Variability of the QuantiFERON®-TB gold in-tube test using automated and manual methods.
Whitworth, William C; Goodwin, Donald J; Racster, Laura; West, Kevin B; Chuke, Stella O; Daniels, Laura J; Campbell, Brandon H; Bohanon, Jamaria; Jaffar, Atheer T; Drane, Wanzer; Sjoberg, Paul A; Mazurek, Gerald H
2014-01-01
The QuantiFERON®-TB Gold In-Tube test (QFT-GIT) detects Mycobacterium tuberculosis (Mtb) infection by measuring release of interferon gamma (IFN-γ) when T-cells (in heparinized whole blood) are stimulated with specific Mtb antigens. The amount of IFN-γ is determined by enzyme-linked immunosorbent assay (ELISA). Automation of the ELISA method may reduce variability. To assess the impact of ELISA automation, we compared QFT-GIT results and variability when ELISAs were performed manually and with automation. Blood was collected into two sets of QFT-GIT tubes and processed at the same time. For each set, IFN-γ was measured in automated and manual ELISAs. Variability in interpretations and IFN-γ measurements was assessed between automated (A1 vs. A2) and manual (M1 vs. M2) ELISAs. Variability in IFN-γ measurements was also assessed on separate groups stratified by the mean of the four ELISAs. Subjects (N = 146) had two automated and two manual ELISAs completed. Overall, interpretations were discordant for 16 (11%) subjects. Excluding one subject with indeterminate results, 7 (4.8%) subjects had discordant automated interpretations and 10 (6.9%) subjects had discordant manual interpretations (p = 0.17). Quantitative variability was not uniform; within-subject variability was greater with higher IFN-γ measurements and with manual ELISAs. For subjects with mean TB Responses ±0.25 IU/mL of the 0.35 IU/mL cutoff, the within-subject standard deviation for two manual tests was 0.27 (CI95 = 0.22-0.37) IU/mL vs. 0.09 (CI95 = 0.07-0.12) IU/mL for two automated tests. QFT-GIT ELISA automation may reduce variability near the test cutoff. Methodological differences should be considered when interpreting and using IFN-γ release assays (IGRAs).
John, Emily E; Nekouei, Omid; McClure, J T; Cameron, Marguerite; Keefe, Greg; Stryhn, Henrik
2018-06-01
Bulk tank milk (BTM) samples are used to determine the infection status and estimate dairy herd prevalence for bovine leukaemia virus (BLV) using an antibody ELISA assay. BLV ELISA variability between samples from the same herd or from different herds has not been investigated over long time periods. The main objective of this study was to determine the within-herd and between-herd variability of a BTM BLV ELISA assay over 1-month, 3-month, and 3-year sampling intervals. All of the Canadian Maritime region dairy herds (n = 523) that were active in 2013 and 2016 were included (83.9% and 86.9% of total herds in 2013 and 2016, respectively). BLV antibody levels were measured in three BTM samples collected at 1-month intervals in early 2013 as well as two BTM samples collected over a 3-month interval in early 2016. Random-effects models, with fixed effects for sample replicate and province and random effects for herd, were used to estimate the variability between BTM samples from the same herd and between herds for 1-month, 3-month, and 3-year sampling intervals. The majority of variability of BTM BLV ELISA results was seen between herds (1-month, 6.792 ± 0.533; 3-month, 7.806 ± 0.652; 3-year, 6.222 ± 0.528). Unexplained variance between samples from the same herd, on square-root scale, was greatest for the 3-year (0.976 ± 0.104), followed by the 1-month (0.611 ± 0.035) then the 3-month (0.557 ± 0.071) intervals. Variability of BTM antibody levels within the same herd was present but was much smaller than the variability between herds, and was greatest for the 3-year sampling interval. The 3-month sampling interval resulted in the least variability and is appropriate to use for estimating the baseline level of within-herd prevalence for BLV control programs. Knowledge of the baseline variability and within-herd prevalence can help to determine effectiveness of control programs when BTM sampling is repeated at longer intervals. Copyright © 2018 Elsevier B.V. All rights reserved.
Haserodt, Sarah; Aytekin, Metin; Dweik, Raed A
2011-02-01
Hyaluronan (HA) is a glycosaminoglycan found in the extracellular matrix and ranges from several thousand to millions of daltons in size. HA has importance in various pathological conditions and is known to be elevated in several diseases. Three commonly used, commercially available HA enzyme-linked immunosorbent assay (ELISA)-like assays (from Corgenix, Echelon and R&D) were compared on the basis of accuracy, sample variability and ability to measure a range of HA sizes. The Corgenix HA ELISA-like assay displayed the lowest intra-assay variability [coefficient of variation (CV) = 11.7 ± 3.6%], followed by R&D (CV = 12.3 ± 4.6%) and Echelon (CV = 18.9 ± 9.2%). Interassay variability was also lowest for the Corgenix assay (CV = 6.0%), intermediate for the Echelon assay (9.5%) and highest for the R&D assay (CV = 34.1%). The high interassay variability seen for the R&D assay may have been due to the effect of dilution, since the dilution-independent interassay variability was 15.5%. The concentration of the standard HA was overestimated by the Echelon assay by 85% and underestimated by the R&D and Corgenix assays by 34 and 32%, respectively. The Echelon HA ELISA-like assay was the most effective at measuring all sizes of HA tested (2 MDa and 132, 66 and 6.4 kDa), whereas the Corgenix and R&D assays were unable to detect 6.4 kDa HA. These findings suggest that the Echelon HA ELISA-like assay is better suited for size-sensitive HA measurements but has a relatively high variability. The Corgenix and R&D HA ELISA-like assays have low variability and high accuracy but are not suitable for detecting low-molecular-weight HA.
Cloning and analysis of the gene for a major surface antigen of Mycoplasma gallisepticum.
Spencer, Denise L; Kurth, Kathy Toohey; Menon, Sreekumar A; VanDyk, Tina; Minion, F Chris
2002-01-01
Myplasma gallisepticum infects a wide variety of gallineaceous birds including chickens, turkeys, and pheasants. Infection occurs both horizontally and vertically. Thus, control of the spread of M. gallisepticum to noninfected flocks is difficult. Continual monitoring is necessary to identify infected flocks even under the most stringent infectious control practices. Monitoring, however, is usually performed by measuring hemagglutination activity (HA) in serum, an insensitive and variable test. Variability in the HA test arises differences in agglutination antigen, changes in antigenic profiles of the M. gallisepticum strain, and variability in reading the agglutination reaction. Enzyme-linked immunosorbent assays (ELISAs) are the preferred method of testing because of the ease in obtaining sera and the sensitivity and reproducibility of the assays, but the ELISA suffers from a lack of standardization in the test antigen. The ELISA test will be more easily accepted once the test antigen has been standardized. To this end, we have identified, cloned, and characterized the gene for an antigen that has potential as a species-specific antigen for M. gallisepticum The gene codes for a 75-kD protein, P75, that is recognized during natural infections. Recombinant P75 is not recognized in immunoblots by convalescent sera produced in chickens infected with Mycoplasma synoviae, Mycoplasma gallinarum, and Mycoplasma gallinaceum or in turkeys infected with Mycoplasma meleagridis.
2016-03-01
performance in an enzyme-linked immunosorbent assay ( ELISA ), with little regard for quantification of the full spectrum of variables affecting antibody...Program (ATP) Quality MS2 coat protein (MS2CP) Enzyme-linked immunosorbent assay ( ELISA ) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...5 2.7 ELISA ................................................................................................................5
Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.
1998-01-01
Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.
Lee, Eui Hyung; Kim, Yeon Hee; Kim, Sinyoung; Kim, Song-ee
2012-01-01
Background Bullous pemphigoid (BP) is an autoimmune subepidermal bullous disease associated with autoantibodies against BP180 and BP230. Enzyme-linked immunosorbent assay (ELISA) is a sensitive tool for the detection of immunoglobulin G (IgG) anti-BP180 and anti-BP230 autoantibodies. Objective The aim of this study was to evaluate the usefulness of ELISA for diagnosing and monitoring the disease activity of BP. Methods We evaluated serum IgG levels of anti-BP180 and anti-BP230 autoantibodies in 47 BP patients, 16 epidermolysis bullosa aquisita patients, and 15 healthy volunteers using ELISA. Through retrospective review of the medical records, the clinical characteristics of BP including disease activity, duration, pruritus severity and peripheral blood eosinophil counts were assessed. Results The sensitivity of BP180 ELISA was 97.9%, BP230 ELISA 72.3%, and a combination of the two was 100%. The specificity of BP180 ELISA was 90.3%, BP230 ELISA 100%, and a combination of the two was 90.3%. BP180 ELISA scores showed strong associations with disease activity, pruritus severity, peripheral blood eosinophil counts, and disease duration, whereas BP230 ELISA scores did not. Conclusion BP180 and BP230 ELISAs are highly sensitive methods for the diagnosis of BP, and BP180 ELISA, in particular, is a sensitive tool for monitoring the disease activity of BP. PMID:22363155
Xu, Chongxin; Zhang, Cunzheng; Zhong, Jianfeng; Hu, Hui; Luo, Shimin; Liu, Xiaoqin; Zhang, Xiao; Liu, Yuan; Liu, Xianjin
2017-07-26
In the present study, a Cry1F-immunized rabbit phage display library (6.96 × 10 8 cfu/mL) was constructed for selecting high activity of anti-Cry1F toxin single-chain antibody (a single-chain variable fragment, scFv) by biopanning. A total of 16 positive monoclonal phage scFv's were obtained after 4 rounds of panning, which were identified by enzyme-linked immunosorbent assay (ELISA), polymerized chain reaction, and DNA sequencing. The most positive phage scFv (named RF4) was expressed in Escherichia coli HB2151, and a soluble protein of approximately 30 kDa was purified with sodium dodecyl sulfate-polyacrylamide gel electrophoresis. An indirect competitive ELISA (IC-ELISA) was established on the basis of purified soluble RF4-scFv for Cry1F toxin. It indicated the 50% inhibition of the control (IC 50 ) was 11.56 ng/mL and the detection limit (IC 10 ) was 0.18 ng/mL and showed weak cross-reactivities for Cry1Ab (2.8%), Cry1Ac (1.3%), and Cry1B, Cry1C, Cry1Ie, and Cry2A (less than 0.1%). It was found that IC-ELISA detected Cry1F toxin spiked in rice, wheat, corn, and soil samples with good accuracy, stability, and repeatability. The recoveries were in the range of 80.2-99.6%, and the coefficients of variation were in the range of 2.5-10.0%. These results showed that IC-ELISA based on scFv from the immunized rabbit phage display library was promising for specific detection of Cry1F toxin in agroproducts and environmental samples.
Sridevi, N. V.; Shukra, A. M.; Neelakantam, B.; Anilkumar, J.; Madhanmohan, M.; Rajan, S.; Dev Chandran
2014-01-01
Recombinant antibody fragments like single chain variable fragments (scFvs) represent an attractive yet powerful alternative to immunoglobulins and hold great potential in the development of clinical diagnostic/therapeutic reagents. Structurally, scFvs are the smallest antibody fragments capable of retaining the antigen-binding capacity of whole antibodies and are composed of an immunoglobulin (Ig) variable light (VL) and variable heavy (VH) chain joined by a flexible polypeptide linker. In the present study, we constructed a scFv against bovine IgA from a hybridoma cell line IL-A71 that secretes a monoclonal antibody against bovine IgA using recombinant DNA technology. The scFv was expressed in Escherichia coli and purified using immobilized metal affinity chromatography (IMAC). The binding activity and specificity of the scFv was established by its non-reactivity toward other classes of immunoglobulins as determined by enzyme-linked immunosorbent assay (ELISA) and immunoblot analysis. Kinetic measurement of the scFv indicated that the recombinant antibody fragment had an affinity in picomolar range toward purified IgA. Furthermore, the scFv was used to develop a sensitive ELISA for the detection of foot and mouth disease virus (FMDV) carrier animals. PMID:24678404
Barregard, Lars; Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J; Weimann, Allan; Poulsen, Henrik E; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J; Santella, Regina M; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen; Cooke, Marcus S
2013-06-20
Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.
Denburg, Michelle R.; Hoofnagle, Andrew N.; Sayed, Samir; Gupta, Jayanta; de Boer, Ian H.; Appel, Lawrence J.; Durazo-Arvizu, Ramon; Whitehead, Krista; Feldman, Harold I.; Leonard, Mary B.
2016-01-01
Studies using vitamin D-binding protein (DBP) concentrations to estimate free and bioavailable vitamin D have increased dramatically in recent years. Combinations of two single-nucleotide polymorphisms produce three major DBP isoforms (Gc1f, Gc1s and Gc2). A recent study showed that DBP concentrations quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) did not differ by race, while a widely used monoclonal ELISA quantified DBP differentially by isoform, yielding significantly lower DBP concentrations in black versus white individuals. We compared measurements of serum DBP using a monoclonal ELISA, a polyclonal ELISA, and LC-MS/MS in 125 participants in the Chronic Renal Insufficiency Cohort. Serum free and bioavailable 25OHD were calculated based on DBP concentrations from these three assays in homozygous participants, and race differences were compared. We confirmed that the monoclonal ELISA quantifies DBP differentially by isoform and demonstrated that the polyclonal ELISA is not subject to this bias. While ≤9% of the variability in DBP concentrations quantified using either LC-MS/MS or the polyclonal ELISA was explained by genotype, 85% of the variability in the monoclonal ELISA-based measures was explained by genotypes. DBP concentrations measured by the monoclonal ELISA were disproportionately lower than LC-MS/MS-based results for Gc1f homozygotes [median difference −67%; interquartile range (IQR) −71%, −64%], 95% of whom were black. In contrast, the polyclonal ELISA yielded consistently and similarly higher measurements of DBP than LC-MS/MS, irrespective of genotype, with a median percent difference of +50% [IQR +33%, +65%]. Contrary to findings using the monoclonal ELISA, DBP concentrations did not differ by race, and free and bioavailable 25OHD were significantly lower in black versus white participants based on both the polyclonal ELISA and LC-MS/MS, consistent with their lower total 25OHD. Future studies of DBP and free or bioavailable vitamin D metabolites should employ DBP assays that are not biased by DBP genotype. PMID:27250744
Enzyme-linked immunosorbent assay for detection of antibodies to Epstein-Barr virus antigens.
Voevodin, A F; Pácsa, A S
1983-01-01
Enzyme-Linked Immunosorbent Assay (ELISA) was standardized for measurement of antibody activity of reference human and baboon (Papio hamadryas) sera to soluble Epstein-Barr virus (EBV) antigens. A comparison with the immunofluorescent (IF) method showed that ELISA detects antibody specifically and sensitivity. In ELISA, Herpesvirus Papio (HVP) nuclear antigen (HUPNA) positive baboon serum reacted with EBV nuclear antigen (EBNA), as a further indication of the antigenic similarity between HVP and EBV. Forty-two baboon sera were tested with EBV antigens in both ELISA and IF test. The results showed an agreement between the two methods and also that by the use of EBV antigens, ELISA measures anti-HVP activity of baboon sera. ELISA did not reveal significant difference in antibody activity of 23 baboons with lymphoma and that of 24 healthy baboons. Results provide further data that ELISA can be used effectively in the field of EBV serology.
Thibodeaux, Brett A.; Panella, Amanda N.; Roehrig, John T.
2010-01-01
Diagnosis of human arboviral infections relies heavily on serological techniques such as the immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and the indirect IgG ELISA. Broad application of these assays is hindered by the lack of standardized positive human control sera that react with a wide variety of flaviviruses (e.g., dengue, West Nile, yellow fever, Japanese encephalitis, Saint Louis encephalitis, and Powassan viruses), or alphaviruses (e.g., Eastern equine encephalitis, Western equine encephalitis, Venezuelan equine encephalitis, and chikungunya viruses) that can cause human disease. We have created human-murine chimeric monoclonal antibodies (cMAbs) by combining the variable regions of flavivirus (6B6C-1) or alphavirus (1A4B-6) broadly cross-reactive murine MAbs (mMAbs) with the constant region of human IgG1. These cMAbs may be used as standardized reagents capable of replacing human infection-immune-positive control sera in indirect IgG ELISA for diagnosis of all human flaviviral or alphaviral infections. The IgG cMAbs secreted from plasmid-transformed Sp2/0-Ag14 cells had serological activity identical to that of the parent mMAbs, as measured by ELISA using multiple flaviviruses or alphaviruses. PMID:20739503
Thibodeaux, Brett A; Panella, Amanda N; Roehrig, John T
2010-10-01
Diagnosis of human arboviral infections relies heavily on serological techniques such as the immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and the indirect IgG ELISA. Broad application of these assays is hindered by the lack of standardized positive human control sera that react with a wide variety of flaviviruses (e.g., dengue, West Nile, yellow fever, Japanese encephalitis, Saint Louis encephalitis, and Powassan viruses), or alphaviruses (e.g., Eastern equine encephalitis, Western equine encephalitis, Venezuelan equine encephalitis, and chikungunya viruses) that can cause human disease. We have created human-murine chimeric monoclonal antibodies (cMAbs) by combining the variable regions of flavivirus (6B6C-1) or alphavirus (1A4B-6) broadly cross-reactive murine MAbs (mMAbs) with the constant region of human IgG1. These cMAbs may be used as standardized reagents capable of replacing human infection-immune-positive control sera in indirect IgG ELISA for diagnosis of all human flaviviral or alphaviral infections. The IgG cMAbs secreted from plasmid-transformed Sp2/0-Ag14 cells had serological activity identical to that of the parent mMAbs, as measured by ELISA using multiple flaviviruses or alphaviruses.
Diagnostic Accuracy of Antigen 5-Based ELISAs for Human Cystic Echinococcosis
Pagnozzi, Daniela; Addis, Maria Filippa; Biosa, Grazia; Roggio, Anna Maria; Tedde, Vittorio; Mariconti, Mara; Tamarozzi, Francesca; Meroni, Valeria; Masu, Gabriella; Masala, Giovanna; Brunetti, Enrico; Uzzau, Sergio
2016-01-01
Background Clinical diagnosis and follow up of cystic echinococcosis (CE) are based on imaging complemented by serology. Several immunodiagnostic tests are commercially available, but the development of new tools is still needed to overcome the lack of standardization of the target antigen, generally consisting of a crude extract of Echinococcus granulosus hydatid cyst fluid. In a previous work, we described a chromatographic method for the preparation of a highly enriched Antigen 5 fraction from hydatid cyst fluid. The high reactivity of patient sera against this preparation prompted us to evaluate further this antigen for the serodiagnosis of CE on a larger cohort of samples. Methodology/Principal Findings A total of 327 sera from CE patients with heterogeneous conditions for cyst stage, cyst number, organ localization, drug therapy, and surgical intervention, together with 253 sera from healthy controls, were first analyzed by an ELISA based on the Ag5 preparation in two different experimental setups and, in parallel, by a commercial ELISA routinely used in clinical laboratories for CE serodiagnosis. The Ag5 ELISAs revealed different sensitivity (88.3% vs 95.3%) without significant differences in specificity (94.1% vs 92.5%), for the two setups, respectively. Moreover, possible relationships between the Ag5 ELISA absorbance results and clinical variables were investigated. Chi squared test, bivariate logistic regression and multiple regression analyses highlighted differences in the serology reactivity according to pharmacological treatment, cyst activity, and cyst number. Conclusions/Significance The two Ag5 ELISAs revealed different performances depending on the setup. The good diagnostic sensitivity and the high reliability of the Ag5 preparation method make this antigen a promising candidate for the serodiagnosis of CE. Further studies will be needed to evaluate the ability of our test to provide useful information on specific CE clinical traits. PMID:27023205
Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J.; Weimann, Allan; Poulsen, Henrik E.; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D.; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B.; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T.; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J.; Santella, Regina M.; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen
2013-01-01
Abstract Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (rp 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391. PMID:23198723
Evaluating concentration estimation errors in ELISA microarray experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daly, Don S.; White, Amanda M.; Varnum, Susan M.
Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to predict a protein concentration in a sample. Deploying ELISA in a microarray format permits simultaneous prediction of the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Evaluating prediction error is critical to interpreting biological significance and improving the ELISA microarray process. Evaluating prediction error must be automated to realize a reliable high-throughput ELISA microarray system. Methods: In this paper, we present a statistical method based on propagation of error to evaluate prediction errors in the ELISA microarray process. Althoughmore » propagation of error is central to this method, it is effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization and statistical diagnostics when evaluating ELISA microarray prediction errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of prediction errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error.« less
Joelsson, Daniel; Moravec, Phil; Troutman, Matthew; Pigeon, Joseph; DePhillips, Pete
2008-08-20
Transferring manual ELISAs to automated platforms requires optimizing the assays for each particular robotic platform. These optimization experiments are often time consuming and difficult to perform using a traditional one-factor-at-a-time strategy. In this manuscript we describe the development of an automated process using statistical design of experiments (DOE) to quickly optimize immunoassays for precision and robustness on the Tecan EVO liquid handler. By using fractional factorials and a split-plot design, five incubation time variables and four reagent concentration variables can be optimized in a short period of time.
Min, Won-Ki; Cho, Young-Jin; Park, Jun-Bock; Bae, Yi-Hyun; Kim, Eun-Jeong; Park, Kyungmoon; Park, Yong-Cheol; Seo, Jin-Ho
2010-01-01
Fumonisin B(1) (FMB(1)) is a food-born mycotoxin produced by Fusarium moniliforme. Monoclonal antibody against FMB(1) (anti-FMB(1) mAb) was produced in the hybridoma DV9, which was established from a BALB/c mouse immunized with bovine serum albumin conjugated FMB(1) (FMB(1)-BSA). A competitive direct enzyme-linked immunosorbent assay (ELISA) showed that anti-FMB(1) mAb has about 10 ppb of minimum FMB(1) detection concentration and 220 ppb of 50% inhibition concentration (IC(50)). Much lower cross-reactivity of anti-FMB(1) mAb on ochratoxin A, aflatoxin B(1) and deoxynivalenol provided that anti-FMB(1) mAb was specific for FMB(1). The gene coding single chain variable fragment against FMB(1) (anti-FMB(1) scFv) was cloned from the hybridoma DV9 and was expressed in recombinant Escherichia coli. Insoluble anti-FMB(1) scFv required optimization of its refolding condition, and hence functional scFv was obtained. By using indirect ELISA, about 12-fold lower binding activity of anti-FMB(1) scFv on FMB(1)-BSA was obtained in comparison with that of the parental mAb.
van Gorkom, T; Kremer, K; Voet, W; Notermans, D W; Vlaminckx, B J M; Sankatsing, S U C; Thijsen, S F T
2017-11-01
The diagnosis of Lyme borreliosis is challenging because of the often non-specific symptoms and persisting antibodies after infection. We investigated the diagnostic characteristics of two enzyme-linked immunosorbent assays (ELISAs) and an immunoblot for the detection of Borrelia-specific serum antibodies using different test strategies in individuals with and without antibiotic treatment for Lyme borreliosis. This retrospective study included healthy individuals, patients with active Lyme neuroborreliosis and patients treated for Lyme neuroborreliosis. Two ELISAs were compared: the C6 ELISA and the SERION ELISA. Equivocal and positive results were confirmed by immunoblot. We included 174 healthy individuals, of whom 27 (15.5%) were treated for Lyme borreliosis in the past, 36 patients were treated for Lyme neuroborreliosis and 27 patients had active Lyme neuroborreliosis. All the active Lyme neuroborreliosis patients were reactive in both ELISAs (100% sensitivity); less reactivity was seen in the other three groups (range 17.7% to 69.4%). The concordance between the ELISA results was high in active Lyme neuroborreliosis patients (26/27; 96.3%) and healthy individuals (131/147; 89.1%), but lower in treated healthy individuals (18/27; 66.7%) and treated Lyme neuroborreliosis patients (18/36; 50.0%) (p ≤ 0.005). This study showed that antibiotic treatment against Lyme borreliosis was strongly associated with discordant ELISA and test strategy results (odds ratio: 10.52; p < 0.001 and 9.98; p = 0.014, respectively) suggesting antibiotic treatment influences the pace at which the various antibodies directed to the different antigens used in both ELISAs wane. Among treated neuroborreliosis patients, the SERION ELISA stayed positive for a longer period after infection compared to the C6 ELISA. This should be taken into consideration when requesting and/or interpreting Lyme serology.
Haddon, D James; Diep, Vivian K; Price, Jordan V; Limb, Cindy; Utz, Paul J; Balboni, Imelda
2015-06-17
Pediatric systemic lupus erythematosus (pSLE) patients often initially present with more active and severe disease than adults, including a higher frequency of lupus nephritis. Specific autoantibodies, including anti-C1q, anti-DNA and anti-alpha-actinin, have been associated with kidney involvement in SLE, and DNA antibodies are capable of initiating early-stage lupus nephritis in severe combined immunodeficiency (SCID) mice. Over 100 different autoantibodies have been described in SLE patients, highlighting the need for comprehensive autoantibody profiling. Knowledge of the antibodies associated with pSLE and proliferative nephritis will increase the understanding of SLE pathogenesis, and may aid in monitoring patients for renal flare. We used autoantigen microarrays composed of 140 recombinant or purified antigens to compare the serum autoantibody profiles of new-onset pSLE patients (n = 45) to healthy controls (n = 17). We also compared pSLE patients with biopsy-confirmed class III or IV proliferative nephritis (n = 23) and without significant renal involvement (n = 18). We performed ELISA with selected autoantigens to validate the microarray findings. We created a multiple logistic regression model, based on the ELISA and clinical information, to predict whether a patient had proliferative nephritis, and used a validation cohort (n = 23) and longitudinal samples (88 patient visits) to test its accuracy. Fifty autoantibodies were at significantly higher levels in the sera of pSLE patients compared to healthy controls, including anti-B cell-activating factor (BAFF). High levels of anti-BAFF were associated with active disease. Thirteen serum autoantibodies were present at significantly higher levels in pSLE patients with proliferative nephritis than those without, and we confirmed five autoantigens (dsDNA, C1q, collagens IV and X and aggrecan) by ELISA. Our model, based on ELISA measurements and clinical variables, correctly identified patients with proliferative nephritis with 91 % accuracy. Autoantigen microarrays are an ideal platform for identifying autoantibodies associated with both pSLE and specific clinical manifestations of pSLE. Using multiple regression analysis to integrate autoantibody and clinical data permits accurate prediction of clinical manifestations with complex etiologies in pSLE.
Laborde, Juan M; Sguazza, Guillermo H; Fuentealba, Nadia A; Corva, Santiago G; Carbone, Cecilia; Galosi, Cecilia M
In this study we developed an indirect ELISA to detect antibodies against Minute Virus of Mice (MVM) using an antigen produced from BHK-21 cells infected with a prototype strain of the virus. The optimal antigen concentration and serum dilutions were established. In order to analyze variability in the laboratory, reproducibility and repeatability within and between plates were determined. Then, a panel of 460 sera from conventional facilities and previously classified as positive or negative by the indirect fluorescent antibody assay was analyzed. The cutoff value was determined by a receiver operating characteristic (ROC) curve. The results of the indirect ELISA were compared with those of the indirect fluorescent antibody assay. The ELISA assay showed 100% sensitivity and 99% specificity. ELISA is a useful tool to be developed in standard virology laboratories and can be used for screening animals faster than the traditional indirect fluorescent antibody assay. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku
2015-03-01
Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serological hallmark of ANCA-associated vasculitis (AAV). We evaluated the analytical and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) versus enzyme-linked immunosorbent assay (ELISA) for the detection of MPO-ANCA. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p < 0.0001). At the cutoff value of 3.5 U/ml, the CLEIA yielded positive test results for MPO-ANCA in 73 of the 242 sera (30.2%), while at the cutoff value of 20 U/ml, ELISA yielded positive test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-positive test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-positive result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, respectively, while those of the ELISA were 94.3% and 99.2%, respectively. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, respectively, while those of the ELISA were 94.3% and 73.6%, respectively. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA.
Wang, Linchuan; Tian, Xu-Dong; Yu, Yan; Chen, Wei
2018-04-01
The IGRA-ELISA and T-SPOT.TB are widely used in China. The aim of the study was to evaluate the performance of the two assays in diagnosis Mycobacterium tuberculosis infection. Of the 3727 patients in the study, 204 underwent testing using both the T-SPOT.TB and IGRA-ELISA, 1794 were tested using the T-SPOT.TB only, and 1729 were tested using the IGRA-ELISA only. The positive rate and consistency of the two assays were analyzed, and their sensitivity and specificity for diagnosing active tuberculosis were compared. There were no significant differences in the positive rate between the T-SPOT.TB test (25.8%) and IGRA-ELISA (28.6%), p = .065. The two assays were highly consistent, with a kappa value of 0.852 (p < .0001) and a total coincidence rate of 92.7%. For the diagnosis of active tuberculosis, the sensitivity and specificity values of the T-SPOT.TB test were 82.9% (107/129) and 78.6% (1309/1665), respectively, and those of IGRA-ELISA were 81.7% (94/115) and 75.2% (1214/1614), respectively. There were no significant differences in sensitivity (p > .05), but the specificity of the T-SPOT.TB test was slightly higher than that of IGRA-ELISA (p = .023). Both in terms of diagnosing M. tuberculosis infection and ruling out active tuberculosis, the performance of the IGRA-ELISA-a simple, almost labor-free assay that allows simultaneous processing of a very large number of samples-was well-matched with that of T-SPOT.TB test. However, IGRAs cannot be used as the only test to diagnose active tuberculosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio
2012-01-01
The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah
2016-08-30
The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.
Proksch, A L; Unterer, S; Speck, S; Truyen, U; Hartmann, K
2015-06-01
False negative faecal canine parvovirus (CPV) antigen ELISA results in dogs with CPV infection are common, but the factors that lead to these false negative results are still unknown. The aim of this study was to investigate whether dogs with a false negative faecal CPV antigen ELISA result have milder clinical signs and laboratory changes, a lower faecal virus load, higher faecal and serum CPV antibody titres and a faster recovery than dogs with a positive result. Eighty dogs with CPV infection, confirmed by the presence of clinical signs and a positive faecal CPV polymerase chain reaction (PCR), were assigned to two groups according to their faecal antigen ELISA result. Time until presentation, severity of symptoms, laboratory parameters, faecal virus load, faecal and serum antibody titres, and CPV sequencing data were compared between both groups. In 38/80 dogs that were hospitalised until recovery, the time to recovery, mortality, and the course of the disease were compared between dogs with positive and negative faecal antigen ELISA results. Of the 80 dogs included, 41 (51.3%) had a false negative faecal antigen ELISA result. ELISA-negative dogs had a significantly shorter time until presentation, lower frequency of defaecation, lower faecal virus load, and higher serum antibody concentrations than ELISA-positive dogs. Laboratory changes, CPV shedding, and outcomes were not associated with faecal antigen ELISA results. In conclusion, low faecal CPV load and antibodies binding to CPV antigen in faeces are likely to be important reasons for false negative faecal antigen ELISA results. Dogs with clinical signs of CPV infection should be retested by faecal PCR. Copyright © 2015 Elsevier Ltd. All rights reserved.
76 FR 4920 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
... appear to be distinct from each other. Available for licensing is a Plk1 ELISA assay using peptide... binding property, an easy and reliable ELISA assay has been developed to quantify Plk1 expression levels... sequence. ELISA assay to quantify Plk1 expression and kinase activity. Advantages: Rapid, highly sensitive...
Lobatón, Triana; Rodríguez-Moranta, Francisco; Lopez, Alicia; Sánchez, Elena; Rodríguez-Alonso, Lorena; Guardiola, Jordi
2013-04-01
Fecal calprotectin (FC) determined by the enzyme-linked immunosorbent assay (ELISA) test has been proposed as a promising biomarker of endoscopic activity in ulcerative colitis (UC). However, data on its accuracy in predicting endoscopic activity is scarce. Besides, FC determined by the quantitative-point-of-care test (FC-QPOCT) that provides rapid and individual results could optimize its use in clinical practice. The aims of our study were to evaluate the ability of FC to predict endoscopic activity according to the Mayo score in patients with UC when determined by FC-QPOCT and to compare it with the ELISA test (FC-ELISA). FC was determined simultaneously by FC-ELISA and FC-QPOCT in patients with UC undergoing colonoscopy. Clinical disease activity and endoscopy were assessed according to the Mayo score. Blood tests were taken to analyze serological biomarkers. A total of 146 colonoscopies were performed on 123 patients with UC. FC-QPOCT correlated more closely with the Mayo endoscopic subscore (Spearman's correlation coefficient rank r = 0.727, P < 0.001) than clinical activity (r = 0.636, P < 0.001), platelets (r = 0.381, P < 0.001), leucocytes (r = 0.300, P < 0.001), and C-reactive protein (r = 0.291, P = 0.002). The prediction of "endoscopic remission" (Mayo endoscopic subscore ≤1) with FC-QPOCT (280 µg/g) and FC-ELISA (250 µg/g) presented an area under the curve of 0.906 and 0.924, respectively. The interclass correlation index between both tests was 0.904 (95% confidence interval, 0.864-0.932; P < 0.001). FC determined by QPOCT was an accurate surrogate marker of "endoscopic remission" in UC and presented a good correlation with the FC-ELISA test.
Wang, Lei; Wang, Xiaoxia; Li, Ying; Cheng, Zeneng
2016-01-01
Etanercept is the first tumor necrosis factor inhibitor to be approved for rheumatic disease treatment. Its in vivo concentration is usually detected with commercial enzyme-linked immunosorbent assay (ELISA) kits; specifically, previous researchers have mostly used double-antibody sandwich ELISA technology. Double-antibody sandwich ELISA is employed to detect the total etanercept rather than biologically active etanercept, which is more relevant in terms of therapeutic drug monitoring. In this work, a sensitive ELISA that employed its antigen TNF-α to capture biologically active etanercept for concentration detection was established and validated for etanercept pharmacokinetic (PK) study in patients with ankylosing spondylitis (AS). The proposed assay was demonstrated to be precise and accurate over the linear range of 12.5-400pg/mL. The intra- and inter-assay relative standard deviation ranged from 3.9 to 12.2% and 6.2 to 11.1%, respectively, and recovery varied between 90.1 and 99.7%, confirming the assay's reliability. The effectiveness and accuracy of the assay was also validated according to quality samples containing etanercept with different TNF-α concentrations, and with plasma samples from patients with AS. To complete the study, both the proposed assay and double-antibody sandwich ELISA were applied to the PK study of etanercept in patients and compared. The multiple-dose results of both analytical methods were consistent, while the drug exposure of the first dose as-detected by the proposed assay was lower than that detected by double-antibody sandwich ELISA. In conclusion, the proposed ELISA was shown to provide more accurate concentration data for therapeutic drug monitoring in comparison to commercial ELISA kits. Copyright © 2015 Elsevier B.V. All rights reserved.
Development and Validation of Sandwich ELISA Microarrays with Minimal Assay Interference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gonzalez, Rachel M.; Servoss, Shannon; Crowley, Sheila A.
Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA’s ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of the multiplexed 24-assay system. We findmore » that non-specific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a “purified antigen”. We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals then within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.« less
Schraer, S.M.; Shaw, D.R.; Boyette, M.; Coupe, R.H.; Thurman, E.M.
2000-01-01
Enzyme-linked immunosorbent assay (ELISA) data from surface water reconnaissance were compared to data from samples analyzed by gas chromatography for the pesticide residues cyanazine (2-[[4-chloro-6-(ethylamino)-l,3,5-triazin-2-yl]amino]-2-methylpropanenitrile ) and metolachlor (2-chloro-N-(2-ethyl-6-methylphenyl)-N-(2-methoxy-1-methylethyl)acetamide). When ELISA analyses were duplicated, cyanazine and metolachlor detection was found to have highly reproducible results; adjusted R2s were 0.97 and 0.94, respectively. When ELISA results for cyanazine were regressed against gas chromatography results, the models effectively predicted cyanazine concentrations from ELISA analyses (adjusted R2s ranging from 0.76 to 0.81). The intercepts and slopes for these models were not different from 0 and 1, respectively. This indicates that cyanazine analysis by ELISA is expected to give the same results as analysis by gas chromatography. However, regressing ELISA analyses for metolachlor against gas chromatography data provided more variable results (adjusted R2s ranged from 0.67 to 0.94). Regression models for metolachlor analyses had two of three intercepts that were not different from 0. Slopes for all metolachlor regression models were significantly different from 1. This indicates that as metolachlor concentrations increase, ELISA will over- or under-estimate metolachlor concentration, depending on the method of comparison. ELISA can be effectively used to detect cyanazine and metolachlor in surface water samples. However, when detections of metolachlor have significant consequences or implications it may be necessary to use other analytical methods.
Jagarlamudi, Kiran Kumar; Moreau, Laura; Westberg, Sara; Rönnberg, Henrik; Eriksson, Staffan
2015-01-01
Thymidine kinase 1 (TK1) is a DNA precursor enzyme whose expression is closely correlated with cell proliferation and cell turnover. Sensitive serum TK1 activity assays have been used for monitoring and prognosis of hematological malignancies in both humans and dogs. Here we describe the development of a specific sandwich TK1-ELISA for the quantification of TK1 protein levels in sera from dogs with different malignancies. A combination of rabbit polyclonal anti-dog TK1 antibody and a mouse monoclonal anti-human TK1 antibody was used. Different concentrations of recombinant canine TK1 was used as standard. Clinical evaluation of the ELISA was done by using sera from 42 healthy dogs, 43 dogs with hematological tumors and 55 with solid tumors. An established [3H]-dThd phosphorylation assay was used to determine the TK1 activity levels in the same sera. The mean TK1 activities in dogs with hematological tumors were significantly higher than those found in healthy dogs. In agreement with earlier studies, no significant difference was observed in serum TK1 activities between healthy dogs and dogs with solid tumors. However, the mean TK1 protein levels determined by new TK1-ELISA were significantly higher not only in hematological tumors but also in solid tumors compared to healthy dogs (mean ± SD = 1.30 ± 1.16, 0.67 ± 0.55 and 0.27± 0.10 ng/mL, respectively). Moreover, TK1-ELISA had significantly higher ability to distinguish lymphoma cases from healthy based on receiver operating characteristic analyses (area under the curve, AUC, of 0.96) to that of the activity assay (AUC, 0.84). Furthermore, fluctuations in TK1 protein levels during the course of chemotherapy in dogs with lymphoma closely associated with clinical outcome. Overall, the TK1-ELISA showed significant linear correlation with the TK1 activity assay (r s = 0.6, p<0.0001). Thus, the new TK1-ELISA has sufficient sensitivity and specificity for routine clinical use in veterinary oncology. PMID:26366881
Lumor, Stephen E; Fredrickson, Neal R; Ronningen, Ian; Deen, Bronwyn D; Smith, Kenneth; Diez-Gonzalez, Francisco; Labuza, Theodore P
2012-06-01
This study was conducted to compare the identification of Shiga toxin 1 (Stx1) based on its specific biological activity and based on results of a commercial enzyme-linked immunosorbent assay (ELISA) kit. Stx1 was thermally treated for various periods in phosphate-buffered saline, milk, and orange juice. The residual Stx1 concentration was determined with the commercial ELISA kit, and its residual enzymatic activity (amount of adenine released from a 2,551-bp DNA substrate) was determined with a biological activity assay (BAA). Regression analysis indicated that the inactivation of Stx1 as a function of time followed first-order kinetics. The half-lives determined at 60, 65, 70, 75, 80, and 85°C were 9.96, 3.19, 2.67, 0.72, 0.47, and 0.29 min, respectively, using the BAA. The half-lives determined by the ELISA with thermal treatments at 70, 75, 80, and 85°C were 40.47, 11.03, 3.64, and 1.40 min, respectively. The Z, Q(10), and Arrhenius activation energy values derived by both assays were dissimilar, indicating that the rate of inactivation of the active site of Stx1 was less sensitive to temperature change than was denaturation of the epitope(s) used in the ELISA. These values were 10.28°C and 9.40 and 54.70 kcal/mol, respectively, with the ELISA and 16°C and 4.11 and 34 kcal/mol, respectively, with the BAA. Orange juice enhanced Stx1 inactivation as a function of increasing temperature, whereas inactivation in 2% milk was not very much different from that in phosphate-buffered saline. Our investigation indicates that the ELISA would be a reliable method for detecting the residual toxicity of heat-treated Stx1 because the half-lives determined with the ELISA were greater than those determined with the BAA (faster degradation) at all temperatures and were highly correlated (R(2) = 0.994) with those determined with the BAA.
Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K
2017-10-01
A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection < 1 ppm full fat almond, limit of quantification < 5 ppm full fat almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability < 15% CV). The target antigens were stable and detectable in whole almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.
Mårtensson, Johan; Xu, Shengyuan; Bell, Max; Martling, Claes-Roland; Venge, Per
2012-10-09
The distinction between monomeric human neutrophil lipocalin/neutrophil gelatinase-associated lipocalin (HNL/NGAL), secreted by injured kidney tubular cells, and dimeric HNL/NGAL, released by activated neutrophils, is important to accurately diagnose acute kidney injury (AKI). 132 urine samples from 44 intensive care unit (ICU) patients and five urine samples from non-ICU patients with urinary tract infections (UTIs) were analyzed by two monoclonal enzyme-linked immunosorbent assays (ELISA-1 and ELISA-2). The presence of monomeric and/or dimeric HNL/NGAL in each sample was visualized by Western blotting. The ELISA-1 detected both monomeric and dimeric HNL/NGAL whereas the ELISA-2 almost exclusively detected dimeric HNL/NGAL with an area under the receiver-operating characteristics curve (AuROC) of 0.90. The ELISA-1/ELISA-2 ratio detected the monomeric form with an AuROC of 0.92. In 32 AKI patients, dimer-specific ELISA-2 levels decreased pre-AKI whereas the monomer-specific ELISA-1/ELISA-2 ratio gradually increased beyond AKI diagnosis. High ELISA-2 levels and/or low ELISA-1/ELISA-2 ratios detected a predominance of dimeric HNL/NGAL in urine from the patients with UTIs. In combination, our two ELISAs distinguish monomeric HNL/NGAL, produced by the kidney epithelium, from dimeric HNL/NGAL, released by neutrophils during AKI development, as well as reduce the confounding effect of neutrophil involvement when bacteriuria is present. Copyright © 2012 Elsevier B.V. All rights reserved.
Anti-signal recognition particle autoantibody ELISA validation and clinical associations.
Aggarwal, Rohit; Oddis, Chester V; Goudeau, Danielle; Fertig, Noreen; Metes, Ilinca; Stephens, Chad; Qi, Zengbiao; Koontz, Diane; Levesque, Marc C
2015-07-01
The aim of this study was to develop and validate a quantitative anti-signal recognition particle (SRP) autoantibody serum ELISA in patients with myositis and longitudinal association with myositis disease activity. We developed a serum ELISA using recombinant purified full-length human SRP coated on ELISA plates and a secondary antibody that bound human IgG to detect anti-SRP binding. Protein immunoprecipitation was used as the gold standard for the presence of anti-SRP. Serum samples from three groups were analysed: SRP(+) myositis subjects by immunoprecipitation, SRP(-) myositis subjects by immunoprecipitation and non-myositis controls. The ELISA's sensitivity, specificity, positive predictive value and negative predictive value were evaluated. Percentage agreement and test-retest reliability were assessed. Serial samples from seven SRP immunoprecipitation-positive subjects were also tested, along with serum muscle enzymes and manual muscle testing. Using immunoprecipitation, we identified 26 SRP(+) myositis patients and 77 SRP(-) controls (including 38 patients with necrotizing myopathy). Non-myositis control patients included SLE (n = 4) and SSc (n = 7) patients. Anti-SRP positivity by ELISA showed strong agreement (97.1%) with immunoprecipitation (κ = 0.94). The sensitivity, specificity, positive predictive value, and negative predictive value of the anti-SRP ELISA were 88, 100, 100 and 96, respectively. The area under the curve was 0.94, and test-retest reliability was strong (r = 0.91, P < 0.001). Serial samples showed that anti-SRP levels paralleled changes in muscle enzymes and manual muscle testing. We developed a quantitative ELISA for detecting serum anti-SRP autoantibodies and validated the assay in myositis. Longitudinal assessment of SRP levels by ELISA may be a useful biomarker for disease activity. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Diagnosis of murine mycoplasmal infections by enzyme-linked immunosorbent assay (ELISA).
Davis, J; Cassell, G H; Gambill, G; Cox, N; Watson, H; Davidson, M
1987-06-01
ELISA is the currently accepted method for screening rodent colonies for Mycoplasma pulmonis infection. While this assay has greatly improved mycoplasmal detection, it suffers from major defects. Cross-reactions with M. arthritidis are the major technical problem, and prevent definitive diagnosis. Current methods for obtaining a definitive diagnosis are accurate in about 80% of cases, and include ELISA testing for both organisms, immunoblot analysis, and blocking of the murine reaction with heterologous serum. Another technical difficulty is the inherent variability in the assay, which can be overcome by rigid quality control measures and careful attention to detail. The difficulties that arise from the natural history of mycoplasmal infection in barrier-maintained colonies, i.e., low incidence of infected animals and delayed antibody response in animals infected with low numbers of organisms, seriously limit the usefulness of the ELISA. While the assay can be extremely useful in screening breeding colonies and in eliminating mycoplasmas from such colonies, it cannot easily be used to screen potential sources of weanling animals for experimental use.
Parween, Shahila; Nahar, Pradip
2013-10-15
In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.
Kittelberger, R; O'Keefe, J S; Meynell, R; Sewell, M; Rosati, S; Lambert, M; Dufour, P; Pépin, M
2006-02-01
To determine the diagnostic capability of a newly developed Western blot (WB) assay for the detection of serum antibodies against Mycoplasma agalactiae compared with conventional serological tests, and to identify the best test for routine diagnostic use. The serological test methods used were: two commercial indirect enzyme-linked immunosorbent assays (ELISA), viz ELISA-1, using a bacterial antigen preparation, and ELISA-2, using a recombinant protein (lipoprotein p48) antigen; the complement fixation test (CFT); and a newly developed WB assay, the latter both using a bacterial antigen preparation. Thirty sera from goats infected with M. agalactiae and 97 sera from non-infected sheep were tested using all four methods. Staining patterns in the WB were quite variable. An immuno-dominant band of 41 kDa was detected in 63% of sera from infected animals. The same band also appeared, although mostly very weakly, in 10% of sera from non-infected animals. When suspicious or very weak reactors were omitted, the diagnostic sensitivity (DSE) and diagnostic specificity (DSP), respectively, for the four assays were: WB=56.7%, 97.9%; ELISA-1=76.7%, 99.0%; ELISA-2=56.7%, 100%; and CFT=40.0%, 94.8%. ELISA-1 performed best in this comparison. While the WB can be used, it did not have a technical advantage over the ELISA. The CFT should be discouraged as the primary screening method for contagious agalactia and should be replaced by ELISA-1. Results from this study confirm that serological test methods for contagious agalactia are useful for the detection of infected flocks but will not detect every individual infected animal.
Zhao, Hongwei; Nan, Tiegui; Tan, Guiyu; Gao, Wei; Cao, Zhen; Sun, Shuo; Li, Zhaohu; Li, Qing X; Wang, Baomin
2011-09-19
Availability of highly sensitive assays for metal ions can help monitor and manage the environmental and food contamination. In the present study, a monoclonal antibody against Copper(II)-ethylenediaminetetraacetic acid was used to develop two sensitive ELISAs for Cu(II) analysis. Cobalt(II)-EDTA-BSA was the coating antigen in a heterologous indirect competitive ELISA (hicELISA), whereas Co(II)-EDTA-BSA-horseradish peroxidase (HRP) was the enzyme tracer in a heterologous direct competitive ELISA (hdcELISA). Both ELISAs were validated for detecting the content of Cu(II) in environmental waters. The ELISA data agreed well with those from graphite furnace atomic absorption spectroscopy. The methods of developing the Cu(II) hicELISA and hdcELISA are potentially applicable for developing ELISAs for other metals. The chelator-protein complexes such as EDTA-BSA and EDTA-BSA-HRP can form a suite of metal complexes having the consistent hapten density, location and orientation on the conjugates except the difference of the metal core, which can be used as ideal reagents to investigate the relationship between assay sensitivity and antibody affinities for the haptens and the analytes. The strategy of conjugating a haptenated protein directly with HRP can reduce the loss of HRP activity during the conjugation reaction and thus can be applicable for the development of ELISAs for small molecules. Copyright © 2011. Published by Elsevier B.V.
Friedrich, Adrián; Ledesma, Martín; Landone, Ignacio; Ferrari, Alejandro; Leoni, Juliana
2014-09-01
A monoclonal antibody (mAb) was produced against immunoglobulin M (IgM) of South American camelids. A single radial immunodiffusion (SRID) assay and a competitive enzyme-linked immunosorbent assay (ELISA) were developed to measure IgM in serum samples. Isotype and specificity of the mAb were assessed. The performance of the SRID assay was preliminarily evaluated in terms of working range, plate stability over a 4-week period, and initial intra- and interassay variation. The concentration of IgM was determined in 55 samples by SRID assay and ELISA, and results were not significantly different by t-test (0.64 ± 0.19 mg/ml for the SRID assay, and 0.58 ± 0.24 mg/ml for ELISA; P = 0.1489). The mAb was shown to be stable over the 4-week evaluation period, and the SRID assay was reproducible when tested in triplicate for intra-assay variability and in quadruplicate for interassay variability, with a percentage coefficient of variation of less than or equal to 5%. Also, the SRID assay proved to be sensitive enough to measure IgM levels in undiluted serum samples, and had a good correlation with ELISA. The current study is intended to submit a preliminary report of a mAb against IgM of South American camelids, and suggest the future potential of the mAb developed for diagnostic application, including use in the SRID assay. © 2014 The Author(s).
Salm, P; Taylor, P J; Clark, A; Balderson, G A; Grygotis, A; Norris, R L; Lynch, S V; Shaw, L M; Pond, S M
1997-12-01
The accuracy and imprecision of three assays used for therapeutic monitoring of tacrolimus were tested using blood-containing weighed-in amounts of the drug, an enzyme-linked immunosorbent assay (ELISA), a microparticle enzyme immunoassay (MEIA I), and a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS2) assay. Accuracy was acceptable for the HPLC-MS2 assay at all concentrations tested (< 10% deviation) and for the ELISA at 1.0 and 4.0 microg/l. Accuracy was not acceptable for the ELISA at 15.0 and 50.0 microg/l or for the MEIA I at all concentrations tested. Imprecision was acceptable for the HPLC-MS2 assay at all concentrations tested (coefficient of variation < 10%), for the ELISA at 15.0 and 50.0 microg/l, and for the MEIA I at 15.0 and 50.0 microg/l. Imprecision was not acceptable for the ELISA at 1.0 and 4.0 microg/l or for the MEIA I at 1.0 and 4.0 microg/l. This assessment with weighed-in amounts of tacrolimus verified the HPLC-MS2 assay as a reference method. The performance of the two immunoassays with HPLC-MS2 was then compared in the clinical setting using blood from patients with liver (n = 30) and renal (n = 37) transplants. In the liver transplant group (127 samples), the range of tacrolimus concentrations measured by HPLC-MS2, ELISA, and MEIA I was 1.9 to 31.8, 2.1 to 35.0, and less than 0.1 to 36.5 mg/l, respectively. In the renal transplant group (129 samples), the ranges were 1.7 to 26.1, 1.9 to 24.4, and 0.9 to 28.5 microg/l, respectively. Compared with the HPLC-MS2, the ELISA had minimal bias (0.1 to 0.2 microg/l) but unacceptable variability in values (SD > 13%). The MEIA I had unacceptable bias (1.7-1.8 microg/l) and variability (SD > 23%). These data indicated that neither the ELISA nor MEIA I is interchangeable with HPLC-MS2. Moreover, in view of the current trend to reduce the therapeutic dose of tacrolimus, quantitative results using the MEIA I would not be obtainable during therapeutic drug monitoring in some patients in whom effective therapeutic concentrations can be less than 5.0 microg/l.
Zhang, Na; Man, Lai; Sun, Jian-ping; Meng, Jia-zi; He, Yu-xian
2013-09-01
To identify human monoclonal HIV-l-neutralizing antibodies from an HIV-1 CRF07BC specific phage display antibody library by cell-based screening. 293T cells were transfected by pCH064. 2-Env plas mid and then used to biopan the phage antibody library. The positive phage clones were screened by cell based ELISA and sequenced for the variable region of heavy (VH) and light (VL) chains. The expressed Fabs were purified by Ni(+2) -NTA column and analyzed by SDS-PAGE. The cell- and gp120 protein-based ELISA as well as flow cytometry were used to measure Fab's binding activity. The neutralizing activity of Fabs was assessed by HIV-1 pseudoviruses. After 4-round biopanning, the binding phages to transfected cells were enriched about 650-folds. A total of 28 positive clones were screened out by cell ELISA and sequence analysis identified 5 different Fabs possessing unique VH and VL (2801, 2837, 2863, 2870 and 2920). Interestingly, these Fabs reacted with the Env-transfected 293T cells but not soluble gp120 proteins, suggesting that they might target conformation-dependent epitopes presenting on viral Env complex. We found that three Fabs (2801, 2863, 2870) exhibited potent neutralizing activity against CRF07_BC isolate CH120. 6 with IC50 of 2.24, 0.89 and 3.09 microg/mL respectively, and that 2801 and 2863 cross-neutral ized the subtype B isolate SF162 at IC50 of 0.69 and 3.52 microg/mL respectively. In conclusion, the HIV-1 Env-transfected 293T cells can be used to efficiently enrich and screen the phage antibody library and isolate human monoclonal HIV-1-neutralizing Fabs that target the Env complex-dependent conformational epitopes. Therefore, our studies provide a powerful platform for exploring the mechanism of HIV-1 neu tralizing response and for designing AIDS vaccines.
Casais, R; Goyena, E; Martínez-Carrasco, C; Ruiz de Ybáñez, R; Alonso de Vega, F; Ramis, G; Prieto, J M; Berriatua, E
2013-10-18
The performance of an indirect ELISA test based on Sarcoptes scabiei var hominis recombinant antigen Ssλ20ΔB3 (rec-ELISA), to diagnose pig mange was investigated in 15 experimentally infected and non-infected pigs and 692 commercial pigs from 16 herds in southeast Spain. These latter animals included 6-7 month old fatteners (13 herds), 11-12 month old replacement sows (1 herd) and ≥24 month old breeding sows (7 herds). All pigs were examined for mites in ear skin scrapings and the presence of S. scabiei-associated macroscopic dermatitis; moreover, fatteners were also tested for antibodies against porcine viruses including: Aujeszky disease virus (ADV), swine influenza virus (SIV), type 2 porcine circovirus (PCV2) and porcine respiratory and reproductive syndrome virus (PRRSV). S. scabiei and chronic hyperkeratotic dermatitis were detected in breeding sows from 6 herds. Mite prevalence in other pigs was 83% in replacement sows, 0% in 7 fattener's herds and 3-82% in other fattener's herds. All fattener herds had pigs with acute hypersensitivity dermatitis and the percentage of affected pigs and lesion area was significantly greater in S. scabiei infected ones. Rec-ELISA relative optical densities (RODs) were greater in older than in young pigs, as well as in infected compared to non-infected pigs. However, RODs differed significantly between infected individuals, regardless of age and origin (commercial or experimental) and the herd prevalence of S. scabiei. Low repeatability between ELISA microtiter plates, suggesting variable specific antibody binding to antigen, are likely partly responsible for ROD variation. Other potential causes of variation were examined in fatteners using random effects logistic regression analysis, after defining a seropositivity threshold value with receiver-operating characteristics (ROC) analysis. The logistic model indicated that seropositivity was associated with large dermatitis areas and with the only herd with low PCV2 seroprevalence. Pigs with more extensive dermatitis may have older infections and more rec-ELISA detectable antibodies. The possibility that PCV2, a recognized immunosupressor, depresses antibody production against S. scabiei infection merits further attention. In summary, results indicate some potential of the studied rec-ELISA as a complementary tool for herd-level swine mange diagnosis, and that work to reduce internal and external sources of assay variation is essential. Copyright © 2013 Elsevier B.V. All rights reserved.
ELISA microarray technology as a high-throughput system for cancer biomarker validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zangar, Richard C.; Daly, Don S.; White, Amanda M.
A large gap currently exists between the ability to discover potential biomarkers and the ability to assess the real value of these proteins for cancer screening. One major challenge in biomarker validation is the inherent variability in biomarker levels. This variability stems from the diversity across the human population and the considerable molecular heterogeneity between individual tumors, even those that originate from a single tissue. Another major challenge with cancer screening is that most cancers are rare in the general population, meaning that the specificity of an assay must be very high if the number of false positive is notmore » going to be much greater than the number of true positives. Because of these challenges with biomarker validation, it is necessary to analysis of thousands of samples before a clear idea of the utility of a screening assay can be determined. Enzyme-linked immunosorbent assay (ELISA) microarray technology can simultaneously quantify levels of multiple proteins and has the potential to accelerate biomarker validation. In this review, we discuss current ELISA microarray technology and the enabling advances needed to achieve the reproducibility and throughput that are required to evaluate cancer biomarkers.« less
Inui, Hideyuki; Takeuchi, Tetsuya; Uesugi, Akari; Doi, Fumito; Takai, Mikio; Nishi, Kosuke; Miyake, Shiro; Ohkawa, Hideo
2012-02-22
Coplanar polychlorinated biphenyls (Co-PCBs) consisting of non-ortho and mono-ortho-chlorinated PCBs are dioxin-like compounds and cause wide contamination in the environment. To monitor Co-PCB residues, it was attempted to establish an enzyme-linked immunosorbent assay (ELISA) with monoclonal and recombinant antibodies selective to Co-PCBs. When 3,3',5,5'-tetrachlorobiphenoxybutyric acid (PCBH)-keyhole limpet hemocyanin conjugate was immunized into mice, two monoclonal antibodies, Mab-0217 and Mab-4444, were obtained. 3,3',5,5'-Tetrachlorobiphenyl (PCB80) was determined with an IC(50) value of 2.6 and 0.46 ng mL(-1) in ELISA based on Mab-0217 and Mab-4444, respectively. Mab-4444 cross-reacted with Co-PCB congeners, except for PCB77 and PCB81. Mab-0217 reacted with PCB80 and cross-reacted with PCB111. A single-chain variable fragment (scFv) antibody derived from Mab-4444 was produced in recombinant Escherichia coli cells. The scFv antibody showed nearly the same sensitivity toward PCBH as the parent monoclonal antibody in ELISA. These results clearly suggested that Mab-4444 and its scFv antibodies were suitable for monitoring the representative congeners of Co-PCBs.
Chung, Chungwon J; Suarez, Carlos E; Bandaranayaka-Mudiyanselage, Carey L; Bandaranayaka-Mudiyanselage, Chandima-Bandara; Rzepka, Joanna; Heiniger, T J; Chung, Grace; Lee, Stephen S; Adams, Ethan; Yun, Grace; Waldron, Susan J
2017-02-13
Cattle persistently infected with Babesia bovis are reservoirs for intra- and inter-herd transmission. Since B. bovis is considered a persistent infection, developing a reliable, high-throughput assay that detects antibody during all stages of the infection could be pivotal for establishing better control protocols. A modified indirect enzyme-linked immunosorbent assay (MI-ELISA) was developed using the spherical body protein-4 (SBP4) of B. bovis to detect antibody against diverse strains through all infection stages in cattle. This SBP4 MI-ELISA was evaluated for sensitivity and specificity against field sera from regions with endemic and non-endemic B. bovis. Sera were also evaluated from cattle infected experimentally with various doses and strains during acute and persistent infection with parasitemia defined by nested PCR. The format variables for SBP4 MI-ELISA were optimized and the cutoff for positive and negative interpretation was determined based on receiver operating characteristic curve analysis using B. bovis positive and negative sera tested in the reference immunofluorescence assay (IFA). The diagnostic specificity of the SBP4 MI-ELISA using IFA-negative sera collected from Texas was 100%, significantly higher than the cELISA (90.4%) based on an epitope in the rhoptry-associated protein-1 (RAP-1 cELISA). The diagnostic sensitivity of the SBP4 MI-ELISA was 98.7% using the IFA-positive sera collected from several areas of Mexico, in contrast to that of the RAP-1 cELISA at 60% using these same sera. In cattle infected with low and high doses of three B. bovis strains, the SBP4 MI-ELISA remained antibody positive for 11 months or more after initial detection at 10 to 13 days post-inoculation. However, the RAP-1 cELISA did not reliably detect antibody after eight months post-inoculation despite the fact that parasitemia was occasionally detectable by PCR. Furthermore, initial antibody detection by RAP-1 cELISA in low-dose infected animals was delayed approximately nine and a half days compared to the SBP4 MI-ELISA. These results demonstrate excellent diagnostic sensitivity and specificity of the novel SBP4 MI-ELISA for cattle with acute and long-term carrier infections. It is posited that use of this assay in countries that have B. bovis-endemic herds may be pivotal in preventing the spread of this disease to non-endemic herds.
Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.
1994-01-01
A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645
Jiang, Wenzhi; Cossey, Sarah; Rosenberg, Julian N; Oyler, George A; Olson, Bradley J S C; Weeks, Donald P
2014-09-25
Cell walls are essential for most bacteria, archaea, fungi, algae and land plants to provide shape, structural integrity and protection from numerous biotic and abiotic environmental factors. In the case of eukaryotic algae, relatively little is known of the composition, structure or mechanisms of assembly of cell walls in individual species or between species and how these differences enable algae to inhabit a great diversity of environments. In this paper we describe the use of camelid antibody fragments (VHHs) and a streamlined ELISA assay as powerful new tools for obtaining mono-specific reagents for detecting individual algal cell wall components and for isolating algae that share a particular cell surface component. To develop new microalgal bioprospecting tools to aid in the search of environmental samples for algae that share similar cell wall and cell surface components, we have produced single-chain camelid antibodies raised against cell surface components of the single-cell alga, Chlamydomonas reinhardtii. We have cloned the variable-region domains (VHHs) from the camelid heavy-chain-only antibodies and overproduced tagged versions of these monoclonal-like antibodies in E. coli. Using these VHHs, we have developed an accurate, facile, low cost ELISA that uses live cells as a source of antigens in their native conformation and that requires less than 90 minutes to perform. This ELISA technique was demonstrated to be as accurate as standard ELISAs that employ proteins from cell lysates and that generally require >24 hours to complete. Among the cloned VHHs, VHH B11, exhibited the highest affinity (EC50 < 1 nM) for the C. reinhardtii cell surface. The live-cell ELISA procedure was employed to detect algae sharing cell surface components with C. reinhardtii in water samples from natural environments. In addition, mCherry-tagged VHH B11 was used along with fluorescence activated cell sorting (FACS) to select individual axenic isolates of presumed wild relatives of C. reinhardtii and other Chlorphyceae from the same environmental samples. Camelid antibody VHH domains provide a highly specific tool for detection of individual cell wall components of algae and for allowing the selection of algae that share a particular cell surface molecule from diverse ecosystems.
C2K77 ELISA detects cleavage of type II collagen by cathepsin K in equine articular cartilage.
Noé, B; Poole, A R; Mort, J S; Richard, H; Beauchamp, G; Laverty, S
2017-12-01
Develop a species-specific ELISA for a neo-epitope generated by cathepsin K cleavage of equine type II collagen to: (1) measure cartilage type II collagen degradation by cathepsin K in vitro, (2) identify cytokines that upregulate cathepsin K expression and (3) compare cathepsin K with matrix metalloproteinase (MMP) collagenase activity in stimulated cartilage explants and freshly isolated normal and osteoarthritic (OA) articular cartilages. A new ELISA (C2K77) was developed and tested by measuring the activity of exogenous cathepsin K on equine articular cartilage explants. The ELISA was then employed to measure endogenous cathepsin K activity in cultured cartilage explants with or without stimulation by interleukin-1 beta (IL-1β), tumour necrosis-alpha (TNF-α), oncostatin M (OSM) and lipopolysaccharide (LPS). Cathepsin K activity in cartilage explants (control and osteoarthritic-OA) and freshly harvested cartilage (control and OA) was compared to that of MMPs employing C2K77 and C1,2C immunoassays. The addition of Cathepsin K to normal cartilage caused a significant increase (P < 0.01) in the C2K77 epitope release. Whereas the content of C1,2C, that reflects MMP collagenase activity, was increased in media by the addition to cartilage explants of TNF-α and OSM (P < 0.0001) or IL-1β and OSM (P = 0.002), no change was observed in C2K77 which also unchanged in OA cartilages compared to normal. The ELISA C2K77 measured the activity of cathepsin K in equine cartilage which was unchanged in OA cartilage. Cytokines that upregulate MMP collagenase activity had no effect on endogenous cathepsin K activity, suggesting a different activation mechanism that requires further study. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Hu, Jianzhong; Nudelman, German; Shimoni, Yishai; Kumar, Madhu; Ding, Yaomei; López, Carolina; Hayot, Fernand; Wetmur, James G.; Sealfon, Stuart C.
2011-01-01
In the first few hours following Newcastle disease viral infection of human monocyte-derived dendritic cells, the induction of IFNB1 is extremely low and the secreted type I interferon response is below the limits of ELISA assay. However, many interferon-induced genes are activated at this time, for example DDX58 (RIGI), which in response to viral RNA induces IFNB1. We investigated whether the early induction of IFNBI in only a small percentage of infected cells leads to low level IFN secretion that then induces IFN-responsive genes in all cells. We developed an agent-based mathematical model to explore the IFNBI and DDX58 temporal dynamics. Simulations showed that a small number of early responder cells provide a mechanism for efficient and controlled activation of the DDX58-IFNBI positive feedback loop. The model predicted distributions of single cell responses that were confirmed by single cell mRNA measurements. The results suggest that large cell-to-cell variation plays an important role in the early innate immune response, and that the variability is essential for the efficient activation of the IFNB1 based feedback loop. PMID:21347441
Desomorphine Screening Using Commercial Enzyme-Linked Immunosorbent Assays.
Winborn, Jessica; Kerrigan, Sarah
2017-06-01
Desomorphine ("Krokodil") is a semi-synthetic opioid that has drawn attention as a recreational drug, particularly in Russia, neighboring former Soviet Republics, Eastern and Central Europe. It has no accepted medicinal uses and is currently a schedule I drug in the United States. In clandestine environments, desomorphine is synthesized from codeine using red phosphorous, hydroiodic acid and gasoline. Residual starting materials in illicit preparations have been associated with severe dermatological effects and extensive tissue necrosis. Desomorphine is not well studied, and there are limited reports concerning its pharmacology or detection in biological matrices. Immunoassays are widely relied upon for both antemortem and postmortem toxicology screening. Although desomorphine is an opioid of the phenanthrene-type, its ability to bind to conventional opioid antibodies has not been described. In this report we describe the cross-reactivity of desomorphine using six commercially available enzyme-linked immunosorbent assays (Immunalysis Opiates Direct ELISA, Immunalysis Oxycodone/Oxymorphone Direct ELISA, Randox Opiate ELISA, OraSure Technologies OTI Opiate Micro-plate EIA, Neogen Opiate Group ELISA and Neogen Oxycodone/Oxymorphone ELISA). Cross-reactivites were highly variable between assays, ranging from 77 to <2.5%. In general, assays directed towards morphine produced greater cross-reactivity with desomorphine than those directed towards oxycodone. The Immunalysis Opiates Direct ELISA produced the greatest cross-reactivity, although several of the assays evaluated produced cross-reactivity of a sufficient magnitude to be effective for desomorphine screening. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lexhaller, Barbara; Tompos, Christine; Scherf, Katharina Anne
2017-12-15
Monitoring the compliance of gluten-free foods to the regulatory threshold of 20mg/kg of gluten is essential for celiac disease patients. The different enzyme-linked immunosorbent assays (ELISAs) for gluten detection each have specific characteristics, but there are only a few systematic comparisons. This fundamental study compared the specificities and sensitivities of the R5, G12 and Skerritt monoclonal and two polyclonal antibodies to well-defined gluten protein types (GPT) isolated from wheat, rye and barley flours. Quantitation of protein concentrations by reversed-phase high-performance liquid chromatography provided independent reference values. The ELISA responses showed high variability depending on the type of cereal, the GPT and the antibody used. Overall, ω1,2-gliadins and γ-75k-secalins were most reactive, whereas ω5-gliadins and γ-, B- and D-hordeins were detected with the lowest sensitivities. These results revealed which GPT each antibody is most sensitive to and provided novel insights that will be helpful for appropriate calibration of ELISAs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Grandval, Philippe; De Caro, Alain; De Caro, Josiane; Sias, Barbara; Carrière, Frédéric; Verger, Robert; Laugier, René
2004-01-01
Human pancreatic lipases (HPL) include the classical HPL, and two related proteins known as pancreatic lipase-related proteins 1 and 2 (HPLRP1 and 2). The aim of this study was to develop an ELISA for specifically quantifying the classical-HPL level in sera of patients with and without pancreatic disorders. The specific activity of various human (including classical-HPL) and microbial lipases was measured using Lipa Vitros and potentiometric (pH-stat) assays. A double sandwich ELISA was also set up, using an anti-classical-HPL polyclonal antibody and a biotinylated monoclonal antibody (mAb 146-40) specific to the classical-HPL. Sera (n = 53) were collected from patients with and without pancreatic disorders. The lipase concentration was deduced from the measured lipolytic activity and compared with the corresponding classical-HPL concentration, measured with the ELISA. Both the purified HPLRP2 and 3 lipases of microbial origin were found to have a significant and unexpected lipolytic activity under the standard Lipa Vitros assay, whereas the ELISA test developed in the present study was found to be specific for the classical-HPL, due to the absence of cross-reactivity between mAb 146-40, HPLRP1 and HPLRP2. The efficiency of the ELISA was assessed in terms of its reproducibility and accuracy. The lower detection limit of classical-HPL was found to be 0.03 microg/l. A good correlation was found to exist between the lipase concentrations obtained in the ELISA, pH-stat and Lipa Vitros tests, in both the control and pathological groups. This is the first time a specific method of measuring classical-HPL in human serum has been proposed. Using this ELISA, we established with the 53 sera selected in the present study, that the Lipa Vitros assay as well as the pH-stat assay were mostly detecting classical pancreatic lipase. However, it is possible that other lipases such as HPLRP2 or lipases of microbial origin, present in some pathological sera, may well interfere with the Lipa Vitros assay. Copyright 2004 S. Karger AG, Basel and IAP.
Adult Stem Cell-Based Enhancement of Nerve Conduit for Peripheral Nerve Repair
2017-10-01
neurotrophically activated cell types and conditioned media (via RT-PCR and ELISA of neurotrophic factors), followed by cell storage Specific objective 9...Mesenchymal Progenitor Cells (NI-MiMPCs) and Mesenchymal Stem Cells (MSCs), quantified via ELISA . MiMPCs and MSCs were cultured in neurotrophic induction...LIF, (E) osteonectin, and (F) clusterin. All ELISA results are expressed in pg/ml or ng/ml produced per million cells. Medium taken from NI-MiMPC
The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment
2017-10-01
PI Mohler). Immunostaining of prostate cancer biopsy specimen of patients who qualified for active surveillance is complete (PI Goodrich). ELISA assay...specimens for use in constructing tissue microarrays, developing and optimizing ELISA assays to detect Thoc1 protein and anti-Thoc1 autoantibodies...set of TMAs made from 700 patients available at RPCI has been immunostained for PMP22 (figure 5). ELISA assays for measuring pThoc1 and pThoc1
2016-04-01
streptavidin-phycoerythrin (PE) similar to sandwich enzyme-linked immunosorbent assays ( ELISAs ). The 3 fluorescent markers (2 beads plus PE) allow for...within the kit, this worked out to a set of expensive, problematic, and subjective ELISA . The space on the black-96 well plate was split between cell...ARL US Army Research Laboratory BBB blood–brain barrier CSF cerebral spinal fluid DOD US Department of Defense ELISA enzyme-linked immunosorbent
The Thoc1 Ribonucleoprotein as a Novel Biomarker for Prostate Cancer Treatment Assignment
2016-10-01
patients on active surveillance is ongoing (PI Mohler). Developing ELISA assays for measuring pThoc1 and pThoc1 autoantibodies is complete (PI...assessment of 1146 patient specimens for use in constructing tissue microarrays, developing and optimizing ELISA assays to detect anti-Thoc1 autoantibodies...700 patients available at RPCI has been immunostained for PMP22 (figure 3). ELISA assays for measuring pThoc1 and pThoc1 autoantibodies have been
Reiter-Owona, Ingrid; Grüner, Beate; Frosch, Matthias; Hoerauf, Achim; Kern, Peter; Tappe, Dennis
2009-01-01
Sera of 50 patients with either cystic (CE) or alveolar echinococcosis (AE) in different clinical stages were examined for the presence of anti-Echinococcus-antibodies. Antibody-screening was performed with ELISA, IHA and IFAT, and confirmatory testing was done by the commercialized E. multilocularis-specific Em2plus-ELISA versus an in-house E. multilocularis-specific Em10-ELISA. Sera with discrepant confirmatory results were subjected to a commercial Echinococcus IgG Western blot (WB). In sera from patients with CE, the Em2plus-ELISA showed cross-reactions in 23.5%, whereas the Em10-ELISA did not exhibit any cross-reactivity. Cross-reactivity paralleled active infection with high antibody titers in the screening assays. In sera from patients with AE, confirmation by both ELISAs was achieved in 57.6%, mostly in patients with an advanced stage of the disease and high antibody titers in the screening assays. False-negative reactions of both ELISAs occurred in 30.3%, mostly in patients who had low antibody levels in the screening tests. The Em2plus-ELISA exhibited fewer false-negative reactions than the Em10-ELISA. The WB confirmed the positive results of either assay and was the assay with the highest reliability at different stages of CE and AE, followed by the Em2plus-ELISA for AE. High antibody titers in the screening assays will favour the detection of species-specific antibodies in either form.
COMPARISON OF ELISAS FOR DETECTING VITELLOGENIN IN THE FATHEAD MINNOW (PIMEPHALES PROMELAS)
Measurement of vitellogenin (VTG) concentrations in the fathead minnow is currently being evaluated and considered for screening of endocrine active substances. One of the proposed methods, an enzyme-linked immunosorbent assay (ELISA) based on VTG from carp, was recently evaluate...
The feasibility of harmonizing gluten ELISA measurements.
Rzychon, Malgorzata; Brohée, Marcel; Cordeiro, Fernando; Haraszi, Reka; Ulberth, Franz; O'Connor, Gavin
2017-11-01
Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Development of an indirect method for measuring porcine pancreatic lipase in human duodenal fluid.
Tuvignon, N; Abousalham, A; Tocques, F; De Caro, J; De Caro, A; Laugier, R; Carrière, F
2008-12-15
Patients with exocrine pancreatic insufficiency are usually treated with porcine pancreatic enzymes but the bioavailability of these enzymes in the gut remains a matter of discussion. In order to determine the duodenal availability of porcine pancreatic lipase (PPL) present in pancreatic extracts (PE) taken orally, we developed a method for quantifying PPL in samples containing both PPL and human pancreatic lipase (HPL). Total pancreatic lipase activity measurements using the pH-stat technique and tributyrin as substrate were combined with an HPL-specific ELISA. Based on the known specific activity of the purified HPL, its activity was deduced from the ELISA measurements, and the PPL activity was obtained by subtracting the HPL activity from the total pancreatic lipase activity. This assay was established and validated using various samples containing pure PPL and recombinant HPL or PE, mixed or not with human duodenal juice. Samples collected in vivo from patients treated with PE were also tested. It was found that PPL did not affect the HPL ELISA, and the indirect PPL assay gave a measurement accuracy of 6.6% with the samples containing pure PPL and 10% with those containing PE. This assay was also used successfully to discriminate between PPL and the endogenous HPL present in the duodenal contents of patients with severe pancreatic insufficiency treated with PE. This method might provide a useful means of assessing the availability of PEs at their site of action, in the absence of a PPL-specific ELISA.
Ishikawa, Fumihiro; Miyamoto, Kengo; Konno, Sho; Kasai, Shota; Kakeya, Hideaki
2015-12-18
A significant gap exists between protein engineering and enzymes used for the biosynthesis of natural products, largely because there is a paucity of strategies that rapidly detect active-site phenotypes of the enzymes with desired activities. Herein, we describe a proof-of-concept study of an enzyme-linked immunosorbent assay (ELISA) system for the adenylation (A) domains in nonribosomal peptide synthetases (NRPSs) using a combination of active site-directed probes coupled to a 5'-O-N-(aminoacyl)sulfamoyladenosine scaffold with a biotin functionality that immobilizes probe molecules onto a streptavidin-coated solid support. The recombinant NRPSs have a C-terminal His-tag motif that is targeted by an anti-6×His mouse antibody as the primary antibody and a horseradish peroxidase-linked goat antimouse antibody as the secondary antibody. These probes can selectively capture the cognate A domains by ligand-directed targeting. In addition, the ELISA technique detected A domains in the crude cell-free homogenates from the Escherichia coli expression systems. When coupled with a chromogenic substrate, the antibody-based ELISA technique can visualize probe-protein binding interactions, which provides accurate readouts of the A-domain functions in NRPS enzymes. To assess the ELISA-based engineering of the A domains of NRPSs, we reprogramed 2,3-dihydroxybenzoic acid (DHB)-activating enzyme EntE toward salicylic acid (Sal)-activating enzymes and investigated a correlation between binding properties for probe molecules and enzyme catalysts. We generated a mutant of EntE that displayed negligible loss in the kcat/Km value with the noncognate substrate Sal and a corresponding 48-fold decrease in the kcat/Km value with the cognate substrate DHB. The resulting 26-fold switch in substrate specificity was achieved by the replacement of a Ser residue in the active site of EntE with a Cys toward the nonribosomal codes of Sal-activating enzymes. Bringing a laboratory ELISA technique and adenylating enzymes together using a combination of active site-directed probes for the A domains in NRPSs should accelerate both the functional characterization and manipulation of the A domains in NRPSs.
Usefulness of ELISA Methods for Assessing LPS Interactions with Proteins and Peptides
Martínez-Sernández, Victoria; Orbegozo-Medina, Ricardo A.; Romarís, Fernanda; Paniagua, Esperanza; Ubeira, Florencio M.
2016-01-01
Lipopolysaccharide (LPS), the major constituent of the outer membrane of Gram-negative bacteria, can trigger severe inflammatory responses during bacterial infections, possibly leading to septic shock. One approach to combatting endotoxic shock is to neutralize the most conserved part and major mediator of LPS activity (lipid A) with LPS-binding proteins or peptides. Although several available assays evaluate the biological activity of these molecules on LPS (e.g. inhibition of LPS-induced TNF-α production in macrophages), the development of simple and cost-effective methods that would enable preliminary screening of large numbers of potential candidate molecules is of great interest. Moreover, it would be also desirable that such methods could provide information about the possible biological relevance of the interactions between proteins and LPS, which may enhance or neutralize LPS-induced inflammatory responses. In this study, we designed and evaluated different types of ELISA that could be used to study possible interactions between LPS and any protein or peptide. We also analysed the usefulness and limitations of the different ELISAs. Specifically, we tested the capacity of several proteins and peptides to bind FITC-labeled LPSs from Escherichia coli serotypes O111:B4 and O55:B5 in an indirect ELISA and in two competitive ELISAs including casein hydrolysate (hCAS) and biotinylated polymyxin B (captured by deglycosylated avidin; PMX) as LPS-binding agents in the solid phase. We also examined the influence of pH, detergents and different blocking agents on LPS binding. Our results showed that the competitive hCAS-ELISA performed under mildly acidic conditions can be used as a general method for studying LPS interactions, while the more restrictive PMX-ELISA may help to identify proteins/peptides that are likely to have neutralizing properties in vitro or in vivo. PMID:27249227
Chaya, Dr; Parija, Subhash Chandra
2013-07-01
Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.
López, Lissett; Venteo, Angel; García, Marga; Camuñas, Ana; Ranz, Ana; García, Julia; Sarraseca, Javier; Anaya, Carmen; Rueda, Paloma
2009-09-01
A new commercially available antigen-capture, blocking enzyme-linked immunosorbent assay (antigen-capture b-ELISA), based on baculovirus truncated-S recombinant protein of Transmissible gastroenteritis virus (TGEV) and 3 specific monoclonal antibodies, was developed and evaluated by examining a panel of 453 positive Porcine respiratory coronavirus (PRCoV), 31 positive TGEV, and 126 negative field sera by using another commercially available differential coronavirus b-ELISA as the reference technique to differentiate TGEV- from PRCoV-induced antibodies. The recombinant S protein-based ELISA appeared to be 100% sensitive for TGEV and PRCoV detection and highly specific for TGEV and PRCoV detection (100% and 92.06%, respectively), when qualitative results (positive or negative) were compared with those of the reference technique. In variability experiments, the ELISA gave consistent results when the same serum was evaluated on different wells and different plates. These results indicated that truncated recombinant S protein is a suitable alternative to the complete virus as antigen in ELISA assays. The use of recombinant S protein as antigen offers great advantages because it is an easy-to-produce, easy-to-standardize, noninfectious antigen that does not require further purification or concentration. Those advantages represent an important improvement for antigen preparation, in comparison with other assays in which an inactivated virus from mammalian cell cultures is used.
Kumar, Pradeep; Saini, Monika; Kumar, Dharmendra; Jan, M H; Swami, Dheer Singh; Sharma, R K
2016-03-01
The present study is the first to quantify leptin in seminal plasma of buffalo and investigate its relationship with seminal attributes. Ten ejaculates each from 10 Murrah buffalo bulls were collected. Semen quality variables such as semen volume, sperm concentration, sperm abnormalities, membrane integrity, antioxidant enzyme activities (superoxide dismutase, catalase and total antioxidant capacity), malondialdehyde (MDA) concentration, as well as sperm kinetics and motility variables were evaluated. The leptin concentration in serum and seminal plasma were estimated by the ELISA method. Bulls were classified in two groups on the basis of sperm concentration with Group I having >800 million sperm/mL and Group II <500 million sperm/mL. Greater (P<0.05) mean sperm abnormalities, seminal leptin concentrations and MDA concentrations were recorded in Group II than Group I. The seminal leptin was positively correlated with sperm abnormalities and MDA concentration while being negatively correlated with sperm concentration, but there was no correlation with sperm kinetic and motility variables, sperm membrane integrity and seminal plasma antioxidant enzyme activity. Thus, the data suggest that seminal leptin has a role in spermatogenesis and can be used as a marker for spermatogenesis to predict the capacity of buffalo bulls for semen production. Copyright © 2016 Elsevier B.V. All rights reserved.
Krieger, Christine C.
2014-01-01
Excess production of hyaluronan (hyaluronic acid [HA]) in the retro-orbital space is a major component of Graves' ophthalmopathy, and regulation of HA production by orbital cells is a major research area. In most previous studies, HA was measured by ELISAs that used HA-binding proteins for detection and rooster comb HA as standards. We show that the binding efficiency of HA-binding protein in the ELISA is a function of HA polymer size. Using gel electrophoresis, we show that HA secreted from orbital cells is primarily comprised of polymers more than 500 000. We modified a commercially available ELISA by using 1 million molecular weight HA as standard to accurately measure HA of this size. We demonstrated that IL-1β-stimulated HA secretion is at least 2-fold greater than previously reported, and activation of the TSH receptor by an activating antibody M22 from a patient with Graves' disease led to more than 3-fold increase in HA production in both fibroblasts/preadipocytes and adipocytes. These effects were not consistently detected with the commercial ELISA using rooster comb HA as standard and suggest that fibroblasts/preadipocytes may play a more prominent role in HA remodeling in Graves' ophthalmopathy than previously appreciated. PMID:24302624
An ELISA method detecting the active form of suPAR.
Zhou, Xiaolei; Xu, Mingming; Huang, Hailong; Mazar, Andrew; Iqbal, Zafar; Yuan, Cai; Huang, Mingdong
2016-11-01
Urokinase plasminogen activator receptor (uPAR) exists in a number of formats in human plasma, including soluble uPAR (suPAR) and uPAR fragments. We developed an ELISA method to detect specifically the active form suPAR, which binds to its natural ligand uPA. The intra CV and inter CV of this ELISA assay is 8.5% and 9.6% respectively, and the assay can recover 99.74% of added recombinant suPAR from 10% plasma. This assay is quite sensitive, capable of detecting down to 15pg/ml of suPAR, and can measure suPAR concentrations in the range of 0.031-8ng/ml with high linear relationship. Plasma samples from pregnant women were also measured for the active form of suPAR with this assay, giving an averaged level of 1.39ng/ml, slightly higher than the level of pooled plasma from healthy donors (0.96ng/ml). This study demonstrates the feasibility to measure the active form of suPAR, which will likely have value in clinical applications. Copyright © 2016. Published by Elsevier B.V.
Clinical expression of lolitrem B (perennial ryegrass) intoxication in horses.
Johnstone, L K; Mayhew, I G; Fletcher, L R
2012-05-01
Perennial ryegrass staggers is purported to be a common neurological mycotoxicosis of horses but the case description lacks detail and evidence. To describe the clinical syndrome of lolitrem B intoxication in horses, limiting tests to those that are applicable to clinical practice, and to assess the potential value of enzyme-linked immunosorbent assay (ELISA) tests for lolitrem B in horse body fluids. Seven horses in 2 separate groups were fed perennial ryegrass seed and hay containing 2 ppm lolitrem B. Paired data were collected prior to and after 2 weeks exposure to lolitrem B, including video-documented neurological examination and clinical examination. All horses developed a variable degree of tremor and ataxia when exposed to lolitrem B. Tremor depended on the level of activity and included a subtle, rapid tremor of the eyeball. Ataxia was exaggerated by blindfolding and primarily involved a truncal sway and irregular, but predictable, limb placements. No change was detected in urine lolitrem B levels and, although plasma lolitrem B increased during the treatment period, levels did not correlate with the severity of clinical signs displayed. Limb swelling, heel lesions and serous nasal discharge were also observed in horses most severely intoxicated. The clinical effects of lolitrem B intoxication in horses primarily involve action-related tremors and symmetrical vestibular ataxia. Ergovaline may have caused the limb swelling, heel lesions and serous nasal discharge. Plasma ELISA for lolitrem B may be of diagnostic use in the future. This study provides a clearer appreciation of the clinical signs and variability of perennial ryegrass intoxication in horses. © 2011 EVJ Ltd.
Fournet, Florence; Rican, Stéphane; Vaillant, Zoé; Roudot, Anna; Meunier-Nikiema, Aude; Kassié, Daouda; Dabiré, Roch K; Salem, Gérard
2016-12-10
Dengue is an emerging infectious disease of global significance. Although this virus has been reported for a long time, its significance within the burden of diseases in West Africa is not obvious, especially in Burkina Faso. Our objective was to evaluate flavivirus presence in Ouagadougou (Burkina Faso) and the link between anti-flavivirus antibody seroprevalence and urbanization modes. A population-based cross-sectional survey was conducted and 3015 children were enrolled from Ouagadougou districts with different types and degrees of urbanization (with/without equipment and high/low building density). Flavivirus (FLAV) IgM MAC-ELISA and FLAV indirect IgG ELISA were performed. Associations between FLAV IgG presence (sign of past infection) and various independent variables were assessed using the chi-square test and a multivariate logistic regression analysis. The apparent prevalence of past flavivirus infections among the enrolled children was 22.7% (95% CI: 22.4-26.7) ( n = 685). Eleven children (0.4%; 95% CI: 0.61-2.14) were positive for FLAV IgM, indicating active transmission. Factors associated with flavivirus infection were identified among the enrolled children (age, sex), householders (educational level, asset index) and in the environment (building density, water access, waste management and house appearance); however, they showed great variability according to the city districts. The water access modality did not significantly influence FLAV IgG positivity. Conversely, apparently good practices of waste management had unexpected consequences (increased risk related to municipal dumpsters). Given the scale of ongoing urbanization and the spread of arboviral diseases, close collaboration between health and city stakeholders is needed.
Nibbering, P H; Van de Gevel, J S; Van Furth, R
1990-07-20
The present study was performed in order to establish whether a cell-ELISA could be used to determine the expression of antigens by adherent murine peritoneal macrophages and also quantify the numbers of such macrophages. Accurate determination of the number of adherent macrophages proved to be possible with a cell-ELISA designed to assess complement receptor type III (CRIII) expression. Expression of CRIII was considerably more sensitive than determination of the cell-protein or DNA content as a measure of the number of adherent macrophages. For the calculation of the expression of CRIII, Ia antigen, and antigen F4/80 by resident and activated macrophages, use was made of the linear part of the curve obtained when the numbers of macrophages were plotted against the absorbance values for each of the antigens. The values for CRIII expression did not differ significantly between resident macrophages, macrophages activated with recombinant interferon-gamma (rIFN-gamma) and macrophages activated with BCG/PPD. IFN-gamma-activated and BCG/PPD-activated macrophages expressed Ia antigen significantly more intensely than did resident peritoneal macrophages. In contrast the activated macrophages expressed F4/80 significantly less intensely than resident peritoneal macrophages.
Minor allergen patterns in birch pollen allergen products-A question of pollen?
Zimmer, J; Döring, S; Strecker, D; Trösemeier, J H; Hanschmann, K M; Führer, F; Vieths, S; Kaul, S
2017-08-01
Contrary to the scientific differentiation between major and minor allergens, the regulatory framework controlling allergen products in the EU distinguishes relevant and non-relevant allergens. Given the lack of knowledge on their clinical relevance, minor allergens are usually not controlled by allergen product specifications. Especially, in birch pollen (BP) allergen products, minor allergens are commonly disregarded. To quantify three minor allergens in BP allergen products from different manufacturers and to assess the influence of the utilized BP on minor allergen patterns. Apart from common quality parameters such as Bet v 1 content, Bet v 4, Bet v 6 and Bet v 7 were quantified in 70 BP allergen product batches from six manufacturers, using ELISA systems developed in-house. Batch-to-batch variability was checked for agreement with a variability margin of 50%-200% from mean of the given batches for individual allergen content. Subsequently, minor allergen patterns were generated via multidimensional scaling and related to information on the pollen lots used in production of the respective product batches. Like the already established Bet v 4 ELISA, the ELISA systems for quantification of Bet v 6 and Bet v 7 were successfully validated. Differences in minor allergen content between products and batch-to-batch consistency were observed. Correlations between minor and major allergen content were low to moderate. About 20% of batches exceeded the variability margin for at least one minor allergen. Interestingly, these fluctuations could not in all cases be linked to the use of certain BP lots. The impact of the observed minor allergen variability on safety and efficacy of BP allergen products can currently not be estimated. As the described differences could only in few cases be related to the used pollen lots, it is evident that additional factors influence minor allergens in BP allergen products. © 2017 John Wiley & Sons Ltd.
Ahn, Junsik; Lee, Kyung Jin
2014-01-01
The purpose of this study is to optimize ELISA conditions to quantify the colorectal cancer antigen GA733 linked to the Fc antibody fragment fused to KDEL, an ER retention motif (GA733-FcK) expressed in transgenic plant. Variable conditions of capture antibody, blocking buffer, and detection antibody for ELISA were optimized with application of leaf extracts from transgenic plant expressing GA733-FcK. In detection antibody, anti-EpCAM/CD362 IgG recognizing the GA733 did not detect any GA733-FcK whereas anti-human Fc IgG recognizing the human Fc existed in plant leaf extracts. For blocking buffer conditions, 3% BSA buffer clearly blocked the plate, compared to the 5% skim-milk buffer. For capture antibody, monoclonal antibody (MAb) CO17-1A was applied to coat the plate with different amounts (1, 0.5, and 0.25 μg/well). Among the amounts of the capture antibody, 1 and 0.5 μg/well (capture antibody) showed similar absorbance, whereas 0.25 μg/well of the capture antibody showed significantly less absorbance. Taken together, the optimized conditions to quantify plant-derived GA733-FcK were 0.5 μg/well of MAb CO17-1A per well for the capture antibody, 3% BSA for blocking buffer, and anti-human Fc conjugated HRP. To confirm the optimized ELISA conditions, correlation analysis was conducted between the quantified amount of GA733-FcK in ELISA and its protein density values of different leaf samples in Western blot. The co-efficient value R2 between the ELISA quantified value and protein density was 0.85 (p<0.01), which indicates that the optimized ELISA conditions feasibly provides quantitative information of GA733-FcK expression in transgenic plant. PMID:24555929
Postel, A; Ziller, M; Rudolf, M; Letzel, T; Ehricht, Ralf; Pourquier, P; Dauber, M; Grund, C; Beer, Martin; Harder, T C
2011-04-01
Avian influenza viruses (AIVs) of the H5 and H7 subtypes can cause substantial economic losses in the poultry industry and are a potential threat to public health. Serosurveillance of poultry populations is an important monitoring tool and can also be used for control of vaccination campaigns. The purpose of this study was to develop broadly reactive, yet subtype-specific competitive ELISAs (cELISAs) for the specific detection of antibodies to the notifiable AIV subtypes H5 and H7 as an alternative to the gold standard haemagglutination inhibition assay (HI). Broadly reacting monoclonal competitor antibodies (mAbs) and genetically engineered subtype H5 or H7 haemagglutinin antigen, expressed and in vivo biotinylated in insect cells, were used to develop the cELISAs. Sera from galliform species and water fowl (n=793) were used to evaluate the performance characteristics of the cELISAs. For the H5 specific cELISA, 98.1% test sensitivity and 91.5% test specificity (97.7% and 90.2% for galliforms; 98.9% and 92.6% for waterfowl), and for the H7 cELISA 97.3% sensitivity and 91.8% specificity (95.3% and 98.9% for galliforms; 100% and 82.7% for waterfowl) were reached when compared to HI. The use of competitor mAbs with broad spectrum reactivity within an AIV haemagglutinin subtype allowed for homogenous detection with high sensitivity of subtype-specific antibodies induced by antigenically widely distinct isolates including antigenic drift variants. However, a trade-off regarding sensitivity versus nonspecific detection of interfering antibodies induced by phylo- and antigenically closely related subtypes, e.g., H5 versus H2 and H7 versus H15, must be considered. The observed intersubtype antibody cross-reactivity remains a disturbance variable in AIV subtype-specific serodiagnosis which negatively affects specificity. Copyright © 2011 Elsevier B.V. All rights reserved.
Chaya, DR; Parija, Subhash Chandra
2013-01-01
Introduction: Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. Materials and Methods: A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. Results: The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. Conclusions: ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE. PMID:24470996
Maruyama, Haruhiko; Kaneko, Michiko; Otake, Taiga; Kano, Rui; Yamaya, Yoshiki; Watari, Toshihiro; Hasegawa, Atsuhiko; Kamata, Hiroshi
2014-03-01
A disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13 (ADAMTS13) is a von Willebrand factor (vWF)-cleaving protease. Deficiencies in ADAMTS13 activity are known to cause thrombotic diseases in human beings. The present study evaluated whether the human ADAMTS13 activity enzyme-linked immunosorbent assay (ELISA) kit containing human vWF73 (a minimal substrate) and anti-N10 antibody (which specifically recognizes the decapeptide of the C-terminal edge of cleaved vWF by human ADAMTS13) is applicable to the measurement of canine plasma ADAMTS13 activity. Human vWF73 fused with a GST-tag and a His-tag (GST-hvWF73-His) was reacted with recombinant canine (rc)ADAMTS13, canine plasma, and human plasma, and then used in Western blotting using anti-N10 antibody. Linearity and intra- and interassay reproducibility of the human ADAMTS13 activity ELISA kit in canine plasma were further evaluated. Finally, plasma ADAMTS13 activity was measured in 13 healthy dogs and 6 dogs with bacteremia using the human ADAMTS13 activity ELISA kit. Cleaved products with a 28-kDa GST-hvWF73-His were detected specifically in rcADAMTS13 as well as in human ADAMTS13, and also in canine plasma by anti-N10 antibody, showing excellent linearity. Intra-assay coefficient of variation (CV) was 3.0-12.4%, and interassay CV was 11.5-12.5%. The ADAMTS13 activity was significantly lower in dogs with bacteremia than in healthy dogs (P = 0.0025). The current study revealed that the human ADAMTS13 activity ELISA kit is applicable for measurement of canine plasma ADAMTS13 activity to elucidate the pathology of thrombotic diseases in dogs.
Zajicek, J.L.; Tillitt, D.E.; Schwartz, T.R.; Schmitt, C.J.; Harrison, R.O.
2000-01-01
The analysis of PCBs in fish tissues by immunoassay methods was evaluated using fish collected from a US monitoring program, the National Contaminant Biomonitoring Program of the US Department of Interior, Fish and Wildlife Service. Selected composite whole fish samples, which represented widely varying concentrations and sources of PCBs, were extracted and subjected to congener PCB analysis by gas chromatography (GC) and total PCB analysis using an ELISA (ePCBs) calibrated against technical Aroclor 1248. PCB congener patterns in these fishes were different from the patterns found in commercial Aroclors or their combinations as demonstrated by principal component analysis of normalized GC congener data. The sum of the PCB congeners measured by GC (total-PCBs) ranged from 37 to 4600 ng/g (wet weight). Concentrations of PCBs as determined by the ELISA method were positively correlated with total-PCBs and the ePCBs/total-PCBs ratios for individual samples ranged from 1 to 6. Ratios of ePCBs/total-PCBs for dilutions of Aroclors 1242, 1254, and 1260 and for matrix spikes range from 0.6 for 1242 to 2.5 for 1254 and 1260. These results suggest that higher chlorinated PCB congeners have higher affinity for the anti-PCB antibodies. Partial least squares with latent variable analysis of GC and ELISA data of selected Aroclors and fish samples also support the conclusion that ELISA derived PCB concentrations are dependent on the degree on chlorination.
2017-01-01
The World Health Organization (WHO) enzyme-linked immunosorbent assay (ELISA) guideline is currently accepted as the gold standard for the evaluation of immunoglobulin G (IgG) antibodies specific to pneumococcal capsular polysaccharide. We conducted validation of the WHO ELISA for 7 pneumococcal serotypes (4, 6B, 9V, 14, 18C, 19F, and 23F) by evaluating its specificity, precision (reproducibility and intermediate precision), accuracy, spiking recovery test, lower limit of quantification (LLOQ), and stability at the Ewha Center for Vaccine Evaluation and Study, Seoul, Korea. We found that the specificity, reproducibility, and intermediate precision were within acceptance ranges (reproducibility, coefficient of variability [CV] ≤ 15%; intermediate precision, CV ≤ 20%) for all serotypes. Comparisons between the provisional assignments of calibration sera and the results from this laboratory showed a high correlation > 94% for all 7 serotypes, supporting the accuracy of the ELISA. The spiking recovery test also fell within an acceptable range. The quantification limit, calculated using the LLOQ, for each of the serotypes was 0.05–0.093 μg/mL. The freeze-thaw stability and the short-term temperature stability were also within an acceptable range. In conclusion, we showed good performance using the standardized WHO ELISA for the evaluation of serotype-specific anti-pneumococcal IgG antibodies; the WHO ELISA can evaluate the immune response against pneumococcal vaccines with consistency and accuracy. PMID:28875600
Lee, Hyunju; Lim, Soo Young; Kim, Kyung Hyo
2017-10-01
The World Health Organization (WHO) enzyme-linked immunosorbent assay (ELISA) guideline is currently accepted as the gold standard for the evaluation of immunoglobulin G (IgG) antibodies specific to pneumococcal capsular polysaccharide. We conducted validation of the WHO ELISA for 7 pneumococcal serotypes (4, 6B, 9V, 14, 18C, 19F, and 23F) by evaluating its specificity, precision (reproducibility and intermediate precision), accuracy, spiking recovery test, lower limit of quantification (LLOQ), and stability at the Ewha Center for Vaccine Evaluation and Study, Seoul, Korea. We found that the specificity, reproducibility, and intermediate precision were within acceptance ranges (reproducibility, coefficient of variability [CV] ≤ 15%; intermediate precision, CV ≤ 20%) for all serotypes. Comparisons between the provisional assignments of calibration sera and the results from this laboratory showed a high correlation > 94% for all 7 serotypes, supporting the accuracy of the ELISA. The spiking recovery test also fell within an acceptable range. The quantification limit, calculated using the LLOQ, for each of the serotypes was 0.05-0.093 μg/mL. The freeze-thaw stability and the short-term temperature stability were also within an acceptable range. In conclusion, we showed good performance using the standardized WHO ELISA for the evaluation of serotype-specific anti-pneumococcal IgG antibodies; the WHO ELISA can evaluate the immune response against pneumococcal vaccines with consistency and accuracy. © 2017 The Korean Academy of Medical Sciences.
Molinari, José L; García-Mendoza, Esperanza; de la Garza, Yazmin; Ramírez, José A; Sotelo, Julio; Tato, Patricia
2002-06-01
To detect IgG antibodies to Taenia solium, a controlled double-blind study was conducted using 91 coded cerebrospinal fluid samples from patients with neurocysticercosis (NCC) and other neurologic disorders. Samples were tested in an enzyme-linked immunosorbent assay (ELISA) using metacestode excretion/secretion antigens. The results were correlated with data from medical records on the diagnosis of NCC (based on computed tomography and magnetic resonance imaging criteria) and other neurologic disorders. The ELISA results were positive in 22 of the 24 cases with active NCC. In contrast, six cases with calcified cysts (inactive NCC), as well as one case in a transitional stage, were negative. One case with a calcified granuloma and another with a granuloma plus calcifications (classified as inactive NCC) had positive results. The remaining negative results corresponded to other neurologic disorders (58 cases). The results of the ELISA showed a significant difference between active and inactive NCC (P = 0.0034).
Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina
2012-05-02
Immunodetection of allergens in dark chocolate is complicated by interference from the chocolate components. The objectives of this study were to establish reference materials for detecting multiple allergens in dark chocolate and to determine the accuracy and precision of allergen detection by enzyme-linked immunosorbent assay (ELISA) before and after chocolate processing. Defatted peanut flour, whole egg powder, and spray-dried milk were added to melted chocolate at seven incurred levels and tempered for 4 h. Allergen concentrations were measured using commercial ELISA kits. Tempering decreased the detection of casein and β-lactoglobulin (BLG), but had no significant effect on the detection of peanut and egg. Total coefficients of variation were higher in tempered than untempered chocolate for casein and BLG, but total and analytical CVs were comparable for peanut and egg. These findings indicate that processing has a greater effect on recovery and variability of casein and BLG than peanut and egg detection in a dark chocolate matrix.
ERIC Educational Resources Information Center
Haussmann, Mark F.; Vleck, Carol M; Farrar, Eugenia S.
2007-01-01
Perceived stress activates the hypothalamus-pituitary-adrenal axis, resulting in the release of glucocorticoids into the systemic circulation. Glucocorticoids cause the elevation of blood glucose, providing the necessary energy for the organism to cope with stress. Here, we outline a laboratory exercise that uses a competitive ELISA kit to…
Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J
2016-01-01
Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive control will benefit inter-laboratory validation of ELISA assays and serve as quality control (QC) reagents for Ov16 RDTs at different points of the supply chain from manufacturer to field use.
Mwanjali, Gloria; Kihamia, Charles; Kakoko, Deodatus Vitalis Conatus; Lekule, Faustin; Ngowi, Helena; Johansen, Maria Vang; Thamsborg, Stig Milan; Willingham, Arve Lee
2013-01-01
Background Taenia solium cysticercosis/taeniosis is emerging as a serious public health and economic problem in many developing countries. This study was conducted to determine prevalence and risk factors of human T. solium infections in Mbeya Region, Tanzania. Methods and Findings A cross-sectional survey was conducted in 13 villages of Mbozi district in 2009. Sera of 830 people (mean 37.9±11.3 years (SD); 43% females) were tested for circulating cysticerci antigen (Ag-ELISA) and antibody (Ab-ELISA). A subset of persons found seropositive by Ag-ELISA underwent computed tomography (CT) scan of the brain for evidence of neurocysticercosis. Stool samples from 820 of the same participants were tested for taeniosis by copro-antigens (copro-Ag-ELISA) and formol-ether concentration technique. Cases of T. solium taeniosis were confirmed serologically by EITB assay (rES38). A questionnaire was used for identification of risk factors. Active cysticercosis by positive Ag-ELISA was found in 139 (16.7%) persons while anti-cysticercal antibodies were detected in 376 (45.3%) persons by Ab-ELISA. Among 55 persons positive for Ag-ELISA undergoing CT scan, 30 (54.6%) were found to have structures in the brain suggestive of neurocysticercosis. Using faecal analysis, 43 (5.2%) stool samples tested positive for taeniosis by copro-Ag-ELISA while Taenia eggs were detected in 9 (1.1%) stool samples by routine coprology. Antibodies specifically against adult T. solium were detected in 34 copro-Ag-ELISA positive participants by EITB (rES38) indicating T. solium taeniosis prevalence of 4.1%. Increasing age and hand washing by dipping in contrast to using running water, were found associated with Ag-ELISA seropositivity by logistic regression. Gender (higher risk in females) and water source were risk factors associated with Ab-ELISA seropositivity. Reported symptoms of chronic severe headaches and history of epileptic seizures were found associated with positive Ag-ELISA (p≤0.05). Conclusion The present study indicates T. solium infection in humans is highly endemic in the southern highlands of Tanzania. PMID:23516650
Andrejevic, Sladjana; Jeremic, Ivica; Sefik-Bukilica, Mirjana; Nikolic, Milos; Stojimirovic, Biljana; Bonaci-Nikolic, Branka
2013-11-01
We assessed the relationship between the serum levels of antibodies against double-stranded DNA (dsDNA), C1q, nucleosomes, histones, C3 and C4 complement components with one another, with organ involvement and overall disease activity in patients with systemic lupus erythematosus (SLE). One hundred seventy-five sera from 99 patients with SLE, 31 sera of patients with other connective tissue diseases, and 20 sera from healthy blood donors were tested. SLE disease activity was assessed by modified SLEDAI-2K (M-SLEDAI-2K), not including complement and anti-dsDNA descriptors. Anti-dsDNA antibodies were measured by indirect immunofluorescence on Crithidia luciliae (CLIFT), standard enzyme-linked immunosorbent assay (ELISA) and ELISA for high-avidity antibodies. The most significant risk factor for renal involvement were anti-C1q antibodies (OR = 3.88, p < 0.05), high-avidity anti-dsDNA antibodies for polyserositis (OR = 7.99, p < 0.01), anti-histone antibodies for joint involvement (OR = 2.75, p < 0.05), and low C3 for cytopenia (OR = 11.96, p < 0.001) and mucocutaneous lesions (OR = 3.32, p < 0.01). Multiple linear regression analysis showed that disease activity in SLE could be predicted by the levels of antibodies against dsDNA determined by standard (p < 0.05) and high-avidity (p < 0.001) ELISA, and inversely associated with concentration of C3 (p < 0.001). Using stepwise method, high-avidity anti-dsDNA antibodies were found to be in the closest association to M-SLEDAI-2K. Moreover, positive test for high-avidity anti-dsDNA antibodies appeared as an independent risk factor for moderately to severely active disease (M-SLEDAI-2K>5) (OR = 5.5, p < 0.01). The presence of high-avidity anti-dsDNA antibodies represented a risk for renal, joint, and most importantly for serosal involvement. Our results suggest that simple and reliable ELISA for high-avidity anti-dsDNA antibodies is the test of good clinical utility for the assessment of global SLE activity.
Screening of a ScFv Antibody With High Affinity for Application in Human IFN-γ Immunoassay
Yang, Hang; Zhong, Yanfang; Wang, Juncheng; Zhang, Qinghong; Li, Xiulan; Ling, Sumei; Wang, Shihua; Wang, Rongzhi
2018-01-01
Interferon gamma (IFN-γ), a signal proinflammatory cytokine secreted by immune cell, and plays a critical role in the pathogenesis and progression of many diseases. It has been regarded as an important marker for determination of disease-specific immune responses. Therefore, it is urgent to develop a feasible and accurate method to detect IFN-γ in clinic real blood samples. Until now, the immunoassay based on singe chain variable fragment (scFv) antibody for human IFN-γ is still not reported. In the present study, an scFv antibody named scFv-A8 with high specificity was obtained by phage display and biopanning, with the affinity 2.6 × 109 L/mol. Maltose binding protein (MBP) was used to improve the solubility of scFv by inserting an linker DNA between scFv and MBP tag, and the resulted fusion protein (MBP-LK-scFv) has high solubility and antigen biding activity. The expressed and purified MBP-LK-scFv antibody was used to develop the indirect competitive enzyme-linked immunosorbent assay (ELISA) (ic-ELISA) for detection of human IFN-γ, and the result indicated that the linear range to detect IFN-γ was 6–60 pg/mL with IC50 of 25 pg/mL. The limit of detection was 2 pg/mL (1.3 fm), and the average recovery was 85.05%, further demonstrating that the detection method based on scFv has higher recovery and accuracy. Hence, the developed ic-ELISA can be used to detect IFN-γ in real samples, and it may be further provided a scientific basis for disease diagnosis. PMID:29563896
Studentsov, Yevgeniy Y.; Schiffman, Mark; Strickler, Howard D.; Ho, Gloria Y. F.; Pang, Yuk-Ying Susana; Schiller, John; Herrero, Rolando; Burk, Robert D.
2002-01-01
Measurement of antibodies to human papillomavirus (HPV) is complicated by many factors. Although enzyme-linked immunosorbent assays (ELISAs) that use virus-like particles (VLPs) have proved useful, the assays have, in general, had moderate sensitivities and low signal-to-noise ratios. To enhance the performance of the assay, a systematic investigation was undertaken to examine key variables used in ELISAs for the detection of antibodies to VLPs of HPV. Incorporation of two vinyl polymers, polyvinyl alcohol (molecular weight, 50,000) (PVA-50) and polyvinylpyrrolidone (molecular weight, 360,000) (PVP-360), was found to increase the sensitivity as well as the specificity of the assay for the detection of antibodies to VLPs of HPV. In particular, the addition of PVA-50 to the blocking solution reduced the amount of nonspecific binding of antibodies to VLPs and the microplate surface, whereas the addition of PVP-360 increased the sensitivity of antibody detection. The new ELISA demonstrated increased sensitivity and specificity for the detection of cervical HPV type 16 infection compared to those of a prototype assay with coded clinical serum samples from women with known cervicovaginal HPV infection status. It is anticipated that the enhanced ELISA conditions will have wide application to a large number of clinical diagnostic assays. PMID:11980956
NASA Astrophysics Data System (ADS)
Hosseini, Samira; Ibrahim, Fatimah; Djordjevic, Ivan; Rothan, Hussin A.; Yusof, Rohana; van der Marel, Cees; Koole, Leo H.
2014-10-01
Despite the known drawbacks of enzyme-linked immunosorbent assay (ELISA), one of the deficiencies that have relatively been ignored is the performance of ELISA substrate itself. Polystyrene (PS), as the cost effective material of choice for mass production of ELISA well-plates, has shown obvious lacks of suitable physical and chemical properties for protein attachment. The general concept of this work was to develop a potential substrate that can be suggested as a material of choice for production of a new generation of ELISA analytical kits. Spin-coated thin films of polymethyl methacrylate-co-methacrylic acid (PMMA-co-MAA) on silicon surfaces were designed and processed for detection of dengue virus. Coated surfaces of different molar ratios have been investigated as carboxyl-functionalized layers for obtaining platform for biomolecule immobilization with high level of protein activity. To improve the sensitivity of detection, we have used amine functional "spacers", hexamethylenediamine (HMDA) and polyethyleneimine (PEI), which were covalently bonded to the surfaces of PMMA-co-MAA coatings. Results demonstrate that the variation of surface concentration of carboxyl groups of PMMA-co-MAA can be used to control the amine surface concentration after carbodiimide coupling with HMDA and PEI spacers. The presence of amine spacers increases hydrophilicity of the coatings and significantly impacts the polymer surface morphology. In particular, protein immobilization via amine-bearing spacers has been achieved in two effective steps: (1) carbodiimide bonding between amine spacer molecules and PMMA-co-MAA polymer coatings; and (2) covalent immobilization of antibody via glutaraldehyde reaction with amine groups from amine-treated surfaces. The application of PEI spacer in comparison to HMDA has shown much higher intensity of detection signal in ELISA experiment, indicating better immobilization efficiency and preservation of antibody activity upon attachment to the polymer surface.
Yeargan, Michelle; de Assis Rocha, Izabela; Morrow, Jennifer; Graves, Amy; Reed, Stephen M; Howe, Daniel K
2015-05-01
Enzyme-linked immunosorbent assays (ELISAs) based on the SnSAG surface antigens of Sarcocystis neurona provide reliable detection of infection by the parasite. Moreover, accurate serodiagnosis of equine protozoal myeloencephalitis (EPM) is achieved with the SnSAG ELISAs by measuring antibodies in serum and cerebrospinal fluid (CSF) to reveal active infection in the central nervous system. Two independent ELISAs based on recombinant (r)SnSAG2 or a chimeric fusion of SnSAG3 and SnSAG4 (rSnSAG4/3) are currently used together for EPM serodiagnosis to overcome varied antibody responses in different horses. To achieve reliable antibody detection with a single ELISA instead of 2 separate ELISAs, rSnSAG2 was fused with rSnSAG4/3 into a single trivalent protein, designated rSnSAG2/4/3. Paired serum and CSF from 163 horses were tested with all 3 ELISAs. When the consensus antibody titers obtained with the rSnSAG2 and rSnSAG4/3 ELISAs were compared to the single SAG2/4/3 ELISA titers, Spearman rank correlation coefficients of ρ = 0.74 and ρ = 0.90 were obtained for serum and CSF, respectively, indicating strong agreement between the tests. When the rSnSAG2 and rSnSAG4/3 consensus serum-to-CSF titer ratio was compared to the rSnSAG2/4/3 serum-to-CSF titer ratio, the Spearman correlation coefficient was ρ = 0.87, again signifying strong agreement. Importantly, comparing the diagnostic interpretation of the serum-to-CSF titer ratios yielded a Cohen kappa value of 0.77. These findings suggest that the single ELISA based on the trivalent rSnSAG2/4/3 will provide serologic and diagnostic results that are highly comparable to the consensus of the 2 independent ELISAs based on rSnSAG2 and rSnSAG4/3. © 2015 The Author(s).
Palusiak, Agata; Dzieciatkowska, Monika; Sidorczyk, Zygmunt
2008-01-01
Proteus penneri lipopolysaccharide (LPS) core regions are characterized by a greater structural variability than that observed in other Enterobacteriaceae. This fact and the small amount of published data concerning the serological activity of this part of P. penneri LPS prompted an examination of which fragment might determine cross-reactions with antibodies. To date, such epitopes have been found in the LPS core regions of P. mirabilis and P. vulgaris strains. Proteus sp. LPSs were tested with unabsorbed rabbit antisera by enzyme-linked immunosorbent assay (ELISA), sodium dodecyl sulfate polyacrylamide gel electrophoresis and Western blot, and once again by ELISA or passive immunohemolysis after the absorption of these antisera with selected LPSs. The serological studies of P. penneri 8 LPS demonstrated antibodies in the tested antisera recognizing a common epitope located in the core regions of six of the LPSs, i.e. P. penneri 8, 34, 133, 7, 14, and 15. Additionally, another type of antibody directed against some fragment of P. penneri 13 and the core regions of other LPSs investigated was observed in one antiserum. A distal, trisaccharide fragment of the P. penneri 8 LPS core region is suggested to determine the cross-reactions of the tested antisera with the six P. penneri LPSs.
2004 National Atrazine Occurrence Monitoring Program using the Abraxis ELISA method.
Graziano, Nicole; McGuire, Michael J; Roberson, Alan; Adams, Craig; Jiang, Hua; Blute, Nicole
2006-02-15
The goal of this project was to gain a better understanding of atrazine occurrence in the United States by surveying drinking water utilities' sources and finished water for atrazine on a weekly basis for seven months. Atrazine is a contaminant of interest because the United States Environmental Protection Agency (USEPA) has found short-term atrazine exposure above the drinking water maximum contaminant level (MCL) to potentially cause heart, lung, and kidney congestion, low blood pressure, muscle spasms, weight loss, and damage to the adrenal glands. Long-term exposure to atrazine concentrations above the drinking water MCL has been linked to weight loss, cardiovascular damage, retinal and muscle degeneration, and cancer. This survey effort improved upon previously conducted atrazine surveys through intensive, high frequency sampling (participating plants sampled their raw and finished water on a weekly basis for approximately seven months). Such an intensive effort allowed the authors to gain a better understanding of short-term atrazine occurrence and its variability in drinking water sources. This information can benefit the drinking water industry by facilitating (1) better atrazine occurrence management (i.e., awareness when plants may be more susceptible to atrazine), (2) more efficient atrazine control (e.g., effective treatment alternatives and more effective response to atrazine occurrence), and (3) treatment cost reduction (e.g., efficient atrazine control can result in substantial cost savings). Forty-seven drinking watertreatment plants located primarily in the Midwestern United States participated in the survey and sampled their raw and finished water on a weekly basis from March through October. Samples were analyzed using the Abraxis enzyme-linked immunosorbent assay (ELISA) test kit. Confirmation samples for quality assurance/quality control (QA/QC) purposes were analyzed using solid-phase extraction (SPE) followed by gas chromatography mass spectrophotometry (GC/MS). Several important conclusions can be drawn from this study including (1) surface waters were confirmed to be more vulnerable to atrazine contamination than groundwater sources, (2) peak atrazine concentrations corresponded well to precipitation/runoff events, and (3) atrazine occurrence tended to be uniform geographically when compared by river drainage basins. In addition, this project confirmed that the Abraxis atrazine ELISA test kit tended to have a positive bias (i.e., the measured ELISA concentration was higher than the actual concentration) in most measured samples. Finished samples tended to have more of a positive bias than raw water samples. Therefore, this bias may limit the effectiveness for ELISA for regulatory monitoring. There are many other applications for ELISA, however, including frequent monitoring for early detections of atrazine concentration changes that might trigger conventional analysis by GC/MS or be used for activated carbon dosing or other treatment operating controls.
Accuracy of five serologic tests for the follow up of Strongyloides stercoralis infection.
Buonfrate, Dora; Sequi, Marco; Mejia, Rojelio; Cimino, Ruben O; Krolewiecki, Alejandro J; Albonico, Marco; Degani, Monica; Tais, Stefano; Angheben, Andrea; Requena-Mendez, Ana; Muñoz, José; Nutman, Thomas B; Bisoffi, Zeno
2015-02-01
Traditional faecal-based methods have poor sensitivity for the detection of S. stercoralis, therefore are inadequate for post-treatment evaluation of infected patients who should be carefully monitored to exclude the persistence of the infection. In a previous study, we demonstrated high accuracy of five serology tests for the screening and diagnosis of strongyloidiasis. Aim of this study is to evaluate the performance of the same five tests for the follow up of patients infected with S. stercoralis. Retrospective study on anonymized, cryo-preserved samples available at the Centre for Tropical Diseases (Negrar, Verona, Italy). Samples were collected before and from 3 to 12 months after treatment. The samples were tested with two commercially-available ELISA tests (IVD, Bordier), two techniques based on a recombinant antigen (NIE-ELISA and NIE-LIPS) and one in-house IFAT. The results of each test were evaluated both in relation to the results of fecal examination and to those of a composite reference standard (classifying as positive a sample with positive stools and/or at least three positive serology tests). The associations between the independent variables age and time and the dependent variable value of serological test (for all five tests), were analyzed by linear mixed-effects regression model. A high proportion of samples demonstrated for each test a seroreversion or a relevant decline (optical density/relative light units halved or decrease of at least two titers for IFAT) at follow up, results confirmed by the linear mixed effects model that showed a trend to seroreversion over time for all tests. In particular, IVD-ELISA (almost 90% samples demonstrated relevant decline) and IFAT (almost 87%) had the best performance. Considering only samples with a complete negativization, NIE-ELISA showed the best performance (72.5% seroreversion). Serology is useful for the follow up of patients infected with S. stercoralis and determining test of cure.
Kidd, J A; Ross, P; Buntzman, A S; Hess, P R
2015-06-01
Resistance to Escherichia coli l-asparaginase in canine lymphoma occurs frequently with repeated administration, a phenomenon often attributed, without substantiation, to the induction of neutralizing antibodies. To test the hypothesis that treated dogs develop antibodies against the drug, we created an enzyme-linked immunosorbent assay (ELISA) to measure plasma anti-asparaginase immunoglobulin G responses. Using samples from dogs that had received multiple doses, specific reactivity against l-asparaginase was demonstrated, while naïve patients' samples were negative. The optimized ELISA appeared sensitive, with endpoint titers >1 600 000 in positive control dogs. Intra- and inter-assay coefficients of variation were 3.6 and 14.5%. The assay was supported by the observation that ELISA-positive plasma could immunoprecipitate asparaginase activity. When clinical patients were evaluated, 3/10 dogs developed titers after a single injection; with repeated administration, 4/7 dogs were positive. l-asparaginase antibodies showed reduced binding to the PEGylated drug formulation. The ELISA should prove useful in investigating the potential correlation of antibody responses with resistance. © 2012 Blackwell Publishing Ltd.
Kidd, Jason A.; Ross, Peter; Buntzman, Adam S.; Hess, Paul R.
2012-01-01
Resistance to E. coli L-asparaginase in canine lymphoma occurs frequently with repeated administration, a phenomenon often attributed, without substantiation, to the induction of neutralizing antibodies. To test the hypothesis that treated dogs develop antibodies against the drug, we created an ELISA to measure plasma anti-asparaginase IgG responses. Using samples from dogs that had received multiple doses, specific reactivity against L-asparaginase was demonstrated, while naïve patients’ samples were negative. The optimized ELISA appeared sensitive, with endpoint titers >1,600,000 in positive control dogs. Intra- and inter-assay coefficients of variation were 3.6 and 14.5%. The assay was supported by the observation that ELISA-positive plasma could immunoprecipitate asparaginase activity. When clinical patients were evaluated, 3/10 dogs developed titers after a single injection; with repeated administration, 4/7 dogs were positive. L-asparaginase antibodies showed reduced binding to the PEGylated drug formulation. The ELISA should prove useful in investigating the potential correlation of antibody responses with resistance. PMID:23253146
Fournet, Florence; Rican, Stéphane; Vaillant, Zoé; Roudot, Anna; Meunier-Nikiema, Aude; Kassié, Daouda; Dabiré, Roch K.; Salem, Gérard
2016-01-01
Dengue is an emerging infectious disease of global significance. Although this virus has been reported for a long time, its significance within the burden of diseases in West Africa is not obvious, especially in Burkina Faso. Our objective was to evaluate flavivirus presence in Ouagadougou (Burkina Faso) and the link between anti-flavivirus antibody seroprevalence and urbanization modes. A population-based cross-sectional survey was conducted and 3015 children were enrolled from Ouagadougou districts with different types and degrees of urbanization (with/without equipment and high/low building density). Flavivirus (FLAV) IgM MAC-ELISA and FLAV indirect IgG ELISA were performed. Associations between FLAV IgG presence (sign of past infection) and various independent variables were assessed using the chi-square test and a multivariate logistic regression analysis. The apparent prevalence of past flavivirus infections among the enrolled children was 22.7% (95% CI: 22.4–26.7) (n = 685). Eleven children (0.4%; 95% CI: 0.61–2.14) were positive for FLAV IgM, indicating active transmission. Factors associated with flavivirus infection were identified among the enrolled children (age, sex), householders (educational level, asset index) and in the environment (building density, water access, waste management and house appearance); however, they showed great variability according to the city districts. The water access modality did not significantly influence FLAV IgG positivity. Conversely, apparently good practices of waste management had unexpected consequences (increased risk related to municipal dumpsters). Given the scale of ongoing urbanization and the spread of arboviral diseases, close collaboration between health and city stakeholders is needed. PMID:27973402
Mart'ianov, Andrey A; Dzantiev, Boris B; Zherdev, Anatoly V; Eremin, Sergei A; Cespedes, Raquel; Petrovic, Mira; Barcelo, Damia
2005-01-30
Immunoenzyme assay (ELISA) is proposed and characterized for determination of alkylphenol ethoxylates, a primary class of manufactured non-ionic surfactants. The assay is based on the obtained polyclonal antibodies against nonylphenol (NP), the main stable intermediate of the decomposition of nonylphenol ethoxylates. A mixture of non-modified branched isomers of NP was applied as hapten coupled to protein carriers by Mannich reaction with the use of formaldehyde. The proposed ELISA format is based on immobilized NP-(soybean trypsin inhibitor) conjugate as a competitor of antigen molecules contained in the tested sample for binding with specific antibodies indirectly labeled via an anti-species immunoperoxidase conjugate. The developed ELISA allows to reveal NP with the limit of detection about 10ngml(-1) and NP-related compounds such as octylphenol, alkylphenoletoxylates, alkylphenolcarboxylates and their halogenated derivatives. The ELISA was applied for assaying polluted water samples, namely influents and effluents from different wastewater treatment plants (WWTP) and tap water. ELISA and chromatographic data demonstrate good correlation (r = 0.94), while ELISA gives higher values. Due to endocrine disrupting and other toxic activities of some metabolites of alkylphenolic non-ionic surfactants, the developed assay may be effectively used in ecological monitoring and sanitary control.
Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann
2018-03-01
This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.
Dagenais, P; Desprez, B; Albert, J; Escher, E
1994-10-01
Direct adsorption of small peptide antigens to unaltered, commercially available polystyrene surfaces may be too weak to permit suitable assay by ELISA. We therefore developed a simple method for the covalent attachment of small, potentially single epitope antigens to polystyrene surfaces. Chemical activation of polystyrene plates with carbodiimide considerably improves the total and covalent attachment of radioactive octapeptides. The covalent attachment was demonstrated by washing with hot detergent. A 3.5 Mrad gamma-irradiation of plates also increases total binding, particularly in combination with chemical activation. The covalent attachment presumably occurs through formation and chemical activation of carboxylate functions on the polystyrene surface which form amide bonds with peptides. ELISA test was performed with CGRP and successive smaller CGRP fragments. Covalent attachment of C-terminal peptide fragments as detection antigens allows optimal recognition and sensitivity even for hexapeptides, while decapeptide antigens were already poorly recognized using a conventional antigen plating technique. Repetitive detergent washes and/or prolonged storage of plates with covalently bound antigens did not reduce their ELISA sensitivity. The method with storage and reutilization capacities that we present here will be useful for the development of preplated antibody screening test.
Bovine herpesvirus 1: within-herd seroprevalence and antibody levels in bulk-tank milk.
Martínez, S; Yus, E; Sanjuán, M L; Camino, F; Eiras, M C; Arnaiz, I; Diéguez, F J
2016-12-01
The aim of the present study was to establish a relationship between the results obtained with the enzyme-linked immunosorbent assay (ELISA) technique for antibodies (against bovine herpesvirus 1) in serum and those in milk at the herd level. For this purpose, 275 samples of bulk-tank milk were analysed with glycoprotein E (gE) antibody ELISA and 207 more were analysed with glycoprotein B (gB) antibody ELISA (482 in total). All of these samples came from dairy herds whose seroprevalence was also evaluated. The results of this study were then used to analyse the sensitivity of the bulk-tankmilk test in detecting herds with a high risk of active infection (>60% seroprevalence) and its specificity in detecting those with few (<20%) or no seropositive animals. In regard to the reference test (results in blood serum), the sensitivity of the bulk-tankmilk test in detecting herds with >60% seropositive animals was 100% for both gE and gB ELISAs. The specificity figures, for gE and gB ELISAs, respectively, were 88.4% and 99.1% for infection-free herds and 72.6% and 96% for herds with <20% seroprevalence. In a quantitative approach, Pearson's correlation coefficients, reported as a measure of linear association between herd seroprevalences and transformed optical density values recorded in bulk-tank milk, were -0.63 for gE ELISA and 0.67 for gB ELISA. © OIE (World Organisation for Animal Health), 2016.
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
2012-01-01
Background Contagious agalactia (CA) of sheep and goats caused by Mycoplasma agalactiae is a widely occurring economically important disease that is difficult to control. The ELISA is commonly used for the serological detection of CA but it has some limitations and the performance of the available tests have not been properly evaluated. Two commercial ELISA kits are widely used, one involving a fusion protein as target antigen and the other a total antigen. The objectives were to compare these tests by evaluating: i. Their diagnostic sensitivity and specificity, the relevance of the recommended cut-off points, the correlation between the two tests, and, the correlation between serology data and the milk shedding of M. agalatiae; ii. The influence of extrinsic factors such as the targeted animal species, geographical origin of the samples, intra-specific variability of M. agalactiae and concurrent mycoplasma infections. A sample of 5900 animals from 211 farms with continuous CA monitoring for 20 years and no prior vaccination history was used. The infection status was known from prior bacteriological, epidemiological and serological monitoring with a complementary immunoblotting test. Results The average diagnostic sensitivity was 56% [51.8–59.8] for the fusion protein ELISA and 84% [81.3–87.2] for the total antigen ELISA, with noteworthy flock-related variations. The average diagnostic specificity for the fusion protein ELISA was 100% [99.9–100], and for the total antigen ELISA differed significantly between goats and sheep: 99.3% [97.4–99.9] and 95.7% [93.8–97.2] respectively. Experimental inoculations with different M. agalactiae strains revealed that the ELISA kits poorly detected the antibody response to certain strains. Furthermore, test performances varied according to the host species or geographical origin of the samples. Finally, the correlation between milk shedding of M. agalactiae and the presence of detectable antibodies in the blood was poor. Conclusions These serological tests are not interchangeable. The choice of a test will depend on the objectives (early detection of infection or disease control program), on the prevalence of infection and the control protocol used. Given the variety of factors that may influence performance, a preliminary assessment of the test in a given situation is recommended prior to widespread use. PMID:22776779
Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R
2004-04-01
A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.
Prospective Study of Serologic Tests for Lyme Disease
Steere, Allen C.; McHugh, Gail; Damle, Nitin; Sikand, Vijay K.
2017-01-01
Background Tests to determine serum antibody levels—the 2-tier sonicate immunoglobulin M (IgM) and immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) and Western blot method or the IgG of the variable major protein-like sequence-expressed (VlsE) sixth invariant region (C6) peptide ELISA method—are the major tests available for support of the diagnosis of Lyme disease. However, these tests have not been assessed prospectively. Methods We used these tests prospectively to determine serologic responses in 134 patients with various manifestations of Lyme disease, 89 patients with other illnesses (with or without a history of Lyme disease), and 136 healthy subjects from areas of endemicity and areas in which the infection was not endemic. Results With 2-tier tests and the C6 peptide ELISA, only approximately one-third of 76 patients with erythema migrans had results that were positive for IgM or IgG seroreactivity with Borrelia burgdorferi in acute-phase samples. During convalescence, 3–4 weeks later, almost two-thirds of patients had seroreactivity with the spirochete B. burgdorferi. The frequencies of seroreactivity were significantly greater among patients with spirochetal dissemination than they were among those who lacked evidence of disseminated disease. Of the 44 patients with Lyme disease who had neurologic, heart, or joint involvement, all had positive C6 peptide ELISA results, 42 had IgG responses with 2-tier tests, and 2 patients with facial palsy had only IgM responses. However, among the control groups, the IgG Western blot was slightly more specific than the C6 peptide ELISA. The differences between the 2 test systems (2-tier testing and C6 peptide ELISA) with respect to sensitivity and specificity were not statistically significant. Conclusions Except in patients with erythema migrans, both test systems were sensitive for support of the diagnosis of Lyme disease. However, with current methods, 2-tier testing was associated with slightly better specificity. PMID:18532885
A two-site ELISA can quantify upregulation of SMN protein by drugs for spinal muscular atrophy.
Nguyen thi Man; Humphrey, E; Lam, L T; Fuller, H R; Lynch, T A; Sewry, C A; Goodwin, P R; Mackenzie, A E; Morris, G E
2008-11-25
Spinal muscular atrophy (SMA) is an autosomal recessive disorder characterized by loss of lower motor neurons during early or postnatal development. Severity is variable and is inversely related to the levels of survival of motor neurons (SMN) protein. The aim of this study was to produce a two-site ELISA capable of measuring both the low, basal levels of SMN protein in cell cultures from patients with severe SMA and small increases in these levels after treatment of cells with drugs. A monoclonal antibody against recombinant SMN, MANSMA1, was selected for capture of SMN onto microtiter plates. A selected rabbit antiserum against refolded recombinant SMN was used for detection of the captured SMN. The ratio of SMN levels in control fibroblasts to levels in SMA fibroblasts was greater than 3.0, consistent with Western blot data. The limit of detection was 0.13 ng/mL and SMN could be measured in human NT-2 neuronal precursor cells grown in 96-well culture plates (3 x 10(4) cells per well). Increases in SMN levels of 50% were demonstrable by ELISA after 24 hours treatment of 10(5) SMA fibroblasts with valproate or phenylbutyrate. A rapid and specific two-site, 96-well ELISA assay, available in kit format, can now quantify the effects of drugs on survival of motor neurons protein levels in cell cultures.
Gurbuz, Yunus; Ozturk, Baris; Tutuncu, Emin Ediz; Sencan, Irfan; Cicek Senturk, Gonul; Altay, Fatma Aybala
2015-01-01
Background: Crimean-Congo hemorrhagic fever (CCHF) is a widespread disease in Turkey, and was responsible for many deaths in endemic regions during the last decade. The pathogenesis of the disease is not fully understood yet. Objectives: In this study we aimed to determine the levels of tissue plasminogen activator (tPA) and Plasminogen activator inhibitor-1 (PAI-1) as predictors of prognosis in CCHF. Patients and Methods: Patients who were diagnosed by the polymerase chain reaction (PCR) and IgM positivity in the reference laboratory were included in this study. Tissue Plasminogen activator and PAI-1 levels were measured by the enzyme linked immunosorbent assay (ELISA) using a commercial kit (human t-PA ELISA and human PAL-1 ELISA; BioVendor research and diagnostic products, BioVendor-Laboratorni medicina a.s., Brno, Czech Republic). Results: A total of 46 patients participated in this study. The significant differences between recovering patients and the patients who died, regarding Aspartate aminotransferase (AST), Creatine Phosphokinase (CPK), Lactate Dehydrogenase (LDH), Prothrombin Time (PT), activated Partial Thromboplastin time (aPTT), and thrombocyte and fibrinogen levels, were consistent with many clinical studies in the literature. The fatal cases were found to have higher tPA and PAI-1 levels in contrast to the patients who completely recovered. Conclusions: We think that these findings may help the progress of understanding of CCHF pathogenesis. PMID:26587219
Trindade, Mirta; Nording, Malin; Nichkova, Mikaela; Spinnel, Erik; Haglund, Peter; Last, Michael S.; Gee, Shirley; Hammock, Bruce; Last, Jerold A.; González-Sapienza, Gualberto; Brena, Beatriz M.
2010-01-01
Uncontrolled combustion due to garbage recycling is a widespread activity among slum dwellers in distressed economy countries and has been indicated as a major source of dioxin contamination. However, because of the high cost and complexity of gas chromatography/high-resolution mass spectrometry (GC-HRMS) analysis, the magnitude of the problem remains largely unknown. The present study describes a first approach toward the use of a dioxin antibody-based enzyme-linked immunosorbent assay (ELISA) as the basis for a sustainable, simple, and low-cost monitoring program to assess the toxicological impact of uncontrolled combustion in slums. A panel of 16 samples was analyzed by GC-HRMS and ELISA on split extracts. Close to 20% of the analyzed samples showed dioxin concentrations up to almost twice the guidance level for residential soil in several countries, pointing out the need for performing a large-scale monitoring program. Despite the potential for variations in dioxin congener distribution due to the mixed nature of the incinerated material, there was a good correlation between the toxic equivalents as determined by GC-HRMS and ELISA. Furthermore, an interlaboratory ELISA validation showed that the capacity to perform the dioxin ELISA was successfully transferred between laboratories. It was concluded that the ELISA method performed very well as a screening tool to prioritize samples for instrumental analysis, which allows cutting down costs significantly. PMID:18522475
Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao
2016-01-01
The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings.
Feng, Xia; Ma, Jun-Wu; Sun, Shi-Qi; Guo, Hui-Chen; Yang, Ya-Min; Jin, Ye; Zhou, Guang-Qing; He, Ji-Jun; Guo, Jian-Hong; Qi, Shu-yun; Lin, Mi; Cai, Hu; Liu, Xiang-Tao
2016-01-01
The efficacy of an inactivated foot-and-mouth disease (FMD) vaccine is mainly dependent on the integrity of the foot-and-mouth disease virus (FMDV) particles. At present, the standard method to quantify the active component, the 146S antigen, of FMD vaccines is sucrose density gradient (SDG) analysis. However, this method is highly operator dependent and difficult to automate. In contrast, the enzyme-linked immunosorbent assay (ELISA) is a time-saving technique that provides greater simplicity and sensitivity. To establish a valid method to detect and quantify the 146S antigen of a serotype O FMD vaccine, a double-antibody sandwich (DAS) ELISA was compared with an SDG analysis. The DAS ELISA was highly correlated with the SDG method (R2 = 0.9215, P<0.01). In contrast to the SDG method, the DAS ELISA was rapid, robust, repeatable and highly sensitive, with a minimum quantification limit of 0.06 μg/mL. This method can be used to determine the effective antigen yields in inactivated vaccines and thus represents an alternative for assessing the potency of FMD vaccines in vitro. But it still needs to be prospectively validated by analyzing a new vaccine preparation and determining the proper protective dose followed by an in vivo vaccination-challenge study to confirm the ELISA findings. PMID:26930597
Pathak, Ajay D; Dubal, Zunjar B; Doijad, Swapnil; Raorane, Abhay; Rodrigues, Savio; Naik, Rajeshwar; Naik-Gaonkar, Shraddha; Kalorey, Dewanand R; Kurkure, Nitin V; Naik, Rajesh; Barbuddhe, Sukhadeo B
2014-01-01
Brucellosis is a widespread zoonotic infection. This disease is endemic in many parts of Asia, including India. Brucellosis is a major cause of pyrexia of unknown origin (PUO). Persons exposed to infected animals or contaminated animal products are at high risk. Seropositivity among animal handlers, veterinarians and dairy workers has been documented in India. Thus, the present study was aimed to determine prevalence of brucellosis among PUO cases and occupationally exposed individuals. In this study, serum samples (n=282) from cases of pyrexia of unknown origin (PUO) (n=243), and occupationally exposed individuals (n=39) were collected and tested for brucellosis by Rose Bengal plate test (RBPT), serum agglutination test (SAT), indirect ELISA, IgG and IgM ELISA. Blood culture for isolation of Brucella was performed for 10 serologically positive patients using BACTEC 9050 automated blood culture system. Biochemical tests and PCR techniques were used for confirmation of the isolates. Of the samples tested, 4.25%, 3.54%, 6.02% and 4.96% samples were positive by RBPT, SAT, indirect ELISA and IgG ELISA, respectively. None of the sample was positive for IgM ELISA. Of the 10 blood samples cultured bacteriologically, one Brucella isolate was recovered. The isolate was confirmed as Brucella abortus. Amplification of the bcsp31 and IS711 genes was also observed. Seropositivity for brucellosis was observed among PUO cases, animal handlers and dairy workers in Goa, India. The serological tests showed variable results. One Brucella isolate was obtained by performing blood culture. Confirmation of the case was done rapidly using molecular tools. General awareness about clinical symptoms should be increased which will improve proper diagnosis within short time frame.
Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth
2018-06-01
The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.
Development of an anti-dengue NS1 IgG ELISA to evaluate exposure to dengue virus.
Nascimento, Eduardo J M; George, James K; Velasco, Melissa; Bonaparte, Matthew I; Zheng, Lingyi; DiazGranados, Carlos A; Marques, Ernesto T A; Huleatt, James W
2018-07-01
Dengue virus infection elicits immune responses to multiple viral antigens including antibodies to dengue non-structural protein 1 (NS1) which are rapidly induced and detected within days of infection. The recombinant, live, attenuated, tetravalent dengue vaccine (CYD-TDV; Sanofi Pasteur) uses the yellow fever vaccine virus as a back-bone but expresses dengue virus pre-membrane and envelop proteins. Since CYD-TDV does not express dengue NS1, we evaluated the utility of dengue NS1-specific IgG antibodies as biomarkers of dengue exposure in CYD-TDV recipients and controls. We optimized and evaluated a quantitative anti-dengue NS1 IgG enzyme-linked immunosorbent assay (ELISA). Parameters assessed included: accuracy, dilutability/linearity, precision, limit of quantitation and specificity. The assay specificity was further evaluated using Japanese Encephalitis virus, West Nile virus, Yellow Fever virus or Zika virus positive sera samples collected following confirmed infection or vaccination. Receiver-operating-characteristics (ROC) curves as well as sensitivity and specificity for discriminating previous dengue exposure were assessed using 1250 reference samples. Overall, the anti-dengue NS1 IgG ELISA was able to discriminate previous dengue exposure from non-exposure before vaccination with CYD-TDV (ROC area under the curve > 0.9). Assessment of paired samples from 2511 vaccinated participants showed high overall agreement (93%) between pre-vaccination and post-vaccination dengue serostatus classification based on the anti-dengue NS1 IgG ELISA. However, misclassification of dengue serostatus was observed after vaccination likely due to a combination of asymptomatic dengue infections, assay variability and a modest effect of CYD-TDV on the anti-dengue NS1 IgG ELISA readout. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Penicillinase-based enzyme-linked immunosorbent assay for the detection of plant viruses.
Sudarshana, M R; Reddy, D V
1989-10-01
A penicillinase (PNC)-based, enzyme-linked immunosorbent assay (ELISA) was standardized to detect maize mosaic virus (MMV) in sorghum leaf extracts, peanut mottle virus (PMV) in pea leaf extracts, and tomato spotted wilt virus (TSWV) in peanut leaf extracts. Rabbit Fc-specific antibodies were conjugated with PNC by a single step glutaraldehyde bridge. Among several indicators tested, bromothymol blue (BTB) was found suitable for measuring PNC activity under simulated conditions. Two reagents, starch-iodine complex (SIC) and a mixed pH indicator, containing bromocresol purple and BTB (2:1) used earlier for the PNC-based ELISA, were compared with BTB for utilization in the PNC-based ELISA. SIC gave a slightly higher virus titre than BTB or the mixed pH indicator, but it often gave nonspecific reactions. Sodium or potassium salts of penicillin-G at 0.5-1.0 mg/ml and BTB at 0.2 mg/ml were found to be suitable as substrate-indicator mixture for PNC-based ELISA. The sensitivity of the PNC system was comparable to those of the alkaline phosphatase (ALP) and horseradish peroxidase (HRP) systems in detecting MMV, PMV, and TSWV. The PNC conjugate could be used at a greater dilution than those of the ALP and HRP conjugates and the BTB substrate mixture was stable for at least 3 weeks at 4 degrees C. Penicillin is readily available in developing countries, and at a substantially lower cost than p-nitrophenyl phosphate, the commonly used substrate for ALP in the plate ELISA. Thus the PNC-based ELISA provides a less expensive means for assaying plant viruses by ELISA.
Litster, Annette; Lin, Jui-Ming; Nichols, Jamieson; Weng, Hsin-Yi
2014-06-04
Antibody testing based on individual risk assessments is recommended to determine feline immunodeficiency virus (FIV) status, but ELISA and Western blot tests cannot distinguish between anti-FIV antibodies produced in response to natural infection and those produced in response to FIV vaccination. The aim of this cross-sectional study was to test the hypothesis that FIV-infected cats could be differentiated from FIV-vaccinated uninfected cats using lymphocyte subset results, specifically the CD4%:CD8(low)% T-lymphocyte ratio. Comparisons of the CD4%:CD8(low)% T-lymphocyte ratio were made among the following four groups: Group 1 - FIV-infected cats (n=61; FIV-antibody positive by ELISA and FIV PCR positive); Group 2 - FIV-uninfected cats (n=96; FIV-antibody negative by ELISA); Group 3 - FIV-vaccinated uninfected cats (n=31; FIV-antibody negative by ELISA before being vaccinated against FIV, after which they tested FIV ELISA positive); and Group 4 - FIV-uninfected but under chronic/active antigenic stimulation (n=16; FIV-antibody negative by ELISA; all had active clinical signs of either upper respiratory tract disease or gingival disease for ≥ 21 days). The median CD4%:CD8(low)% T-lymphocyte ratio was lower in Group 1 (1.39) than in each of the other three groups (Group 2 - 9.77, Group 3 - 9.72, Group 4 - 5.64; P<0.05). The CD4%:CD8(low)% T-lymphocyte ratio was also the most effective discriminator between FIV-infected cats and the other three groups, and areas under ROC curves ranged from 0.91 (compared with Group 4) to 0.96 (compared with Group 3). CD4%:CD8(low)% shows promise as an effective test to differentiate between FIV-infected cats and FIV-vaccinated uninfected cats. Copyright © 2014 Elsevier B.V. All rights reserved.
Assay optimisation and technology transfer for multi-site immuno-monitoring in vaccine trials
Harris, Stephanie A.; Satti, Iman; Bryan, Donna; Walker, K. Barry; Dockrell, Hazel M.; McShane, Helen; Ho, Mei Mei
2017-01-01
Cellular immunological assays are important tools for the monitoring of responses to T-cell-inducing vaccine candidates. As these bioassays are often technically complex and require considerable experience, careful technology transfer between laboratories is critical if high quality, reproducible data that allows comparison between sites, is to be generated. The aim of this study, funded by the European Union Framework Program 7-funded TRANSVAC project, was to optimise Standard Operating Procedures and the technology transfer process to maximise the reproducibility of three bioassays for interferon-gamma responses: enzyme-linked immunosorbent assay (ELISA), ex-vivo enzyme-linked immunospot and intracellular cytokine staining. We found that the initial variability in results generated across three different laboratories reduced following a combination of Standard Operating Procedure harmonisation and the undertaking of side-by-side training sessions in which assay operators performed each assay in the presence of an assay ‘lead’ operator. Mean inter-site coefficients of variance reduced following this training session when compared with the pre-training values, most notably for the ELISA assay. There was a trend for increased inter-site variability at lower response magnitudes for the ELISA and intracellular cytokine staining assays. In conclusion, we recommend that on-site operator training is an essential component of the assay technology transfer process and combined with harmonised Standard Operating Procedures will improve the quality, reproducibility and comparability of data produced across different laboratories. These data may be helpful in ongoing discussions of the potential risk/benefit of centralised immunological assay strategies for large clinical trials versus decentralised units. PMID:29020010
[Research of Human-mouse Chimeric Antibodies Against Ebola Virus Nucleoprotein].
Zhou, Rongping; Sun, Lina; Liu, Yang; Wu, Wei; Li, Chuan; Liang, Mifang; Qiu, Peihong
2016-01-01
The Ebola virus is highly infectious and can result in death in ≤ 90% of infected subjects. Detection of the Ebola virus and diagnosis of infection are extremely important for epidemic control. Presently, Chinese laboratories detect the nucleic acids of the Ebola virus by real-time reverse transcription-polymerase chain reaction (RT-PCR). However, such detection takes a relatively long time and necessitates skilled personnel and expensive equipment. Enzyme-linked immunosorbent assay (ELISA) of serum is simple, easy to operate, and can be used to ascertain if a patient is infected with the Ebola virus as well as the degree of infection. Hence, ELISA can be used in epidemiological investigations and is a strong complement to detection of nucleic acids. Cases of Ebola hemorrhagic fever have not been documented in China, so quality-control material for positive serology is needed. Construction and expression of human-mouse chimeric antibodies against the nucleoprotein of the Ebola virus was carried out. Genes encoding variable heavy (VH) and variable light (VL) chains were extracted and amplified from murine hybridoma cells. Genes encoding the VH and VL chains of monoclonal antibodies were amplified by RT-PCR. According to sequence analyses, a primer was designed to amplify functional sequences relative to VH and VL chain. The eukaryotic expression vector HL51-14 carrying some human antibody heavy chain- and light chain-constant regions was used. IgG antibodies were obtained by transient transfection of 293T cells. Subsequently, immunological detection and immunological identification were identified by ELISA, immunofluorescence assay, and western blotting. These results showed that we constructed and purified two human- mouse chimeric antibodies.
Zhang, Xiao; Xu, Chongxin; Zhang, Cunzheng; Liu, Yuan; Xie, Yajing; Liu, Xianjin
2014-04-01
ScFvs are composed of the variable regions of the heavy and light chains via a short linker that maintain the specific antigen binding abilities of antibodies. In this study, we constructed a naïve mouse phage displayed library to generate scFvs against Cry1Ab toxin. After affinity panning, positive phage-scFvs were isolated, sequenced and characterized by ELISA. The best binding ability scFv-G9 was expressed and purified. SDS-PAGE indicated that the relative molecular mass of scFv was estimated at 28 kDa. The purified scFv-G9 was used to develop a new DAS-ELISA for detecting Cry1Ab toxin, within minimum detection limit of 0.008 μg mL(-1), a working range 0.018-6.23 μg mL(-1), and the linear curve displayed an acceptable correlation coefficient of 0.98. The cross-reactivity showed that scFv-G9 had strongly binding ability to Cry1Ac toxin, but not to Cry1B, Cry1C and Cry1F toxin. The average recoveries of Cry1Ab toxin from spiked leaf and rice samples were in the range 92.1-94.8%, and 91.6-98.6%, respectively, with a coefficient of variation (C.V) less than 5.0%. These results showed promising applications of scfv-G9 for detecting Cry1Ab toxin with new DAS-ELISA. Copyright © 2014 Elsevier Ltd. All rights reserved.
New ELISA-based method for the detection of O-GlcNAc transferase activity in vitro.
Qi, Jieqiong; Wang, Ruihong; Zeng, Yazhen; Yu, Wengong; Gu, Yuchao
2017-08-09
O-GlcNAcylation is a dynamic, reversible, post-translational modification that regulates many cellular processes. O-GlcNAc transferase (OGT) is the sole enzyme transferring N-acetylglucosamine from uridine diphosphate (UDP)-GlcNAc to selected serine/threonine residues of cytoplasm and nucleus proteins. Aberrant of OGT activity is associated with several diseases, suggesting OGT as a novel therapeutic target. In this study, we created a new enzyme linked immunosorbent assays (ELISA)-based method for detection of OGT activity. First, casein kinase II (CKII), a well-known OGT substrate, was coated onto ELISA plate. Second, the GlcNAc transferred by OGT from UDP-GlcNAc to CKII was detected using an antibody to O-GlcNAc and then the horseradish peroxidase (HRP)-labeled secondary antibody. At last, 3,3',5,5'-tetramethylbenzidine (TMB), the substrate of HRP, was used to detect the O-GlcNAcylation level of CKII which reflected the activity of OGT. Based on a series of optimization experiments, the RL2 antibody was selected for O-GlcNAc detection and the concentrations of CKII, OGT, and UDP-GlcNAc were determined in this study. ST045849, a commercial OGT inhibitor, was used to verify the functionality of the system. Altogether, this study showed a method that could be applied to detect OGT activity and screen OGT inhibitors.
Burtonboy, S; Charlier, P; Hertoghs, J; Lobmann, M; Wiseman, A; Woods, S
1991-04-20
The performance of live, attenuated, homologous, canine parvovirus vaccines was studied in 140 puppies aged from four to 11 weeks. In the presence of maternally derived antibody the ability of the vaccines to elicit a serological response, as determined by the haemagglutination inhibition test and a standardised ELISA, was found to be dose (infectious titre) related. An experimental vaccine containing 10(7.0) TCID50 of virus induced seroconversion rates of 95, 89, 82 and 44 per cent in dogs with haemagglutination inhibition antibody titres of less than or equal to 8, 16, 32 and greater than 32, respectively. The standardised ELISA appeared to be better than the haemagglutination inhibition test with respect to variability and subjectivity, especially when titres were low.
Putalun, Waraporn
2011-03-01
Single chain fragment-variable (scFv) enhanced solasodine glycoside accumulation in Solanum khasianum hairy root cultures transformed by the ScFv solamargine (As)-scFv gene. The scFv protein was expressed at a high level in inclusion bodies of E. coli. After being renatured, the scFv protein was purified in a one-step manner by metal chelate affinity chromatography. The yield of refolded and purified scFv was 12.5 mg per 100 ml of cell culture. The characteristics of the As-scFv expressed in E. coli and transgenic hairy roots were similar to those of the parent monoclonal antibody (MAb). The expression of scFv protein provides a low cost and a high yield of functional scFv antibody against solamargine. The full linear range of the ELISA assay using scFv was extended from 1.5-10 µg/ml. The expressed anti-solamargine scFv protein could be useful for determination of total solasodine glycoside content in plant samples by ELISA. Solasodine glycoside levels in the transgenic hairy root were 2.3-fold higher than that in the wild-type hairy root based on the soluble protein level and binding activities. The As-scFv expressed in S. khasianum hairy roots enhanced solasodine glycosides accumulation and provide a novel medicinal plant breeding methodology that can produce a high yield of secondary metabolites.
Baritaki, S; Zafiropoulos, A; Georgopoulos, E; Souris, S; Krambovitis, E
2001-04-01
It has been demonstrated that IgG antibodies can be generated to self-antigen peptides as well as against viral antigens by an antigen-specific in vitro immunization system of resting human peripheral B-lymphocytes. Using a synthetic peptide from the consensus variable tandem-repeat region of the MUC3 mucin (TSSITTTGTTSHSTPSP) as the B cell epitope, we immunized blood donor B-lymphocytes in vitro and tested for MUC3-specific antibodies by ELISA. After the primary activation step all antibodies were IgM. At the end of the secondary immunization step we obtained 1.8% (21/1138) of the cultures with IgG-switched antibodies. In a competitive inhibition ELISA using the MUC1, MUC2, MUC3, MUC4 and PIP2 peptides, only one culture (F8.1) gave satisfactory specific inhibition. Using this antibody in fluorometric studies, it stained cells from two colon carcinoma cell lines predominantly in the cytoplasm, whereas those from a breast cancer cell line stained predominantly the cell surface. In a preliminary immunohistological evaluation with formalin-fixed sections, the antibody appeared to moderately stain colon sections, but not breast sections or lymph node. This method of in vitro immunization may be a useful tool in generating IgG antibodies specific to self-antigens and could find applications in tumour targeting and immunotherapy.
Mao, Shun; Lu, Ganhua; Yu, Kehan; ...
2010-01-01
We study the protein viability on Au nanoparticles during an electrospray and electrostatic-force-directed assembly process, through which Au nanoparticle-antibody conjugates are assembled onto the surface of carbon nanotubes (CNTs) to fabricate carbon nanotube field-effect transistor (CNTFET) biosensors. Enzyme-linked immunosorbent assay (ELISA) and field-effect transistor (FET) measurements have been used to investigate the antibody activity after the nanoparticle assembly. Upon the introduction of matching antigens, the colored reaction from the ELISA and the change in the electrical characteristic of the CNTFET device confirm that the antibody activity is preserved during the assembly process.
A microplate assay to measure classical and alternative complement activity.
Puissant-Lubrano, Bénédicte; Fortenfant, Françoise; Winterton, Peter; Blancher, Antoine
2017-05-01
We developed and validated a kinetic microplate hemolytic assay (HA) to quantify classical and alternative complement activity in a single dilution of human plasma or serum. The assay is based on monitoring hemolysis of sensitized sheep (or uncoated rabbit) red blood cells by means of a 96-well microplate reader. The activity of the calibrator was evaluated by reference to 200 healthy adults. The conversion of 50% hemolysis time into a percentage of activity was obtained using a calibration curve plotted daily. The linearity of the assay as well as interference (by hemolysis, bilrubinemia and lipemia) was assessed for classical pathway (CP). The within-day and the between-day precision was satisfactory regarding the performance of commercially available liposome immunoassay (LIA) and ELISA. Patients with hereditary or acquired complement deficiencies were detected (activity was measured <30%). We also provided a reference range obtained from 200 blood donors. The agreement of CP evaluated on samples from 48 patients was 94% with LIA and 87.5% with ELISA. The sensitivity of our assay was better than that of LIA, and the cost was lower than either LIA or ELISA. In addition, this assay was less time consuming than previously reported HAs. This assay allows the simultaneous measurement of 36 samples in duplicate per run of a 96-well plate. The use of a daily calibration curve allows standardization of the method and leads to good reproducibility. The same technique was also adapted for the quantification of alternative pathway (AP) activity.
Koga, Hiroshi; Teye, Kwesi; Ishii, Norito; Ohata, Chika; Nakama, Takekuni
2018-01-01
Bullous pemphigoid (BP) presenting with erythema plaques and tense blisters is the most frequent autoimmune bullous disease. Immunologically, BP is characterized by the presence of circulating anti-epidermal basement membrane zone (BMZ) antibodies. The autoantigens in BMZs targeted by patient's antibodies are mainly BP180 (type XVII collagen) and BP230. Previous reports have indicated that IgG to the immunodominant region of BP180 in BP, 16th non-collagenous domain (NC16A), and anti-BP180NC16A IgE are related to disease activity. In the cytokine profile, serum levels of IL-6, TNF-α, IL-15, and CCL18 were associated with the severity or activity of the disease. Blood eosinophilia is seen frequently, especially in severe cases. These biomarkers are helpful to evaluate efficacy of treatment and disease severity. Due to the high frequency of disease relapse, prediction of relapse at initiation of treatment (baseline) must be beneficial for clinicians. Therefore, we evaluated biomarkers anti-BP180 IgG (BP180 ELISA), anti-BP230 IgG (BP230 ELISA), peripheral eosinophils, and serum IgE at baseline between BP patients with (n = 16) and without (n = 31) relapse. We found significantly higher index values of BP180 ELISA in the relapse group, whereas no significant difference was found in BP230 ELISA, peripheral eosinophils, and serum IgE. This study indicated that a high index value of BP180 ELISA (cutoff value, 53.09 U/mL; sensitivity, 81.3%; specificity, 48.4%) at baseline may predict relapse in patients with BP. This may help clinicians treating BP patients in decision-making regarding duration and intensity of treatment. PMID:29868591
CSF biomarker variability in the Alzheimer’s Association quality control program
Mattsson, Niklas; Andreasson, Ulf; Persson, Staffan; Carrillo, Maria C.; Collins, Steven; Chalbot, Sonia; Cutler, Neal; Dufour-Rainfray, Diane; Fagan, Anne M.; Heegaard, Niels H. H.; Hsiung, Ging-Yuek Robin; Hyman, Bradley; Iqbal, Khalid; Lachno, D. Richard; Lleó, Alberto; Lewczuk, Piotr; Molinuevo, José L.; Parchi, Piero; Regeniter, Axel; Rissman, Robert; Rosenmann, Hanna; Sancesario, Giuseppe; Schröder, Johannes; Shaw, Leslie M.; Teunissen, Charlotte E.; Trojanowski, John Q.; Vanderstichele, Hugo; Vandijck, Manu; Verbeek, Marcel M.; Zetterberg, Henrik; Blennow, Kaj; Käser, Stephan A.
2013-01-01
Background The cerebrospinal fluid (CSF) biomarkers amyloid beta 1–42, total tau, and phosphorylated tau are used increasingly for Alzheimer’s disease (AD) research and patient management. However, there are large variations in biomarker measurements among and within laboratories. Methods Data from the first nine rounds of the Alzheimer’s Association quality control program was used to define the extent and sources of analytical variability. In each round, three CSF samples prepared at the Clinical Neurochemistry Laboratory (Mölndal, Sweden) were analyzed by single-analyte enzyme-linked immunosorbent assay (ELISA), a multiplexing xMAP assay, or an immunoassay with electrochemoluminescence detection. Results A total of 84 laboratories participated. Coefficients of variation (CVs) between laboratories were around 20% to 30%; within-run CVs, less than 5% to 10%; and longitudinal within-laboratory CVs, 5% to 19%. Interestingly, longitudinal within-laboratory CV differed between biomarkers at individual laboratories, suggesting that a component of it was assay dependent. Variability between kit lots and between laboratories both had a major influence on amyloid beta 1–42 measurements, but for total tau and phosphorylated tau, between-kit lot effects were much less than between-laboratory effects. Despite the measurement variability, the between-laboratory consistency in classification of samples (using prehoc-derived cutoffs for AD) was high (>90% in 15 of 18 samples for ELISA and in 12 of 18 samples for xMAP). Conclusions The overall variability remains too high to allow assignment of universal biomarker cutoff values for a specific intended use. Each laboratory must ensure longitudinal stability in its measurements and use internally qualified cutoff levels. Further standardization of laboratory procedures and improvement of kit performance will likely increase the usefulness of CSF AD biomarkers for researchers and clinicians. PMID:23622690
Sakamoto, Seiichi; Pongkitwitoon, Benyakan; Nakamura, Seiko; Sasaki-Tabata, Kaori; Tanizaki, Yusuke; Maenaka, Katsumi; Tanaka, Hiroyuki; Morimoto, Satoshi
2011-07-01
A single-chain variable fragment antibody against herbicide, 2,4-dichlorophenoxyacetic acid (2,4-D-scFv) has been successfully expressed in the hemolymph of silkworm larvae using a rapid Bombyx mori nucleopolyhedrovirus (BmNPV) bacmid DNA system. Variable heavy- and light-chain domains were cloned directly from the cDNA of the hybridoma cell line 2C4 and assembled together with flexible peptide linker (Gly(4)Ser)(3) between two domains. The yield of functional 2,4-D-scFv after purification was 640 μg per 30 ml of hemolymph, which is equivalent to 21.3 mg per liter of hemolymph. The characterization of 2,4-D-scFv using an indirect competitive enzyme-linked immunosorbent assay (icELISA) revealed that it has wide cross-reactivities against 2,4,5-trichlorophenoxyacetic acid (65.5%), 2,4-dichlorophenol (47.9%), and 2,4-dichlorobenzoic acid (26.0%), making it possible to apply 2,4-D-scFv to icELISA for detecting/determining 2,4-D and its metabolites. Judging from its cost and time requirements and its ease of handling, this BmNPV bacmid DNA expression system is more useful for expressing functional scFv than bacterial systems, which frequently require costly and time-consuming refolding.
Zwerink, M; Zomer, T P; van Kooten, B; Blaauw, G; van Bemmel, T; van Hees, B C; Vermeeren, Y M; Landman, G W
2018-03-01
A two-step testing strategy is recommended in serological testing for Lyme borreliosis; positive and indeterminate enzyme-linked immunosorbent assay (ELISA) results are confirmed with immunoblots. Several ELISAs quantify the concentration of antibodies tested, however, no recommendation exists for an upper cut-off value at which an IgG ELISA is sufficient and the immunoblot can be omitted. The study objective was to determine at which IgG antibody level an immunoblot does not have any additional predictive value compared to ELISA results. Data of adult patients who visited a tertiary Lyme centre between 2008 and 2014 were analysed. Both an ELISA (Enzygnost Lyme link VlsE IgG) and immunoblot (recomLine blot Borrelia) were performed. Clinical data were extracted from the patient's digital medical record. Positive predictive values (PPVs) for either previous or active infection with Borrelia burgdorferi s.l. were calculated for different cut-off ELISA IgG antibody levels where the immunoblot was regarded as reference test. In total, 1454 patients were included. According to the two-step test strategy, 486 (33%), 69 (5%) and 899 (62%) patients had positive, indeterminate and negative Borrelia IgG serology, respectively. At IgG levels of 500 IU/ml and higher, all immunoblots were positive, resulting in a 100% PPV (95% CI: 97.0-100). At IgG levels of 200 IU/ml and higher, the PPV was 99.3% (95% CI: 97.4-99.8). In conclusion, at IgG levels of 200 IU/ml and higher, an ELISA was sufficient to detect antibodies to Borrelia burgdorferi s.l. At those IgG levels, a confirmatory immunoblot may be omitted in patients referred to a tertiary Lyme centre. Before these results can be implemented in routine diagnosis of Lyme borreliosis, confirmation of the results is necessary in other patient populations and using other quantitative ELISAs and immunoblots. Copyright © 2017 Elsevier GmbH. All rights reserved.
Carvalho, Fernando R; Silva, Deise A O; Cunha-Júnior, Jair P; Souza, Maria A; Oliveira, Taísa C; Béla, Samantha R; Faria, Gabriele G; Lopes, Carolina S; Mineo, José R
2008-08-01
The present study aimed to evaluate the performance of three monoclonal antibodies (MAbs) in reverse enzyme-linked immunosorbent assays (ELISAs) for detecting immunoglobulin G (IgG), IgM, and IgA antibodies against Toxoplasma gondii in 175 serum samples from patients at different stages of T. gondii infection, as defined by both serological and clinical criteria, as follows: recent (n = 45), transient (n = 40), and chronic (n = 55) infection as well as seronegative subjects (n = 35). The results were compared with those obtained by indirect ELISA using soluble Toxoplasma total antigen (STAg). Our data demonstrated that MAb A3A4 recognizes a conformational epitope in SAG1-related-sequence (SRS) antigens, while A4D12 and 1B8 recognize linear epitopes defined as SAG2A surface antigen and p97 cytoplasmatic antigen, respectively. Reverse ELISA for IgG with A3A4 or A4D12 MAbs was highly correlated with indirect ELISA for anti-STAg IgG, whereas only A4D12 reverse ELISA showed high correlation with indirect ELISA for IgM and IgA isotypes. To our knowledge, this is the first report analyzing the performance of a reverse ELISA for simultaneous detection of IgG, IgM, and IgA isotypes active toward native SAG2A, SRS, and p97 molecules from STAg, using a panel of human sera from patients with recent and chronic toxoplasmosis. Thus, reverse ELISA based on the capture of native SAG2A and SRS antigens of STAg by MAbs could be an additional approach for strengthening the helpfulness of serological tests assessing the stage of infection, particularly in combination with highly sensitive and specific assays that are frequently used nowadays for diagnosis of toxoplasmosis during pregnancy or congenital infection in newborns.
Badaut, Cyril; Bertin, Gwladys; Rustico, Tatiana; Fievet, Nadine; Massougbodji, Achille; Gaye, Alioune; Deloron, Philippe
2010-01-01
Background Placental malaria is a disease linked to the sequestration of Plasmodium falciparum infected red blood cells (IRBC) in the placenta, leading to reduced materno-fetal exchanges and to local inflammation. One of the virulence factors of P. falciparum involved in cytoadherence to chondroitin sulfate A, its placental receptor, is the adhesive protein VAR2CSA. Its localisation on the surface of IRBC makes it accessible to the immune system. VAR2CSA contains six DBL domains. The DBL6ε domain is the most variable. High variability constitutes a means for the parasite to evade the host immune response. The DBL6ε domain could constitute a very attractive basis for a vaccine candidate but its reported variability necessitates, for antigenic characterisations, identifying and classifying commonalities across isolates. Methodology/Principal Findings Local alignment analysis of the DBL6ε domain had revealed that it is not as variable as previously described. Variability is concentrated in seven regions present on the surface of the DBL6ε domain. The main goal of our work is to classify and group variable sequences that will simplify further research to determine dominant epitopes. Firstly, variable sequences were grouped following their average percent pairwise identity (APPI). Groups comprising many variable sequences sharing low variability were found. Secondly, ELISA experiments following the IgG recognition of a recombinant DBL6ε domain, and of peptides mimicking its seven variable blocks, allowed to determine an APPI cut-off and to isolate groups represented by a single consensus sequence. Conclusions/Significance A new sequence approach is used to compare variable regions in sequences that have extensive segmental gene relationship. Using this approach, the VAR2CSA DBL6 domain is composed of 7 variable blocks with limited polymorphism. Each variable block is composed of a limited number of consensus types. Based on peptide based ELISA, variable blocks with 85% or greater sequence identity are expected to be recognized equally well by antibody and can be considered the same consensus type. Therefore, the analysis of the antibody response against the classified small number of sequences should be helpful to determine epitopes. PMID:20585655
Miura, Kazutoyo; Zhou, Hong; Moretz, Samuel E.; Diouf, Ababacar; Thera, Mahamadou A; Dolo, Amagana; Doumbo, Ogobara; Malkin, Elissa; Diemert, David; Miller, Louis H.; Mullen, Gregory E.D.; Long, Carole A.
2009-01-01
Vaccines represent a significant potential means of decreasing global morbidity and mortality due to malaria. Clinical trials in the U.S. with Plasmodium falciparum Apical Membrane Antigen 1 (AMA1) showed that the vaccine induced biologically active antibodies judged by an in vitro parasite Growth Inhibition Assay (GIA). However, the same vaccine in Malian adults did not increase biological activity although it elevated ELISA titers. As GIA has been used to evaluate the biological activity of antibodies induced by blood-stage malarial vaccine candidates, we explored this discrepancy in this study. We affinity purified AMA1-specific antibodies from both US vaccinees and from non-vaccinated individuals living in a malaria-endemic area of Mali, and performed ELISA and GIA. Both AMA1-specifc antibodies induced by vaccination (US) and by natural infection (Mali) have comparable biological activity in GIA when the ELISA titer is normalized. However, a fraction of Malians’ IgG which did not bind to AMA1 protein (Mali-non-AMA1 IgG) reduced the biological activity of the AMA1 antibodies from US vaccinees; in contrast, US-non-AMA1 IgGs did not show a reduction of the biological activity. Further investigation revealed that the reduction was due to malaria-specific IgGs in the Mali-non-AMA1 IgGs. The fact that both US- and Mali-AMA1-specific antibodies showed comparable biological activity supports further development of AMA1-based vaccines. However, the reduction of biological activity of AMA1-specific antibody by other malaria-specific IgGs likely explains the limited effect on growth-inhibitory activity of antibodies induced by AMA1 vaccination in Malian adults and may complicate efforts to develop a blood-stage malaria vaccine. PMID:19050299
Toxoplasmosis among pregnant women in Qualyobia Governorate, Egypt.
El-Gozamy, Bothina R; Mohamed, Sabry Abdel-fattah; Mansour, Hadil Ahmad M
2009-08-01
This study was conducted between August 2007 and October 2008 to identify the sero-prevalence of Toxoplasma gondii among pregnant women of different ages and stages of gestation. Latex agglutination test was used as screening test. ELISA-IgG & IgM tests measured for the Toxo-Latex positive cases to identify toxoplasmosis clinical status. The results indicated that the prevalence of T. gondii among pregnant women was relatively high in the rural (57.6%) than urban (46.5%) areas. The positivity was correlated, in general, with age as it was higher in the older age groups. No specific clinical pictures were noticed in different patients with variable proportions, as well as a less marked correlation between Toxo-latex positive cases and having toxoplasmic congenital babies. But, neither correlation was detected between the history of congenital toxoplasmosis, or contact with cats and the Toxo-latex out-come results. An acute newly infected pregnant women during their first trimester of pregnancy that represents the rate of incidence of T. gondii in which ELISA-IgM positive and ELISA-IgG negative, was 23 cases (27.05%) and v.v. was 20 (23.54). The interpretation of IgM and IgG was given.
Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay*
DALBY, TINE; SØRENSEN, CHARLOTTE; PETERSEN, JESPER WESTPHAL; KROGFELT, KAREN ANGELIKI
2010-01-01
Dalby T, Sørensen C, Petersen JW, Krogfelt KA. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay. APMIS 2010; 118: 968–72. Two types of serological assays are commonly used for the assessment of pertussis vaccine-induced antibodies; the Chinese hamster ovary cell (CHO cell) assay and the immunoglobulin G (IgG) anti pertussis toxin (PT) enzyme-linked immunosorbent assay (IgG anti-PT ELISA). Recently, both the techniques have been modified to improve performance with sera with interfering activity (CHO cell assay) or with heat-treated sera (IgG anti-PT ELISA). These two improved techniques were compared by the analysis of 100 individual serum samples from a previous clinical trial and 213 sera from a longitudinal serum collection from 20 Danish adults recently vaccinated with the Danish acellular pertussis vaccine. The comparison showed a significant linear correlation between the results of the two assays with a p-value of <0.0001 for the 100 individual samples. We, therefore, conclude that the improved IgG anti-PT ELISA can be used as a replacement for the often troublesome and time-consuming CHO cell assay for the measurement of vaccine-induced human antibodies to PT. PMID:21091778
Fablet, C; Rose, N; Bernard, C; Messager, I; Piel, Y; Grasland, B
2017-11-01
This study was designed to assess the diagnostic characteristics of two PCV2 ELISAs without a gold standard. Four hundred and sixty-five serum samples from finishing pigs (25 herds) not vaccinated against PCV2 were used. Samples were tested by two ELISAs: an in-house ELISA (I-ELISA) and the commercial SERELISA ® PCV2 Ab Mono Blocking kit (S-ELISA). A ROC curve was used to assess the S-ELISA's optimal threshold by taking the I-ELISA as a reference and using the cut-off previously determined by comparison to an cccmonolayer assay (IPMA). This led to an S-ELISA result ≥170 being considered as positive. The sensitivity (Se) and specificity (Sp) of each ELISA were then estimated without a gold standard using a Bayesian approach. The mean Se and Sp values of the I-ELISA were slightly higher than those of the S-ELISA (mean Se I-ELISA=0.90 vs. mean Se S-ELISA=0.86; mean Sp I-ELISA=0.92 vs. mean Sp S-ELISA=0.85). However, the 95% credibility intervals (CI95%) overlapped (Se I-ELISA CI95%=0.85-0.95 vs. Se S-ELISA CI95%=0.82-0.90; Sp I-ELISA CI95%=0.82-0.98 vs. Sp S-ELISA CI95%=0.75-0.94). Both ELISAs appeared to be valuable tools for detecting PCV2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Minghua; Wang, Zhaoyue; Yu, Ziqiang; Bai, Xia; Su, Jian; Cao, Lijuan; Zhang, Wei; Ruan, Changgeng
2011-06-01
Congenital factor VII (FVII) deficiency is a rare autosomal recessive bleeding disorder. Its clinical manifestation and mutational spectrum are highly variable. The purpose of this study was to identify and characterize the mutation causing the FVII deficiency in a Chinese patient and his family. The FVII gene was analyzed by genomic DNA sequencing, and the FVII levels in patient's plasma were measured with an enzyme-linked immunoabsorbent assay (ELISA) and one-stage prothrombin time based method. In addition, the FVII-Phe190 mutant identified in the pedigree was expressed in the HEK293 cells, and the subcellular localization experiments in the Chinese hamster ovary (CHO) cells were performed. The patient had a prolonged prothrombin time and low levels of both FVII antigen and activity, and two heterozygous mutations were identified in F7 gene (NG-009262.1): a g.15975 G>A in the splice receptor site of intron 6 and a novel g.16750 C>T in exon 8 resulting in Ser190 to Phe190 replacement. In expression experiments, the reduced antigen and activity levels of FVII-Phe190 in the culture medium were found, whereas an ELISA and Western blotting analysis of FVII revealed that mutant FVII-Phe190 was synthesized in the cells as the wild-type FVII-Ser190. And FVII-Phe190 was found in endoplasmic reticulum and Golgi apparatus. Compound heterozygous mutations in F7 gene should be responsible for the FVII deficiency in this patient. The FVII-Phe190 can normally be synthesized and transported from endoplasmic reticulum to Golgi apparatus, but degraded or inefficiently secreted.
Takeuchi-Storm, Nao; Denwood, Matthew; Hansen, Tina Vicky Alstrup; Halasa, Tariq; Rattenborg, Erik; Boes, Jaap; Enemark, Heidi Larsen; Thamsborg, Stig Milan
2017-11-09
The prevalence of bovine fasciolosis in Denmark is increasing but appropriate guidelines for control are currently lacking. In order to help develop a control strategy for liver fluke, a risk factor study of farm management factors was conducted and the utility of bulk tank milk (BTM ELISA) as a tool for diagnosis in Danish dairy cattle farms was assessed. This case-control study aimed to identify farm-level risk factors for fasciolosis in Danish dairy farms (> 50 animals slaughtered in 2013) using two diagnostic methods: recordings of liver condemnation at slaughter, and farm-level Fasciola hepatica antibody levels in BTM. A case farm was defined as having a minimum of 3 incidents of liver condemnation due to liver fluke at slaughter (in any age group) during 2013, and control farms were located within 10 km of at least one case farm and had no history of liver condemnation due to liver fluke during 2011-2013. The selected farmers were interviewed over telephone about grazing and control practices, and BTM from these farms was collected and analysed by ELISA in 2014. The final complete dataset consisting of 131 case and 63 control farms was analysed using logistic regression. Heifers grazing on wet pastures, dry cows grazing on wet pastures, herd size, breed and concurrent beef cattle production were identified as risk factors associated with being classified as a case farm. With the categorised BTM ELISA result as the response variable, heifers grazing on wet pastures, dry cows grazing on wet pastures, and purchase of cows were identified as risk factors. Within the case and control groups, 74.8 and 12.7% of farms were positive for fasciolosis on BTM ELISA, respectively. The differences are likely to be related to the detection limit of the farm-level prevalence by the BTM ELISA test, time span between slaughter data and BTM, and the relatively low sensitivity of liver inspection at slaughter. Control of bovine fasciolosis in Denmark should target heifers and dry cows through grazing management and appropriate anthelmintic treatment, and BTM ELISA can be a useful diagnostic tool for fasciolosis in Danish dairy farms.
Pose, A G; Rodríguez, E S; Méndez, A C; Gómez, J N; Redondo, A V; Rodríguez, E R; Ramos, E M G; Gutiérrez, A Á; Moltó, M P R; Roche, D G; Ugalde, Y S; López, A M
2015-01-01
In this study we demonstrated that the vaccine candidate against avian influenza virus H5N1 based on the hemagglutinin H5 (HA) fused to the chicken CD154 (HACD) can also be used for differentiating infected from vaccinated animals (DIVA). As the strategy of DIVA requires at least two proteins, we obtained a variant of the nucleoprotein (NP49-375) in E. coli. After its purification by IMAC, the competence of the proteins NP49-375 and HACD as coating antigens in indirect ELISA assays were tested by using the sera of chickens immunized with the proteins HA and HACD and the reference sera from several avian influenza subtypes. Together with these sera, the sera from different species of birds and the sera of chickens infected with other avian viral diseases were analyzed by competition ELISA assays coated with the proteins NP49-375 and HACD. The results showed that the segment CD154 in the chimeric protein HACD did not interfere with the recognition of the molecule HA by its specific antibodies. Also, we observed variable detection levels when the reference sera were analyzed in the ELISA plates coated with the protein NP49-375. Moreover, only the antibodies of the reference serum subtype H5 were detected in the ELISA plates coated with the protein HACD. The competition ELISA assays showed percentages of inhibition of 88-91% for the positives sera and less than 20% for the negative sera. We fixed the cut-off value of these assays at 25%. No antibody detection was observed in the sera from different species of birds or the sera of chickens infected with other avian viral diseases. This study supported the fact that the ELISA assays using the proteins NP49-375 and HACD could be valuable tools for avian influenza surveillance and as a strategy of DIVA for counteracting the highly pathogenic avian influenza virus H5N1 outbreaks.
Srila, Witsanu; Yuttavanichakul, Watcharin; Teamtisong, Kamonluck; Teaumroong, Neung; Boonkerd, Nantakorn; Tittabutr, Panlada
2017-01-01
A simple and reliable method for the detection of specific nitrogen-fixing bacteria in both free-living and bacteroid forms is essential for the development and application of biofertilizer. Traditionally, a polyclonal antibody generated from an immunized rabbit was used for detection. However, the disadvantages of using a polyclonal antibody include limited supply and cross-reactivity to related bacterial strains. This is the first report on the application of phage display technology for the generation of a rabbit recombinant monoclonal antibody for specific detection and monitoring of nitrogen-fixing bacteria in both free-living form and in plant nodules. Bradyrhizobium sp. DOA9, a broad host range soil bacteria, originally isolated from the root nodules of Aeschynomene americana in Thailand was used as a model in this study. A recombinant single-chain fragment variable (scFv) antibody library was constructed from the spleen of a rabbit immunized with DOA9. After three rounds of biopanning, one specific phage-displayed scFv antibody, designated bDOA9rb8, was identified. Specific binding of this antibody was confirmed by phage enzyme-linked immunosorbent assay (phage ELISA). The phage antibody could bind specifically to DOA9 in both free-living cells (pure culture) and bacteroids inside plant nodules. In addition to phage ELISA, specific and robust immunofluorescence staining of both free-living and bacteroid forms could also be observed by confocal-immunofluorescence imaging, without cross-reactivity with other tested bradyrhizobial strains. Moreover, specific binding of free scFv to DOA9 was also demonstrated by ELISA. This recombinant antibody can also be used for the study of the molecular mechanism of plant–microbe interactions in the future. PMID:28654662
Vu, Nguyen Xuan; Pruksametanan, Natcha; Srila, Witsanu; Yuttavanichakul, Watcharin; Teamtisong, Kamonluck; Teaumroong, Neung; Boonkerd, Nantakorn; Tittabutr, Panlada; Yamabhai, Montarop
2017-01-01
A simple and reliable method for the detection of specific nitrogen-fixing bacteria in both free-living and bacteroid forms is essential for the development and application of biofertilizer. Traditionally, a polyclonal antibody generated from an immunized rabbit was used for detection. However, the disadvantages of using a polyclonal antibody include limited supply and cross-reactivity to related bacterial strains. This is the first report on the application of phage display technology for the generation of a rabbit recombinant monoclonal antibody for specific detection and monitoring of nitrogen-fixing bacteria in both free-living form and in plant nodules. Bradyrhizobium sp. DOA9, a broad host range soil bacteria, originally isolated from the root nodules of Aeschynomene americana in Thailand was used as a model in this study. A recombinant single-chain fragment variable (scFv) antibody library was constructed from the spleen of a rabbit immunized with DOA9. After three rounds of biopanning, one specific phage-displayed scFv antibody, designated bDOA9rb8, was identified. Specific binding of this antibody was confirmed by phage enzyme-linked immunosorbent assay (phage ELISA). The phage antibody could bind specifically to DOA9 in both free-living cells (pure culture) and bacteroids inside plant nodules. In addition to phage ELISA, specific and robust immunofluorescence staining of both free-living and bacteroid forms could also be observed by confocal-immunofluorescence imaging, without cross-reactivity with other tested bradyrhizobial strains. Moreover, specific binding of free scFv to DOA9 was also demonstrated by ELISA. This recombinant antibody can also be used for the study of the molecular mechanism of plant-microbe interactions in the future.
Eberle, Kirsten C.; Venn-Watson, Stephanie K.; Jensen, Eric D.; LaBresh, Joanna; Sullivan, Yvonne; Kakach, Laura
2018-01-01
Monitoring the immune status of cetaceans is important for a variety of health conditions. Assays to quantify cytokines, especially pro-inflammatory cytokines, could be employed, in addition to currently available diagnostic assays, to screen for alterations in the health status of an animal. Though a number of immunological assays are readily available for humans and mice, specific assays for many veterinary species, including cetaceans such as bottlenose dolphins (Tursiops truncatus), are more limited. Herein, we describe the development of IFN-gamma (IFN-γ) and TNF-alpha (TNF-α) enzyme-linked immunosorbent assays (ELISAs) specific to bottlenose dolphins. Utilizing these assays, we monitored the immune status of bottlenose dolphins from a managed population over a period of eleven months. The ELISA assays developed for bottlenose dolphins were used to measure IFN-γ and TNF-α in serum or in culture supernatants from peripheral blood mononuclear cells (PBMCs) stimulated with varying concentrations of mitogens concanavalin A (ConA) or phytohemagglutinin (PHA). Induction of TNF-α in PBMC cultures was consistently highest with 1 μg/mL ConA, while 1 μg/mL PHA induced the highest secretion of IFN-γ. Serum levels of TNF-α and IFN-γ remained relatively constant for each animal over the time period examined. CBC and plasma chemistry variables measured concurrently in the bottlenose dolphins were then examined as independent predictors of cytokine levels. We found these clinical variables were more likely to predict linear changes in serum IFN-γ and TNF-α levels compared to concentrations of these cytokines in mitogen-stimulated PBMC culture supernatants. Cytokine assays developed will be of substantial benefit in monitoring bottlenose dolphin health as an adjunct to currently available diagnostic tests. PMID:29304133
de Re, Valli; Simula, Maria Paola; Pavan, Alessandro; Garziera, Marica; Marin, Dolores; Dolcetti, Riccardo; de Vita, Salvatore; Sansonno, Domenico; Geremia, Silvano; Toffoli, Giuseppe
2009-09-01
Autoimmune type-II cryoglobulinemia (II-MC) is sustained by hepatitis C virus (HCV) infection and B-cell (oligo)clones. This is the reason why the disease may be considered an "indolent B-cell lymphoma (NHL)." B clones show a restricted use of immunoglobulin variable genes (BCR), in particular in the use of the variable kappa (VK)3-20/15 light chain, and show a homology between their BCR functional regions and those of autoimmune rheumatoid factors. We underlined the BCR unique repertoire with frequent rheumatoid factor activity also observed in other autoimmune disorders associated with NHL. The immunoglobulin idiotype is a clonal B-cell marker and an ideal target for immunotherapy. Five monoclonal antibodies were produced in our laboratory toward the VK3-20 of a subject with HCV infection and a II-MC-associated NHL. Epitope determination was performed using the epitope excision approach. Monoclonal antibody reactivity was tested in vitro in ELISA, Western blot, and cytofluorimetry. Data confirmed that a panel of antibodies, reactive against shared idiotypes, can be produced from patients with HCV-associated B-cell lymphoproliferative diseases, thus obviating the need to produce an anti-idiotype antibody for each patient.
Cakir-Koc, Rabia
2016-08-01
Chicken egg yolk antibody, also known as immunoglobulin Y (IgY), is the predominant class of serum immunoglobulin in birds. IgY has many advantages over mammalian antibodies, such as enhanced immunogenicity conserved mammalian proteins exhibited in birds due to their phylogenetic distance, non-invasive rapid, and economical collection system. However, there are limited studies about IgY production against Toxoplasma, which is a worldwide veterinary and public health problem. In this study, the production of specific IgY antibodies against the surface antigen 1 (SAG1) protein of Toxoplasma gondii and the determination of antibody activity via the enzyme-linked immunosorbent assay (ELISA) method were conducted. According to ELISA, Western blot, and NanoDrop results, specific and higher amounts of IgY antibody against SAG1 were obtained with this study. Considering the advantages of IgY and importance of SAG1 for the diagnosis of toxoplasmosis, it is expected that anti-SAG1 IgY will play an increasing role and gain commercial value in research, diagnostics, and immunotherapy against toxoplasmosis in the future.
Sattler, Tatjana; Wodak, Eveline; Revilla-Fernández, Sandra; Schmoll, Friedrich
2014-12-18
In recent years, several new ELISAs for the detection of antibodies against the porcine reproductive and respiratory disease virus (PRRSV) in pig serum have been developed. To interpret the results, specificity and sensitivity data as well as agreement to a reference ELISA must be available. In this study, three commercial ELISAs (INgezim PRRS 2.0 - ELISA II, Priocheck® PRRSV Ab porcine - ELISA III and CIVTEST suis PRRS E/S PLUS - ELISA IV, detecting PRRSV type 1 antibodies) were compared to a standard ELISA (IDEXX PRRS X3 Ab Test - ELISA I). The serum of three pigs vaccinated with an attenuated PRRSV live vaccine (genotype 2) was tested prior to and several times after the vaccination. Furthermore, serum samples of 245 pigs of PRRSV positive herds, 309 pigs of monitored PRRSV negative herds, 256 fatteners of assumed PRRSV negative herds with unknown herd history and 92 wild boars were tested with all four ELISAs. ELISAs II and III were able to detect seroconversion of vaccinated pigs with a similar reliability. According to kappa coefficient, the results showed an almost perfect agreement between ELISA I as reference and ELISA II and III (kappa > 0.8), and substantial agreement between ELISA I and ELISA IV (kappa = 0.71). Sensitivity of ELISA II, III and IV was 96.0%, 100% and 91.5%, respectively. The specificity of the ELISAs determined in samples of monitored PRRSV negative herds was 99.0%, 95.1% and 96.4%, respectively. In assumed negative farms that were not continually monitored, more positive samples were found with ELISA II to IV. The reference ELISA I had a specificity of 100% in this study. All tested ELISAs were able to detect a PRRSV positive herd. The specificity and sensitivity of the tested commercial ELISAs, however, differed. ELISA II had the highest specificity and ELISA III had the highest sensitivity in comparison to the reference ELISA. ELISA IV had a lower sensitivity and specificity than the other ELISAs.
Ghasemi, Faezeh; Ghayour-Mobarhan, Majid; Pasdar, Alireza; Pourianfar, Hamid; Reza Aghasadeghi, Mohammad; Gouklani, Hamed; Meshkat, Zahra
2016-01-01
Background The E2 glycoprotein is an important encoded hepatitis C virus (HCV) protein that contains three different variable regions. Objectives The aim of the present study was to construct an HCV 1a/JFH1 chimeric virus by replacing the intergenotypic variable region (igVR) fragment of the highly variable region of the E2 gene of the Japanese Fulminant hepatitis genotype 2a JFH1 virus with a similar region of HCV genotype 1a. This chimera was produced as a model virus with the ability to be cultured. We analyzed the adapted virus and the variations of nucleic acids within it. Methods Specific primers were designed for the igVR of HCV genotype 1a followed by the overlap-PCR method for the synthesis of the desired DNA fragment. The amplified igVR-1a chimera gene and pFL-J6/JFH were digested by KpnI and BsiWI restriction enzymes, and the fragment was ligated into pFL-J6/JFH. The recombinant vector was transformed into Escherichia coli JM109 strain competent cells. All clones were confirmed by colony PCR using specific primers, and the confirmed recombinant vector was sequenced. The recombinant vector was targeted for RNA synthesis by T7 RNA polymerase enzyme. RNA transfection was performed in the Huh7.5 cell line. Virus production in several passages and the evaluated viral load were studied using quantitative real-time PCR and ELISA methods. After 30 passages, the RNA virus was extracted and cloned in PCDNA3.1 vector, and was then sequenced Results Quantitative real-time PCR results showed 11,292,514 copies/mL of chimeric virus production in cell culture. The virus production was confirmed using ELISA, which showed a virus core production of 808.2 pg/mL. The results of cloning and sequencing showed that some of the nucleic acids in the chimera virus were changed, affecting the viral behavior in the cell culture. Conclusions Real-time PCR and ELISA showed high levels of production of 1a/JFH1 chimeric HCV in the Huh7.5 cell culture. The constructed virus can be used for future studies, including the development of new HCV drugs and vaccines. PMID:27882063
Orjuela-Sánchez, Pamela; Duggan, Erika; Nolan, John; Frangos, John A; Carvalho, Leonardo Jm
2012-11-05
Plasmodium berghei rodent malaria is a well-known model for the investigation of anti-malarial drug efficacy in vivo. However, the availability of drug in vitro assays in P. berghei is reduced when compared with the spectrum of techniques existing for Plasmodium falciparum. New alternatives to the current manual or automated methods described for P. berghei are attractive. The present study reports a new ELISA drug in vitro assay for P. berghei using two monoclonal antibodies against the parasite lactate dehydrogenase (pLDH). This procedure includes a short-in vitro culture, the purification of schizonts and the further generation of synchronized mice infections. Early stages of the parasite are then incubated against different concentrations of anti-malarial drugs using micro-plates. The novelty of this procedure in P. berghei relies on the quantification of the drug activity derived from the amount of pLDH estimated by an ELISA assay using two monoclonal antibodies: 14C1 and 19G7. The IC₅₀s obtained through the ELISA assay were compared with those from the micro-test. The initial parameters of the synchronized samples used in the in vitro assays were a parasitaemia of 0.5% and haematocrit of 1%, with an incubation period of 22 hours at 36.5°C. pLDH detection using a 14C1 coating at 10 μg/ml and 19G7 at 2.5 × 10⁻³ μg/ml provided good readouts of optical densities with low background in negative controls and specific detection levels for all parasite stages. IC₅₀s values derived from the ELISA assay for artesunate, chloroquine, amodiaquine and quinine were: 15, 7, 2, and 144 nM, respectively. When artesunate and chloroquine IC₅₀s were evaluated using the micro-test similar values were obtained. This ELISA-based in vitro drug assay is easy to implement, fast, and avoids the use radioisotopes or expensive equipment. The utility of this simple assay for screening anti-malarial drug activity against P. berghei in vitro is demonstrated.
Darkoh, Charles; Kaplan, Heidi B; Dupont, Herbert L
2011-08-01
The incidence of Clostridium difficile infection (CDI) has been increasing within the last decade. Pathogenic strains of C. difficile produce toxin A and/or toxin B, which are important virulence factors in the pathogenesis of this bacterium. Current methods for diagnosing CDI are mostly qualitative tests that detect either the bacterium or the toxins. We have developed an assay (Cdifftox activity assay) to detect C. difficile toxin A and B activities that is quantitative and cost-efficient and utilizes a substrate that is stereochemically similar to the native substrate of the toxins (UDP-glucose). To characterize toxin activity, toxins A and B were purified from culture supernatants by ammonium sulfate precipitation and chromatography through DEAE-Sepharose and gel filtration columns. The activities of the final fractions were quantitated using the Cdifftox activity assay and compared to the results of a toxin A- and B-specific enzyme-linked immunosorbent assay (ELISA). The affinity for the substrate was >4-fold higher for toxin B than for toxin A. Moreover, the rate of cleavage of the substrate was 4.3-fold higher for toxin B than for toxin A. The optimum temperature for both toxins ranged from 35 to 40°C at pH 8. Culture supernatants from clinical isolates obtained from the stools of patients suspected to be suffering from CDI were tested using the Cdifftox activity assay, and the results were compared to those of ELISA and PCR amplification of the toxin genes. Our results demonstrate that this new assay is comparable to the current commercial ELISA for detecting the toxins in the samples tested and has the added advantage of quantitating toxin activity.
Okamura, Keisuke; Okuda, Tetsu; Shirai, Kazuyuki; Urata, Hidenori
2018-01-01
The aim of the present study was to establish a convenient clinically applicable assay method for chymase-dependent angiotensin II forming activity of circulating mononuclear leukocytes (CML), which was potentially a marker of tissue chymase activity. Using this method, association between CML chymase activity and clinical parameters was determined. Cardiovascular outpatients (n = 170) without taking antihypertensive medication were recruited. An ELISA for chymase-dependent angiotensin II-forming activity in CML was established using Nma /Dnp-modified angiotensin I. Logistic regression analysis revealed that age and male gender were significant independent determinants of the increased CML chymase activity. After adjustment by age and gender, the CML chymase activity was positively correlated with systolic blood pressure, pulse rate, and the brain natriuretic peptide level. The relation between blood pressure and CML chymase activity suggests that it might reflect that increased tissue chymase activity contributes to systemic high blood pressure and heart rate because plasma chymase is inactive due to inhibitory plasma inhibitors.
Tan, Weiming; Huang, Yuan; Nan, Tiegui; Xue, Changguo; Li, Zhaohu; Zhang, Qingchuan; Wang, Baomin
2010-01-15
Development of microcantilever biosensors for small molecules was exemplified with the beta-adrenergic agonist clenbuterol and the antibiotic chloramphenicol. In this paper, antibody sulfhydrylation and protein A were used to modify the microcantilever Au surface, and the antibody activities on the microcantilever were evaluated with direct competitive enzyme-linked immunosorbent assay (dcELISA). The activity of the antibodies immobilized on the microcantilever via protein A was 1.7-fold of that via the sulfhydrylation reagent 2-iminothiolane hydrochloride. A microcantilever immunosensor method with protein A as the functionalization reagent was established to detect the residues of clenbuterol and chloramphenicol at limits of detection (LOD) of approximately 0.1 and 0.2 ng/mL, respectively. Such LODs were better than that of the corresponding dcELISAs. The concentration of clenbuterol in a fortified feed sample detected with the microcantilever immunosensor after thorough extraction and purification agreed well with that detected with the dcELISA. Protein A showed to be simple and reproducible for functionalization of the antibodies on the Au surface and, thus, has common application values in microcantilever immunosensor development. The results suggest that microcantilever immunosensors be suitable for detection of small molecules, and the assay sensitivity is mainly related to the quality and activities of the antibodies.
Detection of fish antigens aerosolized during fish processing using newly developed immunoassays.
Lopata, Andreas L; Jeebhay, Mohamed F; Reese, Gerald; Fernandes, Joshua; Swoboda, Ines; Robins, Thomas G; Lehrer, Samuel B
2005-09-01
Aerosolization of fish proteins during seafood processing has been identified as a potential route for allergic sensitization and occupational asthma among workers involved in high-risk activities. The aim of this study was to develop immunological assays for the quantification of aerosolized fish antigens in a fish-processing factory. Polyclonal antibodies to the main fish species processed in the factory (anchovy and pilchard) were generated in rabbits and compared by ELISA inhibition assay and immunoblotting. These antisera were utilized to develop ELISA assays for the detection of fish antigens. The ELISA inhibition assays were evaluated by analyzing environmental air samples collected from three areas in a fish-processing factory: pilchard canning, fish meal production and lobster processing. By immunoblotting, the rabbit polyclonal antibodies demonstrated IgG antibody binding patterns comparable with IgE antibodies of fish-sensitized patients, particularly in regard to the major fish allergens parvalbumins. The sensitivity of the fish-specific ELISA assays developed was 0.5 microg/ml. The ELISA inhibition assays were able to differentiate between the two different fish species of interest but did not recognize a crustacean species. Notable differences in exposure levels to canned pilchard and anchovy antigens were demonstrated in the three different working areas of the factory, with assays having a detection limit as low as 105 ng/m(3). These ELISA-based assays are sensitive and specific to quantify differential exposure levels to fish antigens produced during fish processing, making it possible to investigate exposure-disease response relationships among workers in this industry. Copyright (c) 2005 S. Karger AG, Basel.
Recke, Andreas; Regensburger, Ann-Katrin; Weigold, Florian; Müller, Antje; Heidecke, Harald; Marschner, Gabriele; Hammers, Christoph M; Ludwig, Ralf J; Riemekasten, Gabriela
2018-01-01
Systemic sclerosis (SSc) is a severe chronic autoimmune disease with high morbidity and mortality. Sera of patients with SSc contain a large variety of autoantibody (aab) reactivities. Among these are functionally active aab that bind to G protein-coupled receptors (GPCR) such as C-X-C motif chemokine receptor 3 (CXCR3) and 4 (CXCR4). Aab binding to the N-terminal portion of these two GPCRs have been shown to be associated with slower disease progression in SSc, especially deterioration of lung function. Aabs binding to GPCRs exhibit functional activities by stimulating or inhibiting GPCR signaling. The specific functional activity of aabs crucially depends on the epitopes they bind to. To identify the location of important epitopes on CXCR3 recognized by aabs from SSc patients, we applied an array of 36 overlapping 18-20mer peptides covering the entire CXCR3 sequence, comparing epitope specificity of SSc patient sera ( N = 32, with positive reactivity with CXCR3) to healthy controls ( N = 30). Binding of SSc patient and control sera to these peptides was determined by ELISA. Using a Bayesian model approach, we found increased binding of SSc patient sera to peptides corresponding to intracellular epitopes within CXCR3, while the binding signal to extracellular portions of CXCR3 was found to be reduced. Experimentally determined epitopes showed a good correspondence to those predicted by the ABCpred tool. To verify these results and to translate them into a novel diagnostic ELISA, we combined the peptides that represent SSc-associated epitopes into a single ELISA and evaluated its potential to discriminate SSc patients ( N = 31) from normal healthy controls ( N = 47). This ELISA had a sensitivity of 0.61 and a specificity of 0.85. Our data reveals that SSc sera preferentially bind intracellular epitopes of CXCR3, while an extracellular epitope in the N-terminal domain that appears to be target of aabs in healthy individuals is not bound by SSc sera. Based upon our results, we could devise a novel ELISA concept that may be helpful for monitoring of SSc patients.
Recke, Andreas; Regensburger, Ann-Katrin; Weigold, Florian; Müller, Antje; Heidecke, Harald; Marschner, Gabriele; Hammers, Christoph M.; Ludwig, Ralf J.; Riemekasten, Gabriela
2018-01-01
Systemic sclerosis (SSc) is a severe chronic autoimmune disease with high morbidity and mortality. Sera of patients with SSc contain a large variety of autoantibody (aab) reactivities. Among these are functionally active aab that bind to G protein-coupled receptors (GPCR) such as C-X-C motif chemokine receptor 3 (CXCR3) and 4 (CXCR4). Aab binding to the N-terminal portion of these two GPCRs have been shown to be associated with slower disease progression in SSc, especially deterioration of lung function. Aabs binding to GPCRs exhibit functional activities by stimulating or inhibiting GPCR signaling. The specific functional activity of aabs crucially depends on the epitopes they bind to. To identify the location of important epitopes on CXCR3 recognized by aabs from SSc patients, we applied an array of 36 overlapping 18-20mer peptides covering the entire CXCR3 sequence, comparing epitope specificity of SSc patient sera (N = 32, with positive reactivity with CXCR3) to healthy controls (N = 30). Binding of SSc patient and control sera to these peptides was determined by ELISA. Using a Bayesian model approach, we found increased binding of SSc patient sera to peptides corresponding to intracellular epitopes within CXCR3, while the binding signal to extracellular portions of CXCR3 was found to be reduced. Experimentally determined epitopes showed a good correspondence to those predicted by the ABCpred tool. To verify these results and to translate them into a novel diagnostic ELISA, we combined the peptides that represent SSc-associated epitopes into a single ELISA and evaluated its potential to discriminate SSc patients (N = 31) from normal healthy controls (N = 47). This ELISA had a sensitivity of 0.61 and a specificity of 0.85. Our data reveals that SSc sera preferentially bind intracellular epitopes of CXCR3, while an extracellular epitope in the N-terminal domain that appears to be target of aabs in healthy individuals is not bound by SSc sera. Based upon our results, we could devise a novel ELISA concept that may be helpful for monitoring of SSc patients. PMID:29623076
Schnitzius, J M; Hill, N S; Thompson, C S; Craig, A M
2001-05-01
Ergot alkaloids present in endophyte-infected (E+) tall fescue cause fescue toxicosis and other toxic effects in livestock that consume infected plant tissue, leading to significant financial losses in livestock production each year. The predominant method currently in use for quantifying ergot alkaloid content in plant tissue is through high-performance liquid chromatography (HPLC), which quantifies the amount of ergovaline, one of many ergot alkaloids in E+ plant tissue. The enzyme-linked immunosorbent assay (ELISA) method used in this study detects quantities of nonspecific ergot alkaloids and therefore accounts for greater amounts of the total ergot alkaloid content in E+ tissue than does HPLC. The ELISA can also be used to more expediently analyze a larger number of forage samples without sophisticated and costly analytical equipment and therefore could be more desirable in a diagnostic setting. The purpose of this study was to evaluate the between-day and within-run variability of the ELISA and to determine the binding efficiency of 6 ergot alkaloids to the 15F3.E5 antibody used in the competitive ELISA to ascertain its feasibility as a quick analysis tool for ergot alkaloids. Straw samples had an average coefficient of variation (CV) for concentration of 10.2% within runs and 18.4% between runs, and the seed samples had an average CV for concentration of 13.3% within runs and 24.5% between runs. The grass tissue-based lysergic acid standard curve calculated from the ELISA had an average r2 of 0.99, with a CV of 2.1%. Ergocryptine, ergocristine, ergocornine, and ergotamine tartrate did not bind strongly to the 15F3.E5 antibody because of the presence of large side groups on these molecules, which block their binding to the antibody, whereas ergonovine and ergonovine maleate were bound much more efficiently because of their structural similarity to lysergic acid. Clarified rumen fluid was tested as an additional matrix for use in the ergot alkaloid competitive ELISA to determine whether future livestock metabolism experiments on the postingestion fate of ergot alkaloids in ruminants could utilize this assay as a quick screening tool for the presence of nonspecific ergot alkaloids in rumen fluid. HPLC and ELISA procedures were compared for their ability in determining ergot alkaloid toxicity based on the repeatability of the procedures and on the specific compounds they measure. The ratio of ELISA concentration to HPLC concentration (ergovaline) varied from 2.00 to 2.81 in seed samples and from 0.62 to 8.66 in straw samples, showing no consistent pattern between the 2 methods. Based on the lack of data at present for the identity of the toxin causing endophyte toxicosis and the lack of agreement between the ergovaline HPLC and ELISA analyses for ergot alkaloids, each method is equally valid as an indicator of toxicityand is the best means for determining the quantity of the specific toxin(s) they measure.
Miescher, S M; Huber, T M; Kühne, M; Lieby, P; Snydman, D R; Vensak, J L; Berger, M
2015-07-01
To evaluate standard intravenous immunoglobulin (IVIG) as an alternative to intravenous cytomegalovirus hyperimmune immunoglobulin (CMVIG) for prophylaxis and therapy of cytomegalovirus (CMV) disease, we measured the ELISA and neutralizing titres of CMV-specific antibodies in CMVIG and IVIG preparations. Anti-CMV-IgG ELISA and neutralizing titres (fibroblast-based test) in CMVIG CG (Cytogam®, n = 20), CMVIG CT (Cytotect® CP, n = 3), IVIG P (Privigen®, n = 32) and IVIG K/G (Kiovig®/Gammagard®, n = 5) were compared, and IgG subclasses 1-4 were determined by nephelometry. Cytomegalovirus hyperimmune immunoglobulins contained more than fourfold higher CMV ELISA and CMV-neutralizing activity per gram of IgG than the standard IVIGs. Pooled data for all four products showed a significant correlation between anti-CMV-IgG ELISA and neutralizing titres (r = 0·93, P < 0·001). There was a good correlation between the IgG3 content and CMV-neutralizing antibodies amongst lots of CMVIGs (r = 0·91, P = 0·01), but this did not extend to the IVIGs. CMVIG CG contained the highest CMV-neutralizing activity (3497 ± 395 PEIU/g IgG) of any product tested. The higher anti-CMV neutralization capacity of CMVIG per gram of IgG vs. standard IVIG suggests that standard IVIGs are not equivalent to or interchangeable with CMVIG. © 2015 The Authors. Vox Sanguinis published by John Wiley & Sons Ltd on behalf of International Society of Blood Transfusion.
Ching, W.-M.; Wang, H.; Eamsila, C.; Kelly, D. J.; Dasch, G. A.
1998-01-01
The variable 56-kDa major outer membrane protein of Orientia tsutsugamushi is the immunodominant antigen in human scrub typhus infections. The gene encoding this protein from Karp strain was cloned into the expression vector pET11a. The recombinant protein (r56) was expressed as a truncated nonfusion protein (amino acids 80 to 456 of the open reading frame) which formed an inclusion body when expressed in Escherichia coli BL21. Refolded r56 was purified and compared to purified whole-cell lysate of the Karp strain of O. tsutsugamushi by immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for reactivity with rabbit sera prepared against eight antigenic prototypes of O. tsutsugamushi as well as several other species of Rickettsiales and nonrickettsial antigens. Refolded r56 exhibited broad reactivity with the rabbit antisera against the Orientia prototypes, and the ELISA reactions with the r56 and Karp whole-cell lysate antigens correlated well (r = 0.81, n = 22, sensitivity compared to that of standard ELISA of 91%). Refolded r56 did not react with most antisera against other rickettsial species or control antigens (specificity = 92%, n = 13) using a positive cutoff value determined with eight uninfected rabbit sera. Refolded r56 was evaluated further by ELISA, using 128 sera obtained from patients with suspected scrub typhus from Korat, Thailand, and 74 serum specimens from healthy Thai soldiers. By using the indirect immunoperoxidase assay as the reference assay, the recombinant antigen exhibited a sensitivity and specificity of 93% or greater for detection of both IgG and IgM in the ELISA at 1:400 serum dilution. These results strongly suggest that purified r56 is a suitable candidate for replacing the density gradient-purified, rickettsia-derived, whole-cell antigen currently used in the commercial dipstick assay available in the United States. PMID:9665960
Ching, W M; Wang, H; Eamsila, C; Kelly, D J; Dasch, G A
1998-07-01
The variable 56-kDa major outer membrane protein of Orientia tsutsugamushi is the immunodominant antigen in human scrub typhus infections. The gene encoding this protein from Karp strain was cloned into the expression vector pET11a. The recombinant protein (r56) was expressed as a truncated nonfusion protein (amino acids 80 to 456 of the open reading frame) which formed an inclusion body when expressed in Escherichia coli BL21. Refolded r56 was purified and compared to purified whole-cell lysate of the Karp strain of O. tsutsugamushi by immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) for reactivity with rabbit sera prepared against eight antigenic prototypes of O. tsutsugamushi as well as several other species of Rickettsiales and nonrickettsial antigens. Refolded r56 exhibited broad reactivity with the rabbit antisera against the Orientia prototypes, and the ELISA reactions with the r56 and Karp whole-cell lysate antigens correlated well (r = 0.81, n = 22, sensitivity compared to that of standard ELISA of 91%). Refolded r56 did not react with most antisera against other rickettsial species or control antigens (specificity = 92%, n = 13) using a positive cutoff value determined with eight uninfected rabbit sera. Refolded r56 was evaluated further by ELISA, using 128 sera obtained from patients with suspected scrub typhus from Korat, Thailand, and 74 serum specimens from healthy Thai soldiers. By using the indirect immunoperoxidase assay as the reference assay, the recombinant antigen exhibited a sensitivity and specificity of 93% or greater for detection of both IgG and IgM in the ELISA at 1:400 serum dilution. These results strongly suggest that purified r56 is a suitable candidate for replacing the density gradient-purified, rickettsia-derived, whole-cell antigen currently used in the commercial dipstick assay available in the United States.
Zajicek, James L.; Tillitt, Donald E.; Huckins, James N.; Petty, Jimmie D.; Potts, Michael E.; Nardone, David A.
1996-01-01
Determination of PCBs in biological tissue extracts by enzyme-linked immunosorbent assays (ELISAs) can be problematic, since the hydrophobic solvents used for their extraction and isolation from interfering biochemicals have limited compatibility with the polar solvents (e.g. methanol/water) and the immunochemical reagents used in ELISA. Our studies of these solvent effects indicate that significant errors can occur when microliter volumes of PCB containing extracts, in hydrophobic solvents, are diluted directly into methanol/water diluents. Errors include low recovery and excess variability among sub-samples taken from the same sample dilution. These errors are associated with inhomogeneity of the dilution, which is readily visualized by the use of a hydrophobic dye, Solvent Blue 35. Solvent Blue 35 is also used to visualize the evaporative removal of hydrophobic solvent and the dissolution of the resulting PCB/dye residue by pure methanol and 50% (v/v) methanol/water, typical ELISA diluents. Evaporative removal of isooctane by an ambient temperature nitrogen purge with subsequent dissolution in 100% methanol gives near quantitative recovery of model PCB congeners. We also compare concentrations of total PCBs from ELISA (ePCB) to their corresponding concentrations determined from capillary gas chromatography (GC) in selected fish sample extracts and dialysates of semipermeable membrane device (SPMD) passive samplers using an optimized solvent exchange procedure. Based on Aroclor 1254 calibrations, ePCBs (ng/mL) determined in fish extracts are positively correlated with total PCB concentrations (ng/mL) determined by GC: ePCB = 1.16 * total-cPCB - 5.92. Measured ePCBs (ng/3 SPMDs) were also positively correlated (r2 = 0.999) with PCB totals (ng/3 SPMDs) measured by GC for dialysates of SPMDs: ePCB = 1.52 * total PCB - 212. Therefore, this ELISA system for PCBs can be a rapid alternative to traditional GC analyses for determination of PCBs in extracts of biota or in SPMD dialysates.
Rapid Enhanced MM3-COPRO ELISA for Detection of Fasciola Coproantigens.
Martínez-Sernández, Victoria; Orbegozo-Medina, Ricardo A; González-Warleta, Marta; Mezo, Mercedes; Ubeira, Florencio M
2016-07-01
ELISA-based methods of detecting Fasciola cathepsins in feces are powerful techniques for diagnosing infections by F. hepatica and F. gigantica. In the last decade, the in-house MM3-COPRO ELISA and its commercial version BIO K 201 (BIO X Diagnostics, Belgium) have been recognized as useful tools for detecting early infections by such trematodes and for monitoring the efficacy of anthelmintic treatments in human and animal species, as they provide some advantages over classic fecal egg counts. However, the sensitivity of MM3-COPRO ELISA can sometimes be compromised by the high variability in the concentration of cathepsins in fecal samples throughout the biological cycle of Fasciola (mainly in cattle) and by differences in the between-batch performance of peroxidase-labeled anti-mouse IgG polyclonal antibodies. To prevent such problems, we investigated whether the incorporation of a commercial streptavidin-polymerized horseradish peroxidase conjugate, in order to reveal bound biotinylated monoclonal antibody MM3, can improve the sensitivity of the MM3-COPRO ELISA. We observed that inclusion of this reagent shifted the previous detection limit of the assay from 0.6 ng/mL to 150 pg/mL and that the modified test is able to identify infection in cows harboring only one fluke. Moreover, we demonstrated that maximal OD values can be achieved with short incubations (30 min each step) at RT with shaking, rather than standard incubations, which significantly accelerates the diagnostic procedure. Finally, we did not find a significant correlation between coproantigen concentration and parasite burden in cattle, which may be due to the low parasite burden (1-10 adult flukes) of the animals used in the present study. As the usefulness of the classic MM3-COPRO test for detecting animal and human infections has already been demonstrated, it is expected that the improvements reported in this study will add new insights into the diagnosis and control of fasciolosis.
Rapid Enhanced MM3-COPRO ELISA for Detection of Fasciola Coproantigens
Martínez-Sernández, Victoria; Orbegozo-Medina, Ricardo A.; González-Warleta, Marta; Mezo, Mercedes; Ubeira, Florencio M.
2016-01-01
ELISA-based methods of detecting Fasciola cathepsins in feces are powerful techniques for diagnosing infections by F. hepatica and F. gigantica. In the last decade, the in-house MM3-COPRO ELISA and its commercial version BIO K 201 (BIO X Diagnostics, Belgium) have been recognized as useful tools for detecting early infections by such trematodes and for monitoring the efficacy of anthelmintic treatments in human and animal species, as they provide some advantages over classic fecal egg counts. However, the sensitivity of MM3-COPRO ELISA can sometimes be compromised by the high variability in the concentration of cathepsins in fecal samples throughout the biological cycle of Fasciola (mainly in cattle) and by differences in the between-batch performance of peroxidase-labeled anti-mouse IgG polyclonal antibodies. To prevent such problems, we investigated whether the incorporation of a commercial streptavidin-polymerized horseradish peroxidase conjugate, in order to reveal bound biotinylated monoclonal antibody MM3, can improve the sensitivity of the MM3-COPRO ELISA. We observed that inclusion of this reagent shifted the previous detection limit of the assay from 0.6 ng/mL to 150 pg/mL and that the modified test is able to identify infection in cows harboring only one fluke. Moreover, we demonstrated that maximal OD values can be achieved with short incubations (30 min each step) at RT with shaking, rather than standard incubations, which significantly accelerates the diagnostic procedure. Finally, we did not find a significant correlation between coproantigen concentration and parasite burden in cattle, which may be due to the low parasite burden (1–10 adult flukes) of the animals used in the present study. As the usefulness of the classic MM3-COPRO test for detecting animal and human infections has already been demonstrated, it is expected that the improvements reported in this study will add new insights into the diagnosis and control of fasciolosis. PMID:27438470
Decline of maternal antibodies to small ruminant lentivirus in goat kids.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Reczyńska, Daria; Bagnicka, Emilia; Kaba, Jarosław
2018-06-06
We carried out this study to determine for how long small ruminant lentivirus (SRLV)-specific antibodies can be detected by three commercial ELISA kits in goat kids after suckling infected does in field conditions. Forty-one kids born to SRLV-seropositive asymptomatic does were blood sampled prior to colostrum consumption, and then weekly for 6 months in total. The sera were screened with three commercial ELISA kits: whole-virus ELISA (wELISA), recombinant transmembrane and capsid antigen ELISA (TM/CA-ELISA), and surface antigen ELISA (SU-ELISA). All but one kid were seronegative in all three ELISAs right after birth. At the age of 1 week all kids turned seropositive in wELISA, 39 kids (95%) in TM/CA-ELISA, and 35 kids (85%) in SU-ELISA. All seropositive kids turned seronegative in wELISA by the 15th week, and in SU-ELISA by the 19th week (median of 8 weeks in both ELISA), whereas in TM/CA-ELISA five kids (13% of 39 initially seropositive) were still seropositive at the age of 6 months (median of 11 weeks). Antibody levels at the age of 1 week proved significantly linked to the duration of maternal antibodies in all three ELISAs and could be employed to predict for how long maternal antibodies would remain detectable. © 2018 Japanese Society of Animal Science.
Sugden, E A; Stilwell, K; Rohonczy, E B; Martineau, P
1997-01-01
A competitive enzyme-linked immunosorbent assay (C-ELISA) using M. bovis BCG Tokyo culture filtrate as antigen and anti-MPB70 4C3/17 monoclonal antibody was developed for use in multiple animal species. An analysis of the C-ELISA data for cattle and bison serum panels revealed specificities of 68% to 85% and sensitivities of 85% to 89%. Receiver operator characteristics (ROC) of this data revealed areas of 81% to 92% for C-ELISA and demonstrated that C-ELISA as well as the indirect ELISA protocols, MPB70-ELISA and LAM-ELISA, discriminate M. bovis infected animals from non-infected animals for these particular panels. The kappa statistic values for agreement beyond chance between C-ELISA and MPB70-ELISA were determined after ELISA cutoffs were adjusted to minimize false positives. There were poor to excellent agreements between C-ELISA and MPB70-ELISA in all species tested (Bovidae, Cervidae, and Camelidae) that were consistently higher than the kappa statistic between C-ELISA and LAM-ELISA. The humoral response to one antigen and little or no response to the other in many animals argued for a parallel interpretation of C-ELISA and LAM-ELISA to increase sensitivity. PMID:9008794
Shephard, R W; Morton, J M
2018-01-01
To determine the sensitivity (Se) and specificity (Sp) of pregnancy diagnosis using transrectal ultrasonography and an ELISA for pregnancy-associated glycoprotein (PAG) in milk, in lactating dairy cows in seasonally calving herds approximately 85-100 days after the start of the herd's breeding period. Paired results were used from pregnancy diagnosis using transrectal ultrasonography and ELISA for PAG in milk carried out approximately 85 and 100 days after the start of the breeding period, respectively, from 879 cows from four herds in Victoria, Australia. A Bayesian latent class model was used to estimate the proportion of cows pregnant, the Se and Sp of each test, and covariances between test results in pregnant and non-pregnant cows. Prior probability estimates were defined using beta distributions for the expected proportion of cows pregnant, Se and Sp for each test, and covariances between tests. Markov Chain Monte Carlo iterations identified posterior distributions for each of the unknown variables. Posterior distributions for each parameter were described using medians and 95% probability (i.e. credible) intervals (PrI). The posterior median estimates for Se and Sp for each test were used to estimate positive predictive and negative predictive values across a range of pregnancy proportions. The estimate for proportion pregnant was 0.524 (95% PrI = 0.485-0.562). For pregnancy diagnosis using transrectal ultrasonography, Se and Sp were 0.939 (95% PrI = 0.890-0.974) and 0.943 (95% PrI = 0.885-0.984), respectively; for ELISA, Se and Sp were 0.963 (95% PrI = 0.919-0.990) and 0.870 (95% PrI = 0.806-0.931), respectively. The estimated covariance between test results was 0.033 (95% PrI = 0.008-0.046) and 0.035 (95% PrI = 0.018-0.078) for pregnant and non-pregnant cows, respectively. Pregnancy diagnosis results using transrectal ultrasonography had a higher positive predictive value but lower negative predictive value than results from the ELISA across the range of pregnancy proportions assessed. Pregnancy diagnosis using transrectal ultrasonography and ELISA for PAG in milk had similar Se but differed in predictive values. Pregnancy diagnosis in seasonally calving herds around 85-100 days after the start of the breeding period using the ELISA is expected to result in a higher negative predictive value but lower positive predictive value than pregnancy diagnosis using transrectal ultrasonography. Thus, with the ELISA, a higher proportion of the cows with negative results will be non-pregnant, relative to results from transrectal ultrasonography, but a lower proportion of cows with positive results will be pregnant.
Therapeutic evaluation of GM2 gangliosidoses by ELISA using anti-GM2 ganglioside antibodies.
Tsuji, Daisuke; Higashine, Yukari; Matsuoka, Kazuhiko; Sakuraba, Hitoshi; Itoh, Kohji
2007-03-01
GM2 gangliosidoses, including Tay-Sachs disease, Sandhoff disease and the AB variant, comprise deficiencies of beta-hexosaminidase isozymes and GM2 ganglioside activator protein associated with accumulation of GM2 ganglioside (GM2) in lysosomes and neurosomatic clinical manifestations. A simple assay system for intracellular quantification of GM2 is required to evaluate the therapeutic effects on GM2-gangliosidoses. We newly established a cell-ELISA system involving anti-GM2 monoclonal antibodies for measuring GM2 storage in fibroblasts from Tay-Sachs and Sandhoff disease patients. We succeeded in detecting the corrective effect of enzyme replacement on elimination of GM2 in the cells with this ELISA system. This simple and sensitive system should be useful as additional diagnosis tool as well as therapeutic evaluation of GM2 gangliosidoses.
Rossi, E A; Shepard, S R; Poyer, J C; Hartmann, J X
1992-06-01
Balb/c mice were immunized with albumin purified from sailfish (Istiophorus albicans) serum. Hybridomas were produced and screened by ELISA for reactivity with the purified albumins of sailfish, blue marlin (Makaira nigricans) and white marlin (Tetrapturus albidus). Monoclonal antibodies (MAbs) from 16 different clones exhibited activity against sailfish albumin. Thirteen of the MAbs showed cross-reactivity with the marlin species. Three MAbs exhibited distinct specificity for sailfish albumin. One of these species specific MAbs (M2D1) was conjugated to horseradish peroxidase (HRP) in order to construct an ELISA for identification of sailfish from serum. The ELISA for sailfish correctly identified eight sailfish from 26 billfish serum samples. The MAb-peroxidase conjugate was highly specific toward sailfish in that no reaction against heterologous species was detected.
Elisa Miller Photo of Elisa Miller Elisa Link-Miller Researcher III-Chemistry Elisa.Miller@nrel.gov | 303-384-6777 Dr. Elisa Miller-Link studies the surface of semiconductors that are applicable for , and other nanocrystalline films. Elisa came to NREL in 2013 as an NREL Director's Fellowship recipient
Ravi, Deepthi; Prabhu, S Smitha; Rao, Raghavendra; Balachandran, C; Bairy, Indira
2017-01-01
Background: Pemphigus is an acquired immunobullous disorder in which antibodies are directed against epidermal cadherins. Despite the commercial availability and less cost of enzyme-linked immunosorbent assays (ELISAs) to detect antidesmoglein 1 (Dsg1) and anti-Dsg3, immunofluorescence is still widely used for confirmation of diagnosis. Aims: (1) To compare the usefulness of indirect immunofluorescence (IIF) and ELISA tests in the diagnosis of pemphigus. (2) To find the clinical correlation between the tests and severity of the disease. Materials and Methods: Sixty-one patients (27 women and 34 men, age distribution from 20 to 75) were clinically diagnosed as pemphigus (pemphigus foliaceus - 11, pemphigus vulgaris - 50) and were recruited for the study. IIF and Dsg ELISA were performed and the findings were compared with each other and with the pemphigus area activity score. Data were entered in SPSS and were analyzed using Kruskal–Wallis test. Results: There was a moderate positive correlation between the cutaneous score and Dsg1 titer, and mucosal score and Dsg3 titer. The titer of IIF showed statistically significant positive correlation with the cutaneous score but not the mucosal score. Dsg ELISA showed higher sensitivity (90.2%) than IIF (75.4%) in the diagnosis of pemphigus. Conclusions: Dsg ELISA is a more sensitive method than IIF and shows more correlation with the disease severity. PMID:28400637
Helling, T S; Edwards, C A; Helling, T S; Chang, C C; Hodges, M C; Dhar, A; VanWay, C
1999-09-01
Accelerated hepatic apoptosis was first described in portal vein-ligated livers but has since been reported in a variety of liver injuries. Because porto-prival states can induce apoptosis we sought to determine whether transient ischemic periods followed by reperfusion would trigger such cell death. The cytokines TNF-alpha and TGF-beta are known to facilitate apoptosis and are released in response to a number of stimuli including ischemia. We also investigated alterations in plasma and tissue levels of these cytokines which might lend support to their role in increased apoptotic activity following ischemia/reperfusion. Female pigs were used as the experimental model. Inflow occlusion of portal and hepatic arterial blood was performed to a portion of the swine liver directing the entire splanchnic flow to the remaining hepatic lobes for a period of 2 h. The livers were then reperfused and plasma and tissue samples taken for determination of apoptotic activity utilizing cell death immunoperoxidase staining of 3'-OH DNA ends generated by fragmentation and ELISA assay of histone-associated DNA fragments. Plasma and tissue levels of TNF-alpha and plasma levels of TGF-beta were determined by ELISA assay. An increase in apoptotic activity following reperfusion was seen at Day 2 and Day 4 compared to preischemic values by the cell death stain. The ELISA cell death assay showed an increase in apoptotic activity at 60 min, Day 2, and Day 4. Moreover, the ELISA cell death assay showed enhanced apoptotic activity in "hyperperfused" hepatic lobes compared to preischemic, or resting, liver. This was also observed when compared to sham-operated animals. Surprisingly, there was no detectable increase in plasma TNF-alpha or TGF-beta levels following ischemia/reperfusion, although homogenized liver TNF-alpha levels were increased at 60 min and Day 2 following reperfusion. We conclude that transient hepatic inflow occlusion followed by reperfusion can induce increased apoptotic activity in the swine model. Furthermore, increased apoptotic activity also occurs in the hyperperfused liver raising the possibility of a locally active factor or global hepatic expression of receptor activity in response to ischemia/reperfusion. This period of ischemia/reperfusion did not produce a detectable increase in circulating cytokine levels, and accelerated apoptosis could not be linked to heightened TNF-alpha or TGF-beta plasma activity. Higher tissue levels of TNF-alpha could reflect enhanced binding to TNF cell surface receptors or amplified receptor expression. Copyright 1999 Academic Press.
Lu, Mei; Jin, Yuan; Ballmer-Weber, Barbara; Goodman, Richard E
2018-02-01
Prior to commercialization, genetically modified (GM) crops are evaluated to determine the allergenicity of the newly expressed protein. Some regulators require an evaluation of endogenous allergens in commonly allergenic crops including soybean to determine if genetic transformation increased endogenous allergen concentrations, even asking for IgE testing using sera from individual sensitized subjects. Little is known about the variability of the expression of endogenous allergens among non-GM varieties or under different environmental conditions. We tested IgE binding to endogenous allergenic proteins in an experimental non-commercial GM line, a non-GM near-isoline control, and five non-GM commercial soybean lines replicated at three geographically separated locations. One-dimensional (1D) and two-dimensional (2D) immunoblotting and ELISA were performed using serum or plasma from eleven soybean allergic patients. The results of immunoblots and ELISA showed no significant differences in IgE binding between the GM line and its non-GM near-isoline control. However, some distinct differences in IgE binding patterns were observed among the non-GM commercial soybean lines and between different locations, highlighting the inherent variability in endogenous allergenic proteins. Understanding the potential variability in the levels of endogenous allergens is necessary to establish a standard of acceptance for GM soybeans compared to non-GM soybean events and lines. Copyright © 2018. Published by Elsevier Ltd.
Allen, Camryn D; Robbins, Michelle N; Eguchi, Tomoharu; Owens, David W; Meylan, Anne B; Meylan, Peter A; Kellar, Nicholas M; Schwenter, Jeffrey A; Nollens, Hendrik H; LeRoux, Robin A; Dutton, Peter H; Seminoff, Jeffrey A
2015-01-01
Determining sex ratios of endangered populations is important for wildlife management, particularly species subject to sex-specific threats or that exhibit temperature-dependent sex determination. Sea turtle sex is determined by incubation temperature and individuals lack external sex-based traits until sexual maturity. Previous research utilized serum/plasma testosterone radioimmunoassays (RIA) to determine sex in immature/juvenile sea turtles. However, there has been a growing application of enzyme-linked immunosorbent assay (ELISA) for wildlife endocrinology studies, but no study on sea turtles has compared the results of ELISA and RIA. This study provides the first sex ratio for a threatened East Pacific green sea turtle (Chelonia mydas) foraging aggregation, a critical step for future management of this species. Here, we validate a testosterone ELISA and compare results between RIA and ELISA of duplicate samples. The ELISA demonstrated excellent correspondence with the RIA for providing testosterone concentrations for sex determination. Neither assay proved reliable for predicting the sex of reproductively active females with increased testosterone production. We then applied ELISA to examine the sex ratio of 69 green turtles foraging in San Diego Bay, California. Of 45 immature turtles sampled, sex could not be determined for three turtles because testosterone concentrations fell between the ranges for either sex (females: 4.1-113.1 pg/mL, males: 198.4-2,613.0 pg/mL) and these turtles were not subsequently recaptured to enable sex determination; using a Bayesian model to predict probabilities of turtle sex we predicted all three 'unknowns' were female (> 0.86). Additionally, the model assigned all turtles with their correct sex (if determined at recapture) with 100% accuracy. Results indicated a female bias (2.83F:1M) among all turtles in the aggregation; when focusing only on putative immature turtles the sex ratio was 3.5F:1M. With appropriate validation, ELISA sexing could be applied to other sea turtle species, and serve as a crucial conservation tool.
Allen, Camryn D.; Robbins, Michelle N.; Eguchi, Tomoharu; Owens, David W.; Meylan, Anne B.; Meylan, Peter A.; Kellar, Nicholas M.; Schwenter, Jeffrey A.; Nollens, Hendrik H.; LeRoux, Robin A.; Dutton, Peter H.; Seminoff, Jeffrey A.
2015-01-01
Determining sex ratios of endangered populations is important for wildlife management, particularly species subject to sex-specific threats or that exhibit temperature-dependent sex determination. Sea turtle sex is determined by incubation temperature and individuals lack external sex-based traits until sexual maturity. Previous research utilized serum/plasma testosterone radioimmunoassays (RIA) to determine sex in immature/juvenile sea turtles. However, there has been a growing application of enzyme-linked immunosorbent assay (ELISA) for wildlife endocrinology studies, but no study on sea turtles has compared the results of ELISA and RIA. This study provides the first sex ratio for a threatened East Pacific green sea turtle (Chelonia mydas) foraging aggregation, a critical step for future management of this species. Here, we validate a testosterone ELISA and compare results between RIA and ELISA of duplicate samples. The ELISA demonstrated excellent correspondence with the RIA for providing testosterone concentrations for sex determination. Neither assay proved reliable for predicting the sex of reproductively active females with increased testosterone production. We then applied ELISA to examine the sex ratio of 69 green turtles foraging in San Diego Bay, California. Of 45 immature turtles sampled, sex could not be determined for three turtles because testosterone concentrations fell between the ranges for either sex (females: 4.1–113.1 pg/mL, males: 198.4–2,613.0 pg/mL) and these turtles were not subsequently recaptured to enable sex determination; using a Bayesian model to predict probabilities of turtle sex we predicted all three ‘unknowns’ were female (> 0.86). Additionally, the model assigned all turtles with their correct sex (if determined at recapture) with 100% accuracy. Results indicated a female bias (2.83F:1M) among all turtles in the aggregation; when focusing only on putative immature turtles the sex ratio was 3.5F:1M. With appropriate validation, ELISA sexing could be applied to other sea turtle species, and serve as a crucial conservation tool. PMID:26465620
Das, Sarita; Dileepan, T; Johnson, D R; Kaplan, E L; Patrick Cleary, P
2017-12-01
Among the four known Streptococcal nucleases comprising of DNase A, B, C and D; DNase B is the most common, and determination of the levels of antibody to DNase B (ADB) is often used to confirm a clinical diagnosis of Streptococcus pyogenes/group A Streptococcal (GAS) infection. The commonly used assays for antibodies that neutralize DNase B or streptolysin O activity use partially purified antigens that often fail to detect antibody changes subsequent to culture documented infections. Therefore, an enzyme-linked immunosorbent assay (ELISA) was developed employing his-tagged recombinant DNase B as plate antigen for comparison to the commonly used DNA methyl green micromethod (DMGM). DNAs from various Streptococcal species were screened for presence of dnaseB gene by PCR. Measurements of ADB in sera collected from subjects belonging to different ages, and ethnic groups were used to compare the two methods. dnaseB was not detected by PCR in DNA samples isolated from different strains of group B (GBS), C (GCS) and G (GGS) Streptococci. The ADB based ELISA proved to be highly sensitive and more responsive to changes in antibody concentration than DMGM. Use of recombinant DNase B eliminates the variability associated with the enzyme, partially purified from Streptococcal culture supernatants from various commercial sources and may provide a more reliable source of antigen to a wider group of laboratories concerned with GAS diagnosis. Copyright © 2017. Published by Elsevier B.V.
Designed Ankyrin Repeat Proteins: A New Approach to Mimic Complex Antigens for Diagnostic Purposes?
Hausammann, Stefanie; Vogel, Monique; Kremer Hovinga, Johanna A.; Lacroix-Desmazes, Sebastien; Stadler, Beda M.; Horn, Michael P.
2013-01-01
Inhibitory antibodies directed against coagulation factor VIII (FVIII) can be found in patients with acquired and congenital hemophilia A. Such FVIII-inhibiting antibodies are routinely detected by the functional Bethesda Assay. However, this assay has a low sensitivity and shows a high inter-laboratory variability. Another method to detect antibodies recognizing FVIII is ELISA, but this test does not allow the distinction between inhibitory and non-inhibitory antibodies. Therefore, we aimed at replacing the intricate antigen FVIII by Designed Ankyrin Repeat Proteins (DARPins) mimicking the epitopes of FVIII inhibitors. As a model we used the well-described inhibitory human monoclonal anti-FVIII antibody, Bo2C11, for the selection on DARPin libraries. Two DARPins were selected binding to the antigen-binding site of Bo2C11, which mimic thus a functional epitope on FVIII. These DARPins inhibited the binding of the antibody to its antigen and restored FVIII activity as determined in the Bethesda assay. Furthermore, the specific DARPins were able to recognize the target antibody in human plasma and could therefore be used to test for the presence of Bo2C11-like antibodies in a large set of hemophilia A patients. These data suggest, that our approach might be used to isolate epitopes from different sets of anti-FVIII antibodies in order to develop an ELISA-based screening assay allowing the distinction of inhibitory and non-inhibitory anti-FVIII antibodies according to their antibody signatures. PMID:23626669
Narvaez, Edgar; Berendsen, Jorge; Guzmán, Fanny; Gallardo, José A; Mercado, Luis
2010-01-01
Antimicrobial peptides (AMPs) are a pivotal component of innate immunity in lower vertebrates. The aim of this study was to develop an immunological method for quantifying AMPs in Salmo salar skin mucus. A known antimicrobial peptide derived from histone H1 previously purified and described from S. salar skin mucus (SAMP H1) was chemically synthesized and used to obtain antibodies for the quantification of the molecule via ELISA. Using skin mucus samples, a correlation of bacterial growth inhibition versus SAMP H1 concentration (ELISA) was established. The results provide the first evidence for quantifying the presence of active AMPs in the skin mucus of S. salar through the use of an immunological method. Copyright 2009 Elsevier Ltd. All rights reserved.
[Effect evaluation of three ELISA kits in detection of fasciolasis].
Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu
2013-04-01
To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.
Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene
2018-01-01
Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values < 0.05 were taken statistically significant. Stool and serum samples were collected from 201 dyspeptic patients and analysed. The sensitivity, specificity, positive and negative predictive values of the SD BIOLINE H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.
Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C
2012-12-21
Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.
Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru
2014-01-01
A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.
Rodríguez-López, M; Riezu-Boj, J I; Ruiz, M; Berasain, C; Civeira, M P; Prieto, J; Borrás-Cuesta, F
1999-03-01
The immunogenicity of variable regions of hepatitis C virus (HCV) proteins was studied by ELISA by using 543 synthetic peptides from 120 variable regions and 90 sera from HCV-infected patients. Some regions from certain genotypes were less immunogenic, or even non-immunogenic, compared with their equivalents in other genotypes. However, the mean recognition of all peptides from genotypes 1a, 1b and 3 by sera infected with genotypes 1a, 1b and 3, respectively, showed no significant differences, suggesting a similar overall immunogenicity of variable regions from these genotypes. Proteins NS4a, NS4b and NS5a were found to be the most immunogenic. Recognition of individual peptides by the sera of infected patients showed that the humoral response against HCV is patient-dependent. The work shows that 15-mer peptides may encompass several B-cell epitopes. These epitopes may lie in slightly different positions in different genotypes. Thirty-one percent of the 543 peptides were recognized by some of the 35 healthy donors. This may be a reflection of the large number of antigens to which they had been exposed, but it may also reflect a strategy of HCV to respond to immune pressure. After selection and modification, a set of 40 peptides was used to assess genotypes 1a, 1b, 1, 2 and 3 in the sera of HCV-infected patients, with sensitivities of 34.1, 48.5, 68.8, 58.3 and 48.9% and specificities of 100, 99.1, 97.1, 99.5 and 99%, respectively. The overall sensitivity and specificity for the assessment of genotypes 1, 2 and 3 were 64 and 98%, respectively.
Manickum, Thavrin; John, Wilson
2015-07-01
The availability of national test centers to offer a routine service for analysis and quantitation of some selected steroid hormones [natural estrogens (17-β-estradiol, E2; estrone, E1; estriol, E3), synthetic estrogen (17-α-ethinylestradiol, EE2), androgen (testosterone), and progestogen (progesterone)] in wastewater matrix was investigated; corresponding internationally used chemical- and immuno-analytical test methods were reviewed. The enzyme-linked immunosorbent assay (ELISA) (immuno-analytical technique) was also assessed for its suitability as a routine test method to quantitate the levels of these hormones at a sewage/wastewater treatment plant (WTP) (Darvill, Pietermaritzburg, South Africa), over a 2-year period. The method performance and other relevant characteristics of the immuno-analytical ELISA method were compared to the conventional chemical-analytical methodology, like gas/liquid chromatography-mass spectrometry (GC/LC-MS), and GC-LC/tandem mass spectrometry (MSMS), for quantitation of the steroid hormones in wastewater and environmental waters. The national immuno-analytical ELISA technique was found to be sensitive (LOQ 5 ng/L, LOD 0.2-5 ng/L), accurate (mean recovery 96%), precise (RSD 7-10%), and cost-effective for screening and quantitation of these steroid hormones in wastewater and environmental water matrix. A survey of the most current international literature indicates a fairly equal use of the LC-MS/MS, GC-MS/MS (chemical-analytical), and ELISA (immuno-analytical) test methods for screening and quantitation of the target steroid hormones in both water and wastewater matrix. Internationally, the observed sensitivity, based on LOQ (ng/L), for the steroid estrogens E1, E2, EE2, is, in decreasing order: LC-MSMS (0.08-9.54) > GC-MS (1) > ELISA (5) (chemical-analytical > immuno-analytical). At the national level, the routine, unoptimized chemical-analytical LC-MSMS method was found to lack the required sensitivity for meeting environmental requirements for steroid hormone quantitation. Further optimization of the sensitivity of the chemical-analytical LC-tandem mass spectrometry methods, especially for wastewater screening, in South Africa is required. Risk assessment studies showed that it was not practical to propose standards or allowable limits for the steroid estrogens E1, E2, EE2, and E3; the use of predicted-no-effect concentration values of the steroid estrogens appears to be appropriate for use in their risk assessment in relation to aquatic organisms. For raw water sources, drinking water, raw and treated wastewater, the use of bioassays, with trigger values, is a useful screening tool option to decide whether further examination of specific endocrine activity may be warranted, or whether concentrations of such activity are of low priority, with respect to health concerns in the human population. The achievement of improved quantitation limits for immuno-analytical methods, like ELISA, used for compound quantitation, and standardization of the method for measuring E2 equivalents (EEQs) used for biological activity (endocrine: e.g., estrogenic) are some areas for future EDC research.
Garritsen, H S; Probst-Kepper, M; Legath, N; Eberl, W; Samaniego, S; Woudenberg, J; Schuitemaker, J H N; Kroll, H; Gurney, D A; Moore, G W; Zehnder, J L
2014-04-01
Heparin-induced thrombocytopenia (HIT) is a life-threatening condition, in which the anticoagulant heparin, platelet factor 4 (PF4), and platelet-activating antibodies form complexes with prothrombotic properties. Laboratory tests to support clinical diagnosis are subdivided into functional, platelet activation assays, which lack standardization, or immunological assays, which have moderate specificity toward HIT. In this study, clinical performance of HITAlert, a novel in vitro diagnostic (IVD) registered platelet activation assay, was tested in a large cohort of HIT-suspected patients and compared with immunological assays. From 346 HIT-suspected patients (single center), clinical data including 4T pretest probability results, citrated platelet-poor plasmas, and sera were collected, allowing direct comparison of clinical observations with HITAlert results. HITAlert performance was compared with PF4 IgG ELISA (246 patients, three centers) and PF4 PaGIA (298 patients, single center). HITAlert showed high sensitivity (88.2%) and specificity (99.1%) when compared with clinical diagnosis. Agreement of HITAlert with PF4 ELISA- and PF4 PaGIA-positive patients is low (52.7 and 23.2%, respectively), while agreement with PF4 IgG ELISA- and PF4 PaGIA-negative patients is very high (98.1 and 99.1%, respectively). HITAlert performance is excellent when compared with clinical HIT diagnosis, making it a suitable assay for rapid testing of platelet activation due to anticoagulant therapy. © 2013 John Wiley & Sons Ltd.
Duffort, O; Calabozo, B; González, R; Carpizo, J A; Barber, D; Polo, F
2004-12-01
Pollen of Bermuda grass (Cynodon dactylon) is an important cause of pollinosis in many areas of the world. Most patients show sensitivity to the major allergen Cyn d 1, a glycoprotein composed of a number of isoforms with a molecular mass of 31-32 kDa. The aim of this work was to develop a monoclonal antibody (mAb)-based ELISA to quantify Cyn d 1, and to assess the correlation of the allergen content with the biological activity of C. dactylon pollen extracts. After fusion of myeloma cells with spleen cells from a BALB/c mouse immunized with C. dactylon pollen extract, Cyn d 1-specific mAbs secreting hybridomas were selected, and the antibodies characterized. One of them (4.4.1) was used as the capture antibody in an ELISA method for Cyn d 1 quantitation. An anti-Cyn d 1 rabbit serum was used as the second antibody. Cyn d 1 was purified by immunoaffinity chromatography with mAb 4.4.1, characterized, and used as the standard in the assay. The identity, purity and isoallergen composition of affinity-purified Cyn d 1 was confirmed by N-terminal amino acid sequencing, SDS-PAGE, Western blot and 2D electrophoresis. The Cyn d 1 ELISA is highly specific and sensitive, with a detection limit of 0.24 ng/ml and a linear range of 1.1-9.2 ng/ml. An excellent correlation was found when the content of Cyn d 1, measured in 16 different extracts, was compared with the allergenic activity of the same extracts determined by RAST inhibition. The results prove the usefulness of the Cyn d 1 ELISA for the standardization of C. dactylon-allergen products on the basis of major allergen content. 2004 S. Karger AG, Basel.
Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M
2018-01-01
Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily detected. Copyright © 2017 Elsevier B.V. All rights reserved.
Rapid Activation of Bone Morphogenic Protein 9 by Receptor-mediated Displacement of Pro-domains*
Kienast, Yvonne; Jucknischke, Ute; Scheiblich, Stefan; Thier, Martina; de Wouters, Mariana; Haas, Alexander; Lehmann, Christian; Brand, Verena; Bernicke, Dirk; Honold, Konrad; Lorenz, Stefan
2016-01-01
By non-covalent association after proteolytic cleavage, the pro-domains modulate the activities of the mature growth factor domains across the transforming growth factor-β family. In the case of bone morphogenic protein 9 (BMP9), however, the pro-domains do not inhibit the bioactivity of the growth factor, and the BMP9·pro-domain complexes have equivalent biological activities as the BMP9 mature ligand dimers. By using real-time surface plasmon resonance, we could demonstrate that either binding of pro-domain-complexed BMP9 to type I receptor activin receptor-like kinase 1 (ALK1), type II receptors, co-receptor endoglin, or to mature BMP9 domain targeting antibodies leads to immediate and complete displacement of the pro-domains from the complex. Vice versa, pro-domain binding by an anti-pro-domain antibody results in release of the mature BMP9 growth factor. Based on these findings, we adjusted ELISA assays to measure the protein levels of different BMP9 variants. Although mature BMP9 and inactive precursor BMP9 protein were directly detectable by ELISA, BMP9·pro-domain complex could only be measured indirectly as dissociated fragments due to displacement of mature growth factor and pro-domains after antibody binding. Our studies provide a model in which BMP9 can be readily activated upon getting into contact with its receptors. This increases the understanding of the underlying biology of BMP9 activation and also provides guidance for ELISA development for the detection of circulating BMP9 variants. PMID:26677222
Collet-Brose, Justine
2016-01-01
The aim of this study was, at the assay development stage and thus with an appropriate degree of rigor, to select the most appropriate technology platform and sample pretreatment procedure for a clinical ADA assay. Thus, ELISA, MSD, Gyrolab, and AlphaLISA immunoassay platforms were evaluated in association with target depletion and acid dissociation sample pretreatment steps. An acid dissociation step successfully improved the drug tolerance for all 4 technology platforms and the required drug tolerance was achieved with the Gyrolab and MSD platforms. The target tolerance was shown to be better for the ELISA format, where an acid dissociation treatment step alone was sufficient to achieve the desired target tolerance. However, inclusion of a target depletion step in conjunction with the acid treatment raised the target tolerance to the desired level for all of the technologies. A higher sensitivity was observed for the MSD and Gyrolab assays and the ELISA, MSD, and Gyrolab all displayed acceptable interdonor variability. This study highlights the usefulness of evaluating the performance of different assay platforms at an early stage in the assay development process to aid in the selection of the best fit-for-purpose technology platform and sample pretreatment steps. PMID:27243038
Franklin, S.P.; Troyer, J.L.; TerWee, J.A.; Lyren, L.M.; Kays, R.W.; Riley, S.P.D.; Boyce, W.M.; Crooks, K.R.; VandeWoude, S.
2007-01-01
Although lentiviruses similar to feline immunodeficiency virus (FIV) are known to infect numerous felid species, the relative utility of assays used for detecting lentiviral infection has not been compared for many of these hosts. We tested bobcats (Lynx rufus), pumas (Felis concolor), and ocelots (Leopardus pardalis) for exposure to lentivirus using five different assays: puma lentivirus (PLV), African lion lentivirus (LLV), and domestic cat FIV-based immunoblots, a commercially available enzyme-linked immunosorbent assay (ELISA) kit, and nested polymerase chain reaction (PCR). Puma lentivirus immunoblots identified more seropositive individuals than the other antibody-detection assays. The commercial ELISA provided a fair ability to recognize seropositive samples when compared with PLV immunoblot for screening bobcats and ocelots, but not pumas. Polymerase chain reaction identified fewer positive samples than PLV immunoblot for all three species. Immunoblot results were equivalent whether the sample tested was serum, plasma, or whole blood. The results from this study and previous investigations suggest that the PLV immunoblot has the greatest ability to detect reactive samples when screening wild felids of North America and is unlikely to produce false positive results. However, the commercial ELISA kit may provide ap adequate alternative for screening of some species and is more easily adapted to field conditions. ?? Wildlife Disease Association 2007.
Identification of the antigenic region of Neospora caninum dense granule protein 7 using ELISA.
Abdelbaky, Hanan H; Fereig, Ragab M; Nishikawa, Yoshifumi
2018-06-26
Dense granule protein 7 (NcGRA7) is a potent diagnostic antigen of Neospora caninum. Some studies have reported on the difficult expression, low yield, and variable degree of solubility of recombinant NcGRA7. We aimed to unravel the possible causes for these issues and tested NcGRA7 antigenicity in enzyme linked immunosorbent assays (ELISAs). The NcGRA7 coding sequence (217 amino acids) was split into five amino acid regions: NcGRA7m (27-217), NcGRA7m3 (27-160), NcGRA7m4 (27-135), NcGRA7m5 (161-190), and NcGRA7m6 (188-217). Three fragments, NcGRA7m, NcGRA7m3 and NcGRA7m4, exhibited high antigenic properties when tested against experimentally-infected mice and dog sera by ELISA. High levels of IgG2 antibodies against NcGRA7m were observed in field dog sera. In experimentally and naturally-infected cattle, the N. caninum-specific sera only reacted with NcGRA7m, indicating that this antigenic region differs among the three animal species. This study presents valuable information about the antigenic properties and topology of NcGRA7, and highlights its suitability for diagnostic purposes. Copyright © 2018. Published by Elsevier B.V.
Kruse, Niels; Persson, Staffan; Alcolea, Daniel; Bahl, Justyna M C; Baldeiras, Ines; Capello, Elisabetta; Chiasserini, Davide; Bocchio Chiavetto, Luisella; Emersic, Andreja; Engelborghs, Sebastiaan; Eren, Erden; Fladby, Tormod; Frisoni, Giovanni; García-Ayllón, María-Salud; Genc, Sermin; Gkatzima, Olymbia; Heegaard, Niels H H; Janeiro, André M; Kováčech, Branislav; Kuiperij, H Bea; Leitão, Maria J; Lleó, Alberto; Martins, Madalena; Matos, Mafalda; Mollergard, Hanne M; Nobili, Flavio; Öhrfelt, Annika; Parnetti, Lucilla; de Oliveira, Catarina Resende; Rot, Uros; Sáez-Valero, Javier; Struyfs, Hanne; Tanassi, Julia T; Taylor, Peggy; Tsolaki, Magda; Vanmechelen, Eugeen; Verbeek, Marcel M; Zilka, Norbert; Blennow, Kaj; Zetterberg, Henrik; Mollenhauer, Brit
2015-09-01
Decreased levels of alpha-synuclein (aSyn) in cerebrospinal fluid (CSF) in Parkinson's disease and related synucleinopathies have been reported, however, not consistently in all cross-sectional studies. To test the performance of one recently released human-specific enzyme-linked immunosorbent assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program - Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings. Recommendations for further validation experiments and improvement of the interlaboratory results obtained are given. Copyright © 2015 Elsevier Inc. All rights reserved.
He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing
2018-06-01
Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3 ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.
Jutathis, Kamonthip; Kitisripanya, Tharita; Udomsin, Orain; Inyai, Chadathorn; Sritularak, Boonchoo; Tanaka, Hiroyuki; Putalun, Waraporn
2016-11-01
Genistein 7-O-[α-rhamnopyranosyl-(1→6)]-β-glucopyranoside (GTG) is a major bioactive compound in Derris scandens. It is responsible for anti-inflammatory activity by inhibition of cyclooxygenase and lipoxygenase. There are many commercial products of D. scandens available in Thailand. To develop an enzyme-linked immunosorbent assay (ELISA) for the quantitative analysis of GTG in plant material and derived products using a polyclonal antibody. An immunogen was synthesised by conjugating GTG with a carrier protein. The polyclonal antibody against GTG (GTG-PAb) was produced in New Zealand white rabbits. The ELISA method was validated for specificity, sensitivity, accuracy, precision and correlation with HPLC. The polyclonal antibody was specific to GTG and genistin within the range of compounds tested. The GTG ELISA was applied in the range 0.04-10.00 μg/mL with a limit of detection of 0.03 μg/mL. The recovery of GTG in spiked Derris scandens extracts ranged from 100.7 to 107.0%, with a coefficient of variation less than 7.0%. The intra- and inter-assay variations were less than 5.0%. The ELISA showed a good correlation with HPLC-UV analysis for GTG determination in samples, with a coefficient of determination (r 2 ) of 0.9880. An ELISA was established for GTG determination in Derris scandens. The GTG-PAb can react with GTG and genistin, but genistin has not been found in the plant. Therefore, the ELISA can be used for high throughput quality control of GTG content in D. scandens and its products. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Chen, S-C; Huang, F-M; Lee, S-S; Li, M-Z; Chang, Y-C
2009-04-01
To investigate the receptor activator of nuclear factor-kappa B (NF-kappaB) ligand (RANKL) in osteoblastic cells stimulated with inflammatory mediators. The expression of RANKL in human osteoblastic cell line U2OS stimulated by pro-inflammatory cytokine interleukin (IL)-1alpha and black-pigmented bacteria Porphyromonas endodontalis was investigated by Western blot and enzyme-linked immunosorbent assay (ELISA). The significance of the results obtained from control and treated groups was statistically analysed by the paired Student's t-test. IL-1alpha was found to upregulate RANKL production in U2OS cells (P < 0.05). Investigations of the time dependence of RANKL expression in IL-1alpha-treated cells revealed a rapid accumulation of RANKL protein after 1 h of exposure; it remained elevated throughout the 24-h incubation period shown by Western blot and ELISA. In addition, P. endodontalis also increased RANKL expression in U2OS cells after 4-h incubation period demonstrated by Western blot and ELISA (P < 0.05). IL-1alpha and P. endodontalis may be involved in developing apical periodontitis through the stimulation of RANKL production.
Dráberová, Eduarda; Stegurová, Lucie; Sulimenko, Vadym; Hájková, Zuzana; Dráber, Petr; Dráber, Pavel
2013-09-30
Microtubules formed by αβ-tubulin dimers represent cellular structures that are indispensable for the maintenance of cell morphology and for cell motility generation. Microtubules in intact cells are in highly regulated equilibrium with cellular pools of soluble tubulin dimers. Sensitive, reproducible and rapid assays are necessary to monitor tubulin changes in cytosolic pools after treatment with anti-mitotic drugs, during the cell cycle or activation and differentiation events. Here we describe new assays for α-tubulin quantification. The assays are based on sandwich ELISA, and the signal is amplified with biotinyl-tyramide or immuno-PCR. Matching monoclonal antibody pair recognizes phylogenetically highly conserved epitopes localized outside the C-terminal isotype-defining region. This makes it possible to detect α-tubulin isotypes in different cell types of various species. Biotinyl-tyramide amplification and immuno-PCR amplification enable detection of tubulin at concentrations 2.5ng/ml and 0.086ng/ml, respectively. Immuno-PCR detection shows enhanced sensitivity and wider dynamic range when compared to ELISA with biotinyl-tyramide detection. Our results on taxol-treated and activated bone marrow-derived mast cells demonstrate, that the assays allow sensitive quantification of tubulin in complex biological fluids. © 2013.
Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L
2017-09-01
C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision <11% and inter-assay precision <14%. PCP concentration measured by ELISA demonstrated a significant correlation with RIA (R 2 =.9721, P<.0001). This strong correlation supports use of the regression equation y=2.029x+0.0897 to transform ELISA data to RIA or inversely y=0.4930x-0.0456 to convert RIA data to ELISA for direct comparison between assays in the concentration range of 0-3.0 ng/mL. Measured C-peptide concentration was lower with the ELISA than with the RIA; individual measurements plotted against the averages of the pair demonstrated that the variability from the mean strongly depended on increasing concentration. Porcine C-peptide can be reliably measured in NHP serum using the Mercodia ELISA, making this assay interchangeable with the Millipore RIA. Inherent differences in antibody affinity and calibration factors may explain the lower ELISA values as compared to the RIA; however without access to a traceable reference standard, it is not possible to determine which assay is most accurate. Regression modeling resulted in a correction factor appropriate for conversion of ELISA data to RIA-equivalent data facilitating comparison of assay results longitudinally and between groups. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A monoclonal antibody based elisa for quantitation of human leukaemia inhibitory factor.
Taupin, J L; Gualde, N; Moreau, J F
1997-02-01
The authors report on the development of a new sandwich enzyme-linked immunoabsorbent assay (ELISA) for the quantitation of the human cytokine leukaemia inhibitory factor/human interleukin for DA cells (LIF/HILDA) with high accuracy and sensitivity (23 pg/ml), in less than 5 h and in various biological fluids. The antibodies used in this assay were raised against recombinant glycosylated LIF expressed in vivo following inoculation of recombinant vaccinia viruses, and screened with the biologically active cytokine in a flow cytometry assay using cells expressing a membrane-bound form of LIF. Furthermore, this home-made assay was compared with two commercially available ELISA kits. The results led to the conclusion that these three assays are far from being equivalent between each other, in terms of sensitivity towards non-glycosylated vs glycosylated LIF. Two major parameters must be incriminated: the glycosylation status of the LIF molecule used as the calibrator, and the binding characteristics of the monoclonal antibodies used to set up these assays toward LIF derived from Escherichia coli or from eukaryotic cells. This points out the importance of these parameters for the design of ELISAs meant for the quantitation of glycosylated cytokines in biological fluids.
ELISA, a demonstrator environment for information systems architecture design
NASA Technical Reports Server (NTRS)
Panem, Chantal
1994-01-01
This paper describes an approach of reusability of software engineering technology in the area of ground space system design. System engineers have lots of needs similar to software developers: sharing of a common data base, capitalization of knowledge, definition of a common design process, communication between different technical domains. Moreover system designers need to simulate dynamically their system as early as possible. Software development environments, methods and tools now become operational and widely used. Their architecture is based on a unique object base, a set of common management services and they host a family of tools for each life cycle activity. In late '92, CNES decided to develop a demonstrative software environment supporting some system activities. The design of ground space data processing systems was chosen as the application domain. ELISA (Integrated Software Environment for Architectures Specification) was specified as a 'demonstrator', i.e. a sufficient basis for demonstrations, evaluation and future operational enhancements. A process with three phases was implemented: system requirements definition, design of system architectures models, and selection of physical architectures. Each phase is composed of several activities that can be performed in parallel, with the provision of Commercial Off the Shelves Tools. ELISA has been delivered to CNES in January 94, currently used for demonstrations and evaluations on real projects (e.g. SPOT4 Satellite Control Center). It is on the way of new evolutions.
Long, Lin; Liu, Jianbo; Lu, Kaishun; Zhang, Tao; Xie, Yunqing; Ji, Yinglu; Wu, Xiaochun
2018-05-02
As a promising candidate for artificial enzymes, catalytically active nanomaterials show several advantages over natural enzymes, such as controlled synthesis at low cost, tunability of catalytic activities, and high stability under stringent conditions. Rod-shaped Au-Pt core/shell nanoparticles (Au@Pt NRs), prepared by Au nanorod-mediated growth, exhibit peroxidase-like activities and could serve as an inexpensive replacement for horseradish peroxidase, with potential applications in various bio-detections. The determination of measles virus is accomplished by a capture-enzyme-linked immunosorbent assay (ELISA) using Au@Pt NR-antigen conjugates. Based on the enhanced catalytic properties of this nanozyme probe, a linear response was observed up to 10 ng/mL measles IgM antibodies in human serum, which is 1000 times more sensitive than commercial ELISA. Hence, these findings provide positive proof of concept for the potential of Au@Pt NR-antigen conjugates in the development of colorimetric biosensors that are simple, robust, and cost-effective.
Seitz-Polski, Barbara; Dolla, Guillaume; Payré, Christine; Tomas, Nicola M; Lochouarn, Marine; Jeammet, Louise; Mariat, Christophe; Krummel, Thierry; Burtey, Stéphane; Courivaud, Cécile; Schlumberger, Wolfgang; Zorzi, Kévin; Benzaken, Sylvia; Bernard, Ghislaine; Esnault, Vincent L M; Lambeau, Gérard
2015-11-01
About 70% of patients with idiopathic membranous nephropathy (iMN) have autoantibodies to the phospholipase A2 receptor PLA2R1. We screened sera from iMN patients for their cross-reactivity to human (h), rabbit (rb) and mouse (m) PLA2R1 by western blot (WB) and antigen-specific ELISAs. All iMN patients recognized hPLA2R1 and rbPLA2R1 by WB, and a rbPLA2R1 ELISA was as sensitive as the standardized hPLA2R1 ELISA to monitor anti-PLA2R1 in patients with active disease or in drug-induced remission. In contrast, only 51% of patients were reactive to mPLA2R1 by WB, and a maximum of 78% were weakly to highly positive in the mPLA2R1 ELISA, suggesting that iMN patients exhibit different subsets of anti-PLA2R1 autoantibodies against epitopes that are shared or not among PLA2R1 orthologs. In a cohort of 41 patients with a mean follow-up of 42 months from anti-PLA2R1 assay, the detection of anti-mPLA2R1 autoantibodies was an independent predictor of clinical outcome in multivariate analysis (p = 0.009), and a ROC curve analysis identified a threshold of 605 RU/mL above which 100% of patients (12 patients) had a poor renal outcome (p < 0.001). A similar threshold could not be defined in hPLA2R1 and rbPLA2R1 ELISAs. We conclude that rbPLA2R1 is an alternative antigen to hPLA2R1 to measure anti-PLA2R1 in active disease while mPLA2R1 is a unique antigen that can detect a subset of anti-PLA2R1 autoantibodies present at high levels (>605 RU/mL) only in iMN patients at risk of poor prognosis, and is thus useful to predict iMN outcome. Copyright © 2015 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.
Rücker, Hannelore; Amslinger, Sabine
2015-01-01
The upregulation of heme oxygenase-1 (HO-1) has proven to be a useful tool for fighting inflammation. In order to identify new HO-1 inducers, an efficient screening method was developed which can provide new lead structures for drug research. We designed a simple ELISA-based HO-1 enzyme activity assay, which allows for the screening of 12 compounds in parallel in the setting of a 96-well plate. The well-established murine macrophage cell line RAW264.7 is used and only about 26µg of protein from whole cell lysates is needed for the analysis of HO-1 activity. The quantification of HO-1 activity is based on an indirect ELISA using the specific anti-bilirubin antibody 24G7 to quantify directly bilirubin in the whole cell lysate, applying a horseradish peroxidase-tagged antibody together with ortho-phenylenediamine and H2O2 for detection. The bilirubin is produced on the action of HO enzymes by converting their substrate heme to biliverdin and additional recombinant biliverdin reductase together with NADPH at pH 7.4 in buffer. This sensitive assay allows for the detection of 0.57-82pmol bilirubin per sample in whole cell lysates. Twenty-three small molecules, mainly natural products with an α,β-unsaturated carbonyl unit such as polyphenols, including flavonoids and chalcones, terpenes, an isothiocyanate, and the drug oltipraz were tested at typically 6 or 24h incubation with RAW264.7 cells. The activity of known HO-1 inducers was confirmed, while the chalcones cardamonin, flavokawain A, calythropsin, 2',3,4'-trihydroxy-4-methoxychalcone (THMC), and 2',4'-dihydroxy-3,4-dimethoxychalcone (DHDMC) were identified as new potent HO-1 inducers. The highest inductive power after 6h incubation was found at 10µM for DHDMC (6.1-fold), carnosol (3.9-fold), butein (3.1-fold), THMC (2.9-fold), and zerumbone (2.5-fold). Moreover, the time dependence of HO-1 protein production for DHDMC was compared to its enzyme activity, which was further evaluated in the presence of lipopolysaccharide and the specific HO-1 inhibitor tin protoporphyrin IX. Taken together, we developed a convenient and highly sensitive ELISA-based HO-1 enzyme activity assay, allowing the identification and characterization of molecules potentially useful for the treatment of inflammatory and autoimmune diseases. Copyright © 2014 Elsevier Inc. All rights reserved.
Enzyme-linked immunosorbent assay for diagnosis of Amphimerus spp. liver fluke infection in Humans
Cevallos, William; Calvopiña, Manuel; Nipáz, Victoria; Vicente-Santiago, Belén; López-Albán, Julio; Fernández-Soto, Pedro; Guevara, Ángel; Muro, Antonio
2017-01-01
BACKGROUND Amphimerus spp. is a liver fluke that infects humans and domestic animals. It is highly prevalent in some Ecuadorian communities. Currently, diagnosis is based on the microscopic observation of eggs in faeces, but this has variable sensitivity. More sensitive methods are needed for diagnostic testing. OBJECTIVE The main objective of this work was to develop an enzyme-linked immunosorbent assay (ELISA) using crude antigens from Amphimerus spp. adult worms to detect anti-Amphimerus IgG in human sera. METHODS Crude somatic antigens were obtained from adult Amphimerus spp. worms. Human sera from 119 patients were tested: 48 from individuals with a confirmed Amphimerus spp. infection, 78 from non-infected Ecuadorians living in the endemic region, 60 from persons living in non-endemic areas (20 Ecuadorians, 20 Europeans, and 20 Africans), and 33 who had other parasitic and non-parasitic infections. PRINCIPAL FINDINGS Results were analysed using the receiver-operator characteristic (ROC) curve analysis with an area under curve (AUC) value of 0.967. The accuracy of the ELISA was high. The sensitivity was 85.0% [95% confidence interval (CI): 80.3-89.7%] and the specificity was 71.0% (95% CI: 65.2-76.8%). Some cross reactivity was detected against Paragonimus mexicanus, Fasciola hepatica, Schistosomiasis, Taenia solium, Strongyloides stercoralis, Mansonella spp., and Vampirolepis nana. MAIN CONCLUSIONS We have developed the first ELISA technique that detects anti-Amphimerus IgG in human sera with good sensitivity, repeatability and reproducibility. However, more specific antigens are needed to further enhance performance of this assay. Regardless, this ELISA test could be useful for early diagnosis and prompt treatment of human Amphimerus spp. infections. PMID:28443982
Bano, Luca; Drigo, Ilenia; Tonon, Elena; Berto, Giacomo; Tavella, Alexander; Woudstra, Cedric; Capello, Katia; Agnoletti, Fabrizio
2015-12-01
Bovine botulism is a sporadic acute disease that usually causes catastrophic losses in the herds. The unusual clinical evolution of a persistent mild outbreak in a dairy herd, prompted us to characterize the neurotoxin gene profile of the strain involved and to evaluate whether seroconversion had occurred. Diagnosis was based on mild classical symptoms and was supported by PCR and bacteriological findings, which revealed the involvement of a non-mosaic type C strain. An in-house ELISA was developed to detect antibodies to botulinum neurotoxin type C and its performance was evaluated in a vaccination study. Fifty days after the index case, fecal and serum samples were collected from the 14 animals of the herd and screened for Clostridium botulinum and anti-botulinum neurotoxin antibodies type C, respectively. The in-house developed ELISA was also used to test 100 sera samples randomly collected from 20 herds. Strong ELISA reactions were observed in 3 convalescent and 5 asymptomatic animals involved in the studied outbreak. The ELISA-positive cows all tested positive for non-mosaic C. botulinum type C in the feces and the same strain was also detected in the alfalfa hay, suspected to be the carrier source. Ten out of the 100 randomly collected sera tested positive for anti-botulinum neurotoxin type C antibodies: 7 had borderline values and 3 from the same herd showed titers three times higher than the cut-off. We concluded that type C botulism in cattle may occur with variable severity and that prolonged exposure to sublethal doses of botulinum neurotoxin C may occur, resulting in detectable antibodies. Copyright © 2015 Elsevier Ltd. All rights reserved.
Prieto, José M; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E; Garrido, Joseba M; Juste, Ramon A; Alonso-Hearn, Marta
2014-08-01
The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Prieto, José M.; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E.; Garrido, Joseba M.; Juste, Ramon A.
2014-01-01
The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. PMID:24872517
Heida, Anke; Knol, Mariska; Kobold, Anneke Muller; Bootsman, Josette; Dijkstra, Gerard; van Rheenen, Patrick F
2017-11-01
An increasing number of physicians use repeated measurements of stool calprotectin to monitor intestinal inflammation in patients with inflammatory bowel diseases (IBDs). A lateral flow-based rapid test allows patients to measure their own stool calprotectin values at home. The test comes with a software application (IBDoc; Bühlmann Laboratories AG, Schönenbuch, Switzerland) that turns a smartphone camera into a results reader. We compared results from this method with those from the hospital-based reader (Quantum Blue; Bühlmann Laboratories AG) and enzyme-linked immunosorbent assay (ELISA) analysis. In a single-center comparison study, we asked 101 participants (10 years of age or older) in the Netherlands to perform the IBDoc measurement on stool samples collected at home, from June 2015 to October 2016. Participants then sent the residual extraction fluid and a fresh specimen from the same bowel movement to our pediatric and adult IBD center at the University Medical Center Groningen, where the level of calprotectin was measured by the Quantum Blue reader and ELISA analysis, respectively. The primary outcome was the agreement of results between IBDoc and the Quantum Blue and ELISA analyses, determined by Bland-Altman plot analysis. We received 152 IBDoc results, 138 samples of residual extraction fluid for Quantum Blue analysis, and 170 fresh stool samples for ELISA analysis. Spearman's rank correlation coefficient was 0.94 for results obtained by IBDoc vs Quantum Blue and 0.85 for results obtained by IBDoc vs ELISA. At the low range of calprotectin level (<500 μg/g), 91% of IBDoc-Quantum Blue results were within the predefined limits of agreement (±100 μg/g), and 71% of IBDoc-ELISA results were in agreement. At the high range of calprotectin level (≥500 μg/g), 81% of IBDoc-Quantum Blue results were within the predefined limits of agreement (±200 μg/g) and 64% of IBDoc-ELISA results were in agreement. Measurements of fecal levels of calprotectin made with home-based lateral flow method were in agreement with measurements made by Quantum Blue and ELISA, as long as concentrations were <500 μg/g. For patients with concentrations of fecal calprotectin above this level, findings from IBDoc should be confirmed by another method. (Netherlands Trial Registration Number: NTR5133). Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Akapirat, Siriwat; Avihingsanon, Anchalee; Ananworanich, Jintanat; Schuetz, Alexandra; Ramasoota, Pongrama; Luplertlop, Natthanej; Ono, Ken-Ichiro; Ikuta, Kazuyoshi; Utachee, Piraporn; Kameoka, Masanori; Leaungwutiwong, Pornsawan
2013-09-01
We conducted this study to determine the clinical variables associated with the production of human immunodeficiency virus type 1 (HIV-1) circulating recombinant form (CRF) 01_AE neutralizing human monoclonal antibodies (NhMAbs) using a hybridoma technique. This cross sectional study was performed in 20 asymptomatic HIV-1-infected Thais. Peripheral blood mononuclear cells (PBMCs) were obtained from each study participant and fused with SPYMEG cells. Culture supernatant collected from growing hybridomas was tested for neutralizing activity against HIV-1 CRF01_AE Env-recombinant viruses. Fifty hybridomas expressing anti-HIV-1 NhMAbs with strong neutralizing activity against at least 1 CRF01_AE Env-recombinant virus were found. A positive association between the numbers of hybridomas produced and the CD4 counts of study participants (p = 0.019) was observed. NhMAb-producing hybridomas with strong neutralizing activity were mostly found in participans diagnosed with HIV-1 infection within the previous 1 year. The HIV-1 viral load was not significantly correlated with the numbers of either established hybridomas or clones expressing anti-HIV-1 NhMAbs with strong neutralizing activity. To our knowledge, this is the first study of NhMAb-producing hybridomas obtained from HIV-1 CRF01_AE-infected populations identified by antibody binding to HIV-1 V3 loop peptide enzyme-linked immunosorbent assay (ELISA) or TRUGENE HIV-1 Genotyping Assay (HIV-1 pol sequence). It provides important criterion to slect study participants with high CD4 counts who produce large numbers of hybridoma clones. The results are valuable for further studies related to nurtalizing antibodies production and HIV-1 vaccine development.
Reyes-Beltrán, Benjamín; Delgado, Gabriela
2017-12-01
The present study was undertaken to detect antibodies against etanercept (ETN) in a group of Colombian patients with rheumatoid arthritis (RA) and being treated with Enbrel ® vs. Etanar ® . From these patients with RA, clinical and laboratory data were collected and serum taken for anti-drug antibody (ADAb) analysis. Samples from 32 patients (16 who had been treated with Enbrel ® and 16 with Etanar ® ) were analyzed. Positive sera for ADAb were found in six of the 32 subjects (18.7%); five (31.2%) in the Enbrel ® group and one (6.25%) in the Etanar ® group. Patients under treatment with Enbrel ® registered a longer disease duration than patients being treated with Etanar ® (15.4 years vs. 10.98 years, p = 0.175) as well as a longer average treatment with the drug (45.7 vs. 23.9 months, p = 0.052). The percentage of patients with disease activity defined as a disease activity score by C-reactive protein (DAS28-CRP) scores ≥2.3 was higher in those patients with positive sera in the enzyme-linked immunosorbent assay (ELISA) (66.7%) than in those with negative sera (34.6%). A logistic regression test revealed that the higher the DAS28-CRP value, the higher the ELISA absorbance value. The results showed evidence of greater frequency of ADAb in patients treated with ETN than has been reported to date. Greater disease activity was seen in those patients in whose serum ADAb had been detected. Significant differences were found between the positive ELISA for the group of patients treated with Enbrel ® compared to those treated with Etanar ® . Some of the factors that could explain this difference are the length of the treatment time with the drug, the commercial ELISA kit used to detect ADAb, or the immunogenicity itself of each product.
The nuclear-factor kappaB pathway is activated in pterygium.
Siak, Jay Jyh Kuen; Ng, See Liang; Seet, Li-Fong; Beuerman, Roger W; Tong, Louis
2011-01-05
Pterygium is a prevalent ocular surface disease with unknown pathogenesis. The authors investigated the role of nuclear factor kappa B (NF-κB) transcription factors in pterygium. Surgically excised primary pterygia were studied compared with uninvolved conjunctiva tissues. NF-κB activation was evaluated using Western blot analysis, ELISA, and DNA-binding assays. Primary pterygium fibroblasts were treated with TNF-α (20 ng/mL), and NF-κB activation was evaluated using immunocytochemistry, Western blot analysis, phospho-IκBα ELISA, and DNA-binding assays. TNF-α stimulation of NF-κB target genes RelB, NFKB2, RANTES, MCP-1, ENA-78, MMP-1, MMP-2, and MMP-3 in pterygium fibroblasts was compared with that in primary tenon fibroblasts by real-time PCR. Phosphorylation of IκBα (Ser32) was increased in pterygia tissues compared with uninvolved conjunctiva tissues, as determined by Western blot analysis and ELISA. IκBα expression was decreased, whereas nuclear RelA and p50 DNA-binding capacities were increased. Within 30 minutes of treatment with TNF-α, pterygium fibroblasts showed increased IκBα phosphorylation and nuclear translocation of RelA and p50. Treatment with TNF-α beyond 12 hours resulted in increased nuclear expression of RelB, p100, and p52. Furthermore, the upregulation of RANTES, MCP-1, ENA-78, MMP-1, MMP-2, and MMP-3 expression was more pronounced in TNF-α-treated pterygium fibroblasts than in tenon fibroblasts. The NF-κB pathway is shown for the first time to be activated in pterygia tissues compared with normal conjunctiva tissues. Stimulation by the inflammatory cytokine TNF-α can activate both canonical and noncanonical NF-κB pathways in pterygium fibroblasts with concomitant upregulation of NF-κB target genes.
2017-01-01
Tamm-Horsfall protein (THP) is an abundant urinary protein of renal origin. We hypothesize that THP can act as an inhibitor of complement since THP binds complement 1q (C1q) of the classical complement pathway, inhibits activation of this pathway, and is important in decreasing renal ischemia-reperfusion injury (a complement-mediated condition). In this study, we began to investigate whether THP interacted with the alternate complement pathway via complement factor H (CFH). THP was shown to bind CFH using ligand blots and in an ELISA (KD of 1 × 10−6 M). Next, the ability of THP to alter CFH’s normal action as it functioned as a cofactor in complement factor I (CFI)–mediated complement 3b (C3b) degradation was investigated. Unexpectedly, control experiments in these in vitro assays suggested that THP, without added CFH, could act as a cofactor in CFI-mediated C3b degradation. This cofactor activity was present equally in THP isolated from 10 different individuals. While an ELISA demonstrated small amounts of CFH contaminating THP samples, these CFH amounts were insufficient to explain the degree of cofactor activity present in THP. An ELISA demonstrated that THP directly bound C3b (KD ~ 5 × 10−8 m), a prerequisite for a protein acting as a C3b degradation cofactor. The cofactor activity of THP likely resides in the protein portion of THP since partially deglycosylated THP still retained cofactor activity. In conclusion, THP appears to participate directly in complement inactivation by its ability to act as a cofactor for C3b degradation, thus adding support to the hypothesis that THP might act as an endogenous urinary tract inhibitor of complement. PMID:28742158
ELISA-BASE: An Integrated Bioinformatics Tool for Analyzing and Tracking ELISA Microarray Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Amanda M.; Collett, James L.; Seurynck-Servoss, Shannon L.
ELISA-BASE is an open-source database for capturing, organizing and analyzing protein enzyme-linked immunosorbent assay (ELISA) microarray data. ELISA-BASE is an extension of the BioArray Soft-ware Environment (BASE) database system, which was developed for DNA microarrays. In order to make BASE suitable for protein microarray experiments, we developed several plugins for importing and analyzing quantitative ELISA microarray data. Most notably, our Protein Microarray Analysis Tool (ProMAT) for processing quantita-tive ELISA data is now available as a plugin to the database.
Lynch, Maria Isabel; Malagueño, Elizabeth; Lynch, Luiz Felipe; Ferreira, Silvana; Stheling, Raphael; Oréfice, Fernando
2009-09-01
Toxoplasma gondii causes posterior uveitis and the specific diagnosis is based on clinical criteria. The presence of anti-T. gondii secretory IgA (sIgA) antibodies in patients' tears has been reported and an association was found between ocular toxoplasmosis and the anti-T. gondii sIgA isotype in Brazilian patients. The purpose of this study was to provide an objective validation of the published ELISA test for determining the presence of anti-T. gondii sIgA in the tears of individuals with ocular toxoplasmosis. Tears from 156 patients with active posterior uveitis were analysed; 82 of them presented characteristics of ocular toxoplasmosis (standard lesion) and 74 patients presented uveitis due to other aetiologies. Cases of active posterior uveitis were considered standard when a new inflammatory focus satellite to old retinochoroidal scars was observed. The determination of anti-T. gondii sIgA was made using an ELISA test with crude tachyzoite antigenic extracts. Tears were collected without previous stimulation. Detection of sIgA showed 65.9% sensitivity (95% CI = 54.5-74.4), 71.6% specificity (95% CI = 59.8-81.2), a positive predictive value of 72% (95% CI = 60.3-81.5) and a negative predictive value of 65.4% (95% CI = 54.0-75.4). sIgA reactivity was higher in the tears of patients with active posterior uveitis due to T. gondii (p < 0.05). The test is useful for differentiating active posterior uveitis due to toxoplasmosis from uveitis caused by other diseases.
Ni, Y; Nesrallah, J; Agnew, M; Geske, F J; Favaloro, E J
2013-01-01
Introduction Laboratory diagnosis of von Willebrand disease (VWD) requires determination of both von Willebrand factor (VWF) protein levels and activity. Current VWF activity tests include the ristocetin cofactor assay and the collagen-binding assay (VWF:CB). The goal of this investigation is to characterize a new collagen-binding assay and to determine its effectiveness in identifying VWD. Methods Analytical studies were carried out to characterize the performance of a new VWF:CB ELISA. Additionally, samples from a normal population were tested as were well-characterized type 1 and type 2 VWD samples. Results Repeatability and within-laboratory precision studies resulted in coefficients of variation (CVs) of ≤11%. A linear range of 1–354% (0.01–3.54 IU/mL) was determined, along with a limit of detection and a lower limit of quantitation of 1.6% and 4.0% (0.016 and 0.04 IU/mL), respectively. Samples tested from apparently healthy individuals resulted in a normal range of 54–217% (0.54–2.17 IU/mL). Known VWD type 1 and type 2 samples were also analyzed by the ELISA, with 99% of samples having VWF:CB below the normal reference range and an estimated 96% sensitivity and 87% specificity using a VWF collagen-binding/antigen cutoff ratio of 0.50. Conclusion This new VWF:CB ELISA provides an accurate measure of collagen-binding activity that aids in the diagnosis and differentiation of type 1 from type 2 VWD. PMID:23107512
Shen, H D; Choo, K B; Chen, J H; Lin, W L; Chang, Z N; Han, S H
1992-04-01
A monoclonal antibody (MoAb P40) against the 68 kD major allergen of Penicillium notatum (P. notatum) was obtained by immunizing the mouse with a crude extract of P. notatum. Analysed by two-dimensional gel electrophoresis and immunoblotting, P40 reacted with two different isoforms of the 68 kD component of P. notatum with pIs of 5.4 and 5.5. In addition to P. notatum, P40 showed positive ELISA activity to Aspergillus fumigatus (A. fumigatus) but not to components of six other fungi including Alternaria porri, Cladosporium cladosporoides, Aureobasidium pullulans, Fusarium solani, Rhizopus arrhizus and Candida albicans. Analysed by ELISA, MoAb P40 also showed positive activity to two (P. frequentans and P. roseopurpureum) of the 10 other Penicillium species and two (A. terreus and A. flavus) of the four other Aspergillus species tested. SDS-PAGE and immunoblotting studies demonstrated P40 positive reactivity to components with MW of about 67 kD in all these Penicillium and Aspergillus species with positive ELISA activity to P40. Furthermore, immunoblotting activity of MoAb P40 to the 67 kD component of A. niger was also observed. The epitope of the 68 kD allergen of P. notatum recognized by MoAb P40 was resistant to treatment of periodate oxidation with concentration of NaIO4 up to 20 mM. This MoAb may thus be useful in the characterization and purification of the 68 kD allergen from crude extracts, and in the molecular cloning of allergen genes.
Enzyme-linked immunoassay for dengue virus IgM and IgG antibodies in serum and filter paper blood.
Tran, Thanh Nga T; de Vries, Peter J; Hoang, Lan Phuong; Phan, Giao T; Le, Hung Q; Tran, Binh Q; Vo, Chi Mai T; Nguyen, Nam V; Kager, Piet A; Nagelkerke, Nico; Groen, Jan
2006-01-25
The reproducibilty of dengue IgM and IgG ELISA was studied in serum and filter paper blood spots from Vietnamese febrile patients. 781 pairs of acute (t0) and convalescent sera, obtained after three weeks (t3) and 161 corresponding pairs of filter paper blood spots were tested with ELISA for dengue IgG and IgM. 74 serum pairs were tested again in another laboratory with similar methods, after a mean of 252 days. Cases were classified as no dengue (10 %), past dengue (55%) acute primary (7%) or secondary (28%) dengue. Significant differences between the two laboratories' results were found leading to different diagnostic classification (kappa 0.46, p < 0.001). Filter paper results correlated poorly to serum values, being more variable and lower with a mean (95% CI) difference of 0.82 (0.36 to 1.28) for IgMt3, 0.94 (0.51 to 1.37) for IgGt0 and 0.26 (-0.20 to 0.71) for IgGt3. This also led to differences in diagnostic classification (kappa value 0.44, p < 0.001) The duration of storage of frozen serum and dried filter papers, sealed in nylon bags in an air-conditioned room, had no significant effect on the ELISA results. Dengue virus IgG antibodies in serum and filter papers was not affected by duration of storage, but was subject to inter-laboratory variability. Dengue virus IgM antibodies measured in serum reconstituted from blood spots on filter papers were lower than in serum, in particular in the acute phase of disease. Therefore this method limits its value for diagnostic confirmation of individual patients with dengue virus infections. However the detection of dengue virus IgG antibodies eluted from filter paper can be used for sero-prevalence cross sectional studies.
Enzyme-linked immunoassay for dengue virus IgM and IgG antibodies in serum and filter paper blood
Tran, Thanh Nga T; de Vries, Peter J; Hoang, Lan Phuong; Phan, Giao T; Le, Hung Q; Tran, Binh Q; Vo, Chi Mai T; Nguyen, Nam V; Kager, Piet A; Nagelkerke, Nico; Groen, Jan
2006-01-01
Background The reproducibilty of dengue IgM and IgG ELISA was studied in serum and filter paper blood spots from Vietnamese febrile patients. Methods 781 pairs of acute (t0) and convalescent sera, obtained after three weeks (t3) and 161 corresponding pairs of filter paper blood spots were tested with ELISA for dengue IgG and IgM. 74 serum pairs were tested again in another laboratory with similar methods, after a mean of 252 days. Results Cases were classified as no dengue (10 %), past dengue (55%) acute primary (7%) or secondary (28%) dengue. Significant differences between the two laboratories' results were found leading to different diagnostic classification (kappa 0.46, p < 0.001). Filter paper results correlated poorly to serum values, being more variable and lower with a mean (95% CI) difference of 0.82 (0.36 to 1.28) for IgMt3, 0.94 (0.51 to 1.37) for IgGt0 and 0.26 (-0.20 to 0.71) for IgGt3. This also led to differences in diagnostic classification (kappa value 0.44, p < 0.001) The duration of storage of frozen serum and dried filter papers, sealed in nylon bags in an air-conditioned room, had no significant effect on the ELISA results. Conclusion Dengue virus IgG antibodies in serum and filter papers was not affected by duration of storage, but was subject to inter-laboratory variability. Dengue virus IgM antibodies measured in serum reconstituted from blood spots on filter papers were lower than in serum, in particular in the acute phase of disease. Therefore this method limits its value for diagnostic confirmation of individual patients with dengue virus infections. However the detection of dengue virus IgG antibodies eluted from filter paper can be used for sero-prevalence cross sectional studies. PMID:16436203
Yang, Tao; Yang, Lijun; Chai, Weiran; Li, Renke; Xie, Jun; Niu, Bo
2011-03-01
A phage display single-chain variable fragment (scFv) library against TNFα was constructed using a recombinant phage antibody system (RPAS). The cloned scFv gene was introduced into the phage display vector pCANTAB 5E and expressed in Escherichia coli (E. coli) with a yield of up to 0.15 mg/l of total protein. With the attempt to improve the expression level of TNF-scFv, a strategy was established for subcloning the scFv gene from pCANTAB 5E into the plasmid pBV220. Under the control of a highly efficient tandem P(R)P(L) promoter system, scFv production was increased to 30% of total protein as inclusion bodies. After extraction from the cell pellet by sonication, the inclusion bodies were solubilized and denatured in the presence of 8M urea. Purification of denatured scFv was performed using nickel column chromatography followed by renaturation. The purity and activity of the refolded scFv were confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), Western blotting and by an enzyme-linked immunoabsorbent assay (ELISA). The results reveal that the overall yield of bioactive TNF-scFv from E. coli flask cultures was more than 45 mg/l culture medium and 15 mg/g wet weight cells. The renatured scFv exhibited binding activity similarly to soluble scFv. In conclusion we developed a method to over-express TNF-scFv, which have biological function after purification and renaturation. Copyright © 2010 Elsevier Inc. All rights reserved.
Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar
2012-11-26
HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.
2012-01-01
Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful. PMID:23181517
Enzyme-linked immunosorbent assays for Z-DNA.
Thomas, M J; Strobl, J S
1988-10-01
Dot blot and transblot enzyme-linked immunosorbent assays (e.l.i.s.a.) are described which provide sensitive non-radioactive methods for screening Z-DNA-specific antisera and for detecting Z-DNA in polydeoxyribonucleotides and supercoiled plasmids. In the alkaline phosphatase dot blot e.l.i.s.a., Z-DNA, Br-poly(dG-dC).poly(dG-dC), or B-DNA, poly(dG-dC).poly(dG-dC), poly(dA-dT).poly(dA-dT), Br-poly(dI-dC).poly(dI-dC), or salmon sperm DNA were spotted onto nitrocellulose discs and baked. The e.l.i.s.a. was conducted in 48-well culture dishes at 37 degrees C using a rabbit polyclonal antiserum developed against Br-poly(dG-dC).poly(dG-dC), an alkaline phosphatase-conjugated second antibody, and p-nitrophenol as the substrate. Under conditions where antibody concentrations were not limiting, alkaline phosphatase activity was linear for 2 h. Dot blot e.l.i.s.a. conditions are described which allow quantification of Z-DNA [Br-poly(dG-dC).poly(dG-dC)] within the range 5-250 ng. Dot blot and transblot horseradish peroxidase e.l.i.s.a. are described that detect Z-DNA within supercoiled plasmid DNAs immobilized on diazophenylthioether (DPT) paper. In the transblot e.l.i.s.a., plasmid pUC8 derivatives containing 16, 24, or 32 residues of Z-DNA were electrophoresed in agarose gels and electrophoretically transferred to DPT paper. Z-DNA-antibody complexes were detected by the horseradish peroxidase-catalysed conversion of 4-chloro-1-naphthol to a coloured product that was covalently bound to the DPT paper. Z-DNA antibody reactivity was specific for supercoiled Z-DNA containing plasmids after removal of the antibodies cross-reactive with B-DNA by absorption onto native DNA-cellulose. The transblot e.l.i.s.a. was sensitive enough to detect 16 base pairs of alternating G-C residues in 100 ng of pUC8 DNA.
2012-01-01
Background Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA. PMID:23259607
Du, Yanfen; Qi, Yingfang; Yu, Lu; Lin, Jingkai; Liu, Siguo; Ni, Hongbo; Pang, Hai; Liu, Huifang; Si, Wei; Zhao, Hailing; Wang, Chunlai
2011-06-01
We studied throat swabs and corresponding serum samples collected from 1067 protein purified derivative (PPD)-tuberculin skin test (TST) positive cattle from different regions of China. The 1067 throat swabs were inoculated onto modified Löwenstein-Jensen medium for the isolation and culture of Mycobacteria. Acid-fast bacilli were identified using traditional biochemical methods, polymerase chain reaction (PCR) amplification and multiplex PCR. They were distinguished as Mycobacterium tuberculosis complex (MTBC) and non-tuberculous mycobacteria (NTM) strains. An indirect Enzyme-Linked Immunosorbent Assay (ELISA) was applied to detect specific antibodies against bovine TB (bTB). Correlations among the ELISA, bacteriology and TST were analyzed and compared. Spoligotyping and variable number tandem repeats-mycobacterial interspersed repetitive unit (VNTR-MIRU) analysis were used to genotype the MTBC. In total, 111 strains of Mycobacteria were cultured from the 1067 throat swab samples, including 43 stains of MTBC (14 strains of Mycobacterium bovis and 29 of Mycobacterium tuberculosis) and 68 strains of NTM. Thirty-eight MTBC strains and four NTM strains were isolated from 72 throat swab samples that the ELISA determined were antibody positive; five MTBC strains and 64 NTM strains were isolated from 995 throat swab samples that were antibody negative on the ELISA. The positive isolation rates of MTBC and NTM were 38.7% (43/111) and 61.3% (68/111), respectively. The concordance rate of cultured MTBC with a positive result on the indirect ELISA for antibody was 52.8% (38/72), which was much higher than the positive rate for TST (4.0%; 43/1067). Genotyping of the 43 strains of MTBC isolated, using spoligotyping and VNTR-MIRU, showed that the 43 isolates had 26 genotypes; 16 strains had a unique genotype. Two groups of six strains and two strains, respectively, showed the same spoligotyping pattern, and belonged to the Beijing family and Beijing-like family, respectively. Combined application of spoligotyping and VNTR-MIRU typing would improve the molecular epidemiological investigation and monitoring of the etiology of bTB in China. Copyright © 2010 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daly, Don S.; Anderson, Kevin K.; White, Amanda M.
Background: A microarray of enzyme-linked immunosorbent assays, or ELISA microarray, predicts simultaneously the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Making sound biological inferences as well as improving the ELISA microarray process require require both concentration predictions and creditable estimates of their errors. Methods: We present a statistical method based on monotonic spline statistical models, penalized constrained least squares fitting (PCLS) and Monte Carlo simulation (MC) to predict concentrations and estimate prediction errors in ELISA microarray. PCLS restrains the flexible spline to a fit of assay intensitymore » that is a monotone function of protein concentration. With MC, both modeling and measurement errors are combined to estimate prediction error. The spline/PCLS/MC method is compared to a common method using simulated and real ELISA microarray data sets. Results: In contrast to the rigid logistic model, the flexible spline model gave credible fits in almost all test cases including troublesome cases with left and/or right censoring, or other asymmetries. For the real data sets, 61% of the spline predictions were more accurate than their comparable logistic predictions; especially the spline predictions at the extremes of the prediction curve. The relative errors of 50% of comparable spline and logistic predictions differed by less than 20%. Monte Carlo simulation rendered acceptable asymmetric prediction intervals for both spline and logistic models while propagation of error produced symmetric intervals that diverged unrealistically as the standard curves approached horizontal asymptotes. Conclusions: The spline/PCLS/MC method is a flexible, robust alternative to a logistic/NLS/propagation-of-error method to reliably predict protein concentrations and estimate their errors. The spline method simplifies model selection and fitting, and reliably estimates believable prediction errors. For the 50% of the real data sets fit well by both methods, spline and logistic predictions are practically indistinguishable, varying in accuracy by less than 15%. The spline method may be useful when automated prediction across simultaneous assays of numerous proteins must be applied routinely with minimal user intervention.« less
Abrantes-Lemos, Clarice Pires; Nakhle, Maria Cristina; Damiao, Aderson Omar Mourao Cintra; Sipahi, Aytan Miranda; Carrilho, Flair José; Cancado, Eduardo Luiz R
2010-01-01
Sensitivity and specificity of anti-human tissue transglutaminase antibodies (anti-htTGA) seem to be superior to those of anti-tissue transglutaminase of guinea pig (anti-gptTGA) for screening patients with celiac disease (CD), but there are still controversies. The aim of this study was to evaluate the performance of two INOVA ELISA kits to detect IgA anti-htTGA and anti-gptTGA in patients with and without CD. The study groups were comprised of 49 anti-endomysial antibody (EMA)-positive untreated-CD, and 123 controls (EMA-negative treated CD, EMA-negative chronic diarrhea, autoimmune hepatitis, inflammatory bowel disease and healthy people). The agreement between the two ELISAs was statistically significant in all study groups and there was no significant difference between them (92.7% agreement; kappa = 0.70; kappa p = 0.001; McNemar p = 1). All patients with serum reactivity of more than 100 units had histologic diagnosis of CD. In seven of 10 patients with treated-CD who had control biopsies, villous atrophy was still present in four who tested positive by both kits. Two of three celiacs with histologic remission tested positive for both anti-tTGA. the anti-gptTGA and anti-htTGA determination were equally efficient in identifying patients with untreated-CD with high titers of EMA. Whatever the anti-tTGA ELISA used, the reactivity above 100 units was always related to active CD diagnosed by histologic alterations in intestinal biopsies. The anti-tTGA reactivity by both kits was not only similar in determining histologic activity in the follow-up of CD after a gluten free diet, but also in identifying positive sera from the control groups, regardless if CD has been confirmed by duodenal biopsies.
Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah
2018-01-01
Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
Clinical usefulness of Western blotting and ELISA avidity for the diagnosis of human toxocariasis.
Rudzińska, M; Kowalewska, B; Sikorska, K
2017-01-01
The serodiagnosis of human toxocariasis is difficult. Specific IgGs detected routinely with ELISA based on Toxocara excretory-secretory (TES) antigens often persist for years at an elevated level, which does not allow either the differentiation between an active and persistent infection or monitoring of the effect of treatment. Additionally, false-positive results may occur in co-infections with other helminths due to cross-reactions. We evaluated the usefulness of an IgG avidity index (AI) and a Western blotting (WB) IgG in the diagnosis of patients suspected of Toxocara infection. We studied 138 subjects who were submitted to serological testing two or more times. Confirmation of an infection by WB was achieved in 73.2% of patients. A high AI was obtained in 89.1% of patients, and low AI and borderline AI were found in only 10.9%. Low and borderline values of AI remained at similar levels in subsequent studies over 2-3 years. The results showed the necessity of obligatory verification of all ELISA IgG positive and questionable results by WB. The index of IgG avidity may be helpful in excluding recent infection, but its usefulness in detecting an active phase of invasion requires further research. © 2016 John Wiley & Sons Ltd.
Harmsen, T; Jongerius, M C; van der Zwan, C W; Plantinga, A D; Kraaijeveld, C A; Berbers, G A
1992-01-01
A 50% neutralization enzyme immunoassay (N50-EIA) was compared with an indirect enzyme-linked immunosorbent assay (ELISA) for determining mumps virus antibodies in three consecutive serum samples from 138 children vaccinated with a live mumps vaccine at the age (in years) of 1.5. By the N50-EIA, most (132 of 138) preserum samples did not show neutralizing activity. Eight to 12 weeks after vaccination, 17 of the children were still negative, but only 7 remained so after 2.5 years, resulting in a seroconversion rate of 125 of 132 (95%). Over the same period, the neutralization geometric mean titer rose from 3.6 to 9.9. By an indirect ELISA, 128 of 138 preserum samples were found negative. The early and late postvaccination sera of 8 children were ELISA negative, resulting in a seroconversion rate of 120 of 128 (94%). Only two children remained seronegative by both methods. Seven of the late postvaccination serum samples yielded noncorresponding results, reflecting 95% correlation between both methods. Due to cross-reactivity with parainfluenza viruses, the ELISA proved to be less specific, but on the other hand, it showed a greater sensitivity than the N50-EIA. PMID:1500523
Schmitz, Audrey; Le Bras, Marie-Odile; Guillemoto, Carole; Pierre, Isabelle; Rose, Nicolas; Bougeard, Stéphanie; Jestin, Véronique
2013-10-01
Following the emergence of highly pathogenic avian influenza (AI), active surveillance of infections due to the H5 and H7 subtypes in poultry has increased and been made compulsory in Europe since 2002, by means of annual serological surveys using the haemagglutination inhibition (HI) test. Domestic anseriforms, particularly ducks and geese, are more frequently infected by H5 low pathogenic AI virus, often subclinically, and represent a threat for other terrestrial poultry. 1783 sera, mainly from ducks, have been used to evaluate and compare a commercial ELISA kit detecting H5 antibodies with the currently recommended HI test. Different approaches to calculating specificity and sensitivity have been used, including the original Bayesian method. Results were similar when data were analyzed at the individual and batch levels, and when using different methods of calculation. However, results showed that H5 ELISA had both a higher sensitivity and a lower specificity than the HI test. Given that sensitivity is the most important factor for a screening test, H5 ELISA could therefore be recommended for AI surveillance, followed in cases of positivity by molecular tests aimed at detecting the virus gene. Copyright © 2013 Elsevier B.V. All rights reserved.
Development of monoclonal antibody-based sandwich ELISA for detection of dextran.
Wang, Sheng-Yu; Li, Zhe; Wang, Xian-Jiang; Lv, Sha; Yang, Yun; Zeng, Lian-Qiang; Luo, Fang-Hong; Yan, Jiang-Hua; Liang, Da-Feng
2014-10-01
Dextran as anti-nutritional factor is usually a result of bacteria activity and has associated serial problems during the process stream in the sugar industry and in medical therapy. A sensitive method is expected to detect dextran quantitatively. Here we generated four monoclonal antibodies (MAbs) against dextran using dextran T40 conjugated with bovine serum albumin (BSA) as immunogen in our lab following hybridoma protocol. Through pairwise, an MAb named D24 was determined to be conjugated with horseradish peroxidase (HRP) and was used in the establishment of a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) method for determination of dextran, in which MAb D9 was chosen as a capture antibody. The detection limit and working scope of the developed sandwich ELISA method were 3.9 ng/mL and 7.8-500 ng/mL with a correlation coefficient of 0.9909. In addition, the cross-reaction assay demonstrated that the method possessed high specificity with no significant cross-reaction with dextran-related substances, and the recovery rate ranged from 96.35 to 102.00%, with coefficient of variation ranging from 1.58 to 6.94%. These results indicated that we developed a detection system of MAb-based sandwich ELISA to measure dextran and this system should be a potential tool to determine dextran levels.
Teimouri, Aref; Modarressi, Mohammad Hossein; Shojaee, Saeedeh; Mohebali, Mehdi; Zouei, Nima; Rezaian, Mostafa; Keshavarz, Hossein
2018-05-08
In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera were tested to detect anti-toxoplasma IgG using Dynex DS2® and Roche Cobas® e411 Automated Analyzers. Discordant results rechecked using immunofluorescence assay (IFA). Then, sera were used in an in house Dot-ELISA to assess toxoplasma-specific IgG. Of the 219 samples, two samples were found undetermined using ECLIA but reactive using ELISA. Using IFA, the two sera were reported unreactive. Furthermore, two samples were found reactive using ECLIA and unreactive using ELISA. These samples were reported reactive using IFA. The overall agreement for the two former methods was 98% (rZ0.98.1; P < 0.001). The intrinsic parameters calculated for in house Dot-ELISA included sensitivity of 79.5, specificity of 78.2, and accuracy of 78.9%, compared to ECLIA and ELISA. Positive and negative predictive values included 82.9 and 74.2%, respectively. A 100% sensitivity was found in in house Dot-ELISA for highly reactive sera in ECLIA and ELISA. ECLIA is appropriate for the first-line serological screening tests and can replace ELISA due to high speed, sensitivity, and specificity, particularly in large laboratories. Dot-ELISA is a rapid, sensitive, specific, cost-effective, user-friendly, and field-portable technique and hence can be used for screening toxoplasmosis, especially in rural fields or less equipped laboratories.
Wang, Jiao; Song, Jingjing; Zhou, Shuimei; Fu, Yourong; Bailey, Jeffrey A; Shen, Changxin
2018-01-16
Identification of RhD antigen epitopes is a key component in understanding the pathogenesis of haemolytic disease of the foetus and newborn. Research has indicated that phage display libraries are useful tools for identifying novel mimic epitopes (mimotopes) which may help to determine antigen specificity. We selected the mimotopes of blood group RhD antigen by affinity panning a phage display library using monoclonal anti-D. After three rounds of biopanning, positive phage clones were identified by enzyme-linked immunosorbent assay (ELISA) and then sent for sequencing and peptides synthesis. Next, competitive ELISA and erythrocyte haemagglutination inhibition tests were carried out to confirm the inhibitory activity of the synthetic peptide. To evaluate the diagnostic performance of the synthetic peptide, a diagnostic ELISA was examined. Fourteen of 35 phage clones that were chosen randomly from the titering plate were considered to be positive. Following DNA sequencing and translation, 11 phage clones were found to represent the same peptide - RMKMLMMLMRRK (P4) - whereas each of the other three clones represented a unique peptide. Through the competitive ELISA and erythrocyte haemagglutination inhibition tests, the peptide (P4) was verified to have the ability to mimic the RhD antigen. The diagnostic ELISA for P4 proved to be sensitive (82.61%) and specific (88.57%). This study reveals that the P4 peptide can mimic RhD antigen and paves the way for the development of promising targeted diagnostic and therapeutic platforms for haemolytic disease of the foetus and newborn.
Pandre, Manoj Kumar; Shaik, Shama; Satya Pratap, Veera Venkata Valluri; Yadlapalli, Prasad; Yanamandra, Mahesh; Mitra, Sayan
2018-03-15
Tropomyosin-related kinase A (TRKA) fusion was originally detected in colorectal carcinoma that had resulted in expression of the oncogenic chimeric protein TPM3-TRKA. Lately, many more rearrangements in TRK family of kinases generating oncogenic fusion proteins have been identified. These genetic rearrangements usually result in fusion of cytoplasmic kinase domain of TRK to another gene of interest resulting in constitutive kinase activity. Estimation of TRK inhibitor potency in a cellular context is required for drug discovery programs and is measured by receptor phosphorylation levels upon compound administration. However, since a large chunk of the TRK protein is lost in this rearrangement, it's difficult to set up sandwich ELISA for detection of receptor phosphorylation in any cell assay harboring these fusion proteins. In order to address this issue, we developed a novel and robust in-cell ELISA method which quantifies the phosphorylation of TRK kinase (Tyr 674/675) within the KM12 cells. This cell based method is more versatile & economical than conventional ELISA using engineered overexpressing cell line and/or western blot methods. Performance reliability & robustness for the validated assay were determined by %CV and Z factor in assays with reference molecule larotrectinib. This in-cell ELISA method can be used with any TRKA rearranged oncogenic fusion cell type and can be extended to other TRK isoforms as well. We have used this assay to screen novel molecules in KM12 cells and to study pharmacodynamic properties of compounds in TRKA signaling. Copyright © 2018 Elsevier Inc. All rights reserved.
Villa-Mancera, Abel; Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José
2016-01-01
The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans.
Molina-Mendoza, Pedro; Hernández-Guzmán, Karina; Olivares-Pérez, Jaime; Sarracent-Pérez, Jorge; Zumaquero-Ríos, José
2016-01-01
The objective of present study was to determine the prevalence of natural caprine fasciolosis in the Mixteca region of Mexico using coproantigen and serum IgG1 ELISA tests for comparative purposes. A total of 1070 serum and faecal samples were analyzed for IgG1 antibodies and coproantigens, using ELISA with E/S products as antigen and a monoclonal antibody-based sandwich ELISA. Prevalence of 73.46% was found using the serological ELISA and a percentage of 77.20 was found for coproantigen ELISA. The diagnostic sensitivity and specificity for serum ELISA were 86.7% and 96.4%, and for the coproantigen ELISA they were 93.1% and 97.8%, respectively. The seropositive samples were further categorized as low, medium, or high positivity. Results show a great proportion of low and medium positive goats when the serum ELISA test was used. Correlation coefficients between coproantigens and seropositivity were statistically significant (P < 0.01) for low seropositivity (r = 0.93) and medium seropositivity (r = 0.84). The accuracy of faecal antigen ELISA was higher compared to indirect ELISA serological test. Two ELISAs were shown to be useful for demonstrating the current status of F. hepatica infection in the endemic areas and can be employed in studies on epidemiology as well as anthelmintics treatment for preventing economic loss and the risk of transmission to humans. PMID:27563665
Masson, Gustavo S; Nair, Anand R; Dange, Rahul B; Silva-Soares, Pedro Paulo; Michelini, Lisete C; Francis, Joseph
2015-01-01
Toll-like receptor 4 (TLR4) signaling induces tissue pro-inflammatory cytokine release and endoplasmic reticulum (ER) stress. We examined the role of TLR4 in autonomic dysfunction and the contribution of ER stress. Our study included animals divided in 6 experimental groups: rats treated with saline (i.v., 0.9%), LPS (i.v., 10mg/kg), VIPER (i.v., 0.1 mg/kg), or 4-PBA (i.p., 10 mg/kg). Two other groups were pretreated either with VIPER (TLR4 viral inhibitory peptide) LPS + VIPER (i.v., 0.1 mg/kg) or 4-Phenyl butyric acid (4-PBA) LPS + PBA (i.p., 10 mg/kg). Arterial pressure (AP) and heart rate (HR) were measured in conscious Sprague-Dawley rats. AP, HR variability, as well as baroreflex sensitivity (BrS), was determined after LPS or saline treatment for 2 hours. Immunofluorescence staining for NeuN, Ib1a, TLR4 and GRP78 in the hypothalamic paraventricular nucleus (PVN) was performed. TNF-α, TLR4 and GRP78 protein expression in the PVN were evaluated by western blot. Plasma norepinephrine levels were determined by ELISA. Acute LPS treatment increased HR and plasma norepinephrine concentration. It also decreased HR variability and high frequency (HF) components of HR variability, as well BrS. Acute LPS treatment increased TLR4 and TNF-α protein expression in the PVN. These hemodynamic and molecular effects were partially abrogated with TLR4 blocker or ER stress inhibitor pretreatment. In addition, immunofluorescence study showed that TLR4 is co-localized with GRP78in the neurons. Further inhibition of TLR4 or ER stress was able to attenuate the LPS-induced microglia activation. TLR4 signaling promotes autonomic dysfunction, inflammation and microglia activation, through neuronal ER stress, in the PVN.
Yusakul, Gorawit; Nuntawong, Poomraphie; Sakamoto, Seiichi; Ratnatilaka Na Bhuket, Pahweenvaj; Kohno, Toshitaka; Kikkawa, Nao; Rojsitthisak, Pornchai; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi
2017-01-01
Due to the highly specific binding between an antibody and its target, superior analytical performances was obtained by immunoassays for phytochemical analysis over conventional chromatographic techniques. Here, we describe a simple method for producing a functional single-chain variable fragment (scFv) antibody against ganoderic acid A (GAA), a pharmacologically active metabolite from Ganoderma lingzhi. The Escherichia coli BL21(DE3) strain produced a large amount of anti-GAA scFv. However, in vitro refolding steps, which partially recovered the reactivity of the scFv, were required. Interestingly, the functional scFv was expressed as a soluble and active form in the cytoplasm of an engineered E. coli SHuffle ® strain. Purified anti-GAA scFv, which yielded 2.56 mg from 1 L of culture medium, was obtained from simple and inexpensive procedures for expression and purification. The anti-GAA scFv-based indirect competitive enzyme-linked immunosorbent assay (icELISA) exhibited high sensitivity (linearity: 0.078-1.25 µg/mL) with precision (CV: ≤6.20%) and reliability (recovery: 100.1-101.8%) for GAA determination. In summary, the approach described here is an inexpensive, simple, and efficient expression system that extends the application of anti-GAA scFv-based immunoassays. In addition, when in vitro refolding steps can be skipped, the cost and complexity of scFv antibody production can be minimized.
George, Sergio; Mamani, Nora; Lucero, Yalda; Torres, Juan Pablo; Farfán, Mauricio; Lagomarcino, Anne J; Orellana, Andrea; O'Ryan, Miguel
2016-12-01
We previously detected Helicobacter pylori infection by stool antigen ELISA assay in 33-41% of asymptomatic Chilean children between 2-3 years of age, of which 11-20% had a transient infection and 21-22% a persistent infection. A total of 88% of ELISA-positive samples were also rtPCR positive, while 37/133 (33%) of ELISA-negative stool samples were rtPCR positive. The significance of a ELISA-negative/rtPCR-positive sample requires clarification. We aimed to determine whether rtPCR is able to detect persistent infections not detected by ELISA. We selected 36 children with an ELISA-negative/rtPCR-positive stool sample, of which 25 were never H. pylori infected according to ELISA, and 11 had a transient infection with an ELISA-positive sample before or after the discordant sample. At least two additional consecutive ELISA-negative samples per child were tested in duplicate by rtPCR for the 16s rRNA gene. A total of 14 of 78 (17.9%) rtPCR reactions were positive, but only 4/78 (5.1%) were positive in both duplicates, representing a total of 3/36 (8.3%) children with an additional rtPCR-positive sample, only one of whom was persistently negative by ELISA. One child with a transient infection had two positive rtPCR reactions despite negative ELISA samples. In H. pylori noninfected or transiently infected children, as determined by stool ELISA, additional ELISA-negative/rtPCR-positive stool samples were found in 8.3% of children, but a possible persistent infection was only identified in 2.7% of children. Thus, the characterization of infection dynamics in children is not being misrepresented by application of stool ELISA. Furthermore, rtPCR does not significantly improve dynamic characterization. © 2016 John Wiley & Sons Ltd.
Detection of Legionella pneumophila by PCR-ELISA method in industrial cooling tower water.
Soheili, Majid; Nejadmoghaddam, Mohammad Reza; Babashamsi, Mohammad; Ghasemi, Jamileh; Jeddi Tehrani, Mahmood
2007-11-15
Water supply and Cooling Tower Water (CTW) are among the most common sources of Legionella pneumophila (LP) contamination. A nonradio active method is described to detect LP in industrial CTW samples. DNA was purified and amplified by nested -PCR with amplimers specific for the 16s rRNA gene of LP. The 5' end biotinylated oligomer probe was immobilized on sterptavidin B coated microtiter plates. The nested-PCR product was labeled with digoxigenin and then hybridized with 5'-biotinylated probes. The amplification products were detected by using proxidase-labled anti dioxygenin antibody in a colorimetric reaction. The assay detected LP present in 1 L of 5 CTW samples examined. All of the samples were Legionella positive in both culture and PCR-ELISA methods. The PCR-ELISA assay appears to exhibit high specificity and is a more rapid technique in comparison with bacterial culture method. Thus could prove suitable for use in the routine examination of industrial CTW contamination.
Tamarozzi, Francesca; Covini, Ilaria; Mariconti, Mara; Narra, Roberta; Tinelli, Carmine; De Silvestri, Annalisa; Manzoni, Federica; Casulli, Adriano; Ito, Akira; Neumayr, Andreas; Brunetti, Enrico
2016-01-01
Background The diagnosis of cystic echinococcosis (CE) is based primarily on imaging, in particular with ultrasound for abdominal CE, complemented by serology when imaging results are unclear. In rural endemic areas, where expertise in ultrasound may be scant and conventional serology techniques are unavailable due to lack of laboratory equipment, Rapid Diagnostic Tests (RDTs) are appealing. Methodology/Principal Findings We evaluated the diagnostic accuracy of 3 commercial RDTs for the diagnosis of hepatic CE. Sera from 59 patients with single hepatic CE cysts in well-defined ultrasound stages (gold standard) and 25 patients with non-parasitic cysts were analyzed by RDTs VIRapid HYDATIDOSIS (Vircell, Spain), Echinococcus DIGFA (Unibiotest, China), ADAMU-CE (ICST, Japan), and by RIDASCREEN Echinococcus IgG ELISA (R-Biopharm, Germany). Sensitivity, specificity and ROC curves were compared with McNemar and t-test. For VIRapid and DIGFA, correlation between semiquantitative results and ELISA OD values were evaluated by Spearman’s coefficient. Reproducibility was assessed on 16 randomly selected sera with Cohen’s Kappa coefficient. Sensitivity and Specificity of VIRapid (74%, 96%) and ADAMU-CE (57%, 100%) did not differ from ELISA (69%, 96%) while DIGFA (72%, 72%) did (p = 0.045). ADAMU-CE was significantly less sensitive in the diagnosis of active cysts (p = 0.019) while DIGFA was significantly less specific (p = 0.014) compared to ELISA. All tests were poorly sensitive in diagnosing inactive cysts (33.3% ELISA and ADAMU-CE, 42.8% DIGFA, 47.6% VIRapid). The reproducibility of all RDTs was good-very good. Band intensity of VIRapid and DIGFA correlated with ELISA OD values (r = 0.76 and r = 0.79 respectively, p<0.001). Conclusions/Significance RDTs may be useful in resource-poor settings to complement ultrasound diagnosis of CE in uncertain cases. VIRapid test appears to perform best among the examined kits, but all tests are poorly sensitive in the presence of inactive cysts, which may pose problems with accurate diagnosis. PMID:26871432
Novel lectin-independent approach to detect galactose-deficient IgA1 in IgA nephropathy.
Yasutake, Junichi; Suzuki, Yusuke; Suzuki, Hitoshi; Hiura, Naoko; Yanagawa, Hiroyuki; Makita, Yuko; Kaneko, Etsuji; Tomino, Yasuhiko
2015-08-01
Galactose-deficient IgA1 (Gd-IgA1) is a critical effector molecule in the pathogenesis of IgA nephropathy (IgAN). Although many researchers have measured serum levels of Gd-IgA1 using snail helix aspersa agglutinin (HAA) lectin-based assay, the lectin-dependent assay has some serious problems in robustness. In this study, we aimed to establish a more robust and stable enzyme-linked immunosorbent assay (ELISA) method that uses a specific monoclonal antibody to recognize a hinge region in human Gd-IgA1 (Gd-IgA1 ELISA). Rats were immunized with human Gd-IgA1 hinge region peptide to obtain Gd-IgA1-specific monoclonal antibody KM55. Gd-IgA1 ELISA for specifically detecting serum Gd-IgA1 was consequently constructed. Serum Gd-IgA1 concentrations in human subjects were measured using KM55 ELISA assay. To further confirm specificity of the Gd-IgA1-specific antibody, KM55 was also applied for immunofluorescence staining of glomerular Gd-IgA1 in paraffin-embedded sections of renal biopsy specimens. Measurement of serum levels of Gd-IgA1 in human subjects by Gd-IgA1 ELISA revealed increased serum Gd-IgA1 level in patients with IgAN compared with patients with other renal diseases or non-renal diseases. Importantly, the results obtained from Gd-IgA1 ELISA positively correlated with those from the HAA lectin-based assay (R = 0.75). Immunofluorescence staining of renal biopsy specimens with KM55 detected glomerular co-localization of Gd-IgA1 and IgA. This novel lectin-independent method with KM55 for measuring serum levels of Gd-IgA1 can pave the way for more convincing diagnosis and activity assessment of IgAN, and can expedite clinical research to better understand this difficult disease. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA.
Novel lectin-independent approach to detect galactose-deficient IgA1 in IgA nephropathy
Yasutake, Junichi; Suzuki, Yusuke; Suzuki, Hitoshi; Hiura, Naoko; Yanagawa, Hiroyuki; Makita, Yuko; Kaneko, Etsuji; Tomino, Yasuhiko
2015-01-01
Background Galactose-deficient IgA1 (Gd-IgA1) is a critical effector molecule in the pathogenesis of IgA nephropathy (IgAN). Although many researchers have measured serum levels of Gd-IgA1 using snail helix aspersa agglutinin (HAA) lectin-based assay, the lectin-dependent assay has some serious problems in robustness. In this study, we aimed to establish a more robust and stable enzyme-linked immunosorbent assay (ELISA) method that uses a specific monoclonal antibody to recognize a hinge region in human Gd-IgA1 (Gd-IgA1 ELISA). Methods Rats were immunized with human Gd-IgA1 hinge region peptide to obtain Gd-IgA1-specific monoclonal antibody KM55. Gd-IgA1 ELISA for specifically detecting serum Gd-IgA1 was consequently constructed. Serum Gd-IgA1 concentrations in human subjects were measured using KM55 ELISA assay. To further confirm specificity of the Gd-IgA1-specific antibody, KM55 was also applied for immunofluorescence staining of glomerular Gd-IgA1 in paraffin-embedded sections of renal biopsy specimens. Results Measurement of serum levels of Gd-IgA1 in human subjects by Gd-IgA1 ELISA revealed increased serum Gd-IgA1 level in patients with IgAN compared with patients with other renal diseases or non-renal diseases. Importantly, the results obtained from Gd-IgA1 ELISA positively correlated with those from the HAA lectin-based assay (R = 0.75). Immunofluorescence staining of renal biopsy specimens with KM55 detected glomerular co-localization of Gd-IgA1 and IgA. Conclusion This novel lectin-independent method with KM55 for measuring serum levels of Gd-IgA1 can pave the way for more convincing diagnosis and activity assessment of IgAN, and can expedite clinical research to better understand this difficult disease. PMID:26109484
Sekiya, Shunsuke; Murata, Makoto; Arai, Satoshi; Murayama, Hiroshi; Kawasaki, Atushi; Ashida, Noriyuki; Okada, Kohki; Ikemoto, Masaki
2016-12-01
Calprotectin, a heterodimer of S100A8 and S100A9, has been reported to be a useful biomarker in inflammatory bowel disease (IBD); however, the relationship between the fecal level of S100A9 and the extent of inflammation in IBD remains unclear. Our aim was to develop a new enzyme-linked immunosorbent assay (ELISA) for rat S100A9, and to investigate whether changes in fecal S100A9 levels reflect the inflammatory conditions in the intestinal tracts of rats with dextran sulfate sodium (DSS)-induced colitis. Anti-rat S100A9 monoclonal antibodies were raised in mice and used for the development of a novel ELISA for rat S100A9. The performance of our ELISA was assessed by dilution and recovery tests, and the detection range was 3.75-240ng/mL. The dilution test showed good linearity. The recovery of fecal S100A9 was 95.1% (mean), with a range of 86.1%-108.8%. Colitis was induced in rats by oral administration of 3% DSS/drinking water (DW) for 11days (D group), while DW alone was provided to rats of the control group (C group) during the same period. The extent of inflammation was evaluated with the disease activity index (DAI), and the concentration of fecal S100A9 was determined by ELISA. Both the DAI scores and the fecal S100A9 levels were significantly higher in the D group than in the C group. Microscopic observation revealed that S100A9 was dominantly produced in many immune cells of myeloid origin in rat rectal tissues. These results indicate that the novel ELISA may be applied to clinically evaluate IBD in rats with high sensitivity. In conclusion, our ELISA is useful in toxicological and pharmacological evaluations. Copyright © 2016 Elsevier B.V. All rights reserved.
Increased Sensitivity of HIV-1 p24 ELISA Using a Photochemical Signal Amplification System.
Bystryak, Simon; Santockyte, Rasa
2015-10-01
In this study we describe a photochemical signal amplification method (PSAM) for increasing of the sensitivity of enzyme-linked immunosorbent assay (ELISA) for determination of HIV-1 p24 antigen. The photochemical signal amplification method is based on an autocatalytic photochemical reaction of a horseradish peroxidase (HRP) substrate, orthophenylenediamine (OPD). To compare the performance of PSAM-boosted ELISA with a conventional colorimetric ELISA for determination of HIV-1 p24 antigen we employed a PerkinElmer HIV-1 p24 ELISA kit, using conventional ELISA alongside ELISA + PSAM. In the present study, we show that PSAM technology allows one to increase the analytical sensitivity and dynamic range of a commercial HIV-1 p24 ELISA kit, with and without immune-complex disruption, by a factor of approximately 40-fold. ELISA + PSAM is compatible with commercially available microtiter plate readers, requires only an inexpensive illumination device, and the PSAM amplification step takes no longer than 15 min. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods.
[Evaluation of the Performance of Two Kinds of Anti-TP Enzyme-Linked Immunosorbent Assay].
Gao, Nan; Huang, Li-Qin; Wang, Rui; Jia, Jun-Jie; Wu, Shuo; Zhang, Jing; Ge, Hong-Wei
2018-06-01
To evaluate the accuracy and precision of 2 kinds of anti-treponema pallidum (anti-TP) ELISA reagents in our laboratory for detecting the anti-TP in voluntary blood donors, so as to provide the data support for use of ELISA reagents after introduction of chemiluminescene immunoassay (CLIA). The route detection of anti-TP was performed by using 2 kinds of ELISA reagents, then 546 responsive positive samples detected by anti-TP ELISA were collected, and the infections status of samples confirmed by treponema pallidum particle agglutination (TPPA) test was identified. The confirmed results of responsive samples detected by 2 kinds of anti-TP ELISA reagents were compared, the accuracy of 2 kinds of anti-TP ELISA reagents was analyzed by drawing ROC and comparing area under curve (AUC), and precision of 2 kinds of anti-TP ELISA reagents was compared by statistical analysis of quality control data from 7.1 2016 to 6.30 2017. There were no statistical difference in confirmed positive rate of responsive samples and weak positive samples between 2 kinds of anti-TP ELISA reagents. The responsive samples detected by 2 kinds of anti-TP ELISA reagents accounted for 85.53%(467/546) of all responsive samples, the positive rate confirmed by TPPA test was 82.87%. 44 responsive samples detected by anti-TP ELISA reagent A and 35 responsive samples detected by anti-TP ELISA reagent B were confirmed to be negative by TPPA test. Comparison of AUC showed that the accuracy of 2 kinds of anti-TP ELISA reagents was more high, the difference between 2 reagents was not statistically significant. The coefficient of variation (CV) of anti-TP ELISA reagent A and B was 14.98% and 18.04% respectively, which met the precision requirement of ELISA test. The accuracy and precision of 2 kinds of anti-TP ELISA reagents used in our laboratory are similar, and using any one of anti-TP ELISA reagents all can satisfy the requirements of blood screening.
Serological trail of Brucella infection in an urban slum population in Brazil
Angel, Martha Olivera; Ristow, Paula; Ko, Albert I.; Di-Lorenzo, Cecilia
2013-01-01
Introduction Brucellosis is a re-emerging zoonosis with new cases reported each year in many Latin American countries, but it is mostly under-recognized. This study presents a serological investigation of infection with Brucella abortus and Brucella canis in a poor urban community in the city of Salvador, Brazil. Methodology Human sera (n = 180) were randomly selected from 3,171 samples taken from healthy individuals during 2003-2004 and tested with C-ELISA for B. abortus and I-ELISA for B. canis. Results Thirteen percent (24/180) of the individuals were positive for B. abortus and 4.6 % (8/174) were positive for B. canis. Among the variables studied only age (older than 45 years) appeared to be a risk factor for the detection of Brucella antibodies. Conclusion These results indicate the presence of Brucella infection in this settlement and highlight the need to understand the epidemiology of infection under these circumstances to establish the necessary measures for surveillance and control. PMID:23000868
Zhang, Jingyang; Chaloner, Kathryn; McLinden, James H.; Stapleton, Jack T.
2013-01-01
Reconciling two quantitative ELISA tests for an antibody to an RNA virus, in a situation without a gold standard and where false negatives may occur, is the motivation for this work. False negatives occur when access of the antibody to the binding site is blocked. Based on the mechanism of the assay, a mixture of four bivariate normal distributions is proposed with the mixture probabilities depending on a two-stage latent variable model including the prevalence of the antibody in the population and the probabilities of blocking on each test. There is prior information on the prevalence of the antibody, and also on the probability of false negatives, and so a Bayesian analysis is used. The dependence between the two tests is modeled to be consistent with the biological mechanism. Bayesian decision theory is utilized for classification. The proposed method is applied to the motivating data set to classify the data into two groups: those with and those without the antibody. Simulation studies describe the properties of the estimation and the classification. Sensitivity to the choice of the prior distribution is also addressed by simulation. The same model with two levels of latent variables is applicable in other testing procedures such as quantitative polymerase chain reaction tests where false negatives occur when there is a mutation in the primer sequence. PMID:23592433
Bioassay-guided isolation of proanthocyanidins with antiangiogenic activities.
Pesca, Maria S; Dal Piaz, Fabrizio; Sanogo, Rokia; Vassallo, Antonio; Bruzual de Abreu, Maryan; Rapisarda, Antonio; Germanò, Maria P; Certo, Giovanna; De Falco, Sandro; De Tommasi, Nunziatina; Braca, Alessandra
2013-01-25
The proangiogenic members of the vascular endothelial growth factor (VEGF) family and related receptors play a central role in the modulation of pathological angiogenesis. In order to identify plant compounds able to interfere in the VEGFs/VEGFR-1 (Flt-1) recognition by VEGF family members, the extracts of the aerial parts of Campsiandra guayanensis and Feretia apodanthera were screened by a competitive ELISA-based assay. By using this bioassay-oriented approach five proanthocyanindins, including the new natural compounds (2S)-4',5,7-trihydroxyflavan-(4β→8)-afzelechin (1) and (2S)-4',5,7-trihydroxyflavan-(4β→8)-epiafzelechin (2) and the known geranin B (3), proanthocyanidin A2 (4), and proanthocyanidin A1 (5), were isolated. The study of the antiangiogenic activities of compounds 1-5 using ELISA and SPR assays showed compound 1 as being the most active. The antiangiogenic activity of 1 was also confirmed in vivo by the chicken chorioallantoic membrane assay. Our results indicated 1 as a new antiangiogenic compound inhibiting the interaction between VEGF-A or PlGF and their receptor VEGRF-1.
NASA Astrophysics Data System (ADS)
Crescio, Claudia; Orecchioni, Marco; Ménard-Moyon, Cécilia; Sgarrella, Francesco; Pippia, Proto; Manetti, Roberto; Bianco, Alberto; Delogu, Lucia Gemma
2014-07-01
Spaceflights lead to dysregulation of the immune cell functionality affecting the expression of activation markers and cytokine production. Short oxidized multi-walled carbon nanotubes functionalized by 1,3-dipolar cycloaddition have been reported to activate immune cells. In this Communication we have performed surface marker assays and multiplex ELISA on primary monocytes and T cells under microgravity. We have discovered that carbon nanotubes, through their immunostimulatory properties, are able to fight spaceflight immune system dysregulations.Spaceflights lead to dysregulation of the immune cell functionality affecting the expression of activation markers and cytokine production. Short oxidized multi-walled carbon nanotubes functionalized by 1,3-dipolar cycloaddition have been reported to activate immune cells. In this Communication we have performed surface marker assays and multiplex ELISA on primary monocytes and T cells under microgravity. We have discovered that carbon nanotubes, through their immunostimulatory properties, are able to fight spaceflight immune system dysregulations. Electronic supplementary information (ESI) available: Experimental section, structures of f-MWCNTs and uptake by human primary immune cells. See DOI: 10.1039/c4nr02711f
Wang, Shujie J; Wu, Steven T; Gokemeijer, Jochem; Fura, Aberra; Krishna, Murli; Morin, Paul; Chen, Guodong; Price, Karen; Wang-Iverson, David; Olah, Timothy; Weiner, Russell; Tymiak, Adrienne; Jemal, Mohammed
2012-01-01
High-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-linked immunosorbent assay (ELISA) methods were developed for the quantification of a PEGylated scaffold protein drug in monkey plasma samples. The LC-MS/MS method was based on the extraction of the therapeutic protein with a water-miscible organic solvent and the subsequent trypsin digestion of the extract followed by the detection of a surrogate peptide. The assay was linear over a range of 10-3,000 ng/mL. The ELISA method utilized a therapeutic target-binding format in which the recombinant target antigen was used to capture the drug in the sample, followed by detection with an anti-PEG monoclonal antibody. The assay range was 30-2,000 ng/mL. A correlation study between the two methods was performed by measuring the drug concentrations in plasma samples from a single-dose pharmacokinetic (PK) study in cynomolgus monkeys following a 5-mg/kg subcutaneous administration (n = 4). In the early time points of the PK profile, the drug concentrations obtained by the LC-MS/MS method agreed very well with those obtained by the ELISA method. However, at later time points, the drug concentrations measured by the LC-MS/MS method were consistently higher than those measured by the ELISA method. The PK parameters calculated based on the concentration data showed that the two methods gave equivalent peak exposure (C(max)) at 24-48 h. However, the LC-MS/MS results exhibited about 1.53-fold higher total exposure (AUC(tot)) than the ELISA results. The discrepancy between the LC-MS/MS and ELISA results was investigated by conducting immunogenicity testing, anti-drug antibody (ADA) epitope mapping, and Western blot analysis of the drug concentrations coupled with Protein G separation. The results demonstrated the presence of ADA specific to the engineered antigen-binding region of the scaffold protein drug that interfered with the ability of the drug to bind to the target antigen used in the ELISA method. In the presence of the ADAs, the ELISA method measured only the active circulating drug (target-binding), while the LC-MS/MS method measured the total circulating drug. The work presented here indicates that the bioanalysis of protein drugs may be complicated owing to the presence of drug-binding endogenous components or ADAs in the post-dose (incurred) samples. The clear understanding of the behavior of different bioanalytical techniques vis-à-vis the potentially interfering components found in incurred samples is critical in selecting bioanalytical strategies for measuring protein drugs.
Nakayasu, Miki; Hirano, Minato; Muto, Memi; Kobayashi, Shintaro; Kariwa, Hiroaki; Yoshii, Kentaro
2018-06-23
Tick-borne encephalitis virus (TBEV) is a zoonotic agent causing severe encephalitis in humans. IgM antibody detection is useful for the serological diagnosis of TBEV infection, because IgM has high specificity for each flavivirus and indicates a recent infection. Commercial IgM-ELISA kits are somewhat expensive and difficulties in their sensitivity have been suggested due to their format and formalin-inactivated antigens. Therefore, the development of an inexpensive IgM-ELISA with high specificity and sensitivity is needed. In this study, a μ-capture ELISA was developed to detect TBEV-specific IgM antibodies using subviral particles (SPs) with strep-tag (strep-SP-IgM-ELISA). The results of our strep-SP-IgM-ELISA were highly correlated with diagnoses made by the neutralization test (sensitivity: 94.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in patients who could not be diagnosed with the neutralization test. Besides, 51 of 52 positive samples by a commercial IgM-ELISA were also diagnosed as positive by our strep-SP-IgM-ELISA (98.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in all samples that were inconclusive based on the commercial IgM-ELISA. Our strep-SP-IgM-ELISA will be useful for diagnoses in TBE-endemic areas. Copyright © 2018 Elsevier GmbH. All rights reserved.
Katz, David; Shi, Wei; Patrusheva, Irina; Perelygina, Ludmila; Gowda, Manjunath S; Krug, Peter W; Filfili, Chadi N; Ward, John A; Hilliard, Julia K
2012-01-01
B virus (Macacine herpesvirus 1) occurs naturally in macaques and can cause lethal zoonotic infections in humans. Detection of B virus (BV) antibodies in macaques is essential for the development of SPF breeding colonies and for diagnosing infection in macaques that are involved in human exposures. Traditionally, BV infections are monitored for presence of antibodies by ELISA (a screening assay) and western blot analysis (WBA; a confirmatory test). Both tests use lysates of infected cells as antigens. Because WBA often fails to confirm the presence of low-titer serum antibodies detected by ELISA, we examined a recombinant-based ELISA as a potential alternative confirmatory test. We compared a high-throughput ELISA using 384-well plates for simultaneous antibody screening against 4 BV-related, recombinant proteins with the standard ELISA and WBA. The recombinant ELISA results confirmed more ELISA-positive sera than did WBA. The superiority of the recombinant ELISA over WBA was particularly prominent for sera with low (<500 ELISA units) antibody titers. Among low-titer sera, the relative sensitivity of the recombinant ELISA ranged from 36.7% to 45.0% as compared with 3.3% to 10.0% for WBA. In addition, the screening and confirmatory assays can be run simultaneously, providing results more rapidly. We conclude that the recombinant ELISA is an effective replacement for WBA as a confirmatory assay for the evaluation of macaque serum antibodies to BV. PMID:23561887
Reassessing the Detection of B-Virus–Specific Serum Antibodies
Katz, David; Shi, Wei; Wildes, Martin J; Krug, Peter W; Hilliard, Julia K
2012-01-01
B virus, a natural pathogen of macaques, can cause a fatal zoonotic disease in humans. Serologic screening of macaques by titration ELISA (tELISA, screening test) and by Western blot analysis (WBA, confirmatory test) is one of the principle measures to prevent human infection. Here we slightly modified these 2 tests and reevaluated their correlation. We developed a high-throughput tELISA and used it to screen 278 sera simultaneously against the homologous BV antigen and the heterologous antigens of Papiine herpesvirus 2 and Human herpesvirus 1. More sera (35.6%) were positive by the BV-ELISA than by the HVP2-ELISA (21.6%) or HSV1-ELISA (19.8%). The superiority of the homologous tELISA over the heterologous tELISA was prominent in low-titer sera. WBA confirmed only 21% of the tELISA-positive sera with low or intermediate antibody titers. These sera might have contained antibodies to conformational epitopes that could not be detected by WBA, in which denatured antigens are used, but that could be detected by tELISA, which detects both linear and conformational epitopes. WBA confirmed 82% of the tELISA high-titer sera. However, WBA defined the remaining 18% of sera, which were negative by tELISA, as nonnegative. This finding can be attributed to the difficulties encountered with the subjective interpretation of results by WBA. Together, the current results indicate the inadequacy of WBA as a confirmatory assay for sera with low antibody titers. PMID:23561886
Dzagurova, T K; Solopova, O N; Sveshnikov, P G; Korotina, N A; Balovneva, M V; Leonovich, O A; Varlamov, N E; Malkin, G A; Sotskova, S E; Tkachenko, E A
2013-01-01
The monoclonal antibodies to Puumala, Dobrava, Hantaan, and Seoul hantaviruses were obtained using mice. The viruses were known to cause HFRS, and two variants of ELISA were designed. First, Hanta-PUU variant, was constructed using monoclonal antibodies to Puumala virus envelope glycoprotein (G(N):G(C)) for detecting only Puumala virus antigen. The second, Hanta-N variant, was constructed using monoclonal antibodies to Dobrava and Puumala nucleocapsid proteins for detecting four above mentioned hantaviruses. Both Hanta-PUU and Hanta-N assays were reliable in detecting specific hantavirus antigens and the immunogenecity of hantavirus vaccines.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław
2017-09-01
The study was conducted to evaluate influence of the true within-herd prevalence of small ruminant lentivirus (SRLV) infection on agreement beyond chance between three different types of commercial serological ELISAs. Blood samples were collected from 865 goats from 12 dairy goat herds. Serum samples were tested using three commercial ELISA kits: whole-virus indirect ELISA (wELISA), indirect ELISA based on recombined TM and CA antigens (TM/CA-ELISA), and competitive-inhibition ELISA based on SU antigen (SU-ELISA). Herds were classed into three prevalence strata of high (>50%), moderate (10-50%) and low (<10%) true within-herd prevalence of SRLV infection. The latter was estimated on the basis of results of wELISA adjusted by its sensitivity and specificity. Agreement beyond chance between the three ELISAs was assessed at two levels. First, the general agreement was determined using two coefficients corrected for chance-agreement: Cohen's kappa and Gwet's AC 1 . Then, agreement between tests was evaluated using Gwet's AC 1 separately in the three prevalence strata and compared between them by computing 95% confidence intervals for differences with a Bonferroni correction for multiple comparisons. The general agreement between the three tests was very good: wELISA and TM/CA-ELISA - Cohen's kappa of 81.8% (CI 95%: 77.9% to 85.7%), Gwet's AC 1 of 82.7% (CI 95%: 79.0% to 86.4%); wELISA and SU-ELISA - Cohen's kappa of 83.2% (CI 95%: 79.4% to 86.9%), Gwet's AC 1 of 83.9% (CI 95%: 80.4% to 87.5%); TM/CA-ELISA and SU-ELISA - Cohen's kappa of 86.0% (CI 95%: 82.6% to 89.5%), Gwet's AC 1 of 86.9% (CI 95%: 83.6% to 90.1%). However, agreement between ELISAs was significantly related to the within-herd true prevalence - it was significantly lower (although still high) when within-herd true prevalence was moderate (Gwet's AC 1 between 67.2% and 78.7%), whereas remained very high, when true within-herd prevalence was either >50% (Gwet's AC 1 between 91.9% and 98.8%) or <10% (Gwet's AC 1 between 94.7% and 98.4%). Concluding, the three different commercial ELISAs for SRLV infection in goats available on the market yield highly consistent results. However, their agreement is affected by the true within-herd prevalence in a tested population, and the worse (although still high) agreement should be expected, when the percentage of infected goats is moderate. Copyright © 2017 Elsevier B.V. All rights reserved.
van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara
2008-01-01
Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832
Li, Ren; Qiu, Li-hong; Yang, Di; Xue, Ming; Zhong, Ming
2011-03-01
To observe the effect of lipopolysaccharides (LPS) extracted from Porphyromonas endodontalis (Pe) on osteoblast cell proliferation and the activity of alkaline phosphatase (ALP) and interleukin (IL)-6 secretion and to investigate the role of Pe-LPS in osteoblast proliferation and differentiation. MC3T3-E1 cells were treated with different concentrations of Pe-LPS (10, 25, 50 mg/L) respectively. The relative growth rate (RGR) was detected by methyl thiazolyl tetrazolium (MTT) at different time point (12, 24, 48, 72 h). MC3T3-E1 cells were also stimulated with 10, 25 or 50 mg/L Pe-LPS for 6, 12, 24 and 48 h. The activity of ALP was detected by enzyme kinetics assay and the secretion of IL-6 was detected by enzyme-linked immunosorbent assay (ELISA). After the stimulation with 25 or 50 mg/L Pe-LPS for 72 h, the RGR of MC3T3-E1 cells descend to 87.46% and 71.12%. The ALP activities of MC3T3-E1 cells were inhibited obviously (P < 0.05) after the stimulation of different concentrations (10, 25, 50 mg/L) Pe-LPS for more than 24 hours. ELISA result showed that IL-6 increased to 32.21 ng/L treated with the 25 mg/L Pe-LPS for 6 h, 25 mg/L Pe-LPS gradually increased the expression of IL-6 from the ELISA results. Pe-LPS can induce the secretion of IL-6 in MC3T3-E1 and decrease the ALP activities of MC3T3-E1, the differentiation of osteoblasts was inhibited. with the long-time toxicity action of Pe-LPS, the proliferation rate of MC3T3-E1 also markedly decreased.
Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio
2013-01-01
A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700
Agreement between commercial assays for haptoglobin and serum amyloid A in goats.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Reczyńska, Daria; Bagnicka, Emilia; Kaba, Jarosław
2017-10-02
Haptoglobin (Hp) and serum amyloid A (SAA) are considered as the major acute phase proteins (APPs) in goats. These APPs have been investigated in several studies during the last decade. In most studies, a colorimetric assay for Hp and a solid phase sandwich ELISA for SAA have been used for quantification. In 2015, reference intervals for APPs were determined using a new type of assay, the competitive ELISA (cELISA). Results obtained by the cELISA differed significantly from results obtained by previously used assays. The present study aimed to assess the agreement between so far used assays and cELISAs. Sera of 152 female dairy goats of two Polish national breeds were analysed. The concentration of Hp was determined using a colorimetric assay (Hp-CA) and the cELISA (Hp-cELISA), while a solid phase sandwich ELISA (SAA-sELISA) and the cELISA (SAA-cELISA) were used to measure SAA. Agreement between test results was assessed by preparing Bland-Altman plots, and analyzing 95% limits of agreement (LoA). Finally, the assays for Hp and SAA were compared using 147 and 138 serum samples, respectively, as 5 and 14 paired measurements, respectively, were excluded from agreement analyses to avoid extrapolation of Hp and SAA concentration. Measurements obtained by the Hp-CA and Hp-cELISA showed weak positive correlation (r = 0.24, P = 0.003). Limits of agreement (LoA) ranged from + 1.6 (95% CI 1.4 to 1.8) g/L to - 1.5 (95% CI - 1.7 to - 1.3) g/L. Measurements yielded by the SAA-sELISA and SAA-cELISA did not correlate (r = - 0.01, P = 0.855). LoA ranged from + 14.5 mg/L (95% CI 12.9 to 16.1) to - 8.5 mg/L (95% CI - 10.1 to - 6.9). Agreement between the two types of commercial assays for determination of Hp and SAA concentrations in goats is poor and cELISAs tend to underrate both Hp and SAA concentrations.
B cell epitopes on infliximab identified by oligopeptide microarray with unprocessed patient sera.
Homann, Arne; Röckendorf, Niels; Kromminga, Arno; Frey, Andreas; Jappe, Uta
2015-10-29
Autoimmune diseases like rheumatoid arthritis and inflammatory bowel disease are treated with TNF-alpha-blocking antibodies such as infliximab and adalimumab. A common side effect of therapeutic antibodies is the induction of anti-drug antibodies, which may reduce therapeutic efficacy. In order to reveal immunogenic epitopes on infliximab which are responsible for the adverse effects, sera from patients treated with infliximab were screened by ELISA for anti-infliximab antibodies. Sera containing high levels of anti-drug-antibodies (>1.25 µg/ml) were analyzed in an oligopeptide microarray system containing immobilized 15-meric oligopeptides from the infliximab amino acid sequence. Immunogenic infliximab IgG-epitopes were identified by infrared fluorescence scanning and comparison of infliximab-treated patients versus untreated controls. Six relevant epitopes on infliximab were recognized by the majority of all patient sera: 4 in the variable and 2 in the constant region. Three of the epitopes in the variable region are located in the TNF-alpha binding region of infliximab. The fourth epitope of the variable part of infliximab is located close to the TNF-alpha binding region and contains an N-glycosylation sequon. The sera positive for anti-infliximab antibodies do not contain antibodies against adalimumab as determined by ELISA. Thus, there is no infliximab-adalimumab cross-reactivity as determined by these systems. Our data shall contribute to a knowledge-based recommendation for a potentially necessary therapy switch from infliximab to another type of TNF-alpha-blocker. The characterization of immunogenic epitopes on therapeutic monoclonal antibodies using unprocessed patient sera shall lead to direct translational aspects for the development of less immunogenic therapeutic antibodies. Patients benefit from less adverse events and longer lasting drug effects.
Nieto Cárdenas, Olga Alicia
2015-11-01
To describe the relationship between metalloproteinase (MMP) 2, MMP-9, and leptin in drivers of public service vehicles with metabolic syndrome in the city of Armenia (Quindio, Colombia). Leptin was measured using Millipore ELISA kits. MMP-2 and MMP-9 were measured with ELISA kits from R&D Systems. Fifty-seven male drivers with metabolic syndrome with a mean age of 45.35years, BMI of 29.81, and an abdominal circumference of 105.75cm were identified. Blood pressure values were 126.5/82.5mmHg. Leptin, MMP-2, and MMP-9 levels were 24.6ng/mL, 28,1ng/mL, and 7.5ng/mL respectively. The relationship between leptin and waist circumference was statistically significant (P<.001). The explained variation (R(2)) in waist circumference, is explained in a 80.12% for the study variables, has a statistically significant association with BMI (P<.001), MMP-2 (P=.01), age (P=.01), SBP (P<.001) and DBP (P<.001). The R(2) of leptin, is explained in a 69.56% for the study variables, has a statistically significant association with BMI (P<.001), MMP-2 (P=.05) and triglycerides (P=.02). The R(2) of MMP-2, explained in 41.82% of the study variables and has a statistically significant association with waist circumference (P=.01), glucose (P=.01) and age (P=.03). Statistically significant associations were found between waist circumference and MMP-2; leptin and MMP-2, and MMP-2 and waist circumference and blood glucose. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P
2008-07-27
A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.
Schiavo, M; Bagnara, M C; Pomposelli, E; Altrinetti, V; Calamia, I; Camerieri, L; Giusti, M; Pesce, G; Reitano, C; Bagnasco, M; Caputo, M
2013-09-01
Radioiodine is a common option for treatment of hyperfunctioning thyroid nodules. Due to the expected selective radioiodine uptake by adenoma, relatively high "fixed" activities are often used. Alternatively, the activity is individually calculated upon the prescription of a fixed value of target absorbed dose. We evaluated the use of an algorithm for personalized radioiodine activity calculation, which allows as a rule the administration of lower radioiodine activities. Seventy-five patients with single hyperfunctioning thyroid nodule eligible for 131I treatment were studied. The activities of 131I to be administered were estimated by the method described by Traino et al. and developed for Graves'disease, assuming selective and homogeneous 131I uptake by adenoma. The method takes into account 131I uptake and its effective half-life, target (adenoma) volume and its expected volume reduction during treatment. A comparison with the activities calculated by other dosimetric protocols, and the "fixed" activity method was performed. 131I uptake was measured by external counting, thyroid nodule volume by ultrasonography, thyroid hormones and TSH by ELISA. Remission of hyperthyroidism was observed in all but one patient; volume reduction of adenoma was closely similar to that assumed by our model. Effective half-life was highly variable in different patients, and critically affected dose calculation. The administered activities were clearly lower with respect to "fixed" activities and other protocols' prescription. The proposed algorithm proved to be effective also for single hyperfunctioning thyroid nodule treatment and allowed a significant reduction of administered 131I activities, without loss of clinical efficacy.
Sobarzo, Ariel; Stonier, Spencer W.; Herbert, Andrew S.; Ochayon, David E.; Kuehne, Ana I.; Eskira, Yael; Fedida-Metula, Shlomit; Tali, Neta; Lewis, Eli C.; Egesa, Moses; Cose, Stephen; Lutwama, Julius Julian; Yavelsky, Victoria; Dye, John M.; Lobel, Leslie
2016-01-01
Robust humoral and cellular immunity are critical for survival in humans during an ebolavirus infection. However, the interplay between these two arms of immunity is poorly understood. To address this, we examined residual immune responses in survivors of the Sudan virus (SUDV) outbreak in Gulu, Uganda (2000–2001). Cytokine and chemokine expression levels in SUDV stimulated whole blood cultures were assessed by multiplex ELISA and flow cytometry. Antibody and corresponding neutralization titers were also determined. Flow cytometry and multiplex ELISA results demonstrated significantly higher levels of cytokine and chemokine responses in survivors with serological neutralizing activity. This correspondence was not detected in survivors with serum reactivity to SUDV but without neutralization activity. This previously undefined relationship between memory CD4 T cell responses and serological neutralizing capacity in SUDV survivors is key for understanding long lasting immunity in survivors of filovirus infections. PMID:27187443
Sobarzo, Ariel; Stonier, Spencer W; Herbert, Andrew S; Ochayon, David E; Kuehne, Ana I; Eskira, Yael; Fedida-Metula, Shlomit; Tali, Neta; Lewis, Eli C; Egesa, Moses; Cose, Stephen; Lutwama, Julius Julian; Yavelsky, Victoria; Dye, John M; Lobel, Leslie
2016-05-11
Robust humoral and cellular immunity are critical for survival in humans during an ebolavirus infection. However, the interplay between these two arms of immunity is poorly understood. To address this, we examined residual immune responses in survivors of the Sudan virus (SUDV) outbreak in Gulu, Uganda (2000-2001). Cytokine and chemokine expression levels in SUDV stimulated whole blood cultures were assessed by multiplex ELISA and flow cytometry. Antibody and corresponding neutralization titers were also determined. Flow cytometry and multiplex ELISA results demonstrated significantly higher levels of cytokine and chemokine responses in survivors with serological neutralizing activity. This correspondence was not detected in survivors with serum reactivity to SUDV but without neutralization activity. This previously undefined relationship between memory CD4 T cell responses and serological neutralizing capacity in SUDV survivors is key for understanding long lasting immunity in survivors of filovirus infections.
Lacrimal secretory IgA in active posterior uveitis induced by Toxoplasma gondii.
Lynch, Maria Isabel; Cordeiro, Francisco; Ferreira, Silvana; Ximenes, Ricardo; Oréfice, Fernando; Malagueño, Elizabeth
2004-12-01
It is quite difficult to diagnose active toxoplasmosis in patients with ocular toxoplasmosis. Active posterior uveitis presumably due to Toxoplasma gondii infection (APUPT) is seldom produced during a prime-infection; hence most patients do not show high IgM antibodies. High levels of IgA have been described in active toxoplasmosis. The purpose of this study was to investigate possible association between APUPT and the specific anti-parasite sIgA in tears. The study was carried out as case-control. Tears of 25 clinically confirmed APUPT patients and 50 healthy control subjects were analyzed. All were IgG seropositive. Specific sIgA was determined by ELISA assay using T. gondii RH strain crude extract. Anti-T. gondii sIgA was found in 84% of the cases and in 22% of the control subjects. The intensity of the reaction was higher in APUPT cases (P = 0.007). There was strong association between APUPT patients and lacrimal sIgA (odds-ratio 18.61, P = 0.0001). ELISA test sensitivity was 84% and specificity 78%. Our data suggest that anti-T.gondii secretory IgA found in tears may become an important marker for active ocular toxoplasmosis.
[Study of the antitumor activity of alveolar macrophages after transfected human INF-γ gene].
Zhou, Fengli; Bi, Xiaogang; Zhang, Tiantuo; Huang, Jing
2011-05-01
Alveolar macrophages (AMs) activated have the antitumor activity. The interferon-γ (INF-γ) is one of the stimulating factors. INF-γ can enhance the immune function of AMs in vitro. The aim of this study is to investigate the effect of human INF-γ gene on the antitumor activity of AMs when transfected into the alveolar macrophages (AMs) from the patients with lung cancer in vitro. AMs obtained by brochoalveolar lavage were separated and transfected by INF-γ gene. RT-PCR and ELISA were applied to determine whether the transfection was successful. The levels of tumor necrosis factor α (TNF-α), nitric oxide (NO) and interleukin-1 (IL-1) produced by AMs and the killing activity of AMs against L1210 cells was detected respectively. Both RT-PCR and ELISA demonstrated that human INF-γ gene had been successfully transfected into AMs. When transfected by human INF-γ gene, the levels of TNF-α, NO and IL-1 produced by AMs from the patients with lung cancer and the killing activity of AMs against L1210 cells were significantly higher than those of the control groups. Human INF-γ gene can enhance the antitumor activity of AMs when transfected into AMs from the patients with lung cancer.
Sandwich-dot enzyme-linked immunosorbent assay for the detection of canine distemper virus
Li, Zhi; Zhang, Yanlong; Wang, Huiguo; Jin, Jinhua; Li, Wenzhe
2013-01-01
A sandwich-dot enzyme-linked immunosorbent assay (dot ELISA) was developed for the detection of canine distemper virus (CDV). In 56 dogs suspected to have CD the rates of detection of CDV antigen in samples of blood lymphocytes and palpebral conjunctiva by dot ELISA and ELISA were, respectively, 91% (49/54) and 81% (44/54) for the lymphocyte samples and 88% (28/32) and 75% (24/32) for the conjunctival samples. The CDV detection limits were 10 ng/50 μL for dot ELISA and 40 ng/50 μL for ELISA. The reliability of dot ELISA relative to electron microscopy was 96% with 22 samples: all 21 samples in which CDV particles were observed by electron microscopy yielded positive results with dot ELISA; the single sample in which particles were not observed yielded false-positive results with dot ELISA. The results indicate that the dot ELISA developed can serve as a reliable rapid diagnostic test in suspected cases of CD and also be useful for epidemiologic surveillance of the disease. PMID:24124274
Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.
2012-01-01
Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675
Kojima, Hajime; Takeyoshi, Masahiro; Sozu, Takashi; Awogi, Takumi; Arima, Kazunori; Idehara, Kenji; Ikarashi, Yoshiaki; Kanazawa, Yukiko; Maki, Eiji; Omori, Takashi; Yuasa, Atsuko; Yoshimura, Isao
2011-01-01
The murine local lymph node assay (LLNA) is a well-established alternative to the guinea pig maximization test (GPMT) or Buehler test (BT) for the assessment of the skin sensitizing ability of a drug, cosmetic material, pesticide or industrial chemical. Instead of radioisotope using in this method, Takeyoshi M. et al. (2001) has developed a modified LLNA based on the 5-bromo-2'-deoxyuridine (BrdU) incorporation (LLNA:BrdU-ELISA). The LLNA:BrdU-ELISA is practically identical to the LLNA methodology excluding the use of BrdU, for which a single intraperitoneal injection of BrdU is made on day 4, and colorimetric detection of cell turnover. We conducted the validation study to evaluate the reliability and relevance of LLNA:BrdU-ELISA. The experiment involved 7 laboratories, wherein 10 chemicals were examined under blinded conditions. In this study, 3 chemicals were examined in all laboratories and the remaining 7 were examined in 3 laboratories. The data were expressed as the BrdU incorporation using an ELISA method for each group, and the stimulation index (SI) for each chemical-treated group was determined as the increase in the BrdU incorporation relative to the concurrent vehicle control group. An SI of 2 was set as the cut-off value for exhibiting skin sensitization activity. The results obtained in the experiments conducted for all 10 chemicals were sufficiently consistent with small variations in their SI values. The sensitivity, specificity, and accuracy of LLNA:BrdU-ELISA against those of GPMT/BT were 7/7 (100%), 3/3 (100%), and 10/10 (100%), respectively. Copyright © 2010 John Wiley & Sons, Ltd.
Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction.
Eble, Johannes A
2018-02-15
The dissociation constant describes the interaction between two partners in the binding equilibrium and is a measure of their affinity. It is a crucial parameter to compare different ligands, e.g., competitive inhibitors, protein isoforms and mutants, for their binding strength to a binding partner. Dissociation constants are determined by plotting concentrations of bound versus free ligand as binding curves. In contrast, titration curves, in which a signal that is proportional to the concentration of bound ligand is plotted against the total concentration of added ligand, are much easier to record. The signal can be detected spectroscopically and by enzyme-linked immunosorbent assay (ELISA). This is exemplified in a protocol for a titration ELISA that measures the binding of the snake venom-derived rhodocetin to its immobilized target domain of α2β1 integrin. Titration ELISAs are versatile and widely used. Any pair of interacting proteins can be used as immobilized receptor and soluble ligand, provided that both proteins are pure, and their concentrations are known. The difficulty so far has been to determine the dissociation constant from a titration curve. In this study, a mathematical function underlying titration curves is introduced. Without any error-prone graphical estimation of a saturation yield, this algorithm allows processing of the raw data (signal intensities at different concentrations of added ligand) directly by mathematical evaluation via non-linear regression. Thus, several titration curves can be recorded simultaneously and transformed into a set of characteristic parameters, among them the dissociation constant and the concentration of binding-active receptor, and they can be evaluated statistically. When combined with this algorithm, titration ELISAs gain the advantage of directly presenting the dissociation constant. Therefore, they may be used more efficiently in the future.
Ye, C; Luo, J; Wang, X; Xi, J; Pan, Y; Chen, J; Yang, X; Li, G; Sun, Q; Yang, J
2017-11-01
Hepatitis A virus (HAV) is a highly infectious agent that causes acute liver disease. The infection can trigger the production of antibodies against the structural and non-structural proteins of HAV. Nonetheless, vaccination with an HAV vaccine leads to the production of a primary antibody against the structural proteins. Because the non-structural proteins are only produced during active virus replication, there is no or very little antibody production against the non-structural proteins. However, the current commercial immunoassay cannot distinguish between antibodies produced during natural infection and those from vaccination against HAV. In our study, six immune-dominant epitopes from the non-structural proteins were designed, synthesized, linked together and cloned into pGEX-5X-1 plasmid. The recombinant protein was expressed in E. coli and purified by Ni 2+ -coated magnetic agarose beads. Then the purified recombinant protein was used as an ELISA antigen to detect antibodies for HAV non-structural proteins in serum samples. Seventy-seven attenuated and 89 inactivated vaccinated samples collected from our previous phase IV study of HAV vaccines were detected by peptide ELISA developed in this study. The mean OD 450 value for the vaccination samples and acute infection samples were 0.529 (0.486 for the attenuated group and 0.567 for the inactivated group) and 1.187, respectively. According to the receiver operating characteristic (ROC) curve, the sensitivity and specificity of the peptide ELISA were 93.80% and 91.00%, respectively. This peptide ELISA was confirmed to discriminate vaccine-induced immunity from natural infection of HAV in a phase IV study with high sensitivity and specificity.
Mason, Kathleen L; Gonzalez, Michael V; Chung, Chungwon; Mousel, Michelle R; White, Stephen N; Taylor, Joshua B; Scoles, Glen A
2017-09-01
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identified using nested PCR (nPCR) as the gold standard. Negative bovine control sera supplied with the kit were used to calculate % inhibition (%I), designated bovine control ELISA (BcELISA), and this was compared to %I calculated from negative ovine sera derived from hand-raised, pathogen-free sheep, designated ovine control ELISA (OcELISA). The receiver operating characteristics area under the curve was 1.0 with a p value <0.001 regardless of the source of the control sera. The cutoff values for negative BcELISA and OcELISA were <30%I and <27%I, respectively. Our work confirmed that this Anaplasma antibody cELISA kit version 2 can be used with the serum controls supplied in the kit to test for A. ovis antibody in domestic sheep. Furthermore, this work confirmed the historically high infection prevalence (>93%) at the U.S. Sheep Experiment Station (Dubois, Idaho), in spite of efforts to reduce the possibility for iatrogenic transmission there, suggesting high levels of tick-borne transmission.
Sensitive detection of Escherichia coli O157:H7 based on cascade signal amplification in ELISA.
Shan, Shan; Liu, Daofeng; Guo, Qi; Wu, Songsong; Chen, Rui; Luo, Kai; Hu, Liming; Xiong, Yonghua; Lai, Weihua
2016-09-01
In this study, cascade signal amplification in ELISA involving double-antibody sandwich ELISA and indirectly competitive ELISA was established to sensitively detect Escherichia coli O157:H7. In the double-antibody sandwich ELISA, a complex was formed comprising anti-E. coli O157:H7 polyclonal antibody, E. coli O157:H7, biotinylated anti-E. coli O157:H7 monoclonal antibody, streptavidin, and biotinylated β-lactamase. Penicillin solution was then added into the ELISA well and hydrolyzed by β-lactamase. Afterward, the penicillin solution was transferred to indirectly competitive ELISA. The concentration of penicillin can be sensitively detected in indirectly competitive ELISA. In the cascade signal amplification system, increasing the amount of added E. coli O157:H7 resulted in more β-lactamase and less penicillin. The detection sensitivity of E. coli O157:H7, which was 20cfu/mL with the cascade signal amplification in ELISA, was 1,000-fold higher than that of traditional ELISA. Furthermore, the novel method can be used to detect E. coli O157:H7 in milk (2cfu/g). Therefore, this new signaling strategy will facilitate analyses of highly sensitive foodborne pathogens. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Dark SU (N ) glueball stars on fluid branes
NASA Astrophysics Data System (ADS)
da Rocha, Roldão
2017-06-01
The glueball dark matter, in the pure SU (N ) Yang-Mills theory, engenders dark SU (N ) stars that comprise self-gravitating compact configurations of scalar glueball fields. Corrections to the highest frequency of gravitational wave radiation emitted by dark SU (N ) star mergers on a fluid brane with variable tension, implemented by the minimal geometric deformation, are derived, and their consequences are analyzed. Hence, dark SU (N ) star mergers on a fluid braneworld are shown to be better detectable by the LIGO and the eLISA experiments.
Erickson, J Alan; Grenache, David G
2016-01-15
Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.
Quantification of 2,4-dichlorophenoxyacetic acid in oranges and mandarins by chemiluminescent ELISA.
Vdovenko, Marina M; Stepanova, Alexandra S; Eremin, Sergei A; Van Cuong, Nguyen; Uskova, Natalia A; Yu Sakharov, Ivan
2013-11-15
Direct competitive enzyme-linked immunosorbent assay (ELISA) for 2,4-dichlorophenoxyacetic acid (2,4-D) was developed. Varying the concentrations of monoclonal anti-2,4-D-antibody and the conjugate of soybean peroxidase and 2,4-D the conditions of ELISA performance were optimised. The chemiluminescent method based on peroxidase-catalysed oxidation of luminol was applied to measure the enzyme activity of the conjugate. A mixture of 3-(10'-phenothiazinyl)propane-1-sulfonate and 4-morpholinopyridine was used as potent enhancer of chemiluminescence signal. It was shown that the values of the lower detection limit, IC50 and the working range were 1.5, 64.0, and 6.5-545ng/mL, respectively. The recovery values of CL-ELISA from 10 spiked samples of oranges (n=5) and mandarins (n=5) cultivated in green house without use of 2,4-D and containing different 2,4-D concentrations (10-300ng/mL) were ranged from 92% to 104% that indicated on the absence of matrix effect for the fruit extracts of interest. Determination of 2,4-D in peel of five oranges and five mandarins purchased from stores in Vietnam showed that 2,4-D content in oranges fruits (79-104μg/kg) was significantly higher than that in mandarins (1.66-2.82μg/kg). Copyright © 2013 Elsevier Ltd. All rights reserved.
Wawegama, Nadeeka K.; Kanci, Anna; Marenda, Marc S.; Markham, Philip F.
2014-01-01
Mycoplasma bovis causes a range of diseases in cattle, including mastitis, arthritis, and pneumonia. However, accurate serological diagnosis of infection remains problematic. The studies described here aimed to identify an antigen that might be used to develop a more specific and sensitive diagnostic assay. A 226-kDa immunogenic protein was consistently detected in Western blots by antibodies in sera from calves experimentally infected with M. bovis. This protein was shown to be a membrane protein with lipase activity and was named mycoplasma immunogenic lipase A (MilA). Different regions of MilA were expressed in Escherichia coli as glutathione S-transferase (GST) fusion proteins and recombinant products from the amino-terminal end shown to have strong immunoreactivity with M. bovis-specific bovine sera. The most immunoreactive fusion protein, GST-MilA-ab, was used to develop indirect IgM and IgG enzyme-linked immunosorbent assays (ELISAs). The IgM ELISA detected M. bovis-specific IgM antibody 2 weeks after infection with 97.1% sensitivity and had a specificity of 63.3%, while the IgG ELISA detected M. bovis-specific IgG 3 weeks after infection with 92.86% sensitivity and had a specificity of 98.7%, demonstrating that the IgG ELISA has potential for use as a sensitive and specific assay for detecting infection in cattle. PMID:24334686
Park, Se Jin; Han, Sung Sik; Anvarov, Khikmat; Khajibaev, Abdukhakim; Choi, Min-Ho; Hong, Sung-Tae
2015-12-01
Cystic echinococcosis (CE) is one of the most widespread zoonotic helminthiases, which can last an asymptomatic infection for several years. The purpose of this study was to demonstrate serum antibody prevalence of CE among asymptomatic people in Uzbekistan using ELISA. A total of 2,547 serum samples were collected, 66 from confirmed CE patients and 2,481 of patients with other diseases than CE at a hospital in Tashkent, Uzbekistan. The serum samples were screened for CE specific IgG antibodies by ELISA using cystic fluid antigen obtained from sheep. The serum antibody positive rate was 89.4% (59/66) in CE and 3.6% (89/2,481) in other disease patients. The present ELISA recognized 89.4% sensitivity and 96.4% specificity. The ELISA absorbance of positive samples was distributed 0.271-0.971 for CE and 0.273-0.887 for other disease patients. The other disease patients with high absorbance over 0.3 were 50 (2.0%) who were presumed to be active CE patients. The patients in their 40s showed the highest positive rate of 5.2% (P=0.181), and women were 4.4% while men were 3.1% positive (P=0.136). The data confirmed that there are many asymptomatic patients of CE in Tashkent. It is indicated that CE is an endemic disease of public health importance in Uzbekistan.
Development of Prototype Filovirus Recombinant Antigen Immunoassays
Boisen, Matt L.; Oottamasathien, Darin; Jones, Abigail B.; Millett, Molly M.; Nelson, Diana S.; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shun-ichiro; Hartnett, Jessica N.; Rowland, Megan M.; Heinrich, Megan L.; Akdag, Marjan; Goba, Augustine; Momoh, Mambu; Fullah, Mohammed; Baimba, Francis; Gbakie, Michael; Safa, Sadiki; Fonnie, Richard; Kanneh, Lansana; Cross, Robert W.; Geisbert, Joan B.; Geisbert, Thomas W.; Kulakosky, Peter C.; Grant, Donald S.; Shaffer, Jeffery G.; Schieffelin, John S.; Wilson, Russell B.; Saphire, Erica Ollmann; Branco, Luis M.; Garry, Robert F.; Khan, S. Humarr; Pitts, Kelly R.
2015-01-01
Background. Throughout the 2014–2015 Ebola outbreak in West Africa, major gaps were exposed in the availability of validated rapid diagnostic platforms, protective vaccines, and effective therapeutic agents. These gaps potentiated the development of prototype rapid lateral flow immunodiagnostic (LFI) assays that are true point-of-contact platforms, for the detection of active Ebola infections in small blood samples. Methods. Recombinant Ebola and Marburg virus matrix VP40 and glycoprotein (GP) antigens were used to derive a panel of monoclonal and polyclonal antibodies. Antibodies were tested using a multivariate approach to identify antibody-antigen combinations suitable for enzyme-linked immunosorbent assay (ELISA) and LFI assay development. Results. Polyclonal antibodies generated in goats were superior reagents for capture and detection of recombinant VP40 in test sample matrices. These antibodies were optimized for use in antigen-capture ELISA and LFI assay platforms. Prototype immunoglobulin M (IgM)/immunoglobulin G (IgG) ELISAs were similarly developed that specifically detect Ebola virus–specific antibodies in the serum of experimentally infected nonhuman primates and in blood samples obtained from patients with Ebola from Sierra Leone. Conclusions. The prototype recombinant Ebola LFI assays developed in these studies have sensitivities that are useful for clinical diagnosis of acute ebolavirus infections. The antigen-capture and IgM/IgG ELISAs provide additional confirmatory assay platforms for detecting VP40 and other ebolavirus-specific immunoglobulins. PMID:26232440
Nording, Malin; Denison, Michael S.; Baston, David; Persson, Ylva; Spinnel, Erik; Haglund, Peter
2010-01-01
The chemically activated luciferase expression assay, the chemically activated fluorescence expression assay, and the enzyme-linked immunosorbent assay (ELISA) are all bioanalytical methods that have been used for the detection and quantification of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). However, no comparisons of the results obtained by these three methods have been published analyzing identical replicates of purified sample extracts. Therefore, we have evaluated the performance of each of these methods for analyzing PCDD/Fs in aliquots of extracts from aged-contaminated soil samples and compared the results with those obtained by gas chromatography/high-resolution mass spectrometry (GC/HRMS). The quantitative performance was assessed and the effects of sample purification and data interpretation on the quality of the bioassay results were investigated. Results from the bioanalytical techniques were, in principle, not significantly different from each other or from the GC/HRMS data (p = 0.05). Furthermore, properly used, all of the bioanalytical techniques examined were found to be sufficiently sensitive, selective, and accurate to be used in connection with soil remediation activities when aiming at the remediation goal recommended by the U.S. Environmental Protection Agency (i.e., < 1,000 pg toxic equivalency/g). However, a site-specific correction factor should be applied with the use of the ELISA to account for differences between the toxic equivalency factors and the ELISA cross-reactivities of the various PCDD/F congeners, which otherwise might significantly underestimate the PCDD/F content. PMID:17571676
Test/QA Plan for Verification of Microcystin Test Kits
Microcystin test kits are used to quantitatively measure total microcystin in recreational waters. These test kits are based on enzyme-linked immunosorbent assays (ELISA) with antibodies that bind specifically to microcystins or phosphate activity inhibition where the phosphatas...
Effect of chlorination by-products on the quantitation of microcystins in finished drinking water.
Rosenblum, Laura; Zaffiro, Alan; Adams, William A; Wendelken, Steven C
2017-11-01
Microcystins are toxic peptides that can be produced by cyanobacteria in harmful algal blooms (HABs). Various analytical techniques have been developed to quantify microcystins in drinking water, including liquid chromatography tandem mass spectrometry (LC/MS/MS), enzyme linked immunosorbent assay (ELISA), and oxidative cleavage to produce 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) with detection by LC/MS/MS, the "MMPB method". Both the ELISA and MMPB methods quantify microcystins by detecting a portion of the molecule common to most microcystins. However, there is little research evaluating the effect of microcystin chlorination by-products potentially produced during drinking water treatment on analytical results. To evaluate this potential, chlorinated drinking water samples were fortified with various microcystin congeners in bench-scale studies. The samples were allowed to react, followed by a comparison of microcystin concentrations measured using the three methods. The congener-specific LC/MS/MS method selectively quantified microcystins and was not affected by the presence of chlorination by-products. The ELISA results were similar to those obtained by LC/MS/MS for most microcystin congeners, but results deviated for a particular microcystin containing a variable amino acid susceptible to oxidation. The concentrations measured by the MMPB method were at least five-fold higher than the concentrations of microcystin measured by the other methods and demonstrate that detection of MMPB does not necessarily correlate to intact microcystin toxins in finished drinking water. Published by Elsevier Ltd.
Paiva, Philipp Ricardo S O; Grego, Kathleen F; Lima, Valéria M F; Nakamura, Alex A; da Silva, Deuvânia C; Meireles, Marcelo V
2013-11-15
Infection by Cryptosporidium serpentis is one of the most important diseases in reptiles and is characterized by chronic clinical or subclinical infection and the presence of hypertrophic gastritis, food regurgitation, progressive weight loss, mortality, and intermittent or continuous shedding of oocysts in the feces. The objectives of this study were to standardize an indirect enzyme-linked immunosorbent assay (ELISA) to detect antibodies against C. serpentis and to evaluate the clinical, parasitological, and humoral immune response in snakes naturally infected with C. serpentis. Twenty-one snakes naturally infected with C. serpentis and housed at the Butantan Institute, São Paulo, Brazil, underwent clinical and parasitological analyses for C. serpentis infection through daily records of clinical signs and a monthly survey of fecal shedding of oocysts using the Kinyoun's acid-fast staining. The serological evaluation was performed monthly by indirect ELISA using crude total antigen from oocysts of C. serpentis to detect anti-C. serpentis antibodies. Clinical symptoms consisted of food regurgitation, inappetence, and progressive weight loss. The parasitological analysis revealed intermittent fecal shedding of a variable number of oocysts in all snakes, with positivity in 85.32% (157/184) of the samples. The indirect ELISA was positive in 68.25% (86/126) of the samples. A humoral immune response was observed in most animals; however, fluctuating antibodies levels, leading to alternating positive and negative results, were observed in most snakes. Copyright © 2013 Elsevier B.V. All rights reserved.
A Novel Blocking ELISA for Detection of Antibodies against Hepatitis E Virus in Domestic Pigs.
Chen, Yiyang; Zhao, Qin; Liu, Baoyuan; Wang, Lizhen; Sun, Yani; Li, Huixia; Wang, Xinjie; Syed, Shahid Faraz; Zhang, Gaiping; Zhou, En-Min
2016-01-01
Hepatitis E virus (HEV) infects both humans and animals, with an overall human mortality rate generally less than 1%, but as high as 20% among pregnant women. HEV strains fall into 4 major genotypes. Zoonotic genotypes 3 and 4 associate with sporadic human and animal HEV cases in many industrialized countries. To date, collective evidence implicates pigs as the main HEV reservoir, justifying the importance of monitoring HEV infection rates in pig herds to prevent human illness. Due to the lack of a robust in vitro cell culture system for viral propagation, no "gold standard" assay has yet been developed to detect HEV infection in domestic pigs. 1E4, a monoclonal antibody (mAb) specific for the C-terminal 268 amino acids of HEV genotype 4 ORF2 capsid protein (sORF2-C), was generated and conjugated to horseradish peroxidase (HRP) for use in a blocking ELISA (bELISA). Optimal sORF2-C coating antigen concentration (8 μg/ml), HRP-1E4 dilution (1:1000), and test pig serum dilution (1:20) were determined using a checkerboard titration test. A cut-off value of 16.9% was chosen to differentiate between positive vs. negative sera after mean percent inhibition (PI) testing of 230 negative pig sera. Compared with the indirect ELISA (iELISA), western blot, and a commercial ELISA kit for detecting anti-HEV antibodies in human sera, the bELISA showed no statistical differences and statistically high coincidence of 93.23%, 92%, and 95% with the other tests, respectively. A blocking ELISA (bELISA) for detecting anti-HEV antibodies in pig serum samples was developed with high sensitivity and high specificity comparable to that of the indirect ELISA. The bELISA results exhibited high agreement with iELISA, western blot, and a commercial ELISA kit designed to detect human anti-HEV antibodies. Therefore, bELISA should serve as an ideal method for large-scale serological investigation of anti-HEV antibodies in domestic pigs.
Familial associations with paratuberculosis ELISA results in Texas Longhorn cattle.
Osterstock, Jason B; Fosgate, Geoffrey T; Cohen, Noah D; Derr, James N; Manning, Elizabeth J B; Collins, Michael T; Roussel, Allen J
2008-05-25
The objective of this cross-sectional study was to estimate familial associations with paratuberculosis ELISA status in beef cattle. Texas Longhorn cattle (n=715) greater than 2years of age were sampled for paratuberculosis testing using ELISA and fecal culture. Diagnostic test results were indicative of substantial numbers of false-positive serological reactions consistent with environmental exposure to non-MAP Mycobacterium spp. Associations between ancestors and paratuberculosis ELISA status of offspring were assessed using conditional logistic regression. The association between ELISA status of the dam and her offspring was assessed using linear mixed-effect models. Significant associations were identified between some ancestors and offspring ELISA status. The odds of being classified as "suspect" or greater based on ELISA results were 4.6 times greater for offspring of dams with similarly increased S:P ratios. A significant positive linear association was also observed between dam and offspring log-transformed S:P ratios. Results indicate that there is familial aggregation of paratuberculosis ELISA results in beef cattle and suggest that genetic selection based on paratuberculosis ELISA status may decrease seroprevalence. However, genetic selection may have minimal effect on paratuberculosis control in herds with exposure to non-MAP Mycobacterium spp.
Coty, Jean-Baptiste; Noiray, Magali; Vauthier, Christine
2018-04-26
A Surface Plasmon Resonance chip (SPR) was developed to study the activation of complement system triggered by nanomaterials in contact with human serum, which is an important concern today to warrant safety of nanomedicines. The developed chip was tested for its specificity in complex medium and its longevity of use. It was then employed to assess the release of complement fragments upon incubation of nanoparticles in serum. A comparison was made with other current methods assessing complement activation (μC-IE, ELISA). The SPR chip was found to give a consistent response for C3a release upon activation by nanoparticles. Results were similar to those obtained by μC-IE. However, ELISA detection of iC3b fragments showed an explained high non-specific background. The impact of sample preparation preceding the analysis was assessed with the newly develop SPR method. The removal of nanoparticles before analysis showed an important modification in the obtained response, possibly leading to false negative results. The SPR chip developed in this work allows for an automated assessment of complement activation triggered by nanoparticles with possibility of multiplexed analysis. The design of the chip proved to give consistent results of complement activation by nanoparticles.
Huang, F-M; Chen, Y-J; Chou, M-Y; Chang, Y-C
2005-12-01
To investigate the tissue type plasminogen activator (t-PA) activity in human pulp cells stimulated with Porphyromonas endodontalis (P. endodontalis) in the absence or presence of p38 inhibitor SB203580, mitogen-activated protein kinase kinase (MEK) inhibitor U0126 and phosphatidylinositaol 3-kinase (PI3K) inhibitor LY294002. The supernatants of P. endodontalis were used to evaluate t-PA activity in human pulp cells using casein zymography and enzyme-linked immunosorbent assay (ELISA). Furthermore, to search for possible signal transduction pathways, SB203580, U0126 and LY294002 were added to test how they modulated the t-PA activity. The main casein secreted by human pulp cells migrated at 70 kDa and represented t-PA. Secretion of t-PA was found to be stimulated with P. endodontalis during 2-day cultured period (P < 0.05). From the results of casein zymography and ELISA, SB203580 and U0126 significantly reduced the P. endodontalis stimulated t-PA production respectively (P < 0.05). However, LY294002 lacked the ability to change the P. endodontalis stimulated t-PA production (P > 0.05). Porphyromonas endodontalis enhances t-PA production in human pulp cells, and the signal transduction pathways p38 and MEK are involved in the inhibition of t-PA.
Allergen immunoassays--considerations for use of naturally incurred standards.
Taylor, Steve L; Nordlee, Julie A; Niemann, Lynn M; Lambrecht, Debra M
2009-09-01
The enzyme-linked immunosorbent assay (ELISA) offers many advantages for the detection of potentially hazardous allergenic food residues that might become adventitious components of other foods during the course of food production and processing. ELISAs detect proteins, and food allergens are proteins. ELISAs are sufficiently sensitive and specific for detection of food allergen residues. ELISAs can also be produced in formats that are compatible with the industrial food processing environment. However, ELISAs also have disadvantages that should be carefully evaluated and widely recognized. Various food-processing operations can have profound effects on the detectability of allergenic food residues. ELISAs detect intact proteins but protein hydrolysates evade detection in some ELISA formats. The residual proteins present in some ingredients derived from commonly allergenic sources may also not be easily detected with ELISAs because of the nature of the protein residues remaining, e.g. lipophilic. Processing operations can dramatically lower the solubility of proteins. In some food formulations, heat processing, in particular, induces chemical modifications that can affect antibody binding to epitopes in the ELISA. The use of naturally incurred standards where allergenic food residues are incorporated into various representative food matrices and then processed in a manner similar to "real-world" food processing can reveal some of the limitations of allergen ELISAs. Methods for the preparation of naturally incurred standards in chocolate, cookie, muffin, ice cream, pasta, frankfurter, and cream of potato soup are provided as examples.
Tong, Qing-He; Tao, Tao; Xie, Li-Qi; Lu, Hao-Jie
2016-06-15
Detection of low-abundance proteins and their post-translational modifications (PTMs) remains a great challenge. A conventional enzyme-linked immunosorbent assay (ELISA) is not sensitive enough to detect low-abundance PTMs and suffers from nonspecific detection. Herein, a rapid, highly sensitive and specific platform integrating ELISA with a proximity ligation assay (PLA), termed ELISA-PLA, was developed. Using ELISA-PLA, the specificity was improved by the simultaneous and proximate recognition of targets through multiple probes, and the sensitivity was significantly improved by rolling circle amplification (RCA). For GFP, the limit of detection (LOD) was decreased by two orders of magnitude compared to that of ELISA. Using site-specific phospho-antibody and pan-specific phospho-antibody, ELISA-PLA was successfully applied to quantify the phosphorylation dynamics of ERK1/2 and the overall tyrosine phosphorylation level of ERK1/2, respectively. ELISA-PLA was also used to quantify the O-GlcNAcylation of AKT, c-Fos, CREB and STAT3, which is faster and more sensitive than the conventional immunoprecipitation and western blotting (IP-WB) method. As a result, the sample consumption of ELISA-PLA was reduced 40-fold compared to IP-WB. Therefore, ELISA-PLA could be a promising platform for the rapid, sensitive and specific detection of proteins and PTMs. Copyright © 2016 Elsevier B.V. All rights reserved.
Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O
2014-06-01
Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.
Yang, Shunli; Shang, Youjun; Yin, Shuanghui; Tian, Hong; Chen, Yan; Sun, Shiqi; Jin, Ye; Liu, Xiangtao
2014-07-15
Single-domain variable heavy chain (VHH) antibody fragments are derived from heavy-chain antibodies of Camelids. Their comparatively small size, solubility, high affinity and specificity to the targets antigen make them suitable for many biotechnological applications. In this study, a VHH library was constructed from porcine circovirus type 2 (PCV2) vaccine immunized C. bactrianus and three VHH fragments specific to the capsid protein of PCV2 (PCV2 Cap) were selected and characterized. The selected VHH clones (VHH-c1/c3/c4) were stably expressed as soluble protein in E. coli, and were specific to PCV2 Cap except VHH-c3 which shows binding activity with both PCV1 and PCV2 Cap by ELISA. All the VHH-cs show high association rate constant and dissociation rate constant, which was 1.84 × 10(5)M(-1)s(-1), 9.00 × 10(-3)s(-1) for VHH-c1, 5.49 × 10(4)M(-1)s(-1), 9.91 × 10(-3)s(-1) and 1.46 × 10(5)M(-1)s(-1), 1.18 × 10(-3)s(-1) for VHH-c3 and VHH-c4 assessed by surface plasmon resonance (SPR). Additionally, the selected three VHH-cs can bind to different epitopes of PCV2 Cap that was determined by additive ELISA. Our study confirmed that VHHs with high affinity and specificity to PCV2 Cap can be selected from an immune VHH library, and have the potential application for effective and fast diagnostic development of PCV2. Copyright © 2014 Elsevier B.V. All rights reserved.
Yu, Bing; Ni, Ming; Li, Wen-Han; Lei, Ping; Xing, Wei; Xiao, Dai-Wen; Huang, Yu; Tang, Zhen-Jie; Zhu, Hui-Fen; Shen, Guan-Xin
2005-07-14
To identify the scFv antibody fragments specific for hepatocellular carcinoma by biopanning from a large human naive scFv phage display library. A large human naive scFv phage library was used to search for the specific targets by biopanning with the hepatocellular carcinoma cell line HepG2 for the positive-selecting and the normal liver cell line L02 for the counter-selecting. After three rounds of biopanning, individual scFv phages binding selectively to HepG2 cells were picked out. PCR was carried out for identification of the clones containing scFv gene sequence. The specific scFv phages were selected by ELISA and flow cytometry. DNA sequences of positive clones were analyzed by using Applied Biosystem Automated DNA sequencers 3 730. The expression proteins of the specific scFv antibody fragments in E.coli HB2151 were purified by the affinity chromatography and detected by SDS-PAGE, Western blot and ELISA. The biological effect of the soluble antibody fragments on the HepG2 cells was investigated by observing the cell proliferation. Two different positive clones were obtained and the functional variable sequences were identified. Their DNA sequences of the scFv antibody fragments were submitted to GenBank (accession nos: AY686498 and AY686499). The soluble scFv antibody fragments were successfully expressed in E.coli HB2151. The relative molecular mass of the expression products was about 36 ku, according to its predicted M(r) value. The two soluble scFv antibody fragments also had specific binding activity and obvious growth inhibition properties to HepG2 cells. The phage library biopanning permits identification of specific antibody fragments for hepatocellular carcinoma and affords experiment evidence for its immunotherapy study.
Iddawela, D; Ehambaram, K; Kumarasiri, P V; Wijesundera, S
2015-09-01
ELISA is the most widely used form of diagnosis for toxoplasmosis. Several commercial kits are currently used in Sri Lanka. However, these kits are not affordable in resource-limited settings. Objectives Aim of this study was to develop a cost effective in-house ELISA for the detection of Toxoplasma antibody and to estimate the diagnostic accuracy compared to a commercial kit. Vero cell lines were inoculated with tachyzoites and harvested after 2-6 days and sonicated to obtain somatic antigen. The antigen was used as coating material in ELISA to detect antibodies against T. gondii in patient sera. Hundred and three patients' sera were analysed by in-house ELISA and kit ELISA. Optical density (OD) values were analysed statistically. Toxoplasma IgG avidity test was used to determine the chronic and acute phase of infection. The optimum working dilutions for antigen was 0.846 μg/ml and for serum 1 in 100. The optimal cut-off values for the in-house ELISA within the range 0.85 to 0.98 at which the sensitivity was 95.3% and specificity was 98.3. The OD values of in-house ELISA were compared with OD values of kit ELISA and the results showed strong correlation between the two tests. The results of our study demonstrated that our in-house ELISA for detection of T. gondii antibody was as sensitive and specific as the commercial kit used in this study. Thus, the in-house ELISA is a useful, costeffective tool for diagnostic and screening purposes.
Lobatón, Triana; López-García, Alicia; Rodríguez-Moranta, Francisco; Ruiz, Alexandra; Rodríguez, Lorena; Guardiola, Jordi
2013-12-01
Fecal calprotectin (FC), as determined by the enzyme-linked immunoassay (ELISA) test, has been proposed as a promising biomarker of endoscopic activity in Crohn's disease (CD). However data on its accuracy in predicting endoscopic remission according to location and postoperative recurrence (POR) is scarce. Our objective was to evaluate the ability of FC determined by a new quantitative point-of-care test (FC-QPOCT) to predict endoscopic remission and POR in CD patients. FC was determined simultaneously by an enzyme-linked immunoassay test (FC-ELISA) and a FC-QPOCT in CD patients undergoing colonoscopy. Clinical disease activity was assessed according to the Crohn's Disease Activity Index (CDAI). Endoscopic results were assessed according to the Crohn's Disease Endoscopic Activity Index of Severity (CDEIS) and postoperative recurrence according to the Rutgeerts' score. A total of 115 ileocolonoscopies were performed (29 on patients with ileocolonic resection). FC levels correlated more closely with the CDEIS than leucocytes, platelets or CRP. The prediction of "endoscopic remission" (CDEIS<3), using FC-QPOCT (cut-off 272 μg/g) and FC-ELISA (cut-off 274 μg/g) presented an AUC of 0.933 and 0.935 respectively. FC-QPOCT results correlated better with endoscopic activity in the ileocolonic location (Pearson's correlation, r=0.879; P<0.001), than the colonic (r=0.725; P<0.001) or the ileal location (r=0.437; P=0.016). Median FC-QPOCT levels discriminated Rutgeerts' score i0-i1 from i2-i4 (98 (range 30-306) μg/g vs. 234.5 (range 100-612) μg/g respectively, P=0.012). FC determined by rapid quantitative test predicts "endoscopic remission" and endoscopic postoperative recurrence in CD patients. Copyright © 2013 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Bowers, Erin; Hellmich, Richard; Munkvold, Gary
2014-07-09
Field trials were conducted from 2007 to 2010 to compare grain fumonisin levels among non-Bt maize hybrids and Bt hybrids with transgenic protection against manual infestations of European corn borer (ECB) and Western bean cutworm (WBC). HPLC and ELISA were used to measure fumonisin levels. Results of the methods were highly correlated, but ELISA estimates were higher. Bt hybrids experienced less insect injury, Fusarium ear rot, and fumonisin contamination compared to non-Bt hybrids. WBC infestation increased fumonisin content compared to natural infestation in non-Bt and hybrids expressing Cry1Ab protein in five of eight possible comparisons; in Cry1F hybrids, WBC did not impact fumonisins. These results indicate that WBC is capable of increasing fumonisin levels in maize. Under WBC infestation, Cry1F mitigated this risk more consistently than Cry1Ab or non-Bt hybrids. Transgenically expressed Bt proteins active against multiple lepidopteran pests can provide broad, consistent reductions in the risk of fumonisin contamination.
[Extraction method suitable for detection of unheated crustaceans including cephalothorax by ELISA].
Shibahara, Yusuke; Yamada, Itta; Uesaka, Yoshihiko; Uneo, Noriko; Abe, Akihisa; Ohashi, Eiji; Shiomi, Kazuo
2009-08-01
When unheated whole samples of crustaceans (shrimp, prawn and crab) were analyzed with our ELISA kit (FA test EIA-Crustacean 'Nissui') using anti-tropomyosin antibodies, a remarkable reduction in reactivity was recognized. This reduction in activity was found to be due to the digestion of tropomyosin during the extraction process by proteases contained in cephalothorax. To avoid the digestion of tropomyosin by proteases, we developed an extraction method (heating method) suitable for the detection of tropomyosin in unheated crustaceans including cephalothorax. Experiments with unheated whole samples of various species of crustaceans confirmed that the heating method greatly improved the low reactivity in the standard method; the heating method gave extraction efficiencies of as high as 93-107%. Various processed crustaceans with cephalothorax, such as dry products (unheated or weakly heated products) and pickles in soy sauce (unheated products), that showed low reactivity with the standard method were confirmed to give superior results with the heating method. These results indicated that the developed heating method is suitable for detecting unheated crustaceans with cephalothorax by means of the ELISA kit.
Beaver, A; Sweeney, R W; Hovingh, E; Wolfgang, D R; Gröhn, Y T; Schukken, Y H
2017-09-01
Mycobacterium avium ssp. paratuberculosis (MAP), the causative agent of ruminant Johne's disease, presents a particular challenge with regard to infection mitigation on dairy farms. Diagnostic testing strategies to identify and quantify MAP and associated antibodies are imperfect, and certain facets of the relationship between diagnostic tests remain to be explored. Additional repeated-measures data from known infected animals are needed to complement the body of cross-sectional research on Johne's disease-testing methods. Statistical models that accurately account for multiple diagnostic results while adjusting for the effects of individual animals and herds over time can provide a more detailed understanding of the interplay between diagnostic outcomes. Further, test results may be considered as continuous wherever possible so as to avoid the information loss associated with dichotomization. To achieve a broader understanding of the relationship between diagnostic tests, we collected a large number of repeated fecal and milk samples from 14 infected cows, in addition to bulk milk samples, from 2 low-prevalence dairy herds in the northeast United States. Predominately through the use of mixed linear modeling, we identified strong associations between milk ELISA optical density, fecal quantitative PCR, and fecal culture in individual animals while concurrently adjusting for variables that could alter these relationships. Notably, we uncovered subtleties in the predictive abilities of fecal shedding level on milk ELISA results, with animals categorized as disease progressors reaching higher ELISA optical density levels. Moreover, we observed that spikes in fecal shedding could predict subsequent high ELISA values up to 2 mo later. We also investigated the presence of MAP in individual milk samples via PCR and noted an association between poor udder hygiene and MAP positivity in milk, suggesting some level of environmental contamination. The paucity of positive milk samples and the complete absence of detectable MAP in the bulk tank throughout the study period indicate that contamination of milk with MAP may not be of chief concern in low-prevalence herds. An enhanced understanding of the interrelationships between diagnostic tests can only benefit the development of testing strategies and objectives, which in turn may lessen MAP infection prevalence in dairy herds. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
2012-01-01
Background Animal disease monitoring and surveillance are crucial for ensuring the health of animals, humans and the environment. Many studies have investigated the utility of monitoring syndromes associated with data from veterinary laboratory submissions, but no research has focused on how negative test results from a veterinary diagnostic laboratory data can be used to improve our knowledge of disease outbreaks. For example, if a diagnostic laboratory was seeing a disproportionate number of negative test results for a known disease could this information be an indication of a novel disease outbreak? The objective of this study was to determine the association between the porcine circovirus associated disease (PCVAD) outbreak in Ontario 2004–2006 and the results of porcine reproductive and respiratory syndrome virus (PPRSV) enzyme-linked immunosorbent assay (ELISA) and the results of PRRSV polymerase chain reaction (PCR) diagnostic tests requested by veterinarians. Results Retrospective data were collected from the Animal Health Laboratory (AHL) at the University of Guelph, Guelph, Ontario Canada and were comprised of weekly counts of PRRSV ELISA and PRRSV PCR diagnostic tests requested by swine practitioners from 2000–2007. The results of the PRRSV ELISA and PRRSV PCRs were analysed separately in two models using logistic regression with the dependent variables being: the weekly probability of PRRSV ELISA positivity, and the weekly probability of PRRSV PCR positivity, respectively. The weekly probability of PRRSV PCR positivity decreased during the PVCAD outbreak (OR=0.66, P=0.01). The weekly probability of PRRSV ELISA positivity was not associated with the PCVAD outbreak. Conclusions The results of this study showed that during the PCVAD outbreak in Ontario from December 2004-May 2006, the probability of a positive PRRSV PCR at the AHL decreased. We conclude that when a decrease in test positivity occurs for a known disease, it may suggest that a new disease agent is emerging in the population. Hence, monitoring the test results of commonly used first-order tests for a known disease (e.g. PRRSV) has the potential to be a unique form of syndromic data for the timely identification of novel disease outbreaks in swine populations. PMID:23072647
Meza-Lucas, Antonio; Pérez-Villagómez, María-Fernanda; Martínez-López, José-Patricio; García-Rodea, Ricardo; Martínez-Castelán, María-Guadalupe; Escobar-Gutiérrez, Alejandro; de-la-Rosa-Arana, Jorge-Luis; Villanueva-Zamudio, Altagracia
2016-09-01
A comparison of DOT-ELISA and Standard-ELISA was made for detection of Vibrio cholerae toxin in culture supernatants of bacteria isolated from human and environmental samples. A total of 293 supernatants were tested in a double blind assay. A correlation of 100 % was obtained between both techniques. The cholera toxin was found in 20 Inaba and 3 Ogawa strains. Positive samples were from seafood (17 samples), potable water (1 sample) and sewage (5 samples). The DOT-ELISA was useful as the standard-ELISA to confirm the presence of cholera toxin in the environmental samples.
Figueroa-Santiago, Olgary; Delgado, Bonnibel; Espino, Ana M.
2011-01-01
An indirect enzyme-linked immunosorbent assay (ELISA) was developed and evaluated for its diagnostic ability to detect human IgG antibodies against Fasciola hepatica saposin-like protein-2. The assay was compared with an indirect ELISA with excretory-secretory products (FhES) from adult F. hepatica. In an analysis of the sera of 37 patients infected with F. hepatica, 40 patients with other parasitic infections, and 50 healthy controls, the sensitivity of both ELISA assays was 100%. However, the FhSAP2-based ELISA was more specific (95.6%) than the FhES-ELISA (91.9%). These results demonstrated that FhSAP2 can be used in the serodiagnosis of chronic human fascioliasis with additional advantage that is relative cheap and easy to produce. Studies are in progress to evaluate this FhSAP2-ELISA assay in a large-scale prevalence surveys in endemic areas. PMID:21683266
Cheng, Kai-Chun; Wu, Yu-Jen; Cheng, Kai-Hung; Cheng, Kai-Yuan; Chen, Kuo-Jen; Wu, Wen-Chuan; Lee, Po-Yen; Chang, Cheng-Hsien
2018-06-01
This study surveyed the novel autoantigens expressed in the orbital fat tissue of patients with Graves' orbitopathy (GO) and explored the possibility of the autoantibodies against novel autoantigens as biomarkers for GO. We used immuno-proteomic methods to survey novel autoantigens expressed in the orbit fat tissue of GO patients and confirmed by enzyme-linked immunosorbent assay (ELISA). One protein spot (aldehyde dehydrogenase 2 (ALDH2)) revealed high reactivity with the GO serum than did the healthy control serum and was further verified by ELISA. We found that the plasma anti-ALDH2 antibody level was increased in GO patients compared to healthy control donors. In addition, anti-ALDH2 antibody level was correlated with GO activity classified by clinical activity score(r = 0.588, p < 0.001, using Pearson's correlation). These increased levels of anti-ALDH2 antibody in GO serum suggested that ALDH2 could attribute target autoantigen in GO, and anti-ALDH2 autoantibody might serve as a biomarker for GO and help to predict disease activity.
Nonaminoglycoside compounds induce readthrough of nonsense mutations
Damoiseaux, Robert; Nahas, Shareef; Gao, Kun; Hu, Hailiang; Pollard, Julianne M.; Goldstine, Jimena; Jung, Michael E.; Henning, Susanne M.; Bertoni, Carmen
2009-01-01
Large numbers of genetic disorders are caused by nonsense mutations for which compound-induced readthrough of premature termination codons (PTCs) might be exploited as a potential treatment strategy. We have successfully developed a sensitive and quantitative high-throughput screening (HTS) assay, protein transcription/translation (PTT)–enzyme-linked immunosorbent assay (ELISA), for identifying novel PTC-readthrough compounds using ataxia-telangiectasia (A-T) as a genetic disease model. This HTS PTT-ELISA assay is based on a coupled PTT that uses plasmid templates containing prototypic A-T mutated (ATM) mutations for HTS. The assay is luciferase independent. We screened ∼34,000 compounds and identified 12 low-molecular-mass nonaminoglycosides with potential PTC-readthrough activity. From these, two leading compounds consistently induced functional ATM protein in ATM-deficient cells containing disease-causing nonsense mutations, as demonstrated by direct measurement of ATM protein, restored ATM kinase activity, and colony survival assays for cellular radiosensitivity. The two compounds also demonstrated readthrough activity in mdx mouse myotube cells carrying a nonsense mutation and induced significant amounts of dystrophin protein. PMID:19770270
Edupuganti, Soujanya Ratna; Edupuganti, Om Prakash; O'Kennedy, Richard; Defrancq, Eric; Boullanger, Stéphanie
2013-04-01
An affinity purification method that isolates T-2 toxin-specific IgY utilizing a T-2-toxin-immobilized column was developed. The T-2 toxin was covalently coupled via a carbonyldiimidazole-activated hydroxyl functional group to amine-activated sepharose beads. The affinity-purified IgY was characterized by gel electrophoresis, fast protein liquid chromatography, enzyme-linked immunosorbant assay, surface plasmon resonance and mass spectrometry. A competitive inhibition ELISA (CI-ELISA) was performed using affinity-purified IgY with a T-2 toxin detection sensitivity of 30 ng/mL, which falls within the maximum permissible limit of 100 ng/mL. The cross reactivity of IgY towards deoxynivalenol, zearalenone, fumonisin B1 and HT-2 was significantly reduced after affinity purification. A surface plasmon resonance (SPR)-based inhibition assay was also applied for quantitative determination of T-2 toxin in spiked wheat samples. The results obtained indicate the feasibility of utilizing this IgY-based assay for the detection of T-2 toxin in food samples.
Pedersen, Ronnie O; Peters, Tim; Panda, Rakhi; Wehling, Paul; Garber, Eric A E
2017-07-01
A shipment of imported garlic powder was suspected of containing peanut. Samples (subs) collected from the shipment displayed considerable variability in peanut antigenicity when analyzed by enzyme-linked immunosorbent assay (ELISA). This raised questions regarding whether peanut was actually present, the amount present, and the basis for the variability in antigenic content. Analyses that used an xMAP multiplex assay for the detection of peanut and additional food allergens generated responses that were characteristic of peanut. Specifically, the relative intensities of two different peanut-specific antibodies coupled to beads (peanut-37 and -38) and the antigen profiles were identical to garlic controls spiked with peanut. In addition, the xMAP data did not indicate the presence of other allergens. Quantitative analyses indicated an approximately fivefold variation in peanut concentration among different subs. In contrast, within a sub, the apparent peanut concentration appeared constant. Particle size analyses of the garlic powder subs indicated a single distribution profile, with a peak at 380 μm. ELISA analysis of sieve-fractionated garlic powder from one of the subs indicated that slightly less than half of the detectable peanut was smaller than 212 μm, with the remainder almost evenly split between 212 and 300 μm and >300 μm. Modeling to predict possible oral exposure levels of peanut other than those directly measured requires additional research on the physicochemical properties of peanut and garlic, along with information on the production of the garlic powder.
75 FR 57200 - National Poultry Improvement Plan and Auxiliary Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-20
... (ELISA) test to confirm the positive results of other serological tests. We are proposing to remove the ELISA test from this list. The ELISA test is a screening assay and should not be used to confirm... status is negative for Mycoplasma. We would amend this paragraph to include the ELISA and the official...
Pérez-Ruiz, Elena; Decrop, Deborah; Ven, Karen; Tripodi, Lisa; Leirs, Karen; Rosseels, Joelle; van de Wouwer, Marlies; Geukens, Nick; De Vos, Ann; Vanmechelen, Eugeen; Winderickx, Joris; Lammertyn, Jeroen; Spasic, Dragana
2018-07-26
The close correlation between Tau pathology and Alzheimer's disease (AD) progression makes this protein a suitable biomarker for diagnosis and monitoring of the disorder evolution. However, the use of Tau in diagnostics has been hampered, as it currently requires collection of cerebrospinal fluid (CSF), which is an invasive clinical procedure. Although measuring Tau-levels in blood plasma would be favorable, the concentrations are below the detection limit of a conventional ELISA. In this work, we developed a digital ELISA for the quantification of attomolar protein Tau concentrations in both buffer and biological samples. Individual Tau molecules were first captured on the surface of magnetic particles using in-house developed antibodies and subsequently isolated into the femtoliter-sized wells of a 2 × 2 mm 2 microwell array. Combination of high-affinity antibodies, optimal assay conditions and a digital quantification approach resulted in a 24 ± 7 aM limit of detection (LOD) in buffer samples. Additionally, a dynamic range of 6 orders of magnitude was achieved by combining the digital readout with an analogue approach, allowing quantification from attomolar to picomolar levels of Tau using the same platform. This proves the compatibility of the presented assay with the wide range of Tau concentrations encountered in different biological samples. Next, the developed digital assay was applied to detect total Tau levels in spiked blood plasma. A similar LOD (55 ± 29 aM) was obtained compared to the buffer samples, which was 5000-fold more sensitive than commercially available ELISAs and even outperformed previously reported digital assays with 10-fold increase in sensitivity. Finally, the performance of the developed digital ELISA was assessed by quantifying protein Tau in three clinical CSF samples. Here, a high correlation (i.e. Pearson coefficient of 0.99) was found between the measured percentage of active particles and the reference protein Tau values. The presented digital ELISA technology has great capacity in unlocking the potential of Tau as biomarker for early AD diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Lu, Shi-Ying; Zhou, Yu; Li, Yan-Song; Lin, Chao; Meng, Xian-Mei; Yan, Dong-Ming; Li, Zhao-Hui; Yu, Shi-Yu; Liu, Zeng-Shan; Ren, Hong-Lin
2011-08-01
Okadaic acid (OA) and analogues of dinophysistoxin (DTX) are key diarrheic shellfish poisoning (DSP) toxins, which possibly arouse DSP symptoms by consuming the contaminated shellfish. Because of the stable toxicity in high temperature and the long-term carcinogenicity, the outbreaks of DSP related to consumption of bivalve mollusks contaminated by DSP toxins pose a hazard to public health. Therefore, it is worth developing a fast and reliable analytical method for the detection of OA and analogues in shellfish. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ELISA) (icELISA) for detecting OA and DTX-1 in seafood was developed based on monoclonal antibody (McAb). The OA was conjugated to human immunoglobulin G (IgG) and bovine serum albumin (BSA) by the active ester method as the immune antigen and the detective antigen. The spleen cells from BALB/c mice immunized with OA-IgG were fused with SP2/0 myeloma cells. A hybridoma cell line, which secreted McAb against OA, was selected by "limiting dilution" cloning. An icELISA was developed based on immobilized conjugate (OA-BSA) competing the McAb with the free OA in seafood sample. A hybridoma cell line, which secreted IgG1 subclass monoclonal antibody (McAb) against OA, was selected. The IC(50) of the McAb for OA and dinophytoxin-1 (DTX-1) were 4.40 and 3.89 ng/mL, respectively. Based on the McAb, an indirect competitive ELISA for detection of OA and DTX-1 in seafood was developed. The regression equation was y = 54.713x - 25.879 with a coefficient correlation of R (2) = 0.9729. The linear range and the limit of detection were 0.4-12.5 and 0.45 ng/mL, respectively. The average recovery of OA and DTX-1 spiked shellfish was 82.29% with the coefficient of variation of 7.67%. The developed icELISA is a fast, sensitive, and convenient assay for detecting of total amount of OA and DTX-1 in seafood.
Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.
2016-01-01
Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270
Liu, Dan; Li, Xingrui; Zhou, Junkai; Liu, Shibo; Tian, Tian; Song, Yanling; Zhu, Zhi; Zhou, Leiji; Ji, Tianhai; Yang, Chaoyong
2017-10-15
Enzyme-linked immunosorbent assay (ELISA) is a popular laboratory technique for detection of disease-specific protein biomarkers with high specificity and sensitivity. However, ELISA requires labor-intensive and time-consuming procedures with skilled operators and spectroscopic instrumentation. Simplification of the procedures and miniaturization of the devices are crucial for ELISA-based point-of-care (POC) testing in resource-limited settings. Here, we present a fully integrated, instrument-free, low-cost and portable POC platform which integrates the process of ELISA and the distance readout into a single microfluidic chip. Based on manipulation using a permanent magnet, the process is initiated by moving magnetic beads with capture antibody through different aqueous phases containing ELISA reagents to form bead/antibody/antigen/antibody sandwich structure, and finally converts the molecular recognition signal into a highly sensitive distance readout for visual quantitative bioanalysis. Without additional equipment and complicated operations, our integrated ELISA-Chip with distance readout allows ultrasensitive quantitation of disease biomarkers within 2h. The ELISA-Chip method also showed high specificity, good precision and great accuracy. Furthermore, the ELISA-Chip system is highly applicable as a sandwich-based platform for the detection of a variety of protein biomarkers. With the advantages of visual analysis, easy operation, high sensitivity, and low cost, the integrated sample-in-answer-out ELISA-Chip with distance readout shows great potential for quantitative POCT in resource-limited settings. Copyright © 2017. Published by Elsevier B.V.
Interpreting dual ELISA and qPCR data for bacterial kidney disease of salmonids.
Nance, Shelly L; Riederer, Michael; Zubkowski, Tyler; Trudel, Marc; Rhodes, Linda D
2010-09-02
Although there are a variety of methods available for the detection of Renibacterium salmoninarum, the causative agent of bacterial kidney disease in salmon and trout, the enzyme-linked immunosorbent assay (ELISA) is probably the most widely used method. However, ELISA measures bacterial antigen, which does not necessarily reflect the number of cells present. We hypothesized that dual analysis of kidney tissue by ELISA and a quantitative real-time polymerase chain reaction assay (qPCR) would provide complementary information about antigen level and the number of bacterial genomes. We found that DNA extracted from the insoluble fraction of the ELISA tissue preparation produced the same qPCR result as DNA extracted directly from frozen tissue, permitting true dual analysis of the same tissue sample. We examined kidney tissue in this manner from individual free-ranging juvenile Chinook salmon and antibiotic-treated captive subadult Chinook salmon and observed 3 different patterns of results. Among the majority of fish, there was a strong correlation between the ELISA value and the qPCR value. However, subsets of fish exhibited either low ELISA values with elevated qPCR values or higher ELISA values with very low qPCR values. These observations suggest a conceptual model that allows inferences about the state of infection of individual fish based on dual ELISA/qPCR results. Although this model requires further assessment through experimental infections and treatments, it may have utility in broodstock selection programs that currently apply egg-culling practices based on ELISA alone.
Enzyme-linked immunosorbent assay for Potomac horse fever disease.
Pretzman, C I; Rikihisa, Y; Ralph, D; Gordon, J C; Bech-Nielsen, S
1987-01-01
An enzyme-linked immunosorbent assay (ELISA) for immunoglobulin G (IgG) and IgM in natural and experimental infections of equids with Ehrlichia risticii was developed. Ehrlichial organisms purified from an infected mouse macrophage cell line were used as the antigen. IgM was separated from serum IgG by the expedient of spun-column chromatography, allowing the use of an indirect ELISA for quantitation of both IgG and IgM in the test sera. Among 16 paired sera from horses exhibiting clinical signs of Potomac horse fever, 8 were positive by the indirect fluorescent-antibody test (IFA), 11 were positive by the IgG ELISA, and 8 were positive by the IgM ELISA. All IFA-positive specimens were positive by the IgG ELISA, which appeared to be more sensitive than the IFA. In all cases, the IgG ELISA alone would have sufficed for diagnosis when acute- and convalescent-phase sera were available. When 26 single acute- or convalescent-phase serum samples were tested, the IFA detected 8, the IgG ELISA detected 10, and the IgM ELISA detected 6 positive serum specimens. The kinetics of IgG and IgM responses as determined by ELISA in two experimentally infected ponies which survived infection and challenges revealed that specific IgM was short-lived, falling to undetectable levels by day 60 postinoculation, whereas specific IgG persisted for more than 1 year. IgM and IgG were detected as early as days 1 and 10, respectively, postinoculation. The results suggest that the ELISA is more sensitive than the IFA and that the IgM ELISA may provide a means for early diagnosis of Potomac horse fever at or before the onset of clinical signs.
Bueno, Ednéia C.; Snege, Miriam; Vaz, Adelaide J.; Leser, Paulo G.
2001-01-01
Neurocysticercosis (NC), caused by the presence of Taenia solium metacestodes in tissues, is a severe parasitic infection of the central nervous system with universal distribution. To determine the efficiency of enzyme-linked immunosorbent assay (ELISA) and immunoblot with antigens of T. crassiceps vesicular fluid (Tcra) compared to standard techniques (indirect immunofluorescence test [IFT] and complement fixation test [CFT]) using T. solium cysticerci (Tso) for the serodiagnosis of NC, we studied serum samples from 24 patients with NC, 30 supposedly healthy individuals, 76 blood bank donors, 45 individuals with other non-NC parasitoses, and 97 samples from individuals screened for cysticercosis serology (SC). The sensitivity observed was 100% for ELISA-Tso and ELISA-Tcra, 91.7% for the IFT, and 87.5% for the CFT. The specificity was 90% for ELISA-Tso, 96.7% for ELISA-Tcra, 50% for IFT, and 63.3% for CFT. The efficiency was highest for ELISA-Tcra, followed by ELISA-Tso, IFT, and CFT. Of the 23 samples from SC group, which were reactive to ELISA-Tso and/or ELISA-Tcra, only 3 were positive to immunblot-Tcra (specific peptides of 14- and 18-kDa) and to glycoprotein peptides purified from Tcra antigen (gp-Tcra), showing the low predictive value of ELISA for screening. None of the samples from the remaining groups showed specific reactivity in immunoblot-Tcra. These results demonstrate that ELISA-Tcra can be used as a screening method for the serodiagnosis of NC and support the need for specific tests for confirmation of the results. The immunoblot can be used as a confirmatory test both with Tcra and gp-Tcra, with the latter having an advantage in terms of visualization of the results. PMID:11687454
Kunita, Satoshi; Chaya, Miyuki; Hagiwara, Kozue; Ishida, Tomoko; Takakura, Akira; Sugimoto, Tatsuya; Iseki, Hiroyoshi; Fuke, Kumiko; Sugiyama, Fumihiro; Yagami, Ken-ichi
2006-04-01
Nucleotide sequences of mouse parvovirus (MPV) isolate, named MPV/UT, and mouse minute virus (MMV) were analyzed and used for expressing recombinant proteins in E. coli. ELISA tests using recombinant major capsid protein (rVP2) and recombinant major non-structural protein (rNS1) as antigens were developed and their performance in serologic detection of rodent parvovirus infection was assessed. MPV-rVP2 and MMV-rVP2 ELISAs reacted specifically with anti-MPV and anti-MMV mouse sera, respectively. MMV-rNS1 antigen had a wide reaction range with antisera to rodent parvoviruses including MPV, MMV, Kilham rat virus (KRV) and H-1 virus. All mice oronasally infected with MPV were seropositive at 4 weeks post-infection in screening by ELISAs using MPV-rVP2 and MMV-rNS1 antigens, but were negative by conventional ELISA using whole MMV antigen. A contact transmission experiment revealed that transmission of MPV occurred up to 4 weeks post-infection, and all cage mates were seropositive in screening with MPV-rVP2 and MMV-rNS1 ELISAs. These results indicate that MPV-rVP2 and MMV-rVP2 are specific ELISA antigens which distinguish between MPV and MVM infection, while MMV-rNS1 antigen can be used in generic ELISA for a variety of rodent parvoviruses. The higher sensitivity of MPV-rVP2 ELISA than conventional ELISA for detecting seroconversion to MPV in oronasally infected mice as well as in cage mates suggests the usefulness of MPV-rVP2 ELISA in quarantine and microbiological monitoring of MPV infection in laboratory mice.
An ELISA Lab-on-a-Chip (ELISA-LOC).
Rasooly, Avraham; Bruck, Hugh A; Kostov, Yordan
2013-01-01
Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.
Quigley, A; Sekiya, M; Egan, S; Wolfe, A; Negredo, C; Mulcahy, G
2017-03-01
There is little information on the prevalence of Fasciola hepatica infection in the horse population in Ireland or the potential impact of fluke infection on animal health. To investigate F. hepatica infection in the Irish horse population and to assess the diagnostic potential of an indirect enzyme-linked immunosorbent assay (ELISA) based on the F. hepatica recombinant cathepsin L1 (CL1) antigen. Cross-sectional abattoir survey of horses for liver fluke status. Animals (n = 200) were examined at an abattoir between May 2013 and April 2014. Horses were graded ante mortem for body condition score. Blood and faeces were collected and livers were examined post mortem by gross morphology. A cohort (n = 35) of livers were also examined histologically. Haematology and blood biochemistry, including serum liver enzyme activities, were measured and faeces were sedimented for egg counts. Serum was assayed by indirect ELISA using a recombinant CL1. The prevalence of liver fluke infection was 9.5%. There was no correlation between liver fluke status and time of year, breed classification, age group, sex, body condition score, ante mortem assessment, strongyle infection status, serum liver enzyme activities or CL1 concentration. A comparison of the CL1 ELISA in horse sera compared with a reference standard diagnosis showed high specificity of 95.6% (95% confidence interval [CI] 91.5-98.0%), but low sensitivity of 42.1% (95% CI 20.2-66.5%). This study is limited by its nature as an abattoir study, the relatively small number of animals examined (n = 200), and the absence of a known negative group of horses. Blood biomarkers are not good indicators of liver fluke infection and the CL1 ELISA is not a sensitive tool for diagnosis of fluke infection in the horse. The prevalence of F. hepatica in horses indicates that further research is required to assess the potential impact of liver fluke on equine liver health. © 2016 EVJ Ltd.
Measuring Hordein (Gluten) in Beer – A Comparison of ELISA and Mass Spectrometry
Blundell, Malcolm J.; Goswami, Hareshwar P.; Howitt, Crispin A.
2013-01-01
Background Subjects suffering from coeliac disease, gluten allergy/intolerance must adopt a lifelong avoidance of gluten. Beer contains trace levels of hordeins (gluten) which are too high to be safely consumed by most coeliacs. Accurate measurement of trace hordeins by ELISA is problematic. Methods We have compared hordein levels in sixty beers, by sandwich ELISA, with the level determined using multiple reaction monitoring mass spectrometry (MRM-MS). Results Hordein levels measured by ELISA varied by four orders of magnitude, from zero (for known gluten-free beers) to 47,000 µg/mL (ppm; for a wheat-based beer). Half the commercial gluten-free beers were free of hordein by MS and ELISA. Two gluten-free and two low-gluten beers had zero ELISA readings, but contained significant hordein levels (p<0.05), or near average (60–140%) hordein levels, by MS, respectively. Six beers gave false negatives, with zero ELISA readings but near average hordein content by MS. Approximately 20% of commercial beers had ELISA readings less than 1 ppm, but a near average hordein content by MS. Several barley beers also contained undeclared wheat proteins. Conclusions ELISA results did not correlate with the relative content of hordein peptides determined by MS, with all barley based beers containing hordein. We suggest that mass spectrometry is more reliable than ELISA, as ELISA enumerates only the concentration of particular amino-acid epitopes; this may vary between different hordeins and may not be related to the absolute hordein concentration. MS quantification is undertaken using peptides that are specific and unique, enabling the quantification of individual hordein isoforms. This outlines the problem of relying solely on ELISA determination of gluten in beverages such as beer and highlights the need for the development of new sensitive and selective quantitative assay such as MS. PMID:23509606
2011-01-01
Background The entomological inoculation rate (EIR) is an important indicator in estimating malaria transmission and the impact of vector control. To assess the EIR, the enzyme-linked immunosorbent assay (ELISA) to detect the circumsporozoite protein (CSP) is increasingly used. However, several studies have reported false positive results in this ELISA. The false positive results could lead to an overestimation of the EIR. The aim of present study was to estimate the level of false positivity among different anopheline species in Cambodia and Vietnam and to check for the presence of other parasites that might interact with the anti-CSP monoclonal antibodies. Methods Mosquitoes collected in Cambodia and Vietnam were identified and tested for the presence of sporozoites in head and thorax by using CSP-ELISA. ELISA positive samples were confirmed by a Plasmodium specific PCR. False positive mosquitoes were checked by PCR for the presence of parasites belonging to the Haemosporidia, Trypanosomatidae, Piroplasmida, and Haemogregarines. The heat-stability and the presence of the cross-reacting antigen in the abdomen of the mosquitoes were also checked. Results Specimens (N = 16,160) of seven anopheline species were tested by CSP-ELISA for Plasmodium falciparum and Plasmodium vivax (Pv210 and Pv247). Two new vector species were identified for the region: Anopheles pampanai (P. vivax) and Anopheles barbirostris (Plasmodium malariae). In 88% (155/176) of the mosquitoes found positive with the P. falciparum CSP-ELISA, the presence of Plasmodium sporozoites could not be confirmed by PCR. This percentage was much lower (28% or 5/18) for P. vivax CSP-ELISAs. False positive CSP-ELISA results were associated with zoophilic mosquito species. None of the targeted parasites could be detected in these CSP-ELISA false positive mosquitoes. The ELISA reacting antigen of P. falciparum was heat-stable in CSP-ELISA true positive specimens, but not in the false positives. The heat-unstable cross-reacting antigen is mainly present in head and thorax and almost absent in the abdomens (4 out of 147) of the false positive specimens. Conclusion The CSP-ELISA can considerably overestimate the EIR, particularly for P. falciparum and for zoophilic species. The heat-unstable cross-reacting antigen in false positives remains unknown. Therefore it is highly recommended to confirm all positive CSP-ELISA results, either by re-analysing the heated ELISA lysate (100°C, 10 min), or by performing Plasmodium specific PCR followed if possible by sequencing of the amplicons for Plasmodium species determination. PMID:21767376
Kitashoji, Emi; Koizumi, Nobuo; Lacuesta, Talitha Lea V; Usuda, Daisuke; Ribo, Maricel R; Tria, Edith S; Go, Winston S; Kojiro, Maiko; Parry, Christopher M; Dimaano, Efren M; Villarama, Jose B; Ohnishi, Makoto; Suzuki, Motoi; Ariyoshi, Koya
2015-01-01
Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cell-based IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/culture/LAMP. The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigA-IgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection.
Kitashoji, Emi; Koizumi, Nobuo; Lacuesta, Talitha Lea V.; Usuda, Daisuke; Ribo, Maricel R.; Tria, Edith S.; Go, Winston S.; Kojiro, Maiko; Parry, Christopher M.; Dimaano, Efren M.; Villarama, Jose B.; Ohnishi, Makoto; Suzuki, Motoi; Ariyoshi, Koya
2015-01-01
Background Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. Methodology/Principal Findings A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cell-based IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/culture/LAMP. Conclusions/Significance The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigA-IgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection. PMID:26110604
Parker, A M; House, J K; Hazelton, M S; Bosward, K L; Morton, J M; Sheehy, P A
2017-10-01
In Australia, one of the biosecurity recommendations to help prevent the introduction of Mycoplasma bovis into a dairy herd is to use a PCR assay on bulk tank milk (BTM) samples to evaluate the M. bovis infection status of potential source herds. An alternative approach is to assess the immunological status of the herd with respect to previous exposure to M. bovis via the use of an ELISA that is commercially available for use on cattle milk and serum. The objectives of this study were to (1) evaluate factors potentially associated with variation in the ELISA BTM optical density coefficient (ODC%) in previously exposed herds, (2) evaluate the association between the proportion of cows that are ELISA positive and the BTM ELISA ODC%, (3) assess agreement between the BTM ELISA and PCR and culture, and (4) compare BTM ELISA ODC% between the "hospital" herd and the main lactating herd on the same farm. Bulk tank milk samples (n = 192) were collected from 19 dairy herds with a history of clinical M. bovis disease and from 6 control herds (herds with no known clinical cases of mycoplasmosis). For 28 of the BTM samples collected, blood was also collected from 50 lactating cows contributing to that bulk tank sample. From 1 herd, concurrent paired BTM samples were collected from the main herd and the hospital herd on 16 occasions. All BTM samples were analyzed by ELISA (Bio-X Bio K 302, Bio-X Diagnostics, Rochefort, Belgium), PCR, and culture. The BTM ELISA ODC% was associated with time since initial M. bovis outbreak and time since the start of the herd's calving period. Following an initial outbreak of M. bovis, the BTM ELISA ODC% was highest in the first 8 mo. In split- and seasonal-calving herds, significantly higher BTM ELISA ODC% results were observed 5 to 8 wk after the commencement of the calving period. A significant association was observed between the within-herd seroprevalence for the lactating herd and BTM ELISA ODC%, but within-herd seroprevalence explained little of the variation in BTM ELISA ODC%. When comparing the BTM ELISA with a multiplex probe PCR and culture followed by 16S to 23S rRNA sequencing, there was virtually no agreement above that expected by chance; prevalence-adjusted bias-adjusted kappa values were 0.22 and 0.25 for ELISA category versus PCR category and culture, respectively. Finally, the hospital herd BTM ELISA ODC% mirrored that for the main herd BTM but was significantly higher. This study demonstrates that this commercially available ELISA used on BTM samples may complement the use of BTM PCR or culture in identifying herds from which purchase of animals may pose a higher biosecurity risk for introduction of M. bovis into noninfected herds. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip
2017-07-01
Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.
Alcorn, S.W.; Pascho, R.J.
2000-01-01
An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.
Verma, J; Singh, B P; Gangal, S V; Arora, N; Sridhara, S
2000-08-01
Grass pollens are known to induce type I allergic reactions in a large number of genetically predisposed individuals. Earlier studies have recognized Imperata cylindrica (Ic) pollen as an important source of aeroallergen which contained 7 IgE binding proteins in the MW range of 85-16 kD. To isolate, purify and characterize a cross-reactive allergenic protein from Ic pollen extract for diagnosis and therapy of grass pollen allergy. Ic pollen extract was fractionated using DEAE Sephadex A-50, Sephadex G-200 and Mono Q column. Allergenic activity of the fractions was checked by ELISA, skin tests, ELISA inhibition and immunoblot using sera of Ic-sensitive patients. A 67-kD protein was purified to homogeneity from Ic-VIII. The allergenic determinants of this protein were identified by SDS-PAGE and immunoblot after CNBr treatment. Among Ic fractions, Ic-VIII was highly potent by ELISA, skin tests and showed cross-reactivity with 4 other tropical grasses by immunoblot and ELISA inhibition. The subfraction Ic-VIIIe1 of Ic-VIII showed a band at 67 kD on SDS-PAGE. On CNBr treatment, it gave 7 peptides, 3 of which were found to be allergenic. A 67-kD protein (Ic-VIIIe1) was isolated, purified to homogeneity and partially characterized. It showed cross-reactivity with tropical grasses tested and contained at least three allergenic determinants. Copyright 2000 S. Karger AG, Basel.
Borromeo, V; Berrini, A; De Grandi, F; Cremonesi, F; Fiandanese, N; Pocar, P; Secchi, C
2014-07-01
The development of a novel enzyme-linked immunosorbent assay (ELISA) for determining luteinizing hormone (LH) in bovine plasma is described. Anti-bovine LH (bLH) monoclonal antibodies (mAbs) were produced and characterized. One mAb recognizing the bLH β subunit was used for immunoaffinity purification of substantial amounts of biologically active bLH from pituitary glands. The purified bLH in combination with 2 anti-bLH β subunit mAbs was used to develop a sandwich ELISA, which satisfied all the criteria required to investigate LH secretory patterns in the bovine species. The ELISA standard curve was linear over the range 0.05 to 2.5 ng/mL, and the assay proved suitable for measuring bLH in plasma without any prior treatment of samples. Cross-reactivity and recovery tests confirmed the specificity of the method. The intra- and inter-assay coefficients of variation ranged between 3.41% and 9.40%, and 9.29% and 15.84%, respectively. The analytical specificity of the method was validated in vivo by provocative tests for LH in heifers, using the LH releasing peptide gonadotropin-releasing hormone. In conclusion, the adoption of mAbs for this ELISA for coating the wells and labeling, combined with the easy one-step production of reference bLH, ensures long-term continuity in large-scale measurements of LH in the bovine species. Copyright © 2014 Elsevier Inc. All rights reserved.
Yamada, Takayuki; Takagi, Akira; Takeshita, Kyosuke; Yamamoto, Koji; Ito, Masafumi; Matsushita, Tadashi; Murate, Takashi; Saito, Hidehiko; Kojima, Tetsuhito
2003-01-01
We developed a sensitive immunoassay to determine the concentration of mouse plasminogen activator inhibitor-1. The assay was a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) based on the production of a specific polyclonal antibody against mouse plasminogen activator inhibitor type-1 (PAI-1) used both as a trapping and detecting antibody. This antibody was raised in a rabbit by direct introduction of the expression vector plasmid DNA encoding mouse PAI-1, instead of conventional immunization with the purified protein. The standard curve was constructed with a recombinant glutathione S-transferase (GST)-mouse PAI-1 fusion protein (GST-mPAI-1) and dose-response of the assay was linear for GST-mPAI-1 between 6.25 and 100 pM. In order to assess the consistency of the assay, we measured PAI-1 antigen in normal mouse pooled plasma several times. We found that the intra-assay and inter-assay coefficients of variation (CV) were 4.8% and 9.2%, respectively, indicating that the ELISA would be sufficiently repeatable and reproducible. In this assay, lipopolysaccharide (LPS)-injected mice showed substantially higher levels (22-fold) of plasma PAI-1 antigen than did control mice (12.5+/-2.4 vs. 0.58+/-0.16 nM), similar to results reported elsewhere. Taken together, the DNA vaccine method is extremely useful for preparing specific antibodies against mouse PAI-1, which can be utilized to establish the ELISA and analyze the profile of PAI-1 distributions in mice under various conditions. This approach might also be useful for immunological investigation of other coagulation factors and related proteins.
Fukushi, Shuetsu; Fukuma, Aiko; Kurosu, Takeshi; Watanabe, Shumpei; Shimojima, Masayuki; Shirato, Kazuya; Iwata-Yoshikawa, Naoko; Nagata, Noriyo; Ohnishi, Kazuo; Ato, Manabu; Melaku, Simenew Keskes; Sentsui, Hiroshi; Saijo, Masayuki
2018-01-01
Since discovering the Middle East respiratory syndrome coronavirus (MERS-CoV) as a causative agent of severe respiratory illness in the Middle East in 2012, serological testing has been conducted to assess antibody responses in patients and to investigate the zoonotic reservoir of the virus. Although the virus neutralization test is the gold standard assay for MERS diagnosis and for investigating the zoonotic reservoir, it uses live virus and so must be performed in high containment laboratories. Competitive ELISA (cELISA), in which a labeled monoclonal antibody (MAb) competes with test serum antibodies for target epitopes, may be a suitable alternative because it detects antibodies in a species-independent manner. In this study, novel MAbs against the spike protein of MERS-CoV were produced and characterized. One of these MAbs was used to develop a cELISA. The cELISA detected MERS-CoV-specific antibodies in sera from MERS-CoV-infected rats and rabbits immunized with the spike protein of MERS-CoV. The MAb-based cELISA was validated using sera from Ethiopian dromedary camels. Relative to the neutralization test, the cELISA detected MERS-CoV-specific antibodies in 66 Ethiopian dromedary camels with a sensitivity and specificity of 98% and 100%, respectively. The cELISA and neutralization test results correlated well (Pearson's correlation coefficients=0.71-0.76, depending on the cELISA serum dilution). This cELISA may be useful for MERS epidemiological investigations on MERS-CoV infection. Copyright © 2017 Elsevier B.V. All rights reserved.
Jaskowski, Troy D; La'ulu, Sonia L; Mahler, Michael; Tebo, Anne E
2017-09-01
We investigated the performance of an ELISA for the detection of 3-hydroxy-3-methyl-glutaryl-coenzyme A reductase (HMGCR) IgG antibodies in immune-mediated necrotizing myopathies (IMNM). Patients positive for HMGCR antibodies (n=61) or negative (n=78) by protein immunoprecipitation (IP), and healthy controls (n=100) were used to evaluate the ELISA. Unique consecutive serum samples (n=155) received at ARUP Laboratories for HMGCR IgG testing by ELISA were also investigated and analysed for serum muscle enzymes (aldolase, creatine kinase, and myoglobin). The ELISA's sensitivity, specificity, and percentage agreement were assessed relative to IP. Correlation between specific muscle enzyme concentration and the presence of HMGCR antibody was determined. Overall agreement between ELISA and IP was 93.4%. Using the IP as reference, the sensitivity and specificity of the ELISA was 95.1%, and 100%, respectively. Inter- and intra-assay coefficient of variation of the ELISA was <10.0%, and ≤15.0%, respectively. In the consecutive cohort, 21 (13.6%) samples tested positive for HMGCR IgG. Concentrations of aldolase, creatine kinase, and myoglobin were significantly higher (all p<0.0001) in patients positive for HMGCR antibodies at the time of evaluation. We confirm significant reliability of HMGCR antibodies as measured by the ELISA for the evaluation of IMNM. Copyright © 2017 Elsevier B.V. All rights reserved.
Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays
Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D
2002-01-01
Aims: To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). Methods: The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques—an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. Results: All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (κ > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (κ = 0.63). Conclusion: The assay kit marketed as Varelisa allows accurate detection of LKM1. PMID:12461054
Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.
Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D
2002-12-01
To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.
Aydin, Suleyman
2015-10-01
Playing a critical role in the metabolic homeostasis of living systems, the circulating concentrations of peptides/proteins are influenced by a variety of patho-physiological events. These peptide/protein concentrations in biological fluids are measured using various methods, the most common of which is enzymatic immunoassay EIA/ELISA and which guide the clinicians in diagnosing and monitoring diseases that inflict biological systems. All the techniques where enzymes are employed to show antigen-antibody reactions are generally referred to as enzymatic immunoassay EIA/ELISA method. Since the basic principles of EIA and ELISA are the same. The main objective of this review is to present an overview of the historical journey that had led to the invention of EIA/ELISA, an indispensible method for medical and research laboratories, types of ELISA developed after its invention [direct (the first ELISA method invented), indirect, sandwich and competitive methods], problems encountered during peptide/protein analyses (pre-analytical, analytical and post-analytical), rules to be followed to prevent these problems, and our laboratory experience of more than 15 years. Copyright © 2015 Elsevier Inc. All rights reserved.
Homologous ELISA for detection of oligomeric human TNF: properties of the assay.
Petyovka, N; Lyach, L; Voitenok, N N
1995-10-26
In order to quantify oligomeric human tumor necrosis factor-alpha (TNF), we have developed a sensitive homologous enzyme-linked immunosorbent assay (Hm-ELISA) using the same monoclonal antibody (MoAb) for both solid and liquid phase. Different anti-TNF MoAb have been compared in terms of their efficacy in the Hm-ELISA, affinity, neutralization capacity and epitope specificity. The data suggest, that effectiveness in the Hm-ELISA may represent a novel characteristic of MoAb. Of the MoAbs tested, 5 N was capable of recognizing oligomeric TNF in the Hm-ELISA with a detection limit of 15 pg/ml. Furthermore, using Hm-ELISA against human TNF, interleukin-8 (IL-8) and lymphotoxin, we have demonstrated that these cytokines are oligomeric in physiological solutions, but are converted into monomeric forms in the presence of the non-ionic detergent Tween 20. High salt buffer was employed to abrogate a nonspecific false positive reaction in the Hm-ELISA found in nearly half of the plasma samples obtained from healthy subjects. Finally, a good correlation between the Hm-ELISA and the L929 bioassay was observed for natural and recombinant TNF measured in human plasma.
[Use of new immunoglobulin isotype-specific ELISA-systems to detect Salmonella infections in pigs].
Ehlers, Joachim; Alt, Michael; Trepnau, Daniela; Lehmann, Jörg
2006-01-01
In Germany, the program for controlling salmonella infections in pigs is based on tests detecting salmonella-lipopolysaccharide (LPS) induced antibodies in meat-juice or blood. These conventional tests which are based on the technology of enzyme-linked immunosorbent assay (ELISA) detect exclusively or mainly immunoglobulin(lg)G antibodies. Meanwhile, novel ELISA systems (WCE-ELISA, 3-Isotype-Screening-ELISA) have been developed, which additionally detect the antibody classes IgM and IgA.This fact enables the registration of fresh salmonella infections (starting with day 5 p.i.) and thus, the distinction between early and older infections. The results show that animals with early salmonella infections appear significantly more often in herds with a high than with a low prevalence. With the newly developed tests this group of animals can be detected much more efficiently and precisely than with the tests used so far. Due to their clearly improved sensitivity the application of the WCE-ELISA and the 3-Isotype-Screening-ELISA in terms of the QS-Salmonella-Monitoring program can therefore significantly improve the selection of farms with potential salmonella excretors. Additionally, the WCE-ELISA can be applied very suitable for the examination of individual animals.
Grzela, Katarzyna; Zagórska, Wioletta; Krejner, Alicja; Litwiniuk, Malgorzata; Zawadzka-Krajewska, Anna; Kulus, Marek; Grzela, Tomasz
2017-04-01
Matrix metalloproteinase (MMP)-9 is involved in pathophysiology of asthma, mainly asthma-associated airway remodeling. Exhaled breath condensates (EBC) of asthmatics contain increased amounts of MMP-9 with activity higher, than in healthy controls. The increased activity of MMP-9 may originate from its excessive production and activation, but may also result from variations in MMP-9 structure, which are determined by single nucleotide polymorphisms (SNPs). In this pilot study we aimed to assess the possible influence of two functional MMP-9 polymorphisms, Q279R and R668Q, on enzymatic activity of MMP-9, measured in EBC of asthmatic children. The concentration and activity of MMP-9 were analyzed in EBC of 20 children with allergic asthma using specific standard ELISA and novel immunoenzymatic activity assay. The SNPs of MMP-9 were assessed using real-time PCR-based genotyping test. We have found that MMP-9 concentration in breath condensates of children with stable asthma was slightly higher in ELISA, than in the activity assay. Moreover, these results and activity-to-amount ratio have revealed some relationship with a presence of specific 279R and/or 668Q MMP-9 gene variants. Our observation suggests that at least in some patients MMP-9 hyperactivity may result from genetic predisposition, determined by polymorphic variants of MMP-9 gene. Moreover, it supports previous reports postulating significance of MMP-9 in pathogenesis of asthma. However, this issue still requires further studies.
Giraldo, Mónica; Portela, Ricardo W. D.; Snege, Mirian; Leser, Paulo G.; Camargo, Mário E.; Mineo, José Roberto; Gazzinelli, Ricardo T.
2002-01-01
In the present study we developed an enzyme-linked immunosorbent assay (ELISA) to measure immunoglobulin M (IgM) specific for glycoinositolphospholipids (GIPL) derived from tachyzoite membrane (IgM-GIPL ELISA). The sensitivity and specificity of the assay were compared with those of commercially available Toxoplasma-specific IgM serological tests, namely, immunofluorescence assay (IFA) with fixed tachyzoites and capture ELISA employing tachyzoite extracts. Our results show that all patients with acute toxoplasmosis, as determined by clinical data and conventional serological tests, were also positive by the IgM-GIPL ELISA. Interestingly, many patients that were classified as indeterminate, who had IgG with high avidity but positive results in the IgM-specific IFA and capture ELISA, were negative by the IgM-GIPL ELISA. Finally, we tested the sera from patients with rheumatoid arthritis and various parasitic infections and found no evidence of false positives in the IgM-GIPL ELISA. PMID:11923364
Optofluidic laser for dual-mode sensitive biomolecular detection with a large dynamic range
NASA Astrophysics Data System (ADS)
Wu, Xiang; Oo, Maung Kyaw Khaing; Reddy, Karthik; Chen, Qiushu; Sun, Yuze; Fan, Xudong
2014-04-01
Enzyme-linked immunosorbent assay (ELISA) is a powerful method for biomolecular analysis. The traditional ELISA employing light intensity as the sensing signal often encounters large background arising from non-specific bindings, material autofluorescence and leakage of excitation light, which deteriorates its detection limit and dynamic range. Here we develop the optofluidic laser-based ELISA, where ELISA occurs inside a laser cavity. The laser onset time is used as the sensing signal, which is inversely proportional to the enzyme concentration and hence the analyte concentration inside the cavity. We first elucidate the principle of the optofluidic laser-based ELISA, and then characterize the optofluidic laser performance. Finally, we present the dual-mode detection of interleukin-6 using commercial ELISA kits, where the sensing signals are simultaneously obtained by the traditional and the optofluidic laser-based ELISA, showing a detection limit of 1 fg ml-1 (38 aM) and a dynamic range of 6 orders of magnitude.
Development of an interleukin (IL)-33 sandwich ELISA kit specific for mature IL-33.
Kim, Eunsom; Kwak, Areum; Jhun, Hyunjhung; Lee, Siyoung; Jo, Seunghyun; Lee, Jongho; Kang, Tae-Bong; Her, Erk; Bae, Suyoung; Lee, Youngmin; Kim, Soohyun
2016-01-01
Interleukin (IL)-33 is an inflammatory cytokine and belongs to the IL-1 family of cytokines. There are eleven members of the IL-1 family of cytokines and all have important roles in host defense against infections. Their levels are increased during infection and in various auto-inflammatory diseases. IL-33 is also associated with autoimmune diseases such as asthma, atopic dermatitis, rheumatoid arthritis, and atherosclerosis. IL-33 receptors consist of IL-1R4 and IL-1R3 to induce both Th1 and Th2 type immune response. Here we present the development of monoclonal antibodies (mAbs) against human mature IL-33. Recombinant human mature IL-33 protein was expressed in E. coli and purified by multi-step affinity chromatography. The human IL-33 activity was examined in HMC-1 and Raw 264.7 cells. Mice were immunized with the biologically active mature IL-33 to generate mAb against IL-33. The anti-IL-33 mAb (clone/4) was used as a capture antibody for a sandwich enzyme-linked immunosorbent assay (ELISA). This assay detects mature IL-33 with a high sensitivity (80 pg/mL) but does not recognize the biologically inactive precursor IL-33. This article describes the methods for a newly developed IL-33 ELISA kit that is specific for mature IL-33 and may be used to analyze bioactive mature IL-33 in various immunological diseases.
Aburto-Mejía, Elsa; Santiago-Germán, David; Martínez-Marino, Manuel; María Eugenia Galván-Plata; Almeida-Gutiérrez, Eduardo; López-Alarcón, Mardia; Hernández-Juárez, Jesús; Alvarado-Moreno, Antonio; Leaños-Miranda, Alfredo; Majluf-Cruz, Abraham; Isordia-Salas, Irma
2017-01-01
Background . Metabolic and genetic factors induce plasminogen activator inhibitor type-1 (PAI-1) overexpression; higher PAI-1 levels decrease fibrinolysis and promote atherothrombosis. Aim . To assess PAI-1 antigen levels among subjects with type 2 diabetes mellitus (T2DM) plus Metabolic Syndrome (MetS) before clinical manifestations of atherothrombosis and the contribution of metabolic factors and 4G/5G polymorphism of PAI-1 gene on the variability of PAI-1. Methods . We conducted an observational, cross-sectional assay in a hospital in Mexico City from May 2010 to September 2011. MetS was defined by the International Diabetes Federation criteria. PAI-1 levels and 4G/5G polymorphism were determined by ELISA and PCR-RFLP analysis. Results . We enrolled 215 subjects with T2DM plus MetS and 307 controls. Subjects with T2DM plus MetS had higher PAI-1 levels than the reference group (58.4 ± 21 versus 49.9 ± 16 ng/mL, p = 0.026). A model with components of MetS explained only 12% of variability on PAI-1 levels ( R 2 = 0.12; p = 0.001), with β = 0.18 ( p = 0.03) for hypertension, β = -0.16 ( p = 0.05) for NL HDL-c, and β = 0.15 ( p = 0.05) for NL triglycerides. Conclusion . Subjects with T2DM plus MetS have elevated PAI-1 levels before clinical manifestations of atherothrombotic disease. Metabolic factors have a more important contribution than 4G/5G polymorphism on PAI-1 plasma variability.
Bentow, C; Lakos, G; Martis, P; Wahl, E; Garcia, M; Viñas, O; Espinosa, G; Cervera, R; Sjöwall, C; Carmona-Fernandes, D; Santos, M J; Hanly, J G; Mahler, M
2016-07-01
Anti-double stranded desoxyribonucleic acid (anti-dsDNA) antibodies are considered fairly specific for systemic lupus erythematosus (SLE) and their quantification is useful for the clinical management of SLE patients. We assessed the diagnostic performance of the QUANTA Flash dsDNA chemiluminescent immunoassay (CIA) in comparison to an ELISA, using patients from five participating countries. The main focus was to evaluate the correlation between anti-dsDNA antibody results from the CIA and global SLE disease activity, as measured by the SLE Disease Activity Index 2000 (SLEDAI-2K). A total of 1431 samples (SLE, n = 843; disease controls, n = 588) from five countries (Canada, USA, Portugal, Sweden and Spain) were tested with QUANTA Flash dsDNA (Inova Diagnostics, San Diego, CA, USA). Data obtained with the QUANTA Lite dsDNA SC ELISA (Inova Diagnostics) were available for samples from three sites (Canada, USA and Sweden, n = 566). The SLEDAI-2K scores were available for 805 SLE patients and a cut-off of > 4 was used to define active disease. QUANTA Flash dsDNA had a sensitivity of 54.3% for the diagnosis of SLE, combined with 89.8% specificity. Anti-dsDNA antibody levels were significantly higher (p < 0.0001) in active SLE (SLEDAI-2K > 4; n = 232; median value 83.0 IU/mL) versus the inactive patients (n = 573; median value 22.3 IU/mL), and the SLEDAI-2K scoring correlated with their dsDNA antibody levels (Spearman's rho = 0.44, p < 0.0001). Similar but less pronounced findings were also found for the ELISA, in relation to disease activity. The QUANTA Flash dsDNA assay showed good clinical performance in a large international multi-center study. Additionally, the strong correlation between anti-dsDNA antibody results and SLEDAI-2K scores supported the potential utility of QUANTA Flash dsDNA for monitoring disease activity. © The Author(s) 2016.
Ignat'eva, G A; Maksiutov, A Z; L'vov, V L; Kolobov, A A; Ignat'ev, T I
2011-01-01
The short multiepitopic synthetic peptides from the sequences of hypervariable area of V3-loope of gp120 of HIV don't induce anti-peptides antibodies production in mice themselves. We prepared the potent immunogen by noncovalent conjugations of the multitude peptides with pure peptidoglycans from cell wall of Salmonella typhi. The sera from immunized mice have the anti-peptides antibody titers (3-5) x 10(5) in ELISA, as high as Freund's adjuvant is of use.
Sero-survey of Avian Influenza in backyard poultry and wild bird species in Iran-2014.
Fallah Mehrabadi, M H; Bahonar, A R; Vasfi Marandi, M; Sadrzadeh, A; Tehrani, F; Salman, M D
2016-06-01
In almost all villages in Iran backyard birds, especially chickens, are kept for egg and meat production. AI H9N2 subtype is endemic in Iran. Therefore, estimation of AI prevalence among these birds is important to determine the risk of transmission of infection to commercial farms. The aim of this study was to estimate subclinical infections or previous exposure to H5, H7, and H9 subtypes and to identify potentially important determinants of prevalence of this infectious at premises level in backyard poultry, bird gardens, zoos, and wild bird markets in Iran. A survey was conducted using a cross-sectional design throughout the entire country. A total of 329 villages, seven bird gardens, three zoos and five wild bird markets were included. In each village four families that kept birds were included in the collection of biological samples and background information. The Enzyme-Linked Immunosorbent Assay (ELISA) was used as the screening test and all ELISA-positive samples were examined with the HI test to differentiate H5, H7, and H9. Among the bird gardens, eight of 15 premises (53.3%) were positive in both the ELISA test and HI for H9N2. Testing of samples collected in the villages revealed that 296 out of 329 villages (90%) had positive ELISA tests and also HI tests for H9. The HI-H9 mean titers in positive units were significantly higher than negative units (P<.001). This study revealed no significant statistical differences between risk variables in seropositive and seronegative bird gardens in the case of H9 (P>.05). The results of this study showed that among the risk variables, mountainous area was a protective factor and lack of hygienic disposal of dead birds was a risk factor for AI; this was also observed in rural poultry. The high sero-prevalence of influenza H9N2 in rural domestic poultry indicates that the disease is endemic. It is necessary to include backyard poultry in any surveillance system and control strategy due to the existence of AIV in backyard poultry and the possibility of transmission of infection to commercial poultry farms. Implementation of an AI surveillance program and biosecurity measures can be useful to control this infection and prevent AI from spreading to commercial farms. Furthermore in Iran there is no program for destruction of birds infected with the H9N2, so an effective vaccination program with regard to issues such as acceptability and cost-benefit must play an important role in reducing infections in backyard poultry. Copyright © 2016. Published by Elsevier B.V.
Aghebati-Maleki, Leili; Younesi, Vahid; Baradaran, Behzad; Abdolalizadeh, Jalal; Motallebnezhad, Morteza; Nickho, Hamid; Shanehbandi, Dariush; Majidi, Jafar; Yousefi, Mehdi
2017-04-01
Receptor tyrosine kinase-like orphan receptor (ROR) proteins are a conserved family of tyrosine kinase receptors that function in developmental processes including cell survival, differentiation, cell migration, cell communication, cell polarity, proliferation, metabolism, and angiogenesis. ROR1 has recently been shown to be expressed in various types of cancer cells but not normal cells. Pharmacokinetics and pharmacodynamics of single-chain Fragment variable (scFv) antibodies provide potential therapeutic advantages over whole antibody molecules. In the present study, scFvs against a specific peptide from the extracellular domain of ROR1 were selected using phage display technology. The selected scFvs were further characterized using polyclonal and monoclonal phage enzyme-linked immunosorbent assay (ELISA), soluble monoclonal ELISA, colony PCR, and sequencing. Antiproliferative and apoptotic effects of selected scFv antibodies were also evaluated in lymphoma and myeloma cancer cell lines using MTT and annexin V/PI assays. The results of ELISA indicated specific reactions of the isolated scFvs against the ROR1 peptide. Colony PCR confirmed the presence of full-length V H and Vκ inserts. The percentages of cell growth after 24 h of treatment of cells with individual scFv revealed that the scFv significantly inhibited the growth of the RPMI8226 and chronic lymphocytic leukemia (CLL) cells in comparison with the untreated cells ( p < 0.05). Interestingly, 24-h treatment with specific scFv induced apoptosis cell death in the RPMI8226 and CLL cells. Taken together, our results demonstrate that targeting of ROR1 using peptide-specific scFv can be an effective immunotherapy strategy in hematological malignancies.
El Aswad, Bahaa El Deen Wade; Doenhoff, Michael J; El Hadidi, Abeer Shawky; Schwaeble, Wilhelm J; Lynch, Nicholas J
2011-03-01
Schistosomiasis is traditionally diagnosed by microscopic detection of ova in stool samples, but this method is labour intensive and its sensitivity is limited by low and variable egg secretion in many patients. An alternative is an ELISA using Schistosoma mansoni soluble egg antigen (SEA) to detect anti-schistosome antibody in patient samples. SEA is a good diagnostic marker in non-endemic regions but is of limited value in endemic regions, mainly because of its high cost and limited specificity. Here we assess seven novel antigens for the detection of S. mansoni antibody in an endemic region (the Northern Nile Delta). Using recombinant S. mansoni calreticulin (CRT) and fragments thereof, anti-CRT antibodies were detected in the majority of 97 patients sera. The diagnostic value of some of these antigens was, however, limited by the presence of cross-reacting antibody in the healthy controls, even those recruited in non-endemic areas. Cercarial transformation fluid (CTF), a supernatant that contains soluble material released by the cercariae upon transformation to the schistosomula, is cheaper and easier to produce than SEA. An ELISA using CTF as the detection antigen had a sensitivity of 89.7% and an estimated specificity of 100% when used in non-endemic regions, matching the performance of the established SEA ELISA. CTF was substantially more specific than SEA for diagnosis in the endemic region, and less susceptible than SEA to cross-reacting antibody in the sera of controls with other protozoan and metazoan infections. Copyright © 2010 Elsevier GmbH. All rights reserved.
Simmons, Monika; Porter, Kevin R; Hayes, Curtis G; Vaughn, David W; Putnak, Robert
2006-10-01
We evaluated three nonreplicating dengue virus type 2 (DENV-2) vaccines: (i) a DNA vaccine containing the prM-E gene region (D), (ii) a recombinant subunit protein vaccine containing the B domain (i.e., domain III) of the E protein as a fusion with the Escherichia coli maltose-binding protein (R), and (iii) a purified inactivated virus vaccine (P). Groups of four rhesus macaques each were primed once and boosted twice using seven different vaccination regimens. After primary vaccination, enzyme-linked immunosorbent assay (ELISA) antibody levels increased most rapidly for groups inoculated with the P and DP combination, and by 1 month after the second boost, ELISA titers were similar for all groups. The highest plaque reduction neutralization test (PRNT) titers were seen in those groups that received the DR/DR/DR combination (geometric mean titer [GMT], 510), the P/P/P vaccine (GMT, 345), the DP/DP/DP combination (GMT, 287), and the R/R/R vaccine (GMT, 200). The next highest titers were seen in animals that received the D/R/R vaccine (GMT, 186) and the D/P/P vaccine (GMT, 163). Animals that received the D/D/D vaccine had the lowest neutralizing antibody titer (GMT, 49). Both ELISA and PRNT titers declined at variable rates. The only significant protection from viremia was observed in the P-vaccinated animals (mean of 0.5 days), which also showed the highest antibody concentration, including antibodies to NS1, and highest antibody avidity at the time of challenge.
Biological and Proteolytic Variation in the Venom of Crotalus scutulatus scutulatus from Mexico.
Borja, Miguel; Neri-Castro, Edgar; Castañeda-Gaytán, Gamaliel; Strickland, Jason L; Parkinson, Christopher L; Castañeda-Gaytán, Juan; Ponce-López, Roberto; Lomonte, Bruno; Olvera-Rodríguez, Alejandro; Alagón, Alejandro; Pérez-Morales, Rebeca
2018-01-08
Rattlesnake venoms may be classified according to the presence/absence and relative abundance of the neurotoxic phospholipases A 2 s (PLA 2 s), such as Mojave toxin, and snake venom metalloproteinases (SVMPs). In Mexico, studies to determine venom variation in Mojave Rattlesnakes ( Crotalus scutulatus scutulatus ) are limited and little is known about the biological and proteolytic activities in this species. Tissue (34) and venom (29) samples were obtained from C. s. scutulatus from different locations within their distribution in Mexico. Mojave toxin detection was carried out at the genomic (by PCR) and protein (by ELISA) levels for all tissue and venom samples. Biological activity was tested on representative venoms by measuring LD 50 and hemorrhagic activity. To determine the approximate amount of SVMPs, 15 venoms were separated by RP-HPLC and variation in protein profile and proteolytic activity was evaluated by SDS-PAGE ( n = 28) and Hide Powder Azure proteolytic analysis ( n = 27). Three types of venom were identified in Mexico which is comparable to the intraspecific venom diversity observed in the Sonoran Desert of Arizona, USA: Venom Type A (∼Type II), with Mojave toxin, highly toxic, lacking hemorrhagic activity, and with scarce proteolytic activity; Type B (∼Type I), without Mojave toxin, less toxic than Type A, highly hemorrhagic and proteolytic; and Type A + B, containing Mojave toxin, as toxic as venom Type A, variable in hemorrhagic activity and with intermediate proteolytic activity. We also detected a positive correlation between SVMP abundance and hemorrhagic and proteolytic activities. Although more sampling is necessary, our results suggest that venoms containing Mojave toxin and venom lacking this toxin are distributed in the northwest and southeast portions of the distribution in Mexico, respectively, while an intergradation in the middle of both zones is present.
Biological and Proteolytic Variation in the Venom of Crotalus scutulatus scutulatus from Mexico
Castañeda-Gaytán, Gamaliel; Castañeda-Gaytán, Juan; Ponce-López, Roberto; Olvera-Rodríguez, Alejandro; Alagón, Alejandro; Pérez-Morales, Rebeca
2018-01-01
Rattlesnake venoms may be classified according to the presence/absence and relative abundance of the neurotoxic phospholipases A2s (PLA2s), such as Mojave toxin, and snake venom metalloproteinases (SVMPs). In Mexico, studies to determine venom variation in Mojave Rattlesnakes (Crotalus scutulatus scutulatus) are limited and little is known about the biological and proteolytic activities in this species. Tissue (34) and venom (29) samples were obtained from C. s. scutulatus from different locations within their distribution in Mexico. Mojave toxin detection was carried out at the genomic (by PCR) and protein (by ELISA) levels for all tissue and venom samples. Biological activity was tested on representative venoms by measuring LD50 and hemorrhagic activity. To determine the approximate amount of SVMPs, 15 venoms were separated by RP-HPLC and variation in protein profile and proteolytic activity was evaluated by SDS-PAGE (n = 28) and Hide Powder Azure proteolytic analysis (n = 27). Three types of venom were identified in Mexico which is comparable to the intraspecific venom diversity observed in the Sonoran Desert of Arizona, USA: Venom Type A (∼Type II), with Mojave toxin, highly toxic, lacking hemorrhagic activity, and with scarce proteolytic activity; Type B (∼Type I), without Mojave toxin, less toxic than Type A, highly hemorrhagic and proteolytic; and Type A + B, containing Mojave toxin, as toxic as venom Type A, variable in hemorrhagic activity and with intermediate proteolytic activity. We also detected a positive correlation between SVMP abundance and hemorrhagic and proteolytic activities. Although more sampling is necessary, our results suggest that venoms containing Mojave toxin and venom lacking this toxin are distributed in the northwest and southeast portions of the distribution in Mexico, respectively, while an intergradation in the middle of both zones is present. PMID:29316683
Palikhe, Nami Shrestha; Sin, Hye Jung; Kim, Seung Hyun; Sin, Hyun Jung; Hwang, Eui Kyung; Ye, Young Min; Park, Hae-Sim
2012-08-01
Prostaglandin E2 receptor subtype EP4 (PTGER4) is one of the four subtypes of receptors for prostaglandin E2 (PGE2). Overproduction of cysteinyl leukotriene in mast cells may be related with suppression of PGE2 in patients with aspirin hypersensitivity. Considering the association of PTGER4 in mast cells, urticaria- and aspirin-related disease, we hypothesized the genetic variability of PTGER4 may be associated with aspirin-intolerant chronic urticaria (AICU). The case-control study was performed in 141 with AICU, 153 with aspirin-tolerant chronic urticaria (ATCU) and 174 with normal controls (NCs). PTGER4 promoter single-nucleotide polymorphism was genotyped using a primer extension method with the SNAPshot ddNTP primer extension kit. The functional variability of PTGER4 promoter polymorphism was carried out by dual-luciferase system and electrophoretic mobility shift assay (EMSA) in human mast cells (HMC-1). Furthermore, the effect of aspirin was performed for PTGER4 mRNA expression using real-time PCR, and PGE2 production was checked in HMC-1 cells using ELISA. AICU patients carrying GG genotype at -1254 G>A showed significantly higher frequency compared with NC (P=0.032). Similarly, the minor allele frequency, G allele was significantly higher in AICU compared with NC (P=0.031). In vitro functional study demonstrated that the -1254 G allele had lower luciferase activity (P<0.001) in HMC-1 cells. EMSA finding showed that PTGER4 -1254 G produced a specific band. Significantly decreased PTGER4 expression (P=0.008) and PGE2 production by aspirin exposure was confirmed in in vitro HMC cell line model (P=0.001). The PTGER4 -1254 G allele demonstrated a higher frequency in AICU patients and lower promoter activity with decreased expression of PTGER4 and contributes to the development of AICU.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...
Chemiluminescent optical fiber immunosensor for the detection of anti-West Nile virus IgG.
Herrmann, Sebastien; Leshem, Boaz; Landes, Shimi; Rager-Zisman, Bracha; Marks, Robert S
2005-03-31
An ELISA-based optical fiber methodology developed for the detection of anti-West Nile virus IgG antibodies in serum was compared to standard colorimetric and chemiluminescent ELISA based on microtiter plates. Colorimetric ELISA was the least sensitive, especially at high titer dilutions. The fiber-optic immunosensor based on the same ELISA immunological rationale was the most sensitive technique.
Rapid synthesis of VX-745: p38 MAP kinase inhibition in Werner syndrome cells.
Bagley, Mark C; Davis, Terence; Dix, Matthew C; Rokicki, Michal J; Kipling, David
2007-09-15
The p38 mitogen-activated protein kinase inhibitor VX-745 is prepared rapidly and efficiently in a four-step sequence using a combination of conductive heating and microwave-mediated steps. Its inhibitory activity was confirmed in hTERT immortalized HCA2 and WS dermal fibroblasts at 0.5-1.0 microM concentration by ELISA and immunoblot assay, and displays excellent kinase selectivity over the related stress-activated kinase JNK.
La Maestra, L; Zaninoni, A; Marriott, J B; Lazzarin, A; Dalgleish, A G; Barcellini, W
2000-01-01
We investigated the in vitro effect of the water-soluble, highly stable thalidomide analogue CC-3052 on HIV-1 expression and TNF-α production in latently infected promonocytic U1 cells, acutely infected T cells and monocyte-derived human macrophages (MDM), and in mitogen-stimulated ex vivo cultures from patients with primary acute HIV-1 infection. HIV-1 expression was assessed by Northern blot analysis of RNAs, and ELISA for p24 antigen release and reverse transcriptase (RT) activity. TNF-α expression was evaluated by RT-polymerase chain reaction (PCR)-ELISA for mRNA and ELISA for protein secretion. We demonstrated that CC-3052 is able to inhibit HIV-1 expression, as evaluated by mRNA, p24 release and RT activity, in phorbol myristate acetate (PMA)- and cytokine-stimulated U1 cells. Furthermore, CC-3052 inhibited HIV-1 expression, as evaluated by p24 and RT activity, in acutely infected MDM and T cells. As far as TNF-α is concerned, CC-3052 significantly reduced TNF-α mRNA and protein secretion in PMA-stimulated U937 and U1 cells, and in PMA-stimulated uninfected and acutely infected MDM. Consistently, the addition of CC-3052 reduced TNF-α production in phytohaemagglutinin (PHA) and lipopolysaccharide (LPS)-stimulated whole blood cultures from patients during the primary acute phase of HIV-1 infection. Since TNF-α is among the most potent enhancers of HIV-1 expression, the effect of CC-3052 on TNF-α may account for its inhibitory activity on HIV-1 expression. Given the well documented immunopathological role of TNF-α and its correlation with viral load, advanced disease and poor prognosis, CC-3052 could be an interesting drug for the design of therapeutic strategies in association with anti-retroviral agents. PMID:10606973
La Maestra, L; Zaninoni, A; Marriott, J B; Lazzarin, A; Dalgleish, A G; Barcellini, W
2000-01-01
We investigated the in vitro effect of the water-soluble, highly stable thalidomide analogue CC-3052 on HIV-1 expression and TNF-alpha production in latently infected promonocytic U1 cells, acutely infected T cells and monocyte-derived human macrophages (MDM), and in mitogen-stimulated ex vivo cultures from patients with primary acute HIV-1 infection. HIV-1 expression was assessed by Northern blot analysis of RNAs, and ELISA for p24 antigen release and reverse transcriptase (RT) activity. TNF-alpha expression was evaluated by RT-polymerase chain reaction (PCR)-ELISA for mRNA and ELISA for protein secretion. We demonstrated that CC-3052 is able to inhibit HIV-1 expression, as evaluated by mRNA, p24 release and RT activity, in phorbol myristate acetate (PMA)- and cytokine-stimulated U1 cells. Furthermore, CC-3052 inhibited HIV-1 expression, as evaluated by p24 and RT activity, in acutely infected MDM and T cells. As far as TNF-alpha is concerned, CC-3052 significantly reduced TNF-alpha mRNA and protein secretion in PMA-stimulated U937 and U1 cells, and in PMA-stimulated uninfected and acutely infected MDM. Consistently, the addition of CC-3052 reduced TNF-alpha production in phytohaemagglutinin (PHA) and lipopolysaccharide (LPS)-stimulated whole blood cultures from patients during the primary acute phase of HIV-1 infection. Since TNF-alpha is among the most potent enhancers of HIV-1 expression, the effect of CC-3052 on TNF-alpha may account for its inhibitory activity on HIV-1 expression. Given the well documented immunopathological role of TNF-alpha and its correlation with viral load, advanced disease and poor prognosis, CC-3052 could be an interesting drug for the design of therapeutic strategies in association with anti-retroviral agents.
Udomsin, Orapin; Krittanai, Supaluk; Kitisripanya, Tharita; Tanaka, Hiroyuki; Putalun, Waraporn
2017-01-01
Background: Puerarin (PUE) is a phytoestrogen found in Pueraria candollei and Pueraria lobata. These plants are substantial for traditional medicine in various Asian countries. PUE is a key marker that can be found only in the Pueraria species. Objective: To establish the method for determination of PUE content which is required for quality control of pharmaceutical products. Materials and Methods: PUE-cationized bovine serum albumin conjugate was created via Mannich reaction. After the rabbit immunization, the obtain anti-PUE polyclonal antibody (PAb) was used to develop an enzyme-linked immunosorbent assay (ELISA). Results: An anti-PUE PAb possess a great sensitivity and specificity. The cross-reactivity analysis shows no cross-reaction of an established antibody against other substances. In addition, we successfully developed an indirect competitive ELISA (icELISA) for the quantitative analysis of PUE. The result of method validation conforms to acceptance criteria and correlates with high-performance liquid chromatography, the reference method. The icELISA was applied to determine PUE content in Pueraria spp. plant samples and its derived pharmaceutical products. Conclusion: This highly specific immunogen was created from the Mannich reaction. An icELISA can also be applied to other research propose in the further studies. SUMMARY The new immunogen conjugated (puerarin-cBSA) via Mannich reaction was successfully in rising of antibody against puerarin (PUE)The obtained anti-PUE polyclonal antibody (PAb) was high sensitivity and specificity to PUEAn indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed and validated using anti-PUE PAbThe established icELISA was applied to determine PUE content in various tuberous root of Pueraria sppMoreover, icELISA method can be applicable in Pueraria spp. derived products. Abbreviations used: PUE: Puerarin; PAb: Polyclonal antibody; ELISA: Enzyme-linked immunosorbent assay; icELISA: Indirect competitive ELISA; cBSA: Cationized bovine serum albumin. PMID:29491643
Ito, Kaori; Yamamoto, Takayuki; Oyama, Yuriko; Tsuruma, Rieko; Saito, Eriko; Saito, Yoshikazu; Ozu, Takeshi; Honjoh, Tsutomu; Adachi, Reiko; Sakai, Shinobu; Akiyama, Hiroshi; Shoji, Masahiro
2016-09-01
Enzyme-linked immunosorbent assay (ELISA) is commonly used to determine food allergens in food products. However, a significant number of ELISAs give an erroneous result, especially when applied to highly processed food. Accordingly, an improved ELISA, which utilizes an extraction solution comprising the surfactant sodium lauryl sulfate (SDS) and reductant 2-mercaptoethanol (2-ME), has been specially developed to analyze food allergens in highly processed food by enhancing analyte protein extraction. Recently, however, the use of 2-ME has become undesirable. In the present study, a new extraction solution containing a human- and eco-friendly reductant, which is convenient to use at the food manufacturing site, has been established. Among three chemicals with different reducing properties, sodium sulfite, tris(3-hydroxypropyl)phosphine, and mercaptoethylamine sodium sulfite was selected as a 2-ME substitute. The protein extraction ability of SDS/0.1 M sodium sulfite solution was comparable to that of SDS/2-ME solution. Next, the ELISA performance for egg, milk, wheat, peanut, and buckwheat was evaluated by using model-processed foods and commercially available food products. The data showed that the SDS/0.1 M sulfite ELISA significantly correlated with the SDS/2-ME ELISA for all food allergens examined (p < 0.01), thereby establishing the validity of the SDS/0.1 M sulfite ELISA performance. Furthermore, the new SDS/0.1 M sulfite solution was investigated for its applicability to the lateral-flow (LF) test. The result demonstrated the successful analysis of food allergens in processed food, showing consistency with the SDS/0.1 M sulfite ELISA results. Accordingly, a harmonized analysis system for processed food comprising a screening LF test and a quantitative ELISA with identical extraction solution has been established. The ELISA based on the SDS/0.1 M sulfite extraction solution has now been authorized as the revised official method for food allergen analysis in Japan.
ELISA for sulfonamides and its application for screening in water contamination.
Shelver, Weilin L; Shappell, Nancy W; Franek, Milan; Rubio, Fernando R
2008-08-13
Two enzyme-linked immunosorbent assays (ELISAs) were tested for their suitability for detecting sulfonamides in wastewater from various stages in wastewater treatment plants (WWTPs), the river into which the wastewater is discharged, and two swine-rearing facilities. The sulfamethoxazole ELISA cross-reacts with several compounds, achieving detection limits of <0.04 microg/L for sulfamethoxazole (SMX), sulfamethoxypyridine, sulfachloropyridine, and sulfamethoxine, whereas the sulfamethazine (SMZ) ELISA is more compound specific, with a detection limit of <0.03 microg/L. Samples from various stages of wastewater purifications gave 0.6-3.1 microg/L by SMX-ELISA, whereas river samples were approximately 10-fold lower, ranging from below detection to 0.09 microg/L. Swine wastewater samples analyzed by the SMX-ELISA were either at or near detectable limits from one facility, whereas the other facility had concentrations of approximately 0.5 microg/L, although LC-MS/MS did not confirm the presence of SMX. Sulfamethazine ELISA detected no SMZ in either WWTP or river samples. In contrast, wastewater samples from swine facilities analyzed by SMZ-ELISA were found to contain approximately 30 microg/L [piglet (50-100 lb) wastewater] and approximately 7 microg/L (market-weight hog wastewater). Sulfamethazine ELISA analyses of wastewater from another swine facility found concentrations to be near or below detection limits. A solid phase extraction method was used to isolate and concentrate sulfonamides from water samples prior to LC-MS/MS multiresidue confirmatory analysis. The recoveries at 1 microg/L fortification ranged from 42 +/- 4% for SMZ to 88 +/- 4% for SMX ( n = 6). The ELISA results in the WWTPs were confirmed by LC-MS/MS, as sulfonamide multiresidue confirmatory analysis identified SMX, sulfapyridine, and sulfasalazine to be present in the wastewater. Sulfamethazine presence at one swine-rearing facility was also confirmed by LC-MS/MS, demonstrating the usefulness of the ELISA technique as a rapid and high-throughput screening method.
Salgado, Miguel; Kruze, Juan; Collins, Michael T
2007-01-01
Fecal culture has been the primary method used to diagnose paratuberculosis in goats. It is laborious, slow, and expensive. Validation of enzyme-linked immunosorbent assays (ELISAs) on milk samples could make paratuberculosis testing more widely available for goat farmers. The aim of this study was to determine the accuracy of serum and milk ELISAs for paratuberculosis, relative to fecal culture, in Chilean dairy goats. Eight dairy goat herds were selected. Feces, blood, and milk samples were collected from all female goats >2 years old. Fecal samples were cultured using Herrold egg yolk medium with mycobactin J and antibiotics. Serum and milk samples were tested using a commercial ELISA kit for Mycobacterium avium subsp. paratuberculosis antibody detection. A total of 383 goats were tested by ELISA and fecal culture. The sensitivity of ELISA on serum and milk relative to fecal culture was 74.3% (95% CI: 59.8-88.8) and 60% (95% CI: 43.8-76.2), respectively. The corresponding values for ELISA specificity based on the percentage of non- M. avium subsp. paratuberculosis-infected goats testing ELISA-negative were 98.6% (95% CI: 96.6-100) and 99.3% (95% CI: 97.9-100) on serum and milk, respectively. Proportions of positive results for serum and fecal samples were significantly different, whereas the proportions of positive results for milk and fecal samples were not significantly different. The milk ELISA had a moderate level of agreement with fecal culture results (Kappa = 0.57). The paratuberculosis ELISA on goat milk samples may be a cost-effective, accurate alternative to fecal culture.
Evaluation of commercial ELISA kits for the detection of antibodies against bluetongue virus.
Niedbalski, W
2011-01-01
The aim of this study was to estimate the diagnostic value of different commercially available ELISA kits for the detection of bluetongue virus (BTV) antibodies in infected and vaccinated animals. The relative specificity of ELISA kits was evaluated using a panel of sera originating from healthy cattle, never vaccinated nor exposed to BTV. All ELISA kits applied had a high relative specificity (99.3 - 100%). The relative sensitivity of ELISA kits assessed using a panel of sera collected from BTV infected cattle was also high and similar for all the kits (97.3 - 100%). However, the relative sensitivity evaluated on the basis of testing vaccinated animals was different: the highest sensitivity was found for Ingenasa, PrioCHECK and ID VET ELISAs (96.5 - 98.3%). Slightly lower sensitivity was calculated for Pourquier and LSI kits (82.8% and 85.4%, respectively) and much lower sensitivity was found for VMRD ELISA kit (69.5%). The repeatability of BTV ELISA kits was expressed as a coefficient of variation (CV) of results of sera tested 5 times in the same day and in different days by the period of 2 months, by the same person, in the same conditions, and by using the same equipment. The CVs of sera tested in all ELISA kits ranged from 6.1 to 9.8% and were below 10% threshold adopted as a maximum for the acceptable repeatability of the method. In conclusion, it can be stated that the applied ELISA kits can be a valuable diagnostic tool for the serological monitoring studies in the BTV contaminated premises. All the methods are very specific and sensitive when testing BTV infected animals. Nevertheless, the Ingenasa and PrioCHECK can be the most useful in sero-surveillance of livestock following vaccination.
Takeuchi, Masahiro; Doi, Tomomitsu; Obayashi, Kunie; Hirai, Ayako; Yoneda, Kazue; Tanaka, Fumihiro; Iwai, Yoshiko
2018-04-01
PD-L1 is one of the important immune checkpoint molecules that can be targeted by cancer immunotherapies. PD-L1 has a soluble form (sPD-L1) and a membrane-bound form (mPD-L1). Conventional enzyme-linked immunosorbent assay (ELISA) systems can detect sPD-L1 using anti-PD-L1 capture antibody through the antigen-antibody reaction, but cannot evaluate the quality and function of sPD-L1. In this study, we developed a novel ELISA system for the detection and quantification of sPD-L1 with PD-1-binding capacity (bsPD-L1). To capture bsPD-L1 through the ligand-receptor reaction, the anti-PD-L1 capture antibody in the conventional ELISA was replaced with PD-1-Ig fusion protein in the new ELISA. The new ELISA could detect bsPD-L1 in 29 out of 75 plasma samples from patients with non-small cell lung cancer (NSCLC), with higher sensitivity and frequency than the conventional ELISA. The western blot analysis showed that sPD-L1 in the plasma was glycosylated. Treatment of the samples with glycosidase reduced the absorbance determined by the new ELISA but had no effect on the absorbance determined by the conventional ELISA. These results suggest that glycosylation of sPD-L1 is important for its binding to the immobilized PD-1 in the new ELISA. Our new ELISA system may be useful for the evaluation of functional sPD-L1 with PD-1-binding capacity in cancer patients. Copyright © 2018 European Federation of Immunological Societies. Published by Elsevier B.V. All rights reserved.
Walraph, J; Zoche-Golob, V; Weber, J; Freick, M
2018-06-01
In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
Cubero, África; Durántez, Carlos; Almaraz, Ana; Fernández-Lago, Luis; Gutiérrez, María P; Castro, María J; Bratos, Miguel A; Simarro, María; March, Gabriel A; Orduña, Antonio
2018-04-01
The aim of this work was to ascertain the usefulness of a new commercially-available single-assay chemiluminescence test (CHT) for the diagnosis of human tularemia (Tularaemia VIRCLIA IgG + IgM monotest, Vircell, Santa Fe, Granada, Spain). A total of 773 sera from 773 patients including 364 initial sera from patients with diagnosed tularemia, patients with suspected tularemia not confirmed (100), healthy people (152), patients with serology positive to Brucella (97), patients diagnosed with other infectious diseases (30), and patients diagnosed with autoimmune diseases (30) were included. All sera were tested by CHT, "in-house" microagglutination test (MAT), immunochromatographic test (ICT) (Virapid Tularaemia, Vircell, Santa Fe Granada, Spain), and "in-house" ELISA IgG, and ELISA IgM. Of the total initial sera, 334 (sensitivity 91.8%) were positive in the CHT, 332 (sensitivity 91.2%) in the MAT, 330 (sensitivity 90.7%) in the ICT, and 328 (sensitivity 90.1%) in the ELISA IgG and ELISA IgM tests. The specificity of the CHT was 96.7%; of the MAT, 100%; of the ICT, 98.7%; and of the ELISA IgG and ELISA IgM, 97.4%. In the group of patients with serology positive to Brucella, at least 12.4% of sera were positive in tularemia tests (12.4% in ELISA IgM, 13.4% in MAT, 14.4% in ICT, and 15.5% in CHT and ELISA IgG). In conclusion, CHT presents a sensitivity and specificity in early diagnosis of human tularemia, similar to MAT, ICT, and ELISA IgG and ELISA IgM. Its single assay design allows lower costs, especially in areas of low endemicity or inter-epidemic periods.
Novel enzymatic method for assaying Lp-PLA2 in serum.
Yamaura, Saki; Sakasegawa, Shin-Ichi; Koguma, Emisa; Ueda, Shigeru; Kayamori, Yuzo; Sugimori, Daisuke; Karasawa, Ken
2018-06-01
Measurement of lipoprotein-associated phospholipase A 2 (Lp-PLA 2 ) can be used as an adjunct to traditional cardiovascular risk factors for identifying individuals at higher risk of cardiovascular events. This can be performed by quantification of the protein concentration using an ELISA platform or by measuring Lp-PLA 2 activity using platelet-activating factor (PAF) analog as substrate. Here, an enzymatic Lp-PLA 2 activity assay method using 1-O-Hexadecyl-2-acetyl-rac-glycero-3-phosphocholine (rac C 16 PAF) was developed. The newly revealed substrate specificity of lysoplasmalogen-specific phospholipase D (lysophospholipase D (LysoPLD)) was exploited. Lp-PLA 2 hydrolyzes 1-O-Hexadecyl-2-acetyl-sn-glycero-3-phosphocholine (C 16 PAF) to 1-O-Hexadecyl-2-hydroxy-sn-glycero-3-phosphocholine (LysoPAF). LysoPLD acted on LysoPAF, and the hydrolytically released choline was detected by choline oxidase. Regression analysis of Lp-PLA 2 activity measured by the enzymatic Lp-PLA 2 activity assay vs. two chemical Lp-PLA 2 activity assays, i.e. LpPLA 2 FS and PLAC® test, and ELISA, gave the following correlation coefficients: 0.990, 0.893 and 0.785, respectively (n = 30). Advantages of this enzymatic Lp-PLA 2 activity assay compared with chemical Lp-PLA 2 methods include the following; (i) only requires two reagents enabling a simple two-point linear calibration method with one calibrator (ii) no need for inhibitors of esterase-like activity in serum. Copyright © 2018 Elsevier B.V. All rights reserved.
Carbamylated albumin is one of the target antigens of anti-carbamylated protein antibodies.
Nakabo, Shuichiro; Hashimoto, Motomu; Ito, Shinji; Furu, Moritoshi; Ito, Hiromu; Fujii, Takao; Yoshifuji, Hajime; Imura, Yoshitaka; Nakashima, Ran; Murakami, Kosaku; Kuramoto, Nobuo; Tanaka, Masao; Satoh, Junko; Ishigami, Akihito; Morita, Satoshi; Mimori, Tsuneyo; Ohmura, Koichiro
2017-07-01
Anti-carbamylated protein (anti-CarP) antibodies are detected in RA patients. Fetal calf serum is used as an antigen source in anti-CarP ELISA, and the precise target antigens have not been found. We aimed to identify the target antigens of anti-CarP antibodies. Western blotting of anti-CarP antibodies was conducted. Anti-carbamylated human albumin (CarALB) antibody was detected by in-house ELISA for 493 RA patients and 144 healthy controls (HCs). An inhibition ELISA of anti-CarP antibodies by CarALB and citrullinated albumin (citALB) was performed using eight RA patients' sera. Serum CarALB was detected by liquid chromatography-tandem mass spectroscopy (LC/MS/MS), and the serum MPO concentration was measured by ELISA. We focused on carbamylated albumin because it corresponded to the size of the thickest band detected by western blotting of anti-CarP antibodies. Anti-CarALB antibody was detected in 31.4% of RA patients, and the correlation of the titres between anti-CarALB and anti-CarP was much closer than that between anti-citALB and anti-CCP antibodies (ρ = 0.59 and ρ = 0.16, respectively). The inhibition ELISA showed that anti-CarP antibodies were inhibited by CarALB, but not by citALB. CarALB was detected in sera from RA patients by LC/MS/MS. The serum MPO concentration was correlated with disease activity and was higher in RA patients with anti-CarALB antibody than in those without. We found that carbamylated albumin is a novel target antigen of anti-CarP antibodies, and it is the first reported target antigen that has not been reported as the target of ACPA. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Tahk, Hongmin; Lee, Min Hwa; Lee, Kang Bum; Cheon, Doo-Sung; Choi, Changsun
2011-07-01
This study aimed to develop a specific and sensitive duplex reverse transcription polymerase chain reaction enzyme-linked immunosorbent assay (duplex RT-PCR-ELISA) for hepatitis A virus (HAV) and hepatitis E virus (HEV). Duplex RT-PCR-ELISA could detect and differentiate HAV and HEV with specific probes. When ELISA technique was used to detect probe-bound RT-PCR products, duplex RT-PCR-ELISA could detect as little as 0.1 ng/μL HAV and HEV from clinical samples. Human norovirus, enterovirus, poliovirus, murine norovirus and feline calicivirus were used for the specificity test; all were negative. Therefore duplex RT-PCR-ELISA can be used for the simultaneous detection of HAV and HEV in contaminated fecal samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Microchip ELISA coupled with cell phone to detect ovarian cancer HE4 biomarker in urine.
Wang, ShuQi; Akbas, Ragip; Demirci, Utkan
2015-01-01
Ovarian cancer is a leading cause of death from gynecologic cancers in the USA, and early diagnosis can potentially increase 5-year survival rate. Detection of biomarkers derived from hyperplasia of epithelial tissue by enzyme-linked immunosorbent assay (ELISA) proves to be a practical way of early diagnosis of ovarian cancer. However, ELISA is commonly performed in a laboratory setting, and it cannot be used in a clinical setting for on-site consultation. We have shown a microchip ELISA that detects HE4, an ovarian cancer biomarker, from urine using a cell phone integrated with a mobile application for imaging and data analysis. In microchip ELISA, HE4 from urine was first absorbed on the surface; the primary and secondary antibodies were subsequently anchored on the surface via immuno-reaction; and addition of substrate led to color development because of enzymatic labeling. The microchip after color development was imaged using a cell phone, and the color intensity was analyzed by an integrated mobile application. By comparing with an ELISA standard curve, the concentration of HE4 was reported on the cell phone screen. The presented microchip ELISA coupled with a cell phone is portable as opposed to traditional ELISA, and this method can facilitate the detection of ovarian cancer at the point-of-care (POC).
Liu, Shuangshuang; Li, Shasha; Zhang, Yang; Wang, Ye; Zhu, Yumeng; Wang, Bin; Chen, Zhi-Nan
2017-01-01
The immunoglobulin superfamily member CD147 is a widely expressed glycoprotein that occurs in both a membrane-spanning and soluble form. Sandwich ELISA is a powerful tool for analyzing soluble antigens. The aim of the present study was to obtain a highly specific polyclonal antibody against human CD147 that can be used for sandwich ELISA analysis. Expression of recombinant CD147 by a eukaryotic expression system was used to immunize rabbits to obtain antiserum. A highly specific polyclonal antibody that was able to detect soluble CD147 in sandwich ELISA was obtained by antigen-immunoaffinity chromatography purification. The purity of rabbit anti-CD147 polyclonal antibodies was ~99%, and ELISA analysis was able to determine the titer of the rabbit anti-CD147 polyclonal antibodies at 1:512,000. The lowest concentration of the standard CD147 antigen that the sandwich ELISA was able to detect was 31.25 pg/ml. The sandwich ELISA system was composed of anti-hepatoma HAb18 monoclonal antibodies and purified rabbit anti-CD147 polyclonal antibodies. The present study demonstrated that antigen-immunoaffinity chromatography may be a good technique for the purification of polyclonal antibodies, which may be used to detect antigen in sandwich ELISAs. PMID:28487989
Aga, D.S.; Thurman, E.M.
1993-01-01
Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were coupled for automated trace analysis of pristine water samples containing 2-chloro-4-ethylamino-6-isopropylamine-s-triazine (atrazine) and 2-chloro-2???,6???-diethyl-N-(methoxymethyl)acetanilide (alachlor). The isolation of the two herbicides on a C18-resin involved the selection of an elution solvent that both removes interfering substances and is compatible with ELISA. Ethyl acetate was selected as the elution solvent followed by a solvent exchange with methanol/water (20/80, % v/v). The SPE-ELISA method has a detection limit of 5.0 ng/L (5 ppt), >90% recovery, and a relative standard deviation of ??10%. The performance of a microtiter plate-based ELISA and a magnetic particle-based ELISA coupled to SPE was also evaluated. Although the sensitivity of the two ELISA methods was comparable, the precision using magnetic particles was improved considerably (??10% versus ??20%) because of the faster reaction kinetics provided by the magnetic particles. Finally, SPE-ELISA and isotope dilution gas chromatography/ mass spectrometry correlated well (correlation coefficient of 0.96) for lake-water samples. The SPE-ELISA method is simple and may have broader applications for the inexpensive automated analysis of other contaminants in water at trace levels.
Comparison of ELISA and Microscopy for detection of Cryptosporidium in stool
Sharma, Madhu; Chaudhary, Uma; Yadav, Aparna
2014-01-01
Background: Cryptosporidiosis, a diarrheal disease caused by the protozoan parasite Cryptosporidium spp. has become recognized as one of the most common causes of water borne diseases in humans. Aims and Objectives: To compare the sensitivity of ELISA and Microscopy for detection of Cryptosporidium in stool samples Materials and Methods: The study was conducted in the Department of Microbiology of PT. B.D. Sharma PGIMS Rohtak, between January 2011 to june 2011 on 50 stool samples, which were processed for detection of cryptosporidial antigen by ELISA and detection of cysts by microscopy (Modified Ziehl and Nelsen staining). Study and Design: This was a prospective study conducted in the Department of Microbiology in PT. BD Sharma, PGIMS, Rohtak, India. Result: Out of total, 50 stool samples eighteen (36%) samples were found positive for Cryptosporidium cysts by microscopy in comparison to 3(6%) stool samples which were found positive for cryptosporidial antigen by ELISA. Samples found positive with ELISA were also positive with microscopy. Sensitivity, specificity, positive predictive value and negative predictive value for ELISA was 16.7%, 100%, 100% and 68% respectively. Conclusion: The study concludes that stool microscopic Modified acid fast staining is more sensitive method than ELISA for detection of Cryptosporidium in stool samples but the specificity of ELISA was more than microscopy. PMID:25584216
Chiodini, P L; Hartley, S; Hewitt, P E; Barbara, J A; Lalloo, K; Bligh, J; Voller, A
1997-01-01
Blood donations are often wasted for lack of a satisfactory procedure to evaluate donors potentially exposed to malaria. We evaluated a commercial ELISA for the detection of antibodies to malaria and compared it with an immunofluorescent antibody test (IFAT). When 5,311 sera from routine non-exposed donors were tested, 24 (0.45%) were positive by the ELISA, using a Plasmodium falciparum antigen. Seventeen were subjected to confirmatory testing but none were positive by IFAT. Of 1,000 donors potentially exposed in endemic areas 15 (1.5%) were repeatably reactive by ELISA. 10 of these were tested by IFAT and 2 were positive. When 150 patients attending the Hospital for Tropical Diseases in London with acute malaria were tested, 73% of those infected with P. falciparum were repeatably reactive for malarial antibodies by ELISA and 56% with Plasmodium vivax. Of 88 stored clinical sera tested by both IFAT and ELISA 56 were positive by IFAT and of these 52 (93 degrees/0) were positive by ELISA. The ELISA is sufficiently sensitive and specific to screen at-risk donors. Its use could safely retrieve 40,000 red cell units currently discarded each year in Great Britain.
Detection of Fusarium verticillioides by PCR-ELISA based on FUM21 gene.
Omori, Aline Myuki; Ono, Elisabete Yurie Sataque; Bordini, Jaqueline Gozzi; Hirozawa, Melissa Tiemi; Fungaro, Maria Helena Pelegrinelli; Ono, Mario Augusto
2018-08-01
Fusarium verticillioides is a primary corn pathogen and fumonisin producer which is associated with toxic effects in humans and animals. The traditional methods for detection of fungal contamination based on morphological characteristics are time-consuming and show low sensitivity and specificity. Therefore, the objective of this study was to develop a PCR-ELISA based on the FUM21 gene for F. verticillioides detection. The DNA of the F. verticillioides, Fusarium sp., Aspergillus sp. and Penicillium sp. isolates was analyzed by conventional PCR and PCR-ELISA to determine the specificity. The PCR-ELISA was specific to F. verticillioides isolates, showed a 2.5 pg detection limit and was 100-fold more sensitive than conventional PCR. In corn samples inoculated with F. verticillioides conidia, the detection limit of the PCR-ELISA was 1 × 10 4 conidia/g and was also 100-fold more sensitive than conventional PCR. Naturally contaminated corn samples were analyzed by PCR-ELISA based on the FUM21 gene and PCR-ELISA absorbance values correlated positively (p < 0.05) with Fusarium sp. counts (CFU/g). These results suggest that the PCR-ELISA developed in this study can be useful for F. verticillioides detection in corn samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shinozaki, Takashi; Watanabe, Ryuichi; Kawatsu, Kentaro; Sakurada, Kiyonari; Takahi, Shinya; Ueno, Ken-ichi; Matsushima, Ryoji; Suzuki, Toshiyuki
2013-01-01
We investigated the applicability of enzyme-linked immunosorbent assay (PSP-ELISA) using a monoclonal antibody against paralytic shellfish toxins (PST) for screening oysters collected at several coastal areas in Kumamoto prefecture, Japan. Oysters collected between 2007 and 2010 were analyzed by PSP-ELISA. As an alternative calibrant, a naturally contaminated oyster extract was used to quantify toxins in the oyster samples. The toxicity of the calibrant oyster extract determined by the official testing method, mouse bioassay (MBA), was 4 MU/g. Oyster samples collected over 3 years showed a similar toxin profile to the alternative standard, resulting in good agreement between the PSP-ELISA and the MBA. The PSP-ELISA method was better than the MBA in terms of sensitivity, indicating that it may be useful for earlier warning of contamination of oysters by PST in the distinct coastal areas. To use the PSP-ELISA as a screening method prior to MBA, we finally set a screening level at 2 MU/g PSP-ELISA for oyster monitoring in Kumamoto prefecture. We confirmed that there were on samples exceeding the quarantine level (4 MU/g) in MBA among samples quantified as below the screening level by the PSP-ELISA. It was concluded that the use of PSP-ELISA could reduce the numbers of animals needed for MBA testing.
Analysis of High-Throughput ELISA Microarray Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, Amanda M.; Daly, Don S.; Zangar, Richard C.
Our research group develops analytical methods and software for the high-throughput analysis of quantitative enzyme-linked immunosorbent assay (ELISA) microarrays. ELISA microarrays differ from DNA microarrays in several fundamental aspects and most algorithms for analysis of DNA microarray data are not applicable to ELISA microarrays. In this review, we provide an overview of the steps involved in ELISA microarray data analysis and how the statistically sound algorithms we have developed provide an integrated software suite to address the needs of each data-processing step. The algorithms discussed are available in a set of open-source software tools (http://www.pnl.gov/statistics/ProMAT).
Ragupathi, Govind; Koide, Fusataka; Sathyan, Natarajan; Kagan, Ella; Spassova, Maria; Bornmann, William; Gregor, Polly; Reis, Celso A; Clausen, Henrik; Danishefsky, Samuel J; Livingston, Philip O
2003-10-01
Previously using a series of monovalent vaccines, we demonstrated that the optimal method for inducing an antibody response against cancer cell-surface antigens is covalent conjugation of the antigens to keyhole limpet hemocyanin (KLH) and the use of a saponin adjuvant. We have prepared a heptavalent-KLH conjugate vaccine containing the seven epithelial cancer antigens GM2, Globo H, Lewis(y), TF(c), Tn(c), STn(c), and glycosylated MUC1. In preparation for testing this vaccine in the clinic, we tested the impact on antibody induction of administering the individual conjugates plus adjuvant compared with a mixture of the seven conjugates plus adjuvant, and of several variables thought to augment immunogenicity. These include approaches for decreasing suppressor cell activity or increasing helper T-lymphocyte activity (low dose cyclophosphamide or anti-CTLA-4 MAb), different saponin adjuvants at various doses (QS-21 and GPI-0100), and different methods of formulation (lyophilization and use of polysorbate 80). We find that: (1). Immunization with the heptavalent-KLH conjugate plus GPI-0100 vaccine induces antibodies against the seven antigens of comparable titer to those induced by the individual-KLH conjugate vaccines, high titers of antibodies against Tn (median ELISA titer IgM/IgG 320/10240), STn (640/5120), TF (320/10240), MUC1 (80/20480), and globo H (640/40); while lower titers of antibodies against Lewis(y)()(160/0) and only occasional antibodies against GM2 are induced. (2). These antibodies reacted with the purified synthetic antigens by ELISA, and with naturally expressed antigens on the cancer cell surface by FACS. (3). None of the approaches for further altering the suppressor cell/helper T-cell balance nor changes to the standard formulation by lyophilization or use of polysorbate 80 had any impact on antibody titers. (4). An optimal dose of saponin adjuvant, QS-21 (50 microg) or GPI-0100 (1000 microg), is required for optimal antibody titers. This heptavalent vaccine is sufficiently optimized for testing in the clinic.
Yan, B; Ma, J-Z; Yu, T-F; Shao, S-L; Li, M; Fan, X-D
2014-12-01
The aim of this study was to develop an indirect enzyme-linked immunosorbent assay (i-ELISA) based on epitope AA503-509 (RANEPKE), which is on nonstructural protein of Muscovy duck parvovirus (MDPV). Sera (100) from negative and vaccinated Muscovy ducks were compared with infected sera (240) to establish the cut-off value of this i-ELISA. There was a significant difference between the positive and negative populations (P < 0·05). The adoption of this positive-negative threshold value for this i-ELISA assay resulted in specificity of 98·0%. This i-ELISA could be used as a diagnostic tool for differentiating infected Muscovy ducks from Muscovy ducks vaccinated with inactivated virus. In this study, we developed an i-ELISA based on epitope AA503-509 (RANEPKE), which is on nonstructural protein of MDPV. This i-ELISA could be used as a diagnostic tool for differentiating infected Muscovy ducks from Muscovy ducks vaccinated with inactivated virus. © 2014 The Society for Applied Microbiology.
Constraining stellar binary black hole formation scenarios with eLISA eccentricity measurements
NASA Astrophysics Data System (ADS)
Nishizawa, Atsushi; Sesana, Alberto; Berti, Emanuele; Klein, Antoine
2017-03-01
A space-based interferometer such as the evolved Laser Interferometer Space Antenna (eLISA) could observe a few to a few thousands of progenitors of black hole binaries (BHBs) similar to those recently detected by Advanced LIGO. Gravitational radiation circularizes the orbit during inspiral, but some BHBs retain a measurable eccentricity at the low frequencies where eLISA is the most sensitive. The eccentricity of a BHB carries precious information about its formation channel: BHBs formed in the field, in globular clusters, or close to a massive black hole (MBH) have distinct eccentricity distributions in the eLISA band. We generate mock eLISA observations, folding in measurement errors, and using a Bayesian model selection, we study whether eLISA measurements can identify the BHB formation channel. We find that a handful of observations would suffice to tell whether BHBs were formed in the gravitational field of an MBH. Conversely, several tens of observations are needed to tell apart field formation from globular cluster formation. A 5-yr eLISA mission with the longest possible armlength is desirable to shed light on BHB formation scenarios.
Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D
2008-10-01
Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.
Collins, Á B; Grant, J; Barrett, D; Doherty, M L; Hallinan, A; Mee, J F
2017-08-01
Schmallenberg virus (SBV) is transmitted by Culicoides spp. biting midges and can cause abortions and congenital malformations in ruminants and milk drop in dairy cattle. Estimating true within-herd seroprevalence is an essential component of efficient and cost-effective SBV surveillance programs. The objectives of this study were: (1) determine the correlation between bulk-tank milk (BTM)-ELISA results and within-herd seroprevalence, (2) evaluate the ability of BTM-ELISA results to predict within-herd seroprevalence and (3) explore the distributions of individual animal serology results using novel statistical methodology. BTM samples (n=24) and blood samples (n=4019) collected from all lactating cows contributing to the BTM in 26 Irish dairy herds (58-444 cows/herd) in 2014 located in a region exposed to SBV in 2012/2013, were analysed for SBV-specific antibodies using IDVet ® ELISA kits. The correlation between BTM-ELISA results and within-herd seroprevalence was determined by calculating Pearson's correlation coefficient. Linear regression models were used to assess the ability of BTM-ELISA results to predict within-herd seroprevalence. The distributions of individual animal serology results were explored by determining the empirical distribution functions (EDF) of the individual animal serum ELISA results in each herd. EDFs were compared pairwise across herds, using the Kolmogorov-Smirnov statistical test. Herds with similar BTM-ELISA results, herds with similar within-herd seroprevalence and herds with similar mean-herd serology ELISA results were stratified in order to explore their respective paired-herd EDF comparisons. Statistical significance was set at p<0.05. Twenty-two herds were BTM-ELISA-positive (within-herd seroprevalence 30.6-100%) and two herds were BTM-ELISA-negative (within-herd seroprevalence 10.7 and 16.2%) indicating BTM-ELISA-negative herds can have seropositive animals present. BTM-ELISA results were highly correlated (r=0.807, p<0.0001) with, and predictive of (R 2 =0.832, p<0.0001) of within-herd seroprevalence. Predictions were most accurate for upper-range BTM-ELISA antibody titres, while they were less accurate at higher and lower antibody titres. This is likely a result of the overall high within-herd seroprevalence. In herds with similar BTM-ELISA results 82% of the paired-herd EDF comparisons were significantly different. In herds with similar within-herd seroprevalence and in herds with similar mean-herd serology ELISA results, 46% and 47% of the paired-herd EDF comparisons were significantly different, respectively. These results demonstrate that BTM antibody titres are highly predictive of within-herd seroprevalence in an SBV exposed region. Furthermore, exploring the serum EDFs revealed that the variation observed in the predicted within-herd seroprevalence in the regression models is likely a result of individual animal variation in serum antibody titres in these herds. Copyright © 2017 Elsevier B.V. All rights reserved.
Greibe, Eva; Nexo, Ebba
2011-11-01
Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.
Biggar, Kyle K; Storey, Kenneth B
2018-01-01
In many cases, the DNA-binding activity of a transcription factor does not change, while its transcriptional activity is greatly influenced by the make-up of bound proteins. In this study, we assessed the protein composition and DNA-binding ability of the E2F transcription factor complex to provide insight into cell cycle control in an anoxia tolerant turtle through the use of a modified ELISA protocol. This modification also permits the use of custom DNA probes that are tailored to a specific DNA binding region, introducing the ability to design capture probes for non-model organisms. Through the use of EMSA and ELISA DNA binding assays, we have successfully determined the in vitro DNA binding activity and complex dynamics of the Rb/E2F cell cycle regulatory mechanisms in an anoxic turtle, Trachemys scripta elegans . Repressive cell cycle proteins (E2F4, Rb, HDAC4 and Suv39H1) were found to significantly increase at E2F DNA-binding sites upon anoxic exposure in anoxic turtle liver. The lack of p130 involvement in the E2F DNA-bound complex indicates that anoxic turtle liver may maintain G 1 arrest for the duration of stress survival.
Biggar, Kyle K.
2018-01-01
In many cases, the DNA-binding activity of a transcription factor does not change, while its transcriptional activity is greatly influenced by the make-up of bound proteins. In this study, we assessed the protein composition and DNA-binding ability of the E2F transcription factor complex to provide insight into cell cycle control in an anoxia tolerant turtle through the use of a modified ELISA protocol. This modification also permits the use of custom DNA probes that are tailored to a specific DNA binding region, introducing the ability to design capture probes for non-model organisms. Through the use of EMSA and ELISA DNA binding assays, we have successfully determined the in vitro DNA binding activity and complex dynamics of the Rb/E2F cell cycle regulatory mechanisms in an anoxic turtle, Trachemys scripta elegans. Repressive cell cycle proteins (E2F4, Rb, HDAC4 and Suv39H1) were found to significantly increase at E2F DNA-binding sites upon anoxic exposure in anoxic turtle liver. The lack of p130 involvement in the E2F DNA-bound complex indicates that anoxic turtle liver may maintain G1 arrest for the duration of stress survival. PMID:29770276
Digital Assays Part II: Digital Protein and Cell Assays.
Basu, Amar S
2017-08-01
A digital assay is one in which the sample is partitioned into many containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, . . .). A powerful technique in the biologist's toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotype and phenotype. Where part I of this review focused on the fundamentals of partitioning and digital PCR, part II turns its attention to digital protein and cell assays. Digital enzyme assays measure the kinetics of single proteins with enzymatic activity. Digital enzyme-linked immunoassays (ELISAs) quantify antigenic proteins with 2 to 3 log lower detection limit than conventional ELISA, making them well suited for low-abundance biomarkers. Digital cell assays probe single-cell genotype and phenotype, including gene expression, intracellular and surface proteins, metabolic activity, cytotoxicity, and transcriptomes (scRNA-seq). These methods exploit partitioning to 1) isolate single cells or proteins, 2) detect their activity via enzymatic amplification, and 3) tag them individually by coencapsulating them with molecular barcodes. When scaled, digital assays reveal stochastic differences between proteins or cells within a population, a key to understanding biological heterogeneity. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows.
Detection of Penicillinase in Milk by Sandwich ELISA Based Polyclonal and Monoclonal Antibody.
Zhao, Yinli; Li, Guoxi
2016-01-01
A sandwich ELISA has been developed using polyclonal and monoclonal antibody for the determination of penicillinase in milk. For this purpose, specific polyclonal and monoclonal antibodies against penicillinase were generated and characterized. Using penicillinase standards prepared from 1-128 ng/mL, the method indicated that the detection limit of the sandwich ELISA, as measured in an ELISA plate reader, was as low as 0.86 ng/mL of penicillinase. For determine the accuracy, raw milk containing 2, 8, 32, and 64 ng/mL of penicillinase were tested by sandwich ELISA. Recoveries were from 93-97.5%, and the coefficient of variation [CV (%)] were from 5.55-8.38%. For interassay reproducibility, recoveries were from 89.5-95.1%, the coefficient of variation [CV (%)] were from 5.26-9.58%. This sandwich ELISA provides a useful screening method for quantitative detection of penicillinase in milk.
Schwarz, Norbert Georg; Mertens, Eva; Winter, Doris; Maiga-Ascofaré, Oumou; Dekker, Denise; Jansen, Stephanie; Tappe, Dennis; Randriamampionona, Njary; May, Jürgen; Rakotozandrindrainy, Raphael; Schmidt-Chanasit, Jonas
2017-01-01
It was previously reported that a malaria infection may interfere with the specificity of a commercial ELISA test against Zika virus (ZIKV). We analyzed 1,216 plasma samples from healthy, pregnant women collected in two sites in Madagascar in 2010 for ZIKV antibodies using a commercial ELISA and for Plasmodium infection by PCR. This screen revealed six putative ZIKV-positive samples by ELISA. These results could not be confirmed by indirect immunofluorescence assays or virus neutralization tests. Four of these six samples were also positive for P. falciparum. We noted that the frequency of malaria positivity was higher in ZIKV-ELISA positive samples (50% and 100% in the two study sites) than ZIKV-negative samples (17% and 10%, respectively), suggesting that malaria may have led to false ZIKV-ELISA positives.
Pollard, S J T; Farmer, J G; Knight, D M; Young, P J
2002-01-01
Commercial mono- and polyclonal enzyme-linked immunosorbent assay (ELISA) systems were applied to the on-site analysis of weathered hydrocarbon-contaminated soils at a former integrated steelworks. Comparisons were made between concentrations of solvent extractable matter (SEM) determined gravimetrically by Soxhlet (dichloromethane) extraction and those estimated immunologically by ELISA determination over a concentration range of 2000-330,000 mg SEM/kg soil dry weight. Both ELISA systems tinder-reported for the more weathered soil samples. Results suggest this is due to matrix effects in the sample rather than any inherent bias in the ELISA systems and it is concluded that, for weathered hydrocarbons typical of steelworks and coke production sites, the use of ELISA requires careful consideration as a field technique. Consideration of the target analyte relative to the composition of the hydrocarbon waste encountered appears critical.
Optimization and Validation of ELISA for Pre-Clinical Trials of Influenza Vaccine.
Mitic, K; Muhandes, L; Minic, R; Petrusic, V; Zivkovic, I
2016-01-01
Testing of every new vaccine involves investigation of its immunogenicity, which is based on monitoring its ability to induce specific antibodies in animals. The fastest and most sensitive method used for this purpose is enzyme-linked immunosorbent assay (ELISA). However, commercial ELISA kits with whole influenza virus antigens are not available on the market, and it is therefore essential to establish an adequate assay for testing influenza virusspecific antibodies. We developed ELISA with whole influenza virus strains for the season 2011/2012 as antigens and validated it by checking its specificity, accuracy, linearity, range, precision, and sensitivity. The results show that we developed high-quality ELISA that can be used to test immunogenicity of newly produced seasonal or pandemic vaccines in mice. The pre-existence of validated ELISA enables shortening the time from the process of vaccine production to its use in patients, which is particularly important in the case of a pandemic.
Schunn, Anne-Marie; Conraths, Franz J.; Staubach, Christoph; Fröhlich, Andreas; Forbes, Andrew; Strube, Christina
2013-01-01
In November 2008, a total of 19,910 bulk tank milk (BTM) samples were obtained from dairy farms from all over Germany, corresponding to about 20% of all German dairy herds, and analysed for antibodies against the bovine lungworm Dictyocaulus viviparus by use of the recombinant MSP-ELISA. A total number of 3,397 (17.1%; n = 19,910) BTM samples tested seropositive. The prevalences in individual German federal states varied between 0.0% and 31.2% positive herds. A geospatial map was drawn to show the distribution of seropositive and seronegative herds per postal code area. ELISA results were further analysed for associations with land-use and climate data. Bivariate statistical analysis was used to identify potential spatial risk factors for dictyocaulosis. Statistically significant positive associations were found between lungworm seropositive herds and the proportion of water bodies and grassed area per postal code area. Variables that showed a statistically significant association with a positive BTM test were included in a logistic regression model, which was further refined by controlled stepwise selection of variables. The low Pseudo R2 values (0.08 for the full model and 0.06 for the final model) and further evaluation of the model by ROC analysis indicate that additional, unrecorded factors (e.g. management factors) or random effects may substantially contribute to lungworm infections in dairy cows. Veterinarians should include lungworms in the differential diagnosis of respiratory disease in dairy cattle, particularly those at pasture. Monitoring of herds through BTM screening for antibodies can help farmers and veterinarians plan and implement appropriate control measures. PMID:24040243
Hu, Zu-Quan; Liu, Jin-Long; Li, He-Ping; Xing, Shu; Xue, Sheng; Zhang, Jing-Bo; Wang, Jian-Hua; Nölke, Greta; Liao, Yu-Cai
2012-01-01
Fusarium verticillioides is the primary causal agent of Fusarium ear and kernel rot in maize, producing fumonisin mycotoxins that are toxic to humans and domestic animals. Rapid detection and monitoring of fumonisin-producing fungi are pivotally important for the prevention of mycotoxins from entering into food/feed products. Chicken-derived single-chain variable fragments (scFvs) against cell wall-bound proteins from F. verticillioides were isolated from an immunocompetent phage display library. Comparative phage enzyme-linked immunosorbant assays (ELISAs) and sequencing analyses identified four different scFv antibodies with high sensitivity. Soluble antibody ELISAs identified two highly sensitive scFv antibodies, FvCA3 and FvCA4, with the latter being slightly more sensitive. Three-dimensional modeling revealed that the FvCA4 may hold a better overall structure with CDRH3, CDRL1 and CDRL3 centered in the core region of antibody surface compared with that of other scFvs. Immunofluorescence labeling revealed that the binding of FvCA4 antibody was localized to the cell walls of conidiospores and hyphae of F. verticillioides, confirming the specificity of this antibody for a surface target. This scFv antibody was able to detect the fungal mycelium as low as 10−2 μg/mL and contaminating mycelium at a quantity of 10−2 mg/g maize. This is the first report that scFv antibodies derived from phage display have a wide application for rapid and accurate detection and monitoring of fumonisin-producing pathogens in agricultural samples. PMID:22837678
Pinto Torres, Joar E; Goossens, Julie; Ding, Jianzu; Li, Zeng; Lu, Shaohong; Vertommen, Didier; Naniima, Peter; Chen, Rui; Muyldermans, Serge; Sterckx, Yann G-J; Magez, Stefan
2018-06-13
Animal African trypanosomosis (AAT), a disease affecting livestock, is caused by parasites of the Trypanosoma genus (mainly T. vivax and T. congolense). AAT is widespread in Sub-Saharan Africa, where it continues to impose a heavy socio-economic burden as it renders development of sustainable livestock rearing very strenuous. Active case-finding and the identification of infected animals prior to initiation of drug treatment requires the availability of sensitive and specific diagnostic tests. In this paper, we describe the development of two heterologous sandwich assay formats (ELISA and LFA) for T. congolense detection through the use of Nanobodies (Nbs). The immunisation of an alpaca with a secretome mix from two T. congolense strains resulted in the identification of a Nb pair (Nb44/Nb42) that specifically targets the glycolytic enzyme pyruvate kinase. We demonstrate that the Nb44/Nb42 ELISA and LFA can be employed to detect parasitaemia in plasma samples from experimentally infected mice and cattle and, additionally, that they can serve as 'test-of-cure' tools. Altogether, the findings in this paper present the development and evaluation of the first Nb-based antigen detection LFA to identify active T. congolense infections.
Plasma Shh levels reduced in pancreatic cancer patients
El-Zaatari, Mohamad; Daignault, Stephanie; Tessier, Art; Kelsey, Gail; Travnikar, Lisa A.; Cantu, Esperanza F.; Lee, Jamie; Plonka, Caitlyn M.; Simeone, Diane M.; Anderson, Michelle A.; Merchant, Juanita L.
2012-01-01
Objectives Normally, sonic hedgehog (Shh) is expressed in the pancreas during fetal development and transiently after tissue injury. Although pancreatic cancers express Shh, it is not known if the protein is secreted into the blood and whether its plasma levels change with pancreatic transformation. The goal of this study was to develop an ELISA to detect human Shh in blood, and determine the levels in subjects with and without pancreatic cancer. Methods A human Shh ELISA assay was developed, and plasma Shh levels were measured in blood samples from normal volunteers and subjects with pancreatitis or pancreatic cancer. The biological activity of plasma Shh was tested using NIH-3T3 cells. Results The average levels of Shh in human blood were lower in pancreatitis and pancreatic cancer patients than in normal individuals. Hematopoietic cells did not express Shh suggesting that Shh is secreted into the bloodstream. Plasma fractions enriched for Shh did not induce Gli-1 mRNA suggesting that the protein was not biologically active. Conclusions Shh is secreted from tissues and organs into the circulation but its activity is blocked by plasma proteins. Reduced plasma levels were found in pancreatic cancer patients, but alone were not sufficient to predict pancreatic cancer. PMID:22513293
Sprague, Lisa D; Mengele, Karin; Schilling, Daniela; Geurts-Moespot, Anneke; Sweep, Fred C G J; Stadler, Peter; Schmitt, Manfred; Molls, Michael
2006-01-01
In squamous cell carcinoma of the head and neck (SCCHN), hypoxia is considered a crucial physiological modulator for malignant progression, wherebythe plasminogen activation system is involved in overlapping functions such as moulding of the extracellular matrix, cell proliferation and signal transduction. Little is known about the effects of reoxygenation on the plasminogen activation system in SCCHN cells. Three human SCCHN cell lines (BHY, CAL27, FaDu) and a non-transformed human fibroblast cell line (VH7) were exposed to hypoxic (<0.5% O(2)) conditions for up to 72 h and subsequently reoxygenated at normoxic conditions for 24 h. Urokinase-type plasminogen activator (uPA) and plasminogen activator inhibitor-1 (PAI-1) protein concentration and former protein activity were determined by ELISA and complex ELISA, respectively. Reoxygenation induced significant changes in cell-associated and secreted PAI-1 protein compared to the normoxic control. Significant increase in cell-associated and secreted uPA protein after reoxygenation was only observed for some of the cell lines. Determination of uPA-PAI-1 complex formation revealed the release of active protein into the cell supernatant. The beneficial role of reoxygenation during radiation therapy is widely accepted. However, reoxygenation does not seem to counteract the effects induced by hypoxia on the plasminogen activation system. Fatally irradiated reoxygenat- ed tumour cells might still produce sufficient amounts of 'harmful' protein and thus initiate a path for invasion and metastasis for surviving tumour cells.
Students as Technicians: Screening Newborns for Cystic Fibrosis
ERIC Educational Resources Information Center
Gusky, Sharon
2014-01-01
In this activity, freshman college students learn biotechnology techniques while playing the role of a laboratory technician. They perform simulations of three diagnostic tests used to screen newborns for cystic fibrosis. By performing an ELISA, a PCR analysis, and a conductivity test, students learn how biotechnology techniques can be used to…
Rossi, Daniela; Volanti, Paolo; Brambilla, Liliana; Colletti, Tiziana; Spataro, Rossella; La Bella, Vincenzo
2018-03-01
Elevated cerebrospinal fluid (CSF), Neurofilament Light (NF-L) and phosphorylated Heavy (pNF-H) chain levels have been found in Amyotrophic Lateral Sclerosis (ALS), with studies reporting a correlation of both neurofilaments (NFs) with the disease progression. Here, we measured NF-L and pNF-H concentrations in the CSF of ALS patients from a single tertiary Center and investigated their relationship with disease-related variables. A total of 190 ALS patients (Bulbar, 29.9%; Spinal, 70.1%; M/F = 1.53) and 130 controls with mixed neurological diseases were recruited. Demographic and clinical variables were recorded, and ΔFS was used to rate the disease progression. Controls were divided into two cohorts: (1) patients with non-inflammatory neurological diseases (CTL-1); (2) patients with acute/subacute inflammatory diseases and tumors, expected to lead to significant axonal and tissue damage (CTL-2). For each patient and control, CSF was taken at the time of the diagnostic work-up and stored following the published guidelines. CSF NF-L and pNF-H were assayed with commercially available ELISA-based methods. Standard curves (from independent ELISA kits) were highly reproducible for both NFs, with a coefficient of variation < 20%. We found that CSF NF-L and pNF-H levels in ALS were significantly increased when compared to CTL-1 (NF-L: ALS, 4.7 ng/ml vs CTL-1, 0.61 ng/ml, p < 0.001; pNF-H: ALS, 1.7 ng/ml vs CTL-1, 0.03 ng/ml, p < 0.0001), but not to CTL-2. Analysis of different clinical and prognostic variables disclosed meaningful correlations with both NF-L and pNF-H levels. Our results, from a relatively large ALS cohort, confirm that CSF NF-L and pNF-H represent valuable diagnostic and prognostic biomarkers in ALS.
Piekkala, Maija; Alfthan, Henrik; Merras-Salmio, Laura; Puustinen Wikström, Anne; Heiskanen, Kaarina; Jaakkola, Tytti; Klemetti, Paula; Md, Martti Färkkilä; Kolho, Kaija-Leena
2018-06-01
Measuring fecal calprotectin (FC) in a laboratory is time-consuming and that is why home tests have been developed. We studied the use of an FC home test in pediatric patients with inflammatory bowel disease (PIBD) in real-life settings. The patients were asked to perform the IBDoc FC home test monthly for 6 months and to report their clinical disease activity at testing. Clinical decision-making, however, was guided by routine FC enzyme-linked immunosorbent assay (ELISA) for patients with raised IBDoc values. Spare frozen samples were analyzed using ELISA and IBDoc in the laboratory. The participants completed a questionnaire about FC testing at the start and end of the study. Of the 52 patients, 35 (67%) ages 5 to 18 years completed the study, and 197 home tests were performed. Of these, 15% failed, mainly because of technical reasons. Just under half of the patients (47%) considered home testing comparable or superior to routine testing. In contrast, the parents were unsatisfied (61%), mostly because the IBDoc results were significantly different from ELISA and they found the phone application difficult to handle but whenever the IBDoc was performed by a laboratory professional it was comparable with ELISA, suggesting that practical issues hampered home testing. Despite their reservations, more than 80% of parents felt that home testing would improve disease management. PIBD patients and their families were interested in FC home monitoring and willing to adopt testing as a part of their disease management, but this approach requires thorough guidance.
Kawano, Hiroyuki; Yamamoto, Haruko; Miyata, Shigeki; Izumi, Manabu; Hirano, Teruyuki; Toratani, Naomi; Kakutani, Isami; Sheppard, Jo-Ann I; Warkentin, Theodore E; Kada, Akiko; Sato, Shoichiro; Okamoto, Sadahisa; Nagatsuka, Kazuyuki; Naritomi, Hiroaki; Toyoda, Kazunori; Uchino, Makoto; Minematsu, Kazuo
2011-01-01
Acute ischaemic stroke patients sometimes receive heparin for treatment and/or prophylaxis of thromboembolic complications. This study was designed to elucidate the incidence and clinical features of heparin-induced thrombocytopenia (HIT) in acute stroke patients treated with heparin. We conducted a prospective multicentre cohort study of 267 patients who were admitted to three stroke centres within 7 d after stroke onset. We examined clinical data until discharge and collected blood samples on days 1 and 14 of hospitalization to test anti-platelet factor 4/heparin antibodies (anti-PF4/H Abs) using an enzyme-linked immunosorbent assay (ELISA); platelet-activating antibodies were identified by serotonin-release assay (SRA). Patients with a 4Ts score ≥4 points, positive-ELISA, and positive-SRA were diagnosed as definite HIT. Heparin was administered to 172 patients (64·4%: heparin group). Anti-PF4/H Abs were detected by ELISA in 22 cases (12·8%) in the heparin group. Seven patients had 4Ts ≥ 4 points. Among them, three patients (1·7% overall) were also positive by both ELISA and SRA. National Institutes of Health Stroke Scale score on admission was high (range, 16–23) and in-hospital mortality was very high (66·7%) in definite HIT patients. In this study, the incidence of definite HIT in acute ischaemic stroke patients treated with heparin was 1·7% (95% confidence interval: 0·4–5·0). The clinical severity and outcome of definite HIT were unfavourable. PMID:21671895
Oral rapid test: an alternative to traditional HIV screening in Chile
Irarrazábal, Lisette Paola; Ferrer, Lilian; Cianelli, Rosina; Lara, Loreto; Reed, Reiley; Levy, Judith; Pérez, Carlos
2016-01-01
Objective To compare the sensitivity and specificity of an Oral Rapid Test (ORT) to that of the Enzyme-Linked Immunosorbent Assay (ELISA) for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants’ perceptions of the ORT compared to the ELISA. Methods A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. Results The ELISA reported 184 (37%) of the 497 participants as being “positive” for HIV antibodies; the ORT showed 181 (36.4%) as being “reactive” for HIV. The ORT showed a sensitivity of 98.4% (95.7%–99.9%, 95% Confidence Interval) and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001). Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. Conclusions The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. PMID:23939368
Butler, J E; McGivern, P L; Swanson, P
1978-01-01
A modification of the standard enzyme-linked immunosorbent assay (ELISA) is described which circumvents the requirement for specifically purified antibodies from which antibody-enzyme complexes are made. The assay utilizes the principle of a soluble anti-alkaline phosphatase immune complex (AP-A-AP) and has been called the amplified ELISA. Methods for preparing and evidence for the specificity of rabbit anti-rat gamma-FC, IgM (mu) and IgA (alpha) are presented. These reagents are used to measure anti-DNP antibodies belonging to classes IgG, IgM and IgA in rat serum. Using antiglobulin and anti-enzyme reagents prepared in guinea pigs, anti-ovalbumin antibodies are measured in rabbit serum. Titration curves are similar when the amplified ELISA is compared to the standard ELISA. A change in slope suggesting an effect of saturation of antigen sites, occurs at the same input antibody concentration for both assays. Determination of the anti-DNP concentration of unknown sera by extrapopulation from titration graphs of a known serum suggests that the value is overestimated, i.e., amplified when the amplified ELISA is used. In addition, the amplified ELISA has an improved ability to detect low levels of antibody. Evidence is presented which illustrates how the use of optimally conjugated DNP-proteins, age of conjugates, and optimal dilutions of secondary antiglobulins and the AP-A-AP reduce non-specific binding in the amplified ELISA. The amplified ELISA is capable of detecting 2.4 ng of antibody to ovalbumin in a one: one million dilution of rabbit serum with high reproducibility and low background.
Dhaliwal, G S; Murray, R D; Dobson, H; Montgomery, J; Ellis, W A
1996-03-01
Samples of cervico-vaginal mucus from 163 bulling cows (group 1) and post calving discharges from 59 newly calved cows (group 2) in five dairy herds naturally infected with Leptospira interrogans serovar hardjo were examined for the presence of antigen and IgG and IgA antibodies by using two ELISA systems which were protein or carbohydrate based. Corresponding serum samples were examined for systemic immune responses by using a microscopic agglutination test (MAT) and IgG-ELISA tests. Antigen was detected by direct immunofluorescence in six of the 163 samples of cervico-vaginal mucus. Both IgG and IgA antibodies were detected by ELISA in the genital discharges with a prevalence much higher than that obtained by the MAT but lower than that observed with the serum IgG-ELISA. Combining both groups, none of the MAT-positive cattle was negative by serum-ELISA. By using the protein or carbohydrate fraction serum IgG-ELISA assays, respectively, 29 or 41 per cent of the MAT-negative cows were positive at a titre of at least 1:40. Similarly, eight or 23 samples (10 or 27 per cent) had titres of at least 1:20 in the genital discharge ELISA for IgG and IgA antibodies, respectively. The serum IgG-ELISA was the most efficient in detecting hardjo antibodies, but in group 2 the IgG- and IgA-ELISA of the post calving discharge proved to be equally effective.
Posttransplant sCD30 as a biomarker to predict kidney graft outcome.
Süsal, Caner; Opelz, Gerhard
2012-09-08
In current clinical praxis, monitoring of immunosuppressive agents in organ transplantation is restricted to measurement of drug blood levels and does not consider the drug's variable effect on the individual patient's immune system. Establishment of biological markers that measure the biological effect of immunosuppressive drugs is desirable and would enable the identification of patients who are at risk of developing rejection, or patients who are suitable for minimization or weaning of immunosuppressive therapy. Several studies demonstrated that the technically simple posttransplant measurement in serum of the T cell activation marker soluble CD30 (sCD30) allows prediction of subsequent graft loss in kidney transplant recipients. sCD30 is a relatively large molecule and therefore an attractive biological marker which is resistant to repeated thawing cycles and temperature differences and easily determined using commercial ELISA. Whether sCD30-based prospective adjustment of immunosuppressive therapy can prevent irreversible graft damage and improve long-term graft outcome awaits evaluation in randomized controlled trials. Copyright © 2011 Elsevier B.V. All rights reserved.
Anti-enrofloxacin antibody production by using enrofloxacin-screened HSA as an immunogen
NASA Astrophysics Data System (ADS)
Liu, Chune; Lin, Hong; Cao, Limin; Jiang, Jie
2005-07-01
A two-step zero-length cross-linking procedure using active esters was successfully adopted for conjugating enrofloxacin (EF) to human serum albumin (HSA). The derived conjugate was characterized by UV spectrum and then used for immunization of BALB/C mice. In enzyme-linked immunosorbent assay (ELISA) and competitive inhibition ELISA experiments, the derived antiserum exhibited high antibody titer (greater than 1:250 000) as well as varied cross-reactivity (from 97.8% to 161.7%) to three analogs of EF belonging to fluoroquinolones family. But over the concentration range studied, no significant cross-reactivity was observed to other group of antibiotics (chloramphenicol, oxytetracycline, sulphamethoxazole and nysfungin). It was confirmed that the synthesized immunogen was highly antigenic and elicited specific antibody responses in BALB/C mice against EF.
Expression of Molecular Markers in Brain, Serum, and Lung Tissues Following Hypobaric Hypoxia
2018-01-01
8 4.2 HIF-1α ELISA Results...9 4.3 Prolyl-4-hydroxylase Alpha Polypeptide I (P4Ha1) ELISA Results...10 4.4 Vascular Endothelial Growth Factor ELISA Results .......................................................12
Blich, Miry; Golan, Amnon; Arvatz, Gil; Sebbag, Anat; Shafat, Itay; Sabo, Edmond; Cohen-Kaplan, Victoria; Petcherski, Sirouch; Avniel-Polak, Shani; Eitan, Amnon; Hammerman, Haim; Aronson, Doron; Axelman, Elena; Ilan, Neta; Nussbaum, Gabriel; Vlodavsky, Israel
2013-02-01
Factors and mechanisms that activate macrophages in atherosclerotic plaques are incompletely understood. We examined the capacity of heparanase to activate macrophages. Highly purified heparanase was added to mouse peritoneal macrophages and macrophage-like J774 cells, and the levels of tumor necrosis factor-α, matrix metalloproteinase-9, interlukin-1, and monocyte chemotactic protein-1 were evaluated by ELISA. Gene expression was determined by RT-PCR. Cells collected from Toll-like receptor-2 and Toll-like receptor-4 knockout mice were evaluated similarly. Heparanase levels in the plasma of patients with acute myocardial infarction, stable angina, and healthy subjects were determined by ELISA. Immunohistochemistry was applied to detect the expression of heparanase in control specimens and specimens of patients with stable angina or acute myocardial infarction. Addition or overexpression of heparanase variants resulted in marked increase in tumor necrosis factor-α, matrix metalloproteinase-9, interlukin-1, and monocyte chemotactic protein-1 levels. Mouse peritoneal macrophages harvested from Toll-like receptor-2 or Toll-like receptor-4 knockout mice were not activated by heparanase. Plasma heparanase level was higher in patients with acute myocardial infarction, compared with patients with stable angina and healthy subjects. Pathologic coronary specimens obtained from vulnerable plaques showed increased heparanase staining compared with specimens of stable plaque and controls. Heparanase activates macrophages, resulting in marked induction of cytokine expression associated with plaque progression toward vulnerability.
Sumbria, Deepak; Singla, L D; Kumar, Sanjay; Sharma, Amrita; Dahiya, Rajesh K; Setia, Raj
2016-03-01
Equine piroplasmosis is a febrile, tick-borne disease of equids predominately caused by obligatory intra-erythrocytic protozoa Theileria equi in the Indian sub-continent. A cross-sectional study was carried out on 464 equids (426 horses and 38 donkeys/mules) in Punjab, India to assess the level of exposure to equine piroplasmosis by 18S rRNA gene nested polymerase chain reaction (nPCR) and equine merozoite antigen-2 (EMA2) indirect-ELISA (enzyme linked immunosorbent assay), to investigate risk factors and haemato-biochemical alterations associated with the infection. The endemicity of the disease was confirmed by positive PCR amplification in 21.77% and positive antibody titers in 49.78% equid samples. There was a fair agreement between these two diagnostic techniques (Kappa coefficient=0.326). The spatial distribution analysis revealed an increasing trend of T. equi prevalence from north-eastern to south-western region of Punjab by both the techniques correspondingly, which proffered a direct relation with temperature and inverse with humidity variables. The relatively prominent risk factor associated with sero-positivity was the presence of other domestic animals in the herd, while the propensity of finding a positive PCR amplification was higher in donkeys/mules, animal kept at unorganised farm or those used for commercial purposes as compared to their counterparts. There was a significant increase in globulins, gamma glutamyl-transferase, total bilirubin, direct bilirubin, indirect bilirubin, glucose levels and decrease in total erythrocyte count, haemoglobin, packed cell volume by animals, which were revealed positive by nPCR (may or may not positive by indirect-ELISA) and increase in creatinine, total bilirubin, direct bilirubin, glucose and decrease in total erythrocytes count by animals, which were revealed positive by indirect-ELISA (alone). To our knowledge, this study, for the first time, brings out a comprehensive report on the status on spatial distribution of T. equi in Punjab (India) state, thoroughly investigated by molecular and serological techniques, evaluating various environmental and demographic risk factors along with the haemato-biochemical alterations in the exposed animals. Copyright © 2015 Elsevier B.V. All rights reserved.
Serology of Typhoid Fever in an Area of Endemicity and Its Relevance to Diagnosis
House, Deborah; Wain, John; Ho, Vo A.; Diep, To S.; Chinh, Nguyen T.; Bay, Phan V.; Vinh, Ha; Duc, Minh; Parry, Christopher M.; Dougan, Gordon; White, Nicholas J.; Hien, Tran Tinh; Farrar, Jeremy J.
2001-01-01
Currently, the laboratory diagnosis of typhoid fever is dependent upon either the isolation of Salmonella enterica subsp. enterica serotype Typhi from a clinical sample or the detection of raised titers of agglutinating serum antibodies against the lipopolysaccharide (LPS) (O) or flagellum (H) antigens of serotype Typhi (the Widal test). In this study, the serum antibody responses to the LPS and flagellum antigens of serotype Typhi were investigated with individuals from a region of Vietnam in which typhoid is endemic, and their usefulness for the diagnosis of typhoid fever was evaluated. The antibody responses to both antigens were highly variable among individuals infected with serotype Typhi, and elevated antibody titers were also detected in a high proportion of serum samples from healthy subjects from the community. In-house enzyme-linked immunosorbent assays (ELISAs) for the detection of specific classes of anti-LPS and antiflagellum antibodies were compared with other serologically based tests for the diagnosis of typhoid fever (Widal TO and TH, anti-serotype Typhi immunoglobulin M [IgM] dipstick, and IDeaL TUBEX). At a specificity of ≥0.93, the sensitivities of the different tests were 0.75, 0.55, and 0.52 for the anti-LPS IgM, IgG, and IgA ELISAs, respectively; 0.28 for the antiflagellum IgG ELISA; 0.47 and 0.32 for the Widal TO and TH tests, respectively; and 0.77 for the anti-serotype Typhi IgM dipstick assay. The specificity of the IDeaL TUBEX was below 0.90 (sensitivity, 0.87; specificity, 0.76). The serological assays based on the detection of IgM antibodies against either serotype Typhi LPS (ELISA) or whole bacteria (dipstick) had a significantly higher sensitivity than the Widal TO test when used with a single acute-phase serum sample (P ≤ 0.007). These tests could be of use for the diagnosis of typhoid fever in patients who have clinical typhoid fever but are culture negative or in regions where bacterial culturing facilities are not available. PMID:11230418
Marangoni, Antonella; Sparacino, Monica; Cavrini, Francesca; Storni, Elisa; Mondardini, Valeria; Sambri, Vittorio; Cevenini, Roberto
2005-04-01
In this study the raising and development of the immune response to Borrelia burgdorferi infection in 45 Italian patients suffering from culture-confirmed Lyme borreliosis erythema migrans was investigated. A total of 95 serially collected serum samples were tested by using three different commercial ELISAs: recomWell Borrelia (Mikrogen), Enzygnost Borreliosis (DADE Behring) and Quick ELISA C6 Borrelia (Immunetics). The sensitivities of the ELISAs were as follows: Enzygnost Borreliosis IgM, 70.5 %; Quick ELISA C6 Borrelia, 62.1 %; recomWell Borrelia IgM, 55.7 %; recomWell Borrelia IgG, 57.9 %; and Enzygnost Borreliosis IgG, 36.8 %. In order to compare the specificity values of the three ELISAs, a panel of sera obtained from blood donors (210 samples coming from a non-endemic area and 24 samples from an endemic area) was tested, as well as sera from patients suffering from some of the most common biological conditions that could result in false-positive reactivity in Lyme disease serology (n = 40). RecomWell Borrelia IgG and recomWell Borrelia IgM were the most specific (97.1 % and 98.9 %, respectively), followed by Quick ELISA C6 Borrelia (96.7 %). Enzygnost Borreliosis IgG and IgM achieved 90.1 % and 92.3 % specificity, respectively. Sera that gave discrepant results when tested by the three ELISAs were further analysed by Western blotting.
Tawfeek, Gihan M; Elwakil, Hala S; El-Hoseiny, Laila; Thabet, Hala S; Sarhan, Rania M; Awad, Nabil S; Anwar, Wagida A
2011-02-01
The diagnosis of patients with cystic echinococcosis (CE) by means of serology has a limited support in clinical practice due to cross-reactivity with other helminthes leading to overestimation of the parasite's true prevalence. A wealth of reports on the diagnostic performance of antigen B (AgB) has been produced. This study was designed to comparatively assess the diagnostic efficacy of crude sheep hydatid cyst fluid (HCF), AgB and its subunit (12 KDa) to detect IgG or IgG4 antibodies in CE patients' sera using enzyme-linked immunosorbent assay (ELISA).The best diagnostic performance was obtained with anti-HCF IgG ELISA which gave 92.4% sensitivity and 92.6% specificity. Despite the low sensitivity of anti AgB IgG ELISA (84%), it gave the best specificity (94.4%) with less cross-reaction with sera of subjects infected with other parasites. In conclusion, it is recommended to use anti-HCF IgG ELISA for initial screening in large seroprevalence studies. Further analysis of positive serum samples with anti AgB IgG ELISA would allow the confirmation of true positives. Specific IgG4 ELISA may represent a complementary assay, useful as secondary confirmatory tests for patients with suspected CE and negative for total IgG ELISA.
Analysis of fenbendazole residues in bovine milk by ELISA.
Brandon, David L; Bates, Anne H; Binder, Ronald G; Montague, William C; Whitehand, Linda C; Barker, Steven A
2002-10-09
Fenbendazole residues in bovine milk were analyzed by ELISAs using two monoclonal antibodies. One monoclonal antibody (MAb 587) bound the major benzimidazole anthelmintic drugs, including fenbendazole, oxfendazole, and fenbendazole sulfone. The other (MAb 591) was more specific for fenbendazole, with 13% cross-reactivity with the sulfone and no significant binding to the sulfoxide metabolite. The limit of detection of the ELISA method in the milk matrix was 7 ppb for MAb 587 and 3 ppb for MAb 591. Fenbendazole was administered in feed, drench, and paste form to three groups of dairy cattle. Milk was collected immediately before dosing and then every 12 h for 5 days. The ELISA indicated that residue levels varied widely among individual cows in each group. Fenbendazole levels peaked at approximately 12-24 h and declined rapidly thereafter. Metabolites were detected at much higher levels than the parent compound, peaked at approximately 24-36 h, and declined gradually. Residue levels were undetectable by 72 h. The ELISA data correlated well with the total residues determined by chromatographic analysis, but the use of the two separate ELISAs did not afford an advantage over ELISA with the single, broadly reactive MAb 587. The ELISA method could be used to flag high-residue samples in on-site monitoring of fenbendazole in milk and is a potential tool for studying drug pharmacokinetics.
Snyder, M H; Banks, S; Murphy, B R
1988-01-01
We modified an existing enzyme-linked immunosorbent assay (ELISA) to be able to use new spectrophotometers which can measure the rate of color development in microtiter wells. This new kinetic-based ELISA (KELISA) required only a single dilution of specimen rather than the multiple dilutions required with endpoint ELISA. In addition, 10- to 100-fold-less specimen was required to perform the KELISA than the ELISA. The level of serum or nasal wash antibody against surface glycoproteins of influenza A or influenza B viruses determined by KELISA was reproducible and correlated highly with the results of endpoint ELISA or hemagglutination inhibition tests. The difference between the KELISA rates, which indicated than an antibody response to infection had occurred, was defined and was analogous to a 2.2-fold rise in titer for serum and a 3.4-fold rise in titer for nasal wash determined by endpoint ELISA. The KELISA was similar to endpoint ELISAs in its ability to detect rises in antibody level in paired serum or nasal wash specimens obtained from volunteers who received live attenuated influenza A reassortant virus vaccines. By eliminating the need for multiple dilutions, the use of KELISA offers the advantage of increasing the number of assays that can be performed by the same personnel compared with endpoint ELISA, while it maintains sensitivity and specificity. PMID:3182992
Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka
2018-04-09
To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.
Mosadeghi, Parvin; Heydari-Zarnagh, Hafez
2018-04-01
We aimed to develope a peptide-based indirect ELISA to detect antibodies against Human T-lymphotropic virus type I (HTLV-I). Two chimeric peptides (CP-1 and CP-2) were designed using linear immunodominant epitopes of gp-46-I, and gp21-I proteins, according to the sequence from Uniprot database. These peptides were studied initially in the ELISA using infected sera. The most promising peptideCP-1, was used to develop a peptide ELISA for detection of HTLV-I infected sera. The optimal conditions for CP-1ELISA were: the optimum coating buffer was 100mM NaHCO3, pH 9.6; coating peptide concentration was 10 µg/mL; the optimal blocking buffer was5% fetal bovine serum (FBS); the secondary antibody concentration was 1:2000; and serum dilution was 1:20. 20serum samples from HTLV-I infected patients were evaluated by ELISA developed. CP-1 showed high antigenicity while lacking any cross-reactivity with normal human sera. The results of evaluations indicated that in comparison with commercial ELISA, CP-1 ELISA showed good sensitivity and specificity. With further validation, CP-1as described in the present study could be introduced as novel reliable and cost-effective candidates for the high-specific screening of HTLV-I/-II infections in endemic regions.
Thiha, Aung; Ibrahim, Fatimah
2015-05-18
The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.
Zhuo, Xunhui; Sun, Hongchao; Zhang, Zhi; Luo, Jiaqing; Shan, Ying; Du, Aifang
2017-06-01
Serologic tests are widely accepted and applied as means to detect anti- Toxoplasma gondii immunoglobulin G antibodies. In this study, recombinant matrix antigen (rMAG1) was induced by isopropyl-β-d-thiogalactoside and purified by nickel-nitrilotriacetic acid purification system. We then developed and optimized an indirect enzyme-linked immunosorbent assay (ELISA) through checkerboard assays using serial dilutions of antigens and sera to assess the potential use of rMAG1 in serologic detection of T. gondii infection in dogs. Serum samples from 93 domestic dogs were analyzed by western blot and rMAG1-ELISA. The results were compared with those obtained from an ELISA with the soluble Toxoplasma lysate antigens (TLA). We found that although yielding an excellent agreement (96.7%) with western blot data (κ = 0.9659), rMAG1-ELISA produced higher sensitivity (93.9% vs. 87.8%) and specificity (98.3% vs. 96.7%) than TLA-ELISA. In addition, receiver operating characteristic analysis also revealed that rMAG1-ELISA is in more agreement with western blot (area under the curve [AUC] = 0.985) relative to TLA-ELISA (AUC = 0.955). These results indicated that the rMAG1-ELISA established in this study provides a promising and reliable tool for serologic detection of T. gondii infection in dogs.
Petho, Zoltan; Balajthy, Andras; Bartok, Adam; Bene, Krisztian; Somodi, Sandor; Szilagyi, Orsolya; Rajnavolgyi, Eva; Panyi, Gyorgy; Varga, Zoltan
2016-03-01
Ion channels are crucially important for the activation and proliferation of T lymphocytes, and thus, for the function of the immune system. Previous studies on the effects of channel blockers on T cell proliferation reported variable effectiveness due to differing experimental systems. Therefore our aim was to investigate how the strength of the mitogenic stimulation influences the efficiency of cation channel blockers in inhibiting activation, cytokine secretion and proliferation of T cells under standardized conditions. Human peripheral blood lymphocytes were activated via monoclonal antibodies targeting the TCR-CD3 complex and the co-stimulator CD28. We applied the blockers of Kv1.3 (Anuroctoxin), KCa3.1 (TRAM-34) and CRAC (2-Apb) channels of T cells either alone or in combination with rapamycin, the inhibitor of the mammalian target of rapamycin (mTOR). Five days after the stimulation ELISA and flow cytometric measurements were performed to determine IL-10 and IFN-γ secretion, cellular viability and proliferation. Our results showed that ion channel blockers and rapamycin inhibit IL-10 and IFN-γ secretion and cell division in a dose-dependent manner. Simultaneous application of the blockers for each channel along with rapamycin was the most effective, indicating synergy among the various activation pathways. Upon increasing the extent of mitogenic stimulation the anti-proliferative effect of the ion channel blockers diminished. This phenomenon may be important in understanding the fine-tuning of T cell activation. Copyright © 2016 European Federation of Immunological Societies. Published by Elsevier B.V. All rights reserved.
Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L
2017-11-01
Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain milk ELISA kits are capable of detecting residues in all varieties of cheese. However, commercial milk ELISA kits are capable of semiquantitative detection of cheese residues in foods, or in industry settings for the validation of allergen cleaning programs. © 2017 Institute of Food Technologists®.
Sun, S; Karsdal, M A; Bay-Jensen, A C; Sørensen, M G; Zheng, Q; Dziegiel, M H; Maksymowych, W P; Henriksen, K
2013-10-01
Cathepsin K plays essential roles in bone resorption and is intensely investigated as a therapeutic target for the treatment of osteoporosis. Hence an assessment of the active form of cathepsin K may provide important biological information in metabolic bone diseases, such as osteoporosis or ankylosing spondylitis. Presently there are no robust assays for the assessment of active cathepsin K in serum, and therefore an ELISA specifically detecting the N-terminal of the active form of cathepsin K was developed. The assay was technically robust, with a lowest limit of detection (LOD) of 0.085 ng/mL. The average intra- and inter-assay CV% were 6.60% and 8.56% respectively. The dilution recovery and spike recovery tests in human serum were within 100±20% within the range of the assay. A comparison of latent and active cathepsin K confirmed specificity towards the active form. Quantification of the levels of active cathepsin K in supernatants of purified human osteoclasts compared to corresponding macrophages showed a 30-fold induction (p<0.001). In contrast, in serum samples from osteoporotic women on estrogen or bisphosphonate therapy and from ankylosing spondylitis patients no clinically relevant differences were observed. In summary, we have developed a robust and sensitive assay specifically detecting the active form of cathepsin K; however, while it monitors osteoclasts with high specificity in vitro, it appears that circulating levels of active cathepsin K do not reflect bone changes under these circumstances. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Moser, M; Menz, G; Blaser, K; Crameri, R
1994-01-01
A 32-kDa nonglycosylated alkaline protease (EC 3.4.1.14) with elastolytic activity, secreted by the opportunistic pathogen Aspergillus fumigatus ATCC 42202, is suggested to be a virulence factor of this fungus. The enzyme is a serine protease of the subtilisin family, and its cDNA nucleotide sequence has recently been reported. We have cloned the cDNA encoding the mature protease into a high-level Escherichia coli expression plasmid and produced the recombinant protease as a fusion protein with a six-adjacent-histidine affinity tag at the carboxy terminus. Subsequently, the recombinant protease was purified to homogeneity, with affinity chromatography yielding 30 to 40 mg of recombinant protease per liter of E. coli culture. Refolded recombinant protease, in comparison with native protease, demonstrated weak enzymatic activity but similar immunochemical characteristics as analyzed by antigen-specific enzyme-linked immunosorbent assay (ELISA), competition ELISA, and immunoblotting assays. To assess the allergenic potential of the protease, sera from patients with allergic bronchopulmonary aspergillosis and sera from healthy control individuals were analyzed by ELISA and immunoblotting techniques. Sera from patients with allergic bronchopulmonary aspergillosis did not have protease-specific immunoglobulin E (IgE) antibodies and, remarkably, did not show significantly elevated protease-specific IgG antibody levels compared with those in sera from healthy control individuals. This suggests that the alkaline protease from A. fumigatus does not elicit IgE antibodies and has weak immunogenicity, a property which may explain fungus persistence in allergic individuals. Images PMID:8112866
Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J
2014-04-01
We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.
Khamehchian, S; Madani, R; Rasaee, M J; Golchinfar, F; Kargar, R
2007-06-01
A competitive enzyme-linked immunosorbent assay (C-ELISA) has been developed and standardized for the detection of antibodies to the rinderpest virus (RPV) in sera from cattle, sheep, and goats. The test is specific for rinderpest because it does not detect antibodies to peste-des-petits-ruminants virus (PPRV). The test depends on the ability of the monoclonal antibody (MAb) directed against the hemagglutinin (H) protein of RPV to compete with the binding of RPV antibodies in the positive serum to the H protein of this virus. This MAb recognized a region from amino acids 575 to 583 on the H protein of RPV that is unique to the RPV H protein and is not present on the hemagglutinin-neuraminidase protein of PPRV. Another C-ELISA (peptide C-ELISA) was set up using this specific region as an antigen. A threshold value of 64.4% inhibition was established for the RPV C-ELISA, with 90 known RPV-negative and 30 RPV-positive serum samples. Using common serum samples, a cutoff value of 43.0% inhibition for the peptide C-ELISA was established. Based on statistical analysis, the overall sensitivity and specificity of the RPV C-ELISA, relative to those of a commercial kit, were found to be 90.00% and 103.33%, respectively. However, the sensitivity and specificity of the peptide C-ELISA were found to be 180.00% and 73.33%, respectively. Although a common MAb in 2 new C-ELISA systems was used, variation in their percent inhibition, due to the use of different antigens, was observed. Taking into consideration the difference in percent inhibition of the 2 described assays and the commercial kit (50%), it was found that the RPV C-ELISA and the peptide C-ELISA are more specific and sensitive tools than the commercial kit for assessing herd immune status and for epidemiologic surveillance.
Serodiagnosis of toxocariasis by ELISA using crude antigen of Toxocara canis larvae.
Jin, Yan; Shen, Chenghua; Huh, Sun; Sohn, Woon-Mok; Choi, Min-Ho; Hong, Sung-Tae
2013-08-01
Toxocariasis is a worldwide zoonosis caused by larvae of ascarid nematodes of dogs or cats, Toxocara canis or T. cati. Diagnosis of human toxocariasis currently relies on serology that uses T. canis excretory-secretory antigen to detect specific IgG antibodies by ELISA. We investigated the serodiagnostic efficacy of ELISA using crude antigen of T. canis larvae (TCLA). Serum specimens of 64 clinically confirmed toxocariasis, 115 healthy controls, and 119 other tissue-invading helminthiases were screened by ELISA using TCLA. The ELISA using TCLA showed 92.2% (59/64 patient samples) sensitivity and 86.6% (103/119) specificity. Its positive diagnostic predictivity was 78.7% and negative predictivity was 97.8%. No serum of healthy controls reacted but that of anisakiasis (45.5%), gnathostomiasis (19.2%), clonorchiasis (15.8%), sparganosis (11.1%), and cysticercosis (6.3%) cross-reacted. Immunoblot analysis on TCLA recognized antigenic proteins of 28- and 30-kDa bands in their dominant protein quantity and strong blotting reactivity. The present results indicate that the ELISA using our TCLA antigen is acceptable by the sensitivity and specificity for serodiagnosis of human toxocariasis. ELISA with TCLA is recommended to make differential diagnosis for patients with any sign of organ infiltration and eosinophilia.
Shirotani, Keiro; Futakawa, Satoshi; Nara, Kiyomitsu; Hoshi, Kyoka; Saito, Toshie; Tohyama, Yuriko; Kitazume, Shinobu; Yuasa, Tatsuhiko; Miyajima, Masakazu; Arai, Hajime; Kuno, Atsushi; Narimatsu, Hisashi; Hashimoto, Yasuhiro
2011-01-01
We have established high-throughput lectin-antibody ELISAs to measure different glycans on transferrin (Tf) in cerebrospinal fluid (CSF) using lectins and an anti-transferrin antibody (TfAb). Lectin blot and precipitation analysis of CSF revealed that PVL (Psathyrella velutina lectin) bound an unique N-acetylglucosamine-terminated N-glycans on “CSF-type” Tf whereas SSA (Sambucus sieboldiana agglutinin) bound α2,6-N-acetylneuraminic acid-terminated N-glycans on “serum-type” Tf. PVL-TfAb ELISA of 0.5 μL CSF samples detected “CSF-type” Tf but not “serum-type” Tf whereas SSA-TfAb ELISA detected “serum-type” Tf but not “CSF-type” Tf, demonstrating the specificity of the lectin-TfAb ELISAs. In idiopathic normal pressure hydrocephalus (iNPH), a senile dementia associated with ventriculomegaly, amounts of the SSA-reactive Tf were significantly higher than in non-iNPH patients, indicating that Tf glycan analysis by the high-throughput lectin-TfAb ELISAs could become practical diagnostic tools for iNPH. The lectin-antibody ELISAs of CSF proteins might be useful for diagnosis of the other neurological diseases. PMID:21876827
Shirotani, Keiro; Futakawa, Satoshi; Nara, Kiyomitsu; Hoshi, Kyoka; Saito, Toshie; Tohyama, Yuriko; Kitazume, Shinobu; Yuasa, Tatsuhiko; Miyajima, Masakazu; Arai, Hajime; Kuno, Atsushi; Narimatsu, Hisashi; Hashimoto, Yasuhiro
2011-01-01
We have established high-throughput lectin-antibody ELISAs to measure different glycans on transferrin (Tf) in cerebrospinal fluid (CSF) using lectins and an anti-transferrin antibody (TfAb). Lectin blot and precipitation analysis of CSF revealed that PVL (Psathyrella velutina lectin) bound an unique N-acetylglucosamine-terminated N-glycans on "CSF-type" Tf whereas SSA (Sambucus sieboldiana agglutinin) bound α2,6-N-acetylneuraminic acid-terminated N-glycans on "serum-type" Tf. PVL-TfAb ELISA of 0.5 μL CSF samples detected "CSF-type" Tf but not "serum-type" Tf whereas SSA-TfAb ELISA detected "serum-type" Tf but not "CSF-type" Tf, demonstrating the specificity of the lectin-TfAb ELISAs. In idiopathic normal pressure hydrocephalus (iNPH), a senile dementia associated with ventriculomegaly, amounts of the SSA-reactive Tf were significantly higher than in non-iNPH patients, indicating that Tf glycan analysis by the high-throughput lectin-TfAb ELISAs could become practical diagnostic tools for iNPH. The lectin-antibody ELISAs of CSF proteins might be useful for diagnosis of the other neurological diseases.
Quantitation of sperm bindable IgA and IgG in seminal fluid.
Howe, S E; Lynch, D M
1986-05-01
Seminal fluid and serum from 95 infertile males were assayed for sperm bindable immunoglobulins using an indirect ELISA with whole target sperm. The ELISA method was compared to seminal fluid and serum immobilization and agglutination assays (functional assays). In this infertile group, the ELISA assay was positive in 22% of seminal fluids (greater than 1.2 fg IgA/sperm and greater than 0.3 fg IgG/sperm). The seminal fluid antibodies were IgA and had an accompanying elevated IgG component in 78% of patients. There was a 96% correlation between negative seminal fluid functional assays and negative ELISA, and a 95% correlation between positive seminal fluid functional assays and positive ELISA. Positive serum sperm antibody tests were found in 71% of the infertile males with positive seminal fluid sperm antibodies, but 29% of the infertile males with strongly positive IgA seminal fluid sperm antibodies showed normal levels of serum sperm antibodies by either ELISA or functional assays. The ELISA method gives reproducible quantitation of sperm antibodies in seminal fluid and correlates well with accepted functional assays. Comparisons with serum sperm antibody assays suggests that seminal fluid sperm antibody analysis complements the serum analysis of sperm antibodies.
Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K
2010-06-01
A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.
Clavijo, A; Lin, M; Riva, J; Mallory, M; Lin, F; Zhou, E M
2001-02-01
The sequence encoding a truncated E2 glycoprotein of the Alfort/187 strain of classical swine fever virus (CSFV) was expressed in Escherichia coli using the pET expression system and the recombinant product purified by Ni-NTA agarose affinity chromatography. The antigenicity of this recombinant protein was demonstrated by immunoblot using anti- CSFV-specific antibodies. A monoclonal antibody was produced against the truncated E2 protein and used as competitor in an ELISA for the detection of antibodies to CSFV. Specific antibodies were demonstrated by competitive ELISA (C-ELISA) as early as 21 days post-infection (dpi) in experimentally infected pigs. Seroconversion was demonstrated by C-ELISA and neutralising peroxidase-linked assay (NPLA) in all infected animals by 4 weeks. No cross-reaction with antibodies to bovine viral diarrhoea virus (BVDV) was seen in the C-ELISA using sera from experimentally infected pigs. The C-ELISA is not intended as a substitute for the NPLA. However, it is expected it will be useful for monitoring and prevalence studies. It will also assist in testing a large number of samples in the event of an outbreak. Copyright 2001 Harcourt Publishers Ltd.
Development of a Peptide ELISA for the Diagnosis of Aleutian Mink Disease
Wang, Yang; Lu, Rongguang; Hu, Bo; Lv, Shuang; Xue, Xianghong; Li, Xintong; Ling, Mingyu; Fan, Sining; Zhang, Hailing; Yan, Xijun
2016-01-01
Aleutian disease (AD) is a common immunosuppressive disease in mink farms world-wide. Since the 1980s, counterimmunoelectrophoresis (CIEP) has been the main detection method for infection with the Aleutian Mink Disease Virus (AMDV). In this study, six peptides derived from the AMDV structural protein VP2 were designed, synthesized, and used as ELISA antigens to detect anti-AMDV antibodies in the sera of infected minks. Serum samples were collected from 764 minks in farms from five different provinces, and analyzed by both CIEP (a gold standard) and peptide ELISA. A peptide designated P1 (415 aa–433 aa) exhibited good antigenicity. A novel ELISA was developed using ovalbumin-linked peptide P1 to detect anti-AMDV antibodies in mink sera. The sensitivity and specificity of the peptide ELISA was 98.0% and 97.5%, respectively. Moreover, the ELISA also detected 342 early-stage infected samples (negative by CIEP and positive by PCR), of which 43.6% (149/342) were true positives. These results showed that the peptide ELISA had better sensitivity compared with CIEP, and therefore could be preferable over CIEP for detecting anti-AMDV antibodies in serological screening. PMID:27802320
Kondo, Mika; Tsuzuki, Kazuyuki; Hamada, Hiroshi; Yamaguchi Murakami, Yukie; Uchigashima, Mikiko; Saka, Machiko; Watanabe, Eiki; Iwasa, Seiji; Narita, Hiroshi; Miyake, Shiro
2012-02-01
A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was developed for residue analysis of azoxystrobin in garden crops, for which the maximum residue limits (MRLs) are 0.5-50 mg/kg in Japan. For hapten synthesis, an ethyl carboxyl group was introduced to the 4-position of the 2-cyanophenoxy group in azoxystrobin, and its cyano group was changed to a methyl group. An anti-azoxystrobin monoclonal antibody was prepared from mice immunized with hapten-keyhole limpet hemocyanin conjugate. The dc-ELISA using prepared antibody showed 50-250-fold higher sensitivity compared to the MRLs. The working range of the dc-ELISA was 10-200 ng/mL. The dc-ELISA showed high specificity to azoxystrobin. When methanol extracts from nine kinds of garden crops spiked with azoxystrobin ranging near the MRLs were analyzed, the determined results by the dc-ELISA agreed well with the results of their controls. In addition, azoxystrobin spiked in garden crops homogenates was satisfactorily extracted by methanol solution and easily analyzed. The recovery rate of dc-ELISA was 96-109% and correlated well with the results obtained by HPLC analysis.
Multi-Laboratory Validation of Estrone (E1) ELISA Methods
This project is a round-robin evaluation of commercially available Enzyme-Linked Immunosorbent Assay (ELISA) technology to quantitatively or qualitatively measure the hormone estrone (E1) in combined animal feeding operation (CAFO) receiving streams. ELISA is meant to be a simpl...
Raj, G Dhinakar; Ratnapraba, S; Matheswaran, K; Nachimuthu, K
2004-01-01
A single-serum dilution ELISA for egg drop syndrome (EDS) virus-specific antibodies was developed. In testing 425 chicken sera it was found to have a 93.6% sensitivity and 98.7% specificity relative to a hemagglutination inhibition (HI) test. The correlation coefficient for ELISA and HI titers was 0.793. The ELISA was efficacious in quantification of both vaccinal and infection antibodies and could routinely be used for screening large numbers of field sera.
Kanabagatte Basavarajappa, Mallikarjuna; Song, Haichen; Lamichhane, Chinta
2015-01-01
For detection of infectious laryngotracheitis virus (ILTV) antibody, glycoprotein B-, C-, and D-based enzyme-linked immunosorbent assays (B-, C-, and D-ELISAs, respectively) were developed. The B- and D-ELISAs showed enhanced detection of anti-ILTV antibodies in infected chickens compared to that of the commercial ELISA. Furthermore, the D-ELISA was efficient in detecting seroconversion with vectored vaccine, using recombinant Newcastle disease virus (rNDV) expressing glycoprotein D (gD) as the vaccine vector. PMID:25694519
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan
2017-01-01
Background: In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR. PMID:28878522
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan
2017-01-01
In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015- September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.
Zheng, Tao; Parkes, John P
2011-12-15
Rabbit haemorrhagic disease (RHD) is an acute fatal disease of domestic and wild European rabbits (Oryctolagus cuniculus) caused by RHD virus (RHDV). Accurate assessment of immunity is of great importance for the conservation and control of wild rabbits. We evaluated a competitive ELISA (cELISA) against isotype ELISAs for assessing the protective immunity against the disease by challenging 50 wild-caught rabbits with a lethal dose of RHDV. Death or survival to the challenge was used as a criterion to determine the performance characteristics of the assay for the assessment of immunity in rabbits. At 1:10 dilution, a serum exhibiting ≥ 25% inhibition (1:10(25)) was regarded as the presence of RHDV-specific antibodies. Eleven of 16 (68.8%) rabbits with antibodies at 1:10(25) (<1:40) died of RHD. When the cut-off was moved from 25% to 50% inhibition (1:10(50)) at 1:10 serum dilution, the assay sensitivity, specificity and accuracy for the protective immunity were improved from 84%, 54.2% and 69.4% to 84%, 100% and 91.8%, respectively. We also demonstrated at the epitope amino acid sequence level why the presence of the RHDV-cross reactive benign rabbit calicivirus, which interfered with isotype ELISAs, had little impact on the specificity of the cELISA for the diagnosis of RHDV infection. The presence of RHDV-specific antibody at 1:10(50) by the cELISA is a reliable indicator for the protective immunity. In contrast to isotype ELISAs, the cELISA is a valuable specific tool for monitoring the herd immunity to RHD for the conservation and management of wild rabbits in the field. Copyright © 2011 Elsevier B.V. All rights reserved.
Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays
Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.
2002-01-01
Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782
Rodríguez-Cortés, Alhelí; Ojeda, Ana; Todolí, Felicitat; Alberola, Jordi
2013-01-31
Leishmania infantum (syn. Leishmania chagasi) is the etiological agent of a widespread serious zoonotic disease that affects both humans and dogs. Prevalence and incidence of the canine infection are important parameters to determine the risk and the ways to control this reemergent zoonosis. Unfortunately, there is not a gold standard test for Leishmania infection. Our aim was to assess the operative validity of commercial tests used to detect antibodies to Leishmania in serum samples from experimental infections. Three ELISA tests (LEISCAN(®) Leishmania ELISA Test, INGEZIM(®) LEISHMANIA, and INGEZIM(®) LEISHMANIA VET), three immunochromatographic tests (INGEZIM(®) LEISHMACROM, SNAP(®) Leishmania, and WITNESS(®) Leishmania), and one IFAT were evaluated. LEISCAN(®) Leishmania ELISA test achieved the highest sensitivity and accuracy (both 0.98). Specificity was 1 for all tests except for IFAT. All tests but IFAT obtained a positive predictive value of 1, while the maximum negative predictive value was achieved by LEISCAN(®) Leishmania ELISA Test (0.93). The best positive likelihood ratio was obtained by INGEZIM(®) LEISHMANIA VET (30.26), while the best negative likelihood ratio was obtained by LEISCAN(®) Leishmania ELISA Test (0.02). The highest diagnostic odds ratio was achieved by LEISCAN(®) Leishmania ELISA Test (729.00). The largest area under the ROC curve was obtained by LEISCAN(®) Leishmania ELISA Test (0.981). Quantitative ELISA based tests performmed better than qualitative tests ("Rapid Tests"), and the test best suited to detect Leishmania in infected dogs and to provide clinically useful information was LEISCAN(®) Leishmania ELISA Test. This and other results point also to the need of revising the status of IFAT as a gold standard for the diagnosis of leishmaniasis. Copyright © 2012 Elsevier B.V. All rights reserved.
Pannwitz, Gunter; Haas, Bernd; Hoffmann, Bernd; Fischer, Sebastian
2009-01-01
In a closed pig establishment housing about 18,000 pigs, 2895 gilts were tested pre-export for SVD (swine vesicular disease) antibodies using Ceditest/PrioCHECK SVDV-AB ELISA. 130 gilts (4.5%) tested positive. In addition, 561 animals of this farm were sampled per random for SVD serology. One in 241 weaners (0.4%), eight in 150 gilts (5.3%) and 18 in 170 (10.6%) pregnant sows tested ELISA SVD-antibody positive. Of the ELISA positive samples, 23 tested positive in VNT (virus neutralization test). Of these, 20 VNT-positive animals were re-sampled two weeks later and re-tested via ELISA and VNT in different laboratories, displaying falling titres with one to two animals remaining VNT-positive. Epidemiological investigations and clinical examinations on site did not yield any evidence for SVD. 745 faecal samples taken from individual pigs and collected from pens tested negative in SVDV-RNA-PCR. 40 of these samples tested negative in virus isolation on cell culture. Pathological examinations on fallen pigs did not reveal any evidence for SVD either. After comparing our ELISA results with data recorded in the ELISA validation by Chenard et al. (1998), we propose that the published test performance is perhaps not currently applicable for the commercial test. Provided that SVD-antibody negative pigs were tested, a specificity of 99.6% in weaners, 95.5% in gilts and 89.4% in pregnant sows would appear to be more appropriate for the Ceditest/PrioCHECK SVDV-AB ELISA. Details are provided for all examined pigs regarding husbandry, breed, age, weeks pregnant and previous vaccinations. The results of other serological tests on the same sera are given. Possible clusterings of false-positive SVD-ELISA results are discussed.
Development of in-house serological methods for diagnosis and surveillance of chikungunya.
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-08-21
To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014-2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention's IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%-95.9%. Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease.
Development of in-house serological methods for diagnosis and surveillance of chikungunya
Galo, Saira Saborío; González, Karla; Téllez, Yolanda; García, Nadezna; Pérez, Leonel; Gresh, Lionel; Harris, Eva; Balmaseda, Ángel
2017-01-01
Objective To develop and evaluate serological methods for chikungunya diagnosis and research in Nicaragua. Methods Two IgM ELISA capture systems (MAC-ELISA) for diagnosis of acute chikungunya virus (CHIKV) infections, and two Inhibition ELISA Methods (IEM) to measure total antibodies against CHIKV were developed using monoclonal antibodies (mAbs) and hyperimmune serum at the National Virology Laboratory of Nicaragua in 2014–2015. The sensitivity, specificity, predictive values, and agreement of the MAC-ELISAs were obtained by comparing the results of 198 samples (116 positive; 82 negative) with the Centers for Disease Control and Prevention’s IgM ELISA (Atlanta, Georgia, United States; CDC-MAC-ELISA). For clinical evaluation of the four serological techniques, 260 paired acute and convalescent phase serum samples of suspected chikungunya cases were used. Results All four assays were standardized by determining the optimal concentrations of the different reagents. Processing times were substantially reduced compared to the CDC-MAC-ELISA. For the MAC-ELISA systems, a sensitivity of 96.6% and 97.4%, and a specificity of 98.8% and 91.5% were obtained using mAb and hyperimmune serum, respectively, compared with the CDC method. Clinical evaluation of the four serological techniques versus the CDC real-time RT-PCR assay resulted in a sensitivity of 95.7% and a specificity of 88.8%–95.9%. Conclusion Two MAC-ELISA and two IEM systems were standardized, demonstrating very good quality for chikungunya diagnosis and research demands. This will achieve more efficient epidemiological surveillance in Nicaragua, the first country in Central America to produce its own reagents for serological diagnosis of CHIKV. The methods evaluated here can be applied in other countries and will contribute to sustainable diagnostic systems to combat the disease. PMID:28902269
Balahbib, Abdelaali; Amarir, Fatima; Corstjens, Paul L A M; de Dood, Claudia J; van Dam, Govert J; Hajli, Amina; Belhaddad, Meryem; El Mansouri, Bouchra; Sadak, Abderrahim; Rhajaoui, Mohamed; Adlaoui, El Bachir
2017-04-06
After alleged stop of transmission of schistosomiasis and further down the line in post elimination settings, sensitive tools are required to monitor infection status to prevent potential re-emergence. In Rahala, where transmission cycle of Schistosoma haematobium is interrupted since 2004 but where 30% of snails are still infected by S. bovis, potential human S. bovis infection can't be excluded. As methods based on egg-counts do not provide the required sensitivity, antibody or antigen assays are envisaged as the most appropriate tools for this type of monitoring. In this pilot study, the performances of three assays were compared: two commercially available antibody tests (ELISA and haemagglutination format) indicating exposure, and an antigen test (lateral flow strip format) demonstrating active infection. All 37 recruited study participants resided in Rahala (Akka, province Tata, Morocco). Participants had been diagnosed and cured from schistosomiasis in the period between 1983 and 2003. In 2015 these asymptomatic participants provided fresh clinical samples (blood and urine) for analysis with the aforementioned diagnostics tests. No eggs were identified in the urine of the 37 participants. The haemagglutination test indicated 6 antibody positives whereas the ELISA indicated 28 antibody positives, one indecisive and one false positive. ELISA and haemagglutination results matched for 18 individuals, amongst which 5 out of 6 haemagglutination positives. With the antigen test (performed on paired serum and urine samples), serum from two participants (cured 21 and 32 years ago) indicated the presence of low levels of the highly specific Schistosoma circulating anodic antigen (CAA), demonstrating low worm level infections (less than 5 pg/ml corresponding to probably single worm pair). One tested also CAA positive with urine. ELISA indicated the presence of human anti-Schistosoma antibodies in these two CAA positive cases, haemagglutination results were negative. To prevent reemergence of schistosomiasis in Morocco current monitoring programs require specific protocols that include testing of antibody positives for active infection by the UCP-LF CAA test, the appropriate diagnostic tool to identify Schistosoma low grade infections in travelers, immigrants and assumed cured cases. The test is genus specific will also identify infections related to S. bovis.
Development and evaluation of porcine cysticercosis QuickELISA in Triturus EIA analyzer.
Handali, Sukwan; Pattabhi, Sowmya; Lee, Yeuk-Mui; Silva-Ibanez, Maria; Kovalenko, Victor A; Levin, Andrew E; Gonzalez, Armando E; Roberts, Jacquelin M; Garcia, Hector H; Gilman, Robert H; Hancock, Kathy; Tsang, Victor C W
2010-01-01
We evaluated three diagnostic antigens (recombinant GP50, recombinant T24H, and synthetic Ts18var1) for cysticercosis and found that all three performed well in detecting cysticercosis in humans and pigs in several assay formats. These antigens were adapted to a new antibody detection format (QuickELISA). With one single incubation step which involves all reactants except the enzyme substrate, the QuickELISA is particularly suited for automation. We formatted the QuickELISA for the Triturus EIA analyzer for testing large numbers of samples. We found that in QuickELISA formats rGP50 and rT24H have better sensitivity and specificity than sTs18var1 for detecting porcine cysticercosis.
Slobodin, Gleb; Ahmad, Mohammad Sheikh; Rosner, Itzhak; Peri, Regina; Rozenbaum, Michael; Kessel, Aharon; Toubi, Elias; Odeh, Majed
2010-01-01
The role and function of T regulatory (Treg) cells have not been fully investigated in patients with systemic sclerosis (SSc). Ten patients with SSc donated 20ml of peripheral blood. Activity (Valentini) and severity (Medsger) scores for SSc were calculated for all patients. Healthy volunteers (controls) were matched to each patient by gender and age. CD4(+) cells were separated using the MACS system. The numbers of Treg cells were estimated by flow cytometry after staining for CD4, CD25, and FoxP3 and calculated as patient-to-control ratio separately for each experiment. Correlations with activity and severity indices of the disease were performed. Twenty-four-hour production of TGF-beta and IL-10 by activated CD4(+) cells was measured by ELISA in culture supernatants. The numbers of Treg cells, expressed as patient-to-control ratio, correlated significantly with both activity and severity indices (r=0.71, p=0.034 and r=0.67, p=0.044, respectively). ELISA-measured production of TGF-beta and IL-10 by CD4(+) cells was similar in patients and controls. Increased numbers of Treg cells are present in patients with SSc, correlating with activity and severity of the disease. This expansion of Treg cells was not accompanied, however, by heightened TGF-beta or IL-10 production. Further studies to elaborate the causes and functional significance of Treg cell expansion in SSc are needed. 2010 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-01-01
... microagglutination test, the enzyme-linked immunosorbent assay test (ELISA), or the rapid serum test for all poultry... react on rapid serum test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that... inhibition (HI) test, the microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA...
USDA-ARS?s Scientific Manuscript database
The antibody is central to the performance of an ELISA providing the basis of analyte selection and detection. It is the interaction of antibody with analyte under defined conditions that dictates the outcome of the ELISA and deviations in those conditions will impact assay performance. The aim of...
BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; MAEDA, Ken; KONDO, Takashi
2015-01-01
To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA. PMID:26424485
Bannai, Hiroshi; Nemoto, Manabu; Tsujimura, Koji; Yamanaka, Takashi; Maeda, Ken; Kondo, Takashi
2016-02-01
To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA.
Estimates of Mumps Seroprevalence May Be Influenced by Antibody Specificity and Serologic Method
McGrew, Marcia; Williams, Nobia J.; Sowers, Sun B.; Bellini, William J.; Hickman, Carole J.
2014-01-01
Neutralizing antibodies are assumed to be essential for protection against mumps virus infection, but their measurement is labor- and time-intensive. For this reason, enzyme-linked immunosorbent assays (ELISAs) are typically used to measure mumps-specific IgG levels. However, since there is poor correlation between mumps neutralization titers and ELISAs that measure the presence of mumps-specific IgG levels, ELISAs that better correlate with neutralization are needed. To address this issue, we measured mumps antibody levels by plaque reduction neutralization, by a commercial ELISA (whole-virus antigen), and by ELISAs specific for the mumps nucleoprotein and hemagglutinin. The results indicate that differences in the antibody response to the individual mumps proteins could partially explain the lack of correlation among various serologic tests. Furthermore, the data indicate that some seropositive individuals have low levels of neutralizing antibody. If neutralizing antibody is important for protection, this suggests that previous estimates of immunity based on whole-virus ELISAs may be overstated. PMID:24371258
A comparison of two antigen-detection ELISA for detecting infection of Dirofilaria immitis in dogs.
Euclid, J M; Copeman, D B
1997-09-01
A survey on 87 dogs necropsied in the Townsville region revealed 34 (39%) were infected with Dirofilaria immitis. Infected dogs had an average of 6.1 adult worms in the heart and associated blood vessels. The VetRED assay detected 23 of the 34 infected dogs (sensitivity 65%) and the Og4C3 ELISA detected 27 (sensitivity 80%). Sensitivity of the VetRED and Og4C3 ELISA increased to 88 and 94% respectively in dogs with three or more worms. Both tests detected correctly all uninfected dogs. Despite the higher accuracy of the Og4C3 ELISA, compared to the VetRED assay, it is unlikely to be used widely as a field test for heartworm unless it can be modified from its present plate ELISA format which takes 4 hours, into one which is more rapid and convenient. However, as a reference ELISA, it may well be worthwhile in situations which require considerable accuracy for detecting D. immitis infection.
Iacono-Connors, L C; Novak, J; Rossi, C; Mangiafico, J; Ksiazek, T
1994-01-01
We developed an antigen capture enzyme-linked immunosorbent assay (ELISA) which does not require purified protective antigen (PA) for detection of human antibodies to Bacillus anthracis PA. Lysates of Spodoptera frugiperda (Sf-9) cells infected with recombinant baculovirus containing the PA gene were used as the source of PA to develop the ELISA. Recombinant PA from crude Sf-9 cell lysates or PA purified from B. anthracis Sterne strain was captured by an anti-PA monoclonal antibody coated onto microtiter plates. We demonstrated that human serum antibody titers to PA were identical in the ELISA whether we used crude Sf-9 cell lysates containing recombinant baculovirus-expressed PA or purified Sterne PA. Finally, false-positive results observed in a direct ELISA were eliminated with this antigen capture ELISA. Thus, the antigen capture ELISA with crude preparations of baculovirus-expressed PA is reliable, safe, and inexpensive for determining anti-PA antibody levels in human sera. PMID:7496927
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Seroprevalence of Toxoplasma gondii in wild kangaroos using an ELISA
Parameswaran, N.; O'Handley, RM.; Grigg, ME.; Fenwick, SG.; Thompson, RCA.
2009-01-01
Infection with Toxoplasma gondii is a significant problem in Australian marsupials, and can lead to devastating disease and predispose animals to predation. T. gondii infection in kangaroos is also of public health significance due to the kangaroo meat trade. A moderate seroprevalence of T. gondii was observed in a study of western grey kangaroos located in the Perth metropolitan area in Western Australia. Of 219 kangaroos tested, 15.5% (95%CI: 10.7-20.3) were positive for T. gondii antibodies using an ELISA developed to detect T. gondii IgG in macropod marsupials. When compared with the commercially available MAT (modified agglutination test), the ELISA developed was in absolute agreement and yielded a κ coefficient of 1.00. Of 18 kangaroos tested for the presence of T. gondii DNA by PCR, the 9 ELISA positive kangaroos tested PCR positive and the 9 ELISA negative kangaroos tested PCR negative indicating the ELISA protocol was both highly specific and sensitive and correlated 100% with the more labour intensive PCR assay. PMID:19567231
Enzyme-linked immunosorbent assay detection and bioactivity of Cry1Ab protein fragments.
Albright, Vurtice C; Hellmich, Richard L; Coats, Joel R
2016-12-01
The continuing use of transgenic crops has led to an increased interest in the fate of insecticidal crystalline (Cry) proteins in the environment. Enzyme-linked immunosorbent assays (ELISAs) have emerged as the preferred detection method for Cry proteins in environmental matrices. Concerns exist that ELISAs are capable of detecting fragments of Cry proteins, which may lead to an overestimation of the concentration of these proteins in the environment. Five model systems were used to generate fragments of the Cry1Ab protein, which were then analyzed by ELISAs and bioassays. Fragments from 4 of the model systems were not detectable by ELISA and did not retain bioactivity. Fragments from the proteinase K model system were detectable by ELISA and retained bioactivity. In most cases, ELISAs appear to provide an accurate estimation of the amount of Cry proteins in the environment, as detectable fragments retained bioactivity and nondetectable fragments did not retain bioactivity. Environ Toxicol Chem 2016;35:3101-3112. © 2016 SETAC. © 2016 SETAC.
Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L
2016-07-01
Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®
2004-01-01
Abstract The objective of this study was to develop and analytically validate an enzyme linked immunosorbent assay (ELISA) for measurement of canine gastric lipase immunoreactivity (cGLI). A sandwich ELISA was developed using canine gastric lipase (cGL) purified from canine stomachs and polyclonal antibodies directed against cGL, raised in rabbits and purified by affinity chromatography. The assay was validated by determination of sensitivity, working range, linearity, accuracy, precision, reproducibility, and the upper limit of the control range by determining the 97.5th percentile of serum cGLI concentration in 74 healthy canines. Sensitivity and working range in serum were 200 ng/L and 200 to 39 160 ng/L, respectively. Observed to expected ratios for dilutional parallelism for 3 serum samples and 3 dilutions ranged from 86.1% to 244.2% (mean ± standard deviation [s]; 125.4% ± 48.2%). Observed to expected ratios for spiking recoveries for 3 serum samples and 6 spiking concentrations ranged from 66.4% to 152.5% (mean ± s; 104.5% ± 22.9%). Intra-assay and interassay variabilities for 3 different serum samples were 25.5%, 9.4%, and 13.4% and 26.0%, 17.2%, and 14.4%, respectively. The upper limit of the control range for serum cGLI was 662 ng/L. We concluded that the ELISA for cGLI described here is highly sensitive and shows a wide working range. However, the validation characteristics for this assay are suboptimal and below values of approximately 2.000 ng/L the assay is more semiquantitative in nature. Despite its limitations, whether this assay is useful for the diagnosis of canine gastric disorders remains to be determined. PMID:15352539
Sanchez, J; Dohoo, I R; Markham, F; Leslie, K; Conboy, G
2002-10-16
An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against Ostertagia ostertagi using a crude adult worm antigen was evaluated using serum and milk samples from adult cows, as well as from bulk tank milk. Within and between plate repeatabilities were determined. In addition, the effects of factors such as antigen batch, freezing, preserving of the samples and somatic cell counts (SCCs) of the samples were evaluated. Raw optical densities (ODs) and normalized values were compared using the concordance correlation coefficient (CCC), the coefficient of variation (CV), Bland-Altman plots (BA). Based on raw OD values, there was a high repeatability within a plate (CCC approximately 0.96 and CV<10%). Repeatability between plates was evaluated following normalization of OD values by four methods. Computing normalized values as (OD-Nt)/(Pst-Nt), gave the most repeatable results, with the CCC being approximately 0.95 and the CV approximately 11%. When the OD values were higher than 1.2 and 0.3 for the positive and the negative controls, respectively, none of the normalization methods evaluated provided highly repeatable results and it was necessary to repeat the test. Two batches of the crude antigen preparation were evaluated for repeatability, and no difference was found (CCC=0.96). The use of preservative (bronopol) did not affect test results, nor did freezing the samples for up to 8 months. A significant positive relationship between ELISA OD for milk samples and SCC score was found. Therefore, the use of composite milk samples, which have less variable SCC than samples taken from each quarter, would be more suitable when the udder health status is unknown. The analytical methods used to evaluate repeatability provided a practical way to select among normalization procedures.
Khatami, Alireza; Seyedin, Zahra; Daneshpazhooh, Maryam
2015-01-01
Background. Serum desmoglein enzyme-linked immunosorbent assay (ELISA) is used for the diagnosis and monitoring of pemphigus diseases. Objectives. To compare the diagnostic accuracy of salivary antidesmoglein (Dsg) 1 and 3 ELISA in the diagnosis of pemphigus vulgaris (PV) patients with that of serum desmogleins ELISA. Methods. Eighty-six untreated PV patients and 180 age- and sex-matched PV-free controls were recruited in this case-control study. PV was diagnosed based on clinical, histopathological, and direct immunofluorescence findings. After processing, serum and salivary anti-Dsg 1 and 3 were measured by the ELISA method using Euroimmun kit (Lübeck, Germany). Results. Using the cut-off point of 20 relative units (RU)/mL, the serum anti-Dsg 1 and 3 ELISA were positive in 62 (72.1%) and 83 (96.5%) patients, respectively, and the salivary anti-Dsg 1 and 3 ELISA were positive in 31 (36.1%) and 63 (73.3%) patients, respectively. The specificity of salivary anti-Dsg 1 and anti-Dsg 3 were both 98.9%. Optimal cut-off values of 7.7 and 13.4 RU/mL were determined for the salivary anti-Dsg 1 and anti-Dsg 3 ELISA, respectively. Conclusion. Salivary anti-Dsg 1 and 3 ELISA with high specificities (98.9%) could be suggested as safe and noninvasive methods for the diagnosis of PV when obtaining a blood sample is difficult. PMID:25688364
Thiha, Aung; Ibrahim, Fatimah
2015-01-01
The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings. PMID:25993517
ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection.
Sun, Steven; Yang, Minghui; Kostov, Yordan; Rasooly, Avraham
2010-08-21
A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.
Enzyme-linked immunosorbent assay for ultratrace determination of antibiotics in aqueous samples.
Kumar, Kuldip; Thompson, Anita; Singh, Ashok K; Chander, Yogesh; Gupta, Satish C
2004-01-01
Two commercially available enzyme-linked immunosorbent assay (ELISA) kits that are commonly used for tylosin or tetracycline residues in meat and milk were adapted for ultratrace analysis of these antibiotics in surface and ground waters. These two antibiotics are commonly fed to swine, turkeys, and cattle at subtherapeutic doses for growth promotion purposes. Both ELISA techniques were found to be highly sensitive and selective for the respective antibiotics with detection limits of 0.10 and 0.05 microg L(-1) for tylosin and tetracycline, respectively. The recovery of both tylosin and tetracycline from spiked samples of lake waters, runoff samples, soil saturation extracts, and nanopure water was close to 100%. Tetracycline ELISA was highly specific for tetracycline and chlortetracycline but not for other forms of tetracycline (oxytetracycline, demeclocycline, and doxycycline). Analysis of a few liquid swine manure samples by liquid chromatography-mass spectrometry (LC-MS) showed lower concentrations for chlortetracycline as compared with concentrations obtained using ELISA. However, the concentrations of tylosin from ELISA were comparable with that of LC-MS. The lower concentrations of chlortetracycline obtained by LC-MS in manure samples indicate the presence of other similar or transformed compounds that were detected by ELISA but not determined by LC-MS. These results indicate that both ELISA kits can be useful tools for low-cost screening of tylosin, tetracycline, and chlortetracycline in environmental waters. Furthermore, both ELISA procedures are rapid, portable, and easily adaptable for testing of multiple samples simultaneously.
77 FR 11137 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-24
... nonspecific, and the diagnosis is frequently difficult and delayed. The inventors established a rapid ELISA assay to evaluate biomarker levels in serum. The ELISA assay tests a novel combination of two biomarkers...-invasive ELISA serum assay. Potential for high sensitivity. Cost effective. Development Stage: Pilot. Early...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
Undergraduate Laboratory Module for Implementing ELISA on the High Performance Microfluidic Platform
ERIC Educational Resources Information Center
Giri, Basant; Peesara, Ravichander R.; Yanagisawa, Naoki; Dutta, Debashis
2015-01-01
Implementing enzyme-linked immunosorbent assays (ELISA) in microchannels offers several advantages over its traditional microtiter plate-based format, including a reduced sample volume requirement, shorter incubation period, and greater sensitivity. Moreover, microfluidic ELISA platforms are inexpensive to fabricate and allow integration of…
A Simple ELISA Exercise for Undergraduate Biology.
ERIC Educational Resources Information Center
Baker, William P.; Moore, Cathy R.
Understanding of immunological techniques such as the Enzyme Linked Immuno Sorbent Assay (ELISA) is an important part of instructional units in human health, developmental biology, microbiology, and biotechnology. This paper describes a simple ELISA exercise for undergraduate biology that effectively simulates the technique using a paper model.…
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
7 CFR 301.92-12 - Testing protocols.
Code of Federal Regulations, 2014 CFR
2014-01-01
.... The following methodology is approved by APHIS. (a) Optional ELISA Prescreening. An APHIS-approved ELISA may be used to prescreen plant samples to determine the presence of Phytophthora spp. (1) Negative... ELISA prescreening, no further testing is required. The nursery may be considered free of evidence of...
Abstract describes the development of an enzyme-linked immunosorbent assay (ELISA) method for monitoring 2,4-dichlorophenoxyacetic acid (2,4-D exposures). The ELISA is compared with a gas chromatograhy/mass spectrometry procedure. ELISA method development steps and comparative ...
Beaver, A; Cazer, C L; Ruegg, P L; Gröhn, Y T; Schukken, Y H
2016-02-01
Mycobacterium avium ssp. paratuberculosis (MAP), the etiologic agent of Johne's disease in dairy cattle, may enter the bulk tank via environmental contamination or direct excretion into milk. Traditionally, diagnostics to identify MAP in milk target either MAP antibodies (by ELISA) or the organism itself (by culture or PCR). High ELISA titers may be directly associated with excretion of MAP into milk but only indirectly linked to environmental contamination of the bulk tank. Patterns of bulk-milk ELISA and bulk-milk PCR results could therefore provide insight into the routes of contamination and level of infection or environmental burden. Coupled with questionnaire responses pertaining to management, the results of these diagnostic tests could reveal correlations with herd characteristics or on-farm practices that distinguish herds with high and low environmental bulk-tank MAP contamination. A questionnaire on hygiene, management, and Johne's specific parameters was administered to 292 dairy farms in New York, Oregon, and Wisconsin. Bulk-tank samples were collected from each farm for evaluation by real-time PCR and ELISA. Before DNA extraction and testing of the unknown samples, bulk-milk template preparation was optimized with respect to parameters such as MAP fractionation patterns and lysis. Two regression models were developed to explore the relationships among bulk-tank PCR, ELISA, environmental predictors, and herd characteristics. First, ELISA optical density (OD) was designated as the outcome in a linear regression model. Second, the log odds of being PCR positive in the bulk tank were modeled using binary logistic regression with penalized maximum likelihood. The proportion of PCR-positive bulk tanks was highest for New York and for organic farms, providing a clue as to the geographical patterns of MAP-positive bulk-tank samples and relationship to production type. Bulk-milk PCR positivity was also higher for large relative to small herds. The models revealed that bulk-milk PCR result could predict ELISA OD, with PCR-positive results corresponding to high bulk-milk ELISA titers. Similarly, ELISA was a predictor of PCR result, although the association was stronger for organic farms. Despite agreement between high bulk-milk ELISA titers and positive PCR results, a large proportion of high ELISA farms had PCR-negative bulk tanks, suggesting that farms are able to maintain satisfactory hygiene and management despite a presence of MAP in these herds. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Staphylococcus aureus is a major causative agent implicated in outbreaks of food poisoning, acting through the production of a range of toxins including staphylococcal enterotoxin type E (SEE). While tests such as enzyme-linked immunosorbent (ELISA) exist to detect the toxin molecules, existing meth...
Evaluation of commercial a-amylase enzyme-linked immunosorbent assy (ELISA) test kits for wheat
USDA-ARS?s Scientific Manuscript database
a-Amylase enzyme is associated with preharvest sprouting (PHS) and late-maturity a amylase (LMA) in wheat, and reduces wheat and flour quality. Various means have been developed to measure the presence of a-amylase, thereby predicting end-use quality; most are based on enzyme activity. An alternativ...
Aburto-Mejía, Elsa; Santiago-Germán, David; Martínez-Marino, Manuel; María Eugenia Galván-Plata; Almeida-Gutiérrez, Eduardo; Hernández-Juárez, Jesús; Alvarado-Moreno, Antonio; Leaños-Miranda, Alfredo
2017-01-01
Background. Metabolic and genetic factors induce plasminogen activator inhibitor type-1 (PAI-1) overexpression; higher PAI-1 levels decrease fibrinolysis and promote atherothrombosis. Aim. To assess PAI-1 antigen levels among subjects with type 2 diabetes mellitus (T2DM) plus Metabolic Syndrome (MetS) before clinical manifestations of atherothrombosis and the contribution of metabolic factors and 4G/5G polymorphism of PAI-1 gene on the variability of PAI-1. Methods. We conducted an observational, cross-sectional assay in a hospital in Mexico City from May 2010 to September 2011. MetS was defined by the International Diabetes Federation criteria. PAI-1 levels and 4G/5G polymorphism were determined by ELISA and PCR-RFLP analysis. Results. We enrolled 215 subjects with T2DM plus MetS and 307 controls. Subjects with T2DM plus MetS had higher PAI-1 levels than the reference group (58.4 ± 21 versus 49.9 ± 16 ng/mL, p = 0.026). A model with components of MetS explained only 12% of variability on PAI-1 levels (R2 = 0.12; p = 0.001), with β = 0.18 (p = 0.03) for hypertension, β = −0.16 (p = 0.05) for NL HDL-c, and β = 0.15 (p = 0.05) for NL triglycerides. Conclusion. Subjects with T2DM plus MetS have elevated PAI-1 levels before clinical manifestations of atherothrombotic disease. Metabolic factors have a more important contribution than 4G/5G polymorphism on PAI-1 plasma variability. PMID:28271069
Muenchhoff, Maximilian; Healy, Michael; Singh, Ravesh; Roider, Julia; Groll, Andreas; Kindra, Chirjeev; Sibaya, Thobekile; Moonsamy, Angeline; McGregor, Callum; Phan, Michelle Q; Palma, Alejandro; Kloverpris, Henrik; Leslie, Alasdair; Bobat, Raziya; LaRussa, Philip; Ndung'u, Thumbi; Goulder, Philip; Sobieszczyk, Magdalena E; Archary, Mohendran
2018-01-01
This observational study aimed to describe immunopathogenesis and treatment outcomes in children with and without severe acute malnutrition (SAM) and HIV-infection. We studied markers of microbial translocation (16sDNA), intestinal damage (iFABP), monocyte activation (sCD14), T-cell activation (CD38, HLA-DR) and immune exhaustion (PD1) in 32 HIV-infected children with and 41 HIV-infected children without SAM prior to initiation of antiretroviral therapy (ART) and cross-sectionally compared these children to 15 HIV-uninfected children with and 19 HIV-uninfected children without SAM. We then prospectively measured these markers and correlated them to treatment outcomes in the HIV-infected children at 48 weeks following initiation of ART. Plasma levels of 16sDNA, iFABP and sCD14 were measured by quantitative real time PCR, ELISA and Luminex, respectively. T cell phenotype markers were measured by flow cytometry. Multiple regression analysis was performed using generalized linear models (GLMs) and the least absolute shrinkage and selection operator (LASSO) approach for variable selection. Microbial translocation, T cell activation and exhaustion were increased in HIV-uninfected children with SAM compared to HIV-uninfected children without SAM. In HIV-infected children microbial translocation, immune activation, and exhaustion was strongly increased but did not differ by SAM-status. SAM was associated with increased mortality rates early after ART initiation. Malnutrition, age, microbial translocation, monocyte, and CD8 T cell activation were independently associated with decreased rates of CD4% immune recovery after 48 weeks of ART. SAM is associated with increased microbial translocation, immune activation, and immune exhaustion in HIV-uninfected children and with worse prognosis and impaired immune recovery in HIV-infected children on ART.
Hom, Sarah; Chen, Li; Wang, Tony; Ghebrehiwet, Berhane; Yin, Wei; Rubenstein, David A
2016-11-01
Tobacco smoke extracts prepared from both mainstream and sidestream smoking have been associated with heightened platelet activation, aggregation, adhesion, and inflammation. Conversely, it has been shown that pure nicotine inhibits similar platelet functions. In this work, we 1) evaluated the effects of e-cigarette extracts on platelet activities and 2) elucidated the differences between the nicotine-dependent and non-nicotine dependent (e.g. fine particulate matter or toxic compounds) effects of tobacco and e-cigarette products on platelet activities. To accomplish these goals, platelets from healthy volunteers (n = 50) were exposed to tobacco smoke extracts, e-cigarette vapor extracts, and pure nicotine and changes in platelet activation, adhesion, aggregation, and inflammation were evaluated, using optical aggregation, flow cytometry, and ELISA methods. Interestingly, the exposure of platelets to e-vapor extracts induced a significant up-regulation in the expression of the pro-inflammatory gC1qR and cC1qR and induced a marked increase in the deposition of C3b as compared with traditional tobacco smoke extracts. Similarly, platelet activation, as measured by a prothrombinase based assay, and platelet aggregation were also significantly enhanced after exposure to e-vapor extracts. Finally, platelet adhesion potential toward fibrinogen, von Willebrand factor, and other platelets was also enhanced after exposure to e-cigarette vapor extracts. In the presence of pure nicotine, platelet functions were observed to be inhibited, which further suggests that other constituents of tobacco smoke and electronic vapor can antagonize platelet functions, however, the presence of nicotine in extracts somewhat perpetuated the platelet functional changes in a dose-dependent manner.
Healy, Michael; Singh, Ravesh; Roider, Julia; Groll, Andreas; Kindra, Chirjeev; Sibaya, Thobekile; Moonsamy, Angeline; McGregor, Callum; Phan, Michelle Q.; Palma, Alejandro; Kloverpris, Henrik; Leslie, Alasdair; Bobat, Raziya; LaRussa, Philip; Ndung'u, Thumbi; Goulder, Philip; Sobieszczyk, Magdalena E.; Archary, Mohendran
2018-01-01
Abstract This observational study aimed to describe immunopathogenesis and treatment outcomes in children with and without severe acute malnutrition (SAM) and HIV-infection. We studied markers of microbial translocation (16sDNA), intestinal damage (iFABP), monocyte activation (sCD14), T-cell activation (CD38, HLA-DR) and immune exhaustion (PD1) in 32 HIV-infected children with and 41 HIV-infected children without SAM prior to initiation of antiretroviral therapy (ART) and cross-sectionally compared these children to 15 HIV-uninfected children with and 19 HIV-uninfected children without SAM. We then prospectively measured these markers and correlated them to treatment outcomes in the HIV-infected children at 48 weeks following initiation of ART. Plasma levels of 16sDNA, iFABP and sCD14 were measured by quantitative real time PCR, ELISA and Luminex, respectively. T cell phenotype markers were measured by flow cytometry. Multiple regression analysis was performed using generalized linear models (GLMs) and the least absolute shrinkage and selection operator (LASSO) approach for variable selection. Microbial translocation, T cell activation and exhaustion were increased in HIV-uninfected children with SAM compared to HIV-uninfected children without SAM. In HIV-infected children microbial translocation, immune activation, and exhaustion was strongly increased but did not differ by SAM-status. SAM was associated with increased mortality rates early after ART initiation. Malnutrition, age, microbial translocation, monocyte, and CD8 T cell activation were independently associated with decreased rates of CD4% immune recovery after 48 weeks of ART. SAM is associated with increased microbial translocation, immune activation, and immune exhaustion in HIV-uninfected children and with worse prognosis and impaired immune recovery in HIV-infected children on ART. PMID:28670966
2016-08-01
platforms. 15. SUBJECT TERMS Antibody Antibody Technology Program (ATP) Quality Enzyme-linked immunosorbent assay ( ELISA ) Biosurveillance Single-chain...2.6 Thermal Stress Test............................................................................................4 2.7 ELISA ...3.5 ELISA Results .................................................................................................11 3.6 SPR Results
42 CFR 71.53 - Requirements for importers of nonhuman primates.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Trade in Endangered Species. ELISA means enzyme-linked immunosorbent assay, a type of laboratory test... serum for immunoglobulin G (IgG) antibodies to filovirus by using an ELISA methodology, or other method... for filovirus antigen by using the antigen-capture ELISA method must be submitted to a qualified...
Assessment of an ELISA Laboratory Exercise
ERIC Educational Resources Information Center
Robinson, David L.; Lau, Joann M.
2012-01-01
The enzyme-linked immunosorbent assay (ELISA) is a powerful immunological technique for quantifying small amounts of compounds and has been used in research and clinical settings for years. Although there are laboratory exercises developed to introduce the ELISA technique to students, their ability to promote student learning has not been…
Code of Federal Regulations, 2014 CFR
2014-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
42 CFR 71.53 - Requirements for importers of nonhuman primates.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Trade in Endangered Species. ELISA means enzyme-linked immunosorbent assay, a type of laboratory test... serum for immunoglobulin G (IgG) antibodies to filovirus by using an ELISA methodology, or other method... for filovirus antigen by using the antigen-capture ELISA method must be submitted to a qualified...
76 FR 15791 - National Poultry Improvement Plan and Auxiliary Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-22
... microhemagglutination inhibition test, the enzyme-linked immunosorbent assay (ELISA) test,\\3\\ a polymerase chain [[Page... samplings and/or culture of reactors. \\3\\ Procedures for the enzyme-linked immunosorbent assay (ELISA) test... Immunosorbent Assay (ELISA),'' Proceedings, 30th Western Poultry Disease Conference, pp. 63-66, March 1981...
Code of Federal Regulations, 2012 CFR
2012-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
Code of Federal Regulations, 2013 CFR
2013-01-01
... immunosorbent assay test (ELISA), or the rapid serum test for all poultry; and the stained antigen, rapid whole... test or enzyme-labeled immunosorbent assay test (ELISA), or blood from birds that react on the stained... enzyme-linked immunosorbent assay (ELISA) test,3 a polymerase chain reaction (PCR)-based test, or a...
An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...
Abstract describes a streamlined ELISA method developed to quantitatively measure 2,4-D in human urine samples. Method development steps and comparison with gas chromatography/mass spectrometry are presented. Results indicated that the ELISA method could be used as a high throu...
Kai, Junhai; Puntambekar, Aniruddha; Santiago, Nelson; Lee, Se Hwan; Sehy, David W; Moore, Victor; Han, Jungyoup; Ahn, Chong H
2012-11-07
In this work we introduce a novel microfluidic enzyme linked immunoassays (ELISA) microplate as the next generation assay platform for unparalleled assay performances. A combination of microfluidic technology with standard SBS-configured 96-well microplate architecture, in the form of microfluidic microplate technology, allows for the improvement of ELISA workflows, conservation of samples and reagents, improved reaction kinetics, and the ability to improve the sensitivity of the assay by multiple analyte loading. This paper presents the design and characterization of the microfluidic microplate, and its application in ELISA.
Parreiras, P M; Sirota, L A; Wagner, L D; Menzies, S L; Arciniega, J L
2009-07-16
Complexities of lethal challenge models have prompted the investigation of immunogenicity assays as potency tests of anthrax vaccines. An ELISA and a lethal toxin neutralization assay (TNA) were used to measure antibody response to Protective Antigen (PA) in mice immunized once with either a commercial or a recombinant PA (rPA) vaccine formulated in-house. Even though ELISA and TNA results showed correlation, ELISA results may not be able to accurately predict TNA results in this single immunization model.
Generation and Characterization of Protective Antibodies to Marburg Virus
2017-04-03
of cells following viral replication of the complex. The macaque developed increasing anti-GP Ab titers as evaluated by ELISA with a titer of 1:12800...those of the author and are not necessarily endorsed by the U.S. Army. SUPPLEMENTAL DATA: Table S-1. ELISA serum titer response following each...x 400 µL at 0.9x109 VRP/mL ELISA Titer (GP) NT >1/316,000 1/500,000 NT ELISA Titer (Live Virus) NT >1/316,000 1/450,000 NT Table S-2
Kanabagatte Basavarajappa, Mallikarjuna; Song, Haichen; Lamichhane, Chinta; Samal, Siba K
2015-05-01
For detection of infectious laryngotracheitis virus (ILTV) antibody, glycoprotein B-, C-, and D-based enzyme-linked immunosorbent assays (B-, C-, and D-ELISAs, respectively) were developed. The B- and D-ELISAs showed enhanced detection of anti-ILTV antibodies in infected chickens compared to that of the commercial ELISA. Furthermore, the D-ELISA was efficient in detecting seroconversion with vectored vaccine, using recombinant Newcastle disease virus (rNDV) expressing glycoprotein D (gD) as the vaccine vector. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Seroprevalence of Toxoplasma gondii in southern districts of Tamil Nadu using IgG-ELISA.
Sucilathangam, G; Palaniappan, N; Sreekumar, C; Anna, T
2012-10-01
The present study was conducted to assess the seroprevalence of Toxoplasma gondii in and around Tirunelveli by in-house IgG assay using ELISA. Serum samples from 175 immunodeficient and 175 immunocompetent patients were collected at Tirunelveli district, Tamil Nadu from May 2006 to October 2007. They were subjected into in-house IgG assay using enzyme-linked immune sorbent assay (ELISA) in which tachyzoite soluble antigen derived from solubilised whole organisms was used. Out of 350 patients tested by IgG ELISA, 46 patients (13.14%) had antibodies for toxoplasmosis with mean OD value of 0.2 ± 0.073 and the OD value ranged from 0.144 to 0.444. Among the immunocompetent group of 175 patients, 19 patients (10.86%) had antibodies to toxoplasmosis whereas, in immunodeficient group of 175 patients, 27 patients (15.43%) had antibodies for toxoplasmosis. There was no statistical difference (P > 0.05) between the immunocompetent and immunodeficient group. The sensitivity and specificity of IgG ELISA in detecting toxoplasmosis was 90 and 100%, respectively. The overall seroprevalence of toxoplasmosis in and around Tirunelveli district of Tamil Nadu was 13.14% based on IgG ELISA. The study has proved ELISA to be a sensitive and specific procedure for the serodiagnosis of toxoplasmosis.
Serodiagnosis of Toxocariasis by ELISA Using Crude Antigen of Toxocara canis Larvae
Jin, Yan; Shen, Chenghua; Huh, Sun; Sohn, Woon-Mok; Choi, Min-Ho
2013-01-01
Toxocariasis is a worldwide zoonosis caused by larvae of ascarid nematodes of dogs or cats, Toxocara canis or T. cati. Diagnosis of human toxocariasis currently relies on serology that uses T. canis excretory-secretory antigen to detect specific IgG antibodies by ELISA. We investigated the serodiagnostic efficacy of ELISA using crude antigen of T. canis larvae (TCLA). Serum specimens of 64 clinically confirmed toxocariasis, 115 healthy controls, and 119 other tissue-invading helminthiases were screened by ELISA using TCLA. The ELISA using TCLA showed 92.2% (59/64 patient samples) sensitivity and 86.6% (103/119) specificity. Its positive diagnostic predictivity was 78.7% and negative predictivity was 97.8%. No serum of healthy controls reacted but that of anisakiasis (45.5%), gnathostomiasis (19.2%), clonorchiasis (15.8%), sparganosis (11.1%), and cysticercosis (6.3%) cross-reacted. Immunoblot analysis on TCLA recognized antigenic proteins of 28- and 30-kDa bands in their dominant protein quantity and strong blotting reactivity. The present results indicate that the ELISA using our TCLA antigen is acceptable by the sensitivity and specificity for serodiagnosis of human toxocariasis. ELISA with TCLA is recommended to make differential diagnosis for patients with any sign of organ infiltration and eosinophilia. PMID:24039286
Benkirane, S; Nicolas, A; Galteau, M M; Siest, G
1991-06-01
Two immuno-assay methods (RIA and ELISA) have been developed for the accurate and sensitive measurement of cotinine in human body fluids (serum, saliva). RIA uses [3H]cotinine as antigen and charcoal/dextran for separating cotinine-bound antibodies from the free derivative. Another technique (ELISA) was developed to avoid the use of radio-labelled compounds and to determine cotinine in large populations, including passive or non-smokers who usually present very low concentrations. The two techniques were analytically validated. The detection limit was similar (0.1 micrograms/l) and the precision was better than 10% for both techniques. Non-smoker values ranged from 0.1 to 17 micrograms/l by ELISA and 0.1 to 27.5 micrograms/l by RIA, whereas smoker values ranged from 50 to 1000 micrograms/l (ELISA) and from 70 to 800 micrograms/l (RIA). The comparative analysis of cotinine in 96 human sera revealed a good correlation between the two methods (r = 0.97) and a reliable discrimination between the populations of non-smokers and smokers. As usual, the ELISA is more rapid (4 h 30 min) than the RIA (longer than 48 h). ELISA is proposed for use in the epidemiological investigation of the human tobacco risk.
Khan, Mohsin; Dhanwani, Rekha; Kumar, Jyoti S; Rao, P V Lakshmana; Parida, Manmohan
2014-07-01
Despite the fact that Chikungunya resurgence is associated with epidemic of unprecedented magnitude, there are challenges in the field of its clinical diagnosis. However, serological tests in an ELISA format provide a rapid tool for the diagnosis of Chikungunya infection. Indeed, ELISAs based on recombinant proteins hold a great promise as these methods are cost effective and are free from the risk of handling biohazardous material. In this study, the performance of recombinant CHIKV antigens was compared in various ELISA formats for the diagnosis of Chikungunya. Two recombinant antigens derived from the envelope proteins of Chikungunya virus were prepared and evaluated by comparing their competence for detecting circulating antibodies in serum samples of patients infected with CHIKV using MAC-ELISA and indirect IgM-ELISA. The efficacy of the recombinant antigens was also compared with the native antigen. The indirect antibody capture IgM microplate ELISA revealed ≥90% concordance with the native antigen in detecting the CHIKV specific IgM antibodies whereas the recombinant antigen based MAC-ELISA showed 100% specificity. The recombinant antigens used in this study were effective and reliable targets for the diagnosis of CHIKV infection and also provide an alternative for native antigen use which is potentially biohazardous. © 2013 Wiley Periodicals, Inc.
G-protein based ELISA as a potency test for rabies vaccines.
Chabaud-Riou, Martine; Moreno, Nadège; Guinchard, Fabien; Nicolai, Marie Claire; Niogret-Siohan, Elisabeth; Sève, Nicolas; Manin, Catherine; Guinet-Morlot, Françoise; Riou, Patrice
2017-03-01
The NIH test is currently used to assess the potency of rabies vaccine, a key criterion for vaccine release. This test is based on mice immunization followed by intracerebral viral challenge. As part of global efforts to reduce animal experimentation and in the framework of the development of Sanofi Pasteur next generation, highly-purified vaccine, produced without any material of human or animal origin, we developed an ELISA as an alternative to the NIH test. This ELISA is based on monoclonal antibodies recognizing specifically the native form of the viral G-protein, the major antigen that induces neutralizing antibody response to rabies virus. We show here that our ELISA is able to distinguish between potent and different types of sub-potent vaccine lots. Satisfactory agreement was observed between the ELISA and the NIH test in the determination of the vaccine titer and their capacity to discern conform from non-conform batches. Our ELISA meets the criteria for a stability-indicating assay and has been successfully used to develop the new generation of rabies vaccine candidates. After an EPAA international pre-collaborative study, this ELISA was selected as the assay of choice for the EDQM collaborative study aimed at replacing the rabies vaccine NIH in vivo potency test. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
An enzyme-linked immunosorbent assay for detection of botulinum toxin-antibodies.
Dressler, Dirk; Gessler, Frank; Tacik, Pawel; Bigalke, Hans
2014-09-01
Antibodies against botulinum neurotoxin (BNT-AB) can be detected by the mouse protection assay (MPA), the hemidiaphragm assay (HDA), and by enzyme-linked immunosorbent assays (ELISA). Both MPA and HDA require sacrifice of experimental animals, and they are technically delicate and labor intensive. We introduce a specially developed ELISA for detection of BNT-A-AB and evaluate it against the HDA. Thirty serum samples were tested by HDA and by the new ELISA. Results were compared, and receiver operating characteristic analyses were used to optimize ELISA parameter constellation to obtain either maximal overall accuracy, maximal test sensitivity, or maximal test specificity. When the ELISA is optimized for sensitivity, a sensitivity of 100% and a specificity of 55% can be reached. When it is optimized for specificity, a specificity of 100% and a sensitivity of 90% can be obtained. We present an ELISA for BNT-AB detection that can be-for the first time-customized for special purposes. Adjusted for optimal sensitivity, it reaches the best sensitivity of all BNT-AB tests available. Using the new ELISA together with the HDA as a confirmation test allows testing for BNT-AB in large numbers of patients receiving BT drugs in an economical, fast, and more animal-friendly way. © 2014 International Parkinson and Movement Disorder Society.
Rhee, Jae-Sung; Kim, Bo-Mi; Jeong, Chang-Bum; Leung, Kenneth Mei Yee; Park, Gyung Soo; Lee, Jae-Seong
2013-11-01
To utilize the GST-S protein as a useful biomarker for environmental contamination, we developed a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA) in the intertidal copepod Tigriopus japonicus. Two polyclonal antibodies, TJ-GST-S1 and TJ-GST-S2, were raised against two TJ-GST-S synthetic peptides. Also a recombinant TJ-GST-S protein was purified as a standard for ELISA development. Each polyclonal antibody was tested by Western blot analysis and indirect ELISA. Of two polyclonal antibodies, TJ-GST-S2 ELISA was further employed due to its wide range of detection and the limit of specificity compared to those of TJ-GST-S1 ELISA system. After exposure to 4 metals (Ag, As, Cd, and Cu) to T. japonicus, the amount of TJ-GST-S protein was significantly elevated in a concentration-dependent manner. Also, TJ-GST-S protein was upregulated at relative high concentrations of B[α]P, PCB, and TBT. In this paper, we suggest that T. japonicas ELISA for TJ-GST-S2 is useful as a potential indicator system for marine contaminants. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kwenti, Tebit Emmanuel; Njunda, Longdoh Anna; Tsamul, Beltine; Nsagha, Shey Dickson; Assob, Nguedia Jules-Clement; Tufon, Kukwah Anthony; Meriki, Dilonga Henry; Orock, Enow George
2017-08-01
In malaria endemic areas, infected blood donors serve as a source of infection to blood recipients, which may adversely affect their prognosis. This necessitates the proper screening of blood to be used for transfusion in these areas. The purpose of this study was to determine the prevalence of malaria parasitaemia in blood donors in Buea, Cameroon, and to evaluate the performance of a rapid diagnostic test (RDT), a malaria antibody enzyme-linked immunosorbent assay (ELISA), and a Plasmodium lactate dehydrogenase (pLDH) ELISA in the detection of asymptomatic malaria parasitaemia in the target population. In a prospective study conducted between September 2015 and June 2016, 1 240 potential blood donors were enrolled. The donors were screened for malaria parasites using Giemsa microscopy (GM) and a RDT. A sub-sample of 184 samples, comprising 88 positive and 96 negative samples, were selected for the evaluation of the pLDH ELISA and the antibody ELISA. The chi-square test and correlation analysis were performed as part of the statistical analyses. The statistical significance cut-off was set at P < 0.05. The prevalence of malaria parasitaemia in this study was found to be 8.1% (95% CI: 6.6 - 9.7). The prevalence was not observed to be dependent on the age or sex of the participants. The RDT had a sensitivity (88.0%), specificity (99.1%), and negative predictive value (99.0%) higher than the ELISAs. The performance of the pLDH ELISA, which demonstrated the highest positive predictive value (91.6%), was generally comparable to the RDT. The sensitivity was lowest with the antibody ELISA (69.9%), which also demonstrated the highest false positive and false negative rates. The detection threshold for the pLDH (three parasites/μl) was lower compared to the RDT (50 - 60 parasites/μl). Non-significant positive correlations were observed between the parasite density and the pLDH titers and malaria antibody titers. Overall, the RDT and the pLDH ELISA demonstrated a perfectly correlated agreement with GM, meanwhile the antibody ELISA demonstrated a substantially correlated agreement with GM. The pLDH is therefore recommended for mass screening of blood (to detect malaria parasitaemia) for transfusions in the study area. However, where this is not feasible, an RDT will suffice.
Tothiam, Charinrat; Phrompittayarat, Watoo; Putalun, Waraporn; Tanaka, Hiroyuki; Sakamoto, Seiichi; Khan, Ikhlas A; Ingkaninan, Kornkanok
2011-01-01
In Ayurvedic medicines, Bacopa monnieri (L.) Wettst. (brahmi) is known as a medicinal plant used for memory enhancement. Its active compounds are classified as pseudojujubogenin and jujubogenin glycosides. Owing to the lack of chromophore in the saponin glycoside structures, HPLC-UV-vis gives low sensitivity for determination of such compounds. In the case of the detection of small amounts of saponin glycosides, immunological assay could be a suitable method. To develop and validate a sensitive enzyme-linked immunosorbant assay (ELISA) using monoclonal antibody (MAb) against bacoside A₃, the major jujubogenin glycoside found in brahmi. An immunogen was prepared by conjugating bacoside A₃ with a bovine serum albumin (BSA). To determine its immunogenicity, the ratio of hapten in bacoside A₃-BSA conjugate was determined by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF-MS). After immunisation in mice, hybridomas secreting MAbs against bacoside A₃ were produced by fusing the immunised splenocytes with SP2/0- Ag14 myeloma cells. The antibody was raised specifically against jujubogenin glycosides. The ELISA using anti-bacoside A₃ MAb was developed. Bacoside A₃ in the range of 3.05-97.70 ng mL⁻¹ could be detected by ELISA using anti-bacoside A₃ MAb. The assay showed a detection limit of 0.48 ng mL⁻¹ (0.517 nm). The validation study showed that the method was precise, accurate and sensitive. Interestingly, the MAb showed cross-reactivity with the other jujubogenin glycosides, bacopaside X and IV. However, it did not show cross-reactivity with any of pseudojujubogenin glycosides. The study demonstrated that ELISA using anti-bacoside A₃ MAb can be used for determination of total jujubogenin glycosides in brahmi. Copyright © 2011 John Wiley & Sons, Ltd.
Knapp, Jenny; Sako, Yasuhito; Grenouillet, Frédéric; Bresson-Hadni, Solange; Richou, Carine; Gbaguidi-Haore, Houssein; Ito, Akira; Millon, Laurence
2014-01-01
Serological diagnosis of alveolar echinococcosis (AE) is a key element for efficient patient treatment management. A rapid immunochromatography test kit (ICT) using the recombinant Em18 antigen (rEm18) was recently developed. The aim of our study was to assess this test on a panel of sera from French patients with alveolar echinococcosis and control patients. In a blind test, a total of 112 serum samples were tested including samples of AE (n = 30), cystic echinococcosis [CE] (n = 15), and polycystic echinococcosis [PE] (n = 1). For the comparison, 66 sera from patients with hepatocarcinoma, fascioliasis, toxocariasis, Caroli’s disease, or autoimmune chronic active hepatitis were used. The diagnostic test sets we used were the rEm18-ICT and two validated ELISAs with rEm18 and Em2-Em18 antigens, respectively. For the ICT, 27/30 sera from AE patients, 4/15 sera from CE patients and the PE patient serum were positive. One serum from the control panel (toxocariasis) was positive for the ICT. The rEm18-ICT sensitivity (90.0%) and specificity (92.7%) for detection of Em18-specific antibodies confirmed it as a relevant tool for AE diagnosis. The rEm18-ELISA had a sensitivity of 86.7% and specificity of 91.5%, and the Em2-Em18-ELISA had a sensitivity of 96.7% and specificity of 87.8%. However, when AE patient sera are recorded as weak in intensity with the ICT, we recommend a double reading and use of a reference sample if the ICT is used for patient follow-up. PMID:25058754
Knapp, Jenny; Sako, Yasuhito; Grenouillet, Frédéric; Bresson-Hadni, Solange; Richou, Carine; Gbaguidi-Haore, Houssein; Ito, Akira; Millon, Laurence
2014-01-01
Serological diagnosis of alveolar echinococcosis (AE) is a key element for efficient patient treatment management. A rapid immunochromatography test kit (ICT) using the recombinant Em18 antigen (rEm18) was recently developed. The aim of our study was to assess this test on a panel of sera from French patients with alveolar echinococcosis and control patients. In a blind test, a total of 112 serum samples were tested including samples of AE (n = 30), cystic echinococcosis [CE] (n = 15), and polycystic echinococcosis [PE] (n = 1). For the comparison, 66 sera from patients with hepatocarcinoma, fascioliasis, toxocariasis, Caroli's disease, or autoimmune chronic active hepatitis were used. The diagnostic test sets we used were the rEm18-ICT and two validated ELISAs with rEm18 and Em2-Em18 antigens, respectively. For the ICT, 27/30 sera from AE patients, 4/15 sera from CE patients and the PE patient serum were positive. One serum from the control panel (toxocariasis) was positive for the ICT. The rEm18-ICT sensitivity (90.0%) and specificity (92.7%) for detection of Em18-specific antibodies confirmed it as a relevant tool for AE diagnosis. The rEm18-ELISA had a sensitivity of 86.7% and specificity of 91.5%, and the Em2-Em18-ELISA had a sensitivity of 96.7% and specificity of 87.8%. However, when AE patient sera are recorded as weak in intensity with the ICT, we recommend a double reading and use of a reference sample if the ICT is used for patient follow-up. © J. Knapp et al., published by EDP Sciences, 2014.
de Silva, Thushan I; Gould, Victoria; Mohammed, Nuredin I; Cope, Alethea; Meijer, Adam; Zutt, Ilse; Reimerink, Johan; Kampmann, Beate; Hoschler, Katja; Zambon, Maria; Tregoning, John S
2017-10-01
We need greater understanding of the mechanisms underlying protection against influenza virus to develop more effective vaccines. To do this, we need better, more reproducible methods of sampling the nasal mucosa. The aim of the current study was to compare levels of influenza virus A subtype-specific IgA collected using three different methods of nasal sampling. Samples were collected from healthy adult volunteers before and after LAIV immunization by nasal wash, flocked swabs and Synthetic Absorptive Matrix (SAM) strips. Influenza A virus subtype-specific IgA levels were measured by haemagglutinin binding ELISA or haemagglutinin binding microarray and the functional response was assessed by microneutralization. Nasosorption using SAM strips lead to the recovery of a more concentrated sample of material, with a significantly higher level of total and influenza H1-specific IgA. However, an equivalent percentage of specific IgA was observed with all sampling methods when normalized to the total IgA. Responses measured using a recently developed antibody microarray platform, which allows evaluation of binding to multiple influenza strains simultaneously with small sample volumes, were compared to ELISA. There was a good correlation between ELISA and microarray values. Material recovered from SAM strips was weakly neutralizing when used in an in vitro assay, with a modest correlation between the level of IgA measured by ELISA and neutralization, but a greater correlation between microarray-measured IgA and neutralizing activity. In conclusion we have tested three different methods of nasal sampling and show that flocked swabs and novel SAM strips are appropriate alternatives to traditional nasal washes for assessment of mucosal influenza humoral immunity. Copyright © 2017 Elsevier B.V. All rights reserved.
Eydoux, Cécilia; Aloulou, Ahmed; De Caro, Josiane; Grandval, Philippe; Laugier, René; Carrière, Frédéric; De Caro, Alain
2006-10-01
Human pancreatic lipase-related protein 2 (HPLRP2) was previously found to be secreted by the exocrine pancreas. HPLRP2 shows a high level of activity on galactolipids, and might be involved in the digestion of these common vegetable lipids. Specific antibodies were raised in rabbits using a synthetic HPLRP2 peptide selected for its weak amino acid homology with the corresponding peptides of classical human pancreatic lipase (HPL) and human pancreatic lipase-related protein 1 (HPLRP1). ELISA and Western blotting data showed that these antibodies did not react with HPL or HPLRP1. Various tissues from the digestive tract were subjected to Western blotting analysis with the specific anti-peptide HPLRP2 antibody and the expression of HPLRP2 was detected in the pancreas and colon. An ELISA was developed for specifically measuring the HPLRP2 levels in pure pancreatic juice. This procedure was performed using the anti-peptide HPLRP2 antibody as the captor antibody and a biotinylated anti-HPLRP2 polyclonal antibody as the detector antibody. The lowest HPLRP2 quantification limit was found to be 50 microg/L and the reference range for the present assay was 50 microg-500 microg/L. HPL and HPLRP2 levels were measured using specific ELISAs in pancreatic juice from patients with and without pancreatic disorders. Patients with chronic calcifying pancreatitis (CCP) had significantly lower levels of both HPL and HPLRP2 than the controls subjects. The mean HPLRP2 to HPL ratio was estimated to be 28.30% (w/w) and 23.96% (w/w) in controls subjects and CCP patients, respectively, and the difference was not significant. The levels of HPL and HPLRP2 are therefore similarly reduced in both healthy patients and CCP patients.
Attallah, Abdelfattah M.; Bughdadi, Faisal A.; El-Shazly, Atef M.
2013-01-01
Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P < 0.0001) for discriminating Fasciola-infected and noninfected individuals. The developed assay showed high degrees of sensitivity, specificity, and efficiency (>93%), and a significant correlation (r = 0.715, P < 0.0001) between antigen level and parasite egg count was shown. In conclusion, a 27-kDa Fasciola antigen was identified in sera of F. gigantica-infected individuals. A highly sensitive and specific Fasciola antigen detection assay, FgCA-27 ELISA, was developed for laboratory diagnosis of human fascioliasis. PMID:23945158
Attallah, Abdelfattah M; Bughdadi, Faisal A; El-Shazly, Atef M; Ismail, Hisham
2013-10-01
Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P < 0.0001) for discriminating Fasciola-infected and noninfected individuals. The developed assay showed high degrees of sensitivity, specificity, and efficiency (>93%), and a significant correlation (r = 0.715, P < 0.0001) between antigen level and parasite egg count was shown. In conclusion, a 27-kDa Fasciola antigen was identified in sera of F. gigantica-infected individuals. A highly sensitive and specific Fasciola antigen detection assay, FgCA-27 ELISA, was developed for laboratory diagnosis of human fascioliasis.
Marchán, Daniel F; Fernández, Rosa; de Sosa, Irene; Díaz Cosín, Darío J; Novo, Marta
2017-07-01
Spatial and temporal aspects of the evolution of cryptic species complexes have received less attention than species delimitation within them. The phylogeography of the cryptic complex Hormogaster elisae (Oligochaeta, Hormogastridae) lacks knowledge on several aspects, including the small-scale distribution of its lineages or the palaeogeographic context of their diversification. To shed light on these topics, a dense specimen collection was performed in the center of the Iberian Peninsula - resulting in 28 new H. elisae collecting points, some of them as close as 760m from each other- for a higher resolution of the distribution of the cryptic lineages and the relationships between the populations. Seven molecular regions were amplified: mitochondrial subunit 1 of cytochrome c oxidase (COI), 16S rRNA and tRNA Leu, Ala, and Ser (16S t-RNAs), one nuclear ribosomal gene (a fragment of 28S rRNA) and one nuclear protein-encoding gene (histone H3) in order to infer their phylogenetic relationships. Different representation methods of the pairwise divergence in the cytochrome oxidase I sequence (heatmap and genetic landscape graphs) were used to visualize the genetic structure of H. elisae. A nested approach sensu Mairal et al. (2015) (connecting the evolutionary rates of two datasets of different taxonomic coverage) was used to obtain one approximation to a time-calibrated phylogenetic tree based on external Clitellata fossils and a wide molecular dataset. Our results indicate that limited active dispersal ability and ecological or biotic barriers could explain the isolation of the different cryptic lineages, which never co-occur. Rare events of long distance dispersal through hydrochory appear as one of the possible causes of range expansion. Copyright © 2017 Elsevier Inc. All rights reserved.