Sample records for vapor bypass assembly

  1. Minimally invasive entero-enteral dual-path bypass using self-assembling magnets.

    PubMed

    Ryou, Marvin; Aihara, Hiroyuki; Thompson, Christopher C

    2016-10-01

    A minimally invasive method of entero-enteral bypass may be desirable for treatment of obstruction, obesity, or metabolic syndrome. We have developed a technology based on miniature self-assembling magnets which create large-caliber anastomoses (incisionless anastomosis system or IAS). The aim of this study was to assess (a) procedural characteristics of IAS deployment and (b) long-term integrity and patency of the resulting jejuno-ileal dual-path bypass. Endoscopic jejuno-ileal bypass creation using IAS magnets was performed in 8 Yorkshire pigs survived 3 months. The jejunal magnet was endoscopically deployed. However, the ileal magnet required surgical delivery given restraints of porcine anatomy. A 5-mm enterotomy was created through which the ileal magnet was inserted using a modified laparoscopic delivery tool. Magnets were manually coupled. Pigs underwent serial endoscopies for anastomosis assessment. Three-month necropsies were performed, followed by pressure testing of anastomoses and histological analysis. Jejuno-ileal bypass creation using self-assembling IAS magnets was successful in all 8 pigs (100 %). Patent, leak-free bypasses formed in all animals by day 10. All IAS magnets were expelled by day 12. Anastomoses were widely patent at 3 months, with mean maximal diameter of 30 mm. At necropsy, adhesions were minimal. Pressure testing confirmed superior integrity of anastomotic tissue. Histology showed full epithelialization across the anastomosis with no evidence of submucosal fibrosis or inflammation. Entero-enteral bypass using self-assembling IAS magnets is safe and technically feasible in the porcine model. IAS magnets can be rapidly delivered endoscopically or through a modified laparoscopic device. Expulsion of fused magnets avoids retention of prosthetic material. Anastomoses are widely patent and fully re-epithelialized. Three-month pressure testing reveals anastomotic tissue to be as robust as native tissue, while necropsy and histology

  2. Vacuum vapor deposition gun assembly

    DOEpatents

    Zeren, Joseph D.

    1985-01-01

    A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

  3. Bypassing multidrug resistance in human breast cancer cells with lipid/polymer particle assemblies

    PubMed Central

    Li, Bo; Xu, Hui; Li, Zhen; Yao, Mingfei; Xie, Meng; Shen, Haijun; Shen, Song; Wang, Xinshi; Jin, Yi

    2012-01-01

    Background Multidrug resistance (MDR) mediated by the overexpression of adenosine triphosphate (ATP)-binding cassette (ABC) transporters, such as P-glycoprotein (P-gp), remains one of the major obstacles to effective cancer chemotherapy. In this study, lipid/particle assemblies named LipoParticles (LNPs), consisting of a dimethyldidodecylammonium bromide (DMAB)-modified poly(lactic-co-glycolic acid) (PLGA) nanoparticle core surrounded by a 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) shell, were specially designed for anticancer drugs to bypass MDR in human breast cancer cells that overexpress P-gp. Methods Doxorubicin (DOX), a chemotherapy drug that is a P-gp substrate, was conjugated to PLGA and encapsulated in the self-assembled LNP structure. Physiochemical properties of the DOX-loaded LNPs were characterized in vitro. Cellular uptake, intracellular accumulation, and cytotoxicity were compared in parental Michigan Cancer Foundation (MCF)-7 cells and P-gp-overexpressing, resistant MCF-7/adriamycin (MCF-7/ADR) cells. Results This study found that the DOX formulated in LNPs showed a significantly increased accumulation in the nuclei of drug-resistant cells relative to the free drug, indicating that LNPs could alter intracellular traffic and bypass drug efflux. The cytotoxicity of DOX loaded-LNPs had a 30-fold lower half maximal inhibitory concentration (IC50) value than free DOX in MCF-7/ADR, measured by the colorimetric cell viability (MTT) assay, correlated with the strong nuclear retention of the drug. Conclusion The results show that this core-shell lipid/particle structure could be a promising strategy to bypass MDR. PMID:22275834

  4. Heat exchanger bypass system for an absorption refrigeration system

    DOEpatents

    Reimann, Robert C.

    1984-01-01

    A heat exchanger bypass system for an absorption refrigeration system is disclosed. The bypass system operates to pass strong solution from the generator around the heat exchanger to the absorber of the absorption refrigeration system when strong solution builds up in the generator above a selected level indicative of solidification of strong solution in the heat exchanger or other such blockage. The bypass system includes a bypass line with a gooseneck located in the generator for controlling flow of strong solution into the bypass line and for preventing refrigerant vapor in the generator from entering the bypass line during normal operation of the refrigeration system. Also, the bypass line includes a trap section filled with liquid for providing a barrier to maintain the normal pressure difference between the generator and the absorber even when the gooseneck of the bypass line is exposed to refrigerant vapor in the generator. Strong solution, which may accumulate in the trap section of the bypass line, is diluted, to prevent solidification, by supplying weak solution to the trap section from a purge system for the absorption refrigeration system.

  5. Skylab communications carrier 16536G and filter bypass adapter assembly 12535G. [development of communications equipment for use with Skylab spacecraft

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Communications equipment for use with the Skylab project is examined to show compliance with contract requirements. The items of equipment considered are: (1) communications carrier assemblies, (2) filter bypass adapter assemblies, and (3) sub-assemblies, parts, and repairs. Additional information is provided concerning contract requirements, test requirements, and failure investigation actions.

  6. Endoscopic intestinal bypass creation by using self-assembling magnets in a porcine model.

    PubMed

    Ryou, Marvin; Agoston, A Tony; Thompson, Christopher C

    2016-04-01

    A purely endoluminal method of GI bypass would be desirable for the treatment of obstruction, obesity, or metabolic syndrome. We have developed a technology based on miniature self-assembling magnets that create large-caliber anastomoses (Incisionless Anastomosis System [IAS]). The aim of this study was to evaluate procedural characteristics of IAS deployment and long-term anastomotic integrity and patency. We performed a 3-month survival study of Yorkshire pigs (5 interventions, 3 controls). Intervention pigs underwent simultaneous enteroscopy/colonoscopy performed with the animals under intravenous sedation. The IAS magnets were deployed and coupled with reciprocal magnets under fluoroscopy. Every 3 to 6 days pigs underwent endoscopy until jejunocolonic anastomosis (dual-path bypass) creation and magnet expulsion. Necropsies and histological evaluation were performed. The primary endpoints were technical success; secondary endpoints of anastomosis integrity, patency, and histological characteristics were weight trends. Under intravenous sedation, endoscopic bypass creation by using IAS magnets was successfully performed in 5 of 5 pigs (100%). Given porcine anatomy, the easiest dual-path bypass to create was between the proximal jejunum and colon. The mean procedure time was 14.7 minutes. Patent, leak-free anastomoses formed by day 4. All IAS magnets were expelled by day 12. All anastomoses were fully patent at 3 months with a mean diameter of 3.5 cm. The mean 3-month weight was 45 kg in bypass pigs and 78 kg in controls (P = .01). At necropsy, adhesions were absent. Histology showed full re-epithelialization across the anastomosis without fibrosis or inflammation. Large-caliber, leak-free, foreign body-free endoscopic intestinal bypass by using IAS magnets can be safely and rapidly performed in the porcine by model using only intravenous sedation. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  7. Chronic exposure to particulate chromate induces spindle assembly checkpoint bypass in human lung cells.

    PubMed

    Wise, Sandra S; Holmes, Amie L; Xie, Hong; Thompson, W Douglas; Wise, John Pierce

    2006-11-01

    One of the hallmarks of lung cancer is chromosome instability (CIN), particularly a tetraploid phenotype, which is normally prevented by the spindle assembly checkpoint. Hexavalent chromium Cr(VI) is an established human lung carcinogen, and Cr(VI) induces tumors at lung bifurcation sites where Cr(VI) particles impact and persist. However, the effects of Cr(VI) on the spindle assembly checkpoint are unknown and little is known about prolonged exposure to particulate Cr(VI). Accordingly, we investigated particulate Cr(VI)-induced bypass of the spindle assembly checkpoint after several days of exposure in WHTBF-6 cells. We found that lead chromate indeed induces spindle assembly checkpoint bypass in human lung cells, as 72, 96, and 120 h treatments with 0.5 or 1 microg/cm2 lead chromate induced significant increases in the percentage of cells with aberrant mitotic figures. For example, treatment with 1 microg/cm2 lead chromate for 96 h induced 11, 12.3, and 14% of cells with premature anaphase, centromere spreading and premature centromere division, respectively. In addition, we found a disruption of mitosis with more cells accumulating in anaphase; cells treated for 96 h increased from 18% in controls to 31% in cells treated with lead chromate. To confirm involvement of the spindle assembly checkpoint, Mad2 expression was used as a marker. Mad2 expression was decreased in cells exposed to chronic treatments of lead chromate, consistent with disruption of the checkpoint. We also found concentration- and time-dependent increases in tetraploid cells, which continued to grow and form colonies. When cells were treated with chronic lead alone there was no increase in aberrant mitotic cells or polyploidy; however, chronic exposure to a soluble Cr(VI) showed an increase in aberrant mitotic cells and polyploidy. These data suggest that lead chromate does induce CIN and may be one mechanism in the development of Cr(VI)-induced lung cancer.

  8. Photovoltaic module bypass diode encapsulation

    NASA Technical Reports Server (NTRS)

    Shepard, N. J., Jr.

    1983-01-01

    The design and processing techniques necessary to incorporate bypass diodes within the module encapsulant are presented. The Semicon PN junction diode cells were selected. Diode junction to heat spreader thermal resistance measurements, performed on a variety of mounted diode chip types and sizes, have yielded values which are consistently below 1 deg C per watt, but show some instability when thermally cycled over the temperature range from -40 to 150 deg C. Three representative experimental modules, each incorporating integral bypass diode/heat spreader assemblies of various sizes, were designed. Thermal testing of these modules enabled the formulation of a recommended heat spreader plate sizing relationship. The production cost of three encapsulated bypass diode/heat spreader assemblies were compared with similarly rated externally mounted packaged diodes. It is concluded that, when proper designed and installed, these bypass diode devices will improve the overall reliability of a terrestrial array over a 20 year design lifetime.

  9. Measurement of Trace Water Vapor in a Carbon Dioxide Removal Assembly Product Stream

    NASA Technical Reports Server (NTRS)

    Wormhoudt, Joda; Shorter, Joanne H.; McManus, J. Barry; Nelson, David D.; Zahniser, Mark S.; Freedman, Andrew; Campbell, Melissa; Chang, Clarence T.; Smith, Frederick D.

    2004-01-01

    The International Space Station Carbon Dioxide Removal Assembly (CDRA) uses regenerable adsorption technology to remove carbon dioxide (COP) from cabin air. Product water vapor measurements from a CDRA test bed at the NASA Marshall Space Flight Center were made using a tunable infrared diode laser differential absorption spectrometer (TILDAS) provided by NASA Glenn Research Center. The TILDAS instrument exceeded all the test specifications, including sensitivity, dynamic range, time response, and unattended operation. During the COP desorption phase, water vapor concentrations as low as 5 ppmv were observed near the peak of CO2 evolution, rising to levels of approx. 40 ppmv at the end of a cycle. Periods of high water concentration (>100 ppmv) were detected and shown to be caused by an experimental artifact. Measured values of total water vapor evolved during a single desorption cycle were as low as 1 mg.

  10. Idle speed and fuel vapor recovery control system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orzel, D.V.

    1993-06-01

    A method for controlling idling speed of an engine via bypass throttle connected in parallel to a primary engine throttle and for controlling purge flow through a vapor recovery system into an air/fuel intake of the engine is described, comprising the steps of: positioning the bypass throttle to decrease any difference between a desired engine idle speed and actual engine idle speed; and decreasing the purge flow when said bypass throttle position is less than a preselected fraction of a maximum bypass throttle position.

  11. Polyethylene-Glycol-Mediated Self-Assembly of Magnetite Nanoparticles at the Liquid/Vapor Interface

    DOE PAGES

    Vaknin, David; Wang, Wenjie; Islam, Farhan; ...

    2018-03-23

    It is shown that magnetite nanoparticles (MagNPs) grafted with polyethylene glycol (PEG) self-assemble and short-range-order as 2D films at surfaces of aqueous suspensions by manipulating salt concentrations. Synchrotron X-ray reflectivity and grazing-incidence small angle X-ray scattering studies reveal that K 2CO 3 induces the migration of the PEG-MagNPs to the liquid/vapor interface to form a Gibbs layer of monoparticle in thickness. As the salt concentration and/or nanoparticle concentration increase, the surface-adsorbed nanoparticles become more organized. And further increase in salt concentration leads to the growth of an additional incomplete nanoparticle layer contiguous to the first one at the vapor/liquid interfacemore » that remains intact.« less

  12. Polyethylene-Glycol-Mediated Self-Assembly of Magnetite Nanoparticles at the Liquid/Vapor Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaknin, David; Wang, Wenjie; Islam, Farhan

    It is shown that magnetite nanoparticles (MagNPs) grafted with polyethylene glycol (PEG) self-assemble and short-range-order as 2D films at surfaces of aqueous suspensions by manipulating salt concentrations. Synchrotron X-ray reflectivity and grazing-incidence small angle X-ray scattering studies reveal that K 2CO 3 induces the migration of the PEG-MagNPs to the liquid/vapor interface to form a Gibbs layer of monoparticle in thickness. As the salt concentration and/or nanoparticle concentration increase, the surface-adsorbed nanoparticles become more organized. And further increase in salt concentration leads to the growth of an additional incomplete nanoparticle layer contiguous to the first one at the vapor/liquid interfacemore » that remains intact.« less

  13. Making a mixed-model line more efficient and flexible by introducing a bypass line

    NASA Astrophysics Data System (ADS)

    Matsuura, Sho; Matsuura, Haruki; Asada, Akiko

    2017-04-01

    This paper provides a design procedure for the bypass subline in a mixed-model assembly line. The bypass subline is installed to reduce the effect of the large difference in operation times among products assembled together in a mixed-model line. The importance of the bypass subline has been increasing in association with the rising necessity for efficiency and flexibility in modern manufacturing. The main topics of this paper are as follows: 1) the conditions in which the bypass subline effectively functions, and 2) how the load should be distributed between the main line and the bypass subline, depending on production conditions such as degree of difference in operation times among products and the mixing ratio of products. To address these issues, we analyzed the lower and the upper bounds of the line length. Based on the results, a design procedure and a numerical example are demonstrated.

  14. Inhibition of CDK7 bypasses spindle assembly checkpoint via premature cyclin B degradation during oocyte meiosis.

    PubMed

    Wang, HaiYang; Jo, Yu-Jin; Sun, Tian-Yi; Namgoong, Suk; Cui, Xiang-Shun; Oh, Jeong Su; Kim, Nam-Hyung

    2016-12-01

    To ensure accurate chromosome segregation, the spindle assembly checkpoint (SAC) delays anaphase onset by preventing the premature activation of anaphase-promoting complex/cyclosome (APC/C) until all kinetochores are attached to the spindle. Although an escape from mitosis in the presence of unsatisfied SAC has been shown in several cancer cells, it has not been reported in oocyte meiosis. Here, we show that CDK7 activity is required to prevent a bypass of SAC during meiosis I in mouse oocytes. Inhibition of CDK7 using THZ1 accelerated the first meiosis, leading to chromosome misalignment, lag of chromosomes during chromosome segregation, and a high incidence of aneuploidy. Notably, this acceleration occurred in the presence of SAC proteins including Mad2 and Bub3 at the kinetochores. However, inhibition of APC/C-mediated cyclin B degradation blocked the THZ1-induced premature polar body extrusion. Moreover, chromosomal defects mediated by THZ1 were rescued when anaphase onset was delayed. Collectively, our results show that CDK7 activity is required to prevent premature anaphase onset by suppressing the bypass of SAC, thus ensuring chromosome alignment and proper segregation. These findings reveal new roles of CDK7 in the regulation of meiosis in mammalian oocytes. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Design, construction, and testing a purpose-built climate-controlled solvent vapor annealing chamber for guided self-assembly of block polymer thin films

    NASA Astrophysics Data System (ADS)

    Gnabasik, Ryan; Haase, Rustin; Baruth, Andrew

    2014-03-01

    Despite its efficacy to produce well-ordered, periodic nanostructures, the intricate role multiple parameters play in solvent vapor annealing has not been fully established. In solvent vapor annealing a thin polymer film is exposed to the vapors of a solvent(s) thus forming a swollen and mobile layer to direct the self-assembly process at the nanoscale. Recent developments in both theory and experiment have directly identified critical parameters, but controlling them in any systematic way has proven non-trivial. These identified parameters include vapor pressure, solvent concentration in the film, and, critically, the solvent evaporation rate. To explore their role, a purpose-built solvent vapor annealing chamber was designed and constructed. The all-metal chamber is inert to solvent exposure and pneumatically actuated valves allow for precision timing in the introduction and withdrawal of solvent vapor. Furthermore, the mass flow controlled inlet, chamber pressure gauges, in situ spectral reflectance-based thickness monitoring, and high precision micrometer relief valve, give real-time monitoring and control during the annealing and evaporation phases. Using atomic force microscopy to image the annealed films, we are able to map out the parameter space for a series of polystyrene- b-polylactide (Mn = 75 kg/mol and fPLA = 0.28) block polymer thin films with an intrinsic cylindrical morphology and identify their role in directed assembly. Funded by Creighton University Summer Research Grant.

  16. Tailoring the vapor-liquid-solid growth toward the self-assembly of GaAs nanowire junctions.

    PubMed

    Dai, Xing; Dayeh, Shadi A; Veeramuthu, Vaithianathan; Larrue, Alexandre; Wang, Jian; Su, Haibin; Soci, Cesare

    2011-11-09

    New insights into understanding and controlling the intriguing phenomena of spontaneous merging (kissing) and the self-assembly of monolithic Y- and T-junctions is demonstrated in the metal-organic chemical vapor deposition growth of GaAs nanowires. High-resolution transmission electron microscopy for determining polar facets was coupled to electrostatic-mechanical modeling and position-controlled synthesis to identify nanowire diameter, length, and pitch, leading to junction formation. When nanowire patterns are designed so that the electrostatic energy resulting from the interaction of polar surfaces exceeds the mechanical energy required to bend the nanowires to the point of contact, their fusion can lead to the self-assembly of monolithic junctions. Understanding and controlling this phenomenon is a great asset for the realization of dense arrays of vertical nanowire devices and opens up new ways toward the large scale integration of nanowire quantum junctions or nanowire intracellular probes.

  17. Method for the generation of variable density metal vapors which bypasses the liquidus phase

    DOEpatents

    Kunnmann, Walter; Larese, John Z.

    2001-01-01

    The present invention provides a method for producing a metal vapor that includes the steps of combining a metal and graphite in a vessel to form a mixture; heating the mixture to a first temperature in an argon gas atmosphere to form a metal carbide; maintaining the first temperature for a period of time; heating the metal carbide to a second temperature to form a metal vapor; withdrawing the metal vapor and the argon gas from the vessel; and separating the metal vapor from the argon gas. Metal vapors made using this method can be used to produce uniform powders of the metal oxide that have narrow size distribution and high purity.

  18. High quality factor whispering gallery modes from self-assembled hexagonal GaN rods grown by metal-organic vapor phase epitaxy.

    PubMed

    Tessarek, C; Sarau, G; Kiometzis, M; Christiansen, S

    2013-02-11

    Self-assembled GaN rods were grown on sapphire by metal-organic vapor phase epitaxy using a simple two-step method that relies first on a nitridation step followed by GaN epitaxy. The mask-free rods formed without any additional catalyst. Most of the vertically aligned rods exhibit a regular hexagonal shape with sharp edges and smooth sidewall facets. Cathodo- and microphotoluminescence investigations were carried out on single GaN rods. Whispering gallery modes with quality factors greater than 4000 were measured demonstrating the high morphological and optical quality of the self-assembled GaN rods.

  19. Heart bypass surgery

    MedlinePlus

    Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...

  20. Vapor-phase-processed fluorinated self-assembled monolayer for organic thin-film transistors

    NASA Astrophysics Data System (ADS)

    Roh, Jeongkyun; Lee, Changhee; Kwak, Jeonghun; Jung, Byung Jun; Kim, Hyeok

    2015-09-01

    A vapor-phase-processed fluorinated silazane self-assembled monolayer (SAM), 1,3-bis(trifluoropropyl)-1,1,3,3-tetramethyldisilazane (FPDS), was introduced as a surface modifier for pentacene-based organic thin-film transistors (OTFTs). A remarkable improvement in the field effect mobility from 0.25 cm2/Vs (without SAM-treatment) to 0.42 cm2/Vs (with FPDS-treatment) was observed, which was attributed to the better pentacene growth on a hydrophobic surface. A significant reduction in the contact resistance was also observed by FPDS treatment due to the improved bulk conductivity and diminished charge trapping at the gate dielectric surface by the SAM treatment. In addition, FPDS treatment efficiently improved the bias stability of the OTFTs; the drain-to-source current degradation by the bias stress was greatly reduced from 80% to 50% by FPDS treatment, and the characteristic time for charge trapping of the FPDS treated OTFTs was approximately one order of magnitude larger than that of the OTFTs without SAM treatment.

  1. Preliminary characterization of a water vaporizer for resistojet applications

    NASA Technical Reports Server (NTRS)

    Morren, W. Earl

    1992-01-01

    A series of tests was conducted to explore the characteristics of a water vaporizer intended for application to resistojet propulsion systems. The objectives of these tests were to (1) observe the effect of orientation with respect to gravity on vaporizer stability, (2) characterize vaporizer efficiency and outlet conditions over a range of flow rates, and (3) measure the thrust performance of a vaporizer/resistojet thruster assembly. A laboratory model of a forced-flow, once-through water vaporizer employing a porous heat exchange medium was built and characterized over a range of flow rates and power levels of interest for application to water resistojets. In a test during which the vaporizer was rotated about a horizontal axis normal to its own axis, the outlet temperature and mass flow rate through the vaporizer remained steady. Throttlability to 30 percent of the maximum flow rate tested was demonstrated. The measured thermal efficiency of the vaporizer was near 0.9 for all tests. The water vaporizer was integrated with an engineering model multipropellant resistojet. Performance of the vaporizer/thruster assembly was measured over a narrow range of operating conditions. The maximum specific impulse measured was 234 s at a mass flow rate and specific power level (vaporizer and thruster combined) of 154 x 10(exp-6)kg/s and 6.8 MJ/kg, respectively.

  2. Bypass control valve seal and bearing life cycle test report

    NASA Technical Reports Server (NTRS)

    Lundback, A. V.

    1972-01-01

    The operating characteristics of a bypass control valve seal and bearing life cycle tests are reported. Data from the initial assembly, leak, torque, and deflection tests are included along with the cycle life test results and conclusions. The equipment involved was to be used in the nuclear engine for the rocket vehicles program.

  3. Copper vapor laser modular packaging assembly

    DOEpatents

    Alger, Terry W.; Ault, Earl R.; Moses, Edward I.

    1992-01-01

    A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment.

  4. Experimental verification of the vaporization's contribution to the shock waves generated by underwater electrical wire explosion under micro-second timescale pulsed discharge

    NASA Astrophysics Data System (ADS)

    Han, Ruoyu; Zhou, Haibin; Wu, Jiawei; Clayson, Thomas; Ren, Hang; Wu, Jian; Zhang, Yongmin; Qiu, Aici

    2017-06-01

    This paper studies pressure waves generated by exploding a copper wire in a water medium, demonstrating the significant contribution of the vaporization process to the formation of shock waves. A test platform including a pulsed current source, wire load, chamber, and diagnostic system was developed to study the shock wave and optical emission characteristics during the explosion process. In the experiment, a total of 500 J was discharged through a copper wire load 0.2 mm in diameter and 4 cm in length. A water gap was installed adjacent to the load so that the current was diverted away from the load after breakdown occurred across the water gap. This allows the electrical energy injection into the load to be interrupted at different times and at different stages of the wire explosion process. Experimental results indicate that when the load was bypassed before the beginning of the vaporization phase, the measured peak pressure was less than 2.5 MPa. By contrast, the peak pressure increased significantly to over 6.5 MPa when the water gap broke down after the beginning of the vaporization phase. It was also found that when bypassing the load after the voltage peak, similar shock waves were produced to those from a non-bypassed load. However, the total optical emission of these bypassed loads was at least an order of magnitude smaller. These results clearly demonstrate that the vaporization process is vital to the formation of shock waves and the energy deposited after the voltage collapse may only have a limited effect.

  5. Copper vapor laser modular packaging assembly

    DOEpatents

    Alger, T.W.; Ault, E.R.; Moses, E.I.

    1992-12-01

    A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment. 2 figs.

  6. Tricks, tips, and literature review on the adapted vaporize system to deliver volatile agents during cardiopulmonary bypass

    PubMed Central

    Nigro Neto, Caetano; De Simone, Francesco; Cassarà, Luigi; Dos Santos Silva, Carlos Gustavo; Maranhão Cardoso, Thiago Augusto Almeida; Carcò, Francesco; Zangrillo, Alberto; Landoni, Giovanni

    2016-01-01

    Background: Recently, evidence of cardio-protection and reduction in mortality due to the use of volatile agents during cardiac surgery led to an increase in their use during cardiopulmonary bypass (CPB). These findings seem to be enhanced when the volatile agents are used during all the surgical procedure, including the CPB period. Aims: Since the administration of volatile agents through CPB can be beneficial to the patients, we decided to review the use of volatile agents vaporized in the CPB circuit and to summarize some tricks and tips of this technique using our 10-year experience of Brazilian and Italian centers with a large volume of cardiac surgeries. Study Setting: Hospital. Methods: A literature review. Results: During the use of the volatile agents in CPB, it is very important to analyze all gases that come in and go out of the membrane oxygenators. The proper monitoring of inhaled and exhaled fraction of the gas allows not only monitoring of anesthesia level, but also the detection of possible leakage in the circuit. Any volatile agent in the membrane oxygenator is supposed to pollute the operating theater. This is the major reason why proper scavenging systems are always necessary when this technique is used. Conclusion: While waiting for industry upgrades, we recommend that volatile agents should be used during CPB only by skilled perfusionists and physicians with the aim to reduce postoperative morbidity and mortality. PMID:27052063

  7. Analyses of 1/15 scale Creare bypass transient experiments. [PWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kmetyk, L.N.; Buxton, L.D.; Cole, R.K. Jr.

    1982-09-01

    RELAP4 analyses of several 1/15 scale Creare H-series bypass transient experiments have been done to investigate the effect of using different downcomer nodalizations, physical scales, slip models, and vapor fraction donoring methods. Most of the analyses were thermal equilibrium calculations performed with RELAP4/MOD5, but a few such calculations were done with RELAP4/MOD6 and RELAP4/MOD7, which contain improved slip models. In order to estimate the importance of nonequilibrium effects, additional analyses were performed with TRAC-PD2, RELAP5 and the nonequilibrium option of RELAP4/MOD7. The purpose of these studies was to determine whether results from Westinghouse's calculation of the Creare experiments, which weremore » done with a UHI-modified version of SATAN, were sufficient to guarantee SATAN would be conservative with respect to ECC bypass in full-scale plant analyses.« less

  8. Coronary–Coronary Bypass

    PubMed Central

    Erdil, Nevzat; Ates, Sanser; Demirkilic, Ufuk; Tatar, Harun; Sag, Cemal

    2002-01-01

    There is increased risk of systemic embolism during cardiopulmonary bypass in patients with a severely atherosclerotic ascending aorta. We report a coronary–coronary bypass in a 74-year-old man with a porcelain aorta. He underwent a proximal right coronary–distal right coronary artery bypass with a saphenous vein graft, combined with a pedicled arterial graft (left internal mammary artery) to the left anterior descending artery, in the presence of a beating heart without cardiopulmonary bypass. The patient survived without evidence of perioperative myocardial infarction or cerebrovascular accident. One year later, follow-up angiography showed graft patency with good distal runoff. Coronary–coronary bypass on a beating heart without cardiopulmonary bypass can be performed safely in a patient with porcelain aorta. (Tex Heart Inst J 2002;29:54–5) PMID:11995853

  9. Gastric bypass surgery - discharge

    MedlinePlus

    ... bypass - discharge; Gastric bypass - Roux-en-Y - discharge; Obesity gastric bypass discharge; Weight loss - gastric bypass discharge ... al. Bariatric surgery versus non-surgical treatment for obesity: a systematic review and meta-analysis of randomised ...

  10. California bypass study : the economic impacts of bypasses.

    DOT National Transportation Integrated Search

    2006-05-01

    The California Department of Transportation (Caltrans) sponsored the California : Bypass Study to improve basic knowledge about the impacts of bypasses on small-town : economies. The study included an investigation into the economic impacts of recent...

  11. High-speed assembly language (80386/80387) programming for laser spectra scan control and data acquisition providing improved resolution water vapor spectroscopy

    NASA Technical Reports Server (NTRS)

    Allen, Robert J.

    1988-01-01

    An assembly language program using the Intel 80386 CPU and 80387 math co-processor chips was written to increase the speed of data gathering and processing, and provide control of a scanning CW ring dye laser system. This laser system is used in high resolution (better than 0.001 cm-1) water vapor spectroscopy experiments. Laser beam power is sensed at the input and output of white cells and the output of a Fabry-Perot. The assembly language subroutine is called from Basic, acquires the data and performs various calculations at rates greater than 150 faster than could be performed by the higher level language. The width of output control pulses generated in assembly language are 3 to 4 microsecs as compared to 2 to 3.7 millisecs for those generated in Basic (about 500 to 1000 times faster). Included are a block diagram and brief description of the spectroscopy experiment, a flow diagram of the Basic and assembly language programs, listing of the programs, scope photographs of the computer generated 5-volt pulses used for control and timing analysis, and representative water spectrum curves obtained using these programs.

  12. Chronic Exposure to Zinc Chromate Induces Centrosome Amplification and Spindle Assembly Checkpoint Bypass in Human Lung Fibroblasts

    PubMed Central

    Holmes, Amie L.; Wise, Sandra S.; Pelsue, Stephen C.; Aboueissa, AbouEl-Makarim; Lingle, Wilma; Salisbury, Jeffery; Gallagher, Jamie; Wise, John Pierce

    2010-01-01

    Hexavalent chromium (Cr(VI)) compounds are known human lung carcinogens. Solubility plays an important role in its carcinogenicity with the particulate or insoluble form being the most potent. Of the particulate Cr(VI) compounds, zinc chromate appears to be the most potent carcinogen, however, very few studies have investigated its carcinogenic mechanism. In this study, we investigated the ability of chronic exposure to zinc chromate to induce numerical chromosome instability. We found no increase in aneuploidy after a 24 hour exposure to zinc chromate, but with more chronic exposures, zinc chromate induced concentration- and time-dependent increases in aneuploidy in the form of hypodiploidy, hyperdiploidy and tetraploidy. Zinc chromate also induced centrosome amplification in a concentration- and time-dependent manner in both interphase and mitotic cells after chronic exposure, producing cells with centriolar defects. Further, chronic exposure to zinc chromate induced concentration- and time-dependent increases in spindle assembly checkpoint bypass with increases in centromere spreading, premature centromere division and premature anaphase. Lastly, we found that chronic exposure to zinc chromate induced a G2 arrest. All together, these data indicate that zinc chromate can induce chromosome instability after prolonged exposures. PMID:20030412

  13. Metal vapor laser including hot electrodes and integral wick

    DOEpatents

    Ault, Earl R.; Alger, Terry W.

    1995-01-01

    A metal vapor laser, specifically one utilizing copper vapor, is disclosed herein. This laser utilizes a plasma tube assembly including a thermally insulated plasma tube containing a specific metal, e.g., copper, and a buffer gas therein. The laser also utilizes means including hot electrodes located at opposite ends of the plasma tube for electrically exciting the metal vapor and heating its interior to a sufficiently high temperature to cause the metal contained therein to vaporize and for subjecting the vapor to an electrical discharge excitation in order to lase. The laser also utilizes external wicking arrangements, that is, wicking arrangements located outside the plasma tube.

  14. Metal vapor laser including hot electrodes and integral wick

    DOEpatents

    Ault, E.R.; Alger, T.W.

    1995-03-07

    A metal vapor laser, specifically one utilizing copper vapor, is disclosed herein. This laser utilizes a plasma tube assembly including a thermally insulated plasma tube containing a specific metal, e.g., copper, and a buffer gas therein. The laser also utilizes means including hot electrodes located at opposite ends of the plasma tube for electrically exciting the metal vapor and heating its interior to a sufficiently high temperature to cause the metal contained therein to vaporize and for subjecting the vapor to an electrical discharge excitation in order to lase. The laser also utilizes external wicking arrangements, that is, wicking arrangements located outside the plasma tube. 5 figs.

  15. High speed door assembly

    DOEpatents

    Shapiro, Carolyn

    1993-01-01

    A high speed door assembly, comprising an actuator cylinder and piston rods, a pressure supply cylinder and fittings, an electrically detonated explosive bolt, a honeycomb structured door, a honeycomb structured decelerator, and a structural steel frame encasing the assembly to close over a 3 foot diameter opening within 50 milliseconds of actuation, to contain hazardous materials and vapors within a test fixture.

  16. Shaping of the axial power density distribution in the core to minimize the vapor volume fraction at the outlet of the VVER-1200 fuel assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savander, V. I.; Shumskiy, B. E., E-mail: borisshumskij@yandex.ru; Pinegin, A. A.

    The possibility of decreasing the vapor fraction at the VVER-1200 fuel assembly outlet by shaping the axial power density field is considered. The power density field was shaped by axial redistribution of the concentration of the burnable gadolinium poison in the Gd-containing fuel rods. The mathematical modeling of the VVER-1200 core was performed using the NOSTRA computer code.

  17. High speed door assembly

    DOEpatents

    Shapiro, C.

    1993-04-27

    A high speed door assembly is described, comprising an actuator cylinder and piston rods, a pressure supply cylinder and fittings, an electrically detonated explosive bolt, a honeycomb structured door, a honeycomb structured decelerator, and a structural steel frame encasing the assembly to close over a 3 foot diameter opening within 50 milliseconds of actuation, to contain hazardous materials and vapors within a test fixture.

  18. Condenser assembly system for an appliance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litch, Andrew David

    2017-10-17

    An appliance includes a compact condenser assembly formed with at least two separately and independently produced wire on tube condensers. Each of the at least two wire on tube condensers has a condenser inlet and a condenser outlet. The at least two wire on tube condensers are at least substantially locked and positioned in a matingly engaged configuration forming a compact condenser assembly. The at least two wire on tube condensers are configured to be operationally connected in at least one of a parallel configuration, a series configuration, a selectable configuration, and a bypass configuration.

  19. Distal small bowel bypass for weight regain after gastric bypass: safety and efficacy threshold occurs at <70% bypass.

    PubMed

    Caruana, Joseph A; Monte, Scott V; Jacobs, David M; Voytovich, Catherine; Ghanim, Husam; Dandona, Paresh

    2015-01-01

    For patients with poor weight loss (WL) after Roux-en-Y gastric bypass (RYGB) there are few well-tolerated and effective surgical options. Revision to distal bypass by shortening of the common channel (CC) induces significant WL but often produces protein calorie malnutrition (PCM) and severe diarrhea. The aim of this study was to identify a safe and effective threshold for distal small bowel bypass when done for revision of gastric bypass. Academic Institution, United States. We performed revision of RYGB for WL in 20 patients by shortening the CC to a new length of 120-300 cm. The Roux limb length was unchanged. WL and PCM were monitored. A threshold for percent of small bowel bypassed at which PCM was avoided was retrospectively determined. WL was then compared in patients above and below this threshold. Five patients completed a 250-kcal mixed meal challenge before and 3 months after revision to determine selected gut hormone responses. Bypassing ≥70% small bowel resulted in PCM in 4 of 10 patients but in none of 10 patients below that threshold. PCM was observed as late as 2 years after revision and necessitated rerevision by lengthening of the CC in 3 patients. Additionally, nocturnal diarrhea was more common and more intractable when ≥70% bypass was done. Both groups had significant excess body WL over 2 years, but it was greater in patients with ≥70% bypass (47±19 versus 26±17; P<.05). A favorable gut hormone response was observed with 3-hour decrease in glucose-dependent insulinotropic peptide (GIP) by 25% and increase in glucagon-like peptide-1 (GLP-1) by 25%, whereas fasting peptide-YY (PYY) increased by 71% (P<.05 for all). Revision of RYGB to distal bypass when it is <70% of a patient's small bowel length results in an acceptable balance of WL and a positive safety profile. WL may be mediated through an enhanced gut hormone effect, an aversion to ingested fat, and possibly other mechanisms. Copyright © 2015 American Society for Bariatric

  20. The Influence of Summertime Convection Over Southeast Asia on Water Vapor in the Tropical Stratosphere

    NASA Technical Reports Server (NTRS)

    Wright, J. S.; Fu, R.; Fueglistaler, S.; Liu, Y. S.; Zhang, Y.

    2011-01-01

    The relative contributions of Southeast Asian convective source regions during boreal summer to water vapor in the tropical stratosphere are examined using Lagrangian trajectories. Convective sources are identified using global observations of infrared brightness temperature at high space and time resolution, and water vapor transport is simulated using advection-condensation. Trajectory simulations are driven by three different reanalysis data sets, GMAO MERRA, ERA-Interim, and NCEP/NCAR, to establish points of consistency and evaluate the sensitivity of the results to differences in the underlying meteorological fields. All ensembles indicate that Southeast Asia is a prominent boreal summer source of tropospheric air to the tropical stratosphere. Three convective source domains are identified within Southeast Asia: the Bay of Bengal and South Asian subcontinent (MON), the South China and Philippine Seas (SCS), and the Tibetan Plateau and South Slope of the Himalayas (TIB). Water vapor transport into the stratosphere from these three domains exhibits systematic differences that are related to differences in the bulk characteristics of transport. We find air emanating from SCS to be driest, from MON slightly moister, and from TIB moistest. Analysis of pathways shows that air detrained from convection over TIB is most likely to bypass the region of minimum absolute saturation mixing ratio over the equatorial western Pacific; however, the impact of this bypass mechanism on mean water vapor in the tropical stratosphere at 68 hPa is small 0.1 ppmv). This result contrasts with previously published hypotheses, and it highlights the challenge of properly quantifying fluxes of atmospheric humidity.

  1. Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM

    PubMed Central

    Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi

    2017-01-01

    Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027

  2. Turbine and superheater bypass evaluation. Final report. [Faster startup in cycling operation and less erosion with steam bypass systems, including bypass design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosard, D.D.; Steltz, W.G.

    1986-10-01

    Properly sized turbine and boiler bypass systems permit two-shift cycling operation of units, shorten start-up time, and reduce life expenditures of plant components. With bypasses installed, faster startups can reduce fuel costs by $100,000 per year for a typical 500-MW fossil-fired unit. This report discusses the technical characteristics of existing bypass systems and provides guidelines for sizing bypass systems to achieve economical and reliable two-shift operation. The collection and analysis of startup data from several generating units were used in conjunction with computer simulations to illustrate the effects of adding various arrangements and sizes of steam bypass systems. The report,more » which indicates that shutdown procedures have significant impact on subsequent startup and loading time, describes operating practices to optimize the effectiveness of bypass systems. To determine the effectiveness of large turbine bypass systems of less than 100% capacity in preventing boiler trips following load rejection, transient field data were compared to a load rejection simulation using the modular modeling system (MMS). The MMS was then used to predict system response to other levels of load rejection. 7 refs., 87 figs., 8 tabs.« less

  3. Stretchable Electronic Sensors of Nanocomposite Network Films for Ultrasensitive Chemical Vapor Sensing.

    PubMed

    Yan, Hong; Zhong, Mengjuan; Lv, Ze; Wan, Pengbo

    2017-11-01

    A stretchable, transparent, and body-attachable chemical sensor is assembled from the stretchable nanocomposite network film for ultrasensitive chemical vapor sensing. The stretchable nanocomposite network film is fabricated by in situ preparation of polyaniline/MoS 2 (PANI/MoS 2 ) nanocomposite in MoS 2 suspension and simultaneously nanocomposite deposition onto prestrain elastomeric polydimethylsiloxane substrate. The assembled stretchable electronic sensor demonstrates ultrasensitive sensing performance as low as 50 ppb, robust sensing stability, and reliable stretchability for high-performance chemical vapor sensing. The ultrasensitive sensing performance of the stretchable electronic sensors could be ascribed to the synergistic sensing advantages of MoS 2 and PANI, higher specific surface area, the reliable sensing channels of interconnected network, and the effectively exposed sensing materials. It is expected to hold great promise for assembling various flexible stretchable chemical vapor sensors with ultrasensitive sensing performance, superior sensing stability, reliable stretchability, and robust portability to be potentially integrated into wearable electronics for real-time monitoring of environment safety and human healthcare. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Low-Voltage Bypass Device

    NASA Technical Reports Server (NTRS)

    Wilson, J. P.

    1994-01-01

    Improved bypass device provides low-resistance current shunt around low-voltage power cell when cell fails in open-circuit condition during operation. In comparison with older bypass devices for same application, this one weighs less, generates less heat, and has lower voltage drop (less resistance). Bypass device connected in parallel with power cell. Draws very little current during normal operation of cell.

  5. Combined direct and indirect bypass for moyamoya: quantitative assessment of direct bypass flow over time.

    PubMed

    Amin-Hanjani, Sepideh; Singh, Amritha; Rifai, Hashem; Thulborn, Keith R; Alaraj, Ali; Aletich, Victor; Charbel, Fady T

    2013-12-01

    The optimal revascularization strategy for symptomatic adult moyamoya remains controversial. Whereas direct bypass offers immediate revascularization, indirect bypass can effectively induce collaterals over time. Using angiography and quantitative magnetic resonance angiography, we examined the relative contributions of direct and indirect bypass in moyamoya patients after combined direct superficial temporal artery-to-middle cerebral artery (STA-MCA) bypass and indirect encephaloduroarteriosynangiosis (EDAS). A retrospective review of moyamoya patients undergoing combined STA-MCA bypass and EDAS was conducted, excluding pediatric patients and hemorrhagic presentation. Patients with quantitative magnetic resonance angiography measurements of the direct bypass immediately and > 6 months postoperatively were included. Angiographic follow-up, when available, was used to assess EDAS collaterals at similar time intervals. Of 16 hemispheres in 13 patients, 11 (69%) demonstrated a significant (> 50%) decline in direct bypass flow at > 6 months compared with baseline, averaging a drop from 99 ± 35 to 12 ± 7 mL/min. Conversely, angiography in these hemispheres demonstrated prominent indirect collaterals, in concert with shrinkage of the STA graft. Decline in flow was apparent at a median of 9 months but was evident as early as 2 to 3 months. In this small cohort, a reciprocal relationship between direct STA bypass flow and indirect EDAS collaterals frequently occurred. This substantiates the notion that combined direct/indirect bypass can provide temporally complementary revascularization.

  6. Heart bypass surgery

    MedlinePlus Videos and Cool Tools

    Heart bypass surgery begins with an incision made in the chest, with the breastbone cut exposing the heart. Next, a portion of the saphenous vein is ... used to bypass the blocked arteries in the heart. The venous graft is sewn to the aorta ...

  7. Water vapor diffusion membrane development

    NASA Technical Reports Server (NTRS)

    Tan, M. K.

    1977-01-01

    An application of the water vapor diffusion technique is examined whereby the permeated water vapor is vented to space vacuum to alleviate on-board waste storage and provide supplemental cooling. The work reported herein deals primarily with the vapor diffusion-heat rejection (VD-HR) as it applies to the Space Shuttle. A stack configuration was selected, designed and fabricated. An asymmetric cellulose acetate membrane, used in reverse osmosis application was selected and a special spacer was designed to enhance mixing and promote mass transfer. A skid-mount unit was assembled from components used in the bench unit although no attempt was made to render it flight-suitable. The operating conditions of the VD-HR were examined and defined and a 60-day continuous test was carried out. The membranes performed very well throughout the test; no membrane rupture and no unusual flux decay was observed. In addition, a tentative design for a flight-suitable VD-HR unit was made.

  8. Dynamic Performance of High Bypass Ratio Turbine Engines With Water Ingestion

    NASA Technical Reports Server (NTRS)

    Murthy, S. N. B.

    1996-01-01

    The research on dynamic performance of high bypass turbofan engines includes studies on inlets, turbomachinery and the total engine system operating with air-water mixture; the water may be in vapor, droplet, or film form, and their combinations. Prediction codes (WISGS, WINCOF, WINCOF-1, WINCLR, and Transient Engine Performance Code) for performance changes, as well as changes in blade-casing clearance, have been established and demonstrated in application to actual, generic engines. In view of the continuous changes in water distribution in turbomachinery, the performance of both components and the total engine system must be determined in a time-dependent mode; hence, the determination of clearance changes also requires a time-dependent approach. In general, the performance and clearances changes cannot be scaled either with respect to operating or ingestion conditions. Removal of water prior to phase change is the most effective means of avoiding ingestion effects. Sufficient background has been established to perform definitive, full scale tests on a set of components and a complete engine to establish engine control and operability with various air-water vapor-water mixtures.

  9. Transverse-type laser assembly using induced electrical discharge excitation and method

    DOEpatents

    Ault, Earl R.

    1994-01-01

    A transverse-type laser assembly is disclosed herein. This assembly defines a laser cavity containing a vapor or gaseous substance which lases when subjected to specific electrical discharge excitation between a pair of spaced-apart electrodes located within the cavity in order to produce a source of light. An arrangement located entirely outside the laser cavity is provided for inducing a voltage across the electrodes within the cavity sufficient to provide the necessary electrical discharge excitation to cause a vapor substance between the electrodes to lase.

  10. Low Morbidity after Extracranial-Intracranial Bypass Operation. The Danish Extracranial-Intracranial Bypass Study: A Nationwide Survey.

    PubMed

    von Weitzel-Mudersbach, Paul; Andersen, Grethe; Rosenbaum, Sverre

    2018-06-07

    Patients with symptomatic atherosclerotic carotid artery occlusion (SACAO) have a high risk of a recurrent stroke. Extracranial-intracranial bypass (EC-IC bypass) has been shown not to improve outcome compared with medical treatment alone because long-term prevention of recurrent stroke in operated patients was offset by high perioperative stroke rates. We report our experience with EC-IC bypass operated at an experienced high-volume centre. We conducted a nationwide observational study of EC-IC bypass patients operated in the years 2007-2016 due to SACAO with ongoing clinical symptoms or progression on MRI and severe haemodynamic failure (SHF). Perioperative stroke and death within 30 days after the operation, ipsilateral stroke, bypass patency, transient ischaemic attack, and all-stroke events and deaths during long-term follow-up were registered prospectively. EC-IC bypass was performed in 48 patients with SHF and SACAO. The mean age was 64 (45-83) years. The mean follow-up was 3.6 years. The stroke rate after 30 days was 4.2%. No further ipsilateral strokes occurred during follow-up. Clinical symptoms arrested in all patients. Bypass patency rate was 94%. The perioperative stroke rate in EC-IC bypass operation, performed at a highly experienced centre, was low. During long-term follow-up, no ipsilateral stroke occurred. Consequently, EC-IC-bypass should still be considered for selected patients with SACAO, if operation can be carried out in experienced centres with low perioperative morbidity. © 2018 S. Karger AG, Basel.

  11. Your diet after gastric bypass surgery

    MedlinePlus

    Gastric bypass surgery - your diet; Obesity - diet after bypass; Weight loss - diet after bypass ... et al. American Association of Clinical Endocrinologists, The Obesity Society, and American Society for Metabolic & Bariatric Surgery ...

  12. Linitis plastica of the bypassed stomach 7 years after Roux-en-Y gastric bypass: a case report.

    PubMed

    Haenen, Filip Wn; Gys, Ben; Moreels, Tom; Michielsen, Maartje; Gys, Tobie; Lafullarde, Thierry

    2017-12-01

    Laparoscopic Roux-en-Y gastric bypass (RYGB) is currently the preferred surgical procedure to treat morbid obesity. It has proven its effects on excess weight loss and its positive effect on comorbidities. One of the main issues, however, is the post-operative evaluation of the bypassed gastric remnant. In literature, cancer of the excluded stomach after RYGB is rare. We describe the case of a 52-year-old woman with gastric linitis plastica in the bypassed stomach after Roux-en-Y gastric bypass, diagnosed by means of laparoscopy and Single-Balloon enteroscopy, and it is clinical importance. Linitis plastica of the excluded stomach after RYGB is a very rare entity. This case report shows the importance of long-term post-operative follow-up, and the importance of single-balloon enteroscopy for visualization of the bypassed stomach remnant, when other investigations remain without results. This case report is only the second report of a linitis plastica in the bypassed stomach after Roux-en-Y gastric bypass.

  13. Transverse-type laser assembly using induced electrical discharge excitation and method

    DOEpatents

    Ault, E.R.

    1994-04-19

    A transverse-type laser assembly is disclosed herein. This assembly defines a laser cavity containing a vapor or gaseous substance which lases when subjected to specific electrical discharge excitation between a pair of spaced-apart electrodes located within the cavity in order to produce a source of light. An arrangement located entirely outside the laser cavity is provided for inducing a voltage across the electrodes within the cavity sufficient to provide the necessary electrical discharge excitation to cause a vapor substance between the electrodes to lase. 3 figures.

  14. 21 CFR 870.4350 - Cardiopulmonary bypass oxygenator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass oxygenator. 870.4350... bypass oxygenator. (a) Identification. A cardiopulmonary bypass oxygenator is a device used to exchange... the FDA guidance document entitled “Guidance for Cardiopulmonary Bypass Oxygenators 510(k) Submissions...

  15. 21 CFR 870.4350 - Cardiopulmonary bypass oxygenator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass oxygenator. 870.4350... bypass oxygenator. (a) Identification. A cardiopulmonary bypass oxygenator is a device used to exchange... the FDA guidance document entitled “Guidance for Cardiopulmonary Bypass Oxygenators 510(k) Submissions...

  16. Rupture of extra-corporeal circuit tubing during cardiopulmonary bypass.

    PubMed

    Sai Krishna, Cheemalapati; Naresh Kumar, Palli Venkata; Satpathy, Soumya Kanta; Ram Mohan, Kanteti; Ramesh Babu, Vedangi

    2008-03-01

    Roller pumps are widely used for cardiopulmonary bypass in developing nations by virtue of proven safety during several years of institutional use and cost effectiveness. However, careful adjustment of roller occlusion is needed because they are known to cause spallation, tubing wear, and the occasional incident of rupture of tubing in the extracorporeal circuit. Rupture of polyvinylchloride tubing in the pump raceway during repair of a ventricular septal defect in a 4-year-old child is discussed. The event was managed by exclusion and replacement of the defective tubing during a short period of arrest. Use of an inappropriate boot pump and failure to detect its inclusion in the bypass circuit was a significant departure from protocol. However, because occlusion settings and duration of perfusion were within acceptable limits, a manufacturing flaw could also have contributed to tubing failure, and the event may or may not have been averted by the use of larger tubing. In conclusion, this incident reiterates the need for adherence to established protocol during assembly of the pump and draws attention to the fact that tubing integrity is not a guarantee and vigilance is warranted to handle its failure.

  17. Rupture of Extra-Corporeal Circuit Tubing During Cardiopulmonary Bypass

    PubMed Central

    Krishna, Cheemalapati Sai; Kumar, Palli Venkata Naresh; Satpathy, Soumya Kanta; Mohan, Kanteti Ram; Babu, Vedangi Ramesh

    2008-01-01

    Abstract: Roller pumps are widely used for cardiopulmonary bypass in developing nations by virtue of proven safety during several years of institutional use and cost effectiveness. However, careful adjustment of roller occlusion is needed because they are known to cause spallation, tubing wear, and the occasional incident of rupture of tubing in the extracorporeal circuit. Rupture of polyvinylchloride tubing in the pump raceway during repair of a ventricular septal defect in a 4-year-old child is discussed. The event was managed by exclusion and replacement of the defective tubing during a short period of arrest. Use of an inappropriate boot pump and failure to detect its inclusion in the bypass circuit was a significant departure from protocol. However, because occlusion settings and duration of perfusion were within acceptable limits, a manufacturing flaw could also have contributed to tubing failure, and the event may or may not have been averted by the use of larger tubing. In conclusion, this incident reiterates the need for adherence to established protocol during assembly of the pump and draws attention to the fact that tubing integrity is not a guarantee and vigilance is warranted to handle its failure. PMID:18389670

  18. 21 CFR 870.4230 - Cardiopulmonary bypass defoamer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass defoamer. 870.4230 Section... bypass defoamer. (a) Identification. A cardiopulmonary bypass defoamer is a device used in conjunction with an oxygenator during cardiopulmonary bypass surgery to remove gas bubbles from the blood. (b...

  19. 21 CFR 870.4230 - Cardiopulmonary bypass defoamer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass defoamer. 870.4230 Section... bypass defoamer. (a) Identification. A cardiopulmonary bypass defoamer is a device used in conjunction with an oxygenator during cardiopulmonary bypass surgery to remove gas bubbles from the blood. (b...

  20. Vapor deposition and characterization of supramolecular assemblies for integrated nonlinear optics

    NASA Astrophysics Data System (ADS)

    Esembeson, Bweh

    Very recently, some organic molecules have been developed that are very compact and have exceptionally high molecular polarizabilities which approach the fundamental quantum limit. Supramolecular assemblies created from such highly nonlinear molecules could find applications in integrated nonlinear optics such as all-optical signal processing, electro-optic modulators and frequency conversion. In this work, we have constructed a versatile vacuum deposition system for the creation of organic thin films from these molecules that can be sublimated without decomposition. We have used deposition temperatures of the order of 100--200°C in a high vacuum of 10-6--10 -7 Torrs. While some molecules showed a tendency to form polycrystalline films, others led to very high optical quality films, with a roughness of less than 10 nm over tens of micrometers and no grains detected down to a size of 2 nm, as seen in Atomic Force and Scanning Electron Microscopy studies. The best material we developed has a linear refractive index of 1.8 +/- 0.1 at 1.5 mum and an off-resonant third order susceptibility, chi (3), measured through Degenerate Four Wave Mixing, of 2 +/- 1 x 10-19 m2V-2 at 1.5 mum, a value three orders of magnitude larger than fused silica. This vapor deposited thin film may represent one of the best materials demonstrated to date whereby a large third order susceptibility, high optical quality, and simplicity of fabrication and integration are in perfect harmony for integrated nonlinear optical applications. We have used this novel organic material to create a hybrid organic/silicon-on-insulator waveguide that showed a record high nonlinearity coefficient of 10 5 W-1m-1 and has been used as an all-optical switch for demultiplexing a 120 Gbit/s data stream to 10 Gbit/s on a 6 mm long device.

  1. Vapor compression distiller and membrane technology for water revitalization

    NASA Technical Reports Server (NTRS)

    Ashida, A.; Mitani, K.; Ebara, K.; Kurokawa, H.; Sawada, I.; Kashiwagi, H.; Tsuji, T.; Hayashi, S.; Otsubo, K.; Nitta, K.

    1987-01-01

    Water revitalization for a space station can consist of membrane filtration processes and a distillation process. Water recycling equipment using membrane filtration processes was manufactured for ground testing. It was assembled using commercially available components. Two systems for the distillation are studied: one is absorption type thermopervaporation cell and the other is a vapor compression distiller. Absorption type thermopervaporation, able to easily produce condensed water under zero gravity, was investigated experimentally and through simulated calculation. The vapor compression distiller was studied experimentally and it offers significant energy savings for evaporation of water.

  2. Vapor compression distiller and membrane technology for water revitalization.

    PubMed

    Ashida, A; Mitani, K; Ebara, K; Kurokawa, H; Sawada, I; Kashiwagi, H; Tsuji, T; Hayashi, S; Otsubo, K; Nitta, K

    1987-01-01

    Water revitalization for a space station can consist of membrane filtration processes and a distillation process. Water recycling equipment using membrane filtration processes was manufactured for ground testing. It was assembled using commercially available components. Two systems for the distillation are studied; one is an absorption type thermopervaporation cell and the other is a vapor compression distiller. Absorption type thermopervaporation able to easily produce condensed water under zero gravity was investigated experimentally and through simulated calculation. The vapor compression distiller was studied experimentally and it offers significant energy savings for evaporation of water.

  3. Synergistic Interactions Between Direct and Indirect Bypasses in Combined Procedures: The Significance of Indirect Bypasses in Moyamoya Disease.

    PubMed

    Uchino, Haruto; Kim, Jae-Hoon; Fujima, Noriyuki; Kazumata, Ken; Ito, Masaki; Nakayama, Naoki; Kuroda, Satoshi; Houkin, Kiyohiro

    2017-02-01

    Whether additional indirect bypasses effectively contribute to revascularization in combined procedures remains unclear in patients with moyamoya disease. To evaluate the longitudinal changes associated with combined procedures while following up pediatric and adult patients long term and to assess whether any other clinical factors or hemodynamic parameters affected these changes to determine an optimal surgical strategy. We studied 58 hemispheres in 43 adults and 39 hemispheres in 26 children who underwent combined revascularization for moyamoya disease. To evaluate bypass development, we assessed the sizes of the superficial temporal artery and middle meningeal artery using magnetic resonance angiography. Multivariate analysis determined the effects of multiple variables on bypass development. Indirect bypass (middle meningeal artery) development occurred in 95% and 78% of the pediatric and adult hemispheres, respectively. Of these, dual development of direct and indirect bypasses occurred in 54% of the pediatric hemispheres and in 47% of the adult hemispheres. Reciprocal superficial temporal artery regression occurred in 28% of the hemispheres during the transition from the postoperative acute phase to the chronic phase during indirect bypass development. Good indirect bypass development was associated with adult hemispheres at Suzuki stage 4 or greater (odds ratio, 7.4; 95% confidence interval, 1.4-39.4; P = .02). Disease onset type and preoperative hemodynamic parameters were not considered predictors for the development of surgical revascularization. Simultaneous direct and indirect bypass development was most frequently observed, regardless of patient age and hemodynamic status. Applying indirect bypass as an adjunct to direct bypass could maximize revascularization in adults and children.

  4. Scalable Production Method for Graphene Oxide Water Vapor Separation Membranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fifield, Leonard S.; Shin, Yongsoon; Liu, Wei

    ABSTRACT Membranes for selective water vapor separation were assembled from graphene oxide suspension using techniques compatible with high volume industrial production. The large-diameter graphene oxide flake suspensions were synthesized from graphite materials via relatively efficient chemical oxidation steps with attention paid to maintaining flake size and achieving high graphene oxide concentrations. Graphene oxide membranes produced using scalable casting methods exhibited water vapor flux and water/nitrogen selectivity performance meeting or exceeding that of membranes produced using vacuum-assisted laboratory techniques. (PNNL-SA-117497)

  5. [Pedal bypass using venous allograft].

    PubMed

    Pluháčková, H; Staffa, R; Konečný, Z; Kříž, Z; Vlachovský, R

    Pedal or distal crural bypass surgery for limb salvage is a method with very good long-term results. For patients in whom a suitable autologous venous graft is not available, the use of a venous allograft is an alternative procedure. A 68 years old man with ischaemic disease of lower extremities and gangrene of the left foot was admitted to our Centre in August 2014. He underwent percutaneous transluminal angioplasty of crural arteries of his left lower extremity. This, however, failed to improve peripheral circulation. The patient was then indicated for pedal or distal crural vascular reconstruction. Since no suitable autologous vein was available, distal bypass surgery using a donor graft remained the only option for limb salvage. Amputation of the toes on the left foot due to gangrene was necessary. Subsequently, femoro-pedal bypass to the left common plantar artery was performed using a great saphenous vein allograft. The post-operative course was without complications, the pedal bypass was patent and toe amputation was with good healing. The patient remained in follow-up care. A good outcome of vascular reconstruction with an allograft depends on the availability of a suitable allograft and good patient compliance with post-operative care. In the case presented here, the pedal bypass grafting by means of an allograft helped to save the patients limb. pedal bypass venous allograft limb salvage.

  6. [Simplified laparoscopic gastric bypass. Initial experience].

    PubMed

    Hernández-Miguelena, Luis; Maldonado-Vázquez, Angélica; Cortes-Romano, Pablo; Ríos-Cruz, Daniel; Marín-Domínguez, Raúl; Castillo-González, Armando

    2014-01-01

    Obesity surgery includes various gastrointestinal procedures. Roux-en-Y gastric bypass is the prototype of mixed procedures being the most practiced worldwide. A similar and novel technique has been adopted by Dr. Almino Cardoso Ramos and Dr. Manoel Galvao called "simplified bypass," which has been accepted due to the greater ease and very similar results to the conventional technique. The aim of this study is to describe the results of the simplified gastric bypass for treatment of morbid obesity in our institution. We performed a descriptive, retrospective study of all patients undergoing simplified gastric bypass from January 2008 to July 2012 in the obesity clinic of a private hospital in Mexico City. A total of 90 patients diagnosed with morbid obesity underwent simplified gastric bypass. Complications occurred in 10% of patients; these were more frequent bleeding and internal hernia. Mortality in the study period was 0%. The average weight loss at 12 months was 72.7%. Simplified gastric bypass surgery is safe with good mid-term results and a loss of adequate weight in 71% of cases.

  7. 21 CFR 870.4390 - Cardiopulmonary bypass pump tubing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass pump tubing. 870.4390... bypass pump tubing. (a) Identification. A cardiopulmonary bypass pump tubing is polymeric tubing which is... through the cardiopulmonary bypass circuit. (b) Classification. Class II (performance standards). ...

  8. 21 CFR 870.4390 - Cardiopulmonary bypass pump tubing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass pump tubing. 870.4390... bypass pump tubing. (a) Identification. A cardiopulmonary bypass pump tubing is polymeric tubing which is... through the cardiopulmonary bypass circuit. (b) Classification. Class II (performance standards). ...

  9. End plate assembly having a two-phase fluid-filled bladder and method for compressing a fuel cell stack

    DOEpatents

    Carlstrom, Jr., Charles M.

    2001-01-01

    An end plate assembly is disclosed for use in a fuel cell assembly in which the end plate assembly includes a housing having a cavity, and a bladder receivable in the cavity and engageable with the fuel cell stack. The bladder includes a two-phase fluid having a liquid portion and a vapor portion. Desirably, the two-phase fluid has a vapor pressure between about 100 psi and about 600 psi at a temperature between about 70 degrees C. to about 110 degrees C.

  10. Bypass Surgery after Endovascular Therapy for Infrapopliteal Lesion Is Not a Poor Outcome Compared with Initial Bypass Surgery by Vascular Surgeons.

    PubMed

    Morisaki, Koichi; Yamaoka, Terutoshi; Iwasa, Kazuomi; Ohmine, Takahiro

    2017-11-01

    It is unclear whether prior endovascular therapy (EVT) adversely affects bypass surgery. The aim of this study is to investigate treatment outcomes between initial bypass (bypass-first) and bypass surgery after EVT (EVT-first). We conducted a retrospective analysis of critical limb ischemia patients undergoing infrapopliteal bypass between November 2006 and December 2015. Graft patency, limb salvage (LS), amputation-free survival (AFS), and overall survival (OS) were examined between bypass-first and EVT-first groups. The subjects in this study were 75 patients and 82 limbs in the bypass-first group and 24 patients and 24 limbs in the EVT-first group. The average age was higher in EVT-first group (P = 0.03). The percentage of inframalleolar bypass was higher in the EVT-first group (P = 0.002). Primary patency at 1 and 2 years was 72.0% and 67.5% for the bypass-first group and 53.1% and 47.2% for the EVT-first group, respectively (P = 0.04). Inframalleolar bypass was a risk factor for lower primary patency (hazard ratio 3.07, 95% confidence interval 1.18-8.51, P = 0.02) in multivariate analysis, while there were no differences in secondary patency, LS, AFS, and OS. Bypass surgery after EVT has lower primary patency rates in comparison with primary bypass in patients submitted to infrapopliteal revascularization. Although very heterogeneous study population with a lot of bias in the indication of the revascularization, LS, OS and AFS are not affected by previous EVT. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. 21 CFR 870.4400 - Cardiopulmonary bypass blood reservoir.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass blood reservoir. 870.4400... bypass blood reservoir. (a) Identification. A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass...

  12. 21 CFR 870.4400 - Cardiopulmonary bypass blood reservoir.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass blood reservoir. 870.4400... bypass blood reservoir. (a) Identification. A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass...

  13. 21 CFR 870.4400 - Cardiopulmonary bypass blood reservoir.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass blood reservoir. 870.4400... bypass blood reservoir. (a) Identification. A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass...

  14. 21 CFR 870.4400 - Cardiopulmonary bypass blood reservoir.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass blood reservoir. 870.4400... bypass blood reservoir. (a) Identification. A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass...

  15. 21 CFR 870.4400 - Cardiopulmonary bypass blood reservoir.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass blood reservoir. 870.4400... bypass blood reservoir. (a) Identification. A cardiopulmonary bypass blood reservoir is a device used in conjunction with short-term extracorporeal circulation devices to hold a reserve supply of blood in the bypass...

  16. Gastric bypass reduces fat intake and preference

    PubMed Central

    Bueter, Marco; Theis, Nadine; Werling, Malin; Ashrafian, Hutan; Löwenstein, Christian; Athanasiou, Thanos; Bloom, Stephen R.; Spector, Alan C.; Olbers, Torsten; Lutz, Thomas A.

    2011-01-01

    Roux-en-Y gastric bypass is the most effective therapy for morbid obesity. This study investigated how gastric bypass affects intake of and preference for high-fat food in an experimental (rat) study and within a trial setting (human). Proportion of dietary fat in gastric bypass patients was significantly lower 6 yr after surgery compared with patients after vertical-banded gastroplasty (P = 0.046). Gastric bypass reduced total fat and caloric intake (P < 0.001) and increased standard low-fat chow consumption compared with sham controls (P < 0.001) in rats. Compared with sham-operated rats, gastric bypass rats displayed much lower preferences for Intralipid concentrations > 0.5% in an ascending concentration series (0.005%, 0.01%, 0.05%, 0.1%, 0.5%, 1%, 5%) of two-bottle preference tests (P = 0.005). This effect was demonstrated 10 and 200 days after surgery. However, there was no difference in appetitive or consummatory behavior in the brief access test between the two groups (P = 0.71) using similar Intralipid concentrations (0.005% through 5%). Levels of glucagon-like peptide-1 (GLP-1) were increased after gastric bypass as expected. An oral gavage of 1 ml corn oil after saccharin ingestion in gastric bypass rats induced a conditioned taste aversion. These findings suggest that changes in fat preference may contribute to long-term maintained weight loss after gastric bypass. Postingestive effects of high-fat nutrients resulting in conditioned taste aversion may partially explain this observation; the role of GLP-1 in mediating postprandial responses after gastric bypass requires further investigation. PMID:21734019

  17. Gastric bypass reduces fat intake and preference.

    PubMed

    le Roux, Carel W; Bueter, Marco; Theis, Nadine; Werling, Malin; Ashrafian, Hutan; Löwenstein, Christian; Athanasiou, Thanos; Bloom, Stephen R; Spector, Alan C; Olbers, Torsten; Lutz, Thomas A

    2011-10-01

    Roux-en-Y gastric bypass is the most effective therapy for morbid obesity. This study investigated how gastric bypass affects intake of and preference for high-fat food in an experimental (rat) study and within a trial setting (human). Proportion of dietary fat in gastric bypass patients was significantly lower 6 yr after surgery compared with patients after vertical-banded gastroplasty (P = 0.046). Gastric bypass reduced total fat and caloric intake (P < 0.001) and increased standard low-fat chow consumption compared with sham controls (P < 0.001) in rats. Compared with sham-operated rats, gastric bypass rats displayed much lower preferences for Intralipid concentrations > 0.5% in an ascending concentration series (0.005%, 0.01%, 0.05%, 0.1%, 0.5%, 1%, 5%) of two-bottle preference tests (P = 0.005). This effect was demonstrated 10 and 200 days after surgery. However, there was no difference in appetitive or consummatory behavior in the brief access test between the two groups (P = 0.71) using similar Intralipid concentrations (0.005% through 5%). Levels of glucagon-like peptide-1 (GLP-1) were increased after gastric bypass as expected. An oral gavage of 1 ml corn oil after saccharin ingestion in gastric bypass rats induced a conditioned taste aversion. These findings suggest that changes in fat preference may contribute to long-term maintained weight loss after gastric bypass. Postingestive effects of high-fat nutrients resulting in conditioned taste aversion may partially explain this observation; the role of GLP-1 in mediating postprandial responses after gastric bypass requires further investigation.

  18. Solvothermal Vapor Annealing of Lamellar Poly(styrene)-block-poly(d,l-lactide) Block Copolymer Thin Films for Directed Self-Assembly Application.

    PubMed

    Cummins, Cian; Mokarian-Tabari, Parvaneh; Andreazza, Pascal; Sinturel, Christophe; Morris, Michael A

    2016-03-01

    Solvothermal vapor annealing (STVA) was employed to induce microphase separation in a lamellar forming block copolymer (BCP) thin film containing a readily degradable block. Directed self-assembly of poly(styrene)-block-poly(d,l-lactide) (PS-b-PLA) BCP films using topographically patterned silicon nitride was demonstrated with alignment over macroscopic areas. Interestingly, we observed lamellar patterns aligned parallel as well as perpendicular (perpendicular microdomains to substrate in both cases) to the topography of the graphoepitaxial guiding patterns. PS-b-PLA BCP microphase separated with a high degree of order in an atmosphere of tetrahydrofuran (THF) at an elevated vapor pressure (at approximately 40-60 °C). Grazing incidence small-angle X-ray scattering (GISAXS) measurements of PS-b-PLA films reveal the through-film uniformity of perpendicular microdomains after STVA. Perpendicular lamellar orientation was observed on both hydrophilic and relatively hydrophobic surfaces with a domain spacing (L0) of ∼32.5 nm. The rapid removal of the PLA microdomains is demonstrated using a mild basic solution for the development of a well-defined PS mask template. GISAXS data reveal the through-film uniformity is retained following wet etching. The experimental results in this article demonstrate highly oriented PS-b-PLA microdomains after a short annealing period and facile PLA removal to form porous on-chip etch masks for nanolithography application.

  19. Exhaust gas bypass valve control for thermoelectric generator

    DOEpatents

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  20. Ammonia gas sensors based on chemically reduced graphene oxide sheets self-assembled on Au electrodes

    PubMed Central

    2014-01-01

    We present a useful ammonia gas sensor based on chemically reduced graphene oxide (rGO) sheets by self-assembly technique to create conductive networks between parallel Au electrodes. Negative graphene oxide (GO) sheets with large sizes (>10 μm) can be easily electrostatically attracted onto positive Au electrodes modified with cysteamine hydrochloride in aqueous solution. The assembled GO sheets on Au electrodes can be directly reduced into rGO sheets by hydrazine or pyrrole vapor and consequently provide the sensing devices based on self-assembled rGO sheets. Preliminary results, which have been presented on the detection of ammonia (NH3) gas using this facile and scalable fabrication method for practical devices, suggest that pyrrole-vapor-reduced rGO exhibits much better (more than 2.7 times with the concentration of NH3 at 50 ppm) response to NH3 than that of rGO reduced from hydrazine vapor. Furthermore, this novel gas sensor based on rGO reduced from pyrrole shows excellent responsive repeatability to NH3. Overall, the facile electrostatic self-assembly technique in aqueous solution facilitates device fabrication, the resultant self-assembled rGO-based sensing devices, with miniature, low-cost portable characteristics and outstanding sensing performances, which can ensure potential application in gas sensing fields. PMID:24917701

  1. Capacity analysis of a bypass of roundabouts

    NASA Astrophysics Data System (ADS)

    Sedlačik, Ivan; Slabý, Petr

    2017-09-01

    The capacity of the roads network mainly depends on the capacity of its nodal points - intersections. A connecting branch or a bypass is a lane or lanes inserted between two adjacent branches of a roundabout, providing redirection of vehicles, that would otherwise burden a circular lane. A bypass effect to the capacity of roundabouts, but also other types of level intersections, is undeniable. A connecting branch increases the total capacity of an intersection that takes a part of vehicles performing a manoeuver of the first right turn completely out of an intersection area. Redirecting vehicles reduces delay times at intersections and reduces queues at the entrance to an intersection. Bypasses improve the quality of transport. Limiting for the capacity of bypasses is the point of disconnection from the entrance into the roundabout and the connection point into the exit from the roundabout. Central parts of the bypasses have minimal effects on the capacity. The length of a bypass has to match with the maximum length of a queue of waiting vehicles at a given intensity level. The article deals with analysis of the bypass capacity at the roundabouts.

  2. Cardiopulmonary bypass for pediatric cardiac surgery.

    PubMed

    Hirata, Yasutaka

    2018-02-01

    The management of cardiopulmonary bypass for pediatric cardiac surgery is more challenging than that in adults due to the smaller size, immaturity, and complexity of the anatomy in children. Despite major improvements in cardiopulmonary bypass, there remain many subjects of debate. This review article discusses the physiology of cardiopulmonary bypass for pediatric and congenital heart surgery, including topics related to hemodilution, hypothermia, acid-base strategies, inflammatory response, and myocardial protection.

  3. Process development for the manufacture of an integrated dispenser cathode assembly using laser chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Johnson, Ryan William

    2005-07-01

    Laser Chemical Vapor Deposition (LCVD) has been shown to have great potential for the manufacture of small, complex, two or three dimensional metal and ceramic parts. One of the most promising applications of the technology is in the fabrication of an integrated dispenser cathode assembly. This application requires the deposition of a boron nitride-molybdenum composite structure. In order to realize this structure, work was done to improve the control and understanding of the LCVD process and to determine experimental conditions conducive to the growth of the required materials. A series of carbon fiber and line deposition studies were used to characterize process-shape relationships and study the kinetics of carbon LCVD. These studies provided a foundation for the fabrication of the first high aspect ratio multi-layered LCVD wall structures. The kinetics studies enabled the formulation of an advanced computational model in the FLUENT CFD package for studying energy transport, mass and momentum transport, and species transport within a forced flow LCVD environment. The model was applied to two different material systems and used to quantify deposition rates and identify rate-limiting regimes. A computational thermal-structural model was also developed using the ANSYS software package to study the thermal stress state within an LCVD deposit during growth. Georgia Tech's LCVD system was modified and used to characterize both boron nitride and molybdenum deposition independently. The focus was on understanding the relations among process parameters and deposit shape. Boron nitride was deposited using a B3 N3H6-N2 mixture and growth was characterized by sporadic nucleation followed by rapid bulk growth. Molybdenum was deposited from the MoCl5-H2 system and showed slow, but stable growth. Each material was used to grow both fibers and lines. The fabrication of a boron nitride-molybdenum composite was also demonstrated. In sum, this work served to both advance the

  4. Spiritual Bypass: A Preliminary Investigation

    ERIC Educational Resources Information Center

    Cashwell, Craig S.; Glosoff, Harriet L.; Hammond, Cheree

    2010-01-01

    The phenomenon of spiritual bypass has received limited attention in the transpersonal psychology and counseling literature and has not been subjected to empirical inquiry. This study examines the phenomenon of spiritual bypass by considering how spirituality, mindfulness, alexithymia (emotional restrictiveness), and narcissism work together to…

  5. Spill-Resistant Alkali-Metal-Vapor Dispenser

    NASA Technical Reports Server (NTRS)

    Klipstein, William

    2005-01-01

    A spill-resistant vessel has been developed for dispensing an alkali-metal vapor. Vapors of alkali metals (most commonly, cesium or rubidium, both of which melt at temperatures slightly above room temperature) are needed for atomic frequency standards, experiments in spectroscopy, and experiments in laser cooling. Although the present spill-resistant alkali-metal dispenser was originally intended for use in the low-gravity environment of outer space, it can also be used in normal Earth gravitation: indeed, its utility as a vapor source was confirmed by use of cesium in a ground apparatus. The vessel is made of copper. It consists of an assembly of cylinders and flanges, shown in the figure. The uppermost cylinder is a fill tube. Initially, the vessel is evacuated, the alkali metal charge is distilled into the bottom of the vessel, and then the fill tube is pinched closed to form a vacuum seal. The innermost cylinder serves as the outlet for the vapor, yet prevents spilling by protruding above the surface of the alkali metal, no matter which way or how far the vessel is tilted. In the event (unlikely in normal Earth gravitation) that any drops of molten alkali metal have been shaken loose by vibration and are floating freely, a mesh cap on top of the inner cylinder prevents the drops from drifting out with the vapor. Liquid containment of the equivalent of 1.2 grams of cesium was confirmed for all orientations with rubbing alcohol in one of the prototypes later used with cesium.

  6. Novel guanosine-cytidine dinucleoside that self-assembles into a trimeric supramolecule.

    PubMed

    Sessler, Jonathan L; Jayawickramarajah, Janarthanan; Sathiosatham, Muhunthan; Sherman, Courtney L; Brodbelt, Jennifer S

    2003-07-24

    [reaction: see text] Synthesis and assembly studies of a guanosine-cytidine dinucleoside 1 that self-assembles into a trimeric supramolecule (I) are presented. Dinucleoside 1 was obtained by utilizing two consecutive palladium-catalyzed cross-coupling reactions. Ensemble I was analyzed by ESI-MS, NMR spectroscopies, size exclusion chromatography (SEC), and vapor pressure osmometry (VPO).

  7. Life Testing of the Vapor Compression Distillation Urine Processing Assembly (VCD/UPA) at the Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Wieland, Paul O.

    1998-01-01

    Wastewater and urine generated on the International Space Station will be processed to recover pure water. The method selected is vapor compression distillation (VCD). To verify the long-term reliability and performance of the VCD Urine Processing Assembly (UPA), accelerated life testing was performed at the Marshall Space Flight Center (MSFC) from January 1993 to April 1996. Two UPAS, the VCD-5 and VCD-5A, were tested for 204 days and 665 days, respectively. The compressor gears and the distillation centrifuge drive belt were found to have an operating life of approximately 4800 hours. Precise alignment of the flex-spline of the fluids pump is essential to avoid failure of the pump after about 400 hours of operation. Also, leakage around the seals of the drive shaft of the fluids pump and purge pump must be eliminated for continued good performance. Results indicate that, with some design and procedural modifications and suitable quality control, the required performance and operational life can be met with the VCD/UPA.

  8. Re-entrant phase behavior for systems with competition between phase separation and self-assembly

    NASA Astrophysics Data System (ADS)

    Reinhardt, Aleks; Williamson, Alexander J.; Doye, Jonathan P. K.; Carrete, Jesús; Varela, Luis M.; Louis, Ard A.

    2011-03-01

    In patchy particle systems where there is a competition between the self-assembly of finite clusters and liquid-vapor phase separation, re-entrant phase behavior can be observed, with the system passing from a monomeric vapor phase to a region of liquid-vapor phase coexistence and then to a vapor phase of clusters as the temperature is decreased at constant density. Here, we present a classical statistical mechanical approach to the determination of the complete phase diagram of such a system. We model the system as a van der Waals fluid, but one where the monomers can assemble into monodisperse clusters that have no attractive interactions with any of the other species. The resulting phase diagrams show a clear region of re-entrance. However, for the most physically reasonable parameter values of the model, this behavior is restricted to a certain range of density, with phase separation still persisting at high densities.

  9. Diagnostic tools for post-gastric bypass hypoglycaemia.

    PubMed

    Emous, M; Ubels, F L; van Beek, A P

    2015-10-01

    In spite of its evident success, several late complications can occur after gastric bypass surgery. One of these is post-gastric bypass hypoglycaemia. No evidence-based guidelines exist in the literature on how to confirm the presence of this syndrome. This study aims to describe and compare the tests aimed at making a diagnosis of post-gastric bypass hypoglycaemia and to provide a diagnostic approach based upon the available evidence. A search was conducted in PubMed, Cochrane and Embase. A few questionnaires have been developed to measure the severity of symptoms in post-gastric bypass hypoglycaemia but none has been validated. The gold standard for provocation of a hypoglycaemic event is the oral glucose tolerance test or the liquid mixed meal tolerance test. Both show a high prevalence of hypoglycaemia in post-gastric bypass patients with and without hypoglycaemic complaints as well as in healthy volunteers. No uniformly established cut-off values for glucose concentrations are defined in the literature for the diagnosis of post-gastric bypass hypoglycaemia. For establishing an accurate diagnosis of post-gastric bypass hypoglycaemia, a validated questionnaire, in connection with the diagnostic performance of provocation tests, is the most important thing missing. Given these shortcomings, we provide recommendations based upon the current literature. © 2015 World Obesity.

  10. Variable volume combustor with an air bypass system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Thomas Edward; Ziminsky, Willy Steve; Ostebee, Heath Michael

    The present application provides a combustor for use with flow of fuel and a flow of air in a gas turbine engine. The combustor may include a number of micro-mixer fuel nozzles positioned within a liner and an air bypass system position about the liner. The air bypass system variably allows a bypass portion of the flow of air to bypass the micro-mixer fuel nozzles.

  11. 21 CFR 870.4320 - Cardiopulmonary bypass pulsatile flow generator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass pulsatile flow generator... Cardiopulmonary bypass pulsatile flow generator. (a) Identification. A cardiopulmonary bypass pulsatile flow... device is placed in a cardiopulmonary bypass circuit downstream from the oxygenator. (b) Classification...

  12. 21 CFR 870.4420 - Cardiopulmonary bypass cardiotomy return sucker.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass cardiotomy return sucker... Cardiopulmonary bypass cardiotomy return sucker. (a) Identification. A cardiopulmonary bypass cardiotomy return... from the chest or heart during cardiopulmonary bypass surgery. (b) Classification. Class II...

  13. 21 CFR 870.4420 - Cardiopulmonary bypass cardiotomy return sucker.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass cardiotomy return sucker... Cardiopulmonary bypass cardiotomy return sucker. (a) Identification. A cardiopulmonary bypass cardiotomy return... from the chest or heart during cardiopulmonary bypass surgery. (b) Classification. Class II...

  14. 21 CFR 870.4320 - Cardiopulmonary bypass pulsatile flow generator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass pulsatile flow generator... Cardiopulmonary bypass pulsatile flow generator. (a) Identification. A cardiopulmonary bypass pulsatile flow... device is placed in a cardiopulmonary bypass circuit downstream from the oxygenator. (b) Classification...

  15. 40 CFR 403.17 - Bypass.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Definitions. (1) Bypass means the intentional diversion of wastestreams from any portion of an Industrial User... applicable Pretreatment Standards or Requirements. An Industrial User may allow any bypass to occur which... paragraphs (c) and (d) of this section. (c) Notice. (1) If an Industrial User knows in advance of the need...

  16. 40 CFR 403.17 - Bypass.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Definitions. (1) Bypass means the intentional diversion of wastestreams from any portion of an Industrial User... applicable Pretreatment Standards or Requirements. An Industrial User may allow any bypass to occur which... paragraphs (c) and (d) of this section. (c) Notice. (1) If an Industrial User knows in advance of the need...

  17. 40 CFR 403.17 - Bypass.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Definitions. (1) Bypass means the intentional diversion of wastestreams from any portion of an Industrial User... applicable Pretreatment Standards or Requirements. An Industrial User may allow any bypass to occur which... paragraphs (c) and (d) of this section. (c) Notice. (1) If an Industrial User knows in advance of the need...

  18. 40 CFR 403.17 - Bypass.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Definitions. (1) Bypass means the intentional diversion of wastestreams from any portion of an Industrial User... applicable Pretreatment Standards or Requirements. An Industrial User may allow any bypass to occur which... paragraphs (c) and (d) of this section. (c) Notice. (1) If an Industrial User knows in advance of the need...

  19. 40 CFR 403.17 - Bypass.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Definitions. (1) Bypass means the intentional diversion of wastestreams from any portion of an Industrial User... applicable Pretreatment Standards or Requirements. An Industrial User may allow any bypass to occur which... paragraphs (c) and (d) of this section. (c) Notice. (1) If an Industrial User knows in advance of the need...

  20. Bypass apparatus and method for series connected energy storage devices

    DOEpatents

    Rouillard, Jean; Comte, Christophe; Daigle, Dominik

    2000-01-01

    A bypass apparatus and method for series connected energy storage devices. Each of the energy storage devices coupled to a common series connection has an associated bypass unit connected thereto in parallel. A current bypass unit includes a sensor which is coupled in parallel with an associated energy storage device or cell and senses an energy parameter indicative of an energy state of the cell, such as cell voltage. A bypass switch is coupled in parallel with the energy storage cell and operable between a non-activated state and an activated state. The bypass switch, when in the non-activated state, is substantially non-conductive with respect to current passing through the energy storage cell and, when in the activated state, provides a bypass current path for passing current to the series connection so as to bypass the associated cell. A controller controls activation of the bypass switch in response to the voltage of the cell deviating from a pre-established voltage setpoint. The controller may be included within the bypass unit or be disposed on a control platform external to the bypass unit. The bypass switch may, when activated, establish a permanent or a temporary bypass current path.

  1. Brain microvascular function during cardiopulmonary bypass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorensen, H.R.; Husum, B.; Waaben, J.

    1987-11-01

    Emboli in the brain microvasculature may inhibit brain activity during cardiopulmonary bypass. Such hypothetical blockade, if confirmed, may be responsible for the reduction of cerebral metabolic rate for glucose observed in animals subjected to cardiopulmonary bypass. In previous studies of cerebral blood flow during bypass, brain microcirculation was not evaluated. In the present study in animals (pigs), reduction of the number of perfused capillaries was estimated by measurements of the capillary diffusion capacity for hydrophilic tracers of low permeability. Capillary diffusion capacity, cerebral blood flow, and cerebral metabolic rate for glucose were measured simultaneously by the integral method, different tracersmore » being used with different circulation times. In eight animals subjected to normothermic cardiopulmonary bypass, and seven subjected to hypothermic bypass, cerebral blood flow, cerebral metabolic rate for glucose, and capillary diffusion capacity decreased significantly: cerebral blood flow from 63 to 43 ml/100 gm/min in normothermia and to 34 ml/100 gm/min in hypothermia and cerebral metabolic rate for glucose from 43.0 to 23.0 mumol/100 gm/min in normothermia and to 14.1 mumol/100 gm/min in hypothermia. The capillary diffusion capacity declined markedly from 0.15 to 0.03 ml/100 gm/min in normothermia but only to 0.08 ml/100 gm/min in hypothermia. We conclude that the decrease of cerebral metabolic rate for glucose during normothermic cardiopulmonary bypass is caused by interruption of blood flow through a part of the capillary bed, possibly by microemboli, and that cerebral blood flow is an inadequate indicator of capillary blood flow. Further studies must clarify why normal microvascular function appears to be preserved during hypothermic cardiopulmonary bypass.« less

  2. Femoropopliteal Bypass with Varicose Greater Saphenous Vein

    PubMed Central

    Mun, Yun Su; Cho, Byung Sun; Jang, Je-Ho; Lee, Moon-Soo; Kwon, Oh Sang

    2015-01-01

    Surgical bypass for peripheral arterial occlusive disease can be performed using different graft materials. Autogenous greater saphenous vein (GSV) is the treatment of choice because of its superior long-term patency. We report a case of femoropopliteal bypass with varicose GSV in a 77-year-old man who was presented with limb ischemia and both varicose veins. We successfully performed bypass with varicose vein. He has been doing well for 15 months after the operation, and a computed tomography angiography of the lower leg, performed on the 15th postoperative month, demonstrated widely patent femoropopliteal bypass graft and no structural change. PMID:28031670

  3. 21 CFR 870.4310 - Cardiopulmonary bypass coronary pressure gauge.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Cardiopulmonary bypass coronary pressure gauge. (a) Identification. A cardiopulmonary bypass coronary pressure gauge is a device used in cardiopulmonary bypass surgery to measure the pressure of the blood perfusing... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass coronary pressure gauge...

  4. 21 CFR 870.4310 - Cardiopulmonary bypass coronary pressure gauge.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Cardiopulmonary bypass coronary pressure gauge. (a) Identification. A cardiopulmonary bypass coronary pressure gauge is a device used in cardiopulmonary bypass surgery to measure the pressure of the blood perfusing... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass coronary pressure gauge...

  5. 21 CFR 870.4310 - Cardiopulmonary bypass coronary pressure gauge.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Cardiopulmonary bypass coronary pressure gauge. (a) Identification. A cardiopulmonary bypass coronary pressure gauge is a device used in cardiopulmonary bypass surgery to measure the pressure of the blood perfusing... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass coronary pressure gauge...

  6. 21 CFR 870.4310 - Cardiopulmonary bypass coronary pressure gauge.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Cardiopulmonary bypass coronary pressure gauge. (a) Identification. A cardiopulmonary bypass coronary pressure gauge is a device used in cardiopulmonary bypass surgery to measure the pressure of the blood perfusing... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass coronary pressure gauge...

  7. 21 CFR 870.4310 - Cardiopulmonary bypass coronary pressure gauge.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Cardiopulmonary bypass coronary pressure gauge. (a) Identification. A cardiopulmonary bypass coronary pressure gauge is a device used in cardiopulmonary bypass surgery to measure the pressure of the blood perfusing... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass coronary pressure gauge...

  8. 21 CFR 870.4380 - Cardiopulmonary bypass pump speed control.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass pump speed control. 870... Cardiopulmonary bypass pump speed control. (a) Identification. A cardiopulmonary bypass pump speed control is a... control the speed of blood pumps used in cardiopulmonary bypass surgery. (b) Classification. Class II...

  9. 21 CFR 870.4380 - Cardiopulmonary bypass pump speed control.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass pump speed control. 870... Cardiopulmonary bypass pump speed control. (a) Identification. A cardiopulmonary bypass pump speed control is a... control the speed of blood pumps used in cardiopulmonary bypass surgery. (b) Classification. Class II...

  10. Moisture Durability with Vapor-Permeable Insulating Sheathing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepage, R.; Lstiburek, J.

    2013-09-01

    Exterior sheathing insulation is an effective strategy in increasing the overall R-value of wall assemblies; other benefits include decreasing the effects of thermal bridging and increasing the moisture durability of the built assembly. Vapor-permeable exterior insulation, such as mineral board or expanded polystyrene foam, are one such product that may be used to achieve these benefits. However,uncertainty exists on the effects of inward driven moisture and the interaction of increased sheathing temperatures on the moisture durability of the edifice. To address these concerns, Building Science Corporation (BSC) conducted a series of hygrothermal models for cities representing a range of differentmore » climate zones. This report describes the research project, key research questions, and theprocedures utilized to analyse the problems.« less

  11. Moisture Durability with Vapor-Permeable Insulating Sheathing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepage, R.; Lstiburek, J.

    2013-09-01

    Exterior sheathing insulation is an effective strategy in increasing the overall R-value of wall assemblies; other benefits include decreasing the effects of thermal bridging and increasing the moisture durability of the built assembly. Vapor-permeable exterior insulation, such as mineral board or expanded polystyrene foam, are one such product that may be used to achieve these benefits. However, uncertainty exists on the effects of inward driven moisture and the interaction of increased sheathing temperatures on the moisture durability of the edifice. To address these concerns, Building Science Corporation (BSC) conducted a series of hygrothermal models for cities representing a range ofmore » different climate zones. This report describes the research project, key research questions, and the procedures utilized to analyse the problems.« less

  12. Prolonged partial cardiopulmonary bypass in rats.

    PubMed

    Alexander, B; Al Ani, H R

    1983-07-01

    Membrane oxygenators have been shown to be atraumatic during cardiopulmonary bypass. A novel design for a membrane tubing oxygenator originated in this laboratory was used for prolonged partial supportive cardiopulmonary bypass in lambs and displayed excellent biocompatability characteristics. This was miniaturized, to result in a prime volume of 12 ml, in order to investigate the feasibility of prolonged partial supportive cardiopulmonary bypass in rats. The performance of this miniaturized circuit over perfusion periods up to 6 hr is described, with particular reference to hematological changes.

  13. DNA-Assembled Advanced Plasmonic Architectures.

    PubMed

    Liu, Na; Liedl, Tim

    2018-03-28

    The interaction between light and matter can be controlled efficiently by structuring materials at a length scale shorter than the wavelength of interest. With the goal to build optical devices that operate at the nanoscale, plasmonics has established itself as a discipline, where near-field effects of electromagnetic waves created in the vicinity of metallic surfaces can give rise to a variety of novel phenomena and fascinating applications. As research on plasmonics has emerged from the optics and solid-state communities, most laboratories employ top-down lithography to implement their nanophotonic designs. In this review, we discuss the recent, successful efforts of employing self-assembled DNA nanostructures as scaffolds for creating advanced plasmonic architectures. DNA self-assembly exploits the base-pairing specificity of nucleic acid sequences and allows for the nanometer-precise organization of organic molecules but also for the arrangement of inorganic particles in space. Bottom-up self-assembly thus bypasses many of the limitations of conventional fabrication methods. As a consequence, powerful tools such as DNA origami have pushed the boundaries of nanophotonics and new ways of thinking about plasmonic designs are on the rise.

  14. Volatile anaesthesia during cardiopulmonary bypass.

    PubMed

    McMullan, V; Alston, R P; Tyrrell, J

    2015-01-01

    Since its inception, administering and ensuring anaesthesia during cardiopulmonary bypass has been challenging. Partly because of the difficulty of administering volatile agents during cardiopulmonary bypass, total intravenous anaesthesia has been a popular technique used by cardiac anaesthetists in the last two decades. However, the possibility that volatile agents reduce mortality and the incidence of myocardial infarction by preconditioning the myocardium has stimulated a resurgence of interest in their use for cardiac anaesthesia. The aim of this review is to provide an overview of the administration of volatile anaesthetic agents during cardiopulmonary bypass for the maintenance of anaesthesia and to address some of the practical issues that are involved in doing so. © The Author(s) 2014.

  15. Direct Bypass Versus Indirect Bypass in Adult Moyamoya Angiopathy with Symptoms or Hemodynamic Instability: A Meta-analysis of Comparative Studies.

    PubMed

    Kim, Hoon; Jang, Dong-Kyu; Han, Young-Min; Sung, Jae Hoon; Park, Ik Seong; Lee, Kwan-Sung; Yang, Ji-Ho; Huh, Pil Woo; Park, Young Sup; Kim, Dal-Soo; Han, Kyung-Do

    2016-10-01

    It remains controversial which bypass methods are optimal for treating adult moyamoya angiopathy patients. This study aimed to analyze the literature about whether different bypass methods affect differently outcome results of adult moyamoya patients with symptoms or hemodynamic instability. A systematic search of the PubMed, Embase, and Cochrane Central databases was performed for articles published between 1990 and 2015. Comparative studies about the effect of direct or combined bypass (direct bypass group) and indirect bypass (indirect bypass group) in patients with moyamoya angiopathy at 18 years of age or older were selected. For stroke incidence at the end of the follow-up period, the degree of angiographic revascularization, hemodynamic improvement, and perioperative complication rates within 30 days, pooled relative risks were calculated between the 2 groups with a 95% confidence interval. A total of 8 articles (including 536 patients and 732 treated hemispheres) were included in the meta-analysis. There were no significant differences between the 2 groups when we compared the overall stroke rate, the hemodynamic improvement rate, or the perioperative complication rate at the end of the follow-up period. The direct bypass group, however, had a lower risk than the indirect bypass group for obtaining a poor angiographic revascularization rate (risk ratio, 0.35; 95% confidence interval, 0.15-0.84; P = 0.02). The current meta-analysis suggests that the direct or combined bypass surgical method is better for angiographic revascularization in adult moyamoya patients with symptoms or hemodynamic instability. Future studies may be necessary to confirm these findings. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. 21 CFR 870.4250 - Cardiopulmonary bypass temperature controller.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass temperature controller. 870.4250 Section 870.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Cardiopulmonary bypass temperature controller. (a) Identification. A cardiopulmonary bypass temperature controller...

  17. 21 CFR 870.4250 - Cardiopulmonary bypass temperature controller.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass temperature controller. 870.4250 Section 870.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Cardiopulmonary bypass temperature controller. (a) Identification. A cardiopulmonary bypass temperature controller...

  18. Research Update: A minimal region of squid reflectin for vapor-induced light scattering

    NASA Astrophysics Data System (ADS)

    Dennis, Patrick B.; Singh, Kristi M.; Vasudev, Milana C.; Naik, Rajesh R.; Crookes-Goodson, Wendy J.

    2017-12-01

    Reflectins are a family of proteins found in the light manipulating cells of cephalopods. These proteins are made up of a series of conserved repeats that contain highly represented amino acids thought to be important for function. Previous studies demonstrated that recombinant reflectins cast into thin films produced structural colors that could be dynamically modulated via changing environmental conditions. In this study, we demonstrate light scattering from reflectin films following exposure to a series of water vapor pulses. Analysis of film surface topography shows that the induction of light scatter is accompanied by self-assembly of reflectins into micro- and nanoscale features. Using a reductionist strategy, we determine which reflectin repeats and sub-repeats are necessary for these events following water vapor pulsing. With this approach, we identify a singly represented, 23-amino acid region in reflectins as being sufficient to recapitulate the light scattering properties observed in thin films of the full-length protein. Finally, the aqueous stability of reflectin films is leveraged to show that pre-exposure to buffers of varying pH can modulate the ability of water vapor pulses to induce light scatter and protein self-assembly.

  19. Assembly and intracellular delivery of quantum dot-fluorescent protein bioconjugates

    NASA Astrophysics Data System (ADS)

    Medintz, Igor L.; Pons, Thomas; Delehanty, James B.; Susumu, Kimihiro; Dawson, Philip E.; Mattoussi, Hedi

    2008-02-01

    We have previously assembled semiconductor quantum dot (QD)-based fluorescence resonance energy transfer (FRET) sensors that can specifically detect nutrients, explosives or enzymatic activity. These sensors utilized the inherent benefits of QDs as FRET donors to optimize signal transduction. In this report we functionalize QDs with the multi-subunit multi-chromophore b-phycoerythrin (b-PE) light harvesting complex using biotin-Streptavidin binding. FRET and gel electrophoretic analyses were used to characterize and confirm the QD-b-PE self-assembly. We found that immobilizing additional cell-penetrating peptides on the nanocrystal surface along with the b-PE was the key factor allowing the mixed surface QD-cargos to undergo endocytosis and intracellular delivery. Our findings on the intracellular uptake promoted by CPP were compared to those collected using microinjection technique, where QD-assemblies were delivered directly into the cytoplasm; this strategy allows bypassing of the endocytic uptake pathway. Intracellular delivery of multifunctional QD-fluorescent protein assemblies has potential applications for use in protein tracking, sensing and diagnostics.

  20. Long-term patency of superficial temporal artery to middle cerebral artery bypass for cerebral atherosclerotic disease: factors determining the bypass patent.

    PubMed

    Matano, Fumihiro; Murai, Yasuo; Tateyama, Kojiro; Tamaki, Tomonori; Mizunari, Takayuki; Matsukawa, Hideoshi; Teramoto, Akira; Morita, Akio

    2016-10-01

    Long-term patency of superficial temporal artery to middle cerebral artery (STA-MCA) bypass surgery for atherosclerotic disease and associated risk factors for loss of patency have rarely been discussed. We retrospectively analyzed long-term patency following STA-MCA bypass and evaluated various demographic and clinical factors to identify the ones predictive of postsurgical loss of patency using records of 84 revascularization procedures (58 patients, 45 males; mean age at surgery 63.6 years, range 31-78 years). Bypass patency was diagnosed based on magnetic resonance angiography or three-dimensional computed tomography. The mean follow-up period was 24.7 months (range 6-63 months). Decreased bypass patency was observed in 4 of 58 patients (6.9 %) who collectively underwent 6 bypasses (7.1 %) of 84. All cases of decreased bypass patency were first detected within 6 months of surgery. Bypass patency was not correlated with age, sex, number of anastomoses, postoperative cerebral infarction, or control of postoperative diabetes mellitus. We found a significant association of bypass patency with hyperperfusion (p = 0.01) and postoperative smoking (p = 0.0036). Furthermore, we found a significant association of hyperperfusion with STA diameter (p < 0.0001), location of anastomosis (p = 0.075), and preoperative cerebral blood flow (p = 0.0399). In our retrospective study, hyperperfusion and smoking after surgery may be risk factors for decreased bypass patency in cerebral atherosclerotic disease patients. Careful monitoring of patency to prevent hyperperfusion and cessation of smoking are recommended, particularly within 6 months of the surgery.

  1. Occipital-posterior cerebral artery bypass via the occipital interhemispheric approach

    PubMed Central

    Kazumata, Ken; Yokoyama, Yuka; Sugiyama, Taku; Asaoka, Katsuyuki

    2013-01-01

    Background: The unavailability of the superficial temporal artery (STA) and the location of lesions pose a more technically demanding challenge when compared with conventional STA-superior cerebellar or posterior cerebral artery (PCA) bypass in vascular reconstruction procedures. To describe a case series of patients with cerebrovascular lesions who were treated using an occipital artery (OA) to PCA bypass via the occipital interhemispheric approach. Methods: We retrospectively reviewed three consecutive cases of patients with cerebrovascular lesions who were treated using OA-PCA bypass. Results: OA-PCA bypass was performed via the occipital interhemispheric approach. This procedure included: (1) OA-PCA bypass (n = 1), and combined OA-posterior inferior cerebellar artery and OA-PCA saphenous vein interposition graft bypass (n = 1) in patients with vertebrobasilar ischemia; (2) OA-PCA radial artery interposition graft bypass in one patient with residual PCA aneurysm. Conclusions: OA-PCA bypass represents a useful alternative to conventional STA-SCA or PCA bypass. PMID:23956933

  2. 21 CFR 870.4250 - Cardiopulmonary bypass temperature controller.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass temperature controller. 870... Cardiopulmonary bypass temperature controller. (a) Identification. A cardiopulmonary bypass temperature controller is a device used to control the temperature of the fluid entering and leaving a heat exchanger. (b...

  3. 21 CFR 870.4250 - Cardiopulmonary bypass temperature controller.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass temperature controller. 870... Cardiopulmonary bypass temperature controller. (a) Identification. A cardiopulmonary bypass temperature controller is a device used to control the temperature of the fluid entering and leaving a heat exchanger. (b...

  4. 21 CFR 870.4250 - Cardiopulmonary bypass temperature controller.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass temperature controller. 870... Cardiopulmonary bypass temperature controller. (a) Identification. A cardiopulmonary bypass temperature controller is a device used to control the temperature of the fluid entering and leaving a heat exchanger. (b...

  5. 21 CFR 870.4240 - Cardiopulmonary bypass heat exchanger.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass heat exchanger. 870.4240... bypass heat exchanger. (a) Identification. A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or...

  6. 21 CFR 870.4240 - Cardiopulmonary bypass heat exchanger.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass heat exchanger. 870.4240... bypass heat exchanger. (a) Identification. A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or...

  7. 21 CFR 870.4205 - Cardiopulmonary bypass bubble detector.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass bubble detector. 870.4205 Section 870.4205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... bypass bubble detector. (a) Identification. A cardiopulmonary bypass bubble detector is a device used to...

  8. 21 CFR 870.4205 - Cardiopulmonary bypass bubble detector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass bubble detector. 870.4205 Section 870.4205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... bypass bubble detector. (a) Identification. A cardiopulmonary bypass bubble detector is a device used to...

  9. 21 CFR 870.4205 - Cardiopulmonary bypass bubble detector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass bubble detector. 870.4205 Section 870.4205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... bypass bubble detector. (a) Identification. A cardiopulmonary bypass bubble detector is a device used to...

  10. 21 CFR 870.4205 - Cardiopulmonary bypass bubble detector.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass bubble detector. 870.4205 Section 870.4205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... bypass bubble detector. (a) Identification. A cardiopulmonary bypass bubble detector is a device used to...

  11. 21 CFR 870.4205 - Cardiopulmonary bypass bubble detector.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass bubble detector. 870.4205 Section 870.4205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... bypass bubble detector. (a) Identification. A cardiopulmonary bypass bubble detector is a device used to...

  12. 21 CFR 870.4240 - Cardiopulmonary bypass heat exchanger.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass heat exchanger. 870.4240... bypass heat exchanger. (a) Identification. A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or...

  13. 21 CFR 870.4240 - Cardiopulmonary bypass heat exchanger.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass heat exchanger. 870.4240... bypass heat exchanger. (a) Identification. A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or...

  14. 21 CFR 870.4240 - Cardiopulmonary bypass heat exchanger.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass heat exchanger. 870.4240... bypass heat exchanger. (a) Identification. A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or...

  15. Bypass transition to turbulence and research Desiderata

    NASA Technical Reports Server (NTRS)

    Morkovin, M. V.

    1985-01-01

    Bypass transitions are seldom mentioned in texts or meetings on instability and transition to wall turbulence. The nature of a number of bypass transitions is illustrated by example. Until this characteristics is truly understood predicting transition on the basis of theory or statistically inadequate correlations (as they all are) entails risks that should be considered in justifying any design involving transition. A historical overview of bypass transition identified on blunt bodies is given.

  16. Vapor characterization of Tank 241-C-103

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huckaby, J.L.; Story, M.S.

    The Westinghouse Hanford Company Tank Vapor Issue Resolution Program has developed, in cooperation with Northwest Instrument Systems, Inc., Oak Ridge National Laboratory, Oregon Graduate Institute of Science and Technology, Pacific Northwest Laboratory, and Sandia National Laboratory, the equipment and expertise to characterize gases and vapors in the high-level radioactive waste storage tanks at the Hanford Site in south central Washington State. This capability has been demonstrated by the characterization of the tank 241-C-103 headspace. This tank headspace is the first, and for many reasons is expected to be the most problematic, that will be characterized (Osborne 1992). Results from themore » most recent and comprehensive sampling event, sample job 7B, are presented for the purpose of providing scientific bases for resolution of vapor issues associated with tank 241-C-103. This report is based on the work of Clauss et al. 1994, Jenkins et al. 1994, Ligotke et al. 1994, Mahon et al. 1994, and Rasmussen and Einfeld 1994. No attempt has been made in this report to evaluate the implications of the data presented, such as the potential impact of headspace gases and vapors to tank farm workers health. That and other issues will be addressed elsewhere. Key to the resolution of worker health issues is the quantitation of compounds of toxicological concern. The Toxicology Review Panel, a panel of Pacific Northwest Laboratory experts in various areas, of toxicology, has chosen 19 previously identified compounds as being of potential toxicological concern. During sample job 7B, the sampling and analytical methodology was validated for this preliminary list of compounds of toxicological concern. Validation was performed according to guidance provided by the Tank Vapor Conference Committee, a group of analytical chemists from academic institutions and national laboratories assembled and commissioned by the Tank Vapor Issue Resolution Program.« less

  17. Battery Cell By-Pass Circuit

    NASA Technical Reports Server (NTRS)

    Mumaw, Susan J. (Inventor); Evers, Jeffrey (Inventor); Craig, Calvin L., Jr. (Inventor); Walker, Stuart D. (Inventor)

    2001-01-01

    The invention is a circuit and method of limiting the charging current voltage from a power supply net work applied to an individual cell of a plurality of cells making up a battery being charged in series. It is particularly designed for use with batteries that can be damaged by overcharging, such as Lithium-ion type batteries. In detail. the method includes the following steps: 1) sensing the actual voltage level of the individual cell; 2) comparing the actual voltage level of the individual cell with a reference value and providing an error signal representative thereof; and 3) by-passing the charging current around individual cell necessary to keep the individual cell voltage level generally equal a specific voltage level while continuing to charge the remaining cells. Preferably this is accomplished by by-passing the charging current around the individual cell if said actual voltage level is above the specific voltage level and allowing the charging current to the individual cell if the actual voltage level is equal or less than the specific voltage level. In the step of bypassing the charging current, the by-passed current is transferred at a proper voltage level to the power supply. The by-pass circuit a voltage comparison circuit is used to compare the actual voltage level of the individual cell with a reference value and to provide an error signal representative thereof. A third circuit, designed to be responsive to the error signal, is provided for maintaining the individual cell voltage level generally equal to the specific voltage level. Circuitry is provided in the third circuit for bypassing charging current around the individual cell if the actual voltage level is above the specific voltage level and transfers the excess charging current to the power supply net work. The circuitry also allows charging of the individual cell if the actual voltage level is equal or less than the specific voltage level.

  18. Surgical outcomes for moyamoya angiopathy at barrow neurological institute with comparison of adult indirect encephaloduroarteriosynangiosis bypass, adult direct superficial temporal artery-to-middle cerebral artery bypass, and pediatric bypass: 154 revascularization surgeries in 140 affected hemispheres.

    PubMed

    Abla, Adib A; Gandhoke, Gurpreet; Clark, Justin C; Oppenlander, Mark E; Velat, Gregory J; Zabramski, Joseph M; Albuquerque, Felipe C; Nakaji, Peter; Spetzler, Robert F; Wanebo, John E

    2013-09-01

    Untreated, moyamoya angiopathy is a progressive vaso-occlusive process that can lead to ischemic or hemorrhagic stroke. To review 1 institution's surgical experience with both direct and indirect bypass (encephaloduroarteriosynangiosis) in adult and pediatric groups. A retrospective review was conducted of a consecutive series of patients treated for moyamoya angiopathy between 1995 and 2009. Thirty-nine adult patients underwent indirect bypass as their initial therapy; 29 adult patients underwent direct bypass. Twenty-four pediatric patients included 20 indirect bypasses and 4 direct bypasses. Overall, 140 hemispheres were treated; 48 patients received revascularization of both hemispheres. There were 14 additional revascularization procedures (10% per hemisphere) performed over a site of continued hypoperfusion postoperatively. Fourteen postoperative ischemic strokes occurred during the entire follow-up (10% per hemisphere), and the Kaplan-Meier analysis was not significantly different between groups (P = .59). Four grafts (9.09%) had failed at radiographic follow-up of the 44 direct bypasses performed. Before the initial surgery, the modified Rankin Scale score was 1.58 ± 0.93, 1.48 ± 0.74, and 1.8 ± 1.1 in the pediatric, adult direct, and adult indirect groups (P = .39). At last follow-up, it was 1.29 ± 1.31, 1.09 ± 0.90, and 1.94 ± 1.51 (P = .04) in the pediatric, adult direct, and adult indirect groups. This series demonstrates that both direct and indirect bypasses can be equally effective in preventing stroke. However, in adult patients, direct bypass patients had significantly greater improvement in symptoms, as seen in modified Rankin Scale scores. Pediatric patients, despite undergoing predominantly indirect bypasses, fared roughly the same as the adults in the direct bypass group.

  19. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  20. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  1. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  2. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  3. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  4. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  5. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  6. 30 CFR 57.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Overtravel by-pass switches. 57.19018 Section... Hoisting Hoists § 57.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  7. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  8. 30 CFR 56.19018 - Overtravel by-pass switches.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Overtravel by-pass switches. 56.19018 Section... Hoisting Hoists § 56.19018 Overtravel by-pass switches. When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the...

  9. Long-term Effects of Off-Pump Coronary Bypass Versus Conventional Coronary Bypass Grafting on Renal Function.

    PubMed

    Hynes, Conor F; Colo, Sanchez; Amdur, Richard L; Chawla, Lakhmir S; Greenberg, Michael D; Trachiotis, Gregory D

    2016-01-01

    This study aimed to evaluate the short- and long-term effects of conventional on-pump coronary bypass grafting (cCABG) compared with off-pump coronary artery bypass (OPCAB) on renal function. A retrospective review of patients undergoing coronary bypass grafting from 2004 through 2013 at a single center was conducted. Preoperative renal function, perioperative acute kidney injury, and long-term glomerular filtration were evaluated. Multivariable analyses were used to determine factors contributing to short- and long-term renal impairment. A total of 234 patients underwent cCABG, and 582 underwent OPCAB. Patients undergoing OPCAB were significantly older, had greater preoperative renal dysfunction, had greater functional dependence, and took more hypertension medications. Multivariable analyses found that 30-day acute kidney injury was an independent risk factor for a 10% decline in glomerular filtration rate at 1 and 5 years (P < 0.0001 and 0.002, respectively). However, the use of cardiopulmonary bypass was not found to influence long-term renal function (P = 0.78 at 1 year, P = 0.76 at 5 years). The percentage of patients experiencing a 10% drop in renal function from baseline at 1 year (33% OPCAB, 35% cCABG; P = 0.73) and 5 years (16% OPCAB, 16% cCABG; P = 0.93) were not significantly different. Independent predictors of acute kidney injury included baseline kidney function (P = 0.04) and age (P < 0.0001), whereas cardiopulmonary bypass did not affect the incidence (P = 0.17). A propensity-matched analysis confirmed these findings. Acute kidney injury is a risk factor for long-term renal dysfunction after either bypass method and was not greater after cCABG compared with OPCAB. Patients undergoing OPCAB did not experience greater decrease in long-term kidney function despite having worse baseline kidney function.

  10. Morphogenetic Pathway of Spore Wall Assembly in Saccharomyces cerevisiae

    PubMed Central

    Coluccio, Alison; Bogengruber, Edith; Conrad, Michael N.; Dresser, Michael E.; Briza, Peter; Neiman, Aaron M.

    2004-01-01

    The Saccharomyces cerevisiae spore is protected from environmental damage by a multilaminar extracellular matrix, the spore wall, which is assembled de novo during spore formation. A set of mutants defective in spore wall assembly were identified in a screen for mutations causing sensitivity of spores to ether vapor. The spore wall defects in 10 of these mutants have been characterized in a variety of cytological and biochemical assays. Many of the individual mutants are defective in the assembly of specific layers within the spore wall, leading to arrests at discrete stages of assembly. The localization of several of these gene products has been determined and distinguishes between proteins that likely are involved directly in spore wall assembly and probable regulatory proteins. The results demonstrate that spore wall construction involves a series of dependent steps and provide the outline of a morphogenetic pathway for assembly of a complex extracellular structure. PMID:15590821

  11. Vapor-Liquid-Solid Etch of Semiconductor Surface Channels by Running Gold Nanodroplets.

    PubMed

    Nikoobakht, Babak; Herzing, Andrew; Muramoto, Shin; Tersoff, Jerry

    2015-12-09

    We show that Au nanoparticles spontaneously move across the (001) surface of InP, InAs, and GaP when heated in the presence of water vapor. As they move, the particles etch crystallographically aligned grooves into the surface. We show that this process is a negative analogue of the vapor-liquid-solid (VLS) growth of semiconductor nanowires: the semiconductor dissolves into the catalyst and reacts with water vapor at the catalyst surface to create volatile oxides, depleting the dissolved cations and anions and thus sustaining the dissolution process. This VLS etching process provides a new tool for directed assembly of structures with sublithographic dimensions, as small as a few nanometers in diameter. Au particles above 100 nm in size do not exhibit this process but remain stationary, with oxide accumulating around the particles.

  12. Roux-en-Y gastric bypass operation in rats.

    PubMed

    Bueter, Marco; Abegg, Kathrin; Seyfried, Florian; Lutz, Thomas A; le Roux, Carel W

    2012-06-11

    Currently, the most effective therapy for the treatment of morbid obesity to induce significant and maintained body weight loss with a proven mortality benefit is bariatric surgery. Consequently, there has been a steady rise in the number of bariatric operations done worldwide in recent years with the Roux-en-Y gastric bypass (gastric bypass) being the most commonly performed operation. Against this background, it is important to understand the physiological mechanisms by which gastric bypass induces and maintains body weight loss. These mechanisms are yet not fully understood, but may include reduced hunger and increased satiation, increased energy expenditure, altered preference for food high in fat and sugar, altered salt and water handling of the kidney as well as alterations in gut microbiota. Such changes seen after gastric bypass may at least partly stem from how the surgery alters the hormonal milieu because gastric bypass increases the postprandial release of peptide-YY (PYY) and glucagon-like-peptide-1 (GLP-1), hormones that are released by the gut in the presence of nutrients and that reduce eating. During the last two decades numerous studies using rats have been carried out to further investigate physiological changes after gastric bypass. The gastric bypass rat model has proven to be a valuable experimental tool not least as it closely mimics the time profile and magnitude of human weight loss, but also allows researchers to control and manipulate critical anatomic and physiologic factors including the use of appropriate controls. Consequently, there is a wide array of rat gastric bypass models available in the literature reviewed elsewhere in more detail. The description of the exact surgical technique of these models varies widely and differs e.g. in terms of pouch size, limb lengths, and the preservation of the vagal nerve. If reported, mortality rates seem to range from 0 to 35%. Furthermore, surgery has been carried out almost exclusively in male

  13. Water-mediated ion-ion interactions are enhanced at the water vapor-liquid interface.

    PubMed

    Venkateshwaran, Vasudevan; Vembanur, Srivathsan; Garde, Shekhar

    2014-06-17

    There is overwhelming evidence that ions are present near the vapor-liquid interface of aqueous salt solutions. Charged groups can also be driven to interfaces by attaching them to hydrophobic moieties. Despite their importance in many self-assembly phenomena, how ion-ion interactions are affected by interfaces is not understood. We use molecular simulations to show that the effective forces between small ions change character dramatically near the water vapor-liquid interface. Specifically, the water-mediated attraction between oppositely charged ions is enhanced relative to that in bulk water. Further, the repulsion between like-charged ions is weaker than that expected from a continuum dielectric description and can even become attractive as the ions are drawn to the vapor side. We show that thermodynamics of ion association are governed by a delicate balance of ion hydration, interfacial tension, and restriction of capillary fluctuations at the interface, leading to nonintuitive phenomena, such as water-mediated like charge attraction. "Sticky" electrostatic interactions may have important consequences on biomolecular structure, assembly, and aggregation at soft liquid interfaces. We demonstrate this by studying an interfacially active model peptide that changes its structure from α-helical to a hairpin-turn-like one in response to charging of its ends.

  14. 21 CFR 870.4430 - Cardiopulmonary bypass intracardiac suction control.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass intracardiac suction control. 870.4430 Section 870.4430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4430 Cardiopulmonary bypass intracardiac suction control. (a) Identification. A cardiopulmonary bypass...

  15. 21 CFR 870.4430 - Cardiopulmonary bypass intracardiac suction control.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass intracardiac suction control. 870.4430 Section 870.4430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4430 Cardiopulmonary bypass intracardiac suction control. (a) Identification. A cardiopulmonary bypass...

  16. Modeling Sediment Bypassing around Rocky Headlands

    NASA Astrophysics Data System (ADS)

    George, D. A.; Largier, J. L.; Pasternack, G. B.; Erikson, L. H.; Storlazzi, C. D.; Barnard, P.

    2016-12-01

    Sediment bypassing rocky headlands remains understudied despite the importance of characterizing littoral processes and sediment budgets for erosion abatement, climate change adaptation, and beach management. This study was developed to identify controlling factors on and the mechanisms supporting sediment bypassing. Sediment flux around four idealized rocky headlands was investigated using the hydrodynamic model Delft3D and spectral wave model SWAN. The experimental design involved 120 simulations to explore the influence of headland morphology, substrate composition, sediment grain size, and oceanographic forcing. Headlands represented sizes and shapes found in natural settings, grain sizes ranged from fine to medium sand, and substrates from sandy beds to offshore bedrock reefs. The oceanography included a constructed representative tide, an alongshore background current, and four wave conditions derived from observational records in the eastern Pacific Ocean. A bypassing ratio was developed for alongshore flux between upstream and downstream cross-shore transects to determine the degree of blockage by a headland. Results showed that northwesterly oblique large waves (Hs = 7 m, Tp = 16 s) generated the most flux around headlands, whereas directly incident waves blocked flux across a headland apex. The headland shape heavily influenced the sediment fate by changing the relative angle between the shoreline and the incident waves. The bypassing ratio characterized each headland's capacity to allow alongshore flux under different wave conditions. All headlands may allow flux, although larger ones block sediment more effectively, promoting their ability to be littoral cell boundaries compared to smaller headlands. The controlling factors on sediment bypassing were determined to be wave angle, shape and size of the headland, and sediment grain size. This novel numerical modeling study advances headland modeling from the generic realm to broadly applicable classes of

  17. Simple training tricks for mastering and taming bypass procedures in neurosurgery

    PubMed Central

    Hafez, Ahmad; Raj, Rahul; Lawton, Michael T.; Niemelä, Mika

    2017-01-01

    Background: Neurosurgeons devoted to bypass neurosurgery or revascularization neurosurgery are becoming scarcer. From a practical point of view, “bypass neurosurgeons” are anastomosis makers, vessels technicians, and time-racing repairers of vessel walls. This requires understanding the key features and hidden tricks of bypass surgery. The goal of this paper is to provide simple and inexpensive tricks for taming the art of bypass neurosurgery. Most of these tricks and materials described can be borrowed, donated, or purchased inexpensively. Methods: We performed a review of relevant training materials and recorded videos for training bypass procedures for 3 years between June 2014 and July 2017. In total, 1,300 training bypass procedures were performed, of which 200 procedures were chosen for this paper. Results: A training laboratory bypass procedures is required to enable a neurosurgeon to develop the necessary skills. The important skills for training bypass procedures gained through meticulous practice to be as reflexes are coordination, speed, agility, flexibility, and reaction time. Bypassing requires synchronization between the surgeon's gross movements, fine motoric skills, and mental strength. The suturing rhythm must be timed in a brain–body–hand fashion. Conclusion: Bypass-training is a critical part of neurosurgical training and not for a selected few. Diligent and meticulous training can enable every neurosurgeon to tame the art of bypass neurosurgery. This requires understanding the key features and hidden tricks of bypass surgery, as well as uncountable hours of training. In bypass neurosurgery, quality and time goes hand in hand. PMID:29285411

  18. 21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...

  19. 21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4300 Cardiopulmonary bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used...

  20. Role of Co-Vapors in Vapor Deposition Polymerization

    PubMed Central

    Lee, Ji Eun; Lee, Younghee; Ahn, Ki-Jin; Huh, Jinyoung; Shim, Hyeon Woo; Sampath, Gayathri; Im, Won Bin; Huh, Yang–Il; Yoon, Hyeonseok

    2015-01-01

    Polypyrrole (PPy)/cellulose (PPCL) composite papers were fabricated by vapor phase polymerization. Importantly, the vapor-phase deposition of PPy onto cellulose was assisted by employing different co-vapors namely methanol, ethanol, benzene, water, toluene and hexane, in addition to pyrrole. The resulting PPCL papers possessed high mechanical flexibility, large surface-to-volume ratio, and good redox properties. Their main properties were highly influenced by the nature of the co-vaporized solvent. The morphology and oxidation level of deposited PPy were tuned by employing co-vapors during the polymerization, which in turn led to change in the electrochemical properties of the PPCL papers. When methanol and ethanol were used as co-vapors, the conductivities of PPCL papers were found to have improved five times, which was likely due to the enhanced orientation of PPy chain by the polar co-vapors with high dipole moment. The specific capacitance of PPCL papers obtained using benzene, toluene, water and hexane co-vapors was higher than those of the others, which is attributed to the enlarged effective surface area of the electrode material. The results indicate that the judicious choice and combination of co-vapors in vapor-deposition polymerization (VDP) offers the possibility of tuning the morphological, electrical, and electrochemical properties of deposited conducting polymers. PMID:25673422

  1. Bypassing An Open-Circuit Power Cell

    NASA Technical Reports Server (NTRS)

    Wannemacher, Harry E.

    1994-01-01

    Collection of bypass circuits enables battery consisting series string of cells to continue to function when one of its cells fails in open-circuit (high-resistance) condition. Basic idea simply to shunt current around defective cell to prevent open circuit from turning off battery altogether. Bypass circuits dissipate little power and are nearly immune to false activation.

  2. Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Lstiburek, J. W.

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane.more » As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design.« less

  3. Roux-en-Y Gastric Bypass Operation in Rats

    PubMed Central

    Bueter, Marco; Abegg, Kathrin; Seyfried, Florian; Lutz, Thomas A.; le Roux, Carel W.

    2012-01-01

    Currently, the most effective therapy for the treatment of morbid obesity to induce significant and maintained body weight loss with a proven mortality benefit is bariatric surgery1,2. Consequently, there has been a steady rise in the number of bariatric operations done worldwide in recent years with the Roux-en-Y gastric bypass (gastric bypass) being the most commonly performed operation3. Against this background, it is important to understand the physiological mechanisms by which gastric bypass induces and maintains body weight loss. These mechanisms are yet not fully understood, but may include reduced hunger and increased satiation4,5, increased energy expenditure6,7, altered preference for food high in fat and sugar8,9, altered salt and water handling of the kidney10 as well as alterations in gut microbiota11. Such changes seen after gastric bypass may at least partly stem from how the surgery alters the hormonal milieu because gastric bypass increases the postprandial release of peptide-YY (PYY) and glucagon-like-peptide-1 (GLP-1), hormones that are released by the gut in the presence of nutrients and that reduce eating12. During the last two decades numerous studies using rats have been carried out to further investigate physiological changes after gastric bypass. The gastric bypass rat model has proven to be a valuable experimental tool not least as it closely mimics the time profile and magnitude of human weight loss, but also allows researchers to control and manipulate critical anatomic and physiologic factors including the use of appropriate controls. Consequently, there is a wide array of rat gastric bypass models available in the literature reviewed elsewhere in more detail 13-15. The description of the exact surgical technique of these models varies widely and differs e.g. in terms of pouch size, limb lengths, and the preservation of the vagal nerve. If reported, mortality rates seem to range from 0 to 35%15. Furthermore, surgery has been carried out

  4. Design, fabrication and testing of porous tungsten vaporizers for mercury ion thrusters

    NASA Technical Reports Server (NTRS)

    Zavesky, R.; Kroeger, E.; Kami, S.

    1983-01-01

    The dispersions in the characteristics, performance and reliability of vaporizers for early model 30-cm thrusters were investigated. The purpose of the paper is to explore the findings and to discuss the approaches that were taken to reduce the observed dispersion and present the results of a program which validated those approaches. The information that is presented includes porous tungsten materials specifications, a discussion of assembly procedures, and a description of a test program which screens both material and fabrication processes. There are five appendices providing additional detail in the areas of vaporizer contamination, nitrogen flow testing, bubble testing, porosimeter testing, and mercury purity. Four neutralizers, seven cathodes and five main vaporizers were successfully fabricated, tested, and operated on thrusters. Performance data from those devices is presented and indicates extremely repeatable results from using the design and fabrication procedures.

  5. Strong Fluorescent Smart Organogel as a Dual Sensing Material for Volatile Acid and Organic Amine Vapors.

    PubMed

    Xue, Pengchong; Yao, Boqi; Wang, Panpan; Gong, Peng; Zhang, Zhenqi; Lu, Ran

    2015-11-23

    An L-phenylalanine derivative (C12PhBPCP) consisting of a strong emission fluorophore with benzoxazole and cyano groups is designed and synthesized to realize dual responses to volatile acid and organic amine vapors. The photophysical properties and self-assembly of the said derivative in the gel phase are also studied. C12PhBPCP can gelate organic solvents and self-assemble into 1 D nanofibers in the gels. UV/Vis absorption spectral results show H-aggregate formation during gelation, which indicates strong exciton coupling between fluorophores. Both wet gel and xerogel emit strong green fluorescence because the cyano group suppresses fluorescence quenching in the self-assemblies. Moreover, the xerogel film with strong green fluorescence can be used as a dual chemosensor for quantitative detection of volatile acid and organic amine vapors with fast response times and low detection limits owing to its large surface area and amplified fluorescence quenching. The detection limits are 796 ppt and 25 ppb for gaseous aniline and trifluoroacetic acid (TFA), respectively. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Ultra High Bypass Integrated System Test

    NASA Image and Video Library

    2015-09-14

    NASA’s Environmentally Responsible Aviation Project, in collaboration with the Federal Aviation Administration (FAA) and Pratt & Whitney, completed testing of an Ultra High Bypass Ratio Turbofan Model in the 9’ x 15’ Low Speed Wind Tunnel at NASA Glenn Research Center. The fan model is representative of the next generation of efficient and quiet Ultra High Bypass Ratio Turbofan Engine designs.

  7. Coronary Artery Bypass

    MedlinePlus

    ... 000 procedures performed each year in the United States. Arteries can become clogged over time by the buildup of fatty plaque. Bypass surgery improves the blood flow to the heart with a new route or “ ...

  8. Tailored Assembly of 2D Heterostructures beyond Graphene

    DTIC Science & Technology

    2017-05-11

    liquid crystal and catalyst application. Another important approach we have explored during this project is the solution phase assembly of two...graphene oxide, and its potential functionalities in liquid crystal and catalyst application. Another important approach we have explored during...exfoliation, liquid phase exfoliation, and chemical vapor deposition, and opened up new opportunities to graphene based platform for novel

  9. Surface mediated assembly of small, metastable gold nanoclusters

    NASA Astrophysics Data System (ADS)

    Pettibone, John M.; Osborn, William A.; Rykaczewski, Konrad; Talin, A. Alec; Bonevich, John E.; Hudgens, Jeffrey W.; Allendorf, Mark D.

    2013-06-01

    The unique properties of metallic nanoclusters are attractive for numerous commercial and industrial applications but are generally less stable than nanocrystals. Thus, developing methodologies for stabilizing nanoclusters and retaining their enhanced functionality is of great interest. We report the assembly of PPh3-protected Au9 clusters from a heterogeneous mixture into films consisting of sub 3 nm nanocluster assemblies. The depositing nanoclusters are metastable in solution, but the resulting nanocluster assemblies are stabilized indefinitely in air or fresh solvent. The films exhibit distinct structure from Au nanoparticles observed by X-ray diffraction, and film dissolution data support the preservation of small nanoclusters. UV-Vis spectroscopy, electrospray ionization mass spectrometry, X-ray photoelectron spectroscopy and electron microscopy are used to elucidate information regarding the nanocluster formation and assembly mechanism. Preferential deposition of nanocluster assemblies can be achieved on multiple substrates, including polymer, Cr, Si, SiO2, SiNx, and metal-organic frameworks (MOFs). Unlike other vapor phase coating processes, nanocluster assembly on the MIL-68(In) MOF crystal is capable of preferentially coating the external surface and stabilizing the crystal structure in hydrothermal conditions, which should enhance their storage, separation and delivery capabilities.The unique properties of metallic nanoclusters are attractive for numerous commercial and industrial applications but are generally less stable than nanocrystals. Thus, developing methodologies for stabilizing nanoclusters and retaining their enhanced functionality is of great interest. We report the assembly of PPh3-protected Au9 clusters from a heterogeneous mixture into films consisting of sub 3 nm nanocluster assemblies. The depositing nanoclusters are metastable in solution, but the resulting nanocluster assemblies are stabilized indefinitely in air or fresh solvent. The

  10. Bypass diode for a solar cell

    DOEpatents

    Rim, Seung Bum [Palo Alto, CA; Kim, Taeseok [San Jose, CA; Smith, David D [Campbell, CA; Cousins, Peter J [Menlo Park, CA

    2012-03-13

    Bypass diodes for solar cells are described. In one embodiment, a bypass diode for a solar cell includes a substrate of the solar cell. A first conductive region is disposed above the substrate, the first conductive region of a first conductivity type. A second conductive region is disposed on the first conductive region, the second conductive region of a second conductivity type opposite the first conductivity type.

  11. Passage of downstream migrant American eels through an airlift-assisted deep bypass

    USGS Publications Warehouse

    Haro, Alexander J.; Watten, Barnaby J.; Noreika, John

    2016-01-01

    Traditional downstream guidance and bypass facilities for anadromous fishes (i.e., surface bypasses, surface guidance structures, and behavioral barriers) have frequently been ineffective for anguillid eels. Because eels typically spend the majority of their time near the bottom in the vicinity of intake structures, deep bypass structures with entrances near the bottom hold promise for increased effectiveness, thereby aiding in the recovery of this important species. A new design of a deep bypass system that uses airlift technology (the Conte Airlift Bypass) to induce flow in a bypass pipe was tested in a simulated intake entrance environment under controlled laboratory conditions. Water velocities of 0.9–1.5 m s−1 could be generated at the bypass entrance (opening with 0.073 m2 area), with corresponding flows through the bypass pipe of 0.07–0.11 m3 s−1. Gas saturation and hydrostatic pressure within the bypass pipe did not vary appreciably from a control (no air) condition under tested airflows. Migratory silver-phase American eels (Anguilla rostrata) tested during dark conditions readily located, entered, and passed through the bypass; initial avoidance rates (eels approaching but not entering the bypass entrance) were lower at higher entrance velocities. Eels that investigated the bypass pipe entrance tended to enter headfirst, but those that then exited the pipe upstream did so more frequently at lower entrance velocities. Eels appeared to swim against the flow while being transported downstream through the pipe; median transit times through the bypass for each test velocity ranged from 5.8 to 12.2 s, with transit time decreasing with increasing entrance velocity. Eels did not show strong avoidance of the vertical section of the pipe which contained injected air. No mortality or injury of bypassed eels was observed, and individual eels repeatedly passed through the bypass at rates of up to 40 passes per hour, suggesting that individuals do not

  12. Coronary Artery Bypass Surgery: MedlinePlus Health Topic

    MedlinePlus

    ... Coronary Artery Bypass (Texas Heart Institute) Also in Spanish Coronary Artery Bypass Graft Surgery (Beyond the Basics) ( ... Radiology, Radiological Society of North America) Also in Spanish Living With Cardiac Rehabilitation: MedlinePlus Health Topic (National ...

  13. Life Testing of the Vapor Compression Distillation/Urine Processing Assembly (VCD/UPA) at the Marshall Space Flight Center (1993 to 1997)

    NASA Technical Reports Server (NTRS)

    Wieland, P.; Hutchens, C.; Long, D.; Salyer, B.

    1998-01-01

    Wastewater and urine generated on the International Space Station will be processed to recover pure water using vapor compression distillation (VCD). To verify the long-term reliability and performance of the VCD Urine Processor Assembly (UPA), life testing was performed at the Marshall Space Flight Center (MSFC) from January 1993 to April 1996. Two UPA'S, the VCD-5 and VCD-5A, were tested for 204 days and 665 days, respectively. The compressor gears and the distillation centrifuge drive belt were found to have operating lives of approximately 4,800 hours, equivalent to 3.9 years of operation on ISS for a crew of three at an average processing rate of 1.76 kg/h (3.97 lb/h). Precise alignment of the flex-splines of the fluids and purge pump motor drives is essential to avoid premature failure after about 400 hours of operation. Results indicate that, with some design and procedural modifications and suitable quality control, the required performance and operational life can be met with the VCD/UPA.

  14. Morphology and Pattern Control of Diphenylalanine Self-Assembly via Evaporative Dewetting.

    PubMed

    Chen, Jiarui; Qin, Shuyu; Wu, Xinglong; Chu, And Paul K

    2016-01-26

    Self-assembled peptide nanostructures have unique physical and biological properties and promising applications in electrical devices and functional molecular recognition. Although solution-based peptide molecules can self-assemble into different morphologies, it is challenging to control the self-assembly process. Herein, controllable self-assembly of diphenylalanine (FF) in an evaporative dewetting solution is reported. The fluid mechanical dimensionless numbers, namely Rayleigh, Marangoni, and capillary numbers, are introduced to control the interaction between the solution and FF molecules in the self-assembly process. The difference in the film thickness reflects the effects of Rayleigh and Marangoni convection, and the water vapor flow rate reveals the role of viscous fingering in the emergence of aligned FF flakes. By employing dewetting, various FF self-assembled patterns, like concentric and spokelike, and morphologies, like strips and hexagonal tubes/rods, can be produced, and there are no significant lattice structural changes in the FF nanostructures.

  15. Development of environmentally conscious cleaning process for leadless chip carrier assemblies. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adams, B.E.

    1995-04-01

    A cross-functional team of process, product, quality, material, and design lab engineers was assembled to develop an environmentally friendly cleaning process for leadless chip carrier assemblies (LCCAs). Using flush and filter testing, Auger surface analysis, GC-Mass spectrophotometry, production yield results, and electrical testing results over an extended testing period, the team developed an aqueous cleaning process for LCCAs. The aqueous process replaced the Freon vapor degreasing/ultrasonic rinse process.

  16. 21 CFR 870.4370 - Roller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Roller-type cardiopulmonary bypass blood pump. 870... Roller-type cardiopulmonary bypass blood pump. (a) Identification. A roller-type cardiopulmonary bypass blood pump is a device that uses a revolving roller mechanism to pump the blood through the...

  17. 21 CFR 870.4360 - Nonroller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonroller-type cardiopulmonary bypass blood pump... Nonroller-type cardiopulmonary bypass blood pump. (a) Identification. A nonroller-type cardiopulmonary bypass blood pump is a device that uses a method other than revolving rollers to pump the blood through...

  18. 21 CFR 870.4360 - Nonroller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonroller-type cardiopulmonary bypass blood pump... Nonroller-type cardiopulmonary bypass blood pump. (a) Identification. A nonroller-type cardiopulmonary bypass blood pump is a device that uses a method other than revolving rollers to pump the blood through...

  19. 21 CFR 870.4370 - Roller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Roller-type cardiopulmonary bypass blood pump. 870... Roller-type cardiopulmonary bypass blood pump. (a) Identification. A roller-type cardiopulmonary bypass blood pump is a device that uses a revolving roller mechanism to pump the blood through the...

  20. 21 CFR 870.4370 - Roller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Roller-type cardiopulmonary bypass blood pump. 870... Roller-type cardiopulmonary bypass blood pump. (a) Identification. A roller-type cardiopulmonary bypass blood pump is a device that uses a revolving roller mechanism to pump the blood through the...

  1. 21 CFR 870.4370 - Roller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Roller-type cardiopulmonary bypass blood pump. 870... Roller-type cardiopulmonary bypass blood pump. (a) Identification. A roller-type cardiopulmonary bypass blood pump is a device that uses a revolving roller mechanism to pump the blood through the...

  2. 21 CFR 870.4360 - Nonroller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonroller-type cardiopulmonary bypass blood pump... Nonroller-type cardiopulmonary bypass blood pump. (a) Identification. A nonroller-type cardiopulmonary bypass blood pump is a device that uses a method other than revolving rollers to pump the blood through...

  3. 21 CFR 870.4370 - Roller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Roller-type cardiopulmonary bypass blood pump. 870... Roller-type cardiopulmonary bypass blood pump. (a) Identification. A roller-type cardiopulmonary bypass blood pump is a device that uses a revolving roller mechanism to pump the blood through the...

  4. 21 CFR 870.4360 - Nonroller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonroller-type cardiopulmonary bypass blood pump... Nonroller-type cardiopulmonary bypass blood pump. (a) Identification. A nonroller-type cardiopulmonary bypass blood pump is a device that uses a method other than revolving rollers to pump the blood through...

  5. 21 CFR 870.4360 - Nonroller-type cardiopulmonary bypass blood pump.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonroller-type cardiopulmonary bypass blood pump... Nonroller-type cardiopulmonary bypass blood pump. (a) Identification. A nonroller-type cardiopulmonary bypass blood pump is a device that uses a method other than revolving rollers to pump the blood through...

  6. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  7. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  8. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  9. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  10. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  11. Results of the Vapor Compression Distillation Flight Experiment (VCD-FE)

    NASA Technical Reports Server (NTRS)

    Hutchens, Cindy; Graves, Rex

    2004-01-01

    Vapor Compression Distillation (VCD) is the chosen technology for urine processing aboard the International Space Station (ISS). Key aspects of the VCD design have been verified and significant improvements made throughout the ground;based development history. However, an important element lacking from previous subsystem development efforts was flight-testing. Consequently, the demonstration and validation of the VCD technology and the investigation of subsystem performance in micro-gravity were the primary goals of the VCD-FE. The Vapor Compression Distillation Flight Experiment (VCD-E) was a flight experiment aboard the Space Shuttle Columbia during the STS-107 mission. The VCD-FE was a full-scale developmental version of the Space Station Urine Processor Assembly (UPA) and was designed to test some of the potential micro-gravity issues with the design. This paper summarizes the experiment results.

  12. Surface mediated assembly of small, metastable gold nanoclusters.

    PubMed

    Pettibone, John M; Osborn, William A; Rykaczewski, Konrad; Talin, A Alec; Bonevich, John E; Hudgens, Jeffrey W; Allendorf, Mark D

    2013-07-21

    The unique properties of metallic nanoclusters are attractive for numerous commercial and industrial applications but are generally less stable than nanocrystals. Thus, developing methodologies for stabilizing nanoclusters and retaining their enhanced functionality is of great interest. We report the assembly of PPh3-protected Au9 clusters from a heterogeneous mixture into films consisting of sub 3 nm nanocluster assemblies. The depositing nanoclusters are metastable in solution, but the resulting nanocluster assemblies are stabilized indefinitely in air or fresh solvent. The films exhibit distinct structure from Au nanoparticles observed by X-ray diffraction, and film dissolution data support the preservation of small nanoclusters. UV-Vis spectroscopy, electrospray ionization mass spectrometry, X-ray photoelectron spectroscopy and electron microscopy are used to elucidate information regarding the nanocluster formation and assembly mechanism. Preferential deposition of nanocluster assemblies can be achieved on multiple substrates, including polymer, Cr, Si, SiO2, SiNx, and metal-organic frameworks (MOFs). Unlike other vapor phase coating processes, nanocluster assembly on the MIL-68(In) MOF crystal is capable of preferentially coating the external surface and stabilizing the crystal structure in hydrothermal conditions, which should enhance their storage, separation and delivery capabilities.

  13. Feasibility and safety of minimized cardiopulmonary bypass in major aortic surgery

    PubMed Central

    Momin, Aziz U.; Sharabiani, Mansour T. A.; Kidher, Emadin; Najefi, Ali; Mulholland, John W.; Reeves, Barnaby C.; Angelini, Gianni D.; Anderson, Jon R.

    2013-01-01

    OBJECTIVES Conventional cardiopulmonary bypass causes haemodilution and is a trigger of systemic inflammatory reactions, coagulopathy and organ failure. Miniaturized cardiopulmonary bypass has been proposed as a way to reduce these deleterious effects of conventional cardiopulmonary bypass and to promote a more physiological state. The use of miniaturized cardiopulmonary bypass has been reported in low-risk patients undergoing valve and coronary artery bypass graft (CABG) surgery. However, little is known about its application in major aortic surgery. METHODS From February 2007 to September 2010, 49 patients underwent major aortic surgery using the Hammersmith miniaturized cardiopulmonary bypass (ECCO, Sorin). Data were extracted from medical records to characterize preoperative comorbidities (EuroSCORE), perioperative complications and the use of blood products. The same data were collected and described for 328 consecutive patients having similar surgery with conventional cardiopulmonary bypass at the Bristol Heart Institute, our twinned centre, during the same period. RESULTS The miniaturized cardiopulmonary bypass group had a median EuroSCORE of 8 [inter-quartile range (IQR): 5–11], 13% had preoperative renal dysfunction and 20% of operations were classified as emergency or salvage. Thirty-day mortalities were 6.4; and 69, 67 and 74% had ≥1 unit of red cells, fresh frozen plasma (FFP) and platelets transfused, respectively. Eight percent of patients experienced a renal complication, and 8% a neurological complication. The conventional cardiopulmonary bypass group was similar, with a EuroSCORE of 8 (IQR: 6–10); 30-day mortalities were 9.4; and 68, 62 and 74% had ≥1 unit of red cells, FFP and platelets transfused, respectively. The proportions experiencing renal and neurological complications were 14 and 5%. CONCLUSIONS Our experience suggests that miniaturized cardiopulmonary bypass is safe and feasible for use in major aortic cardiac surgery. A

  14. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  15. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  16. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  17. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  18. 21 CFR 870.4220 - Cardiopulmonary bypass heart-lung machine console.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass heart-lung machine console... Cardiopulmonary bypass heart-lung machine console. (a) Identification. A cardiopulmonary bypass heart-lung machine... heart-lung machine. The console is designed to interface with the basic units used in a gas exchange...

  19. Contrast MR of the brain after high-perfusion cardiopulmonary bypass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simonson, T.M.; Yuh, W.T.C.; Hindman, B.J.

    1994-01-01

    To study the efficacy of contrast MR imaging in the evaluation of central nervous system complications in the cardiopulmonary bypass patient and attempt to explain their pathophysiology based on the MR appearance and the cardiopulmonary bypass protocol. Nineteen patients were prospectively studied with contrast MR examinations the day before and 3 to 7 days after cardiopulmonary bypass, to determine the nature, extent, and number of new postoperative MR abnormalities. Cardiopulmonary bypass parameters used in our institution included: membrane oxygenation, arterial filtration with a pore size of 25 [mu]m, and a relatively high perfusion rate to produce a cardiac index ofmore » 2.0 to 2.5 L min per m[sup 2]. The preoperative noncontrast MR examination showed age-related changes and/or signs of ischemia in 60% of patients on the day before surgery. However, there was no abnormal enhancement or new T2 abnormalities on any postoperative MR examination to suggest hypoperfusion or emboli. None of the 19 patients developed overt neurologic deficits postoperatively. Review of the cardiopulmonary bypass protocol used indicated significant variations in technique at different institutions. Contrast MR imaging demonstrated no new abnormalities in patients after cardiopulmonary bypass performed with strict in-line arterial filtration and relatively high perfusion. MR imaging is feasible in the early postoperative period after cardiopulmonary bypass and may offer a convenient method for evaluation of the neurologic impact of technical factors associated with cardiopulmonary bypass. 17 refs.« less

  20. Li-Ion Battery By-Pass Removal Qualification

    NASA Astrophysics Data System (ADS)

    Borthomieu, Y.; Pasquier, E.

    2005-05-01

    The reasons of the by-pass use on Space batteries is to avoid open circuit, short-circuit and dramatic performances drift on the power system. By-pass diodes are currently used in NiH2 batteries due to the high probability of open circuit at cell level. This probability is mainly linked to the possibility to have a hydrogen leak within the pressure vessel due to the high operating pressure (70 bars) that can induce cell open circuit.For the Lithium-Ion batteries, first items had bypass implemented by similarity, but:All the cell failure cases have been analyzed at battery level:- Cell Open circuit:In contrast to NiCd and NiH2 cells, Li-Ion cells can be put in parallel due to the fact the open circuit voltage (OCV) is linked to the State Of Charge (SOC).With cells in parallel, a battery open circuit failure can never be encountered even with a cell in open circuit.- Cell Short circuit:In case of cell short, the entire cells within the module will be shorted.- Cell capacity spread:If the capacities of cells in series are strongly diverging, the worst module limits the battery. In case the battery is no more able to deliver the requested power for which it was designed, the worst module has to be reversed. In reversal, a Li-Ion cell is self-shorted. So, the strong capacity decrease in one module leads to the short of this module.These three failure cases cover all the possible Li-Ion failure root causes.Considering these three events, the analysis demonstrates that the Li-Ion battery still functions in any case without any by-pass system because the design of the battery size always takes into account the loss of one module.Nevertheless, the by-pass removal should allow to:- Improve the battery reliability as each bypass unit represents a single - Reduce by at least 30 % of the total price of the battery,- Reduce significant weight at battery level,- Shorten the battery manufacturing lead time (at least8 months for by-pass purchasing), - Avoid US export licenses

  1. Piston pump and method of reducing vapor lock

    DOEpatents

    Phillips, Benjamin A.; Harvey, Michael N.

    2000-02-15

    A pump includes a housing defining a cavity, at least one bore, a bore inlet, and a bore outlet. The bore extends from the cavity to the outlet and the inlet communicates with the bore at a position between the cavity and the outlet. A crankshaft is mounted in supports and has an eccentric portion disposed in the cavity. The eccentric portion is coupled to a piston so that rotation of the crankshaft reciprocates the piston in the bore between a discharge position an intake position. The bore may be offset from an axis of rotation to reduce bending of the piston during crankshaft rotation. During assembly of the pump, separate parts of the housing can be connected together to facilitate installation of internal pumping components. Also disclosed is a method of reducing vapor lock by mixing vapor and liquid portions of a substance and introducing the mixture into a piston bore.

  2. Piston pump and method of reducing vapor lock

    DOEpatents

    Phillips, Benjamin A.; Harvey, Michael N.

    2001-01-30

    A pump includes a housing defining a cavity, at least one bore, a bore inlet, and a bore outlet. The bore extends from the cavity to the outlet and the inlet communicates with the bore at a position between the cavity and the outlet. A crankshaft is mounted in supports and has an eccentric portion disposed in the cavity. The eccentric portion is coupled to a piston so that rotation of the crankshaft reciprocates the piston in the bore between a discharge position an intake position. The bore may be offset from an axis of rotation to reduce bending of the piston during crankshaft rotation. During assembly of the pump, separate parts of the housing can be connected together to facilitate installation of internal pumping components. Also disclosed is a method of reducing vapor lock by mixing vapor and liquid portions of a substance and introducing the mixture into a piston bore.

  3. Alterations of sucrose preference after Roux-en-Y gastric bypass.

    PubMed

    Bueter, M; Miras, A D; Chichger, H; Fenske, W; Ghatei, M A; Bloom, S R; Unwin, R J; Lutz, T A; Spector, A C; le Roux, C W

    2011-10-24

    Roux-en-Y gastric bypass (gastric bypass) patients reportedly have changes in perception and consumption of sweet-tasting foods. This study aimed to further investigate alterations in sweet food intake in rats and sucrose detection in humans after gastric bypass. Wistar rats were randomized to gastric bypass or sham-operations and preference for sucrose (sweet), sodium chloride (salty), citric acid (sour) and quinine hydrochloride (bitter) was assessed with standard two-bottle intake tests (vs. water). Intestinal T1R2 and T1R3 expression and plasma levels of glucagon-like-peptide 1 (GLP-1) and peptide YY (PYY) were measured. Furthermore, obese patients and normal weight controls were tested for sucrose taste detection thresholds pre- and postoperatively. Visual analogue scales measuring hedonic perception were used to determine the sucrose concentration considered by patients and controls as "just about right" pre- and postoperatively. Gastric bypass reduced the sucrose intake relative to water in rats (p<0.001). Preoperative sucrose exposure reduced this effect. Preference or aversion for compounds representative of other taste qualities in naïve rats remained unaffected. Intestinal T1R2 and T1R3 expression was significantly decreased in the alimentary limb while plasma levels of GLP-1 and PYY were elevated after bypass in rats (p=0.01). Bypass patients showed increased taste sensitivity to low sucrose concentrations compared with controls (p<0.05), but both groups considered the same sucrose concentration as "just about right" postoperatively. In conclusion, gastric bypass reduces sucrose intake relative to water in sucrose-naïve rats, but preoperative sucrose experience attenuates this effect. Changes in sucrose taste detection do not predict hedonic taste ratings of sucrose in bypass patients which remain unchanged. Thus, factors other than the unconditional affective value of the taste may also play a role in determining food preferences after gastric bypass

  4. RETORT ASSEMBLY

    DOEpatents

    Loomis, C.C.; Ash, W.J.

    1957-11-26

    An improved retort assembly useful in the thermal reduction of volatilizable metals such as magnesium and calcium is described. In this process a high vacuum is maintained in the retort, however the retort must be heated to very high temperatures while at the same time the unloading end must bo cooled to condense the metal vapors, therefore the retention of the vacuum is frequently difficult due to the thermal stresses involved. This apparatus provides an extended condenser sleeve enclosed by the retort cover which forms the vacuum seal. Therefore, the seal is cooled by the fluid in the condenser sleeve and the extreme thermal stresses found in previous designs together with the deterioration of the sealing gasket caused by the high temperatures are avoided.

  5. Are patients bypassing paediatric cardiology outreach clinics?

    PubMed

    Fletcher, Alexander; Samson, Ray; McLeod, Karen

    2017-07-01

    Previous studies have identified that receiving specialist care close to home can positively influence patients' experience. Despite this, a review of cardiology outpatient appointments at the Royal Hospital for Children in Glasgow demonstrated that a large number of families are bypassing their local children's cardiology centre to attend cardiac clinics at the specialist children's surgical centre. We used patient questionnaire, audit of local facilities, and examined the relationship between diagnosis and bypass numbers to better understand factors influencing this trend. Our results suggest that patient preference, short travelling distance to specialist children's cardiac centre, a more severe cardiac diagnosis, and inconsistent local facilities, expertise, and support are likely to influence a family's decision to bypass their local children's cardiology centre.

  6. Hyperammonemic syndrome after Roux-en-Y gastric bypass.

    PubMed

    Fenves, Andrew Z; Shchelochkov, Oleg A; Mehta, Ankit

    2015-04-01

    Hyperammonemic encephalopathy is an uncommon but severe complication of the Roux-en-Y gastric bypass surgery for obesity. Mechanisms underlying this complication are incompletely understood, resulting in delayed recognition and management. This study evaluated common laboratory findings and possible etiology of hyperammonemic encephalopathy after successful Roux-en-Y gastric bypass surgery. A retrospective review of 20 patients identified through our own clinical practice was conducted, with the addition of similar cases from other institutions identified through the review of literature. Patients presenting with hyperammonemic encephalopathy after Roux-en-Y gastric bypass surgery presented with overlapping clinical and laboratory findings. Common features included: (1) weight loss following successful Roux-en-Y gastric bypass for obesity; (2) hyperammonemic encephalopathy accompanied by elevated plasma glutamine levels; (3) absence of cirrhosis; (4) hypoalbuminemia; and (5) low plasma zinc levels. The mortality rate was 50%. Ninety-five percent of patients were women. Three patients were diagnosed with proximal urea cycle disorders. One patient experienced improvement in the hyperammonemia after surgical correction of spontaneous splenorenal shunt. Hyperammonemic encephalopathy after Roux-en-Y gastric bypass surgery is a newly recognized, potentially fatal syndrome with diverse pathophysiologic mechanisms encompassing genetic and nongenetic causes. © 2015 The Obesity Society.

  7. Preservation of myocardium during coronary artery bypass surgery.

    PubMed

    Kinoshita, Takeshi; Asai, Tohru

    2012-08-01

    Myocardial protection aims to prevent reversible post-ischemic cardiac dysfunction (myocardial stunning) and irreversible myocardial cell death (myocardial infarction) that occur as a consequence of myocardial ischemia and/or ischemic-reperfusion injury. Although the mortality rate for isolated coronary artery bypass grafting has been markedly reduced during the past decade, myocardial death, as evidenced by elevation in creatine kinase-myocardial band and/or cardiac troponin, is common. This is ascribed to suboptimal myocardial protection during cardiopulmonary bypass or with off-pump technique, early graft failure, distal embolization, and regional or global myocardial ischemia during surgery. An unmet need in contemporary coronary bypass surgery is to find more effective cardioprotective strategies that have the potential for decreasing the morbidity and mortality associated with suboptimal cardioprotection. In the present review article on myocardial protection in contemporary coronary artery bypass surgery, we attempt to elucidate the clinical problems, summarize the outcomes of selected phase III trials, and introduce new perspectives.

  8. Partitioning of residual D-limonene cleaner vapor among organic materials in weapons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeMay, J.D.

    1993-03-01

    D-limonene is a replacement solvent selected by Sandia and Allied-Signal to clean solder flux from electronics assemblies in firesets and programmers. D-limonene is much slower drying than the solvents it has replaced and this has raised concerns that residual quantities of the cleaner could be trapped in the electronics assemblies and eventually carried into warhead assemblies. This paper describes a study designed to evaluate how vapors from residual d-limonene cleaner would be partitioned among typical organic materials in a Livermore device. The goal was to identify possible compatibility problems arising from the use of d-limonene and, in particular, any interactionsmore » it may have with energetic materials. To predict the partitioning behavior of d-limonene, a simple model was developed and its predictions are compared to the experimental findings.« less

  9. Laparoscopic Band-Separated One Anastomosis Gastric Bypass.

    PubMed

    Ospanov, Oral B

    2016-09-01

    This video demonstrates laparoscopic band-separated one anastomosis gastric bypass-combining the advantages of banding and gastric bypass without stapler and cutter use. This is basically a gastrojejunal loop bypass above an obstructive band in the upper stomach. An adjustable low pressure "Medsil" gastric band was introduced in the abdomen and retracted through the retrogastric tunnel. The front wall of the stomach below the band was displaced in the upward direction through the ring band, increasing the size of the anterior portion of the stomach pouch so that a gastroenteroanastomosis could be created at this point. Gastro-gastric sutures were placed to create a gastro-gastric plication around the band and hold it in position. The band tubing was exteriorized and connected to a special port, which was secured to the abdominal wall fascia. A jejunal loop was created about 200 cm from the ligament of Treitz and anastomosed to the gastric pouch by hand using Vicryl 2/0 sutures. Between November 2015 and February 2016, the study was performed on 10 patients. The average operating time for all cases was 75 min (range 63-87). There was no morbidity or mortality. No complications were observed, including band erosion and band infection. Operation costs were about $2000 lower with this method than with standard gastric bypass surgery. Postop the patients lost weight by 3-4 kg per month. Preliminary results show that laparoscopic band-separated one anastomosis gastric bypass have feasibility, safety, efficacy, and reduced operating costs.

  10. 21 CFR 870.4290 - Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass adaptor, stopcock, manifold... Devices § 870.4290 Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting. (a) Identification. A cardiopulmonary bypass adaptor, stopcock, manifold, or fitting is a device used in cardiovascular diagnostic...

  11. 21 CFR 870.4290 - Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass adaptor, stopcock, manifold... Devices § 870.4290 Cardiopulmonary bypass adaptor, stopcock, manifold, or fitting. (a) Identification. A cardiopulmonary bypass adaptor, stopcock, manifold, or fitting is a device used in cardiovascular diagnostic...

  12. Resurrection of the in situ saphenous vein bypass. 1000 cases later.

    PubMed Central

    Leather, R P; Shah, D M; Chang, B B; Kaufman, J L

    1988-01-01

    Distal bypasses for the terminal stages of atherosclerotic occlusive disease manifest by chronic limb-threatening ischemia are among the most challenging arterial reconstructive procedures of surgeons today. The length and low flow rates of distal bypasses often exceed the functional limits of synthetic and even free vein grafts. However, the saphenous vein, when used in situ, provides a unique, viable, physiologically active, and hence antithrombogenic endothelial flow surface that is ideally suited for such bypasses. This paper presents the experience of the Albany Medical Center Hospital with the first 1000 in situ bypasses performed by the valve incision method over a 12-year period. Limb-threatening ischemia was the most common indication for surgery (91%). An in situ bypass was attempted in over 95% of unselected limbs and were completed in situ and in toto in 94%. 66% of the bypasses were carried out to the infrapopliteal level, and in more than 50% of the limbs, the distal vein diameter was less than 3.5 mm. The 30-day patency rate was 95%, and the cumulative patency rates, by life table analysis at 1, 2, 3, 4, and 5 years, were 90%, 86%, 84%, 80%, and 76%, respectively. The vein diameter, specific outflow vessel, level of distal anastomosis (length of bypass), inguinal inflow source used, and instrumental evolution had no significant effect on immediate or long-term bypass performance. PMID:3178331

  13. 20 CFR 631.18 - Federal by-pass authority.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Federal by-pass authority. 631.18 Section 631.18 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS UNDER... Secretary's intent to exercise by-pass authority and an opportunity to request and to receive a hearing...

  14. Sodium thiopental and mean arterial pressure during cardiopulmonary bypass.

    PubMed

    Dabbagh, Ali; Rajaei, Samira; Ahani, Mohammad Reza

    2011-06-01

    Sodium thiopental is known to have a number of cardiovascular effects, but injection into the cardiopulmonary bypass reservoir has not been studied. The effect of sodium thiopental on mean arterial blood pressure during cardiopulmonary bypass was assessed in 150 patients undergoing elective coronary artery bypass grafting. Sodium thiopental 3 mg · kg(-1) was administered via the cardiopulmonary bypass reservoir. Mean arterial pressure was recorded just before drug administration and at 15-sec intervals up to 120 sec afterwards. Compared to the baseline value, mean arterial pressure was significantly higher at 30, 45, 60, and 75 sec after drug administration, and it was significantly lower at 90, 105, and 120 sec. Sodium thiopental, in addition to its effects on myocardial tissue, acts initially as a potent vasopressor, and shortly after, as a potent vasodilator.

  15. A Solvent-Vapor Approach toward the Control of Block Ionomer Morphologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mineart, Kenneth P.; Lee, Byeongdu; Spontak, Richard J.

    Sulfonated block ionomers possess advantageous properties for a wide range of diverse applications such as desalination membranes, fuel cells, electroactive media, and photovoltaic devices. Unfortunately, their inherently high incompatibilities and glass transition temperatures e ff ectively prevent the use of thermal annealing, routinely employed to re fi ne the morphologies of nonionic block copolymers. An alternative approach is therefore required to promote morphological equilibration in block ionomers. The present study explores the morphological characteristics of midblock- sulfonated pentablock ionomers (SBIs) di ff ering in their degree of sulfonation (DOS) and cast from solution followed by solvent-vapor annealing (SVA). Transmission electronmore » microscopy con fi rms that fi lms deposited from di ff erent solvent systems form nonequilibrium morphologies due to solvent-regulated self-assembly and drying. A series of SVA tests performed with solvents varying in polarity reveals that exposing cast fi lms to tetrahydrofuran (THF) vapor for at least 2 h constitutes the most e ff ective SVA protocol, yielding the anticipated equilibrium morphology. That is, three SBI grades subjected to THF-SVA self-assemble into well-ordered lamellae wherein the increase in DOS is accompanied by an increase in lamellar periodicity, as measured by small-angle X-ray scattering.« less

  16. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  17. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass vascular catheter, cannula... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to...

  18. Abdominal Pain After Roux-En-Y Gastric Bypass for Morbid Obesity.

    PubMed

    Mala, Tom; Høgestøl, Ingvild

    2018-05-01

    Roux-en-Y gastric bypass is widely used as treatment of morbid obesity. Weight loss, effects on obesity-related co-morbidities and quality of life are well documented post Roux-en-Y gastric bypass. Other outcome measures are less well studied. This review explores aspects of prevalence, diagnostic evaluations, etiology, and treatment of abdominal pain specific to Roux-en-Y gastric bypass. The review is based on PubMed searches and clinical experience with Roux-en-Y gastric bypass. Symptoms in the early postoperative phase (<30 days) were not included. Based on limited evidence, up to about 30% of the patients may perceive recurrent abdominal pain post Roux-en-Y gastric bypass in the long term. A substantial subset of patients will need health-care evaluation for acute abdominal pain and hospital admission. The etiology of abdominal pain is heterogeneous and includes gallstone-related disease, intestinal obstruction, anastomotic ulcerations and strictures, intestinal dysmotility, dysfunctional eating, and food intolerance. Surgical treatment and guidance on diet and eating habits may allow symptom relief. The cause of pain remains undefined for a subset of patients. Impact of abdominal pain post Roux-en-Y gastric bypass on the perception of well-being, quality of life, and patient satisfaction with the procedure needs to be further evaluated and may be influenced by complex interactions between new symptoms post Roux-en-Y gastric bypass and relief of pre-existing symptoms. Abdominal pain should be part of follow-up consultations post Roux-en-Y gastric bypass. Future studies should focus on combined evaluations before and after surgery to enlighten potential casual relationships between abdominal pain and Roux-en-Y gastric bypass.

  19. Pre-test CFD Calculations for a Bypass Flow Standard Problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rich Johnson

    The bypass flow in a prismatic high temperature gas-cooled reactor (HTGR) is the flow that occurs between adjacent graphite blocks. Gaps exist between blocks due to variances in their manufacture and installation and because of the expansion and shrinkage of the blocks from heating and irradiation. Although the temperature of fuel compacts and graphite is sensitive to the presence of bypass flow, there is great uncertainty in the level and effects of the bypass flow. The Next Generation Nuclear Plant (NGNP) program at the Idaho National Laboratory has undertaken to produce experimental data of isothermal bypass flow between three adjacentmore » graphite blocks. These data are intended to provide validation for computational fluid dynamic (CFD) analyses of the bypass flow. Such validation data sets are called Standard Problems in the nuclear safety analysis field. Details of the experimental apparatus as well as several pre-test calculations of the bypass flow are provided. Pre-test calculations are useful in examining the nature of the flow and to see if there are any problems associated with the flow and its measurement. The apparatus is designed to be able to provide three different gap widths in the vertical direction (the direction of the normal coolant flow) and two gap widths in the horizontal direction. It is expected that the vertical bypass flow will range from laminar to transitional to turbulent flow for the different gap widths that will be available.« less

  20. Layer-by-Layer Templated Assembly of Silica at the Nanoscale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinestrosa, Juan Pablo; Sutton, Jonathan E.; Allison, David P.

    2013-01-29

    Bioinspired bottom-up assembly and layer-by-layer (LbL) construction of inorganic materials from lithographically defined organic templates enables the fabrication of nanostructured systems under mild temperature and pH conditions. Such processes open the door to low-impact manufacturing and facile recycling of hybrid materials for energy, biology, and information technologies. Here, templated LbL assembly of silica was achieved using a combination of electron beam lithography, chemical lift-off, and aqueous solution chemistry. Nanopatterns of lines, honeycomb-lattices, and dot arrays were defined in polymer resist using electron beam lithography. Following development, exposed areas of silicon were functionalized with a vapor deposited amine-silane monolayer. Silicic acidmore » solutions of varying pH and salt content were reacted with the patterned organic amine-functional templates. Vapor treatment and solution reaction could be repeated, allowing LbL deposition. Conditions for the silicic acid deposition had a strong effect on thickness of each layer, and the morphology of the amorphous silica formed. Defects in the arrays of silica nanostructures were minor and do not affect the overall organization of the layers. In conclusion, the bioinspired method described here facilitates the bottom-up assembly of inorganic nanostructures defined in three dimensions and provides a path, via LbL processing, for the construction of layered hybrid materials under mild conditions.« less

  1. Monsanto may bypass NIH in microbe test.

    PubMed

    Sun, Marjorie

    1985-01-11

    The Monsanto Company is planning to ask the Environmental Protection Agency for clearance to field test a genetically engineered microbial pesticide, bypassing the traditional approval process of the National Institutes of Health. Although only federally funded institutions are required to obtain NIH approval for genetic engineering tests, Monsanto is the first company to bypass the NIH regulatory process, which has become mired in a lawsuit brought by Jeremy Rifkin.

  2. Tunable and rapid self-assembly of block copolymers using mixed solvent vapors.

    PubMed

    Park, Woon Ik; Tong, Sheng; Liu, Yuzi; Jung, Il Woong; Roelofs, Andreas; Hong, Seungbum

    2014-12-21

    Pattern generation of well-controlled block copolymers (BCPs) with a high Flory-Huggins interaction parameter (χ) is important for applications in sub-20 nm nanolithography. We used mixed solvents of dimethylformamide (DMF) and toluene to control the morphology as well as the time to achieve the targeted morphology via self-assembly of BCPs. By precisely controlling the volume ratio of DMF and toluene, well-ordered line, honeycomb, circular hole, and lamellar nanostructures were obtained from a cylinder-forming poly(styrene-b-2-vinylpyridine) (PS-b-P2VP) BCP with high χ. Furthermore, a well-aligned 12 nm line pattern was successfully achieved in the guiding template within one minute using the mixed solvents. This practical method may also be applicable to self-assembly of other BCPs, providing more opportunities for the next-generation sub-10 nm lithography applications.

  3. An Experimental Design of Bypass Magneto-Rheological (MR) damper

    NASA Astrophysics Data System (ADS)

    Rashid, MM; Aziz, Mohammad Abdul; Raisuddin Khan, Md.

    2017-11-01

    The magnetorheological (MR) fluid bypass damper fluid flow through a bypass by utilizing an external channel which allows the controllability of MR fluid in the channel. The Bypass MR damper (BMRD) contains a rectangular bypass flow channel, current controlled movable piston shaft arrangement and MR fluid. The static piston coil case is winding by a coil which is used inside the piston head arrangement. The current controlled coil case provides a magnetic flux through the BMRD cylinder for controllability. The high strength of alloy steel materials are used for making piston shaft which allows magnetic flux propagation throughout the BMRD cylinder. Using the above design materials, a Bypass MR damper is designed and tested. An excitation of current is applied during the experiment which characterizes the BMRD controllability. It is shown that the BMRD with external flow channel allows a high controllable damping force using an excitation current. The experimental result of damping force-displacement characteristics with current excitation and without current excitation are compared in this research. The BMRD model is validated by the experimental result at various frequencies and applied excitation current.

  4. Aortocoronary bypass in Jehovah's Witnesses: review of 46 patients.

    PubMed

    Sandiford, F M

    1976-01-01

    The hemodilution technique for cardiopulmonary bypass using blood substitutes for priming has permitted open heart operations in Jehovah's Witnesses who refuse to accept blood, and has reduced the need for massive blood transfusion in certain procedures including aortocoronary bypass. A series of 46 Jehovah's Witness patients underwent aortocoronary bypass procedures. Of these, two patients died, representing a mortality of 4.3 per cent. Neither patient's death was related to lack of blood transfusions. The hospital stay and recovery time of all the other patients was not affected by failure to transfuse blood. The excellent short- and long-term results of this particular group paralleled those observed in our larger series of over 2700 other patients who have undergone coronary bypass surgery since 1969. Among these patients not of the Jehovah's Witness religion, blood transfusion was not necessary in about 30 per cent, while the remainder averaged less than two units per patient. Our results with Jehovah's Witness patients encourage our policy of avoiding blood transfusions whenever possible in all operations. Further justification for our conservative attitude is provided by the current shortage of blood in relation to a projected continuous increase of aortocoronary bypass procedures in the future.

  5. The combination of direct and paired link graphs can boost repetitive genome assembly

    PubMed Central

    Shi, Wenyu; Ji, Peifeng

    2017-01-01

    Abstract Currently, most paired link based scaffolding algorithms intrinsically mask the sequences between two linked contigs and bypass their direct link information embedded in the original de Bruijn assembly graph. Such disadvantage substantially complicates the scaffolding process and leads to the inability of resolving repetitive contig assembly. Here we present a novel algorithm, inGAP-sf, for effectively generating high-quality and continuous scaffolds. inGAP-sf achieves this by using a new strategy based on the combination of direct link and paired link graphs, in which direct link is used to increase graph connectivity and to decrease graph complexity and paired link is employed to supervise the traversing process on the direct link graph. Such advantage greatly facilitates the assembly of short-repeat enriched regions. Moreover, a new comprehensive decision model is developed to eliminate the noise routes accompanying with the introduced direct link. Through extensive evaluations on both simulated and real datasets, we demonstrated that inGAP-sf outperforms most of the genome scaffolding algorithms by generating more accurate and continuous assembly, especially for short repetitive regions. PMID:27924003

  6. Localized synthesis, assembly and integration of silicon nanowires

    NASA Astrophysics Data System (ADS)

    Englander, Ongi

    Localized synthesis, assembly and integration of one-dimensional silicon nanowires with MEMS structures is demonstrated and characterized in terms of local synthesis processes, electric-field assisted self-assembly, and a proof-of-concept nanoelectromechanical system (HEMS) demonstration. Emphasis is placed on the ease of integration, process control strategies, characterization techniques and the pursuit of integrated devices. A top-down followed by a bottom-up integration approach is utilized. Simple MEMS heater structures are utilized as the microscale platforms for the localized, bottom-up synthesis of one-dimensional nanostructures. Localized heating confines the high temperature region permitting only localized nanostructure synthesis and allowing the surroundings to remain at room temperature thus enabling CMOS compatible post-processing. The vapor-liquid-solid (VLS) process in the presence of a catalytic nanoparticle, a vapor phase reactant, and a specific temperature environment is successfully employed locally. Experimentally, a 5nm thick gold-palladium layer is used as the catalyst while silane is the vapor phase reactant. The current-voltage behavior of the MEMS structures can be correlated to the approximate temperature range required for the VLS reaction to take place. Silicon nanowires averaging 45nm in diameter and up to 29mum in length synthesized at growth rates of up to 1.5mum/min result. By placing two MEMS structures in close proximity, 4--10mum apart, localized silicon nanowire growth can be used to link together MEMS structures to yield a two-terminal, self-assembled micro-to-nano system. Here, one MEMS structure is designated as the hot growth structure while a nearby structure is designated as the cold secondary structure, whose role is to provide a natural stopping point for the VLS reaction. The application of a localized electric-field, 5 to 13V/mum in strength, during the synthesis process, has been shown to improve nanowire

  7. Long-term results of in situ saphenous vein bypass. Analysis of 2058 cases.

    PubMed Central

    Shah, D M; Darling, R C; Chang, B B; Fitzgerald, K M; Paty, P S; Leather, R P

    1995-01-01

    OBJECTIVE: The authors evaluated the long-term patency and outcome of patients undergoing infrainguinal reconstruction using the in situ saphenous vein. SUMMARY BACKGROUND DATA: The in situ saphenous vein bypass has demonstrated excellent patency and limb salvage rates in numerous studies. The authors previously reported their early results with these bypass procedures, and this article represents their long-term experience with 2058 in situ saphenous vein bypasses during a 20-year period. This comprises the largest series with long-term follow-up of in situ saphenous vein bypasses in the literature. METHODS: From 1975 to 1995, 3148 autogenous vein bypasses were performed at the authors' institution, of which 2058 used the saphenous vein in situ. The indication for operation was limb-threatening ischemia in 1875 of 2058 patients (91%). In 88% of patients with an intact ipsilateral saphenous vein, an in situ bypass was completed successfully. One thousand twenty-three bypasses (69%) were terminated at the infrapopliteal level. Of these bypasses, 1562 of 2058 (76%) were completed using the closed in situ technique. RESULTS: The 30-day patency rate was 96%, and the cumulative secondary patency was 91%, 81%, and 70% at 1, 5, and 10 years, respectively. Limb salvage rates using the in situ bypass were 97%, 95%, and 90% at 1, 5, and 10 years, respectively. CONCLUSION: The infrainguinal inflow source, length of bypass, specific outflow vessel, or vein diameter did not have a significant effect on immediate or long-term bypass performance. These data suggest that the in situ saphenous vein is an excellent conduit for femoropopliteal and femoral to infrageniculate bypasses for limb salvage. PMID:7574925

  8. Calibrated vapor generator source

    DOEpatents

    Davies, John P.; Larson, Ronald A.; Goodrich, Lorenzo D.; Hall, Harold J.; Stoddard, Billy D.; Davis, Sean G.; Kaser, Timothy G.; Conrad, Frank J.

    1995-01-01

    A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet.

  9. Calibrated vapor generator source

    DOEpatents

    Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

    1995-09-26

    A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

  10. Carotid artery bypass in acute postendarterectomy thrombosis.

    PubMed

    Paty, P S; Darling, R C; Cordero, J A; Shah, D M; Chang, B B; Leather, R P

    1996-08-01

    Carotid endarterectomy has demonstrated excellent results over the past 2 decades with combined stroke mortality of < 4% in most active centers. However, the optimal technique for surgical reconstruction for patients with acute postoperative deficits is more controversial. In the last 10 years (1985 to 1995), we performed 1,267 carotid endarterectomies, with 17 strokes (1.3%) and 16 deaths (1.2%). Twenty-four patients developed acute (within 72 hours) postoperative neurologic deficits. In 10 patients, the carotid artery was confirmed patent by duplex scan or angiography, and the neurologic deficit resolved without further therapy. Early reexploration was performed in 14 cases for suspected thrombosis associated with a new neurologic deficit. In each case, resection of the endarterectomy site and an interposition bypass was performed with greater saphenous vein (11), jugular vein (2), or polytetrafluoroethylene (2) grafts. (One patient required a new bypass for acute occlusion of the initial vein bypass.) Postoperatively, 8 patients had complete resolution of their deficit, 3 had minimal residual deficits, and 3 suffered permanent stroke. However, 2 of these patients died. Carotid artery bypass with exclusion of the endarterectomy site resulted in improvement in symptoms in 79% (11 of 14) of the patients and complete resolution in 57% (8 of 14). In long-term follow up (1 to 41 months), there have been no occlusions and one restenosis requiring revision at 11 months. Carotid artery bypass can be performed safely with acceptable results. The use of autogenous venous conduits allows reconstruction with an endothelial lined conduit that may improve results in patients with acute postoperative neurologic deficit secondary to thrombosis of the endarterectomized carotid artery.

  11. 21 CFR 870.4410 - Cardiopulmonary bypass in-line blood gas sensor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass in-line blood gas sensor... Cardiopulmonary bypass in-line blood gas sensor. (a) Identification. A cardiopulmonary bypass in-line blood gas sensor is a transducer that measures the level of gases in the blood. (b) Classification. Class II...

  12. 21 CFR 870.4410 - Cardiopulmonary bypass in-line blood gas sensor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass in-line blood gas sensor... Cardiopulmonary bypass in-line blood gas sensor. (a) Identification. A cardiopulmonary bypass in-line blood gas sensor is a transducer that measures the level of gases in the blood. (b) Classification. Class II...

  13. 21 CFR 870.4410 - Cardiopulmonary bypass in-line blood gas sensor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass in-line blood gas sensor... Cardiopulmonary bypass in-line blood gas sensor. (a) Identification. A cardiopulmonary bypass in-line blood gas sensor is a transducer that measures the level of gases in the blood. (b) Classification. Class II...

  14. 21 CFR 870.4410 - Cardiopulmonary bypass in-line blood gas sensor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass in-line blood gas sensor... Cardiopulmonary bypass in-line blood gas sensor. (a) Identification. A cardiopulmonary bypass in-line blood gas sensor is a transducer that measures the level of gases in the blood. (b) Classification. Class II...

  15. 21 CFR 870.4410 - Cardiopulmonary bypass in-line blood gas sensor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass in-line blood gas sensor... Cardiopulmonary bypass in-line blood gas sensor. (a) Identification. A cardiopulmonary bypass in-line blood gas sensor is a transducer that measures the level of gases in the blood. (b) Classification. Class II...

  16. VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eric M. Suuberg; Vahur Oja

    1997-07-01

    This project had as its main focus the determination of vapor pressures of coal pyrolysis tars. It involved performing measurements of these vapor pressures and from them, developing vapor pressure correlations suitable for use in advanced pyrolysis models (those models which explicitly account for mass transport limitations). This report is divided into five main chapters. Each chapter is a relatively stand-alone section. Chapter A reviews the general nature of coal tars and gives a summary of existing vapor pressure correlations for coal tars and model compounds. Chapter B summarizes the main experimental approaches for coal tar preparation and characterization whichmore » have been used throughout the project. Chapter C is concerned with the selection of the model compounds for coal pyrolysis tars and reviews the data available to us on the vapor pressures of high boiling point aromatic compounds. This chapter also deals with the question of identifying factors that govern the vapor pressures of coal tar model materials and their mixtures. Chapter D covers the vapor pressures and heats of vaporization of primary cellulose tars. Chapter E discusses the results of the main focus of this study. In summary, this work provides improved understanding of the volatility of coal and cellulose pyrolysis tars. It has resulted in new experimentally verified vapor pressure correlations for use in pyrolysis models. Further research on this topic should aim at developing general vapor pressure correlations for all coal tars, based on their molecular weight together with certain specific chemical characteristics i.e. hydroxyl group content.« less

  17. Quality of clinical care and bypassing of primary health centers in India.

    PubMed

    Rao, Krishna D; Sheffel, Ashley

    2018-06-01

    In many low and middle-income countries patients often bypass the nearest government health center offering free or subsidized services and seek more expensive care elsewhere. This study examines the role of quality of care, in particular clinician competence and structural quality of the health center, on bypassing behavior. Data for this study comes from a survey of 136 primary health centers (PHCs) and 3517 individuals living in the PHC's immediate vicinity in rural Chhattisgarh, India. Overall, the majority (67%) of patients bypassed the local PHC when seeking treatment. Bypassing decreased as provider competence increased, up to a point, after which, improvements in competency did not reduce bypassing. The clinical competence of the health care provider had a greater effect on reducing bypassing compared to PHC structural quality such as the building condition and drug stock-outs. However, the regular presence of clinical providers in the PHC was associated with lower bypassing. Patients that visited the local PHC spent half as much out-of-pocket as those that were treated at private clinics. Poor patients were less likely to bypass the local PHC compared to non-poor patients. These findings suggest that improving structural quality is not sufficient to reduce bypassing of PHCs. While better provider competency can substantially reduce bypassing, beyond a threshold competency level there is little effect. Efforts to strengthen facility-based primary care services need to go beyond simply focusing on improving infrastructure or quality of clinical care. There is a need to rethink how PHCs can be made more relevant to the health care needs of the communities they serve. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. The fidelity of synaptonemal complex assembly is regulated by a signaling mechanism that controls early meiotic progression.

    PubMed

    Silva, Nicola; Ferrandiz, Nuria; Barroso, Consuelo; Tognetti, Silvia; Lightfoot, James; Telecan, Oana; Encheva, Vesela; Faull, Peter; Hanni, Simon; Furger, Andre; Snijders, Ambrosius P; Speck, Christian; Martinez-Perez, Enrique

    2014-11-24

    Proper chromosome segregation during meiosis requires the assembly of the synaptonemal complex (SC) between homologous chromosomes. However, the SC structure itself is indifferent to homology, and poorly understood mechanisms that depend on conserved HORMA-domain proteins prevent ectopic SC assembly. Although HORMA-domain proteins are thought to regulate SC assembly as intrinsic components of meiotic chromosomes, here we uncover a key role for nuclear soluble HORMA-domain protein HTP-1 in the quality control of SC assembly. We show that a mutant form of HTP-1 impaired in chromosome loading provides functionality of an HTP-1-dependent checkpoint that delays exit from homology search-competent stages until all homolog pairs are linked by the SC. Bypassing of this regulatory mechanism results in premature meiotic progression and licensing of homology-independent SC assembly. These findings identify nuclear soluble HTP-1 as a regulator of early meiotic progression, suggesting parallels with the mode of action of Mad2 in the spindle assembly checkpoint. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Structural changes in Mcm5 protein bypass Cdc7-Dbf4 function and reduce replication origin efficiency in Saccharomyces cerevisiae.

    PubMed

    Hoang, Margaret L; Leon, Ronald P; Pessoa-Brandao, Luis; Hunt, Sonia; Raghuraman, M K; Fangman, Walton L; Brewer, Bonita J; Sclafani, Robert A

    2007-11-01

    Eukaryotic chromosomal replication is a complicated process with many origins firing at different efficiencies and times during S phase. Prereplication complexes are assembled on all origins in G(1) phase, and yet only a subset of complexes is activated during S phase by DDK (for Dbf4-dependent kinase) (Cdc7-Dbf4). The yeast mcm5-bob1 (P83L) mutation bypasses DDK but results in reduced intrinsic firing efficiency at 11 endogenous origins and at origins located on minichromosomes. Origin efficiency may result from Mcm5 protein assuming an altered conformation, as predicted from the atomic structure of an archaeal MCM (for minichromosome maintenance) homologue. Similarly, an intragenic mutation in a residue predicted to interact with P83L suppresses the mcm5-bob1 bypass phenotype. We propose DDK phosphorylation of the MCM complex normally results in a single, highly active conformation of Mcm5, whereas the mcm5-bob1 mutation produces a number of conformations, only one of which is permissive for origin activation. Random adoption of these alternate states by the mcm5-bob1 protein can explain both how origin firing occurs independently of DDK and why origin efficiency is reduced. Because similar mutations in mcm2 and mcm4 cannot bypass DDK, Mcm5 protein may be a unique Mcm protein that is the final target of DDK regulation.

  20. Patient Bypass Behavior and Critical Access Hospitals: Implications for Patient Retention

    ERIC Educational Resources Information Center

    Liu, Jiexin (Jason); Bellamy, Gail R.; McCormick, Melissa

    2007-01-01

    Purpose: To assess the extent of bypass for inpatient care among patients living in Critical Access Hospital (CAH) service areas, and to determine factors associated with bypass, the reasons for bypass, and what CAHs can do to retain patients locally. Methods: Six hundred and forty-seven subjects, aged 18 years and older, who had been admitted to…

  1. 21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cardiopulmonary bypass on-line blood gas monitor... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood...

  2. 21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cardiopulmonary bypass on-line blood gas monitor... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood...

  3. 21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cardiopulmonary bypass on-line blood gas monitor... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood...

  4. 21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass on-line blood gas monitor...

  5. 21 CFR 870.4330 - Cardiopulmonary bypass on-line blood gas monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Cardiopulmonary bypass on-line blood gas monitor. (a) Identification. A cardiopulmonary bypass on-line blood gas monitor is a device used in conjunction with a blood gas sensor to measure the level of gases in the blood... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass on-line blood gas monitor...

  6. Enthalpy of Vaporization and Vapor Pressures: An Inexpensive Apparatus

    ERIC Educational Resources Information Center

    Battino, Rubin; Dolson, David A.; Hall, Michael A.; Letcher, Trevor M.

    2007-01-01

    A simple and inexpensive method to determine the enthalpy of vaporization of liquids by measuring vapor pressure as a function of temperature is described. The vapor pressures measured with the stopcock cell were higher than the literature values and those measured with the sidearm rubber septum cell were both higher and lower than literature…

  7. Isolated Human Pulmonary Artery Structure and Function Pre- and Post-Cardiopulmonary Bypass Surgery.

    PubMed

    Dora, Kim A; Stanley, Christopher P; Al Jaaly, Emad; Fiorentino, Francesca; Ascione, Raimondo; Reeves, Barnaby C; Angelini, Gianni D

    2016-02-23

    Pulmonary dysfunction is a known complication after cardiac surgery using cardiopulmonary bypass, ranging from subclinical functional changes to prolonged postoperative ventilation, acute lung injury, and acute respiratory distress syndrome. Whether human pulmonary arterial function is compromised is unknown. The aim of the present study was to compare the structure and function of isolated and cannulated human pulmonary arteries obtained from lung biopsies after the chest was opened (pre-cardiopulmonary bypass) to those obtained at the end of cardiopulmonary bypass (post-cardiopulmonary bypass) from patients undergoing coronary artery bypass graft surgery. Pre- and post-cardiopulmonary bypass lung biopsies were received from 12 patients undergoing elective surgery. Intralobular small arteries were dissected, cannulated, pressurized, and imaged using confocal microscopy. Functionally, the thromboxane mimetic U46619 produced concentration-dependent vasoconstriction in 100% and 75% of pre- and post-cardiopulmonary bypass arteries, respectively. The endothelium-dependent agonist bradykinin stimulated vasodilation in 45% and 33% of arteries pre- and post-cardiopulmonary bypass, respectively. Structurally, in most arteries smooth muscle cells aligned circumferentially; live cell viability revealed that although 100% of smooth muscle and 90% of endothelial cells from pre-cardiopulmonary bypass biopsies had intact membranes and were considered viable, only 60% and 58%, respectively, were viable from post-cardiopulmonary bypass biopsies. We successfully investigated isolated pulmonary artery structure and function in fresh lung biopsies from patients undergoing heart surgery. Pulmonary artery contractile tone and endothelium-dependent dilation were significantly reduced in post-cardiopulmonary bypass biopsies. The decreased functional responses were associated with reduced cell viability. URL: http://www.isrctn.com/ISRCTN34428459. Unique identifier: ISRCTN 34428459.

  8. Airway bypass treatment of severe homogeneous emphysema: taking advantage of collateral ventilation.

    PubMed

    Choong, Cliff K; Cardoso, Paulo F G; Sybrecht, Gerhard W; Cooper, Joel D

    2009-05-01

    Airway bypass is being investigated as a new form of minimally invasive therapy for the treatment of homogeneous emphysema. It is a bronchoscopic catheter-based procedure that creates transbronchial extra-anatomic passages at the bronchial segmental level. The passages are expanded, supported with the expectation that the patency is maintained by paclitaxel drug-eluting airway bypass stents. The concept of airway bypass has been demonstrated in two separate experimental studies. These studies have shown that airway bypass takes advantage of collateral ventilation present in homogeneous emphysema to allow trapped gas to escape and reduce hyperinflation. It improves lung mechanics, expiratory flow, and volume. Airway bypass stent placements have been shown to be feasible and safe in both animal and human studies. Paclitaxel-eluting airway bypass stents were found to prolong stent patency and were adopted for clinical studies. A study evaluating the early results of the clinical application of airway bypass with paclitaxel-eluting stents found that airway bypass procedures reduced hyperinflation and improved pulmonary function and dyspnea in selected subjects who have severe emphysema. The duration of benefit appeared to correlate with the degree of pretreatment hyperinflation. These preliminary clinical results supported further evaluation of the procedure and led to the EASE Trial. The EASE Trial is a prospective, multicenter, randomized, double-blind, sham-controlled study. The trial aims to evaluate the safety and effectiveness of the airway bypass to improve pulmonary function and reduce dyspnea in homogeneous emphysema subjects who have severe hyperinflation. The trial is presently ongoing worldwide, though enrollment was completed.

  9. Thermal activation of dislocations in large scale obstacle bypass

    NASA Astrophysics Data System (ADS)

    Sobie, Cameron; Capolungo, Laurent; McDowell, David L.; Martinez, Enrique

    2017-08-01

    Dislocation dynamics simulations have been used extensively to predict hardening caused by dislocation-obstacle interactions, including irradiation defect hardening in the athermal case. Incorporating the role of thermal energy on these interactions is possible with a framework provided by harmonic transition state theory (HTST) enabling direct access to thermally activated reaction rates using the Arrhenius equation, including rates of dislocation-obstacle bypass processes. Moving beyond unit dislocation-defect reactions to a representative environment containing a large number of defects requires coarse-graining the activation energy barriers of a population of obstacles into an effective energy barrier that accurately represents the large scale collective process. The work presented here investigates the relationship between unit dislocation-defect bypass processes and the distribution of activation energy barriers calculated for ensemble bypass processes. A significant difference between these cases is observed, which is attributed to the inherent cooperative nature of dislocation bypass processes. In addition to the dislocation-defect interaction, the morphology of the dislocation segments pinned to the defects play an important role on the activation energies for bypass. A phenomenological model for activation energy stress dependence is shown to describe well the effect of a distribution of activation energies, and a probabilistic activation energy model incorporating the stress distribution in a material is presented.

  10. Advanced Raman water vapor lidar

    NASA Technical Reports Server (NTRS)

    Whiteman, David N.; Melfi, S. Harvey; Ferrare, Richard A.; Evans, Keith A.; Ramos-Izquierdo, Luis; Staley, O. Glenn; Disilvestre, Raymond W.; Gorin, Inna; Kirks, Kenneth R.; Mamakos, William A.

    1992-01-01

    Water vapor and aerosols are important atmospheric constituents. Knowledge of the structure of water vapor is important in understanding convective development, atmospheric stability, the interaction of the atmosphere with the surface, and energy feedback mechanisms and how they relate to global warming calculations. The Raman Lidar group at the NASA Goddard Space Flight Center (GSFC) developed an advanced Raman Lidar for use in measuring water vapor and aerosols in the earth's atmosphere. Drawing on the experience gained through the development and use of our previous Nd:YAG based system, we have developed a completely new lidar system which uses a XeF excimer laser and a large scanning mirror. The additional power of the excimer and the considerably improved optical throughput of the system have resulted in approximately a factor of 25 improvement in system performance for nighttime measurements. Every component of the current system has new design concepts incorporated. The lidar system consists of two mobile trailers; the first (13m x 2.4m) houses the lidar instrument, the other (9.75m x 2.4m) is for system control, realtime data display, and analysis. The laser transmitter is a Lambda Physik LPX 240 iCC operating at 400 Hz with a XeF gas mixture (351 nm). The telescope is a .75m horizontally mounted Dall-Kirkham system which is bore sited with a .8m x 1.1m elliptical flat which has a full 180 degree scan capability - horizon to horizon within a plane perpendicular to the long axis of the trailer. The telescope and scan mirror assembly are mounted on a 3.65m x .9m optical table which deploys out the rear of the trailer through the use of a motor driven slide rail system. The Raman returns from water vapor (403 nm), nitrogen (383 nm) and oxygen (372 nm) are measured in addition to the direct Rayleigh/Mie backscatter (351). The signal from each of these is split at about a 5/95 ratio between two photomultiplier detectors. The 5 percent detector is used for

  11. Smokers' rights to coronary artery bypass graft surgery.

    PubMed

    Heath, Janie; Braun, Mary Ann; Brindle, Margaret

    2002-06-01

    Imagine a health maintenance organization creating a policy to deny all smokers access to nonemergent coronary artery bypass graft surgery. The cost savings to the organization and society would be potentially significant. Now envision the smoker, a hardworking father with daily angina, and the provider, writing costly prescriptions to manage the angina. What ethical and legal questions do you suppose would present in that setting? Now imagine how you would respond if given this scenario of denying smokers access to nonemergent coronary artery bypass graft. This article discusses the implications of resource allocation with self-inflicted health behaviors such as smoking. Tough questions are raised that explore both the pros and the cons of smokers' rights to coronary artery bypass graft.

  12. Bypass flow computations on the LOFA transient in a VHTR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tung, Yu-Hsin; Johnson, Richard W.; Ferng, Yuh-Ming

    2014-01-01

    Bypass flow in the prismatic gas-cooled very high temperature reactor (VHTR) is not intentionally designed to occur, but is present in the gaps between graphite blocks. Previous studies of the bypass flow in the core indicated that the cooling provided by flow in the bypass gaps had a significant effect on temperature and flow distributions for normal operating conditions. However, the flow and heat transports in the core are changed significantly after a Loss of Flow Accident (LOFA). This study aims to study the effect and role of the bypass flow after a LOFA in terms of the temperature andmore » flow distributions and for the heat transport out of the core by natural convection of the coolant for a 1/12 symmetric section of the active core which is composed of images and mirror images of two sub-region models. The two sub-region models, 9 x 1/12 and 15 x 1/12 symmetric sectors of the active core, are employed as the CFD flow models using computational grid systems of 70.2 million and 117 million nodes, respectively. It is concluded that the effect of bypass flow is significant for the initial conditions and the beginning of LOFA, but the bypass flow has little effect after a long period of time in the transient computation of natural circulation.« less

  13. Petroleum Vapor Intrusion

    EPA Pesticide Factsheets

    One type of vapor intrusion is PVI, in which vapors from petroleum hydrocarbons such as gasoline, diesel, or jet fuel enter a building. Intrusion of contaminant vapors into indoor spaces is of concern.

  14. Genome wide interactions of wild-type and activator bypass forms of σ54

    PubMed Central

    Schaefer, Jorrit; Engl, Christoph; Zhang, Nan; Lawton, Edward; Buck, Martin

    2015-01-01

    Enhancer-dependent transcription involving the promoter specificity factor σ54 is widely distributed amongst bacteria and commonly associated with cell envelope function. For transcription initiation, σ54-RNA polymerase yields open promoter complexes through its remodelling by cognate AAA+ ATPase activators. Since activators can be bypassed in vitro, bypass transcription in vivo could be a source of emergent gene expression along evolutionary pathways yielding new control networks and transcription patterns. At a single test promoter in vivo bypass transcription was not observed. We now use genome-wide transcription profiling, genome-wide mutagenesis and gene over-expression strategies in Escherichia coli, to (i) scope the range of bypass transcription in vivo and (ii) identify genes which might alter bypass transcription in vivo. We find little evidence for pervasive bypass transcription in vivo with only a small subset of σ54 promoters functioning without activators. Results also suggest no one gene limits bypass transcription in vivo, arguing bypass transcription is strongly kept in check. Promoter sequences subject to repression by σ54 were evident, indicating loss of rpoN (encoding σ54) rather than creating rpoN bypass alleles would be one evolutionary route for new gene expression patterns. Finally, cold-shock promoters showed unusual σ54-dependence in vivo not readily correlated with conventional σ54 binding-sites. PMID:26082500

  15. Graft type for femoro-popliteal bypass surgery.

    PubMed

    Ambler, Graeme K; Twine, Christopher P

    2018-02-11

    Femoro-popliteal bypass is implemented to save limbs that might otherwise require amputation, in patients with ischaemic rest pain or tissue loss; and to improve walking distance in patients with severe life-limiting claudication. Contemporary practice involves grafts using autologous vein, polytetrafluoroethylene (PTFE) or Dacron as a bypass conduit. This is the second update of a Cochrane review first published in 1999 and last updated in 2010. To assess the effects of bypass graft type in the treatment of stenosis or occlusion of the femoro-popliteal arterial segment, for above- and below-knee femoro-popliteal bypass grafts. For this update, the Cochrane Vascular Information Specialist searched the Vascular Specialised Register (13 March 2017) and CENTRAL (2017, Issue 2). Trial registries were also searched. We included randomised trials comparing at least two different types of femoro-popliteal grafts for arterial reconstruction in patients with femoro-popliteal ischaemia. Randomised controlled trials comparing bypass grafting to angioplasty or to other interventions were not included. Both review authors (GKA and CPT) independently screened studies, extracted data, assessed trials for risk of bias and graded the quality of the evidence using GRADE criteria. We included nineteen randomised controlled trials, with a total of 3123 patients (2547 above-knee, 576 below-knee bypass surgery). In total, nine graft types were compared (autologous vein, polytetrafluoroethylene (PTFE) with and without vein cuff, human umbilical vein (HUV), polyurethane (PUR), Dacron and heparin bonded Dacron (HBD); FUSION BIOLINE and Dacron with external support). Studies differed in which graft types they compared and follow-up ranged from six months to 10 years.Above-knee bypassFor above-knee bypass, there was moderate-quality evidence that autologous vein grafts improve primary patency compared to prosthetic grafts by 60 months (Peto odds ratio (OR) 0.47, 95% confidence interval (CI

  16. Gastric bypass surgeries in New Hampshire, 1996-2007.

    PubMed

    Cherala, Sai S

    2012-01-01

    Obesity is a national epidemic. Gastric bypass surgery may be the only option that provides significant long-term weight loss for people who are morbidly obese (body mass index [BMI] ≥ 40 kg/m²) or for people who have a BMI of 35 or higher and have an obesity-related comorbidity. The objective of this study was to assess trends in gastric bypass surgery in New Hampshire. Data from 1996 to 2007 from the New Hampshire Inpatient Hospital Discharge data set were analyzed. Records for patients with a gastric bypass surgery code were identified, and data on patients and hospitalizations were collected. A joinpoint regression model was used to analyze trends in surgery rates. Differences between patients and payer types were analyzed by using the Cochran-Mantel-Haenszel χ² test. The annual rate of gastric bypass surgery increased significantly from 3.3 to 22.4 per 100,000 adults between 1996 and 2007. The in-hospital death rate decreased significantly from 11% in 1996 to 1% in 2007. A greater proportion of women (78.1% during the study period) than men had this surgery. The average charge of a surgery decreased significantly from $44,484 in 1996 to $43,907 in 2007; by 2007, total annual charges were $13.9 million. Since 1996, private or "other" payers have been charged for nearly 80% of the total discharges. The number of gastric bypass surgeries has increased in New Hampshire, and so have their cost. These increases may reflect a shortage in effective primary care and preventive measures to address the obesity epidemic.

  17. Experimental study on the performance of the vapor injection refrigeration system with an economizer for intermediate pressures

    NASA Astrophysics Data System (ADS)

    Moon, Chang-Uk; Choi, Kwang-Hwan; Yoon, Jung-In; Kim, Young-Bok; Son, Chang-Hyo; Ha, Soo-Jung; Jeon, Min-Ju; An, Sang-Young; Lee, Joon-Hyuk

    2018-04-01

    In this study, to investigate the performance characteristics of vapor injection refrigeration system with an economizer at an intermediate pressure, the vapor injection refrigeration system was analyzed under various experiment conditions. As a result, the optimum design data of the vapor injection refrigeration system with an economizer were obtained. The findings from this study can be summarized as follows. The mass flow rate through the compressor increases with intermediate pressure. The compression power input showed an increasing trend under all the test conditions. The evaporation capacity increased and then decreased at the intermediate pressure, and as such, it became maximum at the given intermediate pressure. The increased mass flow rate of the by-passed refrigerant enhanced the evaporation capacity at the low medium pressure range, but the increased saturation temperature limited the subcooling degree of the liquid refrigerant after the application of the economizer when the intermediate pressure kept rising, and degenerated the evaporation capacity. The coefficient of performance (COP) increased and then decreased with respect to the intermediate pressures under all the experiment conditions. Nevertheless, there was an optimum intermediate pressure for the maximum COP under each experiment condition. Therefore, the optimum intermediate pressure in this study was found at -99.08 kPa, which is the theoretical standard medium pressure under all the test conditions.

  18. Vapor phase pyrolysis

    NASA Technical Reports Server (NTRS)

    Steurer, Wolfgang

    1992-01-01

    The vapor phase pyrolysis process is designed exclusively for the lunar production of oxygen. In this concept, granulated raw material (soil) that consists almost entirely of metal oxides is vaporized and the vapor is raised to a temperature where it dissociates into suboxides and free oxygen. Rapid cooling of the dissociated vapor to a discrete temperature causes condensation of the suboxides, while the oxygen remains essentially intact and can be collected downstream. The gas flow path and flow rate are maintained at an optimum level by control of the pressure differential between the vaporization region and the oxygen collection system with the aid of the environmental vacuum.

  19. Bypass of a nick by the replisome of bacteriophage T7.

    PubMed

    Zhu, Bin; Lee, Seung-Joo; Richardson, Charles C

    2011-08-12

    DNA polymerase and DNA helicase are essential components of DNA replication. The helicase unwinds duplex DNA to provide single-stranded templates for DNA synthesis by the DNA polymerase. In bacteriophage T7, movement of either the DNA helicase or the DNA polymerase alone terminates upon encountering a nick in duplex DNA. Using a minicircular DNA, we show that the helicase · polymerase complex can bypass a nick, albeit at reduced efficiency of 7%, on the non-template strand to continue rolling circle DNA synthesis. A gap in the non-template strand cannot be bypassed. The efficiency of bypass synthesis depends on the DNA sequence downstream of the nick. A nick on the template strand cannot be bypassed. Addition of T7 single-stranded DNA-binding protein to the complex stimulates nick bypass 2-fold. We propose that the association of helicase with the polymerase prevents dissociation of the helicase upon encountering a nick, allowing the helicase to continue unwinding of the duplex downstream of the nick.

  20. Natural Product Screening Reveals Naphthoquinone Complex I Bypass Factors

    PubMed Central

    Mevers, Emily; Higgins, Kathleen W.; Fomina, Yevgenia; Zhang, Jianming; Mandinova, Anna; Newman, David; Shaw, Stanley Y.; Clardy, Jon; Mootha, Vamsi K.

    2016-01-01

    Deficiency of mitochondrial complex I is encountered in both rare and common diseases, but we have limited therapeutic options to treat this lesion to the oxidative phosphorylation system (OXPHOS). Idebenone and menadione are redox-active molecules capable of rescuing OXPHOS activity by engaging complex I-independent pathways of entry, often referred to as “complex I bypass.” In the present study, we created a cellular model of complex I deficiency by using CRISPR genome editing to knock out Ndufa9 in mouse myoblasts, and utilized this cell line to develop a high-throughput screening platform for novel complex I bypass factors. We screened a library of ~40,000 natural product extracts and performed bioassay-guided fractionation on a subset of the top scoring hits. We isolated four plant-derived 1,4-naphthoquinone complex I bypass factors with structural similarity to menadione: chimaphilin and 3-chloro-chimaphilin from Chimaphila umbellata and dehydro-α-lapachone and dehydroiso-α-lapachone from Stereospermum euphoroides. We also tested a small number of structurally related naphthoquinones from commercial sources and identified two additional compounds with complex I bypass activity: 2-methoxy-1,4-naphthoquinone and 2-methoxy-3-methyl-1,4,-naphthoquinone. The six novel complex I bypass factors reported here expand this class of molecules and will be useful as tool compounds for investigating complex I disease biology. PMID:27622560

  1. Outcomes of lower extremity bypass performed for acute limb ischemia

    PubMed Central

    Baril, Donald T.; Patel, Virendra I.; Judelson, Dejah R.; Goodney, Philip P.; McPhee, James T.; Hevelone, Nathanael D.; Cronenwett, Jack L.; Schanzer, Andres

    2013-01-01

    Objective Acute limb ischemia remains one of the most challenging emergencies in vascular surgery. Historically, outcomes following interventions for acute limb ischemia have been associated with high rates of morbidity and mortality. The purpose of this study was to determine contemporary outcomes following lower extremity bypass performed for acute limb ischemia. Methods All patients undergoing infrainguinal lower extremity bypass between 2003 and 2011 within hospitals comprising the Vascular Study Group of New England were identified. Patients were stratified according to whether or not the indication for lower extremity bypass was acute limb ischemia. Primary end points included bypass graft occlusion, major amputation, and mortality at 1 year postoperatively as determined by Kaplan-Meier life table analysis. Multivariable Cox proportional hazards models were constructed to evaluate independent predictors of mortality and major amputation at 1 year. Results Of 5712 lower extremity bypass procedures, 323 (5.7%) were performed for acute limb ischemia. Patients undergoing lower extremity bypass for acute limb ischemia were similar in age (66 vs 67; P = .084) and sex (68% male vs 69% male; P = .617) compared with chronic ischemia patients, but were less likely to be on aspirin (63% vs 75%; P < .0001) or a statin (55% vs 68%; P < .0001). Patients with acute limb ischemia were more likely to be current smokers (49% vs 39%; P < .0001), to have had a prior ipsilateral bypass (33% vs 24%; P = .004) or a prior ipsilateral percutaneous intervention (41% vs 29%; P = .001). Bypasses performed for acute limb ischemia were longer in duration (270 vs 244 minutes; P = .007), had greater blood loss (363 vs 272 mL; P < .0001), and more commonly utilized prosthetic conduits (41% vs 33%; P = .003). Acute limb ischemia patients experienced increased in-hospital major adverse events (20% vs 12%; P < .0001) including myocardial infarction, congestive heart failure exacerbation

  2. Outcomes of lower extremity bypass performed for acute limb ischemia.

    PubMed

    Baril, Donald T; Patel, Virendra I; Judelson, Dejah R; Goodney, Philip P; McPhee, James T; Hevelone, Nathanael D; Cronenwett, Jack L; Schanzer, Andres

    2013-10-01

    Acute limb ischemia remains one of the most challenging emergencies in vascular surgery. Historically, outcomes following interventions for acute limb ischemia have been associated with high rates of morbidity and mortality. The purpose of this study was to determine contemporary outcomes following lower extremity bypass performed for acute limb ischemia. All patients undergoing infrainguinal lower extremity bypass between 2003 and 2011 within hospitals comprising the Vascular Study Group of New England were identified. Patients were stratified according to whether or not the indication for lower extremity bypass was acute limb ischemia. Primary end points included bypass graft occlusion, major amputation, and mortality at 1 year postoperatively as determined by Kaplan-Meier life table analysis. Multivariable Cox proportional hazards models were constructed to evaluate independent predictors of mortality and major amputation at 1 year. Of 5712 lower extremity bypass procedures, 323 (5.7%) were performed for acute limb ischemia. Patients undergoing lower extremity bypass for acute limb ischemia were similar in age (66 vs 67; P = .084) and sex (68% male vs 69% male; P = .617) compared with chronic ischemia patients, but were less likely to be on aspirin (63% vs 75%; P < .0001) or a statin (55% vs 68%; P < .0001). Patients with acute limb ischemia were more likely to be current smokers (49% vs 39%; P < .0001), to have had a prior ipsilateral bypass (33% vs 24%; P = .004) or a prior ipsilateral percutaneous intervention (41% vs 29%; P = .001). Bypasses performed for acute limb ischemia were longer in duration (270 vs 244 minutes; P = .007), had greater blood loss (363 vs 272 mL; P < .0001), and more commonly utilized prosthetic conduits (41% vs 33%; P = .003). Acute limb ischemia patients experienced increased in-hospital major adverse events (20% vs 12%; P < .0001) including myocardial infarction, congestive heart failure exacerbation, deterioration in renal function

  3. Laparoscopic Conversion of One Anastomosis Gastric Bypass to a Standard Roux-en-Y Gastric Bypass.

    PubMed

    Amor, Imed Ben; Petrucciani, Niccolo; Kassir, Radwan; Al Munifi, Abdullah; Piche, Thierry; Debs, Tarek; Gugenheim, Jean

    2017-05-01

    One anastomosis gastric bypass (OAGB) demonstrated results similar to traditional Roux-en-Y procedures [1-3], in terms of weight loss and resolution of obesity-related comorbidities. The main controversy regarding OAGB is the concern for an association between biliary alkaline gastritis and esophageal or gastric cancer raised by some studies [4]. We present the case of a 51-year-old woman with a BMI of 41 kg/m2 who underwent a laparoscopic OAGB in 2014. One year later, she consulted for recurrent heartburns. An upper GI endoscopy showed pouchitis and bile reflux in the esophagus. Medical treatment of gastroesophageal reflux disease was ineffective. We decided to convert the OAGB to a Roux-en-Y gastric bypass (RYGB). In this video, we show how to revise an OAGB to treat chronic bile reflux, by converting the procedure to a standard RYGB. The intervention starts by restoring the normal anatomy of the small bowel, with the resection of the gastrojejunal anastomosis, which was located at 250-cm du Treitz's ligament. Then, the gastric pouch is created. A standard Roux-en-Y gastric bypass is performed. The resection of the gastrojejunal anastomosis allows fashioning the Roux-en-Y limb with the classical measures. This technique allows a conversion to a standard RYGB and is effective in treating the biliary reflux.

  4. Hemodynamic effect of bypass geometry on intracranial aneurysm: A numerical investigation.

    PubMed

    Kurşun, Burak; Uğur, Levent; Keskin, Gökhan

    2018-05-01

    Hemodynamic analyzes are used in the clinical investigation and treatment of cardiovascular diseases. In the present study, the effect of bypass geometry on intracranial aneurysm hemodynamics was investigated numerically. Pressure, wall shear stress (WSS) and velocity distribution causing the aneurysm to grow and rupture were investigated and the best conditions were tried to be determined in case of bypassing between basilar (BA) and left/right posterior arteries (LPCA/RPCA) for different values of parameters. The finite volume method was used for numerical solutions and calculations were performed with the ANSYS-Fluent software. The SIMPLE algorithm was used to solve the discretized conservation equations. Second Order Upwind method was preferred for finding intermediate point values in the computational domain. As the blood flow velocity changes with time, the blood viscosity value also changes. For this reason, the Carreu model was used in determining the viscosity depending on the velocity. Numerical study results showed that when bypassed, pressure and wall shear stresses reduced in the range of 40-70% in the aneurysm. Numerical results obtained are presented in graphs including the variation of pressure, wall shear stress and velocity streamlines in the aneurysm. Considering the numerical results for all parameter values, it is seen that the most important factors affecting the pressure and WSS values in bypassing are the bypass position on the basilar artery (L b ) and the diameter of the bypass vessel (d). Pressure and wall shear stress reduced in the range of 40-70% in the aneurysm in the case of bypass for all parameters. This demonstrates that pressure and WSS values can be greatly reduced in aneurysm treatment by bypassing in cases where clipping or coil embolization methods can not be applied. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Stress analysis method for clearance-fit joints with bearing-bypass loads

    NASA Technical Reports Server (NTRS)

    Naik, R. A.; Crews, J. H., Jr.

    1989-01-01

    Within a multi-fastener joint, fastener holes may be subjected to the combined effects of bearing loads and loads that bypass the hole to be reacted elsewhere in the joint. The analysis of a joint subjected to search combined bearing and bypass loads is complicated by the usual clearance between the hole and the fastener. A simple analysis method for such clearance-fit joints subjected to bearing-bypass loading has been developed in the present study. It uses an inverse formulation with a linear elastic finite-element analysis. Conditions along the bolt-hole contact arc are specified by displacement constraint equations. The present method is simple to apply and can be implemented with most general purpose finite-element programs since it does not use complicated iterative-incremental procedures. The method was used to study the effects of bearing-bypass loading on bolt-hole contact angles and local stresses. In this study, a rigid, frictionless bolt was used with a plate having the properties of a quasi-isotropic graphite/epoxy laminate. Results showed that the contact angle as well as the peak stresses around the hole and their locations were strongly influenced by the ratio of bearing and bypass loads. For single contact, tension and compression bearing-bypass loading had opposite effects on the contact angle. For some compressive bearing-bypass loads, the hole tended to close on the fastener leading to dual contact. It was shown that dual contact reduces the stress concentration at the fastener and would, therefore, increase joint strength in compression. The results illustrate the general importance of accounting for bolt-hole clearance and contact to accurately compute local bolt-hole stresses for combined bearings and bypass loading.

  6. Metabolic Profiles Predict Adverse Events Following Coronary Artery Bypass Grafting

    PubMed Central

    Shah, Asad A.; Craig, Damian M.; Sebek, Jacqueline K.; Haynes, Carol; Stevens, Robert C.; Muehlbauer, Michael J.; Granger, Christopher B.; Hauser, Elizabeth R.; Newby, L. Kristin; Newgard, Christopher B.; Kraus, William E.; Hughes, G. Chad; Shah, Svati H.

    2012-01-01

    Objectives Clinical models incompletely predict outcomes following coronary artery bypass grafting. Novel molecular technologies may identify biomarkers to improve risk stratification. We examined whether metabolic profiles can predict adverse events in patients undergoing coronary artery bypass grafting. Methods The study population comprised 478 subjects from the CATHGEN biorepository of patients referred for cardiac catheterization who underwent coronary artery bypass grafting after enrollment. Targeted mass spectrometry-based profiling of 69 metabolites was performed in frozen, fasting plasma samples collected prior to surgery. Principal-components analysis and Cox proportional hazards regression modeling were used to assess the relation between metabolite factor levels and a composite outcome of post-coronary artery bypass grafting myocardial infarction, need for percutaneous coronary intervention, repeat coronary artery bypass grafting, or death. Results Over a mean follow-up of 4.3 ± 2.4 years, 126 subjects (26.4%) suffered an adverse event. Three principal-components analysis-derived factors were significantly associated with adverse outcome in univariable analysis: short-chain dicarboxylacylcarnitines (factor 2, P=0.001); ketone-related metabolites (factor 5, P=0.02); and short-chain acylcarnitines (factor 6, P=0.004). These three factors remained independently predictive of adverse outcome after multivariable adjustment: factor 2 (adjusted hazard ratio 1.23; 95% confidence interval [1.10-1.38]; P<0.001), factor 5 (1.17 [1.01-1.37], P=0.04), and factor 6 (1.14 [1.02-1.27], P=0.03). Conclusions Metabolic profiles are independently associated with adverse outcomes following coronary artery bypass grafting. These profiles may represent novel biomarkers of risk that augment existing tools for risk stratification of coronary artery bypass grafting patients and may elucidate novel biochemical pathways that mediate risk. PMID:22306227

  7. Genome wide interactions of wild-type and activator bypass forms of σ54.

    PubMed

    Schaefer, Jorrit; Engl, Christoph; Zhang, Nan; Lawton, Edward; Buck, Martin

    2015-09-03

    Enhancer-dependent transcription involving the promoter specificity factor σ(54) is widely distributed amongst bacteria and commonly associated with cell envelope function. For transcription initiation, σ(54)-RNA polymerase yields open promoter complexes through its remodelling by cognate AAA+ ATPase activators. Since activators can be bypassed in vitro, bypass transcription in vivo could be a source of emergent gene expression along evolutionary pathways yielding new control networks and transcription patterns. At a single test promoter in vivo bypass transcription was not observed. We now use genome-wide transcription profiling, genome-wide mutagenesis and gene over-expression strategies in Escherichia coli, to (i) scope the range of bypass transcription in vivo and (ii) identify genes which might alter bypass transcription in vivo. We find little evidence for pervasive bypass transcription in vivo with only a small subset of σ(54) promoters functioning without activators. Results also suggest no one gene limits bypass transcription in vivo, arguing bypass transcription is strongly kept in check. Promoter sequences subject to repression by σ(54) were evident, indicating loss of rpoN (encoding σ(54)) rather than creating rpoN bypass alleles would be one evolutionary route for new gene expression patterns. Finally, cold-shock promoters showed unusual σ(54)-dependence in vivo not readily correlated with conventional σ(54) binding-sites. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  8. A remote augmentor lift system with a turbine bypass engine

    NASA Technical Reports Server (NTRS)

    Fishbach, L. H.; Franciscus, L. C.

    1982-01-01

    Two supersonic vertical takeoff or landing (VTOL) aircraft engine types, a conventional medium bypass ratio turbofan, and a turbine bypass turbojet were studied. The aircraft assumed was a clipped delta wing with canard configuration. A VTOL deck launched intercept, DLI, mission with Mach 1.6 dash and cruise segments was used as the design mission. Several alternate missions requiring extended subsonic capabilities were analyzed. Comparisons were made between the turbofan (TF) and the turbine bypass turbojet (TBE) engines in airplane types using a Remote Augmented Lift Systems, RALS and a Lift plus Lift Cruise system (L+LC). The figure of merit was takeoff gross weight for the VTOL DLI mission. The results of the study show that the turbine bypass turbojet and the conventional turbofan are competitive engines for both type of aircraft in terms of takeoff gross weight and range. However, the turbine bypass turbojet would be a simpler engine and may result in more attractive life cycle costs and reduced maintenance. The RALS and L+LC airplane types with either TBE or TF engines have approximately the same aircraft takeoff gross weight.

  9. Posttraumatic growth in post-surgical coronary artery bypass graft patients

    PubMed Central

    Waight, Catherine A; Sheridan, Judith; Tesar, Peter

    2015-01-01

    Recent research in posttraumatic growth has been applied to people with life-threatening illnesses to optimise recovery. There is a lack of research exploring posttraumatic growth in coronary artery bypass graft patients. This article describes the recovery experience of 14 coronary artery bypass graft patients (13 males and 1 female) at their first outpatient review post-surgery. Grounded theory analysis was used to develop a model of distinct and shared pathways to growth depending on whether patients were symptomatic or asymptomatic pre-coronary artery bypass graft. Outcomes of posttraumatic growth in this sample included action-based healthy lifestyle growth and two forms of cognitive growth: appreciation of life and new possibilities. The model of posttraumatic growth developed in this study may be helpful in guiding future research into promoting posttraumatic growth and behaviour change in coronary artery bypass graft patients. PMID:28070351

  10. Efficacy of aprotinin with various anticoagulant agents in cardiopulmonary bypass.

    PubMed

    Terrell, M R; Walenga, J M; Koza, M J; Pifarré, R

    1996-08-01

    Aprotinin has recently been approved for clinical use in cardiopulmonary bypass. Although unfractionated heparin has been the only anticoagulant widely used for cardiopulmonary bypass, disadvantages involving heparin have led to ongoing investigations of alternative anticoagulant agents. The objective of this study was to evaluate the efficacy of aprotinin in combination with other anticoagulant agents, specifically low molecular weight heparin and recombinant hirudin, using a dog model of cardiopulmonary bypass. The blood conservation resulting from the use of aprotinin was observed only with unfractionated heparin. Efficacy of anticoagulation as measured by protein deposits in the bypass circuit filter revealed an unexpected reduction in the quantity of deposits when aprotinin was used in combination with low molecular weight heparin. As alternative anticoagulant agents are sought, the potential benefits of aprotinin in the reduction of operative blood loss must be evaluated independently for each anticoagulant agent.

  11. 40 CFR 63.307 - Standards for bypass/bleeder stacks.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... National Emission Standards for Coke Oven Batteries § 63.307 Standards for bypass/bleeder stacks. (a)(1.... (2) Coke oven emissions shall not be vented to the atmosphere through bypass/bleeder stacks, except.... (3) The owner or operator of a brownfield coke oven battery or a padup rebuild shall install such a...

  12. 40 CFR 63.307 - Standards for bypass/bleeder stacks.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... National Emission Standards for Coke Oven Batteries § 63.307 Standards for bypass/bleeder stacks. (a)(1.... (2) Coke oven emissions shall not be vented to the atmosphere through bypass/bleeder stacks, except.... (3) The owner or operator of a brownfield coke oven battery or a padup rebuild shall install such a...

  13. 40 CFR 63.307 - Standards for bypass/bleeder stacks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... National Emission Standards for Coke Oven Batteries § 63.307 Standards for bypass/bleeder stacks. (a)(1.... (2) Coke oven emissions shall not be vented to the atmosphere through bypass/bleeder stacks, except.... (3) The owner or operator of a brownfield coke oven battery or a padup rebuild shall install such a...

  14. Aerodynamic/acoustic performance of YJ101/double bypass VCE with coannular plug nozzle

    NASA Technical Reports Server (NTRS)

    Vdoviak, J. W.; Knott, P. R.; Ebacker, J. J.

    1981-01-01

    Results of a forward Variable Area Bypass Injector test and a Coannular Nozzle test performed on a YJ101 Double Bypass Variable Cycle Engine are reported. These components are intended for use on a Variable Cycle Engine. The forward Variable Area Bypass Injector test demonstrated the mode shifting capability between single and double bypass operation with less than predicted aerodynamic losses in the bypass duct. The acoustic nozzle test demonstrated that coannular noise suppression was between 4 and 6 PNdB in the aft quadrant. The YJ101 VCE equipped with the forward VABI and the coannular exhaust nozzle performed as predicted with exhaust system aerodynamic losses lower than predicted both in single and double bypass modes. Extensive acoustic data were collected including far field, near field, sound separation/ internal probe measurements as Laser Velocimeter traverses.

  15. Directed-Assembly of Carbon Nanotubes on Soft Substrates for Flexible Biosensor Array

    NASA Astrophysics Data System (ADS)

    Lee, Hyoung Woo; Koh, Juntae; Lee, Byung Yang; Kim, Tae Hyun; Lee, Joohyung; Hong, Seunghun; Yi, Mihye; Jhon, Young Min

    2009-03-01

    We developed a method to selectively assemble and align carbon nanotubes (CNTs) on soft substrates for flexible biosensors. In this strategy, thin oxide layer was deposited on soft substrates via low temperature plasma enhanced chemical vapor deposition, and linker-free assembly process was applied onto the oxide surface where the assembly of carbon nanotubes was guided by methyl-terminated molecular patterns on the oxide surface. The electrical characterization of the fabricated CNT devices exhibited typical p-type gating effect and 1/f noise behavior. The bare oxide regions near CNTs were functionalized with glutamate oxidase to fabricate selective biosensors to detect two forms of glutamate substances existing in different situations: L-glutamic acid, a neuro-transmitting material, and monosodium glutamate, a food additive.

  16. Gastric bypass: why Roux-en-Y? A review of experimental data.

    PubMed

    Collins, Brendan J; Miyashita, Tomoharu; Schweitzer, Michael; Magnuson, Thomas; Harmon, John W

    2007-10-01

    To highlight the clinical and experimental rationales that support why the Roux-en-Y limb is an important surgical principle for bariatric gastric bypass. We reviewed PubMed citations for open Roux-en-Y gastric bypass (RYGBP), laparoscopic RYGBP, loop gastric bypass, chronic alkaline reflux gastritis, and duodenoesophageal reflux. We reviewed clinical and experimental articles. Clinical articles included prospective, retrospective, and case series of patients undergoing RYGBP, laparoscopic RYGBP, or loop gastric bypass. Experimental articles that were reviewed included in vivo and in vitro models of chronic duodenoesophageal reflux and its effect on carcinogenesis. No formal data extraction was performed. We reviewed published operative times, lengths of stay, and anastomotic leak rates for laparoscopic RYGBP and loop gastric bypass. For in vivo and in vitro experimental models of duodenoesophageal reflux, we reviewed the kinetics and potential molecular mechanisms of carcinogenesis. Recent data suggest that laparoscopic loop gastric bypass, performed without the creation of a Roux-en-Y gastroenterostomy, is a faster surgical technique that confers similarly robust weight loss compared with RYGBP or laparoscopic RYGBP. In the absence of a Roux limb, the long-term effects of chronic alkaline reflux are unknown. Animal models and in vitro analyses of chronic alkaline reflux suggest a carcinogenic effect.

  17. Protein Interactions in T7 DNA Replisome Facilitate DNA Damage Bypass.

    PubMed

    Zou, Zhenyu; Chen, Ze; Xue, Qizhen; Xu, Ying; Xiong, Jingyuan; Yang, Ping; Le, Shuai; Zhang, Huidong

    2018-06-14

    DNA replisome inevitably encounters DNA damage during DNA replication. T7 DNA replisome contains DNA polymerase (gp5), the processivity factor thioredoxin (trx), helicase-primase (gp4), and ssDNA binding protein (gp2.5). T7 protein interactions mediate this DNA replication. However, whether the protein interactions could promote DNA damage bypass is still little addressed. In this study, we investigated the strand-displacement DNA synthesis past 8-oxoG or O6-MeG at the synthetic DNA fork by T7 DNA replisome. DNA damage does not obviously affect the binding affinities among helicase, polymerase, and DNA fork. Relative to unmodified G, both 8-oxoG and O6-MeG, as well as GC-rich template sequence clusters, inhibit the strand-displacement DNA synthesis and produce partial extension products. Relative to gp4 ΔC-tail, gp4 promotes the DNA damage bypass. The presence of gp2.5 further promotes this bypass. Thus, the interactions of polymerase with helicase and ssDNA binidng protein faciliate the DNA damage bypass. Similarly, accessory proteins in other complicated DNA replisomes also facilitate the DNA damage bypass. This work provides the novel mechanism information of DNA damage bypass by DNA replisome. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Vapor Bubbles

    NASA Astrophysics Data System (ADS)

    Prosperetti, Andrea

    2017-01-01

    This article reviews the fundamental physics of vapor bubbles in liquids. Work on bubble growth and condensation for stationary and translating bubbles is summarized and the differences with bubbles containing a permanent gas stressed. In particular, it is shown that the natural frequency of a vapor bubble is proportional not to the inverse radius, as for a gas bubble, but to the inverse radius raised to the power 2/3. Permanent gas dissolved in the liquid diffuses into the bubble with strong effects on its dynamics. The effects of the diffusion of heat and mass on the propagation of pressure waves in a vaporous bubbly liquid are discussed. Other topics briefly touched on include thermocapillary flow, plasmonic nanobubbles, and vapor bubbles in an immiscible liquid.

  19. Reverse bias protected solar array with integrated bypass battery

    NASA Technical Reports Server (NTRS)

    Landis, Geoffrey A (Inventor)

    2012-01-01

    A method for protecting the photovoltaic cells in a photovoltaic (PV) array from reverse bias damage by utilizing a rechargeable battery for bypassing current from a shaded photovoltaic cell or group of cells, avoiding the need for a bypass diode. Further, the method mitigates the voltage degradation of a PV array caused by shaded cells.

  20. Travel burden and dentist bypass among dentally insured children.

    PubMed

    McKernan, Susan C; Pooley, Mark J; Momany, Elizabeth T; Kuthy, Raymond A

    2016-06-01

    Using administrative data from Iowa Medicaid and a large private dental insurer, we compared distance to the nearest primary care dentist for children ages 6-15 in 2012. Additionally, we examined rates of provider bypass in both populations as an indicator of spatial accessibility to dental care. We calculated measures of travel burden, including distance to the nearest primary care dentist and distance to current primary care dentist. Distance outcomes and rates of bypass, traveling beyond the nearest dentist for care, were compared by insurance type. We found that Medicaid-enrolled children lived farther from the nearest dentist and farther from their current dentist than privately insured children. However, rates of bypass were higher among the privately insured population. These results were consistent among urban and rural residents; additionally, both rural populations demonstrated greater travel distances than urban dwellers. Travel burden was greater among Medicaid-enrolled children. Lower rates of bypass, in conjunction with lower rates of dental utilization in this population, may indicate a distance threshold beyond which dental care becomes unattainable. © 2016 American Association of Public Health Dentistry.

  1. Vacuum vapor deposition

    NASA Technical Reports Server (NTRS)

    Poorman, Richard M. (Inventor); Weeks, Jack L. (Inventor)

    1995-01-01

    A method and apparatus is described for vapor deposition of a thin metallic film utilizing an ionized gas arc directed onto a source material spaced from a substrate to be coated in a substantial vacuum while providing a pressure differential between the source and the substrate so that, as a portion of the source is vaporized, the vapors are carried to the substrate. The apparatus includes a modified tungsten arc welding torch having a hollow electrode through which a gas, preferably inert, flows and an arc is struck between the electrode and the source. The torch, source, and substrate are confined within a chamber within which a vacuum is drawn. When the arc is struck, a portion of the source is vaporized and the vapors flow rapidly toward the substrate. A reflecting shield is positioned about the torch above the electrode and the source to ensure that the arc is struck between the electrode and the source at startup. The electrode and the source may be confined within a vapor guide housing having a duct opening toward the substrate for directing the vapors onto the substrate.

  2. Postoperative enlargement and prognostic effects of portal venous bypass grafts in children undergoing Rex shunt.

    PubMed

    Zhang, Jin-Shan; Li, Long; Cheng, Wei

    2018-05-22

    Patency of the bypass vein after a Rex shunt is an important indicator of prognosis. However, there is no report about the change of caliber of the bypass vein after a Rex shunt. The aim of this study was to identify postoperative changes of the bypass vein and to assess the relationship with prognosis. Between October 2008 and October 2016 in our center, 114 children were diagnosed with extrahepatic portal venous obstruction. The portal cavernoma-portal bypass with interposition of grafted portal vessels was performed in 31 children, the gastroportal shunt was performed in 54 children, and other Rex shunts were performed in another 29 children. At follow-up, the patency and diameter of the bypass vein were assessed with ultrasound and computed tomography. The intraoperative and postoperative diameters of the bypass vein were compared to identify postoperative changes of the bypass vein. Prognosis was compared between children with and children without an enlarged bypass vein. The caliber of the bypass vein was enlarged in 50% of children (40/80) at 6 months postoperatively. The postoperative incidences of rebleeding and esophageal varices were significantly lower in children with an enlarged bypass vein than in those without (P < .05). Postoperatively, the reduced splenic size was significantly higher in children with an enlarged bypass vein than in those without (P < .05). The postoperative increase in platelet count in children with an enlarged bypass vein was significantly higher than in those without (P = .006). There was no significant difference in the flow velocity of the bypass vein between children with and children without an enlarged bypass vein (P = .133). The portal pressure was significantly reduced after surgery in children with an enlarged bypass vein than in children without an enlarged bypass vein (P = .017). The caliber of the bypass vein increases in 50% of children after a Rex shunt using a grafted portal vessel, which is related to a

  3. Rankine cycle condenser pressure control using an energy conversion device bypass valve

    DOEpatents

    Ernst, Timothy C; Nelson, Christopher R; Zigan, James A

    2014-04-01

    The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.

  4. Sulforaphane pretreatment prevents systemic inflammation and renal injury in response to cardiopulmonary bypass.

    PubMed

    Nguyen, Bao; Luong, Le; Naase, Hatam; Vives, Marc; Jakaj, Gentjan; Finch, Jonathan; Boyle, Joseph; Mulholland, John W; Kwak, Jong-hwan; Pyo, Suhkneung; de Luca, Amalia; Athanasiou, Thanos; Angelini, Gianni; Anderson, Jon; Haskard, Dorian O; Evans, Paul C

    2014-08-01

    Systemic inflammatory responses are a major cause of morbidity and mortality in patients undergoing cardiac surgery with cardiopulmonary bypass. However, the underlying molecular mechanisms for systemic inflammation in response to cardiopulmonary bypass are poorly understood. A porcine model was established to study the signaling pathways that promote systemic inflammation in response to cardiac surgery with cardiopulmonary bypass under well-controlled experimental conditions. The influence of sulforaphane, an anti-inflammatory compound derived from green vegetables, on inflammation and injury in response to cardiopulmonary bypass was also studied. Intracellular staining and flow cytometry were performed to measure phosphorylation of p38 mitogen-activated protein kinase and the transcription factor nuclear factor-κB in granulocytes and mononuclear cells. Surgery with cardiopulmonary bypass for 1 to 2 hours enhanced phosphorylation of p38 (2.5-fold) and nuclear factor-κB (1.6-fold) in circulating mononuclear cells. Cardiopulmonary bypass also modified granulocytes by activating nuclear factor-κB (1.6-fold), whereas p38 was not altered. Histologic analyses revealed that cardiopulmonary bypass promoted acute tubular necrosis. Pretreatment of animals with sulforaphane reduced p38 (90% reduction) and nuclear factor-κB (50% reduction) phosphorylation in leukocytes and protected kidneys from injury. Systemic inflammatory responses after cardiopulmonary bypass were associated with activation of p38 and nuclear factor-κB pathways in circulating leukocytes. Inflammatory responses to cardiopulmonary bypass can be reduced by sulforaphane, which reduced leukocyte activation and protected against renal injury. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  5. Cost-utility analysis comparing laparoscopic vs open aortobifemoral bypass surgery.

    PubMed

    Krog, Anne Helene; Sahba, Mehdi; Pettersen, Erik M; Wisløff, Torbjørn; Sundhagen, Jon O; Kazmi, Syed Sh

    2017-01-01

    Laparoscopic aortobifemoral bypass has become an established treatment option for symptomatic aortoiliac obstructive disease at dedicated centers. Minimally invasive surgical techniques like laparoscopic surgery have often been shown to reduce expenses and increase patients' health-related quality of life. The main objective of our study was to measure quality-adjusted life years (QALYs) and costs after totally laparoscopic and open aortobifemoral bypass. This was a within trial analysis in a larger ongoing randomized controlled prospective multicenter trial, Norwegian Laparoscopic Aortic Surgery Trial. Fifty consecutive patients suffering from symptomatic aortoiliac occlusive disease suitable for aortobifemoral bypass surgery were randomized to either totally laparoscopic (n=25) or open surgical procedure (n=25). One patient dropped out of the study before surgery. We measured health-related quality of life using the EuroQol (EQ-5D-5L) questionnaire at 4 different time points, before surgery and for 6 months during follow-up. We calculated the QALYs gained by using the area under the curve for both groups. Costs were calculated based on prices for surgical equipment, vascular prosthesis and hospital stay. We found a significantly higher increase in QALYs after laparoscopic vs open aortobifemoral bypass surgery, with a difference of 0.07 QALYs, ( p =0.001) in favor of laparoscopic aortobifemoral bypass. The total cost of surgery, equipment and hospital stay after laparoscopic surgery (9,953 €) was less than open surgery (17,260 €), ( p =0.001). Laparoscopic aortobifemoral bypass seems to be cost-effective compared with open surgery, due to an increase in QALYs and lower procedure-related costs.

  6. Cerebroprotective effect of piracetam in patients undergoing coronary bypass burgery.

    PubMed

    Holinski, Sebastian; Claus, Benjamin; Alaaraj, Nour; Dohmen, Pascal Maria; Kirilova, Kremena; Neumann, Konrad; Uebelhack, Ralf; Konertz, Wolfgang

    2008-11-01

    Reduction of cognitive function is a possible side effect after cardiac surgery using cardiopulmonary bypass. We investigated the cerebroprotective effect of piracetam on cognitive performance in patients undergoing coronary artery bypass surgery under cardiopulmonary bypass. Patients scheduled for elective, primary and isolated coronary bypass surgery were randomised either to piracetam or placebo group. The study was performed in a double blind fashion. Patients received either 12 g piracetam or placebo at the beginning of the operation. Six neuropsychological subtests from the Syndrom Kurz Test and the Alzheimer's Disease Assessment Scale were performed preoperatively and on the third postoperative day. To assess the overall cognitive function and the degree of cognitive decline across all tests after surgery we combined the six test-scores by principal component analysis. A total number of 120 patients were enrolled into the study. Preoperative overall cognitive function were not significantly different between the groups. The postoperative combined score of the neuropsychological tests showed a deterioration of cognitive function in both groups (placebo-pre: -0.06+/-0.99 vs placebo-post: -1.38+/-1.11; p<0.0005 and piracetam-pre: 0.06+/-1.02 vs piracetam-post: -0.65+/-0.93; p<0.0005). However, the piracetam patients performed significantly better compared to the placebo patients after the operation and had a less decline of overall cognitive function (p<0.0005). Piracetam has a cerebroprotective effect in patients undergoing coronary artery bypass surgery with the use of cardiopulmonary bypass. It reduces an early postoperative substantial decline of neuropsychological abilities.

  7. Biliary bypass surgery - Analysis of indications & outcome of different procedures.

    PubMed

    Hussain Talpur, K Altaf; Mahmood Malik, Arshad; Iqbal Memon, Amir; Naeem Qureshi, Jawed; Khan Sangrasi, Ahmed; Laghari, Abdul Aziz

    2013-05-01

    This study reports the indications and outcome of various biliary bypass surgical procedures from a single centre over a period of 10 years. This is a prospective observational study conducted over a period of 10 years (January 2001-december 2010). A total of 1500 patients were included, who underwent pancreatico-biliary surgery due to common bile duct (CBD) stones, congenital anomalies of biliary tree, unoperable pancreatico-biliary malignancies, CBD strictures and cases who developed iatrogenic biliary injuries during cholecystectomy (both open & laproscopic) during this period of time. The patients who required biliary bypass surgery were further analysed for indications and outcome. Out of 1500 patients 83(5.53%) required biliary bypass surgical procedures. The CBD stones were observed as the most common indication (25.3%), followed by CBD injuries after open(10.84%) or laproscopic-cholecystectomy (14.46%), carcinoma head of pancreas (12.05%) and CBD obstruction(14.46%) either due to CBD strictures or unknown distal obstruction. Roux-en-Y-hepatico-jejunostomy (26.51%) was the most frequently performed procedure, followed by choledochoduodenostomy and Roux-en-Y choledocho-jejunostomy (i.e. 25.3% and 12.05% respectively). Roux-en-Y biliary bypass procedure was observed to be associated with better outcome in terms of rate of complications as well duration of hospital stay. Biliary bypass surgical procedures are the better options to restore the continuity of biliary system in patients with iatrogenic biliary tree injuries and un-operable pancreatico-biliary malignancy. Roux-en-Y biliary bypass procedure is safe and problem solving method in these cases.

  8. Probe for measurement of velocity and density of vapor in vapor plume

    DOEpatents

    Berzins, Leon V.; Bratton, Bradford A.; Fuhrman, Paul W.

    1997-01-01

    A probe which directs a light beam through a vapor plume in a first direction at a first angle ranging from greater than 0.degree. to less than 90.degree., reflecting the light beam back through the vapor plume at a 90.degree. angle, and then reflecting the light beam through the vapor plume a third time at a second angle equal to the first angle, using a series of mirrors to deflect the light beam while protecting the mirrors from the vapor plume with shields. The velocity, density, temperature and flow direction of the vapor plume may be determined by a comparison of the energy from a reference portion of the beam with the energy of the beam after it has passed through the vapor plume.

  9. Forensic investigation of concrete pavement : U.S. 460, Appomattox Bypass.

    DOT National Transportation Integrated Search

    2005-01-01

    This report describes the investigation of structural failure in a section of the Appomattox Bypass along U.S. 460 in the town of Appomattox, Virginia. The bypass is a four-lane divided highway. The section that was investigated is an 11-year-old sec...

  10. Bypass of a Nick by the Replisome of Bacteriophage T7*

    PubMed Central

    Zhu, Bin; Lee, Seung-Joo; Richardson, Charles C.

    2011-01-01

    DNA polymerase and DNA helicase are essential components of DNA replication. The helicase unwinds duplex DNA to provide single-stranded templates for DNA synthesis by the DNA polymerase. In bacteriophage T7, movement of either the DNA helicase or the DNA polymerase alone terminates upon encountering a nick in duplex DNA. Using a minicircular DNA, we show that the helicase·polymerase complex can bypass a nick, albeit at reduced efficiency of 7%, on the non-template strand to continue rolling circle DNA synthesis. A gap in the non-template strand cannot be bypassed. The efficiency of bypass synthesis depends on the DNA sequence downstream of the nick. A nick on the template strand cannot be bypassed. Addition of T7 single-stranded DNA-binding protein to the complex stimulates nick bypass 2-fold. We propose that the association of helicase with the polymerase prevents dissociation of the helicase upon encountering a nick, allowing the helicase to continue unwinding of the duplex downstream of the nick. PMID:21701044

  11. Vapor Intrusion

    EPA Pesticide Factsheets

    Vapor intrusion occurs when there is a migration of volatile chemicals from contaminated groundwater or soil into an overlying building. Volatile chemicals can emit vapors that may migrate through subsurface soils and into indoor air spaces.

  12. Rural health care bypass behavior: how community and spatial characteristics affect primary health care selection.

    PubMed

    Sanders, Scott R; Erickson, Lance D; Call, Vaughn R A; McKnight, Matthew L; Hedges, Dawson W

    2015-01-01

    (1) To assess the prevalence of rural primary care physician (PCP) bypass, a behavior in which residents travel farther than necessary to obtain health care, (2) To examine the role of community and non-health-care-related characteristics on bypass behavior, and (3) To analyze spatial bypass patterns to determine which rural communities are most affected by bypass. Data came from the Montana Health Matters survey, which gathered self-reported information from Montana residents on their health care utilization, satisfaction with health care services, and community and demographic characteristics. Logistic regression and spatial analysis were used to examine the probability and spatial patterns of bypass. Overall, 39% of respondents bypass local health care. Similar to previous studies, dissatisfaction with local health care was found to increase the likelihood of bypass. Dissatisfaction with local shopping also increases the likelihood of bypass, while the number of friends in a community, and commonality with community reduce the likelihood of bypass. Other significant factors associated with bypass include age, income, health, and living in a highly rural community or one with high commuting flows. Our results suggest that outshopping theory, in which patients bundle services and shopping for added convenience, extends to primary health care selection. This implies that rural health care selection is multifaceted, and that in addition to perceived satisfaction with local health care, the quality of local shopping and levels of community attachment also influence bypass behavior. © 2014 National Rural Health Association.

  13. Intraoperative sonographic assessment of graft patency during extracranial-intracranial bypass.

    PubMed

    Badie, B; Lee, F T; Pozniak, M A; Strother, C M

    2000-09-01

    Extracranial-intracranial (EC-IC) bypass may be necessary to facilitate treatment of unclippable posterior circulation fusiform aneurysms. Although intraoperative digital subtraction angiography (DSA) allows assessment of graft patency, this technique, because of difficulties inherent in performing selective catheterization and angiography in the operating room, has limitations. Duplex sonography, in contrast, is easily performed, and provides information regarding graft patency and blood flow direction during EC-IC bypass procedures. This latter information proved useful in determining the time of parent artery occlusion after two EC-IC bypass procedures performed for treatment of a fusiform midbasilar artery aneurysm.

  14. Cardiopulmonary bypass with bivalirudin in type II heparin-induced thrombocytopenia.

    PubMed

    Clayton, Stephanie B; Acsell, Jeffrey R; Crumbley, Arthur J; Uber, Walter E

    2004-12-01

    Cardiopulmonary bypass in patients with type II heparin induced-thrombocytopenia poses significant challenges. Inadequate pharmacokinetic profiles, monitoring, reversibility, and availability often limit alternative anticoagulation strategies. Bivalirudin, a semisynthetic direct thrombin inhibitor, was recently approved for use in patients undergoing percutaneous coronary interventions. Its unique properties, including a relatively short half-life, an anticoagulation effect that closely correlates with activated clotting time, and an alternate metabolic pathway for elimination, make bivalirudin an attractive agent for cardiopulmonary bypass in patients with type II heparin induced-thrombocytopenia. We report our experience using bivalirudin in 2 patients undergoing coronary artery bypass grafting.

  15. Role of cytokine hemoadsorption in cardiopulmonary bypass-induced ventricular dysfunction in a porcine model.

    PubMed

    Vocelka, Craig R; Jones, Krystal M; Mikhova, Krasimira M; Ebisu, Ryan M; Shar, Ashley; Kellum, John A; Verrier, Edward D; Rabkin, David G

    2013-12-01

    Little is known about the effect of cardiopulmonary bypass alone on cardiac function; in an attempt to illuminate this relationship and test a possible mechanism, we used Cytosorb, a device capable of removing virtually all types of circulating cytokines to test the hypothesis that hemoadsorption of cytokines during bypass attenuates bypass-induced acute organ dysfunction. Twelve Yorkshire pigs (50-65 kg) were instrumented with a left ventricular conductance catheter. Baseline mechanics and cytokine expression (tumor necrosis factor [TNF], interleukin-6 [IL-6], and interleukin-10) were measured before and hourly after 1 hour of normothermic cardiopulmonary bypass. Animals underwent bypass without (cardiopulmonary bypass [CPB], n = 6) or with (CPB+HA, n = 6) the CytosorbTM device. Data were compared with "historical" controls (n = 6) that were similarly instrumented but underwent observation instead of bypass. Five hours after separation from bypass (or observation), animals were euthanized. Myocardial water content was determined postmortem. Neither TNF nor IL-6 was significantly elevated in either experimental group versus controls at any time point. Preload recruitable stroke work and dP/dtmax were significantly depressed immediately after separation from bypass in both CPB+HA and CPB and remained depressed for the duration of the experiment. Although Tau remained unchanged, dP/dTmin was significantly diminished in both bypass groups at all time points after separation from bypass. Cytokine hemoadsorption had no effect on any measurable index of function. Differences in postmortem data were not evident between groups. One hour of normothermic CPB results in a significant and sustained decline in left ventricular function that appears unrelated to changes in cytokine expression. Because we did not appreciate a significant change in cytokine concentrations postbypass, the capacity of cytokine hemoadsorption to attenuate CPB-induced ventricular dysfunction could not

  16. Active bypass flow control for a seal in a gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebert, Todd A.; Kimmel, Keith D.

    An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wears.more » In at least one embodiment, the metering device may include a valve formed from one or more pins movable between open and closed positions in which the one pin at least partially bisects the bypass channel to regulate flow.« less

  17. Heart bypass surgery - minimally invasive - discharge

    MedlinePlus

    ... thrombosis, 9th ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest . 2012;141(2 ... bypass surgery - minimally invasive Heart failure - overview High blood cholesterol ...

  18. Probe for measurement of velocity and density of vapor in vapor plume

    DOEpatents

    Berzins, L.V.; Bratton, B.A.; Fuhrman, P.W.

    1997-03-11

    A probe is disclosed which directs a light beam through a vapor plume in a first direction at a first angle ranging from greater than 0{degree} to less than 90{degree}, reflecting the light beam back through the vapor plume at a 90{degree} angle, and then reflecting the light beam through the vapor plume a third time at a second angle equal to the first angle, using a series of mirrors to deflect the light beam while protecting the mirrors from the vapor plume with shields. The velocity, density, temperature and flow direction of the vapor plume may be determined by a comparison of the energy from a reference portion of the beam with the energy of the beam after it has passed through the vapor plume. 10 figs.

  19. Is phonology bypassed in normal or dyslexic development?

    PubMed

    Pennington, B F; Lefly, D L; Van Orden, G C; Bookman, M O; Smith, S D

    1987-01-01

    A pervasive assumption in most accounts of normal reading and spelling development is that phonological coding is important early in development but is subsequently superseded by faster, orthographic coding which bypasses phonology. We call this assumption, which derives from dual process theory, the developmental bypass hypothesis. The present study tests four specific predictions of the developmental bypass hypothesis by comparing dyslexics and nondyslexics from the same families in a cross-sectional design. The four predictions are: 1) That phonological coding skill develops early in normal readers and soon reaches asymptote, whereas orthographic coding skill has a protracted course of development; 2) that the correlation of adult reading or spelling performance with phonological coding skill is considerably less than the correlation with orthographic coding skill; 3) that dyslexics who are mainly deficient in phonological coding skill should be able to bypass this deficit and eventually close the gap in reading and spelling performance; and 4) that the greatest differences between dyslexics and developmental controls on measures of phonological coding skill should be observed early rather than late in development.None of the four predictions of the developmental bypass hypothesis were upheld. Phonological coding skill continued to develop in nondyslexics until adulthood. It accounted for a substantial (32-53 percent) portion of the variance in reading and spelling performance in adult nondyslexics, whereas orthographic coding skill did not account for a statistically reliable portion of this variance. The dyslexics differed little across age in phonological coding skill, but made linear progress in orthographic coding skill, surpassing spelling-age (SA) controls by adulthood. Nonetheless, they didnot close the gap in reading and spelling performance. Finally, dyslexics were significantly worse than SA (and Reading Age [RA]) controls in phonological coding skill

  20. Comparative effectiveness of anticoagulation on midterm infrainguinal bypass graft patency.

    PubMed

    Liang, Nathan L; Baril, Donald T; Avgerinos, Efthymios D; Leers, Steven A; Makaroun, Michel S; Chaer, Rabih A

    2017-08-01

    Therapeutic anticoagulation (AC) is used clinically for prolongation of infrainguinal bypass patency, but evidence for the efficacy of this practice is conflicting. The objective of our study was to determine the association of AC with bypass graft primary patency. Clinical and comorbid data of patients undergoing infrainguinal bypass grafts to a below-knee target with at least 1 year of follow-up performed from 2003 to 2015 were obtained from the Society for Vascular Surgery Vascular Quality Initiative. Inverse propensity of treatment-weighted Cox regression was used to assess the effect of AC on patency in the total cohort while adjusting for clinical, operative, and comorbid differences between treatment groups. Subgroup analyses of distal targets and conduit type were performed. Perioperative complications were analyzed using propensity-weighted logistic regression. We identified 7612 bypass grafts with intact 1-year follow-up information from 2003 to 2015. The mean age was 67.5 ± 11.2 years; 30.5% (n = 2320) were female, and 28.6% (n = 2165) were discharged on therapeutic AC. The anticoagulated group had a higher rate of tibial, ankle, and pedal targets (52.1% [n = 1127] vs 47.6% [n = 2269]; P < .001), had a greater use of non-single-segment vein conduits (44.3% [n = 951] vs 26.5% [n = 1426]; P < .001), and was more likely to have had a previous ipsilateral bypass (27.2% [n = 589] vs 14.7% [n = 794]; P < .001) or stent (25.4% [n = 550] vs 20.9% [n = 1130]; P < .001). Estimated unadjusted primary patency was 70.8% ± 0.6% at 1 year and lower for anticoagulated bypasses (66.9% ± 1.2% vs 72.4% ± 0.7%; P < .001). Propensity-weighted analysis showed no significant association of AC with primary patency in the overall cohort (hazard ratio [HR], 0.98; 95% confidence interval [CI], 0.86-1.11; P = .8) but demonstrated a trend toward improvement of primary patency in those with a non-single-segment vein conduit to a below-knee popliteal target

  1. Femorofemoral bypass grafting in high-risk patients.

    PubMed

    Deruyter, L; Caes, F; Van den Brande, P; Cham, B; Welch, W

    1986-01-01

    A total of 37 extra-anatomic femorofemoral bypasses were inserted for severe unilateral iliac artery stenosis or a thrombosed graft limb of an aorto-bifemoral bifurcation graft. All patients were severely debilitated and at high risk for direct aorto-iliac reconstruction. 30% suffered severe claudication; 70% had ischemic restpain or trophic lesions. 43% died during a mean follow-up period of 17 months. This study demonstrates that the extra-anatomic femoro-femoral bypass procedure is an effective alternative therapeutic modality for high-risk patients with an acceptable operative mortality (5.4%) and morbidity to improve the quality of life.

  2. Esophageal bypass operation prior to definitive chemoradiotherapy in advanced esophageal cancer with tracheobronchial invasion.

    PubMed

    Hihara, Jun; Hamai, Yoichi; Emi, Manabu; Aoki, Yoshiro; Taomoto, Junya; Miyata, Yoshihiro; Okada, Morihito

    2014-01-01

    In T4 esophageal cancer with tracheobronchial invasion, an esophagorespiratory fistula (ERF) often occurs during or after chemoradiotherapy. We have performed esophageal bypass operations prior to definitive chemoradiotherapy for these patients to increase the chemoradiotherapy completion rate by minimizing the potential effect of an ERF. The aim of this study was to examine the clinical outcome of esophageal bypass surgery prior to chemoradiotherapy. Between 1997 and 2010, 17 patients underwent esophageal bypass surgery followed by definitive chemoradiotherapy for esophageal cancer with tracheobronchial invasion (bypass group). Ten patients in the same circumstances were treated with chemoradiotherapy alone (control group). Overall survival, the clinical effect of chemoradiotherapy, the ERF incidence rate, and the safety of esophageal bypass surgery were assessed. The overall response rate to chemoradiotherapy was 64.7% in the bypass group and 90.0% in the control group. Except for 2 patients with ERF at initial diagnosis, 4 (26.7%) of the 15 patients developed ERF in the bypass group, and 3 (30.0%) of the 10 patients developed ERF in the control group during or after chemoradiotherapy. The 2-year and 3-year overall survival rates were 17.6% and 17.6% in the bypass group and 20.0% and 0% in the control group, respectively (p = 0.924); long-term survival of more than 3 years was seen only in the bypass group. Esophageal bypass surgery prior to definitive chemoradiotherapy could be performed safely, and this strategy contributed to long-term survival in the patients who achieved a good response to chemoradiotherapy but developed an ERF. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Cost-utility analysis comparing laparoscopic vs open aortobifemoral bypass surgery

    PubMed Central

    Krog, Anne Helene; Sahba, Mehdi; Pettersen, Erik M; Wisløff, Torbjørn; Sundhagen, Jon O; Kazmi, Syed SH

    2017-01-01

    Objectives Laparoscopic aortobifemoral bypass has become an established treatment option for symptomatic aortoiliac obstructive disease at dedicated centers. Minimally invasive surgical techniques like laparoscopic surgery have often been shown to reduce expenses and increase patients’ health-related quality of life. The main objective of our study was to measure quality-adjusted life years (QALYs) and costs after totally laparoscopic and open aortobifemoral bypass. Patients and methods This was a within trial analysis in a larger ongoing randomized controlled prospective multicenter trial, Norwegian Laparoscopic Aortic Surgery Trial. Fifty consecutive patients suffering from symptomatic aortoiliac occlusive disease suitable for aortobifemoral bypass surgery were randomized to either totally laparoscopic (n=25) or open surgical procedure (n=25). One patient dropped out of the study before surgery. We measured health-related quality of life using the EuroQol (EQ-5D-5L) questionnaire at 4 different time points, before surgery and for 6 months during follow-up. We calculated the QALYs gained by using the area under the curve for both groups. Costs were calculated based on prices for surgical equipment, vascular prosthesis and hospital stay. Results We found a significantly higher increase in QALYs after laparoscopic vs open aortobifemoral bypass surgery, with a difference of 0.07 QALYs, (p=0.001) in favor of laparoscopic aortobifemoral bypass. The total cost of surgery, equipment and hospital stay after laparoscopic surgery (9,953 €) was less than open surgery (17,260 €), (p=0.001). Conclusion Laparoscopic aortobifemoral bypass seems to be cost-effective compared with open surgery, due to an increase in QALYs and lower procedure-related costs. PMID:28670132

  4. Heart bypass surgery - minimally invasive

    MedlinePlus

    ... MIDCAB; Robot-assisted coronary artery bypass; RACAB; Keyhole heart surgery; CAD - MIDCAB; Coronary artery disease - MIDCAB ... To perform this surgery: The heart surgeon will make a 3- to 5-inch (8 to 13 centimeters) surgical cut in the left part of your chest ...

  5. BTSC VAPOR INSTRUSION PRIMER "VAPOR INTRUSION CONSIDERATION FOR REDEVELOPMENT"

    EPA Science Inventory

    This primer is designed for brownfields stakeholders concerned about vapor intrusion, including property owners, real estate developers, and contractors performing environmental site investigations. It provides an overview of the vapor intrusion issue and how it can impact the ap...

  6. Bypass transition in boundary layers including curvature and favorable pressure gradient effects

    NASA Technical Reports Server (NTRS)

    Volino, R. J.; Simon, T. W.

    1991-01-01

    Recent studies of 2-D boundary layers undergoing bypass transition were reviewed. Bypass transition is characterized by the sudden appearance of turbulent spots in boundary layer without first the regular, observable growth of disturbances predicted by linear stability theory. There are no standard criteria or parameters for defining bypass transition, but it is known to be the mode of transition when the flow is disturbed by perturbations of sufficient amplitude.

  7. Temporary diabetes insipidus in 2 men after on-pump coronary artery bypass grafting.

    PubMed

    Uyar, Ihsan Sami; Sahin, Veysel; Akpinar, Besir; Yurtman, Volkan; Abacilar, Feyzi; Okur, Faik Fevzi; Ates, Mehmet

    2013-01-01

    Many complications have been reported after cardiopulmonary bypass. A common physiologic change during the early postoperative period after cardiopulmonary bypass is increased diuresis. In patients whose urine output is increased, postoperative diabetes insipidus can develop, although reports of this are rare. We present the cases of 2 patients who underwent on-pump coronary artery bypass grafting (with cardiopulmonary bypass). Each was diagnosed with diabetes insipidus postoperatively: a 54-year-old man on the 3rd day, and a 66-year-old man on the 4th day. Each patient recovered from the condition after 6 hours of intranasal therapy with synthetic vasopressin (antidiuretic hormone). The diagnosis of diabetes insipidus should be considered in patients who produce excessive urine early after cardiac surgery in which cardiopulmonary bypass has been used.

  8. The Golden bypass landslide, Golden, Colorado

    USGS Publications Warehouse

    Highland, L.M.; Brown, W. M.

    1993-01-01

    Slope instability along a new highway bypass in Golden, Colorado, became a major concern in 1993. Rains and snowmelt accelerated movement of a landslide that had begun to develop before the bypass was opened to traffic in July of 1991. The downslope movement of earth materials increased significantly in 1993. During the first few months of the year, the landslide pushed onto the west shoulder of the road and crumpled the pavement beneath the south-bound lane. As we prepare this article (September, 1993), the slide continues to encroach onto the highway, posing a persistent problem despite repeated efforts to slow or stop its movement. As this article will show, permanent solutions to landslide problems of this kind are difficult to obtain. 

  9. Outcomes of Mini vs Roux-en-Y gastric bypass: A meta-analysis and systematic review.

    PubMed

    Wang, Fu-Gang; Yan, Wen-Mao; Yan, Ming; Song, Mao-Min

    2018-05-10

    Mini gastric bypass has been proved to be capable of achieving excellent metabolic results by numerous published studies. Compared to Roux-en-Y gastric bypass, mini gastric bypass is a technically simpler and reversible procedure. However, comparative outcomes of the effectiveness between Mini gastric bypass and Roux-en-Y gastric bypass remain unclear. A systematic literature search was performed in Pubmed, Embase, Cochrane library from inception to February 9, 2018. For assessment of method quality, NOS (Newcastle-Ottawa Scale) and Cochrane Collaboration's tool for assessing risk of bias were used for cohort study and randomized controlled trials, respectively. The meta-analysis was performed by RevMan 5.3 software. 10 cohort studies and 1 randomized controlled trial was included in our meta-analysis. The method quality of the 10 cohort studies was proved as high quality according to the Newcastle-Ottawa Scale. The randomized controlled trial was proved to have a low risk of bias according to Cochrane Collaboration's assessment. Patients receiving mini-gastric bypass had multiple advantageous indexes as compared with patients receiving Roux-en-Y gastric bypass. Examples include: a higher 1-year EWL% (P < 0.05), higher 2-year EWL% (P < 0.05), higher type 2 diabetes mellitus remission rate, as well as a shorter operation time (P < 0.05). No significant statistical difference was observed in hypertension remission rate, mortality, leakage rate, GERD rate, or hospital stay between mini gastric bypass and Roux-en-Y gastric bypass. Mini gastric bypass seems to be a simpler procedure with a better weight reduction effect. This seems to also be the case regarding remission rates of type 2 diabetes mellitus when using Mini gastric bypass in comparison to Roux-en-Y gastric bypass. A small sample size and biased data may have influenced the stability of our results. In light of this, surgeons should treat our results in a conservative way. Larger sample size and

  10. Health and performance of calves with forestomach-bypass fed milk replacer.

    PubMed

    McKinstry, D M; Cason, J L; Albert, T F; Sass, B

    1976-02-01

    Ten male Holstein calves were placed in groups of two calves each on similarity of age. On calf in each group was subjected to forestomach-bypass surgery at about 1 mo of age. Fortified commercial milk replacer with added minerals and vitamins was fed as the sole diet. The calves were housed indoors on slatted platforms. Weight gain was determined biweekly. Feed intake was determined daily. Necropsies were performed upon termination of the study. Recurrent ruminal bloat, fever, and anorexia of varying degrees and combinations occurred in four of the calves with forestomach bypass. Two of these calves showed slow weight gain. One of the four calves died following acute bloat while the other three calves were sacrificed following repeated episodes of bloat. The time of termination varied between 3 and 10 mo. One calf with forestomach bypass and all control calves appeared healthy throughout the experiment. Necropsies indicated that the ruminal bloat, seen in most of the forestomach-bypass calves, could be attributed to the back-flow of ingesta via the omasal-abomasal orifice. This ingesta appeared to produce gas which became trapped in the bypassed rumen.

  11. Multislice Computed Tomography Accurately Detects Stenosis in Coronary Artery Bypass Conduits

    PubMed Central

    Duran, Cihan; Sagbas, Ertan; Caynak, Baris; Sanisoglu, Ilhan; Akpinar, Belhhan; Gulbaran, Murat

    2007-01-01

    The aim of this study was to evaluate the accuracy of multislice computed tomography in detecting graft stenosis or occlusion after coronary artery bypass grafting, using coronary angiography as the standard. From January 2005 through May 2006, 25 patients (19 men and 6 women; mean age, 54 ± 11.3 years) underwent diagnostic investigation of their bypass grafts by multislice computed tomography within 1 month of coronary angiography. The mean time elapsed after coronary artery bypass grafting was 6.2 years. In these 25 patients, we examined 65 bypass conduits (24 arterial and 41 venous) and 171 graft segments (the shaft, proximal anastomosis, and distal anastomosis). Compared with coronary angiography, the segment-based sensitivity, specificity, and positive and negative predictive values of multislice computed tomography in the evaluation of stenosis were 89%, 100%, 100%, and 99%, respectively. The patency rate for multislice compu-ted tomography was 85% (55/65: 3 arterial and 7 venous grafts were occluded), with 100% sensitivity and specificity. From these data, we conclude that multislice computed tomography can accurately evaluate the patency and stenosis of bypass grafts during outpatient follow-up. PMID:17948078

  12. Investigation of bypass fluid flow in an active magnetic regenerative liquefier

    DOE PAGES

    Holladay, Jamelyn; Teyber, Reed; Meinhardt, Kerry; ...

    2018-05-19

    Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass imbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a functionmore » of the bypass flow fraction. In conclusion, experiments are performed at a fixed temperature span yielding a 30% improvement in net cooling power, affirming the potential of bypass flow in active magnetic regenerative liquefiers.« less

  13. Investigation of bypass fluid flow in an active magnetic regenerative liquefier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holladay, Jamelyn; Teyber, Reed; Meinhardt, Kerry

    Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass imbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a functionmore » of the bypass flow fraction. Experiments are performed at a fixed temperature span yielding a 30% improvement in net cooling power, affirming the potential of bypass flow in active magnetic regenerative liquefiers.« less

  14. Investigation of bypass fluid flow in an active magnetic regenerative liquefier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holladay, Jamelyn; Teyber, Reed; Meinhardt, Kerry

    Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass imbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a functionmore » of the bypass flow fraction. In conclusion, experiments are performed at a fixed temperature span yielding a 30% improvement in net cooling power, affirming the potential of bypass flow in active magnetic regenerative liquefiers.« less

  15. Environmental Assessment: Johnson County Road F-20 Bypass, Johnson County, Iowa.

    DTIC Science & Technology

    1986-08-01

    D-A184 328 ENVIRONMENTAL ASSESSMENT- JOHNSON COUNTY ROAD F-20 vil BYPASS JOHNSON COUNTY’ IOWA (U) ARMY ENGINEER DISTRICT ROCK ISLAND IL AUG 86...BYPASS JOHNSON COUNTY, IOWA DTIC SELECTEI AUG 24 198D AUGUST 1986 -’"Thn; c>, .. i ’, been p ore i Icr publj rJlxaje aid sale; ii ,,. I distibu on is...2004 19 EPLY TO ATTENTION OP NCRPD-E ENVIRONMENTAL ASSE SSMENT JOHNSON COUNTY ROAD F-20 BYPASS JOHNSON COUNTY, IOWA Acce3siofl For NTIS MR& QUA~rTY

  16. Metal vapor vacuum arc switching - Applications and results. [for launchers

    NASA Technical Reports Server (NTRS)

    Cope, D.; Mongeau, P.

    1984-01-01

    The design of metal-vapor vacuum-arc switches (MVSs) for electromagnetic launchers is discussed, and preliminary results are presented for an experimental MVS. The general principles of triggered-vacuum-gap and vacuum-interrupter MVSs are reviewed, and the requirements of electromagnetic launchers are analyzed. High-current design problems such as electrode erosion, current sharing, magnetic effects, and thermal effects are examined. The experimental MVS employs stainless-steel flanges, a glass vacuum vessel, an adjustable electrode gap, autonomous internal magnetic-field coils, and a tungsten-pin trigger assembly. Some results from tests without magnetic augmentation are presented graphically.

  17. Endovascular Treatments in Combination with Extracranial-Intracranial Bypass for Complex Intracranial Aneurysms.

    PubMed

    Sato, Kenichi; Endo, Hidenori; Fujimura, Miki; Endo, Toshiki; Matsumoto, Yasushi; Shimizu, Hiroaki; Tominaga, Teiji

    2018-05-01

    Although most intracranial aneurysms can be treated with microsurgery or endovascular procedure alone, a subset of aneurysms may require a combined approach. The purpose of this study was to assess the efficacy of endovascular interventions combined with bypass surgery for the treatment of complex intracranial aneurysms. We retrospectively reviewed medical records from a prospectively maintained patient database to identify patients who underwent endovascular treatment of an intracranial aneurysm at our institutes between 2007 and 2017. We recruited patients who received a preplanned combination of endovascular treatment and extracranial-intracranial bypass surgery. Forty-four patients (44 aneurysms) were treated with a combined approach. Twenty-four patients presented with subarachnoid hemorrhage. Treatment strategies included endovascular parent artery occlusion with the bypass surgery to restore cerebral blood flow (n = 12), endovascular trapping with bypass surgery to isolate incorporated branches (n = 12), and intra-aneurysmal coil embolization with bypass surgery to isolate incorporated branches (n = 20). During a mean period of 35.6 months, follow-up catheter angiography was performed in 35 of 44 patients (79.5%) and demonstrated complete aneurysm obliteration in 29 patients (82.9%) and bypass patency in 33 (94.3%). The postoperative aneurysm-related mortality and morbidity rates were 6.8% and 13.6%, respectively. Combined endovascular and surgical bypass procedures are useful for the treatment of complex intracranial aneurysms when conventional surgical or endovascular techniques are not feasible and show acceptable rates of morbidity and mortality. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Totally Endoscopic Coronary Artery Bypass for Anomalous Origin of Right Coronary Artery.

    PubMed

    Kuo, Chia-Cheng; Hsing, Chung-Hsi; Cheng, Bor-Chih

    2017-01-01

    Anomalous origin of the right coronary artery (ARCA) from the left Valsalva sinus is a rare but known cause of sudden cardiac death. Surgical revascularization techniques include coronary artery bypass grafting, unroofing, and reimplantation. We report 4 patients who underwent robot-assisted totally endoscopic coronary artery bypass (TECAB) for ARCA as an alternative surgical option. In 3 patients, a single aortocoronary saphenous vein bypass was performed, and in 1 patient the right internal mammary artery was used. All grafts are patent as shown by computed tomographic angiography or cardiac catheterization. We claim that totally endoscopic coronary artery bypass is feasible and safe for anomalous origin of the right coronary artery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Experimental study of flash boiling spray vaporization through quantitative vapor concentration and liquid temperature measurements

    NASA Astrophysics Data System (ADS)

    Zhang, Gaoming; Hung, David L. S.; Xu, Min

    2014-08-01

    Flash boiling sprays of liquid injection under superheated conditions provide the novel solutions of fast vaporization and better air-fuel mixture formation for internal combustion engines. However, the physical mechanisms of flash boiling spray vaporization are more complicated than the droplet surface vaporization due to the unique bubble generation and boiling process inside a superheated bulk liquid, which are not well understood. In this study, the vaporization of flash boiling sprays was investigated experimentally through the quantitative measurements of vapor concentration and liquid temperature. Specifically, the laser-induced exciplex fluorescence technique was applied to distinguish the liquid and vapor distributions. Quantitative vapor concentration was obtained by correlating the intensity of vapor-phase fluorescence with vapor concentration through systematic corrections and calibrations. The intensities of two wavelengths were captured simultaneously from the liquid-phase fluorescence spectra, and their intensity ratios were correlated with liquid temperature. The results show that both liquid and vapor phase of multi-hole sprays collapse toward the centerline of the spray with different mass distributions under the flash boiling conditions. Large amount of vapor aggregates along the centerline of the spray to form a "gas jet" structure, whereas the liquid distributes more uniformly with large vortexes formed in the vicinity of the spray tip. The vaporization process under the flash boiling condition is greatly enhanced due to the intense bubble generation and burst. The liquid temperature measurements show strong temperature variations inside the flash boiling sprays with hot zones present in the "gas jet" structure and vortex region. In addition, high vapor concentration and closed vortex motion seem to have inhibited the heat and mass transfer in these regions. In summary, the vapor concentration and liquid temperature provide detailed information

  20. Apico-brachiocephalic artery bypass for aortic stenosis with porcelain aorta.

    PubMed

    Shimizu, Shuji; Nakai, Mikizo; Itoh, Atsushi; Yoshizumi, Ko; Ochi, Yoshiki; Okada, Masahiro; Sano, Shunji

    2010-02-01

    Apicoaortic bypass for left ventricular outflow tract obstruction has been performed with acceptable mid-term mortality. However, sometimes it is difficult to anastomose the distal end of the conduit to the calcified descending aorta in patients with a porcelain aorta. We report an aortic non-touch modification of the apicoaortic bypass in an 80-year-old woman with valvular aortic stenosis and a porcelain aorta extending from the ascending to abdominal aorta. We performed apico-brachiocephalic artery bypass under circulatory arrest with deep hypothermia. This procedure may become a useful surgical option for patients with a severe porcelain aorta. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. A Bayesian assessment of the effect of highway bypasses in Iowa on crashes and crash rate.

    PubMed

    Cena, Lorenzo G; Keren, Nir; Li, Wen; Carriquiry, Alicia L; Pawlovich, Michael D; Freeman, Steven A

    2011-08-01

    A common contention is that the construction of highway bypasses negatively impacts the economy of local communities by reducing pass-by traffic for businesses. However, as access to specific business' account records is limited, this impact is difficult to quantify. Another common contention is that bypasses contribute to a reduction in overall crashes in the community and in the surrounding areas. Even though a large number of bypasses have been constructed in the State of Iowa over the past several years, their actual impact in terms of traffic safety has not been quantified. This study seeks answers to the following questions: (a) Are bypasses in Iowa associated with a reduction in crash frequencies and crash rates on the bypassed highway? (b) Do bypasses in Iowa introduce a reduction of overall crash frequencies and rates or do they merely shift crashes from the highways through the communities to the bypasses with no significant overall reduction? We obtained crash information from the Iowa DOT at 19 sites on which a bypass was constructed sometime during the past 23 years. We also obtained the same information at six sites used as comparison sites on which no bypasses were constructed at least until 2005. We them employed a Bayesian approach to estimating the association between the construction of the bypass and crash rates, while also accounting for other factors. The construction of bypasses in Iowa is associated with a significant increase in traffic safety both on the main road through town and on the combined main road and bypass roadway. Copyright © 2011 National Safety Council and Elsevier Ltd. All rights reserved.

  2. Bile acid malabsorption after intestinal bypass surgery for obesity. A comparison between jejunoileal shunt and biliointestinal bypass.

    PubMed

    Nyhlin, H; Brydon, G; Danielsson, A; Eriksson, F

    1990-01-01

    Seventeen patients were operated on with intestinal shunts for morbid obesity, in eight a biliointestinal bypass (BI) was constructed and in the rest a conventional jejunoileal (JI)-shunt. The reduction in weight was similar in both groups, and so was malabsorption of fat, but the BI-group had significantly less bowel motions with less watery diarrhoea. Bile acid malabsorption was measured both chemically by estimating the total amount of faecal bile acids excreted, as well as indirectly by using a 75Se-labelled synthetic bile acid (SeHCAT). Both techniques revealed a substantial loss of bile acid after both types of operation, but patients with BI bypass surgery had significantly lower elimination time of the bile acid than those with JI-shunts. There was a significant negative correlation between SeHCAT retention and total faecal bile acids. However, some patients with low SeHCAT retention had normal or even reduced output of faecal bile acids. Estimation of faecal bile acids may display false negative results when the bile acid pool is decreased. The SeHCAT-test seems to be a better technique for measuring bile acid losses. The study suggests that BI bypass surgery for obesity seems to be advantageous over the JI shunt in reducing the postoperative loss of bile acids and choleretic diarrhoea, without influencing the weight loss.

  3. Controlled assembly of organic whispering-gallery-mode microlasers as highly sensitive chemical vapor sensors.

    PubMed

    Gao, Miaomiao; Wei, Cong; Lin, Xianqing; Liu, Yuan; Hu, Fengqin; Zhao, Yong Sheng

    2017-03-09

    We demonstrate the fabrication of organic high Q active whispering-gallery-mode (WGM) resonators from π-conjugated polymer by a controlled emulsion-solvent-evaporation method, which can simultaneously provide optical gain and act as an effective resonant cavity. By measuring the shift of their lasing modes on exposure to organic vapor, we successfully monitored the slight concentration variation in the chemical gas. These microlaser sensors demonstrated high detection sensitivity and good signal repeatability under continuous chemical gas treatments. The results offer an effective strategy to design miniaturized optical sensors.

  4. Stratospheric water vapor feedback.

    PubMed

    Dessler, A E; Schoeberl, M R; Wang, T; Davis, S M; Rosenlof, K H

    2013-11-05

    We show here that stratospheric water vapor variations play an important role in the evolution of our climate. This comes from analysis of observations showing that stratospheric water vapor increases with tropospheric temperature, implying the existence of a stratospheric water vapor feedback. We estimate the strength of this feedback in a chemistry-climate model to be +0.3 W/(m(2)⋅K), which would be a significant contributor to the overall climate sensitivity. One-third of this feedback comes from increases in water vapor entering the stratosphere through the tropical tropopause layer, with the rest coming from increases in water vapor entering through the extratropical tropopause.

  5. Stratospheric water vapor feedback

    PubMed Central

    Dessler, A. E.; Schoeberl, M. R.; Wang, T.; Davis, S. M.; Rosenlof, K. H.

    2013-01-01

    We show here that stratospheric water vapor variations play an important role in the evolution of our climate. This comes from analysis of observations showing that stratospheric water vapor increases with tropospheric temperature, implying the existence of a stratospheric water vapor feedback. We estimate the strength of this feedback in a chemistry–climate model to be +0.3 W/(m2⋅K), which would be a significant contributor to the overall climate sensitivity. One-third of this feedback comes from increases in water vapor entering the stratosphere through the tropical tropopause layer, with the rest coming from increases in water vapor entering through the extratropical tropopause. PMID:24082126

  6. Biliary bypass surgery – Analysis of indications & outcome of different procedures

    PubMed Central

    Hussain Talpur, K.Altaf; Mahmood Malik, Arshad; Iqbal Memon, Amir; Naeem Qureshi, Jawed; Khan Sangrasi, Ahmed; Laghari, Abdul Aziz

    2013-01-01

    Objectives: This study reports the indications and outcome of various biliary bypass surgical procedures from a single centre over a period of 10 years. Methods: This is a prospective observational study conducted over a period of 10 years (January 2001-december 2010). A total of 1500 patients were included, who underwent pancreatico-biliary surgery due to common bile duct (CBD) stones, congenital anomalies of biliary tree, unoperable pancreatico-biliary malignancies, CBD strictures and cases who developed iatrogenic biliary injuries during cholecystectomy (both open & laproscopic) during this period of time. The patients who required biliary bypass surgery were further analysed for indications and outcome. Results: Out of 1500 patients 83(5.53%) required biliary bypass surgical procedures. The CBD stones were observed as the most common indication (25.3%), followed by CBD injuries after open(10.84%) or laproscopic-cholecystectomy (14.46%), carcinoma head of pancreas (12.05%) and CBD obstruction(14.46%) either due to CBD strictures or unknown distal obstruction. Roux-en-Y-hepatico-jejunostomy (26.51%) was the most frequently performed procedure, followed by choledochoduodenostomy and Roux-en-Y choledocho-jejunostomy (i.e. 25.3% and 12.05% respectively). Roux-en-Y biliary bypass procedure was observed to be associated with better outcome in terms of rate of complications as well duration of hospital stay. Conclusion: Biliary bypass surgical procedures are the better options to restore the continuity of biliary system in patients with iatrogenic biliary tree injuries and un-operable pancreatico-biliary malignancy. Roux-en-Y biliary bypass procedure is safe and problem solving method in these cases. PMID:24353631

  7. Self-Assembly of Nanostructured Electronic Devices (454th Brookhaven Lecture)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, Charles

    2009-12-16

    Given suitable atmospheric conditions, water vapor from the air will crystallize into beautiful structures: snowflakes. Nature provides many other examples of spontaneous organization of materials into regular patterns, which is a process known as self-assembly. Since self-assembly works at all levels, it can be a useful tool for organizing materials on the nanometer scale. In particular, self-assembly provides a precise method for designing materials with improved electronic properties, thereby enabling advances in semiconductor electronics and solar devices. On Wednesday, December 16, at 4 p.m. in Berkner Hall, Charles Black of the Center for Functional Nanomaterials (CFN) will explore this topicmore » during the 454th Brookhaven Lecture, entitled “Self-Assembly of Nanostructured Electronic Devices.” Refreshments will be offered before and after the lecture. To attend this open-to-the-public event, visitors to the Lab ages 16 and older must present photo ID at the Main Gate. During this talk, Dr. Black will discuss examples of how self-assembly is being integrated into semiconductor microelectronics, as advances in the ability to define circuit elements at higher resolution have fueled more than 40 years of performance improvements. Self-assembly also promises advances in the performance of solar devices; thus he will describe his group’s recent results with nanostructured photovoltaic devices.« less

  8. Bypassing birthing centres for child birth: a community-based study in rural Chitwan Nepal.

    PubMed

    Shah, Rajani

    2016-10-21

    Child delivery in a health facility is important to reduce maternal mortality. Bypassing nearby birthing facility to deliver at a hospital is common in developing countries including Nepal. Very little is known about the extent and determinants of bypassing the birthing centres in Nepal. This study measures the status of bypassing, characteristics of bypassers and their reasons for bypassing. A community-based cross-sectional study was carried out in six rural village development committees of Chitwan district of Nepal. Structured interviews were conducted with 263 mothers who had given birth at a health facility and whose nearest facility was a birthing centre. Descriptive statistics, univariate and multivariable logistic regression analysis were performed. More than half of the mothers had bypassed the nearer birthing centres to deliver at hospital. Living in plain area [aOR: 2.467; 95 % CI: 1.005-6.058], higher wealth index [aOR: 4.981; 95 % CI: 2.482-9.999], advantaged caste/ethnicity [aOR: 2.172; 95 % CI: 1.153-4.089], older age [aOR: 2.222; 95 % CI: 1.050-4.703] and first birth [aOR: 2.032; 95 % CI: 1.060-3.894] were associated with higher likelihood of bypassing. Among the reasons of bypassing as reported by the bypassers, lack of operation, video x-ray, and blood test facilities were the most common ones, followed by the lack of medicines/drugs and equipment, lack of skilled service provider, and inadequate physical facilities, among others. Quality of service at the birthing centres needs to be given a high consideration to increase their use as well as to ensure an equitable access to the quality care by all.

  9. The effects of gastric bypass surgery on drug absorption and pharmacokinetics.

    PubMed

    Brocks, Dion R; Ben-Eltriki, Mohamed; Gabr, Raniah Q; Padwal, Raj S

    2012-12-01

    Being overweight is widespread in most societies and represents a major health threat. Gastric bypass surgery offers a highly effective mode of treatment for the morbidly obese patients. The procedures cause an alteration in normal gastrointestinal anatomy and physiology, with consequences not only on nutrient absorption, but also possibly on orally administered drugs. Bypass of the acidic environment of the stomach, partial impairment of bile salts-drug interactions and reduced absorptive surface, all create the potential for reduced absorption of drugs. This article provides an overview of the effects of obesity and the most prevalent type of gastric bypass (Roux-en-Y) on pharmacokinetics. Articles for review were searched using Pubmed. The absorption of those drugs with known bioavailability issues generally seem to be most affected by bypass surgery. It is important to consider the effect of obesity on pharmacokinetics independent of the bypass procedure, because it leads to a dramatic drop in body mass over a relatively short period of time. This may be associated with reversals in the influence of obesity on drug disposition to characteristics more in line with leaner patients. Drugs will differ in their pharmacokinetic response to surgery, limiting any general conclusions regarding the impact of the surgery on drug disposition.

  10. Method and apparatus for vapor detection

    NASA Technical Reports Server (NTRS)

    Lerner, Melvin (Inventor); Hood, Lyal V. (Inventor); Rommel, Marjorie A. (Inventor); Pettitt, Bruce C. (Inventor); Erikson, Charles M. (Inventor)

    1980-01-01

    The method disclosed herein may be practiced by passing the vapors to be sampled along a path with halogen vapor, preferably chlorine vapor, heating the mixed vapors to halogenate those of the sampled vapors subject to halogenation, removing unreacted halogen vapor, and then sensing the vapors for organic halogenated compounds. The apparatus disclosed herein comprises means for flowing the vapors, both sample and halogen vapors, into a common path, means for heating the mixed vapors to effect the halogenation reaction, means for removing unreacted halogen vapor, and a sensing device for sensing halogenated compounds. By such a method and means, the vapors of low molecular weight hydrocarbons, ketones and alcohols, when present, such as methane, ethane, acetone, ethanol, and the like are converted, at least in part, to halogenated compounds, then the excess halogen removed or trapped, and the resultant vapors of the halogenated compounds sensed or detected. The system is highly sensitive. For example, acetone in a concentration of 30 parts per billion (volume) is readily detected.

  11. Predictors of contemporary coronary artery bypass grafting outcomes.

    PubMed

    Weisel, Richard D; Nussmeier, Nancy; Newman, Mark F; Pearl, Ronald G; Wechsler, Andrew S; Ambrosio, Giuseppe; Pitt, Bertram; Clare, Robert M; Pieper, Karen S; Mongero, Linda; Reece, Tammy L; Yau, Terrence M; Fremes, Stephen; Menasché, Philippe; Lira, Armando; Harrington, Robert A; Ferguson, T Bruce

    2014-12-01

    The study objective was to identify the predictors of outcomes in a contemporary cohort of patients from the Reduction in cardiovascular Events by acaDesine in patients undergoing CABG (RED-CABG) trial. Despite the increasing risk profile of patients who undergo coronary artery bypass grafting, morbidity and mortality have remained low, and identification of the current predictors of adverse outcomes may permit new treatments to further improve outcomes. The RED-CABG trial was a multicenter, randomized, double-blind, placebo-controlled study that determined that acadesine did not reduce adverse events in moderately high-risk patients undergoing nonemergency coronary artery bypass grafting. The primary efficacy end point was a composite of all-cause death, nonfatal stroke, or the need for mechanical support for severe left ventricular dysfunction through postoperative day 28. Logistic regression modeling with stepwise variable selection identified which prespecified baseline characteristics were associated with the primary outcome. A second logistic model included intraoperative variables as potential covariates. The 4 independent preoperative risk factors predictive of the composite end point were (1) a history of heart failure (odds ratio, 2.9); (2) increasing age (odds ratio, 1.033 per decade); (3) a history of peripheral vascular disease (odds ratio, 1.6); and (4) receiving aspirin before coronary artery bypass grafting (odds ratio, 0.5), which was protective. The duration of the cardiopulmonary bypass (odds ratio, 1.8) was the only intraoperative variable that contributed to adverse outcomes. Patients who had heart failure and preserved systolic function had a similar high risk of adverse outcomes as those with low ejection fractions, and new approaches may mitigate this risk. Recognition of patients with excessive atherosclerotic burden may permit perioperative interventions to improve their outcomes. The contemporary risks of coronary artery bypass grafting

  12. Postoperative Dysphagia in Debranching Thoracic Endovascular Aortic Repair with Retroesophageal Carotid-Carotid Bypass.

    PubMed

    Yoneyama, Fumiya; Sato, Fujio; Tokunaga, Chiho; Sakamoto, Hiroaki; Enomoto, Yoshiharu; Watanabe, Yutaka; Hiramatsu, Yuji

    2017-08-01

    A carotid-carotid bypass is commonly used in debranching thoracic endovascular aortic repair. When the bypass graft is placed in the retroesophageal position, the esophagus may be compressed by the graft from behind. Therefore, dysphagia may occur postoperatively as a serious complication. To avoid this issue, we recommend placing the bypass graft below the cricoid cartilage. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Nonlinear Dynamic Analysis of Disordered Bladed-Disk Assemblies

    NASA Technical Reports Server (NTRS)

    McGee, Oliver G., III

    1997-01-01

    In a effort to address current needs for efficient, air propulsion systems, we have developed some new analytical predictive tools for understanding and alleviating aircraft engine instabilities which have led to accelerated high cycle fatigue and catastrophic failures of these machines during flight. A frequent cause of failure in Jets engines is excessive resonant vibrations and stall flutter instabilities. The likelihood of these phenomena is reduced when designers employ the analytical models we have developed. These prediction models will ultimately increase the nation's competitiveness in producing high performance Jets engines with enhanced operability, energy economy, and safety. The objectives of our current threads of research in the final year are directed along two lines. First, we want to improve the current state of blade stress and aeromechanical reduced-ordered modeling of high bypass engine fans, Specifically, a new reduced-order iterative redesign tool for passively controlling the mechanical authority of shroudless, wide chord, laminated composite transonic bypass engine fans has been developed. Second, we aim to advance current understanding of aeromechanical feedback control of dynamic flow instabilities in axial flow compressors. A systematic theoretical evaluation of several approaches to aeromechanical feedback control of rotating stall in axial compressors has been conducted. Attached are abstracts of two .papers under preparation for the 1998 ASME Turbo Expo in Stockholm, Sweden sponsored under Grant No. NAG3-1571. Our goals during the final year under Grant No. NAG3-1571 is to enhance NASA's capabilities of forced response of turbomachines (such as NASA FREPS). We with continue our development of the reduced-ordered, three-dimensional component synthesis models for aeromechanical evaluation of integrated bladeddisk assemblies (i.e., the disk, non-identical bladeing etc.). We will complete our development of component systems design

  14. Cigarette smoking in British men and selection for coronary artery bypass surgery.

    PubMed Central

    Morris, R. W.; McCallum, A. K.; Walker, M.; Whincup, P. H.; Ebrahim, S.; Shaper, A. G.

    1996-01-01

    OBJECTIVE: To examine the relation between smoking status, clinical need, and likelihood of coronary artery bypass grafting in middle aged men. DESIGN: A prospective study of cardiovascular disease in British men aged 40 to 59 years, screened in 1978-80 and followed until December 1991. SUBJECTS AND SETTING: 7735 men drawn from one general practice in each of 24 British towns. MAIN OUTCOME MEASURE: Coronary artery bypass graft surgery. RESULTS: Of the 3185 current smokers, 38 (1.03/1000/year) underwent coronary artery bypass surgery compared with 47 of 2715 (1.45/1000/year) ex-smokers, and 19 of 1817 (0.85/1000/year) never-smokers. Ex-smokers had a lower incidence of major ischaemic heart disease during follow up than current smokers. After adjustment for incidence of ischaemic heart disease during follow up, the hazard ratio of coronary artery bypass surgery for ex-smokers compared with smokers was 1.52 (95% confidence interval 0.99 to 2.34). Ex-smokers were more likely at screening to recall a doctor diagnosis of ischaemic heart disease than smokers (7.1% v 5.3%), but among those who recalled a doctor diagnosis, smokers were less likely to undergo coronary artery bypass surgery than ex-smokers (9.4% v 3.5%, P = 0.026). By 1992, men defined as smokers at screening were no less likely than ex-smokers to have been referred to a cardiologist (18.5% v 18.8%), nor to report having undergone coronary angiography less frequently than ex-smokers (12.7% v 11.4%). CONCLUSION: Even allowing for the strong relation between coronary artery bypass surgery and clinical need, continuing smokers were less likely to undergo coronary artery bypass surgery than ex-smokers. A complex interplay exists between the men's experience of heart disease, the decision to stop smoking, and the willingness of doctors to consider coronary artery bypass surgery. PMID:8697156

  15. Experiences of marijuana-vaporizer users.

    PubMed

    Malouff, John M; Rooke, Sally E; Copeland, Jan

    2014-01-01

    Using a marijuana vaporizer may have potential harm-reduction advantages on smoking marijuana, in that the user does not inhale smoke. Little research has been published on use of vaporizers. In the first study of individuals using a vaporizer on their own initiative, 96 adults anonymously answered questions about their experiences with a vaporizer and their use of marijuana with tobacco. Users identified 4 advantages to using a vaporizer over smoking marijuana: perceived health benefits, better taste, no smoke smell, and more effect from the same amount of marijuana. Users identified 2 disadvantages: inconvenience of setup and cleaning and the time it takes to get the device operating for each use. Only 2 individuals combined tobacco in the vaporizer mix, whereas 15 combined tobacco with marijuana when they smoked marijuana. Almost all participants intended to continue using a vaporizer. Vaporizers seem to have appeal to marijuana users, who perceive them as having harm-reduction and other benefits. Vaporizers are worthy of experimental research evaluating health-related effects of using them.

  16. Early superficial temporal artery to middle cerebral artery bypass in acute ischemic stroke.

    PubMed

    Lee, Sang-Bok; Huh, Pil-Woo; Kim, Dal-Soo; Yoo, Do-Sung; Lee, Tae-Gyu; Cho, Kyoung-Suok

    2013-08-01

    To evaluate the effects and safety of superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis in the early stage after an acute ischemic event and the improvement of present symptoms in patients with intracranial atherosclerotic occlusive disease with stroke/stroke in progress. From 2006 to 2010, 20 patients (15 males and five females) with atherosclerotic cerebrovascular disease were treated with an STA-MCA bypass. All of the patients presented with an acute ischemic stroke or stroke in progress despite maximal medical treatment. The patients underwent an STA-MCA bypass within 7 days from symptom onset. The clinical outcome and hemodynamic study of the 20 patients were preoperatively and postoperatively investigated. A pooled analysis was performed, and the results were compared with those obtained from other delayed STA-MCA bypass studies. Among the 20 patients who underwent an early STA-MCA bypass, fourteen (70%) patients achieved a good functional outcome (mRS 0, n=3; mRS 1, n=9; mRS 2, n=2). Prior to surgery, the mean basal regional cerebral blood flow (rCBF) and cerebrovascular reserve capacity (CVR) in the symptomatic hemisphere were 37.3±4.3 ml/100 g/min and -1.68±2.9%. The mean basal rCBF and CVR had significantly increased postoperatively, and no reperfusion-induced hemorrhage had occurred. In the pooled analysis, no significant differences were observed in the clinical outcome (P=0.328) or in the incidence of postoperative complications (P=0.516) between patients who underwent an early STA-MCA bypass and in patients who underwent a delayed STA-MCA bypass in previous studies. In this study, which consisted of 20 carefully selected patients with acute ischemic stroke, an early STA-MCA bypass was safely and effectively performed, and in some cases, an early STA-MCA bypass resulted in rapid neurological improvement. An early STA-MCA bypass was beneficial in select patients who had acute ischemic stroke with imaging evidence of a small

  17. Environmental impact case study : Martinsville bypass.

    DOT National Transportation Integrated Search

    1971-01-01

    At the request of the Environmental Quality Division, the Environmental and Economics Section of the Virginia Highway Research Council conducted an environmental impact study of the proposed Route 220 bypass around Martinsville. This evaluation of th...

  18. Modeling Effects of RNA on Capsid Assembly Pathways via Coarse-Grained Stochastic Simulation

    PubMed Central

    Smith, Gregory R.; Xie, Lu; Schwartz, Russell

    2016-01-01

    The environment of a living cell is vastly different from that of an in vitro reaction system, an issue that presents great challenges to the use of in vitro models, or computer simulations based on them, for understanding biochemistry in vivo. Virus capsids make an excellent model system for such questions because they typically have few distinct components, making them amenable to in vitro and modeling studies, yet their assembly can involve complex networks of possible reactions that cannot be resolved in detail by any current experimental technology. We previously fit kinetic simulation parameters to bulk in vitro assembly data to yield a close match between simulated and real data, and then used the simulations to study features of assembly that cannot be monitored experimentally. The present work seeks to project how assembly in these simulations fit to in vitro data would be altered by computationally adding features of the cellular environment to the system, specifically the presence of nucleic acid about which many capsids assemble. The major challenge of such work is computational: simulating fine-scale assembly pathways on the scale and in the parameter domains of real viruses is far too computationally costly to allow for explicit models of nucleic acid interaction. We bypass that limitation by applying analytical models of nucleic acid effects to adjust kinetic rate parameters learned from in vitro data to see how these adjustments, singly or in combination, might affect fine-scale assembly progress. The resulting simulations exhibit surprising behavioral complexity, with distinct effects often acting synergistically to drive efficient assembly and alter pathways relative to the in vitro model. The work demonstrates how computer simulations can help us understand how assembly might differ between the in vitro and in vivo environments and what features of the cellular environment account for these differences. PMID:27244559

  19. Self-assembly of dodecaphenyl POSS thin films

    NASA Astrophysics Data System (ADS)

    Handke, Bartosz; Klita, Łukasz; Niemiec, Wiktor

    2017-12-01

    The self-assembly abilities of Dodecaphenyl Polyhedral Oligomeric Silsesquioxane thin films on Si(1 0 0) surfaces were studied. Due to their thermal properties - relatively low sublimation temperature and preservation of molecular structure - cage type silsesquioxanes are ideal material for the preparation of a thin films by Physical Vapor Deposition. The Ultra-High Vacuum environment and the deposition precision of the PVD method enable the study of early stages of thin film growth and its molecular organization. X-ray Reflectivity and Atomic Force Microscopy measurements allow to pursuit size-effects in the structure of thin films with thickness ranges from less than a single molecular layer up to several tens of layers. Thermal treatment of the thin films triggered phase change: from a poorly ordered polycrystalline film into a well-ordered multilayer structure. Self-assembly of the layers is the effect of the π-stacking of phenyl rings, which force molecules to arrange in a superlattice, forming stacks of alternating organic-inorganic layers.

  20. The Benefits of Photorespiratory Bypasses: How Can They Work?1[OPEN

    PubMed Central

    Xin, Chang-Peng; Tholen, Danny; Devloo, Vincent; Zhu, Xin-Guang

    2015-01-01

    Bypassing the photorespiratory pathway is regarded as a way to increase carbon assimilation and, correspondingly, biomass production in C3 crops. Here, the benefits of three published photorespiratory bypass strategies are systemically explored using a systems-modeling approach. Our analysis shows that full decarboxylation of glycolate during photorespiration would decrease photosynthesis, because a large amount of the released CO2 escapes back to the atmosphere. Furthermore, we show that photosynthesis can be enhanced by lowering the energy demands of photorespiration and by relocating photorespiratory CO2 release into the chloroplasts. The conductance of the chloroplast membranes to CO2 is a key feature determining the benefit of the relocation of photorespiratory CO2 release. Although our results indicate that the benefit of photorespiratory bypasses can be improved by increasing sedoheptulose bisphosphatase activity and/or increasing the flux through the bypass, the effectiveness of such approaches depends on the complex regulation between photorespiration and other metabolic pathways. PMID:25516604

  1. Intraoperative Evaluation of Reverse Bypass Using a Naturally Formed "Bonnet" Superficial Temporal Artery: Technical Note.

    PubMed

    Nagm, Alhusain; Horiuchi, Tetsuyoshi; Hasegawa, Takatoshi; Hongo, Kazuhiro

    2016-04-01

    In reverse bypass that used a naturally formed "bonnet" superficial temporal artery, intraoperative volume flow measurement quantifies flow augmentation after revascularization, confirms flow preservation, and identifies inadvertent vessel compromise. A 75-year-old man presented with transient ischemic attacks attributed to right internal carotid artery stenosis. He underwent successful reverse bypass via a naturally formed "bonnet" superficial temporal artery middle cerebral artery bypass. As the result of proper intraoperative volume flow evaluation, a successful reverse bypass was achieved. Modification of the intraoperative stroke risk and prediction of the long-term patency after reverse bypass can be achieved by meticulous intraoperative blood flow evaluation. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Gasoline Vapor Recovery

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Gasoline is volatile and some of it evaporates during storage, giving off hydrocarbon vapor. Formerly, the vapor was vented into the atmosphere but anti-pollution regulations have precluded that practice in many localities, so oil companies and storage terminals are installing systems to recover hydrocarbon vapor. Recovery provides an energy conservation bonus in that most of the vapor can be reconverted to gasoline. Two such recovery systems are shown in the accompanying photographs (mid-photo at right and in the foreground below). They are actually two models of the same system, although.configured differently because they are customized to users' needs. They were developed and are being manufactured by Edwards Engineering Corporation, Pompton Plains, New Jersey. NASA technological information proved useful in development of the equipment.

  3. Rankine cycle load limiting through use of a recuperator bypass

    DOEpatents

    Ernst, Timothy C.

    2011-08-16

    A system for converting heat from an engine into work includes a boiler coupled to a heat source for transferring heat to a working fluid, a turbine that transforms the heat into work, a condenser that transforms the working fluid into liquid, a recuperator with one flow path that routes working fluid from the turbine to the condenser, and another flow path that routes liquid working fluid from the condenser to the boiler, the recuperator being configured to transfer heat to the liquid working fluid, and a bypass valve in parallel with the second flow path. The bypass valve is movable between a closed position, permitting flow through the second flow path and an opened position, under high engine load conditions, bypassing the second flow path.

  4. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  5. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  6. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  7. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  8. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  9. Self-assembled growth and structural analysis of inclined GaN nanorods on nanoimprinted m-sapphire using catalyst-free metal-organic chemical vapor deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Kyuseung; Chae, Sooryong; Jang, Jongjin

    2016-04-15

    In this study, self-assembled inclined (1-10-3)-oriented GaN nanorods (NRs) were grown on nanoimprinted (10-10) m-sapphire substrates using catalyst-free metal-organic chemical vapor deposition. According to X-ray phi-scans, the inclined GaN NRs were tilted at an angle of ∼57.5° to the [10-10]{sub sapp} direction. Specifically, the GaN NRs grew in a single inclined direction to the [11-20]{sub sapp}. Uni-directionally inclined NRs were formed through the one-sided (10-11)-faceted growth of the interfacial a-GaN plane layer. It was confirmed that a thin layer of a-GaN was formed on r-facet nanogrooves of the m-sapphire substrate by nitridation. The interfacial a-GaN nucleation affected both the inclinedmore » angle and the growth direction of the inclined GaN NRs. Using X-ray diffraction and selective area electron diffraction, the epitaxial relationship between the inclined (1-10-3) GaN NRs and interfacial a-GaN layer on m-sapphire substrates was systematically investigated. Moreover, the inclined GaN NRs were observed to be mostly free of stacking fault-related defects using high-resolution transmission electron microscopy.« less

  10. Roux-en-Y gastric bypass reversal: a systematic review.

    PubMed

    Shoar, Saeed; Nguyen, Thu; Ona, Mel A; Reddy, Madhavi; Anand, Sury; Alkuwari, Mohammed J; Saber, Alan A

    2016-08-01

    Due to the large number of Roux-en-Y gastric bypass surgeries performed over the last decade, reversal of the bypass to normal anatomy has been increasingly reported. University affiliated Teaching Hospital, United States. The aim of this systematic review was to summarize the literature data regarding the indications, technical considerations, and outcomes of gastric bypass reversal. PubMed/MEDLINE search was conducted for articles reporting reversal of gastric bypass to normal anatomy. Patients' demographic characteristics, primary reason for reversal, reversal technique, and postreversal events were retrieved and categorized from each eligible paper. Thirty-five articles encompassing a total of 100 patients were eligible. Malnutrition was the most common indication for reversal (12.3%), followed by severe dumping syndrome (9.4%), postprandial hypoglycemia (8.5%), and excessive weight loss (8.5%). Techniques for gastrogastrostomy were available in 42 patients, with the hand-sewn technique as the most common (67.4%) followed by the linear stapler (23.2%) and the end-to-end anastomosis stapler used in 3 patients (6.9%). The reversal technique was performed endoscopically and described in 3 studies (3 patients). Techniques for handling the Roux limb were described in 56 patients (56%); the limb was reconnected in 32 patients (57.2%) and resected in 24 patients (42.8%). Weight regain was the most prevalent postreversal event (28.8%), followed by severe gastroesophageal reflux diseases (10.2%) and persistent abdominal pain (6.8%). There was no reported mortality. Gastric bypass reversal is indicated for excessive weight loss, dumping syndrome, and postprandial hypoglycemia. The procedure is well tolerated and feasible when performed laparoscopically and has no reported mortality. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  11. Investigation on the Core Bypass Flow in a Very High Temperature Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassan, Yassin

    2013-10-22

    Uncertainties associated with the core bypass flow are some of the key issues that directly influence the coolant mass flow distribution and magnitude, and thus the operational core temperature profiles, in the very high-temperature reactor (VHTR). Designers will attempt to configure the core geometry so the core cooling flow rate magnitude and distribution conform to the design values. The objective of this project is to study the bypass flow both experimentally and computationally. Researchers will develop experimental data using state-of-the-art particle image velocimetry in a small test facility. The team will attempt to obtain full field temperature distribution using racksmore » of thermocouples. The experimental data are intended to benchmark computational fluid dynamics (CFD) codes by providing detailed information. These experimental data are urgently needed for validation of the CFD codes. The following are the project tasks: • Construct a small-scale bench-top experiment to resemble the bypass flow between the graphite blocks, varying parameters to address their impact on bypass flow. Wall roughness of the graphite block walls, spacing between the blocks, and temperature of the blocks are some of the parameters to be tested. • Perform CFD to evaluate pre- and post-test calculations and turbulence models, including sensitivity studies to achieve high accuracy. • Develop the state-of-the art large eddy simulation (LES) using appropriate subgrid modeling. • Develop models to be used in systems thermal hydraulics codes to account and estimate the bypass flows. These computer programs include, among others, RELAP3D, MELCOR, GAMMA, and GAS-NET. Actual core bypass flow rate may vary considerably from the design value. Although the uncertainty of the bypass flow rate is not known, some sources have stated that the bypass flow rates in the Fort St. Vrain reactor were between 8 and 25 percent of the total reactor mass flow rate. If bypass flow rates are

  12. Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.

    PubMed

    Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro

    2013-01-01

    The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.

  13. Extended use of cardiopulmonary bypass in a multidisciplinary hospital

    PubMed Central

    Shahabuddin, Syed; Habib, Nabeel

    2015-01-01

    Objective To share our experience highlighting the additional use of cardiopulmonary bypass (CPB) in cases other than the conventional ischemic, congenital and valvular heart diseases. Methodology All patients undergoing non-traditional cardiac surgery utilizing the cardiopulmonary bypass during a period from 1999 to 2009 reviewed. Their preoperative presentation, operative strategy and immediate postoperative status were assessed. Results A total of six such cases were identified including three female and three male patients. Two patients presented with road traffic accident having aortic transection along with other injuries. They underwent repair utilizing partial cardiopulmonary bypass. One patient presented with large PDA aneurysm and symptoms related to its pressure effect on respiratory system. He underwent repair under hypothermic circulatory arrest. These three patients were done via left thoracotomy. Three patients underwent deep hypothermic circulatory arrest, one for removal of thrombus from right atrium after complicated liver abscess, one patient required vascular graft interposition in left internal carotid artery for aneurysm extending into cranium and the third one underwent resection of vascular tumor of posterior cranial fossa. One patient required exploration for bleeding. One patient died after prolonged hospitalization. Rest of the patient had unremarkable postoperative course and were discharged home. Conclusion Our short experience highlights the extended use of cardiopulmonary bypass in a multidisciplinary hospital, facilitating to perform complex, technically challenging non cardiac procedures which otherwise may not be possible. PMID:26309443

  14. Factors influencing wound healing of critical ischaemic foot after bypass surgery: is the angiosome important in selecting bypass target artery?

    PubMed

    Azuma, N; Uchida, H; Kokubo, T; Koya, A; Akasaka, N; Sasajima, T

    2012-03-01

    The aim of the study is to determine factors affecting ischaemic wound healing and role of the angiosome concept in bypass surgery. Single-centre, retrospective clinical study. A total of 249 consecutive critical ischaemic limbs with tissue loss in 228 patients who underwent distal bypasses from 2003 to 2009 were reviewed. A total of 81% of patients were diabetic, and 49% of patients had dialysis-dependent renal disease (end-stage renal disease, ESRD). Distal targets of bypasses were the crural artery (57%) and the pedal artery (43%). The complete healing of ischaemic wounds was achieved in 211 limbs (84.7%). ESRD (odds ratio (OR) 0.127, p < 0.001), diabetes (OR 0.216, p = 0.030), Rutherford category 6 (R6) with heel ulcer/gangrene (OR 0.134, p < 0.001), R6 except heel (OR 0.336, p = 0.025) and low albuminaemia (OR 0.387, p = 0.049) were negative predictors of wound healing. Regarding the angiosome, the healing rate in the indirect revascularisation (IR) group was slower than in the direct revascularisation (DR) group, especially in patients with ESRD (p < 0.001). However, the healing rates of the DR and IR groups were similar after minimising background differences with propensity score methods (p = 0.185). In the field of bypass surgery, the angiosome concept seems unimportant, at least in non-ESRD cases. The location and extent of ischaemic wounds as well as co-morbidities may be more relevant than the angiosome in terms of wound healing. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Endothelin and vasopressin influence splanchnic blood flow distribution during and after cardiopulmonary bypass.

    PubMed

    Bomberg, Hagen; Bierbach, Benjamin; Flache, Stephan; Wagner, Isabell; Gläser, Lena; Groesdonk, Heinrich V; Menger, Michael D; Schäfers, Hans-Joachim

    2013-02-01

    Gastrointestinal blood flow can be compromised during and after cardiopulmonary bypass. Endothelin has been shown to be involved in the intestinal microcirculatory disturbance of sepsis. The aim of the present study was to analyze the involvement of the endothelin system on intestinal blood flow regulation during cardiopulmonary bypass and the effect of vasopressin given during cardiopulmonary bypass. A total of 24 pigs were studied in 4 groups (n = 6): group I, sham; group II, ischemia/reperfusion with 1 hour of superior mesenteric artery occlusion; group III, cardiopulmonary bypass for 1 hour; and group IV, 1 hour of cardiopulmonary bypass plus vasopressin administration, maintaining the baseline arterial pressure. All the pigs were reperfused for 90 minutes. During the experiment, the hemodynamics and jejunal microcirculation were measured continuously. The jejunal mucosal expression of endothelin-1 and its receptor subtypes A and B were determined using polymerase chain reaction. During cardiopulmonary bypass, superior mesenteric artery flow was preserved but marked jejunal microvascular impairment occurred compared with baseline (mucosal capillary density, 192.2 ± 5.4 vs 150.8 ± 5.1 cm/cm(2); P = .005; tissue blood flow, 501.7 ± 39.3 vs 332.3 ± 27.9 AU; P = .025). The expression of endothelin-1 after cardiopulmonary bypass (3.2 ± 0.4 vs 12.2 ± 0.8 RQ, P = .006) and endothelin subtype A (0.7 ± 0.2 vs 2.4 ± 0.6 RQ; P = .01) was significantly increased compared to the sham group. Vasopressin administration during cardiopulmonary bypass led to normal capillary density (189.9 ± 3.9 vs 178.0 ± 6.3; P = .1) and tissue blood flow (501.7 ± 39.3 vs 494.7 ± 44.4 AU; P = .4) compared with baseline. The expression of endothelin-1 (3.2 ± 0.4 vs 1.8 ± 0.3 RQ; P = .3) and endothelin subtype A (0.7 ± 0.2 vs 0.9 ± 0.2 RQ; P = .5) was not different from the sham group. Cardiopulmonary bypass leads to microvascular impairment of jejunal microcirculation, which is

  16. Oil Bypass Filter Technology Evaluation, Fourth Quarterly Report, July--September 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James E. Francfort; Larry Zirker

    2003-11-01

    This fourth Oil Bypass Filter Technology Evaluation report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy’s FreedomCAR & Vehicle Technologies Program. Eight four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass filter systems from the puraDYN Corporation. The bypass filters are reported to have engine oil filtering capability of <1 micron and a built-in additive package to facilitate extended oil-drain intervals. To date, the eight buses have accumulated 259,398 test miles. This represents anmore » avoidance of 21 oil changes, which equates to 740 quarts (185 gallons) of oil not used or disposed of. To validate the extended oil-drain intervals, an oil-analysis regime evaluates the fitness of the oil for continued service by monitoring the presence of necessary additives, undesirable contaminants, and engine-wear metals. For bus 73450, higher values of iron have been reported, but the wear rate ratio (parts per million of iron per thousand miles driven) has remained consistent. In anticipation of also evaluating oil bypass systems on six Chevrolet Tahoe sport utility vehicles, the oil is being sampled on each of the Tahoes to develop a characterization history or baseline for each engine.« less

  17. Enhancing cell-free layer thickness by bypass channels in a wall.

    PubMed

    Saadatmand, M; Shimogonya, Y; Yamaguchi, T; Ishikawa, T

    2016-07-26

    When blood flows near a wall, red blood cells (RBCs) drift away from the wall and a cell-free layer (CFL) is formed adjacent to the wall. Controlling the CFL thickness is important for preventing adhesion of cells in the design of biomedical devices. In this study, a novel wall configuration with stenoses and bypass channels is proposed to increase the CFL thickness. We found that the presence of bypass channels modified the spatial distribution of cells and substantially increased the CFL downstream of the stenosis. A single-bypass geometry with 5% hematocrit (Hct) blood flow showed a 1.7μm increase in CFL thickness compared to without the bypass. In the case of three bypass channels, a 3μm increase in CFL thickness was observed. The CFL enhancement was observed up to 10% Hct, but no significant enhancement of CFL was indicated for 20% Hct blood flow. The mechanism of the CFL enhancement was investigated using a numerical simulation of the flow field. The results showed that the distance between each streamline and the corner of the stenosis compared with size of RBC was important parameter in regulating CFL thickness. These results show the potential of the proposed mechanism to prevent adhesion of cells to biomedical devices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Resource utilization related to atrial fibrillation after coronary artery bypass grafting.

    PubMed

    Hravnak, Marilyn; Hoffman, Leslie A; Saul, Melissa I; Zullo, Thomas G; Whitman, Gayle R

    2002-05-01

    Studies of resource utilization by patients with new-onset atrialfibrillation after coronary artery bypass grafting have addressed only length of stay and bed charges. To compare resource utilization between patients with new-onset atrial fibrillation and patients without atrialfibrillation after isolated coronary artery bypass grafting. Retrospective review of clinical and administrative electronic databases for 720 subjects who underwent isolated coronary artery bypass grafting with cardiopulmonary bypass in 25 months at one medical center The prevalence of atrial fibrillation was determined, and resource utilization in various hospital cost centers was compared between subjects with and without atrialfibrillation. The prevalence of new-onset atrial fibrillation was 33.1%. Compared with subjects without atrialfibrillation, subjects with atrialfibrillation had a longer stay (5.8 +/- 2.4 vs. 4.4+/-1.2 days, P<.001), more days receiving mechanical ventilation (P =.002) and oxygen therapy (P<.001), and higher rates of readmission to the intensive care unit (4.6% vs. 0.2%, P<.001). Subjects with atrial fibrillation also had more laboratory tests (P<.001) and more days receiving cardiac drugs, heparin, diuretics, and electrolytes. Subjects with atrialfibrillation had higher total postoperative charges ($57261 +/- $17101 vs. $50905 +/- $10062, P = .001), a mean difference of $6356. The mean differences were greatest for bed charges ($1642), laboratory charges ($1215), pharmacy ($989), and respiratory care ($582). The economic impact of atrialfibrillation after coronary artery bypass grafting has been underestimated.

  19. Analysis of pesticides in surface water and sediment from Yolo Bypass, California, 2004-2005

    USGS Publications Warehouse

    Smalling, Kelly L.; Orlando, James L.; Kuivila, Kathryn

    2005-01-01

    Inputs to the Yolo Bypass are potential sources of pesticides that could impact critical life stages of native fish. To assess the direct inputs during inundation, pesticide concentrations were analyzed in water, in suspended and bed-sediment samples collected from six source watersheds to the Yolo Bypass, and from three sites within the Bypass in 2004 and 2005. Water samples were collected in February 2004 from the six input sites to the Bypass during the first flood event of the year representing pesticide inputs during high-flow events. Samples were also collected along a transect across the Bypass in early March 2004 and from three sites within the Bypass in the spring of 2004 under low-flow conditions. Low-flow data were used to understand potential pesticide contamination and its effects on native fish if water from these areas were used to flood the Bypass in dry years. To assess loads of pesticides to the Bypass associated with suspended sediments, large-volume water samples were collected during high flows in 2004 and 2005 from three sites, whereas bed sediments were collected from six sites in the fall of 2004 during the dry season. Thirteen current-use pesticides were detected in surface water samples collected during the study. The highest pesticide concentrations detected at the input sites to the Bypass corresponded to the first high-flow event of the year. The highest pesticide concentrations at the two sites sampled within the Bypass during the early spring were detected in mid-April following a major flood event as the water began to subside. The pesticides detected and their concentrations in the surface waters varied by site; however, hexazinone and simazine were detected at all sites and at some of the highest concentrations. Thirteen current-use pesticides and three organochlorine insecticides were detected in bed and suspended sediments collected in 2004 and 2005. The pesticides detected and their concentrations varied by site and sediment

  20. Demisable Reaction-Wheel Assembly

    NASA Technical Reports Server (NTRS)

    Roder, Russell; Ahronovich, Eliezer; Davis, Milton C., III

    2008-01-01

    A document discusses the concept of a demisable motor-drive-and-flywheel assembly [reaction-wheel assembly (RWA)] used in controlling the attitude of a spacecraft. Demisable as used here does not have its traditional legal meaning; instead, it signifies susceptible to melting, vaporizing, and/or otherwise disintegrating during re-entry of the spacecraft into the atmosphere of the Earth so as not to pose a hazard to anyone or anything on the ground. Prior RWAs include parts made of metals (e.g., iron, steel, and titanium) that melt at high temperatures and include structures of generally closed character that shield some parts (e.g., magnets) against re-entry heating. In a demisable RWA, the flywheel would be made of aluminum, which melts at a lower temperature. The flywheel web would not be a solid disk but would have a more open, nearly-spoke-like structure so that it would disintegrate more rapidly; hence, the flywheel rim would separate more rapidly so that parts shielded by the rim would be exposed sooner to re-entry heating. In addition, clearances between the flywheel and other components would be made greater, imparting a more open character and thus increasing the exposure of those components.

  1. EC-IC bypass for cavernous carotid aneurysms: An initial experience with twelve patients

    PubMed Central

    Menon, G.; Jayanand, Sudhir; Krishnakumar, K.; Nair, S.

    2014-01-01

    Aims: Need for performing a bypass procedure prior to parent artery occlusion in patients with good cerebral vascular reserve is controversial. We analyze our experience of 12 giant internal carotid artery aneurysms treated with extracranial-intracranial (EC-IC) bypass and proximal artery occlusion. Materials and Methods: Retrospective analysis of the case records of all complex carotid aneurysms operated in our institute since January 2009. Results: The study included eleven cavernous carotid aneurysms and one large fusiform cervical carotid aneurysm reaching the skull base. Preoperative assessment of cerebral vascular reserve was limited to Balloon test occlusion with hypotensive challenge. Eleven patients who successfully completed a Balloon test occlusion (BTO) underwent low flow superficial temporal artery to middle cerebral artery (STA-MCA) bypass, while one patient with a failed BTO underwent a high flow bypass using a saphenous vein graft. Parent artery ligation was performed in all patients following the bypass procedure. Check angiogram revealed thrombosis of the aneurysm in all patients with a graft patency rate of 81.8%. We had one operative mortality, probably related to a leak from the anastomotic site. The only patient who had a high flow bypass developed contralateral hemispheric infarcts and remained vegetative. All the other patients had a good recovery and with a Glasgow outcome score of 5 at last follow-up. Conclusion: We feel that combining EC-IC bypass prior to parent vessel occlusion helps in reducing the risk of post operative ischemic complications especially in situations where a complete mandated cerebral blood flow studies are not feasible. PMID:25126123

  2. Development of a preprototype vapor compression distillation water recovery subsystem

    NASA Technical Reports Server (NTRS)

    Johnson, K. L.

    1978-01-01

    The activities involved in the design, development, and test of a preprototype vapor compression distillation water recovery subsystem are described. This subsystem, part of a larger regenerative life support evaluation system, is designed to recover usable water from urine, urinal rinse water, and concentrated shower and laundry brine collected from three space vehicle crewmen for a period of 180 days without resupply. Details of preliminary design and testing as well as component developments are included. Trade studies, considerations leading to concept selections, problems encountered, and test data are also presented. The rework of existing hardware, subsystem development including computer programs, assembly verification, and comprehensive baseline test results are discussed.

  3. Gastric infarction following gastric bypass surgery

    PubMed Central

    Do, Patrick H; Kang, Young S; Cahill, Peter

    2016-01-01

    Gastric infarction is an extremely rare occurrence owing to the stomach’s extensive vascular supply. We report an unusual case of gastric infarction following gastric bypass surgery. We describe the imaging findings and discuss possible causes of this condition. PMID:27200168

  4. New self-limiting assembly model for Si quantum rings on Si(100).

    PubMed

    Yu, L W; Chen, K J; Song, J; Xu, J; Li, W; Li, X F; Wang, J M; Huang, X F

    2007-04-20

    We propose a new self-limiting assembly model for Si quantum rings on Si(100) where the ring's formation and evolution are driven by a growth-etching competition mechanism. The as-grown ring structure in a plasma enhanced chemical vapor deposition system has excellent rotational symmetry and superior morphology with a typical diameter, edge width, and height of 150-300, 10, and 5 nm, respectively. Based on this model, the size and morphology can be controlled well by simply tuning the timing procedure. We suggest that this growth model is not limited to certain material system, but provides a general scheme to control and tailor the self-assembly nanostructures into the desired size, shape, and complexity.

  5. Means and method for vapor generation

    DOEpatents

    Carlson, Larry W.

    1984-01-01

    A liquid, in heat transfer contact with a surface heated to a temperature well above the vaporization temperature of the liquid, will undergo a multiphase (liquid-vapor) transformation from 0% vapor to 100% vapor. During this transition, the temperature driving force or heat flux and the coefficients of heat transfer across the fluid-solid interface, and the vapor percentage influence the type of heating of the fluid--starting as "feedwater" heating where no vapors are present, progressing to "nucleate" heating where vaporization begins and some vapors are present, and concluding with "film" heating where only vapors are present. Unstable heating between nucleate and film heating can occur, accompanied by possibly large and rapid temperature shifts in the structures. This invention provides for injecting into the region of potential unstable heating and proximate the heated surface superheated vapors in sufficient quantities operable to rapidly increase the vapor percentage of the multiphase mixture by perhaps 10-30% and thereby effectively shift the multiphase mixture beyond the unstable heating region and up to the stable film heating region.

  6. Means and method for vapor generation

    DOEpatents

    Carlson, L.W.

    A liquid, in heat transfer contact with a surface heated to a temperature well above the vaporization temperature of the liquid, will undergo a multiphase (liquid-vapor) transformation from 0% vapor to 100% vapor. During this transition, the temperature driving force or heat flux and the coefficients of heat transfer across the fluid-solid interface, and the vapor percentage influence the type of heating of the fluid - starting as feedwater heating where no vapors are present, progressing to nucleate heating where vaporization begins and some vapors are present, and concluding with film heating where only vapors are present. Unstable heating between nucleate and film heating can occur, accompanied by possibly large and rapid temperature shifts in the structures. This invention provides for injecting into the region of potential unstable heating and proximate the heated surface superheated vapors in sufficient quantities operable to rapidly increase the vapor percentage of the multiphase mixture by perhaps 10 to 30% and thereby effectively shift the multiphase mixture beyond the unstable heating region and up to the stable film heating region.

  7. [Coronary artery bypass grafting without use of cardiopulmonary bypass].

    PubMed

    Mujanović, Emir; Bergsland, Jacob; Hadziselimović, Mehdin; Softić, Muniba; Azabagic, Azur; Stanimirović-Mujanović, Sanja; Kabil, Emir

    2002-01-01

    Although it is possible to find a number of comparative studies in the world literature discussing the results of coronary artery bypass surgery (CABG) with and without cardiopulmonary bypass (CPB), until now such analysis has not been made in Bosnia and Herzegovina. The main aim of this scientific work was to compare morbidity and mortality, need for blood transfusions, length of stay in the intensive care unit and total length of hospitalisation in two groups of patients operated with these methods. One hundred and four patients with coronary artery disease operated in Cardiovascular Clinic Tuzla, from September, 1998 to September 2002 divided in two groups, were included in this study. There were 52 patients in the first group operated with CPB and 52 patients in the second group operated without CPB. The groups were matched for gender, age, ejection fraction and preoperative risk factors. The incidence of postoperative complications was lower in patients operated without CPB (5.77% vs. 21.15%). The mortality rate was reduced in patients operated without CPB (0.00% vs. 5.76%). There were reduced need for transfusion in patients operated without CPB (0.28 vs. 1.11 units of blood). The average time spent on respirators was shorter in patients operated without CPB (1.50 vs. 4.76 hours). The average time of total hospitalisation was also shorter in patients operated withouth CPB (6.53 vs. 8.13 days). In conclusion CABG without CPB has many advantages compared to the conventional method. Mortality and morbidity are reduced and there is less need for transfusion. The time spent on mechanical ventilation is reduced and less time is spent in intensive care and the total hospitalisation time is also less.

  8. Bypass Transitional Flow Calculations Using a Navier-Stokes Solver and Two-Equation Models

    NASA Technical Reports Server (NTRS)

    Liuo, William W.; Shih, Tsan-Hsing; Povinelli, L. A. (Technical Monitor)

    2000-01-01

    Bypass transitional flows over a flat plate were simulated using a Navier-Stokes solver and two equation models. A new model for the bypass transition, which occurs in cases with high free stream turbulence intensity (TI), is described. The new transition model is developed by including an intermittency correction function to an existing two-equation turbulence model. The advantages of using Navier-Stokes equations, as opposed to boundary-layer equations, in bypass transition simulations are also illustrated. The results for two test flows over a flat plate with different levels of free stream turbulence intensity are reported. Comparisons with the experimental measurements show that the new model can capture very well both the onset and the length of bypass transition.

  9. Treatment of Venous Aortorenal Bypass Graft Aneurysm Using a Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Novotny, Jiri, E-mail: jino@medicon.cz; Peregrin, Jan H.; Stribrna, Jarmila

    2010-02-15

    We present the case of a 77-year-old male patient who had undergone a bilateral venous aortorenal bypass graft 30 years previously. Thirteen years previously, the patient was shown to have a decrease in renal function, with mild shrinking of both kidneys; additionally, a stenosis was found in the left proximal anastomosis. At the most recent follow-up visit (1 year previously), ultrasound revealed an aneurysm (42 mm in diameter) of the left renal bypass graft; the finding was confirmed by CT angiography. A significant ostial stenosis of the left renal bypass graft was also confirmed. It was decided to place amore » self-expandable stent-graft into the aneurysm while also attempting to dilate the stenosis. Proximal endoleak after stent-graft placement necessitated the implantation of another, balloon-expandable stent-graft into the bypass graft ostium. Postprocedural angiography and follow-up by CT angiography at 3 months confirmed good patency of the stent-grafts and complete thrombosis of the aneurysmal sac, with preserved kidney perfusion. Renal function remained unaltered, while the hypertension is better controlled.« less

  10. Pure transumbilical SILS gastric bypass with mechanical circular gastrojejunal anastomosis feasibility.

    PubMed

    Pitot, Denis; Takieddine, Mazen; Abbassi, Ziad; Agrafiotis, Apostolos; Bruyns, Laurence; Ceuterick, Michel; Daoudi, Nabil; Dolimont, Amaury; Soulimani, Abdelak; Vaneukem, Pol

    2014-10-01

    Since Wittgrove introduced the laparoscopic version of the gastric bypass in 1994, the interest still remains in the decrease of the abdominal wall trauma in order to optimize the benefits of laparoscopy on postoperative pain, cosmesis, hospital stay, and convalescence in bariatric patients. This work is to report the feasibility of gastric bypass surgery by a pure transumbilical single-incision laparoscopic surgery (SILS) with a mechanical circular gastrojejunal anastomosis. Thirty-four patients (10 males and 24 females) were offered to receive gastric bypass with circular mechanical gastrojejunal anastomosis by Single Incision Laparoscopic Surgery (SILS) using pure transumbilical access. Anastomotic leak occurrence was the primary end-point. Patients demographics, operative time, additional trocarts, hemorrhage, intra abdominal abscess, length of post-operative stay, readmission, 30 days death, gastrojejunal anastomosis stricture, marginal ulcers, reflux complains, seromas, incisional hernias, and % excess BMI loss were also recorded in a prospective database. Primary end-point showed no anastomotic leak occurrence during the hospital stay or during the first 30 post-operative days. SILS gastric bypass with a circular mechanical gastrojejunal anastomosis is feasible and seems to be safe.

  11. Bypass system modification at Bonneville Dam on the Columbia River improved the survival of juvenile salmon

    USGS Publications Warehouse

    Ferguson, J.W.; Sandford, B.P.; Reagan, R.E.; Gilbreath, L.G.; Meyer, E.B.; Ledgerwood, R.D.; Adams, N.S.

    2007-01-01

    From 1987 to 1992, we evaluated a fish bypass system at Bonneville Dam Powerhouse 2 on the Columbia River. The survival of subyearling Chinook salmon Oncorhynchus tshawytscha released into the system ranged from 0.774 to 0.911 and was significantly lower than the survival of test fish released into turbines and the area immediately below the powerhouse where bypass system flow reentered the river. Yearling and subyearling Chinook salmon and yearling coho salmon O. kisutch released into the bypass system were injured or descaled. Also, levels of blood plasma cortisol and lactate were significantly higher in yearling and subyearling Chinook salmon that passed through the bypass system than in fish released directly into a net located over the bypass exit. This original system was then extensively modified using updated design criteria, and the site where juvenile fish reentered the river was relocated 2.8 km further downstream to reduce predation on bypassed fish by northern pikeminnow Ptychocheilus oregonensis. Based on studies conducted from 1999 to 2001, the new bypass system resulted in high fish survival, virtually no injuries to fish, fish passage times that were generally similar to water travel times, and mild stress responses from which fish recovered quickly. The mean estimated survival of subyearling Chinook salmon passing through the new bypass system was 0.946 in 2001, which was an usually low-flow year. Survival, physical condition, passage timing, and blood physiological indicators of stress were all useful metrics for assessing the performance of both bypass systems and are discussed. The engineering and hydraulic criteria used to design the new bypass system that resulted in improved fish passage conditions are described.

  12. The Straight Path to Healing: Using Motivational Interviewing to Address Spiritual Bypass

    ERIC Educational Resources Information Center

    Clarke, Philip B.; Giordano, Amanda L.; Cashwell, Craig S.; Lewis, Todd F.

    2013-01-01

    Spiritual bypass is the avoidance of underlying emotional issues by focusing solely on spiritual beliefs, practices, and experiences. Motivational interviewing (MI) is a client-centered, compassionate approach to effectively addressing resistance among those who present with spiritual bypass. In this article, the authors provide background…

  13. Lesion bypass by S. cerevisiae Pol ζ alone

    PubMed Central

    Stone, Jana E.; Kumar, Dinesh; Binz, Sara K.; Inase, Aki; Iwai, Shigenori; Chabes, Andrei; Burgers, Peter M.; Kunkel, Thomas A.

    2011-01-01

    DNA polymerase zeta (Pol ζ) participates in translesion synthesis (TLS) of DNA adducts that stall replication fork progression. Previous studies have led to the suggestion that the primary role of Pol ζ in TLS is to extend primers created when another DNA polymerase inserts nucleotides opposite lesions. Here we test the non-exclusive possibility that Pol ζ can sometimes perform TLS in the absence of any other polymerase. To do so, we quantified the efficiency with which S. cerevisiae Pol ζ bypasses abasic sites, cis-syn cyclobutane pyrimidine dimers and (6-4) photoproducts. In reactions containing dNTP concentrations that mimic those induced by DNA damage, a Pol ζ derivative with phenylalanine substituted for leucine 979 at the polymerase active site bypasses all three lesions at efficiencies between 27–73%. Wild-type Pol ζ also bypasses these lesions, with efficiencies that are lower and depend on the sequence context in which the lesion resides. The results are consistent with the hypothesis that, in addition to extending aberrant termini created by other DNA polymerases, Pol ζ has the potential to be the sole DNA polymerase involved in TLS. PMID:21622032

  14. Cerebral activation of mitogen-activated protein kinases after circulatory arrest and low flow cardiopulmonary bypass.

    PubMed

    Aharon, Alon S; Mulloy, Matthew R; Drinkwater, Davis C; Lao, Oliver B; Johnson, Mahlon D; Thunder, Megan; Yu, Chang; Chang, Paul

    2004-11-01

    Mitogen-activated protein kinases (MAPK) are important intermediates in the signal transduction pathways involved in neuronal dysfunction following cerebral ischemia-reperfusion injury. One subfamily, extracellular regulated kinase 1/2, has been heavily implicated in the pathogenesis of post-ischemic neuronal damage. However, the contribution of extracellular regulated kinase 1/2 to neuronal damage following deep hypothermic circulatory arrest and low flow cardiopulmonary bypass is unknown. We attempted to correlate the extent of neuronal damage present following deep hypothermic circulatory arrest and low flow cardiopulmonary bypass with phosphorylated extracellular regulated kinase 1/2 expression in the cerebral vascular endothelium. Piglets underwent normal flow cardiopulmonary bypass (n=4) deep hypothermic circulatory arrest (n=6) and low flow cardiopulmonary bypass (n=5). Brains were harvested following 24 h of post-cardiopulmonary bypass recovery. Cerebral cortical watershed zones, hippocampus, basal ganglia, thalamus, cerebellum, mesencephalon, pons and medulla were evaluated using hematoxylin and eosin staining. A section of ischemic cortex was evaluated by immunohistochemistry with rabbit polyclonal antibodies against phosphorylated extracellular regulated kinase 1/2. Compared to cardiopulmonary bypass controls, the deep hypothermic circulatory arrest and low flow cardiopulmonary bypass piglets exhibited diffuse ischemic changes with overlapping severity and distribution. Significant neuronal damage occurred in the frontal watershed zones and basal ganglia of the deep hypothermic circulatory arrest group (P<0.05). No detectable phosphorylated extracellular regulated kinase 1/2 immunoreactivity was found in the cardiopulmonary bypass controls; however, ERK 1/2 immunoreactivity was present in the cerebral vascular endothelium of the deep hypothermic circulatory arrest and low flow cardiopulmonary bypass groups. Our results indicate that phosphorylated

  15. Water-induced nanochannel networks in self-assembled block ionomers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mineart, Kenneth P.; Al-Mohsin, Heba A.; Lee, Byeongdu

    2016-03-07

    Block ionomers cast from solution exhibit solvent-templated morphologies that can be altered by solvent-vapor annealing. When cast from a mixed solvent, a midblock-sulfonated pentablock ion- omer self-assembles into spherical ionic microdomains that are loosely connected. Upon exposure to liquid water, nanoscale channels irreversibly develop between the microdomains due to swelling and form a continuous mesoscale network. We use electron tomography and real-time X-ray scat- tering to follow this transformation and show that the resultant morphology provides a highly effec- tive diffusive pathway.

  16. Oil Bypass Filter Technology Evaluation - Third Quarterly Report, April--June 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurence R. Zirker; James E. Francfort

    2003-08-01

    This Third Quarterly report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy’s FreedomCAR & Vehicle Technologies Program. Eight full-size, four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass filter systems from the PuraDYN Corporation. The reported engine lubricating oil-filtering capability (down to 0.1 microns) and additive package of the bypass filter system is intended to extend oil-drain intervals. To validate the extended oil-drain intervals, an oil-analysis regime monitors the presence of necessary additives inmore » the oil, detects undesirable contaminants and engine wear metals, and evaluates the fitness of the oil for continued service. The eight buses have accumulated 185,000 miles to date without any oil changes. The preliminary economic analysis suggests that the per bus payback point for the oil bypass filter technology should be between 108,000 miles when 74 gallons of oil use is avoided and 168,000 miles when 118 gallons of oil use is avoided. As discussed in the report, the variation in the payback point is dependant on the assumed cost of oil. In anticipation of also evaluating oil bypass systems on six Chevrolet Tahoe sport utility vehicles, the oil is being sampled on the six Tahoes to develop an oil characterization history for each engine.« less

  17. [How to facilitate protein consumption after gastric bypass?].

    PubMed

    Clarisse, Muriel; Di Vetta, Véronique; Siegrist, Carine; Giusti, Vittorio

    2013-03-27

    After a gastric bypass, covering protein needs is impossible. This deficit is co-responsible for several postoperative complications so it is essential to inform, prepare and train every patient candidate for such an intervention. To increase protein intake, it is important to work on two different aspects: on the one hand on food sources, targeting the richest food and, on the other hand, on food tolerance so that these foods can be consumed. In fact, gastric bypass induces not only a reduction in gastric volume, but also reduces the passage from the stomach to the intestine. Changes in feeding behavior are much needed to improve food tolerance.

  18. Whispering gallery mode photoemission from self-assembled poly-para-phenylenevinylene microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kushida, Soh; Yamamoto, Yohei; Braam, Daniel

    2015-12-31

    Poly[2-methoxy-5-(3,7-dimethyloctyloxy)-1,4-phenylenevinylene] (MDMOPPV) self-assembles to form well-defined spheres with several micrometers in diameter upon addition of a methanol vapor into a chloroform solution of MDMOPPV. The single sphere of MDMOPPV with 5.7 µm diameter exhibits whispering gallery mode (WGM) photoemission upon excitation with focused laser beam. The periodic emission lines are characterized by transverse electric and magnetic WGMs, and Q-factor reaches ∼345 at the highest.

  19. [Prevention of side effects and complications after operation for partial ileal bypass].

    PubMed

    Mirchuk, K K; Sedletskiĭ, Iu I

    2014-01-01

    Side effects and complications of the application of partial ileal bypass used for dislipidemia were analyzed in 162 patients with atherosclerosis. It was shown, that the partial ileal bypass operation could lead to the development of series of undesirable side effects such as diarrhea, hypovitaminosis B12, off-state intestine enteritis. The application of modification of partial ileal bypass such as formation of ileo-ileoanastomosis 5-6 cm long near ileocecal valve with the maintenance of its functions disposed the diarrhea and minimized the risk of the development of hypovitaminosis B12 after operation. It is possible to prevent the development of enteritis of off-state loop of the small intestine by using microanastomosis between off-state and functioning iliac intestine. The partial ileal bypass operation didn't influence on body weight, wouldn't increase the risk of stone formation in the gallbladder and kidneys. The risk of the development of hypovitaminosis B12 is minimal after operation.

  20. Active bypass flow control for a seal in a gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebert, Todd A.; Kimmel, Keith D.

    An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wearsmore » In at least one embodiment, the metering device may include an annular ring having at least one metering orifice extending therethrough, whereby alignment of the metering orifice with the outlet may be adjustable to change a cross-sectional area of an opening of aligned portions of the outlet and the metering orifice.« less

  1. Construct exploit constraint in crash analysis by bypassing canary

    NASA Astrophysics Data System (ADS)

    Huang, Ning; Huang, Shuguang; Huang, Hui; Chang, Chao

    2017-08-01

    Selective symbolic execution is a common program testing technology. Developed on the basis of it, some crash analysis systems are often used to test the fragility of the program by constructing exploit constraints, such as CRAX. From the study of crash analysis based on symbolic execution, this paper find that this technology cannot bypass the canary stack protection mechanisms. This paper makes the improvement uses the API hook in Linux. Experimental results show that the use of API hook can effectively solve the problem that crash analysis cannot bypass the canary protection.

  2. Perforated marginal ulcers after laparoscopic gastric bypass.

    PubMed

    Felix, Edward L; Kettelle, John; Mobley, Elijah; Swartz, Daniel

    2008-10-01

    Perforated marginal ulcer (PMU) after laparoscopic Roux-en-Y gastric bypass (LRYGB) is a serious complication, but its incidence and etiology have rarely been investigated. Therefore, a retrospective review of all patients undergoing LRYGB at the authors' center was conducted to determine the incidence of PMU and whether any causative factors were present. A prospectively kept database of all patients at the authors' bariatric center was retrospectively reviewed. The complete records of patients with a PMU were examined individually for accuracy and analyzed for treatment, outcome, and possible underlying causes of the marginal perforation. Between April 1999 and August 2007, 1% of the patients (35/3,430) undergoing laparoscopic gastric bypass experienced one or more perforated marginal ulcers 3 to 70 months (median, 18 months) after LRYGB. The patients with and without perforation were not significantly different in terms of mean age (37 vs 41 years), weight (286 vs 287 lb), body mass index (BMI) (46 vs 47), or female gender (89% vs 83%). Of the patients with perforations, 2 (6%) were taking steroids, 10 (29%) were receiving nonsteroidal antiinflammatory drugs (NSAIDs) at the time of the perforation, 18 (51%) were actively smoking, and 6 of the smokers also were taking NSAIDs. Eleven of the patients (31%) who perforated did not have at least one of these possible risk factors, but 4 (36%) of the 11 patients in this group had been treated after bypass for a marginal ulcer. Only 7 (20%) of the 35 patients who had laparoscopic bypass, or 7 (0.2%) in the entire group of 3,430 patients, perforated without any warning. There were no deaths, but three patients reperforated. The incidence of a marginal ulcer perforating after LRYGB was significant (>1%) and appeared to be related to smoking or the use of NSAIDs or steroids. Because only 0.2% of all patients acutely perforated without some risk factor or warning, long-term ulcer prophylaxis or treatment may be necessary

  3. Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device.

    PubMed

    Tedoriya, T; Kawasuji, M; Sakakibara, N; Takemura, H; Watanabe, Y; Hetzer, R

    1998-08-01

    Intraaortic balloon pumping (IABP) and left ventricular assist device (LVAD) are used for left ventricular support when low cardiac output occurs after a coronary bypass operation for serious coronary artery disease. There are hemodynamic differences in blood flow in various kinds of coronary artery bypass grafts, caused by their inherent physiologic characteristics. The hemodynamic effects of left ventricular assistance with IABP and LVAD on blood flow through various coronary artery bypass grafts were investigated. An ascending aorta-coronary bypass graft (ACB), an internal thoracic artery, and a descending aorta-coronary bypass graft were anastomosed to the left anterior descending coronary artery in a canine model. In this experimental model, the blood flow to the same coronary bed in the three types of grafts could be evaluated. Blood flow in the left anterior descending coronary artery through the three types of coronary bypass grafts was studied in this model during or in the absence of ventricular assistance. In the control study, the systolic blood flow did not differ among the three types of grafts, but the diastolic flow decreased in the following order: with the ACB, the internal thoracic artery, and the descending aorta-coronary bypass graft. The systolic flow during IABP and LVAD was similar to the control flows. Use of IABP increased the diastolic flow by 75.3%+/-12.4% of the control value in the ACB, 37.9%+/-25.0% in the internal thoracic artery, and 21.2%+/-11.4% in the descending aorta-coronary bypass graft. The LVAD increased the diastolic flow by 97.7%+/-18.7% of the control value in the ACB, 64.5%+/-25.7% in the internal thoracic artery, and 63.0%+/-27.9% in the descending aorta-coronary bypass graft. The diastolic blood flows in the left anterior descending coronary artery and the three types of grafts were significantly greater with IABP than the control values, and significantly greater with LVAD than with IABP and the control values. The

  4. Vapor generator wand

    NASA Technical Reports Server (NTRS)

    Robelen, David B. (Inventor)

    1996-01-01

    A device for producing a stream of vapor for wind tunnel airflow visualization is described. An electrically conductive heating tube is used to resistively heat a vapor producing liquid. The heating and delivery systems are integrated to allow the device to present a small cross section to the air flow, thereby reducing disturbances due to the device. The simplicity of the design allows for inexpensive implementation and construction. The design is readily scaled for use in various wind tunnel applications. The device may also find uses in manufacturing, producing a vapor for deposition on a substrate.

  5. 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

    PubMed

    Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Murai, Yasuo; Orita, Erika; Matsumura, Yoshio; Kumita, Shin-Ichiro

    2016-03-01

    Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass. We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery. 4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R (2) = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively. 4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.

  6. Vapor spill monitoring method

    DOEpatents

    Bianchini, Gregory M.; McRae, Thomas G.

    1985-01-01

    Method for continuous sampling of liquified natural gas effluent from a spill pipe, vaporizing the cold liquified natural gas, and feeding the vaporized gas into an infrared detector to measure the gas composition. The apparatus utilizes a probe having an inner channel for receiving samples of liquified natural gas and a surrounding water jacket through which warm water is flowed to flash vaporize the liquified natural gas.

  7. Coronary Artery Bypass Surgery - Multiple Languages

    MedlinePlus

    ... Bypass Surgery - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section Coronary ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section Coronary ...

  8. Retrospective Analyses of Esophageal Bypass Surgery for Patients with Esophagorespiratory Fistulas Caused by Esophageal Carcinomas.

    PubMed

    Nakajima, Yasuaki; Kawada, Kenro; Tokairin, Yutaka; Miyawaki, Yutaka; Okada, Takuya; Miyake, Satoshi; Kawano, Tatsuyuki

    2016-05-01

    Esophagorespiratory fistula (ERF) caused by esophageal carcinoma is a fatal complication. In our institution, esophageal bypass surgery has been indicated when possible. We herein retrospectively describe the clinical results of esophageal bypass surgery for ERF. Between April 2001 and March 2015, 20 patients with ERF underwent esophageal bypass surgery. For these patients, the clinical safety, validity, and effectiveness of esophageal bypass surgery were examined and compared with the results of bypass surgery without ERF. Eight patients developed ERF at the initial diagnosis, while 10 patients developed ERF during and after chemoradiotherapy. Postoperative complications such as pneumonia, surgical site infection, and anastomotic leakage developed in 12, 5, and 1 patient, respectively. All the patients could eat solid foods at a median of 9 postoperative days. Two patients died within 30 days after the operation and 1 patient developed in-hospital death. Fourteen patients received chemo(radio)therapy after the operation. The median overall survival was 244 days and the one-year and three-year overall survival rates were 45.7 and 15.3 %, respectively. There was no significant difference in terms of the intraoperative findings, postoperative morbidities, and short-term and long-term clinical results between the two groups. Esophageal bypass surgery for ERF is not considered to be highly invasive or risky compared with bypass surgery without ERF. After the operation, respiratory symptoms caused by ERF may improve and oral intake can be achieved. Esophageal bypass surgery should therefore be aggressively performed for patients with a tolerable performance status.

  9. Piezoelectric trace vapor calibrator

    NASA Astrophysics Data System (ADS)

    Verkouteren, R. Michael; Gillen, Greg; Taylor, David W.

    2006-08-01

    The design and performance of a vapor generator for calibration and testing of trace chemical sensors are described. The device utilizes piezoelectric ink-jet nozzles to dispense and vaporize precisely known amounts of analyte solutions as monodisperse droplets onto a hot ceramic surface, where the generated vapors are mixed with air before exiting the device. Injected droplets are monitored by microscope with strobed illumination, and the reproducibility of droplet volumes is optimized by adjustment of piezoelectric wave form parameters. Complete vaporization of the droplets occurs only across a 10°C window within the transition boiling regime of the solvent, and the minimum and maximum rates of trace analyte that may be injected and evaporated are determined by thermodynamic principles and empirical observations of droplet formation and stability. By varying solution concentrations, droplet injection rates, air flow, and the number of active nozzles, the system is designed to deliver—on demand—continuous vapor concentrations across more than six orders of magnitude (nominally 290fg/lto1.05μg/l). Vapor pulses containing femtogram to microgram quantities of analyte may also be generated. Calibrated ranges of three explosive vapors at ng/l levels were generated by the device and directly measured by ion mobility spectrometry (IMS). These data demonstrate expected linear trends within the limited working range of the IMS detector and also exhibit subtle nonlinear behavior from the IMS measurement process.

  10. Directed assembly of carbon nanotubes on soft substrates for use as a flexible biosensor array.

    PubMed

    Koh, Juntae; Yi, Mihye; Yang Lee, Byung; Kim, Tae Hyun; Lee, Joohyung; Jhon, Young Min; Hong, Seunghun

    2008-12-17

    We have developed a method to selectively assemble and align carbon nanotubes (CNTs) on soft substrates for use as flexible biosensors. In this strategy, a thin oxide layer was deposited on soft substrates via low temperature plasma enhanced chemical vapor deposition, and a linker-free assembly process was applied on the oxide surface where the assembly of carbon nanotubes was guided by methyl-terminated molecular patterns on the oxide surface. The electrical characterization of the fabricated CNT devices exhibited a typical p-type gating effect and 1/f noise behavior. The bare oxide regions near CNTs were functionalized with glutamate oxidase to fabricate selective biosensors to detect two forms of glutamate substances existing in different situations: L-glutamic acid, a neurotransmitting material, and monosodium glutamate, a food additive.

  11. Cure with ledipasvir/sofosbuvir for chronic hepatitis C virus in an individual with gastric bypass.

    PubMed

    Johnson, S W; Teachey, A L; Valanejad, S M; Griffin, S M; Weber, S F

    2017-10-01

    The impact of gastric bypass surgery on the pharmacokinetics of various medications has been reported. Presently, no data exist for the treatment of chronic hepatitis C virus with ledipasvir/sofosbuvir (LDV/SOF) in an individual with a history of gastric bypass. We report the successful cure of an individual who was treated with LDV/SOF who had a history of gastric bypass. The patient tolerated LDV/SOF well while only experiencing a minor headache. Ledipasvir/sofosbuvir treatment may still be effective in those with a history of gastric bypass surgery. © 2017 John Wiley & Sons Ltd.

  12. Elevated fasting and postprandial C-terminal telopeptide after Roux-en-Y gastric bypass.

    PubMed

    Maghsoodi, Negar; Alaghband-Zadeh, Jamshid; Cross, Gemma F; Werling, Malin; Fändriks, Lars; Docherty, Neil G; Olbers, Torsten; Dew, Tracy; Sherwood, Roy A; Vincent, Royce P; le Roux, Carel W

    2017-07-01

    Background Roux-en-Y gastric bypass increases circulating bile acid concentrations, known mediators of postprandial suppression of markers of bone resorption. Long-term data, however, indicate that Roux-en-Y gastric bypass confers an increased risk of bone loss on recipients. Methods Thirty-six obese individuals, median age 44 (26-64) with median body mass index at baseline of 42.5 (40.4-46) were studied before and 15 months after Roux-en-Y gastric bypass. After an overnight fast, patients received a 400 kcal mixed meal. Blood samples were collected premeal then at 30-min periods for 120 min. Pre and postmeal samples were analysed for total bile acids, parathyroid hormone and C-terminal telopeptide. Results Body weight loss post Roux-en-Y gastric bypass was associated with a median 4.9-fold increase in peak postprandial total bile acid concentration, and a median 2.4-fold increase in cumulative food evoked bile acid response. Median fasting parathyroid hormone, postprandial reduction in parathyroid hormone and total parathyroid hormone release over 120 min remained unchanged after surgery. After surgery, median fasting C-terminal telopeptide increased 2.3-fold, peak postprandial concentrations increased 3.8-fold and total release was increased 1.9-fold. Conclusions Fasting and postprandial total bile acids and C-terminal telopeptide are increased above reference range after Roux-en-Y gastric bypass. These changes occur in spite of improved vitamin D status with supplementation. These results suggest that post-Roux-en-Y gastric bypass increases in total bile acids do not effectively oppose an ongoing resorptive signal operative along the gut-bone axis. Serial measurement of C-terminal telopeptide may be of value as a risk marker for long-term skeletal pathology in patients post Roux-en-Y gastric bypass.

  13. Holographic studies of the vapor explosion of vaporizing water-in-fuel emulsion droplets

    NASA Technical Reports Server (NTRS)

    Sheffield, S. A.; Hess, C. F.; Trolinger, J. D.

    1982-01-01

    Holographic studies were performed which examined the fragmentation process during vapor explosion of a water-in-fuel (hexadecane/water) emulsion droplet. Holograms were taken at 700 to 1000 microseconds after the vapor explosion. Photographs of the reconstructed holograms reveal a wide range of fragment droplet sizes created during the explosion process. Fragment droplet diameters range from below 10 microns to over 100 microns. It is estimated that between ten thousand and a million fragment droplets can result from this extremely violent vapor explosion process. This enhanced atomization is thus expected to have a pronounced effect on vaporization processes which are present during combustion of emulsified fuels.

  14. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    PubMed

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  15. Heterotopic pancreas in excluded stomach diagnosed after gastric bypass surgery

    PubMed Central

    2013-01-01

    Background Heterotopic pancreas is defined as finding of pancreatic tissue without anatomic and vascular continuity with the normal pancreas. Heterotopic pancreas is a rare condition difficult to diagnose and with controversial clinical management. Case presentation We describe a 43 year old female patient previously submitted to laparoscopic gastric bypass for primary treatment of morbid obesity; 5 years later, the patient was discovered to have a mass in the antrum of the excluded stomach that was found to be heterotopic pancreatic tissue. Before gastric bypass surgery, the presence of the pancreatic mass in the gastric wall was unnoticed in the imagiologic records. Conclusion This is the first reported case of pancreatic heterotopy diagnosed in the excluded stomach after gastric bypass. A putative role of incretin hormones in mediating pancreatic cell hyperplasia of heterotopic pancreatic remnants should be considered an additional hypothesis that requires further research. PMID:24267291

  16. Development Status of the International Space Station Urine Processor Assembly

    NASA Technical Reports Server (NTRS)

    Holder, Donald W.; Hutchens, Cindy F.

    2003-01-01

    NASA, Marshall Space Flight Center (MSFC) is developing a Urine Processor Assembly (UPA) for the International Space Station (ISS). The UPA uses Vapor Compression Distillation (VCD) technology to reclaim water from pre-treated urine. This water is further processed by the Water Processor Assembly (WPA) to potable quality standards for use on the ISS. NASA has developed this technology over the last 25-30 years. Over this history, many technical issues were solved with thousands of hours of ground testing that demonstrate the ability of the UPA technology to reclaim water from urine. In recent years, NASA MSFC has been responsible for taking the UPA technology to "flight design" maturity. This paper will give a brief overview of the UPA design and a status of the major design and development efforts completed recently to mature the UPA to a flight level.

  17. Structure-function analysis of ribonucleotide bypass by B family DNA replicases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clausen, Anders R.; Murray, Michael S.; Passer, Andrew R.

    2013-11-01

    Ribonucleotides are frequently incorporated into DNA during replication, they are normally removed, and failure to remove them results in replication stress. This stress correlates with DNA polymerase (Pol) stalling during bypass of ribonucleotides in DNA templates. Here we demonstrate that stalling by yeast replicative Pols δ and ε increases as the number of consecutive template ribonucleotides increases from one to four. The homologous bacteriophage RB69 Pol also stalls during ribonucleotide bypass, with a pattern most similar to that of Pol ε. Crystal structures of an exonuclease-deficient variant of RB69 Pol corresponding to multiple steps in single ribonucleotide bypass reveal thatmore » increased stalling is associated with displacement of Tyr391 and an unpreferred C2´-endo conformation for the ribose. Even less efficient bypass of two consecutive ribonucleotides in DNA correlates with similar movements of Tyr391 and displacement of one of the ribonucleotides along with the primer-strand DNA backbone. These structure–function studies have implications for cellular signaling by ribonucleotides, and they may be relevant to replication stress in cells defective in ribonucleotide excision repair, including humans suffering from autoimmune disease associated with RNase H2 defects.« less

  18. EARLY POSTOPERATIVE COMPLICATIONS IN ROUX-EN-Y GASTRIC BYPASS

    PubMed Central

    STOLL, Aluisio; ROSIN, Leandro; DIAS, Mariana Fernandes; MARQUIOTTI, Bruna; GUGELMIN, Giovana; STOLL, Gabriela Fanezzi

    2016-01-01

    ABSTRACT Background: Roux-en-Y gastric bypass is one of the most common bariatric surgery and leads to considerable weight loss in the first months. Aim: To quantify the main early postoperative complications in patients submitted to the gastric bypass. Method: Observational retrospective cohort. Data of 1051 patients with class II obesity associated with comorbidities or class III obesity submitted to the gastric bypass with 30 days of follow-up starting from the date of the surgery. Results: The age average was 36 years with a predominance of females (81.1%). The mean preoperative body mass index was 43 kg/m². The major complication was fistula (2.3%), followed by intestinal obstruction (0.5%) and pulmonary embolism (0.5%). Death occurred in 0.6% of the cases. Conclusion: In the period of 30 days after surgery the overall complication rate was 3.8%; reoperation was necessary in 2.6% and death occurred in 0.6%. Fistula was the main complication and the leading cause of hospitalization in intensive care unit, reoperation and death. PMID:27683781

  19. Resource Utilization Related to Atrial Fibrillation After Coronary Artery Bypass Grafting

    PubMed Central

    Hravnak, Marilyn; Hoffman, Leslie A.; Saul, Melissa I.; Zullo, Thomas G.; Whitman, Gayle R.

    2013-01-01

    Background Studies of resource utilization by patients with new-onset atrial fibrillation after coronary artery bypass grafting have addressed only length of stay and bed charges. Objective To compare resource utilization between patients with new-onset atrial fibrillation and patients without atrial fibrillation after isolated coronary artery bypass grafting. Methods Retrospective review of clinical and administrative electronic databases for 720 subjects who underwent isolated coronary artery bypass grafting with cardiopulmonary bypass in 25 months at one medical center. The prevalence of atrial fibrillation was determined, and resource utilization in various hospital cost centers was compared between subjects with and without atrial fibrillation. Results The prevalence of new-onset atrial fibrillation was 33.1%. Compared with subjects without atrial fibrillation, subjects with atrial fibrillation had a longer stay (5.8 ± 2.4 vs 4.4 ± 1.2 days, P< .001), more days receiving mechanical ventilation (P=.002) and oxygen therapy (P< .001), and higher rates of readmission to the intensive care unit (4.6% vs 0.2%, P< .001). Subjects with atrial fibrillation also had more laboratory tests (P< .001) and more days receiving cardiac drugs, heparin, diuretics, and electrolytes. Subjects with atrial fibrillation had higher total postoperative charges ($57261 ± $17 101 vs $50905 ± $10062, P= .001), a mean difference of $6356. The mean differences were greatest for bed charges ($1642), laboratory charges ($1215), pharmacy ($989), and respiratory care ($582). Conclusion The economic impact of atrial fibrillation after coronary artery bypass grafting has been underestimated. PMID:12022486

  20. [Arterial bypass iterative thrombosis and cancer: three cases].

    PubMed

    Villemur, B; Payraud, E; Seetha, V; De Angelis, M-P; Magne, J L; Perennou, D; Carpentier, P; Pernod, G

    2014-02-01

    Cancer associated with venous thromboembolic disease has been recognized since Trousseau, but a link between cancer and iterative arterial thrombosis is rarely described. We report three cases of patients with iterative bypass thrombosis in whom cancer was subsequently diagnosed: lung cancer in one patient and hepatocarcinoma and bladder cancer in the others. Smoking and hypertension were risk factors in both patients. The link between arterial thrombosis and cancer is probably multifactorial. In case of iterative arterial bypass thrombosis, the search for cancer is as useful as the control of cardiovascular risk factors and the search for antiphospholipid syndrome, since patient management can be affected. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Phaeochromocytoma presenting with labile blood pressures following coronary artery bypass grafting.

    PubMed

    Roy, James; Akhunji, Zakir; Kushwaha, Virag; Mackie, James; Jepson, Nigel

    2016-12-01

    Pheochromocytomas have been reported prior to and during coronary artery bypass surgery. We present a patient with an undiagnosed pheochromocytoma who presented with labile hypertension following coronary artery bypass surgery. This case calls attention to the inclusion of an undiagnosed pheochromocytoma in the differential diagnosis for all patients who develop labile hypertension in the postoperative period following cardiac surgery. © 2016 Wiley Periodicals, Inc.

  2. SOFIA Water Vapor Monitor Design

    NASA Technical Reports Server (NTRS)

    Cooper, R.; Roellig, T. L.; Yuen, L.; Shiroyama, B.; Meyer, A.; Devincenzi, D. (Technical Monitor)

    2002-01-01

    The SOFIA Water Vapor Monitor (WVM) is a heterodyne radiometer designed to determine the integrated amount of water vapor along the telescope line of sight and directly to the zenith. The basic technique that was chosen for the WVM uses radiometric measurements of the center and wings of the 183.3 GHz rotational line of water to measure the water vapor. The WVM reports its measured water vapor levels to the aircraft Mission Controls and Communication System (MCCS) while the SOFIA observatory is in normal operation at flight altitude. The water vapor measurements are also available to other scientific instruments aboard the observatory. The electrical, mechanical and software design of the WVM are discussed.

  3. Non-Ballistic Vapor-Driven Ejecta

    NASA Technical Reports Server (NTRS)

    Wrobel, K. E.; Schultz, P. H.; Heineck, J. T.

    2004-01-01

    Impact-induced vaporization is a key component of early-time cratering mechanics. Previous experimental [1,2] and computational [e.g., 3] studies focused on the generation and expansion of vapor clouds in an attempt to better understand vaporization in hypervelocity impacts. Presented here is a new experimental approach to the study of impact-induced vaporization. The three-dimensional particle image velocimetry (3D PIV) system captures interactions between expanding vapor phases and fine particulates. Particles ejected early in the cratering process may be entrained in expanding gas phases generated at impact, altering their otherwise ballistic path of flight. 3D PIV allows identifying the presence of such non-ballistic ejecta from very early times in the cratering process.

  4. 21 CFR 868.5880 - Anesthetic vaporizer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthetic vaporizer. 868.5880 Section 868.5880...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5880 Anesthetic vaporizer. (a) Identification. An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled...

  5. 21 CFR 868.5880 - Anesthetic vaporizer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthetic vaporizer. 868.5880 Section 868.5880...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5880 Anesthetic vaporizer. (a) Identification. An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled...

  6. 21 CFR 868.5880 - Anesthetic vaporizer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthetic vaporizer. 868.5880 Section 868.5880...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5880 Anesthetic vaporizer. (a) Identification. An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled...

  7. 21 CFR 868.5880 - Anesthetic vaporizer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthetic vaporizer. 868.5880 Section 868.5880...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5880 Anesthetic vaporizer. (a) Identification. An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled...

  8. 21 CFR 868.5880 - Anesthetic vaporizer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthetic vaporizer. 868.5880 Section 868.5880...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5880 Anesthetic vaporizer. (a) Identification. An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled...

  9. Isopentenyl diphosphate (IPP)-bypass mevalonate pathways for isopentenol production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Aram; George, Kevin W.; Wang, George

    Branched C 5 alcohols are promising biofuels with excellent combustion properties. A mevalonate (MVA)-based isoprenoid biosynthetic pathway for C 5 alcohols was constructed in Escherichia coli using genes from several organisms, and the pathway was optimized to achieve over 50% theoretical yield. Although the MVA pathway is energetically less efficient than the native methylerythritol 4-phosphate (MEP) pathway, implementing the MVA pathway in bacterial hosts such as E. coli is advantageous due to its lack of endogenous regulation. The MVA and MEP pathways intersect at isopentenyl diphosphate (IPP), the direct precursor to isoprenoid-derived C 5 alcohols and initial precursor to longermore » chain terpenes, which makes independent regulation of the pathways difficult. In pursuit of the complete "decoupling" of the MVA pathway from native cellular regulation, we designed novel IPP-bypass MVA pathways for C 5 alcohol production by utilizing promiscuous activities of two enzymes, phosphomevalonate decarboxylase (PMD) and an E. coli-endogenous phosphatase (AphA). These bypass pathways have reduced energetic requirements, are further decoupled from intrinsic regulation, and are free from IPP-related toxicity. In addition to these benefits, we demonstrate that reduced aeration rate has less impact on the bypass pathway than the original MVA pathway. Finally, we showed that performance of the bypass pathway was primarily determined by the activity of PMD. We designed PMD mutants with improved activity and demonstrated titer increases in the mutant strains. These modified pathways would be a good platform for industrial production of isopentenol and related chemicals such as isoprene.« less

  10. Isopentenyl diphosphate (IPP)-bypass mevalonate pathways for isopentenol production

    DOE PAGES

    Kang, Aram; George, Kevin W.; Wang, George; ...

    2015-12-17

    Branched C 5 alcohols are promising biofuels with excellent combustion properties. A mevalonate (MVA)-based isoprenoid biosynthetic pathway for C 5 alcohols was constructed in Escherichia coli using genes from several organisms, and the pathway was optimized to achieve over 50% theoretical yield. Although the MVA pathway is energetically less efficient than the native methylerythritol 4-phosphate (MEP) pathway, implementing the MVA pathway in bacterial hosts such as E. coli is advantageous due to its lack of endogenous regulation. The MVA and MEP pathways intersect at isopentenyl diphosphate (IPP), the direct precursor to isoprenoid-derived C 5 alcohols and initial precursor to longermore » chain terpenes, which makes independent regulation of the pathways difficult. In pursuit of the complete "decoupling" of the MVA pathway from native cellular regulation, we designed novel IPP-bypass MVA pathways for C 5 alcohol production by utilizing promiscuous activities of two enzymes, phosphomevalonate decarboxylase (PMD) and an E. coli-endogenous phosphatase (AphA). These bypass pathways have reduced energetic requirements, are further decoupled from intrinsic regulation, and are free from IPP-related toxicity. In addition to these benefits, we demonstrate that reduced aeration rate has less impact on the bypass pathway than the original MVA pathway. Finally, we showed that performance of the bypass pathway was primarily determined by the activity of PMD. We designed PMD mutants with improved activity and demonstrated titer increases in the mutant strains. These modified pathways would be a good platform for industrial production of isopentenol and related chemicals such as isoprene.« less

  11. Challenges in the Structure Determination of Self-Assembled Metallacages: What Do Cage Cavities Contain, Internal Vapor Bubbles or Solvent and/or Counterions?

    PubMed

    Givelet, Cecile C; Dron, Paul I; Wen, Jin; Magnera, Thomas F; Zamadar, Matibur; Čépe, Klára; Fujiwara, Hiroki; Shi, Yue; Tuchband, Michael R; Clark, Noel; Zbořil, Radek; Michl, Josef

    2016-05-25

    Proving the structures of charged metallacages obtained by metal ion coordination-driven solution self-assembly is challenging, and the common use of routine NMR spectroscopy and mass spectrometry is unreliable. Carefully determined diffusion coefficients from diffusion-ordered proton magnetic resonance (DOSY NMR) for six cages of widely differing sizes lead us to propose a structural reassignment of two molecular cages from a previously favored trimer to a pentamer or hexamer, and another from a trimer to a much higher oligomer, possibly an intriguing tetradecamer. In the former case, strong support for the reassignment to a larger cage is provided by an observation of a slow reversible transformation of the initially formed cage into a smaller but spectrally very similar one upon dilution. In the latter case, freeze-fracture transmission electron micrographs demonstrate that at least some of the solutions are colloidal, and high-resolution electron transmission and atomic force microscopy images are compatible with a tetradecamer but not a trimer. Comparison of solute partial molar volumes deduced from measurement of solution density with volumes anticipated from molecular models argues strongly against the presence of large voids (solvent vapor bubbles) in cages dissolved in nitromethane. The presence of bubbles was previously proposed in an attempt to account for the bilinear nature of the Eyring plot of the rate constant for pyridine ligand edge exchange reaction in one of the cages and for the unusual activation parameters in the high-temperature regime. An alternative interpretation is proposed now.

  12. Reconnaissance Report Yolo Bypass, California

    DTIC Science & Technology

    1992-03-01

    regulate vegetative growth through feeding activity and assist in pollination of many flowering plant species. Restrictions in geographic movement make...pumping plants , leveed bypass floodways, overbank floodway areas, enlarged and improved channels, and dredging in the lower reach of the Sacramento River...80) crossing. Two pumping plants are part of the project, which pump storm drainage, collecting in low areas landside of the levees, into the river

  13. The effect of laparoscopic Roux-en-Y gastric bypass on fibromyalgia.

    PubMed

    Saber, Alan A; Boros, Michael J; Mancl, Tara; Elgamal, Mohamed H; Song, Susrap; Wisadrattanapong, Therawat

    2008-06-01

    Fibromyalgia is a chronic debilitating disorder affecting 3-5% of the US population. Treatment of this disorder is a challenge. The incidental finding of improvement of fibromyalgia following laparoscopic Roux-en-Y gastric bypass stimulated us to study this phenomenon. A retrospective chart review of patients with fibromyalgia who underwent laparoscopic Roux-en-Y gastric bypass. Postoperative decrease in median of BMI from 49.4 to 29.7 was significant (p value = 0.0010). This was associated with statistically significant improvement in median of pain score (p value = 0.0010) and median points of tenderness (p value = 0.0010). Significant weight loss following laparoscopic Roux-en-Y gastric bypass is associated with resolution or improvement of fibromyalgia. Consequently, the bariatric surgeon should be a member of the multidisciplinary team approach for treating fibromyalgia.

  14. AMTEC vapor-vapor series connected cells

    NASA Technical Reports Server (NTRS)

    Underwood, Mark L. (Inventor); Williams, Roger M. (Inventor); Ryan, Margaret A. (Inventor); Nakamura, Barbara J. (Inventor); Oconnor, Dennis E. (Inventor)

    1995-01-01

    An alkali metal thermoelectric converter (AMTEC) having a plurality of cells structurally connected in series to form a septum dividing a plenum into two chambers, and electrically connected in series, is provided with porous metal anodes and porous metal cathodes in the cells. The cells may be planar or annular, and in either case a metal alkali vapor at a high temperature is provided to the plenum through one chamber on one side of the wall and returned to a vapor boiler after condensation at a chamber on the other side of the wall in the plenum. If the cells are annular, a heating core may be placed along the axis of the stacked cells. This arrangement of series-connected cells allows efficient generation of power at high voltage and low current.

  15. Core-shell structure disclosed in self-assembled Cu-Ag nanoalloy particles

    NASA Astrophysics Data System (ADS)

    Tchaplyguine, M.; Andersson, T.; Zhang, Ch.; Björneholm, O.

    2013-03-01

    Core-shell segregation of copper and silver in self-assembled, free nanoparticles is established by means of photoelectron spectroscopy in a wide range of relative Cu-Ag concentrations. These conclusions are based on the analysis of the photon-energy-dependent changes of the Cu 3d and Ag 4d photoelectron spectra. The nanoparticles are formed from mixed Cu-Ag atomic vapor created by magnetron sputtering of a bimetallic sample in a gas-aggregation cluster source. Even at similar Cu and Ag fractions in the primary vapor the surface of the nanoparticles is dominated by silver. Only at low Ag concentration copper appears on the surface of nanoparticles. For the latter case, a threefold decrease in the Ag 4d spin-orbit splitting has been detected. The specific component distribution and electronic structure changes are discussed in connection with the earlier results on Cu-Ag macroscopic and surface alloys.

  16. Solvent vapor collector

    DOEpatents

    Ellison, Kenneth; Whike, Alan S.

    1979-01-30

    A solvent vapor collector is mounted on the upstream inlet end of an oven having a gas-circulating means and intended for curing a coating applied to a strip sheet metal at a coating station. The strip sheet metal may be hot and solvent vapors are evaporated at the coating station and from the strip as it passes from the coating station to the oven. Upper and lower plenums within a housing of the collector are supplied with oven gases or air from the gas-circulating means and such gases or air are discharged within the collector obliquely in a downstream direction against the strip passing through that collector to establish downstream gas flows along the top and under surfaces of the strip so as, in turn, to induct solvent vapors into the collector at the coating station. A telescopic multi-piece shroud is usefully provided on the housing for movement between an extended position in which it overlies the coating station to collect solvent vapors released thereat and a retracted position permitting ready cleaning and adjustment of that coating station.

  17. IMPACT ON DISINFECTION AT PEAK FLOWS DURING BLENDING/PARTIAL BYPASSING OF SECONDARY TREATMENT

    EPA Science Inventory

    A U.S EPA study evaluated the impact on disinfection during peak flows when a portion of the flow to the wastewater treatment plant (WWTP) bypasses secondary treatment prior to disinfection. The practice of bypassing secondary treatment during peak flows, referred to as “blending...

  18. Outcomes of sympathectomy and vascular bypass for digital ischaemia in connective tissue disorders.

    PubMed

    Shammas, R L; Hwang, B H; Levin, L S; Richard, M J; Ruch, D S; Mithani, S K

    2017-10-01

    All patients (36 hands) with connective tissue disorders who underwent periarterial sympathectomy of the hand alone or in conjunction with vascular bypass at our institution between 1995-2013 were reviewed. The durable resolution of ulcers was significantly higher in patients treated by periarterial sympathectomy and bypass than in patients treated by periarterial sympathectomy alone. Although there were more digital amputations in patients treated by periarterial sympathectomy alone, the difference was not statistically significant. Vascular bypass in conjunction with sympathectomy may be better than sympathectomy alone in patients with digital ischaemia related to connective tissue disorders. IV.

  19. Robotic totally endoscopic triple coronary artery bypass grafting on the arrested heart: report of the first successful clinical case.

    PubMed

    Bonatti, Johannes; Rehman, Atiq; Schwartz, Kimberly; Deshpande, Seema; Kon, Zachary; Lehr, Eric; Zimrin, David; Griffith, Bartley

    2010-12-01

    Robotic technology enables "port only" totally endoscopic coronary artery bypass grafting (TECAB). During early procedure development only single bypass grafts were feasible. Because current referral practice for coronary bypass surgery mostly includes multivessel disease, performance of multiple endoscopic bypass grafts is desirable. We report a case in which a patient received a right internal mammary artery bypass graft to the left anterior descending artery and a left internal mammary artery jump graft to 2 obtuse marginal branches. The procedure was performed through 5 ports on the arrested heart using the daVinci S robotic surgical system. This is the first reported triple bypass grafting procedure using an arrested heart approach.

  20. DIET MICRONUTRIENT ADEQUACY OF WOMEN AFTER 1 YEAR OF GASTRIC BYPASS

    PubMed Central

    LEIRO, Larissa Silveira; Melendez-ARAÚJO, Mariana Silva

    2014-01-01

    Background The more effective treatment for severe obesity is bariatric surgery. Gastric bypass is a surgical technique used worldwide; however, as well as other techniques; it has postoperative risks, including nutrient deficiency. Aim To determine the amounts of dietary iron, calcium, vitamin D and vitamin B12 ingested by patients of a public hospital one year after gastric bypass, and compare with the recommendations of the Recommended Dietary Allowances. Methods This was a transverse descriptive study and the sample consisted of 36 women, with at least one year of gastric bypass. Data collected included sociodemographic, anthropometric and diet variables. Dietetic information was collected through a validated food frequency questionnaire. Ingestion of iron, calcium, vitamin D and vitamina B12 was evaluated in comparison with the Recommended Dietary Allowances, as well as correlation of micronutrient ingestion with time of surgery. Results There was inadequate consumption of iron, calcium and vitamin D. The vitamin B12 intake was considered adequate. There was statistically significant positive correlation between the time of surgery and the ingestion of iron, vitamin B12 and vitamin D. Conclusion The intake of iron, calcium and vitamin D of women one year after gastric bypass was inadequate, emphasizing the importance of multiprofessional monitoring postoperatively to prevent nutrient deficiencies. PMID:25409960

  1. A heated vapor cell unit for dichroic atomic vapor laser lock in atomic rubidium.

    PubMed

    McCarron, Daniel J; Hughes, Ifan G; Tierney, Patrick; Cornish, Simon L

    2007-09-01

    The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D(2) transitions in atomic rubidium is described. A 5 cm long vapor cell is placed in a double-solenoid arrangement to produce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field and cell temperature. For the weaker transitions both the amplitude and gradient of the signal are increased by an order of magnitude.

  2. Very Long Single and Few-Walled Boron Nitride Nanotubes via the Pressurized Vapor/Condenser Method

    NASA Technical Reports Server (NTRS)

    Smith, Michael W.; Jordan, Kevin C.; Park, Cheol; Kim, Jae-Woo; Lillehei, Peter T.; Crooks, Roy; Harrison, Joycelyn S.

    2009-01-01

    A new method for producing long, small diameter, single and few-walled, boron nitride nanotubes (BNNTs) in macroscopic quantities is reported. The pressurized vapor/condenser (PVC) method produces, without catalysts, highly crystalline, very long, small diameter, BNNTs. Palm-sized, cotton-like masses of BNNT raw material were grown by this technique and spun directly into centimeters-long yarn. Nanotube lengths were observed to be 100 times that of those grown by the most closely related method. Self-assembly and growth models for these long BNNTs are discussed.

  3. Estimated vapor pressure for WTP process streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pike, J.; Poirier, M.

    Design assumptions during the vacuum refill phase of the Pulsed Jet Mixers (PJMs) in the Hanford Waste Treatment and Immobilization Plant (WTP) equate the vapor pressure of all process streams to that of water when calculating the temperature at which the vacuum refill is reduced or eliminated. WTP design authority asked the authors to assess this assumption by performing calculations on proposed feed slurries to calculate the vapor pressure as a function of temperature. The vapor pressure was estimated for each WTP waste group. The vapor pressure suppression caused by dissolved solids is much greater than the increase caused bymore » organic components such that the vapor pressure for all of the waste group compositions is less than that of pure water. The vapor pressure for each group at 145°F ranges from 81% to 98% of the vapor pressure of water. If desired, the PJM could be operated at higher temperatures for waste groups with high dissolved solids that suppress vapor pressure. The SO4 group with the highest vapor pressure suppression could be operated up to 153°F before reaching the same vapor pressure of water at 145°F. However, most groups would reach equivalent vapor pressure at 147 to 148°F. If any of these waste streams are diluted, the vapor pressure can exceed the vapor pressure of water at mass dilution ratios greater than 10, but the overall effect is less than 0.5%.« less

  4. Microsurgical Bypass Training Rat Model: Part 2-Anastomosis Configurations.

    PubMed

    Tayebi Meybodi, Ali; Lawton, Michael T; Yousef, Sonia; Mokhtari, Pooneh; Gandhi, Sirin; Benet, Arnau

    2017-11-01

    Mastery of microsurgical anastomosis is key to achieving good outcomes in cerebrovascular bypass procedures. Animal models (especially rodents) provide an optimal preclinical bypass training platform. However, the existing models for practicing different anastomosis configurations have several limitations. We sought to optimize the use of the rat's abdominal aorta and common iliac arteries (CIA) for practicing the 3 main anastomosis configurations commonly used in cerebrovascular surgery. Thirteen male Sprague-Dawley rats underwent inhalant anesthesia. The abdominal aorta and the CIAs were exposed. The distances between the major branches of the aorta were measured to find the optimal location for an end-to-end anastomosis. Also, the feasibility of performing side-to-side and end-to-side anastomoses between the CIAs was assessed. All bypass configurations could be performed between the left renal artery and the CIA bifurcation. The longest segments of the aorta without major branches were 1) between the left renal and left iliolumbar arteries (16.9 mm ± 4.6), and 2) between the right iliolumbar artery and the aortic bifurcation (9.7 mm ± 4.7). The CIAs could be juxtaposed for an average length of 7.6 mm ± 1.3, for a side-to-side anastomosis. The left CIA could be successfully reimplanted on to the right CIA at an average distance of 9.1 mm ± 1.6 from the aortic bifurcation. Our results show that rat's abdominal aorta and CIAs may be effectively used for all the anastomosis configurations used in cerebral revascularization procedures. We also provide technical nuances and anatomic descriptions to plan for practicing each bypass configuration. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Molecular Self-Assembly of Group 11 Pyrazolate Complexes as Phosphorescent Chemosensors for Detection of Benzene

    NASA Astrophysics Data System (ADS)

    Ghazalli, N. F.; Yuliati, L.; Lintang, H. O.

    2018-01-01

    We highlight the systematic study on vapochromic sensing of aromatic vapors such as benzene using phosphorescent trinuclear pyrazolate complexes (2) with supramolecular assembly of a weak intermolecular metal-metal interaction consisting of 4-(3,5-dimethoxybenzyl)-3,5-dimethyl pyrazole ligand (1) and group 11 metal ions (Cu(I), Ag(I), Au(I)). The resulting chemosensor 2(Cu) revealed positive response to benzene vapors in 5 mins by blue-shifting its emission band in 44 nm (from 616 to 572 nm) and emitted bright orange to green, where this change cannot be recovered even with external stimuli. Comparing to 2(Ag) with longer metal-metal distance (473 nm) with same sensing time and quenching in 37%, 2(Au) gave quenching in 81% from its original intensity at 612 nm with reusability in 82% without external stimuli and emitted less emissive of red-orange from its original color. The shifting phenomenon in 2(Cu) suggests diffusion of benzene vapors to inside molecules for formation of intermolecular interaction with Cu(I)-Cu(I) interaction while quenching phenomenon in 2(Au) suggests diffusion of benzene vapors to between the Au(I)-Au(I) interaction. These results indicate that suitable molecular structure of ligand and metal ion in pyrazolate complex is important for designing chemosensor in the detection of benzene vapors.

  6. Process for recovering organic vapors from air

    DOEpatents

    Baker, Richard W.

    1985-01-01

    A process for recovering and concentrating organic vapor from a feed stream of air having an organic vapor content of no more than 20,000 ppm by volume. A thin semipermeable membrane is provided which has a feed side and a permeate side, a selectivity for organic vapor over air of at least 50, as measured by the ratio of organic vapor permeability to nitrogen permeability, and a permeability of organic vapor of at least 3.times.10.sup.-7 cm.sup.3 (STP) cm/cm.sup.2 sec.cm Hg. The feed stream is passed across the feed side of the thin semipermeable membrane while providing a pressure on the permeate side which is lower than the feed side by creating a partial vacuum on the permeate side so that organic vapor passes preferentially through the membrane to form an organic vapor depleted air stream on the feed side and an organic vapor enriched stream on the permeate side. The organic vapor which has passed through the membrane is compressed and condensed to recover the vapor as a liquid.

  7. Occipital Artery to Middle Cerebral Artery Bypass in Cases of Unavailable Superficial Temporal Artery.

    PubMed

    Hirano, Tsukasa; Mikami, Takeshi; Suzuki, Hime; Hirano, Toru; Kimura, Yusuke; Komatsu, Katusya; Akiyama, Yukinori; Wanibuchi, Masahiko; Mikuni, Nobuhiro

    2018-04-01

    In neurosurgery, extracranial-to-intracranial (EC-IC) bypass surgery is necessary for patients who have undergone surgery in which the superficial temporal artery (STA) was already used for a different bypass procedure or was damaged. Here we report our experience with EC-IC bypass using the occipital artery (OA) in patients in whom the STA was unavailable, and discuss the technical considerations and pitfalls. Five patients with ischemic-onset moyamoya disease and atherosclerotic disease were included. Two patterns of skin incisions were planned according to the OA pathway and recipient artery location. In one of these methods, a skin incision is made above the OA, and a craniotomy is performed under this incision after OA dissection. In the other method, a skin incision is made above the OA to enable its dissection, and a craniotomy is performed via a separate skin incision. No major perioperative complications developed in any of the 5 cases, and bypass patency was confirmed in all patients. There was a significant difference between the preoperative and postoperative asymmetry ratios of the mean transit time values. Our findings suggest that OA-to-middle cerebral artery (MCA) bypass is a simple and effective technique in patients in whom the STA was already used or was damaged by previous intracranial revascularization or craniotomy. This procedure could be an alternative to STA-MCA bypass in patients without an available STA. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. An unusual cause of ischemia after coronary bypass grafting!!

    PubMed

    Hammami, Rania; Charfeddine, Salma; Elleuch, Nizar; Fourati, Hela; Abid, Leila; Kammoun, Samir

    2018-01-01

    Coronary subclavian steal syndrome is an uncommon cause of ischemia recurrence after coronary artery bypass grafting. Endovascular treatment of subclavian artery stenosis or occlusion is increasingly common and appears to offer a safe and effective alternative to surgical revascularization. We report a case of recurrent angina after coronary artery bypass grafting for critical subclavian artery stenosis. The anomalous origin of the vertebral artery from the aortic arch was an indication for endovascular treatment. We discuss the diagnostic difficulties and the management pitfalls of subclavian artery angioplasty in this syndrome. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Single center experience of aortic bypass graft for aortic arch obstruction in children.

    PubMed

    Shinkawa, Takeshi; Chipman, Carl; Holloway, Jessica; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki

    2017-01-01

    The purpose of this study is to access the outcomes of aortic bypass graft placement in children. This is a retrospective review of all children having aortic bypass graft placement for aortic arch obstruction for the first time between 1982 and 2013 at a single institution. The actuarial survival and the freedom from aortic arch reoperation were calculated and compared between the groups. Seventy consecutive children underwent aortic bypass graft placements. The median age and body weight at the operation were 14 days and 3.6 kg. There were 7 early deaths, 6 late deaths, and 7 heart transplants during the median follow-up of 10.8 years (0.0-31.5 years). The actuarial transplant free survival was 64.7 % at 20 years and the freedom from aortic arch reoperation was 50.5 % at 10 years. Between the children younger than 1 year old and older than 1 year old, there were significant differences in actuarial transplant free survival (56.4 vs. 100 % at 15 years, p = 0.0042) and in the freedom from aortic arch reoperation (18.7 vs. 100 % at 10 years, p < 0.001). The children who received aortic bypass graft larger than 16 mm in size had no aortic arch reoperation at 15 years. The aortic bypass graft placement for aortic arch obstruction can be done with low mortality and morbidity for children who can receive bypass graft larger than 16 mm in size. However, it should be avoided for the neonates and infants except selected situations.

  10. Receptivity and Bypass Dynamics

    NASA Technical Reports Server (NTRS)

    Lasseigne, D. G.; Criminale, W. O.; Joslin, R. D.; Jackson, T. L.

    1999-01-01

    Problems concerning laminar-turbulent transition are addressed by solving a series of initial value problems. Solutions to the temporal, initial-value problem .with an inhomogeneous forcing term imposed upon the flow are sought. It is shown that: (1) A transient disturbance lying located outside of the boundary layer can lead to the growth of an unstable Tollmein-Schlicting wave; (2) A resonance with the continuous spectrum may provide a mechanism for bypass transition; and (3) The continuum modes of a disturbance feed directly into the Tollmein-Schlicting wave downstream through non-parallel effects.

  11. An animal model for instructing and the study of in situ arterial bypass.

    PubMed

    Saifi, J; Chang, B B; Paty, P S; Kaufman, J; Leather, R P; Shah, D M

    1990-11-01

    A canine model that used the cephalic vein to bypass from the brachial to the ulnar artery was designed for use in instructing and evaluating surgical technique needed for constructing an in situ arterial bypass. This model was used for instructing vascular residents in the in situ vein bypass technique. The use of this model enabled the resident to become more adept with the instruments for valve incision and construction of small vessel anastomosis. The improvement in the resident's operative technique was reflected by a decrease in the number of technical complications (missed valves, missed arteriovenous fistulas, poorly constructed anastomoses) and improved patency rate.

  12. [Results of using composite bypass grafts with infragenicular distal anastomosis].

    PubMed

    Pokrovskiĭ, A V; Iakhontov, D I

    2014-01-01

    The authors share herein their experience with composite bypass grafts and PTFE synthetic prostheses used for treatment of obliterating diseases of the infrainguinal-segment arteries. The data of the study were based on the outcomes obtained in 92 patients. The authors assessed the condition of the outflow pathways and their effect on patency of composite bypass grafts in the immediate and remote postoperative periods, followed by comparative analysis of the short- and long-term therapeutic outcomes after using composite bypass grafts and PTFE synthetic prostheses in the infragenicular position for femoropopliteal and femorotibial reconstructions, also assessing the effect of the localization of the distal anastomosis on the immediate and remote therapeutic outcomes. Based on the obtained findings it was determined that the immediate results of patency depended upon the state of the outflow pathways and localization of the distal anastomosis. Thus, by the 1st, 3rd and 5th year of follow up patency of transplants in patients with the runoff score less than 7.0 amounted to 78.3, 21.7 and 4.3%, respectively. Analogous indices of patency in patients with the runoff score equalling or greater than 7.0 amounted to 60.7 and 3.6% for the 1st and 3rd year, respectively. The remote results of patency turned out to depend on the type of a vascular transplant and the state of the outflow pathways and did not depend on the localization of the distal anastomosis. Thus, the remote results of patency for the composite bypass graft for the 1st, 3rd and 5th year of follow up amounted to 74.5, 19.6 and 5.9%, respectively, versus 60.8 and 8.6% by the first and third year for the PTFE prosthesis. The limb salvage rate at the same terms for the composite bypass graft amounted to 94.1, 84.3 and 78.4% versus 73.9, 56.5 and 52.2% for the PTFE prosthesis.

  13. Bypassing Intestinal Sugar Enhancement of Sweet Appetite.

    PubMed

    Sclafani, Anthony

    2016-01-12

    Intestinal sugar sensing has an appetite-stimulating action that enhances preferences for sweets. Han et al. (2016) report that duodenal-jejunal bypass surgery reduces sweet appetite by reducing sugar-induced dopamine release in the dorsal striatum. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Postoperative Hydrocortisone Infusion Reduces the Prevalence of Low Cardiac Output Syndrome After Neonatal Cardiopulmonary Bypass.

    PubMed

    Robert, Stephen M; Borasino, Santiago; Dabal, Robert J; Cleveland, David C; Hock, Kristal M; Alten, Jeffrey A

    2015-09-01

    Neonatal cardiac surgery with cardiopulmonary bypass is often complicated by morbidity associated with inflammation and low cardiac output syndrome. Hydrocortisone "stress dosing" is reported to provide hemodynamic benefits in some patients with refractory shock. Development of cardiopulmonary bypass-induced adrenal insufficiency may provide further rationale for postoperative hydrocortisone administration. We sought to determine whether prophylactic, postoperative hydrocortisone infusion could decrease prevalence of low cardiac output syndrome after neonatal cardiac surgery with cardiopulmonary bypass. Double-blind, randomized control trial. Pediatric cardiac ICU and operating room in tertiary care center. Forty neonates undergoing cardiac surgery with cardiopulmonary bypass were randomized (19 hydrocortisone and 21 placebo). Demographics and known risk factors were similar between groups. After cardiopulmonary bypass separation, bolus hydrocortisone (50 mg/m²) or placebo was administered, followed by continuous hydrocortisone infusion (50 mg/m²/d) or placebo tapered over 5 days. Adrenocorticotropic hormone stimulation testing (1 μg) was performed before and after cardiopulmonary bypass, prior to steroid administration. Blood was collected for cytokine analysis before and after cardiopulmonary bypass. Subjects receiving hydrocortisone were less likely to develop low cardiac output syndrome (5/19, 26% vs 12/21, 57%; p = 0.049). Hydrocortisone group had more negative net fluid balance at 48 hours (-114 vs -64 mL/kg; p = 0.01) and greater urine output at 0-24 hours (2.7 vs 1.2 mL/kg/hr; p = 0.03). Hydrocortisone group weaned off catecholamines and vasopressin sooner than placebo, with a difference in inotrope-free subjects apparent after 48 hours (p = 0.033). Five placebo subjects (24%) compared with no hydrocortisone subjects required rescue steroids (p = 0.02). Thirteen (32.5%) had adrenal insufficiency after cardiopulmonary bypass. Patients with adrenal

  15. Closed-chest cardiopulmonary bypass and cardioplegia: basis for less invasive cardiac surgery.

    PubMed

    Peters, W S; Siegel, L C; Stevens, J H; St Goar, F G; Pompili, M F; Burdon, T A

    1997-06-01

    We developed a method of closed-chest cardiopulmonary bypass to arrest and protect the heart with cardioplegic solution. This method was used in 54 dogs and the results were retrospectively analyzed. Bypass cannulas were placed in the right femoral vessels. A balloon occlusion catheter was passed via the left femoral artery and positioned in the ascending aorta. A pulmonary artery vent was placed via the jugular vein. In 17 of the dogs retrograde cardioplegia was provided with a percutaneous coronary sinus catheter. Cardiopulmonary bypass time was 111 +/- 27 minutes (mean +/- standard deviation) and cardiac arrest time was 66 +/- 21 minutes. Preoperative cardiac outputs were 2.9 +/- 0.70 L/min and postoperative outputs were 2.9 +/- 0.65 L/min (p = not significant). Twenty-one-French and 23F femoral arterial cannulas that allowed coaxial placement of the ascending aortic balloon catheter were tested in 3 male calves. Line pressures were higher, but not clinically limiting, with the balloon catheter placed coaxially. Adequate cardiopulmonary bypass and cardioplegia can be achieved in the dog without opening the chest, facilitating less invasive cardiac operations. A human clinical trial is in progress.

  16. BioVapor Model Evaluation

    EPA Science Inventory

    General background on modeling and specifics of modeling vapor intrusion are given. Three classical model applications are described and related to the problem of petroleum vapor intrusion. These indicate the need for model calibration and uncertainty analysis. Evaluation of Bi...

  17. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    PubMed

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    Single-segment saphenous vein remains the optimal conduit for infrainguinal revascularization. In its absence, prosthetic conduit may be used. Existing data regarding the significance of anastomotic distal vein adjunct (DVA) usage with prosthetic grafts are based on small series. This is a retrospective cohort analysis derived from the regional Vascular Study Group of New England as well as the Brigham and Women's hospital database. A total of 1018 infrainguinal prosthetic bypass grafts were captured in the dataset from 73 surgeons at 15 participating institutions. Propensity scoring and 3:1 matching was performed to create similar exposure groups for analysis. Outcome measures of interest included: primary patency, freedom from major adverse limb events (MALEs), and amputation free survival at 1 year as a function of vein patch utilization. Time to event data were compared with the log-rank test; multivariable Cox proportional hazard models were used to evaluate the adjusted association between vein cuff usage and the primary end points. DVA was defined as a vein patch, cuff, or boot in any configuration. Of the 1018 bypass operations, 94 (9.2%) had a DVA whereas 924 (90.8%) did not (no DVA). After propensity score matching, 88 DVAs (25%) and 264 no DVAs (75%) were analyzed. On univariate analysis of the matched cohort, the DVA and no DVA groups were similar in terms of mean age (70.0 vs 69.0; P = .55), male sex (58.0% vs 58.3%; P > .99), and preoperative characteristics such as living at home (93.2% vs 94.3%; P = .79) and independent ambulatory status (72.7% vs 75.7%; P = .64). The DVA and no DVA groups had similar rates of major comorbidities such as hypertension chronic obstructive pulmonary disease, diabetes mellitus, coronary artery disease, and dialysis dependence (P > .05 for all). Likewise, they had similar rates of distal origin grafts (13.6% vs 12.5%; P = .85), critical limb ischemia indications (P = .53), and prior arterial bypass (58% vs 47%; P = .08

  18. Effects of solvent evaporation conditions on solvent vapor annealed cylinder-forming block polymer thin films

    NASA Astrophysics Data System (ADS)

    Grant, Meagan; Jakubowski, William; Nelson, Gunnar; Drapes, Chloe; Baruth, A.

    Solvent vapor annealing is a less time and energy intensive method compared to thermal annealing, to direct the self-assembly of block polymer thin films. Periodic nanostructures have applications in ultrafiltration, magnetic arrays, or other structures with nanometer dimensions, driving its continued interest. Our goal is to create thin films with hexagonally packed, perpendicular aligned cylinders of poly(lactide) in a poly(styrene) matrix that span the thickness of the film with low anneal times and low defect densities, all with high reproducibility, where the latter is paramount. Through the use of our computer-controlled, pneumatically-actuated, purpose-built solvent vapor annealing chamber, we have the ability to monitor and control vapor pressure, solvent concentration within the film, and solvent evaporation rate with unprecedented precision and reliability. Focusing on evaporation, we report on two previously unexplored areas, chamber pressure during solvent evaporation and the flow rate of purging gas aiding the evaporation. We will report our exhaustive results following atomic force microscopy analysis of films exposed to a wide range of pressures and flow rates. Reliably achieving well-ordered films, while occurring within a large section of this parameter space, was correlated with high-flow evaporation rates and low chamber pressures. These results have significant implications on other methods of solvent annealing, including ``jar'' techniques.

  19. Roux-en Y gastric bypass is superior to duodeno-jejunal bypass in improving glycaemic control in Zucker diabetic fatty rats.

    PubMed

    Seyfried, Florian; Bueter, Marco; Spliethoff, Kerstin; Miras, Alexander D; Abegg, Kathrin; Lutz, Thomas A; le Roux, Carel W

    2014-11-01

    Whilst weight loss results in many beneficial metabolic consequences, the immediate improvement in glycaemia after Roux-en-Y Gastric bypass (RYGB) remains intriguing. Duodenal jejunal bypass (DJB) induces similar glycaemic effects, while not affecting calorie intake or weight loss. We studied diabetic ZDF(fa/fa) rats to compare the effects of DJB and RYGB operations on glycaemia. Male ZDF(fa/fa) rats, aged 12 weeks underwent RYGB, DJB or sham operations. Unoperated ZDF(fa/fa) and ZDF(fa/+w)ere used as controls. Body weight, food intake, fasting glucose, insulin and gut hormones were measured at baseline and on postoperative days 2, 10 and 35. An oral glucose tolerance test (OGTT) was performed on days 12 and 26. DJB had similar food intake and body weight to sham-operated and unoperated control ZDF(fa/fa) rats (p = NS), but had lower fasting glucose (p < 0.05). RYGB had lower food intake, body weight and fasting glucose compared to all groups (p < 0.001). DJB prevented the progressive decline in fasting insulin observed in the sham-operated or unoperated ZDF(fa/fa) rats, while RYGB with normalized glycaemia reduced the physiological requirement for raised fasting insulin. Bypassing the proximal small bowel with the DJB has mild to moderate body weight independent effects on glucose homeostasis and preservation of fasting insulin levels in the medium term. These effects might be further amplified by the additional anatomical and physiological changes after RYGB.

  20. Timing of pregnancy after gastric bypass-a national register-based cohort study.

    PubMed

    Kjær, Mette Mandrup; Nilas, Lisbeth

    2013-08-01

    Current recommendations suggest postponing pregnancy by at least 1 year after gastric bypass. During the first postoperative year, women are in a catabolic phase with a rapid weight loss which may increase the risk of adverse pregnancy and neonatal outcomes. This study tested the hypothesis that the risk of adverse pregnancy and neonatal outcomes is increased in women who conceive during the first year after gastric bypass surgery. This is a national register-based cohort study covering all Danish deliveries during 2004-2010 in women with prior Roux-en-Y gastric bypass surgery. Only the first postoperative birth was included. The risk of adverse pregnancy and neonatal outcomes was compared between women who conceived within the first postoperative year and women who conceived later. Data were extracted from the Danish National Patient Registry and The Danish Medical Birth Register. Of 286 women who had a singleton delivery after Roux-en-Y gastric bypass surgery, 158 women conceived within the first year and 128 later. There was no statistically significant difference (p > 0.05) between the two groups regarding neonatal birth weight, gestational age, risk of preeclampsia, gestational diabetes mellitus, labor induction, cesarean section, postpartum hemorrhage (>500 ml), preterm birth (before 37 weeks), small for gestational age, large for gestational age, or Apgar score (5 min ) below 7, or in the need of neonatal intensive care. This study showed no evidence to support a recommendation to delay pregnancy until after the first postoperative year. At present, the optimal time for pregnancy after gastric bypass is unknown.

  1. Temperature monitoring during cardiopulmonary bypass--do we undercool or overheat the brain?

    PubMed

    Kaukuntla, Hemanth; Harrington, Deborah; Bilkoo, Inderaj; Clutton-Brock, Tom; Jones, Timothy; Bonser, Robert S

    2004-09-01

    Brain cooling is an essential component of aortic surgery requiring circulatory arrest and inadequate cooling may lead to brain injury. Similarly, brain hyperthermia during the rewarming phase of cardiopulmonary bypass may also lead to neurological injury. Conventional temperature monitoring sites may not reflect the core brain temperature (Tdegrees). We compared jugular bulb venous temperatures (JB) during deep hypothermic circulatory arrest and normothermic bypass with Nasopharyngeal (NP), Arterial inflow (AI), Oesophageal (O), Venous return (VR), Bladder (B) and Orbital skin (OS) temperatures. 18 patients undergoing deep hypothermia (DH) and 8 patients undergoing normothermic bypass (mean bladder Tdegrees-36.29 degreesC) were studied. For DH, cooling was continued to 15 degreesC NP (mean cooling time-66 min). At pre-determined arterial inflow Tdegrees, NP, JB and O Tdegree's were measured. A 6-channel recorder continuously recorded all Tdegree's using calibrated thermocouples. During the cooling phase of DH, NP lagged behind AI and JB Tdegree's. All these equilibrated at 15 degreesC. During rewarming, JB and NP lagged behind AI and JB was higher than NP at any time point. During normothermic bypass, although NP was reflective of the AI and JB Tdegrees trends, it underestimated peak JB Tdegrees (P=0.001). Towards the end of bypass, peak JB was greater than the arterial inflow Tdegrees (P=0.023). If brain venous outflow Tdegrees (JB) accurately reflects brain Tdegrees, NP Tdegrees is a safe surrogate indicator of cooling. During rewarming, all peripheral sites underestimate brain temperature and caution is required to avoid hyperthermic arterial inflow, which may inadvertently, result in brain hyperthermia.

  2. Bleeding duodenal ulcer after Roux-en-Y gastric bypass surgery: the value of laparoscopic gastroduodenoscopy.

    PubMed

    Issa, Hussain; Al-Saif, Osama; Al-Momen, Sami; Bseiso, Bahaa; Al-Salem, Ahmed

    2010-01-01

    Roux-en-Y gastric bypass is a common surgical procedure used to treat patients with morbid obesity. One of the rare, but potentially fatal complications of gastric bypass is upper gastrointestinal bleeding, which can pose diagnostic and therapeutic dilemmas. This report describes a 39-year-old male with morbid obesity who underwent a Roux-en-Y gastric bypass. Three months postoperatively, he sustained repeated and severe upper attacks of upper gastrointestinal bleeding. He received multiple blood transfusions, and had repeated upper and lower endoscopies with no diagnostic yield. Finally, he underwent laparoscopic endoscopy which revealed a bleeding duodenal ulcer. About 5 ml of saline with adrenaline was injected, followed by electrocoagulation to seal the overlying cleft and blood vessel. He was also treated with a course of a proton pump inhibitor and given treatment for H pylori eradication with no further attacks of bleeding. Taking in consideration the difficulties in accessing the bypassed stomach endoscopically, laparoscopic endoscopy is a feasible and valuable diagnostic and therapeutic procedure in patients who had gastric bypass.

  3. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    NASA Technical Reports Server (NTRS)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  4. Vapor-barrier Vacuum Isolation System

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M. (Inventor); Taminger, Karen M. (Inventor)

    2014-01-01

    A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

  5. A randomized trial of the topical effect of antifibrinolytic epsilon aminocaproic Acid on coronary artery bypass surgery without cardiopulmonary bypass.

    PubMed

    Gurian, Danilo Bortolotto; Meneghini, Adriano; Abreu, Luiz Carlos de; Murad, Neif; Matos, Leandro Luongo de; Pires, Adilson Casemiro; Valenti, Vitor E; Breda, João Roberto

    2014-09-01

    We assessed the effect of the topical application of epsilon-aminocaproic antifibrinolytic acid (EACA) on the pericardium of patients submitted to coronary artery bypass graft (CABG) without the use of cardiopulmonary bypass (CPB). This is a prospective, randomized, and double-blind study. We evaluated 26 patients with chronic coronary heart disease indicated for CABG without CPB (EACA and placebo groups). The analysis of the postoperative hematological results showed no difference between groups in hemoglobin and hematocrit. There was no difference between the groups regarding the postoperative bleeding through the drains in the first 24 hours, 48 hours, and accumulated loss until removal of drains. The use of EACA in patients undergoing CABG without CPB presented no difference in the reduction of the amount of bleeding and the need for blood transfusions. © The Author(s) 2013.

  6. The experience of totally endoscopic coronary bypass grafting with the robotic system «Da Vinci» in Russia

    NASA Astrophysics Data System (ADS)

    Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.

    2015-11-01

    A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.

  7. A Simple Experiment for Determining Vapor Pressure and Enthalpy of Vaporization of Water.

    ERIC Educational Resources Information Center

    Levinson, Gerald S.

    1982-01-01

    Laboratory procedures, calculations, and sample results are described for a freshman chemistry experiment in which the Clausius-Clapeyron equation is introduced as a means of describing the variation of vapor pressure with temperature and for determining enthalpy of vaporization. (Author/SK)

  8. The effect of extracorporeal life support on the brain: cardiopulmonary bypass.

    PubMed

    Jonas, Richard A

    2005-02-01

    This article reviews the mechanisms of brain injury associated with cardiopulmonary bypass. These include embolic injury of both a gaseous and particulate nature as well as global hypoxic ischemic injury. Ischemic injury can result from problems associated with venous drainage or with arterial inflow including a steal secondary to systemic to pulmonary collateral vessels. Modifications in the technique of cardiopulmonary bypass have reduced the risk of global hypoxic/ischemic injury. Laboratory and clinical studies have demonstrated that perfusion hematocrit should be maintained above 25% and preferably above 30%. Perfusion pH is also critically important, particularly when hypothermia is employed. An alkaline pH can limit cerebral oxygen delivery by inducing cerebral vasoconstriction as well as shifting oxyhemoglobin dissociation leftwards. If deep hypothermia is employed, it is critically important to add carbon dioxide using the so-called "pH stat" strategy. Oxygen management during cardiopulmonary bypass is also important. Although there is currently enthusiasm for using air rather than pure oxygen, ie, adding nitrogen, this does introduce a greater risk of gaseous nitrogen emboli since nitrogen is much less soluble than oxygen. The use of pure oxygen in conjunction with CO2 to apply the pH stat strategy is recommended. Many of the lessons learned from studies focusing on brain protection during cardiopulmonary bypass can be applied to the patient being supported with extracorporeal membrane oxygenation.

  9. Re-birth after coronary bypass graft surgery: a hermeneutic-phenomenological study.

    PubMed

    Abbasi, Mohammad; Mohammadi, Nooredin; Nasrabadi, Alireza Nikbakht; Fuh, Suh Boudouin; Sadeghi, Tahereh

    2014-03-31

    Although coronary artery bypass graft surgery has significant effects on reducing the symptoms of coronary artery disease, there is not enough knowledge and understanding of lived experience of patients after surgery. Understanding lived experience of this group of patients would be helpful for healthcare staff to provide better services to the patients. The aim of this study was to describe with a deeper understanding, the lived experiences of patients after Coronary Artery Bypass Graft Surgery. Using a hermeneutic phenomenological approach and a Van-Manen analysis method, in-depth semi-structured interviews were conducted with eleven participants who had lived experienced of at least six months post - coronary artery bypass graft surgery. Re-birth was the main theme that emerged in the process of data analysis. This theme was derived from four sub-themes including "feels younger", ''vigorous heart'', ''intrepid life'' and ''oriented to be healthy''. Life after a coronary artery bypass graft surgery is often appreciated as a re-birth by persons with these experiences as surgery did not only provide a feeling of wellness, but also added a sensation of youthfulness and improvement in the quality of life for these participants. In addition, they would actively participate in health promotional activities such as; adherence to medication and diet regimes, changes in lifestyle to maintain their health.

  10. Triiodothyronine supplementation and cytokines during cardiopulmonary bypass in infants and children

    PubMed Central

    Priest, James R.; Slee, April; Olson, Aaron K.; Ledee, Dolena; Morrish, Fionnuala; Portman, Michael A.

    2016-01-01

    Objective The Triiodothyronine Supplementation in Infants and Children Undergoing Cardiopulmonary Bypass (TRICC) study demonstrated a shortened time to extubation in children younger than 5 months old undergoing cardiopulmonary bypass for congenital heart surgery with triiodothyronine supplementation. Cardiopulmonary bypass precipitates a systemic inflammatory response that affects recovery, and triiodothyronine is related to cytokine mediators of inflammation. We sought to investigate the preoperative cytokine levels by age and relationship to the triiodothyronine levels and to examine the effect of the cytokine levels on the time to extubation. Methods We measured 6 cytokines at preoperative time 0 and 6 and 24 hours after crossclamp removal in 76 subjects. Results The preoperative cytokine levels were related to both the triiodothyronine levels and the patient age. The postoperative cytokine levels were predictive of the triiodothyronine levels at 6, 12, 24, and 72 hours. Preoperative CCL4 was associated with an increased chance of early extubation. Inclusion of the cytokines did not change the relationship of triiodothyronine to the time to extubation, and the postoperative course of interleukin-6 was independently associated with a decreased chance of early extubation. Conclusions The preoperative and postoperative cytokine levels, in particular, interleukin-1β, showed complex time-dependent relationships with triiodothyronine. The data suggest that cytokine-mediated suppression of triiodothyronine plays an important role in determining the clinical outcome after cardiopulmonary bypass. PMID:22743177

  11. Use of Negative Pressure Wound Therapy for Lower Limb Bypass Incisions.

    PubMed

    Tan, Kah Wei; Lo, Zhiwen Joseph; Hong, Qiantai; Narayanan, Sriram; Tan, Glenn Wei Leong; Chandrasekar, Sadhana

    2017-12-25

    Objective : The use of negative pressure wound therapy (NPWT) for post-surgical cardiothoracic, orthopedic, plastic, and obstetric and gynecologic procedures has been described. However, there are no data regarding its use for lower limb bypass incisions. We aimed to investigate the outcomes of NPWT in preventing surgical site infection (SSI) in patients with lower limb arterial bypass incisions. Materials and Methods : We retrospectively used data of 42 patients who underwent lower limb arterial bypass with reversed great saphenous vein between March 2014 and June 2016 and compared conventional wound therapy and NPWT with regard to preventing SSI. Results : Twenty-eight (67%) patients underwent conventional wound therapy and 14 (33%) underwent NPWT. There were no statistical differences regarding patient characteristics and mean SSI risk scores between the two patient groups (13.7% for conventional wound therapy vs. 13.4% for NPWT; P=0.831). In the conventional group, nine instances of SSI (32%) and three (11%) of these required subsequent surgical wound debridement, whereas in the NPWT group, there was no SSI incidence (P=0.019). Secondary outcomes such as the length of hospital stay, 30-day readmission rate, and need for secondary vascular procedures were not statistically different between the two groups. Conclusion : The use of NPWT for lower limb arterial bypass incisions is superior to that of conventional wound therapy because it may prevent SSIs.

  12. Perceived learning needs of Syrian patients postcoronary artery bypass graft surgery.

    PubMed

    Omari, Ferdous; Al-Zaru, Ibtisam; Al-Yousef, Rasha H

    2014-06-01

    To describe the perceived learning needs of Syrian patients who underwent coronary artery bypass graft surgery before hospital discharge and to examine the differences in the mean scores of the categories (subscales) of the modified Cardiac Patients Learning Needs Inventory according to the demographic characteristics of the participants. Knowledge about the learning needs of patients who underwent coronary artery bypass graft surgery can help nurses in coronary care units to provide them with the information that they need. This might improve their quality of life through decreasing complications, length of stay in the hospital and hospital readmissions. A descriptive design was used for this study. A convenience sample of 135 patients participated in this study and completed the demographic form and the modified Cardiac Patients Learning Needs Inventory. Information about chest and leg wound care, complications, medication and physical activity was the most important learning needs. There were significant differences between patients' perceptions of learning needs and their age, chronic illnesses and their working status. Syrian patients who underwent coronary artery bypass graft surgery were able to identify their learning needs that should be the focus of nursing practice. Meeting the needs of patients who underwent coronary artery bypass graft surgery should be emphasised in nursing practice. Meeting these needs might enhance their self-care behaviours. © 2013 John Wiley & Sons Ltd.

  13. Effects of bolt-hole contact on bearing-bypass damage-onset strength

    NASA Technical Reports Server (NTRS)

    Crews, John H., Jr.; Naik, Rajiv A.

    1991-01-01

    A combined experimental and analytical study was conducted to investigate the effects of bolt-hole contact on the bearing bypass strength of a graphite-epoxy laminate. Tests were conducted on specimens consisting of 16-ply quasi-isotropic T300/5208 laminates with a centrally located hole. Bearing loads were applied through a clearance-fit steel bolt. Damage onset strength and damage mode were determined for each test case. A finite element procedure was used to calculate the bolt-hole stresses and bolt contact for each test case. A finite element procedure was used to calculate the bolt-hole stresses and bolt contact for each measured damage-onset strength. For the tension bearing-bypass cases tested, the bolt contact half-angle was approximately 60 degrees at damage onset. For compression, the contact angle was 20 degrees as the bypass load increased. A corresponding decrease in the bearing damage onset strength was attributed to the decrease in contact angle which made the bearing loads more severe. Hole boundary stresses were also computed by superimposing stresses for separate bearing and bypass loading. Stresses at the specimen net section were accurately approximated by the superposition procedure. However, the peak bearing stresses had large errors because the bolt contact angles were not represented correctly. For compression, peak bearing stress errors of nearly 50 percent were calculated.

  14. A compact centrifugal pump for cardiopulmonary bypass.

    PubMed

    Sasaki, T; Jikuya, T; Aizawa, T; Shiono, M; Sakuma, I; Takatani, S; Glueck, J; Noon, G P; Nosé, Y; DeBakey, M E

    1992-12-01

    A majority of the cardiopulmonary bypass (CPB) systems still utilize bulky roller pumps. A direct-drive small centrifugal pump intended for second-generation CPB pump has been developed. The pump has a 50 mm diameter impeller and provides a 6 L/min flow at 3,000 rpm against 300 mm Hg. A flexible drive shaft allows us to separate the pump head from the console resulting in easier manipulation. An in vitro study showed that the pump generated less hemolysis (index of hemolysis = 0.0011, comparable to the value for Bio-medicus BP-80). To improve blood flow around the shaft-seal region and to reduce thrombus formation around the shaft, six holes were drilled through the impeller. In biventricular bypass experiments using calves, our pump demonstrated excellent antithrombogenicity and durability for 48 h. And the compact and atraumatic centrifugal pump system showed excellent performance and easy manipulation under actual CPB conditions in animal.

  15. Gradual Hunterian ligation for infected prosthetic bypass.

    PubMed

    Egun, A; Slade, D; McCollum, C N

    2000-04-01

    To review gradual snare occlusion for the management of complex or recurrent graft infection. Medical records of patients treated with gradual snare occlusion following graft infection were reviewed for indication for operation, type of bypass and graft material used. In addition, infecting organism, grade of infection (Szilágyi) and outcome were recorded. Four femoropopliteal, two extra-anatomic (axillofemoral) and aortobifemoral bypasses were included in this study. All had chronic infection (Szilágyi grade III) with onset of 4 to 24 months and two of which were recurrent. The causative organisms were coagulase-negative staphylococci, Staphylococcus epidermidis and methicillin-resistant Staphylococcus aureus in three patients, with no organism isolated in the remaining cases. There was no loss of limb following gradual snare occlusion but there was only one death due to aortic stump rupture 2 weeks later. Gradual snare occlusion is an alternative for the management of chronic or recurrent graft infection. Copyright 1999 Harcourt Publishers Ltd.

  16. Feasibility study on retinal vascular bypass surgery in isolated arterially perfused caprine eye model

    PubMed Central

    Chen, Y; Wu, W; Zhang, X; Fan, W; Shen, L

    2011-01-01

    Purpose To investigate the feasibility of bypassing occluded segments of retinal venous main vessels in isolated, arterially perfused caprine eyes via the closed-sky vitrectomy approach using keratoprosthesis. Methods Isolated caprine eyes were used in this study. For each eye, the retinal vessel was perfused by Krebs solution via ophthalmic artery, and pars plana vitrectomy was performed using temporary keratoprosthesis. All retinal micro-vascular maneuvers were performed in a closed-sky eyeball. The main retinal vein was blocked by endodiathermy at the site of the vessel's first branching. Two openings, several millimeters apart, were created by vascular punctures in both the main vein and its branch vein wall straddling the induced occluded segment. Catheterization was achieved using a flexible polyimide tube, with each end inserted into the vessel wall opening. A sealed connection between the vessel and the tube was obtained by endodiathermy. Bypass of the occluded retinal vein segment was thus achieved, and the patency of this vascular bypass was confirmed by intravascular staining. Results Puncturing, catheterization, and endodiathermy were viable by closed-sky approach using keratoprosthesis. Bypassing of the occluded retinal main vein segment was accomplished with the combination of these maneuvers. Good results were obtained in 23 of 38 (60%) caprine eyes. Conclusions This study demonstrated that bypassing the occluded segment of retinal main vein can be successfully performed in a closed-sky eyeball model of isolated, arterially perfused caprine eye. This early work indicated that the more advanced retinal vascular bypass surgery in in vivo eye may be feasible in the future. PMID:21921946

  17. Off-pump versus on-pump coronary artery bypass surgery in patients with actively treated diabetes and multivessel coronary disease.

    PubMed

    Benedetto, Umberto; Caputo, Massimo; Vohra, Hunaid; Davies, Alan; Hillier, James; Bryan, Alan; Angelini, Gianni D

    2016-11-01

    We conducted a single-center analysis on short-term outcomes and long-term survival in actively treated diabetic patients undergoing off-pump coronary artery bypass versus on-pump coronary artery bypass surgery. The final population consisted of 2450 patients with actively treated diabetes (mean age, 66 ± 9 years; female/male 545/1905, 22%). Of those, 1493 subjects were orally treated and 1011 subjects were taking insulin. Off-pump coronary artery bypass and on-pump coronary artery bypass were performed in 1253 and 1197 patients, respectively. Propensity score matching was used to compare the 2 matched groups. When compared with on-pump coronary artery bypass, off-pump coronary artery bypass was associated with a significant risk reduction for postoperative cerebrovascular accident (odds ratio, 0.49; 95% confidence interval [CI], 0.25-0.99; P = .04), need for postoperative intra-aortic balloon pump (odds ratio, 0.48; 95% CI, 0.30-0.77; P = .002), and reexploration for bleeding (odds ratio, 0.55; 95% CI, 0.33-0.94; P = .02). Off-pump coronary artery bypass did not significantly affect early (hazard ratio [HR], 1.32; 95% CI, 0.73-2.40; P = .36) and late (HR, 1.08; 95% CI, 0.92-1.28; P = .32) mortality. However, off-pump coronary artery bypass with incomplete revascularization was associated with reduced survival when compared with off-pump coronary artery bypass with complete revascularization (HR, 1.82; 95% CI, 1.34-2.46; P = .0002) and on-pump coronary artery bypass with complete revascularization (HR, 1.83; 95% CI, 1.36-2.47; P < .0001). Off-pump coronary artery bypass is a safe and feasible option for diabetic patients with multivessel disease, reduces the incidence of early complications including postoperative cerebrovascular events, and provides excellent long-term survival similar to on-pump coronary artery bypass surgery in case of complete revascularization. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  18. Superficial Temporal Artery-Superior Cerebellar Artery Bypass with Anterior Petrosectomy.

    PubMed

    Hokari, Masaaki; Asaoka, Katsuyuki; Shimbo, Daisuke; Uchida, Kazuki; Itamoto, Koji

    2018-06-01

    Superficial temporal artery (STA) to superior cerebellar artery (SCA) bypass is associated with a relatively high risk of surgical complications, such as hematoma and/or edema caused by temporal lobe retraction. Therefore, the right side is typically used to avoid retraction of the left temporal lobe. In this report, we present a case of left STA-SCA bypass with anterior petrosectomy to avoid retraction of dominant-side temporal lobe and describe the surgical technique in detail. A 69-year-old man presented with gradual worsening of dysarthria and gait disturbance. Magnetic resonance imaging showed no signs of acute infarction, but digital subtraction angiography showed severe stenosis of basilar artery and faint flow in the distal basilar artery. On 3-dimensional computed tomography angiography, posterior communicating arteries were not visualized; we could identify the left SCA, but not the right SCA. Despite dual antiplatelet therapy, a small fresh brainstem infarct was detected 10 days after admission. To avert fatal brainstem infarction and further enlargement of the infarct, we performed left STA-SCA bypass with anterior petrosectomy to avoid retraction of the dominant-side temporal lobe. Postoperative imaging revealed no new lesions, such as infarction or temporal lobe contusional hematoma, and confirmed the patency of the bypass. Postoperative single-photon emission computed tomography demonstrated improved cerebral blood flow in the posterior circulation. The patient was transferred to another hospital for rehabilitation. This method helps minimize the risk of injury to the temporal lobe, especially that of the dominant side. Copyright © 2018. Published by Elsevier Inc.

  19. Internal to external jugular vein bypass allowing for simultaneous bilateral radical neck dissection.

    PubMed

    Mourad, Moustafa; Saman, Masoud; Ducic, Yadranko

    2015-11-01

    The goal of the study was to determine the role of internal jugular vein (IJV) to external jugular vein (EJV) bypass grafting in the setting of bilateral radical neck dissection with IJV sacrifice. The study group consisted of eight patients who underwent bilateral radical neck dissection with IJV sacrifice. Demographic and oncologic parameters were defined for each patient, including age, gender, and pathology. Patients were monitored and evaluated for potential effects of increased intracranial pressure (ICP). Doppler ultrasonic evaluation was performed to assess patency of the site of anastamoses. In all, six patients underwent unilateral bypass grafting, whereas two patients underwent bilateral bypass grafts. Average age at time of surgery was 68.2 (range 56-71). Postoperatively, no sequelae of increased ICP were noted. Follow-up ultrasonic evaluation revealed patent vessels in all patients. We presently report on the use of EJV-to-IJV bypass grafting for all patients undergoing bilateral radical neck dissection for extensive neck disease. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Effect of acetylcysteine on adaptation of intestinal smooth muscle after small bowel bypass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weisbrodt, N.W.; Belloso, R.M.; Biskin, L.C.

    1986-03-05

    The authors have postulated that the adaptive changes in function and structure of bypassed segments of small bowel are due in part to the change in intestinal contents following operation. The purpose of these experiments was to determine if a mucolytic agent could alter the adaptation. Rats were anesthetized and a 70% jejunoileal bypass was performed. The bypassed segments then were perfused with either saline or acetylcysteine for 3-12 days. Then, either intestinal transit was determined using Cr-51, or segments were taken for morphometric analysis. Transit, as assessed by the geometric center, was increased 32% by acetylcysteine treatment. Treatment alsomore » caused a decrease in hypertrophy of the muscularis. Muscle wet weight, muscle cross-sectional area, and muscle layer thickness all were significantly less in those animals infused with acetyl-cysteine. No decreases in hypertrophy were seen in the in-continuity segments. These data indicate that alterations in intestinal content can affect the course of adaptation of intestinal muscle in response to small bowel bypass.« less

  1. Diffuse large B-cell lymphoma (DLBCL) in the bypassed stomach after obesity surgery.

    PubMed

    Courtney, M J; Chattopadhyay, D; Rao, M; Light, D; Gopinath, B

    2014-04-01

    Laparoscopic Roux-en-Y gastric bypass is the most commonly performed surgical procedure for obesity and, consequently, post-operative patients are increasingly encountered by all specialties. This is a case of a patient presenting with abdominal pain, nausea and fever 9 months following gastric bypass surgery caused by diffuse large B-cell lymphoma (DLBCL) in the bypassed stomach. It demonstrates well that symptoms that may normally be considered 'red-flags' may not be as obvious or specific following an operation. The case also indicates the importance of considering diagnoses unrelated to surgery presenting in the post-operative period (especially when conventional investigation methods are not feasible), and the potential danger of assuming they are due to the operation alone; had this occurred in this patient then a malignancy may have been missed. This is only the second reported case of DLBCL in the bypassed stomach, and the third for lymphoma of any type. © 2014 The Authors. Clinical Obesity © 2014 International Association for the Study of Obesity.

  2. Low level vapor verification of monomethyl hydrazine

    NASA Technical Reports Server (NTRS)

    Mehta, Narinder

    1990-01-01

    The vapor scrubbing system and the coulometric test procedure for the low level vapor verification of monomethyl hydrazine (MMH) are evaluated. Experimental data on precision, efficiency of the scrubbing liquid, instrument response, detection and reliable quantitation limits, stability of the vapor scrubbed solution, and interference were obtained to assess the applicability of the method for the low ppb level detection of the analyte vapor in air. The results indicated that the analyte vapor scrubbing system and the coulometric test procedure can be utilized for the quantitative detection of low ppb level vapor of MMH in air.

  3. Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Lstiburek, J. W.

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane.more » As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).« less

  4. The History and Evolution of Internal Maxillary Artery Bypass.

    PubMed

    Wang, Long; Cai, Li; Lu, Shuaibin; Qian, Hai; Lawton, Michael T; Shi, Xiang'en

    2018-05-01

    Internal maxillary artery (IMA) bypass has gained momentum in the last 5 years for the treatment of complex cerebrovascular disorders and skull base tumors. However, some issues regarding this treatment modality have been proposed. As one of the most experienced neurosurgical teams to perform internal maxillary artery bypass in the world (>100 clinical cases), we reviewed the literature in aspects of basic anatomy of maxillary artery with its variations to the lateral pterygoid muscle, initial anastomosis modalities, and subsequent exposure techniques in cadaver studies, preoperative arterial evaluation methods, optimal interposed graft selections, and surgical outcome in the management of complex aneurysms, skull base tumors, and steno-occlusive disorders. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Vapor pressures of new fluorocarbons

    NASA Astrophysics Data System (ADS)

    Kubota, H.; Yamashita, T.; Tanaka, Y.; Makita, T.

    1989-05-01

    The vapor pressures of four fluorocarbons have been measured at the following temperature ranges: R123 (2,2-dichloro-l,l,l-trifluoroethane), 273 457 K; R123a (1,2-dichloro-1,1,2-trifluoroethane), 303 458 K; R134a (1,1,1,2-tetrafluoroethane), 253 373 K; and R132b (l,2-dichloro-l,l-difluoroethane), 273 398 K. Determinations of the vapor pressure were carried out by a constant-volume apparatus with an uncertainty of less than 1.0%. The vapor pressures of R123 and R123a are very similar to those of R11 over the whole experimental temperature range, but the vapor pressures of R134a and R132b differ somewhat from those of R12 and R113, respectively, as the temperature increases. The numerical vapor pressure data can be fitted by an empirical equation using the Chebyshev polynomial with a mean deviation of less than 0.3 %.

  6. Vapor pressures of new fluorocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubota, H.; Yamashita, T.; Tanaka, Y.

    1989-05-01

    The vapor pressures of four fluorocarbons have been measured at the following temperature ranges: R123 (2,2-dichloro-1,1,1-trifluoroethane), 273-457 K; R123a (1,2-dichloro-1,1,2-trifluoroethane), 303-458 K; R134a (1,1,1,2-tetrafluoroethane), 253-373 K; and R132b (1,2-dichloro-1,1-difluoroethane), 273-398 K. Determinations of the vapor pressure were carried out by a constant-volume apparatus with an uncertainty of less than 1.0%. The vapor pressures of R123 and R123a are very similar to those of R11 over the whole experimental temperature range, but the vapor pressures of R134a and R132b differ somewhat from those of R12 and R113, respectively, as the temperature increases. The numerical vapor pressure data can be fitted bymore » an empirical equation using the Chebyshev polynomial with a mean deviation of less than 0.3%.« less

  7. DSMC simulations of vapor transport toward development of the lithium vapor box divertor concept

    NASA Astrophysics Data System (ADS)

    Jagoe, Christopher; Schwartz, Jacob; Goldston, Robert

    2016-10-01

    The lithium vapor divertor box concept attempts to achieve volumetric dissipation of the high heat efflux from a fusion power system. The vapor extracts the heat of the incoming plasma by ionization and radiation, while remaining localized in the vapor box due to differential pumping based on rapid condensation. Preliminary calculations with lithium vapor at densities appropriate for an NSTX-U-scale machine give Knudsen numbers between 0.01 and 1, outside both the range of continuum fluid dynamics and of collisionless Monte Carlo. The direct-simulation Monte Carlo (DSMC) method, however, can simulate rarefied gas flows in this regime. Using the solver contained in the OpenFOAM package, pressure-driven flows of water vapor will be analyzed. The use of water vapor in the relevant range of Knudsen number allows for a flexible similarity experiment to verify the reliability of the code before moving to tests with lithium. The simulation geometry consists of chains of boxes on a temperature gradient, connected by slots with widths that are a representative fraction of the dimensions of the box. We expect choked flow, sonic shocks, and order-of-magnitude pressure and density drops from box to box, but this expectation will be tested in the simulation and then experiment. This work is supported by the Princeton Environmental Institute.

  8. Water Vapor Feedbacks to Climate Change

    NASA Technical Reports Server (NTRS)

    Rind, David

    1999-01-01

    The response of water vapor to climate change is investigated through a series of model studies with varying latitudinal temperature gradients, mean temperatures, and ultimately, actual climate change configurations. Questions to be addressed include: what role does varying convection have in water vapor feedback; do Hadley Circulation differences result in differences in water vapor in the upper troposphere; and, does increased eddy energy result in greater eddy vertical transport of water vapor in varying climate regimes?

  9. Binary breath figures for straightforward and controllable self-assembly of microspherical caps.

    PubMed

    Gong, Jianliang; Xu, Bingang; Tao, Xiaoming; Li, Lei

    2016-05-11

    The intense interest surrounding asymmetrical microparticles originates from their unique anisotropic properties and promising applications. In this work, direct self-assembly of polymeric microspherical caps without the assistance of any additives has been achieved by using low-surface-tension methanol (MeOH) and high-surface-tension water as binary breath figures (BFs). With the evaporation of polystyrene (PS) solution containing low-boiling-point solvent in the binary vapors, the formed MeOH BFs could quickly diffuse into solution, while water BFs tended to remain at the solution surface. This led to the formation of a gradient nonsolvent layer at the vapor/solution interface, which induced the formation of nuclei and guided further asymmetrical growth of polymer particles. After the spontaneous removal of MeOH, water and residual solvent by evaporation, polymeric microspherical caps were left on the substrate. Through controlling the proportion of water introduced by adjusting the ratios of MeOH and water, polymeric microspherical caps with a range of controllable shapes (divided at different positions of a sphere) were successfully obtained. The formation mechanism was explained based on the difference of vapor pressure, surface tension and miscibility between the employed solvents and nonsolvents. A solvent possessing a high vapor pressure, low surface tension and good miscibility with MeOH contributed to the formation of microspherical caps. This flexible, green and straightforward technique is a nondestructive strategy, and avoids complicated work on design, preparation and removal of hard templates and additives.

  10. Acoustically-Enhanced Direct Contact Vapor Bubble Condensation

    NASA Astrophysics Data System (ADS)

    Boziuk, Thomas; Smith, Marc; Glezer, Ari

    2017-11-01

    Rate-limited, direct contact vapor condensation of vapor bubbles that are formed by direct steam injection through a nozzle in a quiescent subcooled liquid bath is accelerated using ultrasonic (MHz-range) actuation. A submerged, low power actuator produces an acoustic beam whose radiation pressure deforms the liquid-vapor interface, leading to the formation of a liquid spear that penetrates the vapor bubble to form a vapor torus with a significantly larger surface area and condensation rate. Ultrasonic focusing along the spear leads to the ejection of small, subcooled droplets through the vapor volume that impact the vapor-liquid interface and further enhance the condensation. High-speed Schlieren imaging of the formation and collapse of the vapor bubbles in the absence and presence of actuation shows that the impulse associated with the collapse of the toroidal volume leads to the formation of a turbulent vortex ring in the liquid phase. Liquid motions near the condensing vapor volume are investigated in the absence and presence of acoustic actuation using high-magnification PIV and show the evolution of a liquid jet through the center of the condensing toroidal volume and the formation and advection of vortex ring structures whose impulse appear to increase with temperature difference between the liquid and vapor phases. High-speed image processing is used to assess the effect of the actuation on the temporal and spatial variations in the characteristic scales and condensation rates of the vapor bubbles.

  11. Petroleum Vapor - Field Technical

    EPA Science Inventory

    The screening approach being developed by EPA OUST to evaluate petroleum vapor intrusion (PVI) requires information that has not be routinely collected in the past at vapor intrusion sites. What is the best way to collect this data? What are the relevant data quality issues and ...

  12. Thermodynamic Cycle Analysis of Magnetohydrodynamic-Bypass Hypersonic Airbreathing Engines

    NASA Technical Reports Server (NTRS)

    Litchford, R. J.; Cole, J. W.; Bityurin, V. A.; Lineberry, J. T.

    2000-01-01

    The prospects for realizing a magnetohydrodynamic (MHD) bypass hypersonic airbreathing engine are examined from the standpoint of fundamental thermodynamic feasibility. The MHD-bypass engine, first proposed as part of the Russian AJAX vehicle concept, is based on the idea of redistributing energy between various stages of the propulsion system flow train. The system uses an MHD generator to extract a portion of the aerodynamic heating energy from the inlet and an MHD accelerator to reintroduce this power as kinetic energy in the exhaust stream. In this way, the combustor entrance Mach number can be limited to a specified value even as the flight Mach number increases. Thus, the fuel and air can be efficiently mixed and burned within a practical combustor length, and the flight Mach number operating envelope can be extended. In this paper, we quantitatively assess the performance potential and scientific feasibility of MHD-bypass engines using a simplified thermodynamic analysis. This cycle analysis, based on a thermally and calorically perfect gas, incorporates a coupled MHD generator-accelerator system and accounts for aerodynamic losses and thermodynamic process efficiencies in the various engin components. It is found that the flight Mach number range can be significantly extended; however, overall performance is hampered by non-isentropic losses in the MHD devices.

  13. Flow Simulation of Supersonic Inlet with Bypass Annular Duct

    NASA Technical Reports Server (NTRS)

    Kim, HyoungJin; Kumano, Takayasu; Liou, Meng-Sing; Povinelli, Louis A.; Conners, Timothy R.

    2011-01-01

    A relaxed isentropic compression supersonic inlet is a new concept that produces smaller cowl drag than a conventional inlet, but incurs lower total pressure recovery and increased flow distortion in the (radially) outer flowpath. A supersonic inlet comprising a bypass annulus to the relaxed isentropic compression inlet dumps out airflow of low quality through the bypass duct. A reliable computational fluid dynamics solution can provide considerable useful information to ascertain quantitatively relative merits of the concept, and further provide a basis for optimizing the design. For a fast and reliable performance evaluation of the inlet performance, an equivalent axisymmetric model whose area changes accounts for geometric and physical (blockage) effects resulting from the original complex three-dimensional configuration is proposed. In addition, full three-dimensional calculations are conducted for studying flow phenomena and verifying the validity of the equivalent model. The inlet-engine coupling is carried out by embedding numerical propulsion system simulation engine data into the flow solver for interactive boundary conditions at the engine fan face and exhaust plane. It was found that the blockage resulting from complex three-dimensional geometries in the bypass duct causes significant degradation of inlet performance by pushing the terminal normal shock upstream.

  14. Impact Vaporization of Planetesimal Cores

    NASA Astrophysics Data System (ADS)

    Kraus, R. G.; Root, S.; Lemke, R. W.; Stewart, S. T.; Jacobsen, S. B.; Mattsson, T. R.

    2013-12-01

    The degree of mixing and chemical equilibration between the iron cores of planetesimals and the mantle of the growing Earth has important consequences for understanding the end stages of Earth's formation and planet formation in general. At the Sandia Z machine, we developed a new shock-and-release technique to determine the density on the liquid-vapor dome of iron, the entropy on the iron shock Hugoniot, and the criteria for shock-induced vaporization of iron. We find that the critical shock pressure to vaporize iron is 507(+65,-85) GPa and show that decompression from a 15 km/s impact will initiate vaporization of iron cores, which is a velocity that is readily achieved at the end stages of planet formation. Vaporization of the iron cores increases dispersal of planetesimal cores, enables more complete chemical equilibration of the planetesimal cores with Earth's mantle, and reduces the highly siderophile element abundance on the Moon relative to Earth due to the expanding iron vapor exceeding the Moon's escape velocity. Sandia National Laboratories is a multiprogram laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Securities Administration under Contract No. DE-AC04-94AL85000.

  15. Massive sediment bypassing on the lower shoreface offshore of a wide tidal inlet: Cat Island Pass, Louisiana

    USGS Publications Warehouse

    Jaffe, B.E.; List, J.H.; Sallenger, A.H.

    1997-01-01

    Analysis of a series of historical bathymetric and shoreline surveys along the Louisiana coast west of the Mississippi River mouth detected a large area of deposition in water depths of 2.0–8.5 m offshore of a 9-km-wide tidal inlet, the Cat Island Pass/Wine Island Pass system. A 59.9 · 106 m3 sandy deposit formed from the 1930s–1980s, spanning 27 km in the alongshore direction, delineating the transport pathway for sediment bypassing offshore of the inlet on the shoreface. Bypassing connected the shorefaces of two barrier island systems, the Isles Dernieres and the Bayou Lafourche.The processes responsible for formation of this deposit are not well understood, but sediment-transport modeling suggests that sediment is transported primarily by wind-driven coastal currents during large storms and hurricanes. Deposition appears to be related to changes in shoreline orientation, closing of transport pathways into a large bay to the east and the presence of tidal inlets. This newly documented type of bypassing, an offshore bypassing of the inlet system, naturally nourished the immediate downdrift area, the eastern Isles Dernieres, where shoreface and shoreline erosion rates are about half of pre-bypassing rates. Erosion rates remained the same farther downdrift, where bypassing has not yet reached. As this offshore bypassing continues, the destruction of the Isles Dernieres will be slowed.

  16. In situ cephalic vein bypasses from axillary to the brachial artery after catheterization injuries.

    PubMed

    Hudorovic, Narcis; Lovricevic, Ivo; Ahel, Zaky

    2010-07-01

    The need to bypass to the brachial artery is rare. Over a five-year period, 16 patients had suffered iatrogenic post-catheterization injuries of the upper extremity. We have performed 16 bypasses, in 16 patients, mean age was 65 years (range 47-75), to the brachial artery originating from an artery proximal to the shoulder joint. In all cases, the axillary artery was the donor artery. All bypasses were created by using the cephalic vein with the in situ technique and distal anastomoses were made to a distance-free section of brachial artery. No operative mortality, neurological complications or major upper-extremity amputation was associated with the procedure. Life-long-conduit analysis showed 75% patency in the five-year period. After iatrogenic post-catheterization trauma of arterial system of upper extremity, bypasses from axillary to brachial artery with the cephalic vein with the in situ technique is a safe operation with satisfactory long-term patency.

  17. 21 CFR 868.1975 - Water vapor analyzer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Water vapor analyzer. 868.1975 Section 868.1975...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1975 Water vapor analyzer. (a) Identification. A water vapor analyzer is a device intended to measure the concentration of water vapor in a...

  18. 21 CFR 868.1975 - Water vapor analyzer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Water vapor analyzer. 868.1975 Section 868.1975...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1975 Water vapor analyzer. (a) Identification. A water vapor analyzer is a device intended to measure the concentration of water vapor in a...

  19. 21 CFR 868.1975 - Water vapor analyzer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Water vapor analyzer. 868.1975 Section 868.1975...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1975 Water vapor analyzer. (a) Identification. A water vapor analyzer is a device intended to measure the concentration of water vapor in a...

  20. 21 CFR 868.1975 - Water vapor analyzer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Water vapor analyzer. 868.1975 Section 868.1975...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1975 Water vapor analyzer. (a) Identification. A water vapor analyzer is a device intended to measure the concentration of water vapor in a...

  1. 21 CFR 868.1975 - Water vapor analyzer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Water vapor analyzer. 868.1975 Section 868.1975...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1975 Water vapor analyzer. (a) Identification. A water vapor analyzer is a device intended to measure the concentration of water vapor in a...

  2. Aspirin resistance in patients with hemodynamic cerebral ischemia undergoing extracranial-intracranial bypass surgery.

    PubMed

    Jussen, Daniel; Horn, Peter; Vajkoczy, Peter

    2013-01-01

    Aspirin (acetylsalicylic acid, ASA) is the treatment of choice for prevention of vascular events in symptomatic steno-occlusive cerebrovascular disease (CVD). Cerebral revascularization using standard extracranial-intracranial (EC-IC) bypass surgery may be used to revert hemodynamic compromise. Aspirin is prescribed as standard medication in order to avoid bypass failure. Accumulating evidence of an increased risk of major adverse clinical events led to this study, in which we aimed to assess the prevalence of aspirin resistance and prothrombotic disorders among patients scheduled for EC-IC bypass surgery, and the effectiveness of aspirin dose escalation. We prospectively screened patients with circumscribed high-grade stenosis or occlusion of brain-supplying vessels fulfilling the hemodynamic criteria for EC-IC bypass surgery for aspirin resistance using a platelet function analyzer (PFA-100®) test. We also determined their smoking habits and screened for prothrombotic disorders and comorbidities. The patients were divided into 2 major groups: group A had atherosclerotic steno-occlusive CVD and group B consisted of patients with nonatherosclerotic steno-occlusive CVD (moyamoya disease) and a subgroup of pediatric moyamoya patients (pediatric subgroup). Bypass patency was documented via digital subtraction angiography. Standard initial ASA dose applied was 100 mg/day. In cases of aspirin resistance, doses were increased and the PFA-100 test was repeated. A total of 56 patients were included over a time period of 6 months. In group A (n = 25), we found a ratio of 40% of patients with primary resistance to aspirin 100 mg/day. In contrast, in group B (n = 25), only 20% of the patients were resistant to aspirin 100 mg/day; in the pediatric population (n = 6), there was no primary aspirin resistance. After a dose escalation to 300 mg/day, the ratio of aspirin resistance was reduced to 20% in group A and to 0% in group B. Altogether 5 patients with atherosclerotic steno

  3. Augmented reality-assisted bypass surgery: embracing minimal invasiveness.

    PubMed

    Cabrilo, Ivan; Schaller, Karl; Bijlenga, Philippe

    2015-04-01

    The overlay of virtual images on the surgical field, defined as augmented reality, has been used for image guidance during various neurosurgical procedures. Although this technology could conceivably address certain inherent problems of extracranial-to-intracranial bypass procedures, this potential has not been explored to date. We evaluate the usefulness of an augmented reality-based setup, which could help in harvesting donor vessels through their precise localization in real-time, in performing tailored craniotomies, and in identifying preoperatively selected recipient vessels for the purpose of anastomosis. Our method was applied to 3 patients with Moya-Moya disease who underwent superficial temporal artery-to-middle cerebral artery anastomoses and 1 patient who underwent an occipital artery-to-posteroinferior cerebellar artery bypass because of a dissecting aneurysm of the vertebral artery. Patients' heads, skulls, and extracranial and intracranial vessels were segmented preoperatively from 3-dimensional image data sets (3-dimensional digital subtraction angiography, angio-magnetic resonance imaging, angio-computed tomography), and injected intraoperatively into the operating microscope's eyepiece for image guidance. In each case, the described setup helped in precisely localizing donor and recipient vessels and in tailoring craniotomies to the injected images. The presented system based on augmented reality can optimize the workflow of extracranial-to-intracranial bypass procedures by providing essential anatomical information, entirely integrated to the surgical field, and help to perform minimally invasive procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Results of The Comparative Study of 200 Cases: One Anastomosis Gastric Bypass vs Roux-en-Y Gastric Bypass.

    PubMed

    Navarrete, Salvador; Leyba, José Luis; Ll, Salvador Navarrete; Borjas, Guillermo; Tapia, José León; Alcázar, Ruben

    2018-05-01

    Obesity has experienced worldwide increase and surgery has become the treatment that has achieved the best results. Several techniques have been described; the most popular are vertical gastrectomy (GV) and the Roux-en-Y gastric bypass (RYGB). However, mini-gastric bypass/one anastomosis gastric bypass (MGB/OAGB) has gained popularity due to its simplicity and good results. To comparatively evaluate the results of MGB/OAGB with those of RYGB with 1-year follow-up. The paper presents a comparative case and control study of 100 patients that underwent MGB/OAGB surgery and another 100 with RYGB surgery, operated between 2008 and 2016. Patients were not submitted to revision surgery and had the following pre-operative variables: age 40.46 ± 12.4 vs. 39.43 ± 10.33 years; sex 64 and 54 women, 36 and 46 men; BMI 44.8 ± 12.06 and 45.29 ± 8.82 kg/m 2 ; 50 and 54 cases with comorbidities, respectively, these being non-significant differences. The surgical time was 69.01 ± 4.62 (OAGB) vs. 88.98 ± 3.44 min; the time of hospitalization was 2 days, reaching a BMI of 27.7 ± 7.85 and 29 ± 4.52 kg/m 2 , with an excess weight loss 1 year after surgery of 89.4 vs. 85.9%, respectively. The morbidity rates are 9% for OAGB and 11% for the RYGB. There was a comorbidity resolution of 84.4 and 83.7% respectively, without mortality. The results show the benefits of both techniques, OAGB being the easiest to perform and with less surgical time.

  5. Advanced esophageal cancer with tracheobronchial fistula successfully treated by esophageal bypass surgery.

    PubMed

    Kimura, Masahiro; Ishiguro, Hideyuki; Tanaka, Tatsuya; Takeyama, Hiromitsu

    2015-01-01

    When esophageal cancer infiltrates the respiratory tract and forms a fistula, a patient's quality of life falls remarkably. Abstinence from oral feeding is necessary to prevent respiratory complications including pneumonia. Surgery is sometimes necessary to maintain quality of life. The aim of this study was to examine clinical outcomes of esophageal cancer complicated by tracheobronchial fistula. Twelve patients who underwent esophageal bypass between 2006 and 2011 in our hospital were studied. Patient characteristics, therapeutic course, outcome, and operation type were compared. Six patients among 8 who could not tolerate oral feeding could do so after bypass surgery. Ten patients were able to enjoy oral intake up until the last few days of life. Three patients survived for more than 10 months. In spite of undergoing an operation, 1 patient survived for only 2 months and another for 4 months. The only complication was postoperative delirium in 1 patient. While surgical bypass is more invasive than procedures such as endoscopic stenting, we had few complications after operative intervention and were able to maintain quality of life in our patients. This bypass procedure is a treatment option for patients with tracheobronchial fistula from advanced esophageal cancer. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. The lithium vapor box divertor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldston, R. J.; Myers, R.; Schwartz, J.

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Our recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m -2, implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et almore » as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. Furthermore, at the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required in order to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma.« less

  7. The lithium vapor box divertor

    NASA Astrophysics Data System (ADS)

    Goldston, R. J.; Myers, R.; Schwartz, J.

    2016-02-01

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m-2, implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. At the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma.

  8. The lithium vapor box divertor

    DOE PAGES

    Goldston, R. J.; Myers, R.; Schwartz, J.

    2016-01-13

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Our recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m -2, implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et almore » as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. Furthermore, at the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required in order to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma.« less

  9. Tests of by-pass diodes at cryogenic temperatures for the KATRIN magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gil, W.; Bolz, H.; Jansen, A.

    The Karlsruhe Tritium Neutrino experiment (KATRIN) requires a series of superconducting solenoid magnets for guiding beta-electrons from the source to the detector. By-pass diodes will operate at liquid helium temperatures to protect the superconducting magnets and bus bars in case of quenches. The operation conditions of the by-pass diodes depend on the different magnet systems of KATRIN. Therefore, different diode stacks are designed with adequate copper heat sinks assuming adiabatic conditions. The by-pass diode stacks have been submitted to cold tests both at liquid nitrogen and liquid helium temperatures for checking operation conditions. This report presents the test set upmore » and first results of the diode characteristics at 300 K and 77 K, as well as of endurance tests of the diode stacks at constant current load at 77 K and 4.2 K.« less

  10. 46 CFR 56.20-20 - Valve bypasses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Valve bypasses. 56.20-20 Section 56.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES..., and of a material of the same nominal chemical composition and physical properties as that used for...

  11. 46 CFR 56.20-20 - Valve bypasses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Valve bypasses. 56.20-20 Section 56.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES..., and of a material of the same nominal chemical composition and physical properties as that used for...

  12. 46 CFR 56.20-20 - Valve bypasses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Valve bypasses. 56.20-20 Section 56.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES..., and of a material of the same nominal chemical composition and physical properties as that used for...

  13. 46 CFR 56.20-20 - Valve bypasses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Valve bypasses. 56.20-20 Section 56.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES..., and of a material of the same nominal chemical composition and physical properties as that used for...

  14. 46 CFR 56.20-20 - Valve bypasses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Valve bypasses. 56.20-20 Section 56.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES..., and of a material of the same nominal chemical composition and physical properties as that used for...

  15. Bypass diode integration

    NASA Technical Reports Server (NTRS)

    Shepard, N. F., Jr.

    1981-01-01

    Protective bypass diodes and mounting configurations which are applicable for use with photovoltaic modules having power dissipation requirements in the 5 to 50 watt range were investigated. Using PN silicon and Schottky diode characterization data on packaged diodes and diode chips, typical diodes were selected as representative for each range of current carrying capacity, an appropriate heat dissipating mounting concept along with its environmental enclosure was defined, and a thermal analysis relating junction temperature as a function of power dissipation was performed. In addition, the heat dissipating mounting device dimensions were varied to determine the effect on junction temperature. The results of the analysis are presented as a set of curves indicating junction temperature as a function of power dissipation for each diode package.

  16. SIMPLIFIED LAPAROSCOPIC GASTRIC BYPASS WITH GASTROJEJUNAL LINEAR MECHANICAL ANASTOMOSIS: TECHNICAL ASPECTS.

    PubMed

    Palermo, Mariano; Serra, Edgardo

    Gastric bypass is a restrictive and malabsorptive surgery. The restrictive part consists in the creation of a small gastric pouch. The gastrointestinal bypass serves as the malabsorptive element. To describe a simplified gastric bypass approach for morbid obese patients, showing our results, and also remarking the importance of this technique for reducing the learning curve. The patient is positioned in a split legs position and carefully strapped to the operating room table, with the surgeon between the patient's legs. Five trocars are inserted after pneumoperitoneum at the umbilicus. Dissection of the esophagogastric angle and lesser curvature is mandatory before the gastric pouch manufacturing. This pouch is done with two blue load staplers. Using a blue load linear stapler inserted only half way into the hole in the pouch is used to perform the gastrojejunal anastomosis and in order to create an anastomosis that is about 2 cm in length. A side-to-side jejunojejunostomy is done with a white load linear stapler. The last step of the gastric bypass consists in the cut of the jejunum between the two anastomosis with a white load linear stapler. Blue test is performed in order to detect leaks. From January 2012 to December 2015, 415 simplified RYGB were performed. Gender: 67% female and 33 % males. Average of BMI 44.7. Mean age was 42 years old. Mean operative time 79 min. 39 % of this sample had T2 diabetes. Regarding complications were observed, one fistula, one gastrojejunal stenosis and one obstruction due to a bezoar. The described technique is a simplified approach in which all the anastomosis are performed in the upper part of the abdomen, allowing the surgeons to be more systematized and avoiding them to make mistakes in the confection of the Roux-en-Y anastomosis. This simplified gastric bypass is a safe and reproducible technique. Bypass gástrico é cirurgia restritiva e malabsortiva. A parte restritiva consiste na criação de uma pequena bolsa g

  17. Hypothenar hammer syndrome and basilic bypass.

    PubMed

    Chander, R K; Phair, J; Oza, P; Patel, M; Balar, N

    2014-12-01

    We report a case of hypothenar hammer syndrome. The case presents necessary diagnostic measures and discusses the etiology of this syndrome. Additionally, the case reviews treatments, which culminated in the eventual use of ulnar artery bypass with autogenous basilica vein to treat and resolve the ischemic fingers of the patient. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Pretest predictions for degraded shutdown heat-removal tests in THORS-SHRS Assembly 1. [LMFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, S.D.; Carbajo, J.J.

    The recent modification of the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility at ORNL will allow testing of parallel simulated fuel assemblies under natural-convection and low-flow forced-convection conditions similar to those that might occur during a partial failure of the Shutdown Heat Removal System (SHRS) of an LMFBR. An extensive test program has been prepared and testing will be started in September 1983. THORS-SHRS Assembly 1 consists of two 19-pin bundles in parallel with a third leg serving as a bypass line and containing a sodium-to-sodium intermediate heat exchanger. Testing at low powers wil help indicate the maximum amount of heat thatmore » can be removed from the reactor core during conditions of degraded shutdown heat removal. The thermal-hydraulic behavior of the test bundles will be characterized for single-phase and two-phase conditions up to dryout. The influence of interassembly flow redistribution including transients from forced- to natural-convection conditions will be investigated during testing.« less

  19. Influence of Diabetes on Long-Term Coronary Artery Bypass Graft Patency.

    PubMed

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Rajeswaran, Jeevanantham; Riaz, Haris; Bakaeen, Faisal G; Lincoff, A Michael; Sabik, Joseph F

    2017-08-01

    Nearly 50% of patients undergoing coronary artery bypass grafting have diabetes. However, little is known about the influence of diabetes on long-term patency of bypass grafts. Because patients with diabetes have more severe coronary artery stenosis, we hypothesized that graft patency is worse in patients with than without diabetes. This study sought to examine the influence of diabetes on long-term patency of bypass grafts. From 1972 to 2011, 57,961 patients underwent primary isolated coronary artery bypass grafting. Of these, 1,372 pharmacologically treated patients with diabetes and 10,147 patients without diabetes had 15,887 postoperative angiograms; stenosis was quantified for 7,903 internal thoracic artery (ITA) grafts and 20,066 saphenous vein grafts. Status of graft patency across time was analyzed by longitudinal nonlinear mixed-effects modeling. ITA graft patency was stable over time and similar in patients with and without diabetes: at 1, 5, 10, and 20 years, 97%, 97%, 96%, and 96% in patients with diabetes, and 96%, 96%, 95%, and 93% in patients without diabetes, respectively (early p = 0.20; late p = 0.30). In contrast, saphenous vein graft patency declined over time and similarly in patients with and without diabetes: at 1, 5, 10, and 20 years, 78%, 70%, 57%, and 42% in patients with diabetes, and 82%, 72%, 58%, and 41% in patients without diabetes, respectively (early p < 0.002; late p = 0.60). After adjusting for patient characteristics, diabetes was associated with higher early patency of ITA grafts (odds ratio: 0.63; 95% confidence limits: 0.43 to 0.91; p = 0.013), but late patency of ITA grafts was similar in patients with and without diabetes (p = 0.80). Early and late patency of saphenous vein grafts were similar in patients with and without diabetes (early p = 0.90; late p = 0.80). Contrary to our hypothesis, diabetes did not influence long-term patency of bypass grafts. Use of ITA grafts should be maximized in patients

  20. Upregulated Op18/stathmin activity causes chromosomal instability through a mechanism that evades the spindle assembly checkpoint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmfeldt, Per; Sellin, Mikael E.; Gullberg, Martin, E-mail: Martin.Gullberg@molbiol.umu.se

    2010-07-15

    Op18/stathmin (Op18) is a microtubule-destabilizing protein that is phosphorylation-inactivated during mitosis and its normal function is to govern tubulin subunit partitioning during interphase. Human tumors frequently overexpress Op18 and a tumor-associated Q18{yields}E mutation has been identified that confers hyperactivity, destabilizes spindle microtubules, and causes mitotic aberrancies, polyploidization, and chromosome loss in K562 leukemia cells. Here we determined whether wild-type and mutant Op18 have the potential to cause chromosomal instability by some means other than interference with spindle assembly, and thereby bypassing the spindle assembly checkpoint. Our approach was based on Op18 derivatives with distinct temporal order of activity during mitosis,more » conferred either by differential phosphorylation inactivation or by anaphase-specific degradation through fusion with the destruction box of cyclin B1. We present evidence that excessive Op18 activity generates chromosomal instability through interference occurring subsequent to the metaphase-to-anaphase transition, which reduces the fidelity of chromosome segregation to spindle poles during anaphase. Similar to uncorrected merotelic attachment, this mechanism evades detection by the spindle assembly checkpoint and thus provides an additional route to chromosomal instability.« less