Sound propagation through a variable area duct - Experiment and theory
NASA Technical Reports Server (NTRS)
Silcox, R. J.; Lester, H. C.
1981-01-01
A comparison of experiment and theory has been made for the propagation of sound through a variable area axisymmetric duct with zero mean flow. Measurement of the acoustic pressure field on both sides of the constricted test section was resolved on a modal basis for various spinning mode sources. Transmitted and reflected modal amplitudes and phase angles were compared with finite element computations. Good agreement between experiment and computation was obtained over a wide range of frequencies and modal transmission variations. The study suggests that modal transmission through a variable area duct is governed by the throat modal cut-off ratio.
NASA Technical Reports Server (NTRS)
Miles, J. H.
1981-01-01
A predicted standing wave pressure and phase angle profile for a hard wall rectangular duct with a region of converging-diverging area variation is compared to published experimental measurements in a study of sound propagation without flow. The factor of 1/2 area variation used is sufficient magnitude to produce large reflections. The prediction is based on a transmission matrix approach developed for the analysis of sound propagation in a variable area duct with and without flow. The agreement between the measured and predicted results is shown to be excellent.
A non-local computational boundary condition for duct acoustics
NASA Technical Reports Server (NTRS)
Zorumski, William E.; Watson, Willie R.; Hodge, Steve L.
1994-01-01
A non-local boundary condition is formulated for acoustic waves in ducts without flow. The ducts are two dimensional with constant area, but with variable impedance wall lining. Extension of the formulation to three dimensional and variable area ducts is straightforward in principle, but requires significantly more computation. The boundary condition simulates a nonreflecting wave field in an infinite duct. It is implemented by a constant matrix operator which is applied at the boundary of the computational domain. An efficient computational solution scheme is developed which allows calculations for high frequencies and long duct lengths. This computational solution utilizes the boundary condition to limit the computational space while preserving the radiation boundary condition. The boundary condition is tested for several sources. It is demonstrated that the boundary condition can be applied close to the sound sources, rendering the computational domain small. Computational solutions with the new non-local boundary condition are shown to be consistent with the known solutions for nonreflecting wavefields in an infinite uniform duct.
A comparison of experiment and theory for sound propagation in variable area ducts
NASA Technical Reports Server (NTRS)
Nayfeh, A. H.; Kaiser, J. E.; Marshall, R. L.; Hurst, C. J.
1980-01-01
An experimental and analytical program has been carried out to evaluate sound suppression techniques in ducts that produce refraction effects due to axial velocity gradients. The analytical program employs a computer code based on the method of multiple scales to calculate the influence of axial variations due to slow changes in the cross-sectional area as well as transverse gradients due to the wall boundary layers. Detailed comparisons between the analytical predictions and the experimental measurements have been made. The circumferential variations of pressure amplitudes and phases at several axial positions have been examined in straight and variable area ducts, with hard walls and lined sections, and with and without a mean flow. Reasonable agreement between the theoretical and experimental results has been found.
NASA Technical Reports Server (NTRS)
Nayfeh, A. H.; Kaiser, J. E.; Marshall, R. L.; Hurst, L. J.
1978-01-01
The performance of sound suppression techniques in ducts that produce refraction effects due to axial velocity gradients was evaluated. A computer code based on the method of multiple scales was used to calculate the influence of axial variations due to slow changes in the cross-sectional area as well as transverse gradients due to the wall boundary layers. An attempt was made to verify the analytical model through direct comparison of experimental and computational results and the analytical determination of the influence of axial gradients on optimum liner properties. However, the analytical studies were unable to examine the influence of non-parallel ducts on the optimum linear conditions. For liner properties not close to optimum, the analytical predictions and the experimental measurements were compared. The circumferential variations of pressure amplitudes and phases at several axial positions were examined in straight and variable-area ducts, hard-wall and lined sections with and without a mean flow. Reasonable agreement between the theoretical and experimental results was obtained.
Ponderosa pine resin defenses and growth: metrics matter.
Hood, Sharon; Sala, Anna
2015-11-01
Bark beetles (Coleoptera: Curculionidae, Scolytinae) cause widespread tree mortality in coniferous forests worldwide. Constitutive and induced host defenses are important factors in an individual tree's ability to survive an attack and in bottom-up regulation of bark beetle population dynamics, yet quantifying defense levels is often difficult. For example, in Pinus spp., resin flow is important for resistance to bark beetles but is extremely variable among individuals and within a season. While resin is produced and stored in resin ducts, the specific resin duct metrics that best correlate with resin flow remain unclear. The ability and timing of some pine species to produce induced resin is also not well understood. We investigated (i) the relationships between ponderosa pine (Pinus ponderosa Lawson & C. Lawson) resin flow and axial resin duct characteristics, tree growth and physiological variables, and (ii) if mechanical wounding induces ponderosa pine resin flow and resin ducts in the absence of bark beetles. Resin flow increased later in the growing season under moderate water stress and was highest in faster growing trees. The best predictors of resin flow were nonstandardized measures of resin ducts, resin duct size and total resin duct area, both of which increased with tree growth. However, while faster growing trees tended to produce more resin, models of resin flow using only tree growth were not statistically significant. Further, the standardized measures of resin ducts, density and duct area relative to xylem area, decreased with tree growth rate, indicating that slower growing trees invested more in resin duct defenses per unit area of radial growth, despite a tendency to produce less resin overall. We also found that mechanical wounding induced ponderosa pine defenses, but this response was slow. Resin flow increased after 28 days, and resin duct production did not increase until the following year. These slow induced responses may allow unsuccessfully attacked or wounded trees to resist future bark beetle attacks. Forest management that encourages healthy, vigorously growing trees will also favor larger resin ducts, thereby conferring increased constitutive resistance to bark beetle attacks. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Mclallin, K. L.; Kofskey, M. G.; Civinskas, K. C.
1983-01-01
The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.
NASA Technical Reports Server (NTRS)
Mclallin, K. L.; Kofskey, M. G.; Wong, R. Y.
1982-01-01
An experimental evaluation of the aerodynamic performance of the axial flow, variable area stator power turbine stage for the Department of Energy upgraded automotive gas turbine engine was conducted in cold air. The interstage transition duct, the variable area stator, the rotor, and the exit diffuser were included in the evaluation of the turbine stage. The measured total blading efficiency was 0.096 less than the design value of 0.85. Large radial gradients in flow conditions were found at the exit of the interstage duct that adversely affected power turbine performance. Although power turbine efficiency was less than design, the turbine operating line corresponding to the steady state road load power curve was within 0.02 of the maximum available stage efficiency at any given speed.
NASA Technical Reports Server (NTRS)
Callegari, A. J.
1979-01-01
A nonlinear theory for sound propagation in variable area ducts carrying a nearly sonic flow is presented. Linear acoustic theory is shown to be singular and the detailed nature of the singularity is used to develop the correct nonlinear theory. The theory is based on a quasi-one dimensional model. It is derived by the method of matched asymptotic expansions. In a nearly chocked flow, the theory indicates the following processes to be acting: a transonic trapping of upstream propagating sound causing an intensification of this sound in the throat region of the duct; generation of superharmonics and an acoustic streaming effect; development of shocks in the acoustic quantities near the throat. Several specific problems are solved analytically and numerical parameter studies are carried out. Results indicate that appreciable acoustic power is shifted to higher harmonics as shocked conditions are approached. The effect of the throat Mach number on the attenuation of upstream propagating sound excited by a fixed source is also determined.
Counter Clockwise Rotation of Cylinder with Variable Position to Control Base Flows
NASA Astrophysics Data System (ADS)
Asadullah, Mohammed; Khan, S. A.; Asrar, Waqar; Sulaeman, E.
2018-05-01
Experimental study of supersonic base flow at Mach 2 has been carried out to see the effect of cylinder when rotated counter clockwise inside the dead zone at variable locations near its base to control base pressure for different level of expansion for area ratio 9. Active cylinder of 2 mm diameter rotating counter clockwise when seen from top, is mounted as a controller. Three locations are chosen from the side wall of square duct namely at 2, 4, 6 mm respectively and 8 mm from square nozzle exit in the base region to mount the controller. Base pressure in recirculation zone and wall pressure along the square duct length has been measured with and without control. The experiments were carried out for NPR 2, 3, 6, 7.8 and 8.5. Cylinder when rotated counter clockwise as an active controller were found to reduce the base drag as high as 62 percent at NPR 8.5 when located near to duct wall and 50 percent when located away from duct wall for the same NPR. For perfectly expanded flows at NPR 7.8 the reduction in base drag was 53 percent near duct wall and 44 percent near duct wall. The active controller was up to 19 percentage effective for over expanded flows near to duct wall and up to 12 percent when located away from duct wall. Also, the control did not adversely affect the flow field.
Single stage, low noise, advanced technology fan. Volume 1: Aerodynamic design
NASA Technical Reports Server (NTRS)
Sullivan, T. J.; Younghans, J. L.; Little, D. R.
1976-01-01
The aerodynamic design for a half-scale fan vehicle, which would have application on an advanced transport aircraft, is described. The single stage advanced technology fan was designed to a pressure ratio of 1.8 at a tip speed of 503 m/sec 11,650 ft/sec). The fan and booster components are designed in a scale model flow size convenient for testing with existing facility and vehicle hardware. The design corrected flow per unit annulus area at the fan face is 215 kg/sec sq m (44.0 lb m/sec sq ft) with a hub-tip ratio of 0.38 at the leading edge of the fan rotor. This results in an inlet corrected airflow of 117.9 kg/sec (259.9 lb m/sec) for the selected rotor tip diameter if 90.37 cm (35.58 in.). The variable geometry inlet is designed utilizing a combination of high throat Mach number and acoustic treatment in the inlet diffuser for noise suppression (hybrid inlet). A variable fan exhaust nozzle was assumed in conjunction with the variable inlet throat area to limit the required area change of the inlet throat at approach and hence limit the overall diffusion and inlet length. The fan exit duct design was primarily influenced by acoustic requirements, including length of suppressor wall treatment; length, thickness and position on a duct splitter for additional suppressor treatment; and duct surface Mach numbers.
NASA Technical Reports Server (NTRS)
Baumeister, K. J.; Eversman, W.; Astley, R. J.; White, J. W.
1981-01-01
Experimental data are presented for sound propagation in a simulated infinite hard wall duct with a large change in duct cross sectional area. The data are conveniently tabulated for further use. The 'steady' state finite element theory of Astley and Eversman (1981) and the transient finite difference theory of White (1981) are in good agreement with the data for both the axial and transverse pressure profiles and the axial phase angle. Therefore, numerical finite difference and finite element theories appear to be ideally suited for handling duct propagation problems which encounter large axial gradients in acoustic parameters. The measured energy reflection coefficient agrees with the values from the Astley-Eversman modal coupling model.
Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweet, M. L.; Francisco, A.; Roberts, S. G.
The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less
Sound transmission in ducts containing nearly choked flows
NASA Technical Reports Server (NTRS)
Callegari, A. J.; Myers, M. K.
1979-01-01
The nonlinear theory previously developed by the authors (1977, 1978) is used to obtain numerical results for sound transmission through a nearly choked throat in a variable-area duct. Parametric studies are performed for different source locations, strengths and frequencies. It is shown that the nonlinear interactions in the throat region generate superharmonics of the fundamental (source) frequency throughout the duct. The amplitudes of these superharmonics increase as the source parameters (frequency and strength) are increased toward values leading to acoustic shocks. For a downstream source, superharmonics carry about 20% of the total acoustic power as shocking conditions are approached. For the source strength levels and frequencies considered, streaming effects are negligible.
Pressure transfer function of a JT15D nozzle due to acoustic and convected entropy fluctuations
NASA Astrophysics Data System (ADS)
Miles, J. H.
An acoustic transmission matrix analysis of sound propagation in a variable area duct with and without flow is extended to include convected entropy fluctuations. The boundary conditions used in the analysis are a transfer function relating entropy and pressure at the nozzle inlet and the nozzle exit impedance. The nozzle pressure transfer function calculated is compared with JT15D turbofan engine nozzle data. The one dimensional theory for sound propagation in a variable area nozzle with flow but without convected entropy is good at the low engine speeds where the nozzle exit Mach number is low (M=0.2) and the duct exit impedance model is good. The effect of convected entropy appears to be so negligible that it is obscured by the inaccuracy of the nozzle exit impedance model, the lack of information on the magnitude of the convected entropy and its phase relationship with the pressure, and the scatter in the data. An improved duct exit impedance model is required at the higher engine speeds where the nozzle exit Mach number is high (M=0.56) and at low frequencies (below 120 Hz).
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Kochkin, M. Sweet
The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-02-01
The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk ofmore » condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.« less
Double-duct liquid metal magnetohydrodynamic engine
Haaland, Carsten M.
1995-01-01
An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has-four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.
Double-duct liquid metal magnetohydrodynamic engine
Haaland, Carsten M.
1997-01-01
An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.
Thrust control system design of ducted rockets
NASA Astrophysics Data System (ADS)
Chang, Juntao; Li, Bin; Bao, Wen; Niu, Wenyu; Yu, Daren
2011-07-01
The investigation of the thrust control system is aroused by the need for propulsion system of ducted rockets. Firstly the dynamic mathematical models of gas flow regulating system, pneumatic servo system and ducted rocket engine were established and analyzed. Then, to conquer the discussed problems of thrust control, the idea of information fusion was proposed to construct a new feedback variable. With this fused feedback variable, the thrust control system was designed. According to the simulation results, the introduction of the new fused feedback variable is valid in eliminating the contradiction between rapid response and stability for the thrust control system of ducted rockets.
NASA Technical Reports Server (NTRS)
George-Falvy, Dez
1992-01-01
Circumferential design combines compactness and efficiency. In remotely controlled valve, flow in tributary duct along circumference of primary duct merged with flow in primary duct. Flow in tributary duct regulated by variable throat nuzzle driven by worm gear. Design leak-proof, and most components easily fabricated on lathe.
Cystic pancreatic neoplasms evaluation by CT and magnetic resonance cholangiopancreatography.
Sahani, Dushyant; Prasad, Srinivasa; Saini, Sanjay; Mueller, Peter
2002-10-01
CT provides limited assistance in the differentiation between serous and mucinous neoplasms. Because of the variability in the radiographic appearance of serous cystadenomas and overlap in CT characteristics with mucinous neoplasms, most serous neoplasms still require ancillary testing such as biopsy to reach a definitive diagnosis. MRCP is useful in differentiating benign and malignant mucinous tumors including IPMT of the pancreas. The presence of mural nodules is suggestive of malignancy; however, the absence of mural nodules does not indicate that the tumor is benign. A maximum main pancreatic duct diameter of greater than 15 mm and diffuse dilatation of the main pancreatic duct are suggestive of malignancy in main duct-type tumors. Among branch duct-type tumors, malignant tumors tend to be larger than benign tumors; however, this finding is variable. The presence of main pancreatic duct dilatation may be helpful in determining malignancy of branch duct-type tumors.
Cholestasis‐induced adaptive remodeling of interlobular bile ducts
Damle‐Vartak, Amruta; Richter, Beate; Dirsch, Olaf; Dahmen, Uta; Hammad, Seddik
2016-01-01
Cholestasis is a common complication in liver diseases that triggers a proliferative response of the biliary tree. Bile duct ligation (BDL) is a frequently used model of cholestasis in rodents. To determine which changes occur in the three‐dimensional (3D) architecture of the interlobular bile duct during cholestasis, we used 3D confocal imaging, surface reconstructions, and automated image quantification covering a period up to 28 days after BDL. We show a highly reproducible sequence of interlobular duct remodeling, where cholangiocyte proliferation initially causes corrugation of the luminal duct surface, leading to an approximately five‐fold increase in surface area. This is analogous to the function of villi in the intestine or sulci in the brain, where an expansion of area is achieved within a restricted volume. The increase in surface area is further enhanced by duct branching, branch elongation, and loop formation through self‐joining, whereby an initially relatively sparse mesh surrounding the portal vein becomes five‐fold denser through elongation, corrugation, and ramification. The number of connections between the bile duct and the lobular bile canalicular network by the canals of Hering decreases proportionally to the increase in bile duct length, suggesting that no novel connections are established. The diameter of the interlobular bile duct remains constant after BDL, a response that is qualitatively distinct from that of large bile ducts, which tend to enlarge their diameters. Therefore, volume enhancement is only due to net elongation of the ducts. Because curvature and tortuosity of the bile duct are unaltered, this enlargement of the biliary tree is caused by branching and not by convolution. Conclusion: BDL causes adaptive remodeling that aims at optimizing the intraluminal surface area by way of corrugation and branching. (Hepatology 2016;63:951–964) PMID:26610202
Results of duct area ratio changes in the NASA Lewis H2-O2 combustion MHD experiment
NASA Technical Reports Server (NTRS)
Smith, J. M.
1979-01-01
MHD power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, generator loading B field strength, and electrode breakdown voltage were investigated. The effect of area ratio, multiple loading of the duct, and duct location within the magnetic field are considered.
Experiments in dilution jet mixing
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.; Berenfeld, A.
1983-01-01
Experimental results are given on the mixing of a single row of jets with an isothermal mainstream in a straight duct, to include flow and geometric variations typical of combustion chambers in gas turbine engines. The principal conclusions reached from these experiments were: at constant momentum ratio, variations in density ratio have only a second-order effect on the profiles; a first-order approximation to the mixing of jets with a variable temperature mainstream can be obtained by superimposing the jets-in-an isothermal-crossflow and mainstream profiles; flow area convergence, especially injection-wall convergence, significantly improves the mixing; for opposed rows of jets, with the orifice centerlines in-line, the optimum ratio of orifice spacing to duct height is one half of the optimum value for single side injection at the same momentum ratio; and for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single side injection at the same momentum ratio.
Aerodynamic/acoustic performance of YJ101/double bypass VCE with coannular plug nozzle
NASA Technical Reports Server (NTRS)
Vdoviak, J. W.; Knott, P. R.; Ebacker, J. J.
1981-01-01
Results of a forward Variable Area Bypass Injector test and a Coannular Nozzle test performed on a YJ101 Double Bypass Variable Cycle Engine are reported. These components are intended for use on a Variable Cycle Engine. The forward Variable Area Bypass Injector test demonstrated the mode shifting capability between single and double bypass operation with less than predicted aerodynamic losses in the bypass duct. The acoustic nozzle test demonstrated that coannular noise suppression was between 4 and 6 PNdB in the aft quadrant. The YJ101 VCE equipped with the forward VABI and the coannular exhaust nozzle performed as predicted with exhaust system aerodynamic losses lower than predicted both in single and double bypass modes. Extensive acoustic data were collected including far field, near field, sound separation/ internal probe measurements as Laser Velocimeter traverses.
Periodic Time-Domain Nonlocal Nonreflecting Boundary Conditions for Duct Acoustics
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Zorumski, William E.
1996-01-01
Periodic time-domain boundary conditions are formulated for direct numerical simulation of acoustic waves in ducts without flow. Well-developed frequency-domain boundary conditions are transformed into the time domain. The formulation is presented here in one space dimension and time; however, this formulation has an advantage in that its extension to variable-area, higher dimensional, and acoustically treated ducts is rigorous and straightforward. The boundary condition simulates a nonreflecting wave field in an infinite uniform duct and is implemented by impulse-response operators that are applied at the boundary of the computational domain. These operators are generated by convolution integrals of the corresponding frequency-domain operators. The acoustic solution is obtained by advancing the Euler equations to a periodic state with the MacCormack scheme. The MacCormack scheme utilizes the boundary condition to limit the computational space and preserve the radiation boundary condition. The success of the boundary condition is attributed to the fact that it is nonreflecting to periodic acoustic waves. In addition, transient waves can pass rapidly out of the solution domain. The boundary condition is tested for a pure tone and a multitone source in a linear setting. The effects of various initial conditions are assessed. Computational solutions with the boundary condition are consistent with the known solutions for nonreflecting wave fields in an infinite uniform duct.
Bile Duct Cancer (Cholangiocarcinoma) Symptoms, Tests, Prognosis, and Stages (PDQ®)—Patient Version
Bile duct cancer, or cholangiocarcinoma, is rare. Bile ducts are tubes that carry bile between the liver, gallbladder, and small intestine. Bile duct cancer can occur in the intrahepatic, perihilar (Klatskin tumor), or distal extrahepatic area. Learn about tests to diagnose and the stages of bile duct cancer.
2016-12-01
and spatial variations of EDH and EDS are analyzed to provide an evaporation ducting climatology for the Eastern Mediterranean Sea. The sensitivity...are analyzed to provide an evaporation ducting climatology for the Eastern Mediterranean Sea. The sensitivity of EDH and EDS to certain atmospheric...studies were conducted by K. Raptis (2012) and S. Turk (2010). Raptis (2012) examined “ climatological factors affecting EM surface ducting in the
Variable Cycle Intake for Reverse Core Engine
NASA Technical Reports Server (NTRS)
Chandler, Jesse M (Inventor); Staubach, Joseph B (Inventor); Suciu, Gabriel L (Inventor)
2016-01-01
A gas generator for a reverse core engine propulsion system has a variable cycle intake for the gas generator, which variable cycle intake includes a duct system. The duct system is configured for being selectively disposed in a first position and a second position, wherein free stream air is fed to the gas generator when in the first position, and fan stream air is fed to the gas generator when in the second position.
The solution of three-variable duct-flow equations
NASA Technical Reports Server (NTRS)
Stuart, A. R.; Hetherington, R.
1974-01-01
This paper establishes a numerical method for the solution of three-variable problems and is applied here to rotational flows through ducts of various cross sections. An iterative scheme is developed, the main feature of which is the addition of a duplicate variable to the forward component of velocity. Two forward components of velocity result from integrating two sets of first order ordinary differential equations for the streamline curvatures, in intersecting directions across the duct. Two pseudo-continuity equations are introduced with source/sink terms, whose strengths are dependent on the difference between the forward components of velocity. When convergence is obtained, the two forward components of velocity are identical, the source/sink terms are zero, and the original equations are satisfied. A computer program solves the exact equations and boundary conditions numerically. The method is economical and compares successfully with experiments on bent ducts of circular and rectangular cross section where secondary flows are caused by gradients of total pressure upstream.
Mode Propagation in Nonuniform Circular Ducts with Potential Flow
NASA Technical Reports Server (NTRS)
Cho, Y. C.; Ingard, K. U.
1982-01-01
A previously reported closed form solution is expanded to determine effects of isentropic mean flow on mode propagation in a slowly converging-diverging duct, a circular cosh duct. On the assumption of uniform steady fluid density, the mean flow increases the power transmission coefficient. The increase is directly related to the increase of the cutoff ratio at the duct throat. With the negligible transverse gradients of the steady fluid variables, the conversion from one mode to another is negligible, and the power transmission coefficient remains unchanged with the mean flow direction reversed. With a proper choice of frequency parameter, many different modes can be made subject to a single value of the power transmission loss. A systematic method to include the effects of the gradients of the steady fluid variables is also described.
Flow in out-of-plane double S-bonds
NASA Technical Reports Server (NTRS)
Schmidt, M. C.; Whitelaw, J. H.; Yianneskis, M.
1986-01-01
Developing flows in two out-of-plane double S-bend configurations have been measured by laser-Doppler anemometry. The first duct had a rectangular cross-section 40mmx40mm at the inlet and consisted of a uniform area 22.5 deg. - 22.5 deg. S-duct upstream with a 22.5 deg.- 22.5 deg. S- diffuser downstream. The second duct had a circular cross-section and consisted of a 45 deg. - 45 deg. uniform area S-duct upstream with a 22.5 deg. -22.5 deg. S-diffuser downstream. In both configurations the ratio of the mean radius of curvature to the inlet hydraulic diameter was 7.0, the exit-to-inlet area ratio of the diffusers was 1.5 and the ducts were connected so that the centerline of the S-duct lay in a plane normal to that of the S-diffuser. Streamwise and cross-stream velocity components were measured in laminar flow for the rectangular duct and in turbulent flow for both configurations; measurements of the turbulence levels, cross-correlations and wall static pressures were also made in the turbulent flow cases. Secondary flows of the first kind are present in the first S-duct and they are complemented or counteracted by the secondary flows generated by the area expansion and by the curvature of the S-diffusers downstream. Cross-stream velocities with magnitudes up to 0.19 and 0.11 of the bulk velocity were measured in the laminar and turbulent flows respectively in the rectangular duct and six cross-flow vortices were evident at the exit of the duct in both flow cases. The turbulent flow in the circular duct was qualitatively similar to that in the rectangular configuration, but the cross-stream velocities measured at the exit plane were smaller in the circular geometry. The results are presented in sufficient detail and accuracy for the assessment of numerical calculation methods and are listed in tabular form for this purpose.
Fukai, Manami; Kamisawa, Terumi; Horiguchi, Shin-Ichirou; Hishima, Tsunekazu; Kuruma, Sawako; Chiba, Kazuro; Koizumi, Satomi; Tabata, Taku; Nagao, Sayaka; Kikuyama, Masataka; Honda, Goro; Kurata, Masanao
2017-06-01
We present a resected case of annular pancreas in which Wirsung's duct encircled the duodenum and continued directly to the main pancreatic duct in the body and tail. Furthermore, Wirsung's duct coursed along the right side of the lower bile duct near the major duodenal papilla. Histologically, the islets of Langerhans in the annular pancreas were irregular in shape and were characterized by a striking abundance of pancreatic polypeptide (PP)-positive cells. The PP-rich area that encircled the duodenum was fused with the PP-poor area in the head of the pancreas. The following embryological hypothesis is proposed. The tip of the ventral pancreatic anlage adhered to the duodenal wall and stretched to form a ring during clockwise rotation. The rotation was incomplete, and the pancreatic duct did not cross over the lower bile duct. Since there was adequate ventral anlage in the lower part of the head of the pancreas, fusion between the ducts of the ventral and dorsal anlagen did not occur. The tip of the ventral anlage overgrew and adhered to the dorsal anlage, and the annular duct fused with the main duct of the dorsal anlage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. Withers, J. Cummings, B. Nigusse, E. Martin
A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity systemmore » compared to the fixed-capacity system.« less
NASA Technical Reports Server (NTRS)
Baumbick, R. J.
1974-01-01
Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.
Full-Authority Fault-Tolerant Electronic Engine Control Systems for Variable Cycle Engines.
1981-12-01
Geometry or Fuel Flow Scheduled as a Function of Engine State, i.e. FIGV = f( N1 C2 ) Closed Loop - Geometry or Fuel Flow Modulated To Maintain an Engine...Low Pressure Turbine Inlet Area (A41) Closed Loop (Integral) N2, T22 Core Stream Exhaust Nozzle Area (AJE) Closed Loop (Integral) N1 , T2 Duct Stream...to remain at the breakpoint value while low rotor speed reference ( N1 reference) is scheduled to decrease as a function of power lever angle (PLA), to
Importance of resin ducts in reducing ponderosa pine mortality from bark beetle attack.
Kane, Jeffrey M; Kolb, Thomas E
2010-11-01
The relative importance of growth and defense to tree mortality during drought and bark beetle attacks is poorly understood. We addressed this issue by comparing growth and defense characteristics between 25 pairs of ponderosa pine (Pinus ponderosa) trees that survived and trees that died from drought-associated bark beetle attacks in forests of northern Arizona, USA. The three major findings of our research were: (1) xylem resin ducts in live trees were >10% larger (diameter), >25% denser (no. of resin ducts mm(-2)), and composed >50% more area per unit ring growth than dead trees; (2) measures of defense, such as resin duct production (no. of resin ducts year(-1)) and the proportion of xylem ring area to resin ducts, not growth, were the best model parameters of ponderosa pine mortality; and (3) most correlations between annual variation in growth and resin duct characteristics were positive suggesting that conditions conducive to growth also increase resin duct production. Our results suggest that trees that survive drought and subsequent bark beetle attacks invest more carbon in resin defense than trees that die, and that carbon allocation to resin ducts is a more important determinant of tree mortality than allocation to radial growth.
Experiments in dilution jet mixing
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Srinivasan, R.; Berenfeld, A.
1983-01-01
Experimental results are presented on the mixing of a single row of jets with an isothermal mainstream in a straight duct, with flow and geometric variations typical of combustion chambers in gas turbine engines included. It is found that at a constant momentum ratio, variations in the density ratio have only a second-order effect on the profiles. A first-order approximation to the mixing of jets with a variable temperature mainstream can, it is found, be obtained by superimposing the jets-in-an-isothermal-crossflow and mainstream profiles. Another finding is that the flow area convergence, especially injection-wall convergence, significantly improves the mixing. For opposed rows of jets with the orifice cone centerlines in-line, the optimum ratio of orifice spacing to duct height is determined to be 1/2 of the optimum value for single injection at the same momentum ratio. For opposed rows of jets with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is found to be twice the optimum value for single side injection at the same momentum ratio.
Progress on Variable Cycle Engines
NASA Technical Reports Server (NTRS)
Westmoreland, J. S.; Howlett, R. A.; Lohmann, R. P.
1979-01-01
Progress in the development and future requirements of the Variable Stream Control Engine (VSCE) are presented. The two most critical components of this advanced system for future supersonic transports, the high performance duct burner for thrust augmentation, and the low jet coannular nozzle were studied. Nozzle model tests substantiated the jet noise benefit associated with the unique velocity profile possible with a coannular nozzle system on a VSCE. Additional nozzle model performance tests have established high thrust efficiency levels only at takeoff and supersonic cruise for this nozzle system. An experimental program involving both isolated component and complete engine tests has been conducted for the high performance, low emissions duct burner with good results and large scale testing of these two components is being conducted using a F100 engine as the testbed for simulating the VSCE. Future work includes application of computer programs for supersonic flow fields to coannular nozzle geometries, further experimental testing with the duct burner segment rig, and the use of the Variable Cycle Engine (VCE) Testbed Program for evaluating the VSCE duct burner and coannular nozzle technologies.
Gross, Histologic, and Computed Tomographic Anatomy of the Lacrimal System of Snakes
Souza, Nicole M.; Maggs, David J.; Park, Shin Ae; Puchalski, Sarah; Reilly, Christopher M.; Paul-Murphy, Joanne; Murphy, Christopher J.
2014-01-01
Objective To describe the lacrimal system of snakes using contrast micro-computed tomography (micro-CT) with 3-dimensional reconstruction, fluorescein passage (“Jones”) testing, histology, and gross dissection. Animals studied One Royal Python and 19 snake cadavers representing 10 species. Procedures Direct observation following injection of fluorescein into the subspectacular space, micro-CT following injection of 3 contrast agents into the subspectacular space, gross dissection following injection of latex into the subspectacular space, and histopathology. Results Injection of fluorescein confirmed patency but not course of the lacrimal duct. Barium enabled clear visualization of the lacrimal duct whereas two iodinated contrast agents proved inadequate. Collectively, micro-CT, anatomic dissections, and histology suggest tears are produced by a single, large, serous, retrobulbar gland, released into the subspectacular space via several ductules, and drained through a single punctum originating in the ventronasal subspectacular space and the lacrimal duct taking one of 3 routes of variable tortuosity before opening into the oral cavity in close association with the opening of the duct of the vomeronasal organ. Conclusions The ophidian lacrimal duct has a generally tortuous course and the details of its anatomy is species variable. The tortuous course of the duct likely predisposes snakes to duct occlusion and must be considered when planning medical and surgical interventions in snakes with pseudobuphthalmos and subspectacular abscessation. PMID:24862081
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-09-01
Forced air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as an attic or crawlspace. Any leakage of air to or from the duct system (duct leakage) in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution to this problem is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (sealed attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raisedmore » ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. This case study examines one Building America builder partner's implementation of an inexpensive, quick and effective method of building a fur-down or dropped ceiling chase.« less
Vowell, Kennison L.
1987-01-01
A closure for an inclined duct having an open upper end and defining downwardly extending passageway. The closure includes a cap for sealing engagement with the open upper end of the duct. Associated with the cap are an array of vertically aligned plug members, each of which has a cross-sectional area substantially conforming to the cross-sectional area of the passageway at least adjacent the upper end of the passageway. The plug members are interconnected in a manner to provide for free movement only in the plane in which the duct is inclined. The uppermost plug member is attached to the cap means and the cap means is in turn connected to a hoist means which is located directly over the open end of the duct.
Effect of vacuum exhaust pressure on the performance of MHD ducts at high B-field
NASA Technical Reports Server (NTRS)
Smith, J. M.; Morgan, J. L.; Wang, S.-Y.
1982-01-01
The effect of area ratio variation on the performance of a supersonic Hall MHD duct showed that for a given combustion pressure there exists an area ratio below which the power generating region of the duct is shock free and the power output increases linearly with the square of the magnetic field. For area ratios greater than this, a shock forms in the power generating region which moves upstream with increasing magnetic field strength resulting in a less rapid raise in the power output. The shock can be moved downstream by either increasing the combustion pressure or decreasing the exhaust pressure. The influence of these effects upon duct performance is presented in this paper.
Effect of vacuum exhaust pressure on the performance of MHD ducts at high B-field
NASA Technical Reports Server (NTRS)
Smith, J. M.; Morgan, J. L.; Wang, S. Y.
1982-01-01
The effect of area ratio variation on the performance of a supersonic Hall MHD duct is investigated. Results indicate that for a given combustion pressure there exists an area ratio below which the power generating region of the duct is shock free and the power output increases linearly with the square of the magnetic field. For area ratios greater than this, a shock forms in the power generating region which moves upstream with increasing magnetic field strength resulting in a less rapid raise in the power output. The shock can be moved downstream by either increasing the combustion pressure of decreasing the exhaust pressure. The influence of these effects upon duct performance is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-09-01
Forced-air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as attics or crawlspaces. Any leakage of air to or from the duct system in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceilingmore » plane (dropped ceiling or fur-down) for the duct system. In this project, Building America Partnership for Improved Residential Construction team partnered with Tommy Williams Homes to implement an inexpensive, quick, and effective method of building a fur-down chase.« less
Positive predictive value of cholescintigraphy in common bile duct obstruction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lecklitner, M.L.; Austin, A.R.; Benedetto, A.R.
1986-09-01
Technetium-99m DISIDA imaging was employed in 400 patients to differentiate obstruction of the common bile duct from medical and other surgical causes of hyperbilirubinemia. Sequential anterior images demonstrated variable degrees of liver uptake, yet there was no evidence of intrabiliary or extrabiliary radioactivity for at least 4 hr after injection in 25 patients. Twenty-three patients were surgically documented to have complete obstruction of the common bile duct. One patient had hepatitis, and another had sickle cell crisis without bile duct obstruction. The remaining patients had either partial or no obstruction of the common bile duct. We conclude that the presencemore » of liver uptake without evident biliary excretion by 4 hr on cholescintigraphy is highly sensitive and predictive of total obstruction of the common bile duct.« less
NASA Astrophysics Data System (ADS)
Hanan, Lu; Qiushi, Li; Shaobin, Li
2016-12-01
This paper presents an integrated optimization design method in which uniform design, response surface methodology and genetic algorithm are used in combination. In detail, uniform design is used to select the experimental sampling points in the experimental domain and the system performance is evaluated by means of computational fluid dynamics to construct a database. After that, response surface methodology is employed to generate a surrogate mathematical model relating the optimization objective and the design variables. Subsequently, genetic algorithm is adopted and applied to the surrogate model to acquire the optimal solution in the case of satisfying some constraints. The method has been applied to the optimization design of an axisymmetric diverging duct, dealing with three design variables including one qualitative variable and two quantitative variables. The method of modeling and optimization design performs well in improving the duct aerodynamic performance and can be also applied to wider fields of mechanical design and seen as a useful tool for engineering designers, by reducing the design time and computation consumption.
Trypsin level in gallbladder bile and ductitis and width of the cystic duct.
Vracko, J; Wiechel, K L
2000-01-01
The change from laparotomy to laparoscopy for cholecystectomy has raised the question of how to manage concomitant bile duct stones. The present-day interest--and controversy--has focused on a transcystic approach reported to be feasible in 66-96% of cases, but without explaining the necessary prerequisite: the widening of the cystic duct. The cystic duct, wide mainly in patients with bile duct stones, has been reported to be highly variable: from strictured to very wide. The present study aims at comparing the trypsin level in the gallbladder bile and the cystic duct morphology and width in patients with and without bile duct stones. A prospective series of 63 gallstone patients, 30 with and 33 without bile duct stones (controls), underwent cholecystectomy and bile duct clearance. The study includes the trypsin level in the gallbladder bile, the width and morphology of the cystic duct, and the size of the gallstones. The patients with bile duct stones had, in contrast to the controls, higher trypsin levels in the gallbladder bile (P < 0.001) and wider cystic ducts (P < 0.001) with more pronounced signs of chronic ductitis. The obtained results strongly suggest that the increased trypsin level, a sign of reflux of pancreatic juice, caused changes in the cystic duct that facilitate gallstone migration, which also ought to render a transcystic stone extraction feasible.
NASA Astrophysics Data System (ADS)
Ramadan, Omar Barka Ab
A novel low NOx conical wire-mesh duct burner was designed, built and tested in the present research. This thesis documents the design process and the in-depth evaluation of this novel duct burner for the development of a more efficient micro-cogeneration unit. This duct burner provides the thermal energy necessary to raise the microturbine exhaust gases temperature to increase the heat recovery capability. The duct burner implements both lean-premixed and surface combustion techniques to achieve low NOx and CO emissions. The design of the duct burner was supported by a qualitative flow visualization study for the duct burner premixer to provide insight into the premixer flow field (mixing process). Different premixer geometries were used to control the homogeneity of the fuel-oxidant mixture at the exit of the duct burner premixer. Laser sheet illumination (LSI) technique was used to capture images of the mixing process, for each configuration studied. A quasi-quantitative analysis technique was developed to rank the different premixer geometries in terms of mixing effectiveness. The premixer geometries that provided better mixing were selected and used for the combustion tests. The full-scale gas-fired duct burner was installed in the exhaust duct of a micro-cogeneration unit for the evaluation. Three wire-mesh burners with different pressure drops were used. Each burner has a conical shape made from FeCrAL alloy mat and was designed based on a heat release per unit area of 2500 kW/m2 and a total heat release of 240kW at 100 percent excess air. The local momentum of the gaseous mixture introduced through the wire-mesh was adjusted so that the flame stabilized outside the burner mesh (surface combustion). Cold flow tests (i.e., the duct burner was off, but the microturbine was running) were conducted to measure the effect of different duct burner geometrical parameters on flow split between the combustion zone and the bypass channel, and on pressure drop across the duct burner. A considerable amount of detailed parametric experimental data was collected to investigate the performance characteristics of the duct burner. The variables studied (firing rate, mass flow ratio, conical burner pressure drop, blockage ratio, conical burner shield length, premixer geometry and inlet conditions) were all found to play an important role on emissions (NOx and CO), overall duct burner pressure drop and flame stability. The range of firing rates at which surface combustion was maintained for the duct burner was defined by direct observation of the burner surface and monitoring of the temperature in the combustion zone. Flame images were captured for qualitative assessment. The combustion tests results presented in this thesis proved that the design procedures that were implemented to design this novel microturbine conical wire-mesh duct burner were successful. During the course of the combustion tests, the duct burner displayed stable, low emissions operation throughout the surface firing rate range of 148 kW to 328 kW (1574 kW/m 2 to 3489 kW/m2). Emissions of less than 5 ppm (corrected to 15 percent 02) for NOx and CO emissions were recorded, while the duct burner successfully raised the microturbine exhaust gases temperature from about 227°C to as high as 700°C. The overall duct burner pressure drop throughout was consistently below the design limit of 249 Pa.
Experiments and modeling of dilution jet flow fields
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1986-01-01
Experimental and analytical results of the mixing of single, double, and opposed rows of jets with an isothermal or variable-temperature main stream in a straight duct are presented. This study was performed to investigate flow and geometric variations typical of the complex, three-dimensional flow field in the dilution zone of gas-turbine-engine combustion chambers. The principal results, shown experimentally and analytically, were the following: (1) variations in orifice size and spacing can have a significant effect on the temperature profiles; (2) similar distributions can be obtained, independent of orifice diameter, if momentum-flux ratio and orifice spacing are coupled; (3) a first-order approximation of the mixing of jets with a variable-temperature main stream can be obtained by superimposing the main-stream and jets-in-an-isothermal-crossflow profiles; (4) the penetration of jets issuing mixing is slower and is asymmetric with respect to the jet centerplanes, which shift laterally with increasing downstream distance; (5) double rows of jets give temperature distributions similar to those from a single row of equally spaced, equal-area circular holes; (6) for opposed rows of jets, with the orifice centerlines in line, the optimum ratio of orifice spacing to duct height is one-half the optimum value for single-side injection at the same momentum-flux ratiol and (7) for opposed rows of jets, with the orifice centerlines staggered, the optimum ratio of orifice spacing to duct height is twice the optimum value for single-side injection at the same momentum-flux ratio.
[Value of MR imaging in the diagnosis of intraductal papillary neoplasm of the bile duct].
Song, Fengxiang; Zhou, Jun; Shi, Yuxin; Zeng, Mengsu; Zhou, Kangrong; Ding, Yuqin; Cao, Yingli; Zhou, Jianjun
2015-01-01
To analyze the value of MR imaging in diagnosis of intraductal papillary neoplasm of the bile duct (IPN-B). Fourteen patients with intraductal papillary neoplasms of the bile duct confirmed by surgical pathology were included in this study. The patients underwent MR routine plain scanning and enhancement scanning (including T1WI, T2WI with fat suppression, FALSH T1WI, and three-phase enhancement scanning), diffusion weighted imaging(DWI) and magnetic resonance cholangiopancreatography (MRCP) before operation. The imaging data were reviewed and analyzed retrospectively in comparison with the surgical and pathological results. In these patients, 7 cases had tumors located in the left lobe, 2 cases had tumors in both the left and right lobes, 2 cases in the hepatic hilum, 2 cases in the common bile duct, and 1 case in both the right lobe and the common bile duct. Solitary or multiple intraductal masses could be found in 12 cases, with 11 cases appeared as papillary masses and one case as flat mass. In the other two cases the tumor was not visible (one case had too many stones, and in another case the tumor was too small). The tumors in the 12 cases showed hypointensity on T1WI and hyperintensity on T2WI. On the dynamic contrast-enhanced MRI, 11 cases showed mild and one showed moderate enhancement in arterial phase, and all the cases showed mildly and gradually delayed enhancement. On DWI, the lesion areas showed high signal intensity in all the cases, and the ADC value of the tumor area (1.697×10(-3)mm(2)/s) was significantly lower than that of the normal bile (3.973×10(-3)mm(2)/s) (t = -10.94, P < 0.05). Twelve cases demonstrated filling defects on primary MRCP coronary thin section images. On 3D-reconstruction MRCP images, 7 cases exhibited diffuse bile duct dilatation with the tumor areas more prominent, 3 cases exhibited aneurysmal bile dilatation, while the rest 4 cases exhibited segmental or lobar bile duct dilatation ( including 2 with invisible tumors ). In the 3 cases with aneurysmal bile dilatation, the multiple directions of MRCP images helped to find the communication between the aneurysmal dilatation and the bile duct. All the cases showed significant proximal bile duct dilatation (the extent of dilatation >100%), and 9 cases also showed distal bile duct dilatation. Bile duct stones were noted in 6 cases, 4 at the tumor area, and the other 2 away from the tumor area. No adjacent tissue invasion and no distal tissue or lymph node metastasis were observed. Intraductal papillary neoplasms of the bile ducts have characteristic imaging appearances on MRI, and MRI is an important method helpful to making correct diagnosis.
Noise radiation directivity from a wind-tunnel inlet with inlet vanes and duct wall linings
NASA Technical Reports Server (NTRS)
Soderman, P. T.; Phillips, J. D.
1986-01-01
The acoustic radiation patterns from a 1/15th scale model of the Ames 80- by 120-Ft Wind Tunnel test section and inlet have been measured with a noise source installed in the test section. Data were acquired without airflow in the duct. Sound-absorbent inlet vanes oriented parallel to each other, or splayed with a variable incidence relative to the duct long axis, were evaluated along with duct wall linings. Results show that splayed vans tend to spread the sound to greater angles than those measured with the open inlet. Parallel vanes narrowed the high-frequency radiation pattern. Duct wall linings had a strong effect on acoustic directivity by attenuating wall reflections. Vane insertion loss was measured. Directivity results are compared with existing data from square ducts. Two prediction methods for duct radiation directivity are described: one is an empirical method based on the test data, and the other is a analytical method based on ray acoustics.
[Expression of calponin and P63 in human submandibular glands].
Lu, Yu-he; Gao, Yan
2007-02-01
To observe the expression of new myoepithelial cell markers calponin and P63 in human submandibular glands. Calponin and P63 antigen in routinely processed human submandibular gland tissues were immunohistochemically demonstrated by monoclonal antibodies to calponin and P63. Calponin expressed around all acinus and intercalated ducts as linear or punctuate pattern. Positive staining was also noted in peripheral area of some thin striated ducts that connect to intercalated ducts. Subulate or trigonal calponin expression was sometimes seen between the duct dells of striated ducts. P63 expressed mainly in the nucleus of the basal cells of excretory duct. Calponin is an ideal gland. P63 labels mainly the basal cells of excretory duct. marker for myoepithelial cells of human submandibular
Evaluation of a ducted-fan power plant designed for high output and good cruise fuel economy
NASA Technical Reports Server (NTRS)
Behun, M; Rom, F E; Hensley, R V
1950-01-01
Theoretical analysis of performance of a ducted-fan power plant designed both for high-output, high-altitude operation at low supersonic Mach numbers and for good fuel economy at lower fight speeds is presented. Performance of ducted fan is compared with performance (with and without tail-pipe burner) of two hypothetical turbojet engines. At maximum power, the ducted fan has propulsive thrust per unit of frontal area between thrusts obtained by turbojet engines with and without tail-pipe burners. At cruise, the ducted fan obtains lowest thrust specific fuel consumption. For equal maximum thrusts, the ducted fan obtains cruising flight duration and range appreciably greater than turbojet engines.
Observed characteristics of atmospheric ducts over the South China Sea in autumn
NASA Astrophysics Data System (ADS)
Cheng, Yinhe; Zhou, Shengqi; Wang, Dongxiao; Lu, Yuanzheng; Huang, Ke; Yao, Jinglong; You, Xiaobao
2016-05-01
The observed characteristics of lower atmospheric ducts over the South China Sea (SCS) were analyzed based on Global Position Systerm (GPS) radiosonde data collected four times daily during autumn open cruises from 2006 to 2012. Duct occurrence, thickness, and strength over the SCS were about 40%, 150-m thick, and 8 M units, respectively, which were larger than during the summer monsoon period. Most ducts occurred at heights <1 500 m and these ducts easily trap electromagnetic wave clusters with wavelengths <2 m. Diurnal variation of the SCS ducts appeared evident. They occurred more often at midnight at higher altitudes (about 1 100 m), with a thickest layer of about 145 m and less frequently during the evening at lower altitudes (about 800 m), with a thinnest layer of about 125 m. Moreover, ducts during the daytime at a mean height of about 900 m, with the greatest strength of about 10 M units. Furthermore, all duct variables observed over the SCS in autumn decreased from north to south. These findings are useful not only in the design of radar and communication systems, but also for evaluating possible effects of anomalous propagation on meteorological radar and military applications.
Lapp, Robert T; Wolf, J Stuart; Faerber, Gary J; Roberts, William W; McCarthy, Sean T; Anderson, Michelle A; Wamsteker, Erik-Jan; Elta, Grace H; Scheiman, James M; Kwon, Richard S
2016-09-01
The need for endoscopic therapy before extracorporeal shock wave lithotripsy (SWL) to facilitate pancreatic duct stone removal is unclear. Predictive factors associated with successful fragmentation and subsequent complete duct clearance are variable. We hypothesize pancreatic duct strictures and large stones, but not pre-SWL endotherapy, correlate with successful fragmentation and complete duct clearance. A retrospective cohort study of patients with pancreaticolithiasis who underwent SWL and endoscopic retrograde cholangiopancreatography between January 2009 and June 2014 was evaluated. Thirty-seven patients were treated. Technical success (TS) of fragmentation was achieved in 22 patients (60%). Technical success was associated with fewer stones and SWL sessions and smaller stone and duct size. By multivariate logistic regression, only duct dilation was associated with TS. Endoscopic success of complete duct clearance was achieved in 29 patients (80%). Endoscopic success was more frequent with stones 12 mm or less and with successful TS. By multivariate logistic regression, stones greater than 12 mm were associated with endoscopic failure. Pre-SWL endotherapy does not affect stone fragmentation. Patients with a dilated duct (>8 mm) and pancreatic stones 12 mm or greater were associated with unsuccessful TS and endoscopic success, respectively, and may benefit from early referral for surgical decompression.
Duct wall impedance control as an advanced concept for acoustic impression
NASA Technical Reports Server (NTRS)
Dean, P. D.; Tester, B. J.
1975-01-01
Models and tests on an acoustic duct liner system which has the property of controlled-variable acoustic impedance are described. This is achieved by a novel concept which uses the effect of steady air flow through a multi-layer, locally reacting, resonant-cavity absorber. The scope of this work was limited to a 'proof of concept.' The test of the concept was implemented by means of a small-scale, square-section flow duct facility designed specifically for acoustic measurements, with one side of the duct acoustically lined. The test liners were designed with the aid of previously established duct acoustic theory and a semi-empirical impedance model of the liner system. Over the limited range tested, the liner behaved primarily as predicted, exhibiting significant changes in resistance and reactance, thus providing the necessary concept validation.
The vomeronasal system of the mink, Mustela vison. I. The vomeronasal organ.
Salazar, I; Cifuentes, J M; Quinteiro, P S; Caballero, G
1994-01-01
The vomeronasal organ (VNO) of the mink is restricted to the area of the Fissura palatina and thus always topographically related to the Ductus incisivus (DI). The VNO and DI have also a functional relation because the vomeronasal duct ends in the incisive duct. On the other hand, as the DI has its mouth in the Papilla incisiva there is a communication between the VNO and the oral cavity. The vomeronasal cartilage, approximately in 1/6 of its length, wraps completely the parenchyma of the VNO whose main structure is the vomeronasal duct, with two different epithelia: sensory receptor in the medial wall, and respiratory in the lateral one. Nevertheless the variations of epithelia belong to the segment of the duct because in its rostral and caudal parts the medial and lateral epithelia are very similar. Branches and tubular PAS positive glands stand out in three points: superior, inferior and medial areas of the vomeronasal duct in which they end. An important number of vessels, mainly veins of different diameter, are located around the duct, while the nervous fibers are close to the medial wall of the duct and very easy to identify in the caudal third of the organ. Two immunohistochemical techniques were used to identify the nerve fibers and the receptor cells.
A finite element simulation of sound attenuation in a finite duct with a peripherally variable liner
NASA Technical Reports Server (NTRS)
Watson, W. R.
1977-01-01
Using multimodal analysis, a variational finite element method is presented for analyzing sound attenuation in a three-dimensional finite duct with a peripherally variable liner in the absence of flow. A rectangular element, with cubic shaped functions, is employed. Once a small portion of a peripheral liner is removed, the attenuation rate near the frequency where maximum attenuation occurs drops significantly. The positioning of the liner segments affects the attenuation characteristics of the liner. Effects of the duct termination are important in the low frequency ranges. The main effect of peripheral variation of the liner is a broadening of the attenuation characteristics in the midfrequency range. Because of matrix size limitations of the presently available computer program, the eigenvalue equations should be solved out of core in order to handle realistic sources.
Advanced Noise Control Fan: A 20-Year Retrospective
NASA Technical Reports Server (NTRS)
Sutliff, Dan
2016-01-01
The ANCF test bed is used for evaluating fan noise reduction concepts, developing noise measurement technologies, and providing a database for Aero-acoustic code development. Rig Capabilities: 4 foot 16 bladed rotor @ 2500 rpm, Auxiliary air delivery system (3 lbm/sec @ 6/12 psi), Variable configuration (rotor pitch angle, stator count/position, duct length), synthetic acoustic noise generation (tone/broadband). Measurement Capabilities: 112 channels dynamic data system, Unique rotating rake mode measuremen, Farfield (variable radius), Duct wall microphones, Stator vane microphones, Two component CTA w/ traversing, ESP for static pressures.
NASA Technical Reports Server (NTRS)
Lohmann, R. A.; Riecke, G. T.
1977-01-01
An analytical screening study was conducted to identify duct burner concepts capable of providing low emissions and high performance in advanced supersonic engines. Duct burner configurations ranging from current augmenter technology to advanced concepts such as premix-prevaporized burners were defined. Aerothermal and mechanical design studies provided the basis for screening these configurations using the criteria of emissions, performance, engine compatibility, cost, weight and relative risk. Technology levels derived from recently defined experimental low emissions main burners are required to achieve both low emissions and high performance goals. A configuration based on the Vorbix (Vortex burning and mixing) combustor concept was analytically determined to meet the performance goals and is consistent with the fan duct envelope of a variable cycle engine. The duct burner configuration has a moderate risk level compatible with the schedule of anticipated experimental programs.
IET exhaust gas duct, system layout, plan, and section. shows ...
IET exhaust gas duct, system layout, plan, and section. shows mounting brackets, concrete braces, divided portion of duct, other details. Ralph M. Parsons 902-5-ANP-712-S 429. Date: May 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0712-60-693-106980 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
1973-10-01
turbofan engine shutoff scheme, the ram duct flow conditions, and the Ian duct shutoff vane area transi- tion schedule. This loss will be...airflow. The performance of the turbofan is neglected until the main engine burner is ignited. At that time it is assumed that the turbo - fan...B. Transient Operation . . .. TRANSIENT TRANSITION TEST CASES A. Turbofan to Ramjet B. Ramjet to Turbo fan CONCLUSIONS AND RECOMMENDATIONS
The vomeronasal organ of the cat.
Salazar, I; Sanchez Quinteiro, P; Cifuentes, J M; Garcia Caballero, T
1996-01-01
The vomeronasal organ of the cat was studied macroscopically, by light microscopy and by immunohistochemical techniques. Special attention was paid to the general distribution of the various soft tissue components of this organ (duct, glands, connective tissue, blood vessels and nerves.) Examination of series of transverse sections showed that the wall of the vomeronasal duct bears 44 different types of epithelium: simple columnar in the caudal part of the duct, respiratory and receptor respectively on the lateral and medial walls of the middle part of the duct, and stratified squamous rostrally. The pattern of distribution of other soft tissue components was closely associated with that of epithelium types. In areas where the duct wall was lined with receptor epithelium, nerves and connective tissue were present between the epithelium and the medial sheet of the vomeronasal cartilage. Most glands and blood vessels were located lateral to those areas of the duct wall lined with respiratory epithelium. Numerous basal cells were present in the sensory epithelium. Understanding of the distribution of the soft tissue components of this organ may shed light on its function. Images Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Figs. 13-14 PMID:8621344
Duct modes damping through an adjustable electroacoustic liner under grazing incidence
NASA Astrophysics Data System (ADS)
Boulandet, R.; Lissek, H.; Karkar, S.; Collet, M.; Matten, G.; Ouisse, M.; Versaevel, M.
2018-07-01
This paper deals with active sound attenuation in lined ducts with flow and its application to duct modes damping in aircraft engine nacelles. It presents an active lining concept based on an arrangement of electroacoustic absorbers flush mounted in the duct wall. Such feedback-controlled loudspeaker membranes are used to achieve locally reacting impedances with adjustable resistance and reactance. A broadband impedance model is formulated from the loudspeaker parameters and a design procedure is proposed to achieve specified acoustic resistances and reactances. The performance is studied for multimodal excitation by simulation using the finite element method and the results are compared to measurements made in a flow duct facility. This electroacoustic liner has an attenuation potential comparable to that of a conventional passive liner, but also offers greater flexibility to achieve the target acoustic impedance in the low frequencies. In addition, it is adaptive in real time to track variable engine speeds. It is shown with the liner prototype that the duct modes can be attenuated over a bandwidth of two octaves around the resonance frequency of the loudspeakers.
Loomba, Rohit S; Frommelt, Michele; Moe, David; Shillingford, Amanda J
2015-02-01
Agenesis of the venous duct is a rare congenital anomaly resulting in abnormal drainage of the umbilical vein into the foetal venous circulation. The clinical presentation and prognosis is variable, and may depend on the specific drainage pathways of the umbilical vein. We present two foetuses with agenesis of the venous duct, both associated with a postnatal portosystemic shunt, but with markedly different postnatal clinical courses. We also review all previously reported cases to better characterise this foetal disorder and the prognosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.; Walker, Iain S.
Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with naturalmore » rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected weekly. The baking test specimens were visually inspected weekly, and the durability was judged by the observed deterioration in terms of brittleness, cracking, flaking and blistering (the terminology used in the UL 181B-FX test procedure).« less
Navier-Stokes analysis and experimental data comparison of compressible flow within ducts
NASA Technical Reports Server (NTRS)
Harloff, G. J.; Reichert, B. A.; Sirbaugh, J. R.; Wellborn, S. R.
1992-01-01
Many aircraft employ ducts with centerline curvature or changing cross-sectional shape to join the engine with inlet and exhaust components. S-ducts convey air to the engine compressor from the intake and often decelerate the flow to achieve an acceptable Mach number at the engine compressor by increasing the cross-sectional area downstream. Circular-to-rectangular transition ducts are used on aircraft with rectangular exhaust nozzles to connect the engine and nozzle. To achieve maximum engine performance, the ducts should minimize flow total pressure loss and total pressure distortion at the duct exit. Changes in the curvature of the duct centerline or the duct cross-sectional shape give rise to streamline curvature which causes cross stream pressure gradients. Secondary flows can be caused by deflection of the transverse vorticity component of the boundary layer. This vortex tilting results in counter-rotating vortices. Additionally, the adverse streamwise pressure gradient caused by increasing cross-sectional area can lead to flow separation. Vortex pairs have been observed in the exit planes of both duct types. These vortices are due to secondary flows induced by pressure gradients resulting from streamline curvature. Regions of low total pressure are produced when the vortices convect boundary layer fluid into the main flow. The purpose of the present study is to predict the measured flow field in a diffusing S-duct and a circular-to-rectangular transition duct with a full Navier-Stokes computer program, PARC3D, and to compare the numerical predictions with new detailed experimental measurements. The work was undertaken to extend previous studies and to provide additional CFD validation data needed to help model flows with strong secondary flow and boundary layer separation. The S-duct computation extends the study of Smith et al, and Harloff et al, which concluded that the computation might be improved by using a finer grid and more advanced turbulence models. The present study compares results for both the Baldwin-Lomas and k-epsilon turbulence models and is conducted with a refined grid. For the transition duct, two inlet conditions were considered, the first with straight flow and the second with swirling flow. The first case permits examination of the effects of the geometric transition on the flow field, while the second case includes the rotational flow effect characteristic of a gas turbine engine.
Progress with variable cycle engines
NASA Technical Reports Server (NTRS)
Westmoreland, J. S.
1980-01-01
The evaluation of components of an advanced propulsion system for a future supersonic cruise vehicle is discussed. These components, a high performance duct burner for thrust augmentation and a low jet noise coannular exhaust nozzle, are part of the variable stream control engine. An experimental test program involving both isolated component and complete engine tests was conducted for the high performance, low emissions duct burner with excellent results. Nozzle model tests were completed which substantiate the inherent jet noise benefit associated with the unique velocity profile possible of a coannular exhaust nozzle system on a variable stream control engine. Additional nozzle model performance tests have established high thrust efficiency levels at takeoff and supersonic cruise for this nozzle system. Large scale testing of these two critical components is conducted using an F100 engine as the testbed for simulating the variable stream control engine.
Agenesis of the gallbladder with hypoplastic cystic duct diagnosed at laparoscopy.
Kwon, A-Hon; Yanagimoto, Hiroaki; Matsui, Yoichi; Imamura, Atsushi
2006-08-01
An 86-year-old man was admitted to our department with complaints of intermittent upper abdominal pain. Ultrasonography of the abdomen showed dilated extrahepatic bile ducts containing stones; however, the gallbladder was not clearly identified. Magnetic resonance cholangiopancreatography showed dilated extrahepatic ducts and choledocholithiasis without gallbladder visualization. The stone extraction was performed with endoscopic sphincterotomy. Three-dimensional images using spiral-computed tomography after intravenous-infusion cholangiography clearly demonstrated an obstruction of the cystic duct. The patient was scheduled for laparoscopic cholecystectomy. At laparoscopy, the gallbladder fossa was not identified on the undersurface of the liver. Despite a thorough examination of the intrahepatic (left-sided within the lesser omentum), retroperitoneal, retrohepatic (within the falciform ligament), retroduodenal, and retropancreatic areas using laparoscopic ultrasonography, the gallbladder was not found. After careful dissection of the hepatoduodenal ligament, the dilated extrahepatic bile duct and a 1-cm length of hypoplastic cystic duct were found. Gallbladder agenesis is usually accompanied by the lack of the cystic duct. The present case is the third report of gallbladder agenesis with a patent or hypoplastic cystic duct.
Energy efficient engine: Turbine transition duct model technology report
NASA Technical Reports Server (NTRS)
Leach, K.; Thurlin, R.
1982-01-01
The Low-Pressure Turbine Transition Duct Model Technology Program was directed toward substantiating the aerodynamic definition of a turbine transition duct for the Energy Efficient Engine. This effort was successful in demonstrating an aerodynamically viable compact duct geometry and the performance benefits associated with a low camber low-pressure turbine inlet guide vane. The transition duct design for the flight propulsion system was tested and the pressure loss goal of 0.7 percent was verified. Also, strut fairing pressure distributions, as well as wall pressure coefficients, were in close agreement with analytical predictions. Duct modifications for the integrated core/low spool were also evaluated. The total pressure loss was 1.59 percent. Although the increase in exit area in this design produced higher wall loadings, reflecting a more aggressive aerodynamic design, pressure profiles showed no evidence of flow separation. Overall, the results acquired have provided pertinent design and diagnostic information for the design of a turbine transition duct for both the flight propulsion system and the integrated core/low spool.
Acoustic theory of axisymmetric multisectioned ducts. [reduction of turbofan engine noise
NASA Technical Reports Server (NTRS)
Zorumski, W. E.
1974-01-01
Equations are developed for the acoustic field in a duct system which is made up of a number of connected circular and annular ducts. These equations are suitable for finding the acoustic field inside of and radiated from an aircraft turbofan engine. Acoustic modes are used as generalized coordinates in order to develop a set of matrix equations for the acoustic field. Equations for these modes are given for circular and annular ducts with uniform flow. Modal source equations are derived for point acoustic sources. General equations for mode transmission and reflection are developed and detailed equations are derived for ducts with multiple sections of acoustic treatment and for ducts with circumferential splitter rings. The general theory is applied to the special case of a uniform area circular duct with multisection liners and it is shown that the mode reflection effects are proportional to differences of the acoustic admittances of adjacent liners. A numerical example is given which shows that multisection liners may provide greater noise suppression than uniform liners.
Turboprop engine and method of operating the same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klees, G.W.; Johnson, P.E.
1986-02-11
This patent describes a turboprop engine consisting of: 1.) A compressor; 2.) A turbine; 3.) A combustion section; 4.) A variable pitch propeller; 5.) A speed reducing transmission; 6.) An air inlet; 7.) An air inlet bypass; 8.) An air outlet bypass duct; 9.) A flow control operatively positioned to receive air flow from the air inlet bypass and air flow from the low pressure compressor component. To direct the air flow to the air outlet bypass duct, and the air flow to the high pressure compressor component, the flow control has a first position where the air flow ismore » from. The high and low pressure compressor components and is directed to the air outlet bypass duct. The flow control has a second position for the air flow from the air inlet bypass duct to the air outlet bypass duct and air from the low pressure compressor component is directed to the high pressure compressor component. A method of operating a turboprop engine.« less
User's manual for Axisymmetric Diffuser Duct (ADD) code. Volume 1: General ADD code description
NASA Technical Reports Server (NTRS)
Anderson, O. L.; Hankins, G. B., Jr.; Edwards, D. E.
1982-01-01
This User's Manual contains a complete description of the computer codes known as the AXISYMMETRIC DIFFUSER DUCT code or ADD code. It includes a list of references which describe the formulation of the ADD code and comparisons of calculation with experimental flows. The input/output and general use of the code is described in the first volume. The second volume contains a detailed description of the code including the global structure of the code, list of FORTRAN variables, and descriptions of the subroutines. The third volume contains a detailed description of the CODUCT code which generates coordinate systems for arbitrary axisymmetric ducts.
Wind wheel electric power generator
NASA Technical Reports Server (NTRS)
Kaufman, J. W. (Inventor)
1980-01-01
Wind wheel electric power generator apparatus includes a housing rotatably mounted upon a vertical support column. Primary and auxiliary funnel-type, venturi ducts are fixed onto the housing for capturing wind currents and conducting to a bladed wheel adapted to be operatively connected with the generator apparatus. Additional air flows are also conducted onto the bladed wheel; all of the air flows positively effecting rotation of the wheel in a cumulative manner. The auxiliary ducts are disposed at an acute angle with respect to the longitudinal axis of the housing, and this feature, together with the rotatability of the housing and the ducts, permits capture of wind currents within a variable directional range.
DOE Office of Scientific and Technical Information (OSTI.GOV)
A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity systemmore » compared to the fixed-capacity system.« less
Measured Performance of a Varied Airflow Small-Diameter Duct System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
2017-03-01
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Measured Performance of a Varied Airflow Small-Diameter Duct System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Turbofan gas turbine engine with variable fan outlet guide vanes
NASA Technical Reports Server (NTRS)
Wood, Peter John (Inventor); LaChapelle, Donald George (Inventor); Grant, Carl (Inventor); Zenon, Ruby Lasandra (Inventor); Mielke, Mark Joseph (Inventor)
2010-01-01
A turbofan gas turbine engine includes a forward fan section with a row of fan rotor blades, a core engine, and a fan bypass duct downstream of the forward fan section and radially outwardly of the core engine. The forward fan section has only a single stage of variable fan guide vanes which are variable fan outlet guide vanes downstream of the forward fan rotor blades. An exemplary embodiment of the engine includes an afterburner downstream of the fan bypass duct between the core engine and an exhaust nozzle. The variable fan outlet guide vanes are operable to pivot from a nominal OGV position at take-off to an open OGV position at a high flight Mach Number which may be in a range of between about 2.5-4+. Struts extend radially across a radially inwardly curved portion of a flowpath of the engine between the forward fan section and the core engine.
Muraki, Takashi; Kim, Grace E; Reid, Michelle D; Mittal, Pardeep; Bedolla, Gabriela; Memis, Bahar; Pehlivanoglu, Burcin; Freedman, Alexa; Erbarut Seven, Ipek; Choi, Hyejeong; Kooby, David; Maithel, Shishir K; Sarmiento, Juan M; Krasinskas, Alyssa; Adsay, Volkan
2017-10-01
Clinicopathologic characteristics of paraduodenal (groove) pancreatitis (PDP) remain to be fully unraveled. In this study, 47 PDPs with preoperative enhanced images available were subjected to detailed comparative analysis in conjunction with pathologic findings. PDP were predominantly in males (3:1) with a mean age of 50 years, and 60% had a preoperative diagnosis of cancer. Mean lesional size was 3.1 cm. Three distinct subtypes were identified by imaging. Solid-tumoral (type-1) with groove-predominant (type-1A, 36%) forming a distinct solid band between the duodenum and pancreas often with histologic microabscesses (69% vs. 33% in others), and pancreas-involving (type-1B, 19%) forming a pseudotumoral mass spanning into the head-groove area, always diagnosed preoperatively as "cancer," but often lacked parenchymal atrophy of the body (44% vs. 92%). Cyst-forming (type-2) had groove-predominant (type-2A, 15%), often accompanied by Brunner gland hyperplasia, and pancreas-predominant (type-2B, 15%) were in younger (mean: 44 y) females (57% vs. 18%) and had less alcohol/tobacco abuse (50/33% vs. 81/69%). Ill-defined (type-3; 15%) often had main pancreatic duct dilatation (mean: 5.6 vs. 2.8 mm). The capricious presentations of PDP could be attributed to variable effects of different mechanistic and precipitative etiopathogenetic factors such as disturbed accessory duct outflow (dilated Santorini duct, 87%), aggravated by alcohol (77%) with superimposed stasis in the main ampulla (previous cholecystectomy, 47%; choledocholithiasis, 9%), strictured Wirsung duct (68%), and some likely exacerbated by ischemia (hypertension [59%], tobacco abuse [64%], arteriosclerosis in the tissue [23%]). In conclusion, our study identified 3 distinct types of PDP and each may reflect different pathogenetic contributing factors.
NASA Astrophysics Data System (ADS)
Fei, Jianfang; Ding, Juli; Huang, Xiaogang; Cheng, Xiaoping; Hu, Xiaohua
2013-06-01
The Weather Research and Forecasting model version 3.2 (WRF v3.2) was used with the bogus data assimilation (BDA) scheme and sea spray parameterization (SSP), and experiments were conducted to assess the impacts of the BDA and SSP on prediction of the typhoon ducting process induced by Typhoon Mindule (2004). The global positioning system (GPS) dropsonde observations were used for comparison. The results show that typhoon ducts are likely to form in every direction around the typhoon center, with the main type of ducts being elevated duct. With the BDA scheme included in the model initialization, the model has a better performance in predicting the existence, distribution, and strength of typhoon ducts. This improvement is attributed to the positive effect of the BDA scheme on the typhoon's ambient boundary layer structure. Sea spray affects typhoon ducts mainly by changing the latent heat (LH) flux at the air-sea interface beyond 270 km from the typhoon center. The strength of the typhoon duct is enhanced when the boundary layer under this duct is cooled and moistened by the sea spray; otherwise, the typhoon duct is weakened. The sea spray induced changes in the air-sea sensible heat (SH) flux and LH flux are concentrated in the maximum wind speed area near the typhoon center, and the changes are significantly weakened with the increase of the radial range.
Sound attenuation of fiberglass lined ventilation ducts
NASA Astrophysics Data System (ADS)
Albright, Jacob
Sound attenuation is a crucial part of designing any HVAC system. Most ventilation systems are designed to be in areas occupied by one or more persons. If these systems do not adequately attenuate the sound of the supply fan, compressor, or any other source of sound, the affected area could be subject to an array of problems ranging from an annoying hum to a deafening howl. The goals of this project are to quantify the sound attenuation properties of fiberglass duct liner and to perform a regression analysis to develop equations to predict insertion loss values for both rectangular and round duct liners. The first goal was accomplished via insertion loss testing. The tests performed conformed to the ASTM E477 standard. Using the insertion loss test data, regression equations were developed to predict insertion loss values for rectangular ducts ranging in size from 12-in x 18-in to 48-in x 48-in in lengths ranging from 3ft to 30ft. Regression equations were also developed to predict insertion loss values for round ducts ranging in diameters from 12-in to 48-in in lengths ranging from 3ft to 30ft.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Liscinsky, D. S.; Bain, D. B.
1999-01-01
This paper summarizes experimental and computational results on the mixing of opposed rows of jets with a confined subsonic crossflow in rectangular ducts. The studies from which these results were excerpted investigated flow and geometric variations typical of the complex three-dimensional flowfield in the combustion chambers in gas turbine engines. The principal observation was that the momentum-flux ratio, J, and the orifice spacing, S/H, were the most significant flow and geometric variables. Jet penetration was critical, and penetration decreased as either momentum-flux ratio or orifice spacing decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the orifice spacing was inversely proportional to the square-root of the momentum-flux ratio. It was also seen that planar averages must be considered in context with the distributions. Note also that the mass-flow ratios and the orifices investigated were often very large (jet-to-mainstream mass-flow ratio > 1 and the ratio of orifices-area-to-mainstream- cross-sectional-area up to 0.5, respectively), and the axial planes of interest were often just downstream of the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations.
NASA Technical Reports Server (NTRS)
Holdeman, James D.; Liscinsky, David S.; Bain, Daniel B.
1997-01-01
This paper summarizes experimental and computational results on the mixing of opposed rows of jets with a confined subsonic crossflow in rectangular ducts. The studies from which these results were excerpted investigated flow and geometric variations typical of the complex 3-D flowfield in the combustion chambers in gas turbine engines. The principal observation was that the momentum-flux ratio, J, and the orifice spacing, S/H, were the most significant flow and geometric variables. Jet penetration was critical, and penetration decreased as either momentum-flux ratio or orifice spacing decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the orifice spacing was inversely proportional to the square-root of the momentum-flux ratio. It was also seen that planar averages must be considered in context with the distributions. Note also that the mass-flow ratios and the offices investigated were often very large (jet-to-mainstream mass-flow ratio greater than 1 and the ratio of orifices-area-to-mainstream-cross-sectional-area up to 0.5 respectively), and the axial planes of interest were often just downstream of the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations.
Acoustics flow analysis in circular duct using sound intensity and dynamic mode decomposition
NASA Astrophysics Data System (ADS)
Weyna, S.
2014-08-01
Sound intensity generation in hard-walled duct with acoustic flow (no mean-flow) is treated experimentally and shown graphically. In paper, numerous methods of visualization illustrating the vortex flow (2D, 3D) can graphically explain diffraction and scattering phenomena occurring inside the duct and around open end area. Sound intensity investigation in annular duct gives a physical picture of sound waves in any duct mode. In the paper, modal energy analysis are discussed with particular reference to acoustics acoustic orthogonal decomposition (AOD). The image of sound intensity fields before and above "cut-off" frequency region are found to compare acoustic modes which might resonate in duct. The experimental results show also the effects of axial and swirling flow. However acoustic field is extremely complicated, because pressures in non-propagating (cut-off) modes cooperate with the particle velocities in propagating modes, and vice versa. Measurement in cylindrical duct demonstrates also the cut-off phenomenon and the effect of reflection from open end. The aim of experimental study was to obtain information on low Mach number flows in ducts in order to improve physical understanding and validate theoretical CFD and CAA models that still may be improved.
Variable flow gas turbine engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stroem, S.
1986-11-25
This patent describes a variable flow gas turbine engine of the type having a combustor for generating combustion gases and a turbine rotor for receiving and expanding the hot combustion gases, comprising: duct means for defining a channel for directing the flow of combustion gases from the combustor to the rotor; vane means in the channel forming at least one throat; means for varying the effective flow area for combustion gases flowing through the throat and impinging on the rotor. The varying means includes winglet means fixedly mounted in the throat for separating the gases flowing through the throat intomore » first and second streams; and means for injecting high pressure fluid into the throat for varying the flow of combustion gases in one of the streams.« less
Meyer, K M; Calfee, M W; Wood, J P; Mickelsen, L; Attwood, B; Clayton, M; Touati, A; Delafield, R
2014-03-01
To evaluate hydrogen peroxide vapour (H2 O2 ) for its ability to inactivate Bacillus spores within a laboratory-scale heating, ventilation and air-conditioning (HVAC) duct system. Experiments were conducted in a closed-loop duct system, constructed of either internally lined or unlined galvanized metal. Bacterial spores were aerosol-deposited onto 18-mm-diameter test material coupons and strategically placed at several locations within the duct environment. Various concentrations of H2 O2 and exposure times were evaluated to determine the sporicidal efficacy and minimum exposure needed for decontamination. For the unlined duct, high variability was observed in the recovery of spores between sample locations, likely due to complex, unpredictable flow patterns within the ducts. In comparison, the lined duct exhibited a significant desorption of the H2 O2 following the fumigant dwell period and thus resulted in complete decontamination at all sampling locations. These findings suggest that decontamination of Bacillus spore-contaminated unlined HVAC ducts by hydrogen peroxide fumigation may require more stringent conditions (higher concentrations, longer dwell duration) than internally insulated ductwork. These data may help emergency responders when developing remediation plans during building decontamination. © 2013 The Society for Applied Microbiology This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Conceptual design study of advanced acoustic-composite nacelles
NASA Technical Reports Server (NTRS)
Nordstrom, K. E.; Marsh, A. H.; Sargisson, D. F.
1975-01-01
Conceptual studies were conducted to assess the impact of incorporating advanced technologies in the nacelles of a current wide-bodied transport and an advanced technology transport. The improvement possible in the areas of fuel consumption, flyover noise levels, airplane weight, manufacturing costs, and airplane operating cost were evaluated for short and long-duct nacelles. Use of composite structures for acoustic duct linings in the fan inlet and exhaust ducts was considered as well as for other nacelle components. For the wide-bodied transport, the use of a long-duct nacelle with an internal mixer nozzle in the primary exhaust showed significant improvement in installed specific fuel consumption and airplane direct operating costs compared to the current short-duct nacelle. The long-duct mixed-flow nacelle is expected to achieve significant reductions in jet noise during takeoff and in turbo-machinery noise during landing approach. Recommendations were made of the technology development needed to achieve the potential fuel conservation and noise reduction benefits.
Biliary tract enhancement in gadoxetic acid-enhanced MRI correlates with liver function biomarkers.
Noda, Yoshifumi; Goshima, Satoshi; Kajita, Kimihiro; Kawada, Hiroshi; Kawai, Nobuyuki; Koyasu, Hiromi; Matsuo, Masayuki; Bae, Kyongtae T
2016-11-01
To evaluate the association between gadoxetic-acid-enhanced magnetic resonance (MR) imaging measurements and laboratory and clinical biomarkers of liver function and fibrosis. One hundred thirty nine consecutive patients with suspected liver disease or liver tumor underwent gadoxetic-acid-enhanced MR imaging. MR imaging measurements during the hepatobiliary phase included biliary tract structure-to-muscle signal intensity ratio (SIR). These measurements were compared with Child-Pugh classification, end-stage liver disease (MELD) score, and aspartate aminotransferase-to-platelet ratio index (APRI). The SIRs of cystic duct and common bile duct were significantly correlated with Child-Pugh classification (P=0.012 for cystic duct and P<0.0001 for common bile duct), MELD score (P=0.0016 and P=0.0033), and APRI (P=0.0022 and P=0.0015). The sensitivity, specificity, and area under the receiver-operating-characteristic curve were: (74%, 88%, 0.86) with the SIR of common bile duct for the detection of patients with Child-Pugh class B or C; (100%, 87%, 0.94) with the SIR of cystic duct for MELD score (>10); (65%, 76%, 0.70) with the SIR of common bile duct for APRI (>1.5). Gadoxetic-acid contrast enhancement of cystic duct and common bile duct could be used as biomarkers to assess liver function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Secondary flow in turbulent ducts with increasing aspect ratio
NASA Astrophysics Data System (ADS)
Vinuesa, R.; Schlatter, P.; Nagib, H. M.
2018-05-01
Direct numerical simulations of turbulent duct flows with aspect ratios 1, 3, 5, 7, 10, and 14.4 at a center-plane friction Reynolds number Reτ,c≃180 , and aspect ratios 1 and 3 at Reτ,c≃360 , were carried out with the spectral-element code nek5000. The aim of these simulations is to gain insight into the kinematics and dynamics of Prandtl's secondary flow of the second kind and its impact on the flow physics of wall-bounded turbulence. The secondary flow is characterized in terms of the cross-plane component of the mean kinetic energy, and its variation in the spanwise direction of the flow. Our results show that averaging times of around 3000 convective time units (based on duct half-height h ) are required to reach a converged state of the secondary flow, which extends up to a spanwise distance of around ≃5 h measured from the side walls. We also show that if the duct is not wide enough to accommodate the whole extent of the secondary flow, then its structure is modified as reflected through a different spanwise distribution of energy. Another confirmation of the extent of the secondary flow is the decay rate of kinetic energy of any remnant secondary motions for zc/h >5 (where zc is the spanwise distance from the corner) in aspect ratios 7, 10, and 14.4, which exhibits a decreasing level of energy with increasing averaging time ta, and in its rapid rate of decay given by ˜ta-1 . This is the same rate of decay observed in a spanwise-periodic channel simulation, which suggests that at the core, the kinetic energy of the secondary flow integrated over the cross-sectional area,
Flow in curved ducts of varying cross-section
NASA Astrophysics Data System (ADS)
Sotiropoulos, F.; Patel, V. C.
1992-07-01
Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.
Intraductal papillary neoplasm of the bile duct: a case report.
Peeters, Karen; Delvaux, Peter; Huysentruyt, Frederik
2017-08-01
Intraductal papillary neoplasm of the bile duct (IPNB) is a rare variant of bile duct tumors, characterized by papillary growth within the bile duct lumen and is regarded as a biliary counterpart of intraductal papillary mucinous neoplasm (IPMN) of the pancreas. IPNBs are mainly found in patients from Far Eastern areas, where hepatolithiasis and clonorchiasis are endemic. The Western experience, however, remains limited. In this article, we report a 56-year-old man, referred to our hospital because of deranged liver function tests. Further imaging modalities showed a cystic lesion of 9 cm diameter, arising from the left hepatic duct. Inlying was a heterogeneous, lobulated mass. The patient underwent a left hemihepatectomy and adjuvant chemotherapy. Despite recent advanced technologies, diagnosis of IPNB is still challenging, especially in western countries due to its rarity. Early identification and resection of lesions, even in asymptomatic or minimally symptomatic patients, are however important prognostic factors.
NASA Technical Reports Server (NTRS)
Roman, W. C.
1979-01-01
The feasibility of employing a flowing, high-temperature, pure fluorine/UF6 regeneration system to efficiently convert a large fraction of the effluent plasma exhaust back to pure UF6 was demonstrated. The custom built T.O.F. mass spectrometer sampling system permitted on-line measurements of the UF6 concentration at different locations in the exhaust system. Negligible amounts ( 100 ppm) of UF6 were detected in the axial bypass exhaust duct and the exhaust ducts downstream of the cryogenic trap system used to collect the UF6, thus verifying the overall system efficiency over a range of operating conditions. Use of a porous Monel duct as part of the exhaust duct system, including provision for injection of pure fluorine, provided a viable technique to eliminate uranium compound residue on the inside surface of the exhaust ducts. Typical uranium compound mass deposition per unit area of duct was 2 micron g/sq cm. This porous duct technique is directly applicable to future uranium compound transfer exhaust systems. Throughout these experiments, additional basic data on the corrosion aspects of hot, pressurized UF6/fluorine were also accumulated.
Flow control in a diffusing S-Duct
NASA Technical Reports Server (NTRS)
Vakili, A. D.; Wu, J. M.; Liver, P.; Bhat, M. K.
1985-01-01
Accurate measurements have been made of secondary flow in a 1.51 area ratio diffusing 30 deg - 30 deg S-Duct with circulair cross section. Turbulent flow was entering the duct at Mach number of 0.6, the boundary layer thickness at the duct entrance was ten percent of the duct inlet diameter. Through measurements made, local flow velocity vector as well as static and total pressures mapping of the flow at several stations were obtained. Strong secondary flow was measured in the first bend which continued into the second bend with new vorticity produced in there in the opposite direction. Surface oil flow visualization and wall pressures indicated a region of separated flow starting at theta approximately equal to 22 deg on the inside of the first bend up to theta approximately equal to 44 deg on the outside of the second bend. The flow separated in 'cyclone' form and never reattached in the duct. As a result of the secondary flow and the flow separation, significant total pressure distortion was observed at the exit of the duct. Using flow control devices the separation was eliminated while the exit distortion was improved.
Simulation analysis of air flow and turbulence statistics in a rib grit roughened duct.
Vogiatzis, I I; Denizopoulou, A C; Ntinas, G K; Fragos, V P
2014-01-01
The implementation of variable artificial roughness patterns on a surface is an effective technique to enhance the rate of heat transfer to fluid flow in the ducts of solar air heaters. Different geometries of roughness elements investigated have demonstrated the pivotal role that vortices and associated turbulence have on the heat transfer characteristics of solar air heater ducts by increasing the convective heat transfer coefficient. In this paper we investigate the two-dimensional, turbulent, unsteady flow around rectangular ribs of variable aspect ratios by directly solving the transient Navier-Stokes and continuity equations using the finite elements method. Flow characteristics and several aspects of turbulent flow are presented and discussed including velocity components and statistics of turbulence. The results reveal the impact that different rib lengths have on the computed mean quantities and turbulence statistics of the flow. The computed turbulence parameters show a clear tendency to diminish downstream with increasing rib length. Furthermore, the applied numerical method is capable of capturing small-scale flow structures resulting from the direct solution of Navier-Stokes and continuity equations.
Bonkovsky, Herbert L.; Kleiner, David E.; Gu, Jiezhun; Odin, Joseph A.; Russo, Mark W.; Navarro, Victor M.; Fontana, Robert J.; Ghabril, Marwan S.; Barnhart, Huiman; Hoofnagle, Jay H.
2016-01-01
Bile duct loss during the course of drug induced liver injury is uncommon but can be an indication of vanishing bile duct syndrome. In this work we assess the frequency, causes, clinical features and outcomes of cases of drug induced liver injury with histologically proven bile duct loss. All cases of drug induced liver injury enrolled into a prospective database over a ten year period that had undergone liver biopsies (n=363) were scored for the presence of bile duct loss and assessed for clinical and laboratory features, causes and outcomes. 26 of the 363 patients (7%) with drug, herbal or dietary supplement associated liver injury had bile duct loss on liver biopsy which was moderate to severe (<50% of portal areas with bile ducts) in 14 and mild (50–75%) in 12. The presenting clinical features of the 26 cases varied, but the most common clinical pattern was a severe cholestatic hepatitis. The implicated agents included amoxicillin/clavulanate (n=3), temozolomide (n=3), various herbal products (n=3), azithromycin (n=2) and 15 other medications or dietary supplements. Compared to those without, those with bile duct loss were more likely to develop chronic liver injury (94% vs 47%), which was usually cholestatic and sometimes severe. Five patients died and two others underwent liver transplantation for progressive cholestasis despite treatment with corticosteroids and ursodiol. The most predictive factor of poor outcome was the degree of bile duct loss on liver biopsy. Conclusions Bile duct loss during acute cholestatic hepatitis is an ominous early indicator of possible vanishing bile duct syndrome, for which at present there are no known means of prevention or therapy. PMID:27981596
NASA Astrophysics Data System (ADS)
Baker, Chad; Vuppuluri, Prem; Shi, Li; Hall, Matthew
2012-06-01
The performance and operating characteristics of a hypothetical thermoelectric generator system designed to extract waste heat from the exhaust of a medium-duty turbocharged diesel engine were modeled. The finite-difference model consisted of two integrated submodels: a heat exchanger model and a thermoelectric device model. The heat exchanger model specified a rectangular cross-sectional geometry with liquid coolant on the cold side, and accounted for the difference between the heat transfer rate from the exhaust and that to the coolant. With the spatial variation of the thermoelectric properties accounted for, the thermoelectric device model calculated the hot-side and cold-side heat flux for the temperature boundary conditions given for the thermoelectric elements, iterating until temperature and heat flux boundary conditions satisfied the convection conditions for both exhaust and coolant, and heat transfer in the thermoelectric device. A downhill simplex method was used to optimize the parameters that affected the electrical power output, including the thermoelectric leg height, thermoelectric n-type to p-type leg area ratio, thermoelectric leg area to void area ratio, load electrical resistance, exhaust duct height, coolant duct height, fin spacing in the exhaust duct, location in the engine exhaust system, and number of flow paths within the constrained package volume. The calculation results showed that the configuration with 32 straight fins was optimal across the 30-cm-wide duct for the case of a single duct with total height of 5.5 cm. In addition, three counterflow parallel ducts or flow paths were found to be an optimum number for the given size constraint of 5.5 cm total height, and parallel ducts with counterflow were a better configuration than serpentine flow. Based on the reported thermoelectric properties of MnSi1.75 and Mg2Si0.5Sn0.5, the maximum net electrical power achieved for the three parallel flow paths in a counterflow arrangement was 1.06 kW for package volume of 16.5 L and exhaust flow enthalpy flux of 122 kW.
Salivary duct cyst on lower lip: A rare entity and literature review
Tandon, Ankita; Sircar, Keya; Chowdhry, Aman; Bablani, Deepika
2014-01-01
Mucocele forms because of salivary gland mucous extravasation or retention and is usually related to trauma in the area of the lower lips. Salivary duct cyst, however, is a type of mucous retention cyst which is almost never located on the lower lip. The aim of this paper is to report this extremely rare salivary duct cyst present on the lower lip and to critically review the literature to build important concepts that would help clinicians in the diagnosis and treatment of this pathology. PMID:25364168
Salivary duct cyst on lower lip: A rare entity and literature review.
Tandon, Ankita; Sircar, Keya; Chowdhry, Aman; Bablani, Deepika
2014-09-01
Mucocele forms because of salivary gland mucous extravasation or retention and is usually related to trauma in the area of the lower lips. Salivary duct cyst, however, is a type of mucous retention cyst which is almost never located on the lower lip. The aim of this paper is to report this extremely rare salivary duct cyst present on the lower lip and to critically review the literature to build important concepts that would help clinicians in the diagnosis and treatment of this pathology.
1988-03-01
Hepatocellular degeneration and loss may accompany this change. Minimnal to severe 3 foci- minimal. BILE DUCT HYPERPLASIA Aging F344 rats frequently have foci...may or may not ensue. Score .Scoring Bile Duct Hyperplasia ".’-’."Score 1 1 to 3 portal areas have hyperplastic bile (trace) ducts. 2 4 to 9 portal...sclerosis are present. 4 Pericholangiolar fibrosis is from moderate to (marked) severe, with from mild to severe sclerosis in addition to hyperplasia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pallin, Simon B.; Boudreaux, Philip R.; Jackson, Roderick K.
2014-10-01
A sealed or unvented attic is an energy-efficient envelope component that can reduce the amount of energy a house consumes for space conditioning if the air handler and/or ducts are located in the attic. The attic is typically sealed by using spray foam on the underside of the roof deck and covering the soffit, ridge and gable vents to minimize air leakage from the attic to the outside. This approach can save up to 10% in space-conditioning energy when ducts are located in the attic (DOE 2013). Past research done by ORNL and Florida Solar Energy Center suggests that inmore » more hot, humid climates, an unvented attic could potentially create a more humid, uncomfortable living environment than a vented attic (Colon 2011, Boudreaux, Pallin et al. 2013). Research showed that controlling the higher indoor humidity could reduce the energy savings from the sealed, unvented attic, which in turn would decrease the energy savings payback. Research also showed that the roof assembly (5.5 inches of open-cell foam, 1inch of closed-cell foam, OSB, felt paper, and asphalt shingles) stored moisture, thus acting as a moisture buffer. During the fall and winter, the roof assembly stored moisture and during the spring and summer it released moisture. This phenomenon is not seen in a vented attic, in which the air exchange rate to the outside is greater and, in the winter, helps to dehumidify the attic air. It was also seen that in a vented attic, the direction of water vapor diffusion is on average from the attic to the interior of the house. Air leakage from the attic to the interior also occurs during more of the year in a house with an unvented attic than in one with a vented attic. These discoveries show that the moisture dynamics in a house with an unvented attic are much different from those in a house with a vented attic. This study reports on a series of computer model investigations completed to determine the key variables impacting indoor comfort and the durability of roof assemblies against moisture. The key variables investigated were the leakage area from the attic to the outside, leakage area from the attic to the interior, leakage area from the interior to the outside, supply duct leakage in the attic, and interior moisture generation. These investigations are described in this report.« less
Single channel double-duct liquid metal electrical generator using a magnetohydrodynamic device
Haaland, C.M.; Deeds, W.E.
1999-07-13
A single channel double-duct liquid metal electrical generator using a magnetohydrodynamic (MHD) device. The single channel device provides useful output AC electric energy. The generator includes a two-cylinder linear-piston engine which drives liquid metal in a single channel looped around one side of the MHD device to form a double-duct contra-flowing liquid metal MHD generator. A flow conduit network and drive mechanism are provided for moving liquid metal with an oscillating flow through a static magnetic field to produce useful AC electric energy at practical voltages and currents. Variable stroke is obtained by controlling the quantity of liquid metal in the channel. High efficiency is obtained over a wide range of frequency and power output. 5 figs.
Single channel double-duct liquid metal electrical generator using a magnetohydrodynamic device
Haaland, Carsten M.; Deeds, W. Edward
1999-01-01
A single channel double-duct liquid metal electrical generator using a magnetohydrodynamic (MHD) device. The single channel device provides useful output AC electric energy. The generator includes a two-cylinder linear-piston engine which drives liquid metal in a single channel looped around one side of the MHD device to form a double-duct contra-flowing liquid metal MHD generator. A flow conduit network and drive mechanism are provided for moving liquid metal with an oscillating flow through a static magnetic field to produce useful AC electric energy at practical voltages and currents. Variable stroke is obtained by controlling the quantity of liquid metal in the channel. High efficiency is obtained over a wide range of frequency and power output.
FET. Exhaust duct and stack. Plan, elevation, foundation, details. Ralph ...
FET. Exhaust duct and stack. Plan, elevation, foundation, details. Ralph M. Parsons 1480-10 ANP/GE-5-716-S-3. Date: February 1959. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0716-00-693-107474 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Stimpert, D. L.; Clemons, A.
1977-01-01
Sound data which were obtained during tests of a 50.8 cm diameter, subsonic tip speed, low pressure ratio fan were analyzed. The test matrix was divided into two major investigations: (1) source noise reduction techniques; and (2) aft duct noise reduction with acoustic treatment. Source noise reduction techniques were investigated which include minimizing second harmonic noise by varying vane/blade ratio, variation in spacing, and lowering the Mach number through the vane row to lower fan broadband noise. Treatment in the aft duct which includes flow noise effects, faceplate porosity, rotor OGV treatment, slant cell treatment, and splitter simulation with variable depth on the outer wall and constant thickness treatment on the inner wall was investigated. Variable boundary conditions such as variation in treatment panel thickness and orientation, and mixed porosity combined with variable thickness were examined. Significant results are reported.
Inflammation and glandular duct dilatation of the tongue from patients with chronic Chagas disease.
de Lima Pereira, Sanívia Aparecida; Rodrigues, Denise Bertulucci Rocha; da Fonseca Ferraz, Mara Lúcia; da Cunha Castro, Eumenia Costa; dos Reis, Marlene Antonia; de Paula Antunes Teixeira, Vicente
2006-01-01
The purpose of this study was to evaluate morphologically the tongue of individuals with chronic Chagas disease (CD) in comparison to the non-chagasic ones. Twenty-four protocol cases of autopsies were selected. They were subdivided into CD patients (10 cases) and non-chagasic ones (14 cases). The morphometric analysis was accomplished for the tongue muscle and salivary glands duct lumen area. In three CD patients, perineuritis was found, and two of them showed megaesophagus and megacolon. The intensity of the inflammation in the von Ebner's glands, the tongue muscles, and the salivary glands duct lumen area was significantly higher in the CD patients. We concluded that the CD patients show salivary glands duct dilatation, which probably would have a relation with alterations in the autonomic nervous system. The inflammation found in CD patients is in accordance with that described in comparative studies on the digestive tract and heart. These morphological findings suggest that the histopathological analysis of the tongue associated with other organs, or even in an isolated manner, can add in the diagnosis and pathogenesis of the CD chronic phase.
Study of unconventional propulsion system concepts for use in a long range transport
NASA Technical Reports Server (NTRS)
Champagne, G. A.
1973-01-01
The noise level of an uncoventional propulsion system for the next generation of subsonic, long-range transport aircraft is discussed. The desired noise level may be achieved by: (1) a fixed geometry, high bypass ratio turbofan with a geared two-stage fan and advanced acoustic treatment or (2) a moderate bypass ratio turbofan with a variable pitch two-stage fan, variable primary and duct nozzles, and advanced acoustic treatment. The geared fan system meets the noise goal with minimum economic penalty. Comparison of the noise levels at takeoff and landing in combination with the economic penalties required to achieve the lower noise levels at specific noise measuring stations, indicate that both area reduction and current certification prodedures should be used to ascertain the point of diminishing returns in establishing future noise goals.
Premix fuels study applicable to duct burner conditions for a variable cycle engine
NASA Technical Reports Server (NTRS)
Venkataramani, K. S.
1978-01-01
Emission levels and performance of a premixing Jet-A/air duct burner were measured at reference conditions representative of take-off and cruise for a variable cycle engine. In a parametric variation sequence of tests, data were obtained at inlet temperatures of 400, 500 and 600K at equivalence ratios varying from 0.9 to the lean stability limit. Ignition was achieved at all the reference conditions although the CO levels were very high. Significant nonuniformity across the combustor was observed for the emissions at the take-off condition. At a reference Mach number of 0.117 and an inlet temperature of 600K, corresponding to a simulated cruise condition, the NOx emission level was approximately 1 gm/kg-fuel.
NASA Technical Reports Server (NTRS)
Lohmann, R. P.; Mador, R. J.
1979-01-01
An evaluation was conducted with a three stage Vorbix duct burner to determine the performance and emissions characteristics of the concept and to refine the configuration to provide acceptable durability and operational characteristics for its use in the variable cycle engine (VCE) testbed program. The tests were conducted at representative takeoff, transonic climb, and supersonic cruise inlet conditions for the VSCE-502B study engine. The test stand, the emissions sampling and analysis equipment, and the supporting flow visualization rigs are described. The performance parameters including the fuel-air ratio, the combustion efficiency/exit temperature, thrust efficiency, and gaseous emissions calculations are defined. The test procedures are reviewed and the results are discussed.
Vanishing bile duct syndrome in Hodgkin's lymphoma: A case report and literature review.
Bakhit, Mena; McCarty, Thomas R; Park, Sunhee; Njei, Basile; Cho, Margaret; Karagozian, Raffi; Liapakis, AnnMarie
2017-01-14
Vanishing bile duct syndrome (VBDS) has been described in different pathologic conditions including infection, ischemia, adverse drug reactions, autoimmune diseases, allograft rejection, and humoral factors associated with malignancy. It is an acquired condition characterized by progressive destruction and loss of the intra-hepatic bile ducts leading to cholestasis. Prognosis is variable and partially dependent upon the etiology of bile duct injury. Irreversible bile duct loss leads to significant ductopenia, biliary cirrhosis, liver failure, and death. If biliary epithelial regeneration occurs, clinical recovery may occur over a period of months to years. VBDS has been described in a number of cases of patients with Hodgkin's lymphoma (HL) where it is thought to be a paraneoplastic phenomenon. This case describes a 25-year-old man found on liver biopsy to have VBDS. Given poor response to medical treatment, the patient underwent transplant evaluation at that time and was found to have classical stage IIB HL. Early recognition of this underlying cause or association of VBDS, including laboratory screening, and physical exam for lymphadenopathy are paramount to identifying potential underlying VBDS-associated malignancy. Here we review the literature of HL-associated VBDS and report a case of diagnosed HL with biopsy proven VBDS.
Arterial supply of human and bovine testes: a topographic and morphometric comparison study.
Polguj, M; Jędrzejewski, K S; Topol, M
2010-11-01
The aim of the study was to compare the arteries supplying human and bovine masculine gonads. The study was made on two extremely different types of location of the mediastinum testis. The study was made on 100 (50 human and 50 bovine) corrosive casts of the testicular, cremasteric, and deference duct arteries. The differences between the species included different courses of the testicular artery inside the spermatic duct, the relative size of the three arterial diameters, and the morphology of the anastomoses of the arteries. In human testicular arteries, the course inside the spermatic course was more variable than in that of bulls. The artery was straighter and in 80% of the cases did not form the loops which were present in 100% of the bovine specimens. The bovine testicular artery was significantly wider in relation to the cremasteric and deferens duct arteries than the human one. This finding suggests that collateral blood flow to the testis was less effective in bulls than in men. The human testicular artery directly connected the other two with its terminal branches. The bovine testicular artery connected with the cremasteric and deferens duct arteries indirectly by means of its deferens duct branch.
Truss-Integrated Thermoformed Ductwork Final Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steven Winter; Dianne Griffiths; Ravi Gorthala
2007-08-30
This report summarizes a multi-year research effort to develop a leak-free duct system that can be readily installed within the thermal envelope. There are numerous efforts underway to improve duct system efficiency. Most of these involve modifications to current technology such as air sealing techniques like mastic and aeroseal, snap together duct connections, and greater levels of insulation. This project sought to make a more significant stride forward by introducing a duct system of a material that can be more readily sealed and can exhibit lower friction losses. The research focused on the use of smooth internal surface, low frictionmore » plastic ducts that could be easily installed with very low air leakage. The initial system concept that was proposed and researched in Phase I focused on the use of thermoformed plastic ducts installed in a recessed roof truss underneath the attic insulation. A bench top thermoformed system was developed and tested during Phase I of the project. In Phase II, a first generation duct system utilizing a resin impregnated fiberglass duct product was designed and specified. The system was installed and tested in an Atlanta area home. Following this installation research and correspondence with code officials was undertaken to alleviate the continued concern over the code acceptance of plastic ducts in above ground applications. A Committee Interpretation response was received from the International Code Council (ICC) stating that plastic ducts were allowed, but must be manufactured from materials complying with Class 0 or Class 1 rating. With assurance of code acceptance, a plastic duct system using rotomolded high density polyethylene ducts that had passed the material test requirements by impregnating the material with a fire retardant during the molding process was installed in the basement of a new ranch-style home in Madison, WI. A series of measurements to evaluate the performance benefits relative to a similar control house with a standard sheet metal installation were made.« less
Bonkovsky, Herbert L; Kleiner, David E; Gu, Jiezhun; Odin, Joseph A; Russo, Mark W; Navarro, Victor M; Fontana, Robert J; Ghabril, Marwan S; Barnhart, Huiman; Hoofnagle, Jay H
2017-04-01
Bile duct loss during the course of drug-induced liver injury is uncommon, but can be an indication of vanishing bile duct syndrome (VBDS). In this work, we assess the frequency, causes, clinical features, and outcomes of cases of drug-induced liver injury with histologically proven bile duct loss. All cases of drug-induced liver injury enrolled into a prospective database over a 10-year period that had undergone liver biopsies (n = 363) were scored for the presence of bile duct loss and assessed for clinical and laboratory features, causes, and outcomes. Twenty-six of the 363 patients (7%) with drug-, herbal-, or dietary-supplement-associated liver injury had bile duct loss on liver biopsy, which was moderate to severe (<50% of portal areas with bile ducts) in 14 and mild (50%-75%) in 12. The presenting clinical features of the 26 cases varied, but the most common clinical pattern was a severe cholestatic hepatitis. The implicated agents included amoxicillin/clavulanate (n = 3), temozolomide (n = 3), various herbal products (n = 3), azithromycin (n = 2), and 15 other medications or dietary supplements. Compared to those without, those with bile duct loss were more likely to develop chronic liver injury (94% vs. 47%), which was usually cholestatic and sometimes severe. Five patients died and 2 others underwent liver transplantation for progressive cholestasis despite treatment with corticosteroids and ursodiol. The most predictive factor of poor outcome was the degree of bile duct loss on liver biopsy. Bile duct loss during acute cholestatic hepatitis is an ominous early indicator of possible VBDS, for which at present there are no known means of prevention or therapy. (Hepatology 2017;65:1267-1277). © 2016 by the American Association for the Study of Liver Diseases.
Flow in out-of-plane double S-bends
NASA Technical Reports Server (NTRS)
Schmidt, M. C.; Whitelaw, J. H.; Yianneskis, M.
1987-01-01
An experimental investigation of developing flows through a combination of out-of-plane S-bend ducts was conducted to gain insight into the redirection of flow in geometries similar to those encountered in practical aircraft wing-root intake ducts. The present double S-bend was fabricated by placing previously investigated S-ducts and S-diffusers in series and with perpendicular planes of symmetry. Laser-Doppler anemometry was employed to measure the three components of mean velocity, the corresponding rms quantities, and Reynolds stresses in the rectangular cross-section ducts. Due to limited optical access, only two mean and rms velocity components were resolved in the circular cross-section ducts. The velocity measurements were complemented by wall static pressure measurements. The data indicates that the flows at the exit are complex and asymmetric. Secondary flows generated by the pressure field in the first S-duct are complemented or counteracted by the secondary flows produced by the area expansion and the curvature of the S-diffuser. The results indicate the dominance of the inlet conditions and geometry upon the development of secondary flows and demonstrate that the flows are predominantly pressure-controlled. The pressure distribution caused by the duct geometry determines the direction and magnitude of the bulk flow while the turbulence dictates the mixing characteristics and profiles in the near wall region.
Impedance Eduction in Large Ducts Containing Higher-Order Modes and Grazing Flow
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2017-01-01
Impedance eduction test data are acquired in ducts with small and large cross-sectional areas at the NASA Langley Research Center. An improved data acquisition system in the large duct has resulted in increased control of the acoustic energy in source modes and more accurate resolution of higher-order duct modes compared to previous tests. Two impedance eduction methods that take advantage of the improved data acquisition to educe the liner impedance in grazing flow are presented. One method measures the axial propagation constant of a dominant mode in the liner test section (by implementing the Kumarsean and Tufts algorithm) and educes the impedance from an exact analytical expression. The second method solves numerically the convected Helmholtz equation and minimizes an objective function to obtain the liner impedance. The two methods are tested first on data synthesized from an exact mode solution and then on measured data. Results show that when the methods are applied to data acquired in the larger duct with a dominant higher-order mode, the same impedance spectra are educed as that obtained in the small duct where only the plane wave mode propagates. This result holds for each higher-order mode in the large duct provided that the higher-order mode is sufficiently attenuated by the liner.
NASA Technical Reports Server (NTRS)
Baskaran, S.
1974-01-01
The cut-off frequencies for high order circumferential modes were calculated for various eccentricities of an elliptic duct section. The problem was studied with a view to the reduction of jet engine compressor noise by elliptic ducts, instead of circular ducts. The cut-off frequencies for even functions decrease with increasing eccentricity. The third order eigen frequencies are oscillatory as the eccentricity increases for odd functions. The eigen frequencies decrease for higher order odd functions inasmuch as, for higher orders, they assume the same values as those for even functions. Deformation of a circular pipe into an elliptic one of sufficiently large eccentricity produces only a small reduction in the cut-off frequency, provided the area of the pipe section is kept invariable.
VCE testbed program planning and definition study
NASA Technical Reports Server (NTRS)
Westmoreland, J. S.; Godston, J.
1978-01-01
The flight definition of the Variable Stream Control Engine (VSCE) was updated to reflect design improvements in the two key components: (1) the low emissions duct burner, and (2) the coannular exhaust nozzle. The testbed design was defined and plans for the overall program were formulated. The effect of these improvements was evaluated for performance, emissions, noise, weight, and length. For experimental large scale testing of the duct burner and coannular nozzle, a design definition of the VCE testbed configuration was made. This included selecting the core engine, determining instrumentation requirements, and selecting the test facilities, in addition to defining control system and assembly requirements. Plans for a comprehensive test program to demonstrate the duct burner and nozzle technologies were formulated. The plans include both aeroacoustic and emissions testing.
Human Excreta as a Stable and Important Source of Atmospheric Ammonia in the Megacity of Shanghai
Chang, Yunhua; Deng, Congrui; Dore, Anthony J.; Zhuang, Guoshun
2015-01-01
Although human excreta as a NH3 source has been recognized globally, this source has never been quantitatively determined in cities, hampering efforts to fully assess the causes of urban air pollution. In the present study, the exhausts of 15 ceiling ducts from collecting septic tanks in 13 buildings with 6 function types were selected to quantify NH3 emission rates in the megacity of Shanghai. As a comparison, the ambient NH3 concentrations across Shanghai were also measured at 13 atmospheric monitoring sites. The concentrations of NH3 in the ceiling ducts (2809−2661+5803 μg m-3) outweigh those of the open air (~10 μg m-3) by 2–3 orders of magnitude, and there is no significant difference between different seasons. δ15N values of NH3 emitted from two ceiling ducts are also seasonally consistent, suggesting that human excreta may be a stable source of NH3 in urban areas. The NH3 concentration levels were variable and dependent on the different building types and the level of human activity. NH3 emission rates of the six residential buildings (RBNH3) were in agreement with each other. Taking occupation time into account, we confined the range of the average NH3 emission factor for human excreta to be 2–4 times (with the best estimate of 3 times) of the averaged RBNH3 of 66.0±58.9 g NH3 capita-1 yr-1. With this emission factor, the population of ~21 million people living in the urban areas of Shanghai annually emitted approximately 1386 Mg NH3, which corresponds to over 11.4% of the total NH3 emissions in the Shanghai urban areas. The spatial distribution of NH3 emissions from human excreta based on population data was calculated for the city of Shanghai at a high-resolution (100×100 m). Our results demonstrate that human excreta should be included in official ammonia emission inventories. PMID:26656636
Srinivasa, Rajiv N; Chick, Jeffrey Forris Beecham; Hage, Anthony N; Gemmete, Joseph J; Murrey, Douglas C; Srinivasa, Ravi N
2018-04-01
To report approach, technical success, safety, and short-term outcomes of thoracic duct stent-graft reconstruction for the treatment of chylothorax. Two patients, 1 (50%) male and 1 (50%) female, with mean age of 38 years (range: 16-59 years) underwent endolymphatic thoracic duct stent-graft reconstruction between September 2016 and July 2017. Patients had radiographic left-sided chylothoraces (n = 2) from idiopathic causes (n = 1) and heart transplantation (n = 1). In both (100%) patients, antegrade lymphatic access was used to opacify the thoracic duct after which retrograde access was used for thoracic duct stent-graft placement. Pelvic lymphangiography technical success, antegrade cisterna chyli cannulation technical success, thoracic duct opacification technical success, retrograde thoracic duct access technical success, thoracic duct stent-graft reconstruction technical success, ethiodized oil volume, contrast volume, estimated blood loss, procedure time, fluoroscopy time, radiation dose, clinical success, complications, deaths, and follow-up were recorded. Pelvic lymphangiography, antegrade cisterna chyli cannulation, thoracic duct opacification, retrograde thoracic duct access, and thoracic duct stent-graft reconstruction were technically successful in both (100%) patients. Mean ethiodized oil volume was 8 mL (range: 5-10 mL). Mean contrast volume was 13 mL (range: 5-20 mL). Mean estimated blood loss was 13 mL (range: 10-15 mL). Mean fluoroscopy time was 50.4 min (range: 31.2-69.7 min). Mean dose area product and reference air kerma were 954.4 μGmy 2 (range: 701-1,208 μGmy 2 ) and 83.5 mGy (range: 59-108 mGy), respectively. Chylothorax resolved in both (100%) patients. There were no minor or major complications directly related to the procedure. Thoracic duct stent-graft reconstruction may be a technically successful and safe alternative to thoracic duct embolization, disruption, and surgical ligation for the treatment of chylothorax. Additional studies are warranted. Copyright © 2017 Elsevier Inc. All rights reserved.
Observations of Strong Surface Radar Ducts over the Persian Gulf.
NASA Astrophysics Data System (ADS)
Brooks, Ian M.; Goroch, Andreas K.; Rogers, David P.
1999-09-01
Ducting of microwave radiation is a common phenomenon over the oceans. The height and strength of the duct are controlling factors for radar propagation and must be determined accurately to assess propagation ranges. A surface evaporation duct commonly forms due to the large gradient in specific humidity just above the sea surface; a deeper surface-based or elevated duct frequently is associated with the sudden change in temperature and humidity across the boundary layer inversion.In April 1996 the U.K. Meteorological Office C-130 Hercules research aircraft took part in the U.S. Navy Ship Antisubmarine Warfare Readiness/Effectiveness Measuring exercise (SHAREM-115) in the Persian Gulf by providing meteorological support and making measurements for the study of electromagnetic and electro-optical propagation. The boundary layer structure over the Gulf is influenced strongly by the surrounding desert landmass. Warm dry air flows from the desert over the cooler waters of the Gulf. Heat loss to the surface results in the formation of a stable internal boundary layer. The layer evolves continuously along wind, eventually forming a new marine atmospheric boundary layer. The stable stratification suppresses vertical mixing, trapping moisture within the layer and leading to an increase in refractive index and the formation of a strong boundary layer duct. A surface evaporation duct coexists with the boundary layer duct.In this paper the authors present aircraft- and ship-based observations of both the surface evaporation and boundary layer ducts. A series of sawtooth aircraft profiles map the boundary layer structure and provide spatially distributed estimates of the duct depth. The boundary layer duct is found to have considerable spatial variability in both depth and strength, and to evolve along wind over distances significant to naval operations (100 km). The depth of the evaporation duct is derived from a bulk parameterization based on Monin-Obukhov similarity theory using near-surface data taken by the C-130 during low-level (30 m) flight legs and by ship-based instrumentation. Good agreement is found between the two datasets. The estimated evaporation ducts are found to be generally uniform in depth; however, localized regions of greatly increased depth are observed on one day, and a marked change in boundary layer structure resulting in merging of the surface evaporation duct with the deeper boundary layer duct was observed on another. Both of these cases occurred within exceptionally shallow boundary layers (100 m), where the mean evaporation duct depths were estimated to be between 12 and 17 m. On the remaining three days the boundary layer depth was between 200 and 300 m, and evaporation duct depths were estimated to be between 20 and 35 m, varying by just a few meters over ranges of up to 200 km.The one-way radar propagation factor is modeled for a case with a pronounced change in duct depth. The case is modeled first with a series of measured profiles to define as accurately as possible the refractivity structure of the boundary layer, then with a single profile collocated with the radar antenna and assuming homogeneity. The results reveal large errors in the propagation factor when derived from a single profile.
Meisner, John W.; Moore, Robert M.; Bienvenue, Louis L.
1985-03-19
Electromagnetic linear induction pump for liquid metal which includes a unitary pump duct. The duct comprises two substantially flat parallel spaced-apart wall members, one being located above the other and two parallel opposing side members interconnecting the wall members. Located within the duct are a plurality of web members interconnecting the wall members and extending parallel to the side members whereby the wall members, side members and web members define a plurality of fluid passageways, each of the fluid passageways having substantially the same cross-sectional flow area. Attached to an outer surface of each side member is an electrically conductive end bar for the passage of an induced current therethrough. A multi-phase, electrical stator is located adjacent each of the wall members. The duct, stators, and end bars are enclosed in a housing which is provided with an inlet and outlet in fluid communication with opposite ends of the fluid passageways in the pump duct. In accordance with a preferred embodiment, the inlet and outlet includes a transition means which provides for a transition from a round cross-sectional flow path to a substantially rectangular cross-sectional flow path defined by the pump duct.
Tamoxifen decreases the myofibroblast count in the healing bile duct tissue of pigs
Siqueira, Orlando Hiroshi Kiono; Filho, Benedito Herani; de Paula, Rafael Erthal; Áscoli, Fábio Otero; da Nóbrega, Antonio Cláudio Lucas; Carvalho, Angela Cristina Gouvêa; Pires, Andréa Rodrigues Cordovil; Gaglionone, Nicolle Cavalcante; Cunha, Karin Soares Gonçalves; Granjeiro, José Mauro
2013-01-01
OBJECTIVE: The aim of this study was to evaluate the effect of oral tamoxifen treatment on the number of myofibroblasts present during the healing process after experimental bile duct injury. METHODS: The sample consisted of 16 pigs that were divided into two groups (the control and study groups). Incisions and suturing of the bile ducts were performed in the two groups. Tamoxifen (20 mg/day) was administered only to the study group. The animals were sacrificed after 30 days. Quantification of myofibroblasts in the biliary ducts was made through immunohistochemistry analysis using anti-alpha smooth muscle actin of the smooth muscle antibody. Immunohistochemical quantification was performed using a digital image system. RESULTS: In the animals treated with tamoxifen (20 mg/day), there was a significant reduction in immunostaining for alpha smooth muscle actin compared with the control group (0.1155 vs. 0.2021, p = 0.046). CONCLUSION: Tamoxifen reduced the expression of alpha smooth muscle actin in the healing tissue after bile duct injury, suggesting a decrease in myofibroblasts in the scarred area of the pig biliary tract. These data suggest that tamoxifen could be used in the prevention of biliary tract stenosis after bile duct surgeries. PMID:23420165
47 CFR 1.1409 - Commission consideration of the complaint.
Code of Federal Regulations, 2011 CFR
2011-10-01
... percentage of the total usable space, or the percentage of the total duct or conduit capacity, which is... section: Rate = Space Factor × Cost Where Cost in Urbanized Service Areas = 0.66 × (Net Cost of a Bare... telecommunications carriers: ER29JN01.014 simplified as: ER29JN01.015 If no inner-duct is installed the fraction, “1...
NASA Technical Reports Server (NTRS)
Wing, David J.
1998-01-01
The static internal performance of a multiaxis-thrust-vectoring, spherical convergent flap (SCF) nozzle with a non-rectangular divergent duct was obtained in the model preparation area of the Langley 16-Foot Transonic Tunnel. Duct cross sections of hexagonal and bowtie shapes were tested. Additional geometric parameters included throat area (power setting), pitch flap deflection angle, and yaw gimbal angle. Nozzle pressure ratio was varied from 2 to 12 for dry power configurations and from 2 to 6 for afterburning power configurations. Approximately a 1-percent loss in thrust efficiency from SCF nozzles with a rectangular divergent duct was incurred as a result of internal oblique shocks in the flow field. The internal oblique shocks were the result of cross flow generated by the vee-shaped geometric throat. The hexagonal and bowtie nozzles had mirror-imaged flow fields and therefore similar thrust performance. Thrust vectoring was not hampered by the three-dimensional internal geometry of the nozzles. Flow visualization indicates pitch thrust-vector angles larger than 10' may be achievable with minimal adverse effect on or a possible gain in resultant thrust efficiency as compared with the performance at a pitch thrust-vector angle of 10 deg.
Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Wanyu R.; Joh, Jeffrey; Sherman, Max H.
2012-08-01
LBNL Residential Diagnostics Database (ResDB) contains blower door measurements and other diagnostic test results of homes in United States. Of these, approximately 134,000 single-family detached homes have sufficient information for the analysis of air leakage in relation to a number of housing characteristics. We performed regression analysis to consider the correlation between normalized leakage and a number of explanatory variables: IECC climate zone, floor area, height, year built, foundation type, duct location, and other characteristics. The regression model explains 68% of the observed variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements of approximatelymore » 23,000 homes that participated in weatherization assistant programs (WAPs) or residential energy efficiency programs. The two types of programs achieve rather similar reductions in normalized leakage: 30% for WAPs and 20% for other energy programs.« less
Tebala, Giovanni D
2006-05-01
The technique of laparoscopic cholecystectomy (LC) still has areas of refinements. To decrease the number of ports, a cannula may be replaced by a percutaneous suture suspension of the gallbladder. The risk of tissue injury caused by repeat blind extraction and insertion of various instruments in and out of the abdomen may be decreased by the use of the multipurpose harmonic dissector. One hundred consecutive patients with symptomatic cholelithiasis underwent 3-port LC entirely performed by harmonic dissector without cystic duct and artery clipping. In 8 cases, a fourth trocar was necessary. In 2 cases, the cystic duct was clipped after an unsafe ultrasound sealing. In 1 case, continuous bleeding from the liver required the use of diathermy. No common bile duct injury was registered. The 3-port harmonic LC is a feasible, effective, and safe technique.
Flowmeter for gas-entrained solids flow
Porges, Karl G.
1990-01-01
An apparatus and method for the measurement of solids feedrate in a gas-entrained solids flow conveyance system. The apparatus and method of the present invention include a vertical duct connecting a source of solids to the gas-entrained flow conveyance system, a control valve positioned in the vertical duct, and a capacitive densitometer positioned along the duct at a location a known distance below the control valved so that the solid feedrate, Q, of the gas entrained flow can be determined by Q=S.rho..phi.V.sub.S where S is the cross sectional area of the duct, .rho. is the density of the solid, .phi. is the solid volume fraction determined by the capacitive densitometer, and v.sub.S is the local solid velocity which can be inferred from the konown distance of the capacitive densitometer below the control valve.
Vanishing bile duct syndrome in Hodgkin’s lymphoma: A case report and literature review
Bakhit, Mena; McCarty, Thomas R; Park, Sunhee; Njei, Basile; Cho, Margaret; Karagozian, Raffi; Liapakis, AnnMarie
2017-01-01
Vanishing bile duct syndrome (VBDS) has been described in different pathologic conditions including infection, ischemia, adverse drug reactions, autoimmune diseases, allograft rejection, and humoral factors associated with malignancy. It is an acquired condition characterized by progressive destruction and loss of the intra-hepatic bile ducts leading to cholestasis. Prognosis is variable and partially dependent upon the etiology of bile duct injury. Irreversible bile duct loss leads to significant ductopenia, biliary cirrhosis, liver failure, and death. If biliary epithelial regeneration occurs, clinical recovery may occur over a period of months to years. VBDS has been described in a number of cases of patients with Hodgkin’s lymphoma (HL) where it is thought to be a paraneoplastic phenomenon. This case describes a 25-year-old man found on liver biopsy to have VBDS. Given poor response to medical treatment, the patient underwent transplant evaluation at that time and was found to have classical stage IIB HL. Early recognition of this underlying cause or association of VBDS, including laboratory screening, and physical exam for lymphadenopathy are paramount to identifying potential underlying VBDS-associated malignancy. Here we review the literature of HL-associated VBDS and report a case of diagnosed HL with biopsy proven VBDS. PMID:28127210
[Caroli's disease: congenital cystic and segmentary dilatation of the intrahepatic bile ducts].
Serra, C A; Recalde, E B; Martellotto, G I
1987-01-01
Congenital cystic segmentary dilatation of the intrahepatic biliary ducts is a rare disease. Although several cases has been described in medical literature, its occurrence such as it was originally referred is exceptional. Some cases coexist with congenital hepatic fibrosis and portal hypertension. A characteristic phenomenon is the formation of stones and canalicular infection. In this article, three cases of Caroli disease (females, 57, 53 and 58 years old) are described. Case n 1 was a complex malformation including: a) cystic and segmentary dilatations of the intrahepatic biliar ducts; b) intra and extrahepatic lithiasis and recurrent infections; c) fusion of the choledocus and gallbladder in a common sac; d) hepatic cavernosus hemangioma and a supernumerarious lobe. Case n 2 showed: a) cystic and segmentary dilatation of the intrahepatic biliar ducts; b) portal fibrosis; c) polycystic kidneys; d) portal hypertension. Case n 3 showed: a) cystic and segmentary dilatation of the intrahepatic biliar ducts; b) portal fibrosis; c) polycystic kidneys and spleen; d) portal hypertension. Prognostic of this patients is variable and depends on the recurrent infections and the coexistence of other malformations which are frequently severe. Surgery is the only treatment for the disease although there are no definite conclusions concerning the long-term results.
Algorithm of dynamic regulation of a system of duct, for a high accuracy climatic system
NASA Astrophysics Data System (ADS)
Arbatskiy, A. A.; Afonina, G. N.; Glazov, V. S.
2017-11-01
Currently, major part of climatic system, are stationary in projected mode only. At the same time, many modern industrial sites, require constant or periodical changes in technological process. That is 80% of the time, the industrial site is not require ventilation system in projected mode and high precision of climatic parameters must maintain. While that not constantly is in use for climatic systems, which use in parallel for different rooms, we will be have a problem for balance of duct system. For this problem, was created the algorithm for quantity regulation, with minimal changes. Dynamic duct system: Developed of parallel control system of air balance, with high precision of climatic parameters. The Algorithm provide a permanent pressure in main duct, in different a flow of air. Therefore, the ending devises air flow have only one parameter for regulation - flaps open area. Precision of regulation increase and the climatic system provide high precision for temperature and humidity (0,5C for temperature, 5% for relative humidity). Result: The research has been made in CFD-system - PHOENICS. Results for velocity of air in duct, for pressure of air in duct for different operation mode, has been obtained. Equation for air valves positions, with different parameters for climate in room’s, has been obtained. Energy saving potential for dynamic duct system, for different types of a rooms, has been calculated.
Steps toward quantitative infrasound propagation modeling
NASA Astrophysics Data System (ADS)
Waxler, Roger; Assink, Jelle; Lalande, Jean-Marie; Velea, Doru
2016-04-01
Realistic propagation modeling requires propagation models capable of incorporating the relevant physical phenomena as well as sufficiently accurate atmospheric specifications. The wind speed and temperature gradients in the atmosphere provide multiple ducts in which low frequency sound, infrasound, can propagate efficiently. The winds in the atmosphere are quite variable, both temporally and spatially, causing the sound ducts to fluctuate. For ground to ground propagation the ducts can be borderline in that small perturbations can create or destroy a duct. In such cases the signal propagation is very sensitive to fluctuations in the wind, often producing highly dispersed signals. The accuracy of atmospheric specifications is constantly improving as sounding technology develops. There is, however, a disconnect between sound propagation and atmospheric specification in that atmospheric specifications are necessarily statistical in nature while sound propagates through a particular atmospheric state. In addition infrasonic signals can travel to great altitudes, on the order of 120 km, before refracting back to earth. At such altitudes the atmosphere becomes quite rare causing sound propagation to become highly non-linear and attenuating. Approaches to these problems will be presented.
Radiative interactions in laminar duct flows
NASA Technical Reports Server (NTRS)
Trivedi, P. A.; Tiwari, S. N.
1990-01-01
Analyses and numerical procedures are presented for infrared radiative energy transfer in gases when other modes of energy transfer occur simultaneously. Two types of geometries are considered, a parallel plate duct and a circular duct. Fully developed laminar incompressible flows of absorbing-emitting species in black surfaced ducts are considered under the conditions of uniform wall heat flux. The participating species considered are OH, CO, CO2, and H2O. Nongray as well as gray formulations are developed for both geometries. Appropriate limiting solutions of the governing equations are obtained and conduction-radiation interaction parameters are evaluated. Tien and Lowder's wide band model correlation was used in nongray formulation. Numerical procedures are presented to solve the integro-differential equations for both geometries. The range of physical variables considered are 300 to 2000 K for temperature, 0.1 to 100.0 atm for pressure, and 0.1 to 100 cm spacings between plates/radius of the tube. An extensive parametric study based on nongray formulation is presented. Results obtained for different flow conditions indicate that the radiative interactions can be quite significant in fully developed incompressible flows.
Jang, Jin-Young; Park, Taesung; Lee, Selyeong; Kim, Yongkang; Lee, Seung Yeoun; Kim, Sun-Whe; Kim, Song-Cheol; Song, Ki-Byung; Yamamoto, Masakazu; Hatori, Takashi; Hirono, Seiko; Satoi, Sohei; Fujii, Tsutomu; Hirano, Satoshi; Hashimoto, Yasushi; Shimizu, Yashuhiro; Choi, Dong Wook; Choi, Seong Ho; Heo, Jin Seok; Motoi, Fuyuhiko; Matsumoto, Ippei; Lee, Woo Jung; Kang, Chang Moo; Han, Ho-Seong; Yoon, Yoo-Seok; Sho, Masayuki; Nagano, Hiroaki; Honda, Goro; Kim, Sang Geol; Yu, Hee Chul; Chung, Jun Chul; Nagakawa, Yuichi; Seo, Hyung Il; Yamaue, Hiroki
2017-12-01
This study evaluated individual risks of malignancy and proposed a nomogram for predicting malignancy of branch duct type intraductal papillary mucinous neoplasms (BD-IPMNs) using the large database for IPMN. Although consensus guidelines list several malignancy predicting factors in patients with BD-IPMN, those variables have different predictability and individual quantitative prediction of malignancy risk is limited. Clinicopathological factors predictive of malignancy were retrospectively analyzed in 2525 patients with biopsy proven BD-IPMN at 22 tertiary hospitals in Korea and Japan. The patients with main duct dilatation >10 mm and inaccurate information were excluded. The study cohort consisted of 2258 patients. Malignant IPMNs were defined as those with high grade dysplasia and associated invasive carcinoma. Of 2258 patients, 986 (43.7%) had low, 443 (19.6%) had intermediate, 398 (17.6%) had high grade dysplasia, and 431 (19.1%) had invasive carcinoma. To construct and validate the nomogram, patients were randomly allocated into training and validation sets, with fixed ratios of benign and malignant lesions. Multiple logistic regression analysis resulted in five variables (cyst size, duct dilatation, mural nodule, serum CA19-9, and CEA) being selected to construct the nomogram. In the validation set, this nomogram showed excellent discrimination power through a 1000 times bootstrapped calibration test. A nomogram predicting malignancy in patients with BD-IPMN was constructed using a logistic regression model. This nomogram may be useful in identifying patients at risk of malignancy and for selecting optimal treatment methods. The nomogram is freely available at http://statgen.snu.ac.kr/software/nomogramIPMN.
Protective effect of Urtica dioica on liver damage induced by biliary obstruction in rats.
Oguz, Serhat; Kanter, Mehmet; Erboga, Mustafa; Ibis, Cem
2013-10-01
The aim of this study was to evaluate the possible protective effects of Urtica dioica (UD) against liver damage in the common bile duct-ligated rats. A total of 24 male Sprague Dawley rats were divided into three groups, namely, control, bile duct ligation (BDL) and BDL + received UD groups, containing eight animals in each group. The rats in UD-treated groups were given UD oils (2 ml/kg) once a day intraperitoneally for 2 weeks starting 3 days prior to BDL operation. The change demonstrating the bile duct proliferation and fibrosis in expanded portal tracts includes the extension of proliferated bile ducts into the lobules; inflammatory cell infiltration into the widened portal areas were observed in BDL group. Treatment of BDL with UD attenuated alterations in liver histology. The α-smooth muscle actin, cytokeratin-positive ductular proliferation and the activity of terminal deoxynucleotidyl transferase dUTP nick end labeling in the BDL were observed to be reduced with the UD treatment. The data indicate that UD attenuates BDL-induced cholestatic liver injury, bile duct proliferation and fibrosis.
The generation of sound by vorticity waves in swirling duct flows
NASA Technical Reports Server (NTRS)
Howe, M. S.; Liu, J. T. C.
1977-01-01
Swirling flow in an axisymmetric duct can support vorticity waves propagating parallel to the axis of the duct. When the cross-sectional area of the duct changes a portion of the wave energy is scattered into secondary vorticity and sound waves. Thus the swirling flow in the jet pipe of an aeroengine provides a mechanism whereby disturbances produced by unsteady combustion or turbine blading can be propagated along the pipe and subsequently scattered into aerodynamic sound. In this paper a linearized model of this process is examined for low Mach number swirling flow in a duct of infinite extent. It is shown that the amplitude of the scattered acoustic pressure waves is proportional to the product of the characteristic swirl velocity and the perturbation velocity of the vorticity wave. The sound produced in this way may therefore be of more significance than that generated by vorticity fluctuations in the absence of swirl, for which the acoustic pressure is proportional to the square of the perturbation velocity. The results of the analysis are discussed in relation to the problem of excess jet noise.
NASA Astrophysics Data System (ADS)
Muhmood, Tahir; Xia, Mingzhu; Lei, Wu; Wang, Fengyun
2018-02-01
Novel duct graphitic carbon nitride (DCN) was successfully prepared using the temperature control method in a quartz tube furnace from commercially available melamine and evaluated against the photo-degradation of latent organic pollutants, acarbose (ACB). These prepared materials were characterized by UV-Vis spectroscopy, Fourier transform infrared spectra, x-ray photoelectron spectroscopy, x-ray diffraction, transmission electron microscopy and scanning electron microscopy. The characterization results indicated that the synthesized material was in the form of a duct-like structure and has greater adsorption capacity and photocatalytic ability as compared to traditionally synthesized graphitic carbon nitride materials. The DCN split theACB completely into many intermediates, which were depicted in the HPLC-MS spectrum for knowing the acarbose photo-degrdation pathway. The duct-like morphology of graphitic carbon nitride has improved properties, such as increasing the surface area and decelerating the e -/h + recombination, which increase the light absorbance ability with enhanced photoactivity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagino, Ko; Yokozawa, Junji; Sasaki, Yu
Highlights: Black-Right-Pointing-Pointer Insulin secretion was increased during the OGTT or IVGTT in mesenteric lymph duct-ligated rats. Black-Right-Pointing-Pointer Proliferation of islet {beta}-cells was upregulated in lymph duct-ligated rats. Black-Right-Pointing-Pointer Mesenteric lymph duct flow has a role in glucose metabolism. -- Abstract: Background and aims: It has been suggested that intestinal lymph flow plays an important role in insulin secretion and glucose metabolism after meals. In this study, we investigated the influence of ligation of the mesenteric lymph duct on glucose metabolism and islet {beta}-cells in rats. Methods: Male Sprague-Dawley rats (10 weeks old) were divided into two groups: one underwent ligationmore » of the mesenteric lymph duct above the cistern (ligation group), and the other underwent a sham operation (sham group). After 1 and 2 weeks, fasting plasma concentrations of glucose, insulin, triglyceride, glucose-dependent insulinotropic polypeptide (GIP), and the active form of glucagon-like peptide-1 (GLP-1) were measured. At 2 weeks after the operation, the oral glucose tolerance test (OGTT) and intravenous glucose tolerance test (IVGTT) were performed. After the rats had been sacrificed, the insulin content of the pancreas was measured and the proliferation of {beta}-cells was assessed immunohistochemically using antibodies against insulin and Ki-67. Results: During the OGTT, the ligation group showed a significant decrease in the plasma glucose concentration at 120 min (p < 0.05) and a significant increase in the plasma insulin concentration by more than 2-fold at 15 min (p < 0.01). On the other hand, the plasma GIP concentration was significantly decreased at 60 min (p < 0.01) in the ligated group, while the active form of GLP-1 showed a significantly higher level at 90 min (1.7-fold; p < 0.05) and 120 min (2.5-fold; p < 0.01). During the IVGTT, the plasma insulin concentration in the ligation group was significantly higher at 2 min (more than 1.4-fold; p < 0.05). Immunohistochemistry showed that the ratios of {beta}-cell area/acinar cell area and {beta}-cell area/islet area, and also {beta}-cell proliferation, were significantly higher in the ligation group than in the sham group (p < 0.05, p < 0.01 and p < 0.01, respectively). The insulin content per unit wet weight of pancreas was also significantly increased in the ligation group (p < 0.05). Conclusions: In rats with ligation of the mesenteric lymph duct, insulin secretion during the OGTT or IVGTT was higher, and the insulin content and {beta}-cell proliferation in the pancreas were also increased. Our data show that mesenteric lymph duct flow has a role in glucose metabolism.« less
Siegel, Dustin S; Aldridge, Robert D; Rheubert, Justin L; Gribbins, Kevin M; Sever, David M; Trauth, Stanley E
2013-03-01
The ducts associated with sperm transport from the testicular lobules to the Wolffian ducts in Ambystoma maculatum were examined with transmission electron microscopy. Based on the ultrastructure and historical precedence, new terminology for this network of ducts is proposed that better represents primary hypotheses of homology. Furthermore, the terminology proposed better characterizes the distinct regions of the sperm transport ducts in salamanders based on anatomy and should, therefore, lead to more accurate comparisons in the future. While developing the above ontology, we also tested the hypothesis that nephrons from the genital kidney are modified from those of the pelvic kidney due to the fact that the former nephrons function in sperm transport. Our ultrastructural analysis of the genital kidney supports this hypothesis, as the basal plasma membrane of distinct functional regions of the nephron (proximal convoluted tubule, distal convoluted tubule, and collecting tubule) appear less folded (indicating decreased surface area and reduced reabsorption efficiency) and the proximal convoluted tubule possesses ciliated epithelial cells along its entire length. Furthermore, visible luminal filtrate is absent from the nephrons of the genital kidney throughout their entire length. Thus, it appears that the nephrons of the genital kidney have reduced reabsorptive capacity and ciliated cells of the proximal convoluted tubule may increase the movement of immature sperm through the sperm transport ducts or aid in the mixing of seminal fluids within the ducts. Copyright © 2012 Wiley Periodicals, Inc.
Mebius, Mirthe J; van der Laan, Michelle E; Verhagen, Elise A; Roofthooft, Marcus Tr; Bos, Arend F; Kooi, Elisabeth Mw
2016-12-01
Evidence suggests that hypoxic-ischemic brain injury in infants with congenital heart disease already occurs during early life. The aim of our study was, therefore, to assess the course of regional cerebral oxygen saturation (r c SO 2 ) and fractional tissue oxygen extraction (FTOE) during the first 72h after birth in infants with prenatally diagnosed duct-dependent congenital heart disease. In addition, we identified clinical parameters that were associated with r c SO 2 . We included 56 infants with duct-dependent congenital heart disease. We measured arterial oxygen saturation (SpO 2 ) and r c SO 2 during the first 72h after birth. Simultaneously, we calculated FTOE. We observed median r c SO 2 values of approximately 60%, a decreasing FTOE from 0.34 on day 1 to 0.28 on day 3 and stable preductal SpO 2 values around 90%. Several clinical variables were associated with r c SO 2 . In a multiple linear regression model only type of CHD and preductal SpO 2 were significant predictors of r c SO 2 during the first three days after birth. Infants with a duct-dependent pulmonary circulation had up to 12% lower r c SO 2 values than infants with a duct-dependent systemic circulation. We demonstrated that, during the first three days after birth, cerebral oxygen saturation is low in infants with duct-dependent congenital heart disease. Furthermore, this study provides preoperative reference values of r c SO 2 and FTOE in infants with duct-dependent CHD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Reichert, Paulo R.; Renz, John F.; D’Albuquerque, Luiz A. C.; Rosenthal, Philip; Lim, Robert C.; Roberts, John P.; Ascher, Nancy L.; Emond, Jean C.
2000-01-01
Objective To evaluate intrahepatic vascular and biliary anatomy of the left lateral segment (LLS) as applied to living-donor and split-liver transplantation. Summary Background Data Living-donor and split-liver transplantation are innovative surgical techniques that have expanded the donor pool. Fundamental to the application of these techniques is an understanding of intrahepatic vascular and biliary anatomy. Methods Pathologic data obtained from cadaveric liver corrosion casts and liver dissections were clinically correlated with the anatomical findings obtained during split-liver, living-donor, and reduced-liver transplants. Results The anatomical relation of the left bile duct system with respect to the left portal venous system was constant, with the left bile duct superior to the extrahepatic transverse portion of the left portal vein. Four specific patterns of left biliary anatomy and three patterns of left hepatic venous drainage were identified and described. Conclusions Although highly variable, the biliary and hepatic venous anatomy of the LLS can be broadly categorized into distinct patterns. The identification of the LLS duct origin lateral to the umbilical fissure in segment 4 in 50% of cast specimens is significant in the performance of split-liver and living-donor transplantation, because dissection of the graft pedicle at the level of the round ligament will result in separate ducts from segments 2 and 3 in most patients, with the further possibility of an anterior segment 4 duct. A connective tissue bile duct plate, which can be clinically identified, is described to guide dissection of the segment 2 and 3 biliary radicles. PMID:11066137
NASA Astrophysics Data System (ADS)
Yamakawa, Emi; Yoshimoto, Masahiro; Kinsho, Michikazu
At the injection area of the RCS ring in the J-PARC, residual gamma dose at the rectangular ceramic ducts, especially immediately downstream of the charge-exchanged foil, has increased with the output beam power. In order to investigate the cause of high residual activities, residual gamma dose and radioactive sources produced at the exterior surface of the ducts have been measured by a GM survey meter and a handy type of Germanium (Ge) semiconductor detector in the case of 181 MeV injected proton beam energy. With these measurements, it is revealed that the radioactive sources produced by nuclear reactions cause the high activities at the injection area. For a better understanding of phenomena in the injection area, various simulations have been done with the PHITS Monte Carlo code. The distribution of radioactive sources and residual gamma dose rate obtained by the calculations are consistent with the measurement results. With this consistency, secondary neutrons and protons derived from nuclear reactions at the charge-exchanged foil are the dominant cause to high residual gamma dose at the ceramic ducts in the injection area. These measurements and calculations are unique approaches to reveal the cause of high residual dose around the foil. This study is essential for the future of high-intensity proton accelerators using a stripping foil.
APPARATUS FOR DETECTING AND LOCATING PRESENCE OF FLUIDS
Williamson, R.R.
1958-09-16
A system is described fur detecting water leaks in water-cooled neutronic reactors by utilizing an electrical hygrometer having a resistance element variable with the moisture content. The graphite blocks, forming the moderator in many types of reactors, coniain ducts in which helium gas is circulated. When a leak occurs in a coolant tube, the water will seep through the graphite until it oozes into one of the helium ducts, where it will be swept along with the helium into a system of pipes that connect each of the helium ducts. By inserting an electric hygrometer in each of these pipes and connecting it to an alarm system, the moisture content of the helium will cause a change in the electrical resistance of the hygrometer which will initiate a signal alarm indicating the presence and position of the leaky water tube in the reactor.
NASA Technical Reports Server (NTRS)
Dean, P. D.
1978-01-01
A systems concept procedure is described for the optimization of acoustic duct liner design for both uniform and multisegment types. The concept was implemented by the use of a double reverberant chamber flow duct facility coupled with sophisticated computer control and acoustic analysis systems. The optimization procedure for liner insertion loss was based on the concept of variable liner impedance produced by bias air flow through a multilayer, resonant cavity liner. A multiple microphone technique for in situ wall impedance measurements was used and successfully adapted to produce automated measurements for all liner configurations tested. The complete validation of the systems concept was prevented by the inability to optimize the insertion loss using bias flow induced wall impedance changes. This inability appeared to be a direct function of the presence of a higher order energy carrying modes which were not influenced significantly by the wall impedance changes.
Application of finite difference techniques to noise propagation in jet engine ducts
NASA Technical Reports Server (NTRS)
Baumeister, K. J.
1973-01-01
A finite difference formulation is presented for wave propagation in a rectangular two-dimensional duct without steady flow. The difference technique, which should be used in the study of acoustically treated inlet and exhausts ducts used in turbofan engines, can readily handle acoustical flow field complications such as axial variations in wall impedance and cross-section area. In the numerical analysis, the continuous acoustic field is lumped into a series of grid points in which the pressure and velocity at each grid point are separated into real and imaginary terms. An example calculation is also presented for the sound attenuation in a two-dimensional straight soft-walled suppressor.
Application of finite difference techniques to noise propagation in jet engine ducts
NASA Technical Reports Server (NTRS)
Baumeister, K. J.
1973-01-01
A finite difference formulation is presented for wave propagation in a rectangular two-dimensional duct without steady flow. The difference technique, which should be useful in the study of acoustically treated inlet and exhausts ducts used in turbofan engines, can readily handle acoustical flow field complications such as axial variations in wall impedance and cross section area. In the numerical analysis, the continuous acoustic field is lumped into a series of grid points in which the pressure and velocity at each grid point are separated into real and imaginary terms. An example calculation is also presented for the sound attenuation in a two-dimensional straight soft-walled suppressor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kan, Tomoko, E-mail: tkan@grape.med.tottori-u.ac.j; Kodani, Kazuhiko; Michimoto, Koichi
Purpose: To elucidate the radiation-induced damage to the microstructure of the parotid gland using high-resolution magnetic resonance imaging. Methods and Materials: High-resolution magnetic resonance imaging of the parotid gland was performed before radiotherapy (RT) and during the RT period or {<=}3 weeks after RT completion for 12 head-and-neck cancer patients using a 1.5-T scanner with a microscopy coil. The maximal cross-sectional area of the gland was evaluated, and changes in the internal architecture of the gland were assessed both visually and quantitatively. Results: Magnetic resonance images were obtained at a median parotid gland dose of 36 Gy (range, 11-64). Accordingmore » to the quantitative analysis, the maximal cross-sectional area of the gland was reduced, the width of the main duct was narrowed, and the intensity ratio of the main duct lumen to background was significantly decreased after RT (p <.0001). According to the visual assessment, the width of the main duct tended to narrow and the contrast of the duct lumen tended to be decreased, but no significant differences were noted. The visibility of the duct branches was unclear in 10 patients (p = .039), and the septum became dense in 11 patients (p = .006) after RT. Conclusion: High-resolution magnetic resonance imaging is a noninvasive method of evaluating radiation-induced changes to the internal architecture of the parotid gland. Morphologic changes in the irradiated parotid gland were demonstrated during the RT course even when a relatively small dose was delivered to the gland.« less
Zero leakage separable and semipermanent ducting joints
NASA Technical Reports Server (NTRS)
Mischel, H. T.
1973-01-01
A study program has been conducted to explore new methods of achieving zero leakage, separable and semipermanent, ducting joints for space flight vehicles. The study consisted of a search of literature of existing zero leakage methods, the generation of concepts of new methods of achieving the desired zero leakage criteria and the development of detailed analysis and design of a selected concept. Other techniques of leak detection were explored with a view toward improving this area.
Acoustic wave propagation in heterogeneous structures including experimental validation
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.; Dahl, Milo D.
1989-01-01
A finite element model was developed to solve for the acoustic pressure and energy fields in a heterogeneous suppressor. The derivations from the governing equations assumed that the material properties could vary with position resulting in a heterogeneous variable property two-dimensional wave equation. This eliminated the necessity of finding the boundary conditions between different materials. For a two-media region consisting of part air and part bulk absorber, a model was used to describe the bulk absorber properties in two directions. Complex metallic structures inside the air duct are simulated by simply changing element properties from air to the structural material in a pattern to describe the desired shapes. To verify the numerical theory, experiments were conducted without flow in a rectangular duct with a single folded cavity mounted above the duct and absorbing material mounted inside a cavity. Changes in a nearly plane wave sound field were measured on the wall opposite the absorbing cavity. Fairly good agreement was found in the standing wave pattern upstream of the absorber and in the decay of pressure level opposite the absorber, as a function of distance along the duct. The finite element model provides a convenient method for evaluating the acoustic properties of bulk absorbers.
NPSS Multidisciplinary Integration and Analysis
NASA Technical Reports Server (NTRS)
Hall, Edward J.; Rasche, Joseph; Simons, Todd A.; Hoyniak, Daniel
2006-01-01
The objective of this task was to enhance the capability of the Numerical Propulsion System Simulation (NPSS) by expanding its reach into the high-fidelity multidisciplinary analysis area. This task investigated numerical techniques to convert between cold static to hot running geometry of compressor blades. Numerical calculations of blade deformations were iteratively done with high fidelity flow simulations together with high fidelity structural analysis of the compressor blade. The flow simulations were performed with the Advanced Ducted Propfan Analysis (ADPAC) code, while structural analyses were performed with the ANSYS code. High fidelity analyses were used to evaluate the effects on performance of: variations in tip clearance, uncertainty in manufacturing tolerance, variable inlet guide vane scheduling, and the effects of rotational speed on the hot running geometry of the compressor blades.
Detonation duct gas generator demonstration program
NASA Technical Reports Server (NTRS)
Wortman, Andrew; Brinlee, Gayl A.; Othmer, Peter; Whelan, Michael A.
1991-01-01
The feasibility of the generation of detonation waves moving periodically across high speed channel flow is experimentally demonstrated. Such waves are essential to the concept of compressing requirements and increasing the engine pressure compressor with the objective of reducing conventional compressor requirements and increasing the engine thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock wave losses are reduced by an order of magnitude. The ultimate objective is to use such detonation ducts downstream of a low pressure gas turbine compressor to produce a high overall pressure ratio thermodynamic cycle. A 4 foot long, 1 inch x 12 inch cross-section, detonation duct was operated in a blow-down mode using compressed air reservoirs. Liquid or vapor propane was injected through injectors or solenoid valves located in the plenum or the duct itself. Detonation waves were generated when the mixture was ignited by a row of spark plugs in the duct wall. Problems with fuel injection and mixing limited the air speeds to about Mach 0.5, frequencies to below 10 Hz, and measured pressure ratios of about 5 to 6. The feasibility of the gas dynamic compression was demonstrated and the critical problem areas were identified.
Guillén, Larissa; Adaime, Ricardo; Birke, Andrea; Velázquez, Olinda; Angeles, Guillermo; Ortega, Fernando; Ruíz, Eliel; Aluja, Martín
2017-04-01
We determined the influence of resin ducts, sap content, and fruit physicochemical features of four mango cultivars (Criollo, Manila, Ataulfo, and Tommy Atkins) on their susceptibility to the attack of the two most pestiferous fruit fly species infesting mangoes in Mexico: Anastrepha ludens (Loew) and Anastrepha obliqua (Macquart). We performed three studies: 1) analysis of resin ducts in mango fruit exocarp to determine the density and area occupied by resin ducts in each mango cultivar, 2) assessment of mango physicochemical features including fruit sap content, and 3) a forced infestation trial under field conditions using enclosed fruit-bearing branches to expose mangoes to gravid A. ludens or A. obliqua females. Infestation rates, development time from egg to prepupae and pupae, pupal weight, and percent of adult emergence, were assessed. 'Ataulfo' and 'Tommy Atkins' cultivars exhibited the highest resin duct density and sap content, the lowest infestation rate, and had a negative effect on immature development and pupal weight. In sharp contrast, 'Manila' and 'Criollo' cultivars, with the lowest resin duct density and sap content, were highly susceptible to A. ludens and A. obliqua attack. We conclude that sap content and the number, size, and distribution of resin ducts as well as firmness in mango fruit exocarp are all involved in the resistance of mango to A. ludens and A. obliqua attack. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Flow Through a Rectangular-to-Semiannular Diffusing Transition Duct
NASA Technical Reports Server (NTRS)
Foster, Jeff; Wendt, Bruce J.; Reichert, Bruce A.; Okiishi, Theodore H.
1997-01-01
Rectangular-to-semiannular diffusing transition ducts are critical inlet components on supersonic airplanes having bifucated engine inlets. This paper documents measured details of the flow through a rectangular-to-semiannular transition duct having an expansion area ratio of 1.53. Three-dimensional velocity vectors and total pressures at the exit plane of the diffuser are presented. Surface oil-flow visualization and surface static pressure data are shown. The tests were conducted with an inlet Mach number of 0.786 and a Reynolds number based on the inlet centerline velocity and exit diameter of 3.2 x 10(exp 6). The measured data are compared with previously published computational results. The ability of vortex generators to reduce circumferential total pressure distortion is demonstrated.
Closeup view of the top of Space Shuttle Main Engine ...
Close-up view of the top of Space Shuttle Main Engine (SSME) 2057 mounted in a SSME Engine Handler in the Vertical Processing area of the SSME Processing Facility at Kennedy Space Center. The most prominent components in this view is the large Low-Pressure Oxidizer Turbopump (LPOTP) Discharge Duct wrapping itself around the right side of the engine assembly. The smaller tube to the left of LPOTP Discharge Duct is the High-Pressure Oxidizer Duct used to supply the turbine of the LPOTP. The other major feature in this view is the Low-Pressure Fuel Turbopump at the top of the engine assembly. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
Parametric measurements of the effect of in-duct orifice edge shape on its noise damping performance
NASA Astrophysics Data System (ADS)
Ji, Chenzhen; Zhao, Dan; Han, Nuomin; Li, Jing
2016-12-01
Acoustic liners perforated with thousands of millimeter-size orifices are widely used in aero-engines and gas turbine engines as an effective noise damper. In this work, experimental investigations of the acoustic damping effect of in-duct perforated orifices are performed on a cold-flow pipe. A mean flow (also known as bias flow) is applied and its flow rate is variable. Emphasis is placed on the effect of the orifice edge shape. For this, 16 in-duct orifices with different edge shapes and porosities are designed and manufactured by using 3D printing technology and conventional laser cutting technique. The damping effect of these in-duct orifices is characterized by using power absorption coefficient Δ and reflection coefficient χ from 100 to 1000 Hz. The performances of these orifices are found to be either improved or deteriorated, depending on (1) edge shape, (2) the ratio T/d of orifice thickness to its diameter, (3) the bias flow Mach number, (4) downstream pipe length Ld and (5) porosity η via varying either the number N or surface area Ao of the orifices. In addition, modifying orifice edge does not lead to an increase of power absorption at lower frequency (⩽ 700 Hz). However, as the frequency is increased, the orifice with square (S-type) edge is found to be associated with 10 percent more power absorption. It is interesting to find that T/d over the tested range (≤ 0.5) has little influence on its damping capacity. However, the mean bias flow Mach number Ma and porosity η are shown to play critical roles on determining the noise damping performance of these orifices. Maximum power absorption Δmax is found to occur at Ma ≈ 0.018, while the optimum porosity corresponding to Δmax is approximately 7 percent. The present parametric measurements shed light on the roles of orifice edge shape, porosity and mean flow on its noise damping capacity, and facilitate the design of effective perforated liners.
Matsumura, Yoko; Michels, Jan; Appel, Esther; Gorb, Stanislav N
2017-02-01
The peculiar phenomenon of hyper-elongation of intromittent organs is well known in a number of insect groups. However, the unresolved questions of how and why such a phenomenon originated independently many times continue to attract biologists' attention. To be able to detect the evolutionary driving mechanisms that enabled insects to repeatedly acquire such a peculiarity, first of all the structural key features and the mechanics of these organs have to be determined. In the present study, the morphology of the reproductive organs of two species of the beetle genus Cassida, with a special focus on the male structures, was scrutinised in detail during copulation and at rest using different microscopy techniques. We found that the hyper-elongated structure of the intromittent organ, called flagellum, is part of the male ejaculatory duct. When the flagellum is inserted into the female spermathecal duct, longitudinal muscles of the ejaculatory duct, but not the flagellum, are shortened. These results strongly suggest that the contraction of the longitudinal muscles of the ejaculatory duct causes propulsion of the flagellum into the highly spiralled spermathecal duct of the female. The tip of the cuticular flagellum is curled up, which can suggest that its physical properties differ from those of the rest of the flagellum. Considering the preceding modelling studies, this property aids the flagellum in penetrating within the highly spiralled and very variable female duct. Based on our morphological results and in comparison with the morphology of intromittent organs of other beetles, we discuss the evolutionary origin of the hyper-elongation in the Cassida species and propose a hypothesis that explains the independent origin of the hyper-elongation of intromittent organs. Copyright © 2016 Elsevier GmbH. All rights reserved.
Design and Construction of Foundations in Areas of Deep Seasonal Frost and Permafrost.
1980-08-01
soils later, during or following construction such as from roof drains, dry wells or condensate discharge, must be considered. e b. Construction when...thermal damage unless carefully controlled. Condensation of ice crystals in the ducts from moist air may also block the ventilating ducts if they are...guidance is available when needed. If 2 8mpers are installed they should be placed on the upwind side .Eliminating downwind dampers allows convection
1988-10-01
sample these ducts. This judgement was based on the following factors : 1. The ducts were open to the atmosphere. 2. RMA records of building area samples...selected based on several factors including piping arrangements, volume to be sampled, sampling equipment flow rates, and the flow rate necessary for...effective sampling. Therefore, each sampling point strategy and procedure was customized based on these factors . The individual specific sampling
Magnetic resonance T1 gradient-echo imaging in hepatolithiasis.
Safar, F; Kamura, T; Okamuto, K; Sasai, K; Gejyo, F
2005-01-01
We examined the role of magnetic resonance T1-weighted gradient-echo (MRT1-GE) imaging in hepatolithiasis. MRT1-GE, precontrast computed tomography (CT), and magnetic resonance cholangiopancreatography (MRCP) of 10 patients with hepatolithiasis were compared for their diagnostic accuracies in the detection and localization of intrahepatic calculi. The diagnosis of hepatolithiasis was confirmed by surgery. For localization of the stone, we divided the bile ducts into six areas: right and left hepatic ducts and bile ducts of the lateral, medial, right anterior, and right posterior segments of the liver. Chemical analysis of the stones was performed in eight patients. The total number of segments proved by surgery to contain stones was 18. Although not significantly different, the sensitivity of MRT1-GE was 77.8% (14 of 18 segments), higher than that of MRCP (66.7%, 12 of 18 segments) and that of CT (50%, nine of 18 segments). The sensitivity of magnetic resonance imaging (MRCP + MRT1) was significantly higher than that of CT (p < 0.01). Multiple logistic regression analysis showed that the result of surgery was significantly affected only by the result of magnetic resonance imaging. On MRT1-GE, all the depicted stones appeared as high-intensity signal areas within the low-intensity bile duct irrespective of their chemical composition. MRT1-GE imaging provides complementary information concerning hepatolithiasis.
Laboratory experiments on active suppression of advanced turboprop noise
NASA Technical Reports Server (NTRS)
Dittmar, J. H.
1985-01-01
The noise generated by supersonic tip speed propellers may be a cabin environment problem for future propeller-driven airplanes. Active suppression from speakers inside the airplane cabin has been proposed for canceling out this noise. The potential of active suppression of advanced turboprop noise was tested by using speakers in a rectangular duct. Experiments were first performed with sine wave signals. The results compared well with the ideal cancellation curve of noise as a function of phase angle. Recorded noise signals from subsonic and supersonic tip speed propellers were than used in the duct to deterthe potential for canceling their noise. The subsonic propeller data showed significant cancellations but less than those obtained with the sine wave. The blade-passing-tone cancellation curve for the supersonic propeller was very similar to the subsonic curve, indicating that it is potentially just as easy to cancel supersonic as subsonic propeller blade-passing-tone noise. Propeller duct data from a recorded propeller source and spatial data taken on a propeller-drive airplane showed generally good agreement when compared versus phase angle. This agreement, combined with the similarity of the subsonic and supersonic duct propeller data, indicates that the area of cancellation for advanced supersonic propellers will be similar to that measured on the airplane. Since the area of cancellation on the airplane was small, a method for improving the active noise suppression by using outside speakers is discussed.
Study of blade aspect ratio on a compressor front stage aerodynamic and mechanical design report
NASA Technical Reports Server (NTRS)
Burger, G. D.; Lee, D.; Snow, D. W.
1979-01-01
A single stage compressor was designed with the intent of demonstrating that, for a tip speed and hub-tip ratio typical of an advanced core compressor front stage, the use of low aspect ratio can permit high levels of blade loading to be achieved at an acceptable level of efficiency. The design pressure ratio is 1.8 at an adiabatic efficiency of 88.5 percent. Both rotor and stator have multiple-circular-arc airfoil sections. Variable IGV and stator vanes permit low speed matching adjustments. The design incorporates an inlet duct representative of an engine transition duct between fan and high pressure compressor.
NASA Technical Reports Server (NTRS)
Cole, G. L.; Willoh, R. G.
1975-01-01
A linearized mathematical analysis is presented for determining the response of normal shock position and subsonic duct pressures to flow-field perturbations upstream of the normal shock in mixed-compression supersonic inlets. The inlet duct cross-sectional area variation is approximated by constant-area sections; this approximation results in one-dimensional wave equations. A movable normal shock separates the supersonic and subsonic flow regions, and a choked exit is assumed for the inlet exit condition. The analysis leads to a closed-form matrix solution for the shock position and pressure transfer functions. Analytical frequency response results are compared with experimental data and a method of characteristics solution.
Wetland survey of selected areas in the K-24 Site Area of responsibility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosensteel, B.A.; Awl, D.J.
1995-07-01
In accordance with DOE Regulations for Compliance with Floodplain/Wetlands Environmental Review Requirements, wetland surveys were conducted in selected areas within the K-25 Area of Responsibility during the summer of 1994. These areas are Mitchell Branch, Poplar Creek, the K-770 OU, Duct Island Peninsula, the Powerhouse area, and the K-25 South Corner. Previously surveyed areas included in this report are the main plant area of the K-25 Site, the K-901 OU, the AVLIS site, and the K-25 South Site. Wetland determinations were based on the USACE methodology. Forty-four separate wetland areas, ranging in size from 0.13 to 4.23 ha, were identified.more » Wetlands were identified in all of the areas surveyed with the exception of the interior of the Duct Island Peninsula and the main plant area of the K-25 Site. Wetlands perform functions such as floodflow alteration, sediment stabilization, sediment and toxicant retention, nutrient transformation, production export, and support of aquatic species and wildlife diversity and abundance. The forested, scrub-shrub, and emergent wetlands identified in the K-25 area perform some or all of these functions to varying degrees.« less
ERIC Educational Resources Information Center
Leith, David E.
1976-01-01
Provides background information, defining areas within organ systems where physiological waterfalls exist. Describes pressure-flow relationships of elastic tubes (blood vessels, airways, renal tubules, various ducts). (CS)
Toward surface quantification of liver fibrosis progression
NASA Astrophysics Data System (ADS)
He, Yuting; Kang, Chiang Huen; Xu, Shuoyu; Tuo, Xiaoye; Trasti, Scott; Tai, Dean C. S.; Raja, Anju Mythreyi; Peng, Qiwen; So, Peter T. C.; Rajapakse, Jagath C.; Welsch, Roy; Yu, Hanry
2010-09-01
Monitoring liver fibrosis progression by liver biopsy is important for certain treatment decisions, but repeated biopsy is invasive. We envision redefinition or elimination of liver biopsy with surface scanning of the liver with minimally invasive optical methods. This would be possible only if the information contained on or near liver surfaces accurately reflects the liver fibrosis progression in the liver interior. In our study, we acquired the second-harmonic generation and two-photon excitation fluorescence microscopy images of liver tissues from bile duct-ligated rat model of liver fibrosis. We extracted morphology-based features, such as total collagen, collagen in bile duct areas, bile duct proliferation, and areas occupied by remnant hepatocytes, and defined the capsule and subcapsular regions on the liver surface based on image analysis of features. We discovered a strong correlation between the liver fibrosis progression on the anterior surface and interior in both liver lobes, where biopsy is typically obtained. The posterior surface exhibits less correlation with the rest of the liver. Therefore, scanning the anterior liver surface would obtain similar information to that obtained from biopsy for monitoring liver fibrosis progression.
Multimodal method for scattering of sound at a sudden area expansion in a duct with subsonic flow
NASA Astrophysics Data System (ADS)
Kooijman, G.; Testud, P.; Aurégan, Y.; Hirschberg, A.
2008-03-01
The scattering of sound at a sudden area expansion in a duct with subsonic mean flow has been modelled with a multimodal method. Technological applications are for instance internal combustion engine exhaust silencers and silencers in industrial duct systems. Both two-dimensional (2D) rectangular and 2D cylindrical geometry and uniform mean flow as well as non-uniform mean flow profiles are considered. Model results for the scattering of plane waves in case of uniform flow, in which case an infinitely thin shear layer is formed downstream of the area expansion, are compared to results obtained by other models in literature. Generally good agreement is found. Furthermore, model results for the scattering are compared to experimental data found in literature. Also here fairly good correspondence is observed. When employing a turbulent pipe flow profile in the model, instead of a uniform flow profile, the prediction for the downstream transmission- and upstream reflection coefficient is improved. However, worse agreement is observed for the upstream transmission and downstream reflection coefficient. On the contrary, employing a non-uniform jet flow profile, which represents a typical shear layer flow downstream of the expansion, gives worse agreement for the downstream transmission- and the upstream reflection coefficient, whereas prediction for the upstream transmission and downstream reflection coefficient improves.
LOFT. Mobile test building (TAN624) is recycled from ANP program ...
LOFT. Mobile test building (TAN-624) is recycled from ANP program for placement before LOFT containment building door. It has not yet been connected to containment building. Note borated water tank at right of dome. Narrow, vertical structure at right of door is shroud is shroud for air exhaust duct. Filter vaults lie between duct shroud and stack. Camera facing westerly. Date: 1974. INEEL negative no. 74-1072 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Modeling the compliance of polyurethane nanofiber tubes for artificial common bile duct
NASA Astrophysics Data System (ADS)
Moazeni, Najmeh; Vadood, Morteza; Semnani, Dariush; Hasani, Hossein
2018-02-01
The common bile duct is one of the body’s most sensitive organs and a polyurethane nanofiber tube can be used as a prosthetic of the common bile duct. The compliance is one of the most important properties of prosthetic which should be adequately compliant as long as possible to keep the behavioral integrity of prosthetic. In the present paper, the prosthetic compliance was measured and modeled using regression method and artificial neural network (ANN) based on the electrospinning process parameters such as polymer concentration, voltage, tip-to-collector distance and flow rate. Whereas, the ANN model contains different parameters affecting on the prediction accuracy directly, the genetic algorithm (GA) was used to optimize the ANN parameters. Finally, it was observed that the optimized ANN model by GA can predict the compliance with high accuracy (mean absolute percentage error = 8.57%). Moreover, the contribution of variables on the compliance was investigated through relative importance analysis and the optimum values of parameters for ideal compliance were determined.
NASA Astrophysics Data System (ADS)
Sochi, Taha
2016-09-01
Several deterministic and stochastic multi-variable global optimization algorithms (Conjugate Gradient, Nelder-Mead, Quasi-Newton and global) are investigated in conjunction with energy minimization principle to resolve the pressure and volumetric flow rate fields in single ducts and networks of interconnected ducts. The algorithms are tested with seven types of fluid: Newtonian, power law, Bingham, Herschel-Bulkley, Ellis, Ree-Eyring and Casson. The results obtained from all those algorithms for all these types of fluid agree very well with the analytically derived solutions as obtained from the traditional methods which are based on the conservation principles and fluid constitutive relations. The results confirm and generalize the findings of our previous investigations that the energy minimization principle is at the heart of the flow dynamics systems. The investigation also enriches the methods of computational fluid dynamics for solving the flow fields in tubes and networks for various types of Newtonian and non-Newtonian fluids.
Heat Transfer in a Superelliptic Transition Duct
NASA Technical Reports Server (NTRS)
Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven
2008-01-01
Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.
NASA Astrophysics Data System (ADS)
Manousaki, D.; Panagiotopoulou, A.; Bizimi, V.; Haynes, M. S.; Love, S.; Kallergi, M.
2017-11-01
The purpose of this study was the generation of ground truth files (GTFs) of the breast ducts from 3D images of the Invenia™ Automated Breast Ultrasound System (ABUS) system (GE Healthcare, Little Chalfont, UK) and the application of these GTFs for the optimization of the imaging protocol and the evaluation of a computer aided detection (CADe) algorithm developed for automated duct detection. Six lactating, nursing volunteers were scanned with the ABUS before and right after breastfeeding their infants. An expert in breast ultrasound generated rough outlines of the milk-filled ducts in the transaxial slices of all image volumes and the final GTFs were created by using thresholding and smoothing tools in ImageJ. In addition, a CADe algorithm automatically segmented duct like areas and its results were compared to the expert’s GTFs by estimating true positive fraction (TPF) or % overlap. The CADe output differed significantly from the expert’s but both detected a smaller than expected volume of the ducts due to insufficient contrast (ducts were partially filled with milk), discontinuities, and artifacts. GTFs were used to modify the imaging protocol and improve the CADe method. In conclusion, electronic GTFs provide a valuable tool in the optimization of a tomographic imaging system, the imaging protocol, and the CADe algorithms. Their generation, however, is an extremely time consuming, strenuous process, particularly for multi-slice examinations, and alternatives based on phantoms or simulations are highly desirable.
Cross spectra between temperature and pressure in a constant area duct downstream of a combustor
NASA Technical Reports Server (NTRS)
Miles, J. H.; Wasserbauer, C. A.; Krejsa, E. A.
1983-01-01
The feasibility of measuring pressure temperature cross spectra and coherence and temperature-temperature cross spectra and coherence at spatially separated points along with pressure and temperature auto-spectra in a combustion rig was investigated. The measurements were made near the inlet and exit of a 6.44 m long duct attached to a J-47 combustor. The fuel used was Jet A. The cross spectra and coherence measurements show the pressure and temperature fluctuations correlate best at low frequencies. At the inlet the phenomena controlling the phase relationship between pressure and temperature could not be identified. However, at the duct exit the phase angle of the pressure is related to the phase angle of the temperature by the convected flow time delay.
NASA Technical Reports Server (NTRS)
Allen, John L
1956-01-01
Unsteady shock-induced separation of the ramp boundary layer was reduced and stabilized more effectively by external perforations than by external or internal slots. At Mach 2.0 peak total-pressure recovery was increased from 0.802 to 0.89 and stable mass-flow range was increased 185 percent over that for the solid ramp. Peak pressure recovery occurred just before instability. The 7 and one-third-diameter duct ahead of the engine reduced large total-pressure distortions but was not as successful for small distortions as obtained with throat bleed. By removing boundary-layer air the bypass nearly recovered the total-pressure loss due to the long duct.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could removemore » between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.« less
Air duct systems for roadway stabilization over permafrost areas
DOT National Transportation Integrated Search
1984-03-01
In the discontinuous permafrost regions of Alaska it is not always possible to route roads over non-permafrost ground. For areas like these, highway engineers face a tremendous design challenge in attempting to provide a stable roadway base. Several ...
Sugimoto, Motokazu; Sonntag, David P; Flint, Greggory S; Boyce, Cody J; Kirkham, John C; Harris, Tyler J; Carr, Sean M; Nelson, Brent D; Bell, Don A; Barton, Joshua G; Traverso, L William
2018-07-01
Pancreatic duct disruption (PDD) after acute pancreatitis can cause pancreatic collections in the early phase and biliary stenosis (BS) or gastric outlet obstruction (GOO) in the late phase. We aimed to document those late complications after moderate or severe acute pancreatitis. Between September 2010 and August 2014, 141 patients showed pancreatic collections on computed tomography. Percutaneous drainage was primarily performed for patients with signs or symptoms of uncontrolled pancreatic juice leakage. Pancreatic duct disruption was defined as persistent amylase-rich drain fluid or a pancreatic duct cut-off on imaging. Clinical course of the patients who developed BS or GOO was investigated. Among the 141 patients with collections, 33 patients showed PDD in the pancreatic head/neck area. Among them, 9 patients (27%) developed BS 65 days after onset and required stenting for 150 days, and 5 patients (15%) developed GOO 92 days after onset and required gastric decompression and jejunal tube feeding for 147 days (days shown in median). All 33 patients recovered successfully without requiring surgical intervention. Anatomic proximity of the bile duct or duodenum to the site of PDD and severe inflammation seemed to contribute to the late onset of BS or GOO. Conservative management successfully reversed these complications.
Bile duct injury: management options during and after gallbladder surgery.
Vecchio, R; MacFadyen, B V; Ricardo, A E
1998-06-01
Proper management of iatrogenic bile duct injuries is mandatory to avoid immediate or late life threatening sequelae. Results of surgery depend mainly on the type of injury, the detection of the injury, and the timing of the surgery. Lesions detected during cholecystectomy should be repaired immediately, preferably with an end-to-side biliary anastomosis, a Roux-en-Y bilio-enteric anastomosis, or by the insertion of a T-tube. Bile duct injuries detected in the postoperative phase require a multidisciplinary approach and an algorithm for treatment of each type of lesion is proposed. In bile peritonitis with biliary obstruction and/or transection and in tight long strictures, which develop several months after cholecystectomy, a Roux-en-Y hepatico-jejunostomy is the most commonly performed operation. Other surgical techniques include a "mucosal graft" procedure and intrahepatic biliary enteric anastomoses, which may be required in difficult high-biliary lesions. Endoscopy and/or interventional radiology offer the best treatment options in bile duct leaks and in short ductal strictures that involve less than 50% of the bile duct lumen. In these injuries, surgical management should be performed only in the failure of nonsurgical methods. Because these lesions involve complicated biliary surgery, therapeutic endoscopy, and interventional radiology, treatment should be performed where there is expertise in all three areas. Copyright 1998 W.B. Saunders Company.
Morphometric Measurements of Bony Nasolacrimal Canal in Children.
Ela, Araz Server; Cigdem, Kalaycik Ertugay; Karagoz, Yesim; Yigit, Ozgur; Longur, Ecem Sevim
2018-05-01
Morphology and dimensions of the bony nasolacrimal canal duct (BNLD) as a key factor in the development of primary acquired nasolacrimal duct obstruction. We aimed to obtain detailed morphometric analysis of BNLD in children without nasolacrimal duct pathology by using computed tomography and provide standard measurements by means of age which could be utilized in planning management or in invasive interventions. Picture Archiving Communication Systems database of our hospital's radiology department was searched for this retrospective study. Subjects were under 18 years of age who had undergone a paranasal, maxillofacial, or temporal bone high-resolution computed tomography scan in last 2 years with various indications. Those with fractures including facial bones and/or nasolacrimal canal or history of nasolacrimal duct pathology were excluded from the study. We measured the diameter, angle, and surface area of BNLD. A total number of 136 subjects (86 boys, 50 girls) were included in the study. The average age was 7.3 ± 5.1 years. We documented statistically significantly positive correlation between all measured diameters and ages (P < 0.001), whereas there was a negative association between mean angle and age (P < 0.001). Mean angle is defined as the angle between BNLD and nasal floor. The surface area of BNLD was found to be significantly increasing depending on age (P < 0.001). However, we could not find any significant association between gender and measured parameters (P > 0.050). Our study demonstrated that development of BNLD continues during childhood, regardless of gender.
Wave scattering in spatially inhomogeneous currents
NASA Astrophysics Data System (ADS)
Churilov, Semyon; Ermakov, Andrei; Stepanyants, Yury
2017-09-01
We analytically study a scattering of long linear surface waves on stationary currents in a duct (canal) of constant depth and variable width. It is assumed that the background velocity linearly increases or decreases with the longitudinal coordinate due to the gradual variation of duct width. Such a model admits an analytical solution of the problem in hand, and we calculate the scattering coefficients as functions of incident wave frequency for all possible cases of sub-, super-, and transcritical currents. For completeness we study both cocurrent and countercurrent wave propagation in accelerating and decelerating currents. The results obtained are analyzed in application to recent analog gravity experiments and shed light on the problem of hydrodynamic modeling of Hawking radiation.
Tefera, Endale; Qureshi, Shakeel A; Bermudez-Cañete, Ramòn; Rubio, Lola
2015-01-01
At high altitude, patent arterial ducts tend to be larger and associated with pulmonary hypertension. Patent ductus arteriosus device closure in this background could be challenging. We report our experience with percutaneous closure of patent arterial ducts using a variety of devices in patients residing in a high altitude. This is a retrospective review of the case records of 145 patients (age 9 months-20 years, mean 5.6 ± 3.9 years, and weight 7-54 kg, mean 17.7 ± 9.4) with duct sizes ranging between 2 and 21 mm, (mean, 5.8 ± 2.7) who underwent percutaneous closure of patent arterial ducts. One hundred thirty-six (93.8%) of the patients were from a geographic area of 2100-2800 m above sea level. Successful device closure was achieved in 143 cases. It was difficult to achieve device stability in two patients with expansile ducts. Therefore, they were treated surgically. The devices used were various types of duct occluder devices in 131 patients, while atrial and ventricular septal occluders were used in eight patients. For the group, mean systolic pulmonary artery (PA) pressure decreased from 47.0 ± 16.7 mmHg before occlusion to 29.0 ± 7.4 mmHg after occlusion (P ≤ 0.001)., mean diastolic PA pressure from 25.0 ± 10.9 mmHg to 14.8 ± 6.0 mmHg and the average mean PA pressure decreased from 35.9 ± 13.5 mmHg to 21.1 ± 6.5 mmHg. Complications (4.8%) included device and coil embolization, bleeding, and pulse loss. On follow-up (mean duration of 36.1 ± 12.1 months, range 12-62 months), 137 patients were in functional class 1, 3 had residual shunt, 2 had device migration and one patient had persisting pulse loss. Successful duct closure was achieved in the vast majority of patients, even though the ducts were larger and significant number of them had pulmonary hypertension in this high altitude group. There was a relatively higher incidence of residual shunts and device migration in this series, generally due to the nonavailability of optimal device and surgical support. Long-term follow-up is required before we can draw conclusions with regard to the sustainability of drop in PA pressures. Septal Occluder devices may be a possible alternative for large tubular or window-type ducts with severe pulmonary hypertension, where there may be concerns about the size and stability of duct occluder devices.
Gebhardt, C; Gall, F P; Lux, G; Riemann, J; Link, W
1983-12-01
In patients with haemorrhagic necrotizing pancreatitis who are scheduled for surgery we have been carrying out a preoperative retrograde investigation of the pancreatic duct system for the past months. The results in, to date, ten patients revealed four different morphological findings of importance for the surgical tactic: 1. A normal pancreatic duct system with no signs of fistulae: only peripancreatic necrosectomy is required. - 2. Contrast medium leaks via a ductal fistula: left resection including the removal of the fistulous area must be done. - 3. Normal duct system with complete segmental parenchymal staining, representing total necrosis in this region: left resection of the pancreas. - 4. Duodenoscopically demonstrable perforation into the duodenum of a necrotic cavity in the head of the pancreas: conservative management only, no surgery, since this lesion resulting in drainage of the necrotic cavity into the bowel permits self-healing, while the site of the perforation within the necrotic wall cannot be dealt with by surgery. - The experience gained so far indicates that the surgical tactic can be determined with greater selectivity by the use of ERP.
NASA Technical Reports Server (NTRS)
Abbott, John M.; Anderson, Bernhard H.; Rice, Edward J.
1990-01-01
The internal fluid mechanics research program in inlets, ducts, and nozzles consists of a balanced effort between the development of computational tools (both parabolized Navier-Stokes and full Navier-Stokes) and the conduct of experimental research. The experiments are designed to better understand the fluid flow physics, to develop new or improved flow models, and to provide benchmark quality data sets for validation of the computational methods. The inlet, duct, and nozzle research program is described according to three major classifications of flow phenomena: (1) highly 3-D flow fields; (2) shock-boundary-layer interactions; and (3) shear layer control. Specific examples of current and future elements of the research program are described for each of these phenomenon. In particular, the highly 3-D flow field phenomenon is highlighted by describing the computational and experimental research program in transition ducts having a round-to-rectangular area variation. In the case of shock-boundary-layer interactions, the specific details of research for normal shock-boundary-layer interactions are described. For shear layer control, research in vortex generators and the use of aerodynamic excitation for enhancement of the jet mixing process are described.
Zhao, Zonghao; Bao, Lei; Yu, Xiaolan; Zhu, Chuanlong; Xu, Jing; Wang, Yu; Yin, Ming; Li, Yi; Li, Wenting
2017-09-01
Vanishing bile duct syndrome (VBDS) consists of a series of diseases characterized by the loss of >50% bile duct in portal areas. Many factors are associated with VBDS including infections, neoplasms, and drugs. Antibiotic is one of the most frequently reported causes of VBDS. A 29-year-old female was admitted because of liver injury for over 3 months. Tests for viruses that can cause hepatitis and autoantibodies were all negative. She was prescribed with antibiotics approximately a week before liver injury while there was no history of alcohol consumption. Liver biopsy demonstrated a loss of intrahepatic bile duct in most of the portal tracts. This patient was treated with ursodeoxycholic acid, polyene phosphatidylcholine, and bicyclol. Most importantly, the treatments in our hospital were proved by the ethics committee of Department of Infectious Disease, Anhui Provincial Hospital. The symptoms were improved. She is still under treatment. VBDS is rare but can be severe. A liver biopsy offers an important evidence for the diagnosis of VBDS, especially for those with a history of susceptible drugs taking.
Dominguez-Rosado, Ismael; Sanford, Dominic E; Liu, Jingxia; Hawkins, William G; Mercado, Miguel A
2016-09-01
Our goal was to determine the optimal timing for repair of bile duct injuries sustained during cholecystectomy. Bile duct injury during cholecystectomy is a serious complication that often requires surgical repair. There is heterogeneity in the literature regarding the optimal timing of surgical repair, and it remains unclear to what extent timing determines postoperative morbidity and long-term anastomotic function. A single institution prospective database was queried for all E1 to E4 injuries from 1989 to 2014 using a standardized tabular reporting format. Timing was stratified into 3 groups [early (<7 days), intermediate (8 days until 6 weeks), and late (>6 weeks) after injury]. Analysis was stratified between those who had a previous bile duct repair or not, including postoperative complications and anastomotic failure as outcome variables in 2 separate multivariate logistic regression models. There were 614 patients included in the study. The mean age was 41 years (range, 15-85 yrs), and the majority were female (80%). The mean follow-up time was 40.5 months. Side-to-side hepaticojejunostomy was performed in 94% of repairs. Intermediate repair was associated with a higher risk of postoperative complications [odd ratio = 3.7, 95% confidence interval (1.3-10.2), P = 0.01] when compared with early and late in those with a previous repair attempt. Sepsis control and avoidance of biliary stents were protective factors against anastomotic failure. Adequate sepsis control and delayed repair of biliary injuries should be considered for patients presenting between 8 days and 6 weeks after injury to prevent complications, if a previous bile duct repair was attempted.
An Assessment of Team Development at the Air Force Flight Dynamics Laboratory.
1980-09-01
FLIGHT DYNAMICS LABORATORY S. PERFORMING OG. REPORT NUMGER 7. AUTHOR(*) S. CONTRACT ON GRANT NUMBER(s) illiam D. Rutley, Captain, USAF _. PERFORMING ...the change from 1978 to 1980 on eleven criterion variables, employee job satisfaction, job motivation and absenteeism ; five organizational climate...variables except absenteeism . Absenteeism data were obtained from AFFDL intern~al records. The four main pro- duct divisions of AFlDL se.-ve-i as subjects
Preburner of Staged Combustion Rocket Engine
NASA Technical Reports Server (NTRS)
Yost, M. C.
1978-01-01
A regeneratively cooled LOX/hydrogen staged combustion assembly system with a 400:1 expansion area ratio nozzle utilizing an 89,000 Newton (20,000 pound) thrust regeneratively cooled thrust chamber and 175:1 tubular nozzle was analyzed, assembled, and tested. The components for this assembly include two spark/torch oxygen-hydrogen igniters, two servo-controlled LOX valves, a preburner injector, a preburner combustor, a main propellant injector, a regeneratively cooled combustion chamber, a regeneratively cooled tubular nozzle with an expansion area ratio of 175:1, an uncooled heavy-wall steel nozzle with an expansion area ratio of 400:1, and interconnecting ducting. The analytical effort was performed to optimize the thermal and structural characteristics of each of the new components and the ducting, and to reverify the capabilities of the previously fabricated components. The testing effort provided a demonstration of the preburner/combustor chamber operation, chamber combustion efficiency and stability, and chamber and nozzle heat transfer.
Service bay area, pump room level, showing ventilation fans and ...
Service bay area, pump room level, showing ventilation fans and ducts association with evaporative-cooling system. Note battery bank at far right. View to the east - Wellton-Mohawk Irrigation System, Pumping Plant No. 3, South of Interstate 8, Wellton, Yuma County, AZ
Are Ducted Mini-Splits Worth It?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jonathan M; Maguire, Jeffrey B; Metzger, Cheryn E.
Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within themore » Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).« less
An analysis code for the Rapid Engineering Estimation of Momentum and Energy Losses (REMEL)
NASA Technical Reports Server (NTRS)
Dechant, Lawrence J.
1994-01-01
Nonideal behavior has traditionally been modeled by defining efficiency (a comparison between actual and isentropic processes), and subsequent specification by empirical or heuristic methods. With the increasing complexity of aeropropulsion system designs, the reliability of these more traditional methods is uncertain. Computational fluid dynamics (CFD) and experimental methods can provide this information but are expensive in terms of human resources, cost, and time. This report discusses an alternative to empirical and CFD methods by applying classical analytical techniques and a simplified flow model to provide rapid engineering estimates of these losses based on steady, quasi-one-dimensional governing equations including viscous and heat transfer terms (estimated by Reynold's analogy). A preliminary verification of REMEL has been compared with full Navier-Stokes (FNS) and CFD boundary layer computations for several high-speed inlet and forebody designs. Current methods compare quite well with more complex method results and solutions compare very well with simple degenerate and asymptotic results such as Fanno flow, isentropic variable area flow, and a newly developed, combined variable area duct with friction flow solution. These solution comparisons may offer an alternative to transitional and CFD-intense methods for the rapid estimation of viscous and heat transfer losses in aeropropulsion systems.
[A domestic cat infected with a large number of Clonorchis sinensis].
Qiang, Chai; Xiao-Dong, Zhan; Chao-Pin, Li
2016-07-18
Adult Clonorchis sinensis not only occurs in human hepatic duct, but also in the liver, gallbladder and bile ducts of animals, including dogs and cats, thus causing clonorchiasis-one of important parasitic zoonoses. In present study, we dissected a domestic cat in which a total of 736 pieces of trematodes, identified as Clonorchis sinensis , were detected in the liver and cholecyst. The findings indicate that Clonorchis sinensis may be endemic in domestic animals in Wuhu area, and observe our awareness in prevention of the parasites in house pets.
Hepatic fascioliasis presenting with bile duct obstruction: a case report
Lefryekh, Rachid; Bensaad, Ahmed; Bensardi, Fatimazahra; Elhattabi, Khalid; Bouali, Mounir; Daif, Bessam; Fadil, Abdelaziz; Jaouhari, Zakaria; Hicham, Tazi; Hamdani, Aziz; Abdalaoui, Maha Soussi
2017-01-01
Fascioliasis is a zoonotic infection caused by a liver trematode: fasciola hepatica; which commonly affects cattle and sheep, humans are accidental hosts. Several cases have been reported in the literature worldwide with a large geographical distribution. We present a case of bile duct obstruction due to a hepatic fascioliasis, successfully treated with both a combined surgical and medical approaches. A high index of suspicion should be kept in mind for all cases of obstructive jaundice, especially in areas in which human fascioliasis infection is repeatedly reported. PMID:29158867
Hepatic fascioliasis presenting with bile duct obstruction: a case report.
Lefryekh, Rachid; Bensaad, Ahmed; Bensardi, Fatimazahra; Elhattabi, Khalid; Bouali, Mounir; Daif, Bessam; Fadil, Abdelaziz; Jaouhari, Zakaria; Hicham, Tazi; Hamdani, Aziz; Abdalaoui, Maha Soussi
2017-01-01
Fascioliasis is a zoonotic infection caused by a liver trematode: fasciola hepatica; which commonly affects cattle and sheep, humans are accidental hosts. Several cases have been reported in the literature worldwide with a large geographical distribution. We present a case of bile duct obstruction due to a hepatic fascioliasis, successfully treated with both a combined surgical and medical approaches. A high index of suspicion should be kept in mind for all cases of obstructive jaundice, especially in areas in which human fascioliasis infection is repeatedly reported.
Haack, Karla K. V.; Pollack, Brian P.; Millard-Stafford, Mindy; McCarty, Nael A.
2011-01-01
To understand potential mechanisms explaining interindividual variability observed in human sweat sodium concentration ([Na+]), we investigated the relationship among [Na+] of thermoregulatory sweat, plasma membrane expression of Na+ and Cl− transport proteins in biopsied human eccrine sweat ducts, and basal levels of vasopressin (AVP) and aldosterone. Lower ductal luminal membrane expression of the Cl− channel cystic fibrosis transmembrane conductance regulator (CFTR) was observed in immunofluorescent staining of sweat glands from healthy young adults identified as exceptionally “salty sweaters” (SS) (n = 6, P < 0.05) and from patients with cystic fibrosis (CF) (n = 6, P < 0.005) compared with ducts from healthy young adults with “typical” sweat [Na+] (control, n = 6). Genetic testing of healthy subjects did not reveal any heterozygotes (“carriers”) for any of the 39 most common disease-causing CFTR mutations in the United States. SS had higher baseline plasma [AVP] compared with control (P = 0.029). Immunostaining to investigate a potential relationship between higher plasma [AVP] (and sweat [Na+]) and ductal membrane aquaporin-5 revealed for all groups a relatively sparse and location-dependent ductal expression of the water channel with localization primarily to the secretory coil. Availability of CFTR for NaCl transport across the ductal membrane appears related to the significant physiological variability observed in sweat salt concentration in apparently healthy humans. At present, a heritable link between healthy salty sweaters and the most prevalent disease-causing CFTR mutations cannot be established. PMID:21228336
Mixing of Multiple Jets with a Confined Subsonic Crossflow in a Cylindrical Duct
NASA Technical Reports Server (NTRS)
Holdeman, James D.; Liscinsky, David S.; Samuelsen, G. Scott; Smith, Clifford E.; Oechsle, Victor L.
1996-01-01
This paper summarizes NASA-supported experimental and computational results on the mixing of a row of jets with a confined subsonic crossflow in a cylindrical duct. The studies from which these results were derived investigated flow and geometric variations typical of the complex 3-D flowfield in the combustion chambers in gas turbine engines. The principal observations were that the momentum-flux ratio and the number of orifices were significant variables. Jet penetration was critical, and jet penetration decreased as either the number of orifices increased or the momentum-flux ratio decreased. It also appeared that jet penetration remained similar with variations in orifice size, shape, spacing, and momentum-flux ratio when the number of orifices was proportional to the square-root of the momentum-flux ratio. In the cylindrical geometry, planar variances are very sensitive to events in the near wall region, so planar averages must be considered in context with the distributions. The mass-flow ratios and orifices investigated were often very large (mass-flow ratio greater than 1 and ratio of orifice area-to-mainstream cross-sectional area up to 0.5), and the axial planes of interest were sometimes near the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations. The results shown also seem to indicate that non-reacting dimensionless scalar profiles can emulate the reacting flow equivalence ratio distribution reasonably well. The results cited suggest that further study may not necessarily lead to a universal 'rule of thumb' for mixer design for lowest emissions, because optimization will likely require an assessment for a specific application.
Froman, D P; Rhoads, D D
2012-10-01
The objectives of the present work were 3-fold. First, a new method for estimating daily sperm production was validated. This method, in turn, was used to evaluate testis output as well as deferent duct throughput. Next, this analytical approach was evaluated in 2 experiments. The first experiment compared left and right reproductive tracts within roosters. The second experiment compared reproductive tract throughput in roosters from low and high sperm mobility lines. Standard curves were constructed from which unknown concentrations of sperm cells and sperm nuclei could be predicted from observed absorbance. In each case, the independent variable was based upon hemacytometer counts, and absorbance was a linear function of concentration. Reproductive tracts were excised, semen recovered from each duct, and the extragonadal sperm reserve determined by multiplying volume by sperm cell concentration. Testicular sperm nuclei were procured by homogenization of a whole testis, overlaying a 20-mL volume of homogenate upon 15% (wt/vol) Accudenz (Accurate Chemical and Scientific Corporation, Westbury, NY), and then washing nuclei by centrifugation through the Accudenz layer. Daily sperm production was determined by dividing the predicted number of sperm nuclei within the homogenate by 4.5 d (i.e., the time sperm with elongated nuclei spend within the testis). Sperm transit through the deferent duct was estimated by dividing the extragonadal reserve by daily sperm production. Neither the efficiency of sperm production (sperm per gram of testicular parenchyma per day) nor deferent duct transit differed between left and right reproductive tracts (P > 0.05). Whereas efficiency of sperm production did not differ (P > 0.05) between low and high sperm mobility lines, deferent duct transit differed between lines (P < 0.001). On average, this process required 2.2 and 1.0 d for low and high lines, respectively. In summary, we developed and then tested a method for quantifying male reproductive tract throughput. This method makes the study of semen production amenable to systems biology.
Development of a cylindrical diffusing optical fiber probe for pancreatic cancer therapy
NASA Astrophysics Data System (ADS)
Lee, Sangyeob; Park, Gaye; Park, Jihoon; Yu, Sungkon; Ha, Myungjin; Jang, Seulki; Ouh, Chihwan; Jung, Changhyun; Jung, Byungjo
2017-02-01
Although the patients with cancer on pancreas or pancreaticobiliary duct have been increased, it is very difficult to detect and to treat the pancreatic cancer because of its low accessibility and obtuseness. The pancreatic cancer has been diagnosed using ultrasonography, blood test, CT, endoscopic retrograde cholangiopancreatography (ERCP), endoscopic ultrasonography (EUS) and etc. Normally, light can be delivered to the target by optical fibers through the ERCP or EUS. Diffusing optical fibers have been developed with various methods. However, many of them have mechanical and biological problems in the use of small-bend-radius apparatus or in tissue area. This study developed a therapeutic cylindrical diffusing optical fiber probe (CDOFP) for ERCP and EUS which has moderate flexibility and solidity to treat the cancer on pancreaticobiliary duct or pancreas. The CDOFP consists of a biocompatible Teflon tube and multimode glass fiber which has diffusing area processed with laser and high refractive index resin. The CDOFP was characterized to investigate the clinical feasibility and other applications of light therapy using diffusing optical fiber. The results presented that the CDOFP may be used in clinic by combining with endoscopic method, such as ERCP or EUS, to treat cancer on pancreas and pancreaticobiliary duct.
Sera, Toshihiro; Yokota, Hideo; Tanaka, Gaku; Uesugi, Kentaro; Yagi, Naoto; Schroter, Robert C
2013-07-15
We visualized pulmonary acini in the core regions of the mouse lung in situ using synchrotron refraction-enhanced computed tomography (CT) and evaluated their kinematics during quasi-static inflation. This CT system (with a cube voxel of 2.8 μm) allows excellent visualization of not just the conducting airways, but also the alveolar ducts and sacs, and tracking of the acinar shape and its deformation during inflation. The kinematics of individual alveoli and alveolar clusters with a group of terminal alveoli is influenced not only by the connecting alveolar duct and alveoli, but also by the neighboring structures. Acinar volume was not a linear function of lung volume. The alveolar duct diameter changed dramatically during inflation at low pressures and remained relatively constant above an airway pressure of ∼8 cmH2O during inflation. The ratio of acinar surface area to acinar volume indicates that acinar distension during low-pressure inflation differed from that during inflation over a higher pressure range; in particular, acinar deformation was accordion-like during low-pressure inflation. These results indicated that the alveoli and duct expand differently as total acinar volume increases and that the alveolar duct may expand predominantly during low-pressure inflation. Our findings suggest that acinar deformation in the core regions of the lung is complex and heterogeneous.
Chang, Fei; Cheng, Dasheng; Qian, Mingyuan; Lu, Wei; Li, Huatao; Tang, Hongtai; Xia, Zhaofan
2016-10-11
BACKGROUND As patients with thoracic duct injuries often suffer from severe local soft tissue defects, integrated surgical treatment is needed to achieve damage repair and wound closure. However, thoracic duct chylous fistula is rare in burn patients, although it typically involves severe soft tissue damage in the neck or chest. CASE REPORT A 32-year-old male patient fell after accidentally contacting an electric current (380 V) and knocked over a barrel of sulfuric acid. The sulfuric acid continuously poured onto his left neck and chest, causing combined electrical and sulfuric acid burn injuries to his anterior and posterior torso, and various parts of his limbs (25% of his total body surface area). During treatment, chylous fistula developed in the left clavicular region, which we diagnosed as thoracic duct chylous fistula. We used diet control, intravenous nutritional support, and continuous somatostatin to reduce the chylous fistula output, and hydrophilic silver ion-containing dressings for wound coverage. A boneless muscle flap was used to seal the left clavicular cavity, and, integrated, these led to resolution of the chylous fistula. CONCLUSIONS Patients with severe electric or chemical burns in the neck or chest may be complicated with thoracic duct injuries. Although conservative treatment can control chylous fistula, wound cavity filling using a muscle flap is an effective approach for wound healing.
Aktas, Cevat; Kanter, Mehmet; Erboga, Mustafa; Mete, Rafet; Oran, Mustafa
2014-10-01
The goal of this study was to evaluate the possible protective effects of melatonin against cholestatic oxidative stress, liver damage and hepatocyte apoptosis in the common rats with bile duct ligation (BDL). A total of 24 male Wistar albino rats were divided into three groups: control, BDL and BDL + received melatonin; each group contains eight animals. Melatonin-treated BDL rats received daily melatonin 100 mg/kg/day via intraperitoneal injection. The application of BDL clearly increased the malondialdehyde (MDA) levels and decreased the superoxide dismutase (SOD) and glutathione (GSH) activities. Melatonin treatment significantly decreased the elevated tissue MDA levels and increased the reduced SOD and GSH enzyme levels in the tissues. The changes demonstrate that the bile duct proliferation and fibrosis in expanded portal tracts include the extension of proliferated bile ducts into lobules, mononuclear cells and neutrophil infiltration into the widened portal areas as observed in the BDL group. The data indicate that melatonin attenuates BDL-induced cholestatic liver injury, bile duct proliferation and fibrosis. The α-smooth muscle actin (α-SMA) and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL)-positive cells in the BDL were observed to be reduced with the melatonin treatment. These results suggest that administration of melatonin is a potentially beneficial agent to reduce liver damage in BDL by decreasing oxidative stress. © The Author(s) 2012.
Energy Management System Successful in Indiana Elementary School.
ERIC Educational Resources Information Center
School Business Affairs, 1984
1984-01-01
The new Oregon-Davis Elementary School in rural Indiana embodies state-of-the-art energy management. Its environmental systems include thorough insulation, dual heating and cooling equipment for flexible loads, and decentralized computer controls. A heat recovery unit and variable-air-volume discharge ducts also contribute to conservation. (MCG)
... to a blocked duct, a collection of pus (abscess) can develop in your breast and form a breast mass or area of firmness with thickening. An abscess usually requires surgical drainage. To avoid this complication, ...
Sedassari, Bruno T.; da Silva Lascane, Nelise A.; Tobouti, Priscila L.; Pigatti, Fernanda M.; Franco, Maria I.F.; de Sousa, Suzana C.O.M.
2014-01-01
Abstract Carcinoma ex pleomorphic adenoma (CXPA) is an unusual epithelial malignancy that develops from a primary or recurrent pleomorphic adenoma (PA), the most common tumor of salivary glands, and constitutes about 11.5% of all carcinomas that affect these glands. Intraoral minor salivary glands and seromucous glands of the oropharynx are uncommon locations of CXPA. On histopathological examination, the tumor comprises a wide morphological spectrum with a variable proportion between the benign and malignant components with the latter often predominating and overlapping the PA, which may cause misdiagnosis. Here, we report a case of palatal minor salivary gland CXPA composed of invasive micropapillary salivary duct carcinoma and adenoid cystic carcinoma components with multiple nodal metastases in a 74-year-old woman. Neoplastic cells showed heterogeneous immunohistochemical profile with both luminal and myoepithelial differentiation. The invasive micropapillary salivary duct carcinoma component demonstrated overexpression of the oncoprotein human epidermal growth factor receptor-2. This feature should be considered and evaluated as a possible target for adjuvant therapy in case of metastatic disease. PMID:25501054
Poirier, B; Ville, J M; Maury, C; Kateb, D
2009-09-01
An analytical three dimensional bicylindrical model is developed in order to take into account the effects of the saddle-shaped area for the interface of a n-Herschel-Quincke tube system with the main duct. Results for the scattering matrix of this system deduced from this model are compared, in the plane wave frequency domain, versus experimental and numerical data and a one dimensional model with and without tube length correction. The results are performed with a two-Herschel-Quincke tube configuration having the same diameter as the main duct. In spite of strong assumptions on the acoustic continuity conditions at the interfaces, this model is shown to improve the nonperiodic amplitude variations and the frequency localization of the minima of the transmission and reflection coefficients with respect to one dimensional model with length correction and a three dimensional model.
Prajapati, Parna; Shah, Pankhil; King, Hollis H; Williams, Arthur G; Desai, Pratikkumar; Downey, H Fred
2010-09-01
Osteopathic lymphatic pump treatments (LPT) are used to treat edema, but their direct effects on lymph flow have not been studied. In the current study, we examined the effects of LPT on lymph flow in the thoracic duct of instrumented conscious dogs in the presence of edema produced by constriction of the inferior vena cava (IVC). Six dogs were surgically instrumented with an ultrasonic flow transducer on the thoracic lymph duct and catheters in the descending thoracic aorta and in IVC. After postoperative recovery, lymph flow and hemodynamic variables were measured 1) pre-LPT, 2) during 4 min LPT, 3) post-LPT, in the absence and presence of edema produced by IVC constriction. This constriction increased abdominal girth from 60 +/-2.6 to 75 +/- 2.9 cm. Before IVC constriction, LPT increased lymph flow (P < 0.05) from 1.9 +/- 0.2 ml/min to a maximum of 4.7 +/-1.2 ml/min, whereas after IVC constriction, LPT increased lymph flow (P < 0.05) from 7.9 +/-2.2 to a maximum of 11.7 +/-2.2 ml/min. The incremental lymph flow mobilized by 4 min of LPT (ie, the flow that exceeded 4 min of baseline flow), was 10.6 ml after IVC constriction. This incremental flow was not significantly greater than that measured before IVC constriction. Edema caused by IVC constriction markedly increased lymph flow in the thoracic duct. LPT increased thoracic duct lymph flow before and after IVC constriction. The lymph flow mobilized by 4 min of LPT in presence of edema was not significantly greater than that mobilized prior to edema.
Tannuri, Ana Cristina A; Coelho, Maria Cecília M; de Oliveira Gonçalves, Josiane; Santos, Maria Mercês; Ferraz da Silva, Luiz Fernando; Bendit, Israel; Tannuri, Uenis
2012-03-01
The mechanisms of increased collagen production and liver parenchyma fibrosis are poorly understood. These phenomena are observed mainly in children with biliary obstruction (BO), and in a great number of patients, the evolution to biliary cirrhosis and hepatic failure leads to the need for liver transplantation before adolescence. However, pediatric liver transplantation presents with biliary complications in 20% to 30% of cases in the postoperative period. Intra- or extrahepatic stenosis of bile ducts is frequent and may lead to secondary biliary cirrhosis and the need for retransplantation. It is unknown whether biliary stenosis involving isolated segments or lobes may affect the adjacent nonobstructed lobes by paracrine or endocrine means, leading to fibrosis in this parenchyma. Therefore, the present study aimed to create an experimental model of selective biliary duct ligation in young animals with a subsequent evaluation of the histologic and molecular alterations in liver parenchyma of the obstructed and nonobstructed lobes. After a pilot study to standardize the surgical procedures, weaning rats underwent ligation of the bile ducts of the median, left lateral, and caudate liver lobes. The bile duct of the right lateral lobe was kept intact. To avoid intrahepatic biliary duct collaterals neoformation, the parenchymal connection between the right lateral and median lobes was clamped. The animals were divided into groups according to the time of death: 1, 2, 3, 4, and 8 weeks after surgical procedure. After death, the median and left lateral lobes (with BO) and the right lateral lobe (without BO [NBO]) were harvested separately. A group of 8 healthy nonoperated on animals served as controls. Liver tissues were subjected to histologic evaluation and quantification of the ductular proliferation and of the portal fibrosis. The expressions of smooth muscle α-actin (α-SMA), desmin, and transforming growth factor β1 genes were studied by molecular analyses (semiquantitative reverse transcriptase-polymerase chain reaction and real-time polymerase chain reaction, a quantitative method). Histologic analyses revealed the occurrence of ductular proliferation and collagen formation in the portal spaces of both BO and NBO lobes. These phenomena were observed later in NBO than BO. Bile duct density significantly increased 1 week after duct ligation; it decreased after 2 and 3 weeks and then increased again after 4 and 8 weeks in both BO and NBO lobes. The portal space collagen area increased after 2 weeks in both BO and NBO lobes. After 3 weeks, collagen deposition in BO was even higher, and in NBO, the collagen area started decreasing after 2 weeks. Molecular analyses revealed increased expression of the α-SMA gene in both BO and NBO lobes. The semiquantitative and quantitative methods showed concordant results. The ligation of a duct responsible for biliary drainage of the liver lobe promoted alterations in the parenchyma and in the adjacent nonobstructed parenchyma by paracrine and/or endocrine means. This was supported by histologic findings and increased expression of α-SMA, a protein related to hepatic fibrogenesis. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Allgood, Daniel C.; Graham, Jason S.; Ahuja, Vineet; Hosangadi, Ashvin
2010-01-01
Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively.
Flow design and simulation of a gas compression system for hydrogen fusion energy production
NASA Astrophysics Data System (ADS)
Avital, E. J.; Salvatore, E.; Munjiza, A.; Suponitsky, V.; Plant, D.; Laberge, M.
2017-08-01
An innovative gas compression system is proposed and computationally researched to achieve a short time response as needed in engineering applications such as hydrogen fusion energy reactors and high speed hammers. The system consists of a reservoir containing high pressure gas connected to a straight tube which in turn is connected to a spherical duct, where at the sphere’s centre plasma resides in the case of a fusion reactor. Diaphragm located inside the straight tube separates the reservoir’s high pressure gas from the rest of the plenum. Once the diaphragm is breached the high pressure gas enters the plenum to drive pistons located on the inner wall of the spherical duct that will eventually end compressing the plasma. Quasi-1D and axisymmetric flow formulations are used to design and analyse the flow dynamics. A spike is designed for the interface between the straight tube and the spherical duct to provide a smooth geometry transition for the flow. Flow simulations show high supersonic flow hitting the end of the spherical duct, generating a return shock wave propagating upstream and raising the pressure above the reservoir pressure as in the hammer wave problem, potentially giving temporary pressure boost to the pistons. Good agreement is revealed between the two flow formulations pointing to the usefulness of the quasi-1D formulation as a rapid solver. Nevertheless, a mild time delay in the axisymmetric flow simulation occurred due to moderate two-dimensionality effects. The compression system is settled down in a few milliseconds for a spherical duct of 0.8 m diameter using Helium gas and a uniform duct cross-section area. Various system geometries are analysed using instantaneous and time history flow plots.
Radtke, A; Sgourakis, G; Sotiropoulos, G C; Molmenti, E P; Nadalin, S; Fouzas, I; Schroeder, T; Saner, F H; Cicinnati, V R; Schenk, A; Malagó, M; Lang, H
2008-11-01
The peripheral intrahepatic biliary anatomy, especially at the sectorial level on the right side, has not been adequately described. The purpose of our study was to systematically describe this complex anatomy in clinically applicable fashion. We analyzed three-dimensional computed tomography (CT) imaging reconstructions of 139 potential living liver donors evaluated at our institution between January 2003 and June 2007. Eighty-nine (64%) donors had a normal right bile duct sectorial anatomy. In the other 50/139 (36%) cases, we observed abnormal sectorial branching patterns, with 45/50 abnormalities as trifurcations, whereas the remaining ones were quadrifurcations. In 22/50 (44%) abnormalities, a linear branching pattern (types B1/C1) and an early segmental origin off the right hepatic duct (types B3/C3) were present, a finding of particular danger when performing a right graft hepatectomy. In 2 cases, we noted a mixed type (B6/C6) of a rare complex anatomy. Our proposed classification of the right sectorial bile duct system clearly displays the "area at risk" encountered when performing right graft adult live donor liver transplantation and tumor resections involving the right lobe of the liver.
NASA Technical Reports Server (NTRS)
Whitlow, J. B., Jr.
1975-01-01
A parametric study was made of duct-burning turbofan and suppressed dry turbojet engines installed in a supersonic transport. A range of fan pressure ratios was considered for the separate-flow-fan engines. The turbofan engines were studied both with and without jet noise suppressors. Single- as well as dual-stream suppression was considered. Attention was concentrated on designs yielding sideline noises of FAR 36 (108 EPNdB) and below. Trades were made between thrust and wing area for a constant takeoff field length. The turbofans produced lower airplane gross weights than the turbojets at FAR 36 and below. The advantage for the turbofans increased as the sideline noise limit was reduced. Jet noise suppression, especially for the duct stream, was very beneficial for the turbofan engines as long as duct burning was permitted during takeoff. The maximum dry unsuppressed takeoff mode, however, yielded better results at extremely low noise levels. Noise levels as low as FAR 36-11 EPNdB were obtained with a turbofan in this takeoff mode, but at a considerable gross weight penalty relative to the best FAR 36 results.
Farrington, Robert B.; Anderson, Ren
2001-01-01
The cabin cooling system includes a cooling duct positioned proximate and above upper edges of one or more windows of a vehicle to exhaust hot air as the air is heated by inner surfaces of the windows and forms thin boundary layers of heated air adjacent the heated windows. The cabin cooling system includes at least one fan to draw the hot air into the cooling duct at a flow rate that captures the hot air in the boundary layer without capturing a significant portion of the cooler cabin interior air and to discharge the hot air at a point outside the vehicle cabin, such as the vehicle trunk. In a preferred embodiment, the cooling duct has a cross-sectional area that gradually increases from a distal point to a proximal point to the fan inlet to develop a substantially uniform pressure drop along the length of the cooling duct. Correspondingly, this cross-sectional configuration develops a uniform suction pressure and uniform flow rate at the upper edge of the window to capture the hot air in the boundary layer adjacent each window.
Genetics Home Reference: Alagille syndrome
... my area? Other Names for This Condition Alagille-Watson Syndrome Alagille's syndrome arteriohepatic dysplasia (AHD) cardiovertebral syndrome ... hypoplasia hepatofacioneurocardiovertebral syndrome paucity of interlobular bile ducts Watson-Miller syndrome Related Information How are genetic conditions ...
Performance Charts for the Turbojet Engine
NASA Technical Reports Server (NTRS)
Pinkel, Benjamin; Karp, Irving M.
1947-01-01
Charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet engine for any given set of operating conditions and component efficiencies. The effects of the pressure losses in the inlet duct and combustion chamber, the variation in the physical properties of the gas as it passes through the cycle, and the change in mass flow by the addition of fuel are included. The principle performance charts show the effects of the primary variables and correction charts provide the effects of the secondary variables.
Gas sampling system for reactive gas-solid mixtures
Daum, Edward D.; Downs, William; Jankura, Bryan J.; McCoury, Jr., John M.
1989-01-01
An apparatus and method for sampling a gas containing a reactive particulate solid phase flowing through a duct and for communicating a representative sample to a gas analyzer. A sample probe sheath 32 with an angular opening 34 extends vertically into a sample gas duct 30. The angular opening 34 is opposite the gas flow. A gas sampling probe 36 concentrically located within sheath 32 along with calibration probe 40 partly extend in the sheath 32. Calibration probe 40 extends further in the sheath 32 than gas sampling probe 36 for purging the probe sheath area with a calibration gas during calibration.
Gas sampling system for reactive gas-solid mixtures
Daum, Edward D.; Downs, William; Jankura, Bryan J.; McCoury, Jr., John M.
1990-01-01
An apparatus and method for sampling gas containing a reactive particulate solid phase flowing through a duct and for communicating a representative sample to a gas analyzer. A sample probe sheath 32 with an angular opening 34 extends vertically into a sample gas duct 30. The angular opening 34 is opposite the gas flow. A gas sampling probe 36 concentrically located within sheath 32 along with calibration probe 40 partly extends in the sheath 32. Calibration probe 40 extends further in the sheath 32 than gas sampling probe 36 for purging the probe sheath area with a calibration gas during calibration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco
A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.
New theory of uterovaginal embryogenesis.
Makiyan, Zograb
2016-01-02
The explanation of uterine and vaginal embryogenesis in humans still poses many controversies, because it is difficult to assess early stages of an embryo. The literature review revealed many disagreements in Mullerian theory, inciting some authors to propose new embryological hypotheses. In the original Mullerian theory: the paramesonephral ducts form the Fallopian tubes, uterus and vagina; the mesonephral ducts regress in female embryos. The aim of this article is to investigate the development of Mullerian ducts in humans, using comparative analysis of fundamental embryological theory and various utero-vaginal anomalies. Between 1998 and 2015, 434 patients with various uterovaginal malformations had been operated on at the Scientific Centre of Obstetrics Gynaecology and Perynatology in Moscow. The anatomies of the uterovaginal malformations in these patients were diagnosed with ultrasound and MRI and then verified during surgical correction by laparoscopy. A systematic comparison of uterovaginal malformations to those in the literature has allowed us to formulate a new theory of embryonic morphogenesis. The new theory is significantly different: ovary, ovarian ligamentum proprium, and ligamentum teres uteri derive from gonadal ridges; Fallopian tubes and vagina completely develop from mesonephral ducts. The uterus develops in the area of intersection between the mesonephral ducts with gonadal ridges by the fusion of the two. The new theory may to induce future embryological studies. The hypothetic possibility that the ovary and endometrium derive from the gonadal ridges could be the key to understanding the enigmatic aetiologies of extragenital and ovarian endometriosis.
Gupta, Deepak Prasad; Hwang, Jae-Won; Cho, Eui-Sic; Kim, Won; Song, Chang Ho; Chai, Ok Hee
2017-01-01
Sonic Hedgehog (Shh) signaling plays a major role in and is essential for regulation, patterning, and proliferation during renal development. Smoothened (Smo) plays a pivot role in transducing the Shh-glioma-associated oncogene Kruppel family member. However, the cellular and molecular mechanism underlying the role of sustained Smo activation in postnatal kidney development is still not clearly understood. Using a conditional knockin mouse model that expresses a constitutively activated form of Smo (SmoM2) upon Homeobox-B7-mediated recombination (Hoxb7-Cre), the effects of Shh signaling were determined in postnatal kidney development. SmoM2;Hoxb7-Cre mutant mice showed growth retardation with a reduction of body weight. Constitutive activation of Smo in the renal collecting ducts caused renal hypoplasia, hydronephrosis, and hydroureter. The parenchymal area and glomerular numbers were reduced, but the glomerular density was increased in SmoM2;Hoxb7-Cre mutant mice. The expression of Patched 1, the receptor of Shh and a downstream target gene of the Shh signaling pathway, was highly restricted and it was upregulated in the inner medullary collecting ducts of the kidney. The proliferative cells in the mesenchyme and collecting ducts were decreased in SmoM2;Hoxb7-Cre mutant mice. This study showed for the first time that sustained Smo inhibits postnatal kidney development by suppressing the proliferation of the mesenchyme and medullary collecting ducts in mice. © 2017 S. Karger AG, Basel.
Ignition and Performance Tests of Rocket-Based Combined Cycle Propulsion System
NASA Technical Reports Server (NTRS)
Anderson, William E.
2005-01-01
The ground testing of a Rocket Based Combined Cycle engine implementing the Simultaneous Mixing and Combustion scheme was performed at the direct-connect facility of Purdue University's High Pressure Laboratory. The fuel-rich exhaust of a JP-8/H2O2 thruster was mixed with compressed, metered air in a constant area, axisymmetric duct. The thruster was similar in design and function to that which will be used in the flight test series of Dryden's Ducted-Rocket Experiment. The determination of duct ignition limits was made based on the variation of secondary air flow rates and primary thruster equivalence ratios. Thrust augmentation and improvements in specific impulse were studied along with the pressure and temperature profiles of the duct to study mixing lengths and thermal choking. The occurrence of ignition was favored by lower rocket equivalence ratios. However, among ignition cases, better thrust and specific impulse performance were seen with higher equivalence ratios owing to the increased fuel available for combustion. Thrust and specific impulse improvements by factors of 1.2 to 1.7 were seen. The static pressure and temperature profiles allowed regions of mixing and heat addition to be identified. The mixing lengths were found to be shorter at lower rocket equivalence ratios. Total pressure measurements allowed plume-based calculation of thrust, which agreed with load-cell measured values to within 6.5-8.0%. The corresponding Mach Number profile indicated the flow was not thermally choked for the highest duct static pressure case.
30 CFR 57.4504 - Fan installations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for main and booster fans, and air ducts connecting main fans to underground openings shall be constructed of noncombustible materials. (b) Areas within 25 feet of main fans or booster fans shall be free...
30 CFR 57.4504 - Fan installations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for main and booster fans, and air ducts connecting main fans to underground openings shall be constructed of noncombustible materials. (b) Areas within 25 feet of main fans or booster fans shall be free...
30 CFR 57.4504 - Fan installations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for main and booster fans, and air ducts connecting main fans to underground openings shall be constructed of noncombustible materials. (b) Areas within 25 feet of main fans or booster fans shall be free...
30 CFR 57.4504 - Fan installations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for main and booster fans, and air ducts connecting main fans to underground openings shall be constructed of noncombustible materials. (b) Areas within 25 feet of main fans or booster fans shall be free...
NASA contributions to radial turbine aerodynamic analyses
NASA Technical Reports Server (NTRS)
Glassman, A. J.
1980-01-01
A brief description of the radial turbine and its analysis needs is followed by discussions of five analytical areas; design geometry and performance, off design performance, blade row flow, scroll flow, and duct flow. The functions of the programs, areas of applicability, and limitations and uncertainties are emphasized. Both past contributions and current activities are discussed.
Looking southwest in the service bay area, pump room level, ...
Looking southwest in the service bay area, pump room level, at the ventilation fan ducts associated with the evaporative cooling system. Stairs to the operating deck above the intakes are at the far left - Wellton-Mohawk Irrigation System, Pumping Plant No. 2, Bounded by Interstate 8 to south, Wellton, Yuma County, AZ
Closeup view of the bottom area of Space Shuttle Main ...
Close-up view of the bottom area of Space Shuttle Main Engine (SSME) 2052 engine assembly mounted in a SSME Engine Handler in the Horizontal Processing area of the SSME Processing Facility at Kennedy Space Center. The most prominent features in this view are the Low-Pressure Oxidizer Discharge Duct toward the bottom of the assembly, the SSME Engine Controller and the Main Fuel Valve Hydraulic Actuator are in the approximate center of the assembly in this view, the Low-Pressure Fuel Turbopump (LPFTP), the LPFTP Discharge Duct are to the left on the assembly in this view and the High-Pressure Fuel Turbopump is located toward the top of the engine assembly in this view. The ring of tabs in the right side of the image, at the approximate location of the Nozzle and the Coolant Outlet Manifold interface is the Heat Shield Support Ring. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
Turbofan noise generation. Volume 2: Computer programs
NASA Technical Reports Server (NTRS)
Ventres, C. S.; Theobald, M. A.; Mark, W. D.
1982-01-01
The use of a package of computer programs developed to calculate the in duct acoustic mods excited by a fan/stator stage operating at subsonic tip speed is described. The following three noise source mechanisms are included: (1) sound generated by the rotor blades interacting with turbulence ingested into, or generated within, the inlet duct; (2) sound generated by the stator vanes interacting with the turbulent wakes of the rotor blades; and (3) sound generated by the stator vanes interacting with the velocity deficits in the mean wakes of the rotor blades. The computations for three different noise mechanisms are coded as three separate computer program packages. The computer codes are described by means of block diagrams, tables of data and variables, and example program executions; FORTRAN listings are included.
Turbofan noise generation. Volume 2: Computer programs
NASA Astrophysics Data System (ADS)
Ventres, C. S.; Theobald, M. A.; Mark, W. D.
1982-07-01
The use of a package of computer programs developed to calculate the in duct acoustic mods excited by a fan/stator stage operating at subsonic tip speed is described. The following three noise source mechanisms are included: (1) sound generated by the rotor blades interacting with turbulence ingested into, or generated within, the inlet duct; (2) sound generated by the stator vanes interacting with the turbulent wakes of the rotor blades; and (3) sound generated by the stator vanes interacting with the velocity deficits in the mean wakes of the rotor blades. The computations for three different noise mechanisms are coded as three separate computer program packages. The computer codes are described by means of block diagrams, tables of data and variables, and example program executions; FORTRAN listings are included.
NASA Technical Reports Server (NTRS)
Cole, G. L.; Neiner, G. H.; Baumbick, R. J.
1973-01-01
Experimental results of terminal shock and restart control system tests of a two-dimensional, twin-duct mixed compression inlet are presented. High-response (110-Hz bandwidth) overboard bypass doors were used, both as the variable to control shock position and as the means of disturbing the inlet airflow. An inherent instability in inlet shock position resulted in noisy feedback signals and thus restricted the terminal shock position control performance that was achieved. Proportional-plus-integral type controllers using either throat exit static pressure or shock position sensor feedback gave adequate low-frequency control. The inlet restart control system kept the terminal shock control loop closed throughout the unstart-restart transient. The capability to restart the inlet was non limited by the inlet instability.
An Experimental Investigation of the Design Variables for NACA Submerged Duct Entrances
1948-01-08
M08111aD and Lauroe N. BaDdall . ~mrmil7\\5, . Intonation concern1ng the ~tere and design Tar1ablee attect1ne an IACA eubmerged duct dee1gn ia preeented...bOUD4a1-l&7er thickneea ot tD.e .urtace..1nto vbich the Wet ia placed~ tOUDd to ha.... a larse ettect 011 the p"••ure r8C0Te17. Fbo8ible applications ot...8217~ ".~., ." ’. ., . .." . . j I • , • " ’" • ~~. • 11 " , ,\\".. • " ’: ;> f ~,. .. \\. .~••i ’ j. 1nle~elocit:r ratio Subsoripts o tree streaa 1 duot-«ltranoe statIon .2
Wu, Yuan; Li, Haili; Tang, Yun; Yan, Xiaoming
2017-03-01
To compare, in vivo, differences in meibomian gland morphology between children and adolescents. Sixty-nine patients were included in this study and divided into two groups: children (n = 31; age range: 3 to 11 years) and adolescents (n = 39; age range: 12 to 18 years). Images of meibomian glands were obtained by infrared meibography and analyzed using ImageJ software (developed by the National Institutes of Health; available at http://rsb.info.nih.gov/ij/download.html). Meibomian gland loss, the number of meibomian gland ducts, the relative width of the meibomian gland ducts, and the percent area of the meibomian gland acini were compared between the two groups. Meibomian gland loss was found in both groups, but the meiboscore was not significantly different between the two groups (0.35 ± 0.6 vs 0.41 ± 0.8, t = -0.314, P > .05). The number of meibomian gland ducts (25.85 ± 3.25 vs 23.23 ± 3.06, t = -3.437, P < .05), relative width of the meibomian gland ducts (69.62% ± 5% vs 66.1% ± 7%, t = -2.454, P < .05), and percent area of the meibomian gland acini (57.7% ± 4% vs 55.5% ± 4%, t = 2.571, P < .05) in the upper eyelid were significantly greater in adolescents than in children. However, no significant differences were found in the lower eyelid between the two groups. Meibography is useful for the assessment of ocular surface conditions in children and adolescents. Meibomian gland loss occurs in both children and adolescents. The meibomian glands of the upper eyelid exhibit more morphological changes in adolescents than in children. [J Pediatr Ophthalmol Strabismus. 2017;54(2):78-83.]. Copyright 2017, SLACK Incorporated.
Constructal vascularized structures
NASA Astrophysics Data System (ADS)
Cetkin, Erdal
2015-06-01
Smart features such as self-healing and selfcooling require bathing the entire volume with a coolant or/and healing agent. Bathing the entire volume is an example of point to area (or volume) flows. Point to area flows cover all the distributing and collecting kinds of flows, i.e. inhaling and exhaling, mining, river deltas, energy distribution, distribution of products on the landscape and so on. The flow resistances of a point to area flow can be decreased by changing the design with the guidance of the constructal law, which is the law of the design evolution in time. In this paper, how the flow resistances (heat, fluid and stress) can be decreased by using the constructal law is shown with examples. First, the validity of two assumptions is surveyed: using temperature independent Hess-Murray rule and using constant diameter ducts where the duct discharges fluid along its edge. Then, point to area types of flows are explained by illustrating the results of two examples: fluid networks and heating an area. Last, how the structures should be vascularized for cooling and mechanical strength is documented. This paper shows that flow resistances can be decreased by morphing the shape freely without any restrictions or generic algorithms.
25. BUILDING NO. 527, DEHYDRATING HOUSE, DETAIL OF SOLVENT RECOVERY ...
25. BUILDING NO. 527, DEHYDRATING HOUSE, DETAIL OF SOLVENT RECOVERY DUCTS. SOUTH SIDE OF BUILDING. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1991-01-01
Experimental and computational results on the mixing of single, double, and opposed rows of jets with an isothermal or variable temperature mainstream in a confined subsonic crossflow are summarized. The studies were performed to investigate flow and geometric variations typical of the complex 3-D flowfield in the dilution zone of combustion chambers in gas turbine engines. The principal observations from the experiments were that the momentum-flux ratio was the most significant flow variable, and that temperature distributions were similar (independent of orifice diameter) when the orifice spacing and the square-root of the momentum-flux ratio were inversely proportional. The experiments and empirical model for the mixing of a single row of jets from round holes were extended to include several variations typical of gas turbine combustors. Combinations of flow and geometry that gave optimum mixing were identified from the experimental results. Based on results of calculations made with a 3-D numerical model, the empirical model was further extended to model the effects of curvature and convergence. The principle conclusions from this study were that the orifice spacing and momentum-flux relationships were the same as observed previously in a straight duct, but the jet structure was significantly different for jets injected from the inner wall wall of a turn than for those injected from the outer wall. Also, curvature in the axial direction caused a drift of the jet trajectories toward the inner wall, but the mixing in a turning and converging channel did not seem to be inhibited by the convergence, independent of whether the convergence was radial or circumferential. The calculated jet penetration and mixing in an annulus were similar to those in a rectangular duct when the orifice spacing was specified at the radius dividing the annulus into equal areas.
USDA-ARS?s Scientific Manuscript database
Visualizing areas of tissue that are occupied by air or liquid can provide a unique perspective on the relationships between various spaces within the tissue. The portal tracts of liver tissue are an example of such a space since the liver contains several vessels and ducts in various patterns of i...
Wither the Jasmine: China’s Two-Phase Operation for Cyber Control-in-Depth
2012-01-01
issued a directive requesting all websites to “con- duct strict searches of interactive spaces such as online forums, blogs, micro - blogs, instant message...February 2011, the area in front of the Wangfujing McDonald’s was sealed off with signs saying that the area was under construction due to sinking pavement
Investigation of the sound generation mechanisms for in-duct orifice plates.
Tao, Fuyang; Joseph, Phillip; Zhang, Xin; Stalnov, Oksana; Siercke, Matthias; Scheel, Henning
2017-08-01
Sound generation due to an orifice plate in a hard-walled flow duct which is commonly used in air distribution systems (ADS) and flow meters is investigated. The aim is to provide an understanding of this noise generation mechanism based on measurements of the source pressure distribution over the orifice plate. A simple model based on Curle's acoustic analogy is described that relates the broadband in-duct sound field to the surface pressure cross spectrum on both sides of the orifice plate. This work describes careful measurements of the surface pressure cross spectrum over the orifice plate from which the surface pressure distribution and correlation length is deduced. This information is then used to predict the radiated in-duct sound field. Agreement within 3 dB between the predicted and directly measured sound fields is obtained, providing direct confirmation that the surface pressure fluctuations acting over the orifice plates are the main noise sources. Based on the developed model, the contributions to the sound field from different radial locations of the orifice plate are calculated. The surface pressure is shown to follow a U 3.9 velocity scaling law and the area over which the surface sources are correlated follows a U 1.8 velocity scaling law.
Acoustic propagation in curved ducts with extended reacting wall treatment
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.
1989-01-01
A finite-element Galerkin formulation was employed to study the attenuation of acoustic waves propagating in two-dimensional S-curved ducts with absorbing walls without a mean flow. The reflection and transmission at the entrance and the exit of a curved duct were determined by coupling the finite-element solutions in the curved duct to the eigenfunctions of an infinite, uniform, hard wall duct. In the frequency range where the duct height and acoustic wave length are nearly equal, the effects of duct length, curvature (duct offset) and absorber thickness were examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. A means of reducing the number of elements in the absorber region was also presented. In addition, for a curved duct, power attenuation contours were examined to determine conditions for maximum acoustic power absorption. Again, wall curvature was found to significantly effect the optimization process.
Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munk, Jeffrey D; Gehl, Anthony C; Jackson, Roderick K
2012-04-01
Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were comparedmore » during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.« less
[Vascular relationships of the right great splanchnic nerve in the thorax].
Ndoye, J-M; Hamel, O; Hamel, A; Ploteau, S; Armstrong, O; Le Borgne, J; Rogez, J-M; Robert, R
2015-12-01
The surgical assumption of responsibility of the pancreatic pain requires either a truncular coelioscopic or radicular neurectomy of greater splanchnic nerves (gsn). The goal of our work is to describe the way and relations of the right gsn which are variable and rarely described. This constitutes an undeniable peroperational hemorrhagic risk during splanchnicectomy. After a double side thoracotomy and a bilateral sterno-clavicular desarticulation on 15 adult cadaveric subjects preserved by method of Winckler we removed the sterno-costal drill plate as well as the ventral rib arch and proceeded to a mediastinal evisceration of the thorax. Then we respected only the thoracic aorta and the oesophagus, the azygos venous system, the thoracic duct and the thoracic sympathetic chain. In some of the subjects, the azygos vein was injected (after catheterization of its stick) using gelatine coloured with blue paint. We studied the way and vascular relations of the right gsn. We measured the transverse distances between the origin of the gsn on one hand and the longitudinal axes of the azygos vein and the thoracic duct on the other hand. The relations of the right gsn trunk during its way related to the azygos vein in particular its constitutive origin and its affluents: ascending lumbar vein and twelfth intercostal vein. Sometimes the thoracic duct even a lymphatic node was near the gsn in the posterior infra-mediastinal space. A classification of the way and vascular relations of the right gsn in the thorax identified 3 anatomical types. The average distances separating the right gsn on one hand from the azygos vein and the thoracic duct on the other hand were respectively 5.7 mm and 11.2 mm. The vascular relations of the right gsn are very variable from one subject to another but primarily venous, sometimes lymphatic. They concerned the great thoracic vessels whose respect is essential in particular at the time of mini-invasive access procedure for a cœlioscopic splanchnicectomy. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Electromagnetic propagation in PEC and absorbing curved S-ducts
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.
1988-01-01
A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.
Transition duct assembly with modified trailing edge in turbine system
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMahan, Kevin Weston; Schott, Carl Gerard; Ingram, Clint Luigie
2016-10-04
Transition duct assemblies for turbine systems and turbomachines are provided. In one embodiment, a transition duct assembly includes a plurality of transition ducts disposed in a generally annular array and comprising a first transition duct and a second transition duct. Each of the plurality of transition ducts includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of each transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct assembly further includes anmore » aerodynamic structure defined by the passages of the first transition duct and the second transition duct. The aerodynamic structure includes a pressure side, a suction side, and a trailing edge, the trailing edge having a modified aerodynamic contour.« less
Combustor assembly in a gas turbine engine
Wiebe, David J; Fox, Timothy A
2013-02-19
A combustor assembly in a gas turbine engine. The combustor assembly includes a combustor device coupled to a main engine casing, a first fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner disposed radially inwardly from the flow sleeve. The first fuel injection system provides fuel that is ignited with the pressurized air creating first working gases. The intermediate duct is disposed between the liner and the transition duct and defines a path for the first working gases to flow from the liner to the transition duct. An intermediate duct inlet portion is associated with a liner outlet and allows movement between the intermediate duct and the liner. An intermediate duct outlet portion is associated with a transition duct inlet section and allows movement between the intermediate duct and the transition duct.
Shera, Christopher A.
2014-01-01
Parent and Allen [(2007). J. Acoust. Soc. Am. 122, 918–931] introduced the “method of lumens” to compute the plane-wave reflectance in a duct terminated with a nonuniform impedance. The method involves splitting the duct into multiple, fictitious subducts (lumens), solving for the reflectance in each subduct, and then combining the results. The method of lumens has considerable intuitive appeal and is easily implemented in the time domain. Previously applied only in a complex acoustical setting where proper evaluation is difficult (i.e., in a model of the ear canal and tympanic membrane), the method is tested here by using it to compute the reflectance from an area constriction in an infinite lossless duct considered in the long-wavelength limit. Neither the original formulation of the method—shown here to violate energy conservation except when the termination impedance is uniform—nor a reformulation consistent with basic physical constraints yields the correct solution to this textbook problem in acoustics. The results are generalized and the nature of the errors illuminated. PMID:25480060
Modeling Vortex Generators in the Wind-US Code
NASA Technical Reports Server (NTRS)
Dudek, Julianne C.
2010-01-01
A source term model which simulates the effects of vortex generators was implemented into the Wind-US Navier Stokes code. The source term added to the Navier-Stokes equations simulates the lift force which would result from a vane-type vortex generator in the flowfield. The implementation is user-friendly, requiring the user to specify only three quantities for each desired vortex generator: the range of grid points over which the force is to be applied and the planform area and angle of incidence of the physical vane. The model behavior was evaluated for subsonic flow in a rectangular duct with a single vane vortex generator, supersonic flow in a rectangular duct with a counterrotating vortex generator pair, and subsonic flow in an S-duct with 22 co-rotating vortex generators. The validation results indicate that the source term vortex generator model provides a useful tool for screening vortex generator configurations and gives comparable results to solutions computed using a gridded vane.
Characterization of the secondary flow in hexagonal ducts
NASA Astrophysics Data System (ADS)
Marin, O.; Vinuesa, R.; Obabko, A. V.; Schlatter, P.
2016-12-01
In this work we report the results of DNSs and LESs of the turbulent flow through hexagonal ducts at friction Reynolds numbers based on centerplane wall shear and duct half-height Reτ,c ≃ 180, 360, and 550. The evolution of the Fanning friction factor f with Re is in very good agreement with experimental measurements. A significant disagreement between the DNS and previous RANS simulations was found in the prediction of the in-plane velocity, and is explained through the inability of the RANS model to properly reproduce the secondary flow present in the hexagon. The kinetic energy of the secondary flow integrated over the cross-sectional area
Characterization of the secondary flow in hexagonal ducts
Marin, O.; Vinuesa, R.; Obabko, A. V.; ...
2016-12-06
In this work we report the results of DNSs and LESs of the turbulent flow through hexagonal ducts at friction Reynolds numbers based on centerplane wall shear and duct half-height Re τ,c ≃ 180, 360, and 550. The evolution of the Fanning friction factor f with Re is in very good agreement with experimental measurements. A significant disagreement between the DNS and previous RANS simulations was found in the prediction of the in-plane velocity, and is explained through the inability of the RANS model to properly reproduce the secondary flow present in the hexagon. The kinetic energy of the secondarymore » flow integrated over the cross-sectional area < K > yz decreases with Re in the hexagon, whereas it remains constant with Re in square ducts at comparable Reynolds numbers. Close connection between the values of Reynolds stress uw¯ on the horizontal wall close to the corner and the interaction of bursting events between the horizontal and inclined walls is found. This interaction leads to the formation of the secondary flow, and is less frequent in the hexagon as Re increases due to the 120° aperture of its vertex, whereas in the square duct the 90° corner leads to the same level of interaction with increasing Re. Analysis of turbulence statistics at the centerplane and the azimuthal variance of the mean flow and the fluctuations shows a close connection between hexagonal ducts and pipe flows, since the hexagon exhibits near-axisymmetric conditions up to a distance of around 0.15 DH measured from its center. Spanwise distributions of wall-shear stress show that in square ducts the 90° corner sets the location of a high-speed streak at a distance z + v≃50 from it, whereas in hexagons the 120° aperture leads to a shorter distance of z + v≃38. Finally, at these locations the root mean square of the wall-shear stresses exhibits an inflection point, which further shows the connections between the near-wall structures and the large-scale motions in the outer flow.« less
Paracellular transport in the collecting duct
Hou, Jianghui
2016-01-01
Purpose of review The paracellular pathway through the tight junction provides an important route for chloride reabsorption in the collecting duct of the kidney. This review describes recent findings of how defects in paracellular chloride permeation pathway may cause kidney diseases and how such a pathway may be regulated to maintain normal chloride homeostasis. Recent findings The tight junction in the collecting duct expresses two important claudin genes – claudin-4 and claudin-8. Transgenic knockout of either claudin gene causes hypotension, hypochloremia, and metabolic alkalosis in experimental animals. The claudin-4 mediated chloride permeability can be regulated by a protease endogenously expressed by the collecting duct cell – Cap1. Cap1 regulates the intercellular interaction of claudin-4 and its membrane stability. KLHL3, previously identified as a causal gene for Gordon’s syndrome, also known as pseudohypoaldosteronism II (PHA-II), directly interacts with claudin-8 and regulates its ubiquitination and degradation. The dominant PHA-II mutation (R528H) in KLHL3 abolishes claudin-8 binding, ubiquitination, and degradation. Summary The paracellular chloride permeation pathway in the kidney is an important but understudied area in nephrology. It plays vital roles in renal salt handling and regulation of extracellular fluid volume and blood pressure. Two claudin proteins – claudin-4 and claudin-8 contribute to the function of this paracellular pathway. Deletion of either claudin protein from the collecting duct causes renal chloride reabsorption defects and low blood pressure. Claudins can be regulated on post-translational levels by several mechanisms involving protease and ubiquitin ligase. Deregulation of claudins may cause human hypertension as exemplified in the Gordon’s syndrome. PMID:27490784
A Model for Shear Layer Effects on Engine Noise Radiation
NASA Technical Reports Server (NTRS)
Nark, Douglas M.; Farassat, F.; Pope, D. Stuart; Vatsa, V.
2004-01-01
Prediction of aircraft engine noise is an important aspect of addressing the issues of community noise and cabin noise control. The development of physics based methodologies for performing such predictions has been a focus of Computational Aeroacoustics (CAA). A recent example of code development in this area is the ducted fan noise propagation and radiation code CDUCT-LaRC. Included within the code is a duct radiation model that is based on the solution of FfowcsWilliams-Hawkings (FW-H) equation with a penetrable data surface. Testing of this equation for many acoustic problems has shown it to provide generally better results than the Kirchhoff formula for moving surfaces. Currently, the data surface is taken to be the inlet or exhaust plane for inlet or aft-fan cases, respectively. While this provides reasonable results in many situations, these choices of data surface location lead to a few limitations. For example, the shear layer between the bypass ow and external stream can refract the sound waves radiated to the far field. Radiation results can be improved by including this effect, as well as the rejection of the sound in the bypass region from the solid surface external to the bypass duct surrounding the core ow. This work describes the implementation, and possible approximation, of a shear layer boundary condition within CDUCT-LaRC. An example application also illustrates the improvements that this extension offers for predicting noise radiation from complex inlet and bypass duct geometries, thereby providing a means to evaluate external treatments in the vicinity of the bypass duct exhaust plane.
Turbofan aft duct suppressor study program listing and user's guide
NASA Technical Reports Server (NTRS)
Joshi, M. C.; Kraft, R. E.
1983-01-01
A description of the structure of the Annular Flow Duct Program (AFDP) for the calculation of acoustic suppression due to treatment in a finite length annular duct carrying sheared flow is presented. Although most appropriate for engine exhaust ducts, this program can be used to study sound propagation in any duct that maintains annular geometry over a considerable length of the duct. The program is based on the modal analysis of sound propagation in ducts with axial segments of different wall impedances. For specified duct geometry, wall impedance, flow and acoustic conditions in the duct (including mode amplitude distribution of the source) and duct termination reflection characteristics, the program calculates the suppression due to the treatment in the duct. The presence of forward and backward traveling modes in the duct due to the reflection and redistribution of modes at segment interfaces and duct end terminations are taken into account in the calculations. The effects of thin wall boundary layers (with a linear or mean flow velocity profile) on the acoustic propagation are also included in the program. A functional description of the major subroutines is included and a sample run is provided with an explanation of the output.
14 CFR 29.1103 - Induction systems ducts and air duct systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct...
14 CFR 25.1103 - Induction system ducts and air duct systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction system ducts and air duct systems. 25.1103 Section 25.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Induction System § 25.1103 Induction system ducts and air duct...
Nath, Debashis; Chen, Wen; Graf, Hans-F; Lan, Xiaoqiang; Gong, Hainan
2017-09-20
Upper tropospheric equatorial westerly ducts over the Pacific Ocean are the preferred location for Rossby wave breaking events during boreal winter and spring. These subtropical wave breaking events lead to the intrusion of high PV (potential vorticity) air along the extra-tropical tropopause and transport ozone rich dry stratospheric air into the tropics. The intrusion frequency has strong interannual variability due to ENSO (El-Niño/Southern Oscillation), with more events under La-Niña and less under El-Niño conditions. This may result from stronger equatorial westerly ducts and subtropical jets during La-Niña and weaker during El-Niño. It was previously suggested that the interannual variability of the tropospheric ozone distribution over the central-eastern Pacific Ocean is mainly driven by convective activity related to ENSO and that the barotropic nature of the subtropical intrusions restricts the tracers within the UT. However, our analysis shows that tropospheric ozone concentration and subtropical intrusions account ~65% of the co- variability (below 5 km) in the outer tropical (10-25°N) central Pacific Ocean, particularly during La-Niña conditions. Additionally, we find a two-fold increase and westward shift in the intrusion frequency over the Pacific Ocean, due to the climate regime shift in SST pattern during 1997/98.
Proctor, John P.
2001-02-27
A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.
Proctor, John P.; deKieffer, Robert C.
2001-01-01
A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.
Parametric study of electromagnetic waves propagating in absorbing curved S ducts
NASA Technical Reports Server (NTRS)
Baumeister, Kenneth J.
1989-01-01
A finite-element Galerkin formulation has been developed to study attenuation of transverse magnetic (TM) waves propagating in two-dimensional S-curved ducts with absorbing walls. In the frequency range where the duct diameter and electromagnetic wave length are nearly equal, the effect of duct length, curvature (duct offset), and absorber wall thickness was examined. For a given offset in the curved duct, the length of the S-duct was found to significantly affect both the absorptive and reflective characteristics of the duct. For a straight and a curved duct with perfect electric conductor terminations, power attenuation contours were examined to determine electromagnetic wall properties associated with maximum input signal absorption. Offset of the S-duct was found to significantly affect the value of the wall permittivity associated with the optimal attenuation of the incident electromagnetic wave.
Slanted baffle mist eliminator
Vance, Richard F.
1995-11-07
An apparatus for the elimination of mist from off-gas during vitrification f nuclear waste, where baffles are installed on a slant toward the flow of the off-gasses eliminating the need to expand the cross-sectional area of the duct size.
Miller, Anne; Hong, Matthew K-H; Hutson, John M
2004-04-01
The broad ligament is a double fold of peritoneum forming a mesentery for the human female genital tract. We investigated the anatomy of the broad ligament in different species and its hormonal regulation to determine if it had a role in gonadal positioning. The medical and veterinary literature was reviewed for descriptions of broad ligament anatomy and development. In addition, four adult female rats were dissected to compare the macroscopic anatomy of the broad ligament with any homologous structures in the male (n = 2). Detailed review was made of human males with persistent Müllerian duct syndrome (PMDS) and of bovine freemartin calves to determine the effect of abnormal hormonal environments on broad ligament development. Human and veterinary texts show variable broad ligament development between species, most being consistent with the size and shape of the uterus and uterine tubes. The broad ligament in adult female rats is a simple peritoneal fold and is homologous with the mesentery of the testis and vas deferens in males. Patients with PMDS and bovine freemartins have a broad ligament with intermediate anatomy. In PMDS the broad ligament is elongated and narrow, and not attached to the pelvic wall. The broad ligament is the mesentery of the genital ducts, and its anatomy varies with the degree of Müllerian duct fusion. The absence of a human male homologue is unusual, as the genital mesentery persists in male rodents. Apparent lack of a male homologue in the human may relate to obliteration of the processus vaginalis. The variable development of the broad ligament in pathological conditions is consistent with a role for steroid hormones in its development. Copyright 2004 Wiley-Liss, Inc.
Photoneutron radiation field of ducts in barrier of 15 MV medical electron accelerators
NASA Astrophysics Data System (ADS)
Deng, Lei; Zhou, Ning; Chen, Yi-shui; Tu, Yu
2017-11-01
Shielding body of the high-energy medical electron accelerators is always penetrated by ducts, which would influence the shielding capability of local barrier. In order to quantitatively analyze the duct's impact on shielding of the photoneutron from 15 MV accelerators, the ambient dose equivalent rate and energy spectrum at the center of a typical duct and the external mouth of duct were calculated based on MCNP program for the first time. The results demonstrate that leakage neutrons at the external mouth of duct are mainly thermal neutron, and its dose rate is decreased with the increase of the intersection angle between duct and wall as well as the reduction of duct diameter. When a duct in a diameter no more than 30 cm penetrates the wall unidirectionally and the inclined Angle (θ) is 60°, neutron dose rate at the external mouth of duct could meet the requirements of protection. At last, according to the calculation results, some suggestions are proposed for the shielding design of ducts in walls.
Anomalous pancreatico-biliary ductal union with cystic dilatation of the bile duct.
Richer, J P; Faure, J P; Morichau-Beauchant, M; Dugue, T; Maillot, N; Kamina, P; Carretier, M
1998-01-01
We report, in an adult, an asymptomatic association between cystic dilation of the bile duct (type IV A in Todani's classification) and anomalous pancreatico-biliary ductal union (APBD) with stones in a long common channel. In APBD, the connection between the common bile duct and the main pancreatic duct is located outside the duodenal wall andis therefore not under the influence of the sphincter of Boyden. An abnormally long common channel is in excess of 15 mm. Two types of convergence anomalies are defined according to whether the bile duct opens into the main pancreatic duct (BP) or the main pancreatic duct into the bile duct (PB). In APBD, there is probably a reverse pressure gradient between the bile and pancreatic ducts, with regurgitation of pancreatic juice into the bile duct, repeated attacks of cholangitis, stenosis and cystic dilatation. A long common channel is associated with a higher incidence of carcinoma of the gall bladder of the bile duct.
Cooling Panel Optimization for the Active Cooling System of a Hypersonic Aircraft
NASA Technical Reports Server (NTRS)
Youn, B.; Mills, A. F.
1995-01-01
Optimization of cooling panels for an active cooling system of a hypersonic aircraft is explored. The flow passages are of rectangular cross section with one wall heated. An analytical fin-type model for incompressible flow in smooth-wall rectangular ducts with coupled wall conduction is proposed. Based on this model, the a flow rate of coolant to each design minimum mass flow rate or coolant for a single cooling panel is obtained by satisfying hydrodynamic, thermal, and Mach number constraints. Also, the sensitivity of the optimal mass flow rate of coolant to each design variable is investigated. In addition, numerical solutions for constant property flow in rectangular ducts, with one side rib-roughened and coupled wall conduction, are obtained using a k-epsilon and wall function turbulence model, these results are compared with predictions of the analytical model.
Lightweight Valve Closes Duct Quickly
NASA Technical Reports Server (NTRS)
Fournier, Walter L.; Burgy, N. Frank
1991-01-01
Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.
Granulomatous lobular mastitis.
Miliauskas, J R; Pieterse, A S; Williams, R S
1995-02-01
Two cases of benign lobular granulomatous mastitis, both clinically felt to be carcinoma, are reported. One patient was cured by local excision of the mass while the other was cured by oral prednisolone, demonstrating the variable ways to treat this entity. The clinical and histological features were similar to those noted in previous reports. Immunological studies revealed predominantly stromal T lymphocytes and only duct intra-epithelial T lymphocytes.
NASA Technical Reports Server (NTRS)
Fryer, B. A. (Compiler)
1980-01-01
Reference lists of approximately 900 published Langley Research Center reports in various areas of acoustics and noise control for the period 1940-1979 are presented. Specific topic areas covered include: duct acoustics; propagation and operations; rotating blade noise; jet noise; sonic boom; flow surface interaction noise; structural response/interior noise; human response; and noise prediction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, C.; Cummings, J.; Nigusse, B.
A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied bymore » adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.« less
Apparatus for supplying conditioned air at a substantially constant temperature and humidity
NASA Technical Reports Server (NTRS)
Obler, H. D. (Inventor)
1980-01-01
The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.
NASA Astrophysics Data System (ADS)
Yadav, Rupesh J.; Kore, Sandeep S.; Joshi, Prathamesh S.
2018-05-01
The experimental and numerical Nusselt number and friction factor investigation for turbulent flow through a non-circular duct with twisted-tape inserts have been presented. The non-circular ducts include square, hexagonal duct. The results of non-circular ducts are compared with circular duct. All the ducts have same equivalent diameter. The twist ratios used for the experiment are Y = 3.5, 4.5, 5.5 and 6.5. Experiments were carried out on square duct, hexagonal duct and circular duct. The Reynolds number lied between 10,000 and 1, 05,000. The present study is restricted to the flow of air at Pr = 0.7 only and within a narrow temperature range of 40 to 75 ΟC, within which the compressible nature of air can be neglected. The results reveal that, both Nusselt number and friction factor increases as the side of non-circular duct increases. Maximum Nusselt number and friction factor is obtained in case of circular duct with twisted tape. Further the correlations of Nu and f are given for different non circular duct with twisted tape insert for engineering applications for the turbulent regime. Since the thermal performance factor (η) is observed to be within the range of 0.8 to 1.13 for both circular and noncircular ducts, the overall benefit of using twisted tape in the flow field shall nevertheless be marginal.
2. VIEW NORTHWEST FROM LEFT TO RIGHT: COLD CALIBRATION BLOCKHOUSE, ...
2. VIEW NORTHWEST FROM LEFT TO RIGHT: COLD CALIBRATION BLOCKHOUSE, COLD CALIBRATION TEST STAND FOR FL ENGINE FOR SATURN V. EXHAUST DUCT IN FOREGROUND. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL
EFFICACY OF UV IRRADIATION ON EIGHT SPECIES OF BACILLUS
Ultraviolet irradiation has been used in the indoor environment to eliminate or control infectious diseases. Heating, ventilating and air-conditioning (HVAC) system components such as duct liners, cooling coils, drip pans, interior insulation and areas subjected to high levels of...
... Patients & Visitors Health Library Institutes & Departments Home / Health Library / Diagnostics & Testing / Bile Duct Exploration Advertising Policy Bile Duct Exploration Common bile duct exploration is ...
Mixing of Multiple Jets With a Confined Subsonic Crossflow
NASA Technical Reports Server (NTRS)
Holdeman, James D.
1998-01-01
Results from a recently completed enhanced mixing program are summarized in the two technical papers. These studies were parts of a High Speed Research (HSR)-supported joint Government/industry/university program that involved, in addition to the NASA Lewis Research Center, researchers at United Technologies Research Center, Allison Engine Company, CFD Research Corporation, and the University of California, Irvine. The studies investigated the mixing of jets injected normal to a confined subsonic mainsteam in both rectangular and cylindrical ducts. Experimental and computational studies were performed in both nonreacting and reacting flows. The orifice geometries and flow conditions were selected as typical of the complex three-dimensional flows in the combustion chambers in low-emission gas turbine engines. The principal conclusion from both the experiments and modeling was that the momentum-flux ratio J and orifice spacing S/H were the most significant flow and geometry variables, respectively. Conserved scalar distributions were similar-independent of reaction, orifice diameter H/d, and shape-when the orifice spacing and the square root of the momentum-flux ratio were inversely proportional. Jet penetration was critical, and penetration decreased as either momentum-flux ratio or orifice spacing decreased. We found that planar averages must be considered in context with the distributions. The mass-flow ratios and the orifices investigated were often very large. The jet-to-mainstream mass-flow ratio was varied from significantly less than 1 to greater than 1. The orifice-area to mainstream-cross-sectional-area was varied from approx. 0 to 0.5, and the axial planes of interest were often just downstream of the orifice trailing edge. Three-dimensional flow was a key part of efficient mixing and was observed for all configurations. As an example of the results, the accompanying figure shows the effects of different rates of mass addition on the opposite walls of a rectangular duct.
CT differentiation of mucin-producing cystic neoplasms of the liver from solitary bile duct cysts.
Kim, Hyoung Jung; Yu, Eun Sil; Byun, Jae Ho; Hong, Seung-Mo; Kim, Kyoung Won; Lee, Jong Seok; Kim, So Yeon
2014-01-01
The purpose of this study was to identify the CT features required for differentiating mucin-producing cystic neoplasms of the liver (mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct) from solitary bile duct cysts. CT images of pathologically confirmed mucinous cystic neoplasms (n = 15), cyst-forming intraductal papillary neoplasms of the bile duct (n = 16), and solitary bile duct cysts (n = 31) were reviewed. Analysis of the CT findings included shape, presence of septa, location of septa (peripheral vs central), thickness of septa (thin vs thick), mosaic pattern, mural nodules, intracystic debris, calcification, upstream bile duct dilatation, downstream bile duct dilatation, and communication between a cystic lesion and the bile duct. The maximum size of a cystic lesion and the maximum size of the largest mural nodule were measured. The presence of septa, central septa, mural nodules, upstream bile duct dilatation, and downstream bile duct dilatation were found to be significant CT findings for differentiating mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct from solitary bile duct cysts (p < 0.05 for each finding). When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucin-producing cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively. When two of these five criteria were used in combination, the sensitivity and specificity for diagnosing mucinous cystic neoplasms and cyst-forming intraductal papillary neoplasms of the bile duct were 87% (27 of 31) and 87% (27 of 31), respectively [corrected]. With the use of specific CT criteria, mucin-producing cystic neoplasms of the liver can be differentiated from solitary bile duct cysts with a high degree of accuracy.
Method and apparatus for duct sealing using a clog-resistant insertable injector
Wang, Duo; Modera, Mark P.
2010-12-14
A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.
NASA Technical Reports Server (NTRS)
Srivastava, R.; Reddy, T. S. R.
1997-01-01
The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carr, D.H.; Hadjis, N.S.; Banks, L.M.
Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highlymore » suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.« less
Combustor assembly in a gas turbine engine
Wiebe, David J; Fox, Timothy A
2015-04-28
A combustor assembly in a gas turbine engine includes a combustor device, a fuel injection system, a transition duct, and an intermediate duct. The combustor device includes a flow sleeve for receiving pressurized air and a liner surrounded by the flow sleeve. The fuel injection system provides fuel to be mixed with the pressurized air and ignited in the liner to create combustion products. The intermediate duct is disposed between the liner and the transition duct so as to define a path for the combustion products to flow from the liner to the transition duct. The intermediate duct is associated with the liner such that movement may occur therebetween, and the intermediate duct is associated with the transition duct such that movement may occur therebetween. The flow sleeve includes structure that defines an axial stop for limiting axial movement of the intermediate duct.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-04-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.
Flow regimes of adiabatic gas-liquid two-phase under rolling conditions
NASA Astrophysics Data System (ADS)
Yan, Chaoxing; Yan, Changqi; Sun, Licheng; Xing, Dianchuan; Wang, Yang; Tian, Daogui
2013-07-01
Characteristics of adiabatic air/water two-phase flow regimes under vertical and rolling motion conditions were investigated experimentally. Test sections are two rectangular ducts with the gaps of 1.41 and 10 mm, respectively, and a circular tube with 25 mm diameter. Flow regimes were recorded by a high speed CCD-camera and were identified by examining the video images. The experimental results indicate that the characteristics of flow patterns in 10 mm wide rectangular duct under vertical condition are very similar to those in circular tube, but different from the 1.41 mm wide rectangular duct. Channel size has a significant influence on flow pattern transition, boundary of which in rectangular channels tends asymptotically towards that in the circular tube with increasing the width of narrow side. Flow patterns in rolling channels are similar to each other, nevertheless, the effect of rolling motion on flow pattern transition are significantly various. Due to the remarkable influences of the friction shear stress and surface tension in the narrow gap duct, detailed flow pattern maps of which under vertical and rolling conditions are indistinguishable. While for the circular tube with 25 mm diameter, the transition from bubbly to slug flow occurs at a higher superficial liquid velocity and the churn flow covers more area on the flow regime map as the rolling period decreases.
[Imaging of the intrahepatic biliary tree with thick slice MR cholangiography].
Leclerc, J C; Cannard, L; Lefèvre, F; Debelle, L; Béot, S; Boccaccini, H; Bazin, C; Régent, D
2001-02-01
To assess the value of single shot fast spin echo MR sequence (SS-FSE) in the evaluation of the normal and pathologic intrahepatic biliary tree. 418 consecutive patients (457 examinations) referred for clinical and/or biological suspicion of biliary obstruction underwent MR cholangiopancreatography (MRCP). All patients were imaged with a Signa 1.5 T GE MR unit, with High Gradient Field Strength and Torso Phased Array Coil. Biliary ducts were imaged with SS-FSE sequence, coronal and oblique coronal 20 mm thick slices on a 256 x 256 matrix. Total acquisition time was 1 second. Source images were reviewed by two radiologists blinded to clinical information. In case of disagreement, a third radiologist's opinion was requested. In all cases, MRCP results were compared with direct biliary tract evaluation, other imaging studies and clinical and biological follow-up. In all cases, MRCP produced high quality images. Numerous branch of division were observed although the peripheral intrahepatic ducts were well seen in more than 90% in an area 2 cm below the capsule. The number of division was statistically higher when mechanical obstruction was present. Intrahepatic calculi or peripheral cholangiocarcinoma were well detect by MRCP. For the detection of cholangitis, MRCP sensitivity was 87.5% but the positive predictive value was only 57.7% because of a high number of false positive. The diagnosis of primary sclerosing cholangitis must be made only on strict criteria and slightly dilated peripheral bile ducts unconnected to the central ducts in several hepatic segments were a characteristic MR sign of primary sclerosing cholangitis. MRCP can be proposed as a first intention imaging technique for the evaluation of intrahepatic ducts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-02-01
A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences, 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs, and 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less
Compact Buried Ducts in a Hot-Humid Climate House
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallay, Dave
2016-01-07
"9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely onmore » encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.« less
In vivo reflectance confocal microscopy evaluation of cheilitis glandularis: a report of 5 cases.
Lourenço, Silvia V; Kos, Eliana; Borguezan Nunes, Thais; Bologna, Sheyla B; Sangueza, Martin; Nico, Marcello M S
2015-03-01
Cheilitis glandularis (CG) is an uncommon condition of unknown origin; it is clinically characterized by variable degrees of macrocheilia associated with red dilated ostia of minor salivary glands on the vermilion area, which secrete viscous saliva. Histopathological characteristics of CG are comprised of chronic sialadenitis with engorged acinar lobules and dilated ducts; CG also features chronic sun damage (actinic cheilitis and squamous cell carcinoma). These changes may be localized, and a punch biopsy specimen might fail to reveal enough criteria to support the diagnosis of CG. Reflectance confocal microscopy (RCM) is a noninvasive imaging technique that enables an in vivo en face visualization of tissues with a resolution close to conventional histopathology. Its use allows analysis of the entire lip, without excision. We reported the evaluation of 5 cases of CG based on clinical RCM and histopathological correlation. RCM examination of the lip vermilion mainly revealed a bright aspect of the superficial epithelial layers, which corresponded to labial keratosis. Alteration of the classical epithelial honeycomb pattern was observed in RCM, which corresponded to epithelial changes in actinic cheilitis at histopathology. Round, dark empty spaces intermingling the epithelium, corresponded to the ectopic excretory salivary gland ducts that open their ostia within the lip vermilion. In the lamina propria, the most striking feature was superficial salivary gland lobules, seen as dark gray lobular structures. Our study, demonstrated the use of RCM in the evaluation of CG, showing that a correlation between the clinical, digital RCM images and histopathology improved the diagnostic skills in CG evaluation.
Bile Duct Cancer (Cholangiocarcinoma) Treatment (PDQ®)—Health Professional Version
Bile duct cancer (also called cholangiocarcinoma) can occur in the bile ducts in the liver (intrahepatic) or outside the liver (perihilar or distal extrahepatic). Learn about the types of bile duct cancer, risk factors, clinical features, staging, and treatment for bile duct cancer in this expert-reviewed summary.
Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth
2012-01-01
Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248
Ducted turbine theory with right angled ducts
NASA Astrophysics Data System (ADS)
McLaren-Gow, S.; Jamieson, P.; Graham, J. M. R.
2014-06-01
This paper describes the use of an inviscid approach to model a ducted turbine - also known as a diffuser augmented turbine - and a comparison of results with a particular one-dimensional theory. The aim of the investigation was to gain a better understanding of the relationship between a real duct and the ideal diffuser, which is a concept that is developed in the theory. A range of right angled ducts, which have a rim for a 90° exit angle, were modelled. As a result, the performance of right angled ducts has been characterised in inviscid flow. It was concluded that right angled ducts cannot match the performance of their associated ideal diffuser and that the optimum rotor loading for these turbines varies with the duct dimensions.
Air conditioning system and component therefore distributing air flow from opposite directions
NASA Technical Reports Server (NTRS)
Obler, H. D.; Bauer, H. B. (Inventor)
1974-01-01
The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.
Nagano, Yasuhiko; Matsuo, Kenichi; Gorai, Katsuya; Sugimori, Kazuya; Kunisaki, Chikara; Ike, Hideyuki; Tanaka, Katsuaki; Imada, Toshio; Shimada, Hiroshi
2006-01-01
We present a case of a 72-year-old man with a common bile duct cancer, who was initially believed to have multiple liver metastases based on computed tomography findings, and in whom magnetic resonance cholangiography (MRC) revealed a diagnosis of bile duct hamartomas. At exploration for pancreaticoduodenectomy, liver palpation revealed disseminated nodules at the surface of the liver. These nodules showed gray-white nodular lesions of about 0.5 cm in diameter scattered on the surface of both liver lobes, which were looked like multiple liver metastases from bile duct cancer. Frozen section of the liver biopsy disclosed multiple bile ducts with slightly dilated lumens embedded in the collagenous stroma characteristics of multiple bile duct hamartomas (BDHs). Only two reports have described the MRC features of bile duct hamartomas. Of all imaging procedures, MRC provides the most relevant features for the imaging diagnosis of bile duct hamartomas. PMID:16534895
[Iatrogenic bile duct injuries during the process of laparoscopic cholecystectomy].
Qian, G; Wu, M; Zhang, Y
1995-11-01
Twelve patients with iatrogenic bile duct injuries occurred during laparoscopic cholecystectomy (LC) were treated from June 1992 to May 1994. All the patients underwent re-operation and were cured. The causes and characteristics of the injuries were: (1) perforation of the common hepatic or common bile duct caused by dissecting hook (3 cases); (2) necrosis and perforation of the common hepatic duct due to diathermic injury (1 case); (3) clamping of the common hepatic duct by Ti clip (1 case); (4) secondary high bile duct stricture following a failed end-to-end anastomosis or hepatico-cholangio-jejunostomy of the amputated common hepatic duct (5 cases); (5) delayed high bile duct stricture (2 cases). It is emphasized that the severity of bile duct injuries by LC be should not overlooked, and more experience in this field be accumulated to avoid this serious complication.
Jeyarajah, D Rohan; Khithani, Amit; Curtis, David; Galanopoulos, Christos A
2010-01-01
Pancreaticoduodenectomy (PD) is the standard of care in the treatment of premalignant and malignant diseases of the head of the pancreas. Variability exists in anastomosis with the pancreatic remnant. This work describes a safe and easy modification for the pancreatic anastomosis after PD. Ten patients underwent the "Whip-Stow" procedure for the management of the pancreatic remnant. PD combined with a Puestow (lateral pancreaticojejunostomy [LPJ]) was completed using a running single-layer, 4-0 Prolene obeying a duct-to-mucosa technique. LPJ and pancreaticogastrostomy (PG) historical leak rates are reported to be 13.9 and 15.8 per cent, respectively. Mortality, leak, and postoperative bleeding rates were 0 per cent in all patients. The Whip-Stow was completed without loops or microscope with a 4-0 single-layer suture decreasing the time and complexity of the anastomosis. Average time was 12 minutes as compared with the 50 minutes of a 5 or 6-0 interrupted, multilayered duct-mucosa anastomosis. Benefits included a long-segment LPJ. In this study, the Whip-Stow procedure has proven to be a safe and simple approach to pancreatic anastomosis in selected patients. This new technique provides the benefit of technical ease while obeying the age old principles of obtaining a wide duct to mucosa anastomosis.
Miyake, K; Arima, H; Irie, T; Hirayama, F; Uekama, K
1999-01-01
The enhancing effects of dimethyl-beta-cyclodextrin (DM-beta-CyD) on the absorption of cyclosporin A (CsA) after oral administration to rats under bile duct-cannulated and -noncannulated conditions were investigated. The dissolution rate of CsA was markedly augmented by complexation with DM-beta-CyD. In a closed loop in situ study, DM-beta-CyD considerably increased the cumulative amounts of CsA in the mesenteric venous blood after injection of the aqueous CsA suspension into the small intestinal sac of rats. In addition, the cumulative amount ratio of M1, the dominant metabolite of CsA in rats, to CsA in the mesenteric venous blood for up to 40 min after the injection of the CsA-DM-beta-CyD suspension into the sac was lower than that of the CsA suspension alone. DM-beta-CyD inhibited the bioconversion of CsA in the small intestinal microsomes of rats. These results indicate that the bioconversion of CsA was abated by complexation with DM-beta-CyD. An in vivo study revealed that DM-beta-CyD increased the transfer of CsA to blood, not lymph, with low variability in the absorption after oral administration of the CsA suspension to rats. The variability of bioavailability of DM-beta-CyD complex was lower than that of Sandimmune, although the extent of bioavailability of DM-beta-CyD was only a little higher than that of Sandimmune. The bioavailability of CsA or its DM-beta-CyD complex was appreciably decreased by the cannulation of the bile duct of rats, and the extent of the lowering in the bioavailability in the presence of DM-beta-CyD was much less serious than that of CsA alone. The present results suggest that DM-beta-CyD is particularly useful in designing oral preparations of CsA with an enhanced bioavailability and a reduced variability in absorption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gagnon, J.A.; Schaefer, D.D.; Shaw, D.N.
1980-09-02
A compact, helical screw compressor/expander unit is described that is mounted in a vehicle and connected to the vehicle engine driven drive shaft has inlet and outlet ports and a capacity control slide valve and a pressure matching or volume ratio slide valve, respectively, for said ports. A refrigerant loop includes the compressor, a condenser mounted in the path of air flow over the engine and an evaporator mounted in a fresh air/cab return air flow duct for the occupant. Heat pipes thermally connect the cab air flow duct to the engine exhaust system which also bears the vapor boiler.more » Selectively operated damper valves control the fresh air/cab return air for passage selectively over the evaporator coil and the heat pipes as well as the exhaust gas flow over opposite ends of the heat pipes and the vapor boiler.« less
Lin, Man-Xia; Ye, Jie-Yi; Tian, Wen-Shuo; Xu, Ming; Zhuang, Bo-Wen; Lu, Ming-De; Xie, Xiao-Yan; Kuang, Ming
2017-04-01
Bile duct injury after ablation of malignant liver tumors (MLTs) was not unusual and should be avoided. However, few studies have focused on evaluating the risk factors for intrahepatic bile duct injury. To evaluate the risk factors for intrahepatic bile duct injury after ablation of MLTs and to evaluate the minimum safe distance for ablating tumors abutting bile ducts. Sixty-five patients with intrahepatic bile duct injury after ablation of MLTs, and 65 controls were recruited. Risk factors for intrahepatic bile duct injury were analyzed. Tumor location was recorded as ≤5 mm (group A), 5-10 mm (group B), and >10 mm (group C) from the right/left main duct or segmental bile duct. Ascites history (P < 0.001), TACE treatment history (P = 0.025), intrahepatic bile duct dilatation before ablation (P < 0.001), and tumor location (P = 0.000) were identified as significant risk factors for intrahepatic bile duct injury. Significant differences in the risk of intrahepatic bile duct injury were found between groups B and C (P = 0.000), but not between groups A and B (P = 0.751). Ascites history (P = 0.002) and tumor location (P < 0.001) were independent predictors with the OR (95 % confidence interval) of 39.31(3.95-391.69) and 16.56 (5.87-46.71), respectively. Bile duct injury after ablation of MLTs was the result of local treatment-related factors combined with the patients' general condition. The minimum safe distance for ablation of tumor abutting a bile duct was 10 mm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jae Woong, E-mail: cooljay@korea.ac.kr; Lu, David S. K., E-mail: dlu@mednet.ucla.edu; Osuagwu, Ferdnand, E-mail: fosuagwu@mednet.ucla.edu
2013-11-07
PurposeTo evaluate the chronological effects of irreversible electroporation (IRE) on large hilar bile ducts in an in vivo porcine model correlated with computed tomography (CT) cholangiography and histopathology.Materials and MethodsTwelve IRE zones were made along hilar bile ducts intraoperatively under ultrasound (US)-guidance in 11 pigs. Paired electrodes were placed either on opposing sides of the bile duct (straddle [STR]) or both on one side of the bile duct (one-sided [OSD]). The shortest electrode-to-duct distance was classified as periductal (≤2 mm) or nonperiductal (>2 mm). CT cholangiography and laboratory tests were performed before IRE and again at 2 days, 4 weeks, and 8 weeks after IRE.more » Degree of bile duct injury were graded as follows: grade 0 = no narrowing; grade 1 = ≤50 % duct narrowing; grade 2 = >50 % narrowing without proximal duct dilatation; grade 3 = grade 2 with proximal duct dilatation; and grade 4 = grade 3 with enzyme elevation. Pigs were selected for killing and histopathology at 2 days, 4, and 8 weeks.ResultsNonperiductal electrode placement produced no long-term strictures in 5 of 5 ducts. Periductal electrode placement produced mild narrowing in 6 of 7 ducts: 5 grade 1 and 1 grade 2. None showed increased enzymes. There was no significant difference between STR versus OSD electrode placement. Histopathology showed minor but relatively greater ductal mural changes in narrowed ducts.ConclusionIn the larger hilar ducts, long-term patency and mural integrity appear resistant to IRE damage with the energy deposition used, especially if the electrode is not immediately periductal in position.« less
Yaprak, Onur; Dayangac, Murat; Akyildiz, Murat; Demirbas, Tolga; Guler, Necdet; Bulutcu, Fisun; Bassullu, Nuray; Akun, Elif; Yuzer, Yildiray; Tokat, Yaman
2012-01-01
Background Biliary complications that developed after right lobe liver transplantation from living donors were studied in a single centre. Methods From 2004 to 2010, 200 consecutive living donor right lobe liver transplantations were performed. The database was evaluated retrospectively. Biliary complications were diagnosed according to clinical, biochemical and radiological tests. The number of biliary ducts in the transplanted graft, the surgical techniques used for anastomosis, biliary strictures and bile leakage rates were analysed. Results Of a total of 200 grafts, 117 invloved a single bile duct, 77 had two bile ducts and in six grafts there were three bile ducts. In 166 transplants, the anastomosis was performed as a single duct to duct, in 21 transplants double duct to ducts, in one transplant, three duct to ducts and in 12 transplants as a Roux-en-Y reconstruction. In all, 40 bile leakages (20%) and 17 biliary strictures (8.5%) were observed in 49 patients resulting in a total of 57 biliary complications (28.5%). Seventeen patients were re-operated (12 as a result of bile leakages and five owing to biliary strictures). Conclusion Identification of more than one biliary orifice in the graft resulted in an increase in the complication rates. In grafts containing multiple orifices, performing multiple duct-to-duct (DD) or Roux-en-Y anastomoses led to a lower number of complications. PMID:22151451
Bosland, M C; Ford, H; Horton, L
1995-06-01
This study determined the incidence of prostate adenocarcinoma following long-term treatment of NBL and Sprague-Dawley rats with estradiol-17 beta or diethylstilbestrol (DES) plus testosterone and it defined the origin of these tumors. NBL and Sprague-Dawley rats were treated with two Silastic tubing implants (i.d. 1.6 mm, o.d. 3.2 mm) containing a 2 cm long filling of testosterone and one implant containing a 1 cm long filling of estradiol-17 beta or DES. Control animals received empty implants. Treated animals were killed when moribund and controls were killed at 91 (NBL) or 75 (Sprague-Dawley) weeks after initiation of treatment and accessory sex glands were sampled for histopathological examination of multiple step sections. Prostatic adenocarcinoma occurred in 100% of NBL rats after treatment with estradiol-17 beta or DES plus testosterone for 44 and 59 weeks (group means) respectively. Adenocarcinoma incidences were lower in Sprague-Dawley rats. The adenocarcinomas were small, microscopic, invasive tumors and they were spatially closely associated with the periurethral ducts of the dorsal, lateral and/or anterior (= coagulating gland) prostate, but never with the ducts of the ventral lobe and seminal vesicles. One adenocarcinoma was of uncertain origin. Duct-acinar dysplastic lesions occurred in the periphery of the dorsal and lateral prostate of all hormone-treated NBL and many Sprague-Dawley rats, but did not appear to give rise to carcinoma. Although some adenocarcinomas were contiguous with dysplastic ducts of the peripheral dorsolateral prostate, the main mass of these neoplasms was located in the periurethral area. Also, most adenocarcinomas were only connected with the periurethral ducts, in which atypical hyperplasia occurred following hormone treatment for 36 weeks or longer. Thus atypical hyperplasia of the periurethral prostate ducts, but not peripheral duct-acinar dysplasia, appeared to be the likely precursor of the induced carcinomas. Testosterone plus DES, but not estradiol-17 beta, induced marked dysplasia-like lesions in the acini of the ventral prostate of all NBL and many Sprague-Dawley rats. These lesions had progressed to carcinoma in situ (or adenoma) in 46% of NBL rats.
Kim, Hyun-Jung; Yoo, Young Sam; Park, Kyeongmee; Kwon, Ji-Eun; Kim, Jung Yeon; Monzon, Federico A
2011-09-01
Carcinoma arising from Warthin tumor is extremely rare. A 79-year-old man was admitted for a firm, well-defined, 5-cm left infra-auricular mass. Aspiration cytology showed many lymphohistiocytes and oncocytes in a proteinaceous background, compatible with Warthin tumor. A left superficial parotidectomy showed a solid mass around the cyst wall. The tumor cells of the solid area were arranged as infiltrative ducts with a few foci of malignant transformation. Virtual karyotyping disclosed a complex pattern of genetic aberrations with a focal amplification in 12q14-q21.2. This chromosomal region contains the MDM2 (murine double minute) gene, which regulates p53 inactivation. HER2 fluorescence in situ hybridization showed a focal amplification. Subsequently, the patient underwent total parotidectomy and ipsilateral neck dissection for a recurrence. To our knowledge, this is the first case of salivary duct carcinoma arising from Warthin tumor. The essential molecular pathway has not been reported, we presume an important role of MDM2 amplification- P53 inactivation.
Pathological Studies of “Sudden Death Syndrome” in Broiler Chickens
Ononiwu, J.C.; Thomson, R.G.; Carlson, H.C.; Julian, R.J.
1979-01-01
Sudden death syndrome usually occurs in heavy, fast-growing and healthy-looking broilers. Most of the affected birds are males. The characteristic necropsy changes are seen in well-fleshed broilers with edema and generalized pulmonary congestion, recently ingested feed in the crop and gizzard, distended intestine with creamy content and empty gall bladder. The liver and kidneys are slightly enlarged and the latter have patchy areas of subcapsular hemorrhage. The heart contains clotted blood in the atria but the ventricles are often empty and the left ventricle in particular assumes a hypertrophied appearance. Microscopic examination of heart muscle reveals degeneration of fibers, separation of cardiac muscle fibers by edema and infiltration of heterophils. The lungs have severe vascular congestion, inflammatory cell infiltration in the mucosa of the secondary bronchi and edema fluid in the tertiary bronchi and interlobular connective tissue. The liver has moderate bile duct hyperplasia, periportal hepatitis and mononuclear cell infiltration adjacent to bile ducts which possibly leads to bile duct constriction. The kidneys have subcapsular and parenchymatous hemorrhage. ImagesFIGURE 1.FIGURE 2. PMID:436100
DOE Office of Scientific and Technical Information (OSTI.GOV)
Othman, M. N. K., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Zuradzman, M. Razlan, E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my; Hazry, D., E-mail: najibkhir86@gmail.com, E-mail: zuradzman@unimap.edu.my, E-mail: hazry@unimap.edu.my, E-mail: khairunizam@unimap.edu.my, E-mail: shahriman@unimap.edu.my, E-mail: s.yaacob@unimap.edu.my, E-mail: syedfaiz@unimap.edu.my, E-mail: abadal@unimap.edu.my
2014-12-04
This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors andmore » the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.« less
An experimental study of planar heterogeneous supersonic confined jets
NASA Astrophysics Data System (ADS)
Tanis, Frederick J., Jr.
1994-12-01
The effects of varying the exit pressure of a supersonic helium jet exhausting coaxially with two parallel supersonic air streams into a constant area duct were investigated. The method used to evaluate the mass entrainment rate was to measure helium molar concentration profiles and mass flux across the duct using a binary gas probe then calculate the mass entrainment into the helium jet. In order to conduct this study a novel binary gas probe was developed which allowed helium concentration and mass flux data to be obtained during continuous traverses across the supersonic flowfield. High exit pressure ratio (EPR) led to improved overall mixing compared to the baseline case with an EPR near unity. The high EPR caused low mass entrainment along the jet shear layers due to high convective Mach numbers and velocity ratios, but the high EPR caused oblique shocks to form which reflected off the duct walls and intersected with the helium jet several times causing significant mass entrainment due to numerous shock-shear layer interactions (SSLI's). A correlation between the vorticity generated during a SSLI and the mass entrainment into the jet was developed.
Modeling Vortex Generators in a Navier-Stokes Code
NASA Technical Reports Server (NTRS)
Dudek, Julianne C.
2011-01-01
A source-term model that simulates the effects of vortex generators was implemented into the Wind-US Navier-Stokes code. The source term added to the Navier-Stokes equations simulates the lift force that would result from a vane-type vortex generator in the flowfield. The implementation is user-friendly, requiring the user to specify only three quantities for each desired vortex generator: the range of grid points over which the force is to be applied and the planform area and angle of incidence of the physical vane. The model behavior was evaluated for subsonic flow in a rectangular duct with a single vane vortex generator, subsonic flow in an S-duct with 22 corotating vortex generators, and supersonic flow in a rectangular duct with a counter-rotating vortex-generator pair. The model was also used to successfully simulate microramps in supersonic flow by treating each microramp as a pair of vanes with opposite angles of incidence. The validation results indicate that the source-term vortex-generator model provides a useful tool for screening vortex-generator configurations and gives comparable results to solutions computed using gridded vanes.
Low Velocity Difference Thermal Shear Layer Mixing Rate Measurements
NASA Technical Reports Server (NTRS)
Bush, Robert H.; Culver, Harry C. M.; Weissbein, Dave; Georgiadis, Nicholas J.
2013-01-01
Current CFD modeling techniques are known to do a poor job of predicting the mixing rate and persistence of slot film flow in co-annular flowing ducts with relatively small velocity differences but large thermal gradients. A co-annular test was devised to empirically determine the mixing rate of slot film flow in a constant area circular duct (D approx. 1ft, L approx. 10ft). The axial rate of wall heat-up is a sensitive measure of the mixing rate of the two flows. The inflow conditions were varied to simulate a variety of conditions characteristic of moderate by-pass ratio engines. A series of air temperature measurements near the duct wall provided a straightforward means to measure the axial temperature distribution and thus infer the mixing rate. This data provides a characterization of the slot film mixing rates encountered in typical jet engine environments. The experimental geometry and entrance conditions, along with the sensitivity of the results as the entrance conditions vary, make this a good test for turbulence models in a regime important to modern air-breathing propulsion research and development.
NASA Astrophysics Data System (ADS)
Othman, M. N. K.; Zuradzman, M. Razlan; Hazry, D.; Khairunizam, Wan; Shahriman, A. B.; Yaacob, S.; Ahmed, S. Faiz; Hussain, Abadalsalam T.
2014-12-01
This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.
[Bile duct cysts; an unusual cause of jaundice in paediatrics. Presentation of a case series].
López Ruiz, Rocío; Aguilera Alonso, David; Muñoz Aguilar, Gemma; Fonseca Martín, Rosa
2016-01-01
Cysts of the bile duct or choledochal cysts are rare diseases in our area. The aetiology is unknown, with the most accepted hypothesis being a pancreatobiliary maljunction anomaly. To analyse the clinical data, diagnosis and treatment of a number of patients with choledochal cyst, as well as presenting an update on this condition. A retrospective descriptive study was performed on paediatric patients diagnosed with choledochal cyst in the last 20 years in a tertiary hospital. A total of 4 choledochal cyst cases in childhood, predominantly female, are pre- sented. The most frequent reason for consultation was vomiting, and presenting with jaundice and choluria in all cases. Patients with choledochal cyst were classified as type I in 3 cases, and one case of type IVa. In all cases surgical treatment was performed; any patient had complications to date. Cysts of the bile ducts have a low prevalence. The treatment of choice is surgical, requiring close monitoring due to the risk of cholangiocarcinoma. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Hemorrhagic Cholecystitis in a Patient on Maintenance Dialysis
Shishida, Masayuki; Ikeda, Masahiro; Karakuchi, Nozomi; Ono, Kosuke; Tsukiyama, Naofumi; Shimomura, Manabu; Oishi, Koichi; Miyamoto, Kazuaki; Toyota, Kazuhiro; Sadamoto, Seiji; Takahashi, Tadateru
2017-01-01
The present paper describes a case of hemorrhagic cholecystitis in a patient on maintenance dialysis. The patient presented with right upper quadrant abdominal pain. Computed tomography revealed swelling of the gallbladder, high- and isodensity contents of the gallbladder, and high-density stone in the gallbladder neck. He was hospitalized for suspected acute cholecystitis. After hospitalization, his levels of total bilirubin, aspartate aminotransferase, and alanine aminotransferase increased. T2-weighted magnetic resonance imaging showed low-intensity contents expanded to include a wide area from the common bile duct to the cystic duct and gallbladder neck. Endoscopic retrograde cholangiopancreatography revealed clotting from the duodenal papilla. After cannulation of the bile duct, old blood and pus began to flow from the mammary papilla, and an endoscopic nasobiliary drainage tube was placed. After his liver function had improved, the patient underwent laparoscopic cholecystectomy. His sample revealed that the gallbladder was filled with blood clots and stones. His postoperative course was uneventful and he was discharged on day 19 after the procedure. Although hemorrhagic cholecystitis is rare, it should be considered as a differential diagnosis for patients on dialysis who have acute abdominal symptoms. PMID:29033767
Traumatic resin ducts as indicators of bark beetle outbreaks
R. Justin DeRose; Matthew F. Bekker; James N. Long
2017-01-01
The formation of traumatic resin ducts (TRDs) represents an important induced defense in woody plants that enhances oleoresin production and flow in response to environmental perturbations. In some genera (Pinus), resin ducts are copious and conspicuous; however, in others (Picea), resin ducts are relatively rare. The occurrence and strength of resin ducts, in...
2018-05-22
Adult Primary Cholangiocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Metastatic Extrahepatic Bile Duct Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Unresectable Extrahepatic Bile Duct Cancer
Numerical and experimental investigation of conventional and un-conventional preswirl duct for VLCC
NASA Astrophysics Data System (ADS)
Shin, Hyun-Joon; Lee, Jong-Seung; Lee, Kang-Hoon; Han, Myung-Ryun; Hur, Eui-Beom; Shin, Sung-Chul
2013-09-01
This paper shows the study of preswirl duct as an effective energy saving devices that have been devised and reviewed to support the propeller performance, especially for the ship of VLCC with large block coefficients. From the bare hull wake measurements, typical upper/lower asymmetry of hull wake at the propeller disk was found. The 2 kinds of pre-swirl duct, Unconventional half circular duct and Conventional circular pre-swirl duct have been designed and reviewed to recover the loss of propeller running in that condition. The general function of the pre-swirl duct was set to work against this asymmetry of wake and generate pre-swirled flow into the propeller against the propeller rotating direction. The optimum self propulsion tests with various angle configurations were carried out and the best configuration was decided. Accordingly, cavitation test was carried out with best configuration of unconventional half circular duct. The blade surface and tip vortex cavitation behaved smoother when the duct was mounted. The hull pressure amplitudes reflected this difference, so the hull pressure amplitude with duct was smaller than that of without duct.
Nakamoto, Tetsuji; Shiba, Yoshiki; Hirono, Chikara; Sugita, Makoto; Takemoto, Kazuhisa; Iwasa, Yoshiko; Akagawa, Yasumasa
2002-09-01
Fluid secretion is observed at the openings of ducts in the exocrine gland. It remains unclear whether the ducts are involved in fluid secretion in the salivary glands. In the present study, we investigated the exclusion of fluorescent dye from the duct lumen by carbachol (CCh) in isolated parotid intralobular duct segments to clarify the ability of the ducts for the fluid secretion. When the membrane-impermeable fluorescent dye, sulforhodamine, was added to the superfused extracellular solution, quantitative fluorescence images of the duct lumen were obtained under the optical sectioning at the level of the duct lumen using a confocal laser scanning microscope. CCh decreased the fluorescent intensity in the duct lumen during the superfusion of the fluorescent dye, and CCh flushed out small viscous substances stained with the fluorescent dye from isolated duct lumen, suggesting that CCh might induce fluid secretion in the duct, leading to the clearance of the dye and small stained clumps from the duct lumen. CCh-induced clearance of the fluorescent dye was divided into two phases by the sensitivity to external Ca2+ and methazolamide, an inhibitor for carbonic anhydrase. The initial phase was insensitive to these, and the subsequent late phase was sensitive to these. A major portion in the late phase was inhibited by removal of bicarbonate in the superfusion solution and DPC, but not low concentration of external Cl-, bumetanide or DIDS, suggesting that methazolamide-sensitive production of HCO3-, but not the Cl- uptake mechanism, might contribute to the CCh-induced clearance of the dye from the duct lumen. These results represent the first measurements of fluid movement in isolated duct segments, and suggest that carbachol might evoke fluid secretion possibly through Ca2+-activated, DPC-sensitive anion channels with HCO3- secretion in the rat parotid intralobular ducts.
Carcinoids of the common bile duct: a case report and literature review
Ross, Alison C.; Hurley, James B.; Hay, W. Bruce; Rusnak, Conrad H.; Petrunia, Denis M.
1999-01-01
Carcinoids of the extrahepatic bile ducts and particularly the common bile duct are extremely rare. A 65-year-old woman presented with obstructive jaundice. Laboratory and imaging studies gave results that were consistent with an obstructing lesion in the common bile duct. In this case, a stent was inserted initially to decompress the bile ducts. Subsequently a laparotomy and pancreaticoduodenectomy were performed and a tissue diagnosis of carcinoid of the common bile duct was made. The patient was well with no evidence of recurrence 17 months postoperatively. The authors believe this is the 19th reported case of an extrahepatic bile duct carcinoid. PMID:10071590
Beach, Raymond J.; Honea, Eric C.; Bibeau, Camille; Mitchell, Scott; Lang, John; Maderas, Dennis; Speth, Joel; Payne, Stephen A.
2000-01-01
A hollow lensing duct to condense (intensify) light using a combination of focusing using a spherical or cylindrical lens followed by reflective waveguiding. The hollow duct tapers down from a wide input side to a narrow output side, with the input side consisting of a lens that may be coated with an antireflective coating for more efficient transmission into the duct. The inside surfaces of the hollow lens duct are appropriately coated to be reflective, preventing light from escaping by reflection as it travels along the duct (reflective waveguiding). The hollow duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials.
Convolution seal for transition duct in turbine system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston
2015-05-26
A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface feature for interfacing with an adjacent transition duct. The turbine system further includes a convolution seal contacting the interface feature to provide a seal between the interface feature andmore » the adjacent transition duct.« less
... tenderness or inflammation of the clogged duct (periductal mastitis). Mammary duct ectasia most often occurs in women ... that's turned inward (inverted) A bacterial infection called mastitis also may develop in the affected milk duct, ...
Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program
NASA Technical Reports Server (NTRS)
Beckemeyer, R. J.; Sawdy, D. T.
1971-01-01
An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.
Fan, Wenge; Zhang, Qingsong; Ye, Xun; Fan, Zhijiang
2018-01-01
To observe the morphological changes in paraurethral ducts infected with gonococci in men before and after the administration of the ceftriaxone therapy using high-frequency ultrasound and determine its clinical significance. Thirty-two male patients with gonococcal paraurethral duct infection were enrolled. Their lesions were examined using an ACUSON X300 ultrasound system before and after they were subjected to ceftriaxone therapy. The paraurethral duct was completely closed 3-4 days after ceftriaxone treatment in 30 patients. Paraurethral duct closure began from the blind end and proceeded gradually towards its orifice; during closure, the paraurethral duct diameter showed no apparent change. These 30 patients whose paraurethral ducts closed were considered cured. In the remaining 2 patients, the length and diameter of the paraurethral ducts showed no change before and after ceftriaxone treatment; one patient was unresponsive to ceftriaxone treatment, and the other had secondary dilatation of the paraurethral duct. These 2 patients were cured after surgery. High-frequency ultrasound enables dynamic observation of the morphological changes in paraurethral ducts infected with gonococci before and after ceftriaxone therapy. High-frequency ultrasound can provide valuable information for incision, drainage, and wedge resection of paraurethral ducts. © 2017 S. Karger AG, Basel.
NASA Technical Reports Server (NTRS)
Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.
1997-01-01
This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.
Variable-Depth Liner Evaluation Using Two NASA Flow Ducts
NASA Technical Reports Server (NTRS)
Jones, M. G.; Nark, D. M.; Watson, W. R.; Howerton, B. M.
2017-01-01
Four liners are investigated experimentally via tests in the NASA Langley Grazing Flow Impedance Tube. These include an axially-segmented liner and three liners that use reordering of the chambers. Chamber reordering is shown to have a strong effect on the axial sound pressure level profiles, but a limited effect on the overall attenuation. It is also shown that bent chambers can be used to reduce the liner depth with minimal effects on the attenuation. A numerical study is also conducted to explore the effects of a planar and three higher-order mode sources based on the NASA Langley Curved Duct Test Rig geometry. A four-segment liner is designed using the NASA Langley CDL code with a Python-based optimizer. Five additional liner designs, four with rearrangements of the first liner segments and one with a redistribution of the individual chambers, are evaluated for each of the four sources. The liner configuration affects the sound pressure level profile much more than the attenuation spectra for the planar and first two higher-order mode sources, but has a much larger effect on the SPL profiles and attenuation spectra for the last higher-order mode source. Overall, axially variable-depth liners offer the potential to provide improved fan noise reduction, regardless of whether the axially variable depths are achieved via a distributed array of chambers (depths vary from chamber to chamber) or a group of zones (groups of chambers for which the depth is constant).
Morais Pérez, D
2004-01-01
The duct of the parotid gland had been indiscriminately named Stenon's duct or Stensen's duct. In order to establish its origin we carried out a biographic search and a brief revision of the life of the great anatomist, geologist, palaeontologist, bishop and finally Saint Nicolaus Stensen.
NASA Astrophysics Data System (ADS)
Gish, Andrew
2015-11-01
Ducts (also called shrouds) have been shown to improve performance of hydrokinetic turbines in some situations, bringing the power coefficient (Cp) closer to the Betz limit. Here we investigate optimization of the duct design as well as the addition of stator blades upstream of the turbine rotor to introduce pre-swirl in the flow. A small scale three-bladed turbine was tested in a towing tank. Three cases (bare turbine, with duct, and with duct and stators) were tested over a range of flow speeds. Important parameters include duct cross-sectional shape, blade-duct gap, stator cross-sectional shape, and stator angle. For each test, Cp was evaluated as a function of tip speed ratio (TSR). Experimental results were compared with numerical simulations. Results indicate that ducts and stators can improve performance at slower flow speeds and lower the stall speed compared to a bare turbine, but may degrade performance at higher speeds. Ongoing efforts to optimize duct and stator configurations will be discussed.
Investigation of the tone-burst tube for duct lining attenuation measurement
NASA Technical Reports Server (NTRS)
Soffel, A. R.; Morrow, P. F.
1972-01-01
The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.
Zhang, Bo; Xu, Jin; Liu, Chen; Long, Jiang; Liu, Liang; Xu, Yongfeng; Wu, Chuntao; Luo, Guopei; Ni, Quanxing; Li, Min; Yu, Xianjun
2013-01-01
Pancreaticojejunostomy is the key procedure of pancreaticoduodenectomy. Our study introduced a new pancreaticojejunal (PJ) anastomosis named "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy. Nighty-two patients underwent pancreaticojejunostomy with either conventional duct-to-mucosa pancreaticojejunostomy or the new "papillary-like main pancreatic duct invaginated" techniques were analyzed retrospectively from January 2010 to September 2012. The incidence of pancreatic fistula was 15.7% (8/51) for the "papillary-like main pancreatic duct invaginated" group and 19.5% (8/41) for the duct-to-mucosa fashion respectively. It is noteworthy that the rate of grade B/C postoperative pancreatic fistula (POPF) in the "papillary-like main pancreatic duct invaginated" group was significantly lower than that of the duct-to-mucosa group (P = 0.039). There were no differences in the incidence of postoperative morbidity and mortality such as postoperative hemorrhage, delayed gastric emptying or remnant pancreatitis. The "papillary-like main pancreatic duct invaginated" pancreaticojejunostomy could provide a feasible option to pancreatic surgeons for patients with normal soft pancreas.
Prevention of bile duct injury: the case for incorporating educational theories of expertise.
McKinley, Sophia K; Brunt, L Michael; Schwaitzberg, Steven D
2014-12-01
Over 700,000 laparoscopic cholecystectomies are performed yearly in the US. Despite multiple advantages of laparoscopic surgery, the increased rate of bile duct injury (BDI) compared to the traditional, open approach to cholecystectomy remains problematic. Due to the seriousness of bile duct injury, the time has come for an aggressive educational campaign to better train laparoscopic surgeons in order to reduce the incidence of this life-threatening and expensive complication. We performed a literature review of what is currently known about the causes of bile duct injury during laparoscopic cholecystectomy. Based on these reviews, we identified educational theories of expertise that may be relevant in understanding variable rates of BDI between surgeons. Finally, we applied educational theories of expertise to the problem of BDI in laparoscopic cholecystectomy to propose how to develop and design an effective educational approach for the prevention of BDI. Multiple studies demonstrate that the primary causes of BDI during laparoscopic cholecystectomy are non-technical. Additionally, there exists a learning curve in which the rates of BDI are higher in a surgeon's earlier cases compared to later cases and that some surgeons perform laparoscopic cholecystectomy with significantly fewer injuries than others. Educational theories indicate that interventions that optimize novice to expert development require (1) revealing expert knowledge to novices and (2) scaffolding the mental habits of expert-like learners. BDI is an appropriate target for the application of educational theories of expertise. Designing better educational interventions for the prevention of BDI will require uncovering the hidden knowledge of expert surgeons and incorporating the processes of reinvestment and progressive problem solving that are inherent to expert performance.
NASA Technical Reports Server (NTRS)
Dittmar, James H.
1988-01-01
A simple barrier shielding model was used to estimate the amount of noise shielding on the fuselage that could result from installing a short duct around a wing-mounted advanced propeller. With the propeller located one-third of the duct length from the inlet, estimates for the maximum blade passing tone attenuation varied from 7 dB for a duct 0.25 propeller diameter long to 16.75 dB for a duct 1 diameter long. Attenuations for the higher harmonics would be even larger because of their shorter wavelengths relative to the duct length. These estimates show that the fuselage noise reduction potential of a ducted compared with an unducted propeller is significant. Even more reduction might occur if acoustic attenuation material were installed in the duct.
Coupled parametric design of flow control and duct shape
NASA Technical Reports Server (NTRS)
Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)
2009-01-01
A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.
NASA Technical Reports Server (NTRS)
Runnels, J. N.; Gupfa, A.
1973-01-01
Augmentor wing ducting system studies conducted on a valveless system configuration that provides cruise thrust from the augmentor nozzles have shown that most of the duct system pressure loss would occur in the strut-wing duct y-junction and the wing duct-augmentor lobe nozzles. These components were selected for development testing over a range of duct Mach numbers and pressure ratios to provide a technical basis for predicting installed wing thrust loading and for evaluating design wing loading of a particular wing aspect ratios. The flow characteristics of ducting components with relatively high pressure loss coefficients were investigated. The turbulent pressure fluctuations associated with flows at high Mach numbers were analyzed to evaluate potential duct fatigue problems.
Low-grade salivary duct carcinoma or low-grade intraductal carcinoma? Review of the literature.
Kuo, Ying-Ju; Weinreb, Ilan; Perez-Ordonez, Bayardo
2013-07-01
Low-grade salivary duct carcinoma (LG-SDC) is a rare neoplasm characterized by predominant intraductal growth, luminal ductal phenotype, bland microscopic features, and favorable clinical behavior with an appearance reminiscent of florid to atypical ductal hyperplasia to low grade intraductal breast carcinoma. LG-SDC is composed of multiple cysts, cribriform architecture with "Roman Bridges", "pseudocribriform" proliferations with floppy fenestrations or irregular slits, micropapillae with epithelial tufts, fibrovascular cores, and solid areas. Most of the tumor cells are small to medium sized with pale eosinophilic cytoplasm, and round to oval nuclei, which may contain finely dispersed or dark condensed chromatin. Foci of intermediate to high grade atypia, and invasive carcinoma or micro-invasion have been reported in up to 23 % of cases. The neoplastic cells have a ductal phenotype with coexpression of keratins and S100 protein and are surrounded by a layer of myoepithelial cells in non-invasive cases. The main differential diagnosis of LG-SDC includes cystadenoma, cystadenocarcinoma, sclerosing polycystic adenosis, salivary duct carcinoma in situ/high-grade intraductal carcinoma, and papillary-cystic variant of acinic cell carcinoma. There is no published data supporting the continuous classification of LG-SDC as a variant of cystadenocarcinoma. Given that most LG-SDC are non-invasive neoplasms; the terms "cribriform cystadenocarcinoma" and LG-SDC should be replaced by "low-grade intraductal carcinoma" (LG-IDC) of salivary gland or "low-grade intraductal carcinoma with areas of invasive carcinoma" in those cases with evidence of invasive carcinoma.
Sai, Jin Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio; Maehara, Tadayuki
2009-03-01
The International Consensus Guidelines are helpful for the management of branch-duct intraductal papillary mucinous neoplasms (IPMNs), because they allow us to exclude malignancy. However, it is not possible to predict malignancy with certainty, and further preoperative differentiation between benign and malignant IPMNs is required to avoid the false-positive results. To examine the usefulness of pancreatic-duct-lavage cytology by using an originally designed double-lumen catheter for discriminating benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines. Pancreatic-duct-lavage cytology was investigated in 24 patients with branch-duct IPMNs who underwent surgical resection based on the International Consensus Guidelines, namely, they either had intramural nodules or the ectatic branch duct was >30 mm in diameter. Single-center retrospective study. Academic medical center. The sensitivity and specificity of pancreatic-duct-lavage cytology for discriminating benign from malignant IPMNs. More than 30 mL of pancreatic-duct-lavage fluid was obtained from each patient, and there were no patients with noninformative results. The sensitivity, specificity, positive predictive value, and negative predictive value of the cytologic diagnosis were 78%, 93%, 88%, and 88%, respectively. Single-center and small number of patients. Pancreatic-duct-lavage cytology can improve differentiation between benign and malignant IPMNs of the branch-duct type in candidates for surgical resection based on the International Consensus Guidelines.
Voluntary and involuntary ligature of the bile duct in iatrogenic injuries: a nonadvisable approach.
Mercado, Miguel Angel; Chan, Carlos; Jacinto, Juan Carlos; Sanchez, Norberto; Barajas, Alexandra
2008-06-01
Bile duct injuries related to laparoscopic and/or open cholecystectomy are a frequent finding and require surgical treatment. Complete obstruction is due to either intentionally or unintentionally placed ligatures or clips. The intentional application is usually performed to "facilitate identification of the duct by bile duct dilation." Considering that we are a national referral center for such injuries, we decided to analyze our cases of voluntary and involuntary duct ligation after iatrogenic bile duct injury. We reviewed the files of patients with voluntary or involuntary bile duct ligation. Results of preoperative evaluation of the ducts, operative treatment, and postoperative results were analyzed. A total of 413 patients were included. Forty-five patients presented with complete obstruction. In 15 cases, the ligature was intentional, and in 30 cases, occlusion was involuntary. Bile duct dilation (>10 mm) was demonstrated in one case of voluntary (6%) and three cases of involuntary ligations (10%). The remaining cases in both groups had no duct dilation and developed necrosis at the blinded duct and leakage proximal to the ligature, with different degrees of bilioperitoneum and/or biloma. In all cases, a Roux-en-Y hepatojejunostomy was performed. Bile duct ligature produces dilation in a very small number of patients (less than 10%) and usually produces necrosis of the blinded stump with subsequent bile leakage. Placement of a subhepatic drain and transference of the patient to a qualified center for reconstruction is the best approach if the primary surgeon is not able to do the repair.
Ojima, Jun
2017-03-28
In a job site, a portable fan is often used to ventilate a confined space. When a portable fan is applied to such a space, the actual ventilation flow rate must be accurately estimated in advance because the safety level of contaminant and oxygen concentrations in the space will determine the ventilation requirements. When a portable fan is used with a flexible duct, the actual flow rate of the fan decreases due to the friction and duct bending loss of the duct. Intending to show the decline of a fan performance, the author conducted laboratory experiments and reported the quantitative effect of the friction and duct bending loss of a flexible duct to the flow rate of a portable fan. Four commercial portable fans of different specifications were procured for the experiments, and the decline of the performance of each portable fan due to the friction loss etc. of a connected flexible duct was investigated by measuring actual flow rate. The flow rate showed an obvious decrease from the rated flow rate when a flexible duct was connected. Connection of a straight polyester flexible duct and a straight aluminum flexible duct reduced the flow rates to 81.2 - 52.9% and less than 50%, respectively. The flow rate decreased with an increase of the bend angle of the flexible duct. It is recommended that flow rate check of a portable fan should be diligently carried out in every job site.
Leal-Leyte, Pilar; McKenna, Greg J; Ruiz, Richard M; Anthony, Tiffany L; Saracino, Giovanna; Giuliano, Testa; Klintmalm, Goran B; Kim, Peter Tw
2018-04-10
Introduction Bile duct size discrepancy in liver transplantation may increase the risk of biliary complications. The aim of this study was to evaluate the safety and outcomes of the eversion bile duct anastomosis technique in deceased donor liver transplantation (DDLT) with duct to duct anastomosis. Methods A total of 210 patients who received a DDLT with duct to duct anastomosis from 2012 to 2017 were divided into two groups: those who had eversion bile duct anastomosis (N=70) and standard bile duct anastomosis (N=140). Biliary complications rates were compared between the two groups. Results There was no difference in the cumulative incidence of biliary strictures (P=0.20) and leaks (P=0.17) between the two groups. The biliary complication rate in the eversion group was 14.3% and 11.4% in the standard anastomosis group. All the biliary complications in the eversion group were managed with endoscopic stenting. A severe size mismatch (≥3:1 ratio) was associated with a significantly higher incidence of biliary strictures (44.4%) compared to 2:1 ratio (8.2%), (P=0.002). Conclusion The use of the eversion technique is a safe alternative for bile duct discrepancy in deceased donor liver transplantation; however, severe bile duct size mismatch may be a risk factor for biliary strictures with such technique. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.
Optical architecture design for detection of absorbers embedded in visceral fat.
Francis, Robert; Florence, James; MacFarlane, Duncan
2014-05-01
Optically absorbing ducts embedded in scattering adipose tissue can be injured during laparoscopic surgery. Non-sequential simulations and theoretical analysis compare optical system configurations for detecting these absorbers. For absorbers in deep scattering volumes, trans-illumination is preferred instead of diffuse reflectance. For improved contrast, a scanning source with a large area detector is preferred instead of a large area source with a pixelated detector.
Optical architecture design for detection of absorbers embedded in visceral fat
Francis, Robert; Florence, James; MacFarlane, Duncan
2014-01-01
Optically absorbing ducts embedded in scattering adipose tissue can be injured during laparoscopic surgery. Non-sequential simulations and theoretical analysis compare optical system configurations for detecting these absorbers. For absorbers in deep scattering volumes, trans-illumination is preferred instead of diffuse reflectance. For improved contrast, a scanning source with a large area detector is preferred instead of a large area source with a pixelated detector. PMID:24877008
Numerical Simulation of Dual-Mode Scramjet Combustors
NASA Technical Reports Server (NTRS)
Rodriguez, C. G.; Riggins, D. W.; Bittner, R. D.
2000-01-01
Results of a numerical investigation of a three-dimensional dual-mode scramjet isolator-combustor flow-field are presented. Specifically, the effect of wall cooling on upstream interaction and flow-structure is examined for a case assuming jet-to-jet symmetry within the combustor. Comparisons are made with available experimental wall pressures. The full half-duct for the isolator-combustor is then modeled in order to study the influence of side-walls. Large scale three-dimensionality is observed in the flow with massive separation forward on the side-walls of the duct. A brief review of convergence-acceleration techniques useful in dual-mode simulations is presented, followed by recommendations regarding the development of a reliable and unambiguous experimental data base for guiding CFD code assessments in this area.
Large bilateral seminal vesicle calculi presenting with spermolithiasis.
Williams, Sarah Anne; Christodoulidou, Michelle; Nigam, Raj
2017-06-02
A 34-year-old male presented with an 8-month history of passing increasingly painful 'grit' in his ejaculate. Semen analysis was normal as were urinary and blood tests. T1-weighted MRI revealed several bilateral high-signal areas measuring up to 1 cm in diameter, located in the seminal vesicles. These were confirmed as calculi on T2-weighted imaging and a seminal vesiculogram, with no drainage from the left ejaculatory duct and only minimal from the right duct. He is currently awaiting a robot-assisted laparoscopic vesiculotomy after completion of family. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
ABSCESSES OF THE BREAST—Recurring Lesions in the Areolar Area
Kilgore, Alson R.; Fleming, Ruth
1952-01-01
Subareolar abscesses beginning either in infected skin glands or in breast ducts have an extraordinary tendency to recur and to be resistant to treatment. About three-fourths of 64 patients observed had from one to many recurrences of abscess after either spontaneous or surgical drainage, and many even after wide excision of scar in an interval of quiescence. The most successful of a number of methods of treatment used was wide removal of scar and underlying chronic abscess cavity combined with removal of the ampulla and mouth of a connecting duct. In a substantial number, after either drainage or unsuccessful excision, the process gradually subsided over a period of months or years. Cancer has not been observed in any of the 64 patients. PMID:12988056
Reciprocity principle in duct acoustics
NASA Technical Reports Server (NTRS)
Cho, Y.-C.
1979-01-01
Various reciprocity relations in duct acoustics have been derived on the basis of the spatial reciprocity principle implied in Green's functions for linear waves. The derivation includes the reciprocity relations between mode conversion coefficients for reflection and transmission in nonuniform ducts, and the relation between the radiation of a mode from an arbitrarily terminated duct and the absorption of an externally incident plane wave by the duct. Such relations are well defined as long as the systems remain linear, regardless of acoustic properties of duct nonuniformities which cause the mode conversions.
On Computations of Duct Acoustics with Near Cut-Off Frequency
NASA Technical Reports Server (NTRS)
Dong, Thomas Z.; Povinelli, Louis A.
1997-01-01
The cut-off is a unique feature associated with duct acoustics due to the presence of duct walls. A study of this cut-off effect on the computations of duct acoustics is performed in the present work. The results show that the computation of duct acoustic modes near cut-off requires higher numerical resolutions than others to avoid being numerically cut off. Duct acoustic problems in Category 2 are solved by the DRP finite difference scheme with the selective artificial damping method and results are presented and compared to reference solutions.
78 FR 67011 - Airworthiness Directives; PILATUS Aircraft Ltd. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
.... FOR FURTHER INFORMATION CONTACT: Doug Rudolph, Aerospace Engineer, FAA, Small Airplane Directorate... limited space available in this area the wiring harness can chafe against the RH flexible duct for the... 14 CFR 39.19. Send information to ATTN: Doug Rudolph, Aerospace Engineer, FAA, Small Airplane...
46 CFR 154.1205 - Mechanical ventilation system: Standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: Standards. 154.1205... Equipment Cargo Area: Mechanical Ventilation System § 154.1205 Mechanical ventilation system: Standards. (a) Each exhaust type mechanical ventilation system required under § 154.1200 (a) must have ducts for...
Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct
NASA Technical Reports Server (NTRS)
Kandula, Max
2011-01-01
The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.
Investigation in the 7-by-10 Foot Wind Tunnel of Ducts for Cooling Radiators within an Airplane Wing
NASA Technical Reports Server (NTRS)
Harris, Thomas A; Recant, Isidore G
1942-01-01
Report presents the results of an investigation made in the NACA 7 by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional-flow setup with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included.
Histochemical carbonic anhydrase in rat inner medullary collecting duct
NASA Technical Reports Server (NTRS)
Kleinman, J. G.; Bain, J. L.; Fritsche, C.; Riley, D. A.
1992-01-01
Rat inner medullary collecting duct (IMCD) secretes substantial amounts of H+. However, carbonic anhydrase (CA), a concomitant of H+ secretion, has been generally reported absent in this segment. To reexamine this problem, we investigated CA and the morphological phenotypes of cells comprising the IMCD by CA histochemistry, using a modified Hansson technique with light and electron microscopy. Throughout the medulla, tubule cells exhibit histochemical CA activity. In the initial third of the inner medulla, a small proportion have features of intercalated cells and demonstrate some degree of CA activity. However, the majority population in the early portions of the IMCD appears to consist of principal cells. These also show CA staining of widely variable intensity, both among and within cells. A third cell type, previously called "IMCD cells", appears in the middle portion of the IMCD and is the only cell type present near the papilla tip. In contrast to previous reports, these "IMCD cells" have histochemical CA staining, also of highly variable intensity. These results demonstrate that stainable carbonic anhydrase to support acidification is present throughout the rat IMCD, both in intercalated cells and in some cells clearly not of this type. Therefore, the presence of CA is not specific for the intercalated cell type and suggests that other cell types may participate in acid secretion in IMCD.
NASA Astrophysics Data System (ADS)
Sun, Zheng; Ning, Hui; Song, Shihui; Yan, Dongmei
2016-10-01
Nocturnal radiative cooling is a main driver for atmospheric duct formation. Within this atmospheric process, the impacts of intermittent turbulence on ducting have seldom been studied. In this paper, we reported two confusing ducting events observed in the early morning in August 2014 over Bosten Lake, China, when a stable boundary layer (SBL) still survived, by using tethered high-resolution GPS radiosondes. Elevated ducts with strong humidity inversions were observed during the balloon ascents but were absent during observations made upon the balloon descents several minutes later. This phenomenon was initially hypothesized to be attributable to turbulence motions in the SBL, and the connection between the turbulence event and the radar duct was examined by the statistical Thorpe method. Turbulence patches were detected from the ascent profiles but not from the descent profiles. The possible reasons for the duct formation and elimination were discussed in detail. The turbulent transport of moisture in the SBL and the advection due to airflows coming from the lake are the most probable reasons for duct formation. In one case, the downward transport of moisture by turbulence mixing within a Kelvin-Helmholtz billow at the top of the low-level jet resulted in duct elimination. In another case, the passage of density currents originating from the lake may have caused the elimination of the duct. Few studies have attempted to associate intermittent turbulence with radar ducts; thus, this work represents a pioneering study into the connection between turbulent events and atmospheric ducts in a SBL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beal, D.; McIlvaine , J.; Fonorow, K.
2011-11-01
This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition tomore » enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.« less
Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles
NASA Astrophysics Data System (ADS)
Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.
2012-03-01
Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).
Modelling gas dynamics in 1D ducts with abrupt area change
NASA Astrophysics Data System (ADS)
Menina, R.; Saurel, R.; Zereg, M.; Houas, L.
2011-09-01
Most gas dynamic computations in industrial ducts are done in one dimension with cross-section-averaged Euler equations. This poses a fundamental difficulty as soon as geometrical discontinuities are present. The momentum equation contains a non-conservative term involving a surface pressure integral, responsible for momentum loss. Definition of this integral is very difficult from a mathematical standpoint as the flow may contain other discontinuities (shocks, contact discontinuities). From a physical standpoint, geometrical discontinuities induce multidimensional vortices that modify the surface pressure integral. In the present paper, an improved 1D flow model is proposed. An extra energy (or entropy) equation is added to the Euler equations expressing the energy and turbulent pressure stored in the vortices generated by the abrupt area variation. The turbulent energy created by the flow-area change interaction is determined by a specific estimate of the surface pressure integral. Model's predictions are compared with 2D-averaged results from numerical solution of the Euler equations. Comparison with shock tube experiments is also presented. The new 1D-averaged model improves the conventional cross-section-averaged Euler equations and is able to reproduce the main flow features.
Aquaporin-2 Regulation in Health and Disease
Radin, M. Judith; Yu, Ming-Jiun; Stoedkilde, Lene; Miller, R. Lance; Hoffert, Jason D.; Frokiaer, Jorgen; Pisitkun, Trairak; Knepper, Mark A.
2012-01-01
Aquaporin-2 (AQP2), the vasopressin-regulated water channel of the renal collecting duct, is dysregulated in numerous water balance disorders in humans and animals including those associated with polyuria (e.g. urinary tract obstruction, hypokalemia, inflammation, and lithium toxicity) and dilutional hyponatremia (e.g. SIADH). Normal regulation of AQP2 by vasopressin involves two independent regulatory mechanisms: 1) short-term regulation of AQP2 trafficking to and from the apical plasma membrane, and 2) long term regulation of the total abundance of the AQP2 protein in the cells. Most water balance disorders are the result of dysregulation of processes that regulate the total abundance of AQP2 in collecting duct cells. In general, the level of AQP2 in a collecting duct cell is determined by a balance between production via translation of AQP2 mRNA and removal via degradation and/or secretion into the urine in exosomes. AQP2 abundance increases in response to vasopressin chiefly due to increased translation subsequent to increases in AQP2 mRNA. Vasopressin-mediated regulation AQP2 gene transcription is poorly understood, although several transcription factor binding elements in the 5’ flanking region of the AQP2 gene have been identified and candidate transcription factors corresponding to these element have been discovered in proteomics studies. Here we review progress in this area and discuss elements of vasopressin signaling in the collecting duct that may impinge on regulation of AQP2 in health and in the context of examples of polyuric diseases. PMID:23130944
Total rupture of hydatid cyst of liver in to common bile duct: a case report.
Robleh, Hassan; Yassine, Fahmi; Driss, Khaiz; Khalid, Elhattabi; Fatima-Zahra, Bensardi; Saad, Berrada; Rachid, Lefriyekh; Abdalaziz, Fadil; Najib, Zerouali Ouariti
2014-01-01
Rupture of hydatid liver cyst into biliary tree is frequent complications that involve the common hepatic duct, lobar biliary branches, the small intrahepatic bile ducts,but rarely rupture into common bile duct. The rupture of hydatid cyst is serious life threating event. The authors are reporting a case of total rupture of hydatid cyst of liver into common bile duct. A 50-year-old male patient who presented with acute cholangitis was diagnosed as a case of totally rupture of hydatid cyst on Abdominal CT Scan. Rupture of hydatid cyst of liver into common bile duct and the gallbladder was confirmed on surgery. Treated by cholecystectomy and T-tube drainage of Common bile duct.
Gál, Adrián Róbert; Kalmár-Nagy, Károly; Fincsur, András; Horváth, Örs Péter; Vereczkei, András
2018-03-01
The authors present a case of a 67-year-old male patient, who previously had been diagnosed with a malignant liver tumor localized in segment II. He underwent bisegmentectomy (II and III) and partial IV segmentectomy. After the primary surgery jaundice developed, the level of bilirubin increased and after several imaging modalities reoperation was indicated. During the surgery a rare bile duct anatomy variant was found. The right hepatic duct joined the left duct in the parenchyma of the left lobe, and was ligated at the resection. As the liver hilum was not explored, the absence of the right duct was not discovered. Reconstruction of the biliary system was accomplished by a Roux-en-Y loop.
Preliminary Investigation of Curved Liner Sample in the NASA LaRC Curved Duct Test Rig
NASA Technical Reports Server (NTRS)
Gerhold, Carl H.; Jones, Michael G.; Brown, Martha C.
2007-01-01
This viewgraph presentation reviews the preliminary investigation of the curved liner sample in the NASA LaRC Curved Duct Test Rig (CDTR). It reviews the purpose of the Curved Duct Test Rig. Its purpose is to develop capability to investigate acoustic and aerodynamic properties in ducts. It has several features to accomplish that purpose: (1) Large scale (2) Flow rate to M = 0.275 (3) Higher order mode control (4) Curved flow path (5) Adaptable test section (6) Flexible test configurations. The liner has minimal effect on turbulence or boundary layer growth in duct. The curved duct sample attenuation is affected by mode scattering. In conclusion, the CDTR is valid tool for aerodynamic and acoustic evaluation of duct treatment
Post-Tensioning Duct Air Pressure Testing Effects on Web Cracking
DOT National Transportation Integrated Search
2015-01-01
Nevada Department of Transportation (NDOT) post-tensioned concrete bridges have experienced web cracking near the post-tensioning ducts during the construction process. The ducts were air pressure tested to ensure the duct can successfully be grouted...
Cholangiocarcinoma in a middle-aged patient working at a printing plant.
Tanaka, Shogo; Fukumoto, Nobusuke; Ohno, Kohichi; Tanaka, Sayaka; Ohsawa, Masahiko; Yamamoto, Takatsugu; Nakanuma, Yasuni; Kuboo, Shoji
2014-06-01
A 39-year-old male with elevated serum transferases consulted our hospital in September 2010. Since 1999, he had worked at a printing company using organic solvents. Cholangiography revealed stenosis of the left hepatic duct with peripheral dilation, stricture of the right hepatic duct, and irregularity of the extrahepatic bile duct. As a preoperative diagnosis of sclerosing cholangitis and cholangiocarcinoma was made, extended left hepatectomy with resection of the extrahepatic bile duct and anastomosis of the anterior and posterior branches of the bile duct and the jejunum (Roux-en Y reconstruction) were performed. A histological examination showed papillary carcinoma of the medial hepatic bile duct with intraductal growth, and biliary intraepithelial neoplasia-2/3 lesions from the medial hepatic bile duct to the right hepatic and the common bile ducts. Chronic cholangitis was shown around the tumors. Postoperatively, the patient was treated with adjuvant chemo-radiation, and he is doing well 30 months after the operation, without recurrence. Unknown causes, including exposure to organic solvents, might have induced chronic bile duct injury and contributed to the development of cholangiocarcinoma.
Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh
2016-01-01
Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones. PMID:27047698
Zhang, Bo; Xu, Jin; Liu, Chen; Long, Jiang; Liu, Liang; Xu, Yongfeng; Wu, Chuntao; Luo, Guopei; Ni, Quanxing; Li, Min; Yu, Xianjun
2013-01-01
Pancreaticojejunostomy is the key procedure of pancreaticoduodenectomy. Our study introduced a new pancreaticojejunal (PJ) anastomosis named “papillary-like main pancreatic duct invaginated” pancreaticojejunostomy. Nighty-two patients underwent pancreaticojejunostomy with either conventional duct-to-mucosa pancreaticojejunostomy or the new “papillary-like main pancreatic duct invaginated” techniques were analyzed retrospectively from January 2010 to September 2012. The incidence of pancreatic fistula was 15.7% (8/51) for the “papillary-like main pancreatic duct invaginated” group and 19.5% (8/41) for the duct-to-mucosa fashion respectively. It is noteworthy that the rate of grade B/C postoperative pancreatic fistula (POPF) in the “papillary-like main pancreatic duct invaginated” group was significantly lower than that of the duct-to-mucosa group (P = 0.039). There were no differences in the incidence of postoperative morbidity and mortality such as postoperative hemorrhage, delayed gastric emptying or remnant pancreatitis. The “papillary-like main pancreatic duct invaginated” pancreaticojejunostomy could provide a feasible option to pancreatic surgeons for patients with normal soft pancreas. PMID:23797701
Amin, Arpit; Zhurov, Yuriy; Ibrahim, George; Maffei, Anthony; Giannone, Jonathan; Cerabona, Thomas; Kaul, Ashutosh
2016-01-01
Mirizzi syndrome has been defined in the literature as common bile duct obstruction resulting from calculi within Hartmann's pouch or cystic duct. We present a case of a 78-year-old female, who developed postcholecystectomy Mirizzi syndrome from a remnant cystic duct stone. Diagnosis of postcholecystectomy Mirizzi syndrome was made on endoscopic retrograde cholangiography (ERCP) performed postoperatively. The patient was treated with a novel strategy by combining advanced endoscopic and laparoscopic techniques in three stages as follows: Stage 1 (initial presentation): endoscopic sphincterotomy with common bile duct stent placement; Stage 2 (6 weeks after Stage 1): laparoscopic ultrasonography to locate the remnant cystic duct calculi followed by laparoscopic retrieval of the calculi and intracorporeal closure of cystic duct stump; Stage 3 (6 weeks after Stage 2): endoscopic removal of common bile duct stent along with performance of completion endoscopic retrograde cholangiogram. In addition, we have performed an extensive review of the various endoscopic and laparoscopic management techniques described in the literature for the treatment of postcholecystectomy syndrome occurring from retained cystic duct stones.
2013-12-01
depression, tropical storm , hurricane, extratropical cyclone, subtropical depression, subtropical storm , a low of no category, tropical wave, disturbance or...surface-based ducts, and elevated ducts. We further separate the duct occurrence based on the location relative to their respective storms . Based...on the number of soundings in different types of tropical disturbances, we chose to further analyze duct conditions in hurricanes and tropical storms
Mucocele of the cystic duct remnant after orthotopic liver transplant: a problem revisited.
Chatterjee, Suvadip; Das, Debasish; Hudson, Mark; Bassendine, Margaret Fiona; Scott, John; Oppong, Kofi Ernest; Sen, Gourab; French, Jeremy J
2011-06-01
Mucocele of the cystic duct remnant is an uncommon hepatobiliary complication of a liver transplant. Current practice usually involves either excising the cystic duct, or incorporating the distal end of the transected cystic duct into the suture line of the biliary anastomosis to ensure drainage. We report a patient who developed cystic duct remnant mucocele after the latter approach was adopted. We believe that this is likely related to delayed anastomotic stricturing, which prevented draining from the remnant cystic duct. We also discuss the incidence, pathology, investigations, and treatment of this condition.
Beach, R.J.; Benett, W.J.
1994-04-26
A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.
Simple resection of the lesion bile duct branch for treatment of regional hepatic bile duct stones
Enliang, Li; Rongshou, Wu; Shidai, Shi; Jingling, Zhang; Qian, Feng; Wenjun, Liao; Linquan, Wu
2017-01-01
Abstract To evaluate the effectiveness and safety of simple resections of bile duct branch lesions for the treatment of regional hepatic bile duct stones. A retrospective analysis of the clinical data from patients in our hospital from November 2008 to November 2015, who only underwent a simple resection of the lesion bile duct branch. The patients’ clinical characteristics, surgical features, postoperative complications, stone clear rate, residual stone rate, and recurrence stone rate were analyzed. This study of 32 patients included 13 males and 19 females with intrahepatic bile duct stones confined to the right hepatic bile duct branch. The intraoperative blood loss, operation time, and postoperative hospital stay were 478.0 ± 86.5, 210.7 ± 6.6, and 10.8 ± 3.5, respectively. Postoperative complications occurred in 6 patients (18.8%), all of whom recovered with conservative management. There were no deaths during hospitalization. The intraoperative stone clearance rate was 95.8%. Three patients had a recurrence of stones at a mean of 22 months of follow-up (range, 4–36 months). Simple resection of bile duct branch lesions is safe and feasible for patients who have regional hepatic bile duct stones limited to the right hepatic bile duct branches. PMID:28682899
Reference values of MRI measurements of the common bile duct and pancreatic duct in children.
Gwal, Kriti; Bedoya, Maria A; Patel, Neal; Rambhatla, Siri J; Darge, Kassa; Sreedharan, Ram R; Anupindi, Sudha A
2015-07-01
Magnetic resonance imaging/cholangiopancreatography (MRI/MRCP) is now an essential imaging modality for the evaluation of biliary and pancreatic pathology in children, but there are no data depicting the normal diameters of the common bile duct (CBD) and pancreatic duct. Recognition of abnormal duct size is important and the increasing use of MRCP necessitates normal MRI measurements. To present normal MRI measurements for the common bile duct and pancreatic duct in children. In this retrospective study we searched all children ages birth to 10 years in our MR urography (MRU) database from 2006 until 2013. We excluded children with a history of hepatobiliary or pancreatic surgery. We stratified 204 children into five age groups and retrospectively measured the CBD and the pancreatic duct on 2-D axial and 3-D coronal T2-weighted sequences. We performed statistical analysis, using logistic and linear regressions to detect the age association of the visibility and size of the duct measurements. We used non-parametric tests to detect gender and imaging plane differences. Our study included 204 children, 106 (52%) boys and 98 (48%) girls, with a median age of 33 months (range 0-119 months). The children were distributed into five age groups. The common bile duct was visible in all children in all age groups. The pancreatic duct was significantly less visible in the youngest children, group 1 (54/67, 80.5%; P = 0.003) than in the oldest children, group 5 (22/22, 100%). In group 2 the pancreatic duct was seen in 19/21 (90.4%), in group 3 52/55 (94.5%), and in group 4 39/39 (100%). All duct measurements increased with age (P < 0.001; r-value > 0.423), and the incremental differences between ages were significant. The measurement variations between the axial and coronal planes were statistically significant (P < 0.001); however these differences were fractions of millimeters. For example, in group 1 the mean coronal measurement of the CBD was 2.1 mm and the axial measurement was 2.0 mm; the mean coronal measurement of the pancreatic duct was 0.9 mm and the axial measurement was 0.8 mm. Our study provides normative measurements for the common bile duct and pancreatic duct for children up to age 10 years. The upper limits of the CBD and pancreatic duct increase with age, and the values range 1.1-4.0 mm for the CBD and 0.6-1.9 mm for the pancreatic duct.
Code of Federal Regulations, 2012 CFR
2012-07-01
... exhaust ventilation when used as described in (a) shall be designed to prevent dispersion into the air of... shall be so designed that dusts, fumes, mists, vapors, or gases are not drawn through the work area of employees. (c) Design and operation. Exhaust fans, jets, ducts, hoods, separators, and all necessary...
A Plug-and-Play Duct System Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beach, Robert; Dickson, Bruce; Grisolia, Anthony
This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less
Choi, Jin Woo; Kim, Kyoung Won; Kim, Ah Young; Kim, Pyo Nyun; Ha, Hyun Kwon; Lee, Moon-Gyu
2003-01-01
Objective To describe the anatomical variation occurring in intrahepatic bile ducts (IHDs) in terms of their branching patterns, and to determine the frequency of each variation. Materials and Methods The study group consisted of 300 consecutive donors for liver transplantation who underwent intraoperative cholangiography. Anatomical variation in IHDs was classified according to the branching pattern of the right anterior and right posterior segmental duct (RASD and RPSD, respectively), and the presence or absence of the first-order branch of the left hepatic duct (LHD), and of an accessory hepatic duct. Results The anatomy of the intrahepatic bile ducts was typical in 63% of cases (n=188), showed triple confluence in 10% (n=29), anomalous drainage of the RPSD into the LHD in 11% (n=34), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 6% (n=19), anomalous drainage of the RPSD into the cystic duct in 2% (n=6), drainage of the right hepatic duct (RHD) into the cystic duct (n=1), the presence of an accessory duct leading to the CHD or RHD in 5% (n=16), individual drainage of the LHD into the RHD or CHD in 1% (n=4), and unclassified or complex variation in 1% (n=3). Conclusion The branching pattern of IHDs was atypical in 37% of cases. The two most common variations were drainage of the RPSD into the LHD (11%) and triple confluence of the RASD, RPSD and LHD (10%). PMID:12845303
Anatomy of the lactating human breast redefined with ultrasound imaging
Ramsay, DT; Kent, JC; Hartmann, RA; Hartman, PE
2005-01-01
The aim of this study was to use ultrasound imaging to re-investigate the anatomy of the lactating breast. The breasts of 21 fully lactating women (1–6 months post partum) were scanned using an ACUSON XP10 (5–10 MHz linear array probe). The number of main ducts was measured, ductal morphology was determined, and the distribution of glandular and adipose tissue was recorded. Milk ducts appeared as hypoechoic tubular structures with echogenic walls that often contained echoes. Ducts were easily compressed and did not display typical sinuses. All ducts branched within the areolar radius, the first branch occurring 8.0 ± 5.5 mm from the nipple. Duct diameter was 1.9 ± 0.6 mm, 2.0 ± 90.7 mm and the number of main ducts was 9.6 ± 2.9, 9.2 ± 2.9, for left and right breast, respectively. Milk ducts are superficial, easily compressible and echoes within the duct represent fat globules in breastmilk. The low number and size of the ducts, the rapid branching under the areola and the absence of sinuses suggest that ducts transport breastmilk, rather than store it. The distribution of adipose and glandular tissue showed wide variation between women but not between breasts within women. The proportion of glandular and fat tissue and the number and size of ducts were not related to milk production. This study highlights inconsistencies in anatomical literature that impact on breast physiology, breastfeeding management and ultrasound assessment. PMID:15960763
NASA Astrophysics Data System (ADS)
Yang, Cheng; Fang, Yi; Zhao, Chao; Zhang, Xin
2018-06-01
A duct acoustics model is an essential component of an impedance eduction technique and its computation cost determines the impedance measurement efficiency. In this paper, a model is developed for the sound propagation through a lined duct carrying a uniform mean flow. In contrast to many existing models, the interface between the liner and the duct field is defined with a modified Ingard-Myers boundary condition that takes account of the effect of the boundary layer above the liner. A mode-matching method is used to couple the unlined and lined duct segments for the model development. For the lined duct segment, the eigenvalue problem resulted from the modified boundary condition is solved by an integration scheme which, on the one hand, allows the lined duct modes to be computed in an efficient manner, and on the other hand, orders the modes automatically. The duct acoustics model developed from the solved lined duct modes is shown to converge more rapidly than the one developed from the rigid-walled duct modes. Validation against the experiment data in the literature shows that the proposed model is able to predict more accurately the liner performance measured by the two-source method. This, however, cannot be made by a duct acoustics model associated with the conventional Ingard-Myers boundary condition. The proposed model has the potential to be integrated into an impedance eduction technique for more reliable liner measurement.
Reconstruction of Bile Duct Injury and Defect with the Round Ligament.
Dokmak, Safi; Aussilhou, Béatrice; Ragot, Emilia; Tantardini, Camille; Cauchy, François; Ponsot, Philippe; Belghiti, Jacques; Sauvanet, Alain; Soubrane, Olivier
2017-09-01
Lateral injury of the bile duct can occur after cholecystectomy, bile duct dissection, or exploration. If direct repair is not possible, conversion to bilioenteric anastomosis can be needed with the risk of long-term bile duct infections and associated complications. We developed a new surgical technique which consist of reconstructing the bile duct with the round ligament. The vascularized round ligament is completely mobilized until its origin and used for lateral reconstruction of the bile duct to cover the defect. T tube was inserted and removed after few months. Patency of the bile duct was assessed by cholangiography, the liver function test and magnetic resonance imaging (MRI). Two patients aged 33 and 59 years old underwent lateral reconstruction of the bile duct for defects secondary to choledocotomy for stone extraction or during dissection for Mirizzi syndrome. The defects measured 2 and 3 cm and occupied half of the bile duct circumference. The postoperative course was marked by low output biliary fistula resolved spontaneously. In one patient, the T tube was removed at 3 months after surgery and MRI at 9 months showed strictly normal aspect of the bile duct with normal liver function test. The second patient is going very well 2 months after surgery and the T tube is closed. Lateral reconstruction of the bile duct can be safely achieved with the vascularized round ligament. We will extend our indications to tubular reconstruction.
Nishi, Takeshi; Sato, Yoshitoshi; Hanaoka, Takuya; Takahashi, Takuya; Miura, Hiroshi; Takubo, Kenji
2018-01-01
Double cancers of the biliary tract system are rare. Most of these cancers are synchronous double cancers of the gall bladder and bile duct, associated with pancreaticobiliary maljunction (PBM). Synchronous double cancers of the extrahepatic bile duct without PBM are especially rare, and only 4 cases have been reported. A 78-year-old woman was admitted to our hospital for examination of hyperbilirubinemia and liver dysfunction. Contrast-enhanced abdominal computed tomography, Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography revealed 2 stenotic regions in the common bile duct: at its junction with the cystic duct and in the distal bile duct. No findings suggested PBM, such as a markedly long common channel. The diagnosis based on endoscopic brush cytology from both stricture portions was adenocarcinoma. The patient had a pylorus-preserving pancreaticoduodenectomy with regional lymph node resection. Macroscopically, there were 2 stenotic regions at the cystic duct junction and in the distal bile duct. Microscopically, the tumor at the junction of the cystic duct was a well-to-moderately differentiated adenocarcinoma. On the other hand, the tumor of the distal bile duct was a poorly differentiated adenocarcinoma. There was no evidence of communication between these 2 cancers. Double cancers of the extrahepatic bile duct without PBM are very rare. Therefore, an accurate diagnosis prior to surgery is necessary. Furthermore, this rare condition seems to be associated with a poor prognosis. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Miyagi, S; Kawagishi, N; Kashiwadate, T; Fujio, A; Tokodai, K; Hara, Y; Nakanishi, C; Kamei, T; Ohuchi, N; Satomi, S
2016-05-01
In living donor liver transplantation (LDLT), the recipient bile duct is thin and short. Bile duct complications often occur in LDLT, with persistent long-term adverse effects. Recently, we began to perform microsurgical reconstruction of the bile duct. The purpose of this study was to investigate the relationship between bile duct reconstruction methods and complications in LDLT. From 1991 to 2014, we performed 161 LDLTs (pediatric:adult = 90:71; left lobe:right lobe = 95:66). In this study, we retrospectively investigated the initial bile duct complications in LDLT and performed univariate and multivariate analyses to identify the independent risk factors for complications. The most frequent complication was biliary stricture (9.9%), followed by biliary leakage (6.8%). On univariate and multiple logistic regression analysis, the independent risk factors for biliary stricture were bile leakage (P = .0103) and recurrent cholangitis (P = .0077). However, there were no risk factors for biliary leakage on univariate analysis in our study. The reconstruction methods (hepaticojejunostomy or duct-to-duct anastomosis) and reconstruction technique (with or without microsurgery) were not risk factors for biliary stricture and leakage. In this study, the most frequent complication of LDLT was biliary stricture. The independent risk factors for biliary stricture were biliary leakage and recurrent cholangitis. Duct-to-duct anastomosis and microsurgical reconstruction of the bile duct were not risk factors for biliary stricture and leakage. Copyright © 2016 Elsevier Inc. All rights reserved.
A Plug-and-Play Duct System Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beach, R.; Dickson, B.; Grisolia, A.
2017-07-01
This report describes an air distribution system composed of a series of uniformly-sized ducts that terminate in rooms throughout the home and return to a central manifold, similar in fashion to a “home-run” cross-linked polyethylene plumbing system. With a well-designed manifold, each duct receives an equal static pressure potential for airflow from the air handling unit, and the number of needed ducts for each room are simply attached to fittings located on the manifold; in this sense, the system is plug-and-play (PnP). As indicated, all ducts in the PnP system are identical in size and small enough to fit inmore » the ceiling and wall cavities of a house (i.e., less than 3.5-in. outer diameter). These ducts are also more appropriately sized for the lower airflow requirements of modern, energy-efficient homes; therefore, the velocity of the air moving through the duct is between that of conventional duct systems (approximately 700 ft/min) and high-velocity systems (more than 1,500 ft/min) on the market today. The PnP duct system uses semi-rigid plastic pipes, which have a smooth inner wall and are straightforward to install correctly, resulting in a system that has minimal air leakage. However, plastic ducts are currently not accepted by code for use in residential buildings; therefore, the project team considered other duct materials for the system that are currently accepted by code, such as small-diameter, wirehelix, flexible ductwork.« less
Mockup Small-Diameter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke and A. Rudd
2016-05-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
Anatomic variations in intrahepatic bile ducts in a north Indian population.
Sharma, Vijay; Saraswat, Vivek Anand; Baijal, Sanjay Saran; Choudhuri, Gourdas
2008-07-01
In the present study, we described the anatomical variations in the branching patterns of intrahepatic bile ducts (IHD) and determined the frequency of each variation in north Indian patients. There are no data from India. The study group consisted of 253 consecutive patients (131 women) undergoing endoscopic retrograde cholangiograms for different indications. Anatomical variations in IHD were classified according to the branching pattern of the right anterior segmental duct (RASD) and the right posterior segmental duct (RPSD), presence or absence of first-order branch of left hepatic duct (LHD) and of an accessory hepatic duct. Anatomy of the IHD was typical in 52.9% of cases (n = 134), showing triple confluence in 11.46% (n = 29), anomalous drainage of the RPSD into the LHD in 18.2% (n = 46), anomalous drainage of the RPSD into the common hepatic duct (CHD) in 7.1% (n = 18), drainage of the right hepatic duct (RHD) into the cystic duct 0.4% (n = 1), presence of an accessory duct leading to the CHD or RHD in 4.7% (n = 12), individual drainage of the LHD into the RHD or CHD in 2.4% (n = 6), and unclassified or complex variations in 2.7% (n = 7). None had anomalous drainage of RPSD into the cystic duct. The branching pattern of IHD was atypical in 47% patients. The two most common variations were drainage of the RPSD into the LHD (18.2%) and triple confluence of the RASD, RPSD, and LHD (11.5%).
Sugimoto, Motokazu; Elliott, Irmina A; Nguyen, Andrew H; Kim, Stephen; Muthusamy, V Raman; Watson, Rabindra; Hines, O Joe; Dawson, David W; Reber, Howard A; Donahue, Timothy R
2017-01-18
According to the 2012 International Consensus Guidelines, the diagnostic criterion of intraductal papillary mucinous neoplasms (IPMNs) involving the main duct (MD IPMNs) or the main and branch ducts (mixed IPMNs) of the pancreatic system is a main pancreatic duct (MPD) diameter of 5.0 mm or greater on computed tomography (CT) or magnetic resonance imaging (MRI). However, surgical resection is recommended for patients with an MPD diameter of 10.0 mm or greater, which is characterized as a high-risk stigma. An MPD diameter of 5.0 to 9.0 mm is not an indication for immediate resection. To determine an appropriate cutoff (ie, one with high sensitivity and negative predictive value) of the MPD diameter on CT or MRI as a prognostic factor for malignant disease and to propose a new management algorithm for patients with MD or mixed IPMNs. This retrospective cohort study included 103 patients who underwent surgical resection for a preoperative diagnosis of MD or mixed IPMN and in whom IPMN was confirmed by surgical pathologic findings at a single institution from July 1, 1996, to December 31, 2015. Malignant disease was defined as high-grade dysplasia or invasive adenocarcinoma on results of surgical pathologic evaluation. An appropriate MPD diameter on preoperative CT or MRI to predict malignant disease was determined using a receiver operating characteristic curve analysis. The prognostic value of the new management algorithm that incorporated the new MPD diameter cutoff was evaluated. Among the 103 patients undergoing resection for an MD or mixed IPMN (59 men [57.3%]; 44 women [42.7%]; median [range] age, 71 [48-86] years), 64 (62.1%) had malignant disease. Diagnostic accuracy for malignant neoplasms was highest at an MPD diameter cutoff of 7.2 mm (area under the receiver operating characteristic curve, 0.70; 95% CI, 0.59-0.81). An MPD diameter of 7.2 mm or greater was also an independent prognostic factor for malignant neoplasms (odds ratio, 12.76; 95% CI, 2.43-66.88; P = .003) on logistic regression analysis after controlling for preoperative variables. The new management algorithm, which included an MPD diameter of 7.2 mm or greater as one of the high-risk stigmata, had a higher sensitivity (100%), negative predictive value (100%), and accuracy (66%) for malignant disease than the 2012 version of the International Consensus Guidelines (95%, 57%, and 63%, respectively). In this single-center, retrospective analysis, an MPD diameter of 7.2 mm was identified as an optimal cutoff for a prognostic factor for malignant disease in MD or mixed IPMN. These data support lowering the accepted criteria for MPD diameter when selecting patients for resection vs surveillance so as not to overlook cancer in IPMN.
Effects of partial portal vein arterialization on the hilar bile duct in a rat model.
Guo, Shao-Hua; Li, Chong-Hui; Chen, Yong-Liang; Song, Jian-Ning; Zhang, Ai-Qun; Zhou, Cheng
2011-10-01
Liver revascularization is frequently required during the enlarged radical operation for hilar cholangiocarcinoma involving the hepatic artery. Researchers have carried out a number of experiments applying partial portal vein arterialization (PVA) in clinical practice. In this study we aimed to establish a theoretical basis for clinical application of partial PVA and to investigate the effects of partial PVA on rat hilar bile duct and hepatic functions. Thirty rats were randomly and equally assigned into 3 groups: control (group A), hepatic artery ligation+bile duct recanalization (group B), and partial PVA+bile duct recanalization (group C). Proliferation and apoptosis of rat hilar bile duct epithelial cells, arteriolar counts of the peribiliary plexus (PBP) of the bile duct wall, changes in serum biochemistry, and pathologic changes in the bile duct were assessed 1 month after operation. The proliferation of hilar bile duct epithelial cells in group B was greater than in groups A and C (P<0.01). No apoptotic hilar bile duct epithelial cells were detected in any of the groups. The PBP arteriolar counts of the hilar bile duct wall were similar in groups A and C (P>0.05), but the count was lower in group B than in group A (P<0.01). No statistically significant differences in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase and albumin were found in the 3 groups. The gamma-glutamyltransferase value was higher in group B than in groups A and C (P<0.01). The hepatic tissues of groups A and C showed no significant abnormality. Chronic inflammatory changes in the hilar bile duct walls were observed only in group B. Partial PVA can restore the arterial blood supply of the hilar bile duct and significantly extenuate the injury to hilar bile duct epithelial cells resulting from hepatic artery ligation.
Da Vinci robot-assisted anatomic left hemihepatectomy and biliary reconstruction.
Wang, Zhifei; Liu, Quanda; Chen, Junzhou; Duan, Weihong; Zhou, Ningxin
2013-06-01
Since the introduction of Da Vinci robotic surgery, more and more complicated surgeries can now be performed robotically, yet there have been very few on robotic hepatectomy, especially when billiary reconstruction is involved. The video shows our initial experience with an anatomic hepatectomy using Da Vinci surgical robot. In this case, we also conducted billiary reconstruction due to the anatomic abnormality of bile duct, while applying the choledochoscopy. The preoperative diagnosis is primary liver carcinoma, tumor thrombi in bile duct, and hepatitis B. First, the gallbladder was resected, and cystic artery and duct were identified. After opening of the common bile duct above the junction, the choledochoscopy was performed. Tumor thrombi were found in common bile duct and left hepatic duct, and they were all removed. Left branches hepatic artery and portal vein were dissected, ligated, and divided. Thrombi in the left hepatic duct were removed also. After marking the cutting line along the ischemic boarder, liver parenchyma was transected using robotic harmonic scalpel. Branches of ducts were encountered and managed by either direct coagulating or dividing after clipping. The left hepatic vein was visualized, exposed, and divided during hepatectomy. Two T tubes were placed into common hepatic duct and the proximal cutting end of right anterior bile duct which was found to join the left hepatic duct, respectively. The operation went on successfully. The operation time was 410 minutes, the blood loss was 200 mL. The pathologic diagnosis was introductal papillary adenocarcinoma of left hepatic duct. The patient went on well postoperatively and was followed up for 22 months till now. Postoperative computed tomography examination showed no recurrence. Da Vinci-assisted robotic hepatectomy can be performed safely in the hands of experienced hepatobilliary surgeons, and choledochoscopy can be combined for bile duct exploration. With the advantages of Da Vinci robot system, complicated billiary reconstruction can be performed (http://links.lww.com/SLE/A74).
A novel technique of percutaneous stone extraction in choledocholithiasis after cholecystostomy.
Lim, Kyoung Hoon; Kim, Yong Joo
2013-05-01
To evaluate the technical feasibility and clinical efficacy of percutaneous common bile duct stone extraction via cystic duct after percutaneous cholecystostomy. Twenty-five consecutive patients with choledocholithiasis underwent percutaneous stone extraction under conscious sedation. The stones were extracted through the 12-Fr sheath using Wittich nitinol stone basket under fluoroscopic guidance via cystic duct after percutaneous trnas-hepatic cholecystostomy. Common bile duct stones were successfully removed in 22 of the 25 patients (88%) by this new technique. The causes of failure in three patients were bile leakage, hematoma of the gallbladder and failure of cystic duct cannulation. Cystic duct injury during this procedure did not occur and there was no post-procedure mortality. The mean period of indwelling catheter was 8.7±4.6 days and the mean duration of hospitalization was 13.4±5.9 days. Percutaneous commmon bile duct stone extraction via the cystic duct through percutaneous cholecystostomy route is effective and feasible for treating choledocholithiasis.
Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin
2013-04-21
At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.
Study of Gas Solid Flow Characteristics in Cyclone Inlet Ducts of A300Mwe CFB Boiler
NASA Astrophysics Data System (ADS)
Tang, J. Y.; Lu, X. F.; Lai, J.; Liu, H. Z.
Gas solid flow characteristics in cyclone's inlet duct of a 300MW CFB boiler were studied in a cold circulating fluidized bed (CFB) experimental setup according to a 410t/h CFB boiler with a scale of 10∶1. Tracer particles were adopted in the experiment and their motion trajectories in the two kinds of cyclone's inlet ducts were photographed by a high-speed camera. By analyzing the motion trajectories of tracer particles, acceleration performance of particle phases in the two inlet ducts was obtained. Results indicate that the acceleration performance of particles in the long inlet duct is better than that in the short inlet duct, but the pressure drop of the long inlet duct is higher. Meanwhile, under the same operating conditions, both the separation efficiency and the pressure drop of the cyclone are higher when the cyclone is connected with the long inlet duct. Figs 11, Tabs 4 and refs 10.
Cherian, Mathew Pynumootil; Nair, Balakrishnan; Thomas, Shaji; Somanathan, Thara; Sebastian, Paul
2009-10-01
We report a rare case of synchronous occurrence of thyroglossal duct cyst carcinoma and thyroid carcinoma and discuss its management in detail. A 59-year-old woman was clinically diagnosed to have a thyroglossal duct cyst and a solitary nodule. Fine-needle aspiration cytology revealed a papillary carcinoma in the thyroglossal duct cyst and a colloid in the thyroid nodule. Sistrunk's procedure along with a total thyroidectomy was performed followed by postoperative radioiodine ablation. Histopathologic examination revealed thyroglossal duct cyst carcinoma and bilateral foci of papillary carcinoma in the thyroid gland. She has remained free of disease on follow-up. Most cancers arising in thyroglossal duct cysts are of low risk, and Sistrunk's procedure is an adequate treatment for such cancers. However, for synchronously occurring cancers of the thyroglossal duct cyst and thyroid gland, or high-risk thyroglossal duct cyst cancers, more aggressive treatment comprising total thyroidectomy, Sistrunk's procedure, and radioiodine therapy is indicated. (c) 2009 Wiley Periodicals, Inc.
[Clinicopathologic features of drug-induced vanishing bile duct syndrome].
Ye, L H; Wang, C K; Zhang, H C; Liu, Z Q; Zheng, H W
2017-04-20
Vanishing bile duct syndrome (VBDS) manifests as progressive destruction and disappearance of the intrahepatic bile duct caused by various factors and cholestasis. VBDS associated with drug-induced liver injury (D-VBDS) is an important etiology of VBDS, and immune disorder or immune imbalance may be the main pathogenesis. According to its clinical symptoms, serological markers, and course of the disease, D-VBDS is classified into major form and minor form, and its clinical features are based on various pathomorphological findings. Its prognosis is associated various factors including regeneration of bile duct cells, number of bile duct injuries, level and range of bile duct injury, bile duct proliferation, and compensatory shunt of bile duct branches. This disease has various clinical outcomes; most patients have good prognosis after drug withdrawal, and some patients may experience cholestatic cirrhosis, liver failure, and even death. Due to the clinical manifestation and biochemical changes are similar to the primary biliary cholangitis (PBC) and primary sclerosing cholangitis (PSC), it need to identify by clinical physician.
Cystic Duct Closure by Sealing With Bipolar Electrocoagulation
Damgaard, B.; Jorgensen, L. N.; Larsen, S. S.; Kristiansen, V. B.
2010-01-01
Background: Cystic duct leakage after cholecystectomy is not uncommon and is a potentially serious complication. The aim of this study was to assess a bipolar sealing system (LigaSure®) for closure of the cystic duct. Methods: The records from consecutive laparoscopic cholecystectomies performed in 2 hospitals with closure of the cystic duct with LigaSure after informed consent were recorded and complications and morbidity registered. The records were compared with those of patients undergoing laparoscopic cholecystectomy with closure of the cystic duct with clips during the same period. Results: During the study period, 218 laparoscopic cholecystectomies were performed; 102 of these were performed with the LigaSure. One patient was excluded due to violation of the protocol. We experienced no cases of cystic duct leakage, but in one patient, bile leakage from the gallbladder bed was observed probably due to a small aberrant duct. Conclusion: The LigaSure system was safe and effective for closure and division of the cystic duct in laparoscopic cholecystectomy. PMID:20412641
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siuru, B.
1996-07-01
Large amounts of energy are wasted when heat leaks through ductwork located in uninsulated spaces. The Electric Power Research INstitute recently did a study that accurately measured these losses, then substantially reduced them by sealing the leaky ductwork. Six homes in the Pacific Northwest with significant duct leakage to the outside were selected for the study. The homes had electric resistance or heat pump, forced-air heating systems with a major portion of the supply and return ductwork in crawl spaces, attics, garages, etc. Measurements of duct leakage and heating system efficiency were done on all the homes before starting themore » duct sealing. Retrofitting included finding holes, gaps, cracks and disconnected joints in supply and return ducts as well as in plenums. When necessary, plenums were cut open for repairs. Leaks were sealed with Latex mastic and fiberglass tape. Outside ducts were covered or wrapped with insulation. Unducted returns were sealed with duct board. In some cases, leakage was corrected by merely reconnecting ducts and boots.« less
Kleeff, Jorg; Whitcomb, David C; Shimosegawa, Tooru; Esposito, Irene; Lerch, Markus M; Gress, Thomas; Mayerle, Julia; Drewes, Asbjørn Mohr; Rebours, Vinciane; Akisik, Fatih; Muñoz, J Enrique Domínguez; Neoptolemos, John P
2017-09-07
Chronic pancreatitis is defined as a pathological fibro-inflammatory syndrome of the pancreas in individuals with genetic, environmental and/or other risk factors who develop persistent pathological responses to parenchymal injury or stress. Potential causes can include toxic factors (such as alcohol or smoking), metabolic abnormalities, idiopathic mechanisms, genetics, autoimmune responses and obstructive mechanisms. The pathophysiology of chronic pancreatitis is fairly complex and includes acinar cell injury, acinar stress responses, duct dysfunction, persistent or altered inflammation, and/or neuro-immune crosstalk, but these mechanisms are not completely understood. Chronic pancreatitis is characterized by ongoing inflammation of the pancreas that results in progressive loss of the endocrine and exocrine compartment owing to atrophy and/or replacement with fibrotic tissue. Functional consequences include recurrent or constant abdominal pain, diabetes mellitus (endocrine insufficiency) and maldigestion (exocrine insufficiency). Diagnosing early-stage chronic pancreatitis is challenging as changes are subtle, ill-defined and overlap those of other disorders. Later stages are characterized by variable fibrosis and calcification of the pancreatic parenchyma; dilatation, distortion and stricturing of the pancreatic ducts; pseudocysts; intrapancreatic bile duct stricturing; narrowing of the duodenum; and superior mesenteric, portal and/or splenic vein thrombosis. Treatment options comprise medical, radiological, endoscopic and surgical interventions, but evidence-based approaches are limited. This Primer highlights the major progress that has been made in understanding the pathophysiology, presentation, prevalence and management of chronic pancreatitis and its complications.
Spatial Convergence of Three Dimensional Turbulent Flows
NASA Technical Reports Server (NTRS)
Park, Michael A.; Anderson, W. Kyle
2016-01-01
Finite-volume and finite-element schemes, both implemented within the FUN3D flow solver, are evaluated for several test cases described on the Turbulence-Modeling Resource (TMR) web site. The cases include subsonic flow over a hemisphere cylinder, subsonic flow over a swept bump configuration, and supersonic flow in a square duct. The finite- volume and finite-element schemes are both used to obtain solutions for the first two cases, whereas only the finite-volume scheme is used for the supersonic duct. For the hemisphere cylinder, finite-element solutions obtained on tetrahedral meshes are compared with finite- volume solutions on mixed-element meshes. For the swept bump, finite-volume solutions have been obtained for both hexahedral and tetrahedral meshes and are compared with finite-element solutions obtained on tetrahedral meshes. For the hemisphere cylinder and the swept bump, solutions are obtained on a series of meshes with varying grid density and comparisons are made between drag coefficients, pressure distributions, velocity profiles, and profiles of the turbulence working variable. The square duct shows small variation due to element type or the spatial accuracy of turbulence model convection. It is demonstrated that the finite-element scheme on tetrahedral meshes yields similar accuracy as the finite- volume scheme on mixed-element and hexahedral grids, and demonstrates less sensitivity to the mesh topology (biased tetrahedral grids) than the finite-volume scheme.
NASA Technical Reports Server (NTRS)
Hippensteele, Steven A.; Poinsatte, Philip E.
1993-01-01
In this transient technique the preheated isothermal model wall simulates the classic one-dimensional, semi-infinite wall heat transfer conduction problem. By knowing the temperature of the air flowing through the model, the initial temperature of the model wall, and the surface cooling rate measured at any location with time (using the fast-response liquid-crystal patterns recorded on video tape), the heat transfer coefficient can be calculated for the color isothermal pattern produced. Although the test was run transiently, the heat transfer coefficients are for the steady-state case. The upstream thermal boundary condition was considered to be isothermal. This transient liquid-crystal heat-transfer technique was used in a transient air tunnel in which a square-inlet, 3-to-1 exit transition duct was placed. The duct was preheated prior to allowing room temperature air to be suddenly drawn through it. The resulting isothermal contours on the duct surfaces were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the temperature and time data for all points on the duct surfaces during each test. The duct surfaces were uniformly heated using two heating systems: the first was an automatic temperature-controlled heater blanket completely surrounding the test duct like an oven, and the second was an internal hot-air loop through the inside of the test duct. The hot-air loop path was confined inside the test duct by insulated heat dams located at the inlet and exit ends of the test duct. A recirculating fan moved hot air into the duct inlet, through the duct, out of the duct exit, through the oven, and back to the duct inlet. The temperature nonuniformity of the test duct model wall was held very small. Test results are reported for two inlet Reynolds numbers of 200,000 and 1,150,000 (based on the square-inlet hydraulic diameter) and two free-stream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 20 percent (using a grid), which is typical of real engine conditions.
An Integration of the Turbojet and Single-Throat Ramjet
NASA Technical Reports Server (NTRS)
Trefny, C. J.; Benson, T. J.
1995-01-01
A turbine-engine-based hybrid propulsion system is described. Turbojet engines are integrated with a single-throat ramjet so as to minimize variable geometry and eliminate redundant propulsion components. The result is a simple, lightweight system that is operable from takeoff to high Mach numbers. Non-afterburning turbojets are mounted within the ramjet duct. They exhaust through a converging-diverging (C-D) nozzle into a common ramjet burner section. At low speed the ejector effect of the C-D nozzle aerodynamically isolates the relatively high pressure turbojet exhaust stream from the ramjet duct. As the Mach number increases, and the turbojet pressure ratio diminishes, the system is biased naturally toward ramjet operation. The common ramjet burner is fueled with hydrogen and thermally choked, thus avoiding the weight and complexity of a variable geometry, split-flow exhaust system. The mixed-compression supersonic inlet and subsonic diffuser are also common to both the turbojet and ramjet cycles. As the compressor face total temperature limit is approached, a two-position flap within the inlet is actuated, which closes off the turbojet inlet and provides increased internal contraction for ramjet operation. Similar actuation of the turbojet C-D nozzle flap completes the enclosure of the turbojet. Performance of the hybrid system is compared herein to that of the discrete turbojet and ramjet engines from takeoff to Mach 6. The specific impulse of the hybrid system falls below that of the non-integrated turbojet and ramjet because of ejector and Rayleigh losses. Unlike the discrete turbojet or ramjet however, the hybrid system produces thrust over the entire Mach number range. An alternate mode of operation for takeoff and low speed is also described. In this mode the C-D nozzle flap is deflected to a third position, which closes off the ramjet duct and eliminates the ejector total pressure loss.
Design of power-plant installations pressure-loss characteristics of duct components
NASA Technical Reports Server (NTRS)
Henry, John R
1944-01-01
A correlation of what are believed to be the most reliable data available on duct components of aircraft power-plant installations is presented. The information is given in a convenient form and is offered as an aid in designing duct systems and, subject to certain qualifications, as a guide in estimating their performance. The design and performance data include those for straight ducts; simple bends of square, circular, and elliptical cross sections; compound bends; diverging and converging bends; vaned bends; diffusers; branch ducts; internal inlets; and an angular placement of heat exchangers. Examples are included to illustrate methods of applying these data in analyzing duct systems. (author)
Transition duct with divided upstream and downstream portions
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier
2015-07-14
Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing themore » upstream portion and the downstream portion.« less
Repka, Michael X; Chandler, Danielle L; Holmes, Jonathan M; Hoover, Darren L; Morse, Christine L; Schloff, Susan; Silbert, David I; Tien, D Robbins
2009-05-01
To compare the outcomes of balloon catheter dilation and nasolacrimal intubation as treatment for congenital nasolacrimal duct obstruction after failed probing in children younger than 4 years. We conducted a prospective, nonrandomized, multicenter study that enrolled 159 children aged 6 months to younger than 48 months who had a history of a single failed nasolacrimal duct probing and at least 1 of the following clinical signs of nasolacrimal duct obstruction: epiphora, mucous discharge, or increased tear lake. One hundred ninety-nine eyes underwent either balloon catheter nasolacrimal duct dilation or nasolacrimal duct intubation. Treatment success was defined as absence of epiphora, mucous discharge, or increased tear lake at the outcome visit 6 months after surgery. Treatment success was reported in 65 of 84 eyes (77%; 95% confidence interval, 65%-85%) in the balloon catheter dilation group compared with 72 of 88 eyes (84% after adjustment for intereye correlation; 74%-91%) in the nasolacrimal intubation group (risk ratio for success for intubation vs balloon dilation, 1.08; 0.95-1.22). Both balloon catheter dilation and nasolacrimal duct intubation alleviate the clinical signs of persistent nasolacrimal duct obstruction in a similar percentage of patients.
LeSage, G D; Glaser, S S; Marucci, L; Benedetti, A; Phinizy, J L; Rodgers, R; Caligiuri, A; Papa, E; Tretjak, Z; Jezequel, A M; Holcomb, L A; Alpini, G
1999-05-01
Bile duct damage and/or loss is limited to a range of duct sizes in cholangiopathies. We tested the hypothesis that CCl4 damages only large ducts. CCl4 or mineral oil was given to bile duct-ligated (BDL) rats, and 1, 2, and 7 days later small and large cholangiocytes were purified and evaluated for apoptosis, proliferation, and secretion. In situ, we measured apoptosis by morphometric and TUNEL analysis and the number of small and large ducts by morphometry. Two days after CCl4 administration, we found an increased number of small ducts and reduced number of large ducts. In vitro apoptosis was observed only in large cholangiocytes, and this was accompanied by loss of proliferation and secretion in large cholangiocytes and loss of choleretic effect of secretin. Small cholangiocytes de novo express the secretin receptor gene and secretin-induced cAMP response. Consistent with damage of large ducts, we detected cytochrome P-4502E1 (which CCl4 converts to its radicals) only in large cholangiocytes. CCl4 induces selective apoptosis of large ducts associated with loss of large cholangiocyte proliferation and secretion.
Mungroop, Timothy H; van Rijssen, L Bengt; van Klaveren, David; Smits, F Jasmijn; van Woerden, Victor; Linnemann, Ralph J; de Pastena, Matteo; Klompmaker, Sjors; Marchegiani, Giovanni; Ecker, Brett L; van Dieren, Susan; Bonsing, Bert; Busch, Olivier R; van Dam, Ronald M; Erdmann, Joris; van Eijck, Casper H; Gerhards, Michael F; van Goor, Harry; van der Harst, Erwin; de Hingh, Ignace H; de Jong, Koert P; Kazemier, Geert; Luyer, Misha; Shamali, Awad; Barbaro, Salvatore; Armstrong, Thomas; Takhar, Arjun; Hamady, Zaed; Klaase, Joost; Lips, Daan J; Molenaar, I Quintus; Nieuwenhuijs, Vincent B; Rupert, Coen; van Santvoort, Hjalmar C; Scheepers, Joris J; van der Schelling, George P; Bassi, Claudio; Vollmer, Charles M; Steyerberg, Ewout W; Abu Hilal, Mohammed; Groot Koerkamp, Bas; Besselink, Marc G
2017-12-12
The aim of this study was to develop an alternative fistula risk score (a-FRS) for postoperative pancreatic fistula (POPF) after pancreatoduodenectomy, without blood loss as a predictor. Blood loss, one of the predictors of the original-FRS, was not a significant factor during 2 recent external validations. The a-FRS was developed in 2 databases: the Dutch Pancreatic Cancer Audit (18 centers) and the University Hospital Southampton NHS. Primary outcome was grade B/C POPF according to the 2005 International Study Group on Pancreatic Surgery (ISGPS) definition. The score was externally validated in 2 independent databases (University Hospital of Verona and University Hospital of Pennsylvania), using both 2005 and 2016 ISGPS definitions. The a-FRS was also compared with the original-FRS. For model design, 1924 patients were included of whom 12% developed POPF. Three predictors were strongly associated with POPF: soft pancreatic texture [odds ratio (OR) 2.58, 95% confidence interval (95% CI) 1.80-3.69], small pancreatic duct diameter (per mm increase, OR: 0.68, 95% CI: 0.61-0.76), and high body mass index (BMI) (per kg/m increase, OR: 1.07, 95% CI: 1.04-1.11). Discrimination was adequate with an area under curve (AUC) of 0.75 (95% CI: 0.71-0.78) after internal validation, and 0.78 (0.74-0.82) after external validation. The predictive capacity of a-FRS was comparable with the original-FRS, both for the 2005 definition (AUC 0.78 vs 0.75, P = 0.03), and 2016 definition (AUC 0.72 vs 0.70, P = 0.05). The a-FRS predicts POPF after pancreatoduodenectomy based on 3 easily available variables (pancreatic texture, duct diameter, BMI) without blood loss and pathology, and was successfully validated for both the 2005 and 2016 POPF definition.
Turbojet-type engines for the airbreathing propulsion of reusable winged launchers
NASA Astrophysics Data System (ADS)
Duparcq, J. L.; Hermant, E.; Scherrer, D.
Combined propulsion systems for hypersonic application have become new challenges for industrial and research organizations. In France, SNECMA and SEP, which have just joined together for a common effort on hypersonics within Hyperspace, and ONERA have been involved, under CNES (French space agency) contracts, in the assessment of new propulsion concepts for reusable winged launchers (SSTO or TSTO). As potential solutions for the airbreathing propulsion, some turbojet-type engines are presented: —the twin spool turbojet or turbofan with reheat —the turbojet with reheat —the twin-duct turbojet ramjet —the precooled turbojet with reheat. All these engines have been sized for a flight Mach number under seven with a cryogenic fuel (liquid hydrogen). Mainly due to total temperature and pressure encountered along the trajectory, the systems will have to withstand severe physical constraints. Coupled with performance and size requirements, like specific thrust and maximum air capture area, these operating conditions have been taken into account in order to select each engine cycle and technical arrangement. Performance and mass criteria make it possible to compare these systems and to emphasize their distinctive features among the propulsion concepts envisioned for the future reusable winged launchers (including airbreathing combined engines under study in France). The first step of the final selection, leading to the best adaptation between the engine and the vehicle, will then be tackled. This will be particularly enhanced by the analysis of potential advantages or technical difficulties, like thrust-to-weight ratio or needs of variable geometry and heat exchangers. The twin-duct turbojet ramjet, for example, is probably one of the best candidates for the first stages of propulsion of a reusable winged launcher.
Gebhardt, C; Riemann, J F; Lux, G
1983-03-01
In patients with haemorrhagic necrotizing pancreatitis who are scheduled for surgery, we have been carrying out a preoperative retrograde investigation of the pancreatic duct system for the past 3 months. The results in, to date, ten patients, all of whom survived their severe illness, revealed four different morphological findings of importance for the surgical tactic. 1. A normal pancreatic duct system with no signs of fistulae: only peripancreatic necrosectomy is required. 2. Contrast medium leaks via a ductal fistula: left resection, including the removal of the fistulous area, must be done. 3. Normal duct system with complete segmental parenchymal staining, representing total necrosis in this region: left resection of the pancreas. 4. Duodenoscopically demonstrable perforation into the duodenum of a necrotic cavity in the head of the pancreas: conservative management only, no surgery, since this lesions, resulting in drainage of the necrotic cavity into the bowel, permits self-healing, while the site of the perforation within the necrotic wall cannot be dealt with by surgery. The experience gained so far indicates that the surgical tactic can be determined with greater selectivity by the use of ERCP.
Development of a 32 Inch Diameter Levitated Ducted Fan Conceptual Design
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.; Gallo, Christopher a.; Solano, Paul A.; Thompson, William K.; Vrnak, Daniel R.
2006-01-01
The NASA John H. Glenn Research Center has developed a revolutionary 32 in. diameter Levitated Ducted Fan (LDF) conceptual design. The objective of this work is to develop a viable non-contact propulsion system utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels, and mitigate many of the concerns and limitations encountered in conventional aircraft propulsors. The physical layout consists of a ducted fan drum rotor with blades attached at the outer diameter and supported by a stress tuner ring at the inner diameter. The rotor is contained within a stator. This concept exploits the unique physical dimensions and large available surface area to optimize a custom, integrated, electromagnetic system that provides both the levitation and propulsion functions. The rotor is driven by modulated electromagnetic fields between the rotor and the stator. When set in motion, the time varying magnetic fields interact with passive coils in the stator assembly to produce repulsive forces between the stator and the rotor providing magnetic suspension. LDF can provide significant improvements in aviation efficiency, reliability, and safety, and has potential application in ultra-efficient motors, computers, and space power systems.
NASA Technical Reports Server (NTRS)
Davis, David O.
1991-01-01
Steady, incompressible, turbulent, swirl-free flow through a circular-to-rectangular transition duck was studied experimentally. The cross-sectional area remains the same at the exit as at the inlet, but varies through the transition section to a maximum value approximately 15 percent above the inlet value. The cross-sectional geometry everywhere along the duct is defined by the equation of a superellipse. Mean and turbulence data were accumulated utilizing pressure and hot-wire instrumentation at five stations along the test section. Data are presented for operating bulk Reynolds numbers of 88,000 and 390,000. Measured quantities include total and static pressure, the three components of the mean velocity vector, and the six components of the Reynolds stress tensor. In addition to the transition duct measurements, a hot-wire technique which relies on the sequential use of single rotatable normal and slant-wire probes was proposed. The technique is applicable for measurement of the total mean velocity vector and the complete Reynolds stress tensor when the primary flow is arbitrarily skewed relative to a plane which lies normal to the probe axis of rotation.
Pancreatic acinar cell carcinoma extending into the common bile and main pancreatic ducts.
Yamaguchi, Rin; Okabe, Yoshinobu; Jimi, Atsuo; Shiota, Koji; Kodama, Takahito; Naito, Yoshiki; Yasunaga, Masafumi; Kinoshita, Hisafumi; Kojiro, Masamichi
2006-10-01
Acinar cell carcinoma (ACC) of the pancreas is relatively rare, accounting for only approximately 1% of all exocrine pancreatic tumors. A 69-year-old man was found to have a mass lesion measuring approximately 4 cm in diameter in the pancreatic head on ultrasound, abdominal dynamic CT, and percutaneous transhepatic cholangiography. Magnetic resonance cholangiopancreatography showed defect of the lower common bile duct (CBD) due to obstruction by the tumor cast. Histopathologically, the pancreatic head tumor invaded the main pancreatic duct (MPD) and CBD with extension into the CBD in a form of tumor cast. The tumor cells consisted of a solid proliferation with abundant eosinophilic cytoplasm and round nuclei in an acinar and trabecular fashion. A 55-year-old man with upper abdominal pain and nausea, had a cystic lesion approximately 3 cm in size in the pancreatic tail on CT. Histopathologically, the tumor was encapsulated by fibrous capsule and had extensive central necrosis with solid areas in the tumor periphery, and invaded with extension into the MPD in a form of tumor cast. The tumor cells resembled acinar cells in solid growths. Two resected cases of ACC with unusual tumor extension into the CBD and the MPD, respectively, are reported.
Flow Simulation of Supersonic Inlet with Bypass Annular Duct
NASA Technical Reports Server (NTRS)
Kim, HyoungJin; Kumano, Takayasu; Liou, Meng-Sing; Povinelli, Louis A.; Conners, Timothy R.
2011-01-01
A relaxed isentropic compression supersonic inlet is a new concept that produces smaller cowl drag than a conventional inlet, but incurs lower total pressure recovery and increased flow distortion in the (radially) outer flowpath. A supersonic inlet comprising a bypass annulus to the relaxed isentropic compression inlet dumps out airflow of low quality through the bypass duct. A reliable computational fluid dynamics solution can provide considerable useful information to ascertain quantitatively relative merits of the concept, and further provide a basis for optimizing the design. For a fast and reliable performance evaluation of the inlet performance, an equivalent axisymmetric model whose area changes accounts for geometric and physical (blockage) effects resulting from the original complex three-dimensional configuration is proposed. In addition, full three-dimensional calculations are conducted for studying flow phenomena and verifying the validity of the equivalent model. The inlet-engine coupling is carried out by embedding numerical propulsion system simulation engine data into the flow solver for interactive boundary conditions at the engine fan face and exhaust plane. It was found that the blockage resulting from complex three-dimensional geometries in the bypass duct causes significant degradation of inlet performance by pushing the terminal normal shock upstream.
Bioregenerative system components for microgravity
NASA Technical Reports Server (NTRS)
Nevill, Gale E., Jr.; Hessel, Michael I., Jr.
1992-01-01
The goal of the class was to design, fabricate, and test prototype designs that were independent, yet applicable to a Closed Loop Life Support System. The three prototypes chosen were in the areas of agar plant growth, regnerative filtration, and microgravity food preparation. The plant growth group designed a prototype agar medium growth system that incorporates nutrient solution replenishment and post-harvest refurbishment. In addition, the unit emphasizes material containment and minimization of open interfaces. The second project was a filter used in microgravity that has the capability to clean itself. The filters are perforated plates which slide through a duct and are cleaned outside of the flow with a vacuum system. The air in the duct is prevented from flowing outside of the duct by a network of sliding seals. The food preparation group developed a device which dispenses and mixes ingredients and then cooks the mixture in microgravity. The dry ingredients are dispensed from a canister by a ratchet-operated piston. The wet ingredients are dispensed from plastic bags through tubing attached to a syringe. Once inside the mixing chamber, the ingredients are mixed using a collapsible whisk and then pushed into the cooking device.
Zoepf, Thomas; Maldonado-Lopez, Evelyn J; Hilgard, Philip; Schlaak, Joerg; Malago, Massimo; Broelsch, Christoph E; Treichel, Ulrich; Gerken, Guido
2005-11-01
Endoscopic treatment of biliary strictures after liver transplantation is a therapeutic challenge. In particular, outcomes of endoscopic therapy of biliary complications in the case of duct-to-duct anastomosis after living related liver transplantation are limited. The aim of this study was to evaluate the feasibility and success of an endoscopic treatment approach to posttransplant biliary strictures (PTBS) after right-sided living donor liver transplantation (RLDLT) with duct-to-duct anastomosis. Ninety patients who received adult-to-adult RLDLT in our center were screened retrospectively with respect to endoscopic treatment of PTBS. Therapy was judged as successful when cholestasis parameters returned to normal and bile duct narrowing was reduced significantly after the completion of therapy. Forty of 90 RLDLT patients received duct-to-duct anastomosis, 12 (30%) showed PTBS. Seven of 12 patients were treated successfully by endoscopy; the remaining 5 patients were treated primarily by surgery. Most patients were treated by balloon dilatation followed by insertion of endoprostheses. A median of 2.5 dilatation sessions were necessary and the median treatment duration was 8 months. One patient developed endoscopy-treatable recurrent stenosis, no surgical intervention was necessary. Mild pancreatitis occurred in 7.9% and cholangitis in 5.3% of the procedures. One minor bleeding episode occurred during sphincterotomy. Bleeding was managed endoscopically. Endoscopic therapy of adult-to-adult right living related liver transplantation with duct-to-duct anastomosis is feasible and frequently is successful. The duct-to-duct anastomosis offers the possibility of endoscopic treatment. Endoscopic treatment of posttransplant biliary strictures is safe, with a low specific complication rate.
Albumin expression distinguishes bile duct adenomas from metastatic adenocarcinoma.
Moy, Andrea P; Arora, Kshitij; Deshpande, Vikram
2016-09-01
Bile duct adenomas may be difficult to distinguish from metastatic carcinomas, particularly well-differentiated pancreatic ductal adenocarcinoma. Prior studies have evaluated the utility of various immunohistochemical markers, although these markers are notable for low sensitivity and/or specificity. The aim of this study was to investigate the utility of albumin and BRAFV600E expression in distinguishing between metastatic pancreatic adenocarcinoma and bile duct adenoma. We studied 26 bile duct adenomas, three bile duct hamartomas, and 158 pancreatic ductal adenocarcinomas. Branched-chain in-situ hybridization (bISH) for albumin was performed; bISH is based on the branched DNA technology, wherein signal amplification is achieved via a series of sequential steps. Additionally, BRAFV600E immunohistochemistry (IHC) was performed on a subset of cases. Twenty-three of 25 (92%) bile duct adenomas were positive for albumin; 18 (72%) showed diffuse staining, and five showed focal staining (20%), including two challenging examples. Two bile duct hamartomas also stained positively. All pancreatic adenocarcinomas were negative for albumin. Seven of 16 (44%) bile duct adenomas and five of 106 (5%) pancreatic ductal adenocarcinomas were positive for BRAFV600E by IHC. The sensitivity and specificity of expression of albumin, as detected by bISH, for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 92% and 100%, respectively; the sensitivity and specificity of BRAFV600E IHC for distinguishing bile duct adenomas from metastatic pancreatic adenocarcinomas were 43.8% and 95.3%, respectively. Diagnostically challenging examples of bile duct adenoma may be distinguished from metastatic pancreatic adenocarcinoma by the use of albumin bISH. © 2016 John Wiley & Sons Ltd.
Sasaki, Maho; Hori, Tomohide; Furuyama, Hiroaki; Machimoto, Takafumi; Hata, Toshiyuki; Kadokawa, Yoshio; Ito, Tatsuo; Kato, Shigeru; Yasukawa, Daiki; Aisu, Yuki; Kimura, Yusuke; Takamatsu, Yuichi; Kitano, Taku; Yoshimura, Tsunehiro
2017-08-08
BACKGROUND Postoperative bile duct leak following hepatobiliary and pancreatic surgery can be intractable, and the postoperative course can be prolonged. However, if the site of the leak is in the distal bile duct in the main biliary tract, the therapeutic options may be limited. Injection of absolute ethanol into the bile duct requires correct identification of the bile duct, and balloon occlusion is useful to avoid damage to the surrounding tissues, even in cases with non-communicating biliary fistula and bile leak. CASE REPORT Two cases of non-communicating biliary fistula and bile leak are presented; one case following pancreaticoduodenectomy (Whipple's procedure), and one case following laparoscopic cholecystectomy. Both cases were successfully managed by chemical bile duct ablation with absolute ethanol. In the first case, the biliary leak occurred from a fistula of the right posterior biliary tract following pancreaticoduodenectomy. Cannulation of the leaking bile duct and balloon occlusion were achieved via a percutaneous route, and seven ablation sessions using absolute ethanol were required. In the second case, perforation of the bile duct branch draining hepatic segment V occurred following laparoscopic cholecystectomy. Cannulation of the bile duct and balloon occlusion were achieved via a transhepatic route, and seven ablation sessions using absolute ethanol were required. CONCLUSIONS Chemical ablation of the bile duct using absolute ethanol is an effective treatment for biliary leak following hepatobiliary and pancreatic surgery, even in cases with non-communicating biliary fistula. Identification of the bile duct leak is required before ethanol injection to avoid damage to the surrounding tissues.
Biliary and pancreatic ductal dilation in patients on methadone maintenance therapy.
Bates, David D B; Tamayo-Murillo, Dorathy; Kussman, Steven; Luce, Adam; LeBedis, Christina A; Soto, Jorge A; Anderson, Stephan W
2017-03-01
To determine whether the diameter of intrahepatic and extrahepatic bile ducts and pancreatic ducts in patients on methadone maintenance therapy is increased when compared with control subjects. Between January 1, 2000 and March 15, 2013, a total of 97 patients (mean age 49.9, range 22-79, 65 male, 32 female) were identified who were receiving chronic methadone maintenance therapy (MMT) when they underwent imaging with abdominal MRI or a contrast-enhanced abdominopelvic CT. A group of 97 consecutive non-MMT control patients (mean age 51.4, range 21-86, 45 male, 52 female) who underwent imaging with abdominal MRI or contrast-enhanced abdominopelvic CT were identified. Patients with known pancreaticobiliary pathology that may confound biliary ductal measurements were excluded. Blinded interpretation was performed, documenting the diameters of the intrahepatic and extrahepatic bile ducts and pancreatic ducts. Descriptive statistics were performed. Patients on MMT demonstrated increased bile duct diameter, with an average increase in duct diameter of 2.39 mm for the common bile duct (p < 0.001; 95% CI 1.88-2.90 mm), 1.43 mm for the intrahepatic bile ducts (p < 0.001; 95% CI 1.12-1.74 mm), and 0.90 mm for the pancreatic duct (p < 0.001; 95% CI 0.64-1.16 mm). No statistically significant correlation was found between ductal diameters and the daily dose of methadone. Patients on methadone maintenance therapy demonstrate significantly increased intra- and extrahepatic bile duct and pancreatic duct diameter when compared with controls. There was no correlation between the dose of methadone and ductal diameter.
Performance Analysis of a Modular Small-Diamter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Rudd, Armin
2016-03-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
Assadourian, R; Chometowski, S; Bourde, J; Poitout, D; Lamy, J
1975-10-01
The association of perforation of the common bile duct, cholecystitis and acute pancreatitis, should be emphasized. Physiopathology of perforation of the bile duct may be compared with that of pancreatitis. Repair of the bile duct may be delicate requiring hepatico-jejunostomy on an isolated loop.
Experiments on H2-O2MHD power generation
NASA Technical Reports Server (NTRS)
Smith, J. M.
1980-01-01
Magnetohydrodynamic power generation experiments utilizing a cesium-seeded H2-O2 working fluid were carried out using a diverging area Hall duct having an entrance Mach number of 2. The experiments were conducted in a high-field strength cryomagnet facility at field strengths up to 5 tesla. The effects of power takeoff location, axial duct location within the magnetic field, generator loading, B-field strength, and electrode breakdown voltage were investigated. For the operating conditions of these experiments, it is found that the power output increases with the square of the B-field and can be limited by choking of the channel or interelectrode voltage breakdown which occurs at Hall fields greater than 50 volts/insulator. Peak power densities of greater than 100 MW/cu M were achieved.
Development of laminar flow control wing surface porous structure
NASA Technical Reports Server (NTRS)
Klotzsche, M.; Pearce, W.; Anderson, C.; Thelander, J.; Boronow, W.; Gallimore, F.; Brown, W.; Matsuo, T.; Christensen, J.; Primavera, G.
1984-01-01
It was concluded that the chordwise air collection method, which actually combines chordwise and spanwise air collection, is the best of the designs conceived up to this time for full chord laminar flow control (LFC). Its shallower ducting improved structural efficiency of the main wing box resulting in a reduction in wing weight, and it provided continuous support of the chordwise panel joints, better matching of suction and clearing airflow requirements, and simplified duct to suction source minifolding. Laminar flow control on both the upper and lower surfaces was previously reduced to LFC suction on the upper surface only, back to 85 percent chord. The study concludes that, in addition to reduced wing area and other practical advantages, this system would be lighter because of the increase in effective structural wing thickness.
STS-56 inflight maintenance (IFM) air duct routing on OV-103's middeck
NASA Technical Reports Server (NTRS)
1993-01-01
STS-56 inflight maintenance (IFM) repair on Discovery's, Orbiter Vehicle (OV) 103's, middeck was required to offset overheating problems with one of the onboard experiments -- Detailed Supplementary Objective (DSO) 322, Human lymphocyte locomotion in microgravity. This 'elephant's trunk' fix was rigged from the airlock's air recirculation duct to DSO 322's forward locker location by Commander Kenneth Cameron. The 'elephant's trunk' was fashioned from trash bags and other plastic items to extend an airline to the troubled area. DSO 322 is collecting data on the locomotion and migration of human lymphocytes through intercellular matrix and is testing the rotating wall vessel and the specimen temperature controller. In the background is the port side wall with the side hatch, middeck accomodations rack (MAR), and shuttle orbiter repackaged galley (SORG) visible.
Three-dimensional vasculature of the bovine liver.
Shirai, W; Sato, T; Shibuya, H; Naito, K; Tsukise, A
2005-12-01
To clarify anatomical distribution of Fasciola infection, the vascular and ductal architectures of the liver were studied by means of corrosion cast technique using synthetic resin. The arteria hepatica propria (AP) passes as the arteria gastroduodenalis (AG); AP becomes the left trunk after the porta hepatis; AP passes on the right side of vena porta communis (VPC) and projects AG while curving in a U-shape below the portal vein. Hepatic veins located between the vena hepatica media (HM) and vena hepatica dextra (HD) varied widely among specimens and were irregular, including the vena hepatica dorso-lateralis sinistra (Hds), vena hepatica dorso-lateralis dextra (Hdd), vena hepatica lobi caudati (Hlc), venae hepaticae processus caudati (Hpc), venae hepaticae processus papillaris (Hpp), and the hepatic vein to the dorsal intermediate part, which directly or indirectly drained into the vena cava caudalis. The courses of the bovine hepatic veins were markedly diverse, and anastomoses between vena hepatica sinistra (HS) and Hds were observed in about a half of the livers. The portal vein entered the liver as VPC slightly above the centre of the right lobe on the visceral surface. The intermediate or transverse part [pars transversa trunci sinistri (PTS)] of truncus sinister (TS), which extends from the entry of the portal vein into the left lobe of the liver, was slightly arched downward [pars umbilicalis trunci sinistri (PUS)]. The portal vein further arched from the distal end of TS to the umbilical vein and ran towards the inter-lobar incision between the left lobe and quadrate lobe. Based on these branches, hepatic segments were determined as 13 or 14 areas. A total of 15 bile ducts were derived from various lobes. The hepatic duct was about 2.6-6 cm long from the confluence of the right and left hepatic ducts to the division of the cystic duct and the common hepatic duct.
Effects of rising angle on upstream blades and intermediate turbine duct
NASA Astrophysics Data System (ADS)
Liu, Jun; Wang, Pei; Du, Qiang; Liu, Guang; Zhu, Junqiang
2016-08-01
With the improvement of requirement, design and manufacture technology, aero-engines for the future are characterized by further reduction in fuel consumption, cost, but increment in propulsion efficiency, which leads to ultra-high bypass ratio. The intermediate turbine duct (ITD), which connects the high pressure turbine (HPT) with the low pressure turbine (LPT), has a critical impact on the overall performances of such future engines. Therefore, it becomes more and more urgent to master the design technique of aggressive, even super-aggressive ITDs. Over the last years, a lot of research works about the flow mechanism in the diffuser ducts were carried out. Many achievements were reported, but further investigation should be performed. With the aid of numerical method, this paper focuses on the change of performance and flow field of ITD, as well as nearby turbines, brought by rising angle (RA). Eight ITDs with the same area ratio and length, but different RAs ranges from 8 degrees to 45 degrees, are compared. According to the investigation, flow field, especially outlet Ma of swirl blade is influenced by RA under potential effect, which is advisable for designers to modify HPT rotor blades after changing ITD. In addition to that, low velocity area moves towards upstream until the first bend as RA increases, while pressure loss distribution at S2 stream surface shows that hub boundary layer is more sensitive to RA, and casing layer keeps almost constant. On the other hand, the overall total pressure loss could keep nearly equivalent among different RA cases, which implies the importance of optimization.
Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.
Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru
2015-01-01
A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.
Valtolina, Chiara; Robben, Joris H; Favier, Robert P; Rothuizen, Jan; Grinwis, Guy Cm; Schotanus, Baukje A; Penning, Louis C
2018-05-01
Objectives The aim of this study was to describe the cellular and stromal components of the hepatic progenitor cell niche in feline hepatic lipidosis (FHL). Methods Immunohistochemical staining for the progenitor/bile duct marker (K19), activated Kupffer cells (MAC387), myofibroblasts (alpha-smooth muscle actin [α-SMA]) and the extracellular matrix component laminin were used on seven liver biopsies of cats with FHL and three healthy cats. Double immunofluorescence stainings were performed to investigate co-localisation of different cell types in the hepatic progenitor cell (HPC) niche. Results HPCs, Kupffer cells, myofibroblasts and laminin deposition were observed in the liver samples of FHL, although with variability in the expression and positivity of the different immunostainings between different samples. When compared with the unaffected cats where K19 positivity and minimal α-SMA and laminin positivity were seen mainly in the portal area, in the majority of FHL samples K19 and α-SMA-positive cells and laminin positivity were seen also in the periportal and parenchymatous area. MAC387-positive cells were present throughout the parenchyma. Conclusions and relevance This is a preliminary morphological study to describe the activation and co-localisation of components of the HPC niche in FHL. Although the HPC niche in FHL resembles that described in hepatopathies in dogs and in feline lymphocytic cholangitis, the expression of K19, α-SMA, MAC387 and lamin is more variable in FHL, and a common pattern of activation could not be established. Nevertheless, when HPCs were activated, a spatial association between HPCs and their niche could be demonstrated.
Laser velocimeter and total pressure measurements in circular-to-rectangular transition ducts
NASA Technical Reports Server (NTRS)
Patrick, William P.; Mccormick, Duane C.
1988-01-01
A comprehensive set of total pressure and three-component laser velocimetry (LV) data were obtained within two circular-to-rectangular transition ducts at low subsonic speeds. This set of reference data was acquired for use in identifying secondary flow mechanisms and for assessing the accuracy of computational procedures for calculating such flows. Data were obtained at the inlet and exit planes of an aspect ratio three duct having a length-to-diameter ratio of one (AR310) and an aspect ratio six duct having a length-to-diameter ratio of three (AR630). Each duct was unseparated throughout its transition section. It is therefore concluded that secondary flows can play an important part in the fluid dynamics of transition ducts and needs to be addressed in computational analysis. The strength of the secondary flows depends on both the aspect ratio and relative axial duct length.
2017-06-13
Adenocarcinoma of the Extrahepatic Bile Duct; Adenocarcinoma of the Gallbladder; Advanced Adult Primary Liver Cancer; Gastrointestinal Cancer; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer
Erlotinib in Treating Patients With Unresectable Liver, Bile Duct, or Gallbladder Cancer
2013-06-03
Adult Primary Cholangiocellular Carcinoma; Adult Primary Hepatocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer
Kulyapina, Alena; Ochandiano-Caicoya, Santiago; Navarro-Cuellar, Carlos; Navarro-Vila, Carlos
2014-01-01
Introduction: The lesions of the salivary ducts may be idiopathic, post- traumatic, or iatrogenic and lead to sialocele formation with persistent painful facial swelling or cutaneous fistula formation. No consensus on treatment of this condition exists: the options of treatment include needle aspiration, pressure dressings, antisialogogue therapy, radiotherapy, botulinum toxin and surgical approaches as duct repair, diversion, ligation, different drainage systems and even parotidectomy/submaxilectomy. The management and special features of iatrogenic salivary duct injury in patients with oral cancer who underwent head and neck reconstructive surgery has not been described yet. Material and Methods: We present four cases of iatrogenic lesions of salivary ducts and its management in patients with oral cancer. Conclusions: The iatrogenic lesions of salivary ducts are to be taken into account in patients with oral cancer as the distal ends of salivary ducts could be involved in the margins of surgical resection. Different options of treatment of this complication are described. Key words:Sialocele, oral cancer, salivary duct. PMID:25136433
Developing flow in S-shaped ducts. 2: Circular cross-section duct
NASA Technical Reports Server (NTRS)
Taylor, A. M. K. P.; Whitelaw, J. H.; Yianneskis, M.
1984-01-01
Laser-Doppler velocimetry measured the laminar and turbulent streamwise flow in a S-duct. The wall pressure distribution and one component of cross-stream velocity were also obtained for the turbulent flow case. Boundary layers near the duct inlet were about 25 percent of the hydraulic diameter in the laminar flow and varied around the periphery of the pipe between 10 percent and 20 percent in turbulent flow. Pressure-driven secondary flows develop in the first half of the S-duct and are attenuated and reversed in the second half. For both Reynolds numbers there is a region near the outer wall of the second half of the duct where the sign of the radial vorticity results in an enforcement of the secondary flow which was established in the first half of the S-duct. The core flow migrates, for both Reynolds numbers, to the outside wall of the first half and lies towards the inside wall of the second half of the S-duct at the outlet. The thinner inlet boundary layers in the turbulent flow give rise to weaker secondary motion.
Bile duct anastomotic stricture after pediatric living donor liver transplantation.
Chok, Kenneth S H; Chan, See Ching; Chan, Kwong Leung; Sharr, William W; Tam, Paul K H; Fan, Sheung Tat; Lo, Chung Mau
2012-07-01
Hepaticojejunostomy is a well-accepted method, whereas duct-to-duct anastomosis is gaining popularity for bile duct reconstruction in pediatric living donor liver transplantation (LDLT). Biliary complications, especially biliary anastomotic stricture (BAS), are not clearly defined. The aim of the present study is to determine the rate of BAS and its associated risk factors. The study included 78 pediatric patients (<18 years old) who underwent LDLT during the period from end of September 1993 to end of November 2010. The diagnosis of BAS was based on clinical, biochemical, histologic, and radiologic results. All patients received left-side grafts. Thirteen patients (16.7%) developed BAS after LDLT. Among them, 3 patients (23.1%) had duct-to-duct anastomosis during LDLT. The median follow-up period for the BAS group and the non-BAS group was 57.8 and 79.5 months, respectively (P = .683). Ten of the patients with BAS required percutaneous transhepatic biliary drainage with or without dilatation for treating the stricture. Multivariable analysis showed that hepatic artery thrombosis and duct-to-duct anastomosis were 2 risk factors associated with BAS. In pediatric LDLT, hepaticojejunostomy is the preferred method for bile duct reconstruction, but more large-scale research needs to be done to reconfirm this result. Copyright © 2012 Elsevier Inc. All rights reserved.
Common Bile Duct Stricture After Laparoscopic Cholecystectomy: Case Report
Zoričić, Ivan; Soldo, Ivo; Simović, Ivan; Sever, Marko; Bakula, Branko; Grbavac, Martin; Marušić, Marinko; Soldo, Anamaria
2017-03-01
Despite progress in laparoscopic surgery and increasing surgical experience, the incidence of bile duct injury during laparoscopic cholecystectomy fails to fall below 0.3%-0.6% and it is still higher than those recorded in the era of open cholecystectomy. Bile duct injuries belong to the most serious complications of abdominal surgery in general and often end up with liver transplantation as the only hope for cure. We present a case of a 78-year-old jaundiced male patient who sustained common hepatic duct injury during laparoscopic cholecystectomy eight months earlier. Exploratory laparotomy, ERCP and MRCP revealed a metal clip placed just below hepatic duct confluence and causing stricture of bile duct with dilatation of bile ducts proximal to the level of stenosis (Strasberg classification type E3 injury). Repair of the injury was performed by creating termino-lateral hepaticojejunostomy between the right and left hepatic ducts and retrocolic Roux en-Y jejunal limb. By presenting this case, we wish to emphasize the importance of timely conversion and execution of intraoperative cholangiography in all cases when identification of the structures of Calot’s triangle is not clear enough. Successful treatment of bile duct injury is only possible with joint approach of radiologist, gastroenterologist and experienced hepatobiliary surgeon.
Investigation of the interference effects of mixed flow long duct nacelles on a DC-10 wing
NASA Technical Reports Server (NTRS)
Patel, S. P.; Donelson, J. E.
1982-01-01
Wind tunnel test results utilizing a 4.7 percent scale semispan model in the 11 foot transonic wind tunnel are presented. A low drag long duct nacelle installation for the DC-10 jet transport was developed. A long duct nacelle representative of a CF6-50 mixed flow configuration was investigated on the DC-10-30. The results showed that the long duct nacelle installation located in the same position as the current short duct nacelle and with the current production symmetrical pylon is a relatively low risk installation for the DC-10 aircraft. Tuft observations and analytical boundary layer analysis confirmed that the flow on the nacelle afterbody was attached. A small pylon fairing was evaluated and found to reduce channel peak suction pressures, which resulted in a small drag improvement. The test also confirmed that the optimum nacelle incidence angle is the same as for the short duct nacelle, thus the same engine mount as for the production short duct nacelle can be used for the long duct nacelle installation. Comparison of the inboard wing pylon nacelle channel pressure distributions, with flow through and powered long duct nacelles showed that the power effects did not change the flow mechanism; hence, power effects can be considered negligible.
Long duct nacelle aerodynamic development for DC-10 derivatives
NASA Technical Reports Server (NTRS)
Patel, S. P.; Donelson, J. E.
1980-01-01
The results are presented of a wind tunnel test utilizing a 4.7-percent-scale semispan model of the DC-10 in the Calspan 8-foot transonic wind tunnel. The effect of a revised long-duct nacelle shape on the channel velocities, the incremental drag relative to the baseline long-duct nacelle, and channel velocities for the baseline long-duct nacelle were determined and compared with data obtained at Ames. The baseline and the revised long-duct nacelles are representative of a CF6-50 mixed-flow configuration and were evaluated on a model of a proposed DC-10 stretched-fuselage configuration. The results showed that the revised long-duct nacelle has an appreciable effect on the inboard channel velocities, resulting in an increased channel Mach number. However, the pressure recovery on the nacelle afterbody was about the same for both nacelles. The lift curves for both long-duct nacelle configurations were the same. The channel pressures measured at Calspan were in good agreement with those measured at Ames for the baseline long-duct nacelle. The incremental drag for the revised nacelle was measured as two to four counts (three counts is approximately equal to one percent of the airplane drag) higher than that of the baseline long-duct nacelle.
Viscous flow computations for elliptical two-duct version of the SSME hot gas manifold
NASA Technical Reports Server (NTRS)
Roger, R. P.
1986-01-01
The objective of the effort was to numerically simulate viscous subsonic flow in a proposed elliptical two-duct version of the fuel side Hot Gas Manifold (HGM) for the Space Shuttle Main Engine (SSME). The numerical results were to complement both water flow and air flow experiments in the two-duct geometry performed at NASA-MSFC and Rocketdyne. The three-dimensional character of the HGM consists of two essentially different geometries. The first part of the construction is a concentric shell duct structure which channels the gases from a turbine exit into the second part comprised of two cylindrically shaped transfer ducts. The initial concentric shell portion can be further subdivided into a turnaround section and a bowl section. The turnaround duct (TAD) changes the direction of the mean flow by 180 degress from a smaller radius to a larger radius duct which discharges into the bowl. The cylindrical transfer ducts are attached to the bowl on one side thus providing a plane of symmetry midway between the two. Centerline flow distance from the TAD inlet to the transfer duct exit is approximately two feet. Details of the approach used to numerically simulate laminar or turbulent flow in the HGM geometry are presented. Computational results are presented and discussed.
Koizumi, Yohei; Hirooka, Masashi; Ochi, Hironori; Tokumoto, Yoshio; Takechi, Megumi; Hiraoka, Atsushi; Ikeda, Yoshio; Kumagi, Teru; Matsuura, Bunzo; Abe, Masanori; Hiasa, Yoichi
2015-04-01
This study aimed at prospectively evaluating bile duct anatomy on ultrasonography and evaluating the safety and utility of radiofrequency ablation (RFA) assisted by virtual ultrasonography from gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI). The institutional review board approved this study, and patients provided written informed consent prior to entry into the study. Bile duct anatomy was assessed in 201 patients who underwent Gd-EOB-DTPA-enhanced MRI for the evaluation of hepatic tumor. Eighty-one of these patients subsequently underwent RFA assisted by ultrasound imaging. In 23 patients, the tumor was located within 5 mm of the central bile duct, as demonstrated by MRI. Virtual ultrasonography constructed by Gd-EOB-enhanced MRI was able to visualize the common bile duct, left hepatic duct, and right hepatic duct in 96.5, 94.0, and 89.6 % of cases, respectively. The target hepatic tumor nodule and biliary duct could be detected with virtual ultrasonography in all patients, and no severe complications occurred. The running pattern of the bile ducts could be recognized on conventional ultrasound by referencing virtual ultrasonography constructed by Gd-EOB-DTPA-enhanced MRI. RFA assisted by this imaging strategy did not result in bile duct injury.
49 CFR 176.205 - Under deck stowage requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be equipped with an overhead water sprinkler system or fixed fire extinguishing system. (3) Each... rents, tears, and holes. (7) A fire screen must be fitted at the weather end of each vent duct leading from the hold or compartment. The fire screen must completely cover the open area. It must consist of...
49 CFR 176.205 - Under deck stowage requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be equipped with an overhead water sprinkler system or fixed fire extinguishing system. (3) Each... rents, tears, and holes. (7) A fire screen must be fitted at the weather end of each vent duct leading from the hold or compartment. The fire screen must completely cover the open area. It must consist of...
49 CFR 176.205 - Under deck stowage requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... be equipped with an overhead water sprinkler system or fixed fire extinguishing system. (3) Each... rents, tears, and holes. (7) A fire screen must be fitted at the weather end of each vent duct leading from the hold or compartment. The fire screen must completely cover the open area. It must consist of...
49 CFR 176.205 - Under deck stowage requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... be equipped with an overhead water sprinkler system or fixed fire extinguishing system. (3) Each... rents, tears, and holes. (7) A fire screen must be fitted at the weather end of each vent duct leading from the hold or compartment. The fire screen must completely cover the open area. It must consist of...
NASA Astrophysics Data System (ADS)
Yu, Zhitao; Miller, Franklin; Pfotenhauer, John M.
2017-12-01
Both a numerical and analytical model of the heat and mass transfer processes in a CO2, N2 mixture gas de-sublimating cross-flow finned duct heat exchanger system is developed to predict the heat transferred from a mixture gas to liquid nitrogen and the de-sublimating rate of CO2 in the mixture gas. The mixture gas outlet temperature, liquid nitrogen outlet temperature, CO2 mole fraction, temperature distribution and de-sublimating rate of CO2 through the whole heat exchanger was computed using both the numerical and analytic model. The numerical model is built using EES [1] (engineering equation solver). According to the simulation, a cross-flow finned duct heat exchanger can be designed and fabricated to validate the models. The performance of the heat exchanger is evaluated as functions of dimensionless variables, such as the ratio of the mass flow rate of liquid nitrogen to the mass flow rate of inlet flue gas.
CTBT infrasound network performance to detect the 2013 Russian fireball event
Pilger, Christoph; Ceranna, Lars; Ross, J. Ole; ...
2015-03-18
The explosive fragmentation of the 2013 Chelyabinsk meteorite generated a large airburst with an equivalent yield of 500 kT TNT. It is the most energetic event recorded by the infrasound component of the Comprehensive Nuclear-Test-Ban Treaty-International Monitoring System (CTBT-IMS), globally detected by 20 out of 42 operational stations. This study performs a station-by-station estimation of the IMS detection capability to explain infrasound detections and nondetections from short to long distances, using the Chelyabinsk meteorite as global reference event. Investigated parameters influencing the detection capability are the directivity of the line source signal, the ducting of acoustic energy, and the individualmore » noise conditions at each station. Findings include a clear detection preference for stations perpendicular to the meteorite trajectory, even over large distances. Only a weak influence of stratospheric ducting is observed for this low-frequency case. As a result, a strong dependence on the diurnal variability of background noise levels at each station is observed, favoring nocturnal detections.« less
NASA Astrophysics Data System (ADS)
Oweis, Ghanem; Steven, Ceccio
2003-11-01
PIV data of the flow field in the immediate vicinity of the trailing edge of a ducted propeller at the tip revealed the existence of multiple vorticity concentrations. The multiple vortices in each instantaneous PIV field were identified and individually characterized. The measurements of the multiple vortices were combined with a Gaussian vortex model to reconstruct the vorticity and velocity fields. The major features of the original experimental field were recovered, and the correlation between the two fields was good. The time averaged field and velocity fluctuations were also measured. We will discuss why the "typical" instantaneous tip vortex and the tip vortex from the time averaged field are substantially different. We attempt to explain the cause of these differences. Knowledge of the instantaneous flow field variability is used to understand the causes of the measured velocity fluctuations. The results from this study have an impact on the understanding of the roll-up of tip vortices, and the dynamics of multiple vortices.
The statistical evaluation of duct tape end match as physical evidence
NASA Astrophysics Data System (ADS)
Chan, Ka Lok
Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.
Rangel, Ana Lúcia Carrinho Ayrosa; León, Jorge Esquiche; Jorge, Jacks; Lopes, Márcio Ajudarte; Vargas, Pablo Agustín
2008-03-01
Oncocytic metaplasia (OM) is not a well-known feature in inflammatory fibrous hyperplasia (IFH) lesions, although it may be common, as proposed in our previous study about this lesion. In the present paper, we assessed the histopathological and immunohistochemical features of 18 cases of IFH containing OM areas. All the samples were examined on haematoxylin and eosin stained sections and cytokeratins (AE1/AE3, 34betaE12, CK5, CK7, CK8, CK13, CK14 and CK19), CD15, CD20, CD68, CD45Ro, and LCA primary antibodies were used. The vast majority of IFH occurred in women (n=14) and the most common site of presentation was the buccal vestibule. Oncocytic and salivary duct cells showed uniform immunoreactivity for AE1/AE3, CK7, CK8 and CK19. CD45Ro+ T-lymphocytes were the most common inflammatory cells surrounding the OM areas followed by CD20+ B-lymphocytes. These findings suggest that oncocytic cells present in IFH might develop from salivary duct epithelium, and T-lymphocytes might play an important role in its etiopathogenesis.
Biliary Fasciola gigantica infestation in a nonendemic area--An intraoperative surprise.
Menon, Prema; Sinha, Amit Kumar; Rao, Katragadda Lakshmi Narasimha; Khurana, Sumeeta; Lal, Sadhana; Thapa, Babu Ram
2015-11-01
A 7year old girl infected with the zoonotic trematode, Fasciola gigantica is reported because of the extreme rarity of this condition in our region. Because of the overlap in symptomatology and radiological features, the more common amebic/pyogenic liver abscess in the initial hepatic migratory phase and later choledochal cyst/biliary ascariasis when the parasite was finally located in the extrahepatic bile ducts, were thought of delaying effective treatment. The diagnosis was confirmed only by surgical exploration. The characteristic contrast enhanced computed tomography scan features retrospectively identified were multiple clustered hypodense lesions in the liver with peripheral enhancement in the acute hepatic migratory phase, and periportal tracking in the previously affected areas of the liver with biliary dilatation and a linear hypointense lesion within the common bile duct in the chronic phase. Although a known association, she did not have eosinophilia. This child, who became symptomatic at the age of 5.5years, also appears to be one of the youngest patients reported with Fasciola gigantica. Copyright © 2015 Elsevier Inc. All rights reserved.
Ye, Sheng; Dong, Jia-Hong; Duan, Wei-Dong; Ji, Wen-Bing; Liang, Yu-Rong
2017-03-01
The incidence of biliary complications after living donor adult liver transplantation (LDALT) is still high due to the bile duct variation and necessity reconstruction of multiple small bile ducts. The current surgical management of the biliary variants is unsatisfactory. We evaluated the role of a new surgical approach in a complicated hilar bile duct variant (Nakamura type IV and Nakamura type II) under emergent right lobe LDALT for high model for end-stage liver disease score patients. The common hepatic duct (CHD) and the left hepatic duct (LHD) of the donor were transected in a right-graft including short common trunks with right posterior and anterior bile ducts, whereas the LHD of the donor was anastomosed to the CHD and the common trunks of a right-graft bile duct and the recipient CHD was end-to-end anastomosed. Ten of 13 grafts (Nakamura types II, III, and IV) had two or more biliary orifices after right graft lobectomy; seven patients had biliary complications (53.8%). Later, the surgical innovation was carried out in five donors with variant bile duct (four Nakamura type IV and one type II), and, consequently, no biliary or other complications were observed in donors and recipients during 47-53 months of follow-up; significant differences ( P < 0.05) were found when two stages were compared. Our initial experience suggests that, in the urgent condition of LDALT when an alternative live donor was unavailable, a surgical innovation of cutting part of the CHD trunks including variant right hepatic ducts in a complicated donor bile duct variant may facilitate biliary reconstruction and reduce long-term biliary complications.
Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Conzen, Suzanne D; Karczmar, Gregory S
2017-07-01
High resolution 3D MRI was used to study contrast agent distribution and leakage in normal mouse mammary glands and glands containing in situ cancer after intra-ductal injection. Five female FVB/N mice (~19weeks old) with no detectable mammary cancer and eight C3(1) SV40 Tag virgin female mice (~15weeks old) with extensive in situ cancer were studied. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple and approximately 15μL of a Gadodiamide was injected slowly over 1min into the nipple and throughout the duct on one side of the inguinal gland. Following injection, the mouse was placed in a 9.4T MRI scanner, and a series of high resolution 3D T1-weighted images was acquired with a temporal resolution of 9.1min to follow contrast agent leakage from the ducts. The first image was acquired at about 12min after injection. Ductal enhancement regions detected in images acquired between 12 and 21min after contrast agent injection was five times smaller in SV40 mouse mammary ducts (p<0.001) than in non-cancerous FVB/N mouse mammary ducts, perhaps due to rapid washout of contrast agent from the SV40 ducts. The contrast agent washout rate measured between 12min and 90min after injection was ~20% faster (p<0.004) in SV40 mammary ducts than in FVB/N mammary ducts. These results may be due to higher permeability of the SV40 ducts, likely due to the presence of in situ cancers. Therefore, increased permeability of ducts may indicate early stage breast cancers. Copyright © 2017 Elsevier Inc. All rights reserved.
Schwarz, A.; Beger, H. G.
2005-01-01
Tissue and duct hypertension is considered as a major factor in the etiology of pain in patients with chronic pancreatitis (CP). Duct dilatation is a consequence of duct obstruction due to scars or duct stones. Nevertheless, the procedure of choice, drainage or resection, is still under discussion. We present long-term results of patients operated with duodenum-preserving pancreatic head resection (DPPHR) combined with a Partington-Rochelle duct drainage in cases of chronic pancreatitis with multiple stenosis and dilatation of the side ducts. Methods and patients. From April 1982 to September 2001, in 55 out of 538 patients with chronic pancreatitis, a DPPHR with additionally Partington-Rochelle duct drainage was performed (44 male, 11 female, mean age 45.8 years). Ninety-two percent of the patients suffered from alcoholic pancreatitis. Medical respective pain treatment for chronic pancreatitis was in median 64.5 months prior to surgery. The indications for surgery were in 87% pain, 59% of the patients had an inflammatory mass in the head of the pancreas, 36% a common bile duct stenosis and 5% a severe stenosis of the duodenum. The endocrine function (OGGT) was impaired in 79% of the patients preoperatively. Results. Hospital mortality was 0%, postoperative complications occurred in 11 patients. Follow-up: All except 2 patients were followed up in the outpatient clinic with the mean follow-up time of 69.7 months (8–105 months), the late mortality was 9%. Sixty-eight percent of the patients were completely free of pain, 29% had occasional pain, 3% suffered from a further attack of pancreatitis. Body weight increased in 79%, 58% were professionally rehabilitated. Late postoperative endocrine function was unchanged in 85% (improved in 5%, deteriorated in 10%). Conclusion. The pain control in patients with multiple duct stenosis after duodenum-preserving pancreatic head resection with duct drainage leads to long-standing absence of pain and low recurrence rate of attacks of pancreatitis. PMID:18333173
Using Innovative Technologies for Manufacturing Rocket Engine Hardware
NASA Technical Reports Server (NTRS)
Betts, E. M.; Eddleman, D. E.; Reynolds, D. C.; Hardin, N. A.
2011-01-01
Many of the manufacturing techniques that are currently used for rocket engine component production are traditional methods that have been proven through years of experience and historical precedence. As the United States enters into the next space age where new launch vehicles are being designed and propulsion systems are being improved upon, it is sometimes necessary to adopt innovative techniques for manufacturing hardware. With a heavy emphasis on cost reduction and improvements in manufacturing time, rapid manufacturing techniques such as Direct Metal Laser Sintering (DMLS) are being adopted and evaluated for their use on NASA s Space Launch System (SLS) upper stage engine, J-2X, with hopes of employing this technology on a wide variety of future projects. DMLS has the potential to significantly reduce the processing time and cost of engine hardware, while achieving desirable material properties by using a layered powder metal manufacturing process in order to produce complex part geometries. Marshall Space Flight Center (MSFC) has recently hot-fire tested a J-2X gas generator (GG) discharge duct that was manufactured using DMLS. The duct was inspected and proof tested prior to the hot-fire test. Using a workhorse gas generator (WHGG) test fixture at MSFC's East Test Area, the duct was subjected to extreme J-2X hot gas environments during 7 tests for a total of 537 seconds of hot-fire time. The duct underwent extensive post-test evaluation and showed no signs of degradation. DMLS manufacturing has proven to be a viable option for manufacturing rocket engine hardware, and further development and use of this manufacturing method is recommended.
Differentiating immunoglobulin g4-related sclerosing cholangitis from hilar cholangiocarcinoma.
Tabata, Taku; Kamisawa, Terumi; Hara, Seiichi; Kuruma, Sawako; Chiba, Kazuro; Kuwata, Go; Fujiwara, Takashi; Egashira, Hideto; Koizumi, Koichi; Fujiwara, Junko; Arakawa, Takeo; Momma, Kumiko; Kurata, Masanao; Honda, Goro; Tsuruta, Koji; Itoi, Takao
2013-03-01
Few studies have differentiated immunoglobulin G (IgG) 4-related sclerosing cholangitis (IgG4-SC) from hilar cholangiocarcinoma (CC). Thus, we sought to investigate useful features for differentiating IgG4-SC from hilar CC. We retrospectively compared clinical, serological, imaging, and histological features of six patients with IgG4-SC and 42 patients with hilar CC. In patients with hilar CC, obstructive jaundice was more frequent (p<0.01), serum total bilirubin levels were significantly higher (p<0.05), serum CA19-9 levels were significantly higher (p<0.01), and serum duke pancreatic monoclonal antigen type 2 levels were frequently elevated (p<0.05). However, in patients with IgG4-SC, the serum IgG (p<0.05) and IgG4 (p<0.01) levels were significantly higher and frequently elevated. The pancreas was enlarged in all IgG4-SC patients but only in 17% of hilar CC patients (p<0.01). Salivary and/or lacrimal gland swelling was detected in only 50% of IgG4-SC patients (p<0.01). Endoscopic retrograde cholangiography revealed that the hilar or hepatic duct was completely obstructed in 83% of hilar CC patients (p<0.01). Lower bile duct stenosis, apart from hilar bile duct stenosis, was more frequent in IgG4-SC patients (p<0.01). Bile duct wall thickening in areas without stenosis was more frequent in IgG4-SC patients (p<0.01). An integrated diagnostic approach based on clinical, serological, imaging, and histological findings is necessary to differentiate IgG4-SC from hilar CC.
Using Innovative Techniques for Manufacturing Rocket Engine Hardware
NASA Technical Reports Server (NTRS)
Betts, Erin M.; Reynolds, David C.; Eddleman, David E.; Hardin, Andy
2011-01-01
Many of the manufacturing techniques that are currently used for rocket engine component production are traditional methods that have been proven through years of experience and historical precedence. As we enter into a new space age where new launch vehicles are being designed and propulsion systems are being improved upon, it is sometimes necessary to adopt new and innovative techniques for manufacturing hardware. With a heavy emphasis on cost reduction and improvements in manufacturing time, manufacturing techniques such as Direct Metal Laser Sintering (DMLS) are being adopted and evaluated for their use on J-2X, with hopes of employing this technology on a wide variety of future projects. DMLS has the potential to significantly reduce the processing time and cost of engine hardware, while achieving desirable material properties by using a layered powder metal manufacturing process in order to produce complex part geometries. Marshall Space Flight Center (MSFC) has recently hot-fire tested a J-2X gas generator discharge duct that was manufactured using DMLS. The duct was inspected and proof tested prior to the hot-fire test. Using the Workhorse Gas Generator (WHGG) test setup at MSFC?s East Test Area test stand 116, the duct was subject to extreme J-2X gas generator environments and endured a total of 538 seconds of hot-fire time. The duct survived the testing and was inspected after the test. DMLS manufacturing has proven to be a viable option for manufacturing rocket engine hardware, and further development and use of this manufacturing method is recommended.
Laparoscopic bile duct injury: understanding the psychology and heuristics of the error.
Dekker, Sidney W A; Hugh, Thomas B
2008-12-01
Bile duct injury is an important unsolved problem of laparoscopic cholecystectomy, occurring with unacceptable frequency even in the hands of experienced surgeons. This suggests that a systemic predisposition to the injury is intrinsic to cholecystectomy and indicates that an analysis of the psychology and heuristics of surgical decision-making in relation to duct identification may be a guide to prevention. Review of published reports on laparoscopic bile duct injury from 1997 to 2007 was carried out. An analysis was also carried out of the circumstances of the injuries in 49 patients who had transection of an extrahepatic bile duct and who were referred for reconstruction or were assessed in a medicolegal context. Special emphasis was placed on identifying the possible psychological aspects of duct misidentification. Review of published work showed an emphasis on the technical aspects of correct identification of the cystic duct, with few papers addressing the heuristics and psychology of surgical decision-making during cholecystectomy. Duct misidentification was the cause of injury in 42 out of the 49 reviewed patients (86%). The injury was not recognized at operation in 70% and delay in recognition persisted into the postoperative period in 57%. Underestimation of risk, cue ambiguity and visual misperception ('seeing what you believe') were important factors in misidentification. Delay in recognition of the injury is a feature consistent with cognitive fixation and plan continuation, which help construct and sustain the duct misidentification during the operation and beyond. Changing the 'culture' of cholecystectomy is probably the most effective strategy for preventing laparoscopic bile duct injury, especially if combined with new technical approaches and an understanding of the heuristics and psychology of the duct misidentification error. Training of surgeons for laparoscopic cholecystectomy should emphasize the need to be alert for cues that the incorrect duct is being dissected or that a bile duct injury might have occurred. Surgeons may also be trained to accept the need for plan modification, to seek cues that refute a given hypothesis and to apply 'stopping rules' for modifying or converting the operation.
New Generation of ELF/VLF Wave Injection Experiments for HAARP
NASA Astrophysics Data System (ADS)
Sonwalkar, V. S.; Reddy, A.; Watkins, B. J.
2016-12-01
We present a ray tracing study to investigate the feasibility of a new generation of wave injection experiments from HAARP transmitter (L 4.9). Highly successful whistler mode wave injection experiments from SIPLE station, Antarctica, have established the importance of such experiments to study magnetospheric wave-particle interactions, and for cold and hot plasma diagnostics [Helliwell and Katsufrakis, 1974; Carpenter and Miller, 1976; Sonwalkar et al., 1997]. Modulated heating experiments from HAARP have shown that it is possible to launch ELF/VLF waves into the magnetosphere that can be observed on the ground after one-, two-, and multi-hop ducted propagation [Inan et al., 2004]. Recent research has also shown that ionospheric heating experiments using HAARP can lead to the formation of magnetospheric ducts [e.g. Milikh et al., 2010; Fallen et al., 2011]. Collectively, these results indicate that the HAARP (or similar) transmitter can be used first to form ducts on nearby L shells, and then to inject and trap transmitter generated ELF/VLF waves in those ducts. Ray tracing studies using a model magnetosphere shows that ELF/VLF waves in a few kilohertz range can be trapped in ducts with L shells near the HAARP transmitter. For example, 1.5 kHz waves injected from L shell = 4.9 and altitude = 200 km can be trapped in ducts located within 0.3 L of the transmitter L-shell. The duct parameters needed for ray-trapping are typically duct width dL 0.1-0.3 and duct enhancement factor dNe/Ne 10-20% or more. The location of plasmapause with respect to transmitter plays a role in the nature of trapping. The duct locations and parameters required for trapping ELF/VLF waves inside the ducts are consistent with past observations of ducts generated by the HAARP transmitter. Ray tracing calculations provide trapped wave normal angles, time delays, resonant energetic electron energy, estimates of wave intensity inside the duct, on the ground, and on satellites such DEMETER, Van Allen probe, and planned DSX. We discuss the potential of a new generation of wave injection experiments from HAARP transmitter to investigate: duct and ELF/VLF generation by high power HF transmitters, whistler mode wave propagation and wave particle interactions, and cold and hot plasma diagnostics.
The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems
NASA Astrophysics Data System (ADS)
Wilson, Eric J. H.
2011-12-01
This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both heating and cooling energy, and ranges from 7% in Los Angeles, CA to 13% in Fairbanks, AK. These results assume a leaky and uninsulated duct system. The potential for savings from cleaning decreases if duct insulation is in place or sealing has been performed. The potential for energy savings is directly related to the distribution system's thermal efficiency, with air conditioner performance also playing a minor role. Results for small commercial buildings with constant air volume HVAC systems and leaky and uninsulated duct systems span a wider range: from -12% in Miami, FL to 30% in Minneapolis, MN. However, for improved ducts or ducts in the conditioned space, small commercial HVAC source energy savings is always negative (down to -17%) for flowrates degradation in the 0--40% range. The sensitivity of these results to duct characteristics (location, leakage, and insulation) and the after-cleaning flowrate, as it varies from an ideal flowrate, was also evaluated. Energy savings can reach up to 80% for some scenarios where clean airflow is severely restricted down to 20% of ideal by poor duct layout or other obstructions not removable by cleaning. In addition, a simplified spreadsheet tool was developed for technicians to use in the field to estimate potential savings resulting from a system cleaning. Measuring the temperature rise across the furnace was found to give less uncertainty than measuring the pressure rise and assuming a fan curve. Despite the uncertainty, the tool can give a general idea of the range of savings possible under various conditions.
Gemcitabine, Oxaliplatin, Tarceva &/or Cisplatin in HCC & Biliary Tree Cancers
2018-06-27
Hepatocellular Carcinoma; Cholangiocellular Carcinoma; Cholangiocarcinoma of the Extrahepatic Bile Duct; Bile Duct Cancer; Periampullary Adenocarcinoma; Gallbladder Cancer; Extrahepatic Bile Duct Cancer
Design and performance of duct acoustic treatment
NASA Technical Reports Server (NTRS)
Motsinger, R. E.; Kraft, R. E.
1991-01-01
The procedure for designing acoustic treatment panels used to line the walls of aircraft engine ducts and for estimating the resulting suppression of turbofan engine duct noise is discussed. This procedure is intended to be used for estimating noise suppression of existing designs or for designing new acoustic treatment panels and duct configurations to achieve desired suppression levels.
Influence of Resin Duct Size and Number on Oleoresin Flow in the Southern Pines
John D. Hodges; William W. Elam; Donald R. Bluhm
1981-01-01
The number of radial resin ducts was significantly higher in slash pines than in loblolly, longleaf, or shortleaf. Average width of resin ducts was less in shortleaf than in the other three species. Flow rate of oleoresin was not correlated with size or number of resin ducts for any of the four species.
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Are duct burners and waste heat... Stationary Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam...
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Are duct burners and waste heat... Stationary Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam...
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Are duct burners and waste heat... Stationary Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam...
[Syncrhonous carcinosarcoma of the extrahepatic bile duct and gallbladder.
Páramo, Ana Alberca; Valverde, David Padilla; Campos, Pedro Villarejo; Santos, Esther Pilar Garcia; Puche, Jose Luis Bertelli; Guerrero, Paloma Núńez; Delgado, Margarita; Fernindez, Jesus Martin
2016-03-01
Carcinosarcoma is a malignant neoplasm characterized for intermingled epithelial and mesenchymal components. A preoperative suspected diagnosis will allow a radical therapy avoiding a very bad prognosis. We report on a male patient who was operated in our Service with diagnosis of synchronous carcinosarcoma of gallbladder and extrahepatic bile duct and a review of the Medical Literature. A gallblader carcinosarcoma showing extension into common bile duct is very rare, a carcinosarcoma of the bile duct is exceptional, and a synchronous carcinosarcoma ofthe bile duct and gallbladder has not been reported previously.
Chitin in the Silk Gland Ducts of the Spider Nephila edulis and the Silkworm Bombyx mori
Davies, Gwilym J. G.; Knight, David P.; Vollrath, Fritz
2013-01-01
Here we report the detection and localisation of chitin in the cuticle of the spinning ducts of both the spider Nephila edulis and the silkworm Bombyx mori. Our observations demonstrate that the duct walls of both animals contain chitin notwithstanding totally independent evolutionary pathways of the systems. We conclude that chitin may well be an essential component for the construction of spinning ducts; we further conclude that in both species chitin may indicate the evolutionary origin of the spinning ducts. PMID:24015298
2014-09-08
Adenocarcinoma of the Gallbladder; Adenocarcinoma With Squamous Metaplasia of the Gallbladder; Adult Primary Cholangiocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Localized Unresectable Adult Primary Liver Cancer; Metastatic Extrahepatic Bile Duct Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Stage II Gallbladder Cancer; Stage IIIA Gallbladder Cancer; Stage IIIB Gallbladder Cancer; Stage IVA Gallbladder Cancer; Stage IVB Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer
Using the surface panel method to predict the steady performance of ducted propellers
NASA Astrophysics Data System (ADS)
Cai, Hao-Peng; Su, Yu-Min; Li, Xin; Shen, Hai-Long
2009-12-01
A new numerical method was developed for predicting the steady hydrodynamic performance of ducted propellers. A potential based surface panel method was applied both to the duct and the propeller, and the interaction between them was solved by an induced velocity potential iterative method. Compared with the induced velocity iterative method, the method presented can save programming and calculating time. Numerical results for a JD simplified ducted propeller series showed that the method presented is effective for predicting the steady hydrodynamic performance of ducted propellers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Rudd, Armin
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.
Arkelyan, A.M.; Rickard, C.L.
1962-04-17
A gate valve for controlling the flow of fluid in separate concentric ducts or channels by means of a single valve is described. In one position, the valve sealing discs engage opposed sets of concentric ducts leading to the concentric pipes defining the flow channels to block flow therethrough. In another position, the discs are withdrawn from engagement with the opposed ducts and at the same time a bridging section is interposed therebetween to define concentric paths coextensive with and connecting the opposed ducts to facilitate flow therebetween. A wedge block arrangement is employed with each sealing disc to enable it to engage the ducts. The wedge block arrangement also facilitates unobstructcd withdrawal of the discs out of the intervening space between the sets of ducts. (AEC)
Common bile duct stricture as a late complication of upper abdominal radiotherapy.
Cherqui, D; Palazzo, L; Piedbois, P; Charlotte, F; Duvoux, C; Duron, J J; Fagniez, P L; Valla, D
1994-06-01
We report the cases of two patients who developed symptomatic common bile duct stricture 10 years after upper abdominal radiotherapy for malignant lymphoma. Both patients were in complete remission and presented with marked obstructive jaundice. Endosonography was useful in both cases and showed segmental thickening of the bile duct wall narrowing in the lumen. Both patients underwent surgical exploration, confirming biliary obstruction due to intrinsic wall thickening, and had successful biliary drainage by Roux-en-Y hepatico-jejunostomy. Histological examination of the resected bile duct, in one case, and of a bile duct biopsy, in the other, was consistent with late irradiation injury. We conclude that stricture may be a delayed consequence of radiotherapy applied to normal bile ducts.
Da, Yun-Meng; Niu, Kai-Yu; Liu, Shu-Ya; Wang, Ke; Wang, Wen-Juan; Jia, Jing; Qin, Li-Hua; Bai, Wen-Pei
2017-03-14
Cimicifuga racemosa is one of the herbs used for the treatment of climacteric syndrome, and it has been cited as an alternative therapy to estrogen. Apart from hectic fevers, dyspareunia and so on, dry mouth also increase significantly after menopause. It has not yet been reported whether C. racemosa has any impact on the sublingual gland, which may relate to dry mouth. In an attempt to determine this, we have compared the effects of estrogen and C. racemosa on the sublingual gland of ovariectomized rats. HE staining showed that the acinar cell area had contracted and that the intercellular spaces were broadened in the OVX (ovariectomized rats) group, while treatment with estradiol (E2) and iCR (isopropanolic extract of C. racemosa) improved these lesions. Transmission electron microscopy showed that rough endoplasmic reticulum expansion in mucous and serous acinar epithelial cells and apoptotic cells was more commonly seen in the OVX group than in the SHAM (sham-operated rats) group. Mitochondria and plasma membrane infolding lesions in the striated ducts were also observed. These lesions were alleviated by both treatments. It is of note that, in the OVX + iCR group, the volume of mitochondria in the striated duct was larger than in other groups. Immunohistochemical staining showed that the ratio of caspase-3 positive cells was significantly increased in the acinar cells of the OVX group compared with the SHAM group (p < 0.05); and the MA (mean absorbance) of caspase-3 in the striated ducts also increased (p < 0.05). Estradiol decreased the ratio of caspase-3 positive cells and the MA of caspase-3 in striated ducts significantly (p < 0.05). ICR also reduced the ratio of caspase-3 positive cells and the MA in the striated ducts (p < 0.05), but the reduction of the MA in striated ducts was inferior to that of the OVX + E2 group (p < 0.05). Both estradiol and iCR can inhibit subcellular structural damage, and down-regulate the expression of caspase-3 caused by ovariectomy, but their effects were not identical, suggesting that both drugs confer a protective effect on the sublingual gland of ovariectomized rats, but that the specific location and mechanism of action producing these effects were different.
Quiet Clean Short-haul Experimental Engine (QCSEE) Under-The-Wing (UTW) composite nacelle
NASA Technical Reports Server (NTRS)
Johnston, E. A.
1978-01-01
The detail design of the under the wing experimental composite nacelle components is summarized. Analysis of an inlet, fan bypass duct doors, core cowl doors, and variable fan nozzle are given. The required technology to meet propulsion system performance, weight, and operational characteristics is discussed. The materials, design, and fabrication technology for quiet propulsion systems which will yield installed thrust to weight ratios greater than 3.5 to 1 are described.
Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp; Yoshida, Rie, E-mail: yagir@hirakata.kmu.ac.jp
PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct andmore » leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.« less
PMR Graphite Engine Duct Development
NASA Technical Reports Server (NTRS)
Stotler, C. L.; Yokel, S. A.
1989-01-01
The objective was to demonstrate the cost and weight advantages that could be obtained by utilizing the graphite/PMR15 material system to replace titanium in selected turbofan engine applications. The first component to be selected as a basis for evaluation was the outer bypass duct of the General Electric F404 engine. The operating environment of this duct was defined and then an extensive mechanical and physical property test program was conducted using material made by processing techniques which were also established by this program. Based on these properties, design concepts to fabricate a composite version of the duct were established and two complete ducts fabricated. One of these ducts was proof pressure tested and then run successfully on a factory test engine for over 1900 hours. The second duct was static tested to 210 percent design limit load without failure. An improved design was then developed which utilized integral composite end flanges. A complete duct was fabricated and successfully proof pressure tested. The net results of this effort showed that a composite version of the outer duct would be 14 percent lighter and 30 percent less expensive that the titanium duct. The other type of structure chosen for investigation was the F404 fan stator assembly, including the fan stator vanes. It was concluded that it was feasible to utilize composite materials for this type structure but that the requirements imposed by replacing an existing metal design resulted in an inefficient composite design. It was concluded that if composites were to be effectively used in this type structure, the design must be tailored for composite application from the outset.
Lesions of the segmental and lobar hepatic ducts.
Longmire, W P; Tompkins, R K
1975-01-01
Despite reports to the contrary, unobstructed drainage of 50% of an otherwise normal liver through either the right or left uninfected hepatic duct is adequate to restore normal liver function, even if the obstructed lobe remains in place. An undrained liver lobe, if present, may require no further treatment. As long as it is completely obstructed and uninfected, it will undergo a progressive asymptomatic atrophy. Cholangitis invariably develops behind a partial lobar ductal obstruction, producing jaundice, pruritis, and fever. Unless unobstructed, uninfected biliary flow can be achieved through a segmental or lobar duct, it is better that the duct be completely obstructed and the affected liver parenchyma allowed to atrophy, provided there is normal biliary flow from the residual 50% of liver. This concept is important in the management of injured anomalous segmental or lobar hepatic duct and in the palliative treatment of bile duct carcinoma. Localized intrahepatic infections communicating with abnormal biliary ducts will require hepatic resection of the infected parenchyma and ducts for cure. The abnormality may be saccular dilatation of the intrahepatic ductal system with abscess formation or intrahepatic abscess associated with stenosis of the ductal system from trauma to the duct, to the duct and liver, or to retained intrahepatic stones. Diffusely situated intrahepatic abscesses secondary to ductal abnormalities can be treated with systemic antibiotics, local drainage of a dmoninant abscess, and efforts to improve biliary drainage. Images Fig. 4. Fig. 5. Fig. 6. Fig. 8. Fig. 9. Fig. 10. Figs. 11A and B Figs. 12A and B. Fig. 13. Fig. 14. Fig. 15. Fig. 16. Fig. 17. PMID:1180585
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Are duct burners and waste heat... Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam generating units...
40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Are duct burners and waste heat... Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam generating units...
Results and comparison of Hall and DW duct experiments
NASA Technical Reports Server (NTRS)
Smith, J. M.; Morgan, J. L.
1982-01-01
Experimental data from recent tests of a 45 deg diagonal wall duct are presented and compared with the results of a similar Hall duct. It is shown that while the peak power density of the two devices is approximately equal that the diagonal wall duct produces greater total power output due to its ability to better utilize the available magnetic field.
Bile duct epithelial tight junctions and barrier function
Rao, R.K.; Samak, G.
2013-01-01
Bile ducts play a crucial role in the formation and secretion of bile as well as excretion of circulating xenobiotic substances. In addition to its secretory and excretory functions, bile duct epithelium plays an important role in the formation of a barrier to the diffusion of toxic substances from bile into the hepatic interstitial tissue. Disruption of barrier function and toxic injury to liver cells appear to be involved in the pathogenesis of a variety of liver diseases such as primary sclerosing cholangitis, primary biliary cirrhosis and cholangiocarcinoma. Although the investigations into understanding the structure and regulation of tight junctions in gut, renal and endothelial tissues have expanded rapidly, very little is known about the structure and regulation of tight junctions in the bile duct epithelium. In this article we summarize the current understanding of physiology and pathophysiology of bile duct epithelium, the structure and regulation of tight junctions in canaliculi and bile duct epithelia and different mechanisms involved in the regulation of disruption and protection of bile duct epithelial tight junctions. This article will make a case for the need of future investigations toward our understanding of molecular organization and regulation of canalicular and bile duct epithelial tight junctions. PMID:24665411
Modified duval procedure for small-duct chronic pancreatitis without head dominance.
Oida, Takatsugu; Aramaki, Osamu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao
2011-01-01
In the case of small-duct chronic pancreatitis, surgery for pain relief is broadly divided into resection and drainage procedures. These procedures should be selected according to the location of dominant lesion, diameter of the pancreatic duct and extent of the disease. The appropriate procedure for the treatment of small-duct chronic pancreatitis, especially small-duct chronic pancreatitis without head dominance, remains controversial. We developed the modified Duval procedure for the treatment of small-duct chronic pancreatitis without head dominance and determined the efficacy of this procedure. We retrospectively studied 14 patients who underwent surgical drainage with or without pancreatic resection for chronic pancreatitis with small pancreatic duct (<7mm) without head dominance. These patients were divided into 2 groups; the modified Puestow procedure group and the modified Duval procedure group. No complications occurred in the modified Duval group. In the modified Puestow procedure group, complete and partial pain relief were observed in 62.5%, and 37.5% of patients respectively. In contrast, complete pain relief was observed in all the patients in the modified Duval procedure group. Our modified Duval procedure is useful and should be considered the appropriate surgical technique for the treatment of small-duct chronic pancreatitis without head dominance.
Furusawa, Norihiko; Kobayashi, Akira; Yokoyama, Takahide; Shimizu, Akira; Motoyama, Hiroaki; Kanai, Keita; Arakura, Norikazu; Yamada, Akira; Kitou, Yoshihiro; Miyagawa, Shin-Ichi
2015-08-01
Among the intrahepatic bile ducts, the biliary system of the left medial sectional bile duct (B4) is known to have relatively complex patterns. The records of 500 patients who had been diagnosed as having hepato-pancreatico-biliary disease were retrospectively studied for anatomical biliary variations of the left liver with special reference to the drainage system of B4 using magnetic resonance images. The left hepatic duct was present in 494 patients (98.8%), whereas it was lacking in 6 patients (1.2%), and these patients exhibited the following B4 confluence patterns: B4 drained into the common hepatic duct in 2 patients (.4%), the right anterior sectional bile duct in 3 patients (.6%), and the right posterior sectional bile duct in 1 patient (.2%). The left hepatic duct was absent more frequently in patients with portal venous variations than in patients with a common branching pattern (8.2% vs .4%, P = .0011). The presently reported data are useful for obtaining a better understanding of the surgical anatomy of the biliary system of the left liver. Copyright © 2015 Elsevier Inc. All rights reserved.
Analysis of sound propagation in ducts using the wave envelope concept
NASA Technical Reports Server (NTRS)
Baumeister, K. J.
1974-01-01
A finite difference formulation is presented for sound propagation in a rectangular two-dimensional duct without steady flow for plane wave input. Before the difference equations are formulated, the governing Helmholtz equation is first transformed to a form whose solution does not oscillate along the length of the duct. This transformation reduces the required number of grid points by an order of magnitude, and the number of grid points becomes independent of the sound frequency. Physically, the transformed pressure represents the amplitude of the conventional sound wave. Example solutions are presented for sound propagation in a one-dimensional straight hard-wall duct and in a two-dimensional straight soft-wall duct without steady flow. The numerical solutions show evidence of the existence along the duct wall of a developing acoustic pressure diffusion boundary layer which is similar in nature to the conventional viscous flow boundary layer. In order to better illustrate this concept, the wave equation and boundary conditions are written such that the frequency no longer appears explicitly in them. The frequency effects in duct propagation can be visualized solely as an expansion and stretching of the suppressor duct.
CFD analysis of gas explosions vented through relief pipes.
Ferrara, G; Di Benedetto, A; Salzano, E; Russo, G
2006-09-21
Vent devices for gas and dust explosions are often ducted to safe locations by means of relief pipes. However, the presence of the duct increases the severity of explosion if compared to simply vented vessels (i.e. compared to cases where no duct is present). Besides, the identification of the key phenomena controlling the violence of explosion has not yet been gained. Multidimensional models coupling, mass, momentum and energy conservation equations can be valuable tools for the analysis of such complex explosion phenomena. In this work, gas explosions vented through ducts have been modelled by a two-dimensional (2D) axi-symmetric computational fluid dynamic (CFD) model based on the unsteady Reynolds Averaged Navier Stokes (RANS) approach in which the laminar, flamelet and distributed combustion models have been implemented. Numerical test have been carried out by varying ignition position, duct diameter and length. Results have evidenced that the severity of ducted explosions is mainly driven by the vigorous secondary explosion occurring in the duct (burn-up) rather than by the duct flow resistance or acoustic enhancement. Moreover, it has been found out that the burn-up affects explosion severity due to the reduction of venting rate rather than to the burning rate enhancement through turbulization.
NASA Technical Reports Server (NTRS)
Plumblee, H. E., Jr.; Dean, P. D.; Wynne, G. A.; Burrin, R. H.
1973-01-01
The results of an experimental and theoretical study of many of the fundamental details of sound propagation in hard wall and soft wall annular flow ducts are reported. The theory of sound propagation along such ducts and the theory for determining the complex radiation impedance of higher order modes of an annulus are outlined, and methods for generating acoustic duct modes are developed. The results of a detailed measurement program on propagation in rigid wall annular ducts with and without airflow through the duct are presented. Techniques are described for measuring cut-on frequencies, modal phase speed, and radial and annular mode shapes. The effects of flow velocity on cut-on frequencies and phase speed are measured. Comparisons are made with theoretical predictions for all of the effects studies. The two microphone method of impedance is used to measure the effects of flow on acoustic liners. A numerical study of sound propagation in annular ducts with one or both walls acoustically lined is presented.
Sound radiation from a flanged inclined duct.
McAlpine, Alan; Daymond-King, Alex P; Kempton, Andrew J
2012-12-01
A simple method to calculate sound radiation from a flanged inclined duct is presented. An inclined annular duct is terminated by a rigid vertical plane. The duct termination is representative of a scarfed exit. The concept of a scarfed duct has been examined in turbofan aero-engines as a means to, potentially, shield a portion of the radiated sound from being transmitted directly to the ground. The sound field inside the annular duct is expressed in terms of spinning modes. Exterior to the duct, the radiated sound field owing to each mode can be expressed in terms of its directivity pattern, which is found by evaluating an appropriate form of Rayleigh's integral. The asymmetry is shown to affect the amplitude of the principal lobe of the directivity pattern, and to alter the proportion of the sound power radiated up or down. The methodology detailed in this article provides a simple engineering approach to investigate the sound radiation for a three-dimensional problem.
Davies, G J G; Knight, D P; Vollrath, F
2013-10-01
Silks are fibres produced by spiders, some insects and even a crustacean, and are formed from protein solution by a pulltrusion process that is not well understood. Here we describe three aspects of the functional anatomy of the spinning apparatus in a spider: (i) changes in the diameter of the duct of the silk gland along its length for individuals at different stages of development, (ii) the correlation between the morphology of the duct and size and (iii) changes in the thickness of the wall of the duct. We conclude that in the distal part of the duct both the lumen's geometry and change in diameter with distance remains remarkably constant as the duct increases in length from moult to moult as the spider grows. This suggests constancy in the region where the nascent silk filament is drawn down within the lumen of the duct, which is likely to be fundamental for forming strong and tough fibres. Copyright © 2013 Elsevier Ltd. All rights reserved.
Turbofan aft duct suppressor study
NASA Technical Reports Server (NTRS)
Syed, A. A.; Motsinger, R. E.; Fiske, G. H.; Joshi, M. C.; Kraft, R. E.
1983-01-01
Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.
Guelrud, M; Mendoza, S; Vicent, S; Gomez, M; Villalta, B
1983-02-01
To determine the significance of manometric pressure, measurements of the sphincter of Oddi in a control group and in patients with cholelithiasis with common duct stones with and without recurrent pancreatitis were studied. Sphincter of Oddi pressure was recorded continuously and by station pull-through by a triple lumen catheter. The basal sphincter of Oddi pressure, the mean pressure gradient between common duct and duodenum, and the sphincter of Oddi wave amplitude were measured. There was no significant difference between control subjects and patients with gallstones and common duct stones. In patients with common duct stones and recurrent pancreatitis the basal sphincter of Oddi pressure, the pressure gradient between common duct and duodenum, and the wave amplitude were significantly increased over control patients. These studies suggest that abnormalities in the sphincter of Oddi motor function are more common in patients with common duct stones with recurrent pancreatitis than in similar patients without pancreatitis.
Double Gallbladder Originating from Left Hepatic Duct: A Case Report and Review of Literature
Gorecki, Piotr J.; Andrei, Valeriu E; Musacchio, Tito
1998-01-01
Background: Double gallbladder is a rare anomaly of the biliary tract. Double gallbladder arising from the left hepatic duct was previously reported only once in the literature. Case Report: A case of symptomatic cholelithiasis in a double gallbladder, diagnosed on preoperative ultrasound, computed tomography (CT) and endoscopic retrograde cholangiopancreatogram (ERCP) is reported. At laparoscopic cholangiography via the accessory gallbladder no accessory cystic duct was visualized. After conversion to open cholecystectomy, the duplicated gallbladder was found to arise directly from the left hepatic duct; it was resected and the duct repaired. Conclusions: We emphasize that a careful intraoperative cholangiographic evaluation of the accessory gallbladder is mandatory in order to prevent inadvertent injury to bile ducts, since a large variety of ductal abnormality may exist. PMID:10036124
Analyses of radiation impedances of finite cylindrical ducts
NASA Astrophysics Data System (ADS)
Shao, W.; Mechefske, C. K.
2005-08-01
To aid in understanding the characteristics of acoustic radiation from finite cylindrical ducts with infinite flanges, mathematical expressions of generalized radiation impedances at the open ends have been developed. Newton's method is used to find the complex wavenumbers of radial modes for the absorption boundary condition. The self-radiation impedances and mutual impedances for some acoustic modes are calculated for the ducts with rigid and absorption walls. The results show that the acoustical conditions of the duct walls have a significant influence on the radiation impedance. The acoustical interaction between the two open ends of the ducts cannot be neglected, especially for plane waves. To increase the wall admittance will reduce this interference effect. This study creates the possibility for simulating the sound field inside finite ducts in future work.
NASA Technical Reports Server (NTRS)
Fuller, C. R.
1984-01-01
Sound propagation in infinite, semiinfinite, and finite circular ducts with circumferentially varying wall admittances is investigated analytically. The infinite case is considered, and an example demonstrates the effects of wall-admittance distribution on dispersion characteristics and mode shapes. An exact solution is obtained for the semiinfinite case, a circular duct with a flanged opening: sidelobe suppression and circumferential-mode energy scattering leading to radiated-field asymmetry are found. A finite duct system with specified hard-walled pressure sources is examined in detail, evaluating reflection coefficients, transmission losses, and radiated-field directivity. Graphs and diagrams are provided, and the implications of the results obtained for the design of aircraft-turbofan inlet liners are discussed.
Cylindrical diffuser performance using a truncated plug nozzle
NASA Technical Reports Server (NTRS)
Galanga, F. L.; Mueller, T. J.
1976-01-01
Cylindrical diffuser performance for a truncated plug nozzle without external flow was tested in a blowdown wind tunnel. The nozzle was designed for an exit Mach number of 1.9 and the plug was conical in shape from the throat and converged to the axis of symmetry at an angle of 10 degrees. The diffuser section was fashioned into two 13.97 cm lengths to facilitate boring of the duct diameter and to allow for testing of two different duct lengths. A slotted hypotube was installed in the base of the diffuser to measure pressure distribution down the centerline of the diffuser. The data obtained included: the typical centerline and sidewall pressure ratio variation along the diffuser, cell pressure ratio vs overall pressure ratio for long and short diffusers and a comparison of minimum experimental cell pressure ratio vs area ratio.
Lightweight Forms for Epoxy/Aramid Ducts
NASA Technical Reports Server (NTRS)
Mix, E. W.; Anderson, A. N.; Bedford, Donald L., Sr.
1986-01-01
Aluminum mandrels easy to remove. Lightweight aluminum mandrel for shaping epoxy/aramid ducts simplifies and speeds production. In new process, glass-reinforced epoxy/aramid cloth wrapped on aluminum mandrel. Stainless-steel flanges and other hardware fitted on duct and held by simple tooling. Entire assembly placed in oven to cure epoxy. After curing, assembly placed in alkaline bath dissolves aluminum mandrel in about 4 hours. Epoxy/aramid shell ready for use as duct. Aluminum mandrel used to make ducts of various inside diameters up to 6 in. Standard aluminum forms used. Conventional tube-bending equipment produces requisite curves in mandrels.
Leaf seal for transition duct in turbine system
Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray
2013-06-11
A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a leaf seal contacting the interface member to provide a seal between the interface member and the turbine section.
Choleperitoneum due to intrahepatic bile duct rupture - case report.
Simion, L; Straja, Dn; Prunoiu, Vm; Alecu, M; Brătucu, E
2014-01-01
Non-traumatic perforations of the bile ducts are unfrequently encountered entities, all the more when they affect the intrahepatic bile ducts, exteriorizing their biliary content in the great peritoneal cavity. Reporting such a case has determined the authors to perform a careful overview of the cases present in the literature. An observation that can be made based on these is that the obstruction of the main bile duct due to lithiasis determines, by pressure increase, the dilation of the bile system branches, all on the background of an unknown malformation of the intrahepatic bile ducts. Celsius.
Preliminary Full-Scale Wind-Tunnel Investigation of Wing Ducts for Radiators, Special Report
NASA Technical Reports Server (NTRS)
Silverstein, Abe; Nickle, F. R.
1938-01-01
Wing ducts for liquid-cooled engine radiators have been investigated in the N.A.C.A. full-scale wind tunnel on a large model airplane. Th e tests were made to determine the relative merits of several types of duct and radiator installations for an airplane of a particular des ign. In the test program the principal duct dimensions were system atically varied, and the results are therefore somewhat applicable to the general problems of wing duct design, although they should be co nsidered as preliminary and only indicative of the inherent possibil ities.
Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts.
Isayama, Hiroyuki; Nakai, Yousuke; Hamada, Tsuyoshi; Matsubara, Saburo; Kogure, Hirofumi; Koike, Kazuhiko
2016-12-01
Self-expandable metallic stent (SEMS) was an effective biliary endoprosthesis. Mechanical properties of SEMS, radial and axial force (RF, AF), may play important roles in the bile duct after placement. RF was well known dilation force and influenced on the occurrence of migration. AF, newly proposed by this author, was defined as the recovery force when the SEMS vended. AF was related with the cause of bile duct kinking, pancreatitis, and cholecystitis due to the compression of the bile duct, orifice of the cystic duct, and pancreatic orifice. Ideal SEMS may show high RF and low AF.
Choledochoscopic Holmium Laser Lithotripsy for Difficult Bile Duct Stones.
Lv, Shangdong; Fang, Zheping; Wang, Aidong; Yang, Jian; Zhang, Wenlong
2017-01-01
The aim of this study was to evaluate the feasibility and efficacy of choledochoscopic holmium laser lithotripsy as a means of removing resistant extrahepatic and intrahepatic bile duct stones. Clinical data on 28 patients who had undergone choledochoscopic holmium laser lithotripsy were analyzed. Complete stone clearance was obtained in 24 patients; small numbers of residual stones in the left or right hepatic duct were found in 4 patients. No severe complications such as hemobilia and bile duct injuries occurred. Choledochoscopic holmium laser lithotripsy is a simple, safe, and effective treatment method for patients with resistant bile duct stones.
Generator stator core vent duct spacer posts
Griffith, John Wesley; Tong, Wei
2003-06-24
Generator stator cores are constructed by stacking many layers of magnetic laminations. Ventilation ducts may be inserted between these layers by inserting spacers into the core stack. The ventilation ducts allow for the passage of cooling gas through the core during operation. The spacers or spacer posts are positioned between groups of the magnetic laminations to define the ventilation ducts. The spacer posts are secured with longitudinal axes thereof substantially parallel to the core axis. With this structure, core tightness can be assured while maximizing ventilation duct cross section for gas flow and minimizing magnetic loss in the spacers.
Complications and management of forgotten long-term biliary stents.
Sohn, Se Hoon; Park, Jae Hyun; Kim, Kook Hyun; Kim, Tae Nyeun
2017-01-28
To evaluate complications and management outcomes of retained long-term plastic biliary stents. Endoscopic plastic biliary stent placement was performed in 802 patients at Yeungnam University Hospital between January 2000 and December 2014. Follow-up loss with a subsequently forgotten stent for more than 12 mo occurred in 38 patients. We retrospectively examined the cause of biliary stent insertion, status of stents, complications associated with biliary stents and management outcomes of long-term plastic biliary stents. Continuous variables were analyzed using the t test. Observed frequencies in subsets of the study population were compared using Fisher's exact test and χ 2 tests. Statistical significance was defined as P < 0.05 (two-tailed). Mean age of patients was 73.7 ± 12 years and male-to-female ratio was 2.2:1. Indications of plastic biliary stent insertion were bile duct stones (63.2%, 24/38) and benign bile duct stricture (52.6%, 20/38). Mean duration of retained plastic stent was 22.6 ± 12.2 mo, and in 10 cases (26.3%), stents were retained for more than 24 mo. Common bile duct (CBD) stones or sludge were found in most cases (92.1%, 35/38). The most common complication was acute cholangitis (94.7%, 36/38). Stent removal by endoscopic approach was successfully performed in 92.1% (35/38) of the cases. In 3 cases, an additional plastic stent was inserted alongside the previous stent due to failure of the stent removal. Endoscopic removal of bile duct stones was successful in 73.7% (28/38) of the cases. When patients were divided into two groups by duration of stent placement (12 to 24 mo vs over 24 mo), there were no differences in the development of cholangitis, presence of biliary stones, and success rate of endoscopic removal of stones and biliary stents. The most common complication of retained long-term plastic biliary stents was acute cholangitis associated with CBD stones. Endoscopic management was successfully performed in most cases.
Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.
Celebi, Ahmet; Demir, Ibrahim Halil; Saritaş, Türkay; Dedeoğlu, Reyhan; Yucel, Ilker Kemal; Demir, Fadli; Erdem, Abdullah
2013-11-15
We sought to investigate the safety, efficacy, and follow-up results of percutaneous patent ductus arteriosus (PDA) closure using the novel Cardi-O-Fix duct occluder (CDO), a device similar to but less expensive than the Amplatzer duct occluder (ADO). We also aimed to compare these two devices in terms of results. Between March 2005 and May 2012, 167 patients diagnosed with moderate-to-large PDA underwent transcatheter closure. ADO was used in 56 (33.5%) patients with a mean age of 8.1 ± 11.9 years (3.6 months-56 years), whereas CDO was used in 111 (66.5%) patients with a mean age of 12.6 ± 14.6 years (4.8 months-63 years). The narrowest PDA diameter, the used device diameter, procedure time, fluoroscopy time, and residual shunt rates were similar between the two groups. Procedural success rate was 100% in both groups. Although the residual shunt rate was higher in the CDO group immediately after the procedure, the difference was not statistically significant (12.6 vs. 8.9%; P = 0.3). There was no statistically significant difference between groups at discharge and during follow-up. No deaths occurred in any of the groups, and there were no differences in complication rates during the short- and mid-term follow-up periods (CDO 7/111 vs. ADO 5/56; P = 0.5 π). The CDO can be used for PDA closure because of its safety, effectiveness, and simplicity in use. It is available in bigger sizes and can be used in patients with large defects. According to our short- and mid-term findings, the results it yields are similar to those of the ADO; thus, it may be the preferred choice owing to its low cost and large size variability. Copyright © 2013 Wiley Periodicals, Inc.
Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers
Jiang, Tianyong; Kong, Qingzhao; Wang, Wenxi; Huo, Linsheng; Song, Gangbing
2016-01-01
A post-tensioning tendon duct filled with grout can effectively prevent corrosion of the reinforcement, maintain bonding behavior between the reinforcement and concrete, and enhance the load bearing capacity of concrete structures. In practice, grouting of the post-tensioning tendon ducts always causes quality problems, which may reduce structural integrity and service life, and even cause accidents. However, monitoring of the grouting compactness is still a challenge due to the invisibility of the grout in the duct during the grouting process. This paper presents a stress wave-based active sensing approach using piezoceramic transducers to monitor the grouting compactness in real time. A segment of a commercial tendon duct was used as research object in this study. One lead zirconate titanate (PZT) piezoceramic transducer with marble protection, called a smart aggregate (SA), was bonded on the tendon and installed in the tendon duct. Two PZT patch sensors were mounted on the top outside surface of the duct, and one PZT patch sensor was bonded on the bottom outside surface of the tendon duct. In the active sensing approach, the SA was used as an actuator to generate a stress wave and the PZT sensors were utilized to detect the wave response. Cement or grout in the duct functions as a wave conduit, which can propagate the stress wave. If the cement or grout is not fully filled in the tendon duct, the top PZT sensors cannot receive much stress wave energy. The experimental procedures simulated four stages during the grout pouring process, which includes empty status, half grouting, 90% grouting, and full grouting of the duct. Experimental results show that the bottom PZT sensor can detect the signal when the grout level increases towards 50%, when a conduit between the SA and PZT sensor is formed. The top PZT sensors cannot receive any signal until the grout process is completely finished. The wavelet packet-based energy analysis was adopted in this research to compute the total signal energy received by PZT sensors. Experimental results show that the energy levels of the PZT sensors can reflect the degree of grouting compactness in the duct. The proposed method has the potential to be implemented to monitor the tendon duct grouting compactness of the reinforced concrete structures with post tensioning. PMID:27556470
Subsonic Flows through S-Ducts with Flow Control
NASA Astrophysics Data System (ADS)
Chen, Yi
An inlet duct of an aircraft connects the air intake mounted on the fuselage to the engine within the aircraft body. The ideal outflow quality of the duct is steady, uniform and of high total pressure. Recently compact S-shaped inlet ducts are drawing more attention in the design of UAVs with short propulsion system. Compact ducts usually involve strong streamwise adverse pressure gradient and transverse secondary flow, leading to large-scale harmful vortical structures in the outflow. To improve the outflow quality modern flow control techniques have to be applied. Before designing successful flow control methods a solid understanding of the baseline flow field with the duct is crucial. In this work the fundamental mechanism of how the three dimensional flow topology evolves when the relevant parameters such as the duct geometry and boundary layer thickness are varied, is studied carefully. Two distinct secondary-flow patterns are identified. For the first time the sensitivity of the flow topology to the inflow boundary layer thickness in long ducts is clearly addressed. The interaction between the transverse motion induced by the transverse pressure gradient and the streamwise separation is revealed as the crucial reason for the various flow patterns existing in short ducts. A non-symmetric flow pattern is identified for the first time in both experiments and simulations in short ducts in which the intensity of the streamwise separation and the transverse invasion are in the same order of magnitude. A theory of energy accumulation and solution bifurcation is used to give a reasonable explanation for this non-symmetry. After gaining the knowledge of where and how the harmful vortical structures are generated several flow control techniques are tested to achieve a better outflow quality. The analysis of the flow control cases also provides a deeper insight into the behavior of the three-dimensional flow within the ducts. The conventional separation control method of Coanda injection is proved to be less effective in short ducts dominated by strong three-dimensional effects. Besides, the injection enhances the energy accumulation in duct with the asymmetric pattern and leads to the amplification of the asymmetry. Vortex generator jets are applied to generate spanwise near-wall motions opposing the transverse invasion and to break the strong interaction between the invasion and the separation. Symmetry is regained successfully.
Ikegami, T; Taniguchi, M; Singer, A W; Brooker, M J; Yarrington, J; Placke, M E; Lee, K P
2000-05-01
One hundred and forty male and 140 female rats were divided into 1 control and 3 test groups of 35 rats each, per sex, and exposed by whole-body inhalation to test compound at target concentrations of 0, 1 mg/m(3) (1700 fibers/cm(3), 123 WHO fibers/cm(3)), 10 mg/m(3) (5900 fibers/cm(3), 952 WHO fibers/cm(3)), and 100 mg/m(3) (112,700 fibers/cm(3), 7440 WHO fibers/cm(3)) for 6 h/day, 5 days/wk for 13 wk. Ten rats from each group were killed after 13 wk of exposure and 13 wk of recovery, respectively, for histopathological evaluation. The other 15 rats from each group were killed to study lung clearance after 91 days of exposure, and approximately 1.5 and 3 mo of recovery following the end of the 13 wk of exposure. The mean fiber length of the chamber atmosphere was 2.8, 2.7, and 2.8 microm, while the mean fiber width was 0.48, 0.48, and 0.45 microm for the 1-, 10-, and 100-mg/m(3) chambers, respectively. In the 1-mg/m(3) (123 WHO fibers/cm(3)) exposure group, inhaled particles were mostly retained in a few fiber-laden alveolar macrophages (AMs) within the alveoli adjacent to alveolar ducts without any adverse tissue response throughout 13 wk of exposure and following 13 wk of recovery. This exposure concentration was considered to be a no-observable-adverse-effect level (NOAEL), since the alveoli containing fiber-laden AMs preserved normal structure. After 13 wk of exposure to 10 mg/m(3) (952 WHO fibers/cm(3)), fiber-laden AMs were mainly retained at the alveoli adjacent to the alveolar ducts. Infrequently, slight fibrotic thickening was observed in the alveolar ducts and adjoining alveoli, with proliferating fibroblasts and hyperplastic Type II pneumocytes, and microgranulomas. Occasionally, trace amounts of collagenous material were deposited in the thickened alveolar ducts and adjoining alveolar walls. In addition, minimal alveolar bronchiolarization was occasionally found in the alveoli adjacent to the terminal bronchioles. The peribronchial lymphoid tissue and thymic lymph nodes contained migrated fiber-laden AMs. After 13 wk of recovery, fiber-laden AMs had mostly disappeared from alveoli located in the peripheral acini, but they localized in the alveolar ducts region, suggesting there was active lung clearance of fibers by the AMs via airways. Thickened alveolar ducts and adjacent alveoli were decreased in thickness, a reversible change manifested by reduction of proliferating Type II pneumocytes and fibroblasts. Collagenized fibrosis was slightly more pronounced in the thickened alveolar ducts and adjoining alveoli. The lung response following 13 wk of exposure to 100 mg/m(3) (7440 WHO fibers/cm(3)) and after 13 wk of recovery was similar to those findings of the 952 WHO fibers/cm(3) group but more pronounced, demonstrating a clear concentration-related response. Alveolar ducts and adjoining alveolar walls in the central acini were irregularly thickened with more frequent evidence of minimal collagenized fibrosis. The lung burden and clearance of fibers were estimated by measuring the total content of titanium (Ti) in the lungs, but high variability of Ti content in control and exposed groups prevented meaningful lung clearance analysis.
Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beach, Robert; Prahl, Duncan; Lange, Rich
2013-12-01
IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away frommore » the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.« less
Cho, Jai Young; Jaeger, Allison R; Sanford, Dominic E; Fields, Ryan C; Strasberg, Steven M
2015-09-01
A standard format for reporting observational surgical studies does not exist. This creates difficulties in comparing studies and in performing synthesis through systematic reviews and meta-analyses. This article proposes a method called "standard tabular reporting" and illustrates its use in a case series of bile duct reconstructions for biliary injuries occurring during cholecystectomy. A database dealing with biliary injuries was constructed in sections. Each section was designed to be turned into a table covering one element of the subject. Whenever possible, American College of Surgeons NSQIP "Classic Variables and Definitions" were used for forming sections and tables. However, most tables are original and specific to biliary injury. The database was populated from clinical records of patients who sustained a biliary injury during cholecystectomy. Tables were created dealing with the following subjects: demographics, index operation, presentation, classification of injury, preoperative risk assessment, preoperative laboratory values, operative repair technique, postoperative complications, and long-term outcomes. Between 1997 and 2013, 122 primary bile duct reconstructions were performed, with 1 mortality and 47 complications. Good long-term results were obtained in 113 (92.6%) patients. No secondary surgical reconstructions have been needed. Presentation of data in a standard format would facilitate comparison and synthesis of observational studies on the same subject. The biliary reconstructive methods used resulted in very satisfactory outcomes. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Resin duct characteristics in the wood of fire-scarred North American conifers
Estelle Arbellay; Markus Stoffel; Elaine K. Sutherland; Kevin T. Smith; Donald A. Falk
2013-01-01
Traumatic resin ducts form in xylem and phloem tissue of conifers in response to abiotic wounding, fungal invasion, and insect attack. Little is known about resin duct characteristics in the wood of fire-scarred trees. The aim of this study is to quantify changes in traits of both axial and radial resin ducts, along with those of associated epithelial cells and...
HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant
2016-09-01
material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is
NASA Astrophysics Data System (ADS)
Mironov, M. A.
2011-11-01
A method of allowing for the spatial sound field structure in designing the sound-absorbing structures for turbojet aircraft engine ducts is proposed. The acoustic impedance of a duct should be chosen so as to prevent the reflection of the primary sound field, which is generated by the sound source in the absence of the duct, from the duct walls.
BMS-247550 in Treating Patients With Liver or Gallbladder Cancer
2014-05-13
Adult Primary Cholangiocellular Carcinoma; Adult Primary Hepatocellular Carcinoma; Advanced Adult Primary Liver Cancer; Cholangiocarcinoma of the Extrahepatic Bile Duct; Cholangiocarcinoma of the Gallbladder; Localized Extrahepatic Bile Duct Cancer; Localized Gallbladder Cancer; Localized Resectable Adult Primary Liver Cancer; Localized Unresectable Adult Primary Liver Cancer; Recurrent Adult Primary Liver Cancer; Recurrent Extrahepatic Bile Duct Cancer; Recurrent Gallbladder Cancer; Unresectable Extrahepatic Bile Duct Cancer; Unresectable Gallbladder Cancer
Cooling air recycling for gas turbine transition duct end frame and related method
Cromer, Robert Harold; Bechtel, William Theodore; Sutcu, Maz
2002-01-01
A method of cooling a transition duct end frame in a gas turbine includes the steps of a) directing cooling air into the end frame from a region external of the transition duct and the impingement cooling sleeve; and b) redirecting the cooling air from the end frame into the annulus between the transition duct and the impingement cooling sleeve.
Molecular characteristics and alterations during early development of the human vagina
Fritsch, Helga; Richter, Elisabeth; Adam, Nadia
2012-01-01
Unresolved questions remain concerning the derivation of the vagina with respect to the relative contributions from the Müllerian ducts, the urogenital sinus, and the Wolffian ducts. Recent molecular and cellular studies in rodents have opened up a large gap between the level of understanding of vaginal development in mice and understanding of human vaginal development, which is based on histology. To compare the findings in mice with human vaginal development and to address this gap, we analysed molecular characteristics of the urogenital sinus, Wolffian ducts, and Müllerian ducts in 8–14-week-old human specimens using immunohistochemical methods. The monoclonal antibodies used were directed against cytokeratin (CK) 14, CK19, vimentin, laminin, p63, E-cadherin, caspase-3, Ki67, HOX A13, and BMP-4. The immunohistochemical analysis revealed that, during weeks 8–9, the epithelium of the Müllerian ducts became positive for p63 as p63-positive cells that originated from the sinus epithelium reached the caudal tip of the fused Müllerian ducts via the Wolffian ducts. The lumen of the fused Müllerian ducts was closed by an epithelial plug that contained both vimentin-positive and vimentin-negative cells. Subsequently, the resulting epithelial tube enlarged by proliferation of basal p63-positive cells. The first signs of squamous differentiation were detected during week 14, with the appearance of CK14-positive cells. According to our results, all three components, namely, the urogenital sinus, Wolffian ducts, and Müllerian ducts, interacted during the formation of the human vagina. The sinus epithelium provided p63-positive cells, the Wollfian ducts acted as a ‘transporter’, and the Müllerian ducts contributed the guiding structure for the vaginal anlagen. Epithelial differentiation began at the end of the period studied and extended in a caudo-cranial direction. The present study is one of the first to provide up-to-date molecular correlates for human vaginal development that can be compared with the results of cell biological studies in rodents. PMID:22256858
NASA Astrophysics Data System (ADS)
Leung, R. C. K.; So, R. M. C.; Tang, S. K.; Wang, X. Q.
2011-07-01
In-duct devices are commonly installed in flow ducts for various flow management purposes. The structural construction of these devices indispensably creates disruption to smooth flow through duct passages so they exist as structural discontinuities in duct flow. The presence of these discontinuities provides additional possibility of noise generation. In real practice, in-duct devices do not exist alone in any duct system. Even though each in-duct device would generate its own noise, it might be possible that these devices could be properly arranged so as to strengthen the interference between individual noise; thus giving rise to an overall reduction of noise radiation in the in-duct far field. This concept of passive noise control is investigated by considering different configurations of two structural discontinuities of simple form (i.e., a cavity) in tandem in an unconfined flow and in opposing setting within a flow duct. It is known that noise generated by a cavity in unconfined domain (unconfined cavity) is strongly dependent on flow-resonant behavior within the cavity so the interference it produces is merely aeroacoustic. The objective of the present study is to verify the concept of passive noise reduction through enhancement of aeroacoustic interference due to two cavities by considering laminar flow only. A two-dimensional approach is adopted for the direct aeroacoustic calculations using a direct numerical simulation (DNS) technique. The position and geometries of the cavities and the Mach number are varied; the resultant aeroacoustic behavior and acoustic power are calculated. The numerical results are compared with a single cavity case to highlight the effect of introducing additional cavities to the aeroacoustic problem. Resonant flow oscillations occur when two unconfined cavities are very close and the associated acoustic field is very intense with no noise reduction possible. However, for duct aeroacoustics, it is found that a 7.9 db reduction of acoustic power in the downstream side of the duct or a total reduction of ˜6 db is possible with opposing cavities having an offset of half a cavity length. In addition, the reduction is shown to be free from lock-on with trapped modes of the ducts with cavities.
Development of an Experimental Rig for Investigation of Higher Order Modes in Ducts
NASA Technical Reports Server (NTRS)
Gerhold, Carl H.; Cabell, Randolph H.; Brown, Martha C.
2006-01-01
Continued progress to reduce fan noise emission from high bypass ratio engine ducts in aircraft increasingly relies on accurate description of the sound propagation in the duct. A project has been undertaken at NASA Langley Research Center to investigate the propagation of higher order modes in ducts with flow. This is a two-pronged approach, including development of analytic models (the subject of a separate paper) and installation of a laboratory-quality test rig. The purposes of the rig are to validate the analytical models and to evaluate novel duct acoustic liner concepts, both passive and active. The dimensions of the experimental rig test section scale to between 25% and 50% of the aft bypass ducts of most modern engines. The duct is of rectangular cross section so as to provide flexibility to design and fabricate test duct liner samples. The test section can accommodate flow paths that are straight through or offset from inlet to discharge, the latter design allowing investigation of the effect of curvature on sound propagation and duct liner performance. The maximum air flow rate through the duct is Mach 0.3. Sound in the duct is generated by an array of 16 high-intensity acoustic drivers. The signals to the loudspeaker array are generated by a multi-input/multi-output feedforward control system that has been developed for this project. The sound is sampled by arrays of flush-mounted microphones and a modal decomposition is performed at the frequency of sound generation. The data acquisition system consists of two arrays of flush-mounted microphones, one upstream of the test section and one downstream. The data are used to determine parameters such as the overall insertion loss of the test section treatment as well as the effect of the treatment on a modal basis such as mode scattering. The methodology used for modal decomposition is described, as is a description of the mode generation control system. Data are presented which demonstrate the performance of the controller to generate the desired mode while suppressing all other cut on modes in the duct.
NASA Technical Reports Server (NTRS)
Allgood, Daniel C.; Graham, Jason S.; Ahuja, Vineet; Hosangadi, Ashvin
2008-01-01
Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.
The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...