mangieri, Antonio; Agricola, Eustachio; Puri, Rishi; Chiarito, Mauro; Ancona, Marco B; Regazzoli, Damiano; Testa, Luca; De Bonis, Michele; Moat, Neil E; Rodés-Cabau, Josep; Colombo, Antonio; Latib, Azeem

    2017-08-01

    Tricuspid valve (TV) repair at the time of left-sided valve surgery is indicated in patients with either severe functional tricuspid regurgitation (TR) or mild-to-moderate TR with coexistent tricuspid annular dilation or right heart failure. We assessed the benefits of a concomitant TV repair strategy during left-sided surgical valve interventions, focusing on mortality and echocardiographic TR-related outcomes. A meta-analysis was performed of studies reporting outcomes of patients who underwent left-sided (mitral and/or aortic) valve surgery with or without concomitant TV repair. Primary endpoints were all-cause and cardiac-related mortality; secondary endpoints were the presence of more-than-moderate TR, TR progression, and TR severity grade. All endpoints were evaluated at the longest available follow-up. Fifteen studies were included for a total of 2840 patients. TV repair at the time of left-sided valve surgery was associated with a significantly lower risk of cardiac-related mortality (odds ratio [OR] 0.38; 95% confidence interval [CI]: 0.25-0.58; p<0.001), with a trend towards a lower risk of all-cause mortality (OR 0.57; 95% CI: 0.32-1.05; p=0.07) at a mean weighted follow-up of 6years. The presence of more-than-moderate TR (OR 0.19; 95% CI: 0.12-0.30; p<0.001), TR progression (OR 0.03; 95% CI: 0.01-0.05; p<0.001), and TR grade (standardized mean difference -1.11; 95% CI: -1.57 to -0.65; p<0.001) were significantly lower in the TV repair group at a mean weighted follow-up of 4.7years. A concomitant TV repair strategy during left-sided valve surgery is associated with a reduction in cardiac-related mortality and improved echocardiographic TR outcomes at follow-up. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  17. The Results of the Use of Ahmed Valve in Refractory Glaucoma Surgery

    PubMed Central

    Bikbov, Mukharram Mukhtaramovich

    2015-01-01

    ABSTRACT The treatment of refractory glaucoma (RG) is challenging. The commonly adopted strategy in RG treatment is a glaucoma drainage device (GDD) implantation, which despite its radical nature may not always provide the desired intraocular pressure (IOP) levels for a long term. This review is based on the scientific literature on Ahmed glaucoma valve (AGV) implantation for refractory glaucoma. The technique of AGV implantation is described and data for both the types, FP7 and FP8 performance are presented. The outcome with adjunct antimetabolite and anti-VEGF drugs are also highlighted. An insight is given about experimental and histological examinations of the filtering bleb encapsulation. The article also describes various complications and measures to prevent them. How to cite this article: Bikbov MM, Khusnitdinov II. The Results of the Use of Ahmed Valve in Refractory Glaucoma Surgery. J Curr Glaucoma Pract 2015;9(3):86-91. PMID:26997843

  18. Aortic valve repair leads to a low incidence of valve-related complications.

    PubMed

    Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim

    2010-01-01

    Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  19. Minimally invasive mitral valve surgery expands the surgical options for high-risks patients.

    PubMed

    Petracek, Michael R; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Balaguer, Jorge M; Byrne, John G

    2011-10-01

    A simplified minimally invasive mitral valve surgery (MIMVS) approach avoiding cross-clamping and cardioplegic myocardial arrest using a small (5 cm) right antero-lateral incision was developed. We hypothesized that, in high-risk patients and in patients with prior sternotomy, this approach would yield superior results compared to those predicted by the Society of Thoracic Surgeons (STS) algorithm for standard median sternotomy mitral valve surgery. Five hundred and four consecutive patients (249 males/255 females), median age 65 years (range 20-92 years) underwent MIMVS between 1/06 and 8/09. Median preoperative New York Heart Association function class was 3 (range 1-4). Eighty-two (16%) patients had an ejection fraction ≤35%. Forty-seven (9%) had a STS predicted mortality ≥10%. Under cold fibrillatory arrest (median temperature 28°C) without aortic cross-clamp, mitral valve repair (224/504, 44%) or replacement (280/504, 56%) was performed. Thirty-day mortality for the entire cohort was 2.2% (11/504). In patients with a STS predicted mortality ≥ 10% (range 10%-67%), the observed 30-day mortality was 4% (2/47), lower than the mean STS predicted mortality of 20%. Morbidity in this high-risk group was equally low: 1 of 47 (2%) patients underwent reexploration for bleeding, 1 of 47 (2%) patients suffered a permanent neurologic deficit, none had wound infection. The median length of stay was 8 days (range 1-68 days). This study demonstrates that MIMVS without aortic cross-clamp is reproducible with low mortality and morbidity rates. This approach expands the surgical options for high-risk patients and yields to superior results than the conventional median sternotomy approach.

  20. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    PubMed

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  1. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    PubMed

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Prosthetic Mitral Valve Leaflet Escape

    PubMed Central

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  3. Aortic valve replacement for papillary fibroelastoma.

    PubMed

    Arikan, Ali Ahmet; Omay, Oğuz; Aydın, Fatih; Kanko, Muhip; Gür, Sibel; Derviş, Emir; Yılmaz, Cansu Eda; Müezzinoğlu, Bahar

    2017-06-01

    Surgery is indicated for symptomatic patients with papillary fibroelastomas (PFE) on the aortic valve. The valve is commonly spared during tumor excision. Rarely, aortic valve replacement (AVR) is needed. We present a case requiring AVR for an aortic valve PFE and review the literature to determine the risk factors for failure of aortic valve-sparing techniques in patients with PFE. © 2017 Wiley Periodicals, Inc.

  4. Will Catheter Interventions Replace Surgery for Valve Abnormalities?

    PubMed Central

    O’Byrne, Michael L; Gillespie, Matthew J

    2015-01-01

    Purpose of Review Catheter-based valve technologies have evolved rapidly over the last decade. Transcatheter aortic valve replacement (TAVR) has become a routine procedure in high-risk adult patients with calcific aortic stenosis. In patients with congenital heart disease (CHD), transcatheter pulmonary valve replacement represents a transformative technology for right ventricular outflow tract dysfunction with the potential to expand to other indications. This review aims to summarize 1) the current state of the art for transcatheter valve replacement (TVR) in CHD, 2) the expanding indications for TVR, and 3) the technological obstacles to optimizing TVR. Recent findings Multiple case series have demonstrated that TVR with the Melody transcatheter pulmonary valve in properly selected patients is safe, effective, and durable in short-term follow-up. The Sapien transcatheter heart valve represents an alternative device with similar safety and efficacy in limited studies. Innovative use of current valves has demonstrated the flexibility of TVR, while highlighting the need for devices to address the broad range of post-operative anatomies either with a single device or strategies to prepare the outflow tract for subsequent device deployment. Summary The potential of TVR has not been fully realized, but holds promise in treatment of CHD. PMID:24281347

  5. Minimally Invasive Mitral Valve Procedures: The Current State

    PubMed Central

    Ritwick, Bhuyan; Chaudhuri, Krishanu; Crouch, Gareth; Edwards, James R. M.; Worthington, Michael; Stuklis, Robert G.

    2013-01-01

    Since its early days, cardiac surgery has typically involved large incisions with complete access to the heart and the great vessels. After the popularization of the minimally invasive techniques in general surgery, cardiac surgeons began to experiment with minimal access techniques in the early 1990s. Although the goals of minimally invasive cardiac surgery (MICS) are fairly well established as decreased pain, shorter hospital stay, accelerated recuperation, improved cosmesis, and cost effectiveness, a strict definition of minimally invasive cardiac surgery has been more elusive. Minimally invasive cardiac surgery started with mitral valve procedures and then gradually expanded towards other valve procedures, coronary artery bypass grafting, and various types of simple congenital heart procedures. In this paper, the authors attempt to focus on the evolution, techniques, results, and the future perspective of minimally invasive mitral valve surgery (MIMVS). PMID:24382998

  6. Mitral valve surgery in emergency for severe acute regurgitation: analysis of postoperative results from a multicentre study.

    PubMed

    Lorusso, Roberto; Gelsomino, Sandro; De Cicco, Giuseppe; Beghi, Cesare; Russo, Claudio; De Bonis, Michele; Colli, Andrea; Sala, Andrea

    2008-04-01

    To evaluate postoperative outcome of emergency surgery for acute severe mitral regurgitation (ASMR) from a multicentre experience. In six centres, 279 patients (mean age 62+/-14 years, 62% female) undergoing emergency surgery for ASMR from December 1986 to March 2007 were analysed and followed up. Aetiology included acute myocardial infarction (AMI) in 126 patients (group 1, 45%), degenerative mitral valve disease in 74 (group 2, 26%), and acute endocarditis (AE) in 79 (group 3, 28%). Preoperatively, all patients were in haemodynamic instability, with 185 patients in cardiogenic shock (66%), 184 (66%) intubated, and 61 (22%) on IABP, respectively. Valve repair was performed in 76 (27%), whereas 203 (73%) underwent valve replacement. Median follow-up (98% complete) was 70.8 months (inter-quartile range 59.8-86.66 months). Overall 30-day mortality was 22.5% (63/279). Early death was significantly lower in group 2 (p<0.001 and p=0.005 vs group 1 and 3, respectively) whereas no difference was detected between group 1 and 3. At logistic regression analysis AMI, AE, shock, left ventricular dysfunction, and coronary artery disease were predictors of early death. Overall 15-year survival was 67+/-10%. Survival was lower in group 1 (39+/-11%) than in group 2 (75+/-9%) and group 3 (77+/-10%). Cox regression found AMI, and associated coronary artery disease to be predictors of late death. Overall 15-year actuarial and actual freedom from cardiac-related events were 44+/-9% and 28+/-10%, respectively, with the worst outcome in the presence of AE. Associated coronary artery disease, AE, AMI, preoperative atrial fibrillation, and chronic renal failure were independent predictors of cardiac-related events. Emergency surgery for ASMR remains a surgical challenge for high incidence of early and late cardiac-related events, particularly in patients with associated coronary artery disease and acute endocarditis. Apparently, type of mitral valve surgical approaches (repair or

  7. MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.

    PubMed

    Kistan, D; Booysen, M; Alexander, G; Madiba, T E

    2017-06-01

    Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients

  8. Surgery for prosthetic valve endocarditis: associations between morbidity, mortality and costs.

    PubMed

    Grubitzsch, Herko; Christ, Torsten; Melzer, Christoph; Kastrup, Marc; Treskatsch, Sascha; Konertz, Wolfgang

    2016-06-01

    Surgery for prosthetic valve endocarditis (PVE) is associated with significant morbidity and mortality as well as with increased resource utilization and costs. For risk and cost reduction, an understanding of contributing factors and interrelations is essential. Out of 1080 heart valve procedures performed between January 2010 and December 2012, 41 patients underwent surgery for PVE. Complete economic data were available for 30 of them (study cohort). The patients' mean age was 64 ± 12 years (range 37-79 years), and 73% were men. The clinical course was reviewed and morbidity, mortality and costs as well as associations between them were analysed. The cost matrix for each individual patient was obtained from the Institute for the Hospital Remuneration System (InEK GmbH, Germany). The median follow-up was 2.6 years [interquartile range (IQR) 3.7 years; 100% complete]. Preoperative status was critical (EuroSCORE II >20%) in 43% of patients. Staphylococci were the most common infecting micro-organisms (27%). The operative mortality rate (≤30 days) was 17%. At 1 year, the overall survival rate was 71 ± 9%. At least one disease- or surgery-related complication affected 21 patients (early morbidity 70%), >1 complication affected 12 patients (40%). There was neither a recurrence of endocarditis, nor was a reoperation required. The mean total hospital costs were 42.6 ± 37.4 Thousand Euro (T€), median 25.7 T€, IQR 28.4 T€ and >100 T€ in 10% of cases. Intensive care unit/intermediate care (ICU/IMC) and operation accounted for 40.4 ± 18.6 and 25.7 ± 12.1% of costs, respectively. There was a significant correlation (Pearson's sample correlation coefficient) between total costs and duration of hospital stay (r = 0.83, P < 0.001) and between ICU/IMC costs and duration of ICU/IMC stay (r = 0.97, P < 0.001). The median daily hospital costs were 1.8 T€/day, but >2.4 T€/day in 25% of patients (upper quartile). The following pattern of associations was identified

  9. Surgery for prosthetic valve endocarditis: associations between morbidity, mortality and costs†

    PubMed Central

    Grubitzsch, Herko; Christ, Torsten; Melzer, Christoph; Kastrup, Marc; Treskatsch, Sascha; Konertz, Wolfgang

    2016-01-01

    OBJECTIVES Surgery for prosthetic valve endocarditis (PVE) is associated with significant morbidity and mortality as well as with increased resource utilization and costs. For risk and cost reduction, an understanding of contributing factors and interrelations is essential. METHODS Out of 1080 heart valve procedures performed between January 2010 and December 2012, 41 patients underwent surgery for PVE. Complete economic data were available for 30 of them (study cohort). The patients' mean age was 64 ± 12 years (range 37–79 years), and 73% were men. The clinical course was reviewed and morbidity, mortality and costs as well as associations between them were analysed. The cost matrix for each individual patient was obtained from the Institute for the Hospital Remuneration System (InEK GmbH, Germany). The median follow-up was 2.6 years [interquartile range (IQR) 3.7 years; 100% complete]. RESULTS Preoperative status was critical (EuroSCORE II >20%) in 43% of patients. Staphylococci were the most common infecting micro-organisms (27%). The operative mortality rate (≤30 days) was 17%. At 1 year, the overall survival rate was 71 ± 9%. At least one disease- or surgery-related complication affected 21 patients (early morbidity 70%), >1 complication affected 12 patients (40%). There was neither a recurrence of endocarditis, nor was a reoperation required. The mean total hospital costs were 42.6 ± 37.4 Thousand Euro (T€), median 25.7 T€, IQR 28.4 T€ and >100 T€ in 10% of cases. Intensive care unit/intermediate care (ICU/IMC) and operation accounted for 40.4 ± 18.6 and 25.7 ± 12.1% of costs, respectively. There was a significant correlation (Pearson's sample correlation coefficient) between total costs and duration of hospital stay (r = 0.83, P < 0.001) and between ICU/IMC costs and duration of ICU/IMC stay (r = 0.97, P < 0.001). The median daily hospital costs were 1.8 T€/day, but >2.4 T€/day in 25% of patients (upper quartile). The following pattern of

  10. Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.

    PubMed

    Wolf, Alvit; Hod, Yair; Buckman, Gila; Stein, Nili; Geyer, Orna

    2016-04-01

    To compare the efficacy of an autoscleral free-flap graft versus an autoscleral rotational flap graft in Ahmed glaucoma valve (AGV) surgery. Medical records (2005 to 2012) of 51 consecutive patients (51 eyes) who underwent AGV surgery with the use of either an autoscleral free-flap graft or an autoscleral rotational flap graft to cover the external tube at the limbus were retrieved for review. The main outcome measure was the incidence of tube exposure associated with each surgical approach. Twenty-seven consecutive patients (27 eyes) received a free-flap graft and 24 consecutive patients (24 eyes) received a rotational flap graft. The mean follow-up time was 55.6 ± 18.3 months for the former and 24.2± 5 .0 months for the latter (P<0.0001). Two patients in the free-flap group (8.9%) developed tube exposure at 24 and 55 months postoperatively compared with none of the patients in the rotational flap group. Graft thinning without evidence of conjunctival erosion was observed in 15 patients (55%) in the free-flap group and in 7 patients (29.1%) in the rotational flap group. The use of an autoscleral rotational flap graft is an efficacious technique for primary tube patch grafting in routine AGV surgery, and yielded better results than an autoscleral free-flap graft. Its main advantages over donor graft material are availability and lower cost.

  11. Concomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.

    PubMed

    Aydin, Unal; Gul, Mehmet; Aslan, Serkan; Akkaya, Emre; Yildirim, Aydin

    2015-04-28

    Transcatheter valve implantation is a novel interventional technique, which was developed as an  alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.

  12. Type of Valvular Heart Disease Requiring Surgery in the 21st Century: Mortality and Length-of-Stay Related to Surgery

    PubMed Central

    Boudoulas, Konstantinos Dean; Ravi, Yazhini; Garcia, Daniel; Saini, Uksha; Sofowora, Gbemiga G.; Gumina, Richard J.; Sai-Sudhakar, Chittoor B.

    2013-01-01

    Aim: While the incidence of rheumatic heart disease has declined dramatically over the last half-century, the number of valve surgeries has not changed. This study was undertaken to define the most common type of valvular heart disease requiring surgery today, and determine in-hospital surgical mortality and length-of-stay (LOS) for isolated aortic or mitral valve surgery in a United States tertiary-care hospital. Methods: Patients with valve surgery between January 2002 to June 2008 at The Ohio State University Medical Center were studied. Patients only with isolated aortic or mitral valve surgery were analyzed. Results: From 915 patients undergoing at least aortic or mitral valve surgery, the majority had concomitant cardiac proce-dures mostly coronary artery bypass grafting (CABG); only 340 patients had isolated aortic (n=204) or mitral (n=136) valve surgery. In-hospital surgical mortality for mitral regurgitation (n=119), aortic stenosis (n=151), aortic insufficiency (n=53) and mitral stenosis (n=17) was 2.5% (replacement 3.4%; repair 1.6%), 3.9%, 5.6% and 5.8%, respectively (p=NS). Median LOS for aortic insufficiency, aortic stenosis, mitral regurgitation, and mitral stenosis was 7, 8, 9 (replacement 11.5; repair 7) and 11 days, respectively (p<0.05 for group). In-hospital surgical mortality for single valve surgery plus CABG was 10.2% (p<0.005 compared to single valve surgery). Conclusions: Aortic stenosis and mitral regurgitation are the most common valvular lesions requiring surgery today. Surgery for isolated aortic or mitral valve disease has low in-hospital mortality with modest LOS. Concomitant CABG with valve surgery increases mortality substantially. Hospital analysis is needed to monitor quality and stimulate improvement among Institutions. PMID:24339838

  13. Valve-sparing options in tetralogy of Fallot surgery.

    PubMed

    Bacha, Emile

    2012-01-01

    Given late outcomes of patients with tetralogy of Fallot repaired in the 1970s and 1980s, as well as a better understanding of the late deleterious effects of pulmonary regurgitation, there is a tendency toward preservation of the pulmonary valve function during primary repair of tetralogy of Fallot. The bar keeps moving downward, to include smaller and more dysmorphic pulmonary valves. This article reviews some useful indications and techniques for valve-sparing options, including intraoperative balloon dilation and cusp reconstruction using a patch. Just like other valve repair techniques, no one technique can be applied uniformly, and surgeons must master a wide armamentarium of techniques. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Surgical ablation of atrial fibrillation in patients with a giant left atrium undergoing mitral valve surgery.

    PubMed

    Kim, Ho Jin; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2016-08-01

    As the efficacy of surgical ablation for atrial fibrillation (AF) is reported to be suboptimal for patients with a giant left atrium (LA), its routine use on this population has remained controversial. We sought to evaluate the clinical outcomes of patients with a giant LA undergoing mitral valve (MV) surgery with/without the maze procedure. We identified 759 patients with a giant LA (>60 mm) and AF undergoing MV surgery from 1999 through 2012. Of these, 400 underwent MV surgery with the maze procedure (maze group), and the remainder (n=359) underwent MV surgery only (no-maze group). To reduce the impact of selection bias, propensity score analyses were performed based on 25 baseline covariates. Early death occurred in five (1.3%) and nine (2.5%) patients in the maze and the no-maze group, respectively (p=0.28). Freedom from AF at 5 years was 68.9% in the maze group and 9.6% in the no-maze group (p<0.001). After adjustment, the maze group showed a significantly lower risk of death (HR, 0.65; 95% CI 0.44 to 0.98; p=0.038), thromboembolic events (HR, 0.23; 95% CI 0.09 to 0.58; p=0.002) and composite adverse outcomes (death, congestive heart failure and valve-related complications; HR, 0.55; 95% CI 0.42 to 0.71; p<0.001) than the no-maze group. In subgroup analyses, MV surgery with the maze procedure resulted in higher survival and event-free survival in most risk subgroups than without the maze procedure. The concomitant maze procedure improved postoperative rhythm status, clinical outcomes and cardiac functions in patients with a giant LA undergoing MV surgery. This study indicates that the patients with a giant LA undergoing MV surgery may benefit from an addition of the maze procedure. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Inflammatory response and postoperative kidney failure in patients with diabetes type 2 or impaired glucose tolerance undergoing heart valve surgery.

    PubMed

    Zakrzewski, Dariusz; Janas, Jadwiga; Heretyk, Hanna; Stepińska, Janina

    2010-05-01

    Diabetes type 2 (DM) or impaired glucose tolerance (IGT) are linked with a 3-fold increased risk of renal failure after heart valve surgery. The increase of proinflammatory cytokines is detected in patients with DM or IGT, moreover cardiac surgery promotes the proinflammatory response, which may be responsible for the development of postoperative kidney failure. To assess the impact of perioperative pro- and antiinflammatory reaction after heart valve surgery and other clinical parameters on the risk of postoperative acute kidney injury in patients with DM or IGT. Thirty patients with DM or IGT, without fibrate or statin treatment, with a mean LDL-cholesterol below 129 mg/dL, ejection fraction > 45%, in NYHA class II and III, referred for surgery due to acquired heart valve disease entered the study. Patients with acute or chronic inflammatory conditions, coronary artery disease or creatinine clearance below 50 mL/min were excluded. Serum creatinine, glycosylated hemoglobin, LDL-cholesterol and interleukin-10 as well as TNF-alpha were assessed before surgery. Interleukin-10 and TNF-alpha were also measured 4 hours after weaning from cardiopulmonary bypass. Moreover, serum creatinine and hemoglobin were measured 18 +/- 2 hours after surgery. The relationship between postoperative creatinine clearance, its postoperative change and other parameters was assessed. These parameters included: age, weight and body mass index, pre- and postoperative serum level of TNF-alpha and interleukin-10, preoperative concentration of LDL-cholesterol and glycosylated hemoglobin, duration of cardiopulmonary bypass and postoperative hemoglobin. The significant postoperative decrease of creatinine clearance was noted in the study group. Eight (27%) patients developed postoperative kidney failure, of them 2 (6.5%) patients required hemodialysis. The level of TNF-alpha and interleukin-10 increased significantly postoperatively. A significant correlation between duration of cardiopulmonary

  16. Aortic valve bypass surgery in severe aortic valve stenosis: Insights from cardiac and brain magnetic resonance imaging.

    PubMed

    Mantini, Cesare; Caulo, Massimo; Marinelli, Daniele; Chiacchiaretta, Piero; Tartaro, Armando; Cotroneo, Antonio Raffaele; Di Giammarco, Gabriele

    2018-04-13

    To investigate and describe the distribution of aortic and cerebral blood flow (CBF) in patients with severe valvular aortic stenosis (AS) before and after aortic valve bypass (AVB) surgery. We enrolled 10 consecutive patients who underwent AVB surgery for severe AS. Cardiovascular magnetic resonance imaging (CMR) and brain magnetic resonance imaging were performed as baseline before surgery and twice after surgery. Quantitative flow measurements were obtained using 1.5-T magnetic resonance imaging (MRI) scanner phase-contrast images of the ascending aorta, descending thoracic aorta (3 cm proximally and distally from the conduit-to-aorta anastomosis), and ventricular outflow portion of the conduit. The evaluation of CBF was performed using 3.0-T MRI scanner arterial spin labeling (ASL) through sequences acquired at the gray matter, dorsal default-mode network, and sensorimotor levels. Conduit flow, expressed as the percentage of total antegrade flow through the conduit, was 63.5 ± 8% and 67.8 ± 7% on early and mid-term postoperative CMR, respectively (P < .05). Retrograde perfusion from the level of the conduit insertion in the descending thoracic aorta toward the aortic arch accounted for 6.9% of total cardiac output and 11% of total conduit flow. We did not observe any significant reduction in left ventricular stroke volume at postoperative evaluation compared with preoperative evaluation (P = .435). No differences were observed between preoperative and postoperative CBF at the gray matter, dorsal default-mode network, and sensorimotor levels (P = .394). After AVB surgery in patients with severe AS, cardiac output is split between the native left ventricular outflow tract and the apico-aortic bypass, with two-thirds of the total antegrade flow passing through the latter and one-third passing through the former. In our experience, CBF assessment confirms that the flow redistribution does not jeopardize cerebral blood supply. Copyright © 2018 The

  17. Echocardiography for Intraoperative Decision Making in Mitral Valve Surgery-A Pilot Simulation-Based Training Module.

    PubMed

    Morais, Rex Joseph; Ashokka, Balakrishnan; Paranjothy, Suresh; Siau, Chiang; Ti, Lian Kah

    2017-10-01

    Echocardiographic assessment of the repaired or replaced mitral valve intraoperatively involves making a high-impact joint decision with the surgeon, in a time-sensitive manner, in a dynamic clinical situation. These decisions have to take into account the degree of imperfection if any, the likelihood of obtaining a better result, the underlying condition of the patient, and the impact of a longer cardiopulmonary bypass period if the decision is made to reintervene. Traditional echocardiography teaching is limited in its ability to provide this training. The authors report the development and implementation of a training module simulating the dynamic clinical environment of a mitral valve surgery in progress and the critical echo-based intraoperative decision making involved in the assessment of the acceptability of the surgical result. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Complications and 2-year valve survival following Ahmed valve implantation during the first 2 years of life.

    PubMed

    Almobarak, F; Al-Mobarak, F; Khan, A O

    2009-06-01

    To report complications and 2-year valve survival following Ahmed valve implantation during the first 2 years of life. Retrospective institutional case series. Forty-two eyes of 36 patients with Ahmed valve implantation (without prior drainage device surgery) during the first 2 years of life and 2 years' postsurgical follow-up were identified. Most eyes had primary congenital glaucoma (28/42, 66.7%), aphakic glaucoma (5/42, 11.9%) or Peters anomaly (5/42, 11.9%). All but three eyes had prior ocular surgery. Surgery was at a mean age of 11.83 months (m) (SD 5.63). The most common significant postoperative complications were tube malpositioning requiring intervention (11/42, 26.2%), endophthalmitis (3/42, 7.1%; one with tube exposure) and retinal detachment (3/42, 7.1%). Thirty-six eyes (85.8%) required resumption of antiglaucoma medications to maintain intraocular pressure (IOP) < or =22 mm Hg a mean of 7.2 m (SD 6.8) postoperatively. Cumulative probabilities of valve survival (IOP< or =22 mm Hg with or without medication) by Kaplan-Meier analysis were 73.8% and 63.3% at 12 months and 24 months, respectively. Postoperative tube malpositioning that required surgical revision was common in this age group. Infectious endophthalmitis and retinal detachment are known potential complications following any incisional surgery for advanced buphthalmos; however, tube exposure is a unique potential problem following aqueous shunt implantation that can lead to intraocular infection. Cumulative valve survival 2 years following implantation was 63.3%.

  19. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    PubMed

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Minimally invasive aortic valve surgery. A safe and useful technique beyond the cosmetic benefits.

    PubMed

    Paredes, Federico A; Cánovas, Sergio J; Gil, Oscar; García-Fuster, Rafael; Hornero, Fernando; Vázquez, Alejandro; Martín, Elio; Mena, Armando; Martínez-León, Juan

    2013-09-01

    The aim of this study was to compare the in-hospital clinical outcomes of minimally invasive, isolated aortic valve replacement vs median sternotomy. Between 2005 and 2012, 615 patients underwent aortic valve replacement at a single institution, 532 by a median sternotomy (E group) and 83 by a J-shaped ministernotomy (M group). No significant differences were found between the E and M groups in terms of age (69.27 [9.31] years vs 69.40 [10.24] years, respectively), logistic EuroSCORE (6.27 [2.91] vs 5.64 [2.17], respectively), size of implanted valve prosthesis (21.94 [2.04] mm vs 21.79 [2.01] mm, respectively), or the incidence of diabetes, hypercholesterolemia, high blood pressure, or chronic obstructive pulmonary disease. Mean cardiopulmonary bypass time was 102.90 (41.68) min for the E group vs 81.37 (25.41) min for the M group (P<.001). Mean cross-clamp time was 77.31 (29.20) min vs 63.45 (17.71) min for the S and M groups, respectively (P<.001). Mortality in the E group was 4.88% (26). There were no deaths in the M group (P<.05). The E group was associated with longer intensive care unit and hospital stays: 4.17 (5.23) days vs 3.22 (2.01) days (P=.045) and 9.58 (7.66) days vs 7.27 (3.83) days (P<.001), respectively. E group patients had more postoperative respiratory complications (42 [8%] vs 1 [1.2%]; P<.05). There were no differences when postoperative hemodynamic, neurologic, and renal complications, systemic infection, and wound infection were analyzed. In terms of morbidity, mortality, and operative times, outcomes after minimally invasive surgery for aortic valve replacement are at least comparable to those achieved with median sternotomy. The length of the hospital stay was reduced by minimally invasive surgery in our single-institution experience. The retrospective nature of this study warrants further randomized prospective trials to validate our results. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights

  1. Absence of posterior tricuspid valve leaflet and valve reconstruction

    PubMed Central

    Komoda, Takeshi; Stamm, Christof; Fleck, Eckart; Hetzer, Roland

    2012-01-01

    We report a rare case of the absence of a posterior tricuspid valve leaflet. A male patient, aged 46, suffering from severe tricuspid valve regurgitation (TR) of unknown aetiology and atrial septal aneurysm was referred to our hospital for surgery. On surgical inspection, the posterior tricuspid valve leaflet and its subvalvular apparatus were completely absent and only the valve annulus was seen in the corresponding position. The anterior and septal leaflets were normal. We successfully reconstructed the tricuspid valve as follows: the head of an anterior papillary muscle was approximated to the ventricular septum (Sebening stitch). After the approximation of the centre of the tricuspid annulus of the anterior leaflet to the tricuspid annulus on the opposite side, a sizer of 29 mm in diameter was easily passed through the anterior orifice. The posterior orifice was closed with running sutures (posterior annulorrhaphy after Hetzer). Before these procedures, we attempted to reconstruct the tricuspid valve with a posterior annulorrhaphy alone; however, valve competence was insufficient. A Sebening stitch was necessary to improve the valve competence. Echocardiography showed TR grade 1 at the patient's discharge from hospital and TR grade 1 to 2 at the follow-up, 10 months after the operation. PMID:22419794

  2. Impact of Early Valve Surgery on Outcome of Staphylococcus aureus Prosthetic Valve Infective Endocarditis: Analysis in the International Collaboration of Endocarditis–Prospective Cohort Study

    PubMed Central

    Chirouze, Catherine; Alla, François; Fowler, Vance G.; Sexton, Daniel J.; Corey, G. Ralph; Chu, Vivian H.; Wang, Andrew; Erpelding, Marie-Line; Durante-Mangoni, Emanuele; Fernández-Hidalgo, Nuria; Giannitsioti, Efthymia; Hannan, Margaret M.; Lejko-Zupanc, Tatjana; Miró, José M.; Muñoz, Patricia; Murdoch, David R.; Tattevin, Pierre; Tribouilloy, Christophe; Hoen, Bruno; Clara, Liliana; Sanchez, Marisa; Nacinovich, Francisco; Oses, Pablo Fernandez; Ronderos, Ricardo; Sucari, Adriana; Thierer, Jorge; Casabé, José; Cortes, Claudia; Altclas, Javier; Kogan, Silvia; Spelman, Denis; Athan, Eugene; Harris, Owen; Kennedy, Karina; Tan, Ren; Gordon, David; Papanicolas, Lito; Eisen, Damon; Grigg, Leeanne; Street, Alan; Korman, Tony; Kotsanas, Despina; Dever, Robyn; Jones, Phillip; Konecny, Pam; Lawrence, Richard; Rees, David; Ryan, Suzanne; Feneley, Michael P.; Harkness, John; Jones, Phillip; Ryan, Suzanne; Jones, Phillip; Ryan, Suzanne; Jones, Phillip; Post, Jeffrey; Reinbott, Porl; Ryan, Suzanne; Gattringer, Rainer; Wiesbauer, Franz; Andrade, Adriana Ribas; de Brito, Ana Cláudia Passos; Guimarães, Armenio Costa; Grinberg, Max; Mansur, Alfredo José; Siciliano, Rinaldo Focaccia; Strabelli, Tania Mara Varejao; Vieira, Marcelo Luiz Campos; de Medeiros Tranchesi, Regina Aparecida; Paiva, Marcelo Goulart; Fortes, Claudio Querido; de Oliveira Ramos, Auristela; Ferraiuoli, Giovanna; Golebiovski, Wilma; Lamas, Cristiane; Santos, Marisa; Weksler, Clara; Karlowsky, James A.; Keynan, Yoav; Morris, Andrew M.; Rubinstein, Ethan; Jones, Sandra Braun; Garcia, Patricia; Cereceda, M; Fica, Alberto; Mella, Rodrigo Montagna; Barsic, Bruno; Bukovski, Suzana; Krajinovic, Vladimir; Pangercic, Ana; Rudez, Igor; Vincelj, Josip; Freiberger, Tomas; Pol, Jiri; Zaloudikova, Barbora; Ashour, Zainab; El Kholy, Amani; Mishaal, Marwa; Rizk, Hussien; Aissa, Neijla; Alauzet, Corentine; Alla, Francois; Campagnac, Catherine; Doco-Lecompte, Thanh; Selton-Suty, Christine; Casalta, Jean-Paul; Fournier, Pierre-Edouard; Habib, Gilbert; Raoult, Didier; Thuny, Franck; Delahaye, François; Delahaye, Armelle; Vandenesch, Francois; Donal, Erwan; Donnio, Pierre Yves; Michelet, Christian; Revest, Matthieu; Tattevin, Pierre; Violette, Jérémie; Chevalier, Florent; Jeu, Antoine; Sorel, Claire; Tribouilloy, Christophe; Bernard, Yvette; Chirouze, Catherine; Hoen, Bruno; Leroy, Joel; Plesiat, Patrick; Naber, Christoph; Neuerburg, Carl; Mazaheri, Bahram; Naber, Christoph; Neuerburg, Carl; Athanasia, Sofia; Giannitsioti, Efthymia; Mylona, Elena; Paniara, Olga; Papanicolaou, Konstantinos; Pyros, John; Skoutelis, Athanasios; Sharma, Gautam; Francis, Johnson; Nair, Lathi; Thomas, Vinod; Venugopal, Krishnan; Hannan, Margaret; Hurley, John; Gilon, Dan; Israel, Sarah; Korem, Maya; Strahilevitz, Jacob; Rubinstein, Ethan; Strahilevitz, Jacob; Casillo, Roberta; Cuccurullo, Susanna; Dialetto, Giovanni; Durante-Mangoni, Emanuele; Irene, Mattucci; Ragone, Enrico; Tripodi, Marie Françoise; Utili, Riccardo; Cecchi, Enrico; De Rosa, Francesco; Forno, Davide; Imazio, Massimo; Trinchero, Rita; Tebini, Alessandro; Grossi, Paolo; Lattanzio, Mariangela; Toniolo, Antonio; Goglio, Antonio; Raglio, Annibale; Ravasio, Veronica; Rizzi, Marco; Suter, Fredy; Carosi, Giampiero; Magri, Silvia; Signorini, Liana; Baban, Tania; Kanafani, Zeina; Kanj, Souha S.; Yasmine, Mohamad; Abidin, Imran; Tamin, Syahidah Syed; Martínez, Eduardo Rivera; Soto Nieto, Gabriel Israel; van der Meer, Jan T.M.; Chambers, Stephen; Holland, David; Morris, Arthur; Raymond, Nigel; Read, Kerry; Murdoch, David R.; Dragulescu, Stefan; Ionac, Adina; Mornos, Cristian; Butkevich, O.M.; Chipigina, Natalia; Kirill, Ozerecky; Vadim, Kulichenko; Vinogradova, Tatiana; Edathodu, Jameela; Halim, Magid; Lum, Luh-Nah; Tan, Ru-San; Lejko-Zupanc, Tatjana; Logar, Mateja; Mueller-Premru, Manica; Commerford, Patrick; Commerford, Anita; Deetlefs, Eduan; Hansa, Cass; Ntsekhe, Mpiko; Almela, Manuel; Armero, Yolanda; Azqueta, Manuel; Castañeda, Ximena; Cervera, Carlos; del Rio, Ana; Falces, Carlos; Garcia-de-la-Maria, Cristina; Fita, Guillermina; Gatell, Jose M.; Marco, Francesc; Mestres, Carlos A.; Miró, José M.; Moreno, Asuncion; Ninot, Salvador; Paré, Carlos; Pericas, Joan; Ramirez, Jose; Rovira, Irene; Sitges, Marta; Anguera, Ignasi; Font, Bernat; Guma, Joan Raimon; Bermejo, Javier; Bouza, Emilio; Fernández, Miguel Angel Garcia; Gonzalez-Ramallo, Victor; Marín, Mercedes; Muñoz, Patricia; Pedromingo, Miguel; Roda, Jorge; Rodríguez-Créixems, Marta; Solis, Jorge; Almirante, Benito; Fernandez-Hidalgo, Nuria; Tornos, Pilar; de Alarcón, Arístides; Parra, Ricardo; Alestig, Eric; Johansson, Magnus; Olaison, Lars; Snygg-Martin, Ulrika; Pachirat, Orathai; Pachirat, Pimchitra; Pussadhamma, Burabha; Senthong, Vichai; Casey, Anna; Elliott, Tom; Lambert, Peter; Watkin, Richard; Eyton, Christina; Klein, John L.; Bradley, Suzanne; Kauffman, Carol; Bedimo, Roger; Chu, Vivian H.; Corey, G. Ralph; Crowley, Anna Lisa; Douglas, Pamela; Drew, Laura; Fowler, Vance G.; Holland, Thomas; Lalani, Tahaniyat; Mudrick, Daniel; Samad, Zaniab; Sexton, Daniel; Stryjewski, Martin; Wang, Andrew; Woods, Christopher W.; Lerakis, Stamatios; Cantey, Robert; Steed, Lisa; Wray, Dannah; Dickerman, Stuart A.; Bonilla, Hector; DiPersio, Joseph; Salstrom, Sara-Jane; Baddley, John; Patel, Mukesh; Peterson, Gail; Stancoven, Amy; Afonso, Luis; Kulman, Theresa; Levine, Donald; Rybak, Michael; Cabell, Christopher H.; Baloch, Khaula; Chu, Vivian H.; Corey, G. Ralph; Dixon, Christy C.; Fowler, Vance G.; Harding, Tina; Jones-Richmond, Marian; Pappas, Paul; Park, Lawrence P.; Redick, Thomas; Stafford, Judy; Anstrom, Kevin; Athan, Eugene; Bayer, Arnold S.; Cabell, Christopher H.; Chu, Vivian H.; Corey, G. Ralph; Fowler, Vance G.; Hoen, Bruno; Karchmer, A. W.; Miró, José M.; Murdoch, David R.; Sexton, Daniel J.; Wang, Andrew; Bayer, Arnold S.; Cabell, Christopher H.; Chu, Vivian; Corey, G. Ralph; Durack, David T.; Eykyn, Susannah; Fowler, Vance G.; Hoen, Bruno; Miró, José M.; Moreillon, Phillipe; Olaison, Lars; Raoult, Didier; Rubinstein, Ethan; Sexton, Daniel J.

    2015-01-01

    Background. The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis–Prospective Cohort Study. Methods. Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. Results. EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non–S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39–1.15]; P = .15). Conclusions. In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE. PMID:25389255

  3. Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery.

    PubMed

    Popma, Jeffrey J; Adams, David H; Reardon, Michael J; Yakubov, Steven J; Kleiman, Neal S; Heimansohn, David; Hermiller, James; Hughes, G Chad; Harrison, J Kevin; Coselli, Joseph; Diez, Jose; Kafi, Ali; Schreiber, Theodore; Gleason, Thomas G; Conte, John; Buchbinder, Maurice; Deeb, G Michael; Carabello, Blasé; Serruys, Patrick W; Chenoweth, Sharla; Oh, Jae K

    2014-05-20

    This study sought to evaluate the safety and efficacy of the CoreValve transcatheter heart valve (THV) for the treatment of severe aortic stenosis in patients at extreme risk for surgery. Untreated severe aortic stenosis is a progressive disease with a poor prognosis. Transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis is a potentially effective therapy. We performed a prospective, multicenter, nonrandomized investigation evaluating the safety and efficacy of self-expanding TAVR in patients with symptomatic severe aortic stenosis with prohibitive risks for surgery. The primary endpoint was a composite of all-cause mortality or major stroke at 12 months, which was compared with a pre-specified objective performance goal (OPG). A total of 41 sites in the United States recruited 506 patients, of whom 489 underwent attempted treatment with the CoreValve THV. The rate of all-cause mortality or major stroke at 12 months was 26.0% (upper 2-sided 95% confidence bound: 29.9%) versus 43.0% with the OPG (p < 0.0001). Individual 30-day and 12-month events included all-cause mortality (8.4% and 24.3%, respectively) and major stroke (2.3% and 4.3%, respectively). Procedural events at 30 days included life-threatening/disabling bleeding (12.7%), major vascular complications (8.2%), and need for permanent pacemaker placement (21.6%). The frequency of moderate or severe paravalvular aortic regurgitation was lower 12 months after self-expanding TAVR (4.2%) than at discharge (10.7%; p = 0.004 for paired analysis). TAVR with a self-expanding bioprosthesis was safe and effective in patients with symptomatic severe aortic stenosis at prohibitive risk for surgical valve replacement. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2014 American College of Cardiology Foundation. Published by

  4. Update of transcatheter valve treatment

    PubMed Central

    Liu, Xian-bao; Wang, Jian-an

    2013-01-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair—MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed. PMID:23897785

  5. Impact of same-session trabectome surgery on Ahmed glaucoma valve outcomes.

    PubMed

    Esfandiari, Hamed; Shazly, Tarek; Shah, Priyal; Hassanpour, Kiana; Torkian, Pooya; Yaseri, Mehdi; Loewen, Nils A

    2018-03-30

    To evaluate the efficacy and survival rates of same session ab interno trabeculectomy with the trabectome and Ahmed glaucoma valve implant (AT) in comparison to the Ahmed glaucoma valve alone (A). A total of 107 eyes undergoing primary glaucoma surgery were enrolled in this retrospective comparative case series, including 48 eyes which underwent AT and 59 eyes which received A alone. Participants were identified using the procedural terminology codes, and their medical records were reviewed. The primary outcome measure was success defined as IOP > 5 mmHg, ≤ 21 mmHg and ≥ 20% reduction of IOP from baseline at two consecutive visits after 3 months, and no need for glaucoma reoperation. Secondary outcome measures were IOP, the number of glaucoma medications, incidence of a hypertensive phase, and best corrected visual acuity (BCVA). The cumulative probability of success at 1 year was 70% in AT, and 65% in A (p = 0.85). IOP decreased significantly from 26.6 ± 10.1 mmHg at baseline to 14.7 ± 3.3 mmHg at the final follow-up in AT (p = 0.001). The corresponding numbers for A were 27.8 ± 10.2 and 16.7 ± 4.9, respectively (p = 0.001). The final IOP was significantly lower in AT (p = 0.022). The number of medications at baseline was comparable in both groups (2.6 ± 1.2 in AT and 2.5 ± 1.3 in A, p = 0.851). Corresponding number at 1 year visit was 1.2 ± 2 in AT and 2.8 ± 1.8 in A (p = 0.001). The incidence of a hypertensive phase was 18.7% in AT and 35.5% in A (p = 0.05). HP resolved in only 30% of eyes. The criteria for HP resolution were fulfilled in 9 eyes (30%). There was no difference in the rate of resolution of the hypertensive phase between AT and A (33.3 and 28.5%, respectively, p = 0.67). Ahmed glaucoma valve implant with same session trabectome surgery significantly decreased the rate of the hypertensive phase and postoperative IOP as well as the number of glaucoma

  6. Dual infection by streptococcus and atypical mycobacteria following Ahmed glaucoma valve surgery.

    PubMed

    Rao, Aparna; Wallang, Batriti; Padhy, Tapas Ranjan; Mittal, Ruchi; Sharma, Savitri

    2013-07-01

    To report a case of late postoperative endophthalmitis caused by Streptococcus pneumoniae and conjunctival necrosis by Streptococcus pneumoniae and Mycobacterium fortuitum following Ahmed glaucoma valve (AGV) surgery in a young patient. Case report of a 13-year-old boy with purulent exudates and extensive conjunctival necrosis two months following amniotic membrane graft and conjunctival closure (for conjunctival retraction post AGV for secondary glaucoma). The conjunctiva showed extensive necrosis causing exposure of the tube and plate associated with frank exudates in the area adjoining the plate and anterior chamber mandating explantation of the plate along with intravitreal antibiotics. The vitreous aspirate grew Streptococcus pneumoniae while Streptococcus pneumoniae with Mycobacterium fortuitum was isolated from the explanted plate. Despite adequate control of infection following surgery, the final visual outcome was poor owing to disc pallor. Conjunctival necrosis and retraction post-AGV can cause late postoperative co-infections by fulminant and slow-growing organisms. A close follow-up is therefore essential in these cases to prevent sight-threatening complications.

  7. Partial Tenon’s capsule resection with adjunctive mitomycin C in Ahmed glaucoma valve implant surgery

    PubMed Central

    Susanna, R

    2003-01-01

    Aim: To verify if partial intraoperative Tenon’s capsule resection (PTCR) with adjunctive mitomycin C is effective in developing thin, avascular blebs in eyes undergoing Ahmed glaucoma valve insertion, and to assess the efficacy and safety of this procedure. Methods: A multicentre, prospective, alternating case assignment, investigator unmasked, parallel group, comparative interventional study was conducted in four Latin American countries (Argentina, Brazil, Colombia, and Peru). Ahmed glaucoma valve implant insertion with PTCR (group A) and without PCTR (group B) was performed in neovascular glaucomatous eyes without previous surgery. Adjunctive mitomycin C (MMC) was used in both groups. Patients were examined 1 day, 10 days, 1 month, 2 months, 3 months, 6 months, and 1 year following the surgery. Intraocular pressure (IOP) and the appearance of the bleb were evaluated at each examination. Appearance of the bleb was classified at both the 1 month mark and last examinations into one of three groups: flat and vascularised; elevated avascular; or elevated and not avascular. Results: 92 eyes from 92 patients were included in the study. The preoperative mean IOP was 50.0 (SD 10.5) mm Hg in group A and 48.4 (11.7) in group B (p>0.05). Statistically significant IOP reductions were observed at all periods of follow up. 12 months after surgery, the mean IOP was 17.2 (5.0) mm Hg in group A and 18.3 (8.7) mm Hg in group B (p>0.05). A hypertensive phase occurred in 40.0% in group A and in 46.8% in group B (p>0.05). At the 1 month and the final follow up, the blebs in all eyes were considered elevated and not avascular. The success rate (IOP⩽21 mm Hg) at 1 year after surgery was 70.4% in group A and 77.7% in group B (p>0.05). Overall, 74.2% of the patients achieved an IOP ⩽21 mm Hg and 55.2% an IOP⩽17 mm Hg, with or without additional medication administered to lower IOP. The incidence of complications was similar in both groups. Conclusions: In eyes undergoing Ahmed

  8. How to start a minimal access mitral valve program.

    PubMed

    Hunter, Steven

    2013-11-01

    The seven pillars of governance established by the National Health Service in the United Kingdom provide a useful framework for the process of introducing new procedures to a hospital. Drawing from local experience, the author present guidance for institutions considering establishing a minimal access mitral valve program. The seven pillars of governance apply to the practice of minimally invasive mitral valve surgery, based on the principle of patient-centred practice. The author delineate the benefits of minimally invasive mitral valve surgery in terms of: "clinical effectiveness", including reduced length of hospital stay, "risk management effectiveness", including conversion to sternotomy and aortic dissection, "patient experience" including improved cosmesis and quicker recovery, and the effectiveness of communication, resources and strategies in the implementation of minimally invasive mitral valve surgery. Finally, the author have identified seven learning curves experienced by surgeons involved in introducing a minimal access mitral valve program. The learning curves are defined as: techniques of mitral valve repair, Transoesophageal Echocardiography-guided cannulation, incisions, instruments, visualization, aortic occlusion and cardiopulmonary bypass strategies. From local experience, the author provide advice on how to reduce the learning curves, such as practising with the specialised instruments and visualization techniques during sternotomy cases. Underpinning the NHS pillars are the principles of systems awareness, teamwork, communication, ownership and leadership, all of which are paramount to performing any surgery but more so with minimal access surgery, as will be highlighted throughout this paper.

  9. How to start a minimal access mitral valve program

    PubMed Central

    2013-01-01

    The seven pillars of governance established by the National Health Service in the United Kingdom provide a useful framework for the process of introducing new procedures to a hospital. Drawing from local experience, the author present guidance for institutions considering establishing a minimal access mitral valve program. The seven pillars of governance apply to the practice of minimally invasive mitral valve surgery, based on the principle of patient-centred practice. The author delineate the benefits of minimally invasive mitral valve surgery in terms of: “clinical effectiveness”, including reduced length of hospital stay, “risk management effectiveness”, including conversion to sternotomy and aortic dissection, “patient experience” including improved cosmesis and quicker recovery, and the effectiveness of communication, resources and strategies in the implementation of minimally invasive mitral valve surgery. Finally, the author have identified seven learning curves experienced by surgeons involved in introducing a minimal access mitral valve program. The learning curves are defined as: techniques of mitral valve repair, Transoesophageal Echocardiography-guided cannulation, incisions, instruments, visualization, aortic occlusion and cardiopulmonary bypass strategies. From local experience, the author provide advice on how to reduce the learning curves, such as practising with the specialised instruments and visualization techniques during sternotomy cases. Underpinning the NHS pillars are the principles of systems awareness, teamwork, communication, ownership and leadership, all of which are paramount to performing any surgery but more so with minimal access surgery, as will be highlighted throughout this paper. PMID:24349981

  10. Ahmed glaucoma valve implant: surgical technique and complications.

    PubMed

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  11. Ahmed glaucoma valve implant: surgical technique and complications

    PubMed Central

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios GP; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. PMID:28255226

  12. Respiratory System Function in Patients After Minimally Invasive Aortic Valve Replacement Surgery: A Case Control Study.

    PubMed

    Stoliński, Jarosław; Musiał, Robert; Plicner, Dariusz; Andres, Janusz

    The aim of the study was to comparatively analyze respiratory system function after minimally invasive, through right minithoracotomy aortic valve replacement (RT-AVR) to conventional AVR. Analysis of 201 patients scheduled for RT-AVR and 316 for AVR between January 2010 and November 2013. Complications of the respiratory system and pulmonary functional status are presented. Complications of the respiratory system occurred in 16.8% of AVR and 11.0% of RT-AVR patients (P = 0.067). The rate of pleural effusions, thoracenteses, pneumonias, or phrenic nerve dysfunctions was not significantly different between groups. Perioperative mortality was 1.9% in AVR and 1.0% in RT-AVR (P = 0.417). Mechanical ventilation time after surgery was 9.7 ± 5.9 hours for AVR and 7.2 ± 3.2 hours for RT-AVR patients (P < 0.001). Stroke (odds ratio [OR] = 13.4, P = 0.008), increased postoperative blood loss (OR = 9.6, P < 0.001), and chronic obstructive pulmonary disease (OR = 7.7, P < 0.001) were risk factors of prolonged mechanical lung ventilation. A week after surgery, the results of most pulmonary function tests were lower in the AVR than in the RT-AVR group (P < 0.001 was seen for forced expiratory volume in the first second, vital capacity, total lung capacity, maximum inspiratory pressure and maximum expiratory pressure, P = 0.377 was seen for residual volume). Right anterior aortic valve replacement minithoracotomy surgery with single-lung ventilation did not result in increased rate of respiratory system complications. Spirometry examinations revealed that pulmonary functional status was more impaired after AVR in comparison with RT-AVR surgery.

  13. The German Aortic Valve Registry (GARY): in-hospital outcome

    PubMed Central

    Hamm, Christian W.; Möllmann, Helge; Holzhey, David; Beckmann, Andreas; Veit, Christof; Figulla, Hans-Reiner; Cremer, J.; Kuck, Karl-Heinz; Lange, Rüdiger; Zahn, Ralf; Sack, Stefan; Schuler, Gerhard; Walther, Thomas; Beyersdorf, Friedhelm; Böhm, Michael; Heusch, Gerd; Funkat, Anne-Kathrin; Meinertz, Thomas; Neumann, Till; Papoutsis, Konstantinos; Schneider, Steffen; Welz, Armin; Mohr, Friedrich W.

    2014-01-01

    Background Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. Methods and results A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). Conclusion The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients. PMID:24022003

  14. Minimally invasive mitral valve repair in osteogenesis imperfecta.

    PubMed

    Tagliasacchi, Isabella; Martinelli, Luigi; Bardaro, Leopoldo; Chierchia, Sergio

    2017-10-01

    Osteogenesis imperfecta is a disorder of the connective tissue that affects several structures including heart valves. However, cardiac surgery is associated with high mortality and morbidity rates. In a 48-year-old man with osteogenesis imperfecta and mitral valve prolapse, we performed the first successful mitral valve repair by right anterior mini-thoracotomy. At the 1-year follow-up, he was asymptomatic and echocardiography confirmed the initial success. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Impact of early valve surgery on outcome of Staphylococcus aureus prosthetic valve infective endocarditis: analysis in the International Collaboration of Endocarditis-Prospective Cohort Study.

    PubMed

    Chirouze, Catherine; Alla, François; Fowler, Vance G; Sexton, Daniel J; Corey, G Ralph; Chu, Vivian H; Wang, Andrew; Erpelding, Marie-Line; Durante-Mangoni, Emanuele; Fernández-Hidalgo, Nuria; Giannitsioti, Efthymia; Hannan, Margaret M; Lejko-Zupanc, Tatjana; Miró, José M; Muñoz, Patricia; Murdoch, David R; Tattevin, Pierre; Tribouilloy, Christophe; Hoen, Bruno

    2015-03-01

    The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis-Prospective Cohort Study. Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non-S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39-1.15]; P = .15). In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. [Quality of life or life expectancy? Criteria and sources of information in the decision-making of patients undergoing aortic valve surgery].

    PubMed

    Schmied, Wolfram; Barnick, Saskia; Heimann, Dierk; Schäfers, Hans-Joachim; Köllner, Volker

    2015-01-01

    Physicians are expected to involve patients adequately in the decision-making process prior to surgery. To this end, it is essential to have knowledge about the potential reasons for such a decision. In this study we investigated which information sources and decision criteria are important to patients prior to aortic valve surgery. A consecutive sample of 468 patients (70.1%m, aged 66.9±14.2 years) was examined 2 years after aortic valve replacement or reconstruction with a self-developed questionnaire. Preoperative discussion with a cardiologist or a cardiac surgeon was the information source patients used most frequently and felt to be the most helpful. The most important decision criterion was quality of life, followed by life expectancy and likelihood of reoperation. Two years postoperatively, 97.3% of the patients were satisfied with their decision. Preoperative counseling by a physician plays an essential role in the decision-making process prior to cardiac surgery. Patients want to be involved in decision-making, though they do not want to bear the full responsibility.

  17. Quality and Safety in Health Care, Part XXX: Transcatheter Aortic Valve Therapy.

    PubMed

    Harolds, Jay A

    2017-12-01

    Initially, the transcatheter aortic valve replacement procedure was approved only for patients with aortic stenosis that was both severe and symptomatic who either also had too high a risk of aortic valve replacement surgery to have the surgery or who had a high risk for the surgery. Between the years 2012 and 2015, the death rate at 30 days declined from an initial rate of 7.5% to 4.6%. There has also been more use of the transfemoral approach over the years. In 2016, the transcatheter aortic valve replacement was approved for patients with aortic stenosis at intermediate risk of surgery.

  18. Transcatheter aortic valve replacement in patients with severe mitral or tricuspid regurgitation at extreme risk for surgery.

    PubMed

    Little, Stephen H; Popma, Jeffrey J; Kleiman, Neal S; Deeb, G Michael; Gleason, Thomas G; Yakubov, Steven J; Checuti, Stan; O'Hair, Daniel; Bajwa, Tanvir; Mumtaz, Mubashir; Maini, Brijeshwar; Hartman, Alan; Katz, Stanley; Robinson, Newell; Petrossian, George; Heiser, John; Merhi, William; Moore, B Jane; Li, Shuzhen; Adams, David H; Reardon, Michael J

    2018-05-01

    Patients with symptomatic severe aortic stenosis and severe mitral regurgitation or severe tricuspid regurgitation were excluded from the major transcatheter aortic valve replacement trials. We studied these 2 subgroups in patients at extreme risk for surgery in the prospective, nonrandomized, single-arm CoreValve US Expanded Use Study. The primary end point was all-cause mortality or major stroke at 1 year. A favorable medical benefit was defined as a Kansas City Cardiomyopathy Questionnaire overall summary score greater than 45 at 6 months and greater than 60 at 1 year and with a less than 10-point decrease from baseline. There were 53 patients in each group. Baseline characteristics for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were age 84.2 ± 6.4 years and 84.9 ± 6.5 years; male, 29 (54.7%) and 22 (41.5%), and mean Society of Thoracic Surgeons score 9.9% ± 5.0% and 9.2% ± 4.0%, respectively. Improvement in valve regurgitation from baseline to 1 year occurred in 72.7% of the patients with severe mitral regurgitation and in 61.8% of patients with severe tricuspid regurgitation. A favorable medical benefit occurred in 31 of 47 patients (66.0%) with severe mitral regurgitation and 33 of 47 patients (70.2%) with severe tricuspid regurgitation at 6 months, and in 25 of 44 patients (56.8%) with severe mitral regurgitation and 24 of 45 patients (53.3%) with severe tricuspid regurgitation at 1 year. All-cause mortality or major stroke for the severe mitral regurgitation and severe tricuspid regurgitation cohorts were 11.3% and 3.8% at 30 days and 21.0% and 19.2% at 1 year, respectively. There were no major strokes in either group at 1 year. Transcatheter aortic valve replacement in patients with severe mitral regurgitation or severe tricuspid regurgitation is reasonable and safe and leads to improvement in atrioventricular valve regurgitation. Copyright © 2018 The American Association for Thoracic Surgery

  19. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    PubMed

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  20. Tricuspid valve endocarditis

    PubMed Central

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  1. Mitral Valve Prolapse

    MedlinePlus

    ... valve. MVP puts you at risk for infective endocarditis, a kind of heart infection. To prevent it, ... surgeries. Now, only people at high risk of endocarditis need the antibiotics. NIH: National Heart, Lung, and ...

  2. Urodynamic changes in patients with anterior urethral valves: before and after endoscopic valve ablation.

    PubMed

    Kajbafzadeh, Abdol-Mohammad; Payabvash, Seyedmehdi; Karimian, Golnar

    2007-08-01

    To retrospectively review a series of children with anterior urethral valves (AUV), with emphasis on patterns of urodynamic change and long-term outcome of endoscopic treatment. We reviewed the medical records of eight patients who had undergone thorough radiological and urodynamic exams before and after treatment. The diagnosis of AUV was based on radiological imaging and confirmed by urethrocystoscopy. The valves were ablated through either transurethral fulguration or resection. The upper urinary tracts were studied by renal scan and ultrasonography before and after the procedure. Bladder function was assessed urodynamically 3 months after surgery. Uroflowmetry was performed as soon as the children were toilet trained. Endoscopic ablation of AUV was successful in all cases and no surgical complications occurred. The initial symptoms resolved in all boys. VUR disappeared in two out of three patients, and five children had bladder trabeculation that was resolved after surgery. The final outcome was successful in seven patients (88%). The major urodynamic dysfunction was bladder hypercontractility that resolved following valve ablation. The mean maximum voiding detrusor pressure (P(detmax)) decreased from 213.2+/-17.9 cmH(2)O to 80.7+/-9.9 cmH(2)O, 6 months after treatment (P<0.001). None of the patients had low-compliant bladder, detrusor instability or myogenic failure. The voiding pattern in all toilet-trained patients was staccato and of an interrupted shape prior to surgery, but changed to a normal bell-shaped voiding pattern following valve ablation. AUV should be considered in the differential diagnosis of patients presenting with infravesical obstruction. We recommend endoscopic valve ablation as the treatment of choice.

  3. Update to the study protocol, including statistical analysis plan for a randomized clinical trial comparing comprehensive cardiac rehabilitation after heart valve surgery with control: the CopenHeartVR trial.

    PubMed

    Sibilitz, Kirstine Laerum; Berg, Selina Kikkenborg; Hansen, Tina Birgitte; Risom, Signe Stelling; Rasmussen, Trine Bernholdt; Hassager, Christian; Køber, Lars; Gluud, Christian; Thygesen, Lau Caspar; Lindschou, Jane; Schmid, Jean Paul; Taylor, Rod S; Zwisler, Ann-Dorthe

    2015-02-05

    Heart valve diseases are common with an estimated prevalence of 2.5% in the Western world. The number is rising because of an ageing population. Once symptomatic, heart valve diseases are potentially lethal, and heavily influence daily living and quality of life. Surgical treatment, either valve replacement or repair, remains the treatment of choice. However, post-surgery, the transition to daily living may become a physical, mental and social challenge. We hypothesize that a comprehensive cardiac rehabilitation program can improve physical capacity and self-assessed mental health and reduce hospitalization and healthcare costs after heart valve surgery. This randomized clinical trial, CopenHeartVR, aims to investigate whether cardiac rehabilitation in addition to usual care is superior to treatment as usual after heart valve surgery. The trial will randomly allocate 210 patients 1:1 to an intervention or a control group, using central randomization, and blinded outcome assessment and statistical analyses. The intervention consists of 12 weeks of physical exercise and a psycho-educational intervention comprising five consultations. The primary outcome is peak oxygen uptake (VO2 peak) measured by cardiopulmonary exercise testing with ventilatory gas analysis. The secondary outcome is self-assessed mental health measured by the standardized questionnaire Short Form-36. Long-term healthcare utilization and mortality as well as biochemistry, echocardiography and cost-benefit will be assessed. A mixed-method design will be used to evaluate qualitative and quantitative findings, encompassing a survey-based study before the trial and a qualitative pre- and post-intervention study. This randomized clinical trial will contribute with evidence of whether cardiac rehabilitation should be provided after heart valve surgery. The study is approved by the local regional Research Ethics Committee (H-1-2011-157), and the Danish Data Protection Agency (j.nr. 2007-58-0015). Trial

  4. Minimally invasive versus conventional extracorporeal circulation in minimally invasive cardiac valve surgery.

    PubMed

    Baumbach, Hardy; Rustenbach, Christian; Michaelsen, Jens; Hipp, Gernot; Pressmar, Markus; Leinweber, Marco; Franke, Ulrich Friedrich Wilhelm

    2014-02-01

    Minimally invasive extracorporeal circulation (MECC) technology was applied predominantly in coronary surgery. Data regarding the application of MECC in minimally invasive valve surgery are missing largely. Patients undergoing isolated minimally invasive mitral or aortic valve procedures were allocated either to conventional extracorporeal circulation (CECC) group (n = 63) or MECC group (n = 105), and their prospectively generated data were analyzed. Demographic data were comparable between the groups regarding age (CECC vs. MECC: 71.0 ± 7.5 vs. 66.2 ± 10.1 years, p = 0.091) and logistic EuroSCORE I (6.2 ± 2.5 vs. 5.4 ± 3.0, p = 0.707). Hospital mortality was one patient in each group (1.6 vs. 1.0%, p = 0.688). The levels of leukocytes were lower in the MECC group (11.6 ± 3.2 vs. 9.4 ± 4.3 109/L, p = 0.040). Levels of platelets (137.2 ± 45.5 vs. 152.4 ± 50.3 109/L, p = 0.015) and hemoglobin (103.3 ± 11.3 vs. 107.3 ± 14.7 g/L, p = 0.017) were higher in the MECC group. Renal function was better preserved (creatinine: 1.1 ± 0.4 vs. 0.9 ± 0.2 mg/dL, p = 0.019). We were able to validate shorter time of postoperative ventilation (9.5 ± 15.1 vs. 6.3 ± 3.4 h, p = 0.054) as well as significantly shorter intensive care unit (ICU) stay (1.8 ± 1.3 vs. 1.2 ± 1.0 d, p = 0.005) for MECC patients. The course of C-reactive protein did not differ between the groups. We were able to prove the feasibility of MECC even in minimally invasive performed mitral and aortic valve procedures. In addition, the use of MECC provides decreased platelet consumption and less hemodilution. The use of MECC in these selected patients lead to a shorter ventilation time and ICU stay. Georg Thieme Verlag KG Stuttgart · New York.

  5. Patient-specific pediatric silicone heart valve models based on 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.

  6. Electromagnetic Spectroscopy of Normal Breast Tissue Specimens Obtained From Reduction Surgeries: Comparison of Optical and Microwave Properties

    PubMed Central

    Lazebnik, Mariya; Zhu, Changfang; Palmer, Gregory M.; Harter, Josephine; Sewall, Sarah; Ramanujam, Nirmala; Hagness, Susan C.

    2009-01-01

    Techniques utilizing electromagnetic energy at microwave and optical frequencies have been shown to be promising for breast cancer detection and diagnosis. Since different biophysical mechanisms are exploited at these frequencies to discriminate between healthy and diseased tissue, combining these two modalities may result in a more powerful approach for breast cancer detection and diagnosis. Toward this end, we performed microwave dielectric spectroscopy and optical diffuse reflectance spectroscopy measurements at the same sites on freshly-excised normal breast tissues obtained from reduction surgeries at the University of Wisconsin Hospital, using microwave and optical probes with very similar sensing volumes. We found that the microwave dielectric constant and effective conductivity are correlated with tissue composition across the entire measurement frequency range (|r|~0.5–0.6, p<0.01), and that the optical absorption coefficient at 460 nm and optical scattering coefficient are correlated with tissue composition (|r|~ 0.4–0.6, p<0.02). Finally, we found that the optical absorption coefficient at 460 nm is correlated with the microwave dielectric constant and effective conductivity (r=−0.55, p<0.01). Our results suggest that combining optical and microwave modalities for analyzing breast tissue samples may serve as a crosscheck and provide complementary information about tissue composition. PMID:18838370

  7. Electromagnetic spectroscopy of normal breast tissue specimens obtained from reduction surgeries: comparison of optical and microwave properties.

    PubMed

    Lazebnik, Mariya; Zhu, Changfang; Palmer, Gregory M; Harter, Josephine; Sewall, Sarah; Ramanujam, Nirmala; Hagness, Susan C

    2008-10-01

    Techniques utilizing electromagnetic energy at microwave and optical frequencies have been shown to be promising for breast cancer detection and diagnosis. Since different biophysical mechanisms are exploited at these frequencies to discriminate between healthy and diseased tissue, combining these two modalities may result in a more powerful approach for breast cancer detection and diagnosis. Toward this end, we performed microwave dielectric spectroscopy and optical diffuse reflectance spectroscopy measurements at the same sites on freshly excised normal breast tissues obtained from reduction surgeries at the University of Wisconsin Hospital, using microwave and optical probes with very similar sensing volumes. We found that the microwave dielectric constant and effective conductivity are correlated with tissue composition across the entire measurement frequency range (|r| approximately 0.5-0.6, p<0.01) and that the optical absorption coefficient at 460 nm and optical scattering coefficient are correlated with tissue composition (|r| approximately 0.4-0.6, p<0.02). Finally, we found that the optical absorption coefficient at 460 nm is correlated with the microwave dielectric constant and effective conductivity (r=-0.55, p<0.01). Our results suggest that combining optical and microwave modalities for analyzing breast tissue samples may serve as a crosscheck and provide complementary information about tissue composition.

  8. Predictors of in-hospital mortality after mitral valve surgery for post-myocardial infarction papillary muscle rupture.

    PubMed

    Bouma, Wobbe; Wijdh-den Hamer, Inez J; Koene, Bart M; Kuijpers, Michiel; Natour, Ehsan; Erasmus, Michiel E; van der Horst, Iwan C C; Gorman, Joseph H; Gorman, Robert C; Mariani, Massimo A

    2014-10-18

    Papillary muscle rupture (PMR) is a rare, but often life-threatening mechanical complication of myocardial infarction (MI). Immediate surgical intervention is considered the optimal and most rational treatment for acute PMR, but carries high risks. At this point it is not entirely clear which patients are at highest risk. In this study we sought to determine in-hospital mortality and its predictors for patients who underwent mitral valve surgery for post-MI PMR. Between January 1990 and December 2012, 48 consecutive patients (mean age 64.9 ± 10.8 years) underwent mitral valve repair (n = 10) or replacement (n = 38) for post-MI PMR. Clinical data, echocardiographic data, catheterization data, and surgical reports were reviewed. Univariate and multivariate logistic regression analyses were performed to identify predictors of in-hospital mortality. Intraoperative mortality was 4.2% and in-hospital mortality was 25.0%. Univariate and multivariate logistic regression analyses revealed the logistic EuroSCORE and EuroSCORE II as independent predictors of in-hospital mortality. Receiver operating characteristics curves showed an optimal cutoff value of 40% for the logistic EuroSCORE (area under the curve 0.85, 95% CI 0.71-1.00, P < 0.001) and of 25% for the EuroSCORE II (area under the curve 0.83, 95% CI 0.68-0.99, P = 0.001). After removal of the EuroSCOREs from the model, complete PMR and intraoperative intra-aortic balloon pump (IABP) requirement were independent predictors of in-hospital mortality. The logistic EuroSCORE (optimal cutoff ≥ 40%), EuroSCORE II (optimal cutoff ≥ 25%), complete PMR, and intraoperative IABP requirement are strong independent predictors of in-hospital mortality in patients undergoing mitral valve surgery for post-MI PMR. These predictors may aid in surgical decision making and they may help improve the quality of informed consent.

  9. Intracranial Hypertension: Medication and Surgery

    MedlinePlus

    ... the atrium (heart). Many shunts used today have programmable valves, which means that the valves are externally adjustable. The advantage of a programmable valve is that after surgery, a physician can ...

  10. A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries

    NASA Astrophysics Data System (ADS)

    Lazebnik, Mariya; Popovic, Dijana; McCartney, Leah; Watkins, Cynthia B.; Lindstrom, Mary J.; Harter, Josephine; Sewall, Sarah; Ogilvie, Travis; Magliocco, Anthony; Breslin, Tara M.; Temple, Walley; Mew, Daphne; Booske, John H.; Okoniewski, Michal; Hagness, Susan C.

    2007-10-01

    The development of microwave breast cancer detection and treatment techniques has been driven by reports of substantial contrast in the dielectric properties of malignant and normal breast tissues. However, definitive knowledge of the dielectric properties of normal and diseased breast tissues at microwave frequencies has been limited by gaps and discrepancies across previously published studies. To address these issues, we conducted a large-scale study to experimentally determine the ultrawideband microwave dielectric properties of a variety of normal, malignant and benign breast tissues, measured from 0.5 to 20 GHz using a precision open-ended coaxial probe. Previously, we reported the dielectric properties of normal breast tissue samples obtained from reduction surgeries. Here, we report the dielectric properties of normal (adipose, glandular and fibroconnective), malignant (invasive and non-invasive ductal and lobular carcinomas) and benign (fibroadenomas and cysts) breast tissue samples obtained from cancer surgeries. We fit a one-pole Cole-Cole model to the complex permittivity data set of each characterized sample. Our analyses show that the contrast in the microwave-frequency dielectric properties between malignant and normal adipose-dominated tissues in the breast is considerable, as large as 10:1, while the contrast in the microwave-frequency dielectric properties between malignant and normal glandular/fibroconnective tissues in the breast is no more than about 10%.

  11. Percutaneous pulmonary valve implantation for free pulmonary regurgitation following conduit-free surgery of the right ventricular outflow tract.

    PubMed

    Cools, Bjorn; Brown, Stephen C; Heying, Ruth; Jansen, Katrijn; Boshoff, Derize E; Budts, Werner; Gewillig, Marc

    2015-01-01

    Pulmonary regurgitation (PR) following surgery of the right ventricular outflow tract (RVOT) is not innocent and leads to significant right heart dysfunction over time. Recent studies have demonstrated that percutaneous valves can be implanted in conduit free outflow tracts with good outcomes. To evaluate in patients with severe PR--anticipated to require future pulmonary valve replacement--the feasibility and safety of pre-stenting dilated non-stenotic patched conduit-free right ventricular outflow tracts before excessive dilation occurs, followed by percutaneous pulmonary valve implantation (PPVI). Twenty seven patients were evaluated, but only 23 were deemed suitable based on the presence of an adequate retention zone ≤ 24 mm defined by semi-compliant balloon interrogation of the RVOT. A 2 step procedure was performed: first the landing zone was prepared by deploying a bare stent, followed 2 months later by valve implantation. RVOT pre-stenting with an open cell bare metal stent (Andrastent XXL range) was performed at a median age of 13.0 years (range: 6.0-44.9) with a median weight of 44.3 kg (range: 20.0-88.0). Ninety six percent (22/23) of patients proceeded to PPVI a median of 2.4 months (range: 1.4-3.4) after initial pre-stent placement. Twenty one Melody valves and one 26 mm Edwards SAPIEN™ valve were implanted. Complications consisted of embolization of prestent (n = 1), scrunching (n = 4) and mild stent dislocation (n = 2). During follow-up, no stent fractures were observed and right ventricular dimensions decreased significantly. Post-surgical conduit-free non-stenotic RVOT with free pulmonary regurgitation can be treated percutaneously with a valved stent if anatomical (predominantly size) criteria are met. In experienced hands, the technique is feasible with low morbidity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Early and late outcomes of 1000 minimally invasive aortic valve operations.

    PubMed

    Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F

    2008-04-01

    Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.

  13. Recurrent prosthetic valve endocarditis caused by Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus)

    PubMed Central

    Uhrin, Gábor Balázs; Jensen, Rasmus Hare; Korup, Eva; Grønlund, Jens; Hjort, Ulla; Moser, Claus; Arendrup, Maiken Cavling; Schønheyder, Henrik Carl

    2015-01-01

    We report Aspergillus delacroxii (formerly Aspergillus nidulans var. echinulatus) causing recurrent prosthetic valve endocarditis. The fungus was the sole agent detected during replacement of a mechanical aortic valve conduit due to abscess formation. Despite extensive surgery and anti-fungal treatment, the patient had a cerebral hemorrhage 4 months post-surgery prompting a diagnosis of recurrent prosthetic valve endocarditis and fungemia. PMID:26909244

  14. Cardioscopic tricuspid valve repair in a beating ovine heart.

    PubMed

    Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y

    2009-04-01

    Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.

  15. [Intra-operative Acute Aortic Dissection during Aortic Root Reimplantation and Mitral Valve Reconstruction Surgery in a Patient with Marfan Syndrome;Report of a Case].

    PubMed

    Teramoto, Chikao; Kawaguchi, Osamu; Araki, Yoshimori; Yoshikawa, Masaharu; Uchida, Wataru; Takemura, Gennta; Makino, Naoki

    2016-08-01

    In patients with Marfan syndrome, cardiovascular complication due to aortic dissection represents the primary cause of death. Iatrogenic acute aortic dissection during cardiac surgery is a rare, but serious adverse event. A 51-year-old woman with Marfan syndrome underwent elective aortic surgery and mitral valve reconstruction surgery for the enlarged aortic root and severe mitral regurgitation. We replaced the aortic root and ascending aorta based on reimplantation technique. During subsequent mitral valve reconstruction, we found the heart pushed up from behind. Trans-esophageal echocardiography revealed a dissecting flap in the thoracic descending aorta. There was just weak signal of blood flow in the pseudolumen. We did not add any additional procedures such as an arch replacement. Cardio-pulmonary bypass was successfully discontinued. After protamine sulfate administration and blood transfusion, blood flow in the pseudolumen disappeared. The patient was successfully discharged from the hospital on 33th postoperative day without significant morbidities.

  16. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    PubMed

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  17. Aortic valve replacement with or without coronary artery bypass graft surgery: the risk of surgery in patients > or =80 years old.

    PubMed

    Maslow, Andrew; Casey, Paula; Poppas, Athena; Schwartz, Carl; Singh, Arun

    2010-02-01

    The purpose of this study was to evaluate the outcomes for elderly (> or =80 years) patients undergoing aortic valve replacement (AVR) with or without coronary artery bypass graft surgery (AVR/CABG). The authors hypothesized that the mortalities of AVR and AVR/CABG are lower than that predicted by published risk scores. A retrospective analysis of data from a single-hospital database. Single tertiary care, private practice. Consecutive patients undergoing AVR or AVR/CABG. Two hundred sixty-one elderly (> or =80 years) patients undergoing isolated AVR (145) or AVR/CABG (116) were evaluated. The majority (94.6%) underwent AVR for aortic valve stenosis. Outcomes were recorded and compared between the 2 surgical procedures with predicted mortalities based on published risk assessment scoring systems. The overall short-term mortality for the elderly group was 6.1% (AVR 5.5% and AVR/CABG 6.9%). The median long-term survival was 6.8 years. There were no significant differences in either morbidity or mortality between the AVR and AVR/CABG groups. Although predicted mortalities were similar for each surgical procedure, they overestimated observed outcome by up to 4-fold. Short- and long-term mortality was low for this group of elderly patients undergoing AVR or AVR/CABG and not significantly different between the 2 surgical groups. Predicted outcomes were worse than that observed, consistent with the hypothesis, and supportive of a more aggressive surgical treatment for aortic valve disease in the elderly patient. Copyright 2010 Elsevier Inc. All rights reserved.

  18. Left atrial volume index as a predictor for persistent left ventricular dysfunction after aortic valve surgery in patients with chronic aortic regurgitation: the role of early postoperative echocardiography.

    PubMed

    Cho, In-Jeong; Chang, Hyuk-Jae; Hong, Geu-Ru; Heo, Ran; Sung, Ji Min; Lee, Sang-Eun; Chang, Byung-Chul; Shim, Chi Young; Ha, Jong-Won; Chung, Namsik

    2015-06-01

    This study aimed to explore whether echocardiographic measurements during the early postoperative period can predict persistent left ventricular systolic dysfunction (LVSD) after aortic valve surgery in patients with chronic aortic regurgitation (AR). We prospectively recruited 54 patients (59 ± 12 years) with isolated chronic severe AR who subsequently underwent aortic valve surgery. Standard transthoracic echocardiography was performed before the operation, during the early postoperative period (≤2 weeks), and then 1 year after the surgery. Twelve patients with preoperative LVSD demonstrated LVSD at early after the surgery. Of the 42 patients without LVSD at preoperative echocardiography, 15 patients (36%) developed early postoperative LVSD after surgical correction. All 27 patients without LVSD at early postoperative echocardiography maintained LV function at 1 year after surgery. In the other 27 patients with postoperative LVSD, 17 patients recovered from LVSD and 10 patients did not at 1 year after surgery. Multiple logistic analysis demonstrated that postoperative left atrial volume index (LAVI) was the only independent predictor for persistent LVSD at 1 year after surgery in patients with postoperative LVSD (OR 1.180, 95% CI, 1.003-1.390, P = 0.046). The optimal LAVI cutoff value (>34.9 mL/m(2) ) had a sensitivity of 80% and a specificity of 88% for the prediction of persistent LVSD. Prevalence of early postoperative LVSD was relatively high, even in the patients without LVSD at preoperative echocardiography. Postoperative LAVI could be useful to predict persistent LVSD after aortic valve surgery in patients with early postoperative LVSD. © 2014, Wiley Periodicals, Inc.

  19. Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis.

    PubMed

    Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad

    2018-05-20

    Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.

  20. Mitral and tricuspid valve surgery in homozygous sickle cell disease: perioperative considerations for a successful outcome.

    PubMed

    Sachithanandan, Anand; Nanjaiah, Prakash; Wright, Christine J; Rooney, Stephen J

    2008-01-01

    Homozygous sickle cell disease (SCD) presents a multitude of challenges in patients undergoing cardiac surgery with cardiopulmonary bypass. Special consideration must be made in such patients and routine practice modified to prevent hypoxia, hypothermia, acidaemia and low-flow states which may potentially trigger a fatal sickling crisis perioperatively. We discuss several perioperative management strategies including a preoperative exchange transfusion, high flow normothermic bypass and warm blood cardioplegia that was utilized in a woman with homozygous SCD who underwent a successful double valve procedure.

  1. A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery.

    PubMed

    Leone, Alessandro; Bruno, Piergiorgio; Cammertoni, Federico; Massetti, Massimo

    2015-07-01

    Valve-sparing operations for the treatment of aortic root disease with a structurally normal aortic valve are increasingly performed as they avoid prosthesis-related complications. Short- and long-term results are critically dependent on perfect intraoperative restoration of valve anatomy and function. Residual aortic regurgitation is the main cause of early failure, and it is the most common motive for reoperation. However, intraoperative morphofunctional valve assessment requires expertise, and only transesophageal echocardiography can provide reliable information. We describe a simple, economic, reproducible hydrostatic test to intraoperatively evaluate valve competency under direct visualization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Intraluminal valves: development, function and disease

    PubMed Central

    Geng, Xin; Cha, Boksik; Mahamud, Md. Riaj

    2017-01-01

    ABSTRACT The circulatory system consists of the heart, blood vessels and lymphatic vessels, which function in parallel to provide nutrients and remove waste from the body. Vascular function depends on valves, which regulate unidirectional fluid flow against gravitational and pressure gradients. Severe valve disorders can cause mortality and some are associated with severe morbidity. Although cardiac valve defects can be treated by valve replacement surgery, no treatment is currently available for valve disorders of the veins and lymphatics. Thus, a better understanding of valves, their development and the progression of valve disease is warranted. In the past decade, molecules that are important for vascular function in humans have been identified, with mouse studies also providing new insights into valve formation and function. Intriguing similarities have recently emerged between the different types of valves concerning their molecular identity, architecture and development. Shear stress generated by fluid flow has also been shown to regulate endothelial cell identity in valves. Here, we review our current understanding of valve development with an emphasis on its mechanobiology and significance to human health, and highlight unanswered questions and translational opportunities. PMID:29125824

  3. Impact of the maze operation combined with left-sided valve surgery on the change in tricuspid regurgitation over time.

    PubMed

    Kim, Hyung-Kwan; Kim, Yong-Jin; Kim, Kwang-Il; Jo, Sang-Ho; Kim, Ki-Bong; Ahn, Hyuk; Sohn, Dae-Won; Oh, Byung-Hee; Lee, Myoung-Mook; Park, Young-Bae; Choi, Yun-Shik

    2005-08-30

    Atrial fibrillation (AF) has been reported to be a predisposing factor for the progression of TR in patients with previous mitral or combined mitral/aortic valve surgery. We hypothesized that the maze operation (MAZE) can prevent the progression of tricuspid regurgitation (TR) in these patients. We analyzed 170 patients (age, 45.5+/-10.9 years) who had undergone mitral or combined mitral/aortic valve surgery. On the basis of preoperative rhythm, patients were divided into 3 groups; GrI was composed of 44 patients with sinus rhythm, GrII of 48 who had undergone MAZE, and GrIII of 78 with AF who had not undergone MAZE. Echocardiographic examinations were performed before, immediately after, and 92.2+/-17.2 (range, 50 to 131) months after surgery. Preoperative and immediate postoperative clinical and echocardiographic parameters were similar among the groups. Insignificant TR at the immediate postoperative examination worsened with time in 7.3% of GrI (3 of 41), 12.8% of GrII (6 of 47), and 38.8% of GrIII (26 of 67) patients at the final examination (P=0.63 for GrI versus GrII, P=0.001 for GrI versus GrIII, P=0.005 for GrII versus GrIII). The incidence of significant TR at the final echocardiographic examination was higher in GrIII (39.7%) compared with GrI (9.1%) and GrII (14.6%) (P=0.001 for GrI versus GrIII, P=0.005 for GrII versus GrIII), whereas GrI and GrII did not show any difference (P=0.63). By multivariate analysis, the only factor identified to prevent TR progression was the group factor (GrI and GrII versus GrIII, P=0.002 and P=0.005, respectively). In a subgroup analysis of GrII according to the presence or absence of atrial mechanical activity, the absence of atrial mechanical activity was identified as an independent parameter for the progression of TR (P=0.001). AF predisposes patients undergoing mitral valve surgery to the progression of TR, which can be prevented by MAZE. This additional benefit of MAZE is largely dependent on the restoration and

  4. Perivalvular pannus and valve thrombosis: two concurrent mechanisms of mechanical valve prosthesis dysfunction.

    PubMed

    Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María

    2015-02-01

    A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  5. Aortic valve replacement using continuous suture technique in patients with aortic valve disease.

    PubMed

    Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku

    2013-08-01

    The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

  6. Minimally Invasive Mitral Valve Surgery III

    PubMed Central

    Lehr, Eric J.; Guy, T. Sloane; Smith, Robert L.; Grossi, Eugene A.; Shemin, Richard J.; Rodriguez, Evelio; Ailawadi, Gorav; Agnihotri, Arvind K.; Fayers, Trevor M.; Hargrove, W. Clark; Hummel, Brian W.; Khan, Junaid H.; Malaisrie, S. Chris; Mehall, John R.; Murphy, Douglas A.; Ryan, William H.; Salemi, Arash; Segurola, Romualdo J.; Smith, J. Michael; Wolfe, J. Alan; Weldner, Paul W.; Barnhart, Glenn R.; Goldman, Scott M.; Lewis, Clifton T. P.

    2016-01-01

    Abstract Minimally invasive mitral valve operations are increasingly common in the United States, but robotic-assisted approaches have not been widely adopted for a variety of reasons. This expert opinion reviews the state of the art and defines best practices, training, and techniques for developing a successful robotics program. PMID:27662478

  7. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].

    PubMed

    Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio

    2015-07-01

    A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.

  8. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.

    PubMed

    Reardon, Michael J; Van Mieghem, Nicolas M; Popma, Jeffrey J; Kleiman, Neal S; Søndergaard, Lars; Mumtaz, Mubashir; Adams, David H; Deeb, G Michael; Maini, Brijeshwar; Gada, Hemal; Chetcuti, Stanley; Gleason, Thomas; Heiser, John; Lange, Rüdiger; Merhi, William; Oh, Jae K; Olsen, Peter S; Piazza, Nicolo; Williams, Mathew; Windecker, Stephan; Yakubov, Steven J; Grube, Eberhard; Makkar, Raj; Lee, Joon S; Conte, John; Vang, Eric; Nguyen, Hang; Chang, Yanping; Mugglin, Andrew S; Serruys, Patrick W J C; Kappetein, Arie P

    2017-04-06

    Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number

  9. Bartonella and Coxiella infective endocarditis in Brazil: molecular evidence from excised valves from a cardiac surgery referral center in Rio de Janeiro, Brazil, 1998 to 2009.

    PubMed

    Lamas, Cristiane da Cruz; Ramos, Rosana Grandelle; Lopes, Gabriel Quintino; Santos, Marisa Silva; Golebiovski, Wilma Felix; Weksler, Clara; Ferraiuoli, Giovanna Ianini D'Almeida; Fournier, Pierre-Edouard; Lepidi, Hubert; Raoult, Didier

    2013-01-01

    PCR was used to detect Coxiella burnetii and Bartonella spp in heart valves obtained during the period 1998-2009 from patients operated on for blood culture-negative endocarditis in a cardiac surgery hospital in Brazil. Of the 51 valves tested, 10 were PCR-positive; two were positive for Bartonella and one for C. burnetii. Copyright © 2012 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Evolving Techniques for Mitral Valve Reconstruction

    PubMed Central

    Galloway, Aubrey C.; Grossi, Eugene A.; Bizekis, Costas S.; Ribakove, Greg; Ursomanno, Patricia; Delianides, Julie; Baumann, F. Gregory; Spencer, Frank C.; Colvin, Stephen B.

    2002-01-01

    Objective To analyze the effectiveness of new techniques of mitral valve reconstruction (MVR) that have evolved over the last decade, such as aggressive anterior leaflet repair and minimally invasive surgery using an endoaortic balloon occluder. Summary Background Data MVR via conventional sternotomy has been an established treatment for mitral insufficiency for over 20 years, primarily for the treatment of patients with posterior leaflet prolapse. Methods Between June 1980 and June 2001, 1,195 consecutive patients had MVR with ring annuloplasty. Conventional sternotomy was used in 843 patients, minimally invasive surgery in 352 (since June 1996). Anterior leaflet repair was performed in 374 patients, with increasing use over the last 10 years. Follow-up was 100% complete (mean 4.6 years, range 0.5–20.5). Results Hospital mortality was 4.7% overall and 1.4% for isolated MVR (1.1% for minimally invasive surgery vs. 1.6% for conventional sternotomy;P = .4). Multivariate analysis showed the factors predictive of increased operative risk to be age, NYHA functional class, concomitant procedures, and previous cardiac surgery. The 5-year results for freedom from cardiac death, reoperation, and valve-related complications among the 782 patients with degenerative etiology are, respectively, as follows (P > .05 for all end points): for anterior leaflet repair, 93%, 94%, 90%; for no anterior leaflet repair, 91%, 92%, 91%; for minimally invasive surgery, 97%, 89%, 93%; and for conventional sternotomy, 93%, 94%, 90%. Conclusions These findings indicate that late results of MVR after minimally invasive surgery and after anterior leaflet repair are equivalent to those achievable with conventional sternotomy and posterior leaflet repair. These options significantly expand the range of patients suitable for mitral valve repair surgery and give further evidence to support wider use of minimally invasive techniques. PMID:12192315

  11. Pediatric heart surgery

    MedlinePlus

    Heart surgery - pediatric; Heart surgery for children; Acquired heart disease; Heart valve surgery - children ... There are many kinds of heart defects. Some are minor, and others are more serious. Defects can occur inside the heart or in the large blood vessels ...

  12. Pediatric heart surgery - discharge

    MedlinePlus

    ... of the aorta repair - discharge; Heart surgery for children - discharge; Atrial septal defect repair - discharge; Ventricular septal ... discharge; Acquired heart disease - discharge; Heart valve surgery - ... Heart surgery - pediatric - discharge; Heart transplant - pediatric - ...

  13. Male-female differences and survival in patients undergoing isolated mitral valve surgery: a nationwide cohort study in the Netherlands.

    PubMed

    Mokhles, Mostafa M; Siregar, Sabrina; Versteegh, Michel I M; Noyez, Luc; van Putte, Bart; Vonk, Alexander B A; Roos-Hesselink, Jolien W; Bogers, Ad J J C; Takkenberg, Johanna J M

    2016-09-01

    The objective of this study was to compare male-female differences with respect to baseline characteristics and short-term outcome in a contemporary nationwide cohort of patients who underwent isolated mitral valve (MV) surgery. All patients [N = 3411; 58% males (N = 1977)] who underwent isolated MV surgery (replacement: N = 1048, 31%; reconstruction: N = 2364, 69%) in the Netherlands between January 2007 and December 2011 were included in this study. Differences in patient and procedural characteristics and in-hospital outcome were compared between male and female patients. Female patients were generally older (mean age, 64 vs 61 years, P < 0.001), presented more often with pulmonary hypertension (P = 0.03) and had higher logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) I (P < 0.001). Male patients presented more often with prior coronary artery bypass graft surgery (P < 0.001) and active endocarditis (P = 0.002). Female patients underwent MV replacement more often (P < 0.001) and, in case of replacement, received stented bioprostheses more often (P < 0.001). In-hospital mortality rates after MV replacement were 7% (n = 33) and 7% (n = 40) in male and female patients, respectively (OR 1.08, 95% CI 0.67-1.75; P = 0.75). In-hospital mortality rates after MV reconstruction were 1.4% (n = 21) and 1.3% (n = 11) in male and female patients, respectively (OR 0.88, 95% CI 0.42-1.84; P = 0.74). There are substantial male-female differences in patient presentation and procedural aspects in isolated MV surgery in the Netherlands. Female patients are older, have more severe disease at the time of surgery and undergo valve repair less often. Future studies are needed to identify potentially modifiable patient factors to improve the outcome of female patients with MV disease. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. The association between the transfusion of small volumes of leucocyte-depleted red blood cells and outcomes in patients undergoing open-heart valve surgery.

    PubMed

    Zittermann, Armin; Koster, Andreas; Faraoni, David; Börgermann, Jochen; Schirmer, Uwe; Gummert, Jan F

    2017-02-01

    The relationship between the transfusion of red blood cell (RBC) units and outcomes in patients undergoing cardiac surgery is the subject of intense debates. In this study, we investigated the relationship between the transfusion of 1-2 leucocyte-depleted (LD) RBC units and outcomes in patients undergoing open-heart valve surgery. The investigation encompassed consecutive patients undergoing open-heart valve surgery at our institution between July 2009 and March 2015 who received no (RBC- group) or 1-2 units of LD RBC (RBC+ group). End-points were 30-day mortality (primary), the incidence of in-hospital major organ dysfunctions and 1-year mortality (secondary). Propensity score (PS)-adjusted statistical analysis was used to assess the effect of RBC transfusion on end-points. Thirty-day mortality rate was 0.2% (3/1485) in the RBC- group and 0.4% (6/1672) in the RBC+ group, with a PS-adjusted odds ratio (OR) for 30-day mortality of 1.00 (95% CI: 0.21-4.83;P = 0.99). The two groups showed no significant differences in PS-adjusted ORs for major complications, such as stroke, low cardiac output syndrome, thoracic wound infection and prolonged mechanical ventilation (>24 h). The PS-adjusted ORs for prolonged intensive care unit stay (>48 h) were, however, significantly higher in the RBC+ group (OR = 1.34 [95%CI: 1.04-1.72; P = 0.02]) than in the RBC- group. One-year mortality was comparable between groups (PS-adjusted hazard ratio for the RBC+ group: 0.85 [95% CI: 0.42-1.72; P = 0.65]). Our data do not provide evidence that in patients undergoing valve surgery with cardiopulmonary bypass, transfusion of 1-2 units of LD RBC increases operative mortality, the incidence of postoperative complications or 1-year mortality. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Minimally Invasive Aortic Valve Replacement Following Root Enlargement on too Narrow Annulus to Perform Transcatheter Aortic Valve Implantation.

    PubMed

    Sakamoto, Kosuke; Totsugawa, Toshinori; Hiraoka, Arudo; Tamura, Kentaro; Yoshitaka, Hidenori; Sakaguchi, Taichi

    2018-05-30

    An 88-year-old woman was diagnosed with aortic stenosis and an aortic annulus that was too narrow to perform transcatheter aortic valve implantation. Surgery was performed through a 7-cm right mini-thoracotomy at the fourth intercostal space. A 19-mm aortic valve bioprosthesis was implanted after root enlargement. The fourth intercostal space was a suitable site for aortic root enlargement because of the shorter skin-to-root distance and the detailed exposure of the aortic valve after cutting the aortic wall. This study concluded that minimally-invasive aortic valve replacement following root enlargement can be an option for the treatment of elderly patients with aortic stenosis accompanied by an annulus that is too small to perform transcatheter aortic valve implantation.

  16. Magnetic resonance imaging for cerebral lesions during minimal invasive mitral valve surgery: study protocol for a randomized controlled trial.

    PubMed

    Barbero, Cristina; Ricci, Davide; Cura Stura, Erik; Pellegrini, Augusto; Marchetto, Giovanni; ElQarra, Suad; Boffini, Massimo; Passera, Roberto; Valentini, Maria Consuelo; Rinaldi, Mauro

    2017-02-21

    Recent data have highlighted a higher rate of neurological injuries in minimal invasive mitral valve surgery (MIMVS) compared with the standard sternotomy approach; therefore, the role of specific clamping techniques and perfusion strategies on the occurrence of this complication is a matter of discussion in the medical literature. The purpose of this trial is to prospectively evaluate major, minor and silent neurological events in patients undergoing right mini-thoracotomy mitral valve surgery using retrograde perfusion and an endoaortic clamp or a transthoracic clamp. A prospective, blinded, randomized controlled study on the rate of neurological embolizations during MIMVS started at the University of Turin in June 2014. Major, minor and silent neurological events are being investigated through standard neurological evaluation and magnetic resonance imaging assessment. The magnetic resonance imaging protocol includes conventional sequences for the morphological and quantitative assessment and nonconventional sequences for the white matter microstructural evaluation. Imaging studies are performed before surgery as baseline assessment and on the third postoperative day and, in patients who develop postoperative ischemic lesions, after 6 months. Despite recent concerns raised about the endoaortic setting with retrograde perfusion, we expect to show equivalence in terms of neurological events of this technique compared with the transthoracic clamp in a selected cohort of patients. With the first results expected in December 2016 the findings would be of help in confirming the efficacy and safety of MIMVS. ClinicalTrials.gov, Identifier: NCT02818166 . Registered on 8 February 2016 - trial retrospectively registered.

  17. Apixaban Versus Warfarin for Mechanical Heart Valve Thromboprophylaxis in a Swine Aortic Heterotopic Valve Model.

    PubMed

    Lester, Patrick A; Coleman, Dawn M; Diaz, Jose A; Jackson, Tatum O; Hawley, Angela E; Mathues, Angela R; Grant, Brandon T; Knabb, Robert M; Ramacciotti, Eduardo; Frost, Charles E; Song, Yan; Wakefield, Thomas W; Myers, Daniel D

    2017-05-01

    Warfarin is the current standard for oral anticoagulation therapy in patients with mechanical heart valves, yet optimal therapy to maximize anticoagulation and minimize bleeding complications requires routine coagulation monitoring, possible dietary restrictions, and drug interaction monitoring. As alternatives to warfarin, oral direct acting factor Xa inhibitors are currently approved for the prophylaxis and treatment of venous thromboembolism and reduction of stroke and systemic embolization. However, no in vivo preclinical or clinical studies have been performed directly comparing oral factor Xa inhibitors such as apixaban to warfarin, the current standard of therapy. A well-documented heterotopic aortic valve porcine model was used to test the hypothesis that apixaban has comparable efficacy to warfarin for thromboprophylaxis of mechanical heart valves. Sixteen swine were implanted with a bileaflet mechanical aortic valve that bypassed the ligated descending thoracic aorta. Animals were randomized to 4 groups: control (no anticoagulation; n=4), apixaban oral 1 mg/kg twice a day (n=5), warfarin oral 0.04 to 0.08 mg/kg daily (international normalized ratio 2-3; n=3), and apixaban infusion (n=4). Postmortem valve thrombus was measured 30 days post-surgery for control-oral groups and 14 days post-surgery for the apixaban infusion group. Control thrombus weight (mean) was significantly different (1422.9 mg) compared with apixaban oral (357.5 mg), warfarin (247.1 mg), and apixiban 14-day infusion (61.1 mg; P <0.05). Apixaban is a promising candidate and may be a useful alternative to warfarin for thromboprophylaxis of mechanical heart valves. Unlike warfarin, no adverse bleeding events were observed in any apixaban groups. © 2017 American Heart Association, Inc.

  18. Surgery Videos: MedlinePlus

    MedlinePlus Videos and Cool Tools

    ... 2009) Mitral Valve Prolapse Minimally Invasive Heart Surgery: Robot Assisted Mitral Valve Repair (Baptist Health South Florida, ... Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission Medical ...

  19. Fibrinolytic therapy for mechanical pulmonary valve thrombosis.

    PubMed

    Khajali, Zahra; Mohammadzadeh, Shabnam; Maleki, Majid; Peighambari, Mohammad Mehdi; Sadeghpoor, Anita; Ghavidel, Alireza; Elahi, Behrad; Mirzaaghayan, Mohammadreza

    2015-01-01

    Treatment of prosthetic heart valve thrombosis using intravenous thrombolytics, although an acceptable alternative to surgery, is not complication free, and the literature has a dearth of data on the subject. This study analyzed the results of fibrinolytic treatment (FT) among a single-center group of patients with mechanical pulmonary valve thrombosis. Between 2000 and 2013, 23 consecutive patients with 25 episodes of pulmonary valve thrombosis received FT. The diagnosis of mechanical pulmonary valve thrombosis was established by fluoroscopy and echocardiography. Streptokinase (SK) was used in 24 cases and alteplase in 1 case. The FT was continued a second day for 14 patients (58.3%), a third day for 1 patient, and a fourth day for 1 patient. Echocardiography and fluoroscopy were performed every day until improvement of malfunction was achieved. Of the 23 patients, 19 had complete resolution of hemodynamic abnormalities after FT, 1 had partial resolution, and 2 showed no change. No patient had major complications. Five minor complications were detected, namely, fever, nausea, thrombophlebitis, epistaxi, and pain. Seven patients (30%) experienced recurrence of thrombosis, whereas four patients had surgery (biological pulmonary valve replacement) without re-thrombolytic therapy, one patient was treated with Alteplase, one patient received SK, and one patient received intense anticoagulation using heparin and warfarin. Overall, FT had a success rate of 84%. The results indicate that regardless of the time to pulmonary valve replacement and echocardiographic and fluoroscopic findings, FT was effective in most cases of mechanical pulmonary valve thrombosis. The efficacy increased with second-day thrombolytic therapy. Major complications were not common after lytic therapy for mechanical pulmonary valve thrombosis.

  20. Indication for percutaneous aortic valve implantation

    PubMed Central

    Akin, Ibrahim; Kische, Stephan; Rehders, Tim C.; Nienaber, Christoph A.; Rauchhaus, Mathias; Schneider, Henrik; Liebold, Andreas

    2010-01-01

    The incidence of valvular aortic stenosis has increased over the past decades due to improved life expectancy. Surgical aortic valve replacement is currently the only treatment option for severe symptomatic aortic stenosis that has been shown to improve survival. However, up to one third of patients who require lifesaving surgical aortic valve replacement are denied surgery due to high comorbidities resulting in a higher operative mortality rate. In the past such patients could only be treated with medical therapy or percutaneous aortic valvuloplasty, neither of which has been shown to improve mortality. With advances in interventional cardiology, transcatheter methods have been developed for aortic valve replacement with the goal of offering a therapeutic solution for patients who are unfit for surgical therapy. Currently there are two catheter-based treatment systems in clinical application (the Edwards SAPIEN aortic valve and the CoreValve ReValving System), utilizing either a balloon-expandable or a self-expanding stent platform, respectively. PMID:22371763

  1. Transcatheter aortic valve implantation and off-pump coronary artery bypass surgery: an effective hybrid procedure in selected patients.

    PubMed

    Mayr, Benedikt; Firschke, Christian; Erlebach, Magdalena; Bleiziffer, Sabine; Krane, Markus; Joner, Michael; Herold, Ulf; Nöbauer, Christian; Lange, Rüdiger; Deutsch, Marcus-André

    2018-02-26

    Simultaneous surgical off-pump coronary revascularization and transcatheter aortic valve implantation (TAVI) as a hybrid procedure may be a therapeutic option for patients with a TAVI indication who are not suitable for percutaneous coronary intervention and for patients who have an indication for combined surgical aortic valve implantation and coronary artery bypass grafting but present with a porcelain aorta. Early outcomes of these patients are analysed in this study. From February 2011 to April 2017, hybrid TAVI/off-pump coronary artery bypass (OPCAB) was performed in 12 (60%) patients, hybrid TAVI/minimally invasive direct coronary artery bypass in 6 (30%) patients and staged TAVI/OPCAB in 2 (10%) patients. Endpoints of this study were 30-day mortality, device success and postoperative adverse events as defined by the updated Valve Academic Research Consortium (VARC-2). The median age at the time of surgery was 77 years [interquartile range (IQR), 70-81] with a median logistic EuroSCORE and Society of Thoracic Surgeons' Predicted Risk score of 16.1% (IQR, 9.3-28.1) and 3.9% (IQR, 2.2-5.6), respectively. The median Synergy between PCI with Taxus and Cardiac Surgery score was 16.5 (IQR, 9.8-22.8). TAVI implantation routes were transaortic in 9 (45%) patients, transapical and transfemoral in 5 (25%) patients each and transsubclavian in 1 (5%) patient. Complete myocardial revascularization was achieved in 75% of patients. Device success rate was 100%. Paravalvular aortic regurgitation did not exceed mild in any patient. Stroke/transient ischaemic attack, vascular complications and myocardial infarction were not observed. Re-exploration for bleeding was required in 1 (5%) patient. Thirty-day mortality was 0%. Hybrid OPCAB/MIDCAB and TAVI prove to be a safe and effective alternative treatment option in selected higher risk patients.

  2. Remote microwave monitoring of magnetization switching in CoFeB/Ta/CoFeB spin logic device

    NASA Astrophysics Data System (ADS)

    Morgunov, R.; L'vova, G.; Talantsev, A.; Koplak, O.; Petit-Watelot, S.; Devaux, X.; Migot, S.; Lu, Y.; Mangin, S.

    2017-05-01

    Stable magnetic states of the MgO/CoFeB/Ta/CoFeB/MgO/Ta spin valve as well as transitions between the states were detected by microwave magnetoresistance (MMR) measured in the cavity of an electron spin resonance spectrometer. Advantages of this experimental technique are the possibility to study the orientation dependence of the MMR, the absence of the additional contact/sample interfaces, the wireless control of the spin valves, and the compatibility of the MMR measurements with ferromagnetic resonance experiments. The magnetic field dependence of the first derivation of the microwave absorption allows one to judge about the negative magnetoresistance of the layers and positive interlayer giant magnetoresistance. The obtained experimental results could be used for engineering of the microwave high sensitive sensors available for remote identification of the stable magnetic and logic states of the spin valves needful in medical spintronics to detect biological objects labeled with nanoparticles.

  3. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    PubMed

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Influence of impairment in renal function on the accuracy of high-sensitivity cardiac troponin T for the diagnosis of perioperative myocardial infarction after heart valve surgery.

    PubMed

    Cubero-Gallego, Hector; Heredia-Rodriguez, Maria; Tamayo, Eduardo

    2018-03-12

    We aimed to assess the influence of impairment in renal function over the high-sensitivity cardiac troponin T (hs-cTnT) accuracy to diagnose perioperative myocardial infarction (MI) after heart valve surgery. Heart valve surgery was performed in 805 patients from June 2012 to January 2016. Patients with enzymatic curves of hs-cTnT suggestive of myocardial necrosis and electrocardiogram and/or transthoracic echocardiogram criteria were identified as patients with perioperative MI. Impairment in renal function was defined as a postoperative creatinine clearance <50 ml/min at 16 h after surgery and for at least 48 h. Patients included were divided into 2 groups at 16 h: (i) patients with normal renal function (creatinine clearance >50 ml/min) and (ii) patients with impairment in renal function (creatinine clearance <50 ml/min). From a total of 805 patients undergoing heart valve surgery, 88 patients developed perioperative MI. When comparing receiver operating characteristic curves in patients with perioperative MI according to renal function, the optimal threshold of hs-cTnT at 16 h differed in patients with impairment in renal function (1303 vs 1095 pg/ml, P < 0.001). The diagnostic accuracy of hs-cTnT at 16 h was 93.4% [95% confidence interval (CI) 89.98-96.86], with an area under receiver operating characteristic curve (0.993, 95% CI 0.988-0.999 vs 0.972, 95% CI 0.952-0.992; P < 0.001). Renal function might influence in hs-cTnT levels. However, a hs-cTnT threshold of 1303 pg/ml at 16 h may be applied according to renal function to diagnose perioperative MI after cardiac surgery.

  5. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    PubMed

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  6. Dysfunction of an On-X Heart Valve by Pannus.

    PubMed

    Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria

    2016-09-01

    A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.

  7. Aortic valve ochronosis: a rare manifestation of alkaptonuria

    PubMed Central

    Steger, Christina Maria

    2011-01-01

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed. PMID:22689837

  8. Aortic valve ochronosis: a rare manifestation of alkaptonuria.

    PubMed

    Steger, Christina Maria

    2011-07-28

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.

  9. Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis.

    PubMed

    Wijesinghe, Namal; Ye, Jian; Rodés-Cabau, Josep; Cheung, Anson; Velianou, James L; Natarajan, Madhu K; Dumont, Eric; Nietlispach, Fabian; Gurvitch, Ronen; Wood, David A; Tay, Edgar; Webb, John G

    2010-11-01

    We evaluated transcatheter aortic valve implantation (TAVI) in high-risk patients with bicuspid aortic valve (BAV) stenosis. TAVI shows promise in the treatment of severe stenosis of triscupid aortic valves, especially in high-risk patients. However, BAV stenosis has been considered a contraindication to TAVI. Eleven patients (age 52 to 90 years) with symptomatic severe BAV stenosis underwent TAVI at 3 Canadian tertiary hospitals between May 2006 and April 2010. All patients were considered high risk for surgical aortic valve replacement. Edwards-SAPIEN transcatheter heart valves (Edwards Lifesciences, Inc., Irvine, California) were used. Transfemoral or transapical access was selected, depending on the adequacy of femoral access. Access was transfemoral in 7 patients and transapical in 4 patients. There were no intraprocedural complications. Significant symptomatic and hemodynamic improvement was observed in 10 of 11 patients. Baseline aortic valve area of 0.65 ± 0.17 cm(2) and mean transaortic pressure gradient of 41 ± 22.4 mm Hg were improved to 1.45 ± 0.3 cm(2) and 13.4 ± 5.7 mm Hg, respectively. Two patients had moderate perivalvular leaks. At the 30-day follow-up there were 2 deaths due to multisystem failure in 2 transapical patients. In 1 patient an undersized, suboptimally positioned, unstable valve required late conversion to open surgery. TAVI in selected high-risk patients with severe BAV stenosis can be successfully performed with acceptable clinical outcomes but will require further evaluation. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Open heart surgery after renal transplantation.

    PubMed

    Yamamura, Mitsuhiro; Miyamoto, Yuji; Mitsuno, Masataka; Tanaka, Hiroe; Ryomoto, Masaaki; Fukui, Shinya; Tsujiya, Noriko; Kajiyama, Tetsuya; Nojima, Michio

    2014-09-01

    to evaluate the strategy for open heart surgery after renal transplantation performed in a single institution in Japan. we reviewed 6 open heart surgeries after renal transplantation in 5 patients, performed between January 1992 and December 2012. The patients were 3 men and 2 women with a mean age of 60 ± 11 years (range 46-68 years). They had old myocardial infarction and unstable angina, aortic and mitral stenosis, left arterial myxoma, aortic stenosis, and native valve endocarditis followed by prosthetic valve endocarditis. Operative procedures included coronary artery bypass grafting, double-valve replacement, resection of left arterial myxoma, 2 aortic valve replacements, and a double-valve replacement. Renal protection consisted of steroid cover (hydrocortisone 100-500 mg or methylprednisolone 1000 mg) and intravenous immunosuppressant infusion (cyclosporine 30-40 mg day(-1) or tacrolimus 1.0 mg day(-1)). 5 cases were uneventful and good renal graft function was maintained at discharge (serum creatinine 2.1 ± 0.5 mg dL(-1)). There was one operative death after emergency double-valve replacement for methicillin-resistant Staphylococcus aureus-associated prosthetic valve endocarditis. Although the endocarditis improved after valve replacement, the patient died of postoperative pneumonia on postoperative day 45. careful perioperative management can allow successful open heart surgery after renal transplantation. However, severe complications, especially methicillin-resistant Staphylococcus aureus infection, may cause renal graft loss. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Aortic valve surgery of the 21st century: sutureless AVR versus TAVI.

    PubMed

    Costache, Victor S; Moldovan, Horatiu; Arsenescu, Catalina; Costache, Andreea

    2018-04-01

    Surgical aortic valve replacement (sAVR) has been a safe, effective and time-proven technique and is still the standard of care all over the world for aortic valve treatment. The vast majority of centers perform this procedure by doing a median sternotomy with several disadvantages. While many others specialties went minimally invasive decades ago, in cardiovascular field transcatheter valve implantation was the first minimally invasive valvular procedure that gained rapid worldwide acceptance. Transcatheter valve replacement (TAVR) is now marketed as a procedure that should be performed under local anesthesia, by an interventional cardiologist via trans femoral route with no other healthcare professional invited to the patient selection or case planning. An increasing number of surgeons are promoting minimally invasive aortic valve replacement, which is gaining grounds, especially with the help of the new sutureless valve technology. With these two new technologies emerging, legitimate questions arise and need to be answered - which has the longest durability, lower complication rate and lower overall mortality.

  12. Comparison of the CoaguChek XS handheld coagulation analyzer and conventional laboratory methods measuring international normalised ratio (INR) values during the time to therapeutic range after mechanical valve surgery.

    PubMed

    Bardakci, Hasmet; Altıntaş, Garip; Çiçek, Omer Faruk; Kervan, Umit; Yilmaz, Sevinc; Kaplan, Sadi; Birincioglu, Cemal Levent

    2013-05-01

    To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.

  13. Mitral Valve Clip for Treatment of Mitral Regurgitation: An Evidence-Based Analysis

    PubMed Central

    Ansari, Mohammed T.; Ahmadzai, Nadera; Coyle, Kathryn; Coyle, Doug; Moher, David

    2015-01-01

    Background Many of the 500,000 North American patients with chronic mitral regurgitation may be poor candidates for mitral valve surgery. Objective The objective of this study was to investigate the comparative effectiveness, harms, and cost-effectiveness of percutaneous mitral valve repair using mitral valve clips in candidates at prohibitive risk for surgery. Data Sources We searched articles in MEDLINE, Embase, and the Cochrane Library published from 1994 to February 2014 for evidence of effectiveness and harms; for economic literature we also searched NHS EED and Tufts CEA registry. Grey literature was also searched. Review Methods Primary studies were sought from existing systematic reviews that had employed reliable search and screening methods. Newer studies were sought by searching the period subsequent to the last search date of the review. Two reviewers screened records and assessed study validity. We used the Cochrane risk of bias tool for randomized, generic assessment for non-randomized studies, and the Phillips checklist for economic studies. Results Ten studies including 1 randomized trial were included. The majority of the direct comparative evidence compared the mitral valve clip repair with surgery in patients not particularly at prohibitive surgical risk. Irrespective of degenerative or functional chronic mitral regurgitation etiology, evidence of effectiveness and harms is inconclusive and of very low quality. Very-low-quality evidence indicates that percutaneous mitral valve clip repair may provide a survival advantage, at least during the first 1 to 2 years, particularly in medically managed chronic functional mitral regurgitation. Because of limitations in the design of studies, the cost-effectiveness of mitral valve clips in patients at prohibitive risk for surgery also could not be established. Limitations Because of serious concerns of risk of bias, indirectness, and imprecision, evidence is of very low quality. Conclusions No meaningful

  14. Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads.

    PubMed

    Uehara, Kyokun; Minakata, Kenji; Watanabe, Kentaro; Sakaguchi, Hisashi; Yamazaki, Kazuhiro; Ikeda, Tadashi; Sakata, Ryuzo

    2016-07-01

    Tricuspid valve regurgitation due to pacemaker leads is a well-known complication. Although some reports have suggested that pacemaker leads should be surgically explanted, strongly adhered leads cannot always be removed. The aim of this study was to describe our tricuspid valve repair techniques with pacemaker leads left in situ. Our retrospective study investigated 6 consecutive patients who required tricuspid valve surgery for severe regurgitation induced by pacemaker leads. From the operative findings, we identified 3 patterns of tricuspid valve and pacemaker lead involvement. In 3 patients, the leads were caught in the chordae, in 2 patients, tricuspid regurgitation was caused by lead impingement on the septal leaflet, and in 3 patients, tricuspid valve leaflets had been perforated by the pacemaker leads. During surgery, all leads were left in situ after being separated from the leaflet or valvular apparatus. In addition, suture annuloplasty was performed for annular dilatation in all cases. In one patient, the lead was reaffixed to the annulus after the posterior leaflet was cut back towards the annulus, and the leaflet was then closed. There was one hospital death due to sepsis. The degree of tricuspid regurgitation was trivial in all surviving patients at discharge. During a mean follow-up of 21 months, one patient died from pneumonia 20 months after tricuspid valve repair. In patients undergoing tricuspid valve surgery due to severe tricuspid regurgitation caused by pacemaker leads, the leads can be left in situ after proper repair with annuloplasty. © The Author(s) 2016.

  15. Quality and Safety in Health Care, Part XXIX: The Transcatheter Valve Therapy Registry.

    PubMed

    Harolds, Jay A

    2017-11-01

    The American College of Cardiology, the Society of Thoracic Surgeons, and other organizations cooperated to form the Transcatheter Valve Therapy Registry. This registry studies information on the outcome of valve therapy device placement with a transcatheter approach. The companies that manufacture these devices can use the registry to meet the post-product sale surveillance requirements of the US Food and Drug Administration. There will also be linkage to the registry information from the Society of Thoracic Surgeons Adult Cardiac Surgery Database, which has information on open cardiac valve surgery.

  16. Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk

    PubMed Central

    Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E.

    2015-01-01

    Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient. PMID:26346128

  17. Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk.

    PubMed

    Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E

    2015-01-01

    Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient.

  18. Multiplanar visualization in 3D transthoracic echocardiography for precise delineation of mitral valve pathology.

    PubMed

    Kuppahally, Suman S; Paloma, Allan; Craig Miller, D; Schnittger, Ingela; Liang, David

    2008-01-01

    A novel multiplanar reformatting (MPR) technique in three-dimensional transthoracic echocardiography (3D TTE) was used to precisely localize the prolapsed lateral segment of posterior mitral valve leaflet in a patient symptomatic with mitral valve prolapse (MVP) and moderate mitral regurgitation (MR) before undergoing mitral valve repair surgery. Transesophageal echocardiography was avoided based on the findings of this new technique by 3D TTE. It was noninvasive, quick, reproducible and reliable. Also, it did not need the time-consuming reconstruction of multiple cardiac images. Mitral valve repair surgery was subsequently performed based on the MPR findings and corroborated the findings from the MPR examination.

  19. Transapical aortic valve implantation and minimally invasive off-pump bypass surgery

    PubMed Central

    Ahad, Samir; Baumbach, Hardy; Hill, Stephan; Franke, Ulrich F. W.

    2014-01-01

    Transcatheter aortic valve implantation (TAVI) has gained increasing popularity for high-risk patients with symptomatic aortic valve stenosis. A concomitant coronary artery disease leads to a complicated management and an increased perioperative risk. This case report describes the successful total arterial coronary revascularization of the left anterior descending and the left marginal branch of the circumflex artery utilizing the left internal mammary artery (LIMA) and left radial artery in off-pump technique in combination with the transapical transcatheter aortic valve implantation via minimally invasive anterolateral access in the fifth intercostal space. PMID:24221960

  20. Understanding Heart Valve Problems and Causes

    MedlinePlus

    ... and conditions that can cause valve problems: Infective endocarditis Injury Rheumatic fever These conditions can cause one ... Surgery? Recovery Milestones Checklist | Spanish What Is Infective Endocarditis? | Spanish Interactive Treatment Guide Infographic: What Everyone Should ...

  1. Heart Valve Surgery Recovery and Follow Up

    MedlinePlus

    ... Winning Recovery Plan Post Surgery Milestones • Personal Stories Video: Preparing For Your Surgery Find helpful tips from ... how to plan and prepare for your surgery. Video: Recovering From Your Surgery Find helpful tips from ...

  2. Intravitreal ranibizumab injection combined trabeculectomy versus Ahmed valve surgery in the treatment of neovascular glaucoma: assessment of efficacy and complications.

    PubMed

    Liu, Lan; Xu, Yongfeng; Huang, Zhu; Wang, Xiaoyu

    2016-05-26

    Researches have shown anti-vascular endothelial growth factor (VEGF) agent is effective in treating neovascular eye diseases. The purpose of this study is to evaluate the efficacy and safety of intravitreal ranibizumab (IVR) injection combined trabeculectomy in the treatment of neovascular glaucoma (NVG), and compared it with Ahmed valve surgery. Thirty-six NVG patients (37 eyes) from the First Affiliated Hospital of Zhejiang medical college, between January 1, 2014 and January 31, 2015, were included in this prospective, interventional clinical study. Eighteen NVG eyes were given IVR injection one week before trabeculectomy. Ahmed valve implantation surgery was performed in nineteen eyes. Ocular pain, best corrected visual acuity (BCVA), intraocular pressure (IOP) and surgical complications were evaluated before and after the surgery. IOP was significantly decreased following IVR injection combined trabeculectomy treatment (baseline 57.1 ± 8.9 mmHg; week 1, 15.2 ± 4.3 mmHg p = 0.000; month 1, 16.9 ± 2.1 mmHg p = 0.000; month 3, 20.3 ± 7.7 mmHg p = 0.000; month 6, 19.7 ± 7.3 mmHg p = 0.000). There was a significant, though modest, BCVA improvement in sighted eyes of IVR group (baseline 2.42 ± 0.68, W1 1.80 ± 0.91, P = 0.013; M1 1.77 ± 0.93, p = 0.011). IVR injection combined trabeculectomy had less postoperative complications and lower failure ratio than Ahmed surgery (IVR 5.6 %, Ahmed 31.6 %). The study revealed that IVR injection combined trabeculectomy was an effective and safe treatment for NVG. Compared with Ahmed surgery, IVR injection combined trabeculectomy had less complications and higher success ratio. (Chinese Clinical Registry, TRN ChiCTR-OPN-16008147, 3/24/2016, retrospectively registered).

  3. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.

    PubMed

    Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  4. The value of aortic valve replacement in elderly patients: an economic analysis.

    PubMed

    Wu, YingXing; Grunkemeier, Gary L; Starr, Albert

    2007-03-01

    Economists have designed frameworks to measure the economic value of improvements in health and longevity. Heart valve replacement surgery has significantly prolonged life expectancy and quality of life. For the example of aortic valve replacement, what is its economic value according to this framework? From 1961 through 2003, a total of 4617 adult patients underwent aortic valve replacement by one team of cardiac surgeons. These patients were provided with a prospective lifetime follow-up service. As of 2005, observed follow-up was 31,671 patient-years, with a maximum of 41 years. A statistical model was used to generate the future life-years of patients currently alive. The value of life-years proposed by economists was applied to determine the economic value of the additional life given to these patients by aortic valve replacement. The total life-years after aortic valve replacement were 53,323, with a gross value of 14.6 billion dollars. The total expected life-years without surgery were 10,157, with an estimated value of 3.0 billion dollars. Thus the net life-years gained by AVR were 43,166, worth 11.6 billion dollars. Subtracting the 451 million dollars total lifetime cost of surgery, the net value of the life-years gained by AVR was 11.2 billion dollars. The mean net value decreases according to age at surgery but is still worth 600,000 dollars for octogenarians and 200,000 dollars for nonagenarians. According to the economic concept of the value of a statistical life, the return on the investment for aortic valve replacement is enormous for patients of all ages, even very elderly patients.

  5. The role of three-dimensional visualization in robotics-assisted cardiac surgery

    NASA Astrophysics Data System (ADS)

    Currie, Maria; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W. A.; Patel, Rajni; Peters, Terry; Kiaii, Bob

    2012-02-01

    Objectives: The purpose of this study was to determine the effect of three-dimensional (3D) versus two-dimensional (2D) visualization on the amount of force applied to mitral valve tissue during robotics-assisted mitral valve annuloplasty, and the time to perform the procedure in an ex vivo animal model. In addition, we examined whether these effects are consistent between novices and experts in robotics-assisted cardiac surgery. Methods: A cardiac surgery test-bed was constructed to measure forces applied by the da Vinci surgical system (Intuitive Surgical, Sunnyvale, CA) during mitral valve annuloplasty. Both experts and novices completed roboticsassisted mitral valve annuloplasty with 2D and 3D visualization. Results: The mean time for both experts and novices to suture the mitral valve annulus and to tie sutures using 3D visualization was significantly less than that required to suture the mitral valve annulus and to tie sutures using 2D vision (p∠0.01). However, there was no significant difference in the maximum force applied by novices to the mitral valve during suturing (p = 0.3) and suture tying (p = 0.6) using either 2D or 3D visualization. Conclusion: This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery. Keywords: Robotics-assisted surgery, visualization, cardiac surgery

  6. Technical pitfalls and tips for the valve-in-valve procedure

    PubMed Central

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these

  7. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    PubMed

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  8. Tricuspid regurgitation in mitral valve disease incidence, prognostic implications, mechanism, and management.

    PubMed

    Shiran, Avinoam; Sagie, Alex

    2009-02-03

    Tricuspid regurgitation (TR) in patients with mitral valve (MV) disease is associated with poor outcome and predicts poor survival, heart failure, and reduced functional capacity. It is common if left untreated after MV replacement mainly in rheumatic patients, but it is also common in patients with ischemic mitral regurgitation. It is less common, however, in those with degenerative mitral regurgitation. It might appear many years after surgery and might not resolve after correcting the MV lesion. Late TR might be caused by prosthetic valve dysfunction, left heart disease, right ventricular (RV) dysfunction and dilation, persistent pulmonary hypertension, chronic atrial fibrillation, or by organic (mainly rheumatic) tricuspid valve disease. Most commonly, late TR is functional and isolated, secondary to tricuspid annular dilation. Outcome of isolated tricuspid valve surgery is poor, because RV dysfunction has already occurred at that point in many patients. MV surgery or balloon valvotomy should be performed before RV dysfunction, severe TR, or advanced heart failure has occurred. Tricuspid annuloplasty with a ring should be performed at the initial MV surgery, and the tricuspid annulus diameter (>or=3.5 cm) is the best criterion for performing the annuloplasty. In this article we will review the current data available for understanding the prognostic implications, mechanism, and management of TR in patients with MV disease.

  9. [Tricuspid valve insufficiency: what should be done?].

    PubMed

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  10. A Genomics-Based Model for Prediction of Severe Bioprosthetic Mitral Valve Calcification.

    PubMed

    Ponasenko, Anastasia V; Khutornaya, Maria V; Kutikhin, Anton G; Rutkovskaya, Natalia V; Tsepokina, Anna V; Kondyukova, Natalia V; Yuzhalin, Arseniy E; Barbarash, Leonid S

    2016-08-31

    Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification. A total of 124 consecutive Russian patients who underwent mitral valve replacement surgery were recruited. We investigated the associations of the inherited variation in innate immunity, lipid metabolism and calcium metabolism genes with severe bioprosthetic mitral valve calcification. Genotyping was conducted utilizing the TaqMan assay. Eight gene polymorphisms were significantly associated with severe bioprosthetic mitral valve calcification and were therefore included into stepwise logistic regression which identified male gender, the T/T genotype of the rs3775073 polymorphism within the TLR6 gene, the C/T genotype of the rs2229238 polymorphism within the IL6R gene, and the A/A genotype of the rs10455872 polymorphism within the LPA gene as independent predictors of severe bioprosthetic mitral valve calcification. The developed genomics-based model had fair predictive value with area under the receiver operating characteristic (ROC) curve of 0.73. In conclusion, our genomics-based approach is efficient for the prediction of severe bioprosthetic mitral valve calcification.

  11. A Genomics-Based Model for Prediction of Severe Bioprosthetic Mitral Valve Calcification

    PubMed Central

    Ponasenko, Anastasia V.; Khutornaya, Maria V.; Kutikhin, Anton G.; Rutkovskaya, Natalia V.; Tsepokina, Anna V.; Kondyukova, Natalia V.; Yuzhalin, Arseniy E.; Barbarash, Leonid S.

    2016-01-01

    Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification. A total of 124 consecutive Russian patients who underwent mitral valve replacement surgery were recruited. We investigated the associations of the inherited variation in innate immunity, lipid metabolism and calcium metabolism genes with severe bioprosthetic mitral valve calcification. Genotyping was conducted utilizing the TaqMan assay. Eight gene polymorphisms were significantly associated with severe bioprosthetic mitral valve calcification and were therefore included into stepwise logistic regression which identified male gender, the T/T genotype of the rs3775073 polymorphism within the TLR6 gene, the C/T genotype of the rs2229238 polymorphism within the IL6R gene, and the A/A genotype of the rs10455872 polymorphism within the LPA gene as independent predictors of severe bioprosthetic mitral valve calcification. The developed genomics-based model had fair predictive value with area under the receiver operating characteristic (ROC) curve of 0.73. In conclusion, our genomics-based approach is efficient for the prediction of severe bioprosthetic mitral valve calcification. PMID:27589735

  12. Surgical access via right thoracotomy facilitates tricuspid valve surgery in sheep

    PubMed Central

    Bothe, Wolfgang; Diab, Mahmoud; Ostermann, Romanus; Schwarzer, Michael; Woelfel, Luisa; Bischoff, Sabine; Schubert, Harald

    2017-01-01

    In quadrupeds, the three-dimensional orientation of the heart with respect to the thorax is fundamentally different from that in humans. In this study, we assessed the best surgical approach to the tricuspid valve in sheep. Firstly, different surgical access sites to the tricuspid valve were tested in sheep cadavers, the anatomy was analyzed, and the optimal surgical approach to the tricuspid valve was determined. Secondly - along with cardiopulmonary bypass and cardioplegic arrest -the chosen approach was tested in six adult sheep in vivo. Anatomical analyses revealed that a left thoracotomy provided optimal access to the aorta and left heart. However, visualization of the right heart was significantly impaired. In contrast, a right thoracotomy provided good access to the right heart, but the ascending aorta was difficult to approach. Therefore, in the in vivo studies, arterial cannulation was performed through a carotid (n = 4) or femoral (n = 2) artery. In conclusion, a right-sided thoracotomy allows good visualization of all components of the tricuspid valve complex in sheep, but not of the ascending aorta. Consequently, peripheral vessels are preferred for arterial cannulation. This work may stimulate the investigation of pathomechanisms and/or novel treatment options for tricuspid valve pathologies. PMID:27456775

  13. Prosthetic valve endocarditis 7 months after transcatheter aortic valve implantation diagnosed with 3D TEE.

    PubMed

    Sarı, Cenk; Durmaz, Tahir; Karaduman, Bilge Duran; Keleş, Telat; Bayram, Hüseyin; Baştuğ, Serdal; Özen, Mehmet Burak; Bayram, Nihal Akar; Bilen, Emine; Ayhan, Hüseyin; Kasapkara, Hacı Ahmet; Bozkurt, Engin

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) was introduced as an alternative treatment for patients with severe symptomatic aortic stenosis for whom surgery would be high-risk. Prosthetic aortic valve endocarditis is a serious complication of surgical AVR (SAVR) with high morbidity and mortality. According to recent cases, post-TAVI prosthetic valve endocarditis (PVE) seems to occur very rarely. We present the case of a 75-year-old woman who underwent TAVI (Edwards Saphien XT) with an uneventful postoperative stay. She was diagnosed with endocarditis using three dimensional (3D) echocardiography on the TAVI device 7 months later and she subsequently underwent surgical aortic valve replacement. Little experience of the interpretation of transoesophageal echocardiography (TEE) and the clinical course and effectiveness of treatment strategies in post-TAVI endocarditis exists. We report a case of PVE in a TAVI patient which was diagnosed with three-dimensional transoesophageal echocardiography (3DTEE). Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  14. [Commentary by the German Society for Thoracic and Cardiovascular Surgery on the positions statement by the German Cardiology Society on quality criteria for transcatheter aortic valve implantation (TAVI)].

    PubMed

    Cremer, Jochen; Heinemann, Markus K; Mohr, Friedrich Wilhelm; Diegeler, Anno; Beyersdorf, Friedhelm; Niehaus, Heidi; Ensminger, Stephan; Schlensak, Christian; Reichenspurner, Hermann; Rastan, Ardawan; Trummer, Georg; Walther, Thomas; Lange, Rüdiger; Falk, Volkmar; Beckmann, Andreas; Welz, Armin

    2014-12-01

    Surgical aortic valve replacement is still considered the first-line treatment for patients suffering from severe aortic valve stenosis. In recent years, transcatheter aortic valve implantation (TAVI) has emerged as an alternative for selected high-risk patients. According to the latest results of the German external quality assurance program, mandatory by law, the initially very high mortality and procedural morbidity have now decreased to approximately 6 and 12%, respectively. Especially in Germany, the number of patients treated by TAVI has increased exponentially. In 2013, a total of 10.602 TAVI procedures were performed. TAVI is claimed to be minimally invasive. This is true concerning the access, but it does not describe the genuine complexity of the procedure, defined by the close neighborhood of the aortic valve to delicate intracardiac structures. Hence, significant numbers of life-threatening complications may occur and have been reported. Owing to the complexity of TAVI, there is a unanimous concordance between cardiologists and cardiac surgeons in the Western world demanding a close heart team approach for patient selection, intervention, handling of complications, and pre- as well as postprocedural care, respectively. The prerequisite is that TAVI should not be performed in centers with no cardiac surgery on site. This is emphasized in all international joint guidelines and expert consensus statements. Today, a small number of patients undergo TAVI procedures in German hospitals without a department of cardiac surgery on site. To be noted, most of these hospitals perform less than 20 cases per year. Recently, the German Cardiac Society (DGK) published a position paper supporting this practice pattern. Contrary to this statement and concerned about the safety of patients treated this way, the German Society for Thoracic and Cardiovascular Surgery (DGTHG) still fully endorses the European (ESC/EACTS) and other actual international guidelines and

  15. Intraoperative application of geometric three-dimensional mitral valve assessment package: a feasibility study.

    PubMed

    Mahmood, Feroze; Karthik, Swaminathan; Subramaniam, Balachundhar; Panzica, Peter J; Mitchell, John; Lerner, Adam B; Jervis, Karinne; Maslow, Andrew D

    2008-04-01

    To study the feasibility of using 3-dimensional (3D) echocardiography in the operating room for mitral valve repair or replacement surgery. To perform geometric analysis of the mitral valve before and after repair. Prospective observational study. Academic, tertiary care hospital. Consecutive patients scheduled for mitral valve surgery. Intraoperative reconstruction of 3D images of the mitral valve. One hundred and two patients had 3D analysis of their mitral valve. Successful image reconstruction was performed in 93 patients-8 patients had arrhythmias or a dilated mitral valve annulus resulting in significant artifacts. Time from acquisition to reconstruction and analysis was less than 5 minutes. Surgeon identification of mitral valve anatomy was 100% accurate. The study confirms the feasibility of performing intraoperative 3D reconstruction of the mitral valve. This data can be used for confirmation and communication of 2-dimensional data to the surgeons by obtaining a surgical view of the mitral valve. The incorporation of color-flow Doppler into these 3D images helps in identification of the commissural or perivalvular location of regurgitant orifice. With improvements in the processing power of the current generation of echocardiography equipment, it is possible to quickly acquire, reconstruct, and manipulate images to help with timely diagnosis and surgical planning.

  16. Evaluation of nutritional screening tools among patients scheduled for heart valve surgery.

    PubMed

    Lomivorotov, Vladimir V; Efremov, Sergey M; Boboshko, Vladimir A; Nikolaev, Dmitry A; Vedernikov, Pavel E; Shilova, Anna N; Lomivorotov, Vladimir N; Karaskov, Alexander M

    2013-03-01

    The study aim was to detect the most sensitive nutritional screening tool and to assess its prognostic value with regards to an adverse clinical course in patients with heart valve disease undergoing cardiopulmonary bypass (CPB). This prospective cohort study included 441 adult patients who were screened using four nutritional screening tools: Nutritional Risk Screening 2002 (NRS-2002); Malnutrition Universal Screening Tool (MUST); Mini Nutritional Assessment (MNA); and Short Nutritional Assessment Questionnaire (SNAQ). Nutritional assessment was performed using a Subjective Global Assessment (SGA). In-hospital mortality, postoperative complications, and duration of hospital stay were each analyzed. With regards to the detection of malnutrition, the sensitivities of MUST, SNAQ, MNA and NRS-2002 were 100%, 92%, 84.6% and 43.6%, respectively. Malnutrition identified by MUST and MNA were associated with postoperative complications (OR 1.63, p = 0.033 and OR 1.6, p = 0.035) and prolonged hospitalization (OR 1.57, p = 0.048 and OR 1.7, p = 0.02). According to multivariate logistic regression analysis, along with well-known age and duration of CPB, malnutrition identified by MUST and MNA was associated with a risk of development of complications (OR 1.6, p = 0.049 and OR 1.6, p = 0.04, respectively). The sensitivities of SNAQ, MUST, NRS-2002 and MNA with regards to postoperative complications were 26.8%, 28.8%, 10%, and 31.6%, respectively. The MUST tool is preferable with regards to the detection of malnutrition. Both, MUST and MNA independently predicted postoperative complications. SNAQ and NRS-2002 proved insensitive with regards to the postoperative course among patients with heart valve disease who were scheduled for cardiothoracic surgery.

  17. Reoperations after tricuspid valve repair: re-repair versus replacement

    PubMed Central

    Hwang, Ho Young; Kim, Kyung-Hwan; Kim, Ki-Bong

    2016-01-01

    Background Data demonstrating results of reoperation after initial tricuspid valve repair are scarce. We evaluated outcomes of tricuspid reoperations after tricuspid valve repair and compared the results of tricuspid re-repair with those of tricuspid valve replacement (TVR). Methods From 1994 to 2012, 53 patients (56±15 years, male:female =14:39) underwent tricuspid reoperations due to recurrent tricuspid regurgitation (TR) after initial repair. Twenty-two patients underwent tricuspid re-repair (TAP group) and 31 patients underwent TVR (TVR group). Results Early mortality occurred in 6 patients (11%). Early mortality and incidence of postoperative complications were similar between the 2 groups. There were 14 cases of late mortality including 9 cardiac deaths. Five- and 10-year free from cardiac death rates were 82% and 67%, respectively, without any intergroup difference. Recurrent TR (> moderate) developed in 6 TAP group patients and structural valve deterioration occurred in 1 TVR group patient (P=0.002). Isolated tricuspid valve surgery (P=0.044) and presence of atrial fibrillation during the follow-up (P=0.051) were associated with recurrent TR after re-repair. However, the overall tricuspid valve-related event rates were similar between the 2 groups with 5- and 10-year rates of 61% and 41%, respectively. Conclusions Tricuspid valve reoperation after initial repair resulted in high rates of operative mortality and complications. Long-term event-free rate was similar regardless of the type of surgery. However, great care might be needed when performing re-repair in patients with atrial fibrillation and those who had isolated tricuspid valve disease due to high recurrence of TR after re-repair. PMID:26904221

  18. 3D printed mitral valve models: affordable simulation for robotic mitral valve repair.

    PubMed

    Premyodhin, Ned; Mandair, Divneet; Ferng, Alice S; Leach, Timothy S; Palsma, Ryan P; Albanna, Mohammad Z; Khalpey, Zain I

    2018-01-01

    3D printed mitral valve (MV) models that capture the suture response of real tissue may be utilized as surgical training tools. Leveraging clinical imaging modalities, 3D computerized modelling and 3D printing technology to produce affordable models complements currently available virtual simulators and paves the way for patient- and pathology-specific preoperative rehearsal. We used polyvinyl alcohol, a dissolvable thermoplastic, to 3D print moulds that were casted with liquid platinum-cure silicone yielding flexible, low-cost MV models capable of simulating valvular tissue. Silicone-moulded MV models were fabricated for 2 morphologies: the normal MV and the P2 flail. The moulded valves were plication and suture tested in a laparoscopic trainer box with a da Vinci Si robotic surgical system. One cardiothoracic surgery fellow and 1 attending surgeon qualitatively evaluated the ability of the valves to recapitulate tissue feel through surveys utilizing the 5-point Likert-type scale to grade impressions of the valves. Valves produced with the moulding and casting method maintained anatomical dimensions within 3% of directly 3D printed acrylonitrile butadiene styrene controls for both morphologies. Likert-type scale mean scores corresponded with a realistic material response to sutures (5.0/5), tensile strength that is similar to real MV tissue (5.0/5) and anatomical appearance resembling real MVs (5.0/5), indicating that evaluators 'agreed' that these aspects of the model were appropriate for training. Evaluators 'somewhat agreed' that the overall model durability was appropriate for training (4.0/5) due to the mounting design. Qualitative differences in repair quality were notable between fellow and attending surgeon. 3D computer-aided design, 3D printing and fabrication techniques can be applied to fabricate affordable, high-quality educational models for technical training that are capable of differentiating proficiency levels among users. © The Author 2017

  19. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    PubMed

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p < 0.01). Patient-specific, 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  20. [Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].

    PubMed

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.

  1. 49 CFR 236.383 - Valve locks, valves, and valve magnets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve locks, valves, and valve magnets. 236.383... Inspection and Tests § 236.383 Valve locks, valves, and valve magnets. Valve locks on valves of the non-cut-off type shall be tested at least once every three months, and valves and valve magnets shall be...

  2. Peri-operative oral caffeine does not prevent postoperative atrial fibrillation after heart valve surgery with cardiopulmonary bypass: A randomised controlled clinical trial.

    PubMed

    Lagier, David; Nee, Laetitia; Guieu, Régis; Kerbaul, François; Fenouillet, Emmanuel; Roux, Nicolas; Giorgi, Roch; Theron, Alexis; Grisoli, Dominique; Gariboldi, Vlad; Collart, Frederic; Bruder, Nicolas; Velly, Lionel; Guidon, Catherine

    2018-04-26

    Raised plasma levels of endogenous adenosine after cardiac surgery using cardiopulmonary bypass (CPB) have been related to the incidence of postoperative atrial fibrillation (POAF). We wished to assess if caffeine, an adenosine receptor antagonist could have a beneficial effect on the incidence of POAF. A randomised controlled study. Single University Hospital. One hundred and ten patients scheduled for heart valve surgery with CPB. We randomly assigned patients to receive peri-operative oral caffeine (400 mg every 8 h for 2 days) or placebo. Adenosine plasma concentrations and caffeine pharmacokinetic profile were evaluated in a subgroup of 50 patients. The primary endpoint was the rate of atrial fibrillation during postoperative hospital stay. The current study was stopped for futility by the data monitoring board after an interim analysis. The incidence of atrial fibrillation was similar in the caffeine and in the placebo group during hospital stay (33 vs. 29%, P = 0.67) and the first 3 postoperative days (18 vs. 15%; P = 0.60). Basal and postoperative adenosine plasma levels were significantly associated with the primary outcome. Adenosine plasma levels were similar in the two treatment groups. Caffeine administration was associated with a higher incidence of postoperative nausea and vomiting (27 vs. 7%, P = 0.005). Oral caffeine does not prevent POAF after heart valve surgery with CPB but increased the incidence of postoperative nausea and vomiting. ClinicalTrials.gov, no.: NCT01999829.

  3. Surgical results of reoperative tricuspid surgery: analysis from the Japan Cardiovascular Surgery Database†.

    PubMed

    Umehara, Nobuhiro; Miyata, Hiroaki; Motomura, Noboru; Saito, Satoshi; Yamazaki, Kenji

    2014-07-01

    Tricuspid valve insufficiency (TI) following cardiovascular surgery causes right-side heart failure and hepatic failure, which affect patient prognosis. Moreover, the benefits of reoperation for severe tricuspid insufficiency remain unclear. We investigated the surgical outcomes of reoperation in TI. From the Japan Cardiovascular Surgery Database (JACVSD), we extracted cases who underwent surgery for TI following cardiac surgery between January 2006 and December 2011. We analysed the surgical outcomes, specifically comparing tricuspid valve replacement (TVR) and tricuspid valve plasty (TVP). Of the 167 722 surgical JACVSD registered cases, reoperative TI surgery occurred in 1771 cases, with 193 TVR cases and 1578 TVP cases. The age and sex distribution was 684 males and 1087 females, with an average age of 66.5 ± 10.8 years. The overall hospital mortality was 6.8% and was significantly higher in the TVR group than in the TVP group (14.5 vs 5.8%, respectively; P < 0.001). Incidences of dialysis, prolonged ventilation and heart block were also significantly higher in the TVR group than in the TVP group. Logistic regression analysis revealed that the risk factors of hospital mortality were older age, preoperative renal dysfunction, preoperative New York Heart Association Class 4, left ventricular dysfunction and TVR. Surgical outcomes following reoperative tricuspid surgery were unsatisfactory. Although TVR is a last resort for non-repairable tricuspid lesions, it carries a significant risk of surgical mortality. Improving the patient's preoperative status and opting for TVP over TVR is necessary to improve the results of reoperative tricuspid surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Normothermic cardiopulmonary bypass increases cerebral tissue oxygenation during combined valve surgery: a single-centre, randomized trial.

    PubMed

    Lenkin, Andrey I; Zaharov, Viktor I; Lenkin, Pavel I; Smetkin, Alexey A; Bjertnaes, Lars J; Kirov, Mikhail Y

    2013-05-01

    In cardiac surgery, the choice of temperature regimen during cardiopulmonary bypass (CPB) remains a subject of debate. Hypothermia reduces tissue metabolic demands, but may impair the autoregulation of cerebral blood flow and contribute to neurological morbidity. The aim of this study was to evaluate the effect of two different temperature regimens during CPB on the systemic oxygen transport and the cerebral oxygenation during surgical correction of acquired heart diseases. In a prospective study, we randomized 40 adult patients with combined valvular disorders requiring surgical correction of two or more valves into two groups: (i) a normothermic (NMTH) group (n = 20), in which the body core temperature was maintained at 36.6°C during CPB and (ii) a hypothermic (HPTH) group (n = 20), in which the body was cooled to a core temperature of 32°C maintained throughout the period of CPB. The systemic oxygen transport and the cerebral oxygen saturation (SctO2) were assessed by means of a PiCCO2 haemodynamic monitor and a cerebral oximeter, respectively. All the patients received standard perioperative monitoring. We assessed haemodynamic and oxygen transport parameters, the duration of mechanical ventilation and the length of the ICU and the hospital stays. During CPB, central venous oxygen saturation was significantly higher in the HPTH group but SctO2 was increased in the NMTH group (P < 0.05). Cardiac index, systemic oxygen delivery and consumption increased postoperatively in both groups. However, oxygen delivery and consumption were significantly higher in the NMTH group (P < 0.05). The duration of respiratory support and the length of ICU and hospital stays did not differ between the groups. During combined valve surgery, normothermic CPB provides lower central venous oxygen saturation, but increases cerebral tissue oxygenation when compared with the hypothermic regimen.

  5. Congenital absence of pulmonary valve leaflets.

    PubMed Central

    Buendia, A; Attie, F; Ovseyevitz, J; Zghaib, A; Zamora, C; Zavaleta, D; Vargas-Barron, J; Richheimer, R

    1983-01-01

    Congenital absence of pulmonary valve leaflets is an uncommon condition usually associated with ventricular septal defect and an obstructive pulmonary valve ring. Twenty-one patients with these malformations are described. Twenty had an associated ventricular septal defect with ventriculoarterial concordance, and one also had transposition of the great arteries, ventricular septal defect, and obstructive pulmonary valve ring. The clinical features, cardiac catheterisation findings, and angiocardiographic results are presented. Twelve patients underwent cardiac surgery. Three patients died, one in the early, and the other two in the late postoperative period. The results, according to the surgical technique employed and postoperative cardiac catheterisation findings, showed that patients in whom the bioprostheses were implanted in the pulmonary position had a better late follow-up. Images PMID:6860509

  6. Outcomes of Heimlich valve drainage in dogs.

    PubMed

    Salci, H; Bayram, A S; Gorgul, O S

    2009-04-01

    Retrospective study of the outcomes of Heimlich valve drainage in dogs. Medical records of the past 3 years were retrospectively reviewed. Heimlich valve drainage was used in 34 dogs (median body weight 30 +/- 5 kg): lobectomy (n = 15), pneumonectomy (n = 9), intrathoracic oesophageal surgery (n = 2), diaphragmatic hernia repair (n = 1), traumatic open pneumothorax (n = 2), bilobectomy (n = 2), ligation of the thoracic duct (n = 1), and chylothorax and pneumothorax (n = 1 each). Evacuation of air and/or fluid from the pleural cavity was performed with the Heimlich valve following thoracostomy tube insertion. During drainage, the dogs were closely monitored for possible respiratory failure. Termination of Heimlich valve drainage was controlled with underwater seal drainage and assessed with thoracic radiography. Negative intrathoracic pressure was provided in 29 dogs without any complications. Post pneumonectomy respiratory syncope and post lobectomy massive hemothorax, which did not originate from the Heimlich valve, were the only postoperative complications. Dysfunction of the valve diaphragm, open pneumothorax and intrathoracic localisation of an acute gastric dilatation-volvulus syndrome caused by a left-sided diaphragmatic hernia following pneumonectomy were the Heimlich valve drainage complications. The Heimlich valve can be used as a continuous drainage device in dogs, but the complications reported here should be considered by veterinary practitioners.

  7. Effect of prior aortic valve intervention on results of the Ross operation.

    PubMed

    Sakaguchi, Hidehito; Elkins, Ronald C; Lane, Mary M; McCue, Carolyn

    2003-07-01

    Patient-related factors, aortic insufficiency, bicuspid aortic valve, aortic annulus dilatation, ascending aortic dilatation or aneurysm, and aortic valve endocarditis have been suggested as affecting the results of the Ross operation. The study aim was to assess the impact of prior aortic valve intervention on early and late results of a Ross operation. A total of 399 patients who underwent surgery between August 1986 and September 2000 were reviewed retrospectively. The patients were grouped as: no prior aortic valve intervention (NOAVI, n = 219); prior aortic valvuloplasty (AVP, n = 106); prior balloon aortic valvuloplasty (AVB, n = 40); and prior aortic valve replacement (AVR, n = 34). Details of operative and late mortality, autograft valve function, and homograft valve function were analyzed. Operative mortality was higher for AVB (10%; three deaths in neonates) than the other groups (from 2.3% to 5.9%) (p = 0.084). Freedom from autograft valve degeneration, defined as severe autograft valve insufficiency, non-endocarditis autograft valve reoperation or valve-related death, ranged from 93 +/- 3% for AVP to 76 +/- 8% for NOAVI at 10 years (p = 0.43). Freedom from homograft reoperation in the pulmonary position was 100% for AVB at six years, and 99 +/- 1% for AVP, 82 +/- 8% for NOAVI, and 70 +/- 13% for AVR at 10 years (p = 0.0026). There appears to be no significant difference between patients with and without prior aortic valve surgery, with respect to operative mortality or late autograft function. However, patients with prior AVR appear to have a significantly higher homograft reoperation rate after a Ross operation, the reasons for which are uncertain.

  8. Should Moderate-to-Severe Tricuspid Regurgitation be Repaired During Reoperative Left-Sided Valve Procedures?

    PubMed

    Gosev, Igor; Yammine, Maroun; McGurk, Siobhan; Ejiofor, Julius I; Norman, Anthony; Ivkovic, Vladimir; Cohn, Lawrence H

    The risks vs benefits of tricuspid valve (TV) surgery in reoperative patients requiring left-sided valve surgery and moderate-to-severe tricuspid regurgitation is unclear. We compared patients with and without concomitant TV surgery. A total of 200 patients with moderate-to-severe TV regurgitation had reoperative left-sided valve procedures from January 2002 to April 2014; 75 with TV intervention (TVI) and 125 with no tricuspid intervention (TVN). Propensity-matched cohorts of 60 TVI and 60 TVN patients were compared. Outcomes included New York Heart Association class, TV regurgitation and survival. TVI patients were younger (66 ± 15 vs 72 ± 13 years, P < 0.001), had more cardiogenic shock (6 of 75, vs 0 of 125, P < 0.001) and mitral valve surgery (60 of 75 vs 69 of 125, P < 0.001). Propensity matching yielded 60 pairs of TVI cases and TVN controls. Matched groups were comparable in age (TVI = 67 ± 13 vs TVN 68 ± 14 years, P = 0.67), cardiogenic shock (2 vs 0, P = 0.50), and mitral valve surgery (15 each, P = 1.0). Operative mortality was 2 of 60 in TVI vs 10 of 60 TVN (P = 0.27). Median follow-up was 4.4 years. Follow-up rates of New York Heart Association class III-IV were similar (12 of 60 for TVI vs 16 of 60 TVN, P = 0.52). Kaplan-Meier analysis indicated improved event-free survival for TVI patients (6 years, 95% CI: 4.8-7.2 years vs 8 years, 95% CI: 6.7-9.3 years for TVN, P = 0.030). There was a trend towards increased TR at follow-up in patients with valve repair alone vs annuloplasty (P = 0.15). TV surgery was performed more often in higher-risk patients. Matched case-control analyses showed TVI was associated with improved midterm outcomes. Our data suggest that annuloplasty was preferable to TV repair alone. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Surgical revision after percutaneous mitral valve repair by edge-to-edge device: when the strategy fails in the highest risk surgical population.

    PubMed

    Alozie, Anthony; Westphal, Bernd; Kische, Stephan; Kaminski, Alexander; Paranskaya, Liliya; Bozdag-Turan, Ilkay; Ortak, Jasmin; Schubert, Jochen; Steinhoff, Gustav; Ince, Hüseyin

    2014-07-01

    Percutaneous edge-to-edge devices for non-surgical repair of mitral valve regurgitation are under clinical evaluation in high-risk patients deemed not suitable for conventional surgery. To address guidelines for initial therapy decision, we here report on 13 cases of surgery after failed percutaneous edge-to-edge mitral valve repair or attempted repair, and discuss methodology and prognostic factors for operative outcome in this high-risk situation. Thirteen patients referred to our cardiothoracic unit after failed percutaneous mitral valve repair or attempted repair using the edge-to-edge technique, were treated surgically for mitral valve failure between June 2010 and December 2012. Pathology of mitral valve before and after interventional mitral valve repair (especially prevalent mode of failure) was evaluated and classified for each individual patient by echocardiography and intraoperative direct visualization. Number of implanted edge-to-edge devices were identified. Preoperative risk scores were matched with intraoperative observations and histopathological findings of valve tissue. Postoperative morbidity and mortality were analysed with respect to mitral valve and patient-related data. Three of 10 patients were referred with severe mitral valve regurgitation/stenosis after initially successful percutaneous edge-to-edge therapy or attempted therapy. In 3 patients, ≥ 2 edge-to-edge devices were implanted leading to very tight edge-to-edge leaflet connection and fibrosis. All patients underwent successful surgical mitral valve replacement and concomitant complete cardiac surgery (CABG, aortic or tricuspid valve surgery, ASD closure and pulmonary vein isolation for atrial fibrillation). The likelihood of repair was reduced with respect to multiple edge-to-edge technology. One device could not be harvested surgically because of embolization. One patient died on the second postoperative day due to sepsis with multiple organ failure. The remaining 12 patients

  10. Failing stentless Bioprostheses in patients with carcinoid heart valve disease.

    PubMed

    Schaefer, Andreas; Sill, Bjoern; Schoenebeck, Jeannette; Schneeberger, Yvonne; Reichenspurner, Hermann; Gulbins, Helmut

    2015-03-27

    Carcinoid tumor with consecutive endocardial fibroelastosis of the right heart, known as carcinoid heart valve disease (CHVD) or Hedinger's syndrome, is accompanied by combined right-sided valvular dysfunction with regurgitation and stenosis of the affected valves. Cardiac surgery with replacement of the tricuspid and/or pulmonary valve is an established therapeutic option for patients with Hedinger's syndrome. Little is known about the long term outcome and the choice of prosthesis for the pulmonal position is still a matter of debate. The authors report three cases of pulmonary valve replacement with stentless bioprostheses (Medtronic Freestyle, Medtronic PLC, Minneapolis, MN, USA) due to severe pulmonary valve degeneration in consequence of Hedinger's syndrome. All patients presented with re-stenosis of the pulmonal valve conduit at the height of the anastomoses in a premature fashion. Due to the increased risk for repeat surgical valve replacement, two patients were treated by transcatheter heart valves. We do not recommend the replacement of the pulmonary valve with stentless bioprostheses in patients with CHVD. These valves presented with an extreme premature degeneration and consecutive re-stenosis and heart failure.

  11. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    PubMed

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  12. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis

    PubMed Central

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Objective Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Methods Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. Results A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). Conclusion The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in

  13. Development of a Risk Prediction Model and Clinical Risk Score for Isolated Tricuspid Valve Surgery.

    PubMed

    LaPar, Damien J; Likosky, Donald S; Zhang, Min; Theurer, Patty; Fonner, C Edwin; Kern, John A; Bolling, Stephen F; Drake, Daniel H; Speir, Alan M; Rich, Jeffrey B; Kron, Irving L; Prager, Richard L; Ailawadi, Gorav

    2018-02-01

    While tricuspid valve (TV) operations remain associated with high mortality (∼8-10%), no robust prediction models exist to support clinical decision-making. We developed a preoperative clinical risk model with an easily calculable clinical risk score (CRS) to predict mortality and major morbidity after isolated TV surgery. Multi-state Society of Thoracic Surgeons database records were evaluated for 2,050 isolated TV repair and replacement operations for any etiology performed at 50 hospitals (2002-2014). Parsimonious preoperative risk prediction models were developed using multi-level mixed effects regression to estimate mortality and composite major morbidity risk. Model results were utilized to establish a novel CRS for patients undergoing TV operations. Models were evaluated for discrimination and calibration. Operative mortality and composite major morbidity rates were 9% and 42%, respectively. Final regression models performed well (both P<0.001, AUC = 0.74 and 0.76) and included preoperative factors: age, gender, stroke, hemodialysis, ejection fraction, lung disease, NYHA class, reoperation and urgent or emergency status (all P<0.05). A simple CRS from 0-10+ was highly associated (P<0.001) with incremental increases in predicted mortality and major morbidity. Predicted mortality risk ranged from 2%-34% across CRS categories, while predicted major morbidity risk ranged from 13%-71%. Mortality and major morbidity after isolated TV surgery can be predicted using preoperative patient data from the STS Adult Cardiac Database. A simple clinical risk score predicts mortality and major morbidity after isolated TV surgery. This score may facilitate perioperative counseling and identification of suitable patients for TV surgery. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. The impact of concomitant pulmonary hypertension on early and late outcomes following surgery for mitral stenosis.

    PubMed

    Yang, Bo; DeBenedictus, Christina; Watt, Tessa; Farley, Sean; Salita, Alona; Hornsby, Whitney; Wu, Xiaoting; Herbert, Morley; Likosky, Donald; Bolling, Steven F

    2016-08-01

    To provide initial evidence on the management of mitral stenosis and pulmonary hypertension (PH) based on short-term and long-term outcomes following mitral valve surgery. Consecutive patients with mitral stenosis (n = 317) who had undergone mitral valve surgery between 1992 and 2014 with recorded pulmonary artery pressure (PAP) data were reviewed. PH severity, based on systolic PAP, was categorized as mild (35 to 44 mm Hg), moderate (45 to 59 mm Hg), or severe (>60 mm Hg). Primary outcomes were 30-day mortality and long-term survival. There were no significant between-group differences in age or preoperative comorbidities. Mitral valve surgery included mitral valve replacement (78%) and repair (22%). The severe PH group had more mitral valve replacement (81%; P = .04), severe tricuspid valve regurgitation (31%; P = .003), right heart failure (17%; P = .02), and concomitant tricuspid valve procedures (46%; P < .001). For severe PH, 30-day mortality was 9%, with no significant group differences. Ten- and 12-year survival were significantly worse in the moderate-severe PH group (58% and 51%, respectively) compared with the normal PAP-mild PH group (83% and 79%, respectively) with a hazard ratio of 2.98 (95% confidence interval, 1.55-5.75; P = .001). Ten-year survival after mitral valve surgery for mitral stenosis was inversely associated with preoperative PAP. Mitral valve surgery can be performed with acceptable 30-day mortality for patients with mitral stenosis and moderate to severe PH, but long-term survival is impaired by moderate to severe PH. Patients with mitral stenosis and mild PH (systolic PAP 35-44 mm Hg) should be considered for mitral valve surgery. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Anterior Urethral Valve: Uncommon Association with Renal Duplicity.

    PubMed

    Salem, Amina Ben; Mazhoud, Ines; Laamiri, Rachida; Salem, Randa; Laajili, Hayet; Sahnoun, Lassaad; Hafsa, Chiraz

    2017-01-01

    Anterior urethral valves (AUVs) is an unusual cause of congenital obstruction of the male urethra, being 15-30 times less common than posterior urethral valves. We present a case of AUV diagnosed at 24th gestational week. Ultrasonography and fetal MRI revealed hydronephrotic kidneys with ureteral duplicity, a distended bladder and perineal cystic mass which confirmed dilated anterior urethra in a male fetus. Diagnosis was confirmed postnatally by voiding cystourethrogram and surgery.

  16. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    PubMed

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P < 0.001). Pressures outside adjacent sutures (extrasuture) were less than 80 mm Hg in 10 of 60 HT, zero of 60 KP, and zero of 120 TF sites for 15 × 4-mm valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P < 0.001 all manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.

  17. Constitutive modeling of jugular vein-derived venous valve leaflet tissues.

    PubMed

    Kaul, Nayyan; Huang, Hsiao-Ying Shadow

    2017-11-01

    Venous valve tissues, though used in vein reconstruction surgeries and bioprosthetic valves with moderate success, have not been extensively studied with respect to their structure. Their inherent anisotropic, non-linear behavior combined with severe diseases which affect veins, such as chronic venous insufficiency, warrant understanding the structure and material behavior of these tissues. Hence, before any bioprosthetic grafts may be used in place of tissues, it is of the utmost importance to understand the mechanical and structural properties of these tissues as this may lead to higher success rates for valve replacement surgeries. The longevity of the bioprosthetics may also increase if the manufactured grafts behave the same as native valves. Building on the scant information about the uniaxial and biaxial mechanical properties of jugular venous valves and wall tissues from previous studies, the current focus of our investigation lies in understanding the material behavior by establishing a phenomenological strain energy-based constitutive relation for the tissues. We used bovine veins to study the behavior of valve leaflet tissue and adjoining wall tissue (from the proximal and distal ends of the veins) under different biaxial testing protocols. We looked at the behavior of numerical partial derivatives of the strain energy to select a suitable functional form for the strain energy for wall and valve tissues. Using this strain energy descriptor, we determined the Cauchy stress and compared it with experimental results under additional sets of displacement-controlled biaxial testing protocols to find material specific model parameters by the Powell's method algorithm. Results show that whereas wall tissue strain energy can be explained using a polynomial non-linear function, the valve tissue, due to higher non-linearities, requires an exponential function. This study may provide useful information for the primary stages of bioprosthetic designs and replacement

  18. Work Status and Return to the Workforce after Coronary Artery Bypass Grafting and/or Heart Valve Surgery: A One-Year-Follow Up Study.

    PubMed

    Fonager, Kirsten; Lundbye-Christensen, Søren; Andreasen, Jan Jesper; Futtrup, Mikkel; Christensen, Anette Luther; Ahmad, Khalil; Nørgaard, Martin Agge

    2014-01-01

    Background. Several characteristics appear to be important for estimating the likelihood of reentering the workforce after surgery. The aim of the present study was to describe work status in a two-year time period around the time of cardiac surgery and estimate the probability of returning to the workforce. Methods. We included 681 patients undergoing coronary artery bypass grafting and/or heart valve procedures from 2003 to 2007 in the North Denmark Region. We linked hospital data to data in the DREAM database which holds information of everyone receiving social benefits. Results. At the time of surgery 17.3% were allocated disability pension and 2.3% were allocated a permanent part-time benefit. Being unemployed one year before surgery reduced the likelihood of return to the workforce (RR = 0.74 (0.60-0.92)) whereas unemployment at the time of surgery had no impact on return to the workforce (RR = 0.96 (0.78-1.18)). Sickness absence before surgery reduced the likelihood of return to the workforce. Conclusion. This study found the work status before surgery to be associated with the likelihood of return to the workforce within one year after surgery. Before surgery one-fifth of the population either was allocated disability pension or received a permanent part-time benefit.

  19. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    PubMed

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. A new beating-heart mitral and aortic valve assessment model with implications for valve intervention training.

    PubMed

    Bouma, Wobbe; Jainandunsing, Jayant S; Khamooshian, Arash; van der Harst, Pim; Mariani, Massimo A; Natour, Ehsan

    2017-02-01

    A thorough understanding of mitral and aortic valve motion dynamics is essential in mastering the skills necessary for performing successful valve intervention (open or transcatheter repair or replacement). We describe a reproducible and versatile beating-heart mitral and aortic valve assessment and valve intervention training model in human cadavers. The model is constructed by bilateral ligation of the pulmonary veins, ligation of the supra-aortic arteries, creating a shunt between the descending thoracic aorta and the left atrial appendage with a vascular prosthesis, anastomizing a vascular prosthesis to the apex and positioning an intra-aortic balloon pump (IABP) in the vascular prosthesis, cross-clamping the descending thoracic aorta, and finally placing a fluid line in the shunt prosthesis. The left ventricle is filled with saline to the desired pressure through the fluid line, and the IABP is switched on and set to a desired frequency (usually 60-80 bpm). Prerepair valve dynamic motion can be studied under direct endoscopic visualization. After assessment, the IABP is switched off, and valve intervention training can be performed using standard techniques. This high-fidelity simulation model has known limitations, but provides a realistic environment with an actual beating (human) heart, which is of incremental value. The model provides a unique opportunity to fill a beating heart with saline and to study prerepair mitral and aortic valve dynamic motion under direct endoscopic visualization. The entire set-up provides a versatile beating-heart mitral and aortic valve assessment model, which may have important implications for future valve intervention training. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Textile for heart valve prostheses: fabric long-term durability testing.

    PubMed

    Heim, Frederic; Durand, Bernard; Chakfe, Nabil

    2010-01-01

    The rapid developments and success in percutaneous vascular surgery over the last two decades with the now common stent grafts implantation, make the noninvasive surgery technique today attractive even for heart valve replacement. Less traumatic for the patient and also less time consuming, percutaneous heart valve replacement is however at its beginning and restricted to end of life patients. The noninvasive procedure expects from the heart valve prosthesis material to be resistant and adapted to folding requirements of the implantation process (catheter). Polyester fabric could be a suited material for heart valve implanted percutaneously. Highly flexible and resistant, polyester fabric proved to be well adapted to the dynamic behavior of a valve and polyester (Dacron) is also widely used for vascular grafts implantation and shows good biocompatibility and durability. However, today there's no data available on long-term durability of fabric used as heart valve material. The purpose of this work is to study the long term behavior of a microdenier polyester fabric construction under combined in vitro flexure and tension fatigue stress. In the novel in vitro testing technique presented, a fabric specimen was subjected to combined flexural and tensile fatigue generated by fluid flow under physiological pressure conditions. The results obtained show how flexural properties change with fatigue time, which reflects directly on the suitability of a fabric in such devices. It was also observed that these fabric structural changes directly influence the in vitro behavior of the textile heart valve prosthesis. (c) 2009 Wiley Periodicals, Inc.

  2. Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management.

    PubMed

    Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi

    2006-01-01

    Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.

  3. Emergency aortic valve replacement and Caesarian section in a primigravida with severe aortic stenosis: a case report.

    PubMed

    Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P

    2011-01-01

    Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).

  4. Prosthetic valve endocarditis: who needs surgery? A multicentre study of 104 cases

    PubMed Central

    Habib, G; Tribouilloy, C; Thuny, F; Giorgi, R; Brahim, A; Amazouz, M; Remadi, J-P; Nadji, G; Casalta, J-P; Coviaux, F; Avierinos, J-F; Lescure, X; Riberi, A; Weiller, P-J; Metras, D; Raoult, D

    2005-01-01

    Objectives: To identify the prognostic markers of a bad outcome in a large population of 104 patients with prosthetic valve endocarditis (PVE), and to study the influence of medical versus surgical strategy on outcome in PVE and thus to identify patients for whom surgery may be beneficial. Design: Multicentre study. Methods and results: Among 104 patients, 22 (21%) died in hospital. Factors associated with in-hospital death were severe co-morbidity (6% of survivors v 41% of those who died, p  =  0.05), renal failure (28% v 45%, p  =  0.05), moderate to severe regurgitation (22% v 54%, p  =  0.006), staphylococcal infection (16% v 54%, p  =  0.001), severe heart failure (22% v 64%, p  =  0.001), and occurrence of any complication (60% v 90%, p  =  0.05). By multivariate analysis, severe heart failure (odds ratio 5.5) and Staphylococcus aureus infection (odds ratio 6.1) were the only independent predictors of in-hospital death. Among 82 in-hospital survivors, 21 (26%) died during a 32 month follow up. A Cox proportional hazards model identified early PVE, co-morbidity, severe heart failure, staphylococcus infection, and new prosthetic dehiscence as independent predictors of long term mortality. Mortality was not significantly different between surgical and non-surgical patients (17% v 25%, respectively, not significant). However, both in-hospital and long term mortality were reduced by a surgical approach in high risk subgroups of patients with staphylococcal PVE and complicated PVE. Conclusions: Firstly, PVE not only carries a high in-hospital mortality risk but also is associated with high long term mortality and needs close follow up after the initial episode. Secondly, congestive heart failure, early PVE, staphylococcal infection, and complicated PVE are associated with a bad outcome. Thirdly, subgroups of patients could be identified for whom surgery is associated with a better outcome: patients with staphylococcal and complicated PVE

  5. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    PubMed

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  6. Performance of stented biological valves for right ventricular outflow tract reconstruction.

    PubMed

    Buchholz, Christian; Mayr, Andreas; Purbojo, Ariawan; Glöckler, Martin; Toka, Okan; Cesnjevar, Robert A; Rüffer, André

    2016-12-01

    This retrospective single-centre review presents mid- and long-term results of stented biological valves (SBVs) in the pulmonary position. Fifty-two SBVs (17 Carpentier-Edwards Supraannular; 13 Carpentier-Edwards Perimount; 12 St. Jude Medical Trifecta; 4 Sorin Mitroflow; 4 Sorin Soprano; 2 Sorin More) were implanted between 2000 and 2015. The median valve size, patient age and weight were 23 mm (range 19-27), 22.8 years (range 5-77) and 62.0 kg (range 14-110), respectively. The main cardiac diagnosis was tetralogy of Fallot in 26 patients (50%). Forty-four patients (85%) had previous cardiac surgery; 12 patients (23%) had previous conduit or biological valve replacement. Valve degeneration was defined as a valvular peak pressure gradient >50 mmHg or pulmonary valve regurgitation more than moderate. The mean follow-up was 7.9 ± 5.5 years. Two patients died after 5.8 and 6.1 years of causes not related to SBVs. Eleven SBVs (21%) had to be replaced surgically (n = 6) or interventionally (n = 5) after 9.0 ± 4.1 years due to valve degeneration (n = 8), endocarditis (n = 2) or right ventricular dysfunction (n = 1). The rates of freedom from valve replacement were 100%, 92% [95% confidence interval (CI) 79-97], 81% (CI 64-91) and 60% (CI 40-78) after 1, 5, 10 and 15 years, respectively. Successful interventional valve-in-valve implantation resulted in 100% freedom from surgical valve replacement in all patients older than 19.1 years. Multivariate analysis identified patient age <19.1 years (P = 0.007) as a risk factor for earlier valve degeneration. SBVs in the pulmonary position showed encouraging long-term results in mature patients. The design of SBVs enables interventional valve implantation, postponing the need for reoperation. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Underlying Rheumatic Disease: An Important Determinant of Outcome in Tricuspid Valve Repair.

    PubMed

    Munasur, Mandhir; Naidoo, Datshana

    2016-03-01

    Tricuspid regurgitation (TR) accompanying severe left-sided valve disease occurs on a functional basis, secondary to pulmonary hypertension and tricuspid annular dilatation. In the context of endemic left-sided rheumatic heart disease, non-recognition of organic disease of the tricuspid valve may adversely influence surgical decision-making, resulting in suboptimal outcomes. A retrospective analysis of the perioperative and follow up data of 30 patients who underwent tricuspid valve surgery with concomitant left-sided valve replacement was undertaken. Preoperative evaluation by two-dimensional transthoracic echocardiography was routinely employed. Outcomes were analyzed by evaluation of the perioperative and two-year follow up clinical and echocardiographic data. All subjects had severe TR. Mixed tricuspid valve disease occurred in 11 subjects (36.7%). Tricuspid valve repair was performed in 28 patients. A significant improvement (p <0.05) in the following parameters occurred at six weeks postoperatively: NYHA functional class, tricuspid annular diameter, systolic pulmonary artery pressure, severity of TR and tricuspid transvalvular gradient. Severe residual postoperative TR occurred in 26.7% of patients, but there were no identifiable predictors for this phenomenon. Severe residual postoperative TR was not associated with major adverse cardiovascular events. Preoperative (p = 0.013) and postoperative (p<0.002) pulmonary hypertension were associated with the development of major adverse cardiovascular events. The technique of tricuspid valve repair was not associated with the occurrence of major adverse cardiovascular events, nor with the development of severe residual postoperative TR. A satisfactory outcome was observed in only 40% of the study population. The coexistence of mixed tricuspid valve disease in rheumatic heart disease patients undergoing left-sided valve surgery is an important determinant of outcome in tricuspid valve repair. The persistence of

  8. Tricuspid valve excision using off-pump inflow occlusion technique: role of intra-operative trans-esophageal echocardiography.

    PubMed

    Gadhinglajkar, Shrinivas; Sreedhar, Rupa; Karunakaran, Jayakumar; Misra, Manoranjan; Somasundaram, Ganesh; Mathew, Thomas

    2010-01-01

    A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure.

  9. Percutaneous repair or surgery for mitral regurgitation.

    PubMed

    Feldman, Ted; Foster, Elyse; Glower, Donald D; Glower, Donald G; Kar, Saibal; Rinaldi, Michael J; Fail, Peter S; Smalling, Richard W; Siegel, Robert; Rose, Geoffrey A; Engeron, Eric; Loghin, Catalin; Trento, Alfredo; Skipper, Eric R; Fudge, Tommy; Letsou, George V; Massaro, Joseph M; Mauri, Laura

    2011-04-14

    Mitral-valve repair can be accomplished with an investigational procedure that involves the percutaneous implantation of a clip that grasps and approximates the edges of the mitral leaflets at the origin of the regurgitant jet. We randomly assigned 279 patients with moderately severe or severe (grade 3+ or 4+) mitral regurgitation in a 2:1 ratio to undergo either percutaneous repair or conventional surgery for repair or replacement of the mitral valve. The primary composite end point for efficacy was freedom from death, from surgery for mitral-valve dysfunction, and from grade 3+ or 4+ mitral regurgitation at 12 months. The primary safety end point was a composite of major adverse events within 30 days. At 12 months, the rates of the primary end point for efficacy were 55% in the percutaneous-repair group and 73% in the surgery group (P=0.007). The respective rates of the components of the primary end point were as follows: death, 6% in each group; surgery for mitral-valve dysfunction, 20% versus 2%; and grade 3+ or 4+ mitral regurgitation, 21% versus 20%. Major adverse events occurred in 15% of patients in the percutaneous-repair group and 48% of patients in the surgery group at 30 days (P<0.001). At 12 months, both groups had improved left ventricular size, New York Heart Association functional class, and quality-of-life measures, as compared with baseline. Although percutaneous repair was less effective at reducing mitral regurgitation than conventional surgery, the procedure was associated with superior safety and similar improvements in clinical outcomes. (Funded by Abbott Vascular; EVEREST II ClinicalTrials.gov number, NCT00209274.).

  10. Work Status and Return to the Workforce after Coronary Artery Bypass Grafting and/or Heart Valve Surgery: A One-Year-Follow Up Study

    PubMed Central

    Fonager, Kirsten; Lundbye-Christensen, Søren; Andreasen, Jan Jesper; Futtrup, Mikkel; Christensen, Anette Luther; Ahmad, Khalil; Nørgaard, Martin Agge

    2014-01-01

    Background. Several characteristics appear to be important for estimating the likelihood of reentering the workforce after surgery. The aim of the present study was to describe work status in a two-year time period around the time of cardiac surgery and estimate the probability of returning to the workforce. Methods. We included 681 patients undergoing coronary artery bypass grafting and/or heart valve procedures from 2003 to 2007 in the North Denmark Region. We linked hospital data to data in the DREAM database which holds information of everyone receiving social benefits. Results. At the time of surgery 17.3% were allocated disability pension and 2.3% were allocated a permanent part-time benefit. Being unemployed one year before surgery reduced the likelihood of return to the workforce (RR = 0.74 (0.60–0.92)) whereas unemployment at the time of surgery had no impact on return to the workforce (RR = 0.96 (0.78–1.18)). Sickness absence before surgery reduced the likelihood of return to the workforce. Conclusion. This study found the work status before surgery to be associated with the likelihood of return to the workforce within one year after surgery. Before surgery one-fifth of the population either was allocated disability pension or received a permanent part-time benefit. PMID:25024848

  11. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

    PubMed

    Leon, Martin B; Smith, Craig R; Mack, Michael J; Makkar, Raj R; Svensson, Lars G; Kodali, Susheel K; Thourani, Vinod H; Tuzcu, E Murat; Miller, D Craig; Herrmann, Howard C; Doshi, Darshan; Cohen, David J; Pichard, Augusto D; Kapadia, Samir; Dewey, Todd; Babaliaros, Vasilis; Szeto, Wilson Y; Williams, Mathew R; Kereiakes, Dean; Zajarias, Alan; Greason, Kevin L; Whisenant, Brian K; Hodson, Robert W; Moses, Jeffrey W; Trento, Alfredo; Brown, David L; Fearon, William F; Pibarot, Philippe; Hahn, Rebecca T; Jaber, Wael A; Anderson, William N; Alu, Maria C; Webb, John G

    2016-04-28

    Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).

  12. Postoperative tricuspid regurgitation after adult congenital heart surgery is associated with adverse clinical outcomes.

    PubMed

    Lewis, Matthew J; Ginns, Jonathan N; Ye, Siqin; Chai, Paul; Quaegebeur, Jan M; Bacha, Emile; Rosenbaum, Marlon S

    2016-02-01

    Many patients with adult congenital heart disease will require cardiac surgery during their lifetime, and some will have concomitant tricuspid regurgitation. However, the optimal management of significant tricuspid regurgitation at the time of cardiac surgery remains unclear. We assessed the determinants of adverse outcomes in patients with adult congenital heart disease and moderate or greater tricuspid regurgitation undergoing cardiac surgery for non-tricuspid regurgitation-related indications. All adult patients with congenital heart disease and greater than moderate tricuspid regurgitation who underwent cardiac surgery for non-tricuspid regurgitation-related indications were included in a retrospective study at the Schneeweiss Adult Congenital Heart Center. Cohorts were defined by the type of tricuspid valve intervention at the time of surgery. The primary end point of interest was a composite of death, heart transplantation, and reoperation on the tricuspid valve. A total of 107 patients met inclusion criteria, and 17 patients (17%) reached the primary end point. A total of 68 patients (64%) underwent tricuspid valve repair, 8 patients (7%) underwent tricuspid valve replacement, and 31 patients (29%) did not have a tricuspid valve intervention. By multivariate analysis, moderate or greater postoperative tricuspid regurgitation was associated with a hazard ratio of 6.12 (1.84-20.3) for the primary end point (P = .003). In addition, failure to perform a tricuspid valve intervention at the time of surgery was associated with an odds ratio of 4.17 (1.26-14.3) for moderate or greater postoperative tricuspid regurgitation (P = .02). Moderate or greater postoperative tricuspid regurgitation was associated with an increased risk of death, transplant, or reoperation in adult patients with congenital heart disease undergoing cardiac surgery for non-tricuspid regurgitation-related indications. Concomitant tricuspid valve intervention at the time of cardiac surgery should

  13. A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries.

    PubMed

    Lazebnik, Mariya; McCartney, Leah; Popovic, Dijana; Watkins, Cynthia B; Lindstrom, Mary J; Harter, Josephine; Sewall, Sarah; Magliocco, Anthony; Booske, John H; Okoniewski, Michal; Hagness, Susan C

    2007-05-21

    The efficacy of emerging microwave breast cancer detection and treatment techniques will depend, in part, on the dielectric properties of normal breast tissue. However, knowledge of these properties at microwave frequencies has been limited due to gaps and discrepancies in previously reported small-scale studies. To address these issues, we experimentally characterized the wideband microwave-frequency dielectric properties of a large number of normal breast tissue samples obtained from breast reduction surgeries at the University of Wisconsin and University of Calgary hospitals. The dielectric spectroscopy measurements were conducted from 0.5 to 20 GHz using a precision open-ended coaxial probe. The tissue composition within the probe's sensing region was quantified in terms of percentages of adipose, fibroconnective and glandular tissues. We fit a one-pole Cole-Cole model to the complex permittivity data set obtained for each sample and determined median Cole-Cole parameters for three groups of normal breast tissues, categorized by adipose tissue content (0-30%, 31-84% and 85-100%). Our analysis of the dielectric properties data for 354 tissue samples reveals that there is a large variation in the dielectric properties of normal breast tissue due to substantial tissue heterogeneity. We observed no statistically significant difference between the within-patient and between-patient variability in the dielectric properties.

  14. Multicenter Analysis of Clinical Follow-Ups in Patients with a Star GK Cardiac Valve Replacement for More than One Year.

    PubMed

    Li, Mingwen; Xiao, Yingbin; Chen, Daozhong; Liu, Liming; Ma, Liming; Wang, Pingfan; Jia, Kui; Yang, Kai; Chen, Lin

    2016-05-18

    Star GK valves were widely used in China, and we studied the clinical follow-up results of patients with Star GK valve implants for more than one year.  Clinical data were collected from those patients who had Star GK valve implants for over one year. Patients were divided into three groups: (1) AVR group: received aortic valve replacement surgery. Based on the valve model this group was further sub-divided into two groups: 21A group, and 23A group; (2) MVR group: received mitral valve replacement surgery. Based on the valve model this group was further sub-divided into three groups: 25M group, 27M group, and 29M group; (3) DVR group: received combined replacement surgeries including AVR + MVR. According to postoperative follow-up time these patients were divided into two groups: 1-year group and 3-year group. Follow-up data were collected by telephone, outpatient visits, or correspondence. Clinical data were aggregated by professional data scientists to conduct independent analyses.  959 patients were included in the study following Star GK valve implant. Follow-up after 1 year found that thrombosis occurred in 4 cases, hemorrhage in 15 cases, left heart failure in 13 cases, paravalvular leakage in 5 cases, and death due to cardiac causes in 2 cases.  The long-term efficacy of Star GK valve implants was satisfactory with low incidence of valve-related complications, and following Star GK valve implant, valve and blood were highly compatible and blood component damage was minor. Very low incidence rate of thrombosis was observed following Star GK valve implant, however, attention should be paid to adjust the anticoagulation intensity.

  15. A 20-year study on treating childhood infective endocarditis with valve replacement in a single cardiac center in China.

    PubMed

    Xiao, Jian; Yin, Liang; Lin, Yiyun; Zhang, Yufeng; Wu, Lihui; Wang, Zhinong

    2016-07-01

    Children with infective endocarditis (IE) have to undergo valve replacement instead of valve repair in China due to severe valve damage. The present study is to review our experience on surgical treatment of children with IE in reference to the incidence, pathologic status, diagnosis, surgical strategies and outcomes. We reviewed 35 patients with a mean age of 13.7±2.2 years who were underwent valve replacement surgery for IE during the period from January 1993 to December 2013. Preoperative transthoracic echocardiographic (TTE) evaluation and transesophageal echocardiography during operation were performed in all patients. All the children underwent chart review and retrospective risk-hazard analysis. Among the patients surveyed congenital cardiac lesions were present in 15 (42.8%), rheumatic heart valve disease in 2 (5.7%) and previous heart surgery in 2 (5.7%). The median stay of intensive care unit was 6 days. Intraoperative findings showed that the endocarditis involved mostly the mitral and aortic valves (88.5%). Triple or quadruple valve involvement was found in one patient each. Ten-year freedom from IE-related death and re-intervention was 94.2% and 91.6%, respectively. Children undergoing surgery for IE frequently have advanced disease with embolic complications. Although valve replacement is not the primary option for pediatric IE, the rate of 5-year survival and freedom from re-operation was optimal prognostically. Pediatric physicians should pay attention to the common clinical features of IE so that the native valve is preserved well.

  16. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    PubMed

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  17. Ischemic Stroke in a Patient With Quadricuspid Aortic Valve and Patent Foramen Ovale.

    PubMed

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Moris, Demetrios; Tsiapras, Dimitrios; Voudris, Vassilis

    2017-08-01

    Quadricuspid aortic valve (QAV) is a rare congenital aortic valve abnormality. It is less common as compared to bicuspid or unicuspid aortic valve abnormality. QAV causes aortic regurgitation usually in the fifth to sixth decade of life. We present a rare case of a female patient with cryptogenic stroke due to a QAV and a patent foramen ovale (PFO). The patient underwent transcatheter closure of PFO, as there was no clear indication for surgery for her valve. Surgical removal remains the method of choice for the treatment of the QAV before left ventricular decompensation occurs.

  18. Permanent pacemaker lead induced severe tricuspid regurgitation in patient undergoing multiple valve surgery.

    PubMed

    Lee, Jung Hee; Kim, Tae Ho; Kim, Wook Sung

    2015-04-01

    Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

  19. Beating heart mitral valve repair with integrated ultrasound imaging

    NASA Astrophysics Data System (ADS)

    McLeod, A. Jonathan; Moore, John T.; Peters, Terry M.

    2015-03-01

    Beating heart valve therapies rely extensively on image guidance to treat patients who would be considered inoperable with conventional surgery. Mitral valve repair techniques including the MitrClip, NeoChord, and emerging transcatheter mitral valve replacement techniques rely on transesophageal echocardiography for guidance. These images are often difficult to interpret as the tool will cause shadowing artifacts that occlude tissue near the target site. Here, we integrate ultrasound imaging directly into the NeoChord device. This provides an unobstructed imaging plane that can visualize the valve lea ets as they are engaged by the device and can aid in achieving both a proper bite and spacing between the neochordae implants. A proof of concept user study in a phantom environment is performed to provide a proof of concept for this device.

  20. Finite element analysis for edge-to-edge technique to treat post-mitral valve repair systolic anterior motion.

    PubMed

    Zhong, Qi; Zeng, Wenhua; Huang, Xiaoyang; Zhao, Xiaojia

    2014-01-01

    Systolic anterior motion of the mitral valve is an uncommon complication of mitral valve repair, which requires immediate supplementary surgical action. Edge-to-edge suture is considered as an effective technique to treat post-mitral valve repair systolic anterior motion by clinical researchers. However, the fundamentals and quantitative analysis are vacant to validate the effectiveness of the additional edge-to-edge surgery to repair systolic anterior motion. In the present work, finite element models were developed to simulate a specific clinical surgery for patients with posterior leaflet prolapse, so as to analyze the edge-to-edge technique quantificationally. The simulated surgery procedure concluded several actions such as quadrangular resection, mitral annuloplasty and edge-to-edge suture. And the simulated results were compared with echocardiography and measurement data of the patients under the mitral valve surgery, which shows good agreement. The leaflets model with additional edge-to-edge suture has a shorter mismatch length than that of the model merely under quadrangular resection and mitral annuloplasty actions at systole, which assures a better coaptation status. The stress on the leaflets after edge-to-edge suture is lessened as well.

  1. Mitral annular longitudinal function preservation after mitral valve repair: the MARTE study.

    PubMed

    Lisi, M; Ballo, P; Cameli, M; Gandolfo, F; Galderisi, M; Chiavarelli, M; Henein, M Y; Mondillo, S

    2012-05-31

    In patients with chronic mitral regurgitation (MR), undergoing surgical mitral valve repair, current Guidelines only recommend standard echocardiographic indices i.e. left ventricular (LV) ejection fraction (EF), and LV end-systolic and end-diastolic diameters as preoperative variables. However LV EF is often preserved until advanced stages of the valve disease. Aim of this study was to evaluate changes in LV systolic longitudinal function, 3 months after mitral valve repair in patients with chronic degenerative MR and normal preoperative EF. We measured M-mode mitral lateral annulus systolic excursion (MAPSE) and Tissue Doppler (TD) peak systolic annular velocity (S(m)) in 31 patients with moderate to severe MR and normal EF (59.9 ± 4.7%) candidates for mitral valve repair, preoperatively and 3 months after surgery. After mitral valve repair, S(m) increased from 7.8 ± 1.4 to 9.6 ± 2.2 cm/s (p<0.0001) and MAPSE increased from 1.33 ± 0.26 to 1.55 ± 0.25 cm (p=0.0013). EF decreased from 59.9 ± 4.7 to 51.3 ± 5.9% (p<0.0001). As expected, LV diameters and volumes, wall thicknesses, midwall fractional shortening (mFS), and left atrial (LA) size were all reduced after surgery. This study suggests that assessment of LV long axis systolic velocity and amplitude of excursion by echocardiography is more sensitive than simple determination of EF for revealing the beneficial impact of MR surgery on overall systolic function. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  2. Cardiac Surgery in Patients Infected with Human Immunodeficiency Virus

    PubMed Central

    Abad, Cipriano; Cárdenes, Miguel Angel; Jiménez, Pedro Conrado; Armas, Mario-Vicente; Betancor, Pedro

    2000-01-01

    From January 1991 through December 1999, 5 consecutive patients who were infected with human immunodeficiency virus presented in need of cardiac surgery. All were men; the median age was 44 years. Two of them presented with mitral and aortic infectious valve endocarditis, 1 with tricuspid endocarditis, 1 with prosthetic valve endocarditis, and 1 with pericarditis and pericardial tamponade. Under cardiopulmonary bypass, the 4 patients with endocarditis underwent these procedures: mitral and aortic valve replacement (2), tricuspid valve replacement (1), and aortic valve replacement (reoperation) and concomitant repair of a mycotic ascending aortic aneurysm (1). In the patient who had pericardial effusion, subxifoid pericardiostomy and drainage were performed, and a pericardial window was created. There was no intraoperative mortality. The patient with pericardial effusion died 8 days after surgery; he was in septic shock and had multiple organ failure. Two deaths occurred at 2 and 63 months, due to hemoptysis and sudden death, respectively. The 2 patients who underwent double valve replacement are alive and in good condition after a median follow-up of 71 months. Cardiac surgery is indicated in selected patients infected by the human immunodeficiency virus. These patients are frequently drug abusers or homosexual. Valvular endocarditis is the most common finding. Hospital morbidity and mortality rates are higher than usual in this group of patients. PMID:11198308

  3. Aortic root surgery in the United States: a report from the Society of Thoracic Surgeons database.

    PubMed

    Stamou, Sotiris C; Williams, Mathew L; Gunn, Tyler M; Hagberg, Robert C; Lobdell, Kevin W; Kouchoukos, Nicholas T

    2015-01-01

    The purpose of the present study was to evaluate the early clinical outcomes of aortic root surgery in the United States. The Society of Thoracic Surgeons database was queried to identify all patients who had undergone aortic root replacement from 2004 to early 2010 (n = 13,743). The median age was 58 years (range, 18-96); 3961 were women (29%) and 12,059 were white (88%). The different procedures included placement of a mechanical valve conduit (n = 4718, 34%), stented pericardial (n = 879, 6.4%) or porcine (n = 478, 3.5%) bioprosthesis, stentless root (n = 4309, 31%), homograft (n = 498, 3.6%), and valve sparing root replacement (n = 1918, 14%). The median number of aortic root surgeries per site was 2, and only 5% of sites performed >16 aortic root surgeries annually. An increased trend to use biostented (porcine or pericardial) valves during the study period (7% in 2004 vs 14% in 2009). The operative (raw) mortality was greater among the patients with aortic stenosis (6.2%) who had undergone aortic root replacement, independent of age. Mortality was greater in patients who had undergone concomitant valve or coronary artery bypass grafting or valve surgery (21%). The lowest operative mortality was observed in patients who had undergone aortic valve sparing procedures (1.9%). Most cardiac centers performed aortic root surgery in small volumes. The unadjusted operative mortality was greater for patients >80 years old and those with aortic stenosis, regardless of age. Valve sparing root surgery was associated with the lowest mortality. A trend was seen toward an increased use of stented tissue valves from 2004 to 2009. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Turbulence downstream of subcoronary stentless and stented aortic valves.

    PubMed

    Funder, Jonas Amstrup; Frost, Markus Winther; Wierup, Per; Klaaborg, Kaj-Erik; Hjortdal, Vibeke; Nygaard, Hans; Hasenkam, J Michael

    2011-08-11

    Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Successful surgical treatment of mitral valve stenosis in a dog.

    PubMed

    Borenstein, N; Daniel, P; Behr, L; Pouchelon, J L; Carbognani, D; Pierrel, A; Macabet, V; Lacheze, A; Jamin, G; Carlos, C; Chetboul, V; Laborde, F

    2004-01-01

    To report the successful surgical management (open mitral commissurotomy, OMC) of mitral stenosis (MS), incorporating heart-beating cardiopulmonary bypass (CPB), in a 1-year-old dog. Clinical case. One-year-old Cairn Terrier with MS. Diagnosis of MS was confirmed by means of 2-dimensional, continuous-wave and color-flow Doppler echocardiography. Surgery was performed through a left intercostal thoracotomy. CPB was initiated and the heart was kept beating. The fused commissures of the mitral valve were incised to free the cusps of the valve. Left intercostal thoracotomy allowed easy observation of the mitral orifice during heart-beating OMC. Persistent bleeding from the atriotomy site required a second surgical procedure after which the dog had an uneventful recovery. Echocardiography at 2 weeks and 1 year postoperatively indicated substantial improvement in left ventricular filling (pressure half-time=187 ms before surgery, 105 ms [2 weeks] and 110 ms [1 year] after surgery). Enlargement of the left atrium resolved; however, moderate mitral valve regurgitation was still present. MS can be successfully treated by OMC, facilitated by use of CPB. Substantial improvement in cardiac function was evident by ultrasound and Doppler examination postoperatively. OMC under heart-beating CPB should be considered for the treatment of MS in the dog.

  6. The great debate series: surgical treatment of aortic valve abnormalities in children.

    PubMed

    d'Udekem, Yves; Tweddell, James S; Karl, Tom R

    2018-05-01

    This article is the latest in an EJCTS series entitled 'The Great Debates'. We have chosen the topic of aortic valve (AoV) surgery in children, with a focus on infants and neonates. The topic was selected due to the significant challenges that AoV problems in the young may present to the surgical team. There are many areas of active controversy, despite the vast accumulated world experience. We have tried to incorporate many of these issues in the questions posed, not claiming to be all-inclusive. The individuals invited to this debate are experts in paediatric valve surgery, with broad and successful clinical experiences on multiple continents. We hope that the facts and opinions presented in this debate will generate interest and discussion and perhaps prove useful in decision-making for future complex valve cases.

  7. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    PubMed

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Redo surgery risk in patients with cardiac prosthetic valve dysfunction

    PubMed Central

    Maciejewski, Marek; Piestrzeniewicz, Katarzyna; Bielecka-Dąbrowa, Agata; Piechowiak, Monika; Jaszewski, Ryszard

    2011-01-01

    Introduction The aim of the study was to analyse the risk factors of early and late mortality in patients undergoing the first reoperation for prosthetic valve dysfunction. Material and methods A retrospective observational study was performed in 194 consecutive patients (M = 75, F = 119; mean age 53.2 ±11 years) with a mechanical prosthetic valve (n = 103 cases; 53%) or bioprosthesis (91; 47%). Univariate and multivariate Cox statistical analysis was performed to determine risk factors of early and late mortality. Results The overall early mortality was 18.6%: 31.4% in patients with symptoms of NYHA functional class III-IV and 3.4% in pts in NYHA class I-II. Multivariate analysis identified symptoms of NYHA class III-IV and endocarditis as independent predictors of early mortality. The overall late mortality (> 30 days) was 8.2% (0.62% year/patient). Multivariate analysis identified age at the time of reoperation as a strong independent predictor of late mortality. Conclusions Reoperation in patients with prosthetic valves, performed urgently, especially in patients with symptoms of NYHA class III-IV or in the case of endocarditis, bears a high mortality rate. Risk of planned reoperation, mostly in patients with symptoms of NYHA class I-II, does not differ from the risk of the first operation. PMID:22291767

  9. One-year outcomes after rapid-deployment aortic valve replacement.

    PubMed

    Young, Christopher; Laufer, Günther; Kocher, Alfred; Solinas, Marco; Alamanni, Francesco; Polvani, Gianluca; Podesser, Bruno K; Aramendi, Jose Ignacio; Arribas, Jose; Bouchot, Olivier; Livi, Ugolino; Massetti, Massimo; Terp, Kim; Giot, Christophe; Glauber, Mattia

    2018-02-01

    The goals of rapid-deployment aortic valve replacement include facilitation of minimally invasive surgery and reduced aortic crossclamp time. We report the short-term outcomes of a series of 493 patients undergoing rapid-deployment aortic valve replacement with the EDWARDS INTUITY valve system (Edwards Lifesciences, LLC, Irvine, Calif). Assessing Standard oF Care and Clinical Outcomes UsiNg the EDWARDS INTUITY VAlve SysTem in a European multI-center, Active, pOst-market surveillaNce Study was a prospective, multicenter (n = 26) European registry designed to evaluate the safety and performance of the valve system. During rapid-deployment aortic valve replacement, device technical success and crossclamp time were assessed. Procedural outcomes, hemodynamic performance, and various adverse events and clinical outcomes were evaluated up to 2 years. Between 2012 and 2014, 493 of 517 enrolled patients successfully received implants with the study valve (95.4% technical success). Mean crossclamp times for 163 full sternotomies, 128 mini-upper sternotomies, and 36 right anterior thoracotomies isolated aortic valve replacements were 47.3, 52.0, and 73.3 minutes, respectively. Mean follow-up was 1.8 years, with 870 total patient-years of follow-up. Mean effective orifice area increased from 0.72 (baseline) to 1.88 cm 2 , and mean pressure gradient decreased from 47.6 to 9.6 mm Hg (1 year). Mean effective orifice area index increased (0.39-1.01 cm 2 /m 2 ), and 28 of 287 patients (9.8%) exhibited severe prosthesis-patient mismatch at 1 year. After 1 year, 68.1% and 21.7% of patients were in New York Heart Association class I and II, respectively. Freedom from death, major bleeding, major perivalvular leak, reoperation, and device explant at 1 year were 0.935, 0.939, 0.976, 0.975, and 0.983, respectively. These results demonstrate commendable safety and performance of the test valve system over the short term in a broad European setting. Copyright © 2017 The

  10. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    PubMed

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p < 0.0001) during a median follow-up period of 24.0 and 35.5 months, respectively (p = 0.03). For patients with BJV valves, the incidence of IE was not different between surgical and catheter-based valve implantation (p = 0.83). There was a higher incidence of endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Long-term echocardiographic follow-up of untreated 2+ functional tricuspid regurgitation in patients undergoing mitral valve surgery†

    PubMed Central

    Kusajima, Kunio; Fujita, Tomoyuki; Hata, Hiroki; Shimahara, Yusuke; Miura, Sayaka; Kobayashi, Junjiro

    2016-01-01

    OBJECTIVES Concomitant tricuspid valve surgery with mitral valve surgery is recommended for patients with severe functional tricuspid regurgitation (TR). However, the treatment for 2+ TR (mild TR) remains controversial. Here, we evaluated the long-term results of untreated 2+ TR in patients undergoing mitral valve surgery. METHODS We retrospectively reviewed the records of 96 patients with untreated 2+ TR among 885 patients who underwent mitral valve surgery from 2003 to 2010. Exclusion criteria were tricuspid valve surgery (TVS), emergency surgery, primary TR and pacemaker lead through the tricuspid valve. We assessed survival and freedom from heart failure. The freedom from 3+ (moderate) or 4+ (severe) TR was investigated by echocardiographic data at pre- and postoperative week 1, then at 1, 3, 5, 7 and 10 postoperative years, which were compared with those in patients who had 2+ TR preoperatively and underwent concomitant TVS in the same period (n = 47). RESULTS The mean follow-up was 7.1 ± 2.7 years. There was no 30-day mortality. The survival rate was 97.5% at 5 years and 87.5% at 10 years. The independent risk factors for mortality were age (OR 1.2, P = 0.03) and left ventricular ejection fraction (OR 0.9, P = 0.03). Untreated 2+ TR improved transiently within the first postoperative year (P < 0.001), but progressed again in the mid- to long term. Freedom from ≥3+ TR was 64.2% at 5 years and 46.7% at 10 years, which was significantly lower than that from ≥3+ TR in patients who underwent concomitant TVS (P = 0.006). The independent risk factors for TR progression (≥3 + TR) were age (OR 1.1, P = 0.005), atrial fibrillation (OR 2.2, P = 0.04) and tricuspid annular diameter (TAD) index (mm/m2; OR 1.1, P = 0.02). Receiver operating characteristic curves showed that the optimal TAD index cut-off value was 21.0 for long-term survival [area under the curve (AUC) = 0.72] and 21.2 for TR progression (AUC = 0.64). CONCLUSIONS Although untreated, 2+ TR

  12. Health care-associated native valve endocarditis: importance of non-nosocomial acquisition.

    PubMed

    Benito, Natividad; Miró, José M; de Lazzari, Elisa; Cabell, Christopher H; del Río, Ana; Altclas, Javier; Commerford, Patrick; Delahaye, Francois; Dragulescu, Stefan; Giamarellou, Helen; Habib, Gilbert; Kamarulzaman, Adeeba; Kumar, A Sampath; Nacinovich, Francisco M; Suter, Fredy; Tribouilloy, Christophe; Venugopal, Krishnan; Moreno, Asuncion; Fowler, Vance G

    2009-05-05

    The clinical profile and outcome of nosocomial and non-nosocomial health care-associated native valve endocarditis are not well defined. To compare the characteristics and outcomes of community-associated and nosocomial and non-nosocomial health care-associated native valve endocarditis. Prospective cohort study. 61 hospitals in 28 countries. Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the ICE-PCS (International Collaboration on Endocarditis Prospective Cohort Study) from June 2000 to August 2005. Clinical and echocardiographic findings, microbiology, complications, and mortality. Health care-associated native valve endocarditis was present in 557 (34%) of 1622 patients (303 with nosocomial infection [54%] and 254 with non-nosocomial infection [46%]). Staphylococcus aureus was the most common cause of health care-associated infection (nosocomial, 47%; non-nosocomial, 42%; P = 0.30); a high proportion of patients had methicillin-resistant S. aureus (nosocomial, 57%; non-nosocomial, 41%; P = 0.014). Fewer patients with health care-associated native valve endocarditis had cardiac surgery (41% vs. 51% of community-associated cases; P < 0.001), but more of the former patients died (25% vs. 13%; P < 0.001). Multivariable analysis confirmed greater mortality associated with health care-associated native valve endocarditis (incidence risk ratio, 1.28 [95% CI, 1.02 to 1.59]). Patients were treated at hospitals with cardiac surgery programs. The results may not be generalizable to patients receiving care in other types of facilities or to those with prosthetic valves or past injection drug use. More than one third of cases of native valve endocarditis in non-injection drug users involve contact with health care, and non-nosocomial infection is common, especially in the United States. Clinicians should recognize that outpatients with extensive out-of-hospital health care contacts who develop endocarditis have

  13. Prognostic Implications of Raphe in Bicuspid Aortic Valve Anatomy.

    PubMed

    Kong, William K F; Delgado, Victoria; Poh, Kian Keong; Regeer, Madelien V; Ng, Arnold C T; McCormack, Louise; Yeo, Tiong Cheng; Shanks, Miriam; Parent, Sarah; Enache, Roxana; Popescu, Bogdan A; Liang, Michael; Yip, James W; Ma, Lawrence C W; Kamperidis, Vasileios; van Rosendael, Philippe J; van der Velde, Enno T; Ajmone Marsan, Nina; Bax, Jeroen J

    2017-03-01

    Little is known about the association between bicuspid aortic valve (BAV) morphologic findings and the degree of valvular dysfunction, presence of aortopathy, and complications, including aortic valve surgery, aortic dissection, and all-cause mortality. To investigate the association between BAV morphologic findings (raphe vs nonraphe) and the degree of valve dysfunction, presence of aortopathy, and prognosis (including need for aortic valve surgery, aortic dissection, and all-cause mortality). In this large international multicenter registry of patients with BAV treated at tertiary referral centers, 2118 patients with BAV were evaluated. Patients referred for echocardiography from June 1, 1991, through November 31, 2015, were included in the study. Clinical and echocardiographic data were analyzed retrospectively. The morphologic BAV findings were categorized according to the Sievers and Schmidtke classification. Aortic valve function was divided into normal, regurgitation, or stenosis. Patterns of BAV aortopathy included the following: type 1, dilation of the ascending aorta and aortic root; type 2, isolated dilation of the ascending aorta; and type 3, isolated dilation of the sinus of Valsalva and/or sinotubular junction. Association between the presence and location of raphe and the risk of significant (moderate and severe) aortic valve dysfunction and aortic dilation and/or dissection. Of the 2118 patients (mean [SD] age, 47 [18] years; 1525 [72.0%] male), 1881 (88.8%) had BAV with fusion raphe, whereas 237 (11.2%) had BAV without raphe. Bicuspid aortic valves with raphe had a significantly higher prevalence of valve dysfunction, with a significantly higher frequency of aortic regurgitation (622 [33.1%] vs 57 [24.1%], P < .001) and aortic stenosis (728 [38.7%] vs 51 [21.5%], P < .001). Furthermore, aortic valve replacement event rates were significantly higher among patients with BAV with raphe (364 [19.9%] at 1 year, 393 [21.4%] at 2 years, and 447

  14. [Impact of microwave dealing with the cutting surface on the hepatocellular carcinoma recurrence after hepatectomy].

    PubMed

    Wu, Zhengshan; Wang, Xing; Wang, Dong; Fan, Ye; Li, Donghua; Kong, Lianbao; Wang, Xuehao; Wang, Ke

    2015-12-01

    To explore the impact of microwave dealing with cutting surface on perioperative liver function recovery and recurrence and metastasis after hepatectomy for HCC. Clinical data of 133 patients with HCC from March 2009 to November 2010 were retrospectively analyzed. They were divided into the conventional surgery group (66 cases) and microwave treatment group (67 cases). A domestic ECO-100 microwave knife was inserted into the liver cutting surface 0.5 cm from the cutting edge, and repeated multi-point burning with an average time of 25 minutes in the microwave treatment group. Then the perioperative liver function recovery and recurrence and metastasis in the two groups were compared. The operation time of conventional surgery group was (158.0 ± 31.0) minutes, and that of microwave treatment group was significantly longer (181.0 ± 28.0) minutes (P=0.027). There were no significant differences in the liver function recovery between the two groups (P>0.05). There were 6 cases of recurrence and metastasis after 6 months and 9 cases after 12 months in the microwave treatment group, while there were 15 cases of recurrence and metastasis after 6 months and 20 cases after 12 months in the conventional surgery group, showing a significant difference (P=0.034 and 0.022, respectively). Microwave dealing with the cutting surface has no significant effect on perioperative liver function recovery in hepatectomy. However, microwave treatment can reduce the in situ recurrence in HCC patients within the first year after surgery, indicating a good clinical application value.

  15. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    PubMed

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P <0.001) and an increase in valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P <0.001). No procedural complications were reported. BVF can be performed safely in small surgical valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  16. Evaluating the effect of three-dimensional visualization on force application and performance time during robotics-assisted mitral valve repair.

    PubMed

    Currie, Maria E; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W A; Patel, Rajni; Peters, Terry; Kiaii, Bob B

    2013-01-01

    The purpose of this study was to determine the effect of three-dimensional (3D) binocular, stereoscopic, and two-dimensional (2D) monocular visualization on robotics-assisted mitral valve annuloplasty versus conventional techniques in an ex vivo animal model. In addition, we sought to determine whether these effects were consistent between novices and experts in robotics-assisted cardiac surgery. A cardiac surgery test-bed was constructed to measure forces applied during mitral valve annuloplasty. Sutures were passed through the porcine mitral valve annulus by the participants with different levels of experience in robotics-assisted surgery and tied in place using both robotics-assisted and conventional surgery techniques. The mean time for both the experts and the novices using 3D visualization was significantly less than that required using 2D vision (P < 0.001). However, there was no significant difference in the maximum force applied by the novices to the mitral valve during suturing (P = 0.7) and suture tying (P = 0.6) using either 2D or 3D visualization. The mean time required and forces applied by both the experts and the novices were significantly less using the conventional surgical technique than when using the robotic system with either 2D or 3D vision (P < 0.001). Despite high-quality binocular images, both the experts and the novices applied significantly more force to the cardiac tissue during 3D robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery.

  17. Management of mitral regurgitation in Marfan syndrome: Outcomes of valve repair versus replacement and comparison with myxomatous mitral valve disease.

    PubMed

    Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M

    2014-09-01

    The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Ischemic Stroke in a Patient With Quadricuspid Aortic Valve and Patent Foramen Ovale

    PubMed Central

    Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Moris, Demetrios; Tsiapras, Dimitrios; Voudris, Vassilis

    2017-01-01

    Quadricuspid aortic valve (QAV) is a rare congenital aortic valve abnormality. It is less common as compared to bicuspid or unicuspid aortic valve abnormality. QAV causes aortic regurgitation usually in the fifth to sixth decade of life. We present a rare case of a female patient with cryptogenic stroke due to a QAV and a patent foramen ovale (PFO). The patient underwent transcatheter closure of PFO, as there was no clear indication for surgery for her valve. Surgical removal remains the method of choice for the treatment of the QAV before left ventricular decompensation occurs. PMID:28868103

  19. A global perspective on mechanical prosthetic heart valve thrombosis: Diagnostic and therapeutic challenges

    PubMed Central

    Gürsoy, Mustafa Ozan; Kalçık, Macit; Yesin, Mahmut; Karakoyun, Süleyman; Bayam, Emrah; Gündüz, Sabahattin; Özkan, Mehmet

    2016-01-01

    Prosthetic valve thrombosis is one of the major causes of primary valve failure, which can be life-threatening. Multimodality imaging is necessary for determination of leaflet immobilization, cause of underlying pathology (thrombus versus pannus or both), and whether thrombolytic therapy attempt in the patient would be successful or surgery is needed. Current guidelines for the management of prosthetic valve thrombosis lack definitive class I recommendations due to lack of randomized controlled trials, and usually leave the choice of treatment to the clinician’s experience. In this review, we aimed to summarize the pathogenesis, diagnosis, and management of mechanical prosthetic valve thrombosis. PMID:28005024

  20. Percutaneous transluminal alcohol septal myocardial ablation after aortic valve replacement

    NASA Technical Reports Server (NTRS)

    Sitges, M.; Kapadia, S.; Rubin, D. N.; Thomas, J. D.; Tuzcu, M. E.; Lever, H. M.

    2001-01-01

    When left ventricular outflow tract obstruction develops after aortic valve replacement, few treatment choices have been available until now. We present a patient with prior aortic valve replacement who developed left ventricle outflow tract obstruction that was successfully treated with a percutaneous transcoronary myocardial septal alcohol ablation. This technique is a useful tool for the treatment of obstructive hypertrophic cardiomyopathy, especially in those patients with prior heart surgery. Copyright 2001 Wiley-Liss, Inc.

  1. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  2. Reoperation for non-structural valvular dysfunction caused by pannus ingrowth in aortic valve prosthesis.

    PubMed

    Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk

    2013-07-01

    The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.

  3. Haemodynamic results of replacement of mitral and aortic valves with autologous fascia lata prostheses

    PubMed Central

    Talavlikar, P. H.; Walbaum, P. R.; Kitchin, A. H.

    1973-01-01

    Twelve patients undergoing aortic and 28 undergoing mitral valve replacement with autologous fascia lata valves were studied before and six months after surgery. One aortic and 10 mitral valves were found to be significantly incompetent. Of the incompetent mitral valves, two appeared to have perivalvular leaks. Six of the remainder were associated with abnormal ventricular filling patterns. Valve failure was much less common when the design was modified to provide a loose cusp structure; out of 12 such valves none was incompetent. Transvalvular gradients persist with fascial valves though they are lower than with most mechanical prostheses. Ventricular function was greatly improved in successful aortic replacement but remained impaired in the case of mitral replacement. Valve failure appeared to be associated with, or accelerated by, haemodynamic stress rather than due to inevitable degenerative pathological processes. PMID:4731108

  4. Open-heart surgery using a centrifugal pump: a case of hereditary spherocytosis.

    PubMed

    Matsuzaki, Yuichi; Tomioka, Hideyuki; Saso, Masaki; Azuma, Takashi; Saito, Satoshi; Aomi, Shigeyuki; Yamazaki, Kenji

    2016-08-26

    Hereditary spherocytosis is a genetic, frequently familial hemolytic blood disease characterized by varying degrees of hemolytic anemia, splenomegaly, and jaundice. There are few reports on adult open-heart surgery for patients with hereditary spherocytosis. We report a rare case of an adult open-heart surgery associated with hereditary spherocytosis. A 63-year-old man was admitted for congestive heart failure due to bicuspid aortic valve, aortic valve regurgitation, and sinus of subaortic aneurysm. The family history, the microscopic findings of the blood smear, and the characteristic osmotic fragility confirmed the diagnosis of hereditary spherocytosis. Furthermore, splenectomy had not been undertaken preoperatively. The patient underwent a successful operation by means of a centrifugal pump. Haptoglobin was used during the cardiopulmonary bypass, and a biological valve was selected to prevent hemolysis. No significant hemolysis occurred intraoperatively or postoperatively. There are no previous reports of patients with hereditary spherocytosis, and bicuspid aortic valve. We have successfully performed an adult open-heart surgery using a centrifugal pump in an adult patient suffering from hereditary spherocytosis and bicuspid aortic valve.

  5. Outcome of aortic valve replacement for active infective endocarditis in patients on chronic hemodialysis.

    PubMed

    Dohmen, Pascal M; Binner, Christian; Mende, Meinhart; Bakhtiary, Farhad; Etz, Christian; Pfannmüller, Bettina; Davierwala, Piroze; Borger, Michael A; Misfeld, Martin; Mohr, Friedrich W

    2015-02-01

    The high risk of morbidity and mortality for patients on hemodialysis who are undergoing cardiac surgery is increased for those with active infective endocarditis (AIE). This retrospective observational single-center study evaluated the impact of chronic hemodialysis on the outcome of aortic valve replacement in patients with aortic AIE. Data were retrospectively collected for consecutive patients undergoing aortic valve surgery for AIE diagnosed according to modified Duke criteria between October 1994 and January 2011. Characteristics and outcomes of patients receiving preoperative chronic hemodialysis were analyzed. Aortic valve AIE was present in 992 patients. Forty-five (4.5%) of the aortic valve AIE patients were receiving long-term hemodialysis preoperatively, 19 of whom (42.2%) had diabetes mellitus. Mean logistic EuroSCORE was 64.2% ± 32.2%. Twenty-four preoperative septic emboli were found in 15 patients. Results of microbiologic cultures were positive in 36 patients, with the major causative organisms identified as Staphylococcus aureus (n = 17) and Enterococcus faecalis (n = 10). Isolated aortic valve replacement was performed in 19 patients (42.2%), and 26 patients (57.8%) underwent concomitant procedures. The mean follow-up was 5.3 ± 5.2 years (range, 0.1 to 17.1 years). Postoperative complications occurred in 30 patients (66.7%). Nineteen patients (42.2%) died within 30 days of surgery, which in 8 patients was attributable to a cardiac cause. In patients receiving chronic hemodialysis who undergo aortic valve replacement for acute AIE, postoperative mortality is high, especially in patients undergoing aortic root replacement or culture-negative AIE. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    PubMed

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  7. A comparison between minimized extracorporeal circuits and conventional extracorporeal circuits in patients undergoing aortic valve surgery: is 'minimally invasive extracorporeal circulation' just low prime or closed loop perfusion ?

    PubMed

    Starinieri, Pascal; Declercq, Peter E; Robic, Boris; Yilmaz, Alaaddin; Van Tornout, Michiel; Dubois, Jasperina; Mees, Urbain; Hendrikx, Marc

    2017-07-01

    Even though results have been encouraging, an unequivocal conclusion on the beneficial effect of minimally invasive extracorporeal circulation (MiECC) in patients undergoing aortic valve surgery cannot be derived from previous publications. Long-term outcomes are rarely reported and a significant decrease in operative mortality has not been shown. Most studies have a limited number of patients and are underpowered. They merely report on short-term results of a heterogeneous intraoperative group using different types of ECC system in aortic valve surgery. The aim of the present study was to determine whether MiECC systems are more beneficial than conventional extracorporeal systems (CECC) with regard to mortality, hospital stay and inflammation and with only haemodilution and blood-air interface as differences. We retrospectively analysed data regarding mortality, hospital stay and inflammation in patients undergoing isolated aortic valve surgery. Forty patients were divided into two groups based on the type of extracorporeal system used; conventional (n=20) or MiECC (n=20). Perioperative blood product requirements were significantly lower in the MiECC group (MiECC: 0.2±0.5 units vs CECC: 0.9±1.2 units, p=0.004). No differences were seen postoperatively regarding mortality (5% vs 5%, p=0.99), total length of hospital stay (10.6±7.2 days (MiECC) vs 12.1±5.9 days (CECC), p=0.39) or inflammation markers (CRP: MiECC: 7.09±13.62 mg/L vs CECC: 3.4±3.2 mg/L, p=0.89). MiECC provides circulatory support that is equally safe and feasible as conventional extracorporeal circuits. No differences in mortality, hospital stay or inflammation markers were observed.

  8. Learning curve analysis of mitral valve repair using telemanipulative technology.

    PubMed

    Charland, Patrick J; Robbins, Tom; Rodriguez, Evilio; Nifong, Wiley L; Chitwood, Randolph W

    2011-08-01

    To determine if the time required to perform mitral valve repairs using telemanipulation technology decreases with experience and how that decrease is influenced by patient and procedure variables. A single-center retrospective review was conducted using perioperative and outcomes data collected contemporaneously on 458 mitral valve repair surgeries using telemanipulative technology. A regression model was constructed to assess learning with this technology and predict total robot time using multiple predictive variables. Statistical analysis was used to determine if models were significantly useful, to rule out correlation between predictor variables, and to identify terms that did not contribute to the prediction of total robot time. We found a statistically significant learning curve (P < .01). The institutional learning percentage∗ derived from total robot times† for the first 458 recorded cases of mitral valve repair using telemanipulative technology is 95% (R(2) = .40). More than one third of the variability in total robot time can be explained through our model using the following variables: type of repair (chordal procedures, ablations, and leaflet resections), band size, use of clips alone in band implantation, and the presence of a fellow at bedside (P < .01). Learning in mitral valve repair surgery using telemanipulative technology occurs at the East Carolina Heart Institute according to a logarithmic curve, with a learning percentage of 95%. From our regression output, we can make an approximate prediction of total robot time using an additive model. These metrics can be used by programs for benchmarking to manage the implementation of this new technology, as well as for capacity planning, scheduling, and capital budget analysis. Copyright © 2011 The American Association for Thoracic Surgery. All rights reserved.

  9. Surgery for atrial fibrillation.

    PubMed

    Viganò, M; Graffigna, A; Ressia, L; Minzioni, G; Pagani, F; Aiello, M; Gazzoli, F

    1996-01-01

    The mechanisms of atrial fibrillation arc multiple reentry circuits spinning around the atrial surface, and these baffle any attempt to direct surgical interruption. The purpose of this article is to report the surgical experience in the treatment of isolated and concomitant atrial fibrillation at the Cardiac Surgical Institute of the University of Pavia. In cases of atrial fibrillation secondary to mitral/valve disease, surgical isolation of the left atrium at the time of mitral valve surgery can prevent atrial fibrillation from involving the right atrium, which can exert its diastolic pump function on the right ventricle. Left atrial isolation was performed on 205 patients at the time of mitral valve surgery. Atrial partitioning ("maze operation") creates straight and blind atrial alleys so that non-recentry circuits can take place. Five patients underwent this procedure. In eight-cases of atrial fibrillation secondary to atrial septal defect, the adult patients with atrial septal defect and chronic or paroxysmal atrial fibrillation underwent surgical isolation of the right atrium associated which surgical correction of the defect, in order to let sinus rhythm govern the left atrium and the ventricles. "Lone" atrial fibrillation occurs in hearts with no detectable organic disease. Bi-atrial isolation with creation of an atrial septal internodal "corridor" was performed on 14 patients. In cases of atrial fibrillation secondary to mitral valve disease, left atrial isolation was performed on 205 patients at the time of mitral valve surgery with an overall sinus rhythm recovery of 44%. In the same period, sinus rhythm was recovered and persisted in only 19% of 252 patients who underwent mitral valve replacement along (P < 0.001). Sinus rhythm was less likely to recover in patients with right atriomegaly requiring tricuspid valve annuloplasty: 59% vs 84% (P < 0.001). Restoration of the right atrial function raised the cardiac index from 2.25 +/- 0.55 1/min per m2

  10. ANMCO/SIC/SICI-GISE/SICCH Executive Summary of Consensus Document on Risk Stratification in elderly patients with aortic stenosis before surgery or transcatheter aortic valve replacement

    PubMed Central

    Gulizia, Michele Massimo; Baldasseroni, Samuele; Bedogni, Francesco; Cioffi, Giovanni; Indolfi, Ciro; Romeo, Francesco; Murrone, Adriano; Musumeci, Francesco; Parolari, Alessandro; Patanè, Leonardo; Pino, Paolo Giuseppe; Mongiardo, Annalisa; Spaccarotella, Carmen; Di Bartolomeo, Roberto; Musumeci, Giuseppe

    2017-01-01

    Abstract Aortic stenosis is one of the most frequent valvular diseases in developed countries, and its impact on public health resources and assistance is increasing. A substantial proportion of elderly people with severe aortic stenosis is not eligible to surgery because of the advanced age, frailty, and multiple co-morbidities. Transcatheter aortic valve implantation (TAVI) enables the treatment of very elderly patients at high or prohibitive surgical risk considered ineligible for surgery and with an acceptable life expectancy. However, a significant percentage of patients die or show no improvement in quality of life (QOL) in the follow-up. In the decision-making process, it is important to determine: (i) whether and how much frailty of the patient influences the risk of procedures; (ii) how the QOL and the individual patient’s survival are influenced by aortic valve disease or from other associated conditions; and (iii) whether a geriatric specialist intervention to evaluate and correct frailty or other diseases with their potential or already manifest disabilities can improve the outcome of surgery or TAVI. Consequently, in addition to risk stratification with conventional tools, a number of factors including multi-morbidity, disability, frailty, and cognitive function should be considered, in order to assess the expected benefit of both surgery and TAVI. The pre-operative optimization through a multidisciplinary approach with a Heart Team can counteract the multiple damage (cardiac, neurological, muscular, respiratory, and kidney) that can potentially aggravate the reduced physiological reserves characteristic of frailty. The systematic application in clinical practice of multidimensional assessment instruments of frailty and cognitive function in the screening and the adoption of specific care pathways should facilitate this task. PMID:28751850

  11. Factors influencing mortality after bioprosthetic valve replacement; a midterm outcome.

    PubMed

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population.

  12. Rheumatic mitral valve stenosis mimicking advanced lung cancer.

    PubMed

    von Lueder, Thomas; Steine, Kjetil; Nerdrum, Tone; Steen, Torkel; Bay, Dag; Humerfelt, Sjur; Atar, Dan

    2007-09-01

    This report describes a patient with a perihilar mass and mediastinal lymphadenopathy mimicking advanced lung cancer. The patient, a 45-year old regular smoker, was admitted to hospital for dyspnea and tachyarrhythmia, and during hospitalization he was diagnosed with severe rheumatic mitral valve stenosis (MVS) and aortic regurgitation as well as pulmonary venous hypertension. Surgical valve replacement and removal of an atrial thrombus was delayed considerably by diagnostic work-up for suspected malignancy. After cardiac surgery had been performed, recovery was uneventful. On follow-up 1 year later, echocardiography showed well-functioning prosthetic mitral and aortic valves, and normal findings on chest X-ray. Perihilar masses and mediastinal lymphadenopathy presented in this case constitute infrequent yet established findings in MVS, resulting from pulmonary venous congestion and hypertension, and focal lymphedema.

  13. Shear-Sensitive Genes in Aortic Valve Endothelium

    PubMed Central

    Fernández Esmerats, Joan; Heath, Jack

    2016-01-01

    Abstract Significance: Currently, calcific aortic valve disease (CAVD) is only treatable through surgical intervention because the specific mechanisms leading to the disease remain unclear. In this review, we explore the forces and structure of the valve, as well as the mechanosensors and downstream signaling in the valve endothelium known to contribute to inflammation and valve dysfunction. Recent Advances: While the valvular structure enables adaptation to dynamic hemodynamic forces, these are impaired during CAVD, resulting in pathological systemic changes. Mechanosensing mechanisms—proteins, sugars, and membrane structures—at the surface of the valve endothelial cell relay mechanical signals to the nucleus. As a result, a large number of mechanosensitive genes are transcribed to alter cellular phenotype and, ultimately, induce inflammation and CAVD. Transforming growth factor-β signaling and Wnt/β-catenin have been widely studied in this context. Importantly, NADPH oxidase and reactive oxygen species/reactive nitrogen species signaling has increasingly been recognized to play a key role in the cellular response to mechanical stimuli. In addition, a number of valvular microRNAs are mechanosensitive and may regulate the progression of CAVD. Critical Issues: While numerous pathways have been described in the pathology of CAVD, no treatment options are available to avoid surgery for advanced stenosis and calcification of the aortic valve. More work must be focused on this issue to lead to successful therapies for the disease. Future Directions: Ultimately, a more complete understanding of the mechanisms within the aortic valve endothelium will lead us to future therapies important for treatment of CAVD without the risks involved with valve replacement or repair. Antioxid. Redox Signal. 25, 401–414. PMID:26651130

  14. The flaws in the detail of an observational study on transcatheter aortic valve implantation versus surgical aortic valve replacement in intermediate-risks patients.

    PubMed

    Barili, Fabio; Freemantle, Nick; Folliguet, Thierry; Muneretto, Claudio; De Bonis, Michele; Czerny, Martin; Obadia, Jean Francois; Al-Attar, Nawwar; Bonaros, Nikolaos; Kluin, Jolanda; Lorusso, Roberto; Punjabi, Prakash; Sadaba, Rafael; Suwalski, Piotr; Benedetto, Umberto; Böning, Andreas; Falk, Volkmar; Sousa-Uva, Miguel; Kappetein, Pieter A; Menicanti, Lorenzo

    2017-06-01

    The PARTNER group recently published a comparison between the latest generation SAPIEN 3 transcatheter aortic valve implantation (TAVI) system (Edwards Lifesciences, Irvine, CA, USA) and surgical aortic valve replacement (SAVR) in intermediate-risk patients, apparently demonstrating superiority of the TAVI and suggesting that TAVI might be the preferred treatment method in this risk class of patients. Nonetheless, assessment of the non-randomized methodology used in this comparison reveals challenges that should be addressed in order to elucidate the validity of the results. The study by Thourani and colleagues showed several major methodological concerns: suboptimal methods in propensity score analysis with evident misspecification of the propensity scores (PS; no adjustment for the most significantly different covariates: left ventricular ejection fraction, moderate-severe mitral regurgitation and associated procedures); use of PS quintiles rather than matching; inference on not-adjusted Kaplan-Meier curves, although the authors correctly claimed for the need of balancing score adjusting for confounding factors in order to have unbiased estimates of the treatment effect; evidence of poor fit; lack of data on valve-related death.These methodological flaws invalidate direct comparison between treatments and cannot support authors' conclusions that TAVI with SAPIEN 3 in intermediate-risk patients is superior to surgery and might be the preferred treatment alternative to surgery. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. New Technologies for Surgery of the Congenital Cardiac Defect

    PubMed Central

    Kalfa, David; Bacha, Emile

    2013-01-01

    The surgical repair of complex congenital heart defects frequently requires additional tissue in various forms, such as patches, conduits, and valves. These devices often require replacement over a patient’s lifetime because of degeneration, calcification, or lack of growth. The main new technologies in congenital cardiac surgery aim at, on the one hand, avoiding such reoperations and, on the other hand, improving long-term outcomes of devices used to repair or replace diseased structural malformations. These technologies are: 1) new patches: CorMatrix® patches made of decellularized porcine small intestinal submucosa extracellular matrix; 2) new devices: the Melody® valve (for percutaneous pulmonary valve implantation) and tissue-engineered valved conduits (either decellularized scaffolds or polymeric scaffolds); and 3) new emerging fields, such as antenatal corrective cardiac surgery or robotically assisted congenital cardiac surgical procedures. These new technologies for structural malformation surgery are still in their infancy but certainly present great promise for the future. But the translation of these emerging technologies to routine health care and public health policy will also largely depend on economic considerations, value judgments, and political factors. PMID:23908869

  16. Percutaneous pulmonary and tricuspid valve implantations: An update

    PubMed Central

    Wagner, Robert; Daehnert, Ingo; Lurz, Philipp

    2015-01-01

    The field of percutaneous valvular interventions is one of the most exciting and rapidly developing within interventional cardiology. Percutaneous procedures focusing on aortic and mitral valve replacement or interventional treatment as well as techniques of percutaneous pulmonary valve implantation have already reached worldwide clinical acceptance and routine interventional procedure status. Although techniques of percutaneous pulmonary valve implantation have been described just a decade ago, two stent-mounted complementary devices were successfully introduced and more than 3000 of these procedures have been performed worldwide. In contrast, percutaneous treatment of tricuspid valve dysfunction is still evolving on a much earlier level and has so far not reached routine interventional procedure status. Taking into account that an “interdisciplinary challenging”, heterogeneous population of patients previously treated by corrective, semi-corrective or palliative surgical procedures is growing inexorably, there is a rapidly increasing need of treatment options besides redo-surgery. Therefore, the review intends to reflect on clinical expansion of percutaneous pulmonary and tricuspid valve procedures, to update on current devices, to discuss indications and patient selection criteria, to report on clinical results and finally to consider future directions. PMID:25914786

  17. Thromboembolism in patients with pericardial valves in the absence of chronic anticoagulation: 12 years' experience.

    PubMed

    García-Bengoechea, J B; González-Juanatey, J R; Rubio, J; Durán, D; Sierra, J

    1991-01-01

    Between January 1977 and January 1989, 465 pericardial bioprostheses were implanted in 424 patients. The mean age of patients was 59.1 years (range 16-81 y.) At the time of surgery, 68% of the patients suffered from chronic atrial fibrillation. Mitral valve replacement was performed in 167 patients, aortic valve replacement in 216, multiple replacement in 40 (36 mitral and aortic, 3 mitral and tricuspid, and 1 mitral, aortic and tricuspid), and 1 pulmonary valve replacement. The different types of pericardial valve used were: Ionescu-Shiley 408, Mitral Medical 23, Bioflo 30, and Hancock 4. Hospital mortality was 10.1% with an attrition rate of 1.8 episodes per 100 patients/year. The 12-year actuarial survival rate was 65.1%. No patient underwent long-term anticoagulant treatment. The first 144 patients undergoing mitral and multiple valve replacements received temporary anticoagulation for the first 8 weeks after surgery. There was no valve thrombosis observed. Altogether 19 thromboembolic events (6 early and 13 late) were clinically documented. One patient died after an embolic event. The linearized rates of thromboembolism were 1.64 episodes per 100 patients/year for mitral and multiple valve replacements and 0.33 episodes per 100 patients/year for aortic valve replacement, with an overall rate of 1.0 episodes per 100 patients/year. Excluding early thromboembolism, the linearized rate was 1.02 episodes per 100 patients/year overall. The actuarial freedom from embolism was 92.4% overall, 88.2% for the mitral and multiple valve replacement group, and 97.6% for the aortic valve replacement group at a maximum follow-up of 12 years.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Tetralogy of Fallot with absent pulmonary valve syndrome; appropriate surgical strategies.

    PubMed

    Shahid, Fatima; Siddiqui, Maria Tariq; Amanullah, Muhammad Muneer

    2015-05-01

    To evaluate patients presenting with Tetralogy of Fallot with absent pulmonary valve syndrome to a tertiary care hospital and their surgical management. The retrospective study was conducted at Congenital Cardiac Services, Aga Khan University Hospital, Karachi, Pakistan, and comprised data of Tetralogy of Fallot patients between April 2007 and June 2012. Data was analysed together with follow-up echocardiography. Variables assessed included demographics, imaging, operative technique, complications, post-operative recovery and follow-up echocardiography. SPSS 17 was used for statistical analysis. Of the 204 patients, 6 (3%) had undergone surgical correction for Tetralogy of Fallot with absent pulmonary valve syndrome. All 6(100%) patients underwent complete repair. Median age for surgery was 8.5 years (range: 0.5-29 years). Of the different surgical strategies used, Contegra and Bioprosthetic valve placement had satisfactory outcome with minimal gradient at Right Ventricular Outflow Tract, good ventricular function and mild valvular regurgitation. One (16.6%) patient with Trans Annular Patch developed post-operative Right Ventricle Outflow Tract gradient of 80mmHg with moderate pulmonary regurgitation. One (16.6%) patient with monocusp valve developed free pulmonary regurgitation at 6 months. The other 4(66.6%) patients are currently free from any complications or re-intervention. Early surgery is preferred in symptomatic patients. The repair depends upon achieving integrity of pulmonary circulation which is best achieved by using right ventricle to pulmonary artery conduit or inserting a pulmonary valve.

  19. Aortic valve replacement in a Jehovah’s Witness: a case of multi-disciplinary clinical management for bloodless surgery

    PubMed Central

    Park, John Jungpa; Lang, Christopher C; Manson, Lynn; Brackenbury, Edward T

    2012-01-01

    An 81-year-old female Jehovah’s Witness (JW) patient with severe aortic stenosis required aortic valve replacement (AVR). However, the patient’s religious beliefs precluded the use of primary blood components. Since the definitive treatment of AVR required bloodless open heart surgery, careful peri-operative plans were set forth by a multi-disciplinary team involving the cardiothoracic surgeon, haematologist and anaesthetist. The patient went on to successfully recover postoperatively. This case highlights: 1) The importance of carefully navigating through the most recent clinical and ethical protocol involved in the surgical management of JW’s. 2) The importance of preparing individually tailored pre, intra and postoperative plans that are delivered through a multi-disciplinary clinical team to ensure the best and safest possible outcomes. PMID:22665474

  20. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    PubMed

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  1. Hemodynamic deterioration after aortic valve replacement in a patient with mixed systemic amyloidosis.

    PubMed

    Seki, Tatsuya; Hattori, Atsuo; Yoshida, Toshihito

    2017-08-01

    We report a case of hemodynamic deterioration after aortic valve replacement in a patient with mixed systemic amyloidosis. A 77-year-old male with severe aortic valve stenosis and 19 years hemodialysis underwent aortic valve replacement. Postoperatively, the patient died of hemodynamic deterioration. Autopsy findings showed massive, whole-body edema and mixed systemic amyloidosis (dialysis-related and AA amyloidosis). Clinical and autopsy findings implied that hemodynamic deterioration was caused by increased vascular permeability. The amyloid deposit to the vessel causes inflammatory changes and increases vascular permeability. Mixed systemic amyloidosis occurs very rarely and could increases vascular permeability even more than each single type of amyloidosis. Systemic amyloidosis may be a risk factor for hemodynamic deterioration after cardiac surgery. Patients with longtime hemodialysis and a history associated with dialysis-related amyloidosis would have at least single systemic amyloidosis, which should be considered a contraindication to cardiac surgery with cardiopulmonary bypass.

  2. Aortic valve type and calcification as assessed by transthoracic and transoesophageal echocardiography.

    PubMed

    Yousry, Mohamed; Rickenlund, Anette; Petrini, Johan; Jenner, Jonas; Liska, Jan; Eriksson, Per; Franco-Cereceda, Anders; Eriksson, Maria J; Caidahl, Kenneth

    2015-07-01

    Aortic valve calcification (AVC) may predict poor outcome. Bicuspid aortic valve (BAV) leads to several haemodynamic changes accelerating the progress of aortic valve (AV) disease. To compare the diagnostic accuracy of transoesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in the assessment of aortic valve phenotype and degree of AVC, with intra-operative evaluation as a reference. We examined 169 patients (median age 65 years, 51 women) without significant coronary artery disease undergoing AV and/or aortic root surgery. TTE was performed within a week prior to surgery and TEE at the time of surgery. Compared with surgical AVC assessment, visual evaluation using a 5-grade scoring system and real-time images showed a higher correlation (TTE r = 0·83 and TEE r = 0·82) than visual (TTE r = 0·64 and TEE 0·63) or grey scale mean (GSMn) (TTE r = 0·63 and TEE r = 0·52) assessment of end-diastolic still frames. AVC assessment using real-time images showed high intraclass correlation coefficients (TTE 0·94 and TEE 0·93). With regard to BAV, TEE was superior to TTE with a higher interobserver agreement, sensitivity and specificity (0·86, 92% and 94% versus 0·57, 77% and 82%, respectively). Semi-quantitative AVC assessment of real-time cine loops from both TEE and TTE correlated well with intra-operative evaluation of AVC. Applying a predefined scoring system for AVC evaluation assures a high interobserver correlation. TEE was superior to TTE for evaluation of valve phenotype and should be considered when a diagnosis of BAV is clinically important. © 2014 The Authors. Clinical Physiology and Functional Imaging published by John Wiley & Sons Ltd on behalf of Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  3. Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.

    PubMed

    Braunberger, E; Deloche, A; Berrebi, A; Abdallah, F; Celestin, J A; Meimoun, P; Chatellier, G; Chauvaud, S; Fabiani, J N; Carpentier, A

    2001-09-18

    Mitral valve repair is considered the gold standard in surgery of degenerative mitral valve insufficiency (MVI), but the long-term results (>20 years) are unknown. We reviewed the first 162 consecutive patients who underwent mitral valve repair between 1970 and 1984 for MVI due to nonrheumatic disease. The cause of MVI was degenerative in 146 patients (90%) and bacterial endocarditis in 16 patients (10%). MVI was isolated or, in 18 cases, associated with tricuspid insufficiency. The mean age of the 162 patients (104 men and 58 women) was 56+/-10 years (age range 22 to 77 years). New York Heart Association functional class was I, II, III, and IV in 2%, 39%, 52%, and 7% of patients, respectively. The mean cardiothoracic ratio was 0.58+/-0.07 (0.4 to 0.8), and 72 (45%) patients had atrial fibrillation. Valve analysis showed that the main mechanism of MVI was type II Carpentier's functional classification in 152 patients. The leaflet prolapse involved the posterior leaflet in 93 patients, the anterior leaflet in 28 patients, and both leaflets in 31 patients. Surgical technique included a Carpentier's ring annuloplasty in all cases, a valve resection in 126 patients, and shortening or transposition of chordae in 49 patients. During the first postoperative month, there were 3 deaths (1.9%) and 3 reoperations (2 valve replacements and 1 repeat repair [1.9%]). Six patients were lost to follow-up. The remaining 151 patients with mitral valve repair were followed during a median of 17 years (range 1 to 29 years; 2273 patient-years). The 20-year Kaplan-Meier survival rate was 48% (95% CI 40% to 57%), which is similar to the survival rate for a normal population with the same age structure. The 20-year rates were 19.3% (95% CI 11% to 27%) for cardiac death and 26% (95% CI 17% to 35%) for cardiac morbidity/mortality (including death from a cardiac cause, stroke, and reoperation). During the 20 years of follow-up, 7 patients were underwent surgery at 3, 7, 7, 8, 8, 10, or 12

  4. Profiling illness perceptions to identify patients at-risk for decline in health status after heart valve replacement.

    PubMed

    Kohlmann, Sebastian; Rimington, Helen; Weinman, John

    2012-06-01

    Identification of risk factors for decline in health status by profiling illness perceptions before and one year after heart valve replacement surgery. Prospective data from N=225 consecutively admitted first time valve replacement patients was assessed before and one year after surgery. Patients were asked about their illness perceptions (Illness Perception Questionnaire-Revised) and mood state (Hospital Anxiety and Depression Scale). Health status was defined by quality of life (Short-Form 36) and New York Heart Association (NYHA) class. Cluster analyses were conducted to identify illness perception profiles over time. Predictors of health status after surgery were analyzed with multivariate methods. Patients were grouped according to the stability and nature (positive, negative) of their illness perception profile over one year. One year after surgery patients holding a negative illness perception profile showed a lower physical quality of life and were diagnosed in a higher New York Heart Association class than patients changing to positive and patients with stable positive illness perceptions (P<.001). Over and above biological determinants, post-surgery physical quality of life and NYHA class were both predicted by pre-surgery illness perception profiles (P<.05). Patients going for heart valve replacement surgery can be easily categorized into illness perception profiles that predict health status one year after surgery. These patients could benefit from early screening as negative illness perceptions are modifiable risk factors. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Clinical outcomes of trabeculectomy vs. Ahmed glaucoma valve implantation in patients with penetrating keratoplasty : (Trabeculectomy vs. Ahmed galucoma valve in patients with penetrating keratoplasty).

    PubMed

    Akdemir, Mehmet Orcun; Acar, Banu Torun; Kokturk, Furuzan; Acar, Suphi

    2016-08-01

    The aim of this study was to compare the visual outcomes, intraocular pressure (IOP), and endothelial cell loss caused by trabeculectomy (TRAB) and Ahmed glaucoma valve (AGV) implantation in patients who had previously undergone penetrating keratoplasty (PKP). The data from all patients who underwent surgical treatment of glaucoma after PKP were reviewed at the Cornea Department of Haydarpasa Numune Education and Research Hospital. Eighteen patients who had undergone surgical treatment of glaucoma after PKP were included in this retrospective study. Time between PKP and glaucoma surgeries, visual acuity results, IOP results, endothelial cell counts (ECC) before the surgery, at 1st, 6th, and 12th month of surgery were recorded. Differences between two groups were evaluated. Mean loss of ECC was 315 cells/mm(2) in the AGV group and 197 cells/mm(2) in TRAB group at 12th month of glaucoma surgery. The difference between endothelial cell loss at 12th month of surgery was statistically significant and higher in AGV group (p < 0.001). The decrease in IOP was 64.2 % in AGV group and 46.9 % in TRAB group at 12th month of surgery. Both differences were statistically significant between 2 groups (p = 0.001, 0.001). TRAB successfully decreased both the IOP and endothelial cell loss in patients with post-PKP glaucoma. Ahmed glaucoma valve had a significantly better IOP lowering but higher endothelial cell loss effect.

  6. Transcatheter aortic valve-in-valve implantation of a CoreValve in a JenaValve prosthesis: a case report.

    PubMed

    Lotfi, Shahram; Becker, Michael; Moza, Ajay; Autschbach, Rüdiger; Marx, Nikolaus; Schröder, Jörg

    2017-09-10

    Transcatheter aortic valve implantation has become an accepted treatment modality for inoperable or high-risk surgical patients with symptomatic severe aortic stenosis. We report the case of a 70-year-old white man who was treated for severe symptomatic aortic regurgitation using transcatheter aortic valve implantation from the apical approach. Because of recurrent cardiac decompensation 4 weeks after implantation he underwent the implantation of a left ventricular assist device system. A year later echocardiography showed a severe transvalvular central insufficiency. Our heart team decided to choose a valve-in-valve approach while reducing the flow rate of left ventricular assist device to minimum and pacing with a frequency of 140 beats/minute. There was an excellent result and our patient is doing well with no relevant insufficiency of the aortic valve at 12-month follow-up. This is the first report about a successful treatment of a stenotic JenaValve using a CoreValve Evolut R; the use of a CoreValve Evolut R prosthesis may be an optimal option for valve-in-valve procedures.

  7. Factors Influencing Mortality after Bioprosthetic Valve Replacement; A Midterm Outcome

    PubMed Central

    Javadzadegan, Hassan; Javadzadegan, Amir; Mehdizadeh Baghbani, Jafar

    2013-01-01

    Introduction: Although valve repair is applied routinely nowadays, particularly for mitral regurgitation (MR) or tricuspid regurgitation (TR), valve replacement using prosthetic valves is also common especially in adults. Unfortunately the valve with ideal hemodynamic performance and long-term durability without increasing the risk of bleeding due to long-term anticoagulant therapy has not been introduced. Therefore, patients and physicians must choose either bioprosthetic or mechanical valves. Currently, there is an increasing clinical trend of using bioprosthetic valves instead of mechanical valves even in young patients apparently because of their advantages. Methods: Seventy patients undergone valvular replacement using bioprosthetic valves were evaluated by ECG and Echocardiography to assess the rhythm and ejection fracture. Mean follow-up time was 33 months (min 9, max 92). Results: Mortality rate was 25.9% (n=18) within 8 years of follow-up. Statistical analysis showed a significant relation between atrial fibrillation rhythm and mortality (P=0.02). Morbidities occurred in 30 patients (42.8%). Significant statistical relation was found between the morbidities and age over 65 years old (P=0.005). In follow-up period, 4 cases (5.7%) underwent re-operation due to global valve dysfunction. Conclusion: Our study shows that using biprosthetic valve could reduce the risk of morbidity occurrence in patient who needs valve replacement. However, if medical treatments fail, patients should be referred for surgery. This would reduce the risk of mortality because of lower incident of complications such as atrial fibrillation and morbidities due to younger patients' population. PMID:24404348

  8. Right heart chamber geometry and tricuspid annulus morphology in patients undergoing mitral valve repair with and without tricuspid valve annuloplasty.

    PubMed

    Tamborini, Gloria; Fusini, Laura; Muratori, Manuela; Gripari, Paola; Ghulam Ali, Sarah; Fiorentini, Cesare; Pepi, Mauro

    2016-06-01

    According to current recommendations, patients could benefit from tricuspid valve (TV) annuloplasty at the time mitral valve (MV) surgery if tricuspid regurgitation is severe or if tricuspid annulus (TA) dilatation is present. Therefore, an accurate pre-operative echocardiographic study is mandatory for left but also for right cardiac structures. Aims of this study are to assess right atrial (RA), right ventricular (RV) and TA geometry and function in patients undergoing MV repair without or with TV annuloplasty. We studied 103 patients undergoing MV surgery without (G1: 54 cases) or with (G2: 49 cases) concomitant TV annuloplasty and 40 healthy subjects (NL) as controls. RA, RV and TA were evaluated by three-dimensional (3D) transthoracic echocardiography. Comparing the pathological to the NL group, TA parameters and 3D right chamber volumes were significantly larger. RA and RV ejection fraction and TA% reduction were lower in pathological versus NL, and in G2 versus G1. In pathological patients, TA area positively correlated to systolic pulmonary pressure and negatively with RV and RA ejection fraction. Patients undergoing MV surgery and TV annuloplasty had an increased TA dimensions and a more advanced remodeling of right heart chambers probably reflecting an advanced stage of the disease.

  9. Spontaneous bleeding from liver after open heart surgery.

    PubMed

    Mir, Najeeb H; Shah, Mian T; Obeid, Mahmoud Ali; Gallo, Ricardo; Aliter, Hashem

    2013-01-01

    Intra-abdominal hemorrhage after open heart surgery is very uncommon in routine clinical practice. There are case reports of having bleeding from spleen or liver after starting low molecular weight heparin (LMWH) postoperatively. Our patient is a 58-year-old man with mitral valve regurgitation, who underwent mitral valve repair and developed intra-abdominal hemorrhage 8h after open heart surgery. The exploratory laparotomy revealed the source of bleeding from ruptured sub-capsular liver hematoma and oozing from raw areas of the liver surface. Liver packing was done to control the bleeding. The gastrointestinal complications after open heart surgery are rare and spontaneous bleeding from spleen has been reported. This is the first case from our hospital to have intra-abdominal hemorrhage after open heart surgery. Spontaneous bleeding from liver is a possible complication after open heart surgery. We submit the case for the academic interest and to discuss the possible cause of hemorrhage. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    PubMed

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  11. Azygos vein aneurysm resection concomitant with heart valve repair via right thoracotomy.

    PubMed

    Suzuki, Yota; Kaji, Masahiro; Hirose, Shigemichi; Ohtsubo, Satoshi

    2016-12-01

    Azygos vein aneurysm is very rare and is usually found incidentally because of its clinical silence. We report a case of recurrent pleural effusion caused by an azygos vein aneurysm in a patient with moderate mitral valve regurgitation (MR) and tricuspid valve regurgitation (TR). Since valve disease is considered a significant precipitating factor for both dyspnoea and pleural effusion, we decided to study the aetiologies of these conditions concomitantly. Azygos vein aneurysm resection in combination with tricuspid and mitral valve repair using cardiopulmonary bypass was performed successfully through a right anterior thoracotomy. The postoperative course was uneventful, and the patient reported improved exercise capacity. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Prosthetic Tricuspid Valve Thrombosis: Three Case Reports and Literature Review

    PubMed Central

    Yaminisharif, Ahmad; Alemzadeh-Ansari, Mohammad Javad; Ahmadi, Seyed Hossein

    2012-01-01

    A common complication of prosthetic heart valves is thrombosis. Although the incidence of prosthetic valve thrombosis (PVT) in the tricuspid position is high, there are not enough data on the management of it, in contrast to left-sided PVT. Here, we describe three cases of tricuspid PVT with three different management approaches: thrombolytic therapy; close observation with oral anticoagulants; and surgery. The first case was a woman who suffered from recurrent PVT, for which we successfully used Tenecteplase for second and third episodes. We employed Tenecteplase in this case for the first time in the therapy of tricuspid PVT. The second case had fixed leaflets in open position while being symptomless. At six months' follow-up, with the patient having taken oral anticoagulants, the motion of the leaflets was restricted and she was symptomfree. The last case was a woman who had a large thrombus in the right atrium immediately after mitral and tricuspid valvular replacement. The patient underwent re-replacement surgery and a new biological valve was implanted in the tricuspid position. Also, we review the literature on the pathology, signs and symptoms, diagnosis, and management of tricuspid PVT. PMID:23323074

  13. The importance of echocardiography in transcatheter aortic valve implantation.

    PubMed

    Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin

    2014-01-01

    Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.

  14. Repair or Replacement for Isolated Tricuspid Valve Pathology? Insights from a Surgical Analysis on Long-Term Survival

    PubMed Central

    Farag, Mina; Arif, Rawa; Sabashnikov, Anton; Zeriouh, Mohamed; Popov, Aron-Frederik; Ruhparwar, Arjang; Schmack, Bastian; Dohmen, Pascal M.; Szabó, Gábor; Karck, Matthias; Weymann, Alexander

    2017-01-01

    Background Long-term follow-up data concerning isolated tricuspid valve pathology after replacement or reconstruction is limited. Current American Heart Association guidelines equally recommend repair and replacement when surgical intervention is indicated. Our aim was to investigate and compare operative mortality and long-term survival in patients undergoing isolated tricuspid valve repair surgery versus replacement. Material/Methods Between 1995 and 2011, 109 consecutive patients underwent surgical correction of tricuspid valve pathology at our institution for varying structural pathologies. A total of 41 (37.6%) patients underwent tricuspid annuloplasty/repair (TAP) with or without ring implantation, while 68 (62.3%) patients received tricuspid valve replacement (TVR) of whom 36 (53%) were mechanical and 32 (47%) were biological prostheses. Results Early survival at 30 days after surgery was 97.6% in the TAP group and 91.1% in the TVR group. After 6 months, 89.1% in the TAP group and 87.8% in the TVR group were alive. In terms of long-term survival, there was no further mortality observed after one year post surgery in both groups (Log Rank p=0.919, Breslow p=0.834, Tarone-Ware p=0.880) in the Kaplan-Meier Survival analysis. The 1-, 5-, and 8-year survival rates were 85.8% for TAP and 87.8% for TVR group. Conclusions Surgical repair of the tricuspid valve does not show survival benefit when compared to replacement. Hence valve replacement should be considered generously in patients with reasonable suspicion that regurgitation after repair will reoccur. PMID:28236633

  15. Does the disparity in baseline characteristics of patients undergoing transcatheter aortic valve replacement with 23 mm vs. 26 mm valves impact clinical outcome?

    PubMed

    Escárcega, Ricardo O; Magalhaes, Marco A; Baker, Nevin C; Lipinski, Michael J; Minha, Sa'ar; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-01-01

    We sought to identify if baseline characteristic differences in patients who receive a 23 mm vs. 26 mm valve impact clinical outcomes. Transcatheter aortic valve replacement (TAVR) is currently an approved therapy for patients with severe aortic stenosis who are considered inoperable or are at high risk. We retrospectively examined baseline characteristics and outcomes of patients receiving a 23 mm (n = 132) vs. 26 mm valve (n = 81) via the transfemoral approach. Gender (P < 0.01), previous coronary artery bypass surgery (P < 0.01), history of atrial fibrillation (P = 0.04), and mean Society of Thoracic Surgeons (STS) score (P < 0.01) were significantly different between groups. There were no significant differences in the rates of minor/major vascular complications (2.2 vs. 3.7%, P = 0.68 and 13.0 vs. 12.3%, P = 0.89, respectively). Bleeding complications were also comparable (major bleed 2.3 vs. 1%, P >0.99, minor bleed 19.0 vs. 22.0%, P = 0.67 and life threatening bleed 7.0 vs. 5.0%, P = 0.77). In-hospital death (6.0 vs. 5.0%, P >0.99), 30-day all-cause death (7.6 vs. 6.2%, P = 0.69), and all-cause death at 1 year (17.4 vs. 25.9%, P = 0.13) were also similar between groups. Gender, valve size, previous coronary bypass surgery and atrial fibrillation were not independently associated with mortality; however, on multivariate analysis STS score was (HR 1.11; 95% CI 1.02-1.19; P = 0.01). Patients undergoing TAVR with 23 and 26 mm valves have similar clinical outcomes despite significant differences in baseline characteristics. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  16. Stroke after Aortic Valve Surgery: Results from a Prospective Cohort

    PubMed Central

    Messé, Steven R.; Acker, Michael A.; Kasner, Scott E.; Fanning, Molly; Giovannetti, Tania; Ratcliffe, Sarah J.; Bilello, Michel; Szeto, Wilson Y.; Bavaria, Joseph E.; Hargrove, W. Clark; Mohler, Emile R.; Floyd, Thomas F.

    2014-01-01

    Background The incidence and impact of clinical stroke and silent radiographic cerebral infarction complicating open surgical aortic valve replacement (AVR) are poorly characterized. Methods and Results We performed a prospective cohort study of subjects ≥ 65 years of age undergoing AVR for calcific aortic stenosis. Subjects were evaluated by neurologists pre-operatively and post-operatively, and underwent post-operative magnetic resonance imaging (MRI). Over a 4 year period, 196 subjects were enrolled at 2 sites. Mean age = 75.8 ± 6.2 years, 36% female, 6% non-white. Clinical strokes were detected in 17%, Transient Ischemic Attack in 2%, and in-hospital mortality was 5%. The frequency of stroke in the Society for Thoracic Surgery (STS) database in this cohort was 7%. Most strokes were mild; the median National Institutes of Health Stroke Scale (NIHSS) was 3 (interquartile range 1 – 9). Clinical stroke was associated with increased length of stay, median 12 vs 10 days, p = 0.02. Moderate or severe stroke (NIHSS ≥10) occurred in 8 (4%) and was strongly associated with in-hospital mortality, 38% vs 4%, p = 0.005. Of the 109 stroke-free subjects with post-operative MRI, silent infarct was identified in 59 (54%). Silent infarct was not associated with in-hospital mortality or increased length of stay. Conclusions Clinical stroke after AVR was more common than previously reported, more than double for this same cohort in the STS database, and silent cerebral infarctions were detected in over half of patients undergoing AVR. Clinical stroke complicating AVR is associated with increased length of stay and mortality. PMID:24690611

  17. CARDIAC SURGERY FOR VALVULAR HEART DISEASE AT A REFERRAL HOSPITAL IN ETHIOPIA: A REVIEW OF CASES OPERATED IN THE LAST 30 YEARS.

    PubMed

    Guteta, Senbeta; Yadeta, Dejuma; Azazh, Aklilu; Mekonnen, Dufera

    2016-04-01

    Valvular heart disease has been a significant cause of heart disease worldwide. In Ethiopia, it particularly affects young individuals and constitutes the major cause of cardiovascular disease. Factors associated with choice of treatment for advanced valvular heart disease are variable. The objective of this study is to review surgery done for Ethiopian patients with valvular heart disease. We analyzed data on patients who had valve surgery and follow-up at the Tikur Anbessa Specialized Hospital cardiology unit. We collected data on sociodemographic characteristics, the pre-operative status of effected valves and co-morbidities, and assessed their associations with patient management options. A total of 157 valve surgeries were done from 1983 to 2013. Mean age at time of surgery was 26.7 years and females constituted 66% of the cases. Patients with rheumatic heart disease were younger, more likely to be female and have atrial fibrillation, but less likely to have impaired left ventricular systolic function when compared to patients with non-rheumatic heart disease. More than 75% of the surgical procedures done were mechanical valve replacement. Mechanical valves, compared with bioprosthetic valves, were more likely to be used in patients with rheumatic heart disease. The median age of those receiving mechanical valves, 24 (IQR 22-28) years, was lower than those receiving bioprosthetic valves, 31.5 (IQR 29.9-37.9) years. Mechanical valve replacement was significantly higher in those under the age of 20 years (Adjusted Odds Ratio 41.0, 95% CI: 3.0-557.2) and in those between 20 and 29 years of age (Adjusted Odds Ratio 14.3, 95% CI: 2.3-88.6). Valve surgery for valvular heart diseases has been more common performed for young and female patients. A great majority of the replacements done have been with mechanical valves. As many of the patients have been younger and female, the choice of valve surgery and the need for anticoagulation impacts subsequent management of

  18. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  19. The utility of trans-catheter aortic valve replacement after commercialization: does the European experience provide a glimpse into the future use of this technology in the United States?

    PubMed

    Linke, Axel; Walther, Thomas; Schuler, Gerhard

    2010-03-01

    Treatment of aortic stenosis remains challenging in older individuals, as their perioperative mortality for open heart surgery is increased due to comorbidities. Transcatheter aortic valve implantation using the CoreValve ReValving System (Medtronic, Minneapolis, USA) and the Edwards SAPIEN transcatheter heart valve (THV; Edwards Lifescience, Irvine, California, USA) represents an alternative to conventional valve replacement in elderly patients that have a high risk for conventional surgery. This article summarizes the evidence-base from recent clinical trials. The early results of these landmark studies suggest that transcatheter aortic valve implantation with either one of the prosthesis is feasible, safe, improves hemodynamics and, therefore, might be an alternative to conventional aortic valve replacement in very high-risk patients. However, all of the available transcatheter heart valves have certain disadvantages, limiting their use in daily clinical practice. The process of decision making, which valve to use and which access route to choose is illustrated in this article through clinical case scenarios. Additionally, the lessons learned thus far from the European perspective and the potential impact on the future use in the US are discussed. Despite of the progress in this field, we are still lacking an optimal transcatheter heart valve. Once it is available, we can take the plunge to compare transcatheter valve implantation with convention surgery in severe aortic stenosis!

  20. Acute failure of a St. Jude's prosthetic aortic valve: large pannus formation masked by a small thrombus.

    PubMed

    Hurwitz, Seth Eric; Waxman, Daniel; Hecht, Susan

    2009-09-01

    Pannus formation and valve thrombus can cause prosthetic valve failure. The authors report the case of a 50-year-old woman who presented to the emergency room with decompensated heart failure secondary to mechanical valve dysfunction. On two-dimensional and transesophageal echocardiography, the patient had severe aortic stenosis and regurgitation. A thrombus seen on the valve was felt to be the etiology of her prosthetic valve failure. She underwent emergent cardiac surgery for aortic valve replacement. Pathology revealed that although a small thrombus was present, extensive pannus was the underlying mechanism of valve dysfunction. Differentiation between pannus and thrombus may have important clinical implications, but this case illustrates that distinguishing between these entities by echocardiographic and clinical criteria may not be possible.

  1. Aortic valve repair using a differentiated surgical strategy.

    PubMed

    Langer, Frank; Aicher, Diana; Kissinger, Anke; Wendler, Olaf; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim

    2004-09-14

    Reconstruction of the aortic valve for aortic regurgitation (AR) remains challenging, in part because of not only cusp or root pathology but also a combination of both can be responsible for this valve dysfunction. We have systematically tailored the repair to the individual pathology of cusps and root. Between October 1995 and August 2003, aortic valve repair was performed in 282 of 493 patients undergoing surgery for AR and concomitant disease. Root dilatation was corrected by subcommissural plication (n=59), supracommissural aortic replacement (n=27), root remodeling (n=175), or valve reimplantation within a graft (n=24). Cusp prolapse was corrected by plication of the free margin (n=157) or triangular resection (n =36), cusp defects were closed with a pericardial patch (n=16). Additional procedures were arch replacement (n=114), coronary artery bypass graft (n=60) or mitral repair (n=24). All patients were followed-up (follow-up 99.6% complete), and cumulative follow-up was 8425 patient-months (mean, 33+/-27 months).Results- Eleven patients died in hospital (3.9%). Nine patients underwent reoperation for recurrent AR (3.3%). Actuarial freedom from AR grade > or =II at 5 years was 81% for isolated valve repair, 84% for isolated root replacement, and 94% for combination of both; actuarial freedom from reoperation at 5 years was 93%, 95%, and 98%, respectively. No thromboembolic events occurred, and there was 1 episode of endocarditis 4.5 years postoperatively. Aortic valve repair is feasible even for complex mechanisms of AR with a systematic and individually tailored approach. Operative mortality is low and mid-term durability is encouraging. The incidence of valve-related morbidity is low compared with valve replacement.

  2. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    PubMed

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p < 0.001). Thoracic aortic aneurysms were significantly more likely to be diagnosed in late follow-up in patients with Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p < 0.001). Patients with Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p < 0.001). The much higher long-term rates of aortic complications after AVR observed in patients with Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities

  3. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    PubMed

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  4. Patient-specific indirectly 3D printed mitral valves for pre-operative surgical modelling

    NASA Astrophysics Data System (ADS)

    Ginty, Olivia; Moore, John; Xia, Wenyao; Bainbridge, Dan; Peters, Terry

    2017-03-01

    Significant mitral valve regurgitation affects over 2% of the population. Over the past few decades, mitral valve (MV) repair has become the preferred treatment option, producing better patient outcomes than MV replacement, but requiring more expertise. Recently, 3D printing has been used to assist surgeons in planning optimal treatments for complex surgery, thus increasing the experience of surgeons and the success of MV repairs. However, while commercially available 3D printers are capable of printing soft, tissue-like material, they cannot replicate the demanding combination of echogenicity, physical flexibility and strength of the mitral valve. In this work, we propose the use of trans-esophageal echocardiography (TEE) 3D image data and inexpensive 3D printing technology to create patient specific mitral valve models. Patient specific 3D TEE images were segmented and used to generate a profile of the mitral valve leaflets. This profile was 3D printed and integrated into a mold to generate a silicone valve model that was placed in a dynamic heart phantom. Our primary goal is to use silicone models to assess different repair options prior to surgery, in the hope of optimizing patient outcomes. As a corollary, a database of patient specific models can then be used as a trainer for new surgeons, using a beating heart simulator to assess success. The current work reports preliminary results, quantifying basic morphological properties. The models were assessed using 3D TEE images, as well as 2D and 3D Doppler images for comparison to the original patient TEE data.

  5. Does concomitant tricuspid annuloplasty increase perioperative mortality and morbidity when correcting left-sided valve disease?

    PubMed

    Zhu, Tie-Yuan; Wang, Jian-Gang; Meng, Xu

    2015-01-01

    A best evidence topic in adult valvular surgery was written according to a structured protocol. The question addressed was 'Does concomitant tricuspid annuloplasty increase the perioperative mortality and morbidity when correcting left-sided valve disease?' A total of 561 papers were found using the reported search, of which 12 presented the best evidence to answer the clinical question. The authors, country, journal, date of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Among these 12 papers, there were nine retrospective studies, two cohort studies and one randomized controlled trial (RCT). Overall, additional tricuspid valve (TV) repair takes more time during operations, particularly with a ring annuloplasty method. The mean aortic cross-clamping times were 57-83 min without associated tricuspid repair and 62-100 min with, and cardiopulmonary bypass times without and with repair were 82-124 and 90-174 min, respectively. A study of 624 patients who had undergone isolated mitral valve (MV) surgery and MV surgery plus TV repair showed more female and atrial fibrillation patients in the tricuspid valve plasty (TVP) group, but no increase in the 30-day mortality was found. One RCT, presenting similar patient baseline characteristics, also found no difference in the hospital mortality rates between the TVP group and the non-TVP group. Another 10 studies also demonstrated no statistically significant differences in perioperative mortality. In a cohort study of 311 patients undergoing MV repair with or without tricuspid annuloplasty, postoperative complications, such as bleeding, stroke, pacemaker, haemofiltration and myocardial infarction, all showed no statistically significant differences in the two groups. One study retrospectively analysed a large number of patients undergoing either isolated left-sided valve surgery or a concomitant TV repair, and there were no statistically significant differences

  6. Capnocytophaga canimorsus: a rare case of conservatively treated prosthetic valve endocarditis.

    PubMed

    Jalava-Karvinen, Päivi; Grönroos, Juha O; Tuunanen, Helena; Kemppainen, Jukka; Oksi, Jarmo; Hohenthal, Ulla

    2018-05-01

    We describe a rare case of prosthetic valve endocarditis caused by the canine bacterium Capnocytophaga canimorsus in a male aged 73 years. The diagnosis of infective endocarditis was unequivocal, as it blood cultures were positive for C. canimorsus and vegetations were detected on transesophageal echocardiography; the modified Duke criteria were fulfilled. PET-CT showed intense 18 F-FDG uptake of the prosthetic valve area. The patient was treated with antibiotics alone (no surgery), and is now on life-long suppressive antibiotic therapy. To our knowledge, this is the third reported case of prosthetic valve endocarditis caused by C. canimorsus and the first one to have been treated conservatively. © 2018 APMIS. Published by John Wiley & Sons Ltd.

  7. Left ventricular mass regression after aortic valve replacement with the new Mitroflow 12A pericardial bioprosthesis.

    PubMed

    García-Bengochea, José; Sierra, Juan; González-Juanatey, José R; Rubio, José; Vega, Marino; Fernández, Angel L; Sánchez, Daniel

    2006-05-01

    The study aim was to evaluate the durability of the new Mitroflow 12A pericardial bioprosthesis and to assess ventricular mass regression after aortic valve replacement (AVR) in patients with small valves. A total of 326 Mitroflow 12A pericardial bioprostheses was implanted without any other associated valve procedure. The mean patient age was 73.5 +/- 6.1 years; 252 patients (78.0%) were in NYHA class III/IV. Small valves (19 and 21 mm) were implanted in 212 patients (65.6%). The total follow up period was 837.1 patient-years (pt-yr). A subset of 61 patients with preoperative stenosis was selected and submitted to conventional echo-Doppler assessment at a mean period of 11.1 months after surgery. Hospital mortality was 8.6%. At eight years of follow up, survival was 57.1%. Freedom from structural valve deterioration (SVD) was 86.5% per pt-yr. Mean gradients were significantly reduced postoperatively for each valve size (to 18 +/- 8 mmHg for 19-mm valves and 12 +/- 4 mmHg for 25-mm valves). The effective orifice area (EOA) was also increased significantly for all valve sizes (to 1.1 +/- 0.1 cm2 for 19-mm valves and 1.8 +/- 0.2 cm2 for 25-mm valves). The left ventricular mass index (LVMI) decreased significantly, from 177 +/- 29 to 136 +/- 22 g/m2 for the 19-mm valve, and from 200 +/- 42 to 132 +/- 22 g/m2 for the 25-mm valve. The EOA index (EOAI) showed mismatch for the 19- and 21-mm valves (0.74 and 0.82 cm2/m2, respectively). The diagrammatic calculation between LVMI and relative wall thickness after surgery showed that 29.7% of patients achieved a normal pattern of remodeling (including 19- and 21-mm valves), despite various degrees of mismatch. The new Mitroflow 12A pericardial bioprosthesis showed an absence of mechanical failure after an eight-year follow up, with a satisfactory rate of SVD. Significant reductions in LVMI and improved ventricular geometry were observed, despite the small valve sizes implanted.

  8. Does Parsonnet scoring model predict mortality following adult cardiac surgery in India?

    PubMed

    Srilata, Moningi; Padhy, Narmada; Padmaja, Durga; Gopinath, Ramachandran

    2015-01-01

    To validate the Parsonnet scoring model to predict mortality following adult cardiac surgery in Indian scenario. A total of 889 consecutive patients undergoing adult cardiac surgery between January 2010 and April 2011 were included in the study. The Parsonnet score was determined for each patient and its predictive ability for in-hospital mortality was evaluated. The validation of Parsonnet score was performed for the total data and separately for the sub-groups coronary artery bypass grafting (CABG), valve surgery and combined procedures (CABG with valve surgery). The model calibration was performed using Hosmer-Lemeshow goodness of fit test and receiver operating characteristics (ROC) analysis for discrimination. Independent predictors of mortality were assessed from the variables used in the Parsonnet score by multivariate regression analysis. The overall mortality was 6.3% (56 patients), 7.1% (34 patients) for CABG, 4.3% (16 patients) for valve surgery and 16.2% (6 patients) for combined procedures. The Hosmer-Lemeshow statistic was <0.05 for the total data and also within the sub-groups suggesting that the predicted outcome using Parsonnet score did not match the observed outcome. The area under the ROC curve for the total data was 0.699 (95% confidence interval 0.62-0.77) and when tested separately, it was 0.73 (0.64-0.81) for CABG, 0.79 (0.63-0.92) for valve surgery (good discriminatory ability) and only 0.55 (0.26-0.83) for combined procedures. The independent predictors of mortality determined for the total data were low ejection fraction (odds ratio [OR] - 1.7), preoperative intra-aortic balloon pump (OR - 10.7), combined procedures (OR - 5.1), dialysis dependency (OR - 23.4), and re-operation (OR - 9.4). The Parsonnet score yielded a good predictive value for valve surgeries, moderate predictive value for the total data and for CABG and poor predictive value for combined procedures.

  9. Synergistic Utility of Brain Natriuretic Peptide and Left Ventricular Global Longitudinal Strain in Asymptomatic Patients With Significant Primary Mitral Regurgitation and Preserved Systolic Function Undergoing Mitral Valve Surgery.

    PubMed

    Alashi, Alaa; Mentias, Amgad; Patel, Krishna; Gillinov, A Marc; Sabik, Joseph F; Popović, Zoran B; Mihaljevic, Tomislav; Suri, Rakesh M; Rodriguez, L Leonardo; Svensson, Lars G; Griffin, Brian P; Desai, Milind Y

    2016-07-01

    In asymptomatic patients with ≥3+ mitral regurgitation and preserved left ventricular (LV) ejection fraction who underwent mitral valve surgery, we sought to discover whether baseline LV global longitudinal strain (LV-GLS) and brain natriuretic peptide provided incremental prognostic utility. Four hundred and forty-eight asymptomatic patients (61±12 years and 69% men) with ≥3+ primary mitral regurgitation and preserved left ventricular ejection fraction, who underwent mitral valve surgery (92% repair) at our center between 2005 and 2008, were studied. Baseline clinical and echocardiographic data (including LV-GLS using Velocity Vector Imaging, Siemens, PA) were recorded. The Society of Thoracic Surgeons score was calculated. The primary outcome was death. Mean Society of Thoracic Surgeons score, left ventricular ejection fraction, mitral effective regurgitant orifice, indexed LV end-diastolic volume, and right ventricular systolic pressure were 4±1%, 62±3%, 0.55±0.2 cm(2), 58±13 cc/m(2), and 37±15 mm Hg, respectively. Forty-five percent of patients had flail. Median log-transformed BNP and LV-GLS were 4.04 (absolute brain natriuretic peptide: 60 pg/dL) and -20.7%. At 7.7±2 years, death occurred in 41 patients (9%; 0% at 30 days). On Cox analysis, a higher Society of Thoracic Surgeons score (hazard ratio 1.55), higher baseline right ventricular systolic pressure (hazard ratio 1.11), more abnormal LV-GLS (hazard ratio 1.17), and higher median log-transformed BNP (hazard ratio 2.26) were associated with worse longer-term survival (all P<0.01). Addition of LV-GLS and median log-transformed BNP to a clinical model (Society of Thoracic Surgeons score and baseline right ventricular systolic pressure) provided incremental prognostic utility (χ(2) for longer-term mortality increased from 31-47 to 61; P<0.001). In asymptomatic patients with significant primary mitral regurgitation and preserved left ventricular ejection fraction who underwent mitral valve

  10. Right paracardiac mass due to organized pericardial hematoma around retained epicardial pacing wires following aortic valve replacement.

    PubMed

    Kapoor, Aditya; Syal, Sanjiv; Gupta, Nirmal; Gupta, Archana

    2011-07-01

    The use of temporary epicardial pacing wires during cardiac surgery is a routine procedure and has been associated with low morbidity. We describe a rare case of right paracardiac mass due to organized pericardial hematoma with right atrial compression around the epicardial pacing wires left in-situ, presenting three months following aortic valve replacement surgery. The case highlights the fact that such delayed complications can rarely occur around retained epicardial pacing wires following open heart surgery especially in patients on oral anticoagulants. The clinician should be alert to such an occurrence and during follow-up echocardiography always pay attention not only to the valve and ventricular function, but also to the pericardial and extra-pericardial space.

  11. Transcatheter JenaValve Implantation in a Stentless Prosthesis: A Challenging Case After 4 Previous Aortic Procedures.

    PubMed

    Sponga, Sandro; Mazzaro, Enzo; Bagur, Rodrigo; Livi, Ugolino

    2017-04-01

    A 40-year-old man underwent 4 aortic surgeries because of endocarditis and subsequent prosthesis dehiscence. At the last recurrence he presented with acute severe aortic regurgitation of a Pericarbon Freedom (LivaNova plc, London, UK) stentless bioprosthesis and a morphologically disarranged aortic root. He also presented with left ventricular dysfunction and a very low origin of the left coronary artery. Therefore, a fifth redo aortic valve replacement was considered at high surgical risk. Accordingly, before listing the patient for a heart transplantation, a transcatheter valve-in-valve implantation with the JenaValve (JenaValve Technology, GmbH, Munich, Germany) prosthesis was performed. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  12. Check valve

    DOEpatents

    Upton, Hubert Allen; Garcia, Pablo

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion.

  13. Check valve

    DOEpatents

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  14. A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves.

    PubMed

    Sotiropoulos, Fotis; Borazjani, Iman

    2009-03-01

    In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid-structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment.

  15. A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves

    PubMed Central

    Borazjani, Iman

    2009-01-01

    In nearly half of the heart valve replacement surgeries performed annually, surgeons prefer to implant bileaflet mechanical heart valves (BMHV) because of their durability and long life span. All current BMHV designs, however, are prone to thromboembolic complications and implant recipients need to be on a life-long anticoagulant medication regiment. Non-physiologic flow patterns and turbulence generated by the valve leaflets are believed to be the major culprit for the increased risk of thromboembolism in BMHV implant recipients. In this paper, we review recent advances in developing predictive fluid–structure interaction (FSI) algorithms that can simulate BMHV flows at physiologic conditions and at resolution sufficiently fine to start probing the links between hemodynamics and blood-cell damage. Numerical simulations have provided the first glimpse into the complex hemodynamic environment experienced by blood cells downstream of the valve leaflets and successfully resolved for the first time the experimentally observed explosive transition to a turbulent-like state at the start of the decelerating flow phase. The simulations have also resolved a number of subtle features of experimentally observed valve kinematics, such as the asymmetric opening and closing of the leaflets and the leaflet rebound during closing. The paper also discusses a future research agenda toward developing a powerful patient-specific computational framework for optimizing valve design and implantation in a virtual surgery environment. PMID:19194734

  16. Recovery of atrial function after atrial compartment operation for chronic atrial fibrillation in mitral valve disease.

    PubMed

    Shyu, K G; Cheng, J J; Chen, J J; Lin, J L; Lin, F Y; Tseng, Y Z; Kuan, P; Lien, W P

    1994-08-01

    We prospectively studied the recovery of atrial function after atrial compartment operation and mitral valve surgery in patients with chronic atrial fibrillation caused by mitral valve disease. Chronic atrial fibrillation is the most common arrhythmia in mitral valve disease. This arrhythmia is associated with excessive morbidity and mortality. Mitral valve surgery alone rarely eliminates it. Twenty-two patients underwent mitral valve surgery and a new surgical method, atrial compartment operation. Doppler echocardiography was performed in all patients before operation and at 1 week and 2 and 6 months after operation in the successful cardioversion group. Peak early diastolic (E) and atrial (A) filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves were measured. Sinus rhythm was restored immediately after operation in 91% of patients and was maintained for > 1 week in 15 (68%) of 22 patients and > 6 months in 14 (64%) of 22. Eleven of 15 patients had left atrial paralysis (A/E integral ratio 0) at 1 week and 6 of 14 patients at 2 months. Nine of 15 patients had right atrial paralysis (A/E integral ratio 0) at 1 week and 1 of 14 patients at 2 months. Both left and right atrial contractile function (presence of an A wave on Doppler findings) was detected at 6 months in 14 patients. Mean (+/- SD) peak atrial filling velocity of the mitral valve was 15 +/- 26 cm/s at 1 week, 38 +/- 39 cm/s at 2 months and 93 +/- 32 cm/s at 6 months (p < 0.001). Mean peak atrial filling velocity of the tricuspid valve was 14 +/- 19 cm/s at 1 week, 33 +/- 19 cm/s at 2 months and 50 +/- 19 cm/s at 6 months (p < 0.001). Peak early diastolic and atrial filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves increased significantly from 1 week to 6 months. Chronic atrial fibrillation in mitral valve disease can often be eliminated by atrial compartment operation. No surgical mortality or significant

  17. Initial Experience and Early Results of Mitral Valve Repair with Cardiocel Pericardial Patch.

    PubMed

    Tomšič, Anton; Bissessar, Daniella D; van Brakel, Thomas J; Marsan, Nina Ajmone; Klautz, Robert J M; Palmen, Meindert

    2018-06-07

    To assess the performance of a tissue engineering process-treated bovine pericardium patch (CardioCel) in the setting of reconstructive mitral valve surgery. Between 3/2014 and 4/2016, 30 patients (57.2±14.3 years, 27% female) underwent mitral valve leaflet repair with a CardioCel patch. Perioperative mortality was 7% (2 patients, non-graft-related). In 28 remaining patients, pre-discharge echocardiography demonstrated good repaired valve function. At a mean follow-up of 1.7±0.9 years, 3 additional deaths occurred (2 due to infective endocarditis, 1 non-cardiac related). On follow-up echocardiography [follow-up time 1.7±0.8 years, available for 26/28 (93%) hospital survivors], recurrent regurgitation was seen in 2 patients (both infective endocarditis) and 1 underwent reoperation (no infection at the level of patch repair was observed). In the remaining patients, the most recent echocardiogram demonstrated ≤mild regurgitation and stable gradients. The thickness and echodensity of the implanted patch on follow-up echocardiograms were comparable with postoperative echocardiograms. Initial results of the CardioCel patch in mitral valve repair surgery are satisfactory. The resistance to infection and late degeneration will need to be assessed in the future. Copyright © 2018. Published by Elsevier Inc.

  18. Cost-effectiveness of aortic valve replacement in the elderly: an introductory study.

    PubMed

    Wu, YingXing; Jin, Ruyun; Gao, Guangqiang; Grunkemeier, Gary L; Starr, Albert

    2007-03-01

    With increased life expectancy and improved technology, valve replacement is being offered to increasing numbers of elderly patients with satisfactory clinical results. By using standard econometric techniques, we estimated the relative cost-effectiveness of aortic valve replacement by drawing on a large prospective database at our institution. By using aortic valve replacement as an example, this introductory report paves the way to more definitive studies of these issues in the future. From 1961 to 2003, 4617 adult patients underwent aortic valve replacement at our service. These patients were provided with a prospective lifetime follow-up. As of 2005, these patients had accumulated 31,671 patient-years of follow-up (maximum 41 years) and had returned 22,396 yearly questionnaires. A statistical model was used to estimate the future life years of patients who are currently alive. In the absence of direct estimates of utility, quality-adjusted life years were estimated from New York Heart Association class. The cost-effectiveness ratio was calculated by the patient's age at surgery. The overall cost-effectiveness ratio was approximately 13,528 dollars per quality-adjusted life year gained. The cost-effectiveness ratio increased according to age at surgery, up to 19,826 dollars per quality-adjusted life year for octogenarians and 27,182 dollars per quality-adjusted life year for nonagenarians. Given the limited scope of this introductory study, aortic valve replacement is cost-effective for all age groups and is very cost-effective for all but the most elderly according to standard econometric rules of thumb.

  19. Comparison of Levosimendan, Milrinone and Dobutamine in treating Low Cardiac Output Syndrome Following Valve Replacement Surgeries with Cardiopulmonary Bypass

    PubMed Central

    Sunny; Karim, Habib Md Reazaul; Saikia, Manuj Kumar; Bhattacharyya, Prithwis; Dey, Samarjit

    2016-01-01

    Introduction Low Cardiac Output Syndrome (LCOS) following Cardiopulmonary Bypass (CPB) is common and associated with increased mortality. Maintenance of adequate cardiac output is one of the primary objectives in management of such patients. Aim To compare Levosimendan, Milrinone and Dobutamine for the treatment of LCOS after CPB in patients who underwent valve replacement surgeries. Materials and Methods Sixty eligible patients meeting LCOS were allocated into three treatment groups: Group A-Levosimendan (loading dose 10μg/kg over 10 minutes, followed by 0.1μg/kg/min); Group B-Milrinone (loading dose 50 mcg/kg over 10 minutes followed by 0.5mcg/kg/min) and Group C-Dobutamine @ 5μg/kg/min to achieve target cardiac index (CI) of > 2.5 L/min/m2. In case of failure, other drugs were added as required. Hemodynamic parameters were monitored using EV1000TM clinical platform till 30 minutes post CPB. INSTAT software was used for statistics and p<0.05 was considered significant. Results The mean±standard deviation of time taken by Dobutamine, Levosimendan and Milrinone to bring the CI to target were 11.1±8.79, 11.3±6.34 and 16.62±9.33 minutes respectively (p=0.064). Levosimendan was equally effective in increasing and maintaining adequate CI as compared to Dobutamine (p>0.05). Levosimendan and Milrinone increased MAP (Mean Arterial Pressure) equally while Dobutamine was more effective as compared to both Levosimendan and Milrinone 20th minute onwards (p<0.01). Milrinone was less effective in increasing the stroke volume as compared to Dobutamine and Levosimendan while Dobutamine and Levosimendan were equally effective. There was no difference in the HR (Heart Rate) achieved with all these three drugs. Conclusion Levosimendan is equally effective to Dobutamine and better than Milrinone for the treatment of LCOS following CPB in patients undergoing valve replacement surgeries. PMID:28208977

  20. [Foreign body in the tricuspid valve with valvular insufficiency and right-left shunt].

    PubMed

    Delebarre, P; Augustin-Normand, C; Capronier, C; Cramer, J; Godeau, P; Letac, B; Forman, J; Maurice, P; Ourbak, P

    1987-05-01

    We present the case of a 50-year old man who progressively developed tricuspid valve insufficiency with opening of a patent foramen ovale responsible for right-to-left shunt with polycythaemia. The tricuspid valve insufficiency was due to a foreign body, probably of surgical origin as suggested by its radiological image and by the patient's previous history. It would have been introduced, far away from the tricuspid valve (compound fracture of the wrist), several years previously. At surgery, we found the foreign body embedded in the valve system. As a possible mechanism for the mutilation, an undiagnosed endocarditis was suspected but could not be confirmed. Three cases tricuspid endocarditis (with foreign bodies in the right ventricle) and 3 cases of asymptomatic tricuspid valve foreign bodies have been published. Fifty-five cases of foreign bodies introduced peripherally and migrated into the heart, the pericardium and the pulmonary artery are reviewed.

  1. Anterior urethral valves: an uncommon cause of obstructive uropathy in children.

    PubMed

    Kibar, Yusuf; Coban, Hidayet; Irkilata, H Cem; Erdemir, Fikret; Seckin, Bedrettin; Dayanc, Murat

    2007-10-01

    Anterior urethral valves (AUV) are rare entities generally described in case reports. They are an uncommon cause of lower urinary tract obstruction in children and can be difficult to diagnose. In the present study, we present our experience in four children with AUV along with a literature review. We retrospectively identified four children with AUV presented between 1998 and 2005 at age 4-9 years. Hematuria, urinary tract infection and weak voiding stream were the most common symptoms. Voiding cystourethrography (VCUG) confirmed the diagnosis of AUV. On cystourethroscopy, cusp-like valves in the anterior urethra were seen in all children. Transurethral endoscopic resection of the valves was carried out in three children using a pediatric resectoscope. In one child with a massive anterior urethral diverticulum, open resection of the valve, diverticulectomy and urethroplasty were performed. All patients were cured, none had complications as a result of surgery, and all reported a normal urinary stream at follow-up. Children with poor stream and recurrent infections should be evaluated carefully and anterior urethral valves should be considered in differential diagnosis of obstructive lesions.

  2. Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation

    PubMed Central

    Spina, Roberto; Anthony, Chris; Muller, David WM

    2015-01-01

    Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674

  3. Mechanisms of valve competency after mitral valve annuloplasty for ischaemic mitral regurgitation using the Geoform ring: insights from three-dimensional echocardiography.

    PubMed

    Armen, Todd A; Vandse, Rashmi; Crestanello, Juan A; Raman, Subha V; Bickle, Katherine M; Nathan, Nadia S

    2009-01-01

    Left ventricular remodelling leads to functional mitral regurgitation resulting from annular dilatation, leaflet tethering, tenting, and decreased leaflet coaptation. Mitral valve annuloplasty restores valve competency, improving the patient's functional status and ventricular function. This study was designed to evaluate the mechanisms underlying mitral valve competency after the implantation of a Geoform annuloplasty ring using three-dimensional (3D) echocardiography. Seven patients (mean age of 65 years) with ischaemic mitral regurgitation underwent mitral valve annuloplasty with the Geoform ring and coronary artery bypass surgery. Pre- and post-operative 3D echocardiograms were performed. Following mitral annuloplasty, mitral regurgitation decreased from 3.4+/-0.2 to 0.9+/-0.3 (P-value<0.0001), mitral valve tenting volume from 13+/-1.7 to 3.2+/-0.3 mL (P-value<0.001), annulus area from 12.6+/-1.0 to 3.3+/-0.2 cm2 (P-value<0.0001), valve circumference from 13+/-0.5 to 7.3+/-0.3 cm (P-value<0.0001), septolateral distance from 2.1+/-0.1 to 1.4+/-0.06 cm (P-value<0.01) and intercommissural distance from 3.4+/-0.1 to 2.7+/-0.03 cm (P-value<0.03). There was significant decrease in the septolateral distance at the level of A2-P2 with respect to other regions. These geometric changes were associated with the improvement in the NYHA class from 3.1+/-0.3 to 1.3+/-0.3 (P-value<0.002). The mitral valve annuloplasty with the Geoform ring restores leaflet coaptation and eliminates mitral regurgitation by effectively modifying the mitral annular geometry.

  4. The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.

    PubMed

    Silaschi, Miriam; Conradi, Lenard; Wendler, Olaf; Schlingloff, Friederike; Kappert, Utz; Rastan, Ardawan J; Baumbach, Hardy; Holzhey, David; Eichinger, Walter; Bader, Ralf; Treede, Hendrik

    2018-06-01

    We present 1-year outcomes of the post-market registry of a next-generation transcatheter heart valve used for aortic regurgitation (AR). Transcatheter aortic valve replacement (TAVR) is routine in high-risk patients with aortic stenosis but is not recommended for AR. The JenaValve™ (JenaValve Technology GmbH, Munich, Germany) overcomes technical challenges in AR patients through a leaflet clipping mechanism. The JenaValve EvalUation of Long Term Performance and Safety In PaTients with SEvere Aortic Stenosis oR Aortic Insufficiency (JUPITER) Registry is a European study to evaluate safety and effectiveness of this THV. From 2012-2015, 30 patients with AR were enrolled. Mean age was 74.4 ± 9.3 years. Procedural success was 96.7% (29/30). One patient was converted to open surgery. No annular rupture or coronary ostia obstruction occurred. Mortality at 30 days was 10.0% (3/30). Combined safety endpoint was met in 13.3% (4/30). Paravalvular regurgitation was not present/trivial in 84.6% (22/26) and mild in 15.4% (4/26). Rate of permanent pacemaker implantation was 3.8% (1/26). One-year Kaplan-Meier survival was 79.9%, one-year combined efficacy was 73.1% (19/30). No further strokes were observed during 1 year of follow-up. The JenaValve overcomes technical challenges of TAVR in AR through a clipping mechanism. We report satisfactory outcomes of a multicenter registry using the JenaValve for predominant AR, as rate of THV embolization, residual AR and permanent pacemaker implantation was low. One-year results using the JenaValve for AR encourage its use for this indication. © 2017 Wiley Periodicals, Inc.

  5. Preoperative planning with three-dimensional reconstruction of patient's anatomy, rapid prototyping and simulation for endoscopic mitral valve repair.

    PubMed

    Sardari Nia, Peyman; Heuts, Samuel; Daemen, Jean; Luyten, Peter; Vainer, Jindrich; Hoorntje, Jan; Cheriex, Emile; Maessen, Jos

    2017-02-01

    Mitral valve repair performed by an experienced surgeon is superior to mitral valve replacement for degenerative mitral valve disease; however, many surgeons are still deterred from adapting this procedure because of a steep learning curve. Simulation-based training and planning could improve the surgical performance and reduce the learning curve. The aim of this study was to develop a patient-specific simulation for mitral valve repair and provide a proof of concept of personalized medicine in a patient prospectively planned for mitral valve surgery. A 65-year old male with severe symptomatic mitral valve regurgitation was referred to our mitral valve heart team. On the basis of three-dimensional (3D) transoesophageal echocardiography and computed tomography, 3D reconstructions of the patient's anatomy were constructed. By navigating through these reconstructions, the repair options and surgical access were chosen (minimally invasive repair). Using rapid prototyping and negative mould fabrication, we developed a process to cast a patient-specific mitral valve silicone replica for preoperative repair in a high-fidelity simulator. Mitral valve and negative mould were printed in systole to capture the pathology when the valve closes. A patient-specific mitral valve silicone replica was casted and mounted in the simulator. All repair techniques could be performed in the simulator to choose the best repair strategy. As the valve was printed in systole, no special testing other than adjusting the coaptation area was required. Subsequently, the patient was operated, mitral valve pathology was validated and repair was successfully done as in the simulation. The patient-specific simulation and planning could be applied for surgical training, starting the (minimally invasive) mitral valve repair programme, planning of complex cases and the evaluation of new interventional techniques. The personalized medicine could be a possible pathway towards enhancing reproducibility

  6. Computerized system for the follow-up of patients with heart valve replacements.

    PubMed

    Bain, W H; Fyfe, I C; Rodger, R A

    1985-04-01

    A system is described which will accept, store, retrieve and analyze information on large numbers of patients who undergo valve replacement surgery. The purpose of the database is to yield readily available facts concerning the patient's clinical course, prosthetic valve function, length of survival, and incidence of complications. The system uses the Apple Macintosh computer, which is one of the current examples of small, desk-top microprocessors. The software for the input, editing and analysis programs has been written by a professional software writer in close collaboration with a cardiac surgeon. Its content is based on 8 years' experience of computer-based valve follow-up. The system is inexpensive and has proved easy to use in practice.

  7. Percutaneous Tricuspid Valve Regurgitation Repair With the MitraClip Device Using an Edge-to-Edge Bicuspidization Technique.

    PubMed

    Gafoor, Sameer; Petrescu, O Madalina; Lehr, Eric J; Puls, Charles; Zhang, Ming; Petersen, John L; Olsen, John V; Penev, Irina; Agrawal, Mayank; Sharma, Rahul; Barnhart, Glenn

    2017-03-01

    Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.

  8. Patterns and determinants of functional and absolute iron deficiency in patients undergoing cardiac rehabilitation following heart surgery.

    PubMed

    Tramarin, Roberto; Pistuddi, Valeria; Maresca, Luigi; Pavesi, Marco; Castelvecchio, Serenella; Menicanti, Lorenzo; de Vincentiis, Carlo; Ranucci, Marco

    2017-05-01

    Background Anaemia and iron deficiency are frequent following major surgery. The present study aims to identify the iron deficiency patterns in cardiac surgery patients at their admission to a cardiac rehabilitation programme, and to determine which perioperative risk factor(s) may be associated with functional and absolute iron deficiency. Design This was a retrospective study on prospectively collected data. Methods The patient population included 339 patients. Functional iron deficiency was defined in the presence of transferrin saturation <20% and serum ferritin ≥100 µg/l. Absolute iron deficiency was defined in the presence of serum ferritin values <100 µg/l. Results Functional iron deficiency was found in 62.9% of patients and absolute iron deficiency in 10% of the patients. At a multivariable analysis, absolute iron deficiency was significantly ( p = 0.001) associated with mechanical prosthesis mitral valve replacement (odds ratio 5.4, 95% confidence interval 1.9-15) and tissue valve aortic valve replacement (odds ratio 4.5, 95% confidence interval 1.9-11). In mitral valve surgery, mitral repair carried a significant ( p = 0.013) lower risk of absolute iron deficiency (4.4%) than mitral valve replacement with tissue valves (8.3%) or mechanical prostheses (22.5%). Postoperative outcome did not differ between patients with functional iron deficiency and patients without iron deficiency; patients with absolute iron deficiency had a significantly ( p = 0.017) longer postoperative hospital stay (median 11 days) than patients without iron deficiency (median nine days) or with functional iron deficiency (median eight days). Conclusions Absolute iron deficiency following cardiac surgery is more frequent in heart valve surgery and is associated with a prolonged hospital stay. Routine screening for iron deficiency at admission in the cardiac rehabilitation unit is suggested.

  9. Impact of wait times on the effectiveness of transcatheter aortic valve replacement in severe aortic valve disease: a discrete event simulation model.

    PubMed

    Wijeysundera, Harindra C; Wong, William W L; Bennell, Maria C; Fremes, Stephen E; Radhakrishnan, Sam; Peterson, Mark; Ko, Dennis T

    2014-10-01

    There is increasing demand for transcatheter aortic valve replacement (TAVR) as the primary treatment option for patients with severe aortic stenosis who are high-risk surgical candidates or inoperable. We used mathematical simulation models to estimate the hypothetical effectiveness of TAVR with increasing wait times. We applied discrete event modelling, using data from the Placement of Aortic Transcatheter Valves (PARTNER) trials. We compared TAVR with medical therapy in the inoperable cohort, and compared TAVR to conventional aortic valve surgery in the high-risk cohort. One-year mortality and wait-time deaths were calculated in different scenarios by varying TAVR wait times from 10 days to 180 days, while maintaining a constant wait time for surgery at a mean of 15.6 days. In the inoperable cohort, the 1-year mortality for medical therapy was 50%. When the TAVR wait time was 10 days, the TAVR wait-time mortality was 1.9% with a 1-year mortality of 31.5%. TAVR wait-time deaths increased to 28.9% with a 180-day wait, with a 1-year mortality of 41.4%. In the high-risk cohort, the wait-time deaths and 1-year mortality for the surgical patients were 2.5% and 27%, respectively. The TAVR wait-time deaths increased from 2.2% with a 10-day wait to 22.4% with a 180-day wait, and a corresponding increase in 1-year mortality from 24.5% to 32.6%. Mortality with TAVR exceeded surgery when TAVR wait times exceeded 60 days. Modest increases in TAVR wait times have a substantial effect on the effectiveness of TAVR in inoperable patients and high-risk surgical candidates. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  10. Fast-Acting Valve

    NASA Technical Reports Server (NTRS)

    Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)

    2003-01-01

    A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.

  11. First uses of HAART 300 rings for aortic valve repair in Poland - 4 case studies.

    PubMed

    Juściński, Jacek H; Koprowski, Andrzej; Kołaczkowska, Magdalena; Kowalik, Maciej M; Rogowski, Jan A; Rankin, James S

    2018-03-01

    Aortic valve reconstructions using geometric annuloplasty rings HAART 300/200 open new era in aortic valve surgery. The HAART technology resizes, reshapes, stabilizes and simplifies aortic valve repair. The HAART aortic repair rings are designed to be implanted directly into aortic annulus (under aortic valve leaflets). We present first in Poland 4 cases of aortic valve reconstructions using geometric annuloplasty rings HAART 300. Two patients had type IA aortic insufficiency (due to El-Khoury classification) - they were treated by HAART 300 ring insertion and ascending aorta prosthesis implantation. Third patient, Marfan with type IB aortic insufficiency was repaired by HAART 300 ring implantation followed by remodeling (Yacoub) procedure. Fourth patient with type II aortic insufficiency (due to RCC prolapse) was repaired by HAART 300 implantation and cusp plication. All patients shows good results on 6 months postoperative 3D TTE examinations. Presented technique is reproducible and simplify aortic valve reconstructions.

  12. The valve choice in tricuspid valve replacement: 25 years of experience.

    PubMed

    Van Nooten, G J; Caes, F L; François, K J; Taeymans, Y; Primo, G; Wellens, F; Leclerq, J L; Deuvaert, F E

    1995-01-01

    This study reviews 146 consecutive patients who underwent tricuspid valve replacement (TVR) with 69 bioprostheses (porcine and bovine pericardial) and 77 mechanical ball, disc or bileaflet valves between 1967 and 1987. The mean age was 51.4 +/- 12.1 years. Preoperatively, 97% were in New York Heart Association (NYHA) functional class III or more and over 40% had undergone previous cardiac surgery. Hospital mortality was high (16.1%). Incremental risk factors for hospital death were preoperative icterus (P < 0.01), hepatomegaly (P = 0.02), NYHA functional class IV (P = 0.02) and male sex (P = 0.04) (univariate analysis). Ninety-eight percent of the hospital survivors were followed up for a mean of 92 months. Cumulative follow-up added up to 955 patient-years. There were 70 late deaths. The actuarial survival rate was 74% at 60 months and less than 25% at 14 years. Incremental risk factors for late death indicated by univariate analysis were the type of tricuspid prosthesis (Smel-off-Cutter and Kay-Shiley prostheses) (P = 0.04), the type of operative myocardial protection (normothermia and coronary perfusion) (P = 0.05) and preoperative NYHA functional class IV (P = 0.05). We conclude that TVR carries a high operative risk and poor long-term survival, both influenced by preoperative and perioperative variables. Bearing in mind the poor prognosis for TVR, we prefer a large-sized bioprosthesis, in view of its initial good durability and low risk of valve-related events. However, in patients with good life expectancy, a bileaflet mechanical prosthesis may be an acceptable alternative.

  13. Adapting to living with a mechanical aortic heart valve: a phenomenographic study.

    PubMed

    Oterhals, Kjersti; Fridlund, Bengt; Nordrehaug, Jan Erik; Haaverstad, Rune; Norekvål, Tone M

    2013-09-01

    To describe how patients adapt to living with a mechanical aortic heart valve. Aortic valve replacement with a mechanical prosthesis is preferred for patients with life expectancy of more than 10 years as they are more durable than bioprosthetic valves. Mechanical valves have some disadvantages, such as higher risk of thrombosis and embolism, increased risk of bleeding related to lifelong oral anticoagulation treatment and noise from the valve. An explorative design with a phenomenographic approach was employed. An explorative design with a phenomenographic approach was applied. Interviews were conducted over 4 months during 2010-2011 with 20 strategically sampled patients, aged 24-74 years having undergone aortic valve replacement with mechanical prosthesis during the last 10 years. Patients adapted to living with a mechanical aortic heart valve in four ways: 'The competent patient' wanted to stay in control of his/her life. 'The adjusted patient' considered the implications of having a mechanical aortic valve as part of his/her daily life. 'The unaware patient' was not aware of warfarin-diet-medication interactions. 'The worried patient' was bothered with the oral anticoagulation and annoyed by the sound of the valve. Patients moved between the different ways of adapting. The oral anticoagulation therapy was considered the most troublesome consequence, but also the sound of the valve was difficult to accept. Patient counselling and adequate follow-up can make patients with mechanical aortic heart valves more confident and competent to manage their own health. We recommend that patients should participate in a rehabilitation programme following cardiac surgery. © 2013 Blackwell Publishing Ltd.

  14. A new paradigm for obtaining marketing approval for pediatric-sized prosthetic heart valves.

    PubMed

    Yoganathan, Ajit P; Fogel, Mark; Gamble, Susan; Morton, Michael; Schmidt, Paul; Secunda, Jeff; Vidmar, Sara; Del Nido, Pedro

    2013-10-01

    Congenital heart valve disease is one of the most common abnormalities in children. There are limited technological solutions available for treating children with congenital heart valve diseases. The aim of this study is to provide the details of the consensus reached in terms of pediatric definitions, design approach, in vitro testing, and clinical trials, which may be used as guidance for developing prosthetic heart valves for the pediatric indication. In stark contrast to the various designs of adult-sized replacement valves available in the market, there are no Food and Drug Administration (FDA)-approved prosthetic heart valves available for use in the pediatric population. There is a pressing need for FDA-approved pediatric valve devices in the United States. The pediatric patient population has been typically excluded from replacement heart valve trials for several reasons. In January 2010, heart valve manufacturers and pediatric clinicians collaborated with academicians and FDA staff in a workshop to suggest ways to successfully evaluate pediatric prosthetic valves and conduct pediatric clinical trials to provide acceptable heart valve replacement options for this patient population. Recommendations, derived from ISO 5840:2005 and the 2010 FDA Draft Replacement Heart Valve Guidance, are provided for hydrodynamic, durability, and fatigue testing. The article specifically addresses in vitro and premarket and postmarket approval clinical studies that should be considered by a heart valve manufacturer for obtaining regulatory approval of pediatric sizes of prosthetic heart valve designs that are already approved for adult clinical use. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  15. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.

    PubMed

    Miller, Justin G; Li, Ming; Mazilu, Dumitru; Hunt, Tim; Horvath, Keith A

    2016-05-01

    To demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model. The CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach. Two imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function. Our results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  16. All you need to know about the tricuspid valve: Tricuspid valve imaging and tricuspid regurgitation analysis.

    PubMed

    Huttin, Olivier; Voilliot, Damien; Mandry, Damien; Venner, Clément; Juillière, Yves; Selton-Suty, Christine

    2016-01-01

    The acknowledgment of tricuspid regurgitation (TR) as a stand-alone and progressive entity, worsening the prognosis of patients whatever its aetiology, has led to renewed interest in the tricuspid-right ventricular complex. The tricuspid valve (TV) is a complex, dynamic and changing structure. As the TV is not easy to analyse, three-dimensional imaging, cardiac magnetic resonance imaging and computed tomography scans may add to two-dimensional transthoracic and transoesophageal echocardiographic data in the analysis of TR. Not only the severity of TR, but also its mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. TR is functional and is a satellite of left-sided heart disease and/or elevated pulmonary artery pressure most of the time; a particular form is characterized by TR worsening after left-sided valve surgery, which has been shown to impair patient prognosis. A better description of TV anatomy and function by multimodality imaging should help with the appropriate selection of patients who will benefit from either surgical TV repair/replacement or a percutaneous procedure for TR, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Intraoperative assessment of mitral valve area after mitral valve repair: comparison of different methods.

    PubMed

    Maslow, Andrew; Gemignani, Anthony; Singh, Arun; Mahmood, Feroze; Poppas, Athena

    2011-04-01

    In the present study, 3 different methods to measure the mitral valve area (MVA) after mitral valve repair (MVRep) were studied. Data obtained immediately after repair were compared with postoperative data. The objective was to determine the feasibility and correlation between intraoperative and postoperative MVA data. A prospective study. A tertiary care medical center. Twenty-five elective adult surgical patients scheduled for MVRep. Echocardiographic data included MVAs obtained using the pressure half-time (PHT), 2-dimensional planimetry (2D-PLAN), and the continuity equation (CE). These data were obtained immediately after cardiopulmonary bypass and were compared with data obtained before hospital discharge (transthoracic echocardiogram 1) and 6 to 12 months after surgery (transthoracic echocardiogram 2). Intraoperative care was guided by hemodynamic goals designed to optimize cardiac function. The data show good agreement and correlation between MVA obtained with PHT and 2D-PLAN within and between each time period. MVA data obtained with the CE in the postoperative period were lower than and did not correlate or agree as well with other MVA data. The MVA recorded immediately after valve repair, using PHT, correlated and agreed with MVA data obtained in the postoperative period. These results contrast with previously published data and could highlight the impact of hemodynamic function during the assessment of MVA. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Relation of Mitral Valve Surgery Volume to Repair Rate, Durability, and Survival.

    PubMed

    Chikwe, Joanna; Toyoda, Nana; Anyanwu, Anelechi C; Itagaki, Shinobu; Egorova, Natalia N; Boateng, Percy; El-Eshmawi, Ahmed; Adams, David H

    2017-04-24

    Degenerative mitral valve repair rates remain highly variable, despite established benefits of repair over replacement. The contribution of surgeon-specific factors is poorly defined. This study evaluated the influence of surgeon case volume on degenerative mitral valve repair rates and outcomes. A mandatory New York State database was queried and 5,475 patients were identified with degenerative mitral disease who underwent mitral valve operations between 2002 and 2013. Mitral repair rates, mitral reoperations within 12 months of repair, and survival were analyzed using multivariable Cox modeling and restricted cubic spline function. Median annual surgeon volume of any mitral operations was 10 (range 1 to 230), with a mean repair rate of 55% (n = 20,797 of 38,128). In the subgroup of patients with degenerative disease, the mean repair rate was 67% (n = 3,660 of 5,475), with a range of 0% to 100%. Mean repair rates ranged from 48% (n = 179 of 370) for surgeons with total annual volumes of ≤10 mitral operations to 77% (n = 1,710 of 2,216) for surgeons with total annual volumes of >50 mitral operations (p < 0.001). Higher total annual surgeon volume was associated with increased repair rates of degenerative mitral valve disease (adjusted odds ratio [OR]: 1.13 for every additional 10 mitral operations; 95% confidence interval [CI]: 1.10 to 1.17; p < 0.001); a steady decrease in reoperation risk until 25 total mitral operations annually; and improved 1-year survival (adjusted hazard ratio: 0.95 for every additional 10 operations; 95% CI: 0.92 to 0.98; p = 0.001). For surgeons with a total annual volume of ≤25 mitral operations, repair rates were higher (63.8%; n = 180 of 282) if they operated in the same institution as a surgeon with total annual mitral volumes of >50 and degenerative mitral valve repair rates of >70%, compared with surgeons operating in the other institutions (51.3%; n = 580 of 1,130) (adjusted OR: 1.79; 95% CI: 1.24 to 2.60; p

  19. Increased dietary intake of vitamin A promotes aortic valve calcification in vivo.

    PubMed

    Huk, Danielle J; Hammond, Harriet L; Kegechika, Hiroyuki; Lincoln, Joy

    2013-02-01

    Calcific aortic valve disease (CAVD) is a major public health problem with no effective treatment available other than surgery. We previously showed that mature heart valves calcify in response to retinoic acid (RA) treatment through downregulation of the SRY transcription factor Sox9. In this study, we investigated the effects of excess vitamin A and its metabolite RA on heart valve structure and function in vivo and examined the molecular mechanisms of RA signaling during the calcification process in vitro. Using a combination of approaches, we defined calcific aortic valve disease pathogenesis in mice fed 200 IU/g and 20 IU/g of retinyl palmitate for 12 months at molecular, cellular, and functional levels. We show that mice fed excess vitamin A develop aortic valve stenosis and leaflet calcification associated with increased expression of osteogenic genes and decreased expression of cartilaginous markers. Using a pharmacological approach, we show that RA-mediated Sox9 repression and calcification is regulated by classical RA signaling and requires both RA and retinoid X receptors. Our studies demonstrate that excess vitamin A dietary intake promotes heart valve calcification in vivo. Therefore suggesting that hypervitaminosis A could serve as a new risk factor of calcific aortic valve disease in the human population.

  20. Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions.

    PubMed

    Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T

    2015-01-01

    Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Whereas much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells.

  1. Current Progress in Tissue Engineering of Heart Valves: Multiscale Problems, Multiscale Solutions

    PubMed Central

    Cheung, Daniel Y; Duan, Bin; Butcher, Jonathan T.

    2016-01-01

    Introduction Heart valve disease is an increasingly prevalent and clinically serious condition. There are no clinically effective biological diagnostics or treatment strategies. The only recourse available is replacement with a prosthetic valve, but the inability of these devices to grow or respond biologically to their environments necessitates multiple resizing surgeries and life-long coagulation treatment, especially in children. Tissue engineering has a unique opportunity to impact heart valve disease by providing a living valve conduit, capable of growth and biological integration. Areas covered This review will cover current tissue engineering strategies in fabricating heart valves and their progress towards the clinic, including molded scaffolds using naturally-derived or synthetic polymers, decellularization, electrospinning, 3D bioprinting, hybrid techniques, and in vivo engineering. Expert opinion While much progress has been made to create functional living heart valves, a clinically viable product is not yet realized. The next leap in engineered living heart valves will require a deeper understanding of how the natural multi-scale structural and biological heterogeneity of the tissue ensures its efficient function. Related, improved fabrication strategies must be developed that can replicate this de novo complexity, which is likely instructive for appropriate cell differentiation and remodeling whether seeded with autologous stem cells in vitro or endogenously recruited cells. PMID:26027436

  2. Alar batten cartilage graft: treatment of internal and external nasal valve collapse.

    PubMed

    Cervelli, Valerio; Spallone, Diana; Bottini, J Davide; Silvi, Erminia; Gentile, Pietro; Curcio, Beniamino; Pascali, Michele

    2009-07-01

    The aim of this study was to describe the efficacy of alar batten graft in correcting internal and external nasal valve collapse (i.n.v. and e.n.v.) and evaluate the functional and aesthetic results. From July 2006 to September 2008, 80 patients (54 females and 26 males) underwent alar batten cartilage grafting. The patients were divided into three groups: (1) 55 patients with iatrogenic nasal valve collapse (80% i.n.v., 20% e.n.v.), (2) 15 patients with posttraumatic nasal valve collapse (45% i.n.v., 55% e.n.v.), and (3) 10 patients with congenital nasal valve collapse (100% e.n.v.). Patients were evaluated at 6, 12, 24, and some at 36 months after surgery. The final follow-up was at least 24 months. The results of this study revealed a significant increase in the size of the aperture at the internal or external nasal valve after the application of alar batten grafts. All the patients noted improvement in their nasal airway breathing and in their cosmetic appearance. No major complication was observed. The alar batten graft is a simple, versatile technique for long-term reshaping, repositioning, and reconstruction of the nasal valve collapse.

  3. Comparison of Outcomes of Resident-performed Ahmed Valve Implantation vs Trabeculectomy

    PubMed Central

    Kammerdiener, Leah L; Wannamaker, Kendall W; Fan, Jie; Sharpe, Elizabeth D

    2016-01-01

    ABSTRACT Aims: To compare outcomes of resident-performed Ahmed valve surgery vs trabeculectomy in a Veteran Affairs medical facility. Materials and methods: A retrospective cohort of 103 eyes in 91 patients receiving Ahmed valve (valve) or trabeculectomy (trab) performed at a Veterans Administration Medical Center by residents in their third year of training. The primary outcomes included intraocular pressure (IOP), treatment failure, and complications over 1 year. Results: Of 103 eyes, 44 received valve and 59 received trab. Primary open-angle glaucoma was primary diagnosis more often in trab, while neovascular glaucoma predominated in the valve group (p < 0.001). Preoperative mean IOP was 35.1 ± 11.8 and 24.5 ± 7.1 mm Hg for valve and trabeculectomy respectively (p < 0.001), but at 1 year the IOP difference between groups was not statistically significant (p = 0.064). Overall, 11 (25.0%) and 11 (18.6%) eyes met any criteria for failure for valve and trab respectively. At 1 year, 22.5% of valves had IOP > 21 mm Hg vs only 4.3% of trab (p = 0.02). Complications were infrequent. There were no intraoperative complications for valve, whereas five for trab. Most common immediate complication for valve was hyphema. Both groups had low rates of choroidal effusions and reoperation. Conclusion: Ahmed valve implantation and trabeculectomy produce significant reductions in IOP when performed by residents-in-training. Valves tend to be used more frequently in patients with secondary glaucoma. Although complication profiles differ between procedures, both are safe and well tolerated when performed by resident physicians. Clinical significance: This study provides support for evidence-based patient counseling that supervised, resident-performed Ahmed valve implantation and trabeculectomy are indeed safe and effective. How to cite this article: Sharpe RA, Kammerdiener LL, Wannamaker KW, Fan J, Sharpe ED. Comparison of Outcomes of Resident-performed Ahmed Valve Implantation vs

  4. Pseudomonas aeruginosa Infective Endocarditis Following Aortic Valve Implantation: A Note of Caution

    PubMed Central

    Dapás, Juan Ignacio; Rivero, Cynthia; Burgos, Pablo; Vila, Andrea

    2016-01-01

    Transcatheter aortic valve implantation (TAVI) is an alternative treatment for severe aortic valve stenosis (AS) in patients with prohibitive risk for surgical aortic valve replacement (SAVR). Prosthetic valve endocarditis (PVE) is a rare complication of this relatively novel procedure and current guidelines do not include specific recommendations for its treatment. We report a case of PVE due to Pseudomonas aeruginosa after TAVI that required SAVR, with successful outcome. PVE usually occurs during the first year after TAVI and entails a high mortality risk because patients eligible for this min-imally invasive procedure are fragile (i.e. advanced age and/or severe comorbidities). Additionally, clinical presentation may be atypical or subtle and transesophageal echocardiogram (TEE) may not be conclusive, which delays diagnosis and treatment worsening the prognosis. This case highlights that open SAVR might be ultimately indicated as part of treatment for TAVI-PVE despite a high-risk surgery score. PMID:27014375

  5. Contemporary experience with surgical treatment of aortic valve disease in children.

    PubMed

    Khan, Muhammad S; Samayoa, Andres X; Chen, Diane W; Petit, Christopher J; Fraser, Charles D

    2013-09-01

    Surgical treatment of aortic valve (AoV) disease in childhood involves complex decisions particularly in very small patients. There is no consensus regarding the optimum surgical option. The objective of this review was to analyze a contemporary experience of AoV surgery in a large children's hospital. A retrospective review of children (aged ≤ 18 years) undergoing AoV repair or replacement from June 1995 to December 2011 was carried out. A total of 285 AoV operations (97 repairs, 188 replacements) were performed on 241 patients. Hospital survival for repair was 98% and for replacements was 97%. At follow-up of repairs, there were 16 (17%) reoperations and 3 (3%) late deaths. Follow-up of AoV replacements demonstrated 31 (16%) reoperations (homograft 27, autograft 3, mechanical 1) and 8 (4%) late deaths (homograft 5, autograft 2, mechanical 1). Freedom from reintervention or death (FRD) was found to be lower in repairs for infants (P = .048) and truncal valves (P < .05). For AoV replacements, infants and patients who had concomitant CHD or homografts (P < .0001) had lower FRD. Cox regression analysis for AoV replacements identified infants and homograft root replacements at a higher risk for death/reoperation. AoV repairs and replacements were generally found to be associated with low death and reoperation rates at long-term follow-up. Infants had a lower freedom from reintervention or death after either an AoV repair or replacement, although truncal valve repairs and AoV replacement in patients with concomitant CHD were associated with lower valve survival. Among the valve options, homograft root replacement had a higher risk of death/reoperation and lowest freedom from reintervention or death. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. The effect of intravitreal bevacizumab injection before Ahmed valve implantation in patients with neovascular glaucoma.

    PubMed

    Kang, Jung Youb; Nam, Ki Yup; Lee, Sang Joon; Lee, Seung Uk

    2014-08-01

    To evaluate the effect of intravitreal bevacizumab (IVB) before Ahmed valve implantation for treatment of neovascular glaucoma (NVG). This study is a retrospective, comparative, consecutive case series. The study group consisted of 27 eyes of 26 patients with NVG who underwent an Ahmed valve implantation. Thirteen eyes were treated with Ahmed valve implantation alone (control group), and 14 eyes were treated with a combination of preoperative IVB injection and Ahmed valve implantation (IVB group). Visual acuity, intraocular pressure (IOP), number of anti-glaucoma medications, surgical complications, and success rate were compared between the two groups. There were no significant differences in preoperative characteristics between the two groups. Visual acuity at 1, 2 weeks, and 1 month after surgery were significantly better in the IVB group (p = 0.038, 0.034, and 0.032, respectively). Hyphema associated with Ahmed valve implantation occurred significantly less in the IVB group (p = 0.016). On the other hand, the mean IOP and number of anti-glaucoma medications at all follow-up periods were similar between the two groups. Kaplan-Meier survival analysis showed the probability of success 6 months after surgery as 71.4 % in the IVB group and 84.6 % in the control group. No significant difference in success rate was found between the groups (p = 0.422). IVB before Ahmed valve implantation for treatment of NVG reduced the incidence of hyphema. In this retrospective study, IVB provided better visual outcome in the early postoperative periods but did not significantly improve mean IOP, number of anti-glaucoma medications, or success rate.

  7. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside

    PubMed Central

    Saxon, John T; Allen, Keith B; Cohen, David J

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832

  8. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    PubMed

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  9. Durability of hand-sewn valves in the right ventricular outlet.

    PubMed

    Nunn, Graham R; Bennetts, Jayme; Onikul, Ella

    2008-08-01

    The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained

  10. No effect of a homoeopathic combination of Arnica montana and Bryonia alba on bleeding, inflammation, and ischaemia after aortic valve surgery.

    PubMed

    Cornu, Catherine; Joseph, Pierre; Gaillard, Ségolène; Bauer, Christian; Vedrinne, Catherine; Bissery, Alvine; Melot, Ghislaine; Bossard, Nadine; Belon, Philippe; Lehot, Jean-Jacques

    2010-02-01

    " Arnica montana is a popular homoeopathic treatment with potential haemostatic and anti-inflammatory properties. A homoeopathic combination of A. montana and Bryonia alba was used in aortic valve surgery to evaluate its effectiveness in reducing bleeding, inflammation, pain and myocardial ischaemia. One day before surgery, 92 adult patients were randomly assigned to a double-blind parallel trial with either homoeopathic granules or a matching placebo until 4 days after surgery. The primary outcome was the volume of blood/liquid in the drains at their removal. The secondary outcomes included postoperative blood/liquid losses at 12 and 24 h as well as C-reactive protein (CRP), pain, temperature and plasma troponin Ic. At 12 h and 24 h after surgery, then at drain removal, blood losses in homoeopathy and placebo groups were not statistically significant (362 +/- 218, 520 +/- 269 and 640 +/- 297 ml vs. 456 +/- 440, 620 +/- 477 and 796 +/- 717 ml; P= 0.19, 0.23 and 0.35, respectively). The statistical modelling did not show significantly different patterns of CRP, troponin and body temperature changes or of pain perception. The number of transfused packed red cells was not significantly different either (P= 0.58). Two patients from each group died during the study period and the number of serious adverse events was not statistically different (six in homoeopathy vs. 10 in placebo groups; Fisher's exact test P= 0.41). In the study setting, there was no evidence of effects of A. montana and B. alba combination on bleeding, inflammation, pain or myocardial ischaemia.

  11. Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery.

    PubMed

    Kohler, Philipp; Kuster, Stefan P; Bloemberg, Guido; Schulthess, Bettina; Frank, Michelle; Tanner, Felix C; Rössle, Matthias; Böni, Christian; Falk, Volkmar; Wilhelm, Markus J; Sommerstein, Rami; Achermann, Yvonne; Ten Oever, Jaap; Debast, Sylvia B; Wolfhagen, Maurice J H M; Brandon Bravo Bruinsma, George J; Vos, Margreet C; Bogers, Ad; Serr, Annerose; Beyersdorf, Friedhelm; Sax, Hugo; Böttger, Erik C; Weber, Rainer; van Ingen, Jakko; Wagner, Dirk; Hasse, Barbara

    2015-10-21

    We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater-cooler unit of the heart-lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Interdisciplinary care and follow-up of all patients was documented by the study team. Patients' characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36-76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5-40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogens. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  12. Aortic valve replacement in a dialysis-dependent Jehovah's Witness: successful use of a minicircuit, microplegia, and multimodality blood conservation technique

    PubMed Central

    Sutton, Steve W.; Marcel, Randy

    2007-01-01

    We present the first reported case of an aortic valve replacement operation without blood transfusion in a 62-year-old Jehovah's Witness with dialysis-dependent chronic renal failure, severe anemia, severe aortic stenosis, and symptomatic angina with minimal exertion after an accident in which she suffered fractures of both her right arm and leg. She underwent successful valve replacement surgery after preoperative stabilization of her fractures and high-dose erythropoietin and iron supplement therapy preoperatively and postoperatively. The intraoperative blood conservation technique included a novel approach with a miniature cardiopulmonary bypass circuit and microplegia with limited hemodilution. High-risk valve surgery in patients who are Jehovah's Witnesses can be successful with a carefully planned multimodality blood conservation strategy. PMID:17256040

  13. Complete versus partial preservation of mitral valve apparatus during mitral valve replacement: meta-analysis and meta-regression of 1535 patients.

    PubMed

    Sá, Michel Pompeu Barros De Oliveira; Escobar, Rodrigo Renda; Ferraz, Paulo Ernando; Vasconcelos, Frederico Pires; Lima, Ricardo Carvalho

    2013-11-01

    To determine if there is any real difference between complete preservation (CP) and partial preservation (PP) of the mitral valve apparatus during mitral valve replacement (MVR) in terms of hard outcomes. MEDLINE, EMBASE, CENTRAL/CCTR, SciELO, LILACS, Google Scholar and reference lists of relevant articles were searched for clinical studies that compared outcomes [30-day mortality, postoperative low cardiac output syndrome (LCOS), 5-year mortality or left ventricle ejection fraction (LVEF) before and after surgery] between MVR-CP vs MVR-PP during MVR until July 2012. The principal summary measures were odds ratios (ORs) with 95% confidence interval (CI)--for categorical variables (30-day mortality, postoperative LCOS, 5-year mortality); difference means and standard error (SE)--for continuous variables (LVEF before and after surgery) and P values (that will be considered statistically significant when <0.05). The ORs were combined across studies using DerSimonian-Laird random effects weighted model. The same procedure was executed for continuous variables, taking into consideration the difference in means. Eight studies (2 randomized and 6 non-randomized) were identified and included a total of 1535 patients (597 for MVR-CP and 938 for MVR-PP). There was no significant difference between MVR-CP or MVR-PP groups in the risk for 30-day mortality (OR 0.870; 95% CI 0.50-1.52; P = 0.63) or postoperative LCOS (OR 0.35; 95% CI 0.11-1.08 and P = 0.07) or 5-year mortality (OR 0.70; 95% CI 0.43-1.14; P = 0.15). Taking into consideration LVEF, neither MVR-CP nor MVR-CP demonstrated a statistically significant improvement in LVEF before and after surgery, and both strategies were not different from each other. No publication bias was observed. We found evidence that argues against any superiority between both techniques of preservation (complete or partial) of mitral valve apparatus during MVR.

  14. Do prices reflect the costs of cardiac surgery in the elderly?

    PubMed

    Coelho, Pedro; Rodrigues, Vanessa; Miranda, Luís; Fragata, José; Pita Barros, Pedro

    2017-01-01

    Payment for cardiac surgery in Portugal is based on a contract agreement between hospitals and the health ministry. Our aim was to compare the prices paid according to this contract agreement with calculated costs in a population of patients aged ≥65 years undergoing cardiac surgery in one hospital department. Data on 250 patients operated between September 2011 and September 2012 were prospectively collected. The procedures studied were coronary artery bypass graft surgery (CABG) (n=67), valve surgery (n=156) and combined CABG and valve surgery (n=27). Costs were calculated by two methods: micro-costing when feasible and mean length of stay otherwise. Price information was provided by the hospital administration and calculated using the hospital's mean case-mix. Thirty-day mortality was 3.2%. Mean EuroSCORE I was 5.97 (standard deviation [SD] 4.5%), significantly lower for CABG (p<0.01). Mean intensive care unit stay was 3.27 days (SD 4.7) and mean hospital stay was 9.92 days (SD 6.30), both significantly shorter for CABG. Calculated costs for CABG were €6539.17 (SD 3990.26), for valve surgery €8289.72 (SD 3319.93) and for combined CABG and valve surgery €11 498.24 (SD 10 470.57). The payment for each patient was €4732.38 in 2011 and €4678.66 in 2012 based on the case-mix index of the hospital group, which was 2.06 in 2011 and 2.21 in 2012; however, the case-mix in our sample was 6.48 in 2011 and 6.26 in 2012. The price paid for each patient was lower than the calculated costs. Prices would be higher than costs if the case-mix of the sample had been used. Costs were significantly lower for CABG. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Illness Perception Profiles and Their Association with 10-Year Survival Following Cardiac Valve Replacement.

    PubMed

    Crawshaw, Jacob; Rimington, Helen; Weinman, John; Chilcot, Joseph

    2015-10-01

    The aim of the present study was to examine whether profiles of illness perceptions are associated with 10-year survival following cardiac valve replacement surgery. Illness perceptions were evaluated in 204 cardiac patients awaiting first-time valve replacement and again 1 year post-operatively using cluster analysis. All-cause mortality was recorded over a 10-year period. At 1 year, 136 patients were grouped into one of four profiles (stable positive, stable negative, changed from positive to negative, changed from negative to positive). The median follow-up was 3063 days (78 deaths). After controlling for clinical covariates, including markers of function, patients who changed illness perceptions from positive to negative beliefs 1 year post-surgery had an increased mortality risk (hazard ratio (HR) = 3.2, 95% confidence interval (CI) 1.2-8.3, p = .02) compared to patients who held positive stable perceptions. Following cardiac valve replacement, developing negative illness perceptions over the first post-operative year predicts long-term mortality. Early screening and intervention to alter this pattern of beliefs may be beneficial.

  16. CardiaMed mechanical valve: mid-term results of a multicenter clinical trial.

    PubMed

    Nazarov, Vladimir M; Zheleznev, Sergey I; Bogachev-Prokophiev, Alexandr V; Afanasyev, Alexandr V; Nemchenko, Eugene V; Jeltovskiy, Yuri V; Lavinyukov, Sergey O

    2014-01-01

    Prosthesis choice is a major concern in valvular surgery. A multicenter clinical trial was performed to assess the efficacy and safety of the CardiaMed prosthetic heart valve. The study enrolled 420 patients who underwent mitral (209) or aortic (211) valve replacement from 2003 to 2004 at 7 institutions in Russia, and who were followed up from 2006 to 2011. The mean age was 52.2 ± 10.2 years (range, 12-78 years), 47.4% were female, and 99.05% completed the study. The maximum observation term was 7.5 years (2188.5 patient-years); 1081.6 patient-years for aortic and 1106.9 patient-years for mitral valve replacement. The overall 7-year survival rate was 85.1%  ± 3.7%; 86.1%  ± 4.8% and 84.4%  ± 5.4% for aortic and mitral valve replacement, respectively. The 7-year freedom from valve-related death was 93.9%  ± 3.7% and 94.5%  ± 3.2% for aortic and mitral valve replacement, respectively. When early mortality (<30 days) was excluded, these rates were 94.8%  ± 3.1% and 93.8%  ± 3.82%, respectively. Linearized valve-dependent complication rates were determined for structural valve failure (0%/patient-year overall), thrombosis (0.63%/patient-year, all for mitral valve replacement), thromboembolic complications including transient neurologic deficits (0.13%/patient-year overall, 0.5%/patient-year for aortic valve replacement, 0.8%/patient-year for mitral valve replacement), hemorrhagic bleeding (0.64%/patient-year overall, 0.55%/patient-year for aortic valve replacement, 0.09%/patient-year for mitral valve replacement), prosthetic endocarditis (0.28%/patient-year overall, 0.28%/patient-year for aortic valve replacement, 0%/patient-year for mitral valve replacement), and hemolysis (0%/patient-year overall). The CardiaMed mechanical heart valve prostheses meets world standards of safety and efficacy.

  17. Transcatheter Aortic Valve Implantation for Treatment of Aortic Valve Stenosis: A Health Technology Assessment

    PubMed Central

    Sehatzadeh, Shayan; Tu, Hong-Anh; Holubowich, Corinne; Higgins, Caroline

    2016-01-01

    Background Surgical aortic valve replacement (SAVR) is the gold standard for treating aortic valve stenosis. It is a major operation that requires sternotomy and the use of a heart-lung bypass machine, but in appropriately selected patients with symptomatic, severe aortic valve stenosis, the benefits of SAVR usually outweigh the harms. Transcatheter aortic valve implantation (TAVI) is a less invasive procedure that allows an artificial valve to be implanted over the poorly functioning valve. Methods We identified and analyzed randomized controlled trials that evaluated the effectiveness and safety of TAVI compared with SAVR or balloon aortic valvuloplasty and were published before September 2015. The quality of the body of evidence for each outcome was examined according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. The overall quality was determined to be high, moderate, low, or very low using a step-wise, structural methodology. We also developed a Markov decision-analytic model to assess the cost-effectiveness of TAVI compared with SAVR over a 5-year time horizon, and we conducted a 5-year budget impact analysis. Results Rates of cardiovascular and all-cause mortality were similar for the TAVI and SAVR groups in all studies except one, which reported significantly lower all-cause mortality in the TAVI group and a higher rate of stroke in the SAVR group. Trials of high-risk patients who were not suitable candidates for SAVR showed significantly better survival with TAVI than with balloon aortic valvuloplasty. Median survival in the TAVI group was 31 months, compared with 11.7 months in the balloon aortic valvuloplasty group. Compared with SAVR, TAVI was associated with a significantly higher risk of stroke, major vascular complications, paravalvular aortic regurgitation, and the need for a permanent pacemaker. SAVR was associated with a higher risk of bleeding. Transapical TAVI was associated with higher

  18. Atrioventricular valve repair in patients with single-ventricle physiology: mechanisms, techniques of repair, and clinical outcomes.

    PubMed

    Honjo, Osami; Mertens, Luc; Van Arsdell, Glen S

    2011-01-01

    Significant atrioventricular (AV) valve insufficiency in patient with single ventricle-physiology is strongly associated with poor survival. Herein we discuss the etiology and mechanism of development of significant AV valve insufficiency in patients with single-ventricle physiology, surgical indication and repair techniques, and clinical outcomes along with our 10-year surgical experience. Our recent clinical series and literature review indicate that it is of prime importance to appreciate the high incidence and clinical effect of the structural abnormalities of AV valve. Valve repair at stage II palliation may minimize the period of volume overload, thereby potentially preserving post-repair ventricular function. Since 85% of the AV valve insufficiency was associated with structural abnormalities, inspection of an AV valve that has more than mild to moderate insufficiency is recommended because they are not likely to be successfully treated with volume unloading surgery alone. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. High Risk Aortic Valve Replacement - The Challenges of Multiple Treatment Strategies with an Evolving Technology.

    PubMed

    Booth, K; Beattie, R; McBride, M; Manoharan, G; Spence, M; Jones, J M

    2016-01-01

    Deciding on the optimal treatment strategy for high risk aortic valve replacement is challenging. Transcatheter Aortic Valve implantation (TAVI) has been available in our centre as an alternative treatment modality for patients since 2008. We present our early experience of TAVI and SAVR (surgical Aortic Valve Replacement) in high risk patients who required SAVR because TAVI could not be performed. The database for Surgical aortic valve and Transcatheter aortic valve replacement referrals was interrogated to identify relevant patients. Survival to hospital discharge was 95.5% in the forty five patients who had SAVR when TAVI was deemed technically unsuitable. One year survival was 86%. Defining who is appropriate for TAVI or high risk SAVR is challenging and multidisciplinary team discussion has never been more prudent in this field of evolving technology with ever decreasing risks of surgery. The introduction of TAVI at our institution has seen a rise in our surgical caseload by approximately by 25%. Overall, the option of aortic valve intervention is being offered to more patients in general which is a substantial benefit in the treatment of aortic valve disease.

  20. Redo mitral surgery using the Estech endoclamp.

    PubMed

    Van Nooten, G; Van Belleghem, Y; Van Overbeke, H; Caes, F; François, K; De Pauw, M; De Rijcke, F; Poelaert, J

    2001-01-01

    Redo-CABG surgery remains extremely hazardous in the presence of open bypass grafts. In our patients with mitral valve pathology with open and well-functioning bypass grafts, we explored alternative approaches in order to avoid damage to the grafts by extensive dissection and direct clamping of the ascending aorta. The "Estech procedure," which uses the Estech remote access perfusion (RAP) endoclamp catheter (Estech Inc., Danville, CA), was selected for these patients. From January 1998 to January 2000, 10 patients underwent an Estech procedure for redo mitral surgery. All patients had previous cardiac operations such as coronary artery bypass grafting (CABG) and/or mitral valve procedures. The Estech procedure consisted of an anterior left thoracotomy and peripheral cannulation at femoral site using the Estech endovascular balloon technique. The series was comprised of seven mitral valve replacements, two valve reconstructions, and one closure of a paravalvular leak. One procedure had to be converted to a standard re-sternotomy due to extreme arteriosclerosis of the descending aorta with plaque dislocation at the time of catheter insertion. However, no damage was inflicted to the open bypass grafts. The follow-up period ranged from six to 30 months and was 100% complete. We encountered one hospital death in our group, which was due to a late post-operative intestinal infarction and multiple organ failure (MOF), and was not procedure related. As expected, morbidity was high in this compromised cohort, but no late death has occurred prior to submission of this article. All survivors progressed to an acceptable NYHA functional class. The excellent results in this complex patient group inspired us to use the Estech procedure as a standard approach for redo mitral surgery.

  1. Early Outcomes of Sutureless Aortic Valves.

    PubMed

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-06-01

    In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  2. Early Outcomes of Sutureless Aortic Valves

    PubMed Central

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-01-01

    Background In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time. PMID:27298793

  3. [Percutaneous stented pulmonary valve implantation].

    PubMed

    Ersbøll, Mads; Søndergaard, Lars

    2010-03-29

    A number of congenital cardiac malformations involve the right ventricular outflow tract and are often treated with a biological valved conduit. The longevity of these valves is limited due to graft degeneration, which causes progressive valvular dysfunction and subsequently right ventricular failure. Due to the young age of these patients, repeat surgery can be expected and this has motivated the invention of the percutaneous stented valve implantation (PPVR). We retrospectively examined 13 patients (mean age 26 +/- 10 years) treated with PPVR between 2006 and 2008 at our institution. Indications for PPVR were conduit dysfunction with severe stenosis and/or regurgitation, reduced exercise capacity and right ventricular dilatation. In all patients, immediate haemodynamic improvement occurred with full valvular competence after PPVR. The pressure gradient was reduced from 43 (+/- 15) mmHg to 12 (+/- 7) mmHg (p = 0,05) in patients with combined regurgitation and stenosis and 47 (+/- 14) mmHg to 12 (+/- 2) mmHg (p = 0,05) in patients with isolated stenosis. At mean follow-up after 141 (+/- 140) days, no reintervention had been required. Significant haemodynamic and clinical improvement occurred after PPVR in all patients and no major complications occurred. PPVR remains a safe and minimally invasive treatment modality, and our study demonstrates that PPVR can be safely performed in a low volume setting.

  4. Ahmed glaucoma valve in children: A review☆

    PubMed Central

    Nassiri, Nariman; Nouri-Mahdavi, Kouros; Coleman, Anne L.

    2011-01-01

    Pediatric glaucoma is potentially a blinding disease. Although goniotomy and trabeculotomy are associated with good early success rates, eventually 20% of these procedures fail and many children will require additional surgery to control the IOP in the long-term. In this review, we reported that adequate IOP control can be achieved with the placement of Ahmed glaucoma valve and can last 5 or more years. However, most patients will need one or more glaucoma medications at some point after surgery. In addition, the implants may be associated with pupillary irregularities, lenticular opacification as well as tube-related complications, particularly in the first year of life, as the globe is enlarging with age. PMID:23960945

  5. Trans-apical aortic valve implantation using a new self-expandable bioprosthesis: initial outcomes.

    PubMed

    Kempfert, Jörg; Rastan, Ardawan J; Beyersdorf, Friedhelm; Schönburg, Markus; Schuler, Gerhard; Sorg, Stefan; Mohr, Friedrich-W; Walther, Thomas

    2011-11-01

    Trans-apical aortic valve implantation (TA-AVI) has evolved into a standard approach for high-risk, elderly patients using the balloon-expandable Edwards SAPIEN™ prosthesis. As an alternative device, a self-expanding sub-coronary trans-apical bioprosthesis was evaluated. The Symetis Acurate™ trans-catheter heart valve is composed of a porcine biologic valve attached to a self-expandable nitinol stent. It allows for anatomical orientation, and facilitates intuitive implantation providing tactile feedback. Three valves sizes were available to treat patients with an annular diameter between 21 and 27mm. Since November 2009, a total of 40 patients have been treated at three sites. Patient age was 82.8±4 years, 60% were female, logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 21.5±10.9% and Society of Thoracic Surgeons (STS) Score was 9.0±4.6%. All implants were delivered successfully in the intra-annular and sub-coronary position off pump. One patient was converted to conventional surgery due to coronary impingement; post-dilatation was performed in 45% of patients; and two patients required the SAPIEN™ valve in valve implantation. Echocardiographic and angiographic control revealed no/trivial aortic incompetence (AI) in 59%, mild AI in 33.3%, and moderate AI in 7.7% of the patients. Three patients died within 30 days from a non-valve-related cause (respiratory), the patient converted did not recover from right-heart failure, and one patient died on day 19 due to unclear reasons. There was one incidence of new-onset atrioventricular (AV) block requiring pacemaker implantation. Two patients suffered a stroke (one secondary and the other intraprocedural). Transvalvular gradients were maximum 29.4±10.7mmHg and mean 14.3±6.8mmHg. The initial clinical results indicate a relatively straightforward implantation procedure and good functional results after trans-apical implantation of the Symetis Acurate™ device. Copyright © 2011

  6. Control Valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Wayne R.

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between amore » first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.« less

  7. Single coronary artery with bicuspid aortic valve stenosis and aneurysm of the ascending aorta: report of a case.

    PubMed

    Ishida, Narihiro; Shimabukuro, Katsuya; Matsuno, Yukihiro; Ogura, Hiroki; Takemura, Hirofumi

    2014-03-01

    A 73-year-old man with a severely stenosed bicuspid valve and an aneurysm of the ascending aorta underwent valve and aortic surgery. Preoperative imaging revealed a single coronary artery arising from the right side of the sinus of Valsalva and a branch that perfused into the left side of the heart to pass through the front of the pulmonary artery. We replaced the aortic valve and ascending aorta, painstakingly avoiding damage to the coronary artery and obstruction of the sole coronary ostium.

  8. Gas dynamic model of electrothermal thrusters of small spacecraft and possibility of applying microwave heating of a working

    NASA Astrophysics Data System (ADS)

    Blinov, V. N.; Shalay, V. V.; Vavilov, I. S.; Kositsin, V. V.; Ruban, V. I.; Lykyanchik, A. I.; Yachmenev, P. S.; Vlasov, A. S.

    2017-06-01

    This paper is devoted to development and approbation of the gas dynamic model of ammonia thruster with low power consumption and ultra small thrust for picosatellite weighing up to 5 kg and possibility of applying microwave heating of a working fluid. It is shown, that simplest electrothermal thruster consisting of propellant tank, solenoid valve, expension cavity and heating chamber can provide ultra small trust due to gas dynamic processes and small heat supply. The results of the study set tasks for further design of small spacecrafts microwave generators.

  9. Current-driven non-linear magnetodynamics in exchange-biased spin valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seinige, Heidi; Wang, Cheng; Tsoi, Maxim, E-mail: tsoi@physics.utexas.edu

    2015-05-07

    This work investigates the excitation of parametric resonance in exchange-biased spin valves (EBSVs). Using a mechanical point contact, high density dc and microwave currents were injected into the EBSV sample. Observing the reflected microwave power and the small rectification voltage that develops across the contact allows detecting the current-driven magnetodynamics not only in the bulk sample but originating exclusively from the small contact region. In addition to ferromagnetic resonance (FMR), parametric resonance at twice the natural FMR frequency was observed. In contrast to FMR, this non-linear resonance was excited only in the vicinity of the point contact where current densitiesmore » are high. Power-dependent measurements displayed a typical threshold-like behavior of parametric resonance and a broadening of the instability region with increasing power. Parametric resonance showed a linear shift as a function of applied dc bias which is consistent with the field-like spin-transfer torque induced by current on magnetic moments in EBSV.« less

  10. Causes of death from the randomized CoreValve US Pivotal High-Risk Trial.

    PubMed

    Gaudiani, Vincent; Deeb, G Michael; Popma, Jeffrey J; Adams, David H; Gleason, Thomas G; Conte, John V; Zorn, George L; Hermiller, James B; Chetcuti, Stan; Mumtaz, Mubashir; Yakubov, Steven J; Kleiman, Neal S; Huang, Jian; Reardon, Michael J

    2017-06-01

    Explore causes and timing of death from the CoreValve US Pivotal High-Risk Trial. An independent clinical events committee adjudicated causes of death, followed by post hoc hierarchical classification. Baseline characteristics, early outcomes, and causes of death were evaluated for 3 time periods (selected based on threshold of surgical 30-day mortality and on the differences in the continuous hazard between the 2 groups): early (0-30 days), recovery (31-120 days), and late (121-365 days). Differences in the rate of death were evident only during the recovery period (31-120 days), whereas 15 patients undergoing transcatheter aortic valve replacement (TAVR) (4.0%) and 27 surgical aortic valve replacement (SAVR) patients (7.9%) died (P = .025). This mortality difference was largely driven by higher rates of technical failure, surgical complications, and lack of recovery following surgery. From 0 to 30 days, the causes of death were more technical failures in the TAVR group and lack of recovery in the SAVR group. Mortality in the late period (121-365 days) in both arms was most commonly ascribed to other circumstances, comprising death from medical complications from comorbid disease. Mortality at 1 year in the CoreValve US Pivotal High-Risk Trial favored TAVR over SAVR. The major contributor was that more SAVR patients died during the recovery period (31-121 days), likely affected by the overall influence of physical stress associated with surgery. Similar rates of technical failure and complications were observed between the 2 groups. This suggests that early TAVR results can improve with technical refinements and that high-risk surgical patients will benefit from reducing complications. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Left Atrial Wall Dissection: A Rare Sequela of Native-Valve Endocarditis

    PubMed Central

    Isbitan, Ahmad; Roushdy, Alaa; Shamoon, Fayez

    2015-01-01

    Left atrial wall dissection is a rare condition; most cases are iatrogenic after mitral valve surgery. A few have been reported as sequelae of blunt chest trauma, acute myocardial infarction, and invasive cardiac procedures. On occasion, infective endocarditis causes left atrial wall dissection. We report a highly unusual case in which a 41-year-old man presented with native mitral valve infective endocarditis that had caused left atrial free-wall dissection. Although our patient died within an hour of presentation, we obtained what we consider to be a definitive diagnosis of a rare sequela, documented by transthoracic and transesophageal echocardiography. PMID:25873836

  12. Structure and function of the tricuspid and bicuspid regurgitant aortic valve: an echocardiographic study.

    PubMed

    Rönnerfalk, Mattias; Tamás, Éva

    2015-07-01

    The emerging new treatment options for aortic valve disease call for more sophisticated diagnostics. We aimed to describe the echocardiographic pathophysiology and characteristics of the purely regurgitant aortic valve in detail. Twenty-nine men, with chronic aortic regurgitation without concomitant heart disease referred for aortic valve intervention, underwent 2D transoesophageal echocardiographic (TEE) examination prior to surgery according to a previously published matrix. Measurements of the aortic valve apparatus in long and short axis view were made in systole and diastole and analysed off-line. The aortic valves were grouped as tricuspid (TAV) or bicuspid (BAV), and classified by regurgitation mechanism. Twenty-four examinations were eligible for analysis of which 13 presented TAV and 11 BAV. The regurgitation mechanism was classified as dilatation of the aorta in 6 cases, as prolapse in 11 cases and as poor cusp tissue quality or quantity in 7 cases. The ventriculo-aortic junction (VAJ) and valve opening were closely related (TAV r = 0.5, BAV r = 0.73) but no correlation was found between the VAJ and the maximal sinus diameter (maxSiD) or the sinotubular junction (STJ). However, the STJ and maxSiD were significantly related (TAV vs BAV: systole r = 0.9, r = 0.8; diastole r = 0.9, r = 0.7), forming an entity. The conjoined BAV cusps were shorter than the anterior cusps when closed (P = 0.002); the inter-commissural distances of the cusps in the BAV group were significantly different (P = 0.001 resp. 0.03) in both systole and diastole. The VAJ was independent of other aortic dimensions and should thereby be considered as a separate entity with influence on valve opening. The detailed 2D TEE measurements of this study add further important information to our knowledge about the function and echocardiographic anatomy of the pathological aortic valve and root either as a stand-alone examination or as a benchmark and complement to 3D echocardiography. This may

  13. Pannus-related prosthetic valve dysfunction. Case report

    PubMed Central

    MOLDOVAN, MARIA-SÎNZIANA; BEDELEANU, DANIELA; KOVACS, EMESE; CIUMĂRNEAN, LORENA; MOLNAR, ADRIAN

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction. PMID:27004041

  14. Pannus-related prosthetic valve dysfunction. Case report.

    PubMed

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  15. Nuclear radiation actuated valve

    DOEpatents

    Christiansen, David W.; Schively, Dixon P.

    1985-01-01

    A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.

  16. Salvaging catastrophe in transcatheter aortic valve implantation: rehearsal, preassigned roles, and emergency preparedness.

    PubMed

    Tam, Derrick Y; Jones, Philip M; Kiaii, Bob; Diamantouros, Pantelis; Teefy, Patrick; Bainbridge, Daniel; Cleland, Andrew; Fernandes, Philip; Chu, Michael W A

    2015-08-01

    Emergency rescue plans for acute complications during transcatheter aortic valve implantation (TAVI) commonly include cardiopulmonary resuscitation, femoro-femoral cardiopulmonary bypass (CPB), and hemodynamic stabilization before definitive intervention is achieved. Nevertheless, most cases of emergency resuscitation remain chaotic and disorganized and often take longer than necessary, even in experienced centres. We sought to determine which factors and procedures may be associated with improved patient outcomes when emergencies arise during TAVI. MEDLINE(®) and EMBASE™ were searched with the following key words: "TAVI" or "TAVR" or "transcatheter valve implantation" or "transcatheter valve replacement" and "emergency cardiac surgery" or "conversion". Two hundred seventeen articles met the criteria and were reviewed. Utilization of a formal emergency checklist by a multidisciplinary TAVI team may reduce procedural errors, smooth the transition to CPB, and ultimately speed the delivery of corrective measures including emergency cardiac surgery. A well-organized regularly-rehearsed emergency rescue plan that preassigns resuscitative roles may shorten the duration of patient instability and resuscitation and improve patient outcomes when catastrophe occurs in TAVI. The anesthesia team plays a central role in preventing, detecting, and treating intraprocedural complications during TAVI.

  17. Transcatheter aortic-valve replacement with a self-expanding prosthesis.

    PubMed

    Adams, David H; Popma, Jeffrey J; Reardon, Michael J; Yakubov, Steven J; Coselli, Joseph S; Deeb, G Michael; Gleason, Thomas G; Buchbinder, Maurice; Hermiller, James; Kleiman, Neal S; Chetcuti, Stan; Heiser, John; Merhi, William; Zorn, George; Tadros, Peter; Robinson, Newell; Petrossian, George; Hughes, G Chad; Harrison, J Kevin; Conte, John; Maini, Brijeshwar; Mumtaz, Mubashir; Chenoweth, Sharla; Oh, Jae K

    2014-05-08

    We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).

  18. The JUPITER registry: 1-year results of transapical aortic valve implantation using a second-generation transcatheter heart valve in patients with aortic stenosis.

    PubMed

    Silaschi, Miriam; Treede, Hendrik; Rastan, Ardawan J; Baumbach, Hardy; Beyersdorf, Friedhelm; Kappert, Utz; Eichinger, Walter; Rüter, Florian; de Kroon, Thomas L; Lange, Rüdiger; Ensminger, Stephan; Wendler, Olaf

    2016-11-01

    obstruction, annular rupture or with limited aortic valve calcification, the JenaValve might be preferable for implantation due to its clipping-mechanism engaging native aortic valve cusps for fixation with reduced radial forces of the self-expanding stent. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Provision, organization and models of heart valve clinics within The United Kingdom.

    PubMed

    Bhattacharyya, S; Pavitt, C; Lloyd, G; Chambers, J B

    2015-02-01

    Specialist clinics are recommended for the assessment and follow-up of patients with heart valve disease. We sought to identify the current provision of specialist valve clinics in UK. A database of all UK National Health Service hospitals was created. An online survey was distributed to each hospital to examine the model of heart valve clinic, patient population, provision of advanced imaging modalities and biochemical markers and provision of patient information services. Valve clinics were run in 48/228 (21%) hospitals, in 27/45 (60%) tertiary centres and 21/183 (11%) district hospitals. The survey was completed by 34 (71%). A consultant cardiologist ran the clinic in 19 (56%), a cardiac sonographer in 8 (24%), a nurse specialist in 3 (9%) and a hybrid model was used in 4 (12%). Patients with native valve disease were seen in 32 (94%), after heart valve surgery in 19 (56%), pre-/post-transcatheter valve intervention in 10 (29%) and with Marfan syndrome in 9(26%). Stress echocardiography, cardiac magnetic resonance imaging, computed tomography and positron emission tomography were available in 21 (62%), 19 (56%), 22 (65%) and 6 (18%) hospitals, respectively. There is an underprovision of specialist heart valve clinics within the UK, and there is a 5-fold difference between cardiac centres and district general hospitals. © The Author 2014. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Evaluation of simulation training in cardiothoracic surgery: the Senior Tour perspective.

    PubMed

    Fann, James I; Feins, Richard H; Hicks, George L; Nesbitt, Jonathan C; Hammon, John W; Crawford, Fred A

    2012-02-01

    The study objective was to introduce senior surgeons, referred to as members of the "Senior Tour," to simulation-based learning and evaluate ongoing simulation efforts in cardiothoracic surgery. Thirteen senior cardiothoracic surgeons participated in a 2½-day Senior Tour Meeting. Of 12 simulators, each participant focused on 6 cardiac (small vessel anastomosis, aortic cannulation, cardiopulmonary bypass, aortic valve replacement, mitral valve repair, and aortic root replacement) or 6 thoracic surgical simulators (hilar dissection, esophageal anastomosis, rigid bronchoscopy, video-assisted thoracoscopic surgery lobectomy, tracheal resection, and sleeve resection). The participants provided critical feedback regarding the realism and utility of the simulators, which served as the basis for a composite assessment of the simulators. All participants acknowledged that simulation may not provide a wholly immersive experience. For small vessel anastomosis, the portable chest model is less realistic compared with the porcine model, but is valuable in teaching anastomosis mechanics. The aortic cannulation model allows multiple cannulations and can serve as a thoracic aortic surgery model. The cardiopulmonary bypass simulator provides crisis management experience. The porcine aortic valve replacement, mitral valve annuloplasty, and aortic root models are realistic and permit standardized training. The hilar dissection model is subject to variability of porcine anatomy and fragility of the vascular structures. The realistic esophageal anastomosis simulator presents various approaches to esophageal anastomosis. The exercise associated with the rigid bronchoscopy model is brief, and adding additional procedures should be considered. The tracheal resection, sleeve resection, and video-assisted thoracoscopic surgery lobectomy models are highly realistic and simulate advanced maneuvers. By providing the necessary tools, such as task trainers and assessment instruments, the Senior

  1. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    PubMed

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  2. JenaValve.

    PubMed

    Treede, Hendrik; Rastan, Ardawan; Ferrari, Markus; Ensminger, Stephan; Figulla, Hans-Reiner; Mohr, Friedrich-Wilhelm

    2012-09-01

    The JenaValve is a next-generation TAVI device which consists of a well-proven porcine root valve mounted on a low-profile nitinol stent. Feeler guided positioning and clip fixation on the diseased leaflets allow for anatomically correct implantation of the device without rapid pacing. Safety and efficacy of transapical aortic valve implantation using the JenaValve were evaluated in a multicentre prospective study that showed good short and midterm results. The valve was CE-mark released in Europe in September 2011. A post-market registry ensures on-going and prospective data collection in "real-world" patients. The transfemoral JenaValve delivery system will be evaluated in a first-in-man study in the near future.

  3. Depressurization valve

    DOEpatents

    Skoda, G.I.

    1989-03-28

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring-preferably of the Belleville variety-acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion.

  4. Health Care–Associated Native Valve Endocarditis in Patients with no History of Injection Drug Use: Current Importance of Non-Nosocomial Acquisition

    PubMed Central

    Benito, Natividad; Miró, José M.; de Lazzari, Elisa; Cabell, Christopher H; del Río, Ana; Altclas, Javier; Commerford, Patrick; Delahaye, Francois; Dragulescu, Stefan; Giamarellou, Helen; Habib, Gilbert; Kamarulzaman, Adeeba; Kumar, A. Sampath; Nacinovich, Francisco M.; Suter, Fredy; Tribouilloy, Christophe; Venugopal, K; Moreno, Asuncion; Fowler, Vance G.

    2013-01-01

    Background The clinical profile and outcome of nosocomial and non-nosocomial health care–associated native valve endocarditis are not well defined. Objective To describe the prevalence, clinical characteristics, and outcomes of nosocomial and non-nosocomial health care–associated native valve endocarditis. Design Prospective observational study. Setting 61 hospitals in 28 countries. Patients Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the International Collaboration on Endocarditis–Prospective Cohort Study from June 2000 to August 2005. Measurements Characteristics of nosocomial and non-nosocomial health care–associated native valve endocarditis cases were described and compared with those cases acquired in the community. Results Health care–associated native valve endocarditis was present in 557 (34%) of 1622 patients with native valve endocarditis and no history of injection drug use (nosocomial native valve endocarditis 303 patients [54%]; non-nosocomial health care–associated native valve endocarditis 254 patients [46%]). Staphylococcus aureus was the most common cause of health care-associated native valve endocarditis (nosocomial native valve endocarditis, 47%; non-nosocomial health care–associated native valve endocarditis, 42%; p=0.3), with a notable proportion of methicillin-resistant S. aureus (nosocomial native valve endocarditis, 57%; non-nosocomial health care–associated native valve endocarditis, 41%; p=0.014). Patients with health care–associated native valve endocarditis had lower rates of cardiac surgery (41% health care–associated native valve endocarditis vs 51% community-acquired native valve endocarditis, p<0.001) and higher in-hospital mortality rates than patients with community-acquired native valve endocarditis (25% health care–associated native valve endocarditis vs. 13% community-acquired native valve endocarditis vs., p<0.001). Multivariable analysis

  5. IL-10 and ET-1 as biomarkers of rheumatic valve disease

    PubMed Central

    Leão, Sydney Correia; Lima, Maria Regina Menezes; do Nascimento, Hertaline Menezes; Octacilio-Silva, Shirlei; Rodrigues, Tania Maria de Andrade

    2014-01-01

    Objective To evaluate the immunological profile and gene expression of endothelin-1 (ET-1) in mitral valves of patients with rheumatic fever originated from a reference service in cardiovascular surgery. Methods This was a quantitative, observational and cross-sectional study. Thirty-five subjects (divided into four groups) participated in the study, 25 patients with chronic rheumatic heart disease and ten control subjects. The mean age of the sample studied was 34.5 years. Seventeen of them (48.58%) were male and 18 (51.42%) were female. Inflammatory cytokines (TNF-α, IL-4 and IL-10) were measured and ten mitral valves of patients who underwent first valve replacement were collected for determination of gene expression of endothelin-1 by real time PCR. Results Among the groups studied (patients vs. controls), there was a statistically significant difference in IL-10 levels (P=0.002), and no differences in other cytokines. Expression of endothelin-1 was observed in 70% of samples. Quantitatively, average of ET-1 expression was 62.85±25.63%. Conclusion Inflammatory cytokine IL-10 participates in the maintenance of chronicity of rheumatic fever in patients who underwent valve replacement and those who are undergoing medical treatment. The expression of endothelin-1 in heart valve lesions in patients undergoing mitral valve replacement confirms its association with inflammatory activity in rheumatic fever. PMID:24896159

  6. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    PubMed

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  7. Subprosthetic Pannus after Aortic Valve Replacement Surgery: Cardiac CT Findings and Clinical Features.

    PubMed

    Han, Kichang; Yang, Dong Hyun; Shin, So Youn; Kim, Namkug; Kang, Joon-Won; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won; Lim, Tae-Hwan

    2015-09-01

    To investigate the cardiac computed tomographic (CT) findings and clinical implications of subprosthetic pannus in patients who have undergone aortic valve replacement. The institutional review board approved this retrospective study, and the need to obtain written informed consent was waived. From April 2011 to March 2012, 88 patients (mean age, 63 years; 45 men) with a prosthetic aortic valve who underwent cardiac CT were retrospectively selected. Dynamic cardiac CT images were analyzed by using a multiplanar reformatted technique. The presence or absence of subprosthetic pannus and its extent were evaluated at cardiac CT. The geometric orifice area and the effective orifice area of each prosthetic valve were measured to enable analysis of the pannus encroachment ratio in the systolic phase. Hemodynamic parameters at echocardiography, including mean transprosthetic pressure gradient (MTPG), were compared between patients with and those without pannus. The encroachment ratio and the MTPG were correlated by using the Spearman test to evaluate the relationship between the two variables. Seventeen patients (19%) had subprosthetic pannus at cardiac CT. In patients with subprosthetic pannus, MTPG, peak pressure gradient, transvalvular peak velocity, and left ventricular ejection fraction (LVEF) were significantly higher than in patients without pannus (MTPG: 28.1 mm Hg ± 19.8 [standard deviation] vs 14.0 mm Hg ± 6.5, P = .004; peak pressure gradient: 53.1 mm Hg ± 38.4 vs 26.1 mm Hg ± 11.4, P = .004; transvalvular peak velocity: 3.3 m/sec ± 1.3 vs 2.5 m/sec ± 0.5; and LVEF: 64.7% ± 7.4 vs 56.8% ± 10.5, P = .004). A high MTPG (≥40 mm Hg) was observed in four patients at echocardiography, and subprosthetic panni were identified at CT in all four patients. In patients with increased MTPGs, the encroachment ratio by subprosthetic pannus at CT was significantly higher than that in patients with MTPGs of less than 40 mm Hg (42.7 ± 13.3 vs 7.6 ± 3, P = .012

  8. Fast valve

    DOEpatents

    Van Dyke, W.J.

    1992-04-07

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing. 4 figs.

  9. Fast valve

    DOEpatents

    Van Dyke, William J.

    1992-01-01

    A fast valve is disclosed that can close on the order of 7 milliseconds. It is closed by the force of a compressed air spring with the moving parts of the valve designed to be of very light weight and the valve gate being of wedge shaped with O-ring sealed faces to provide sealing contact without metal to metal contact. The combination of the O-ring seal and an air cushion create a soft final movement of the valve closure to prevent the fast air acting valve from having a harsh closing.

  10. Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma.

    PubMed

    Tamcelik, Nevbahar; Ozkok, Ahmet; Sarıcı, Ahmet Murat; Atalay, Eray; Yetik, Huseyin; Gungor, Kivanc

    2013-07-01

    To present and compare the long-term results of Dr. Tamcelik's previously described technique of Tenon advancement and duplication with the conventional Ahmed glaucoma valve (AGV) implantation technique in patients with refractory glaucoma. This study was a multicenter, retrospective case series that included 303 eyes of 276 patients with refractory glaucoma who underwent glaucoma valve implantation surgery. The patients were divided into three groups according to the surgical technique applied and the outcomes compared. In group 1, 96 eyes of 86 patients underwent AGV implant surgery without patch graft; in group 2, 78 eyes of 72 patients underwent AGV implant surgery with donor scleral patch; in group 3, 129 eyes of 118 patients underwent Ahmed valve implant surgery with "combined short scleral tunnel with Tenon advancement and duplication technique". The endpoint assessed was tube exposure through the conjunctiva. In group 1, conjunctival tube exposure was seen in 11 eyes (12.9 %) after a mean 9.2 ± 3.7 years of follow-up. In group 2, conjunctival tube exposure was seen in six eyes (2.2 %) after a mean 8.9 ± 3.3 years of follow-up. In group 3, there was no conjunctival exposure after a mean 7.8 ± 2.8 years of follow-up. The difference between the groups was statistically significant. (P = 0.0001, Chi-square test). This novel surgical technique combining a short scleral tunnel with Tenon advancement and duplication was found to be effective and safe to prevent conjunctival tube exposure after AGV implantation surgery in patients with refractory glaucoma.

  11. Advances in percutaneous interventional therapies: the tricuspid valve.

    PubMed

    Jabbour, Richard J; Giannini, Francesco; Tanaka, Akihito; Mangieri, Antonio; Mikhail, Ghada W; Latib, Azeem; Colombo, Antonio

    2017-05-01

    Tricuspid regurgitation (TR) is a prevalent valve condition, with an estimated 1.6 million people in the USA living with moderate or greater severity. Functional TR, which predominantly develops due to left-sided heart disease, is the predominant condition affecting the tricuspid valve in the Western world and severe TR is associated with substantial morbidity and mortality. In part, due to a prolonged latency period with insidious symptoms, patients are often referred for surgery at advanced stages, with associated increased or prohibitive surgical risk. In addition, surgical treatment can result in high rates of recurrence. Therefore, there is an unmet need for percutaneous therapies that may provide a relatively low-risk treatment option. There are several devices with early human feasibility data available that will be reviewed in this article.

  12. Open heart surgery in Nigeria; a work in progress.

    PubMed

    Falase, Bode; Sanusi, Michael; Majekodunmi, Adetinuwe; Animasahun, Barakat; Ajose, Ifeoluwa; Idowu, Ariyo; Oke, Adewale

    2013-01-12

    There has been limited success in establishing Open Heart Surgery programmes in Nigeria despite the high prevalence of structural heart disease and the large number of Nigerian patients that travel abroad for Open Heart Surgery. The challenges and constraints to the development of Open Heart Surgery in Nigeria need to be identified and overcome. The aim of this study is to review the experience with Open Heart Surgery at the Lagos State University Teaching Hospital and highlight the challenges encountered in developing this programme. This is a retrospective study of patients that underwent Open Heart Surgery in our institution. The source of data was a prospectively maintained database. Extracted data included patient demographics, indication for surgery, euroscore, cardiopulmonary bypass time, cross clamp time, complications and patient outcome. 51 Open Heart Surgery procedures were done between August 2004 and December 2011. There were 21 males and 30 females. Mean age was 29 ± 15.6 years. The mean euroscore was 3.8 ± 2.1. The procedures done were Mitral Valve Replacement in 15 patients (29.4%), Atrial Septal Defect Repair in 14 patients (27.5%), Ventricular Septal Defect Repair in 8 patients (15.7%), Aortic Valve Replacement in 5 patients (9.8%), excision of Left Atrial Myxoma in 2 patients (3.9%), Coronary Artery Bypass Grafting in 2 patients (3.9%), Bidirectional Glenn Shunts in 2 patients (3.9%), Tetralogy of Fallot repair in 2 patients (3.9%) and Mitral Valve Repair in 1 patient (2%). There were 9 mortalities (17.6%) in this series. Challenges encountered included the low volume of cases done, an unstable working environment, limited number of trained staff, difficulty in obtaining laboratory support, limited financial support and difficulty in moving away from the Cardiac Mission Model. The Open Heart Surgery program in our institution is still being developed but the identified challenges need to be overcome if this program is to be sustained. Similar

  13. No effect of a homoeopathic combination of Arnica montana and Bryonia alba on bleeding, inflammation, and ischaemia after aortic valve surgery

    PubMed Central

    Cornu, Catherine; Joseph, Pierre; Gaillard, Ségolène; Bauer, Christian; Vedrinne, Catherine; Bissery, Alvine; Melot, Ghislaine; Bossard, Nadine; Belon, Philippe; Lehot, Jean-Jacques

    2010-01-01

    AIMS Arnica montana is a popular homoeopathic treatment with potential haemostatic and anti-inflammatory properties. A homoeopathic combination of A. montana and Bryonia alba was used in aortic valve surgery to evaluate its effectiveness in reducing bleeding, inflammation, pain and myocardial ischaemia. METHODS One day before surgery, 92 adult patients were randomly assigned to a double-blind parallel trial with either homoeopathic granules or a matching placebo until 4 days after surgery. The primary outcome was the volume of blood/liquid in the drains at their removal. The secondary outcomes included postoperative blood/liquid losses at 12 and 24 h as well as C-reactive protein (CRP), pain, temperature and plasma troponin Ic. RESULTS At 12 h and 24 h after surgery, then at drain removal, blood losses in homoeopathy and placebo groups were not statistically significant (362 ± 218, 520 ± 269 and 640 ± 297 ml vs. 456 ± 440, 620 ± 477 and 796 ± 717 ml; P= 0.19, 0.23 and 0.35, respectively). The statistical modelling did not show significantly different patterns of CRP, troponin and body temperature changes or of pain perception. The number of transfused packed red cells was not significantly different either (P= 0.58). Two patients from each group died during the study period and the number of serious adverse events was not statistically different (six in homoeopathy vs. 10 in placebo groups; Fisher's exact test P= 0.41). CONCLUSIONS In the study setting, there was no evidence of effects of A. montana and B. alba combination on bleeding, inflammation, pain or myocardial ischaemia. PMID:20233176

  14. Combined microwave ablation and minimally invasive open decompression for the management of thoracic metastasis in breast cancer.

    PubMed

    Liu, Bin; Yuan, Zhenchao; Wei, Chang Yuan

    2018-01-01

    The incidence rate of thoracic metastasis from breast cancer is increasing. Microwave ablation is one type of clinical therapy used to treat metastatic spine disease, although it can cause protein denaturation and immediate cell death, and coagulative necrosis can occur. Minimally invasive open decompression is associated with lower rates of surgical complications in comparison to traditional open surgery. Therefore, it is an alternative therapeutic option for spinal metastases. This study aimed to assess the efficacy of microwave ablation with minimally invasive open decompression in the management of breast cancer patients with thoracic metastasis. This single-institution retrospective study investigated 23 cases of thoracic metastasis from breast cancer treated with combined microwave ablation and minimally invasive open decompression. Patients that presented with indications for surgery underwent surgical treatment. Data were collected for pain scores, the Frankel Grade classification system for acute spinal injury, the Karnofsky performance status (KPS) scale and complications due to treatment. Of the 23 patients included in this study, all were successfully treated with microwave ablation and minimal invasive open decompression using our metrics. Of those, 18 patients (78.3%) showed improvement in their KPS results while 5 (21.7%) had alleviation of KPS. All 23 patients showed improvement in their Frankel Grade, suggesting improved neurological function following surgery. Most of the patients reported pain relief. Postoperative complications occurred in 4 patients. Microwave ablation combined with minimally invasive open decompression therapy for breast cancer patients with thoracic metastatic tumors is an alternative treatment that maintains or improves functional outcome in comparison to open surgery.

  15. Long-term outcome in dogs undergoing mitral valve repair with suture annuloplasty and chordae tendinae replacement.

    PubMed

    Mizuno, T; Mizukoshi, T; Uechi, M

    2013-02-01

    Mitral valve repair under cardiopulmonary bypass was performed in three dogs with clinical signs associated with mitral regurgitation that were not controlled by medication. Mitral valve repair comprised circumferential annuloplasty and chordal replacement with expanded polytetrafluoroethylene. One dog died 2 years after surgery because of severe mitral regurgitation resulting from partial circumferential suture detachment. The others survived for over 5 years, but mild mitral valve stenosis persisted in one. The replaced chordae did not rupture in any dog. Mitral valve repair appears to be an effective treatment for mitral regurgitation in dogs. Chordal replacement with expanded polytetrafluoroethylene is a feasible technique, demonstrating long-term durability in dogs. However, mitral annuloplasty techniques need improvement. © 2012 British Small Animal Veterinary Association.

  16. Stemless Ball Valve

    NASA Technical Reports Server (NTRS)

    Burgess, Robert K.; Yakos, David; Walthall, Bryan

    2012-01-01

    This invention utilizes a new method of opening and closing a ball valve. Instead of rotating the ball with a perpendicular stem (as is the case with standard ball valves), the ball is rotated around a fixed axis by two guide pins. This innovation eliminates the leak point that is present in all standard ball valves due to the penetration of an actuation stem through the valve body. The VOST (Venturi Off-Set-Technology) valve has been developed for commercial applications. The standard version of the valve consists of an off-set venturi flow path through the valve. This path is split at the narrowest portion of the venturi, allowing the section upstream from the venturi to be rotated. As this rotation takes place, the venturi becomes restricted as one face rotates with respect to the other, eventually closing off the flow path. A spring-loaded seal made of resilient material is embedded in the upstream face of the valve, making a leak-proof seal between the faces; thus a valve is formed. The spring-loaded lip seal is the only seal that can provide a class six, or bubble-tight, seal against the opposite face of the valve. Tearing action of the seal by high-velocity gas on this early design required relocation of the seal to the downstream face of the valve. In the stemless embodiment of this valve, inner and outer magnetic cartridges are employed to transfer mechanical torque from the outside of the valve to the inside without the use of a stem. This eliminates the leak path caused by the valve stems in standard valves because the stems penetrate through the bodies of these valves.

  17. Broad-Range 16S rDNA PCR on Heart Valves in Infective Endocarditis.

    PubMed

    Müller Premru, Manica; Lejko Zupanc, Tatjana; Klokočovnik, Tomislav; Ruzić Sabljić, Eva; Cerar, Tjaša

    2016-03-01

    Infective endocarditis (IE) is diagnosed by blood and/or resected valve cultivation and echocardiographic findings, as defined by the Duke criteria. Unfortunately, cultures may be negative due to prior antibiotic therapy or fastidious or slow-growing microorganisms. The study aim was to investigate the value of the broad-range polymerase chain reaction (PCR) in addition to blood and valve culture for the detection of causative microorganisms. Between February 2012 and March 2015, valve samples from 36 patients undergoing cardiac surgery were analyzed; of these patients, 26 had a preoperative diagnosis of IE and 10 served as controls. Multiple blood cultures were obtained from 34 patients before antibiotic therapy was commenced. Valve samples were inoculated on bacteriological media and underwent analysis using broad-range PCR (16S rDNA). IE was confirmed microbiologically in 21 of the 26 patients (80.7%); in 20 cases (76.9%) this was by positive blood cultures and in 16 (61.5%) by positive valves. Valves were positive in 15 blood culturepositive patients, and in one blood-culture negative patient. Broad-range PCR detected a microorganism in valves significantly more frequently (n = 14; 53.8%) compared to valve culture (n = 8; 30.7%) (chisquare 11.5, p <0.001). The predominant microorganisms were Staphylococcus aureus, Streptococcus of the viridans group, coagulasenegative staphylococci and Enterococcus faecalis. Blood, valve cultures and broad-range PCR were negative in five patients (19.3%) with IE, and in all 10 subjects of the control group. Broad-range PCR on valves was more sensitive than valve culture. However, blood culture, if taken before the start of antibiotic therapy, was the best method for detecting IE.

  18. Depressurization valve

    DOEpatents

    Skoda, George I.

    1989-01-01

    A depressurization valve for use in relieving completely the pressure in a simplified boiling water reactor is disclosed. The normally closed and sealed valve is provided with a valve body defining a conduit from an outlet of a manifold from the reactor through a valve seat. A closing valve disk is configured for fitting to the valve seat to normally close the valve. The seat below the disk is provided with a radially extending annulus extending a short distance into the aperture defined by the seat. The disk is correspondingly provided with a longitudinally extending annulus that extends downwardly through the aperture defined by the seat towards the high pressure side of the valve body. A ring shaped membrane is endlessly welded to the seat annulus and to the disk annulus. The membrane is conformed over the confronted surface of the seat and disk in a C-sectioned configuration to seal the depressurization valve against the possibility of weeping. The disk is held to the closed position by an elongate stem extending away from the high pressure side of the valve body. The stem has a flange configured integrally to the stem for bias by two springs. The first spring acts from a portion of the housing overlying the disk on the stem flange adjacent the disk. This spring urges the stem and attached disk away from the seat and thus will cause the valve to open at any pressure. A second spring--preferably of the Belleville variety--acts on a latch plate surrounding and freely moving relative to the end of the stem. This second spring overcomes the bias of the first spring and any pressure acting upon the disk. This Belleville spring maintains through its spring force the valve in the closed position. At the same time, the latch plate with its freedom of movement relative to the stem allows the stem to thermally expand during valve temperature excursion. The latch plate in surrounding the stem is limited in its outward movement by a boss attached to the stem at the end of

  19. Modified Ross procedure using a conduit with a synthetic valve.

    PubMed

    Takabayashi, Shin; Kado, Hideaki; Shiokawa, Yuichi; Fukae, Kouji; Nakano, Toshihide

    2004-12-01

    In the Ross procedure, a homograft conduit is commonly used in place of an autotransplanted pulmonary valve. Homograft availability may be a problem and has resulted in a search for alternatives. We performed a modified Ross procedure for right ventricular outflow tract reconstruction with a synthetic valved conduit as an alternative to homograft. Our early results of valvular and right ventricular function were evaluated in patients who used a conduit with a synthetic valve. Subjects consisted of 11 patients, who ranged in age from 5 to 22 years (12.0+/-4.9), and whose body weight ranged from 15.1 to 52.5 (34.3+/-14.4) kg. Indications for surgery were aortic stenosis (n=3), aortic stenosis and regurgitation (n=4), and aortic regurgitation (n=4). Right ventricular outflow tract reconstruction was performed using a hand-fashioned valved conduit prepared by sewing a 0.1 mm thick polytetrafluoroethylene sheet onto the luminal cavity of the 20-28 mm conduit. A conduit made with polytetrafluoroethylene was used in 8 patients, and a Dacron graft was used in 3 patients. There was no in-hospital or late mortality and angiocardiography at discharge revealed that all artificial valves remained active. The mean right atrial pressure and right ventricular end-diastolic pressure were not statistically different from preoperative values. The latest echocardiography (mean interval, 12.6 months) revealed that a mean pressure gradient across the synthetic valve was 11.4+/-11.1 mmHg and none of the patients had moderate or severe regurgitation. We demonstrated that a modified Ross procedure for right ventricular outflow tract reconstruction using a conduit with an appropriate synthetic valve is particularly effective in older children.

  20. a Highly-Integrated Supersonic-Jet Fourier Transform Microwave Spectrometer

    NASA Astrophysics Data System (ADS)

    Gou, Qian; Feng, Gang; Grabow, Jens-Uwe

    2017-06-01

    A highly integrated supersonic-jet Fourier-transform microwave spectrometer of coaxially oriented beam-resonator arrangement (COBRA) type, covering 2-20GHz, has been recently built at Chongqing University, China. Built up almost entirely in an NI PXIe chassis, we take the advantage of the NI PXIe-5451 Dual-channel arbitrary waveform generator and the PXIe-5654 RF signal generator to create a spectrometer with wobbling capacity for fast resonator tuning. Based on the I/Q modulation, associate with PXI control and sequence boards built at the Leibniz Universitat Hannover, the design of the spectrometer is much simpler and very compact. The Fabry-Pérot resonator is semi-confocal with a spherical reflector of 630 mm diameter and a radius of 900 mm curvature and one circulator plate reflector of 630 mm diameter. The vacuum is effectuated by a three-stage mechanical (two-stage rotary vane and roots booster) pump at the fore line of a DN630 ISO-F 20000 L/s oil-diffusion pump. The supersonic-jet expansion is pulsed by a general valve Series 9 solenoid valve which is controlled by a general valve IOTA one driver governed by the experiment-sequence generation. First molecular examples to illustrate the performance of the new setup will include OCS and CF_3CHFCl.

  1. Microwave furnace having microwave compatible dilatometer

    DOEpatents

    Kimrey, Jr., Harold D.; Janney, Mark A.; Ferber, Mattison K.

    1992-01-01

    An apparatus for measuring and monitoring a change in the dimension of a sample being heated by microwave energy is described. The apparatus comprises a microwave heating device for heating a sample by microwave energy, a microwave compatible dilatometer for measuring and monitoring a change in the dimension of the sample being heated by microwave energy without leaking microwaves out of the microwave heating device, and a temperature determination device for measuring and monitoring the temperature of the sample being heated by microwave energy.

  2. Microwave furnace having microwave compatible dilatometer

    DOEpatents

    Kimrey, H.D. Jr.; Janney, M.A.; Ferber, M.K.

    1992-03-24

    An apparatus for measuring and monitoring a change in the dimension of a sample being heated by microwave energy is described. The apparatus comprises a microwave heating device for heating a sample by microwave energy, a microwave compatible dilatometer for measuring and monitoring a change in the dimension of the sample being heated by microwave energy without leaking microwaves out of the microwave heating device, and a temperature determination device for measuring and monitoring the temperature of the sample being heated by microwave energy. 2 figs.

  3. Long-term results of pulmonary valve annular enlargement with valve repair in tetralogy of Fallot.

    PubMed

    Kim, Hyungtae; Sung, Si Chan; Choi, Kwang Ho; Lee, Hyoung Doo; Kim, Geena; Ko, Hoon; Lee, Young Seok

    2018-06-01

    We adopted an operative technique of pulmonary valve (PV) annular enlargement with valve repair in tetralogy of Fallot (TOF) correction to reduce postoperative pulmonary regurgitation (PR) 16 years ago. Here, we have evaluated the long-term results. Between April 2000 and August 2005, 43 patients (26 men) with tetralogy of Fallot with pulmonary stenosis underwent PV annular enlargement with valve repair. The median age and body weight at the time of surgery were 14 months and 10.2 kg, respectively. There was no operative mortality. Mean postoperative PR grade at discharge was 0.93 ± 0.40 (none or trivial in 10 patients, mild in 27 patients, mild to moderate in 5 patients and moderate in 1 patient), and the mean postoperative pressure gradient across PV was 13.0 ± 10.9 mmHg. The mean follow-up duration was 131.9 ± 42.9 months. During follow-up, 1 reoperation was performed for residual ventricular septal defect. The mean PR grade at the last follow-up echocardiography was 1.59 ± 0.60 (mild in 17 patients, mild to moderate in 8 patients, moderate in 14 patients, moderate to severe in 1 patient and severe in 3 patients), and the mean pressure gradient was 22.7 ± 9.9 mmHg. We have compared the incidence of moderate or more PR with the incidence of patients who underwent simple transannular patch enlargement through propensity score matching. The PV repair group had a lower incidence of moderate or more PR compared with the simple transannular patch group (40% vs 68%, P = 0.04). PV annular enlargement with valve repair has reasonable long-term results and yields a lower long-term incidence of significant PR compared with the simple transannular patch enlargement technique.

  4. Determination of oxidation state of iron in normal and pathologically altered human aortic valves

    NASA Astrophysics Data System (ADS)

    Czapla-Masztafiak, J.; Lis, G. J.; Gajda, M.; Jasek, E.; Czubek, U.; Bolechała, F.; Borca, C.; Kwiatek, W. M.

    2015-12-01

    In order to investigate changes in chemical state of iron in normal and pathologically altered human aortic valves X-ray absorption spectroscopy was applied. Since Fe is suspected to play detrimental role in aortic valve stenosis pathogenesis the oxidation state of this element has been determined. The experimental material consisted of 10 μm sections of valves excised during routine surgery and from autopsies. The experiment was performed at the MicroXAS beamline of the SLS synchrotron facility in Villigen (Switzerland). The Fe K-edge XANES spectra obtained from tissue samples were carefully analyzed and compared with the spectra of reference compounds containing iron in various chemical structures. The analysis of absorption edge position and shape of the spectra revealed that both chemical forms of iron are presented in valve tissue but Fe3+ is the predominant form. Small shift of the absorption edge toward higher energy in the spectra from stenotic valve samples indicates higher content of the Fe3+ form in pathological tissue. Such a phenomenon suggests the role of Fenton reaction and reactive oxygen species in the etiology of aortic valve stenosis. The comparison of pre-edge regions of XANES spectra for control and stenotic valve tissue confirmed no differences in local symmetry or spin state of iron in analyzed samples.

  5. Transapical aortic valve implantation without angiography: proof of concept.

    PubMed

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  6. Valve-Sparing Root Replacement Compared With Composite Valve Graft Procedures in Patients With Aortic Root Dilation.

    PubMed

    Ouzounian, Maral; Rao, Vivek; Manlhiot, Cedric; Abraham, Nachum; David, Carolyn; Feindel, Christopher M; David, Tirone E

    2016-10-25

    Although aortic valve-sparing (AVS) operations are established alternatives to composite valve graft (CVG) procedures for patients with aortic root aneurysms, comparative long-term outcomes are lacking. This study sought to compare the results of patients undergoing AVS procedures with those undergoing CVG operations. From 1990 to 2010, a total of 616 patients age <70 years and without aortic stenosis underwent elective aortic root surgery (AVS, n = 253; CVG with a bioprosthesis [bio-CVG], n = 180; CVG with a mechanical prosthesis [m-CVG], n = 183). A propensity score was used as a covariate to adjust for unbalanced variables in group comparisons. Mean age was 46 ± 14 years, 83.3% were male, and mean follow-up was 9.8 ± 5.3 years. Patients undergoing AVS had higher rates of Marfan syndrome and lower rates of bicuspid aortic valve than those undergoing bio-CVG or m-CVG procedures. In-hospital mortality (0.3%) and stroke rate (1.3%) were similar among groups. After adjusting for clinical covariates, both bio-CVG and m-CVG procedures were associated with increased long-term major adverse valve-related events compared with patients undergoing AVS (hazard ratio [HR]: 3.4, p = 0.005; and HR: 5.2, p < 0.001, respectively). They were also associated with increased cardiac mortality (HR: 7.0, p = 0.001; and HR: 6.4, p = 0.003). Furthermore, bio-CVG procedures were associated with increased risk of reoperations (HR: 6.9; p = 0.003), and m-CVG procedures were associated with increased risk of anticoagulant-related hemorrhage (HR: 5.6; p = 0.008) compared with AVS procedures. This comparative study showed that AVS procedures were associated with reduced cardiac mortality and valve-related complications when compared with bio-CVG and m-CVG. AVS is the treatment of choice for young patients with aortic root aneurysm and normal or near-normal aortic cusps. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Excess flow shutoff valve

    DOEpatents

    Kiffer, Micah S.; Tentarelli, Stephen Clyde

    2016-02-09

    Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.

  8. Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma

    PubMed Central

    Shen, Christopher C; Salim, Sarwat; Du, Haiming; Netland, Peter A

    2011-01-01

    Purpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 eyes of 39 patients with underlying diagnosis of neovascular glaucoma, divided into two groups: Ahmed Glaucoma Valve (N = 20) and trabeculectomy with mitomycin C (N = 20). Surgical success was defined as 6 mm Hg ≤ intraocular pressure ≤21 mm Hg, with or without the use of glaucoma medications, with no further glaucoma surgery, and light perception or better vision. Early postoperative hypotony was defined as intraocular pressure <5 mm Hg during the first postoperative week. Results: The average follow-up was 31 months (range 6–87 months) for the Ahmed Glaucoma Valve group and 25 months (6–77 months) for the trabeculectomy group. Although the mean number of postoperative intraocular pressure-lowering medications was significantly higher in the trabeculectomy group compared with the Ahmed Glaucoma Valve group at 3 and 6 month time points, there was no statistically significant difference at any other time point. There was no statistically significant difference between both groups in postoperative visual acuity and intraocular pressure. Success was 70% and 65% at 1 year and 60% and 55% at 2 years after Ahmed Glaucoma Valve and trabeculectomy, respectively. Kaplan–Meier survival curve analysis showed no significant difference in success between the two groups (P = 0.815). Hyphema was the most common complication in both groups. Conclusion: We found similar results after trabeculectomy with mitomycin C and Ahmed Glaucoma Valve implantation in eyes with neovascular glaucoma. PMID:21468334

  9. Successful non-surgical treatment of endocarditis caused by Staphylococcus haemolyticus following transcatheter aortic valve implantation (TAVI).

    PubMed

    Loverix, L; Timmermans, P; Benit, E

    2013-01-01

    We describe a case of a 79-year-old male patient with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) at our institution. He presented at the emergency department with dyspnea and fatigue 7 months after implantation. The diagnosis of early prosthetic valve endocarditis (PVE) caused by Staphylococcus haemolyticus was made by transesophageal echocardiography (TEE) and multiple positive blood cultures. Since our patient was considered inoperable due to a history of coronary artery bypass graft (CABG) surgery with patent bypasses, high peri-operative mortality including renal failure and a poor general prognosis, surgical removal of the valve was not an option. The patient was successfully treated with antibiotic therapy.

  10. The role of visual and direct force feedback in robotics-assisted mitral valve annuloplasty.

    PubMed

    Currie, Maria E; Talasaz, Ali; Rayman, Reiza; Chu, Michael W A; Kiaii, Bob; Peters, Terry; Trejos, Ana Luisa; Patel, Rajni

    2017-09-01

    The objective of this work was to determine the effect of both direct force feedback and visual force feedback on the amount of force applied to mitral valve tissue during ex vivo robotics-assisted mitral valve annuloplasty. A force feedback-enabled master-slave surgical system was developed to provide both visual and direct force feedback during robotics-assisted cardiac surgery. This system measured the amount of force applied by novice and expert surgeons to cardiac tissue during ex vivo mitral valve annuloplasty repair. The addition of visual (2.16 ± 1.67), direct (1.62 ± 0.86), or both visual and direct force feedback (2.15 ± 1.08) resulted in lower mean maximum force applied to mitral valve tissue while suturing compared with no force feedback (3.34 ± 1.93 N; P < 0.05). To achieve better control of interaction forces on cardiac tissue during robotics-assisted mitral valve annuloplasty suturing, force feedback may be required. Copyright © 2016 John Wiley & Sons, Ltd.

  11. [Percutaneously implantable aortic valve: the JenaValve concept evolution].

    PubMed

    Figulla, Hans R; Ferrari, Markus

    2006-10-01

    Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.

  12. Successful simultaneous ipsilateral stenting of common iliac artery stenosis and transfemoral aortic valve replacement.

    PubMed

    Aslan, Abdullah Nabi; Kasapkara, Hacı Ahmet; Sivri, Serkan; Güney, Murat Can; Bozkurt, Engin

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) was designed to treat elderly patients with severe aortic stenosis at high risk for surgery, and is most commonly performed with retrograde approach through femoral arteries. However, in up to 30% of cases, it is either not possible to use this access route or it is considered to have high risk of vascular injury. Alternative approaches have been described for patients with no suitable femoral access: trans-subclavian, transaortic, or direct aortic access; however, since the introduction of new valves deployed with low-profile delivery systems, another alternative transcatheter approach has been discovered. Presently described is experience in 2 cases in which patients were treated with transfemoral TAVR using Edwards SAPIEN 3 transcatheter heart valves immediately following ipsilateral common iliac artery stenting.

  13. Early outcomes of transcatheter aortic valve replacement in patients with severe aortic stenosis: single center experience

    PubMed Central

    Bozkurt, Engin; Keleş, Telat; Durmaz, Tahir; Akçay, Murat; Ayhan, Hüseyin; Bayram, Nihal Akar; Aslan, Abdullah Nabi; Baştuğ, Serdal; Bilen, Emine

    2014-01-01

    Introduction Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. Aim Description early results of our single-center experience with balloon expandable aortic valve implantation. Material and methods Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. Results The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004). Conclusions We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an

  14. Atrioventricular valve repair in patients with functional single-ventricle physiology: impact of ventricular and valve function and morphology on survival and reintervention.

    PubMed

    Honjo, Osami; Atlin, Cori R; Mertens, Luc; Al-Radi, Osman O; Redington, Andrew N; Caldarone, Christopher A; Van Arsdell, Glen S

    2011-08-01

    This study was to determine whether atrioventricular valve repair modifies natural history of single-ventricle patients with atrioventricular valve insufficiency and to identify factors predicting survival and reintervention. Fifty-seven (13.5%) of 422 single-ventricle patients underwent atrioventricular valve repair. Valve morphology, regurgitation mechanism, and ventricular morphology and function were analyzed for effect on survival, transplant, and reintervention with multivariate logistic and Cox regression models. Comparative analysis used case-matched controls. Atrioventricular valve was tricuspid in 67% and common in 28%. Ventricular morphology was right in 83%. Regurgitation mechanisms were prolapse (n = 24, 46%), dysplasia (n = 18, 35%), annular dilatation (n = 8, 15%), and restriction or cleft (n = 2, 4%). Postrepair insufficiency was none or trivial in 14 (26%), mild in 33 (61%), and moderate in 7 (13%). Survival in repair group was lower than in matched controls (78.9% vs 92.7% at 1 year, 68.7% vs 90.6% at 3 years, P = .015). Patients with successful repair and normal ventricular function had equivalent survival to matched controls (P = .36). Independent predictors for death or transplant included increased indexed annular size (P = .05), increased cardiopulmonary bypass time (P = .04), and decreased postrepair ventricular function (P = .01). Ventricular dilation was a time-related factor for all events, including failed repair. Survival was lower in single-ventricle patients operated on for atrioventricular valve insufficiency than in case-matched controls. Patients with little postoperative residual regurgitation and preserved ventricular function had equivalent survival to controls. Lower grade ventricular function and ventricular dilation correlated with death and repair failure, suggesting that timing of intervention may affect outcome. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All

  15. Outcome of bioprosthetic valve replacement in dogs with tricuspid valve dysplasia.

    PubMed

    Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D

    2017-04-01

    To describe the short-term and long-term outcome in dogs with tricuspid valve dysplasia undergoing tricuspid valve replacement under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone tricuspid valve replacement under cardiopulmonary bypass between 2006 and 2012. Dogs were considered candidates for tricuspid valve replacement if they had severe tricuspid valve regurgitation associated with clinical signs of cardiac compromise. Nine dogs of six different breeds were presented. Median age was 13 months (range 7 to 61 months), median weight 26·5 kg (range 9·7 to 59 kg). Eight bovine pericardial valves and one porcine aortic valve were used. One non-fatal intraoperative complication occurred. Complications during hospitalisation occurred in six dogs, four of which were fatal. Of the five dogs discharged, one presented dead due to haemothorax after minor trauma seven days later. The four remaining dogs survived a median of 533 days; all of these dogs received a bovine pericardial valve. Based on our results, tricuspid valve replacement with bovine or porcine prosthetic valves is associated with a high incidence of complications. © 2017 British Small Animal Veterinary Association.

  16. Early Outcomes for Valve-in-valve Transcatheter Aortic Valve Replacement in Degenerative Freestyle Bioprostheses.

    PubMed

    Sang, Stephane Leung Wai; Beute, Tyler; Heiser, John; Berkompas, Duane; Fanning, Justin; Merhi, William

    2017-11-20

    Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  18. Ball valve extractor

    DOEpatents

    Herndon, Charles; Brown, Roger A.

    2002-01-01

    An apparatus and process for removing a ball valve is provided. The ball valve removal tool provides a handle sliding along the length of a shaft. One end of the shaft is secured within an interior cavity of a ball valve while the opposite end of the shaft defines a stop member. By providing a manual sliding force to the handle, the handle impacts the stop member and transmits the force to the ball valve. The direction of the force is along the shaft of the removal tool and disengages the ball valve from the ball valve housing.

  19. Bellows sealed plug valve

    DOEpatents

    Dukas, Jr., Stephen J.

    1990-01-01

    A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.

  20. Check valve installation in pilot operated relief valve prevents reverse pressurization

    NASA Technical Reports Server (NTRS)

    Oswalt, L.

    1966-01-01

    Two check valves prevent reverse flow through pilot-operated relief valves of differential area piston design. Title valves control pressure flow to ensure that the piston dome pressure is always at least as great as the main relief valve discharge pressure.

  1. [Prevention of venous thromboembolism following cardiac, vascular or thoracic surgery].

    PubMed

    Piriou, V; Rossignol, B; Laroche, J-P; Ffrench, P; Lacroix, P; Squara, P; Sirieix, D; D'Attellis, N; Samain, E

    2005-08-01

    In the absence of thromboprophylaxis, coronary artery bypass graft surgery (CABG), intrathoracic surgery (thoracotomy or video-assisted thoracoscopy), abdominal aortic surgery and infrainguinal vascular surgery are high-risk surgeries for the development of venous thromboembolic events (VTE). The incidence of VTE following surgery of the intrathoracic aorta, carotid endarterectomy or mediastinoscopy is unknown. Data from the litterature are lacking to draw evidence-based recommandations for venous thromboprophylaxis after these three types of surgeries, and the following guidelines are but experts'opinions (Grade D recommendations). Thromboprophylaxis is recommended after CABG (Grade D), with either subcutaneous (SC) low molecular weight heparin (LMWH) or SC or intravenous (i.v.) unfractioned heparin (UH) (PTT target = 1.1-1.5 time control value) (both grade D). This may be combined with the use of intermittent pneumatic compression device (Grade B). After valve surgery. The anticoagulation recommended to prevent valve thrombosis is sufficient in order to prevent VTE. We recommend thromboprophylaxis with either LMWH or low dose UH to prevent VTE after aortic or lower limbs infrainguinal vascular surgery (both grade B and D). Vitamine K antagonists (VKA) are not recommended in this indication (Grade D). We recommend thromprophylaxis following intrathoracic surgery via thoracotomy or videoassisted thoracoscopy (grade C). Either subcutaneous LMWH or subcutaneous or i.v. low dose UH may be used (Grade C). Efficacy of intermittent pneumatic compression device has been demonstrated in a study (grade C). VKA are not recommended (grade D). No further recommendation regarding the duration of thromboprophylaxis after these three types of surgeries can be made.

  2. Staphylococcus caprae native mitral valve infective endocarditis.

    PubMed

    Kwok, T'ng Choong; Poyner, Jennifer; Olson, Ewan; Henriksen, Peter; Koch, Oliver

    2016-10-01

    Staphylococcus caprae is a rare cause of infective endocarditis. Here, we report a case involving the native mitral valve in the absence of an implantable cardiac electronic device. A 76-year-old man presented with a 2 week history of confusion and pyrexia. His past medical history included an open reduction and internal fixation of a humeral fracture 17 years previously, which remained non-united despite further revision 4 years later. There was no history of immunocompromise or farm-animal contact. Two sets of blood culture bottles, more than 12 h apart, were positive for S. caprae . Trans-thoracic echocardiography revealed a 1×1.2 cm vegetation on the mitral valve, with moderate mitral regurgitation. Due to ongoing confusion, he had a magnetic resonance imaging brain scan, which showed a subacute small vessel infarct consistent with a thromboembolic source. A humeral SPECT-CT (single-photon emission computerized tomography-computerized tomography) scan showed no clear evidence of acute osteomyelitis. Surgical vegetectomy and mitral-valve repair were considered to reduce the risk of further systemic embolism and progressive valve infection. However, the potential risks of surgery to this patient led to a decision to pursue a cure with antibiotic therapy alone. He remained well 3 months after discharge, with repeat echocardiography demonstrating a reduction in the size of the vegetation (0.9 cm). Management of this infection was challenging due to its rarity and its unclear progression, complicated by the dilemma surrounding surgical intervention in a patient with a complex medical background.

  3. Alternative causes of bioreaction to prosthetic heart valves: three cases with pannus formation.

    PubMed

    Karakoyun, Süleyman; Gürsoy, Ozan Mustafa; Kalçık, Macit; Coban Kökten, Sermin; Ozkan, Mehmet

    2014-01-01

    Pannus formation is an infrequent but serious complication of prosthetic heart valve surgery. The cause of pannus is recognized as a bioreaction to the prostheses; histological investigations have shown that pannus comprises collagen and elastic tissues containing endothelial cells, chronic inflammatory cells, and myofibroblasts. However, the detailed mechanism of its formation has not been fully demonstrated. We aimed to evaluate the potential role of vascular endothelial growth factor (VEGF) and matrix metalloproteinase-2 (MMP-2) in the pathogenesis of pannus formation in three patients with mechanical prosthetic heart valves. Pannus specimens removed from the prostheses were fixed in 10% neutral-buffered formalin for 24 hours after surgical removal and paraffin-embedded using standard procedures. Serial sections were cut at 4 µm for immunohistochemistry analysis. Hematoxylin and eosin (HE) was used in the histological analysis. VEGF and MMP-2 were studied in the immunohistochemistry analysis. Three patients with mechanical prosthetic obstruction due to pannus overgrowth underwent redo valve surgery. In the first and second patients, the mitral prosthesis was explanted along with the pannus overgrowth. The third patient had both aortic and mitral prostheses; the aortic prosthesis was explanted with obstructive pannus formation, whereas the mitral valve was spared with excision of the nonobstructive pannus. The immunohistochemical study demonstrated the expressions of MMP-2 and VEGF in all of the pannus specimens acquired from these cases. VEGF and MMP-2 may play a role in the mechanism of pannus formation as the elements of the chronic active inflammatory process.

  4. Bioprosthetic mitral valve replacement in patients aged 65 years or younger: long-term outcomes with the Carpentier-Edwards PERIMOUNT pericardial valve.

    PubMed

    Bourguignon, Thierry; Espitalier, Fabien; Pantaleon, Clémence; Vermes, Emmanuelle; El-Arid, Jean Marc; Loardi, Claudia; Karam, Elias; Candolfi, Pascal; Ivanes, Fabrice; Aupart, Michel

    2018-02-12

    Mitral valve replacement using a bioprosthesis remains controversial in young patients because data on long-term outcomes are missing. This study evaluated the long-term results of the PERIMOUNT pericardial mitral bioprosthesis in patients aged 65 years or younger. From 1984 to 2010, 148 Carpentier-Edwards PERIMOUNT mitral bioprostheses were implanted in 148 patients aged 65 years or younger. Baseline clinical, perioperative and follow-up data were recorded prospectively. Structural valve deterioration (SVD) was defined by strict echocardiographic assessment. The mean follow-up period was 8.6 ± 5.5 years, for a total of 1269 valve-years. Operative mortality rate was 2.0%. Fifty-one late deaths occurred (linearized rate 4.0% per valve-year). Actuarial survival rates averaged 70 ± 4%, 53 ± 6% and 31 ± 7% after 10, 15 and 20 years of follow-up, respectively. Actuarial freedom from SVD at 10, 15 and 20 years was 78 ± 5%, 47 ± 7% and 19 ± 7%, respectively. Reoperation was associated with no operative mortality. Actuarial freedom from reoperation due to SVD at 10, 15 and 20 years was 82 ± 4%, 50 ± 6% and 25 ± 8%, respectively. Competing risk analysis demonstrated an actual risk of explantation secondary to SVD at 20 years of 44 ± 5%. Expected valve durability was 14.2 years for this age group. In the selected patients aged 65 years or younger undergoing mitral valve replacement with a pericardial bioprosthesis, the expected valve durability was 14.2 years. Reoperation for SVD was associated with a low risk of mortality. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Optimal Elastomeric Scaffold Leaflet Shape for Pulmonary Heart Valve Leaflet Replacement

    PubMed Central

    Fan, Rong; Bayoumi, Ahmed S.; Chen, Peter; Hobson, Christopher M.; Wagner, William R.; Mayer, John E.; Sacks, Michael S.

    2012-01-01

    Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery. PMID:23294966

  6. Trans-apical aortic valve implantation in patients with severe calcification of the ascending aorta.

    PubMed

    Buz, Semih; Pasic, Miralem; Unbehaun, Axel; Drews, Thorsten; Dreysse, Stephan; Kukucka, Marian; Mladenow, Alexander; Hetzer, Roland

    2011-08-01

    In patients with calcification of the ascending aorta, postoperative stroke and mortality rates remain high after conventional aortic valve replacement, but the results of trans-apical aortic valve implantation in these patients are not known. We evaluate the outcome of trans-apical aortic valve implantation in patients with severely calcified ascending aorta in a single center with expanded procedural experience. Between April 2008 and July 2010, 258 patients underwent trans-apical aortic valve implantation using Edwards Sapien valve. By computed tomography (CT) scan, we identified 46 (18%) patients with severe calcification of the ascending aorta (16 with porcelain aorta and 30 with severe, but not complete, calcification). Of 46 patients (mean age 77 ± 10 years, range 63-90 years; EuroSCORE (European System for Cardiac Operative Risk Evaluation) 45 ± 22%; STS (Society of Thoracic Surgeons) score 23 ± 13) with calcified aorta, 15 received 23-mm valves and 31 patients 26-mm valves. Primary valve implantation was successful in 44 patients and a second valve was implanted (valve-in-valve) in two. Six patients underwent concomitant interventions (three elective percutaneous coronary intervention (PCI), one off-pump coronary artery bypass (OPCAB), one tricuspid valve reconstruction, and one left-ventricular (LV) aneurysmectomy). The final procedural results showed valve incompetence (trace or grade 1) in 17 (37%) patients and paravalvular leak in 15 (32.6%) (trace in 10 and grade 1 in five). There was no 30-day mortality. Postoperatively, cranial CT showed new cerebral ischemia areas in three patients (6.2%), but only one patient (2.1%) experienced postoperative neurological deficit (temporary aphasia). Survival at 6 and 12 months was 88% and 85.2%, respectively. Trans-apical aortic valve implantation can be performed safely in patients with aortic valve stenosis and severe calcification of the ascending aorta. Copyright © 2010 European Association for Cardio

  7. Prosthetic valve endocarditis: early and late outcome following medical or surgical treatment

    PubMed Central

    Akowuah, E F; Davies, W; Oliver, S; Stephens, J; Riaz, I; Zadik, P; Cooper, G

    2003-01-01

    Objective: To compare the early and late outcome of medical and surgical treatment in patients with prosthetic valve endocarditis within a single unit. Design: All patients with proven prosthetic valve endocarditis treated in one institution between 1989 and 1999 were studied. Results: There were 66 patients (24 female, 42 male), mean (SD) age 57 (14) years. Of these, 28 were treated with antibiotics alone and 38 with a combination of antibiotics and surgery. The in-hospital mortality for the antibiotic group was 46% and for the surgical group, 24%. However, seven patients in the antibiotic group were considered too sick for curative treatment. The mortality in the remaining 21 medically treated patients (6/21; 29%) was not significantly different from that in the surgically treated patients (p = 0.15). Six patients in the medically treated group and one in the surgically treated group required late reoperation. Endocarditis recurred in three patients in the medically treated group, two of whom were treated surgically, and in one patient in the surgically treated group. Kaplan–Meier survival at 10 years was 28% in the medically treated group v 58% in the surgically treated group (p = 0.04). Freedom from endocarditis at five years was 60% in the surgically treated group and 65% in the medically treated group. Conclusions: Prosthetic valve endocarditis is a serious condition with high early and late mortality, irrespective of the treatment employed. These data show that selected patients with prosthetic valve endocarditis can be successfully treated with antibiotics alone. If required, surgery in this difficult group of patients can provide satisfactory freedom from recurrent infection. PMID:12591827

  8. Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas

    PubMed Central

    Abulon, Dina Joy; Charles, Martin; Charles, Daniel E

    2015-01-01

    Purpose To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP), fluid leakage, and vitreous incarceration during simulated vitrectomy. Methods Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes. Results In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005), and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05) and 27-gauge (P<0.05) non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas. Conclusion Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy. PMID:26445520

  9. Twenty-five-year experience with the Björk-Shiley convexoconcave heart valve: a continuing clinical concern.

    PubMed

    Blot, William J; Ibrahim, Michel A; Ivey, Tom D; Acheson, Donald E; Brookmeyer, Ron; Weyman, Arthur; Defauw, Joseph; Smith, J Kermit; Harrison, Donald

    2005-05-31

    The first Björk-Shiley convexoconcave (BSCC) prosthetic heart valves were implanted in 1978. The 25th anniversary provided a stimulus to summarize the research data relevant to BSCC valve fracture, patient management, and current clinical options. Published and unpublished data on the risks of BSCC valve fracture and replacement were compiled, and strategies for identifying candidates for prophylactic valve reoperation were summarized. By December 2003, outlet strut fractures (OSFs), often with fatal outcomes, had been reported in 633 BSCC valves (0.7% of 86,000 valves implanted). Fractures still continue to occur, but average rates of OSFs in 60 degrees valves are now <0.1% per year. OSF risk varies markedly by valve characteristics, especially valve angle and size, with weaker effects associated with other manufacturing variables. OSF risks are mildly lower among women than men but decline sharply with advancing age. The risks of valve replacement typically greatly exceed those of OSF. By comparing individualized estimated risks of OSF versus valve replacement, guidelines have been developed to identify the small percentage of BSCC patients (mostly younger men) who would be expected to have a gain in life expectancy should reoperative surgery be performed. Twenty-five years after the initial BSCC valve implants, fractures continue to occur. Continued monitoring of BSCC patients is needed to track and quantify risks and enable periodic updating of guidelines for patients and their physicians.

  10. Mycobacterium chimaera Infection After Aortic Valve Replacement Presenting With Aortic Dissection and Pseudoaneurysm.

    PubMed

    O'Neil, C R; Taylor, G; Smith, S; Joffe, A M; Antonation, K; Shafran, S; Kunimoto, D

    2018-02-01

    We present a case of Mycobacterium chimaera infection presenting with aortic dissection and pseudoaneuysm in a 22-year-old man with a past history of aortic valve replacement. Clinicians should consider M. chimaera infection in those presenting with aortic dissection as a late complication of cardiovascular surgery.

  11. Microfluidic sieve valves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  12. Increased dietary intake of vitamin A promotes aortic valve calcification in vivo

    PubMed Central

    Huk, Danielle J.; Hammond, Harriet L.; Kegechika, Hiroyuki; Lincoln, Joy

    2013-01-01

    Objective Calcific aortic valve disease (CAVD) is a major public health problem with no effective treatment available other than surgery. We previously showed that mature heart valves calcify in response to retinoic acid (RA) treatment through downregulation of the SRY-transcription factor Sox9. In this study, we investigated the effects of excess vitamin A and its metabolite RA on heart valve structure and function in vivo, and examined the molecular mechanisms of RA signaling during the calcification process in vitro. Methods and Results Using a combination of approaches, we defined CAVD pathogenesis in mice fed 200 IU/g and 20 IU/g of retinyl palmitate for 12 months at molecular, cellular and functional levels. We show that mice fed excess vitamin A develop aortic valve stenosis and leaflet calcification associated with increased expression of osteogenic genes and decreased expression of cartilaginous markers. Using a pharmacological approach, we show that RA-mediated Sox9 repression and calcification is regulated by classical RA signaling and requires both RAR and RXR receptors. Conclusions Our studies demonstrate that excess vitamin A dietary intake promotes heart valve calcification in vivo. Therefore suggesting that hypervitaminosis A could serve as a new risk factor of CAVD in the human population. PMID:23202364

  13. Traumatic rupture of the tricuspid valve and multi-modality imaging

    PubMed Central

    Corneli, Mariana; Conde, Diego; Ronderos, Ricardo

    2014-01-01

    Introduction Motor vehicle accident (MVA) account for most cases of traumatic rupture of the tricuspid valve. Valve rupture during an MVA is generated by an abrupt deceleration coupled with an increase in right-side cardiac pressures (Valsalva maneuver and thorax compression). Case A 39-year-old asymptomatic man was referred for an echocardiogram due to the presence of a systolic murmur. He had no prior significant medical history, except for a remote MVA 3 years ago. Real-time 3D echocardiography (RT3DE) showed a tear in the body of the anterior leaflet and not at the cord, as was suggested by two-dimensional transthoracic echocardiography (2D-TTE). Based on these findings, the mechanism was considered anterior leaflet rupture of the tricuspid valve, secondary to chest blunt trauma. The anterior leaflet was repaired using two polytetrafluoroethylene sutures, and tricuspid annuloplasty with an Edwards ring was performed. Conclusions Multimodality imaging helps to determine timing of surgery in asymptomatic traumatic tricuspid rupture. The combination of echocardiography and magnetic resonance imaging provide information of volumetric data and contractility of the right ventricle (RV) during follow-up. RT3DE gives information relevant to the morphological and functional characterization of the valve, allowing the planning of appropriate surgical procedure. PMID:25414827

  14. Problem: Heart Valve Stenosis

    MedlinePlus

    ... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...

  15. Transaortic edge-to-edge mitral valve repair for moderate secondary/functional mitral regurgitation in patients undergoing aortic root/valve intervention.

    PubMed

    Choudhary, Shiv Kumar; Abraham, Atul; Bhoje, Amol; Gharde, Parag; Sahu, Manoj; Talwar, Sachin; Airan, Balram

    2017-11-01

    The present study evaluates the feasibility, safety, and efficacy of edge-to-edge repair for moderate secondary/functional mitral regurgitation in patients undergoing aortic valve/root interventions. Sixteen patients underwent transaortic edge-to-edge mitral valve repair. Mitral regurgitation was 2+ in 8 patients and 3+ in 6 patients. Two patients in whom cardiac arrest developed preoperatively had severe (4+) mitral regurgitation. Patients underwent operation for severe aortic regurgitation ± aortic root lesions. The mean left ventricular systolic and diastolic diameters were 51.5 ± 12.8 mm and 70.7 ± 10.7 mm, respectively. Left ventricular ejection fraction ranged from 20% to 60%. Primary surgical procedure included Bentall's ± hemiarch replacement in 10 patients, aortic valve replacement in 5 patients, and noncoronary sinus replacement with aortic valve repair in 1 patient. Severity of mitral regurgitation decreased to trivial or zero in 13 patients, 1+ in 2 patients, and 2+ in 1 patient. There were no gradients across the mitral valve in 9 patients, less than 5 mm Hg in 6 patients, and 9 mm Hg in 1 patient. There was no operative mortality. Follow-up ranged from 2 weeks to 54 months. Echocardiography showed trivial or no mitral regurgitation in 12 patients, 1+ in 2 patients, and 2+ in 2 patients. None of the patients had significant mitral stenosis. The mean left ventricular systolic and diastolic diameters decreased to 40.5 ± 10.3 mm and 58.7 ± 11.6 mm, respectively. Ejection fraction also improved slightly (22%-65%). Transaortic edge-to-edge mitral valve repair is a safe and effective technique to abolish secondary/functional mitral regurgitation. However, its impact on overall survival needs to be studied. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  16. Time to achieving therapeutic international normalized ratio increases hospital length of stay after heart valve replacement surgery.

    PubMed

    Arendt, Christopher J; Hong, Joon Hwa; Daly, Richard C; Scott, Christopher; Mehta, Ramila A; Bailey, Kent; Pathak, Jyotishman; Pereira, Naveen L

    2017-05-01

    Achieving a therapeutic international normalized ratio (INR) before hospital discharge is an important inpatient goal for patients undergoing mechanical cardiac valve replacement (MCVR). The use of clinical algorithms has reduced the time to achieve therapeutic INR (TTI) with warfarin therapy. Whether TTI prolongs length of stay (LOS) is unknown. Patients who underwent MCVR over a consecutive 42-month period were included. Clinical data were obtained from the Society of Thoracic Surgeons Adult Cardiac Surgery database and electronic medical records. Therapeutic INR was defined as per standard guidelines. Warfarin dose was prescribed using an inpatient pharmacy-managed algorithm and computer-based dosing tool. International normalized ratio trajectory, procedural needs, and drug interactions were included in warfarin dose determination. There were 708 patients who underwent MCVR, of which 159 were excluded for reasons that would preclude or interrupt warfarin use. Among the remainder of 549 patients, the average LOS was 6.4days and mean TTI was 3.5days. Landmark analysis showed that subjects in hospital on day 4 (n=542) who achieved therapeutic INR were more likely to be discharged by day 6 compared with those who did not achieve therapeutic INR (75% vs 59%, P<.001). Multivariable proportional hazards regression with TTI as a time-dependent effect showed a strong association with discharge (P=.0096, hazard ratio1.3) after adjustment for other significant clinical covariates. Time to achieve therapeutic INR is an independent predictor of LOS in patients requiring anticoagulation with warfarin after MCVR surgery. Alternative dosing and anticoagulation strategies will need to be adopted to reduce LOS in these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Evaluation of tricuspid valve regurgitation following laser lead extraction†.

    PubMed

    Pecha, Simon; Castro, Liesa; Gosau, Nils; Linder, Matthias; Vogler, Julia; Willems, Stephan; Reichenspurner, Hermann; Hakmi, Samer

    2017-06-01

    The objective of this study was to examine the effect of laser lead extraction (LLE) on the development of post-procedural tricuspid regurgitation (TR). Some reports have suggested an increase in TR associated with LLE. We present a series of patients who underwent both, LLE and complete echocardiographic evaluation for TR. A single centre analysis of consecutive patients referred for LLE between January 2012 and August 2015. One hundred and three patients had tricuspid valve function evaluated before the procedure with a transthoracic echocardiography (TTE), during the procedure using transoesophageal echocardiography and postoperatively using a TTE. TR was graded from 0 (none) to 4 (severe). We treated 235 leads in 103 patients, including 118 ventricular leads. Seventy-seven were male (74.8%) and 26 female (25.2%), with a mean age of 65.6 ± 15.4 years. Mean time from initial lead implantation was 98.0 ± 67.3 months. Twenty-one patients (20.4%) had ejection fraction below 30%. No intra-procedural worsening of tricuspid valve function was seen with TEE in any of the patients. Ten patients (9.7%) were found to have TR before LLE that returned to normal valve function after the procedure. Two patients (1.9%) experienced mild TR after the procedure (both with tricuspid valve endocarditis). Ninety-one patients (88.3%) did not experience any significant change of the tricuspid valve function after LLE. Transthoracic and transoesophageal echocardiography findings showed that laser lead extraction was not associated with a significant increase in the incidence of tricuspid valve regurgitation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Fibrous composite material for textile heart valve design: in vitro assessment.

    PubMed

    Amri, Amna; Laroche, Gaetan; Chakfe, Nabil; Heim, Frederic

    2018-04-17

    With over 150,000 implantations performed over the world, transcatheter aortic valve replacement (TAVR) has become a surgical technique, which largely competes with open surgery valve replacement for an increasing number of patients. The success of the procedure favors the research toward synthetic valve leaflet materials as an alternative to biological tissues, whose durability remains unknown. In particular, fibrous constructions have recently proven to be durable in vivo over a 6-month period of time in animal sheep models. Exaggerated fibrotic tissue formation remains, however, a critical issue to be addressed. This work investigates the design of a composite fibrous construction combining a woven polyethylene terephthalate (PET) layer and a non-woven PET mat, which are expected to provide, respectively, strength and appropriate topography toward limited fibrotic tissue ingrowth. For this purpose, a specific equipment has been developed to produce non-woven PET mats made from fibers with small diameter. These mats were assembled with woven PET substrates using various assembling techniques in order to obtain hybrid fibrous constructions. The physical and mechanical properties of the obtained materials were assessed and valve samples were manufactured to be tested in vitro for hydrodynamic performances. The results show that the composite fibrous construction is characterized by properties suitable for the valve leaflet function, but the durability of the assembling is however limited under accelerated cyclic loading.

  19. Vacuum breaker valve assembly

    DOEpatents

    Thompson, J.L.; Upton, H.A.

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening. 1 fig.

  20. Vacuum breaker valve assembly

    DOEpatents

    Thompson, Jeffrey L.; Upton, Hubert Allen

    1999-04-27

    Breaker valve assemblies for a simplified boiling water nuclear reactor are described. The breaker valve assembly, in one form, includes a valve body and a breaker valve. The valve body includes an interior chamber, and an inlet passage extends from the chamber and through an inlet opening to facilitate transporting particles from outside of the valve body to the interior chamber. The breaker valve is positioned in the chamber and is configured to substantially seal the inlet opening. Particularly, the breaker valve includes a disk which is sized to cover the inlet opening. The disk is movably coupled to the valve body and is configured to move substantially concentrically with respect to the valve opening between a first position, where the disk completely covers the inlet opening, and a second position, where the disk does not completely cover the inlet opening.

  1. Zero-leak valve

    NASA Technical Reports Server (NTRS)

    Macglashan, W. F., Jr.

    1980-01-01

    Zero-leakage valve has fluid-sealing diaphragm support and flat sievelike sealing surface. Diaphragm-support valve is easy to fabricate and requires minimum maintenance. Potential applications include isolation valve for waste systems and remote air-actuated valve. Device is also useful in controlling flow of liquid fluorine and corrosive fluids at high pressures.

  2. Incidence and etiological mechanism of stroke in cardiac surgery.

    PubMed

    Arribas, J M; Garcia, E; Jara, R; Gutierrez, F; Albert, L; Bixquert, D; García-Puente, J; Albacete, C; Canovas, S; Morales, A

    2017-12-14

    We studied patients who had experienced a stroke in the postoperative period of cardiac surgery, aiming to analyse their progression and determine the factors that may influence prognosis and treatment. We established a protocol for early detection of stroke after cardiac surgery and collected data on stroke onset and a number of clinical, surgical, and prognostic variables in order to perform a descriptive analysis. Over the 15-month study period we recorded 16 strokes, which represent 2.5% of the patients who underwent cardiac surgery. Mean age in our sample was 69 ± 8 years; 63% of patients were men. The incidence of stroke in patients aged 80 and older was 5.1%. Five patients (31%) underwent emergency surgery. By type of cardiac surgery, 7% of patients underwent mitral valve surgery, 6.5% combined surgery, 3% aortic valve surgery, and 2.24% coronary surgery. Most cases of stroke (44%) were due to embolism, followed by hypoperfusion (25%). Stroke occurred within 2 days of surgery in 69% of cases. The mean NIHSS score in our sample of stroke patients was 9; code stroke was activated in 10 cases (62%); one patient (14%) underwent thrombectomy. Most patients progressed favourably: 13 (80%) scored≤2 on the modified Rankin Scale at 3 months. None of the patients died during the postoperative hospital stay. In our setting, strokes occurring after cardiac surgery are usually small and have a good long-term prognosis. Most of them occur within 2 days, and they are mostly embolic in origin. The incidence of stroke in patients aged 80 and older and undergoing cardiac surgery is twice as high as that of the general population. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Percutaneous pulmonary valve implantation: an update.

    PubMed

    Lurz, Philipp; Bonhoeffer, Philipp; Taylor, Andrew M

    2009-07-01

    The field of percutaneous valvular interventions is one of the most exciting and rapidly developing within interventional cardiology. Percutaneous pulmonary valve implantation (PPVI) represents the first in-human application of these techniques and is a nonsurgical option for treating right ventricular outflow tract/pulmonary trunk dysfunction. With the growing numbers of patients with right ventricle to pulmonary artery conduit dysfunction after repair of congenital heart disease, the importance of a technique with lower morbidity and mortality, good patient acceptance and efficacy, that is comparable to surgery, cannot be underestimated. Over the last 9 years, PPVI has become a feasible, safe and effective treatment for both conduit stenosis and regurgitation. Median follow-up data show good freedom from reoperation and recatheterization and demonstrate that PPVI can postpone open-heart surgery, thereby potentially reducing the number of operations that patients have to undergo within their lifetime. Complications seen after PPVI, in particular stent fractures, can require reintervention in some cases (second stent-in-stent PPVI); however, valve competency remains good, with significant regurgitation during follow-up only seen in the context of occasional endocarditis. Attempts are now being made to prolong the lifespan of the device by reducing the incidence of stent fractures. Further, meticulous patient selection must be maintained to ensure that hemodynamic results are optimized and the safety of the procedure remains high. Finally, new devices have to be developed that will allow for PPVI in dilated, distensible outflow tracts, to offer this nonsurgical treatment option to a larger patient population with congenital heart disease.

  4. Percutaneous Implantation of the self-expanding valve Prosthesis a patient with homozygous familial hypercholesterolemia severe aortic stenosis and porcelain aorta.

    PubMed

    Sahiner, Levent; Asil, Serkan; Kaya, Ergün Baris; Ozer, Necla; Aytemir, Kudret

    2016-10-01

    Transcatheter aortic valve implantation (TAVI) has shown favorable outcomes in patients with severe symptomatic aortic valve stenosis who are at high surgical risk or inappropriate for open heart surgery. However, concerns exist over treating patients who have porcelain aorta and familial hypercholesterolemia, due to the potential complications of aortic root and aortic annulus. In this case report, we present a patient with familial hypercholesterolemia, symptomatic severe aortic stenosis, previous coronary artery bypass grafting and porcelain aorta, who was successfully treated with TAVI using a CoreValve. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  6. Scissor thrust valve actuator

    DOEpatents

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  7. Outcomes of Aortic Valve-Sparing Operations in Marfan Syndrome.

    PubMed

    David, Tirone E; David, Carolyn M; Manlhiot, Cedric; Colman, Jack; Crean, Andrew M; Bradley, Timothy

    2015-09-29

    In many cardiac units, aortic valve-sparing operations have become the preferred surgical procedure to treat aortic root aneurysm in patients with Marfan syndrome, based on relatively short-term outcomes. This study examined the long-term outcomes of aortic valve-sparing operations in patients with Marfan syndrome. All patients with Marfan syndrome operated on for aortic root aneurysm from 1988 through 2012 were followed prospectively for a median of 10 years. Follow-up was 100% complete. Time-to-event analyses were calculated using the Kaplan-Meier method with log-rank test for comparisons. A total of 146 patients with Marfan syndrome had aortic valve-sparing operations. Reimplantation of the aortic valve was performed in 121 and remodeling of the aortic root was performed in 25 patients. Mean age was 35.7 ± 11.4 years and two-thirds were men. Nine patients had acute, 2 had chronic type A, and 3 had chronic type B aortic dissections before surgery. There were 1 operative and 6 late deaths, 5 caused by complications of dissections. Mortality rate at 15 years was 6.8 ± 2.9%, higher than the general population matched for age and sex. Five patients required reoperation on the aortic valve: 2 for endocarditis and 3 for aortic insufficiency. Three patients developed severe, 4 moderate, and 3 mild-to-moderate aortic insufficiency. Rate of aortic insufficiency at 15 years was 7.9 ± 3.3%, lower after reimplantation than remodeling. Nine patients developed new distal aortic dissections during follow-up. Rate of dissection at 15 years was 16.5 ± 3.4%. Aortic valve-sparing operations in patients with Marfan syndrome were associated with low rates of valve-related complications in long-term follow-up. Residual and new aortic dissections were the leading cause of death. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. 'Caput medusae': tension reduction on a dehiscent native annulus in valve implantation in an endocarditis case.

    PubMed

    Albes, Johannes M

    2017-12-01

    Interrupted pledget-armed braided sutures are widely used for valve implantation. In a 74-year-old woman with aortic valve endocarditis and shallow annular abscess, annulus dehiscence resulted after resection. As resistance was too high for sufficient primary approximation, a snug fit of the valve by means of circumferential application of curbed tourniquets resembling Medusa's head after suture placement was achieved. Closest possible approximation of the upper and lower part of the annulus with the prosthesis prior to final fixation was thus possible, so that application of too much tension on a single suture could be avoided. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve

    PubMed Central

    VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L

    2017-01-01

    The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780

  10. Cardiovascular magnetic resonance in adults with previous cardiovascular surgery.

    PubMed

    von Knobelsdorff-Brenkenhoff, Florian; Trauzeddel, Ralf Felix; Schulz-Menger, Jeanette

    2014-03-01

    Cardiovascular magnetic resonance (CMR) is a versatile non-invasive imaging modality that serves a broad spectrum of indications in clinical cardiology and has proven evidence. Most of the numerous applications are appropriate in patients with previous cardiovascular surgery in the same manner as in non-surgical subjects. However, some specifics have to be considered. This review article is intended to provide information about the application of CMR in adults with previous cardiovascular surgery. In particular, the two main scenarios, i.e. following coronary artery bypass surgery and following heart valve surgery, are highlighted. Furthermore, several pictorial descriptions of other potential indications for CMR after cardiovascular surgery are given.

  11. A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications.

    PubMed

    Rosa, Benoit; Machaidze, Zurab; Shin, Borami; Manjila, Sunil; Brown, David W; Baird, Christopher W; Mayer, John E; Dupont, Pierre E

    2017-11-01

    This paper provides detailed instructions for constructing low-cost bioprosthetic semilunar valves for animal research and clinical training. This work fills an important gap between existing simulator training valves and clinical valves by providing fully functioning designs that can be employed in ex vivo and in vivo experiments and can also be modified to model valvular disease. Valves are constructed in 4 steps consisting of creating a metal frame, covering it with fabric and attaching a suture ring and leaflets. Computer-aided design files are provided for making the frame from wire or by metal 3D printing. The covering fabric and suturing ring are made from materials readily available in a surgical lab, while the leaflets are made from pericardium. The entire fabrication process is described in figures and in a video. To demonstrate disease modelling, design modifications are described for producing paravalvular leaks, and these valves were evaluated in porcine ex vivo (n = 3) and in vivo (n = 6) experiments. Porcine ex vivo and acute in vivo experiments demonstrate that the valves can replicate the performance of clinical valves for research and training purposes. Surgical implantation is similar, and echocardiograms are comparable to clinical valves. Furthermore, valve leaflet function was satisfactory during acute in vivo tests with little central regurgitation, while the paravalvular leak modifications consistently produced leaks in the desired locations. The detailed design procedure presented here, which includes a tutorial video and computer-aided design files, should be of substantial benefit to researchers developing valve disease models and to clinicians developing realistic valve training systems. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    PubMed

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at <26 years after implantation. Localized disk wear was found at the sites where the disk abutted the struts of the cage, in disk valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  13. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis.

    PubMed

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-09-21

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. 2015 BMJ Publishing Group Ltd.

  14. Prosthetic mitral valve obstruction: role of real-time three-dimensional transesophageal echocardiography in diagnosis

    PubMed Central

    Kannan, Arun; Jahan, Kahroba; Lotun, Kapildeo; Janardhanan, Rajesh

    2015-01-01

    Acute prosthetic valve thrombosis is a potentially serious complication with an incidence as high as 6% per patient-year for prostheses in the mitral position. Accurate diagnosis of the degree of obstruction and differentiation of pannus versus thrombus is critical in determination of the best mode of therapy. We discuss a case of a patient with multiple comorbidities who presented with mechanical mitral valve obstruction where both transthoracic and two-dimensional transesophageal echocardiography (TEE) were limited in making an accurate diagnosis regarding the mechanism of obstruction. Real-time 3D-TEE (RT-3DTEE) was critical in identifying a partial thrombus on the mechanical valve and guided the choice of thrombolysis as the most appropriate intervention, thus avoiding high-risk surgery in this patient with significant multiple comorbidities. PMID:26392458

  15. Effect of chronic mitral valve damage on activity of pulmonary rapidly adapting receptors in the rabbit

    PubMed Central

    Gunawardena, S; Bravo, E; Kappagoda, C T

    1998-01-01

    The effects of acute pulmonary venous congestion on the activity of rapidly adapting receptors (RARs) were determined in intact (control and sham-operated) rabbits and in rabbits 6 and 12 weeks after surgical destruction of the mitral valve.Destruction of the mitral valve increased the mean left atrial pressure (LAP) by approximately 2·6 and 3·8 mmHg, 6 and 12 weeks after surgery, respectively. These changes were accompanied by significant increases in left ventricular weight. The effect of acute increments in LAP on RAR activity was examined against this background of chronic pulmonary venous congestion.In intact control and sham-operated animals RAR activity increased from 48·8 ± 0·9 to 83·5 ± 3·6 and 121·1 ± 4·7 action potentials min−1 when the LAP was raised by 5 and 10 mmHg, respectively, above control values. Six weeks after surgery only 40 % of RARs were activated in this way.In animals maintained for 12 weeks after surgery, RAR activity at LAPs of 6·6 ± 1·2 (control), 11·6 ± 1·2 and 16·6 ± 1·2 (mmHg) were 35·5 ± 2·3, 33·8 ± 14·4 and 34·0 ± 3·4 action potentials min−1, respectively. These changes were statistically not significant.Slowly adapting receptors (SARs) in the lung showed a small but statistically significant increase in activity when the left atrial pressure was acutely elevated in both intact and mitral valve damaged animals.It is concluded that chronic pulmonary venous congestion resulting from destruction of the mitral valve attenuates the ability of RARs to respond to acute moderate elevations of LAP. PMID:9679165

  16. Coronary risk stratification of patients undergoing surgery for valvular heart disease.

    PubMed

    Hasselbalch, Rasmus Bo; Engstrøm, Thomas; Pries-Heje, Mia; Heitmann, Merete; Pedersen, Frants; Schou, Morten; Mickley, Hans; Elming, Hanne; Steffensen, Rolf; Køber, Lars; Iversen, Kasper

    2017-01-15

    Multislice computed tomography (MSCT) is a non-invasive, less expensive, low-radiation alternative to coronary angiography (CAG) prior to valvular heart surgery. MSCT has a high negative predictive value for coronary artery disease (CAD) but previous studies of patients with valvular disease have shown that MSCT, as the primary evaluation technique, lead to re-evaluation with CAG in about a third of cases and it is therefore not recommended. If a subgroup of patients with low- to intermediate risk of CAD could be identified and examined with MSCT, it could be cost-effective, reduce radiation and the risk of complications associated with CAG. The study cohort was derived from a national registry of patients undergoing CAG prior to valvular heart surgery. Using logistic regression, we identified significant risk factors for CAD and developed a risk score (CT-valve score). The score was validated on a similar cohort of patients from another registry. The study cohort consisted of 2221 patients, 521 (23.5%) had CAD. The validation cohort consisted of 2575 patients, 771 (29.9%) had CAD. The identified risk factors were male sex, age, smoking, hyperlipidemia, hypertension, aortic valve disease, extracardiac arteriopathy, ejection fraction <30% and diabetes mellitus. CT-valve score could identify a third of the population with a risk about 10%. A score based on risk factors of CAD can identify patients that might benefit from using MSCT as a gatekeeper to CAG prior to heart valve surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Valve

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.

  18. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    PubMed

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    aortic valve-ascending thoracic aortic aneurysm 99th-percentile circumferential stresses were 548 kPa versus 462 kPa (P = .033) for tricuspid aortic valve-ascending thoracic aortic aneurysms, which also did not correlate to bicuspid aortic valve-ascending thoracic aortic aneurysm diameter (r = 0.007). Circumferential and longitudinal stresses were greater in bicuspid aortic valve- than tricuspid aortic valve-ascending thoracic aortic aneurysms and were more pronounced in the sinotubular junction. Peak wall stress did not correlate with bicuspid aortic valve-ascending thoracic aortic aneurysm diameter, suggesting diameter alone in this population may be a poor predictor of dissection risk. Our results highlight the need for patient-specific aneurysm wall stress analysis for accurate dissection risk prediction. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. Fungal prosthetic valve endocarditis with mycotic aneurysm: Case report.

    PubMed

    Brandão, Mariana; Almeida, Jorge; Ferraz, Rita; Santos, Lurdes; Pinho, Paulo; Casanova, Jorge

    2016-09-01

    Fungal prosthetic valve endocarditis is an extremely severe form of infective endocarditis, with poor prognosis and high mortality despite treatment. Candida albicans is the most common etiological agent for this rare but increasingly frequent condition. We present a case of fungal prosthetic valve endocarditis due to C. albicans following aortic and pulmonary valve replacement in a 38-year-old woman with a history of surgically corrected tetralogy of Fallot, prior infective endocarditis and acute renal failure with need for catheter-based hemodialysis. Antifungal therapy with liposomal amphotericin B was initiated prior to cardiac surgery, in which the bioprostheses were replaced by homografts, providing greater resistance to recurrent infection. During hospitalization, a mycotic aneurysm was diagnosed following an episode of acute arterial ischemia, requiring two vascular surgical interventions. Despite the complications, the patient's outcome was good and she was discharged on suppressive antifungal therapy with oral fluconazole for at least a year. The reported case illustrates multiple risk factors for fungal endocarditis, as well as complications and predictors of poor prognosis, demonstrating its complexity. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Multi-port valve assembly

    DOEpatents

    Guggenheim, S. Frederic

    1986-01-01

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.