Paraxial ray solution for liquid-filled variable focus lenses
NASA Astrophysics Data System (ADS)
Wang, Lihui; Oku, Hiromasa; Ishikawa, Masatoshi
2017-12-01
We propose a general solution for determining the cardinal points and effective focal length of a liquid-filled variable focus lens to aid in understanding the dynamic behavior of the lens when the focal length is changed. A prototype of a variable focus lens was fabricated and used to validate the solution. A simplified solution was also presented that can be used to quickly and conveniently calculate the performance of the lens. We expect that the proposed solutions will improve the design of optical systems that contain variable focus lenses, such as machine vision systems with zoom and focus functions.
Intraocular lens based on double-liquid variable-focus lens.
Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2014-01-10
In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.
Electrowetting-Based Variable-Focus Lens for Miniature Systems
NASA Astrophysics Data System (ADS)
Hendriks, B. H. W.; Kuiper, S.; van As, M. A. J.; et al.
The meniscus between two immiscible liquids of different refractive indices can be used as a lens. A change in curvature of this meniscus by electrostatic control of the solid/liquid interfacial tension leads to a change in focal distance. It is demonstrated that two liquids in a tube form a self-centred variable-focus lens. The optical properties of this lens were investigated experimentally. We designed and constructed a miniature camera module based on this variable lens suitable for mobile applications. Furthermore, the liquid lens was applied in a Blu-ray Disc optical recording system to enable dual layer disc reading/writing.
Optical phase conjugation assisted scattering lens: variable focusing and 3D patterning
Ryu, Jihee; Jang, Mooseok; Eom, Tae Joong; Yang, Changhuei; Chung, Euiheon
2016-01-01
Variable light focusing is the ability to flexibly select the focal distance of a lens. This feature presents technical challenges, but is significant for optical interrogation of three-dimensional objects. Numerous lens designs have been proposed to provide flexible light focusing, including zoom, fluid, and liquid-crystal lenses. Although these lenses are useful for macroscale applications, they have limited utility in micron-scale applications due to restricted modulation range and exacting requirements for fabrication and control. Here, we present a holographic focusing method that enables variable light focusing without any physical modification to the lens element. In this method, a scattering layer couples low-angle (transverse wave vector) components into a full angular spectrum, and a digital optical phase conjugation (DOPC) system characterizes and plays back the wavefront that focuses through the scattering layer. We demonstrate micron-scale light focusing and patterning over a wide range of focal distances of 22–51 mm. The interferometric nature of the focusing scheme also enables an aberration-free scattering lens. The proposed method provides a unique variable focusing capability for imaging thick specimens or selective photoactivation of neuronal networks. PMID:27049442
NASA Astrophysics Data System (ADS)
Wang, Xuan-Yin; Du, Jia-Wei; Zhu, Shi-Qiang
2017-09-01
A bionic variable-focus lens with symmetrical layered structure was designed to mimic the crystalline lens. An optical imaging system based on this lens and with a symmetrical structure that mimics the human eye structure was proposed. The refractive index of the bionic variable-focus lens increases from outside to inside. The two PDMS lenses with a certain thickness were designed to improve the optical performance of the optical imaging system and minimise the gravity effect of liquid. The paper presents the overall structure of the optical imaging system and the detailed description of the bionic variable-focus lens. By pumping liquid in or out of the cavity, the surface curvatures of the rear PDMS lens were varied, resulting in a change in the focal length. The focal length range of the optical imaging system was 20.71-24.87 mm. The optical performance of the optical imaging system was evaluated by imaging experiments and analysed by ray tracing simulations. On the basis of test and simulation results, the optical performance of the system was quite satisfactory. Off-axis aberrations were well corrected, and the image quality was greatly improved.
Liquid Lens module with wide field-of-view and variable focal length
NASA Astrophysics Data System (ADS)
Seo, Sang Won; Han, Seungoh; Seo, Jun Ho; Choi, Woo Bum; Sung, Man Young
2010-12-01
A novel wide angle and variable-focus imaging module based on a miniaturized liquid lens is presented for capsule endoscopy applications. For these applications, it is desirable to have features such as a wide field of view (FOV), variable focus, small size, and low power consumption, thereby taking full advantage of the miniaturized liquid lens. The proposed imaging module has three aspheric plastic lenses for a wide FOV, and one liquid lens that can change the focal length by as much as 24.5 cm with a bias voltage difference of 23 Vrms for variable focusing. The assembled lens module has an overall length of 8.4 mm and a FOV of 120.5°. The realized imaging module including the proposed lenses is small enough to be inserted into a capsule endoscope, and it is expected to improve the diagnostic capability of capsule endoscopes.
NASA Astrophysics Data System (ADS)
Zeng, Zhi; Peng, Runling; He, Mei
2017-02-01
The double-liquid variable-focus lens based on the electrowetting has the characteristics of small size, light weight, fast response, and low price and so on. In this paper, double-liquid variable-focus lens's Principle and structure are introduced. The reasons for the existence and improvement of contact angle hysteresis are given according improved Young's equation. At last, 1-Bromododecane with silicone oil are mixed to get oil liquid with different viscosity and proportion liquid as insulating liquid. External voltages are applied to these three liquid lens and focal lengths of the lenses versus applied voltage are investigated. Experiments show that, the decreasing of oil liquid viscosity can reduce focal length hysteresis.
Variable focus photographic lens without mechanical movements
NASA Astrophysics Data System (ADS)
Chen, Jiabi; Peng, Runling; Zhuang, Songlin
2007-09-01
A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. And detailed calculations and simulation examples are presented to predict how two liquid lenses are related to meet the basic requirements of zoom lenses.
Electrowetting based infrared lens using ionic liquids
NASA Astrophysics Data System (ADS)
Hu, Xiaodong; Zhang, Shiguo; Liu, Yu; Qu, Chao; Lu, Liujin; Ma, Xiangyuan; Zhang, Xiaoping; Deng, Youquan
2011-11-01
We demonstrated an infrared variable focus ionic liquids lens using electrowetting, which could overcome the problems caused by use of water, e.g., evaporation and poor thermostability, while keeping good optical transparency in visible light and near-infrared region. Besides, the type of lens (convex or concave) could be tuned by applied voltage or refractive index of ILs used, and the transmittance was measured to exceed 90% over the spectrum of visible light and near-infrared. We believe this infrared variable focus ionic liquids lens has a great application prospect in both visible light and infrared image systems.
Ultrasound liquid crystal lens
NASA Astrophysics Data System (ADS)
Shimizu, Yuki; Koyama, Daisuke; Fukui, Marina; Emoto, Akira; Nakamura, Kentaro; Matsukawa, Mami
2018-04-01
A variable-focus lens using a combination of liquid crystals and ultrasound is discussed. The lens uses a technique based on ultrasound vibration to control the molecular orientation of the liquid crystal. The lens structure is simple, with no mechanical moving parts and no transparent electrodes, which is helpful for device downsizing; the structure consists of a liquid crystal layer sandwiched between two glass substrates with a piezoelectric ring. The tens-of-kHz ultrasonic resonance flexural vibration used to excite the lens generates an acoustic radiation force on the liquid crystal layer to induce changes in the molecular orientation of the liquid crystal. The orientations of the liquid crystal molecules and the optical characteristics of the lens were investigated under ultrasound excitation. Clear optical images were observed through the lens, and the focal point could be controlled using the input voltage to the piezoelectric ring to give the lens its variable-focus action.
Tunable two-dimensional liquid gradient refractive index (L-GRIN) lens for variable light focusing.
Huang, Hua; Mao, Xiaole; Lin, Sz-Chin Steven; Kiraly, Brian; Huang, Yiping; Huang, Tony Jun
2010-09-21
We report a two-dimensional (2D) tunable liquid gradient refractive index (L-GRIN) lens for variable focusing of light in the out-of-plane direction. This lens focuses a light beam through a liquid medium with a 2D hyperbolic secant (HS) refractive index gradient. The refractive index gradient is established in a microfluidic chamber through the diffusion between two fluids with different refractive indices, i.e. CaCl(2) solution and deionized (DI) water. The 2D HS refractive index profile and subsequently the focal length of the L-GRIN lens can be tuned by changing the ratio of the flow rates of the CaCl(2) solution and DI water. The focusing effect is experimentally characterized through side-view and top-view image analysis, and the experimental data match well with the results from ray-tracing optical simulations. Advantages of the 2D L-GRIN lens include simple device fabrication procedure, low fluid consumption rate, convenient lens-tuning mechanism, and compatibility with existing microfluidic devices. We expect that with further optimizations, this 2D L-GRIN lens can be used in many optics-based lab-on-a-chip applications.
Wong, W; Sivak, J G; Moran, K L
2003-01-01
This study determines the relative ocular lens irritancy of 16 common partially transparent or non-transparent consumer hygiene products. The irritancy was found by measuring the changes in the sharpness of focus [referred to as the back vertex distance (BVD) variability] of the cultured bovine lens using a scanning laser In Vitro Assay System. This method consists of a laser beam that scans across the lens, and a computer, which then analyses the average focal length (mm), the BVD variability (mm), and the intensity of the beam transmitted. Lenses were exposed to the 16 hygiene products and the lens' focusing ability was monitored over 192 h. The products are semi-solids or solids (e.g. gels, lotions, shampoos). They are categorized into six groups: shampoos, body washes, lotions, toothpastes, deodorant, and anti-perspirant. Damage (measured by > 1 mm BVD variability) occurred slower for the shampoos, especially in the case of baby shampoo. The results indicate that shampoos exhibit the lowest level of ocular lens toxicity (irritability) while the deodorant is the most damaging.
Variable-focus liquid lens for miniature cameras
NASA Astrophysics Data System (ADS)
Kuiper, S.; Hendriks, B. H. W.
2004-08-01
The meniscus between two immiscible liquids can be used as an optical lens. A change in curvature of this meniscus by electrowetting leads to a change in focal distance. It is demonstrated that two liquids in a tube form a self-centered lens with a high optical quality. The motion of the lens during a focusing action was studied by observation through the transparent tube wall. Finally, a miniature achromatic camera module was designed and constructed based on this adjustable lens, showing that it is excellently suited for use in portable applications.
Small form-factor VGA camera with variable focus by liquid lens
NASA Astrophysics Data System (ADS)
Oikarinen, Kari A.; Aikio, Mika
2010-05-01
We present the design of a 24 mm long variable focus lens for 1/4" sensor. The chosen CMOS color sensor has VGA (640×480) resolution and 5.6 μm pixel size. The lens utilizes one Varioptic Arctic 320 liquid lens that has a voltage-controllable focal length due to the electrowetting effect. There are no mechanical moving parts. The principle of operation of the liquid lens is explained briefly. We discuss designing optical systems with this type of lens. This includes a modeling approach that allows entering a voltage value to modify the configuration of the liquid lens. The presented design consists only of spherical glass surfaces. The choice to use spherical surfaces was made in order to decrease the costs of manufacturing and provide more predictable performance by the better established method. Fabrication tolerances are compensated by the adjustability of the liquid lens, further increasing the feasibility of manufacturing. The lens is manufactured and assembled into a demonstrator camera. It has an f-number of 2.5 and 40 degree full field of view. The effective focal length varies around 6 millimeters as the liquid lens is adjusted. In simulations we have achieved a focus distance controllable between 20 millimeters and infinity. The design differs from previous approaches by having the aperture stop in the middle of the system instead of in front.
Tests and evaluation of a variable focus liquid lens for curvature wavefront sensors in astronomy.
Fuentes-Fernández, Jorge; Cuevas, Salvador; Álvarez-Nuñez, Luis C; Watson, Alan
2013-10-20
Curvature wavefront sensors (WFSs), which obtain the wavefront aberrations from two defocused intensity images at each side of the pupil plane, have shown to be highly efficient for astronomical applications. We propose here an alternative defocusing mechanism for curvature sensors, based on an electrowetting-based variable focus liquid lens. Typically, the sampling rates of a WFS for active optics are of the order of 0.01 Hz, and the focus modulation can be done by simply moving the detector back and forth. On the other hand, adaptive optics may require speeds of up to several hundred hertz, and the modulation is then done by using a fast vibrating membrane mirror. We believe variable focus liquid lenses may be able to perform this focus modulation, reducing the overall size of the system and without the need of extra moving parts. We have done a full characterization of the Varioptic Arctic 416 liquid lens, and we have evaluated its potential performance in different curvature configurations.
Biomimetic small scale variable focal length lens unit using synthetic elastomer actuators
NASA Astrophysics Data System (ADS)
Kim, Baek-chul; Chung, Jinah; Lee, Y.; Nam, Jae-Do; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, J. C.
2011-04-01
Having a combination of a gel-like soft lens, ligaments, and the Ciliary muscles, the human eyes are effectively working for various focal lengths without a complicated group of lens. The simple and compact but effective optical system should deserve numerous attentions from various technical field especially portable information technology device industry. Noting the limited physical space of those deivces, demanding shock durability, and massive volume productivity, the present paper proposes a biomimetic optical lens unit that is organized with a circular silicone lens and an annular dielectric polymer actuator. Unlike the traditional optical lens mechanism that normally acquires a focus by changing its focal distance with moving lens or focal plane. the proposed optical system changes its lens thickness using a annulary connected polymer actuator in order to get image focuses. The proposed biomimetic lens system ensures high shock durability, compact physical dimensions, fast actuations, simple manufacturing process, and low production cost.
NASA Technical Reports Server (NTRS)
Chutjian, A.
1979-01-01
Geometries and focal properties are given for two types of electron-lens system commonly needed in electron scattering. One is an electron gun that focuses electrons from a thermionic emitter onto a fixed point (target) over a wide range of final energies. The other is an electron analyzer system that focuses scattered electrons of variable energy onto a fixed position (e.g., the entrance plane of an analyzer) at fixed energy with a zero final beam angle. Analyzer-system focusing properties are given for superelastically, elastically, and inelastically scattered electrons. Computer calculations incorporating recent accurate tube-lens focal properties are used to compute lens voltages, locations and diameters of all pupils and windows, filling factors, and asymptotic rays throughout each lens system. Focus voltages as a function of electron energy and energy change are given, and limits of operation of each system discussed. Both lens systems have been in routine use for several years, and good agreement has been consistently found between calculated and operating lens voltages.
Compact touchless fingerprint reader based on digital variable-focus liquid lens
NASA Astrophysics Data System (ADS)
Tsai, C. W.; Wang, P. J.; Yeh, J. A.
2014-09-01
Identity certification in the cyberworld has always been troublesome if critical information and financial transaction must be processed. Biometric identification is the most effective measure to circumvent the identity issues in mobile devices. Due to bulky and pricy optical design, conventional optical fingerprint readers have been discarded for mobile applications. In this paper, a digital variable-focus liquid lens was adopted for capture of a floating finger via fast focusplane scanning. Only putting a finger in front of a camera could fulfill the fingerprint ID process. This prototyped fingerprint reader scans multiple focal planes from 30 mm to 15 mm in 0.2 second. Through multiple images at various focuses, one of the images is chosen for extraction of fingerprint minutiae used for identity certification. In the optical design, a digital liquid lens atop a webcam with a fixed-focus lens module is to fast-scan a floating finger at preset focus planes. The distance, rolling angle and pitching angle of the finger are stored for crucial parameters during the match process of fingerprint minutiae. This innovative compact touchless fingerprint reader could be packed into a minute size of 9.8*9.8*5 (mm) after the optical design and multiple focus-plane scan function are optimized.
Theoretical analysis for double-liquid variable focus lens
NASA Astrophysics Data System (ADS)
Peng, Runling; Chen, Jiabi; Zhuang, Songlin
2007-09-01
In this paper, various structures for double-liquid variable focus lens are introduced. And based on an energy minimization method, explicit calculations and detailed analyses upon an extended Young-type equation are given for double-liquid lenses with cylindrical electrode. Such an equation is especially applicable to liquid-liquid-solid tri-phase systems. It is a little different from the traditional Young equation that was derived according to vapor-liquid-solid triphase systems. The electrowetting effect caused by an external voltage changes the interface shape between two liquids as well as the focal length of the lens. Based on the extended Young-type equation, the relationship between the focal length and the external voltage can also be derived. Corresponding equations and simulation results are presented.
Design of a zoom lens without motorized optical elements
NASA Astrophysics Data System (ADS)
Peng, Runling; Chen, Jiabi; Zhu, Cheng; Zhuang, Songlin
2007-05-01
A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. Detailed calculations and simulation examples are presented to show that this zoom lens system appears viable as the next-generation zoom lens.
Design of a zoom lens without motorized optical elements.
Peng, Runling; Chen, Jiabi; Zhu, Cheng; Zhuang, Songlin
2007-05-28
A novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two double-liquid variable-focus lenses. The liquid lenses, made out of two immiscible liquids, are based on the principle of electrowetting: an effect controlling the wetting properties of a liquid on a solid by modifying the applied voltage at the solid-liquid interface. The structure and principle of the lens system are introduced in this paper. Detailed calculations and simulation examples are presented to show that this zoom lens system appears viable as the next-generation zoom lens.
Measurement of the M² beam propagation factor using a focus-tunable liquid lens.
Niederriter, Robert D; Gopinath, Juliet T; Siemens, Mark E
2013-03-10
We demonstrate motion-free beam quality M² measurements of stigmatic, simple astigmatic, and general astigmatic (twisted) beams using only a focus-tunable liquid lens and a CCD camera. We extend the variable-focus technique to the characterization of general astigmatic beams by measuring the 10 second-order moments of the power density distribution for the twisted beam produced by passage through multimode optical fiber. Our method measures the same M² values as the traditional variable-distance method for a wide range of laser beam sources, including nearly TEM(00) (M²≈1) and general astigmatic multimode beams (M²≈8). The method is simple and compact, with no moving parts or complex apparatus and measurement precision comparable to the standard variable-distance method.
Temperature compensation analysis of liquid lens for variable-focus control
NASA Astrophysics Data System (ADS)
Chen, Shu-Jung; Tai, Tsai-Lin; Shen, Chih-Hsiung
2006-01-01
In this work, a fabrication and temperature compensation analysis and electrowetting for the liquid lenses is proposed. The unique capability of controlling the lens profile during the electrowetting fabrication processes is successfully demonstrated for different ambient temperature environment. For a lens fabricated on a hydrophobic Teflon layer, it is found that when the applied voltage is increased, the focal length increases, and the curvature decreases. One challenge for the liquid lens is operating temperature range. Due to the environment temperature change, the ability of controlling the lens profile is analyzed and measured. The description of change in contact angle corresponding to the variation of ambient temperature is derived. Based on this description, we firstly derive the control of voltage vs. temperature for a fixed dioptric power. The control of lens during a focusing action was studied by observation of the image formed by the light through the transparent bottom of ITO glass. Under several conditions of ambient temperature change, capability of controlling the lens profile for a fixed focus is successfully demonstrated by experiments.
Focal length hysteresis of a double-liquid lens based on electrowetting
NASA Astrophysics Data System (ADS)
Peng, Runling; Wang, Dazhen; Hu, Zhiwei; Chen, Jiabi; Zhuang, Songlin
2013-02-01
In this paper, an extended Young equation especially suited for an ideal cylindrical double-liquid variable-focus lens is derived by means of an energy minimization method. Based on the extended Young equation, a kind of focal length hysteresis effect is introduced into the double-liquid variable-focus lens. Such an effect can be explained theoretically by adding a force of friction to the tri-phase contact line. Theoretical analysis shows that the focal length at a particular voltage can be different depending on whether the applied voltage is increasing or decreasing, that is, there is a focal length hysteresis effect. Moreover, the focal length at a particular voltage must be larger when the voltage is rising than when it is dropping. These conclusions are also verified by experiments.
Electrowetting-driven variable-focus microlens on flexible surfaces
NASA Astrophysics Data System (ADS)
Li, Chenhui; Jiang, Hongrui
2012-06-01
We demonstrate a flexible, electrowetting-driven, variable-focus liquid microlens. The microlens is fabricated using a soft polymer polydimethylsiloxane. The lens can be smoothly wrapped onto a curved surface. A low-temperature fabrication process was developed to reduce the stress on and to avoid any damage to the polymer. The focal length of the microlens varies between -15.0 mm to +28.0 mm, depending on the applied voltage. The resolving power of the microlens is 25.39 line pairs per mm using a 1951 United States Air Force resolution chart. The typical response time of the lens is around 50 ms.
Variable-focus liquid lens for portable applications
NASA Astrophysics Data System (ADS)
Kuiper, Stein; Hendriks, Benno H.; Huijbregts, Laura J.; Hirschberg, A. Mico; Renders, Christel A.; van As, Marco A.
2004-10-01
The meniscus between two immiscible liquids can be used as an optical lens. A change in curvature of this meniscus by electrowetting leads to a change in focal distance. We demonstrate that two liquids in a tube form a self-centered tunable lens of high optical quality. Several properties were studied, such as optical performance, electrical characteristics and dynamic behavior. We designed and constructed a miniature camera module based on this tunable lens and show that it is very well suited for use in portable applications.
Microelectromechanical-System-Based Variable-Focus Liquid Lens for Capsule Endoscopes
NASA Astrophysics Data System (ADS)
Seo, Sang Won; Han, Seungoh; Seo, Jun Ho; Kim, Young Mok; Kang, Moon Sik; Min, Nam Ki; Choi, Woo Beom; Sung, Man Young
2009-05-01
A liquid lens based on the electrowetting phenomenon was designed to be cylindrical to minimize dead area. The lens was fabricated with microelectromechanical-system (MEMS) technology using silicon thin film and wafer bonding processes. A multiple dielectric layer comprising Teflon, silicon nitride, and thermal oxide was formed on the cylinder wall. With a change of 11 Vrms in the applied bias, the lens module, including the fabricated liquid lens, showed a focal length change of approximately 166 mm. A capsule endoscope was assembled, including the lens module, and was successfully used to take images of a pig colon at various focal lengths.
NASA Astrophysics Data System (ADS)
Hwang, Taeseon; Kwon, Hyeok-Yong; Oh, Joon-Suk; Hong, Jung-Pyo; Hong, Seung-Chul; Lee, Youngkwan; Ryeol Choi, Hyouk; Jin Kim, Kwang; Hossain Bhuiya, Mainul; Nam, Jae-Do
2013-07-01
A transparent dielectric elastomer actuator driven by few-layer-graphene (FLG) electrode was experimentally investigated. The electrodes were made of graphene, which was dispersed in N-methyl-pyrrolidone. The transparent actuator was fabricated from developed FLG electrodes. The FLG electrode with its sheet resistance of 0.45 kΩ/sq (80 nm thick) was implemented to mask silicone elastomer. The developed FLG-driven actuator exhibited an optical transparency of over 57% at a wavenumber of 600 nm and produced bending displacement performance ranging from 29 to 946 μm as functions of frequency and voltage. The focus variation was clearly demonstrated under actuation to study its application-feasibility in variable focus lens and various opto-electro-mechanical devices.
Electrowetting-driven variable-focus microlens on flexible surfaces.
Li, Chenhui; Jiang, Hongrui
2012-06-04
We demonstrate a flexible, electrowetting-driven, variable-focus liquid microlens. The microlens is fabricated using a soft polymer polydimethylsiloxane. The lens can be smoothly wrapped onto a curved surface. A low-temperature fabrication process was developed to reduce the stress on and to avoid any damage to the polymer. The focal length of the microlens varies between -15.0 mm to +28.0 mm, depending on the applied voltage. The resolving power of the microlens is 25.39 line pairs per mm using a 1951 United States Air Force resolution chart. The typical response time of the lens is around 50 ms.
Electrowetting-driven variable-focus microlens on flexible surfaces
Li, Chenhui; Jiang, Hongrui
2012-01-01
We demonstrate a flexible, electrowetting-driven, variable-focus liquid microlens. The microlens is fabricated using a soft polymer polydimethylsiloxane. The lens can be smoothly wrapped onto a curved surface. A low-temperature fabrication process was developed to reduce the stress on and to avoid any damage to the polymer. The focal length of the microlens varies between −15.0 mm to +28.0 mm, depending on the applied voltage. The resolving power of the microlens is 25.39 line pairs per mm using a 1951 United States Air Force resolution chart. The typical response time of the lens is around 50 ms. PMID:22904571
Reflectance confocal microscopy of oral epithelial tissue using an electrically tunable lens
NASA Astrophysics Data System (ADS)
Jabbour, Joey M.; Malik, Bilal H.; Cuenca, Rodrigo; Cheng, Shuna; Jo, Javier A.; Cheng, Yi-Shing L.; Wright, John M.; Maitland, Kristen C.
2014-02-01
We present the use of a commercially available electrically tunable lens to achieve axial scanning in a reflectance confocal microscope. Over a 255 μm axial scan range, the lateral and axial resolutions varied from 1-2 μm and 4-14 μm, respectively, dependent on the variable focal length of the tunable lens. Confocal imaging was performed on normal human biopsies from the oral cavity ex vivo. Sub-cellular morphologic features were seen throughout the depth of the epithelium while axially scanning using the focus tunable lens.
Gagnon, Yakir Luc; Wilby, David; Temple, Shelby Eric
2016-09-01
Light rays of different wavelengths are focused at different distances when they pass through a lens (longitudinal chromatic aberration [LCA]). For animals with color vision this can pose a serious problem, because in order to perceive a sharp image the rays must be focused at the shallow plane of the photoreceptor's outer segments in the retina. A variety of fish and tetrapods have been found to possess multifocal lenses, which correct for LCA by assigning concentric zones to correctly focus specific wavelengths. Each zone receives light from a specific beam entrance position (BEP) (the lateral distance between incoming light and the center of the lens). Any occlusion of incoming light at specific BEPs changes the composition of the wavelengths that are correctly focused on the retina. Here, we calculated the effect of lens position relative to the plane of the iris and light entering the eye at oblique angles on how much of the lens was involved in focusing the image on the retina (measured as the availability of BEPs). We used rotational photography of fish eyes and mathematical modeling to quantify the degree of lens occlusion. We found that, at most lens positions and viewing angles, there was a decrease of BEP availability and in some cases complete absence of some BEPs. Given the implications of these effects on image quality, we postulate that three morphological features (aphakic spaces, curvature of the iris, and intraretinal variability in spectral sensitivity) may, in part, be adaptations to mitigate the loss of spectral image quality in the periphery of the eyes of fishes.
Fresnel Lens Solar Concentrator Design Based on Geometric Optics and Blackbody Radiation Equations
NASA Technical Reports Server (NTRS)
Watson, Michael D.; Jayroe, Robert, Jr.
1999-01-01
Fresnel lenses have been used for years as solar concentrators in a variety of applications. Several variables effect the final design of these lenses including: lens diameter, image spot distance from the lens, and bandwidth focused in the image spot. Defining the image spot as the geometrical optics circle of least confusion and applying blackbody radiation equations the spot energy distribution can be determined. These equations are used to design a fresnel lens to produce maximum flux for a given spot size, lens diameter, and image distance. This approach results in significant increases in solar efficiency over traditional single wavelength designs.
Variable-focus side-firing endoscopic device
NASA Astrophysics Data System (ADS)
Lemberg, Vladimir G.; Black, Michael
1996-05-01
Conventional side-firing fiber technology exhibits performance limitations and utilizes expensive single-use only devices which often require multiple fibers for laser prostatectomy. Another limitation of existing side-firing fiber technology is its inability to focus the beam to create incisions for urologic applications such as laser TURP (transurethral resectional prostatectomy), tumor necrosis, lithotripsy, genital warts, and photodynamic therapy. Newly introduced variable-focus side-firing endoscopic device utilizes either one or two lenses and a mirror, onto a single cylinder of molded glass. The laser beam exits the optical fiber, passes through the lens, strikes the cylindrical mirror, and traverses the cylindrical surface. Depending on the design, the laser beam is reflected at the angles ranging from 30 degrees to 120 degrees out of the cylindrical lens. A second lens can be formed onto the side of the cylindrical surface at the beam's exit point. Another advantage of the innovative side-firing device is its capability to provide versatile matching to multiple laser wavelengths from 360 nm to 2.5 microns, and achieve power densities great enough to perform vaporization, incision and coagulation of tissue. Precise focusing of the laser beam results in reduced tissue necrosis of surrounding the treatment area as well as in decreased laser radiation back-scattering. Surgeons can very the focus by adjusting the distance from the tip to the target area. The variable focus side-firing device provides a focused beam at the range of 1.0 to 1.5 mm, for incision. Outside this range, it produces a defocused beam for coagulation.
Remote adjustable focus Raman spectroscopy probe
Schmucker, John E.; Blasi, Raymond J.; Archer, William B.
1999-01-01
A remote adjustable focus Raman spectroscopy probe allows for analyzing Raman scattered light from a point of interest external probe. An environmental barrier including at least one window separates the probe from the point of interest. An optical tube is disposed adjacent to the environmental barrier and includes a long working length compound lens objective next to the window. A beam splitter and a mirror are at the other end. A mechanical means is used to translated the prove body in the X, Y, and Z directions resulting in a variable focus optical apparatus. Laser light is reflected by the beam splitter and directed toward the compound lens objective, then through the window and focused on the point of interest. Raman scattered light is then collected by the compound lens objective and directed through the beam splitter to a mirror. A device for analyzing the light, such as a monochrometer, is coupled to the mirror.
Oscillating fluid lens in coherent retinal projection displays for extending depth of focus
NASA Astrophysics Data System (ADS)
von Waldkirch, extending depth of focus M.; Lukowicz, P.; Troster, G.
2005-09-01
See-through head-mounted displays, which allow to overlay virtual information over the user's real view, suffer normally from a limited depth of focus (DOF). To overcome this problem we discuss in this paper the use of a fast oscillating, variable-focus lens in a retinal projection display. The evaluation is based on a schematic eye model and on the partial coherence simulation tool SPLAT which allows us to calculate the projected retinal images of a text target. Objective image quality criteria demonstrate that the use of an oscillating lens is promising provided that partially coherent illumination light is used. In this case, psychometric measurements reveal that the depth of focus for reading text can be extended by a factor of up to 2.2. For fully coherent and incoherent illumination, however, the retinal images suffer from structural and contrast degradation effects, respectively.
A Novel Variable-Focus Lens for HFGW
NASA Astrophysics Data System (ADS)
Woods, R. Clive
2006-01-01
Li and Torr published calculations claiming to show that gravitational waves (GWs) propagate inside superconductors with a phase velocity reduction (compared to free space) by a factor n ~ 300× and a wavenumber increase by a factor n. This gives major opportunities for designing future GW components able to focus, refract, reflect, and otherwise manipulate gravitational waves for efficient coupling to detectors, transmitters, generators, resonant chambers, and other sensors. To exploit this result, a novel type of HFGW lens design is proposed here using a magnetic field to adjust the focal length in an infinitely-variable manner. Type-II superconductors do not always completely expel large magnetic fields; above their lower critical field they allow vortices of magnetic flux to channel the magnetic field through the material. Within these vortices, the superconductor is magnetically quenched and so behaves as a non-superconductor. Varying the applied magnetic field varies the proportion of material that is quenched. This subsequently affects GW propagation behavior through a type II superconductor. Therefore, using a suitable non-uniform magnetic field, the GW optical path length may be arranged to vary in a technologically useful manner. A GW lens may be designed with focal length dependent upon the applied magnetic field. Such a lens would be invaluable in the design of advanced GW optics since focusing will be achieved electrically with no moving parts; for this reason it would be unparalleled in conventional optics. Since, therefore, variations in n (due to calculation error limits) can be compensated electrically, successful demonstration of this device would confirm the Li and Torr prediction much more easily than directly using a fixed lens structure. The device would also enable fast auto-focusing, zooming, and imaging tomography using electronic servos following development of the necessary HFGW detectors.
Membrane-less variable focus liquid lens with manual actuation
NASA Astrophysics Data System (ADS)
Patra, Roshan; Agarwal, Shivam; Kondaraju, Sasidhar; Bahga, Supreet Singh
2017-04-01
We present a tunable, membrane-less, mechanical-wetting liquid lens that can be actuated manually using a linear actuator such as screw or piston. The operation of the liquid lens is based on deforming the interface separating two immiscible liquids with different refractive indices, while pinning the three-phase contact line at the sharp edge of lens aperture. Our lens design improves upon the existing designs of mechanical-wetting lenses by eliminating the use of complex actuation mechanisms, without compromising on the optical performance. We demonstrate the operation of the liquid lens by tuning its power back and forth from negative to positive by simple rotation of a screw. We also present an analytical description of the focal length of the lens and validate it with detailed experimental measurements. Our experiments show that the focal length of the liquid lens can be tuned repeatably without any adverse effects of hysteresis and gravity.
Adaptive lenses using transparent dielectric elastomer actuators
NASA Astrophysics Data System (ADS)
Shian, Samuel; Diebold, Roger; Clarke, David
2013-03-01
Variable focal lenses, used in a vast number of applications such as endoscope, digital camera, binoculars, information storage, communication, and machine vision, are traditionally constructed as a lens system consisting of solid lenses and actuating mechanisms. However, such lens system is complex, bulky, inefficient, and costly. Each of these shortcomings can be addressed using an adaptive lens that performs as a lens system. In this presentation, we will show how we push the boundary of adaptive lens technology through the use of a transparent electroactive polymer actuator that is integral to the optics. Detail of our concepts and lens construction will be described as well as electromechanical and optical performances. Preliminary data indicate that our adaptive lens prototype is capable of varying its focus by more than 100%, which is higher than that of human eyes. Furthermore, we will show how our approach can be used to achieve certain controls over the lens characteristics such as adaptive aberration and optical axis, which are difficult or impossible to achieve in other adaptive lens configurations.
Electrowetting-actuated zoom lens with spherical-interface liquid lenses.
Peng, Runling; Chen, Jiabi; Zhuang, Songlin
2008-11-01
The interface shape of two immiscible liquids in a conical chamber is discussed. The analytical solution of the differential equation describing the interface shape shows that the interface shape is completely spherical when the density difference of two liquids is zero. On the basis of the spherical-interface shape and an energy-minimization method, explicit calculations and detailed analyses of an extended Young-type equation for the conical double-liquid lens are given. Finally, a novel design of a zoom lens system without motorized movements is proposed. The lens system consists of a fixed lens and two conical double-liquid variable-focus lenses. The structure and principle of the lens system are introduced in this paper. Taking finite objects as example, detailed calculations and simulation examples are presented to predict how two liquid lenses are related to meet the basic requirements of zoom lenses.
Fresnel Lens Solar Concentrator Design Based on Geometric Optics and Blackbody Radiation Equations
NASA Technical Reports Server (NTRS)
Watson, Michael D.; Jayroe, Robert
1998-01-01
Fresnel lenses have been used for years as solar concentrators in a variety of applications. Several variables effect the final design of these lenses including: lens diameter, image spot distance from the lens, and bandwidth focused in the image spot. Defining the image spot as the geometrical optics circle of least confusion, a set of design equations has been derived to define the groove angles for each groove on the lens. These equations allow the distribution of light by wavelength within the image spot to be calculated. Combining these equations with the blackbody radiation equations, energy distribution, power, and flux within the image spot can be calculated. In addition, equations have been derived to design a lens to produce maximum flux in a given spot size. Using these equations, a lens may be designed to optimize the spot energy concentration for given energy source.
Modeling of a Variable Focal Length Flat Lens Using Left Handed Metamaterials
NASA Technical Reports Server (NTRS)
Reinert, Jason
2004-01-01
Left Handed Metamaterials (LHM) were originally purposed by Victor Veselago in1968. These substances would allow a flat structure to focus electromagnetic (EM) waves because they have a negative index of refraction. A similar structure made from conventional materials, those with a positive index of refraction, would disperse the waves. But until recently, these structures have been purely theoretical because substances with both a negative permittivity and negative permeability, material properties necessary for a negative index of refraction, do not naturally exist, Recent developments have produced a structure composed of an array of thin wires and split ring resonators that shows a negative index of refraction. area smaller than a square wavelength. How small the area is can be determined by how perfectly the lens is polished and how pure the substance is that composes the lens. These lenses must also be curved for focusing to occur. The focal length is determined by the curvature of the lens and the material. On the other hand, a flat structure made from LHM would focus light because of the effect of a negative index of refraction in Snell s law. The focal length could also be varied by simply adjusting the distance of the lens from the source of radiation. This could create many devices that are adjustable to different situations in fields such as biomedical imaging and communication. the software package XFDTD which solves Maxwell s equations in the frequency domain as well as the time domain. The program used Drude models of materials to simulate the effect of negative permittivity and negative permeability. Because of this, a LHM can be simulated as a solid block of material instead of an array of wires and split ring resonators. After a flat lens is formed, I am to examine the focusing effect of the lens and determine if a higher resolution flat lens can be developed. Traditional lenses made from conventional materials cannot focus an EM wave onto an My goal was to model LHMs and create a flat lens from them. This was to be done using
Sheikh, Mumtaz; Riza, Nabeel A
2010-06-01
To the best of our knowledge, we propose the first motion-free laser beam propagation analyzer with a hybrid design using a digital micromirror device (DMD) and a liquid electronically controlled variable focus lens (ECVFL). Unlike prior analyzers that require profiling the beam at multiple locations along the light propagation axis, the proposed analyzer profiles the beam at the same plane for multiple values of the ECVFL focal length, thus eliminating beam profiler assembly motion. In addition to measuring standard Gaussian beam parameters, the analyzer can also be used to measure the M(2) beam propagation parameter of a multimode beam. Proof-of-concept beam parameter measurements with the proposed analyzer are successfully conducted for a 633 nm laser beam. Given the all-digital nature of the DMD-based profiling and all-analog motion-free nature of the ECVFL beam focus control, the proposed analyzer versus prior art promises better repeatability, speed, and reliability.
Applications of variable focus liquid lenses for curvature wave-front sensors in astronomy
NASA Astrophysics Data System (ADS)
Fuentes-Fernández, J.; Cuevas, S.; Alvarez-Nuñez, L. C.; Watson, A. M.
2014-08-01
Curvature wavefront sensors obtain the wave-front aberrations from two defocused intensity images at each side of the pupil plane. Typically, when high modulation speeds are required, as it is the case with Adaptive Optics, that defocusing is done with a fast vibrating membrane mirror. We propose an alternative defocusing mechanism based on an electrowetting variable focus liquid lens. The use of such lenses may perform the required focus modulation without the need of extra moving parts, reducing the overall size of the system.
Transformation optics with windows
NASA Astrophysics Data System (ADS)
Oxburgh, Stephen; White, Chris D.; Antoniou, Georgios; Orife, Ejovbokoghene; Courtial, Johannes
2014-09-01
Identity certification in the cyberworld has always been troublesome if critical information and financial transaction must be processed. Biometric identification is the most effective measure to circumvent the identity issues in mobile devices. Due to bulky and pricy optical design, conventional optical fingerprint readers have been discarded for mobile applications. In this paper, a digital variable-focus liquid lens was adopted for capture of a floating finger via fast focusplane scanning. Only putting a finger in front of a camera could fulfill the fingerprint ID process. This prototyped fingerprint reader scans multiple focal planes from 30 mm to 15 mm in 0.2 second. Through multiple images at various focuses, one of the images is chosen for extraction of fingerprint minutiae used for identity certification. In the optical design, a digital liquid lens atop a webcam with a fixed-focus lens module is to fast-scan a floating finger at preset focus planes. The distance, rolling angle and pitching angle of the finger are stored for crucial parameters during the match process of fingerprint minutiae. This innovative compact touchless fingerprint reader could be packed into a minute size of 9.8*9.8*5 (mm) after the optical design and multiple focus-plane scan function are optimized.
Polydimethylsiloxane as dielectric and hydrophobic material in electro-wetting liquid lens
NASA Astrophysics Data System (ADS)
Wang, Liang; Duan, Junping; Zhang, Binzhen; Wang, Wanjun
2016-10-01
An electro-wetting-based variable-focus liquid lens with a spin coated polydimethylsiloxane (PDMS) layer is presented. The PDMS layer acts as both insulation and hydrophobic material of the liquid lens. By changing the applied voltage between the two electrodes, the radius of the water-oil contact curved surface is adjusted to realize the zoom function. In preparation process, at first, the liquid lens is divided into two parts, the PDMS substrate and the cavity, and then two parts of liquid lens are bonding together after surface treatment. After liquid injection and sealing cavity, the whole process was accomplished. The zooming performance of lens is tested, and COMSOL is used to analyze the shape of the water-oil contact curved surface at different voltages, the results shows that with the applied voltage changing from 0V to 120V, the height of meniscus vertex reduced from 2.41mm to 1.67mm, and the focal length changes from -14.3mm to infinity first, and then to 27.1mm.
Electrowetting-based liquid lenses for endoscopy
NASA Astrophysics Data System (ADS)
Kuiper, S.
2011-03-01
In endoscopy there is a need for cameras with adjustable focus. In flexible and capsule endoscopes conventional focus systems are not suitable, because of restrictions in diameter and lens displacement range. In this paper it is shown that electrowetting-based variable-focus liquid lenses can provide a solution. A theoretical comparison is made between displacing and deforming lenses, and a demonstrator was built to prove the optical feasibility of focusing with liquid lenses in endoscopes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barton, Ian M.; Dixit, Sham N.; Summers, Leslie J.
2000-01-01
A diffractive Alvarez lens is demonstrated that consists of two separate phase plates, each having complementary 16-level surface-relief profiles that contain cubic phase delays. Translation of these two components in the plane of the phase plates is shown to produce a variable astigmatic focus. Both spherical and cylindrical phase profiles are demonstrated with good accuracy, and the discrete surface-relief features are shown to cause less than {lambda}/10 wave-front aberration in the transmitted wave front over a 40 mmx80 mm region. (c) 2000 Optical Society of America.
NASA Technical Reports Server (NTRS)
Picco, C. E.; Shavers, M. R.; Victor, J. M.; Duron, J. L.; Bowers, W. h.; Gillis, D. B.; VanBaalen, M.
2009-01-01
LIDAR systems that maintain a constant beam spot size on a retroreflector in order to increase the accuracy of bearing and ranging data must use a software controlled variable position lens. These systems periodically update the estimated range and set the position of the focusing lens accordingly. In order to precisely calculate the r NOHD for such a system, the software method for setting the variable position lens and gaussian laser propagation can be used to calculate the irradiance at any point given the range estimation. NASA s Space Shuttle LIDAR, called the Trajectory Control Sensor (TCS), uses this configuration. Analytical tools were developed using Excel and VBA to determine the radiant energy to the International Space Station (ISS) crewmembers eyes while viewing the shuttle on approach and departure. Various viewing scenarios are considered including the use of through-the-lens imaging optics and the window transmissivity at the TCS wavelength. The methodology incorporates the TCS system control logic, gaussian laser propagation, potential failure mode end states, and guidance from American National Standard for the Safe Use of Lasers (ANSI Z136.1-2007). This approach can be adapted for laser safety analyses of similar LIDAR systems.
Ozbay, Baris N.; Losacco, Justin T.; Cormack, Robert; Weir, Richard; Bright, Victor M.; Gopinath, Juliet T.; Restrepo, Diego; Gibson, Emily A.
2015-01-01
We report a miniature, lightweight fiber-coupled confocal fluorescence microscope that incorporates an electrowetting variable focus lens to provide axial scanning for full three-dimensional (3D) imaging. Lateral scanning is accomplished by coupling our device to a laser-scanning confocal microscope through a coherent imaging fiber-bundle. The optical components of the device are combined in a custom 3D-printed adapter with an assembled weight of <2 g that can be mounted onto the head of a mouse. Confocal sectioning provides an axial resolution of ~12 µm and an axial scan range of ~80 µm. The lateral field-of-view is 300 µm, and the lateral resolution is 1.8 µm. We determined these parameters by imaging fixed sections of mouse neuronal tissue labeled with green fluorescent protein (GFP) and fluorescent bead samples in agarose gel. To demonstrate viability for imaging intact tissue, we resolved multiple optical sections of ex vivo mouse olfactory nerve fibers expressing yellow fluorescent protein (YFP). PMID:26030555
Ultra-high-speed variable focus optics for novel applications in advanced imaging
NASA Astrophysics Data System (ADS)
Kang, S.; Dotsenko, E.; Amrhein, D.; Theriault, C.; Arnold, C. B.
2018-02-01
With the advancement of ultra-fast manufacturing technologies, high speed imaging with high 3D resolution has become increasingly important. Here we show the use of an ultra-high-speed variable focus optical element, the TAG Lens, to enable new ways to acquire 3D information from an object. The TAG Lens uses sound to adjust the index of refraction profile in a liquid and thereby can achieve focal scanning rates greater than 100 kHz. When combined with a high-speed pulsed LED and a high-speed camera, we can exploit this phenomenon to achieve high-resolution imaging through large depths. By combining the image acquisition with digital image processing, we can extract relevant parameters such as tilt and angle information from objects in the image. Due to the high speeds at which images can be collected and processed, we believe this technique can be used as an efficient method of industrial inspection and metrology for high throughput applications.
Miniature objective lens with variable focus for confocal endomicroscopy
Kim, Minkyu; Kang, DongKyun; Wu, Tao; Tabatabaei, Nima; Carruth, Robert W.; Martinez, Ramses V; Whitesides, George M.; Nakajima, Yoshikazu; Tearney, Guillermo J.
2014-01-01
Spectrally encoded confocal microscopy (SECM) is a reflectance confocal microscopy technology that can rapidly image large areas of luminal organs at microscopic resolution. One of the main challenges for large-area SECM imaging in vivo is maintaining the same imaging depth within the tissue when patient motion and tissue surface irregularity are present. In this paper, we report the development of a miniature vari-focal objective lens that can be used in an SECM endoscopic probe to conduct adaptive focusing and to maintain the same imaging depth during in vivo imaging. The vari-focal objective lens is composed of an aspheric singlet with an NA of 0.5, a miniature water chamber, and a thin elastic membrane. The water volume within the chamber was changed to control curvature of the elastic membrane, which subsequently altered the position of the SECM focus. The vari-focal objective lens has a diameter of 5 mm and thickness of 4 mm. A vari-focal range of 240 μm was achieved while maintaining lateral resolution better than 2.6 μm and axial resolution better than 26 μm. Volumetric SECM images of swine esophageal tissues were obtained over the vari-focal range of 260 μm. SECM images clearly visualized cellular features of the swine esophagus at all focal depths, including basal cell nuclei, papillae, and lamina propria. PMID:25574443
Mechanical Design Report DARPA BOSS Program
2008-03-21
for system mass and length; tolerances for lens spacing, tilt , and diameter; tolerances for lens to lens concentricity and lens perimeter to focus...binding when the lens is compressed, which could otherwise introduce tilt in the lens surface. Part b is the solid stop against which lens 3 (part...Fixed lens angular ( tilt ) accuracy ±3° Lens concentricity ±0.150mm Temperature range 10-45°C Minimum BFL adjustment ±1.5 mm from design focus
Computerized method and system for designing an aerodynamic focusing lens stack
Gard, Eric [San Francisco, CA; Riot, Vincent [Oakland, CA; Coffee, Keith [Diablo Grande, CA; Woods, Bruce [Livermore, CA; Tobias, Herbert [Kensington, CA; Birch, Jim [Albany, CA; Weisgraber, Todd [Brentwood, CA
2011-11-22
A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.
The Alvarez and Lohmann refractive lenses revisited.
Barbero, Sergio
2009-05-25
Alvarez and Lohmann lenses are variable focus optical devices based on lateral shifts of two lenses with cubic-type surfaces. I analyzed the optical performance of these types of lenses computing the first order optical properties (applying wavefront refraction and propagation) without the restriction of the thin lens approximation, and the spot diagram using a ray tracing algorithm. I proposed an analytic and numerical method to select the most optimum coefficients and the specific configuration of these lenses. The results show that Lohmann composite lens is slightly superior to Alvarez one because the overall thickness and optical aberrations are smaller.
ERIC Educational Resources Information Center
Hogrebe, Mark C.; Tate, William F., IV
2012-01-01
In this chapter, "geospatial" refers to geographic space that includes location, distance, and the relative position of things on the earth's surface. Geospatial perspective calls for the addition of a geographic lens that focuses on place and space as important contextual variables. A geospatial view increases one's understanding of…
The effect of defocusing on spot diameter when ablate the silicon surface by femtosecond laser
NASA Astrophysics Data System (ADS)
Luo, Xinkai; Li, Wei; Wu, Tengfei; Wang, Yu; Zhu, Zhenyu
2018-02-01
Femtosecond laser has been demonstrated to be a prominent tool to manufacture micro scale structure. In the processing, the focusing lens is usually used as the concentrated tool to assemble the original beam to the tiny spot to provide enough energy for ablation. What is more, different focal length means the diverse scale of the focused spot. In common use, various sizes of the spot are required to adjust to the multifarious profiles and substituting the focus lens is the general method. There is no doubt that changing the lens is a fussy job and frequent replacing the lens may cause the lack of stability. In this paper, we report the defocus of the lens to modify the scale of the spot and it is proved to be an effective way to vary the diameter of the focused spot without changing the focus lens.
ERIC Educational Resources Information Center
Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.
2008-01-01
We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.
Generalized Alvarez lens for correction of laser aberrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaFortune, K N
2004-12-02
The Alvarez lens (US Patent No. 3,305,294 [1]) is a compact aberration corrector. The original design emphasized in the patent consists of a pair of adjacent optical elements that provide a variable focus. A lens system with a variable effective focal length is nothing new. Such systems are widely used in cameras, for example. It is the compactness and simplicity of operation that is the key advantage of the Alvarez lens. All of the complexity is folded into the design and fabrication of the optical elements. As mentioned in the Alvarez patent [1] and elaborated upon in Palusinski et al.more » [2], if one is willing to fold even more complexity into the optical elements, it is possible to correct higher-order aberrations as well. There is no theoretical limit to the number or degree of wavefront distortions that can be corrected. The only limitation is that there must be a fixed relative magnitude of the aberrations. Independent correction of each component of the higher-order aberrations can not be performed without additional elements and degrees of freedom [3]. Under some circumstances, coupling may be observed between different aberrations. This can be mitigated with the appropriate choice of design parameters. New methods are available today that increase the practicality of making higher-order aberration correctors [4,5,6].« less
Portable biochip scanner device
Perov, Alexander; Sharonov, Alexei; Mirzabekov, Andrei D.
2002-01-01
A portable biochip scanner device used to detect and acquire fluorescence signal data from biological microchips (biochips) is provided. The portable biochip scanner device employs a laser for emitting an excitation beam. An optical fiber delivers the laser beam to a portable biochip scanner. A lens collimates the laser beam, the collimated laser beam is deflected by a dichroic mirror and focused by an objective lens onto a biochip. The fluorescence light from the biochip is collected and collimated by the objective lens. The fluorescence light is delivered to a photomultiplier tube (PMT) via an emission filter and a focusing lens. The focusing lens focuses the fluorescence light into a pinhole. A signal output of the PMT is processed and displayed.
Magnetically adjustable intraocular lens.
Matthews, Michael Wayne; Eggleston, Harry Conrad; Pekarek, Steven D; Hilmas, Greg Eugene
2003-11-01
To provide a noninvasive, magnetic adjustment mechanism to the repeatedly and reversibly adjustable, variable-focus intraocular lens (IOL). University of Missouri-Rolla, Rolla, and Eggleston Adjustable Lens, St. Louis, Missouri, USA. Mechanically adjustable IOLs have been fabricated and tested. Samarium and cobalt rare-earth magnets have been incorporated into the poly(methyl methacrylate) (PMMA) optic of these adjustable lenses. The stability of samarium and cobalt in the PMMA matrix was examined with leaching studies. Operational force testing of the magnetic optics with emphasis on the rotational forces of adjustment was done. Prototype optics incorporating rare-earth magnetic inserts were consistently produced. After 32 days in solution, samarium and cobalt concentration reached a maximum of 5 ppm. Operational force measurements indicate that successful adjustments of this lens can be made using external magnetic fields with rotational torques in excess of 0.6 ounce inch produced. Actual lenses were remotely adjusted using magnetic fields. The magnetically adjustable version of this IOL is a viable and promising means of handling the common issues of postoperative refractive errors without the requirement of additional surgery. The repeatedly adjustable mechanism of this lens also holds promise for the developing eyes of pediatric patients and the changing needs of all patients.
NASA Astrophysics Data System (ADS)
Kawamura, Marenori; Sato, Susumu
2018-05-01
The variable range of lens power of a liquid-crystal (LC) lens driven by two voltages is discussed on the basis of calculated and experimental results. The LC lens has two electrodes, which are a circularly hole-patterned electrode and a circular electrode, in addition to a common electrode, and highly resistive transparent films. The variable range of lens power increases with increasing driving voltage applied across the circularly hole-patterned electrode and the common electrode, and with decreasing diameter of highly resistive films. However, the optical-phase retardation profile tends to deviate from a parabolic curve in these cases. As a method to improve the trade-off properties, the highly resistive film is divided into two regions with different diameters, where the sheet resistance of an outer film is larger than that of an inner one. The improved LC lens has a lens power that varies in a wide range, and it exhibits a good parabolic phase retardation profile.
An Atomic Lens Using a Focusing Hollow Beam
NASA Astrophysics Data System (ADS)
Xia, Yong; Yin, Jian-Ping; Wang, Yu-Zhu
2003-05-01
We propose a new method to generate a focused hollow laser beam by using an azimuthally distributed 2pi-phase plate and a convergent thin lens, and calculate the intensity distribution of the focused hollow beam in free propagation space. The relationship between the waist wo of the incident collimated Gaussian beam and the dark spot size of the focused hollow beam at the focal point, and the relationship between the focal length f of the thin lens and the dark spot size are studied respectively. The optical potential of the blue-detuned focused hollow beam for 85Rb atoms is calculated. Our study shows that when the larger waist w of the incident Gaussian beam and the shorter focal length f of the lens are chosen, we can obtain an extremely small dark spot size of the focused hollow beam, which can be used to form an atomic lens with a resolution of several angstroms.
Optical fiber plasmonic lens for near-field focusing fabricated through focused ion beam
NASA Astrophysics Data System (ADS)
Sloyan, Karen; Melkonyan, Henrik; Moreira, Paulo; Dahlem, Marcus S.
2017-02-01
We report on numerical simulations and fabrication of an optical fiber plasmonic lens for near-field focusing applications. The plasmonic lens consists of an Archimedean spiral structure etched through a 100 nm-thick Au layer on the tip of a single-mode SM600 optical fiber operating at a wavelength of 632:8 nm. Three-dimensional finite-difference time-domain computations show that the relative electric field intensity of the focused spot increases 2:1 times when the number of turns increases from 2 to 12. Furthermore, a reduction of the intensity is observed when the initial inner radius is increased. The optimized plasmonic lens focuses light into a spot with a full-width at half-maximum of 182 nm, beyond the diffraction limit. The lens was fabricated by focused ion beam milling, with a 200nm slit width.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Zhou; Tu, Juan; Cheng, Jianchun
An acoustic focusing lens incorporated with periodically aligned subwavelength grooves corrugated on its spherical surface has been developed. It is demonstrated theoretically and experimentally that acoustic focusing achieved by using the lens can suppress the relative side-lobe amplitudes, enhance the focal gain, and minimize the shifting of the focus. Use of the lens coupled with a planar ultrasound transducer can generate an ultrasound beam with enhanced acoustic transmission and collimation effect, which offers the capability of improving the safety, efficiency, and accuracy of targeted surgery implemented by high intensity focused ultrasound.
Tunable-focus lens for adaptive eyeglasses
Hasan, Nazmul; Banerjee, Aishwaryadev; Kim, Hanseup; Mastrangelo, Carlos H.
2017-01-01
We demonstrate the implementation of a compact tunable-focus liquid lens suitable for adaptive eyeglass application. The lens has an aperture diameter of 32 mm, optical power range of 5.6 diopter, and electrical power consumption less than 20 mW. The lens inclusive of its piezoelectric actuation mechanism is 8.4 mm thick and weighs 14.4 gm. The measured lens RMS wavefront aberration error was between 0.73 µm and 0.956 µm. PMID:28158006
Miniaturized unified imaging system using bio-inspired fluidic lens
NASA Astrophysics Data System (ADS)
Tsai, Frank S.; Cho, Sung Hwan; Qiao, Wen; Kim, Nam-Hyong; Lo, Yu-Hwa
2008-08-01
Miniaturized imaging systems have become ubiquitous as they are found in an ever-increasing number of devices, such as cellular phones, personal digital assistants, and web cameras. Until now, the design and fabrication methodology of such systems have not been significantly different from conventional cameras. The only established method to achieve focusing is by varying the lens distance. On the other hand, the variable-shape crystalline lens found in animal eyes offers inspiration for a more natural way of achieving an optical system with high functionality. Learning from the working concepts of the optics in the animal kingdom, we developed bio-inspired fluidic lenses for a miniature universal imager with auto-focusing, macro, and super-macro capabilities. Because of the enormous dynamic range of fluidic lenses, the miniature camera can even function as a microscope. To compensate for the image quality difference between the central vision and peripheral vision and the shape difference between a solid-state image sensor and a curved retina, we adopted a hybrid design consisting of fluidic lenses for tunability and fixed lenses for aberration and color dispersion correction. A design of the world's smallest surgical camera with 3X optical zoom capabilities is also demonstrated using the approach of hybrid lenses.
Focusing a fountain of neutral cesium atoms with an electrostatic lens triplet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalnins, Juris G.; Amini, Jason M.; Gould, Harvey
2005-10-15
An electrostatic lens with three focusing elements in an alternating-gradient configuration is used to focus a fountain of cesium atoms in their ground (strong-field-seeking) state. The lens electrodes are shaped to produce only sextupole plus dipole equipotentials which avoids adding the unnecessary nonlinear forces present in cylindrical lenses. Defocusing between lenses is greatly reduced by having all of the main electric fields point in the same direction and be of nearly equal magnitude. The addition of the third lens gave us better control of the focusing strength in the two transverse planes and allowed focusing of the beam to halfmore » the image size in both planes. The beam envelope was calculated for lens voltages selected to produced specific focusing properties. The calculations, starting from first principles, were compared with measured beam sizes and found to be in good agreement. Application to fountain experiments, atomic clocks, and focusing polar molecules in strong-field-seeking states is discussed.« less
Dynamics of focused femtosecond laser pulse during photodisruption of crystalline lens
NASA Astrophysics Data System (ADS)
Gupta, Pradeep Kumar; Singh, Ram Kishor; Sharma, R. P.
2018-04-01
Propagation of laser pulses of femtosecond time duration (focused through a focusing lens inside the crystalline lens) has been investigated in this paper. Transverse beam diffraction, group velocity dispersion, graded refractive index structure of the crystalline lens, self-focusing, and photodisruption in which plasma is formed due to the high intensity of laser pulses through multiphoton ionization have been taken into account. The model equations are the modified nonlinear Schrödinger equation along with a rate equation that takes care of plasma generation. A close analysis of model equations suggests that the femtosecond laser pulse duration is critical to the breakdown in the lens. Our numerical simulations reveal that the combined effect of self-focusing and multiphoton ionization provides the breakdown threshold. During the focusing of femtosecond laser pulses, additional spatial pulse splitting arises along with temporal splitting. This splitting of laser pulses arises on account of self-focusing, laser induced breakdown, and group velocity distribution, which modifies the shape of laser pulses. The importance of the present study in cavitation bubble generation to improve the elasticity of the eye lens has also been discussed in this paper.
An alternative approach to depth of field which avoids the blur circle and uses the pixel pitch
NASA Astrophysics Data System (ADS)
Schuster, Norbert
2015-09-01
Modern thermal imaging systems apply more and more uncooled detectors. High volume applications work with detectors which have a reduced pixel count (typical between 200x150 and 640x480). This shrinks the application of modern image treatment procedures like wave front coding. On the other hand side, uncooled detectors demand lenses with fast F-numbers near 1.0. Which are the limits on resolution if the target to analyze changes its distance to the camera system? The aim to implement lens arrangements without any focusing mechanism demands a deeper quantification of the Depth of Field problem. The proposed Depth of Field approach avoids the classic "accepted image blur circle". It bases on a camera specific depth of focus which is transformed in the object space by paraxial relations. The traditional RAYLEIGH's -criterion bases on the unaberrated Point Spread Function and delivers a first order relation for the depth of focus. Hence, neither the actual lens resolution neither the detector impact is considered. The camera specific depth of focus respects a lot of camera properties: Lens aberrations at actual F-number, detector size and pixel pitch. The through focus MTF is the base of the camera specific depth of focus. It has a nearly symmetric course around the maximum of sharp imaging. The through focus MTF is considered at detector's Nyquist frequency. The camera specific depth of focus is this the axial distance in front and behind of sharp image plane where the through focus MTF is <0.25. This camera specific depth of focus is transferred in the object space by paraxial relations. It follows a general applicable Depth of Field diagram which could be applied to lenses realizing a lateral magnification range -0.05…0. Easy to handle formulas are provided between hyperfocal distance and the borders of the Depth of Field in dependence on sharp distances. These relations are in line with the classical Depth of Field-theory. Thermal pictures, taken by different IR-camera cores, illustrate the new approach. The quite often requested graph "MTF versus distance" choses the half Nyquist frequency as reference. The paraxial transfer of the through focus MTF in object space distorts the MTF-curve: hard drop at closer distances than sharp distance, smooth drop at further distances. The formula of a general Diffraction-Limited-Through-Focus-MTF (DLTF) is deducted. Arbitrary detector-lens combinations could be discussed. Free variables in this analysis are waveband, aperture based F-number (lens) and pixel pitch (detector). The DLTF- discussion provides physical limits and technical requirements. The detector development with pixel pitches smaller than captured wavelength in the LWIR-region generates a special challenge for optical design.
Magnetic lens apparatus for a low-voltage high-resolution electron microscope
Crewe, Albert V.
1996-01-01
A lens apparatus in which a beam of charged particles of low accelerating voltage is brought to a focus by a magnetic field, the lens being situated behind the target position. The lens comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. The lens apparatus comprises the sole focusing lens for high-resolution imaging in a low-voltage scanning electron microscope.
Focus-tunable liquid cylindrical lens based on electrowetting
NASA Astrophysics Data System (ADS)
Tan, Yanting; Peng, Runling
2017-10-01
The double-liquid focus-tunable lens based on electrowetting on dielectrics is attracting many researchers' attention because of compact volume, quick responding speed, low consumption etc. In this paper, a focus-tunable liquid cylindrical lens based on electrowetting is designed, the structure and operating principles of this lens are introduced. COMSOL Multiphysics is chamber, and the focal length is varied continuously. According to the materials used in our laboratory, the focal length is estimated, ranging between (-∞, -38.6mm)υ(61.4mm, +∞).
Fabrication and Characterization of Flexible Electrowetting on Dielectrics (EWOD) Microlens
Li, Chenhui; Jiang, Hongrui
2014-01-01
We present a flexible variable-focus converging microlens actuated by electrowetting on dielectric (EWOD). The microlens is made of two immiscible liquids and a soft polymer, polydimethylsiloxane (PDMS). Parylene intermediate layer is used to produce robust flexible electrode on PDMS. A low-temperature PDMS-compatible fabrication process has been developed to reduce the stress on the lens structure. The lens has been demonstrated to be able to conform to curved surfaces smoothly. The focal length of the microlens is 29–38 mm on a flat surface, and 31–41 mm on a curved surface, varying with the voltage applied. The resolving power of the microlens is 25.39 line pairs per mm by a 1951 United States Air Force (USAF) resolution chart and the lens aberrations are measured by a Shack-Hartmann wavefront sensor. The focal length behavior on a curved surface is discussed and for the current lens demonstrated the focal length is slightly longer on the curved surface as a result of the effect of the curved PDMS substrate. PMID:25360324
Mutations and mechanisms in congenital and age-related cataracts
Shiels, Alan; Hejtmancik, J. Fielding
2017-01-01
The crystalline lens plays an important role in the refractive vision of vertebrates by facilitating variable fine focusing of light onto the retina. Loss of lens transparency, or cataract, is a frequently acquired cause of visual impairment in adults and may also present during childhood. Genetic studies have identified mutations in over 30 causative genes for congenital or other early-onset forms of cataract as well as several gene variants associated with age-related cataract. However, the pathogenic mechanisms resulting from genetic determinants of cataract are only just beginning to be understood. Here, we briefly summarize current concepts pointing to differences in the molecular mechanisms underlying congenital and age-related forms of cataract. PMID:27334249
Copper crystal lens for medical imaging: first results
NASA Astrophysics Data System (ADS)
Roa, Dante E.; Smither, Robert K.
2001-06-01
A copper crystal lens designed to focus gamma ray energies of 100 to 200 keV has been assembled at Argonne National Laboratory. In particular, the lens has been optimized to focus the 140.6 keV gamma rays from technetium-99 m typically used in radioactive tracers. This new approach to medical imaging relies on crystal diffraction to focus incoming gamma rays in a manner similar to a simple convex lens focusing visible light. The lens is envisioned to be part of an array of lenses that can be used as a complementary technique to gamma cameras for localized scans of suspected tumor regions in the body. In addition, a 2- lens array can be used to scan a woman's breast in search of tumors with no discomfort to the patient. The incoming gamma rays are diffracted by a set of 828 copper crystal cubes arranged in 13 concentric rings, which focus the gamma rays into a very small area on a well-shielded NaI detector. Experiments performance with technetium-99 m and cobalt 57 radioactive sources indicate that a 6-lens array should be capable of detecting sources with (mu) Ci strength.
Application and System Design of Elastomer Based Optofluidic Lenses
NASA Astrophysics Data System (ADS)
Savidis, Nickolaos
Adaptive optic technology has revolutionized real time correction of wavefront aberrations. Optofluidic based applied optic devices have offered an opportunity to produce flexible refractive lenses in the correction of wavefronts. Fluidic lenses have superiority relative to their solid lens counterparts in their capabilities of producing tunable optical systems, that when synchronized, can produce real time variable systems with no moving parts. We have developed optofluidic fluidic lenses for applications of applied optical devices, as well as ophthalmic optic devices. The first half of this dissertation discusses the production of fluidic lenses as optical devices. In addition, the design and testing of various fluidic systems made with these components are evaluated. We begin with the creation of spherical or defocus singlet fluidic lenses. We then produced zoom optical systems with no moving parts by synchronizing combinations of these fluidic spherical lenses. The variable power zoom system incorporates two singlet fluidic lenses that are synchronized. The coupled device has no moving parts and has produced a magnification range of 0.1 x to 10 x or a 20 x magnification range. The chapter after fluidic zoom technology focuses on producing achromatic lens designs. We offer an analysis of a hybrid diffractive and refractive achromat that offers discrete achromatized variable focal lengths. In addition, we offer a design of a fully optofluidic based achromatic lens. By synchronizing the two membrane surfaces of the fluidic achromat we develop a design for a fluidic achromatic lens. The second half of this dissertation discusses the production of optofluidic technology in ophthalmic applications. We begin with an introduction to an optofluidic phoropter system. A fluidic phoropter is designed through the combination of a defocus lens with two cylindrical fluidic lenses that are orientated 45° relative to each other. Here we discuss the designs of the fluidic cylindrical lens coupled with a previously discussed defocus singlet lens. We then couple this optofluidic phoropter with relay optics and Shack-Hartmann wavefront sensing technology to produce an auto-phoropter device. The auto-phoropter system combines a refractometer designed Shack-Hartmann wavefront sensor with the compact refractive fluidic lens phoropter. This combination allows for the identification and control of ophthalmic cylinder, cylinder axis, as well as refractive error. The closed loop system of the fluidic phoropter with refractometer enables for the creation of our see-through auto-phoropter system. The design and testing of several generations of transmissive see-through auto-phoropter devices are presented in this section.
Crystal diffraction lens with variable focal length
Smither, R.K.
1991-04-02
A method and apparatus for altering the focal length of a focusing element of one of a plurality of pre-determined focal lengths by changing heat transfer within selected portions of the element by controlled quantities is disclosed. Control over heat transfer is accomplished by manipulating one or more of a number of variables, including: the amount of heat or cold applied to surfaces; type of fluids pumped through channels for heating and cooling; temperatures, directions of flow and rates of flow of fluids; and placement of channels. 19 figures.
The performance of magnetic lens for focusing VCN-SANS
NASA Astrophysics Data System (ADS)
Nop Collaboration; Yamada, M.; Iwashita, Y.; Kanaya, T.; Ichikawa, M.; Tongu, H.; Kennedy, S. J.; Shimizu, H. M.; Mishima, K.; Yamada, N. L.; Hirota, K.; Carpenter, J. M.; Lal, J.; Andersen, K.; Geltenbort, P.; Guerard, B.; Manzin, G.; Hino, M.; Kitaguchi, M.; Bleuel, M.; NOP Collaboration
2011-04-01
We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5×104T/m2⩽g‧⩽5.9×104T/m2. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS.We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source (≈3mm) over a wavelength range of 30Å⩽λ⩽48Å in focal length of ≈1.14m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO)100(PPO)65(PEO)100 tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.
Flat liquid crystal diffractive lenses with variable focus and magnification
NASA Astrophysics Data System (ADS)
Valley, Pouria
Non-mechanical variable lenses are important for creating compact imaging devices. Various methods employing dielectrically actuated lenses, membrane lenses, and liquid crystal lenses were previously proposed [1-4]. In This dissertation the design, fabrication, and characterization of innovative flat tunable-focus liquid crystal diffractive lenses (LCDL) are presented. LCDL employ binary Fresnel zone electrodes fabricated on Indium-Tin-Oxide using conventional micro-photolithography. The light phase can be adjusted by varying the effective refractive index of a nematic liquid crystal sandwiched between the electrodes and a reference substrate. Using a proper voltage distribution across various electrodes the focal length can be changed between several discrete values. Electrodes are shunted such that the correct phase retardation step sequence is achieved. If the number of 2pi zone boundaries is increased by a factor of m the focal length is changed from f to f/m based on the digitized Fresnel zone equation: f = rm2/2mlambda, where r m is mth zone radius, and lambda is the wavelength. The chromatic aberration of the diffractive lens is addressed and corrected by adding a variable fluidic lens. These LCDL operate at very low voltage levels (+/-2.5V ac input), exhibit fast switching times (20-150 ms), can have large apertures (>10 mm), and small form factor, and are robust and insensitive to vibrations, gravity, and capillary effects that limit membrane and dielectrically actuated lenses. Several tests were performed on the LCDL including diffraction efficiency measurement, switching dynamics, and hybrid imaging with a refractive lens. Negative focal lengths are achieved by adjusting the voltages across electrodes. Using these lenses in combination, magnification can be changed and zoom lenses can be formed. These characteristics make LCDL a good candidate for a variety of applications including auto-focus and zoom lenses in compact imaging devices such as camera phones. A business plan centered on this technology was developed as part of the requirements for the minor in entrepreneurship from the Eller College of Management. An industrial analysis is presented in this study that involves product development, marketing, and financial analyses (Appendix I).
Algorithm design of liquid lens inspection system
NASA Astrophysics Data System (ADS)
Hsieh, Lu-Lin; Wang, Chun-Chieh
2008-08-01
In mobile lens domain, the glass lens is often to be applied in high-resolution requirement situation; but the glass zoom lens needs to be collocated with movable machinery and voice-coil motor, which usually arises some space limits in minimum design. In high level molding component technology development, the appearance of liquid lens has become the focus of mobile phone and digital camera companies. The liquid lens sets with solid optical lens and driving circuit has replaced the original components. As a result, the volume requirement is decreased to merely 50% of the original design. Besides, with the high focus adjusting speed, low energy requirement, high durability, and low-cost manufacturing process, the liquid lens shows advantages in the competitive market. In the past, authors only need to inspect the scrape defect made by external force for the glass lens. As to the liquid lens, authors need to inspect the state of four different structural layers due to the different design and structure. In this paper, authors apply machine vision and digital image processing technology to administer inspections in the particular layer according to the needs of users. According to our experiment results, the algorithm proposed can automatically delete non-focus background, extract the region of interest, find out and analyze the defects efficiently in the particular layer. In the future, authors will combine the algorithm of the system with automatic-focus technology to implement the inside inspection based on the product inspective demands.
Crewe, Albert V.
2000-01-01
Disclosed are lens apparatus in which a beam of charged particlesis brought to a focus by means of a magnetic field, the lens being situated behind the target position. In illustrative embodiments, a lens apparatus is employed in a scanning electron microscopeas the sole lens for high-resolution focusing of an electron beam, and in particular, an electron beam having an accelerating voltage of from about 10 to about 30,000 V. In one embodiment, the lens apparatus comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. In other embodiments, the lens apparatus comprises a magnetic dipole or virtual magnetic monopole fabricated from a variety of materials, including permanent magnets, superconducting coils, and magnetizable spheres and needles contained within an energy-conducting coil. Multiple-array lens apparatus are also disclosed for simultaneous and/or consecutive imaging of multiple images on single or multiple specimens. The invention further provides apparatus, methods, and devices useful in focusing charged particle beams for lithographic processes.
Flat Lens Focusing Demonstrated With Left-Handed Metamaterial
NASA Technical Reports Server (NTRS)
Wilson, Jeffrey D.; Schwartz, Zachary D.; Chevalier, Christine T.; Downey, Alan N.; Vaden, Karl R.
2004-01-01
Left-handed metamaterials (LHM's) are a new media engineered to possess an effective negative index of refraction over a selected frequency range. This characteristic enables LHM's to exhibit physical properties never before observed. In particular, a negative index of refraction should cause electromagnetic radiation to refract or bend at a negative angle when entering an LHM, as shown in the figure above on the left. The figure on the right shows that this property could be used to bring radiation to a focus with a flat LHM lens. The advantage of a flat lens in comparison to a conventional curved lens is that the focal length could be varied simply by adjusting the distance between the lens and the electromagnetic wave source. In this in-house work, researchers at the NASA Glenn Research Center developed a computational model for LHM's with the three-dimensional electromagnetic commercial code Microwave Studio, constructed an LHM flat lens, and used it to experimentally demonstrate the reversed refraction and flat lens focusing of microwave radiation.
NASA Astrophysics Data System (ADS)
Berge, Bruno; Broutin, Jérôme; Gaton, Hilario; Malet, Géraldine; Simon, Eric; Thieblemont, Florent
2013-03-01
This paper presents experimental results on several liquid lenses based on Electrowetting which are commercially available. It will be shown that larger aperture lenses are basically of the same optical quality than smaller lenses, sometimes reaching the diffraction limit, then opening new kind of applications areas for variable lenses in laser science. Regarding response time, actual performances of liquids lenses based on Electrowetting are presented and compared to a model simulating the internal fluid reorganization, seen as the main source of delay between electrical actuation and optical evolution of the lens. This simplified analytical model is supporting experimental results in various situations (focus and tilt variations), in static and dynamic regimes.
Plasma lens experiments at the Final Focus Test Beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barletta, B.; Chattopadhyay, S.; Chen, P.
1993-04-01
We intend to carry out a series of plasma lens experiments at the Final Focus Test Beam facility at SLAC. These experiments will be the first to study the focusing of particle beams by plasma focusing devices in the parameter regime of interest for high energy colliders, and is expected to lead to plasma lens designs capable of unprecedented spot sizes. Plasma focusing of positron beams will be attempted for the first time. We will study the effects of lens aberrations due to various lens imperfections. Several approaches will be applied to create the plasma required including laser ionization andmore » beam ionization of a working gas. At an increased bunch population of 2.5 {times} 10{sup 10}, tunneling ionization of a gas target by an electron beam -- an effect which has never been observed before -- should be significant. The compactness of our device should prove to be of interest for applications at the SLC and the next generation linear colliders.« less
Electrostatic plasma lens for focusing negatively charged particle beams.
Goncharov, A A; Dobrovolskiy, A M; Dunets, S M; Litovko, I V; Gushenets, V I; Oks, E M
2012-02-01
We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.
Increase in velocimeter depth of focus through astigmatism. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erskine, D.J.
1995-09-26
Frequently, velocimeter targets are illuminated by a laser beam passing through a hole in a mirror. This mirror is responsible for diverting returning light from a target lens to a velocity interferometer system for any reflector (VISAR). This mirror is often a significant distance from the target lens. Consequently, at certain target focus positions the returning light is strongly vignetted by the hole, causing a loss of signal. The authors find that they can prevent loss of signal and greatly increase the useful depth of focus by attaching a cylindrical lens to the target lens.
Electrostatic lens to focus an ion beam to uniform density
Johnson, Cleland H.
1977-01-11
A focusing lens for an ion beam having a gaussian or similar density profile is provided. The lens is constructed to provide an inner zero electrostatic field, and an outer electrostatic field such that ions entering this outer field are deflected by an amount that is a function of their distance from the edge of the inner field. The result is a beam that focuses to a uniform density in a manner analogous to that of an optical ring lens. In one embodiment, a conically-shaped network of fine wires is enclosed within a cylindrical anode. The wire net together with the anode produces a voltage field that re-directs the outer particles of the beam while the axial particles pass undeflected through a zero field inside the wire net. The result is a focused beam having a uniform intensity over a given target area and at a given distance from the lens.
High spatial resolution with zoomable saw-tooth refractive lenses?
NASA Astrophysics Data System (ADS)
Jark, Werner
2011-09-01
Refractive x-ray lenses can be assembled from two opposing saw-tooth structures, when they are inclined with respect to each other and almost touch at one end. An incident plane wave will then traverse a varying number of triangular prisms, which direct the beam towards the optical axis and focus it. Optically speaking the plane wave traverses a parabolic lens profile, which is approximated by trapezoidal segments. The parabolic profile will focus ideally, when a lens can be discussed in the "thin lens" approximation. Now the saw-tooth refractive lens is found to be too "thick". The residual aberrations limit the focusing capability to just submicrometer focusing, significantly above the limit in diffraction limited focusing. It is shown that the aberrations can be removed by introducing a variation into the originally constant saw-tooth angle. After this modification the lens can be operated in the diffraction limited regime. Spot sizes even below 0.1 micrometer are then feasible. This performance in terms of spatial resolution is found to be limited to focusing to microspots and is not available, when the saw-tooth refractive lens is used in an imaging setup. In this case the spatial resolution deteriorates rapidly with increasing off axis distance of the object to be imaged.
NASA Astrophysics Data System (ADS)
Tang, Huiqin; Zhu, Kaicheng
2013-12-01
Based on the generalized Huygens-Fresnel diffraction integral, a closed-form propagation equation related to sine-Gaussian beams through a cylindrical lens and a focusing lens is derived and illustrated with numerical methods. It is found that a sine-Gaussian beam through such a system may be converted into a dark hollow beam (DHB) with topological charge index one and its bright enclosure is approximately an elongated ellipse with very high ellipticity. Moreover, the parameter values at which the DHBs have perfect intensity patterns are designed. The optimal relative orientation between the dislocation line of the input sine-Gaussian beam and the axial orientation of the cylindrical lens is specified. And the ellipticity of the elliptical DHBs is mainly defined by the focal length of the cylindrical lens and the Fresnel number of the optical system.
Apparatus and method for combining light from two or more fibers into a single fiber
Klingsporn, Paul Edward
2007-02-20
An apparatus and method for combining light signals carried on a plurality of input fibers onto a single receiving fiber with a high degree of efficiency. The apparatus broadly comprises the receiving fiber and a plurality of input fiber-lens assemblies, with each fiber lens assembly including an input fiber; a collimating lens interposed between the input fiber and the receiving fiber and adapted to collimate the light signal; and a focusing lens interposed between the collimating lens and the receiving fiber and adapted to focus the collimated light signal onto the face of the receiving fiber. The components of each fiber-lens assembly are oriented along an optic axis that is inclined relative to the receiving fiber, with the inclination angle depending at least in part on the input fiber's numerical aperture and the focal lengths and diameters of the collimating and focusing lenses.
Apparatus and method for combining light from two or more fibers into a single fiber
Klingsporn, Paul Edward
2006-03-14
An apparatus and method for combining light signals carried on a plurality of input fibers onto a single receiving fiber with a high degree of efficiency. The apparatus broadly comprises the receiving fiber and a plurality of input fiber-lens assemblies, with each fiber lens assembly including an input fiber; a collimating lens interposed between the input fiber and the receiving fiber and adapted to collimate the light signal; and a focusing lens interposed between the collimating lens and the receiving fiber and adapted to focus the collimated light signal onto the face of the receiving fiber. The components of each fiber-lens assembly are oriented along an optic axis that is inclined relative to the receiving fiber, with the inclination angle depending at least in part on the input fiber's numerical aperture and the focal lengths and diameters of the collimating and focusing lenses.
Fast-response variable focusing micromirror array lens
NASA Astrophysics Data System (ADS)
Boyd, James G., IV; Cho, Gyoungil
2003-07-01
A reflective type Fresnel lens using an array of micromirrors is designed and fabricated using the MUMPs® surface micromachining process. The focal length of the lens can be rapidly changed by controlling both the rotation and translation of electrostatically actuated micromirrors. The rotation converges rays and the translation adjusts the optical path length difference of the rays to be integer multiples of the wavelength. The suspension spring, pedestal and electrodes are located under the mirror to maximize the optical efficiency. Relations are provided for the fill-factor and the numerical aperture as functions of the lens diameter, the mirror size, and the tolerances specified by the MUMPs® design rules. The fabricated lens is 1.8mm in diameter, and each micromirror is approximately 100mm x 100mm. The lens fill-factor is 83.7%, the numerical aperture is 0.018 for a wavelength of 632.8nm, and the resolution is approximately 22mm, whereas the resolution of a perfect aberration-free lens is 21.4μm for a NA of 0.018. The focal length ranges from 11.3mm to infinity. The simulated Strehl ratio, which is the ratio of the point spread function maximum intensity to the theoretical diffraction-limited PSF maximum intensity, is 31.2%. A mechanical analysis was performed using the finite element code IDEAS. The combined maximum rotation and translation produces a maximum stress of 301MPa, below the yield strength of polysilicon, 1.21 to 1.65GPa. Potential applications include adaptive microscope lenses for scanning particle imaging velocimetry and a visually aided micro-assembly.
Murphy, Patricia; Kabir, Md Humayun; Srivastava, Tarini; Mason, Michele E.; Dewi, Chitra U.; Lim, Seakcheng; Yang, Andrian; Djordjevic, Djordje; Killingsworth, Murray C.; Ho, Joshua W. K.; Harman, David G.
2018-01-01
ABSTRACT Cataracts cause vision loss and blindness by impairing the ability of the ocular lens to focus light onto the retina. Various cataract risk factors have been identified, including drug treatments, age, smoking and diabetes. However, the molecular events responsible for these different forms of cataract are ill-defined, and the advent of modern cataract surgery in the 1960s virtually eliminated access to human lenses for research. Here, we demonstrate large-scale production of light-focusing human micro-lenses from spheroidal masses of human lens epithelial cells purified from differentiating pluripotent stem cells. The purified lens cells and micro-lenses display similar morphology, cellular arrangement, mRNA expression and protein expression to human lens cells and lenses. Exposing the micro-lenses to the emergent cystic fibrosis drug Vx-770 reduces micro-lens transparency and focusing ability. These human micro-lenses provide a powerful and large-scale platform for defining molecular disease mechanisms caused by cataract risk factors, for anti-cataract drug screening and for clinically relevant toxicity assays. PMID:29217756
Murphy, Patricia; Kabir, Md Humayun; Srivastava, Tarini; Mason, Michele E; Dewi, Chitra U; Lim, Seakcheng; Yang, Andrian; Djordjevic, Djordje; Killingsworth, Murray C; Ho, Joshua W K; Harman, David G; O'Connor, Michael D
2018-01-09
Cataracts cause vision loss and blindness by impairing the ability of the ocular lens to focus light onto the retina. Various cataract risk factors have been identified, including drug treatments, age, smoking and diabetes. However, the molecular events responsible for these different forms of cataract are ill-defined, and the advent of modern cataract surgery in the 1960s virtually eliminated access to human lenses for research. Here, we demonstrate large-scale production of light-focusing human micro-lenses from spheroidal masses of human lens epithelial cells purified from differentiating pluripotent stem cells. The purified lens cells and micro-lenses display similar morphology, cellular arrangement, mRNA expression and protein expression to human lens cells and lenses. Exposing the micro-lenses to the emergent cystic fibrosis drug Vx-770 reduces micro-lens transparency and focusing ability. These human micro-lenses provide a powerful and large-scale platform for defining molecular disease mechanisms caused by cataract risk factors, for anti-cataract drug screening and for clinically relevant toxicity assays. © 2018. Published by The Company of Biologists Ltd.
Numerical analyses of planer plasmonic focusing lens
NASA Astrophysics Data System (ADS)
Chou, Yen-Yu; Lee, Yeeu-Chang
2018-03-01
The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.
Expected performances of a Laue lens made with bent crystals
NASA Astrophysics Data System (ADS)
Virgilli, Enrico; Valsan, Vineeth; Frontera, Filippo; Caroli, Ezio; Liccardo, Vincenzo; Stephen, John Buchan
2017-10-01
In the context of the Laue project devoted to build a Laue lens prototype for focusing celestial hard x-/soft gamma-rays, a Laue lens made of bent crystal tiles, with 20-m focal length, is simulated. The focusing energy passband is assumed to be 90 to 600 keV. The distortion of the image produced by the lens on the focal plane, due to effects of crystal tile misalignment and radial distortion of the crystal curvature, is investigated. The corresponding effective area of the lens, its point spread function, and sensitivity are calculated and compared with those exhibited by a nominal Laue lens with no misalignment and/or distortion. Such analysis is crucial to estimate the optical properties of a real lens, in which the investigated shortcomings could be present.
Increase in velocimeter depth of focus through astigmatism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erskine, D.J.
1996-05-01
Frequently, velocimeter targets are illuminated by a laser beam passing through a hole in a mirror. This mirror is responsible for diverting returning light from a target lens to a velocity interferometer system for any reflector (VISAR). This mirror is often a significant distance from the target lens. Consequently, at certain target focus positions the returning light is strongly vignetted by the hole, causing a loss of signal. We find that we can prevent loss of signal and greatly increase the useful depth of focus by attaching a cylindrical lens to the target lens. {copyright} {ital 1996 American Institute ofmore » Physics.}« less
NASA Astrophysics Data System (ADS)
Lizotte, Todd E.
2011-03-01
Over the years, technological achievements within the laser medical diagnostic, treatment, and therapy markets have led to ever increasing requirements for greater control of critical laser beam parameters. Increased laser power/energy stabilization, temporal and spatial beam shaping and flexible laser beam delivery systems with ergonomic focusing or imaging lens systems are sought by leading medical laser system producers. With medical procedures that utilize laser energy, there is a constant emphasis on reducing adverse effects that come about by the laser itself or its optical system, but even when these variables are well controlled the medical professional will still need to deal with the multivariate nature of the human body. Focusing on the variables that can be controlled, such as accurate placement of the laser beam where it will expose a surface being treated as well as laser beam shape and uniformity is critical to minimizing adverse conditions. This paper covers the use of fiber optic beam delivery as a means of defining the beam shape (intensity/power distribution uniformity) at the target plane as well as the use of fiber delivery as a means to allow more flexible articulation of the laser beam over the surface being treated. The paper will present a new concept of using a square core fiber beam delivery design utilizing a unique micro lens array (MLA) launch method that improves the overall stability of the system, by minimizing the impact of the laser instability. The resulting performance of the prototype is presented to demonstrate its stability in comparison to simple lens launch techniques, with an emphasis on homogenization and articulated fiber delivery.
Mikš, Antonín; Novák, Pavel
2018-05-10
In this article, we analyze the problem of the paraxial design of an active optical element with variable focal length, which maintains the positions of its principal planes fixed during the change of its optical power. Such optical elements are important in the process of design of complex optical systems (e.g., zoom systems), where the fixed position of principal planes during the change of optical power is essential for the design process. The proposed solution is based on the generalized membrane tunable-focus fluidic lens with several membrane surfaces.
NASA Technical Reports Server (NTRS)
Wilkerson, Gary W.; Huegele, Vinson
1998-01-01
The Marshall Space Flight Center (MSFC) has been developing a space deployable, lightweight membrane concentrator to focus solar energy into a solar furnace while remaining aligned to the sun. For an inner surface, this furnace has a cylindrical heat exchanger cavity coaligned to the optical axis; the furnace warms gas to propel the spacecraft. The membrane concentrator is a 1727 mm (68.00 in.) diameter, F/1.7 Fresnel lens. This large membrane is made from polyimide and is 0.076 mm (0.0030 in.) thick; it has the Fresnel grooves cast into it. The solar concentrator system has a super fast paraboloid reflector near the lens focus and immediately adjacent to the cylindrical exchanger cavity. The paraboloid collects the wide bandwidth and some of the solar energy scattered by the Fresnel lens. Finally, the paraboloid feeds the light into the cylinder. The Fresnel lens also possesses a narrow annular zone that focuses a reference beam toward four detectors that keep the optical system aligned to the sun; thus, occurs a refracting lens that focuses two places! The result can be summarized as a composite Fresnel lens for solar concentration and alignment.
Self-sustained focusing of high-density streaming plasma
NASA Astrophysics Data System (ADS)
Bugaev, A.; Dobrovolskiy, A.; Goncharov, A.; Gushenets, V.; Litovko, I.; Naiko, I.; Oks, E.
2017-01-01
We describe our observations of the transport through an electrostatic plasma lens of a wide-aperture, high-current, low energy, metal-ion plasma flow produced by a cathodic arc discharge. The lens input aperture was 80 mm, the length of the lens was 140 mm, and there were three electrostatic ring electrodes located in a magnetic field formed by permanent magnets. The lens outer electrodes were grounded and the central electrode was biased up to -3 kV. The plasma was a copper plasma with directed (streaming) ion energy 20-40 eV, and the equivalent ion current was up to several amperes depending on the potential applied to the central lens electrode. We find that when the central lens electrode is electrically floating, the current density of the plasma flow at the lens focus increases by up to 40%-50%, a result that is in good agreement with a theoretical treatment based on plasma-optical principles of magnetic insulation of electrons and equipotentialization along magnetic field lines. When the central lens electrode is biased negatively, an on-axis stream of energetic electrons is formed, which can also provide a mechanism for focusing of the plasma flow. Optical emission spectra under these conditions show an increase in intensity of lines corresponding to both copper atoms and singly charged copper ions, indicating the presence of fast electrons within the lens volume. These energetic electrons, as well as accumulating on-axis and providing ion focusing, can also assist in reducing the microdroplet component in the dense, low-temperature, metal plasma.
An electrostatically and a magnetically confined electron gun lens system
NASA Technical Reports Server (NTRS)
Bernius, Mark T.; Man, Kin F.; Chutjian, Ara
1988-01-01
Focal properties, electron trajectory calculations, and geometries are given for two electron 'gun' lens systems that have a variety of applications in, for example, electron-neutral and electron-ion scattering experiments. One nine-lens system utilizes only electrostatic confinement and is capable of focusing electrons onto a fixed target with extremely small divergence angles, over a range of final energies 1-790 eV. The second gun lens system is a simpler three-lens system suitable for use in a uniform, solenoidal magnetic field. While the focusing properties of such a magnetically confined lens systenm are simpler to deal with, the system does illustrate features of electron extraction and Brillouin flow that have not been suitably emphasized in the literature.
Effects of Iris Surface Curvature on Iris Recognition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Joseph T; Flynn, Patrick J; Bowyer, Kevin W
To focus on objects at various distances, the lens of the eye must change shape to adjust its refractive power. This change in lens shape causes a change in the shape of the iris surface which can be measured by examining the curvature of the iris. This work isolates the variable of iris curvature in the recognition process and shows that differences in iris curvature degrade matching ability. To our knowledge, no other work has examined the effects of varying iris curvature on matching ability. To examine this degradation, we conduct a matching experiment across pairs of images with varyingmore » degrees of iris curvature differences. The results show a statistically signi cant degradation in matching ability. Finally, the real world impact of these ndings is discussed« less
A plasma microlens for ultrashort high power lasers
NASA Astrophysics Data System (ADS)
Katzir, Yiftach; Eisenmann, Shmuel; Ferber, Yair; Zigler, Arie; Hubbard, Richard F.
2009-07-01
We present a technique for generation of miniature plasma lens system that can be used for focusing and collimating a high intensity femtosecond laser pulse. The plasma lens was created by a nanosecond laser, which ablated a capillary entrance. The spatial configuration of the ablated plasma focused a high intensity femtosecond laser pulse. This configuration offers versatility in the plasma lens small f-number for extremely tight focusing of high power lasers with no damage threshold restrictions of regular optical components.
Biconcave micro-optofluidic lens with low-refractive-index liquids.
Song, Chaolong; Nguyen, Nam-Trung; Asundi, Anand Krishna; Low, Cassandra Lee-Ngo
2009-12-01
One of the current problems of micro-optofluidics is the choice of a suitable liquid with a high refractive index (RI). We report the use of a low-RI liquid in a biconcave liquid-core liquid-cladding lens for focusing light. For the characterization of the lens, a telescope system was constructed from polydimethylsiloxane lenses to collimate and expand a light beam emitted from an optical fiber. The tunable optofluidic biconcave lens focuses the parallel beam. Fluorescent dye diluted in an index-matching liquid was used for the visualization of the light rays in a beam-tracing chamber. The focused beam is tuned by adjusting the flow rate ratio between core and cladding streams.
Theoretical investigations on a class of double-focus planar lens on the anisotropic material
NASA Astrophysics Data System (ADS)
Bozorgi, Mahdieh; Atlasbaf, Zahra
2017-05-01
We study a double-focus lens constituted of V-shaped plasmonic nano-antennas (VSPNAs) on the anisotropic TiO2 thin film. The phase and amplitude variations of cross-polarized scattered wave from a unit cell are computed by the developed fast Method of Moments (MoM) in which the dyadic Green's function is evaluated with the transmission line model in the spectral domain. Using the calculated phase and amplitude diagrams, a double-focus lens on the anisotropic thin film is designed in 2 μm. To validate the numerical results, the designed lens is analysed using a full-wave EM-solver. The obtained results show a tunable asymmetric behavior in the focusing intensity of the focal spots for different incident polarizations. It is shown that changing the thickness of anisotropic thin film leads to the changing in such an asymmetric behavior and also the intensity ratio of two focal spots. In addition, the lens performance is examined in the broadband wavelength range from 1.76 to 2.86 μm. It is achieved that the increasing the wavelength leads to decreasing the focal distances of the designed lens and increasing its numerical aperture (NA).
[Representation and mathematical analysis of human crystalline lens].
Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai
2011-01-01
The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.
Development of solid tunable optics for ultra-miniature imaging systems
NASA Astrophysics Data System (ADS)
Yongchao, Zou
This thesis focuses on the optimal design, fabrication and testing of solid tunable optics and exploring their applications in miniature imaging systems. It starts with the numerical modelling of such lenses, followed by the optimum design method and alignment tolerance analysis. A miniature solid tunable lens driven by a piezo actuator is then developed. To solve the problem of limited maximum optical power and tuning range in conventional lens designs, a novel multi-element solid tunable lens is proposed and developed. Inspired by the Alvarez principle, a novel miniature solid tunable dual-focus lens, which is designed using freeform surfaces and driven by one micro-electro-mechanical-systems (MEMS) rotary actuator, is demonstrated. To explore the applications of these miniature solid tunable lenses, a miniature adjustable-focus endoscope and one compact adjustable-focus camera module are developed. The adjustable-focus capability of these two miniature imaging systems is fully proved by electrically focusing targets placed at different positions.
Pink-beam focusing with a one-dimensional compound refractive lens
Dufresne, Eric M.; Dunford, Robert W.; Kanter, Elliot P.; ...
2016-07-28
The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X-ray beam to spatially overlap with an 80 µm-high low-density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm –2 was calculated. A CRL is chromatic so it does not efficiently focus X-rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment.more » A two-chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X-ray filter. As a result, a method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.« less
A light sheet confocal microscope for image cytometry with a variable linear slit detector
NASA Astrophysics Data System (ADS)
Hutcheson, Joshua A.; Khan, Foysal Z.; Powless, Amy J.; Benson, Devin; Hunter, Courtney; Fritsch, Ingrid; Muldoon, Timothy J.
2016-03-01
We present a light sheet confocal microscope (LSCM) capable of high-resolution imaging of cell suspensions in a microfluidic environment. In lieu of conventional pressure-driven flow or mechanical translation of the samples, we have employed a novel method of fluid transport, redox-magnetohydrodynamics (redox-MHD). This method achieves fluid motion by inducing a small current into the suspension in the presence of a magnetic field via electrodes patterned onto a silicon chip. This on-chip transportation requires no moving parts, and is coupled to the remainder of the imaging system. The microscopy system comprises a 450 nm diode 20 mW laser coupled to a single mode fiber and a cylindrical lens that converges the light sheet into the back aperture of a 10x, 0.3 NA objective lens in an epi-illumination configuration. The emission pathway contains a 150 mm tube lens that focuses the light onto the linear sensor at the conjugate image plane. The linear sensor (ELiiXA+ 8k/4k) has three lateral binning modes which enables variable detection aperture widths between 5, 10, or 20 μm, which can be used to vary axial resolution. We have demonstrated redox-MHD-enabled light sheet microscopy in suspension of fluorescent polystyrene beads. This approach has potential as a high-throughput image cytometer with myriad cellular diagnostic applications.
Multi-acoustic lens design methodology for a low cost C-scan photoacoustic imaging camera
NASA Astrophysics Data System (ADS)
Chinni, Bhargava; Han, Zichao; Brown, Nicholas; Vallejo, Pedro; Jacobs, Tess; Knox, Wayne; Dogra, Vikram; Rao, Navalgund
2016-03-01
We have designed and implemented a novel acoustic lens based focusing technology into a prototype photoacoustic imaging camera. All photoacoustically generated waves from laser exposed absorbers within a small volume get focused simultaneously by the lens onto an image plane. We use a multi-element ultrasound transducer array to capture the focused photoacoustic signals. Acoustic lens eliminates the need for expensive data acquisition hardware systems, is faster compared to electronic focusing and enables real-time image reconstruction. Using this photoacoustic imaging camera, we have imaged more than 150 several centimeter size ex-vivo human prostate, kidney and thyroid specimens with a millimeter resolution for cancer detection. In this paper, we share our lens design strategy and how we evaluate the resulting quality metrics (on and off axis point spread function, depth of field and modulation transfer function) through simulation. An advanced toolbox in MATLAB was adapted and used for simulating a two-dimensional gridded model that incorporates realistic photoacoustic signal generation and acoustic wave propagation through the lens with medium properties defined on each grid point. Two dimensional point spread functions have been generated and compared with experiments to demonstrate the utility of our design strategy. Finally we present results from work in progress on the use of two lens system aimed at further improving some of the quality metrics of our system.
Magnetic compound refractive lens for focusing and polarizing cold neutron beams.
Littrell, K C; te Velthuis, S G E; Felcher, G P; Park, S; Kirby, B J; Fitzsimmons, M R
2007-03-01
Biconcave cylindrical lenses are used to focus beams of x rays or neutrons using the refractive properties of matter. In the case of neutrons, the refractive properties of magnetic induction can similarly focus and simultaneously polarize the neutron beam without the concomitant attenuation of matter. This concept of a magnetic refractive lens was tested using a compound lens consisting of 99 pairs of cylindrical permanent magnets. The assembly successfully focused the intensity of a white beam of cold neutrons of one spin state at the detector, while defocusing the other. This experiment confirmed that a lens of this nature may boost the intensity locally by almost an order of magnitude and create a polarized beam. An estimate of the performance of a more practically dimensioned device suitable for incorporation in reflectometers and slit-geometry small angle scattering instruments is given.
Preliminary Investigation of an Active PLZT Lens
NASA Technical Reports Server (NTRS)
Lightsey, W. D.; Peters, B. R.; Reardon, P. J.; Wong, J. K.
2001-01-01
The design, analysis and preliminary testing of a prototype Adjustable Focus Optical Correction Lens (AFOCL) is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro-optic lens. The AFOCL was developed to perform optical re-alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories (ULSSO). The AFOCL has potential application as an active optical component within a larger optical system. As such, information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sensed wavefront to the desired shape and location. While offering variable and rapid focussing capability (controlled wavefront manipulation) similar to liquid crystal based spatial light modulators (SLM), the AFOCL offers some potential advantages because it is a solid-state, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometer wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. The data was analyzed and compared to theoretical data available from computer-based models of the AFOCL.
Optical compensation for night myopia based on dark focus and CA/C ratio.
Kotulak, J C; Morse, S E; Rabin, J C
1995-07-01
To determine whether individual differences in dark focus and convergence accommodation to convergence (CA/C) ratio can be used to prescribe the best optical correction for night myopia. The best correction for night myopia was obtained by measuring visual acuity and contrast sensitivity across a range of lens powers and luminances. Dark focus was measured with an infrared optometer, and CA/C ratio was measured with an infrared optometer and eyetracker. Only young subjects were used (mean age = 25.4 years). Optimal lens power was significantly correlated with dark focus, regardless of CA/C ratio. However, the slope of the regression line relating lens power to dark focus was steeper for subjects with CA/C ratios less than 0.4 diopters/meter angle (D/MA, n = 7) than for subjects with CA/C ratios greater than 0.4 D/MA (n = 9). The mean CA/C ratio for the entire sample (n = 16) was 0.59 D/MA. The mean optimal lens power and dark focus were -0.79 and 0.74 D, respectively, for the low CA/C group, and -0.60 and 0.91 D, respectively, for the high CA/C group. Visual performance in night myopia can be optimized by taking into account intersubject differences in dark focus and CA/C ratio. Best visual performance was found with a lens roughly equaling the full dark focus for subjects with low CA/C ratios and half the dark focus for subjects with high CA/C ratios.
Ring lens focusing and push-pull tracking scheme for optical disk systems
NASA Technical Reports Server (NTRS)
Gerber, R.; Zambuto, J.; Erwin, J. K.; Mansuripur, M.
1993-01-01
An experimental comparison of the ring lens and the astigmatic techniques of generating focus-error-signal (FES) in optical disk systems reveals that the ring lens generates a FES over two times steeper than that produced by the astigmat. Partly due to this large slope and, in part, because of its diffraction-limited behavior, the ring lens scheme exhibits superior performance characteristics. In particular the undesirable signal known as 'feedthrough' (induced on the FES by track-crossings during the seek operation) is lower by a factor of six compared to that observed with the astigmatic method. The ring lens is easy to align and has reasonable tolerance for positioning errors.
Analysis of a color-matching backlight system using a blazed grating and a lenticular lens array.
Son, Chang-Gyun; Gwag, Jin Seok; Lee, Jong Hoon; Kwon, Jin Hyuk
2012-12-20
A high efficiency LCD employing a color-matching backlight system that consists of a collimation lenticular lens sheet, a blazed grating, and a focusing lenticular lens array is proposed and analyzed. The RGB lights that are collimated and dispersed from the collimation lenticular lens sheet and the blazed grating are incident on the RGB color filters by the focusing lenticular lens array. The color-matched transmittance was increased 183% and 121% for divergence angles of 2° and 11°, respectively, compared to a conventional backlight that does not use a blazed grating. The design, simulation, and experimental results for the prototype color-matching backlight system are presented.
NASA Astrophysics Data System (ADS)
Zhang, Wei; Liu, Pengfei; Wei, Xiaona; Zhuang, Songlin; Yang, Bo
2010-11-01
Liquid lens is a novel optical device which can implement active zooming. With liquid lens, zoom camera can be designed with more miniature size and simpler structure than before. It is thought that the micro zoom system with liquid lens has a very wide potential applications in many fields, in which the volume and weight of the system are critically limited, such as endoscope, mobile, PDA and so on. There are mainly three types of tunable-focus liquid lens: liquid crystal lens, electrowetting effect based liquid lens and liquid-filled membrane lens. Comparing with the other two kinds of liquid lens, the liquid-filled membrane lens has the advantages of simple structure, flexible aperture and high zooming efficiency. But its membrane surface will have an initial shape deformation caused by the gravity when the aperture of the lens is at large size, which will lead to the wave front aberration and the imaging quality impairing. In this paper, the initial deformation of the lens caused by the gravity was simulated based on the theory of Elastic Mechanics, which was calculated by the Finite Element Analysis method. The relationship between the diameter of the lens and the wave front aberration caused by the gravity was studied. And the Optical path difference produced by different liquid density was also analyzed.
Broadband diffractive lens or imaging element
Ceglio, Natale M.; Hawryluk, Andrew M.; London, Richard A.; Seppala, Lynn G.
1991-01-01
A broadband diffractive lens or imaging element produces a sharp focus and/or a high resolution image with broad bandwidth illuminating radiation. The diffractive lens is sectored or segmented into regions, each of which focuses or images a distinct narrowband of radiation but all of which have a common focal length. Alternatively, a serial stack of minus filters, each with a diffraction pattern which focuses or images a distinct narrowband of radiation but all of which have a common focal length, is used. The two approaches can be combined. Multifocal broadband diffractive elements can also be formed.
Broadband and flexible acoustic focusing by metafiber bundles
NASA Astrophysics Data System (ADS)
Sun, Hong-Xiang; Chen, Jia-He; Ge, Yong; Yuan, Shou-Qi; Liu, Xiao-Jun
2018-06-01
We report a broadband and flexible acoustic focusing through metafiber bundles in air, in which each metafiber consists of eight circular and narrow rectangular cavities. The fractional bandwidth of the acoustic focusing could reach about 0.2, which arises from the eigenmodes of the metafiber structure. Besides, owing to the flexible characteristic of the metafibers, the focus position can be manipulated by bending the metafiber bundles, and the metafiber bundles could bypass rigid scatterers inside the lens structure. More interestingly, the acoustic propagation and focusing directions can be changed by using a designed right-angled direction converter fabricated by the metafibers, and a waveform converter and a focusing lens of the cylindrical acoustic source are realized based on the metafiber bundles. The proposed focusing lens has the advantages of broad bandwidth, flexible structure, and high focusing performance, showing great potentials in versatile applications.
NASA Technical Reports Server (NTRS)
Arbabi, Amir (Inventor); Faraon, Andrei (Inventor)
2018-01-01
A retroreflector device is described, which includes a lens component operable for focusing radiation, which is incident thereto at an angle of incidence. The retroreflector also includes a mirror component operable for reflecting the radiation focused by the lens component back along the angle of incidence. The lens component and/or the mirror component includes a quasi-periodic array of elements, each of which comprises a dimension smaller than a wavelength of the radiation.
NASA Technical Reports Server (NTRS)
Arbabi, Amir (Inventor); Faraon, Andrei (Inventor)
2016-01-01
A retroreflector device is described, which includes a lens component operable for focusing radiation, which is incident thereto at an angle of incidence. The retroreflector also includes a mirror component operable for reflecting the radiation focused by the lens component back along the angle of incidence. The lens component and/or the mirror component includes a quasi-periodic array of elements, each of which comprises a dimension smaller than a wavelength of the radiation.
Variable Permanent Magnet Quadrupole
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihara, T.; Iwashita, Y.; /Kyoto U.
A permanent magnet quadrupole (PMQ) is one of the candidates for the final focus lens in a linear collider. An over 120 T/m strong variable permanent magnet quadrupole is achieved by the introduction of saturated iron and a 'double ring structure'. A fabricated PMQ achieved 24 T integrated gradient with 20 mm bore diameter, 100 mm magnet diameter and 20 cm pole length. The strength of the PMQ is adjustable in 1.4 T steps, due to its 'double ring structure': the PMQ is split into two nested rings; the outer ring is sliced along the beam line into four partsmore » and is rotated to change the strength. This paper describes the variable PMQ from fabrication to recent adjustments.« less
2008-08-04
can also be initiated mechanically to produce variable lenses [9-11]. Recent work shows lens properties of a controlled liquid drop shape, with no... liquid crystal spherical lens ," Appl. Phys. Lett. 84, 4789-4791 (2004). 3. H. W. Ren, D. W. Fox, B. Wu, and S. T. Wu, " Liquid crystal lens with large...and S. S. Lee, "Focal tunable liquid lens integrated with an electromagnetic actuator," Appl. Phys. Lett. 90, 121129 (2007). 10. H. W. Ren, D. Fox
A passive autofocus system by using standard deviation of the image on a liquid lens
NASA Astrophysics Data System (ADS)
Rasti, Pejman; Kesküla, Arko; Haus, Henry; Schlaak, Helmut F.; Anbarjafari, Gholamreza; Aabloo, Alvo; Kiefer, Rudolf
2015-04-01
Today most of applications have a small camera such as cell phones, tablets and medical devices. A micro lens is required in order to reduce the size of the devices. In this paper an auto focus system is used in order to find the best position of a liquid lens without any active components such as ultrasonic or infrared. In fact a passive auto focus system by using standard deviation of the images on a liquid lens which consist of a Dielectric Elastomer Actuator (DEA) membrane between oil and water is proposed.
Design of laser afocal zoom expander system
NASA Astrophysics Data System (ADS)
Jiang, Lian; Zeng, Chun-Mei; Hu, Tian-Tian
2018-01-01
Laser afocal zoom expander system due to the beam diameter variable, can be used in the light sheet illumination microscope to observe the samples of different sizes. Based on the principle of afocal zoom system, the laser collimation and beam expander system with a total length of less than 110mm, 6 pieces of spherical lens and a beam expander ratio of 10 is designed by using Zemax software. The system is focused on laser with a wavelength of 532nm, divergence angle of less than 4mrad and incident diameter of 4mm. With the combination of 6 spherical lens, the beam divergence angle is 0.4mrad at the maximum magnification ratio, and the RMS values at different rates are less than λ/4. This design is simple in structure and easy to process and adjust. It has certain practical value.
Design and analysis of all-dielectric subwavelength focusing flat lens
NASA Astrophysics Data System (ADS)
Turduev, M.; Bor, E.; Kurt, H.
2017-09-01
In this letter, we numerically designed and experimentally demonstrated a compact photonic structure for the subwavelength focusing of light using all-dielectric absorption-free and nonmagnetic scattering objects distributed in an air medium. In order to design the subwavelength focusing flat lens, an evolutionary algorithm is combined with the finite-difference time-domain method for determining the locations of cylindrical scatterers. During the multi-objective optimization process, a specific objective function is defined to reduce the full width at half maximum (FWHM) and diminish side lobe level (SLL) values of light at the focal point. The time-domain response of the optimized flat lens exhibits subwavelength light focusing with an FWHM value of 0.19λ and an SLL value of 0.23, where λ denotes the operating wavelength of light. Experimental analysis of the proposed flat lens is conducted in a microwave regime and findings exactly verify the numerical results with an FWHM of 0.192λ and an SLL value of 0.311 at the operating frequency of 5.42 GHz. Moreover, the designed flat lens provides a broadband subwavelength focusing effect with a 9% bandwidth covering frequency range of 5.10 GHz-5.58 GHz, where corresponding FWHM values remain under 0.21λ. Also, it is important to note that the designed flat lens structure performs a line focusing effect. Possible applications of the designed structure in telecom wavelengths are speculated upon for future perspectives. Namely, the designed structure can perform well in photonic integrated circuits for different fields of applications such as high efficiency light coupling, imaging and optical microscopy, with its compact size and ability for strong focusing.
Parametric Shape Optimization of Lens-Focused Piezoelectric Ultrasound Transducers.
Thomas, Gilles P L; Chapelon, Jean-Yves; Bera, Jean-Christophe; Lafon, Cyril
2018-05-01
Focused transducers composed of flat piezoelectric ceramic coupled with an acoustic lens present an economical alternative to curved piezoelectric ceramics and are already in use in a variety of fields. Using a displacement/pressure (u/p) mixed finite element formulation combined with parametric level-set functions to implicitly define the boundaries between the materials and the fluid-structure interface, a method to optimize the shape of acoustic lens made of either one or multiple materials is presented. From that method, two 400 kHz focused transducers using acoustic lens were designed and built with different rapid prototyping methods, one of them made with a combination of two materials, and experimental measurements of the pressure field around the focal point are in good agreement with the presented model.
Luneburg lens in silicon photonics.
Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf
2011-03-14
The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms.
X-ray bubble lens and x-ray hollow plastic ball lens
NASA Astrophysics Data System (ADS)
Kohmura, Yoshiki; Awaji, Mitsuhiro; Suzuki, Yoshio; Ishikawa, Tetsuya
1998-11-01
Recent development of anew refractive x-ray lens at SPring-8 is reported. This is the first refractive x-ray lens with a string of spherical lens in-spite of the string of cylindrical holes. Two types of the lends were developed which consists of a string of bubbles formed in a viscous liquid and a string of hollow plastic balls on pure water. They are sealed inside a container made from an acrylic resin. The x-ray focusing properties were investigated with the monochromated beam at an undulator beam line BL47 in SPring-8. Demagnified images of the source for these tow types of lens were observed at the energy of 19.0-24.5 keV with the focal length of approximately 5m. For the bubble lens, a gain of about 12 was observed. The observed vertical image size, 48 micrometers , was 6 times larger than the expected size. The method to improve the focusing capability is discussed.
NASA Astrophysics Data System (ADS)
Zhang, Rumin; Liu, Peng; Liu, Dijun; Su, Guobin
2015-12-01
In this paper, we establish a forward simulation model of plenoptic camera which is implemented by inserting a micro-lens array in a conventional camera. The simulation model is used to emulate how the space objects at different depths are imaged by the main lens then remapped by the micro-lens and finally captured on the 2D sensor. We can easily modify the parameters of the simulation model such as the focal lengths and diameters of the main lens and micro-lens and the number of micro-lens. Employing the spatial integration, the refocused images and all-in-focus images are rendered based on the plenoptic images produced by the model. The forward simulation model can be used to determine the trade-offs between different configurations and to test any new researches related to plenoptic camera without the need of prototype.
Broadband diffractive lens or imaging element
Ceglio, Natale M.; Hawryluk, Andrew M.; London, Richard A.; Seppala, Lynn G.
1993-01-01
A broadband diffractive lens or imaging element produces a sharp focus and/or a high resolution image with broad bandwidth illuminating radiation. The diffractive lens is sectored or segmented into regions, each of which focuses or images a distinct narrowband of radiation but all of which have a common focal length. Alternatively, a serial stack of minus filters, each with a diffraction pattern which focuses or images a distinct narrowband of radiation but all of which have a common focal length, is used. The two approaches can be combined. Multifocal broadband diffractive elements can also be formed. Thin film embodiments are described.
Broadband diffractive lens or imaging element
Ceglio, N.M.; Hawryluk, A.M.; London, R.A.; Seppala, L.G.
1993-10-26
A broadband diffractive lens or imaging element produces a sharp focus and/or a high resolution image with broad bandwidth illuminating radiation. The diffractive lens is sectored or segmented into regions, each of which focuses or images a distinct narrowband of radiation but all of which have a common focal length. Alternatively, a serial stack of minus filters, each with a diffraction pattern which focuses or images a distinct narrowband of radiation but all of which have a common focal length, is used. The two approaches can be combined. Multifocal broadband diffractive elements can also be formed. Thin film embodiments are described. 21 figures.
Direct-to-digital holography and holovision
Thomas, Clarence E.; Baylor, Larry R.; Hanson, Gregory R.; Rasmussen, David A.; Voelkl, Edgar; Castracane, James; Simkulet, Michelle; Clow, Lawrence
2000-01-01
Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.
Virtual mask digital electron beam lithography
Baylor, L.R.; Thomas, C.E.; Voelkl, E.; Moore, J.A.; Simpson, M.L.; Paulus, M.J.
1999-04-06
Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made. 5 figs.
Virtual mask digital electron beam lithography
Baylor, Larry R.; Thomas, Clarence E.; Voelkl, Edgar; Moore, James A.; Simpson, Michael L.; Paulus, Michael J.
1999-01-01
Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.
Imaging Spectrometer Designs Utilizing Immersed Gratings With Accessible Entrance Slit
Chrisp, Michael P.; Lerner, Scott A.
2006-03-21
A compact imaging spectrometer comprises an entrance slit, a catadioptric lens with a mirrored surface, a grating, and a detector array. The entrance slit directs light to the mirrored surface of the catadioptric lens; the mirrored surface reflects the light back through the lens to the grating. The grating receives the light from the catadioptric lens and diffracts the light to the lens away from the mirrored surface. The lens transmits the light and focuses it onto the detector array.
NASA Astrophysics Data System (ADS)
Chen, Wei; Xu, Yue; Zhang, Huaxin; Liu, Peng; Jiao, Guohua
2016-09-01
Laser scanners are critical components in material processing systems, such as welding, cutting, and drilling. To achieve high-accuracy processing, the laser spot size should be small and uniform in the entire objective flat field. However, traditional static focusing method using F-theta objective lens is limited by the narrow flat field. To overcome these limitations, a dynamic focusing unit consisting of two lenses is presented in this paper. The dual-lens system has a movable plano-concave lens and a fixed convex lens. As the location of the movable optical elements is changed, the focal length is shifted to keep a small focus spot in a broad flat processing filed. The optical parameters of the two elements are theoretical analyzed. The spot size is calculated to obtain the relationship between the moving length of first lens and the shift focus length of the system. Also, the Zemax model of the optical system is built up to verify the theoretical design and optimize the optical parameter. The proposed lenses are manufactured and a test system is built up to investigate their performances. The experimental results show the spot size is smaller than 450um in all the 500*500mm 2 filed with CO2 laser. Compared with the other dynamic focusing units, this design has fewer lenses and no focusing spot in the optical path. In addition, the focal length minimal changes with the shit of incident laser beam.
Generation of scalable terahertz radiation from cylindrically focused two-color laser pulses in air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuk, D.; Yoo, Y. J.; Rosenthal, E. W.
2016-03-21
We demonstrate scalable terahertz (THz) generation by focusing terawatt, two-color laser pulses in air with a cylindrical lens. This focusing geometry creates a two-dimensional air plasma sheet, which yields two diverging THz lobe profiles in the far field. This setup can avoid plasma-induced laser defocusing and subsequent THz saturation, previously observed with spherical lens focusing of high-power laser pulses. By expanding the plasma source into a two-dimensional sheet, cylindrical focusing can lead to scalable THz generation. This scheme provides an energy conversion efficiency of 7 × 10{sup −4}, ∼7 times better than spherical lens focusing. The diverging THz lobes are refocused withmore » a combination of cylindrical and parabolic mirrors to produce strong THz fields (>21 MV/cm) at the focal point.« less
Resolution performance of a 0.60-NA, 364-nm laser direct writer
NASA Astrophysics Data System (ADS)
Allen, Paul C.; Buck, Peter D.
1990-06-01
ATEQ has developed a high resolution laser scanning printing engine based on the 8 beam architecture of the CORE- 2000. This printing engine has been incorporated into two systems: the CORE-2500 for the production of advanced masks and reticles and a prototype system for direct write on wafers. The laser direct writer incorporates a through-the-lens alignment system and a rotary chuck for theta alignment. Its resolution performance is delivered by a 0. 60 NA laser scan lens and a novel air-jet focus system. The short focal length high resolution lens also reduces beam position errors thereby improving overall pattern accuracy. In order to take advantage of the high NA optics a high performance focus servo was developed capable of dynamic focus with a maximum error of 0. 15 tm. The focus system uses a hot wire anemometer to measure air flow through an orifice abutting the wafer providing a direct measurement to the top surface of resist independent of substrate properties. Lens specifications are presented and compared with the previous design. Bench data of spot size vs. entrance pupil filling show spot size performance down to 0. 35 m FWHM. The lens has a linearity specification of 0. 05 m system measurements of lens linearity indicate system performance substantially below this. The aerial image of the scanned beams is measured using resist as a threshold detector. An effective spot size is
Role of parafovea in blur perception.
Venkataraman, Abinaya Priya; Radhakrishnan, Aiswaryah; Dorronsoro, Carlos; Lundström, Linda; Marcos, Susana
2017-09-01
The blur experienced by our visual system is not uniform across the visual field. Additionally, lens designs with variable power profile such as contact lenses used in presbyopia correction and to control myopia progression create variable blur from the fovea to the periphery. The perceptual changes associated with varying blur profile across the visual field are unclear. We therefore measured the perceived neutral focus with images of different angular subtense (from 4° to 20°) and found that the amount of blur, for which focus is perceived as neutral, increases when the stimulus was extended to cover the parafovea. We also studied the changes in central perceived neutral focus after adaptation to images with similar magnitude of optical blur across the image or varying blur from center to the periphery. Altering the blur in the periphery had little or no effect on the shift of perceived neutral focus following adaptation to normal/blurred central images. These perceptual outcomes should be considered while designing bifocal optical solutions for myopia or presbyopia. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Pitch variable liquid lens array using electrowetting
NASA Astrophysics Data System (ADS)
Kim, YooKwang; Lee, Jin Su; Kim, Junoh; Won, Yong Hyub
2017-02-01
These days micro lens array is used in various fields such as fiber coupling, laser collimation, imaging and sensor system and beam homogenizer, etc. One of important thing in using micro lens array is, choice of its pitch. Especially imaging systems like integral imaging or light-field camera, pitch of micro lens array defines the system property and thus it could limit the variability of the system. There are already researches about lens array using liquid, and droplet control by electrowetting. This paper reports the result of combining them, the liquid lens array that could vary its pitch by electrowetting. Since lens array is a repeated system, realization of a small part of lens array is enough to show its property. The lens array is composed of nine (3 by 3) liquid droplets on flat surface. On substrate, 11 line electrodes are patterned along vertical and horizontal direction respectively. The width of line electrodes is 300um and interval is 200um. Each droplet is positioned to contain three electrode lines for both of vertical and horizontal direction. So there is one remaining electrode line in each of outermost side for both direction. In original state the voltage is applied to inner electrodes. When voltage of outermost electrodes are turned on, eight outermost droplets move to outer side, thereby increasing pitch of lens array. The original pitch was 1.5mm and it increased to 2.5mm after electrodes of voltage applied is changed.
Tear analysis in contact lens wearers.
Farris, R L
1985-01-01
Tear analysis in contact lens wearers was compared with tear analysis in aphakics without contact lens wear and normal phakic patients. Subjects were divided into five groups: group 1, aphakic without contact lens; group 2, phakic with daily-wear hard contact lens; group 3, phakic with daily-wear soft contact lens; group 4, phakic with extended-wear soft contact lens; and group 5, aphakic with extended-wear soft contact lens. The experimental groups were compared with age- and sex-matched control groups for statistical analysis of tear variables by means of the Student's t-test. The variables measured were tear osmolarity, tear albumin, and lysozyme and lactoferrin concentrations in basal and reflex tears. Highly significant elevations of tear osmolarity were found in aphakic subjects without contact lenses. Less significant differences in tear osmolarity were found in phakic subjects with hard daily-wear lenses or with extended-wear soft lenses. Tear albumin, lysozyme, and lactoferrin in basal and reflex tears were not significantly different in the different groups of contact lens wearers or in the group of aphakic subjects without contact lenses compared with their control groups. Individual variations in tear albumin, lysozyme, and lactoferrin appeared to be responsible for the inability to demonstrate significant differences in tear composition in association with the wearing of different types of contact lenses. Older and aphakic patients demonstrated a tendency to have increased concentrations of proteins in the tears compared with younger, phakic contact lens wearers and normal controls without contact lenses. PMID:3914131
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stamate, Eugen, E-mail: eust@dtu.dk; Venture Business Laboratory, Nagoya University, C3-1, Chikusa-ku, Nagoya 464-8603; Yamaguchi, Masahito
2015-08-31
Modal and discrete focusing effects associated with three-dimensional plasma-sheath-lenses show promising potential for applications in ion beam extraction, mass spectrometry, plasma diagnostics and for basic studies of plasma sheath. The ion focusing properties can be adjusted by controlling the geometrical structure of the plasma-sheath-lens and plasma parameters. The positive and negative ion kinetics within the plasma-sheath-lens are investigated both experimentally and theoretically and a modal focusing ring is identified on the surface of disk electrodes. The focusing ring is very sensitive to the sheath thickness and can be used to monitor very small changes in plasma parameters. Three dimensional simulationsmore » are found to be in very good agreement with experiments.« less
NASA Astrophysics Data System (ADS)
Liu, Dan; Fu, Xiu-hua; Jia, Zong-he; Wang, Zhe; Dong, Huan
2014-08-01
In the high-energy laser test system, surface profile and finish of the optical element are put forward higher request. Taking a focusing aspherical zerodur lens with a diameter of 100mm as example, using CNC and classical machining method of combining surface profile and surface quality of the lens were investigated. Taking profilometer and high power microscope measurement results as a guide, by testing and simulation analysis, process parameters were improved constantly in the process of manufacturing. Mid and high frequency error were trimmed and improved so that the surface form gradually converged to the required accuracy. The experimental results show that the final accuracy of the surface is less than 0.5μm and the surface finish is □, which fulfils the accuracy requirement of aspherical focusing lens in optical system.
Wide-field computational imaging of pathology slides using lens-free on-chip microscopy.
Greenbaum, Alon; Zhang, Yibo; Feizi, Alborz; Chung, Ping-Luen; Luo, Wei; Kandukuri, Shivani R; Ozcan, Aydogan
2014-12-17
Optical examination of microscale features in pathology slides is one of the gold standards to diagnose disease. However, the use of conventional light microscopes is partially limited owing to their relatively high cost, bulkiness of lens-based optics, small field of view (FOV), and requirements for lateral scanning and three-dimensional (3D) focus adjustment. We illustrate the performance of a computational lens-free, holographic on-chip microscope that uses the transport-of-intensity equation, multi-height iterative phase retrieval, and rotational field transformations to perform wide-FOV imaging of pathology samples with comparable image quality to a traditional transmission lens-based microscope. The holographically reconstructed image can be digitally focused at any depth within the object FOV (after image capture) without the need for mechanical focus adjustment and is also digitally corrected for artifacts arising from uncontrolled tilting and height variations between the sample and sensor planes. Using this lens-free on-chip microscope, we successfully imaged invasive carcinoma cells within human breast sections, Papanicolaou smears revealing a high-grade squamous intraepithelial lesion, and sickle cell anemia blood smears over a FOV of 20.5 mm(2). The resulting wide-field lens-free images had sufficient image resolution and contrast for clinical evaluation, as demonstrated by a pathologist's blinded diagnosis of breast cancer tissue samples, achieving an overall accuracy of ~99%. By providing high-resolution images of large-area pathology samples with 3D digital focus adjustment, lens-free on-chip microscopy can be useful in resource-limited and point-of-care settings. Copyright © 2014, American Association for the Advancement of Science.
Tunable Liquid Gradient Refractive Index (L-GRIN) lens with two degrees of freedom.
Mao, Xiaole; Lin, Sz-Chin Steven; Lapsley, Michael Ian; Shi, Jinjie; Juluri, Bala Krishna; Huang, Tony Jun
2009-07-21
We report a tunable optofluidic microlens configuration named the Liquid Gradient Refractive Index (L-GRIN) lens for focusing light within a microfluidic device. The focusing of light was achieved through the gradient refractive index (GRIN) within the liquid medium, rather than via curved refractive lens surfaces. The diffusion of solute (CaCl(2)) between side-by-side co-injected microfluidic laminar flows was utilized to establish a hyperbolic secant (HS) refractive index profile to focus light. Tailoring the refractive index profile by adjusting the flow conditions enables not only tuning of the focal distance (translation mode), but also shifting of the output light direction (swing mode), a second degree of freedom that to our knowledge has yet to be accomplished for in-plane tunable microlenses. Advantages of the L-GRIN lens also include a low fluid consumption rate, competitive focusing performance, and high compatibility with existing microfluidic devices. This work provides a new strategy for developing integrative tunable microlenses for a variety of lab-on-a-chip applications.
Xu, Ji; Zhong, Yi; Wang, Shengming; Lu, Yunqing; Wan, Hongdan; Jiang, Jian; Wang, Jin
2015-10-19
Sub-wavelength focusing of cylindrical vector beams (CVBs) has attracted great attention due to the specific physical effects and the applications in many areas. More powerful, flexible and effective ways to modulate the focus transversally and also longitudinally are always being pursued. In this paper, cylindrically symmetric lens composed of negative-index one-dimensional photonic crystal is proposed to make a breakthrough. By revealing the relationship between focal length and the exit surface shape of the lens, a quite simple and effective principle of designing the lens structure is presented to realize specific focus modulation. Plano-concave lenses are parameterized to modulate the focal length and the number of focuses. An axicon constructed by one-dimensional photonic crystal is proposed for the first time to obtain a large depth of focus and an optical needle focal field with almost a theoretical minimum FWHM of 0.362λ is achieved under radially polarized incident light. Because of the almost identical negative refractive index for TE and TM polarization states, all the modulation methods can be applied for any arbitrary polarized CVBs. This work offers a promising methodology for designing negative-index lenses in related application areas.
Material Structure of a Graded Refractive Index Lens in Decapod Squid
NASA Astrophysics Data System (ADS)
Cai, Jing; Heiney, Paul; Sweeney, Alison
2013-03-01
Underwater vision with a camera-type eye that is simultaneously acute and sensitive requires a spherical lens with a graded distribution of refractive index. Squids have this type of lens, and our previous work has shown that its optical properties are likely achieved with radially variable densities of a single protein with multiple isoforms. Here we measure the spatial organization of this novel protein material in concentric layers of the lens and use these data to suggest possible mechanisms of self-assembly of the proteins into a graded refractive index structure. First, we performed small angle x-ray scattering (SAXS) to study how the protein is spatially organized. Then, molecular dynamic simulation allowed us to correlate structure to the possible dynamics of the system in different regions of the lens. The combination of simulation and SAXS data in this system revealed the likely protein-protein interactions, resulting material structure and its relationship to the observed and variable optical properties of this graded index system. We believe insights into the material properties of the squid lens system will inform the invention of self-assembling graded index devices.
Goos-Hänchen and Imbert-Fedorov shifts for astigmatic Gaussian beams
NASA Astrophysics Data System (ADS)
Ornigotti, Marco; Aiello, Andrea
2015-06-01
In this work we investigate the role of the beam astigmatism in the Goos-Hänchen and Imbert-Fedorov shift. As a case study, we consider a Gaussian beam focused by an astigmatic lens and we calculate explicitly the corrections to the standard formulas for beam shifts due to the astigmatism induced by the lens. Our results show that the different focusing in the longitudinal and transverse direction introduced by an astigmatic lens may enhance the angular part of the shift.
VCSEL End-Pumped Passively Q-Switched Nd:YAG Laser with Adjustable Pulse Energy
2011-02-28
entire VCSEL array. Neglecting lens aberrations, the focused spot diameter is given by focal length of the lens times the full divergence angle of the...pump intensity distribution generated by a pump-light-focusing lens . ©2011 Optical Society of America OCIS codes: (140.3530) Lasers Neodymium...Passive Q-Switch and Brewster Plate in a Pulsed Nd: YAG Laser,” IEEE J. Quantum Electron. 31(10), 1738–1741 (1995). 6. G. Xiao, and M. Bass, “A
Curiosity's Mars Hand Lens Imager (MAHLI): Inital Observations and Activities
NASA Technical Reports Server (NTRS)
Edgett, K. S.; Yingst, R. A.; Minitti, M. E.; Robinson, M. L.; Kennedy, M. R.; Lipkaman, L. J.; Jensen, E. H.; Anderson, R. C.; Bean, K. M.; Beegle, L. W.;
2013-01-01
MAHLI (Mars Hand Lens Imager) is a 2-megapixel focusable macro lens color camera on the turret on Curiosity's robotic arm. The investigation centers on stratigraphy, grain-scale texture, structure, mineralogy, and morphology of geologic materials at Curiosity's Gale robotic field site. MAHLI acquires focused images at working distances of 2.1 cm to infinity; for reference, at 2.1 cm the scale is 14 microns/pixel; at 6.9 cm it is 31 microns/pixel, like the Spirit and Opportunity Microscopic Imager (MI) cameras.
Diffraction limited focusing and routing of gap plasmons by a metal-dielectric-metal lens
Dennis, Brian S.; Czaplewski, David A.; Haftel, Michael I.; ...
2015-08-12
Passive optical elements can play key roles in photonic applications such as plasmonic integrated circuits. Here we experimentally demonstrate passive gap-plasmon focusing and routing in two-dimensions. This is accomplished using a high numerical-aperture metal-dielectric-metal lens incorporated into a planar-waveguide device. Fabrication via metal sputtering, oxide deposition, electron- and focused-ion- beam lithography, and argon ion-milling is reported on in detail. Diffraction-limited focusing is optically characterized by sampling out-coupled light with a microscope. The measured focal distance and full-width-half-maximum spot size agree well with the calculated lens performance. The surface plasmon polariton propagation length is measured by sampling light from multiple out-couplermore » slits.« less
Dynamic lens and monovision 3D displays to improve viewer comfort.
Johnson, Paul V; Parnell, Jared Aq; Kim, Joohwan; Saunter, Christopher D; Love, Gordon D; Banks, Martin S
2016-05-30
Stereoscopic 3D (S3D) displays provide an additional sense of depth compared to non-stereoscopic displays by sending slightly different images to the two eyes. But conventional S3D displays do not reproduce all natural depth cues. In particular, focus cues are incorrect causing mismatches between accommodation and vergence: The eyes must accommodate to the display screen to create sharp retinal images even when binocular disparity drives the eyes to converge to other distances. This mismatch causes visual discomfort and reduces visual performance. We propose and assess two new techniques that are designed to reduce the vergence-accommodation conflict and thereby decrease discomfort and increase visual performance. These techniques are much simpler to implement than previous conflict-reducing techniques. The first proposed technique uses variable-focus lenses between the display and the viewer's eyes. The power of the lenses is yoked to the expected vergence distance thereby reducing the mismatch between vergence and accommodation. The second proposed technique uses a fixed lens in front of one eye and relies on the binocularly fused percept being determined by one eye and then the other, depending on simulated distance. We conducted performance tests and discomfort assessments with both techniques and compared the results to those of a conventional S3D display. The first proposed technique, but not the second, yielded clear improvements in performance and reductions in discomfort. This dynamic-lens technique therefore offers an easily implemented technique for reducing the vergence-accommodation conflict and thereby improving viewer experience.
Compact imaging spectrometer utilizing immersed gratings
Lerner, Scott A.
2005-12-20
A compact imaging spectrometer comprising an entrance slit for directing light, lens means for receiving the light, refracting the light, and focusing the light; an immersed diffraction grating that receives the light from the lens means and defracts the light, the immersed diffraction grating directing the detracted light back to the lens means; and a detector that receives the light from the lens means.
Surface plasmon resonance sensor using vari-focal liquid lens under angular interrogation
NASA Astrophysics Data System (ADS)
Lee, Muyoung; Bang, Yousung; Lee, Jooho; Jang, Wonjae; Won, Yong Hyub
2017-02-01
In this paper, a surface plasmon resonance sensor for the detection of refractive index variation is presented. A novel waveguide type surface plasmon resonance sensing configuration with focal length variable liquid lens is introduced. The method of surface plasmon resonance sensor is based on the waveguide type with incident angle variation. The incident angle is varied by using an electrowetting liquid lens which is possible to actively change focal length as applying voltage. The optical system, which is adapted to electrowetting lens can continuously change the incident angle of light from 73 to 78 degrees with compact size. The surface plasmon waves are excited between metal and dielectric interface. The sensing surfaces are prepared by a coating of gold metal above high refractive index glass substrate. The incident light which is 532nm monochromatic light source passes through a noble metal coated substrate to detect intensity with incident angle variation. An analysis to distinguish the contribution of light with various incident angle is focused on the angular characteristics of the surface plasmon sensor under wavelength interrogation. The resonance angle is determined corresponding to sensing material refractive index with high sensitivity. The result suggests that the performance of surface plasmon resonance sensor can be improved by real time varying incident angle. From this presented study, it provides a different approach for angular interrogation surface plasmon resonance sensor and can be miniaturized for a portable device.
Gustafsson, Ola S E; Ekström, Peter; Kröger, Ronald H H
2012-07-01
Crystalline lenses with multiple focal lengths in monochromatic light (multifocal lenses) are present in many vertebrate groups. These lenses compensate for chromatic aberration and create well-focused color images. Stabilization of the lens within the eye and the ability to adjust focus are further requirements for vision in high detail. We investigated the occurrence of multifocal lenses by photorefractometry and lens suspension structures by light and electron microscopy in sturgeons (Acipenseriformes, Chondrostei) as well as sharks and rays (Elasmobranchii, Chondrichthyes). Multifocal lenses were found in two more major vertebrate groups, the Chondrostei represented by Acipenseriformes and Chondrichthyes represented by Elasmobranchii. The lens suspension structures of sturgeons, sharks, and rays are more complex than described previously. The lens is suspended by many delicate suspensory fibers in association with a ventral papilla in all groups studied. The arrangements of the suspensory fibers are most similar between sturgeons and sharks. In rays, the lens is suspended by a smaller ventral papilla and the suspensory fibers are arranged more concentrically to the lens. Copyright © 2012 Wiley Periodicals, Inc.
Method of preparing a tunable-focus liquid-crystal (LC) lens
NASA Astrophysics Data System (ADS)
Li, Xiaolong; Zhou, Zuowei; Ren, Hongwen
2018-02-01
A liquid crystal (LC) lens is prepared by controlling the alignment of a LC using a homogeneous polyimide (PI) layer and a homeotropic PI layer. The rubbed homogeneous PI layer has a concave surface and the homeotropic PI layer is flat. The LC sandwiched between the two PI layers obtains a hybrid alignment which has the largest gradient of refractive index (GRIN) distribution. The LC layer exhibits a lens character because of its convex shape. Since the effective refractive index of the LC is larger than that of the homogeneous PI, the LC lens can focus a light with the shortest focal length in the voltage-off state. By applying an external voltage, the LC molecules can be reoriented along the electric field. As a result, the focal length of the LC lens is reduced. The focal length of the LC lens can be tuned from 30 to 120 μm when the voltage is changed from 0 to 7 Vrms. This LC lens has the advantages of no threshold, low operating voltage, and simple fabrication.
Optimal focusing conditions of lenses using Gaussian beams
Franco, Juan Manuel; Cywiak, Moisés; Cywiak, David; ...
2016-04-02
By using the analytical equations of the propagation of Gaussian beams in which truncation exhibits negligible consequences, we describe a method that uses the value of the focal length of a focusing lens to classify its focusing performance. In this study, we show that for different distances between a laser and a focusing lens there are different planes where best focusing conditions can be obtained and we demonstrate how the value of the focal length impacts the lens focusing properties. To perform the classification we introduce the term delimiting focal length. As the value of the focal length used inmore » wave propagation theory is nominal and difficult to measure accurately, we describe an experimental approach to calculate its value matching our analytical description. Finally, we describe possible applications of the results for characterizing Gaussian sources, for measuring focal lengths and/or alternatively for characterizing piston-like movements.« less
Increase in velocimeter depth of focus through astigmatism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erskine, D.J.
1995-11-01
Frequently, velocimeter targets are illuminated by a laser beam passing through a hole in a mirror. This mirror is responsible for diverting returning light from a target lens to a velocity interferometer system for any reflector. This mirror is often a significant distance from the target lens. Consequently, at certain target focus positions the returning light is strongly vignetted by the hole, causing a loss of signal. This note finds that the loss of signal can be prevented and that the useful depth can be greatly increased by attaching a cylindrical lens to the target lens. {copyright} {ital 1995} {italmore » American} {ital Institute} {ital of} {ital Physics}.« less
Parabolic crossed planar polymeric x-ray lenses
NASA Astrophysics Data System (ADS)
Nazmov, V.; Reznikova, E.; Mohr, J.; Saile, V.; Vincze, L.; Vekemans, B.; Bohic, S.; Somogyi, A.
2011-01-01
The principles of design and manufacturing of the polymer planar x-ray lenses focusing in one and two directions, as well as the peculiarities of optical behaviors and the results of the lens test are reported in this paper. The methods of electron and deep x-ray lithography used in lens manufacturing allow the manufacture of ten or more x-ray lenses on one substrate; the lenses show focal lengths down to several centimeters for photon energies between 5 and 40 keV. The measured focus size was 105 nm for a linear lens with an intensity gain of about 407, and 300 × 770 nm for a crossed lens with an intensity gain of 6470.
Preliminary investigation of an active PLZT lens
NASA Astrophysics Data System (ADS)
Peters, Bruce R.; Reardon, Patrick J.; Wong, K. J.
2001-05-01
The design analysis and preliminary testing of a prototype AFOCL is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro- optic lens. The AFOCL was developed to perform optical re- alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories. The AFOCL would be an active optical component within a larger optical system. Information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sense4d wavefront tot he desired shape and location. While offering variable and rapid focusing capability similar to liquid crystal based spatial light modulators, the AFOCL offers some potential advantages because it is a solid-stat, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometers wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. Preliminary data was analyzed and compared to idealized performance available from computer-based models of the AFOCL.
Hard x-ray broad band Laue lenses (80-600 keV): building methods and performances
NASA Astrophysics Data System (ADS)
Virgilli, E.; Frontera, F.; Rosati, P.; Liccardo, V.; Squerzanti, S.; Carassiti, V.; Caroli, E.; Auricchio, N.; Stephen, J. B.
2015-09-01
We present the status of the LAUE project devoted to develop a technology for building a 20 meter long focal length Laue lens for hard X-/soft gamma-ray astronomy (80-600 keV). The Laue lens is composed of bent crystals of Gallium Arsenide (GaAs, 220) and Germanium (Ge, 111), and, for the first time, the focusing property of bent crystals has been exploited for this field of applications. We show the preliminary results concerning the adhesive employed to fix the crystal tiles over the lens support, the positioning accuracy obtained and possible further improvements. The Laue lens petal that will be completed in a few months has a pass band of 80-300 keV and is a fraction of an entire Laue lens capable of focusing x-rays up to 600 keV, possibly extendable down to ~20-30 keV with suitable low absorption crystal materials and focal length. The final goal is to develop a focusing optics that can improve the sensitivity over current telescopes in this energy band by 2 orders of magnitude.
The Columbia University Sub-micron Charged Particle Beam
Randers-Pehrson, Gerhard; Johnson, Gary W.; Marino, Stephen A.; Xu, Yanping; Dymnikov, Alexander D.; Brenner, David J.
2009-01-01
A lens system consisting of two electrostatic quadrupole triplets has been designed and constructed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. The lens system has been used to focus 6-MeV 4He ions to a beam spot in air with a diameter of 0.8 µm. The quadrupole electrodes can withstand voltages high enough to focus 4He ions up to 10 MeV and protons up to 5 MeV. The quadrupole triplet design is novel in that alignment is made through precise construction and the relative strengths of the quadrupoles are accomplished by the lengths of the elements, so that the magnitudes of the voltages required for focusing are nearly identical. The insulating sections between electrodes have had ion implantation to improve the voltage stability of the lens. The lens design employs Russian symmetry for the quadrupole elements. PMID:20161365
High numerical aperture multilayer Laue lenses
Morgan, Andrew J.; Prasciolu, Mauro; Andrejczuk, Andrzej; ...
2015-06-01
The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilise their capability for imaging and probing biological cells, nanodevices, and functional matter on the nanometer scale with chemical sensitivity. Here we demonstrate focusing a hard X-ray beam to an 8 nm focus using a volume zone plate (also referred to as a wedged multilayer Laue lens). This lens was constructed using a new deposition technique that enabled the independent control of the angle and thickness of diffracting layers to microradian and nanometer precision, respectively. This ensured that the Bragg condition is satisfied at each point along themore » lens, leading to a high numerical aperture that is limited only by its extent. We developed a phase-shifting interferometric method based on ptychography to characterise the lens focus. The precision of the fabrication and characterisation demonstrated here provides the path to efficient X-ray optics for imaging at 1 nm resolution.« less
Retinal optical coherence tomography at 1 μm with dynamic focus control and axial motion tracking
NASA Astrophysics Data System (ADS)
Cua, Michelle; Lee, Sujin; Miao, Dongkai; Ju, Myeong Jin; Mackenzie, Paul J.; Jian, Yifan; Sarunic, Marinko V.
2016-02-01
High-resolution optical coherence tomography (OCT) retinal imaging is important to noninvasively visualize the various retinal structures to aid in better understanding of the pathogenesis of vision-robbing diseases. However, conventional OCT systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking OCT system with automatic focus optimization for high-resolution, extended-focal-range clinical retinal imaging by incorporating a variable-focus liquid lens into the sample arm optics. Retinal layer tracking and selection was performed using a graphics processing unit accelerated processing platform for focus optimization, providing real-time layer-specific en face visualization. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the retina and optic nerve head, from which we extracted clinically relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.
Retinal optical coherence tomography at 1 μm with dynamic focus control and axial motion tracking.
Cua, Michelle; Lee, Sujin; Miao, Dongkai; Ju, Myeong Jin; Mackenzie, Paul J; Jian, Yifan; Sarunic, Marinko V
2016-02-01
High-resolution optical coherence tomography (OCT) retinal imaging is important to noninvasively visualize the various retinal structures to aid in better understanding of the pathogenesis of vision-robbing diseases. However, conventional OCT systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking OCT system with automatic focus optimization for high-resolution, extended-focal-range clinical retinal imaging by incorporating a variable-focus liquid lens into the sample arm optics. Retinal layer tracking and selection was performed using a graphics processing unit accelerated processing platform for focus optimization, providing real-time layer-specific en face visualization. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the retina and optic nerve head, from which we extracted clinically relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.
Combustion pinhole-camera system
Witte, A.B.
1982-05-19
A pinhole camera system is described utilizing a sealed optical-purge assembly which provides optical access into a coal combustor or other energy conversion reactors. The camera system basically consists of a focused-purge pinhole optical port assembly, a conventional TV vidicon receiver, an external, variable density light filter which is coupled electronically to the vidicon automatic gain control (agc). The key component of this system is the focused-purge pinhole optical port assembly which utilizes a purging inert gas to keep debris from entering the port and a lens arrangement which transfers the pinhole to the outside of the port assembly. One additional feature of the port assembly is that it is not flush with the interior of the combustor.
Combustion pinhole camera system
Witte, A.B.
1984-02-21
A pinhole camera system is described utilizing a sealed optical-purge assembly which provides optical access into a coal combustor or other energy conversion reactors. The camera system basically consists of a focused-purge pinhole optical port assembly, a conventional TV vidicon receiver, an external, variable density light filter which is coupled electronically to the vidicon automatic gain control (agc). The key component of this system is the focused-purge pinhole optical port assembly which utilizes a purging inert gas to keep debris from entering the port and a lens arrangement which transfers the pinhole to the outside of the port assembly. One additional feature of the port assembly is that it is not flush with the interior of the combustor. 2 figs.
Combustion pinhole camera system
Witte, Arvel B.
1984-02-21
A pinhole camera system utilizing a sealed optical-purge assembly which provides optical access into a coal combustor or other energy conversion reactors. The camera system basically consists of a focused-purge pinhole optical port assembly, a conventional TV vidicon receiver, an external, variable density light filter which is coupled electronically to the vidicon automatic gain control (agc). The key component of this system is the focused-purge pinhole optical port assembly which utilizes a purging inert gas to keep debris from entering the port and a lens arrangement which transfers the pinhole to the outside of the port assembly. One additional feature of the port assembly is that it is not flush with the interior of the combustor.
Short-focus and ultra-wide-angle lens design in wavefront coding
NASA Astrophysics Data System (ADS)
Zhang, Jiyan; Huang, Yuanqing; Xiong, Feibing
2016-10-01
Wavefront coding (WFC) is a hybrid technology designed to increase depth of field of conventional optics. The goal of our research is to apply this technology to the short-focus and ultra-wide-angle lens which suffers from the aberration related with large field of view (FOV) such as coma and astigmatism. WFC can also be used to compensate for other aberration which is sensitive to the FOV. Ultra-wide-angle lens has a little depth of focus because it has small F number and short-focus. We design a hybrid lens combing WFC with the ultra-wide-angle lens. The full FOV and relative aperture of the final design are up to170° and 1/1.8 respectively. The focal length is 2 mm. We adopt the cubic phase mask (CPM) in the design. The conventional design will have a wide variation of the point spread function (PSF) across the FOV and it is very sensitive with the variation of the FOV. The new design we obtain the PSF is nearly invariant over the whole FOV. But the result of the design also shows the little difference between the horizontal and vertical length of the PSF. We analyze that the CPM is non-symmetric phase mask and the FOV is so large, which will generate variation in the final image quality. For that reason, we apply a new method to avoid that happened. We try to make the rays incident on the CPM with small angle and decrease the deformation of the PSF. The experimental result shows the new method to optimize the CPM is fit for the ultra-wide-angle lens. The research above will be a helpful instruction to design the ultra-wide-angle lens with WFC.
NASA Astrophysics Data System (ADS)
Ferraro, Pietro; Grilli, Simonetta; Miccio, Lisa; Vespini, Veronica; Finizio, Sergio DeNicola Andrea
2008-11-01
In recent years a variety of liquid bases optical elements have been conceived, designed and fabricated even for commercial products like digital cameras o cellular phone cameras. The impressive development of microfluidic systems in conjunction with optics has led to the creation of a completely new Science field of investigation named optofludics. Optofludics, among others topics, deals with investigation and methods for realizing liquid micro-lenses. A variety of liquid micro-lenses have been designed and realized by using different configurations. We demonstrate that a lensing effect can be obtained in an open microfluidic system by using a thin layer of liquid on a polar electric crystal such as Lithium Niobate (LiNbO3). Electrowetting patterning on LiNbO3 surface is obtained by pyroelectric effect consisting in a simple but reliable electrodes-less and circuit-less configuration. The electrodes are intrinsically embedded into the substrate. The material is functionalised by means of a micro-engineering electric filed poling process. Lens array with variable focus has been demonstrated with a large number of lens elements (10x10) on micrometric scale (aperture of single lens 100 microns).
Correcting lenticular astigmatism by reinstating the correct neuromuscular message.
Yee, John William
2013-07-01
The spasm of the oblique muscles can contribute to lenticular astigmatism. The visual cortex interprets the tension of the oblique muscles as an eye that is in near focus mode. It overrides the response to the information generated by depth perception to bring a distant image into focus. Any excessive effort to bring it into focus will not be successful and continuing to make that effort can cause a misalignment in the tension of the rectus muscles. This in turn can directly induce corneal astigmatism and indirectly induce lenticular astigmatism. The astigmatic eye can still bring a near image into focus, but a distant image remains aberrant. The design of a special contact lens to treat lenticular astigmatism is similar to the design of a contact lens to treat corneal astigmatism by means of orthoculogy (or ortho C) as outlined in the paper Correcting Corneal Astigmatism by Reinstating the Correct Neuromuscular Message. The ortho C lens is worn for about two minutes to attend to the blur and distorted aspects of "simple myopic astigmatism". Both of these refractive errors are corrected simultaneously. Once the oblique muscles become "loose" due to a "contact lens draw", it triggers the visual cortex to reinstate the proper neuromotor message to stimulate the ciliary muscle (the muscle that controls the shape of the crystalline lens) to relax along a certain meridian-which in turn "flattens" the crystalline lens along that meridian to bring a blur and distorted image in the distance into focus. The correction only takes a few minutes because the ciliary muscle of an astigmatic eye was not compromised. The correction is not strictly due to an ortho C lens. Its design is the same for corneal astigmatism or lenticular astigmatism. The purpose of the design is to "loosen" the oblique muscles in a certain manner depending on the degree of astigmatism instead of a specific type of astigmatism. The visual cortex can discriminate whether to correct for corneal astigmatism or lenticular astigmatism after the "draw" from the lens relaxes the oblique muscles. Copyright © 2013 Elsevier Ltd. All rights reserved.
The "Youth Lens": Analyzing Adolescence/ts in Literary Texts
ERIC Educational Resources Information Center
Petrone, Robert; Sarigianides, Sophia Tatiana; Lewis, Mark A.
2014-01-01
Drawing from interdisciplinary scholarship that re-conceptualizes adolescence as a cultural construct, this article introduces a "Youth Lens." A "Youth Lens" comprises an approach to textual analysis that examines how ideas about adolescence and youth get formed, circulated, critiqued, and revised. Focused specifically on its…
Diffraction limited focusing and routing of gap plasmons by a metal-dielectric-metal lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dennis, Brian S.; Czaplewski, David A.; Haftel, Michael I.
2015-01-01
Passive optical elements can play key roles in photonic applications such as plasmonic integrated circuits. Here we experimentally demonstrate passive gap-plasmon focusing and routing in two-dimensions. This is accomplished using a high numerical-aperture metal-dielectric-metal lens incorporated into a planar-waveguide device. Fabrication via metal sputtering, oxide deposition, electron-and focused-ion-beam lithography, and argon ion-milling is reported on in detail. Diffraction-limited focusing is optically characterized by sampling out-coupled light with a microscope. The measured focal distance and full-width-half-maximum spot size agree well with the calculated lens performance. The surface plasmon polariton propagation length is measured by sampling light from multiple out-coupler slits. (C)more » 2015 Optical Society of America« less
Tunable-focus liquid lens controlled using a servo motor
NASA Astrophysics Data System (ADS)
Ren, Hongwen; Fox, David; Anderson, P. Andrew; Wu, Benjamin; Wu, Shin-Tson
2006-09-01
We demonstrated a liquid lens whose focal length can be controlled by an actuator. The lens cell is composed of elastic membrane, planar glass plate, a periphery sealing ring, and a liquid with a fixed volume in the lens chamber. Part of the periphery sealing ring is excavated to form a hollow chamber which functions as a reservoir. This hollowed periphery is surrounded by an exterior rubber membrane. The shaft of an actuator is used to deform the elastic rubber. Squeezing the liquid contained in the reservoir into the lens chamber. Excess liquid in the lens chamber will push the lens membrane to outward, resulting in a lens shape change. Due to the compact structure and easy operation, this liquid lens has potential applications in zoom lenses, auto beam steering, and eyeglasses.
NASA Astrophysics Data System (ADS)
Camattari, Riccardo
2017-09-01
Focusing a hard x-ray beam would represent an innovative technique for tumour treatment, since such a beam may deliver a dose to a tumour located at a given depth under the skin, sparing the surrounding healthy cells. A detailed study of a focusing system for hard x-ray aimed at radiotherapy is presented here. Such a focusing system, named Laue lens, exploits x-ray diffraction and consists of a series of crystals disposed as concentric rings capable of concentrating a flux of x-rays towards a focusing point. A feasibility study regarding the positioning tolerances of the crystalline optical elements has been carried out. It is shown that a Laue lens can effectively be used in the context of radiotherapy for tumour treatments provided that the mounting errors are below certain values, which are reachable in the modern micromechanics. An extended survey based on an analytical approach and on simulations is presented for precisely estimating all the contributions of each mounting error, analysing their effect on the focal spot of the Laue lens. Finally, a simulation for evaluating the released dose in a water phantom is shown.
Active Plasma Lensing for Relativistic Laser-Plasma-Accelerated Electron Beams
van Tilborg, J.; Steinke, S.; Geddes, C. G. R.; ...
2015-10-28
The compact, tunable, radially symmetric focusing of electrons is critical to laser-plasma accelerator (LPA) applications. Experiments are presented demonstrating the use of a discharge-capillary active plasma lens to focus 100-MeV-level LPA beams. The lens can provide tunable field gradients in excess of 3000 T/m, enabling cm-scale focal lengths for GeV-level beam energies and allowing LPA-based electron beams and light sources to maintain their compact footprint. For a range of lens strengths, excellent agreement with simulation was obtained.
Automatic optimization high-speed high-resolution OCT retinal imaging at 1μm
NASA Astrophysics Data System (ADS)
Cua, Michelle; Liu, Xiyun; Miao, Dongkai; Lee, Sujin; Lee, Sieun; Bonora, Stefano; Zawadzki, Robert J.; Mackenzie, Paul J.; Jian, Yifan; Sarunic, Marinko V.
2015-03-01
High-resolution OCT retinal imaging is important in providing visualization of various retinal structures to aid researchers in better understanding the pathogenesis of vision-robbing diseases. However, conventional optical coherence tomography (OCT) systems have a trade-off between lateral resolution and depth-of-focus. In this report, we present the development of a focus-stacking optical coherence tomography (OCT) system with automatic optimization for high-resolution, extended-focal-range clinical retinal imaging. A variable-focus liquid lens was added to correct for de-focus in real-time. A GPU-accelerated segmentation and optimization was used to provide real-time layer-specific enface visualization as well as depth-specific focus adjustment. After optimization, multiple volumes focused at different depths were acquired, registered, and stitched together to yield a single, high-resolution focus-stacked dataset. Using this system, we show high-resolution images of the ONH, from which we extracted clinically-relevant parameters such as the nerve fiber layer thickness and lamina cribrosa microarchitecture.
The Zoom Lens: A Case Study in Geometrical Optics.
ERIC Educational Resources Information Center
Cheville, Alan; Scepanovic, Misa
2002-01-01
Introduces a case study on a motion picture company considering the purchase of a newly developed zoom lens in which students act as the engineers designing the zoom lens based on the criteria of company's specifications. Focuses on geometrical optics. Includes teaching notes and classroom management strategies. (YDS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dufresne, Eric M.; Dunford, Robert W.; Kanter, Elliot P.
The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X-ray beam to spatially overlap with an 80 µm-high low-density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm –2 was calculated. A CRL is chromatic so it does not efficiently focus X-rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment.more » A two-chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X-ray filter. As a result, a method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.« less
A broadband terahertz ultrathin multi-focus lens
He, Jingwen; Ye, Jiasheng; Wang, Xinke; Kan, Qiang; Zhang, Yan
2016-01-01
Ultrathin transmission metasurface devices are designed on the basis of the Yang-Gu amplitude-phase retrieval algorithm for focusing the terahertz (THz) radiation into four or nine spots with focal spacing of 2 or 3 mm at a frequency of 0.8 THz. The focal properties are experimentally investigated in detail, and the results agree well with the theoretical expectations. The designed THz multi-focus lens (TMFL) demonstrates a good focusing function over a broad frequency range from 0.3 to 1.1 THz. As a transmission-type device based on metasurface, the diffraction efficiency of the TMFL can be as high as 33.92% at the designed frequency. The imaging function of the TMFL is also demonstrated experimentally and clear images are obtained. The proposed method produces an ultrathin, low-cost, and broadband multi-focus lens for THz-band application PMID:27346430
Objective Lens Optimized for Wavefront Delivery, Pupil Imaging, and Pupil Ghosting
NASA Technical Reports Server (NTRS)
Olzcak, Gene
2009-01-01
An interferometer objective lens (or diverger) may be used to transform a collimated beam into a diverging or converging beam. This innovation provides an objective lens that has diffraction-limited optical performance that is optimized at two sets of conjugates: imaging to the objective focus and imaging to the pupil. The lens thus provides for simultaneous delivery of a high-quality beam and excellent pupil resolution properties.
Sextupole system for the correction of spherical aberration
Crewe, A.V.; Kopf, D.A.
In an electron beam device in which an electron beam is developed and then focused by a lens to a particular spot, there is provided a means for eliminating spherical aberration. A sextupole electromagnetic lens is positioned between two focusing lenses. The interaction of the sextupole with the beam compensates for spherical aberration. (GHT)
Thermally tunable-focus lenticular lens using liquid crystal.
Heo, Kyong Chan; Yu, Seung Hun; Kwon, Jin Hyuk; Gwag, Jin Seog
2013-12-10
A thermally tunable focusing lenticular liquid crystal (LC) lens array was fabricated using a polymer LC component, including a polarizer that produces linearly polarized light. The focal length in the proposed structure could be tuned by temperature-adjusted applied voltage to a transparent heater in a lenticular LC lens cell because it alters the birefringence of the LC and varies the difference in refractive index between the LC and the polymer. The results showed that the focal length of the E7 LC used varied continuously with temperature from 5.6 to 8.7 mm from 25°C to 54°C, respectively. The proposed lenticular LC lens has potential use in photonic devices such as biological imaging, phone cameras, and optical sensors.
Electron Lens Construction for the Integrable Optics Test Accelerator at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGee, Mike; Carlson, Kermit; Nobrega, Lucy
The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. Construction of an electron lens for IOTA is necessary for both electron and proton operation. Components required for the Electron Lens design include; a 0.8 T conventional water-cooled main solenoid, and magnetic bending and focusing elements. The foundation of the design relies on repurposing the Fermilab Tevatron Electron Lens II (TELII)more » gun and collector under ultra-high vacuum (UHV) conditions.« less
NASA Astrophysics Data System (ADS)
Yamaoka, Yoshihisa; Kimura, Yuka; Harada, Yoshinori; Takamatsu, Tetsuro; Takahashi, Eiji
2018-02-01
Conventional one-photon photoacoustic microscopy (PAM) utilizes high-frequency components of generated photoacoustic waves to improve the depth resolution. However, to obtain optically-high resolution in PAM in the depth direction, the use of high-frequency ultrasonic waves is to be avoided. It is because that the propagation distance is shortened as the frequency of ultrasonic waves becomes high. To overcome this drawback, we have proposed and developed two-photon photoacoustic microscopy (TP-PAM). Two-photon absorption occurs only at the focus point. TPPAM does not need to use the high-frequency components of photoacoustic waves. Thus, TP-PAM can improve the penetration depth while preserving the spatial resolution. However, the image acquisition time of TP-PAM is longer than that of conventional PAM, because TP-PAM needs to scan the laser spot both in the depth and transverse directions to obtain cross-sectional images. In this paper, we have introduced a focus-tunable electrically-controlled liquid lens in TP-PAM. Instead of a mechanical stepping-motor stage, we employed electrically-controlled liquid lens so that the depth of the focus spot can be quickly changed. In our system, the imaging speed of TP-PAM using the liquid lens and one-axis stepping-motor stage was 10 times faster than that using a two-axis stepping-motor stage only. TP-PAM with focus-scanning head consisting of the liquid lens and stepping-motor stage will be a promising method to investigate the inside of living tissues.
Effect of variable tinted spectacle lenses on visual performance in control subjects.
Lee, Jason E; Stein, Jonathan J; Prevor, Meredith B; Seiple, William H; Holopigian, Karen; Greenstein, Vivienne C; Stenson, Susan M
2002-04-01
To evaluate quantitatively the effects of tinted spectacle lenses on visual performance in individuals without visual pathology. Twenty-five subjects were assessed by measuring contrast sensitivity with and without glare. Gray, brown, yellow, green, purple, and blue lens tints were evaluated. Measurements were repeated with each lens tint and with a clear lens, and the order was counterbalanced within and between subjects. Glare was induced with a modified brightness acuity tester. All subjects demonstrated an increase in contrast thresholds under glare conditions for all lens tints. However, purple and blue lens tints resulted in the least amount of contrast threshold increase; the yellow lens tint resulted in the largest contrast threshold increase. Purple and blue lens tints may improve contrast sensitivity in control subjects under glare conditions.
LC-lens array with light field algorithm for 3D biomedical applications
NASA Astrophysics Data System (ADS)
Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun
2016-03-01
In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.
Broadband unidirectional cloaks based on flat metasurface focusing lenses
NASA Astrophysics Data System (ADS)
Li, Yongfeng; Zhang, Jieqiu; Qu, Shaobo; Wang, Jiafu; Pang, Yongqiang; Xu, Zhuo; Zhang, Anxue
2015-08-01
Bandwidth extension and thickness reduction are now the two key issues of cloaks. In this paper, we propose to achieve broadband, thin uni-directional electromagnetic (EM) cloaks using metasurfaces. To this end, a wideband flat focusing lens is firstly devised based on high-efficiency transmissive metasurfaces. Due to the nearly dispersionless parabolic phase profile along the metasurface in the operating band, incident plane waves can be focused efficiently after passing through the metasurface. Broadband unidirectional EM cloaks were then designed by combining two identical flat lenses. Upon illumination, the incident plane waves are firstly focused by one lens and then are restored by the other lens, avoiding the cloaked region. Both simulation and experiment results verify the broadband unidirectional cloak. The broad bandwidth and small thickness of such cloaks have potential applications in achieving invisibility for electrically large objects.
A Business Of Security: Applying An Economic Model To Human Trafficking In Oregon
2016-12-01
presents policy analysis under a qualitative cost - benefit lens to assess economic model variables applied to state level policies. The conclusion is...modern slavery, sex trafficking, labor trafficking, Oregon, supply and demand, cost - benefit analysis 15. NUMBER OF PAGES 129 16. PRICE CODE 17...analyzing weaknesses and gaps. The thesis presents policy analysis under a qualitative cost - benefit lens to assess economic model variables applied to
NASA Astrophysics Data System (ADS)
Wang, Ying; Chen, Anmin; Wang, Qiuyun; Sui, Laizhi; Ke, Da; Cao, Sheng; Li, Suyu; Jiang, Yuanfei; Jin, Mingxing
2018-03-01
In this study, the influence of distance between the focusing lens and target surface on the plasma temperature of copper induced by a Nd:YAG laser was investigated in the atmosphere. The plasma temperature was calculated by using the Cu (I) lines (510.55 nm, 515.32 nm, and 521.82 nm). The Cu (I) lines were recorded under different lens-to-sample distances and laser pulse energies (15.8 mJ, 27.0 mJ, 43.4 mJ, 59.2 mJ, and 76.8 mJ). The results indicated that the plasma temperature depended strongly on the distance between the focusing lens and target surface. With the increase in the distance, the plasma temperature firstly rose, and then dropped. This could be attributed to the interaction between the tailing of the nanosecond laser pulse and the front portion of the plasma plume, the plasma shielding effect, and the expanding of the plasma. In addition, there was an interesting phenomenon that the plasma temperature and the emission intensity were not completely consistent with the change of the lens-to-sample distance. It is hoped that our research will provide a deeper insight into the underlying physical processes.
Hestian Hermeneutics: A Lens of Analysis for Home Economics.
ERIC Educational Resources Information Center
Thompson, Patricia J.
Feminist and women scholars in all disciplines have challenged the traditional masculist "lens of analysis" and have sought to bring into focus the "missing text" of female experience. This paper proposes an alternative to gender-bound lens of analysis because either or both masculist and feminist lenses are too limited to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalantar, D.
This document provides information on the distribution of unconverted light in the National Ignition Facility (NIF) target chamber with the wedged final focus lens that has been adopted by the NIF project. It includes a comparison of the wedged lens configuration with the color separation grating (CSG). There are significant benefits to the wedged lens design as it greatly simplifies experiment design.
Aging and Age-Related Diseases of the Ocular Lens and Vitreous Body
Petrash, J. Mark
2013-01-01
Reduced quality of life and financial burden due to visual impairment and blindness begin to increase dramatically when individuals reach the age of 40. The major causes of age-related vision loss can be traced to changes to the structure and function of the lens, one of the tissues responsible for focusing light on the retina. Age-related nuclear cataracts, which are caused by aggregation and condensation of proteins, diminish vision because they impede the transmission and focusing of light on the retina. In addition to the slow-developing age-related form, cataracts often develop rapidly as a complication of ocular surgery, such as following vitrectomy or as a consequence of vitreous gel degeneration. Posterior capsular opacification, which can develop following cataract removal, is caused by proliferation and inappropriate accumulation of lens epithelial cells on the surfaces of intraocular lenses and the posterior lens capsule. Presbyopia is a loss of accommodative amplitude and reduced ability to shift focus from far to near objects. Onset of presbyopia is associated with an increase in lens hardness and reduced ability of the lens to change shape in response to ciliary muscle contraction. Avenues of promising research that seek to delay or prevent these causes of low vision are discussed in light of our current understanding of disease pathogenesis and some challenges that must be met to achieve success. PMID:24335070
On the black hole lens and its foci
NASA Technical Reports Server (NTRS)
Eshleman, Von R.; Gurrola, Eric M.; Lindal, Gunnar F.
1989-01-01
Methods developed for radio occultation studies of planetary atmospheres are used to predict the electromagnetic focusing properties of a refracting lens representation of a Schwarzschild black hole. The infinity of foci are of three distinct types: a principal forward axial focus which is by far the strongest; higher-order forward axial foci; and backward conical foci with axial nulls.
Annular Focused Electron/Ion Beams for Combining High Spatial Resolution with High Probe Current.
Khursheed, Anjam; Ang, Wei Kean
2016-10-01
This paper presents a proposal for reducing the final probe size of focused electron/ion beam columns that are operated in a high primary beam current mode where relatively large final apertures are used, typically required in applications such as electron beam lithography, focused ion beams, and electron beam spectroscopy. An annular aperture together with a lens corrector unit is used to replace the conventional final hole-aperture, creating an annular ring-shaped primary beam. The corrector unit is designed to eliminate the first- and second-order geometric aberrations of the objective lens, and for the same probe current, the final geometric aberration limited spot size is predicted to be around a factor of 50 times smaller than that of the corresponding conventional hole-aperture beam. Direct ray tracing simulation is used to illustrate how a three-stage core lens corrector can be used to eliminate the first- and second-order geometric aberrations of an electric Einzel objective lens.
Sutter, John P.; Alianelli, Lucia
2017-01-01
The shapes of single lens surfaces capable of focusing divergent and collimated beams without aberration have already been calculated. However, nanofocusing compound refractive lenses (CRLs) require many consecutive lens surfaces. Here a theoretical example of an X-ray nanofocusing CRL with 48 consecutive surfaces is studied. The surfaces on the downstream end of this CRL accept X-rays that are already converging toward a focus, and refract them toward a new focal point that is closer to the surface. This case, so far missing from the literature, is treated here. The ideal surface for aberration-free focusing of a convergent incident beam is found by analytical computation and by ray tracing to be one sheet of a Cartesian oval. An ‘X-ray approximation’ of the Cartesian oval is worked out for the case of small change in index of refraction across the lens surface. The paraxial approximation of this surface is described. These results will assist the development of large-aperture CRLs for nanofocusing. PMID:29091055
NASA Astrophysics Data System (ADS)
Poppick, A. N.; McKinnon, K. A.; Dunn-Sigouin, E.; Deser, C.
2017-12-01
Initial condition climate model ensembles suggest that regional temperature trends can be highly variable on decadal timescales due to characteristics of internal climate variability. Accounting for trend uncertainty due to internal variability is therefore necessary to contextualize recent observed temperature changes. However, while the variability of trends in a climate model ensemble can be evaluated directly (as the spread across ensemble members), internal variability simulated by a climate model may be inconsistent with observations. Observation-based methods for assessing the role of internal variability on trend uncertainty are therefore required. Here, we use a statistical resampling approach to assess trend uncertainty due to internal variability in historical 50-year (1966-2015) winter near-surface air temperature trends over North America. We compare this estimate of trend uncertainty to simulated trend variability in the NCAR CESM1 Large Ensemble (LENS), finding that uncertainty in wintertime temperature trends over North America due to internal variability is largely overestimated by CESM1, on average by a factor of 32%. Our observation-based resampling approach is combined with the forced signal from LENS to produce an 'Observational Large Ensemble' (OLENS). The members of OLENS indicate a range of spatially coherent fields of temperature trends resulting from different sequences of internal variability consistent with observations. The smaller trend variability in OLENS suggests that uncertainty in the historical climate change signal in observations due to internal variability is less than suggested by LENS.
Simulation of light propagation in the thin-film waveguide lens
NASA Astrophysics Data System (ADS)
Malykh, M. D.; Divakov, D. V.; Sevastianov, L. A.; Sevastianov, A. L.
2018-04-01
In this paper we investigate the solution of the problem of modeling the propagation of electromagnetic radiation in three-dimensional integrated optical structures, such as waveguide lenses. When propagating through three-dimensional waveguide structures the waveguide modes can be hybridized, so the mathematical model of their propagation must take into account the connection of TE- and TM-mode components. Therefore, an adequate consideration of hybridization of the waveguide modes is possible only in vector formulation of the problem. An example of three-dimensional structure that hybridizes waveguide modes is the Luneburg waveguide lens, which also has focusing properties. If the waveguide lens has a radius of the order of several tens of wavelengths, its variable thickness at distances of the order of several wavelengths is almost constant. Assuming in this case that the electromagnetic field also varies slowly in the direction perpendicular to the direction of propagation, one can introduce a small parameter characterizing this slow varying and decompose the solution in powers of the small parameter. In this approach, in the zeroth approximation, scalar diffraction problems are obtained, the solution of which is less resource-consuming than the solution of vector problems. The calculated first-order corrections of smallness describe the connection of TE- and TM-modes, so the solutions obtained are weakly-hybridized modes. The formulation of problems and methods for their numerical solution in this paper are based on the authors' research on waveguide diffraction on a lens in a scalar formulation.
Vision of low astigmats through thick and thin lathe-cut soft contact lenses.
Cho, P; Woo, G C
2001-01-01
Distance and near visual acuity of 13 low astigmats were determined in a double-masked experiment through thick and thin (centre thickness 0.12 mm and 0.06 mm, respectively) spherical lathe-cut soft lenses. For each lens type, distance and near LogMAR VA and over-refraction were assessed with different logMAR VA charts. For 70% of the subjects, the residual astigmatism was significantly lower than the refractive astigmatism with thicker lenses. No statistically significant differences in the distance and near logMAR VA was found between the two lens types using any of the charts used, though, in general, logMAR VA obtained through the thicker lens was better than logMAR VA through the thinner lens. The variabilities in distance and near logMAR VA between the two lens types increased with decreased contrast. The variabilities in distance logMAR VA were greater with Chinese charts than with English charts, and LogMAR VA with Chinese charts were significantly worse for both lens types. Based on the results of this study, we concluded that thicker spherical lathe-cut soft lenses provide better vision in low astigmats. The Snellen acuity test is inadequate for vision assessment of soft contact lens wearers. When a patient wearing thin soft contact lenses complains of poor vision in spite of 6/6 or 6/5 Snellen acuity, changing to thicker lenses may be considered.
Invited review article: the electrostatic plasma lens.
Goncharov, Alexey
2013-02-01
The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.
Cellulose nanocrystal and poly[di(ethylene glycol) adipate] blend for tunable lens
NASA Astrophysics Data System (ADS)
Ko, Hyun-U.; Kim, Hyun Chan; Li, Yaguang; Kim, Sang Youn; Kim, Jaehwan
2016-04-01
In these days, consumer electronics and medical device for optical diagnosis are minimalized and mobilized. The focusing part is one of crucial parts of optical diagnosis systems to reduce the size and weight. Thus, demand for tunable lens that change the focus itself is increased. To meet the demand, many tunable lens has been studied by utilizing smart materials that responded under mechanical, magnetic, optical, thermal, chemical, electrical or electrochemical stimuli. This paper reports a cellulose nanocrystal (CNC) and poly[di(ethylene glycol) adipate] (PDEGA) blend that is able to respond under electromechanical stimulus. The preparation of CNC/PDEGA and its characterization are illustrated and its actuation behavior is tested . Because the material has high dielectric constant and high reflection index, it is good candidate material for tunable lens.
NASA Astrophysics Data System (ADS)
Hornburg, Kathryn J.; Kim, Jihwan; Escuti, Michael J.
2017-02-01
We report on the properties of a fast F/1.5 geometric-phase lens with a focal length of 37 mm at 633 nm and a 24.5 mm diameter. This lens employs photo-aligned liquid crystal layers to implement the spatially varying Pancharatnam-Berry phase, leading to the expected polarization- and wavelength-dependent focusing. An achromatic spectrum is achieved using (chiral nematic) multi-twist retarder coatings, with high first-order (>=98%) and low zero-order (<=1%) transmittance across 450-700 nm. We measure traditional optical metrics of the GP lens including focused spot profile and modulation transfer function through knife edge testing and NBS 1963a resolution charts. This work includes a comparison to similar F/# conventional thick and thin lenses.
NASA Astrophysics Data System (ADS)
Smith, Nathan Birchard
In this dissertation work, the aim was to garner better mechanistic understanding of how shock wave lithotripsy (SWL) breaks stones in order to guide design improvements to modern electromagnetic (EM) shock wave lithotripters. To accomplish this goal, experimental studies were carefully designed to isolate mechanisms of fragmentation, and models for wave propagation, fragmentation, and stone motion were developed. In the initial study, a representative EM lithotripter was characterized and tested for
A Telescope at the Solar Gravitational Lens: Problems and Solutions
NASA Technical Reports Server (NTRS)
Landis, Geoffrey A.
2017-01-01
Due to the bending of light by gravity, the gravity of sun forms a lens. In principle, a spacecraft sent to the distance of the solar gravitational focus could be used as a gravitational lens telescope. One example of such a mission would be to use the gravitational lens to image an extrasolar planet around a nearby star. The practical difficulties with this concept are discussed, and some approaches to mitigating these difficulties suggested.
Electron microscope aperture system
NASA Technical Reports Server (NTRS)
Heinemann, K. (Inventor)
1976-01-01
An electron microscope including an electron source, a condenser lens having either a circular aperture for focusing a solid cone of electrons onto a specimen or an annular aperture for focusing a hollow cone of electrons onto the specimen, and an objective lens having an annular objective aperture, for focusing electrons passing through the specimen onto an image plane are described. The invention also entails a method of making the annular objective aperture using electron imaging, electrolytic deposition and ion etching techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, E.M.; Masso, J.D.
This project involved the manufacturing of curved-faceted, injection-molded, four-element Fresnel lens parquets for concentrating photovoltaic arrays. Previous efforts showed that high-efficiency (greater than 82%) Fresnel concentrators could be injection molded. This report encompasses the mold design, molding, and physical testing of a four-lens parquet for a solar photovoltaic concentrator system.
Sanchez, Rick F; Dawson, Charlotte; Matas Riera, Màrian; Escanilla, Natàlia
2016-07-01
To introduce a new corneal clarity score for use in small animals and describe its inter- and intra-user variability. Twelve dogs and two cats with corneal abnormalities and five dogs with healthy corneas. Four examiners scored every patient twice and never consecutively, focusing on the central cornea. The peripheral cornea was scored separately. The following scoring system was used to describe corneal clarity: G0: no fundus reflection is visible on retroillumination (RI) using a head-mounted indirect ophthalmoscope. G1: a fundus reflection is visible with RI. G2: a 0.1-mm diameter light beam is visible on the anterior surface of the iris and/or lens. G3: gross fundic features are visible when viewed with indirect ophthalmoscopy (IO) using a head-mounted indirect ophthalmoscope and a hand-held 30D lens, although fine details are not clear. G4: fine details of the fundic features are clearly visible with IO. The minimum grades given were analyzed for inter- and intra-user variability with kappa analysis. Intra- and interuser variability of the central corneal clarity ranged from 0.78 to 0.96, showing substantial to almost perfect reproducibility, and from 0.66 to 0.91, showing substantial to almost perfect reliability, respectively. Intra- and interuser variability of the peripheral cornea ranged from 0.83 to 0.95, showing almost perfect agreement, and from 0.53 to 0.91, showing moderate to almost perfect agreement. The RVC-CCS is well suited to assess and monitor central corneal clarity in small animals and to compare outcomes between studies and different surgeons. © 2015 American College of Veterinary Ophthalmologists.
NASA Astrophysics Data System (ADS)
Simon, Eric; Craen, Pierre; Gaton, Hilario; Jacques-Sermet, Olivier; Laune, Frédéric; Legrand, Julien; Maillard, Mathieu; Tallaron, Nicolas; Verplanck, Nicolas; Berge, Bruno
2010-05-01
A new generation of liquid lenses based on electrowetting has been developed, using a multi-electrode design, enabling to induce optical tilt and focus corrections in the same component. The basic principle is to rely on a conical shape for supporting the liquid interface, the conical shape insuring a restoring force for the liquid liquid interface to come at the center position. The multi-electrode design enables to induce an average tilt of the liquid liquid interface when a bias voltage is applied to the different electrodes. This tilt is reversible, vanishing when voltage bias is cancelled. Possible application of this new lens component is the realization of miniature camera featuring auto-focus and optical image stabilization (OIS) without any mobile mechanical part. Experimental measurements of actual performances of liquid lens component will be presented : focus and tilt amplitude, residual optical wave front error and response time.
... and lens of your eye helps you focus. Refractive errors are vision problems that happen when the shape ... cornea, or aging of the lens. Four common refractive errors are Myopia, or nearsightedness - clear vision close up ...
Large aperture diffractive space telescope
Hyde, Roderick A.
2001-01-01
A large (10's of meters) aperture space telescope including two separate spacecraft--an optical primary objective lens functioning as a magnifying glass and an optical secondary functioning as an eyepiece. The spacecraft are spaced up to several kilometers apart with the eyepiece directly behind the magnifying glass "aiming" at an intended target with their relative orientation determining the optical axis of the telescope and hence the targets being observed. The objective lens includes a very large-aperture, very-thin-membrane, diffractive lens, e.g., a Fresnel lens, which intercepts incoming light over its full aperture and focuses it towards the eyepiece. The eyepiece has a much smaller, meter-scale aperture and is designed to move along the focal surface of the objective lens, gathering up the incoming light and converting it to high quality images. The positions of the two space craft are controlled both to maintain a good optical focus and to point at desired targets which may be either earth bound or celestial.
Ultrasonic fluid flow measurement method and apparatus
Kronberg, J.W.
1993-10-12
An apparatus for measuring the flow of a fluid in a pipe using ultrasonic waves. The apparatus comprises an ultrasonic generator, a lens for focusing the sound energy produced by the generator, and means for directing the focused energy into the side of the pipe through an opening and in a direction close to parallel to the long axis of the pipe. A cone carries the sound energy to the lens from the generator. Depending on the choice of materials, there may be a quarter-wave, acoustic impedance matching section between the generator and the cone to reduce the reflections of energy at the cone boundary. The lens material has an acoustic impedance similar to that of the cone material but a different sonic velocity so that the lens can converge the sound waves in the fluid. A transition section between the lens and the fluid helps to couple the energy to the fluid and assures it is directed as close to parallel to the fluid flow direction as possible. 3 figures.
Ultrasonic fluid flow measurement method and apparatus
Kronberg, James W.
1993-01-01
An apparatus for measuring the flow of a fluid in a pipe using ultrasonic waves. The apparatus comprises an ultrasonic generator, a lens for focusing the sound energy produced by the generator, and means for directing the focused energy into the side of the pipe through an opening and in a direction close to parallel to the long axis of the pipe. A cone carries the sound energy to the lens from the generator. Depending on the choice of materials, there may be a quarter-wave, acoustic impedance matching section between the generator and the cone to reduce the reflections of energy at the cone boundary. The lens material has an acoustic impedance similar to that of the cone material but a different sonic velocity so that the lens can converge the sound waves in the fluid. A transition section between the lens and the fluid helps to couple the energy to the fluid and assures it is directed as close to parallel to the fluid flow direction as possible.
Validating a new device for measuring tear evaporation rates.
Rohit, Athira; Ehrmann, Klaus; Naduvilath, Thomas; Willcox, Mark; Stapleton, Fiona
2014-01-01
To calibrate and validate a commercially available dermatology instrument to measure tear evaporation rate of contact lens wearers. A dermatology instrument was modified by attaching a swim goggle cup such that the cup sealed around the eye socket. Results for the unmodified instrument are dependent on probe area and enclosed volume. Calibration curves were established using a model eye, to account for individual variations in chamber volume and exposed area. Fifteen participants were recruited and the study included a contact lens wear and a no contact lens wear stage. Day and diurnal variation of the measurements were assessed by taking the measurement three times a day over 2 days. The coefficient of repeatability of the measurement was calculated and a linear mixed model assessed the influence of humidity, temperature, contact lens wear, day and diurnal variations on tear evaporation rate. The associations between variables were assessed using Pearson correlation coefficient. Absolute evaporation rates with and without contact lens wear were calculated based on the new calibration. The measurements were most repeatable during the evening with no lens wear (COR = 49 g m⁻² h) and least repeatable during the evening with contact lens wear (COR = 93 g m⁻² h). Humidity (p = 0.007), and contact lens wear (p < 0.01), significantly affected the tear evaporation rate. However, temperature (p = 0.54) diurnal variation (p = 0.85) and different days (p = 0.65) had no significant effect after controlling for humidity. Tear evaporation rates can be measured using a modified dermatology instrument. Measurements were higher and more variable with lens wear consistent with previous literature. Control of environmental conditions is important as a higher humidity results in a reduced evaporation rate. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
A Simple Model of the Accommodating Lens of the Human Eye
ERIC Educational Resources Information Center
Oommen, Vinay; Kanthakumar, Praghalathan
2014-01-01
The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…
Experimental Analysis of Desalination Unit Coupled with Solar Water Lens Concentrator
NASA Astrophysics Data System (ADS)
Chaithanya, K. K.; Rajesh, V. R.; Suresh, Rahul
2016-09-01
The main problem that the world faces in this scenario is shortage of potable water. Hence this research work rivets to increase the yield of desalination system in an economical way. The integration of solar concentrator and desalination unit can project the desired yield, but the commercially available concentrated solar power technologies (CSP) are not economically viable. So this study proposes a novel method to concentrate ample amount of solar radiation in a cost effective way. Water acting as lens is a highlighted technology initiated in this work, which can be a substitute for CSP systems. And water lens can accelerate the desalination process so as to increase the yield economically. The solar irradiance passing through the water will be concentrated at a focal point, and the concentration depends on curvature of water lens. The experimental analysis of water lens makes use of transparent thin sheet, supported on a metallic structure. The Plano convex shape of water lens is developed by varying the volume of water that is being poured on the transparent thin sheet. From the experimental analysis it is inferred that, as the curvature of water lens increases, solar irradiance can be focused more accurately on to the focus and a higher water temperature is obtained inside the solar still.
A 5mm catheter for constant resolution probing in Fourier domain optical coherence endoscopy
NASA Astrophysics Data System (ADS)
Lee, Kye-Sung; Wu, Lei; Xie, Huikai; Ilegbusi, Olusegun; Costa, Marco; Rolland, Jannick P.
2007-02-01
A 5mm biophotonic catheter was conceived for optical coherence tomography (OCT) with collimation optics, an axicon lens, and custom design imaging optics, yielding a 360 degree scan aimed at imaging within concave structures such as lung lobes. In OCT a large depth of focus is necessary to image a thick sample with a constant high transverse resolution. There are two approaches to achieving constant lateral resolution in OCT: Dynamic focusing or Bessel beam forming. This paper focuses on imaging with Bessel beams. A Bessel beam can be generated in the sample arm of the OCT interferometer when axicon optics is employed instead of a conventional focusing lens. We present a design for a 5mm catheter that combines an axicon lens with imaging optics and the coupling of a MEMS mirror attached to a micromotor that allow 360 degree scanning with a resolution of about 5 microns across a depth of focus of about 1.2mm.
Accommodation, refractive error and eye growth in chickens.
Schaeffel, F; Glasser, A; Howland, H C
1988-01-01
We raised chickens with defocusing lenses of differing powers in front of their eyes. For this purpose, small hoods made from soft, thin leather were carefully fitted to their heads. Lenses were attached to the hoods by velcro fasteners and could be easily removed for cleaning. The powers of the lenses were such that their optical effects could be compensated for by accommodation. It was verified by infrared (IR) photoretinoscopy that the chickens could keep their retinal images in focus. Wearing a lens resulted in a consistent shift of the non cycloplegic refractive state (measured without the lens) which was in the direction to compensate for the lens. We used a sensitive technique (precision = +/- 50 micron as estimated from the variability of repeated measurements) to measure the posterior nodal distance (PND) in excised eyes of birds grown with lenses. The PND, in turn, was used to compare eyes treated with different lenses. It was found that the PND was increased in eyes which were treated with negative lenses compared to those treated with positive lenses. This effect occurs independently in both eyes and it is not due to changes in corneal curvature. We discuss our result in terms of a closed-loop feedback system for the regulation of eye growth.
Optical switch based on electrowetting liquid lens
NASA Astrophysics Data System (ADS)
Li, Lei; Liu, Chao; Peng, Hua-Rong; Wang, Qiong-Hua
2012-05-01
In this paper, we propose an optical switch based on an electrowetting liquid lens. The device consists of an electrowetting liquid lens and a non-transparent cap with a pin hole. When the lens is actuated to be positive, the incident light can be converged on the pin hole and pass through the hole with less attenuation. When the lens is deformed to be negative, the incident light is diverged and most of light is blocked by the cap. Our results show that the system can provide high contrast ratio (˜800:1) and reasonable response time (˜88 ms). The proposed optical switch has potential application in light shutters, variable optical attenuators, and adaptive irises.
Smart optical writing head design for laser-based manufacturing
NASA Astrophysics Data System (ADS)
Amin, M. Junaid; Riza, Nabeel A.
2014-03-01
Proposed is a smart optical writing head design suitable for high precision industrial laser based machining and manufacturing applications. The design uses an Electronically Controlled Variable Focus Lens (ECVFL) which enables the highest achievable spatial resolution of writing head spot sizes for axial target distances reaching 8 meters. A proof-of-concept experiment is conducted using a visible wavelength laser with a collimated beam that is coupled to beam conditioning optics which includes an electromagnetically actuated deformable membrane liquid ECVFL cascaded with a bias convex lens of fixed focal length. Electronic tuning and control of the ECVFL keeps the laser writing head far-field spot beam radii under 1 mm that is demonstrated over a target range of 20 cm to 800 cm. Applications for the proposed writing head design, which can accommodate both continuous wave and pulsed wave sources, include laser machining, high precision industrial molding of components, as well as materials processing requiring material sensitive optical power density control.
Miniature hybrid optical imaging lens
Sitter, Jr., David N.; Simpson, Marc L.
1997-01-01
A miniature lens system that corrects for imaging and chromatic aberrations, the lens system being fabricated from primarily commercially-available components. A first element at the input to a lens housing is an aperture stop. A second optical element is a refractive element with a diffractive element closely coupled to, or formed a part of, the rear surface of the refractive element. Spaced closely to the diffractive element is a baffle to limit the area of the image, and this is closely followed by a second refractive lens element to provide the final correction. The image, corrected for aberrations exits the last lens element to impinge upon a detector plane were is positioned any desired detector array. The diffractive element is fabricated according to an equation that includes, as variables, the design wavelength, the index of refraction and the radius from an optical axis of the lens system components.
Miniature hybrid optical imaging lens
Sitter, D.N. Jr.; Simpson, M.L.
1997-10-21
A miniature lens system that corrects for imaging and chromatic aberrations is disclosed, the lens system being fabricated from primarily commercially-available components. A first element at the input to a lens housing is an aperture stop. A second optical element is a refractive element with a diffractive element closely coupled to, or formed a part of, the rear surface of the refractive element. Spaced closely to the diffractive element is a baffle to limit the area of the image, and this is closely followed by a second refractive lens element to provide the final correction. The image, corrected for aberrations exits the last lens element to impinge upon a detector plane were is positioned any desired detector array. The diffractive element is fabricated according to an equation that includes, as variables, the design wavelength, the index of refraction and the radius from an optical axis of the lens system components. 2 figs.
Guillaume, Yves R F; Dawson, Jeremy F; Otaye-Ebede, Lilian; Woods, Stephen A; West, Michael A
2017-02-01
To account for the double-edged nature of demographic workplace diversity (i.e,. relational demography, work group diversity, and organizational diversity) effects on social integration, performance, and well-being-related variables, research has moved away from simple main effect approaches and started examining variables that moderate these effects. While there is no shortage of primary studies of the conditions under which diversity leads to positive or negative outcomes, it remains unclear which contingency factors make it work. Using the Categorization-Elaboration Model as our theoretical lens, we review variables moderating the effects of workplace diversity on social integration, performance, and well-being outcomes, focusing on factors that organizations and managers have control over (i.e., strategy, unit design, human resource, leadership, climate/culture, and individual differences). We point out avenues for future research and conclude with practical implications. © 2015 The Authors. Journal of Organizational Behavior published by John Wiley & Sons, Ltd.
Dawson, Jeremy F.; Otaye‐Ebede, Lilian; Woods, Stephen A.; West, Michael A.
2015-01-01
Summary To account for the double‐edged nature of demographic workplace diversity (i.e,. relational demography, work group diversity, and organizational diversity) effects on social integration, performance, and well‐being‐related variables, research has moved away from simple main effect approaches and started examining variables that moderate these effects. While there is no shortage of primary studies of the conditions under which diversity leads to positive or negative outcomes, it remains unclear which contingency factors make it work. Using the Categorization‐Elaboration Model as our theoretical lens, we review variables moderating the effects of workplace diversity on social integration, performance, and well‐being outcomes, focusing on factors that organizations and managers have control over (i.e., strategy, unit design, human resource, leadership, climate/culture, and individual differences). We point out avenues for future research and conclude with practical implications. © 2015 The Authors. Journal of Organizational Behavior published by John Wiley & Sons, Ltd PMID:28239234
Effect of dual-focus soft contact lens wear on axial myopia progression in children.
Anstice, Nicola S; Phillips, John R
2011-06-01
To test the efficacy of an experimental Dual-Focus (DF) soft contact lens in reducing myopia progression. Prospective, randomized, paired-eye control, investigator-masked trial with cross-over. Forty children, 11-14 years old, with mean spherical equivalent refraction (SER) of -2.71 ± 1.10 diopters (D). Dual-Focus lenses had a central zone that corrected refractive error and concentric treatment zones that created 2.00 D of simultaneous myopic retinal defocus during distance and near viewing. Control was a single vision distance (SVD) lens with the same parameters but without treatment zones. Children wore a DF lens in 1 randomly assigned eye and an SVD lens in the fellow eye for 10 months (period 1). Lens assignment was then swapped between eyes, and lenses were worn for a further 10 months (period 2). Primary outcome was change in SER measured by cycloplegic autorefraction over 10 months. Secondary outcome was a change in axial eye length (AXL) measured by partial coherence interferometry over 10 months. Accommodation wearing DF lenses was assessed using an open-field autorefractor. In period 1, the mean change in SER with DF lenses (-0.44 ± 0.33 D) was less than with SVD lenses (-0.69 ± 0.38 D; P < 0.001); mean increase in AXL was also less with DF lenses (0.11 ± 0.09 mm) than with SVD lenses (0.22 ± 0.10 mm; P < 0.001). In 70% of the children, myopia progression was reduced by 30% or more in the eye wearing the DF lens relative to that wearing the SVD lens. Similar reductions in myopia progression and axial eye elongation were also observed with DF lens wear during period 2. Visual acuity and contrast sensitivity with DF lenses were not significantly different than with SVD lenses. Accommodation to a target at 40 cm was driven through the central distance-correction zone of the DF lens. Dual-Focus lenses provided normal acuity and contrast sensitivity and allowed accommodation to near targets. Myopia progression and eye elongation were reduced significantly in eyes wearing DF lenses. The data suggest that sustained myopic defocus, even when presented to the retina simultaneously with a clear image, can act to slow myopia progression without compromising visual function. Proprietary or commercial disclosure may be found after the references. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Foil focusing of relativistic electron beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekdahl, Jr., Carl August
2017-10-26
When an intense relativistic electron beams (IREB) passes through a grounded metal foil, the transverse electric field due to the beam space charge is locally shorted out, and the beam is focused by the magnetic field of its current. The effect can be treated as focusing by a thin lens with first order aberration. Expressions for the focal length and aberration coefficient of the equivalent thin lens are developed in this note. These are then applied to practical examples representative of IREB research at Los Alamos National Laboratory.
Ultrafast Beam Filamentation: Spatio-Temporal Characterization and Control
2013-11-01
measurement of spectral phase[7]. The output of the laser passes through a BK7 plate set at a Brewster angle to clean up the polarization of the beam...at the focus of a lens . In this configuration, the pulse focuses temporally and spatially at the same time. We developed a theory for understanding...focus by shaping only the spatial phase of the starting beam. Finally, we showed for the first time that Kerr- lens modelocking can be achieved in a Ti
Method of forming aperture plate for electron microscope
NASA Technical Reports Server (NTRS)
Heinemann, K. (Inventor)
1974-01-01
An electron microscope is described with an electron source a condenser lens having either a circular aperture for focusing a solid cone of electrons onto a specimen or an annular aperture for focusing a hollow cone of electrons onto the specimen. It also has objective lens with an annular objective aperture, for focusing electrons passing through the specimen onto an image plane. A method of making the annular objective aperture using electron imaging, electrolytic deposition and ion etching techniques is included.
MedlinePlus Videos and Cool Tools
... lens. The light is then refracted a second time while passing through the lens, finally focusing on the retina. The retina is the light sensitive part of the eye. Impulses travel down the optic nerve to the occipital lobe ...
Demonstration of passive plasma lensing of a laser wakefield accelerated electron bunch
Kuschel, S.; Hollatz, D.; Heinemann, T.; ...
2016-07-20
We report on the first demonstration of passive all-optical plasma lensing using a two-stage setup. An intense femtosecond laser accelerates electrons in a laser wakefield accelerator (LWFA) to 100 MeV over millimeter length scales. By adding a second gas target behind the initial LWFA stage we introduce a robust and independently tunable plasma lens. We observe a density dependent reduction of the LWFA electron beam divergence from an initial value of 2.3 mrad, down to 1.4 mrad (rms), when the plasma lens is in operation. Such a plasma lens provides a simple and compact approach for divergence reduction well matchedmore » to the mm-scale length of the LWFA accelerator. The focusing forces are provided solely by the plasma and driven by the bunch itself only, making this a highly useful and conceptually new approach to electron beam focusing. Possible applications of this lens are not limited to laser plasma accelerators. Since no active driver is needed the passive plasma lens is also suited for high repetition rate focusing of electron bunches. As a result, its understanding is also required for modeling the evolution of the driving particle bunch in particle driven wake field acceleration.« less
Super-resolved all-refocused image with a plenoptic camera
NASA Astrophysics Data System (ADS)
Wang, Xiang; Li, Lin; Hou, Guangqi
2015-12-01
This paper proposes an approach to produce the super-resolution all-refocused images with the plenoptic camera. The plenoptic camera can be produced by putting a micro-lens array between the lens and the sensor in a conventional camera. This kind of camera captures both the angular and spatial information of the scene in one single shot. A sequence of digital refocused images, which are refocused at different depth, can be produced after processing the 4D light field captured by the plenoptic camera. The number of the pixels in the refocused image is the same as that of the micro-lens in the micro-lens array. Limited number of the micro-lens will result in poor low resolution refocused images. Therefore, not enough details will exist in these images. Such lost details, which are often high frequency information, are important for the in-focus part in the refocused image. We decide to super-resolve these in-focus parts. The result of image segmentation method based on random walks, which works on the depth map produced from the 4D light field data, is used to separate the foreground and background in the refocused image. And focusing evaluation function is employed to determine which refocused image owns the clearest foreground part and which one owns the clearest background part. Subsequently, we employ single image super-resolution method based on sparse signal representation to process the focusing parts in these selected refocused images. Eventually, we can obtain the super-resolved all-focus image through merging the focusing background part and the focusing foreground part in the way of digital signal processing. And more spatial details will be kept in these output images. Our method will enhance the resolution of the refocused image, and just the refocused images owning the clearest foreground and background need to be super-resolved.
Method and apparatus for sputtering with a plasma lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anders, Andre
A plasma lens for enhancing the quality and rate of sputter deposition onto a substrate is described herein. The plasma lens serves to focus positively charged ions onto the substrate while deflecting negatively charged ions, while at the same time due to the line of sight positioning of the lens, allowing for free passage of neutrals from the target to the substrate. The lens itself is formed of a wound coil of multiple turns, inside of which are deposed spaced lens electrodes which are electrically paired to impress an E field overtop the B field generated by the coil, themore » potential applied to the electrodes increasing from end to end towards the center of the lens, where the applied voltage is set to a high potential at the center electrodes as to produce a potential minimum on the axis of the lens.« less
Plasma Lens for Muon and Neutrino Beams
NASA Astrophysics Data System (ADS)
Kahn, Stephen; Korenev, Sergey; Bishai, Mary; Diwan, Milind; Gallardo, Juan; Hershcovitch, Ady; Johnson, Brant
2008-04-01
The plasma lens is examined as an alternate to focusing horns and solenoids for use in a neutrino or muon beam facility. The plasma lens concept is based on a combined high-current lens/target configuration. The current is fed at electrodes located upstream and downstream from the target where pion capturing is needed. The current flows primarily in the plasma, which has a lower resistivity than the target. A second plasma lens section, with an additional current feed, follows the target to provide shaping of the plasma stability. The geometry of the plasma is shaped to provide optimal pion capture. Simulations of this plasma lens system have shown a 25% higher neutrino production than the horn system. A plasma lens has additional advantage: larger axial current than horns, minimal neutrino contamination during antineutrino running, and negligible pion absorption or scattering. Results from particle simulations using a plasma lens will be presented.
Smart lens: tunable liquid lens for laser tracking
NASA Astrophysics Data System (ADS)
Lin, Fan-Yi; Chu, Li-Yu; Juan, Yu-Shan; Pan, Sih-Ting; Fan, Shih-Kang
2007-05-01
A tracking system utilizing tunable liquid lens is proposed and demonstrated. Adapting the concept of EWOD (electrowetting-on-dielectric), the curvature of a droplet on a dielectric film can be controlled by varying the applied voltage. When utilizing the droplet as an optical lens, the focal length of this adaptive liquid lens can be adjusted as desired. Moreover, the light that passes through it can therefore be focused to different positions in space. In this paper, the tuning range of the curvature and focal length of the tunable liquid lens is investigated. Droplet transformation is observed and analyzed under a CCD camera. A tracking system combining the tunable liquid lens with a laser detection system is also proposed. With a feedback circuit that maximizing the returned signal by controlling the tunable lens, the laser beam can keep tracked on a distant reflected target while it is moving.
A Stochastic Model of Eye Lens Growth
Šikić, Hrvoje; Shi, Yanrong; Lubura, Snježana; Bassnett, Steven
2015-01-01
The size and shape of the ocular lens must be controlled with precision if light is to be focused sharply on the retina. The lifelong growth of the lens depends on the production of cells in the anterior epithelium. At the lens equator, epithelial cells differentiate into fiber cells, which are added to the surface of the existing fiber cell mass, increasing its volume and area. We developed a stochastic model relating the rates of cell proliferation and death in various regions of the lens epithelium to deposition of fiber cells and lens growth. Epithelial population dynamics were modeled as a branching process with emigration and immigration between various proliferative zones. Numerical simulations were in agreement with empirical measurements and demonstrated that, operating within the strict confines of lens geometry, a stochastic growth engine can produce the smooth and precise growth necessary for lens function. PMID:25816743
Shafie, Suraiya M.; Barria von-Bischhoffshausen, Fernando R.; Bateman, J. Bronwyn
2006-01-01
PURPOSE To document intrafamilial and interocular phenotypic variability of autosomal dominant cataract (ADC). DESIGN Prospective observational case series. METHODS We performed ophthalmologic examination in four Chilean ADC families. RESULTS The families exhibited variability with respect to morphology, location with the lens, color and density of cataracts among affected members. We documented asymmetry between eyes in the morphology, location within the lens, color and density of cataracts, and a variable rate of progression. CONCLUSIONS The cataracts in these families exhibit wide intrafamilial and interocular phenotypic variability, supporting the premise that the mutated genes are expressed differentially in individuals and between eyes; other genes or environmental factors may be the bases for this variability. Marked progression among some family members underscores the variable clinical course of a common mutation within a family. Like retinitis pigmentosa, classification of ADC will be most useful if based on the gene and specific mutation. PMID:16564818
Focusing elliptical laser beams
NASA Astrophysics Data System (ADS)
Marchant, A. B.
1984-03-01
The spot formed by focusing an elliptical laser beam through an ordinary objective lens can be optimized by properly filling the objective lens. Criteria are given for maximizing the central irradiance and the line-spread function. An optimized spot is much less elliptical than the incident laser beam. For beam ellipticities as high as 2:1, this spatial filtering reduces the central irradiance by less than 14 percent.
Contact lens overrefraction variability in corneal power estimation after refractive surgery.
Joslin, Charlotte E; Koster, James; Tu, Elmer Y
2005-12-01
To evaluate the accuracy and precision of the contact lens overrefraction (CLO) method in determining corneal refractive power in post-refractive-surgery eyes. Refractive Surgery Service and Contact Lens Service, University of Illinois, Chicago, Illinois, USA. Fourteen eyes of 7 subjects who had a single myopic laser in situ keratomileusis procedure within 12 months with refractive stability were included in this prospective case series. The CLO method was compared with the historical method of predicting the corneal power using 4 different lens fitting strategies and 3 refractive pupil scan sizes (3 mm, 5 mm, and total pupil). Rigid lenses included 3 9.0 mm overall diameter lenses fit flat, steep, and an average of the 2, and a 15.0 mm diameter lens steep fit. Cycloplegic CLO was performed using the autorefractor function of the Nidek OPD-Scan ARK-10000. Results with each strategy were compared with the corneal power estimated with the historical method. The bias (mean of the difference), 95% limits of agreement, and difference versus mean plots for each strategy are presented. In each subject, the CLO-estimated corneal power varied based on lens fit. On average, the bias between CLO and historical methods ranged from -0.38 to +2.42 diopters (D) and was significantly different from 0 in all but 3 strategies. Substantial variability in precision existed between fitting strategies, with the range of the 95% limits of agreement approximating 0.50 D in 2 strategies and 2.59 D in the worst-case scenario. The least precise fitting strategy was use of flat-fitting 9.0 mm diameter lenses. The accuracy and precision of the CLO method of estimating corneal power in post-refractive-surgery eyes was highly variable on the basis of how rigid lense were fit. One of the most commonly used fitting strategies in clinical practice--flat-fitting a 9.0 diameter lens-resulted in the poorest accuracy and precision. Results also suggest use of large-diameter lenses may improve outcomes.
Modularization of gradient-index optical design using wavefront matching enabled optimization.
Nagar, Jogender; Brocker, Donovan E; Campbell, Sawyer D; Easum, John A; Werner, Douglas H
2016-05-02
This paper proposes a new design paradigm which allows for a modular approach to replacing a homogeneous optical lens system with a higher-performance GRadient-INdex (GRIN) lens system using a WaveFront Matching (WFM) method. In multi-lens GRIN systems, a full-system-optimization approach can be challenging due to the large number of design variables. The proposed WFM design paradigm enables optimization of each component independently by explicitly matching the WaveFront Error (WFE) of the original homogeneous component at the exit pupil, resulting in an efficient design procedure for complex multi-lens systems.
Development of adaptive liquid microlenses and microlens arrays
NASA Astrophysics Data System (ADS)
Berry, Shaun R.; Stewart, Jason B.; Thorsen, Todd A.; Guha, Ingrid
2013-03-01
We report on the development of sub-millimeter size adaptive liquid microlenses and microlens arrays using two immiscible liquids to form individual lenses. Microlenses and microlens arrays having aperture diameters as small as 50 microns were fabricated on a planar quartz substrate using patterned hydrophobic/hydrophilic regions. Liquid lenses were formed by a self-assembled oil dosing process that created well-defined lenses having a high fill factor. Variable focus was achieved by controlling the lens curvature through electrowetting. Greater than 70° of contact angle change was achieved with less than 20 volts, which results in a large optical power dynamic range.
Improving the lens design and performance of a contemporary electromagnetic shock wave lithotripter
Neisius, Andreas; Smith, Nathan B.; Sankin, Georgy; Kuntz, Nicholas John; Madden, John Francis; Fovargue, Daniel E.; Mitran, Sorin; Lipkin, Michael Eric; Simmons, Walter Neal; Preminger, Glenn M.; Zhong, Pei
2014-01-01
The efficiency of shock wave lithotripsy (SWL), a noninvasive first-line therapy for millions of nephrolithiasis patients, has not improved substantially in the past two decades, especially in regard to stone clearance. Here, we report a new acoustic lens design for a contemporary electromagnetic (EM) shock wave lithotripter, based on recently acquired knowledge of the key lithotripter field characteristics that correlate with efficient and safe SWL. The new lens design addresses concomitantly three fundamental drawbacks in EM lithotripters, namely, narrow focal width, nonidealized pulse profile, and significant misalignment in acoustic focus and cavitation activities with the target stone at high output settings. Key design features and performance of the new lens were evaluated using model calculations and experimental measurements against the original lens under comparable acoustic pulse energy (E+) of 40 mJ. The −6-dB focal width of the new lens was enhanced from 7.4 to 11 mm at this energy level, and peak pressure (41 MPa) and maximum cavitation activity were both realigned to be within 5 mm of the lithotripter focus. Stone comminution produced by the new lens was either statistically improved or similar to that of the original lens under various in vitro test conditions and was significantly improved in vivo in a swine model (89% vs. 54%, P = 0.01), and tissue injury was minimal using a clinical treatment protocol. The general principle and associated techniques described in this work can be applied to design improvement of all EM lithotripters. PMID:24639497
Improving the lens design and performance of a contemporary electromagnetic shock wave lithotripter.
Neisius, Andreas; Smith, Nathan B; Sankin, Georgy; Kuntz, Nicholas John; Madden, John Francis; Fovargue, Daniel E; Mitran, Sorin; Lipkin, Michael Eric; Simmons, Walter Neal; Preminger, Glenn M; Zhong, Pei
2014-04-01
The efficiency of shock wave lithotripsy (SWL), a noninvasive first-line therapy for millions of nephrolithiasis patients, has not improved substantially in the past two decades, especially in regard to stone clearance. Here, we report a new acoustic lens design for a contemporary electromagnetic (EM) shock wave lithotripter, based on recently acquired knowledge of the key lithotripter field characteristics that correlate with efficient and safe SWL. The new lens design addresses concomitantly three fundamental drawbacks in EM lithotripters, namely, narrow focal width, nonidealized pulse profile, and significant misalignment in acoustic focus and cavitation activities with the target stone at high output settings. Key design features and performance of the new lens were evaluated using model calculations and experimental measurements against the original lens under comparable acoustic pulse energy (E+) of 40 mJ. The -6-dB focal width of the new lens was enhanced from 7.4 to 11 mm at this energy level, and peak pressure (41 MPa) and maximum cavitation activity were both realigned to be within 5 mm of the lithotripter focus. Stone comminution produced by the new lens was either statistically improved or similar to that of the original lens under various in vitro test conditions and was significantly improved in vivo in a swine model (89% vs. 54%, P = 0.01), and tissue injury was minimal using a clinical treatment protocol. The general principle and associated techniques described in this work can be applied to design improvement of all EM lithotripters.
Design and research of focusable secondary microprism in concentrating photovoltaic module
NASA Astrophysics Data System (ADS)
Guo, Limin; Liu, Youqiang; Zhao, Guoming; Wang, Zhiyong
2017-09-01
Low tracking accuracy of tracker, wind induced vibration of structure and lens deformation by temperature lead to non-vertical incident irradiation to the Fresnel lens, which necessitates a secondary concentrator in actual engineering application of concentrating photovoltaic module. This paper adds a secondary focusable microprism between Fresnel lens and solar cells in order to improve optical efficiency. The 3D model of microprism is established by SOLIDWORDS and main parameters are optimized using ZEMAX. Results show that combination of Fresnel lens and focusable microprism achieves a higher energy when the secondary microprism upper spherical diameter is 18mm, the opposite side face included angle is 116°, and the side length of the bottom is 2.15mm. The highest energy of solar cell surface can reach 2.4998W, improving 33.2%, and the module height with the secondary microprism is 88mm, which reduces by 5.5mm without secondary microprism. Experimental results show that the optical efficiency of 400X concentrating module system is 88.67%, the acceptance angle is ±1.2°, the 400X module maximum output power is 144.7W.
Fovargue, Daniel E; Mitran, Sorin; Smith, Nathan B; Sankin, Georgy N; Simmons, Walter N; Zhong, Pei
2013-08-01
A multiphysics computational model of the focusing of an acoustic pulse and subsequent shock wave formation that occurs during extracorporeal shock wave lithotripsy is presented. In the electromagnetic lithotripter modeled in this work the focusing is achieved via a polystyrene acoustic lens. The transition of the acoustic pulse through the solid lens is modeled by the linear elasticity equations and the subsequent shock wave formation in water is modeled by the Euler equations with a Tait equation of state. Both sets of equations are solved simultaneously in subsets of a single computational domain within the BEARCLAW framework which uses a finite-volume Riemann solver approach. This model is first validated against experimental measurements with a standard (or original) lens design. The model is then used to successfully predict the effects of a lens modification in the form of an annular ring cut. A second model which includes a kidney stone simulant in the domain is also presented. Within the stone the linear elasticity equations incorporate a simple damage model.
Fovargue, Daniel E.; Mitran, Sorin; Smith, Nathan B.; Sankin, Georgy N.; Simmons, Walter N.; Zhong, Pei
2013-01-01
A multiphysics computational model of the focusing of an acoustic pulse and subsequent shock wave formation that occurs during extracorporeal shock wave lithotripsy is presented. In the electromagnetic lithotripter modeled in this work the focusing is achieved via a polystyrene acoustic lens. The transition of the acoustic pulse through the solid lens is modeled by the linear elasticity equations and the subsequent shock wave formation in water is modeled by the Euler equations with a Tait equation of state. Both sets of equations are solved simultaneously in subsets of a single computational domain within the BEARCLAW framework which uses a finite-volume Riemann solver approach. This model is first validated against experimental measurements with a standard (or original) lens design. The model is then used to successfully predict the effects of a lens modification in the form of an annular ring cut. A second model which includes a kidney stone simulant in the domain is also presented. Within the stone the linear elasticity equations incorporate a simple damage model. PMID:23927200
NASA Technical Reports Server (NTRS)
Bernacki, Bruce E.; Mansuripur, M.
1992-01-01
A commonly used tracking method on pre-grooved magneto-optical (MO) media is the push-pull technique, and the astigmatic method is a popular focus-error detection approach. These two methods are analyzed using DIFFRACT, a general-purpose scalar diffraction modeling program, to observe the effects on the error signals due to focusing lens misalignment, Seidel aberrations, and optical crosstalk (feedthrough) between the focusing and tracking servos. Using the results of the astigmatic/push-pull system as a basis for comparison, a novel focus/track-error detection technique that utilizes a ring toric lens is evaluated as well as the obscuration method (focus error detection only).
Microwave focusing with uniaxially symmetric gradient index metamaterials
NASA Astrophysics Data System (ADS)
Wheeland, Sara; Sternberg, Oren; Perez, Israel; Rockway, John D.
2016-09-01
Previous efforts to create a metamaterial lens in the microwave X band frequency range focused on the development of a device with biaxial symmetry. This allows for focusing solely along the central axis of propagation. For applications involving wave direction or energy diversion, focusing may be required off the central axis. This work explores a metamaterial device with uniaxial symmetry, namely in the direction of propagation. Ray-trace optimization and full-wave finite element simulations contribute to the design of the lens. By changing the placement of the focus, we achieve further control of the focus parameters. While the present work uses coils, the unit cell can consist of any structure or material.
Evaluate depth of field limits of fixed focus lens arrangements in thermal infrared
NASA Astrophysics Data System (ADS)
Schuster, Norbert
2016-05-01
More and more modern thermal imaging systems use uncooled detectors. High volume applications work with detectors that have a reduced pixel count (typically between 200x150 and 640x480). This reduces the usefulness of modern image treatment procedures such as wave front coding. On the other hand, uncooled detectors demand lenses with fast fnumbers, near f/1.0, which reduces the expected Depth of Field (DoF). What are the limits on resolution if the target changes distance to the camera system? The desire to implement lens arrangements without a focusing mechanism demands a deeper quantification of the DoF problem. A new approach avoids the classic "accepted image blur circle" and quantifies the expected DoF by the Through Focus MTF of the lens. This function is defined for a certain spatial frequency that provides a straightforward relation to the pixel pitch of imaging device. A certain minimum MTF-level is necessary so that the complete thermal imaging system can realize its basic functions, such as recognition or detection of specified targets. Very often, this technical tradeoff is approved with a certain lens. But what is the impact of changing the lens for one with a different focal length? Narrow field lenses, which give more details of targets in longer distances, tighten the DoF problem. A first orientation is given by the hyperfocal distance. It depends in a square relation on the focal length and in a linear relation on the through focus MTF of the lens. The analysis of these relations shows the contradicting requirements between higher thermal and spatial resolution, faster f-number and desired DoF. Furthermore, the hyperfocal distance defines the DoF-borders. Their relation between is such as the first order imaging formulas. A calculation methodology will be presented to transfer DoF-results from an approved combination lens and camera to another lens in combination with the initial camera. Necessary input for this prediction is the accepted DoF of the initial combination and the through focus MTFs of both lenses. The accepted DoF of the initial combination defines an application and camera related MTF-level, which must be provided also by the new lens. Examples are provided. The formula of the Diffraction-Limited-Through-Focus-MTF (DLTF) quantifies the physical limit and works without any ray trace. This relation respects the pixel pitch, the waveband and the aperture based f-number, but is independent of detector size. The DLTF has a steeper slope than the ray traced Through-Focus-MTF; its maximum is the diffraction limit. The DLTF predicts the DoF-relations quite precisely. Differences to ray trace results are discussed. Last calculations with modern detectors show that a static chosen MTF-level doesn't reflect the reality for the DoFproblem. The MTF-level to respect depends on application, pixel pitch, IR-camera and image treatment. A value of 0.250 at the detector Nyquist frequency seems to be a reasonable starting point for uncooled FPAs with 17μm pixel pitch.
Light absorption cell combining variable path and length pump
Prather, William S.
1993-01-01
A device for use in making spectrophotometric measurements of fluid samples. In particular, the device is a measurement cell containing a movable and a fixed lens with a sample of the fluid therebetween and through which light shines. The cell is connected to a source of light and a spectrophotometer via optic fibers. Movement of the lens varies the path length and also pumps the fluid into and out of the cell. Unidirectional inlet and exit valves cooperate with the movable lens to assure a one-way flow of fluid through the cell. A linear stepper motor controls the movement of the lens and cycles it from a first position closer to the fixed lens and a second position farther from the fixed lens, preferably at least 10 times per minute for a nearly continuous stream of absorption spectrum data.
Maimbourg, Guillaume; Houdouin, Alexandre; Deffieux, Thomas; Tanter, Mickael; Aubry, Jean-François
2018-01-16
The development of multi-element arrays for better control of the shape of ultrasonic beams has opened the way for focusing through highly aberrating media, such as the human skull. As a result, the use of brain therapy with transcranial-focused ultrasound has rapidly grown. Although effective, such technology is expensive. We propose a disruptive, low-cost approach that consists of focusing a 1 MHz ultrasound beam through a human skull with a single-element transducer coupled with a tailored silicone acoustic lens cast in a 3D-printed mold and designed using computed tomography-based numerical acoustic simulation. We demonstrate on N = 3 human skulls that adding lens-based aberration correction to a single-element transducer increases the deposited energy on the target 10 fold.
NASA Astrophysics Data System (ADS)
Maimbourg, Guillaume; Houdouin, Alexandre; Deffieux, Thomas; Tanter, Mickael; Aubry, Jean-François
2018-01-01
The development of multi-element arrays for better control of the shape of ultrasonic beams has opened the way for focusing through highly aberrating media, such as the human skull. As a result, the use of brain therapy with transcranial-focused ultrasound has rapidly grown. Although effective, such technology is expensive. We propose a disruptive, low-cost approach that consists of focusing a 1 MHz ultrasound beam through a human skull with a single-element transducer coupled with a tailored silicone acoustic lens cast in a 3D-printed mold and designed using computed tomography-based numerical acoustic simulation. We demonstrate on N = 3 human skulls that adding lens-based aberration correction to a single-element transducer increases the deposited energy on the target 10 fold.
Method and apparatus for a multibeam beacon laser assembly for optical communications
NASA Technical Reports Server (NTRS)
Biswas, Abhijit (Inventor); Sanji, Babak (Inventor); Wright, Malcolm W. (Inventor); Page, Norman Alan (Inventor)
2005-01-01
An optical beacon is comprised of a telescope having a primary focal plane or Coud? focal plane, a plurality of fiber coupled laser sources for generating a plurality of beams, a collimator for collimating the plurality of beams, and optics for combining and focusing the plurality of collimated beams onto the primary or Coud? focal plane of the telescope. The telescope propagates the optical beacon, which is arranged into a ring of incoherent plurality of collimated beams. The apparatus further comprises fiber splitters coupled to each laser source to provide at least eight beams from at least four laser sources. The optics comprises a prism assembly, a combiner lens, a focusing lens and a field lens for focusing the plurality of collimated beams onto the primary focal plane or Coud? focal plane of the telescope.
Focusing hard X-rays with old LPs
NASA Astrophysics Data System (ADS)
Cederström, Björn; Cahn, Robert N.; Danielsson, Mats; Lundqvist, Mats; Nygren, David R.
2000-04-01
We have found that two sections cut from a vinyl long-playing record can form a spherical aberration-free refractive lens for hard X-rays. Our manufactured saw-tooth refractive lens has a focal length of 22 cm for 23-keV X-rays. The low cost and short focal length of this lens make it feasible for use in small-scale experiments with conventional X-ray tubes.
Non-toric extended depth of focus contact lenses for astigmatism and presbyopia correction
NASA Astrophysics Data System (ADS)
Ben Yaish, Shai; Zlotnik, Alex; Yehezkel, Oren; Lahav-Yacouel, Karen; Belkin, Michael; Zalevsky, Zeev
2010-02-01
Purpose: Testing whether the extended depth of focus technology embedded on non-toric contact lenses is a suitable treatment for both astigmatism and presbyopia. Methods: The extended depth of focus pattern consisting of microndepth concentric grooves was engraved on a surface of a mono-focal soft contact lens. These grooves create an interference pattern extending the focus from a point to a length of about 1mm providing a 3.00D extension in the depth of focus. The extension in the depth of focus provides high quality focused imaging capabilities from near through intermediate and up to far ranges. Due to the angular symmetry of the engraved pattern the extension in the depth of focus can also resolve regular as well as irregular astigmatism aberrations. Results: The contact lens was tested on a group of 8 astigmatic and 13 subjects with presbyopia. Average correction of 0.70D for astigmatism and 1.50D for presbyopia was demonstrated. Conclusions: The extended depth of focus technology in a non-toric contact lens corrects simultaneously astigmatism and presbyopia. The proposed solution is based upon interference rather than diffraction effects and thus it is characterized by high energetic efficiency to the retina plane as well as reduced chromatic aberrations.
Direct laser writing for micro-optical devices using a negative photoresist.
Tsutsumi, Naoto; Hirota, Junichi; Kinashi, Kenji; Sakai, Wataru
2017-12-11
Direct laser writing (DLW) via two-photon absorption (TPA) has attracted much attention as a new microfabrication technique because it can be applied to fabricate complex, three-dimensional (3D) microstructures. In this study, 3D microstructures and micro-optical devices of micro-lens array on the micrometer scale are fabricated using the negative photoresist SU-8 through TPA with a femtosecond laser pulse under a microscope. The effects of the irradiation conditions on linewidths, such as laser power, writing speed, and writing cycles (a number of times a line is overwritten), are investigated before the fabrication of the 3D microstructures. Various microstructures such as woodpiles, hemisphere and microstructures, 3D micro-lens and micro-lens array for micro-optical devices are fabricated. The shape of the micro-lens is evaluated using the shape analysis mode of a laser microscope to calculate the working distance of the fabricated micro-lenses. The calculated working distance corresponds well to the experimentally measured value. The focusing performance of the fabricated micro-lens is confirmed by the TPA fluorescence of an isopropyl thioxanthone (ITX) ethanol solution excited by a Ti:sapphire femtosecond laser at 800 nm. Micro-lens array (assembled 9 micro-lenses) are fabricated. Nine independent woodpile structures are simultaneously manufactured by DLW via TPA to confirm the multi-focusing ability using the fabricated micro-lens array.
Fiber bundle phase conjugate mirror
Ward, Benjamin G.
2012-05-01
An improved method and apparatus for passively conjugating the phases of a distorted wavefronts resulting from optical phase mismatch between elements of a fiber laser array are disclosed. A method for passively conjugating a distorted wavefront comprises the steps of: multiplexing a plurality of probe fibers and a bundle pump fiber in a fiber bundle array; passing the multiplexed output from the fiber bundle array through a collimating lens and into one portion of a non-linear medium; passing the output from a pump collection fiber through a focusing lens and into another portion of the non-linear medium so that the output from the pump collection fiber mixes with the multiplexed output from the fiber bundle; adjusting one or more degrees of freedom of one or more of the fiber bundle array, the collimating lens, the focusing lens, the non-linear medium, or the pump collection fiber to produce a standing wave in the non-linear medium.
Abe, Toshi; Furui, Shigeru; Sasaki, Hiroshi; Sakamoto, Yasuo; Suzuki, Shigeru; Ishitake, Tatsuya; Terasaki, Kinuyo; Kohtake, Hiroshi; Norbash, Alexander M; Behrman, Richard H; Hayabuchi, Naofumi
2013-03-01
To evaluate low-dose X-ray radiation effects on the eye by measuring the amount of light scattering in specific regions of the lens, we compared exposed subjects (interventional radiologists) with unexposed subjects (employees of medical service companies), as a pilot study. According to numerous exclusionary rules, subjects with confounding variables contributing to cataract formation were excluded. Left eye examinations were performed on 68 exposed subjects and 171 unexposed subjects. The eye examinations consisted of an initial screening examination, followed by Scheimpflug imaging of the lens using an anterior eye segment analysis system. The subjects were assessed for the quantity of light scattering intensities found in each of the six layers of the lens. Multiple stepwise regression analyses were performed with the stepwise regression for six variables: age, radiation exposure, smoking, drinking, wearing glasses and workplace. In addition, an age-matched comparison between exposed and unexposed subjects was performed. Minimal increased light scattering intensity in the posterior subcapsular region showed statistical significance. Our results indicate that occupational radiation exposure in interventional radiologists may affect the posterior subcapsular region of the lens. Since by its very nature this retrospective study had many limitations, further well-designed studies concerning minimal radiation-related lens changes should be carried out in a low-dose exposure group.
Robust design study on the wide angle lens with free distortion for mobile lens
NASA Astrophysics Data System (ADS)
Kim, Taeyoung; Yong, Liu; Xu, Qing
2017-10-01
Recently new trend applying wide angle in mobile imaging lens is attracting. Specially, customer requirements for capturing wider scene result that a field of view of lens be wider than 100deg. Introduction of retro-focus type lens in mobile imaging lens is required. However, imaging lens in mobile phone always face to many constraints such as lower total length, low F/# and higher performance. The sensitivity for fabrication may become more severe because of wide angle FOV. In this paper, we investigate an optical lens design satisfy all requirements for mobile imaging lens. In order to accomplish Low cost and small depth of optical system, we used plastic materials for all element and the productivity is considered for realization. The lateral color is minimized less than 2 pixels and optical distortion is less than 5%. Also, we divided optical system into 2 part for robust design. The compensation between 2 groups can help us to increase yield in practice. The 2 group alignment for high yield may be a promising solution for wide angle lens.
Mehta, Vikram V; Hull, Christopher C; Lawrenson, John G
2015-01-01
Refractive changes in diabetic eyes have long been reported but with equivocal results. The lens has been a more recent focus as the source of any change but it is possible that multiple sources of variation have made it difficult to demonstrate a systematic change clinically. The aim of this study was therefore to use a bovine lens model to investigate the optical changes in hyperglycaemia and when lenses are returned to normal glucose levels as would occur following commencement of treatment. Bovine eyes were obtained and their lenses excised under sterile conditions before placing them in culture medium within an incubator using standard tissue culture techniques. In the first experiment, lenses were transferred into culture medium containing 5 mm (n = 12), 15 mm (n = 12) and 30 mm (n = 12) glucose. Measurements were made of the change in back vertex focusing distance with equatorial lens diameter using the ScanTox(™) measurement system. From these measurements, the back vertex focal length and primary longitudinal spherical aberration were derived. In a second experiment, lenses maintained at 30 mm glucose (n = 7) were stepped down to 5 mm glucose to simulate starting diabetic therapy and measured in the same way. Changes over time were assessed with a linear regression model. A trend towards myopia was observed with increasing hyperglycaemia, this was not statistically significant. When lenses were stepped-down from hyperglycaemia to normal physiological levels of glucose, a hyperopic shift was observed in line with published clinical studies that again failed to reach statistical significance. High variability in the measurement on longitudinal spherical aberration prevented any significant trends being measured. Our results suggest that there are no consistent crystalline lens-induced refractive changes following exposure to hyperglycaemia for time-periods up to 5 days used in the current study. It is possible that bovine lenses are able to offset the raised osmotic pressure from high glucose levels in the short-term by a process of osmoregulation and that repeated osmotic stress or longer term exposure may be required to induce the changes in refraction that are seen clinically. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
NASA Astrophysics Data System (ADS)
Grulkowski, Ireneusz; Karnowski, Karol; Ruminski, Daniel; Wojtkowski, Maciej
2016-03-01
Availability of the long-depth-range OCT systems enables comprehensive structural imaging of the eye and extraction of biometric parameters characterizing the entire eye. Several approaches have been developed to perform OCT imaging with extended depth ranges. In particular, current SS-OCT technology seems to be suited to visualize both anterior and posterior eye in a single measurement. The aim of this study is to demonstrate integrated anterior segment and retinal SS-OCT imaging using a single instrument, in which the sample arm is equipped with the electrically tunable lens (ETL). ETL is composed of the optical liquid confined in the space by an elastic polymer membrane. The shape of the membrane, electrically controlled by a specific ring, defines the radius of curvature of the lens surface, thus it regulates the power of the lens. ETL can be also equipped with additional offset lens to adjust the tuning range of the optical power. We characterize the operation of the tunable lens using wavefront sensing. We develop the optimized optical set-up with two adaptive operational states of the ETL in order to focus the light either on the retina or on the anterior segment of the eye. We test the performance of the set-up by utilizing whole eye phantom as the object. Finally, we perform human eye in vivo imaging using the SS-OCT instrument with versatile imaging functionality that accounts for the optics of the eye and enables dynamic control of the optical beam focus.
NASA Astrophysics Data System (ADS)
Liu, Yan; Shen, Yuecheng; Ruan, Haowen; Brodie, Frank L.; Wong, Terence T. W.; Yang, Changhuei; Wang, Lihong V.
2018-01-01
Normal development of the visual system in infants relies on clear images being projected onto the retina, which can be disrupted by lens opacity caused by congenital cataract. This disruption, if uncorrected in early life, results in amblyopia (permanently decreased vision even after removal of the cataract). Doctors are able to prevent amblyopia by removing the cataract during the first several weeks of life, but this surgery risks a host of complications, which can be equally visually disabling. Here, we investigated the feasibility of focusing light noninvasively through highly scattering cataractous lenses to stimulate the retina, thereby preventing amblyopia. This approach would allow the cataractous lens removal surgery to be delayed and hence greatly reduce the risk of complications from early surgery. Employing a wavefront shaping technique named time-reversed ultrasonically encoded optical focusing in reflection mode, we focused 532-nm light through a highly scattering ex vivo adult human cataractous lens. This work demonstrates a potential clinical application of wavefront shaping techniques.
Apparatus for direct-to-digital spatially-heterodyned holography
Thomas, Clarence E.; Hanson, Gregory R.
2006-12-12
An apparatus operable to record a spatially low-frequency heterodyne hologram including spatially heterodyne fringes for Fourier analysis includes: a laser; a beamsplitter optically coupled to the laser; an object optically coupled to the beamsplitter; a focusing lens optically coupled to both the beamsplitter and the object; a digital recorder optically coupled to the focusing lens; and a computer that performs a Fourier transform, applies a digital filter, and performs an inverse Fourier transform. A reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form a spatially low-frequency heterodyne hologram including spatially heterodyne fringes for Fourier analysis which is recorded by the digital recorder, and the computer transforms the recorded spatially low-frequency heterodyne hologram including spatially heterodyne fringes and shifts axes in Fourier space to sit on top of a heterodyne carrier frequency defined by an angle between the reference beam and the object beam and cuts off signals around an original origin before performing the inverse Fourier transform.
Chaffee, Blake R.; Shang, Fu; Chang, Min-Lee; Clement, Tracy M.; Eddy, Edward M.; Wagner, Brad D.; Nakahara, Masaki; Nagata, Shigekazu; Robinson, Michael L.; Taylor, Allen
2014-01-01
Lens epithelial cells and early lens fiber cells contain the typical complement of intracellular organelles. However, as lens fiber cells mature they must destroy their organelles, including nuclei, in a process that has remained enigmatic for over a century, but which is crucial for the formation of the organelle-free zone in the center of the lens that assures clarity and function to transmit light. Nuclear degradation in lens fiber cells requires the nuclease DNase IIβ (DLAD) but the mechanism by which DLAD gains access to nuclear DNA remains unknown. In eukaryotic cells, cyclin-dependent kinase 1 (CDK1), in combination with either activator cyclins A or B, stimulates mitotic entry, in part, by phosphorylating the nuclear lamin proteins leading to the disassembly of the nuclear lamina and subsequent nuclear envelope breakdown. Although most post-mitotic cells lack CDK1 and cyclins, lens fiber cells maintain these proteins. Here, we show that loss of CDK1 from the lens inhibited the phosphorylation of nuclear lamins A and C, prevented the entry of DLAD into the nucleus, and resulted in abnormal retention of nuclei. In the presence of CDK1, a single focus of the phosphonuclear mitotic apparatus is observed, but it is not focused in CDK1-deficient lenses. CDK1 deficiency inhibited mitosis, but did not prevent DNA replication, resulting in an overall reduction of lens epithelial cells, with the remaining cells possessing an abnormally large nucleus. These observations suggest that CDK1-dependent phosphorylations required for the initiation of nuclear membrane disassembly during mitosis are adapted for removal of nuclei during fiber cell differentiation. PMID:25139855
Optical design of laser zoom projective lens with variable total track
NASA Astrophysics Data System (ADS)
He, Yulan; Xiao, Xiangguo; Lu, Feng; Li, Yuan; Han, Kunye; Wang, Nanxi; Qiang, Hua
2017-02-01
In order to project the laser command information to the proper distance , so a laser zoom projective lens with variable total track optical system is designed in the carrier-based aircraft landing system. By choosing the zoom structure, designing of initial structure with PW solution, correcting and balancing the aberration, a large variable total track with 35 × zoom is carried out. The size of image is invariable that is φ25m, the distance of projective image is variable from 100m to 3500m. Optical reverse design, the spot is less than 8μm, the MTF is near the diffraction limitation, the value of MTF is bigger than 0.4 at 50lp/mm.
Generation and control of sound bullets with a nonlinear acoustic lens.
Spadoni, Alessandro; Daraio, Chiara
2010-04-20
Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic transducers to image the interior of the human body. Currently however the performance of acoustic devices is limited by their linear operational envelope, which implies relatively inaccurate focusing and low focal power. Here we show a dramatic focusing effect and the generation of compact acoustic pulses (sound bullets) in solid and fluid media, with energies orders of magnitude greater than previously achievable. This focusing is made possible by a tunable, nonlinear acoustic lens, which consists of ordered arrays of granular chains. The amplitude, size, and location of the sound bullets can be controlled by varying the static precompression of the chains. Theory and numerical simulations demonstrate the focusing effect, and photoelasticity experiments corroborate it. Our nonlinear lens permits a qualitatively new way of generating high-energy acoustic pulses, which may improve imaging capabilities through increased accuracy and signal-to-noise ratios and may lead to more effective nonintrusive scalpels, for example, for cancer treatment.
Generation and control of sound bullets with a nonlinear acoustic lens
Spadoni, Alessandro; Daraio, Chiara
2010-01-01
Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic transducers to image the interior of the human body. Currently however the performance of acoustic devices is limited by their linear operational envelope, which implies relatively inaccurate focusing and low focal power. Here we show a dramatic focusing effect and the generation of compact acoustic pulses (sound bullets) in solid and fluid media, with energies orders of magnitude greater than previously achievable. This focusing is made possible by a tunable, nonlinear acoustic lens, which consists of ordered arrays of granular chains. The amplitude, size, and location of the sound bullets can be controlled by varying the static precompression of the chains. Theory and numerical simulations demonstrate the focusing effect, and photoelasticity experiments corroborate it. Our nonlinear lens permits a qualitatively new way of generating high-energy acoustic pulses, which may improve imaging capabilities through increased accuracy and signal-to-noise ratios and may lead to more effective nonintrusive scalpels, for example, for cancer treatment. PMID:20368461
Mechanically assisted liquid lens zoom system for mobile phone cameras
NASA Astrophysics Data System (ADS)
Wippermann, F. C.; Schreiber, P.; Bräuer, A.; Berge, B.
2006-08-01
Camera systems with small form factor are an integral part of today's mobile phones which recently feature auto focus functionality. Ready to market solutions without moving parts have been developed by using the electrowetting technology. Besides virtually no deterioration, easy control electronics and simple and therefore cost-effective fabrication, this type of liquid lenses enables extremely fast settling times compared to mechanical approaches. As a next evolutionary step mobile phone cameras will be equipped with zoom functionality. We present first order considerations for the optical design of a miniaturized zoom system based on liquid-lenses and compare it to its mechanical counterpart. We propose a design of a zoom lens with a zoom factor of 2.5 considering state-of-the-art commercially available liquid lens products. The lens possesses auto focus capability and is based on liquid lenses and one additional mechanical actuator. The combination of liquid lenses and a single mechanical actuator enables extremely short settling times of about 20ms for the auto focus and a simplified mechanical system design leading to lower production cost and longer life time. The camera system has a mechanical outline of 24mm in length and 8mm in diameter. The lens with f/# 3.5 provides market relevant optical performance and is designed for an image circle of 6.25mm (1/2.8" format sensor).
Koshelev, Alexander; Calafiore, Giuseppe; Piña-Hernandez, Carlos; Allen, Frances I; Dhuey, Scott; Sassolini, Simone; Wong, Edward; Lum, Paul; Munechika, Keiko; Cabrini, Stefano
2016-08-01
In this Letter, we present a Fresnel lens fabricated on the end of an optical fiber. The lens is fabricated using nanoimprint lithography of a functional high refractive index material, which is suitable for mass production. The main advantage of the presented Fresnel lens compared to a conventional fiber lens is its high refractive index (n=1.68), which enables efficient light focusing even inside other media, such as water or an adhesive. Measurement of the lens performance in an immersion liquid (n=1.51) shows a near diffraction limited focal spot of 810 nm in diameter at the 1/e2 intensity level for a wavelength of 660 nm. Applications of such fiber lenses include integrated optics, optical trapping, and fiber probes.
NASA Astrophysics Data System (ADS)
Flores-Bustamante, Mario C.; Rosete-Aguilar, Martha; Calixto, Sergio
2016-03-01
A lens containing a liquid medium and having at least one elastic membrane as one of its components is known as an elastic membrane lens (EML). The elastic membrane may have a constant or variable thickness. The optical properties of the EML change by modifying the profile of its elastic membrane(s). The EML formed of elastic constant thickness membrane(s) have been studied extensively. However, EML information using elastic membrane of variable thickness is limited. In this work, we present simulation results of the mechanical and optical behavior of two EML with variable thickness membranes (convex-plane membranes). The profile of its surfaces were modified by liquid medium volume increases. The model of the convex-plane membranes, as well as the simulation of its mechanical behavior, were performed using Solidworks® software; and surface's points of the deformed elastic lens were obtained. Experimental stress-strain data, obtained from a silicone rubber simple tensile test, according to ASTM D638 norm, were used in the simulation. Algebraic expressions, (Schwarzschild formula, up to four deformation coefficients, in a cylindrical coordinate system (r, z)), of the meridional profiles of the first and second surfaces of the deformed convex-plane membranes, were obtained using the results from Solidworks® and a program in the software Mathematica®. The optical performance of the EML was obtained by simulation using the software OSLO® and the algebraic expressions obtained in Mathematica®.
Light absorption cell combining variable path and length pump
Prather, W.S.
1993-12-07
A device is described for use in making spectrophotometric measurements of fluid samples. In particular, the device is a measurement cell containing a movable and a fixed lens with a sample of the fluid there between and through which light shines. The cell is connected to a source of light and a spectrophotometer via optic fibers. Movement of the lens varies the path length and also pumps the fluid into and out of the cell. Unidirectional inlet and exit valves cooperate with the movable lens to assure a one-way flow of fluid through the cell. A linear stepper motor controls the movement of the lens and cycles it from a first position closer to the fixed lens and a second position farther from the fixed lens, preferably at least 10 times per minute for a nearly continuous stream of absorption spectrum data. 2 figures.
NASA Astrophysics Data System (ADS)
Chen, Chun-Jen; Wu, Wen-Hong; Huang, Kuo-Cheng
2009-08-01
A multi-function lens test instrument is report in this paper. This system can evaluate the image resolution, image quality, depth of field, image distortion and light intensity distribution of the tested lens by changing the tested patterns. This system consists of a tested lens, a CCD camera, a linear motorized stage, a system fixture, an observer LCD monitor, and a notebook for pattern providing. The LCD monitor displays a serious of specified tested patterns sent by the notebook. Then each displayed pattern goes through the tested lens and images in the CCD camera sensor. Consequently, the system can evaluate the performance of the tested lens by analyzing the image of CCD camera with special designed software. The major advantage of this system is that it can complete whole test quickly without interruption due to part replacement, because the tested patterns are statically displayed on monitor and controlled by the notebook.
X-ray nanofocusing by kinoform lenses: A comparative study using different modeling approaches
NASA Astrophysics Data System (ADS)
Yan, Hanfei
2010-02-01
We conduct a comparative study on various kinoform lenses (KLs) for x-ray nanofocusing by using the geometrical theory, the dynamical diffraction theory, and the beam propagation method. This study shows that the geometrical theory becomes invalid to describe the performance of a KL for nanofocusing. The strong edge diffraction effect from individual lens element, which distorts the desired wave field, leads to a reduction in the effective numerical aperture and imposes a limit on how small a focus a KL can achieve. Because this effect is associated with a finite thickness of a lens, larger lens thickness depicts a stronger distortion. We find that a short KL where all lens elements are folded back to a single plane shows an illumination preference: if the illuminating geometry is in favor of the Bragg diffraction for a focusing order, its performance is enhanced and vice versa. We also find that a short KL usually outperforms its long version where all lens elements do not lie in a single plane because the short one suffers less the wave field distortion due to the edge diffraction. Simulation results suggest that for a long KL, an adaptive lens design is needed to correct the wave field distortion in order to achieve a better performance.
All plastic ultra-small size imaging lens unit fabrication and evaluation for endoscope
NASA Astrophysics Data System (ADS)
Ishii, Kenta; Okamoto, Dai; Ushio, Makoto; Tai, Hidetoshi; Nishihara, Atsuhiko; Tokuda, Kimio; Kawai, Shinsuke; Kitagawa, Seiichiro
2017-02-01
There is demand for small-size lens units for endoscope and industrial applications. Polished glass lenses with a diameter of 1 - 2mm exist, however plastic lenses similar in size are not commonplace. For low-cost, light-weight, and mass production, plastic lens fabrication is extremely beneficial. Especially, in the medical field, there is strong demand for disposable lens unit for endoscopes which prevent contamination due to reuse of the lens. Therefore, high mass producible and low cost becomes increasingly important. This paper reports our findings on injection-molded ultra-small size plastic lens units with a diameter of 1.3mm and total thickness of 1.4mm. We performed optical design, injection molding, and lens unit assembly for injection moldable, high imaging performance ultra-small sized lens units. We prioritize a robust product design, considering injection molding properties and lens unit assembly, with feedback from molding simulations reflected into the optical design. A mold capable of high precision lens positioning is used to fabricate the lenses and decrease the variability of the assembly. The geometric dimensions of the resulting lenses, are measured and used in the optical simulation to validate the optical performance, and a high agreement is reported. The injection molding of the lens and the assembly of the lens unit is performed with high precision, and results in high optical performance.
Three-dimensional liquid flattened Luneburg lens with ultra-wide viewing angle and frequency band
NASA Astrophysics Data System (ADS)
Wu, Lingling; Tian, Xiaoyong; Yin, Ming; Li, Dichen; Tang, Yiping
2013-08-01
Traditional Luneburg lens is a dielectric spherical antenna. It can focus the incoming collimated electromagnetic waves on its spherical surface, which causes the incompatibility with the planar feeding and receiving devices. Furthermore, the difficulties in the fabrication process also limited its applications. In this paper, a three-dimensional flattened Luneburg lens with a field-of-view angle up to 180° has been realized based on a liquid medium approach and a 3D-printing process. The fabricated three-dimensional lens showed a broadband transmission characteristic from 12.4 GHz to 18 GHz. The performance of the proposed lens was demonstrated by simulation and experimental results.
Coherent x-ray zoom condenser lens for diffractive and scanning microscopy.
Kimura, Takashi; Matsuyama, Satoshi; Yamauchi, Kazuto; Nishino, Yoshinori
2013-04-22
We propose a coherent x-ray zoom condenser lens composed of two-stage deformable Kirkpatrick-Baez mirrors. The lens delivers coherent x-rays with a controllable beam size, from one micrometer to a few tens of nanometers, at a fixed focal position. The lens is suitable for diffractive and scanning microscopy. We also propose non-scanning coherent diffraction microscopy for extended objects by using an apodized focused beam produced by the lens with a spatial filter. The proposed apodized-illumination method will be useful in highly efficient imaging with ultimate storage ring sources, and will also open the way to single-shot coherent diffraction microscopy of extended objects with x-ray free-electron lasers.
In-situ spectrophotometric probe
Prather, W.S.
1992-12-15
A spectrophotometric probe is described for in situ absorption spectra measurements comprising a first optical fiber carrying light from a remote light source, a second optical fiber carrying light to a remote spectrophotometer, the proximal ends of the first and second optical fibers parallel and co-terminal, a planoconvex lens to collimate light from the first optical fiber, a reflecting grid positioned a short distance from the lens to reflect the collimated light back to the lens for focusing on the second optical fiber. The lens is positioned with the convex side toward the optical fibers. A substrate for absorbing analyte or an analyte and reagent mixture may be positioned between the lens and the reflecting grid. 5 figs.
Microelectrofluidic lens for variable curvature
NASA Astrophysics Data System (ADS)
Chang, Jong-hyeon; Lee, Eunsung; Jung, Kyu-Dong; Lee, Seungwan; Choi, Minseog; Kim, Woonbae
2012-10-01
This paper presents a tunable liquid lens based on microelectrofluidic technology which integrates electrowetting and microfluidics. In the novel microelectrofluidic lens (MEFL), electrowetting in the hydrophobic surface channel induces the Laplace pressure difference between two fluidic interfaces on the lens aperture and the surface channel. Then, the pressure difference makes the lens curvature tunable. The previous electrowetting lens in which the contact angle changes at the side wall has a certain limitation of the curvature variation because of the contact angle saturation. Although the contact angle saturation also appears in the surface channel of the MEFL, the low surface channel increases the Laplace pressure and it makes the MEFL to have full variation of the optical power possible. The magnitude of the applied voltage determines the lens curvature in the analog mode MEFL as well as the electrowetting lens. Digital operation is also possible when the control electrodes of the MEFL are patterned to have an array. It is expected that the proposed MEFL is able to be widely used because of its full variation of the optical power without the use of oil and digital operation with fast response.
Bioinspired adaptive gradient refractive index distribution lens
NASA Astrophysics Data System (ADS)
Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael
2018-02-01
Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.
MEMS-based liquid lens for capsule endoscope
NASA Astrophysics Data System (ADS)
Seo, S. W.; Han, S.; Seo, J. H.; Kim, Y. M.; Kang, M. S.; Min, N. G.; Choi, W. B.; Sung, M. Y.
2008-03-01
The capsule endoscope, a new application area of digital imaging, is growing rapidly but needs the versatile imaging capabilities such as auto-focusing and zoom-in to be an active diagnostic tool. The liquid lens based on MEMS technology can be a strong candidate because it is able to be small enough. In this paper, a cylinder-type liquid lens was designed based on Young-Lippmann model and then fabricated with MEMS technology combining the silicon thin-film process and the wafer bonding process. The focal length of the lens module including the fabricated liquid lens was changed reproducibly as a function of the applied voltage. With the change of 30V in the applied bias, the focal length of the constructed lens module could be tuned in the range of about 42cm. The fabricated liquid lens was also proven to be small enough to be adopted in the capsule endoscope, which means the liquid lens can be utilized for the imaging capability improvement of the capsule endoscope.
Instruments for Imaging from Far to Near
NASA Technical Reports Server (NTRS)
Mungas, Greg; Boynton, John; Sepulveda, Cesar
2009-01-01
The acronym CHAMP (signifying camera, hand lens, and microscope ) denotes any of several proposed optoelectronic instruments that would be capable of color imaging at working distances that could be varied continuously through a range from infinity down to several millimeters. As in any optical instrument, the magnification, depth of field, and spatial resolution would vary with the working distance. For example, in one CHAMP version, at a working distance of 2.5 m, the instrument would function as an electronic camera with a magnification of 1/100, whereas at a working distance of 7 mm, the instrument would function as a microscope/electronic camera with a magnification of 4.4. Moreover, as described below, when operating at or near the shortest-working-distance/highest-magnification combination, a CHAMP could be made to perform one or more spectral imaging functions. CHAMPs were originally intended to be used in robotic geological exploration of the Moon and Mars. The CHAMP concept also has potential for diverse terrestrial applications that could include remotely controlled or robotic geological exploration, prospecting, field microbiology, environmental surveying, and assembly- line inspection. A CHAMP (see figure) would include two lens cells: (1) a distal cell corresponding to the objective lens assembly of a conventional telescope or microscope and (2) a proximal cell that would contain the focusing camera lens assembly and the camera electronic image-detector chip, which would be of the active-pixel-sensor (APS) type. The distal lens cell would face outward from a housing, while the proximal lens cell would lie in a clean environment inside the housing. The proximal lens cell would contain a beam splitter that would enable simultaneous use of the imaging optics (that is, proximal and distal lens assemblies) for imaging and illumination of the field of view. The APS chip would be mounted on a focal plane on a side face of the beam splitter, while light for illuminating the field of view would enter the imaging optics via the end face of the beam splitter. The proximal lens cell would be mounted on a sled that could be translated along the optical axis for focus adjustment. The position of the CHAMP would initially be chosen at the desired working distance of the distal lens from (corresponding to an approximate desired magnification of) an object to be examined. During subsequent operation, the working distance would ordinarily remain fixed at the chosen value and the position of the proximal lens cell within the instrument would be adjusted for focus as needed.
Scattering of focused ultrasonic beams by cavities in a solid half-space.
Rahni, Ehsan Kabiri; Hajzargarbashi, Talieh; Kundu, Tribikram
2012-08-01
The ultrasonic field generated by a point focused acoustic lens placed in a fluid medium adjacent to a solid half-space, containing one or more spherical cavities, is modeled. The semi-analytical distributed point source method (DPSM) is followed for the modeling. This technique properly takes into account the interaction effect between the cavities placed in the focused ultrasonic field, fluid-solid interface and the lens surface. The approximate analytical solution that is available in the literature for the single cavity geometry is very restrictive and cannot handle multiple cavity problems. Finite element solutions for such problems are also prohibitively time consuming at high frequencies. Solution of this problem is necessary to predict when two cavities placed in close proximity inside a solid can be distinguished by an acoustic lens placed outside the solid medium and when such distinction is not possible.
Apparatus for precision focussing and positioning of a beam waist on a target
NASA Technical Reports Server (NTRS)
Lynch, Dana H. (Inventor); Gunter, William D. (Inventor); Mcalister, Kenneth W. (Inventor)
1991-01-01
The invention relates to optical focussing apparatus and, more particularly, to optical apparatus for focussing a highly collimated Gaussian beam which provides independent and fine control over the focus waist diameter, the focus position both along the beam axis and transverse to the beam, and the focus angle. A beam focussing and positioning apparatus provides focussing and positioning for the waist of a waisted beam at a desired location on a target such as an optical fiber. The apparatus includes a first lens, having a focal plane f sub 1, disposed in the path of an incoming beam and a second lens, having a focal plane f sub 2 and being spaced downstream from the first lens by a distance at least equal to f sub 1 + 10 f sub 2, which cooperates with the first lens to focus the waist of the beam on the target. A rotatable optical device, disposed upstream of the first lens, adjusts the angular orientation of the beam waist. The transverse position of the first lens relative to the axis of the beam is varied to control the transverse position of the beam waist relative to the target (a fiber optic as shown) while the relative axial positions of the lenses are varied to control the diameter of the beam waist and to control the axial position of the beam waist. Mechanical controllers C sub 1, C sub 2, C sub 3, C sub 4, and C sub 5 control the elements of the optical system. How seven adjustments can be made to correctly couple a laser beam into an optical fiber is illustrated. Prior art systems employing optical techniques to couple a laser beam into an optical fiber or other target simply do not provide the seven necessary adjustments. The closest known prior art, a Newport coupler, provides only two of the seven required adjustments.
Simulated imaging properties of a series of magnetic electron lenses
NASA Technical Reports Server (NTRS)
Kory, Carol L.
1995-01-01
The paraxial lens data were determined for a series of symmetrical magnetic lenses of equal lens diameter but variable air gap width for a wide range of lens excitations using the three-dimensional electrodynamic computer code MAFIA. The results are compared with a similar study done by Liebman and Grad wherein the field distributions within the lenses were measured experimentally with a resistance network analogue. Using these fields the lens data were obtained through numerical trajectory tracing. The utility of using MAFIA, instead of experimental methods for lens design is shown by the excellent agreement of the simulated results compared to experiment. Also demonstrated is the capability of using MAFIA to investigate aberration sources such as higher order off-axis magnetic field and space-charge effects.
Farah, J; Struelens, L; Auvinen, A; Jacob, S; Koukorava, C; Schnelzer, M; Vanhavere, F; Clairand, I
2015-04-01
In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Presley, Todd K.
2005-01-01
Lower than average rainfall during late 1997 and early 1998 in Majuro Atoll, Republic of the Marshall Islands, caused a drought and severe drinking-water shortage. Majuro depends on a public rainfall catchment system, which uses an airport runway and storage reservoirs. The storage reservoirs can supply water for about 30 to 50 days without replenishment. In February 1998, after a few months with less than one inch of rainfall per month, a drought-related disaster was declared. Reverse-osmosis water-purification systems were brought to Majuro to help alleviate the water shortage. Concurrent with the water-purification program, ground water from a freshwater lens in the Laura area of the atoll was pumped at increased rates. Of the total consumed water during this period, ground water from Laura supplied between 90 percent (March 1998) and 64 percent (May 1998) of the drinking water. Due to public concern, a study was initiated to determine the effects of the drought on the freshwater lens. The areal extent of the freshwater lens is about 350 acres. A monitoring-well network, consisting of multiple wells driven to varying depths at 11 sites, was installed to determine the thickness of the freshwater lens. Similar locations relative to an earlier study were chosen so that the data from this study could be compared to 1984-85 data. At the end of the drought in June 1998, the freshwater near the middle of the lens was about 45 feet thick; and at the north and south ends, the freshwater was about 25 to 38 feet thick, respectively. Monitoring of the freshwater lens was continued through the wet season following the drought. The lens increased in thickness by 1 to 8 feet after 7 months of rainfall. Greater increases in lens thickness were measured on the lagoon side than on the ocean side of the freshwater lens. Lens thickness during August 1998, and seasonal variation of lens thickness in 1998, were compared to data collected in 1984-85. Comparison of lens thickness from the different years yielded an inconsistent result; the lens was not uniformly thicker in 1984-85 despite more rainfall and little or no pumpage during this time. Seasonal variation in 1998-99 was greater than seasonal variation in 1984-85 due to differences in seasonal rainfall and pumpage. The change in lens thickness suggested by the comparison between 1998-99 and 1984-85 data was complicated by effects due to different well locations, different wells, and assumed small-scale variability in the thickness of fine and coarse calcareous sediments. This result suggests that a monitoring program that uses the same wells through time is needed to adequately describe long-term variability in lens thickness.
Ultrasound field measurement using a binary lens
Clement, G.T.; Nomura, H.; Kamakura, T.
2014-01-01
Field characterization methods using a scattering target in the absence of a point-like receiver have been well described in which scattering is recorded by a relatively large receiver located outside the field of measurement. Unfortunately, such methods are prone to artifacts due to averaging across the receiver surface. To avoid this problem while simultaneously increasing the gain of a received signal, the present study introduces a binary plate lens designed to focus spherically-spreading waves onto a planar region having a nearly-uniform phase proportional to that of the target location. The lens is similar to a zone plate, but modified to produce a biconvex-like behavior, such that it focuses both planar and spherically spreading waves. A measurement device suitable for characterizing narrowband ultrasound signals in air is designed around this lens by coupling it to a target and planar receiver. A prototype device is constructed and used to characterize the field of a highly-focused 400 kHz air transducer along 2 radial lines. Comparison of the measurements with numeric predictions formed from nonlinear acoustic simulation showed good relative pressure correlation, with mean differences of 10% and 12% over center 3dB FWHM drop and 12% and 17% over 6dB. PMID:25643084
Zoned near-zero refractive index fishnet lens antenna: Steering millimeter waves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pacheco-Peña, V., E-mail: victor.pacheco@unavarra.es; Orazbayev, B., E-mail: b.orazbayev@unavarra.es; Beaskoetxea, U., E-mail: unai.beaskoetxea@unavarra.es
2014-03-28
A zoned fishnet metamaterial lens is designed, fabricated, and experimentally demonstrated at millimeter wavelengths to work as a negative near-zero refractive index lens suitable for compact lens antenna configurations. At the design frequency f = 56.7 GHz (λ{sub 0} = 5.29 mm), the zoned fishnet metamaterial lens, designed to have a focal length FL = 9λ{sub 0}, exhibits a refractive index n = −0.25. The focusing performance of the diffractive optical element is briefly compared with that of a non-zoned fishnet metamaterial lens and an isotropic homogeneous zoned lens made of a material with the same refractive index. Experimental and numerically-computed radiation diagrams of the fabricated zoned lens are presentedmore » and compared in detail with that of a simulated non-zoned lens. Simulation and experimental results are in good agreement, demonstrating an enhancement generated by the zoned lens of 10.7 dB, corresponding to a gain of 12.26 dB. Moreover, beam steering capability of the structure by shifting the feeder on the xz-plane is demonstrated.« less
Yokoyama, Sumi; Hamada, Nobuyuki; Hayashida, Toshiyuki; Tsujimura, Norio; Tatsuzaki, Hideo; Kurosawa, Tadahiro; Nabatame, Kuniaki; Ohguchi, Hiroyuki; Ohno, Kazuko; Yamauchi-Kawaura, Chiyo; Iimoto, Takeshi; Ichiji, Takeshi; Hotta, Yutaka; Iwai, Satoshi; Akahane, Keiichi
2017-09-25
Since the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens of the eye in 2011, there have been extensive discussions in various countries. This paper reviews the current situation in radiation protection of the ocular lens and the discussions on the potential impact of the new lens dose limit in Japan. Topics include historical changes to the lens dose limit, the current situation with occupational lens exposures (e.g., in medical workers, nuclear workers, and Fukushima nuclear power plant workers) and measurements, and the current status of biological studies and epidemiological studies on radiation cataracts. Our focus is on the situation in Japan, but we believe such information sharing will be useful in many other countries.
Large-memory real-time multichannel multiplexed pattern recognition
NASA Technical Reports Server (NTRS)
Gregory, D. A.; Liu, H. K.
1984-01-01
The principle and experimental design of a real-time multichannel multiplexed optical pattern recognition system via use of a 25-focus dichromated gelatin holographic lens (hololens) are described. Each of the 25 foci of the hololens may have a storage and matched filtering capability approaching that of a single-lens correlator. If the space-bandwidth product of an input image is limited, as is true in most practical cases, the 25-focus hololens system has 25 times the capability of a single lens. Experimental results have shown that the interfilter noise is not serious. The system has already demonstrated the storage and recognition of over 70 matched filters - which is a larger capacity than any optical pattern recognition system reported to date.
Image translation for single-shot focal tomography
Llull, Patrick; Yuan, Xin; Carin, Lawrence; ...
2015-01-01
Focus and depth of field are conventionally addressed by adjusting longitudinal lens position. More recently, combinations of deliberate blur and computational processing have been used to extend depth of field. Here we show that dynamic control of transverse and longitudinal lens position can be used to decode focus and extend depth of field without degrading static resolution. Our results suggest that optical image stabilization systems may be used for autofocus, extended depth of field, and 3D imaging.
Two-Dimensional Simulation of Left-Handed Metamaterial Flat Lens Using Remcon XFDTD
NASA Technical Reports Server (NTRS)
Wilson, Jeffrey D.; Reinert, Jason M.
2006-01-01
Remcom's XFDTD software was used to model the properties of a two-dimensional left-handed metamaterial (LHM) flat lens. The focusing capability and attenuation of the material were examined. The results showed strong agreement with experimental results and theoretical predictions of focusing effects and focal length. The inherent attenuation in the model corresponds well with the experimental results and implies that the code does a reasonably accurate job of modeling the actual metamaterial.
Slot-grating flat lens for telecom wavelengths.
Pugh, Jonathan R; Stokes, Jamie L; Lopez-Garcia, Martin; Gan, Choon-How; Nash, Geoff R; Rarity, John G; Cryan, Martin J
2014-07-01
We present a stand-alone beam-focusing flat lens for use in the telecommunications wavelength range. Light incident on the back surface of the lens propagates through a subwavelength aperture and is heavily diffracted on exit and partially couples into a surface plasmon polariton and a surface wave propagating along the surface of the lens. Interference between the diffracted wave and re-emission from a grating patterned on the surface produces a highly collimated beam. We show for the first time a geometry at which a lens of this type can be used at telecommunication wavelengths (λ=1.55 μm) and identify the light coupling and re-emission mechanisms involved. Measured beam profile results at varying incident wavelengths show excellent agreement with Lumerical FDTD simulation results.
NASA Technical Reports Server (NTRS)
Oneill, Mark J.; Mcdanal, A. J.; Spears, Don H.
1989-01-01
The primary project objective was to generate a conceptual design for a nominal 5 kW solar dynamic space power system, which uses a unique, patented, transmittance-optimized, dome-shaped, point-focus Fresnel lens as the optical concentrator. Compared to reflective concentrators, the dome lens allows 200 times larger slope errors for the same image displacement. Additionally, the dome lens allows the energy receiver, the power conversion unit (PCU), and the heat rejection radiator to be independently optimized in configuration and orientation, since none of these elements causes any aperture blockage. Based on optical and thermal trade studies, a 6.6 m diameter lens with a focal length of 7.2 m was selected. This lens should provide 87 percent net optical efficienty at 800X geometric concentration ratio. The large lens is comprised of 24 gores, which compactly stow together during launch, and automatically deploy on orbit. The total mass of the microglass lens panels, the graphite/epoxy support structure, and miscellaneous hardware is about 1.2 kg per square meter of aperture. The key problem for the dome lens approach relates to the selection of a space-durable lens material. For the first time, all-glass Fresnel lens samples were successfully made by a sol-gel casting process.
Wu, Chen; Han, Zhaolong; Wang, Shang; Li, Jiasong; Singh, Manmohan; Liu, Chih-hao; Aglyamov, Salavat; Emelianov, Stanislav; Manns, Fabrice; Larin, Kirill V.
2015-01-01
Purpose. To evaluate the capability of a novel, coaligned focused ultrasound and phase-sensitive optical coherence elastography (US-OCE) system to assess age-related changes in biomechanical properties of the crystalline lens in situ. Methods. Low-amplitude elastic deformations in young and mature rabbit lenses were measured by an US-OCE system consisting of a spectral-domain optical coherence tomography (OCT) system coaligned with a focused ultrasound system used to produce a transient force on the lens surface. Uniaxial compressional tests were used to validate the OCE data. Results. The OCE measurements showed that the maximum displacements of the young rabbit lenses were significantly larger than those of the mature lenses, indicating a gradual increase of the lens stiffness with age. Temporal analyses of the displacements also demonstrate a similar trend of elastic properties in these lenses. The stress-strain measurements using uniaxial mechanical tests confirmed the results obtained by the US-OCE system. Conclusions. The results demonstrate that the US-OCE system can be used for noninvasive analysis and quantification of lens biomechanical properties in situ and possibly in vivo. PMID:25613945
Electrically tunable soft solid lens inspired by reptile and bird accommodation.
Pieroni, Michael; Lagomarsini, Clara; De Rossi, Danilo; Carpi, Federico
2016-10-26
Electrically tunable lenses are conceived as deformable adaptive optical components able to change focus without motor-controlled translations of stiff lenses. In order to achieve large tuning ranges, large deformations are needed. This requires new technologies for the actuation of highly stretchable lenses. This paper presents a configuration to obtain compact tunable lenses entirely made of soft solid matter (elastomers). This was achieved by combining the advantages of dielectric elastomer actuation (DEA) with a design inspired by the accommodation of reptiles and birds. An annular DEA was used to radially deform a central solid-body lens. Using an acrylic elastomer membrane, a silicone lens and a simple fabrication method, we assembled a tunable lens capable of focal length variations up to 55%, driven by an actuator four times larger than the lens. As compared to DEA-based liquid lenses, the novel architecture halves the required driving voltages, simplifies the fabrication process and allows for a higher versatility in design. These new lenses might find application in systems requiring large variations of focus with low power consumption, silent operation, low weight, shock tolerance, minimized axial encumbrance and minimized changes of performance against vibrations and variations in temperature.
Schaeffel, F; Bartmann, M; Hagel, G; Zrenner, E
1995-05-01
We have found that development of both deprivation-induced and lens-induced refractive errors in chickens implicates changes of the diurnal growth rhythms in the eye (Fig. 1). Because the major diurnal oscillator in the eye is expressed by the retinal dopamine/melatonin system, effects of drugs were studied that change retinal dopamine and/or serotonin levels. Vehicle-injected and drug-injected eyes treated with either translucent occluders or lenses were compared to focus on visual growth mechanisms. Retinal biogenic amine levels were measured at the end of each experiment by HPLC with electrochemical detection. For reserpine (which was most extensively studied) electroretinograms were recorded to test retinal function [Fig. 3 (C)] and catecholaminergic and serotonergic retinal neurons were observed by immunohistochemical labelling [Fig. 3(D)]. Deprivation myopia was readily altered by a single intravitreal injection of drugs that affected retinal dopamine or serotonin levels; reserpine which depleted both serotonin and dopamine stores blocked deprivation myopia very efficiently [Fig. 3(A)], whereas 5,7-dihydroxy-tryptamine (5,7-DHT), sulpiride, melatonin and Sch23390 could enhance deprivation myopia (Table 1, Fig. 5). In contrast to other procedures that were previously employed to block deprivation myopia (6-OHDA injections or continuous light) and which had no significant effect on lens-induced refractive errors, reserpine also affected lens-induced changes in eye growth. At lower doses, the effect was selective for negative lenses (Fig. 4). We found that the individual retinal dopamine levels were very variable among individuals but were correlated in both eyes of an animal; a similar variability was previously found with regard to deprivation myopia. To test a hypothesis raised by Li, Schaeffel, Kohler and Zrenner [(1992) Visual Neuroscience, 9, 483-492] that individual dopamine levels might determine the susceptibility to deprivation myopia, refractive errors were correlated with dopamine levels in occluded and untreated eyes of monocularly deprived chickens (Fig. 6). The hypothesis was rejected. Although it has been previously found that the static retinal tissue levels of dopamine are not altered by lens treatment, subtle changes in the ratio of DOPAC to dopamine were detected in the present study. The result indicates that retinal dopamine might be implicated also in lens-induced growth changes. Surprisingly, the changes were in the opposite direction for deprivation and negative lenses although both produce myopia. Currently, there is evidence that deprivation-induced and lens-induced refractive errors in chicks are produced by different mechanisms. However, findings (1), (3) and (5) suggest that there may also be common features. Although it has not yet been resolved how both mechanisms merge to produce the appropriate axial eye growth rates, we propose a scheme (Fig. 7).
NASA Astrophysics Data System (ADS)
Chu, Jiyoung; Cho, Sungwhi; Joo, Won Don; Jang, Sangdon
2017-08-01
One of the most popular methods for high precision lens assembly of an optical system is using an autocollimator and a rotation stage. Some companies provide software for calculating the state of the lens along with their lens assembly systems, but the calculation algorithms used by the software are unknown. In this paper, we suggest a calculation method for lens alignment errors using ray transfer matrices. Alignment errors resulting from tilting and decentering of a lens element can be calculated from the tilts of the front and back surfaces of the lens. The tilt of each surface can be obtained from the position of the reticle image on the CCD camera of the autocollimator. Rays from a reticle of the autocollimator are reflected from the target surface of the lens, which rotates with the rotation stage, and are imaged on the CCD camera. To obtain a clear image, the distance between the autocollimator and the first lens surface should be adjusted according to the focusing lens of the autocollimator and the lens surfaces from the first to the target surface. Ray propagations for the autocollimator and the tilted lens surfaces can be expressed effectively by using ray transfer matrices and lens alignment errors can be derived from them. This method was compared with Zemax simulation for various lenses with spherical or flat surfaces and the error was less than a few percent.
Miccio, L; Finizio, A; Grilli, S; Vespini, V; Paturzo, M; De Nicola, S; Ferraro, Pietro
2009-02-16
A special class of tunable liquid microlenses is presented here. The microlenses are generated by an electrowetting effect under an electrode-less configuration and they exhibit two different regimes that are named here as separated lens regime (SLR) and wave-like lens regime (WLR). The lens effect is induced by the pyroelectricity of polar dielectric crystals, as was proved in principle in a previous work by the same authors (S. Grilli et al., Opt. Express 16, 8084, 2008). Compared to that work, the improvements to the experimental set-up and procedure allow to reveal the two lens regimes which exhibit different optical properties. A digital holography technique is used to reconstruct the transmitted wavefront during focusing and a focal length variation in the millimetre range is observed. The tunability of such microlenses could be of great interest to the field of micro-optics thanks to the possibility to achieve focus tuning without moving parts and thus favouring the miniaturization of the optical systems.
Cylindrically symmetric Fresnel lens for high concentration photovoltaic
NASA Astrophysics Data System (ADS)
Hung, Yu-Ting; Su, Guo-Dung
2009-08-01
High concentration photovoltaic (HCPV) utilizes point-focus cost-effective plastic Fresnel lens. And a millimeter-sized Ill-V compound multi-junction solar cell is placed underneath focusing optics which can achieve cell efficiency potential of up to 40.7 %. The advantage of HCPV makes less solar cell area and higher efficiency; however, the acceptance angle of HCPV is about +/-1°, which is very small and the mechanical tracking of the sun is necessary. In order to reduce the power consumption and the angle tracking error of tracking systems, a light collector model with larger acceptance angle is designed with ZEMAX®. In this model, the original radially symmetric Fresnel lens of HCPV is replaced by cylindrically symmetric Fresnel lens and a parabolic reflective surface. Light is collected in two dimensions separately. And a couple of lenses and a light pipe are added before the solar cell chip in order to collect more light when sun light deviates from incident angle of 00. An acceptance angle of +/-10° is achieved with GCR 400.
Dynamic metasurface lens based on MEMS technology
NASA Astrophysics Data System (ADS)
Roy, Tapashree; Zhang, Shuyan; Jung, Il Woong; Troccoli, Mariano; Capasso, Federico; Lopez, Daniel
2018-02-01
In the recent years, metasurfaces, being flat and lightweight, have been designed to replace bulky optical components with various functions. We demonstrate a monolithic Micro-Electro-Mechanical System (MEMS) integrated with a metasurface-based flat lens that focuses light in the mid-infrared spectrum. A two-dimensional scanning MEMS platform controls the angle of the lens along two orthogonal axes by ±9°, thus enabling dynamic beam steering. The device could be used to compensate for off-axis incident light and thus correct for aberrations such as coma. We show that for low angular displacements, the integrated lens-on-MEMS system does not affect the mechanical performance of the MEMS actuators and preserves the focused beam profile as well as the measured full width at half maximum. We envision a new class of flat optical devices with active control provided by the combination of metasurfaces and MEMS for a wide range of applications, such as miniaturized MEMS-based microscope systems, LIDAR scanners, and projection systems.
Second generation crystals for Laue lens applications
NASA Astrophysics Data System (ADS)
Barrière, N.; von Ballmoos, P.; Bastie, P.; Courtois, P.; Abrosimov, N. V.; Andersen, K.; Halloin, H.; Skinner, G.; Smither, R. K.
2006-06-01
A Laue lens gamma-ray telescope represents an exciting concept for a future high-energy mission. The feasibility of such a lens has been demonstrated by the CLAIRE lens prototype; since then various mission concepts featuring a Laue lens are being developed. The latest, which is also the most ambitious, is the European Gamma-Ray Imager (GRI). However, advancing from the CLAIRE prototype to a scientifically exploitable Laue lens requires still substantial research and development. First and foremost, diffracting elements (crystals) that constitute the Laue lens have to be optimized to offer the best efficiency and imaging capabilities for the resulting telescope. The characteristics of selected candidate crystals were measured at the European Synchrotron Radiation Facility on the high-energy beamline ID 15A using a beam tuned at 292 keV. The studied low mosaicity copper crystals have shown absolute reflectivity reaching 30%. These crystals are promising for the realization of a Laue lens, despite the fact that they produce a diffracted beam featuring a Gaussian intensity profile, which contributes to the spread of the focal spot. A composition gradient Si 1-x-Ge x crystal has been investigated as well, which showed a diffraction efficiency reaching 50% (disregarding absorption) - half of the theoretical maximum - that represents an absolute reflectivity around 39 %, the best that we measured at this energy to date. This gradient crystal also showed a square-shaped rocking curve that is almost the best case to minimize the spread of the focal spot. We also show that bending a gradient crystal could still enhance the focusing. Thanks to the better focusing, a factor of 2 in sensitivity improvement may be achieved.
Role of Aquaporin 0 in lens biomechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sindhu Kumari, S.; Gupta, Neha; Shiels, Alan
Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showedmore » the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer fiber cell shape, architecture and integrity. To our knowledge, this is the first report identifying the involvement of an aquaporin in lens biomechanics. Since accommodation is required in human lenses for proper focusing, alteration in the adhesion and/or water channel functions of AQP0 could contribute to presbyopia. - Highlights: • AQP0 aids in lens biomechanics. • AQP0 provides lens stiffness. • AQP0 is critical for lens transparency. • AQP0 could play a significant role in lens accommodation in human. • Alteration in the function(s) of lens AQP0 could lead to presbyopia.« less
Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldstein, Lee
This is the Final Progress Report for DOE-funded research project DE-PS02-08ER08-01 titled “Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens”. The project focuses on the effects of low-linear energy transfer (LET) radiation on the ocular lens. The lens is an exquisitely radiosensitive tissue with a highly-ordered molecular structure that is amenable to non-invasive optical study from the periphery. These merits point to the lens as an ideal target for laser-based molecular biodosimetry (MBD). Following exposure to different types of ionizing radiations, the lens demonstrates molecular changes (e.g., oxidation, racemization, crosslinkage, truncation, aggregation, etc.) thatmore » impact the structure and function of the long-lived proteins in the cytosol of lens fiber cells. The vast majority of proteins in the lens comprise the highly-ordered crystallins. These highly conserved lens proteins are amongst the most concentrated and stable in the body. Once synthesized, the crystallins are retained in the fiber cell cytoplasm for life. Taken together, these properties point to the lens as an ideal system for quantitative in vivo MBD assessment using quasi-elastic light scattering (QLS) analysis. In this project, we deploy a purpose-designed non-invasive infrared laser QLS instrument as a quantitative tool for longitudinal assessment of pre-cataractous molecular changes in the lenses of living mice exposed to low-dose low-LET radiation compared to non-irradiated sham controls. We hypothesize that radiation exposure will induce dose-dependent changes in the molecular structure of matrix proteins in the lens. Mechanistic assays to ascertain radiation-induced molecular changes in the lens focus on protein aggregation and gene/protein expression patterns. We anticipate that this study will contribute to our understanding of early molecular changes associated with radiation-induced tissue pathology. This study also affords potential for translational development of molecular biodosimetry instrumentation to assess human exposure to mixed radiation fields.« less
Realization of an ultrathin acoustic lens for subwavelength focusing in the megasonic range.
Hyun, Jaeyub; Kim, Yong Tae; Doh, Il; Ahn, Bongyoung; Baik, Kyungmin; Kim, Se-Hwa
2018-06-14
In this study, we report the first experimental realization of an ultrathin (0.14λ, λ = 1.482 mm means wavelength at 1 MHz in the water medium) subwavelength focusing acoustic lens that can surpass the Rayleigh diffraction limit (0.61λ/NA, NA means numerical aperture). It is termed a Super-Oscillatory Acoustic Lens (SOAL), and it operates in the megasonic range. The SOAL represents an interesting feature allowing the achievement of subwavelength focusing without the need to operate in close proximity to the object to be imaged. The optimal layout of the SOAL is obtained by utilizing a systematic design approach, referred to here as topology optimization. To this end, the optimization formulation is newly defined. The optimized SOAL is fabricated using a photo-etching process and its subwavelength focusing performance is verified experimentally via an acoustic intensity measurement system. From these measurements, we found that the proposed optimized SOAL can achieve superior focusing features with a Full Width at Half Maximum (FWHM) of ~0.40λ/NA ≃ 0.84 mm (for our SOAL, NA = 0.707) with the transmission efficiency of 26.5%.
Three-dimensional light trap for reflective particles
Neal, D.R.
1999-08-17
A system is disclosed for containing either a reflective particle or a particle having an index of refraction lower than that of the surrounding media in a three-dimensional light cage. A light beam from a single source illuminates an optics system and generates a set of at least three discrete focused beams that emanate from a single exit aperture and focus on to a focal plane located close to the particle. The set of focal spots defines a ring that surrounds the particle. The set of focused beams creates a ``light cage`` and circumscribes a zone of no light within which the particle lies. The surrounding beams apply constraining forces (created by radiation pressure) to the particle, thereby containing it in a three-dimensional force field trap. A diffractive element, such as an aperture multiplexed lens, or either a Dammann grating or phase element in combination with a focusing lens, may be used to generate the beams. A zoom lens may be used to adjust the size of the light cage, permitting particles of various sizes to be captured and contained. 10 figs.
Gamma-ray lens development status for a European gamma-ray imager
NASA Astrophysics Data System (ADS)
Frontera, F.; Pisa, A.; Carassiti, V.; Evangelisti, F.; Loffredo, G.; Pellicciotta, D.; Andersen, K. H.; Courtois, P.; Amati, L.; Caroli, E.; Franceschini, T.; Landini, G.; Silvestri, S.; Stephen, J. B.
2006-06-01
A breakthrough in the sensitivity level of the hard X-/gamma-ray telescopes, which today are based on detectors that view the sky through (or not) coded masks, is expected when focusing optics will be available also in this energy range. Focusing techniques are now in an advanced stage of development. To date the most efficient technique to focus hard X-rays with energies above 100 keV appears to be the Bragg diffraction from crystals in transmission configuration (Laue lenses). Crystals with mosaic structure appear to be the most suitable to build a Laue lens with a broad passband, even though other alternative structures are being investigated. The goal of our project is the development of a broad band focusing telescope based on gamma-ray lenses for the study of the continuum emission of celestial sources from 60 keV up to >600 keV. We will report details of our project, its development status and results of our assessment study of a lens configuration for the European Gamma Ray Imager (GRI) mission now under study for the ESA plan Cosmic Vision 2015-2025.
NASA Astrophysics Data System (ADS)
Guo, Limin; Liu, Youqiang; Huang, Rui; Wang, Zhiyong
2017-06-01
High concentrating PV systems rely on large Fresnel lens that must be precisely oriented in the direction of the Sun to maintain high concentration ratio. We propose a new Fresnel lens design method combining equal-width and equal-height of grooves in this paper based on the principle of focused spot maximum energy. In the ring band near the center of Fresnel lens, the design with equal-width grooves is applied, and when the given condition is reached, the design with equal-height grooves is introduced near the edges of the Fresnel lens, which ensures all the lens grooves are planar. In this paper, we establish a Fresnel lens design example model by Solidworks, and simulate it with the software ZEMAX. An experimental test platform is built to test, and the simulation correctness is proved by experiments. Experimental result shows the concentrating efficiency of this example is 69.3%, slightly lower than the simulation result 75.1%.
428th Brookhaven Lecture. Lighthouses, Light Sources and the Kinoform Route to 1nm
Evans-Lutterodt, Kenneth
2017-12-11
At Brookhaven Lab, a team of researchers has overcome a major x-ray focusing obstacle to allow the study of molecules, atoms, and advanced materials at the nanoscale, which is on the order of billionths of a meter. Their innovative method uses a type of refractive lens called a kinoform lens --similar to the kind found in lighthouses -- in order to focus the x-rays down to the extremely small spots needed for a sharp image at small dimensions.
High transmission Ni compound refractive lens for high energy X-rays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brancewicz, M., E-mail: brancew@spring8.or.jp; Itou, M.; Sakurai, Y.
We present a new planar Ni compound refractive lens for high energy X-rays (116 keV). The lens is composed of identical plano-concave elements with longitudinal parabolic grooves manufactured by a punch technique. In order to increase the lens transmission, the thickness of the single lens at the parabolic groove vertex was reduced to less than 5 μm and the radius of curvature was reduced to about 20 μm. The small radius of curvature allowed us to reduce the number of single elements needed to get the focal length of 3 m to 54 single lenses. The gain parameter has beenmore » significantly improved compared to the previous lenses due to higher transmission, but the focused beam size and its gain are not as good as expected, mostly due to the aberrations caused by the lens shape imperfections.« less
Martin, Heiner; Guthoff, Rudolf; Schmitz, Klaus-Peter
2011-09-01
Polymer injection into the capsular bag after phakoemulsification is an interesting and promising approach to lens surgery. Safe clinical application of this technique will require an appropriate estimate of the effect of implantation variables on the lens power. This article details the results of finite element investigations into the effects of the injected polymer volume and capsular bag contraction on the resultant lens power and accommodation amplitude. An axisymmetric finite element model was created from literature sources. Polymer injection and the capsular contraction were simulated, and their effect on the lens power was calculated. The simulations show that overfilling during polymer injection leads to a refractive power increase of the lens. Capsular bag contraction also results in a power increase. The calculated accommodative amplitude of the lens is minimally affected by capsular bag contraction but decreases significantly with increased capsular bag stiffness as a result of fibrosis. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.
In Vivo Brillouin Analysis of the Aging Crystalline Lens.
Besner, Sebastien; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun
2016-10-01
To analyze the age dependence of the longitudinal modulus of the crystalline lens in vivo using Brillouin scattering data in healthy subjects. Brillouin scans were performed along the crystalline lens in 56 eyes from 30 healthy subjects aged from 19 to 63 years. Longitudinal elastic modulus was acquired along the sagittal axis of the lens with a transverse and axial resolution of 4 and 60 μm, respectively. The relative lens stiffness was computed, and correlations with age were analyzed. Brillouin axial profiles revealed nonuniform longitudinal modulus within the lens, increasing from a softer periphery toward a stiffer central plateau at all ages. The longitudinal modulus at the central plateau showed no age dependence in a range of 19 to 45 years and a slight decrease with age from 45 to 63 years. A significant intersubject variability was observed in an age-matched analysis. Importantly, the extent of the central stiff plateau region increased steadily over age from 19 to 63 years. The slope of change in Brillouin modulus in the peripheral regions were nearly age-invariant. The adult human lens showed no measurable age-related increase in the peak longitudinal modulus. The expansion of the stiff central region of the lens is likely to be the major contributing factor to age-related lens stiffening. Brillouin microscopy may be useful in characterizing the crystalline lens for the optimization of surgical or pharmacological treatments aimed at restoring accommodative power.
Metamaterial-based half Maxwell fish-eye lens for broadband directive emissions
NASA Astrophysics Data System (ADS)
Dhouibi, Abdallah; Nawaz Burokur, Shah; de Lustrac, André; Priou, Alain
2013-01-01
The broadband directive emission from a metamaterial surface is numerically and experimentally reported. The metasurface, composed of non-resonant complementary closed ring structures, is designed to obey the refractive index of a half Maxwell fish-eye lens. A planar microstrip Vivaldi antenna is used as transverse magnetic polarized wave launcher for the lens. A prototype of the lens associated with its feed structure has been fabricated using standard lithography techniques. To experimentally demonstrate the broadband focusing properties and directive emissions, both the far-field radiation patterns and the near-field distributions have been measured. Measurements agree quantitatively and qualitatively with theoretical simulations.
Development of a c-scan photoacoutsic imaging probe for prostate cancer detection
NASA Astrophysics Data System (ADS)
Valluru, Keerthi S.; Chinni, Bhargava K.; Rao, Navalgund A.; Bhatt, Shweta; Dogra, Vikram S.
2011-03-01
Prostate cancer is the second leading cause of death in American men after lung cancer. The current screening procedures include Digital Rectal Exam (DRE) and Prostate Specific Antigen (PSA) test, along with Transrectal Ultrasound (TRUS). All suffer from low sensitivity and specificity in detecting prostate cancer in early stages. There is a desperate need for a new imaging modality. We are developing a prototype transrectal photoacoustic imaging probe to detect prostate malignancies in vivo that promises high sensitivity and specificity. To generate photoacoustic (PA) signals, the probe utilizes a high energy 1064 nm laser that delivers light pulses onto the prostate at 10Hz with 10ns duration through a fiber optic cable. The designed system will generate focused C-scan planar images using acoustic lens technology. A 5 MHz custom fabricated ultrasound sensor array located in the image plane acquires the focused PA signals, eliminating the need for any synthetic aperture focusing. The lens and sensor array design was optimized towards this objective. For fast acquisition times, a custom built 16 channel simultaneous backend electronics PCB has been developed. It consists of a low-noise variable gain amplifier and a 16 channel ADC. Due to the unavailability of 2d ultrasound arrays, in the current implementation several B-scan (depth-resolved) data is first acquired by scanning a 1d array, which is then processed to reconstruct either 3d volumetric images or several C-scan planar images. Experimental results on excised tissue using a in-vitro prototype of this technology are presented to demonstrate the system capability in terms of resolution and sensitivity.
A new numerical benchmark of a freshwater lens
NASA Astrophysics Data System (ADS)
Stoeckl, L.; Walther, M.; Graf, T.
2016-04-01
A numerical benchmark for 2-D variable-density flow and solute transport in a freshwater lens is presented. The benchmark is based on results of laboratory experiments conducted by Stoeckl and Houben (2012) using a sand tank on the meter scale. This benchmark describes the formation and degradation of a freshwater lens over time as it can be found under real-world islands. An error analysis gave the appropriate spatial and temporal discretization of 1 mm and 8.64 s, respectively. The calibrated parameter set was obtained using the parameter estimation tool PEST. Comparing density-coupled and density-uncoupled results showed that the freshwater-saltwater interface position is strongly dependent on density differences. A benchmark that adequately represents saltwater intrusion and that includes realistic features of coastal aquifers or freshwater lenses was lacking. This new benchmark was thus developed and is demonstrated to be suitable to test variable-density groundwater models applied to saltwater intrusion investigations.
Wafer-level fabrication of arrays of glass lens doublets
NASA Astrophysics Data System (ADS)
Passilly, Nicolas; Perrin, Stéphane; Albero, Jorge; Krauter, Johann; Gaiffe, Olivier; Gauthier-Manuel, Ludovic; Froehly, Luc; Lullin, Justine; Bargiel, Sylwester; Osten, Wolfgang; Gorecki, Christophe
2016-04-01
Systems for imaging require to employ high quality optical components in order to dispose of optical aberrations and thus reach sufficient resolution. However, well-known methods to get rid of optical aberrations, such as aspherical profiles or diffractive corrections are not easy to apply to micro-optics. In particular, some of these methods rely on polymers which cannot be associated when such lenses are to be used in integrated devices requiring high temperature process for their further assembly and separation. Among the different approaches, the most common is the lens splitting that consists in dividing the focusing power between two or more optical components. In here, we propose to take advantage of a wafer-level technique, devoted to the generation of glass lenses, which involves thermal reflow in silicon cavities to generate lens doublets. After the convex lens sides are generated, grinding and polishing of both stack sides allow, on the first hand, to form the planar lens backside and, on the other hand, to open the silicon cavity. Nevertheless, silicon frames are then kept and thinned down to form well-controlled and auto-aligned spacers between the lenses. Subsequent accurate vertical assembly of the glass lens arrays is performed by anodic bonding. The latter ensures a high level of alignment both laterally and axially since no additional material is required. Thanks to polishing, the generated lens doublets are then as thin as several hundreds of microns and compatible with micro-opto-electro-systems (MOEMS) technologies since they are only made of glass and silicon. The generated optical module is then robust and provide improved optical performances. Indeed, theoretically, two stacked lenses with similar features and spherical profiles can be almost diffraction limited whereas a single lens characterized by the same numerical aperture than the doublet presents five times higher wavefront error. To demonstrate such assumption, we fabricated glass lens doublets and compared them to single lenses of equivalent focusing power. For similar illumination, the optical aberrations are significantly reduced.
Informing Automated Writing Evaluation Using the Lens of Genre: Two Studies
ERIC Educational Resources Information Center
Burstein, Jill; Elliot, Norbert; Molloy, Hillary
2016-01-01
Genre serves as a useful lens to investigate the range of evidence derived from automated writing evaluation (AWE). To support construct-relevant systems used for writing instruction and assessment, two investigations were conducted that focused on postsecondary writing requirements and faculty perceptions of student writing proficiency. Survey…
Laser Transmissometer, Installation, Alignment and Instruction Manual.
1978-07-01
detector lens LI, which focuses the energy onto detector Dl, a pyroelectric long wavelength detector. The S2 radiation is reflected by BS5 to lens L2 and...Instruction Manual for Series TWO-10 YAG-TWOTM Lasers (Serial 162 and Above) General Photonics Inc. Operating and Maintenance Manual Hughes Helion Neon
Restorative Practices: Graduate Students' Perspectives Seen through a Transformative Learning Lens
ERIC Educational Resources Information Center
Adamson, Craig W.
2012-01-01
This dissertation explores students' learning experiences in a newly accredited graduate school focused on Restorative Practices Theory, which enables people to restore and build community collectively. This exploration was conducted using a Transformative Adult Learning Theory lens in order to understand graduate students' perspectives regarding…
Role of Aquaporin 0 in lens biomechanics.
Sindhu Kumari, S; Gupta, Neha; Shiels, Alan; FitzGerald, Paul G; Menon, Anil G; Mathias, Richard T; Varadaraj, Kulandaiappan
2015-07-10
Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5(-/-)), AQP0 KO (heterozygous KO: AQP0(+/-); homozygous KO: AQP0(-/-); all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0(+/-) lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and together they help to confer fiber cell shape, architecture and integrity. To our knowledge, this is the first report identifying the involvement of an aquaporin in lens biomechanics. Since accommodation is required in human lenses for proper focusing, alteration in the adhesion and/or water channel functions of AQP0 could contribute to presbyopia. Copyright © 2015 Elsevier Inc. All rights reserved.
Aureole lidar: Design, operation, and comparison with in-situ measurements
NASA Astrophysics Data System (ADS)
Hooper, William P.; Jensen, D. R.
1992-07-01
In 1986, H. Berber and Hooper examined the signals that could be detected by an airborne lidar flying above the marine boundary layer (MBL). One signal (aureole) formed from laser light returned to the receiver after a reflect off the ocean and forward scatter off the aerosol particles appeared to be both detectable and related to the optical depth of the MBL. Now, research has been directed towards developing a practical instrument to measure the aureole and finding an algorithm to use the information. Unlike the lidar backscatter which typically requires a telescope with a narrow field of view (0.5 mrad), the aureole signal occurs over a wide field of view (50 mrad). To accommodate the totally different needs, a standard commercial Cassegrainian telescope was modified to yield a telescope with two focal planes. The secondary mirror was replaced by a lens, whose front surface was half silvered and curved to match the replaced mirror. Light reflecting off the lens focused behind the primary mirror. The back lens surface was curved to allow unreflected light to focus at the natural focus of the primary mirror. This focal plane which is behind the lens has a wide field of view. To calculate an extinction profile, the aureole optical depth estimate is combined with the lidar backscatter profile.
Aureole lidar: Design, operation, and comparison with in-situ measurements
NASA Technical Reports Server (NTRS)
Hooper, William P.; Jensen, D. R.
1992-01-01
In 1986, H. Berber and Hooper examined the signals that could be detected by an airborne lidar flying above the marine boundary layer (MBL). One signal (aureole) formed from laser light returned to the receiver after a reflect off the ocean and forward scatter off the aerosol particles appeared to be both detectable and related to the optical depth of the MBL. Now, research has been directed towards developing a practical instrument to measure the aureole and finding an algorithm to use the information. Unlike the lidar backscatter which typically requires a telescope with a narrow field of view (0.5 mrad), the aureole signal occurs over a wide field of view (50 mrad). To accommodate the totally different needs, a standard commercial Cassegrainian telescope was modified to yield a telescope with two focal planes. The secondary mirror was replaced by a lens, whose front surface was half silvered and curved to match the replaced mirror. Light reflecting off the lens focused behind the primary mirror. The back lens surface was curved to allow unreflected light to focus at the natural focus of the primary mirror. This focal plane which is behind the lens has a wide field of view. To calculate an extinction profile, the aureole optical depth estimate is combined with the lidar backscatter profile.
Acoustophoretic separation of airborne millimeter-size particles by a Fresnel lens.
Cicek, Ahmet; Korozlu, Nurettin; Adem Kaya, Olgun; Ulug, Bulent
2017-03-02
We numerically demonstrate acoustophoretic separation of spherical solid particles in air by means of an acoustic Fresnel lens. Beside gravitational and drag forces, freely-falling millimeter-size particles experience large acoustic radiation forces around the focus of the lens, where interplay of forces lead to differentiation of particle trajectories with respect to either size or material properties. Due to the strong acoustic field at the focus, radiation force can divert particles with source intensities significantly smaller than those required for acoustic levitation in a standing field. When the lens is designed to have a focal length of 100 mm at 25 kHz, finite-element method simulations reveal a sharp focus with a full-width at half-maximum of 0.5 wavelenghts and a field enhancement of 18 dB. Through numerical calculation of forces and simulation of particle trajectories, we demonstrate size-based separation of acrylic particles at a source sound pressure level of 153 dB such that particles with diameters larger than 0.5 mm are admitted into the central hole, whereas smaller particles are rejected. Besides, efficient separation of particles with similar acoustic properties such as polyethylene, polystyrene and acrylic particles of the same size is also demonstrated.
Acoustophoretic separation of airborne millimeter-size particles by a Fresnel lens
NASA Astrophysics Data System (ADS)
Cicek, Ahmet; Korozlu, Nurettin; Adem Kaya, Olgun; Ulug, Bulent
2017-03-01
We numerically demonstrate acoustophoretic separation of spherical solid particles in air by means of an acoustic Fresnel lens. Beside gravitational and drag forces, freely-falling millimeter-size particles experience large acoustic radiation forces around the focus of the lens, where interplay of forces lead to differentiation of particle trajectories with respect to either size or material properties. Due to the strong acoustic field at the focus, radiation force can divert particles with source intensities significantly smaller than those required for acoustic levitation in a standing field. When the lens is designed to have a focal length of 100 mm at 25 kHz, finite-element method simulations reveal a sharp focus with a full-width at half-maximum of 0.5 wavelenghts and a field enhancement of 18 dB. Through numerical calculation of forces and simulation of particle trajectories, we demonstrate size-based separation of acrylic particles at a source sound pressure level of 153 dB such that particles with diameters larger than 0.5 mm are admitted into the central hole, whereas smaller particles are rejected. Besides, efficient separation of particles with similar acoustic properties such as polyethylene, polystyrene and acrylic particles of the same size is also demonstrated.
Acoustophoretic separation of airborne millimeter-size particles by a Fresnel lens
Cicek, Ahmet; Korozlu, Nurettin; Adem Kaya, Olgun; Ulug, Bulent
2017-01-01
We numerically demonstrate acoustophoretic separation of spherical solid particles in air by means of an acoustic Fresnel lens. Beside gravitational and drag forces, freely-falling millimeter-size particles experience large acoustic radiation forces around the focus of the lens, where interplay of forces lead to differentiation of particle trajectories with respect to either size or material properties. Due to the strong acoustic field at the focus, radiation force can divert particles with source intensities significantly smaller than those required for acoustic levitation in a standing field. When the lens is designed to have a focal length of 100 mm at 25 kHz, finite-element method simulations reveal a sharp focus with a full-width at half-maximum of 0.5 wavelenghts and a field enhancement of 18 dB. Through numerical calculation of forces and simulation of particle trajectories, we demonstrate size-based separation of acrylic particles at a source sound pressure level of 153 dB such that particles with diameters larger than 0.5 mm are admitted into the central hole, whereas smaller particles are rejected. Besides, efficient separation of particles with similar acoustic properties such as polyethylene, polystyrene and acrylic particles of the same size is also demonstrated. PMID:28252033
The small-animal radiation research platform (SARRP): dosimetry of a focused lens system.
Deng, Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang, Licai; Wong, John
2007-05-21
A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/-5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.
Shen, Xin; Javidi, Bahram
2018-03-01
We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.
Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane
2015-01-01
Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients' satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material. Copyright © 2014. Published by Elsevier Espana.
The "Best Worst" Field Optimization and Focusing
NASA Technical Reports Server (NTRS)
Vaughnn, David; Moore, Ken; Bock, Noah; Zhou, Wei; Ming, Liang; Wilson, Mark
2008-01-01
A simple algorithm for optimizing and focusing lens designs is presented. The goal of the algorithm is to simultaneously create the best and most uniform image quality over the field of view. Rather than relatively weighting multiple field points, only the image quality from the worst field point is considered. When optimizing a lens design, iterations are made to make this worst field point better until such a time as a different field point becomes worse. The same technique is used to determine focus position. The algorithm works with all the various image quality metrics. It works with both symmetrical and asymmetrical systems. It works with theoretical models and real hardware.
Photographic zoom fisheye lens design for DSLR cameras
NASA Astrophysics Data System (ADS)
Yan, Yufeng; Sasian, Jose
2017-09-01
Photographic fisheye lenses with fixed focal length for cameras with different sensor formats have been well developed for decades. However, photographic fisheye lenses with variable focal length are rare on the market due in part to the greater design difficulty. This paper presents a large aperture zoom fisheye lens for DSLR cameras that produces both circular and diagonal fisheye imaging for 35-mm sensors and diagonal fisheye imaging for APS-C sensors. The history and optical characteristics of fisheye lenses are briefly reviewed. Then, a 9.2- to 16.1-mm F/2.8 to F/3.5 zoom fisheye lens design is presented, including the design approach and aberration control. Image quality and tolerance performance analysis for this lens are also presented.
The effect of variably tinted spectacle lenses on visual performance in cataract subjects.
Naidu, Srilata; Lee, Jason E; Holopigian, Karen; Seiple, William H; Greenstein, Vivienne C; Stenson, Susan M
2003-01-01
A body of clinical and laboratory evidence suggests that tinted spectacle lenses may have an effect on visual performance. The aim of this study was to quantify the effects of spectacle lens tint on the visual performance of 25 subjects with cataracts. Cataracts were scored based on best-corrected acuity and by comparison with the Lens Opacity Classification System (LOCS III) plates. Visual performance was assessed by measuring contrast sensitivity with and without glare (Morphonome software version 4.0). The effect of gray, brown, yellow, green and purple tinting was evaluated. All subjects demonstrated an increase in contrast thresholds under glare conditions regardless of lens tint. However, brown and yellow lens tints resulted in the least amount of contrast threshold increase. Gray lens tint resulted in the largest contrast threshold increase. Individuals with lenticular changes may benefit from brown or yellow spectacle lenses under glare conditions.
Continuously variable focal length lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, Bernhard W; Chollet, Matthieu C
2013-12-17
A material preferably in crystal form having a low atomic number such as beryllium (Z=4) provides for the focusing of x-rays in a continuously variable manner. The material is provided with plural spaced curvilinear, optically matched slots and/or recesses through which an x-ray beam is directed. The focal length of the material may be decreased or increased by increasing or decreasing, respectively, the number of slots (or recesses) through which the x-ray beam is directed, while fine tuning of the focal length is accomplished by rotation of the material so as to change the path length of the x-ray beammore » through the aligned cylindrical slows. X-ray analysis of a fixed point in a solid material may be performed by scanning the energy of the x-ray beam while rotating the material to maintain the beam's focal point at a fixed point in the specimen undergoing analysis.« less
NASA Astrophysics Data System (ADS)
Angénieux, J. P. L.
1987-06-01
Modern objective lenses for cinematography, television or photography, and particularly zoom lenses, are composed of several groups of lenses which are axially displaced during zooming and/or focusing. The number of these groups has increased recently as well as the complexity of their relative movements and functions. In this paper, we give a short history of zooming and focusing techniques ; we discuss the inconvenience of traditional solutions. We then introduce the concept of bidimensional law. We propose a systematic classification of possible lens-types according to the 4 possible types of group. We finally present a few types of lenses in the form of truth tables and parametered diagrams explaining which groups move and how during focusing and/or zooming.
DOE Office of Scientific and Technical Information (OSTI.GOV)
S., Juan Manuel Franco; Cywiak, Moises; Cywiak, David
2015-06-24
A homodyne profiler is used for recording the intensity distribution of focused non-truncated Gaussian beams. The spatial distributions are obtained at planes in the vicinity of the back-focal plane of a focusing lens placed at different distances from a He–Ne laser beam with a Gaussian intensity profile. Comparisons of the experimental data with those obtained from the analytical equations for an ideal focusing lens allow us to propose formulae to fine-tune the quadratic term in the Fresnel Gaussian shape invariant at each interface of the propagated field. Furthermore, we give analytical expressions to calculate adequately the propagation of the fieldmore » through an optical system.« less
Asymptomatic snowflake degeneration in a polymethyl methacrylate (PMMA) intraocular lens implant.
Tan, Lee T; Shuttleworth, Garry N
2008-01-01
Snowflake degeneration is a late complication of polymethyl methacrylate (PMMA) intraocular lens implants. We report a case of asymptomatic advanced snowflake opacification presenting 13 years after implantation who maintained a visual acuity of 6/6. This report serves to illustrate the variability of the clinical effects of snowflake degeneration, which do not necessarily correlate with slit-lamp appearances.
Propagation of a cosh-Gaussian beam through an optical system in turbulent atmosphere.
Chu, Xiuxiang
2007-12-24
The propagation of a cosh-Gaussian beam through an arbitrary ABCD optical system in turbulent atmosphere has been investigated. The analytical expressions for the average intensity at any receiver plane are obtained. As an elementary example, the average intensity and its radius at the image plane of a cosh-Gaussian beam through a thin lens are studied. To show the effects of a lens on the average intensity and the intensity radius of the laser beam in turbulent atmosphere, the properties of a collimated cosh-Gaussian beam and a focused cosh-Gaussian beam for direct propagation in turbulent atmosphere are studied and numerically calculated. The average intensity profiles of a cosh-Gaussian beam through a lens can have a shape similar to that of the initial beam for a longer propagation distance than that of a collimated cosh-Gaussian beam for direct propagation. With the increment in the propagation distance, the average intensity radius at the image plane of a cosh-Gaussian beam through a thin lens will be smaller than that at the focal plane of a focused cosh-Gaussian beam for direct propagation. Meanwhile, the intensity distributions at the image plane of a cosh-Gaussian beam through a lens with different w(0) and Omega(0) are also studied.
Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes.
Schaeffel, Frank
2008-05-01
Tilt and decentration of the natural crystalline lens affect optical quality of the foveal image. However, little is known about the distributions of these variables in healthy subjects with phakic eyes and about their correlations in both eyes. A simple, portable, easy-to-use, and partially automated device was developed to study lens tilt and decentration in both eyes of 11 healthy subjects with phakic eyes. The first, third, and fourth Purkinje images (P1, P3, P4) were visualized using a single infrared (IR) light-emitting diode (LED), a planar lens (F = 85 mm; f/number of 1.4), and an infrared sensitive analog video camera. Software was developed to mark pupil edges and positions of P1, P4, and P3 with the cursor of the computer mouse, for three different gaze positions, and an automated regression analysis determined the gaze position that superimposed the third and fourth Purkinje images, the gaze direction for which the lens was oriented perpendicularly to the axis of the IR LED. In this position, lens decentration was determined as the linear distance of the superimposed P3/P4 positions from the pupil center. Contrary to previous approaches, a short initial fixation of a green LED with known angular position calibrated the device as a gaze tracker, and no further positional information was necessary on fixation targets. Horizontal and vertical kappa, horizontal and vertical lens tilt, and vertical lens decentration were highly correlated in both eyes of the subjects, whereas horizontal decentration of the lens was not. There was a large variability of kappa (average horizontal kappa -1.63 degrees +/- 1.77 degrees [left eyes] and +2.07 degrees +/- 2.68 degrees [right eyes]; average vertical kappa +2.52 degrees +/- 1.30 degrees [left eyes] and +2.77 degrees +/- 1.65 degrees [right eyes]). Standard deviation from three repeated measurements ranged from 0.28 degrees to 0.51 degrees for kappa, 0.36 degrees to 0.91 degrees for horizontal lens tilt, and 0.36 degrees to 0.48 degrees for vertical lens tilt. Decentration was measured with standard deviations ranging from 0.02 mm to 0.05 mm. All lenses were found tilted to the temporal side with respect to the fixation axis (on average by 4.6 degrees ). They were also decentered downward with respect to the pupil center by approximately 0.3 mm. Lens tilts and positions could be conveniently measured with the described portable device, a video camera with a large lens. That the lenses were tilted to the temporal side in both eyes, even if corrected for kappa, was unexpected. That they were displaced downward with respect to the pupil center could be related to gravity.
Multistage polymeric lens structure in silica-waveguides for photonic functional circuits
NASA Astrophysics Data System (ADS)
Tate, Atsushi; Suzuki, Takanori; Tsuda, Hiroyuki
2005-04-01
A waveguide lens composed of multistage polymer-filled thin grooves in a silica planar lightwave circuit (PLC) is proposed and the low-loss structure is designed. Both an imaging optical system and a Fourier-Transform optical system can be configured in a PLC by use of a waveguide lens. It makes a PLC functional and its design flexible. Moreover, a focal length of a lens is tunable with large thermo-optic effect of the polymer. A concatenated lens is formed to attain a desirable focal length with low-loss. The thickness of each lens and the spacing are about 10-50 microns. The simulation showed that the radiation loss of the light propagate through 20-stage grooves filled with a polymer was only 0.868 dB when the refractive index of the polymer was 1.57, the groove width was 30 microns, and the spacing between adjacent grooves was 15 microns. For example, the single lens structure that the center thickness is 30 microns, the diameter is 300 microns, and the refractive index of the polymer was 1.57, have a focal length of 4600 microns. The focal length of 450 microns can be obtained with 20-stage concatenated lens structure. The larger numerical aperture can be realized with a polymer of higher refractive index. We have applied the concatenated lens structure to various photonic circuits including optical couplers, a variable optical attenuator.
Clinical Detection of Pre-Cataractous Lens Protein Changes using Dynamic Light Scattering
Datiles, Manuel B.; Ansari, Rafat R.; Suh, Kwang I.; Vitale, Susan; Reed, George F.; Zigler, J. Samuel; Ferris., Frederick L.
2008-01-01
Purpose To use Dynamic Light Scattering (DLS) to clinically assess early pre-cataractous lens protein changes. Methods We performed a cross sectional study in 380 eyes of 235 subjects aged 7–86 years with AREDS clinical lens nuclear grades ranging from 0–3.8. A DLS device was used to assess α-crystallin, a molecular chaperone protein shown to bind other damaged lens proteins, preventing their aggregation. The outcome measure was the α-crystallin index (ACI), a measure of unbound α-crystallin in each lens. The association of ACI with increasing nuclear opacity and aging was determined. Results There was a significant decrease in ACI associated with increasing grades of lens nuclear opacity (p<0.0001). There are significant losses of α-crystallin even in clinically clear lenses associated with aging (p<0.0001). The standard error of measurement was 3%. Conclusions DLS clinically detects loss of α-crystallin proteins even in clinically clear lenses. ACI measurements may be useful in identifying patients at high risk for developing cataract, and as an outcome variable in clinical lens studies. Clinical Relevance Our studies suggest that the ACI may be a useful measure of the protective α-crystallin molecular chaperone reserve present in a lens, analogous to creatinine clearance in estimating renal function reserve. PMID:19064850
Designs for optimizing depth of focus and spot size for UV laser ablation
NASA Astrophysics Data System (ADS)
Wei, An-Chi; Sze, Jyh-Rou; Chern, Jyh-Long
2010-11-01
The proposed optical systems are designed for extending the depths of foci (DOF) of UV lasers, which can be exploited in the laser-ablation technologies, such as laser machining and lithography. The designed systems are commonly constructed by an optical module that has at least one aspherical surface. Two configurations of optical module, lens-only and lens-reflector, are presented with the designs of 2-lens and 1-lens-1-reflector demonstrated by commercially optical software. Compared with conventional DOF-enhanced systems, which required the chromatic aberration lenses and the light sources with multiple wavelengths, the proposed designs are adapted to the single-wavelength systems, leading to more economical and efficient systems.
de Castro, Alberto; Ortiz, Sergio; Gambra, Enrique; Siedlecki, Damian; Marcos, Susana
2010-10-11
We present an optimization method to retrieve the gradient index (GRIN) distribution of the in-vitro crystalline lens from optical path difference data extracted from OCT images. Three-dimensional OCT images of the crystalline lens are obtained in two orientations (with the anterior surface up and posterior surface up), allowing to obtain the lens geometry. The GRIN reconstruction method is based on a genetic algorithm that searches for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens. Computer simulations showed that, for noise of 5 μm in the surface elevations, the GRIN is recovered with an accuracy of 0.003 and 0.010 in the refractive indices of the nucleus and surface of the lens, respectively. The method was applied to retrieve three-dimensionally the GRIN of a porcine crystalline lens in vitro. We found a refractive index ranging from 1.362 in the surface to 1.443 in the nucleus of the lens, an axial exponential decay of the GRIN profile of 2.62 and a meridional exponential decay ranging from 3.56 to 5.18. The effect of GRIN on the aberrations of the lens also studied. The estimated spherical aberration of the measured porcine lens was 2.87 μm assuming a homogenous equivalent refractive index, and the presence of GRIN shifted the spherical aberration toward negative values (-0.97 μm), for a 6-mm pupil.
In Vivo Brillouin Analysis of the Aging Crystalline Lens
Besner, Sebastien; Scarcelli, Giuliano; Pineda, Roberto; Yun, Seok-Hyun
2016-01-01
Purpose To analyze the age dependence of the longitudinal modulus of the crystalline lens in vivo using Brillouin scattering data in healthy subjects. Methods Brillouin scans were performed along the crystalline lens in 56 eyes from 30 healthy subjects aged from 19 to 63 years. Longitudinal elastic modulus was acquired along the sagittal axis of the lens with a transverse and axial resolution of 4 and 60 μm, respectively. The relative lens stiffness was computed, and correlations with age were analyzed. Results Brillouin axial profiles revealed nonuniform longitudinal modulus within the lens, increasing from a softer periphery toward a stiffer central plateau at all ages. The longitudinal modulus at the central plateau showed no age dependence in a range of 19 to 45 years and a slight decrease with age from 45 to 63 years. A significant intersubject variability was observed in an age-matched analysis. Importantly, the extent of the central stiff plateau region increased steadily over age from 19 to 63 years. The slope of change in Brillouin modulus in the peripheral regions were nearly age-invariant. Conclusions The adult human lens showed no measurable age-related increase in the peak longitudinal modulus. The expansion of the stiff central region of the lens is likely to be the major contributing factor to age-related lens stiffening. Brillouin microscopy may be useful in characterizing the crystalline lens for the optimization of surgical or pharmacological treatments aimed at restoring accommodative power. PMID:27699407
NASA Astrophysics Data System (ADS)
Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.
2014-09-01
Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.
Portraying Monsters: Framing School Bullying through a Macro Lens
ERIC Educational Resources Information Center
Horton, Paul
2016-01-01
This article critically considers the discourse on school bullying through the conceptual framework of lenses and argues that a macro lens has been utilised by school bullying researchers to bring into focus the characteristics of the individuals involved and the types of actions used. By considering earlier understandings of bullying, the article…
ERIC Educational Resources Information Center
Schill, Bethany; Howell, Linda
2011-01-01
A major part of developing concept-based instruction is the use of an overarching idea to provide a conceptual lens through which students view the content of a particular subject. By using a conceptual lens to focus learning, students think at a much deeper level about the content and its facts (Erickson 2007). Therefore, the authors collaborated…
Re-Reading Dewey through a Feminist Lens
ERIC Educational Resources Information Center
Vorsino, Mary
2015-01-01
In this review, Mary Vorsino writes that she is interested in keeping the potential influences of women pragmatists of Dewey's day in mind while presenting modern feminist re readings of Dewey. She wishes to construct a narrowly-focused and succinct literature review of thinkers who have donned a feminist lens to analyze Dewey's approaches to…
Positronium Annihilation Gamma Ray Laser
2009-07-01
polarized light since the reflection from the surface of a pellin broca prism mounted at Brewsters angle was nearly diminished, so as a result a fair...19 Figure 10 Simion simulation of the grid lens focus. The initial...21 Figure 12 Image simulation of the bunched beam before and after going through the grid lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seiboth, Frank; Wittwer, Felix; Scholz, Maria
Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with σ¯ = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without priormore » lens characterization but simply based on the derived lens deformation. As a result, the performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.« less
A novel collinear optical system with annulus mirrors for holographic disc driver
NASA Astrophysics Data System (ADS)
Wang, Ye
2008-12-01
This paper focus on a novel collinear lens system with annulus mirrors for holographic disc driver, both information beam and reference beam are use same laser beam. The expanded and parallel laser beam, center part of it as the information beam then through Fourier transform lens, the beam around center part as a reference beam. On this axis, the ring reference beam reflected by two annulus shaped mirrors, then became a convergent beam, together with the information beam which through the first Fourier transform lens then produce holographic pattern to be write into the holographic disc behind of them, this lens system with two mirrors made the angle between information beam and reference beam more wide, can improved the multiplex level of holographic storage. Pair of Fourier transform lens with advance performance is designed in this paper.
Advances in lens implant technology
Kampik, Anselm; Dexl, Alois K.; Zimmermann, Nicole; Glasser, Adrian; Baumeister, Martin; Kohnen, Thomas
2013-01-01
Cataract surgery is one of the oldest and the most frequent outpatient clinic operations in medicine performed worldwide. The clouded human crystalline lens is replaced by an artificial intraocular lens implanted into the capsular bag. During the last six decades, cataract surgery has undergone rapid development from a traumatic, manual surgical procedure with implantation of a simple lens to a minimally invasive intervention increasingly assisted by high technology and a broad variety of implants customized for each patient’s individual requirements. This review discusses the major advances in this field and focuses on the main challenge remaining – the treatment of presbyopia. The demand for correction of presbyopia is increasing, reflecting the global growth of the ageing population. Pearls and pitfalls of currently applied methods to correct presbyopia and different approaches under investigation, both in lens implant technology and in surgical technology, are discussed. PMID:23413369
Far-field characteristics of the square grooved-dielectric lens antenna for the terahertz band.
Pan, Wu; Zeng, Wei
2016-09-10
In order to improve the gain and directionality of a terahertz antenna, a square grooved-dielectric lens antenna based on a Fresnel zone plate is proposed. First, a diagonal horn, which is adopted as the primary feed antenna, is designed. Then, the far-field characteristics of the lens antenna are studied by using Fresnel-Kirchhoff diffraction theory and the paraxial approximation. The effects of the full-wave period, the focus diameter ratio, the subregion, and the dielectric substrate thickness on radiation characteristics are studied. The experimental results show that the proposed lens antenna has axisymmetric radiation patterns. The gain is over 26.1 dB, and the 3 dB main lobe beam width is lower than 5.6° across the operation band. The proposed lens antenna is qualified for applications in terahertz wireless communication systems.
Xie, Dan; Zhang, Honghai; Shu, Xiayun; Xiao, Junfeng
2012-07-02
The paper reports an effective method to fabricate micro-lens arrays with the ultraviolet-curable polymer, using an original pneumatically diaphragm-driven drop-on-demand inkjet system. An array of plano convex micro-lenses can be formed on the glass substrate due to surface tension and hydrophobic effect. The micro-lens arrays have uniform focusing function, smooth and real planar surface. The fabrication process showed good repeatability as well, fifty micro-lenses randomly selected form 9 × 9 miro-lens array with an average diameter of 333.28μm showed 1.1% variations. Also, the focal length, the surface roughness and optical property of the fabricated micro-lenses are measured, analyzed and proved satisfactory. The technique shows great potential for fabricating polymer micro-lens arrays with high flexibility, simple technological process and low production cost.
Artificial dielectric stepped-refractive-index lens for the terahertz region.
Hernandez-Serrano, A I; Mendis, Rajind; Reichel, Kimberly S; Zhang, Wei; Castro-Camus, E; Mittleman, Daniel M
2018-02-05
In this paper we theoretically and experimentally demonstrate a stepped-refractive-index convergent lens made of a parallel stack of metallic plates for terahertz frequencies based on artificial dielectrics. The lens consist of a non-uniformly spaced stack of metallic plates, forming a mirror-symmetric array of parallel-plate waveguides (PPWGs). The operation of the device is based on the TE 1 mode of the PPWG. The effective refractive index of the TE 1 mode is a function of the frequency of operation and the spacing between the plates of the PPWG. By varying the spacing between the plates, we can modify the local refractive index of the structure in every individual PPWG that constitutes the lens producing a stepped refractive index profile across the multi stack structure. The theoretical and experimental results show that this structure is capable of focusing a 1 cm diameter beam to a line focus of less than 4 mm for the design frequency of 0.18 THz. This structure shows that this artificial-dielectric concept is an important technology for the fabrication of next generation terahertz devices.
Relationship between changes in crystalline lens shape and axial elongation in young children.
Ishii, Kotaro; Yamanari, Masahiro; Iwata, Hiroyoshi; Yasuno, Yoshiaki; Oshika, Tetsuro
2013-01-28
To evaluate the relationship between changes in crystalline lens shape and axial elongation during growth in young children. Twenty-five patients (age: 1 month to 6 years) who underwent head magnetic resonance imaging (MRI) were included in the analysis. Refractive error was measured with an autorefractor in 22 patients. Crystalline lens dimensions and axial length (AL) were obtained from the MR images. The radius of curvature and asphericity of the crystalline lens were measured using reconstructed MR images. Crystalline lens shape and eyeball shape were numerically expressed by elliptic Fourier descriptors (EFDs) on the basis of MR images. The contours of the crystalline lens and eyeball were evaluated by principal component analysis of the EFDs. The average anterior and posterior radii of curvature were 6.21 mm (range across ages from 3.89-7.26 mm) and -4.81 mm (range across ages from -2.93 to -5.67 mm). These were closely correlated with age by logarithmic analysis. The first principal component (PC1) of the crystalline lens explained 89.15% of the total variance in lens shape, and it was also significantly correlated with age (Pearson's r = 0.648, P < 0.001) and AL (r = 0.847, P < 0.001). In the multiple linear regression analysis in which AL was a dependent variable, only the PC1 of the crystalline lens was associated with AL. Axial elongation is related to the entire contour of the crystalline lens. This result shows that axial elongation progresses in parallel to change in the crystalline lens shape.
Heterochromatic Flicker Photometry for Objective Lens Density Quantification.
Najjar, Raymond P; Teikari, Petteri; Cornut, Pierre-Loïc; Knoblauch, Kenneth; Cooper, Howard M; Gronfier, Claude
2016-03-01
Although several methods have been proposed to evaluate lens transmittance, to date there is no consensual in vivo approach in clinical practice. The aim of this study was to compare ocular lens density and transmittance measurements obtained by an improved psychophysical scotopic heterochromatic flicker photometry (sHFP) technique to the results obtained by three other measures: a psychophysical threshold technique, a Scheimpflug imaging technique, and a clinical assessment using a validated subjective scale. Forty-three subjects (18 young, 9 middle aged, and 16 older) were included in the study. Individual lens densities were measured and transmittance curves were derived from sHFP indexes. Ocular lens densities were compared across methods by using linear regression analysis. The four approaches showed a quadratic increase in lens opacification with age. The sHFP technique revealed that transmittance decreased with age over the entire visual spectrum. This decrease was particularly pronounced between young and older participants in the short (53.03% decrease in the 400-500 nm range) wavelength regions of the light spectrum. Lens density derived from sHFP highly correlated with the values obtained with the other approaches. Compared to other objective measures, sHFP also showed the lowest variability and the best fit with a quadratic trend (r2 = 0.71) of lens density increase as a function of age. The sHFP technique offers a practical, reliable, and accurate method to measure lens density in vivo and predict lens transmittance over the visible spectrum. An accurate quantification of lens transmittance should be obtained in clinical practice, but also in research in visual and nonvisual photoreception.
Compliance factors associated with contact lens-related dry eye.
Ramamoorthy, Padmapriya; Nichols, Jason Jay
2014-01-01
To determine if compliance factors are associated with contact lens-related dry eye (CLDE). The data were derived from subject responses to a compliance survey administered in a cross-sectional study including 100 healthy, daily (nonovernight), experienced soft contact lens wearers (50 normal and 50 with CLDE). Classification into normal or CLDE groups was based on Contact Lens Dry Eye Questionnaire scores, tear breakup time, and 2 hours difference between total and comfortable daily lens wear hours. The compliance survey queried aspects of lens care, rub and rinse practices, lens and lens case replacement frequency, solution replacement, and sleeping with lenses. Statistical analysis of the data was performed using unpaired T tests, χ, and Fisher exact tests as applicable. The average age of all subjects was 24.8±4.4 years, and 60% were women. Overall compliance rates were low for several variables including recommended replacement of contact lenses (53%), rub and rinse practices (69% and 45%, respectively), care solution topping-off (80%), and washing hands before handling lenses (48%). However, almost no compliance factors were associated with CLDE status, with the exception of perceived ease or difficulty with lens care, which was rated as more difficult by the CLDE group (P=0.004). Overall compliance rates with contact lens care practices are very low, highlighting the need for more effective methods of patient education regarding contact lens care and compliance. However, almost no compliance factors were found to be associated with CLDE. Factors other than compliance likely play a bigger role in CLDE.
NASA Astrophysics Data System (ADS)
Kakarenko, K.; Ducin, I.; Jaroszewicz, Z.; Kołodziejczyk, A.; Petelczyc, K.; Stompor, A.; Sypek, M.
2015-04-01
Light Sword Lens (LSL), i.e., an optical element with extended depth of focus (EDOF) characterized by angular modulation of the optical power in its conventional form is characterized by a linear relationship between the optical power and the angular coordinate of the corresponding angular lens sector. This dependence may be manipulated in function of the required design needs. In the present communicate this additional degree of freedom of design is used for elimination of the LSL shape discontinuity.
Elasticity of the eye's crystalline lens: A Brillouin light scattering study.
NASA Astrophysics Data System (ADS)
Bailey, S.; Gump, J.; Sooryakumar, R.; Jayaprakash, C.; Venkiteshwar, M. S.; Bullimore, M.; Twa, M.
2009-03-01
Focusing the eye on a near object results in an increase in its optical power brought about by contraction of the ciliary muscles and an increase in the lens surface curvature. Distant vision occurs when the muscular force flattens the lens. Central to the ability of the lens to alter shape are its mechanical properties. Thus, given that hardening of the lens would impede deformation and reduce its ability to undergo the changes required for accommodation, a noninvasive approach to measure the elastic properties of the lens is valuable. We present results of Brillouin scattering from bovine and human lenses (from the organ donor program at The Ohio State University) that measure their high frequency acoustic response. These measurements are conducted with a few milli-watts of laser power and, in the case of bovine lenses, from entire intact eye globes, allow the stiffness of the lens to be mapped across its cross-section. The results will be compared to values of the shear- and bulk-moduli determined from other techniques and the implications of differences in these moduli discussed.
Energy Efficiency of a New Trifocal Intraocular Lens
NASA Astrophysics Data System (ADS)
Vega, F.; Alba-Bueno, F.; Millán, M. S.
2014-01-01
The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.
Three-dimensional OCT based guinea pig eye model: relating morphology and optics.
Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Revuelta, Luis; McFadden, Sally A; Marcos, Susana
2017-04-01
Custom Spectral Optical Coherence Tomography (SOCT) provided with automatic quantification and distortion correction algorithms was used to measure the 3-D morphology in guinea pig eyes (n = 8, 30 days; n = 5, 40 days). Animals were measured awake in vivo under cyclopegia. Measurements showed low intraocular variability (<4% in corneal and anterior lens radii and <8% in the posterior lens radii, <1% interocular distances). The repeatability of the surface elevation was less than 2 µm. Surface astigmatism was the individual dominant term in all surfaces. Higher-order RMS surface elevation was largest in the posterior lens. Individual surface elevation Zernike terms correlated significantly across corneal and anterior lens surfaces. Higher-order-aberrations (except spherical aberration) were comparable with those predicted by OCT-based eye models.
An adaptive liquid microlens driven by a ferrofluidic transducer
NASA Astrophysics Data System (ADS)
Xiao, Wenjia; Hardt, Steffen
2010-05-01
Ferrofluids behave superparamagnetically and can be manipulated by external magnetic fields, providing numerous applications in microfluidic systems. In this paper, an adaptive liquid microlens driven by a ferrofluidic actuator is presented. The microlens consists of a cylindrical well filled with a lens liquid connected to a microchannel containing a ferrofluid plug. When the ferrofluid plug is moved back and forth by an external magnetic field, the lens liquid is displaced, forming a liquid lens with an adaptive focus in the cylindrical well. The focal length of the lens can be changed from infinity to the scale of the radius of the cylindrical well, leading to a high optical power compared to conventional liquid lenses utilizing liquid crystals or electrowetting. The lens curvature is reversibly tunable without hysteresis when the ferrofluid plug moves with a speed below a specific threshold value. The lens can be acted on by a magnetic field of about 100 mT which can be generated by microcoils requiring much lower voltages than the electrowetting principle.
NASA Technical Reports Server (NTRS)
Chylack, Leo T.; Peterson, Leif E.; Feiveson, Alan H.; Wear, Mary; Manuel, F. Keith
2007-01-01
The NASA Study of Cataract in Astronauts (NASCA) is a five-year, multi-centered, investigation of lens opacification in populations of U.S. astronauts, military pilots, and ground-based (nonaviator) comparison participants. For astronauts, the explanatory variable of most interest is radiation exposure during space flight, however to properly evaluate its effect, the secondary effects of age, nutrition, general health, solar ocular exposure, and other confounding variables encountered in non-space flight must also be considered. NASCA contains an initial baseline, cross-sectional objective assessment of the severity of cortical (C), nuclear (N), and posterior subcapsular (PSC) lens opacification, and annual follow-on assessments of severity and progression of these opacities in the population of astronauts and in participants sampled from populations of military pilots and ground-based exposure controls. From these data, NASCA will estimate the degree to which space radiation affects lens opacification for astronauts and how the overall risks of each cataract type for astronauts compared with those of the other exposure control groups after adjusting for differences in age and other explanatory variables.
Sweatt, William C.; Gill, David D.
2007-10-23
An apposition microoptical compound lens comprises a plurality of lenslets arrayed around a segment of a hollow, three-dimensional optical shell. The lenslets collect light from an object and focus the light rays onto the concentric, curved front surface of a coherent fiber bundle. The fiber bundle transports the light rays to a planar detector, forming a plurality of sub-images that can be reconstructed as a full image. The microoptical compound lens can have a small size (millimeters), wide field of view (up to 180.degree.), and adequate resolution for object recognition and tracking.
Focusing and directional beaming effects of airborne sound through a planar lens with zigzag slits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Kun; Qiu, Chunyin, E-mail: cyqiu@whu.edu.cn; Lu, Jiuyang
2015-01-14
Based on the Huygens-Fresnel principle, we design a planar lens to efficiently realize the interconversion between the point-like sound source and Gaussian beam in ambient air. The lens is constructed by a planar plate perforated elaborately with a nonuniform array of zigzag slits, where the slit exits act as subwavelength-sized secondary sources carrying desired sound responses. The experiments operated at audible regime agree well with the theoretical predictions. This compact device could be useful in daily life applications, such as for medical and detection purposes.
Extending the depth of field in a fixed focus lens using axial colour
NASA Astrophysics Data System (ADS)
Fitzgerald, Niamh; Dainty, Christopher; Goncharov, Alexander V.
2017-11-01
We propose a method of extending the depth of field (EDOF) of conventional lenses for a low cost iris recognition front-facing smartphone camera. Longitudinal chromatic aberration (LCA) can be induced in the lens by means of dual wavelength illumination. The EDOF region is then constructed from the sum of the adjacent depths of field from each wavelength illumination. The lens parameters can be found analytically with paraxial raytracing. The extended depth of field is dependant on the glass chosen and position of the near object point.
Design of multisegmented freeform lens for LED fishing/working lamp with high efficiency.
Lai, Min-Feng; Anh, Nguyen Doan Quoc; Gao, Jia-Zhi; Ma, Hsin-Yi; Lee, Hsiao-Yi
2015-10-01
A novel LED fishing/working light is proposed to enhance the lighting efficiency of a fishing boat. The study is focused on the freeform secondary lens design so as to create a lamp that attracts fish and sheds light on the deck for the crew's work. The experimental results show that the proposed multisegmented freeform lens can deliver the proposed aim, giving 3 times as much illuminating power as the traditional high-intensity discharge fishing lamp does with the same input of electrical power.
Saw-tooth refractive lens for high energy x-ray focusing
NASA Astrophysics Data System (ADS)
Antimonov, Mikhail A.; Khounsary, Ali M.
2014-09-01
Saw-tooth refractive lens (SRL) provides a comparatively attractive option for X-ray focusing. An SRL assembly consists of two parts, each with an array of triangular structures (prisms), set tilted symmetrically with respect to the incoming beam. Its main advantage is a simple, continuous tunability in energy and focal length. SRLs can be used for both long and short focal length focusing. Long focal distance focusing of an SRL can accurately be predicted using simple analytical relations. However, the focus size at short focal distances focusing may deviate appreciably from the expected demagnified source size when: (1) the length of the SRL is comparable with the focusing distance, (2) the incident beam is not monochromatic, and (3) and the distance between adjacent prism tips, the tip step, is large . The first factor was considered in a previous work while the other two are addressed is this paper. This preliminary work is aimed at a better understanding of the SRL lenses for focusing an undulator beamline at the Advanced Photon Source (APS).
New analysis strategies for micro aspheric lens metrology
NASA Astrophysics Data System (ADS)
Gugsa, Solomon Abebe
Effective characterization of an aspheric micro lens is critical for understanding and improving processing in micro-optic manufacturing. Since most microlenses are plano-convex, where the convex geometry is a conic surface, current practice is often limited to obtaining an estimate of the lens conic constant, which average out the surface geometry that departs from an exact conic surface and any addition surface irregularities. We have developed a comprehensive approach of estimating the best fit conic and its uncertainty, and in addition propose an alternative analysis that focuses on surface errors rather than best-fit conic constant. We describe our new analysis strategy based on the two most dominant micro lens metrology methods in use today, namely, scanning white light interferometry (SWLI) and phase shifting interferometry (PSI). We estimate several parameters from the measurement. The major uncertainty contributors for SWLI are the estimates of base radius of curvature, the aperture of the lens, the sag of the lens, noise in the measurement, and the center of the lens. In the case of PSI the dominant uncertainty contributors are noise in the measurement, the radius of curvature, and the aperture. Our best-fit conic procedure uses least squares minimization to extract a best-fit conic value, which is then subjected to a Monte Carlo analysis to capture combined uncertainty. In our surface errors analysis procedure, we consider the surface errors as the difference between the measured geometry and the best-fit conic surface or as the difference between the measured geometry and the design specification for the lens. We focus on a Zernike polynomial description of the surface error, and again a Monte Carlo analysis is used to estimate a combined uncertainty, which in this case is an uncertainty for each Zernike coefficient. Our approach also allows us to investigate the effect of individual uncertainty parameters and measurement noise on both the best-fit conic constant analysis and the surface errors analysis, and compare the individual contributions to the overall uncertainty.
Barreda, F.-A.; Nicolas, C.; Sirven, J.-B.; Ouf, F.-X.; Lacour, J.-L.; Robert, E.; Benkoula, S.; Yon, J.; Miron, C.; Sublemontier, O.
2015-01-01
The Laser-Induced Breakdown Detection technique (LIBD) was adapted to achieve fast in-situ characterization of nanoparticle beams focused under vacuum by an aerodynamic lens. The method employs a tightly focused, 21 μm, scanning laser microprobe which generates a local plasma induced by the laser interaction with a single particle. A counting mode optical detection allows the achievement of 2D mappings of the nanoparticle beams with a reduced analysis time thanks to the use of a high repetition rate infrared pulsed laser. As an example, the results obtained with Tryptophan nanoparticles are presented and the advantages of this method over existing ones are discussed. PMID:26498694
Adaptation to the edge of chaos in a self-starting Kerr-lens mode-locked laser
NASA Astrophysics Data System (ADS)
Hsu, C. C.; Lin, J. H.; Hsieh, W. F.
2009-08-01
We experimentally and numerically demonstrated that self-focusing acts as a slow-varying control parameter that suppresses the transient chaos to reach a stable mode-locking (ML) state in a self-starting Kerr-lens mode-locked Ti:sapphire laser without external modulation and feedback control. Based on Fox-Li’s approach, including the self-focusing effect, the theoretical simulation reveals that the self-focusing effect is responsible for the self-adaptation. The self-adaptation occurs at the boundary between the chaotic and continuous output regions in which the laser system begins with a transient chaotic state with fractal correlation dimension, and then evolves with reducing dimension into the stable ML state.
NASA Technical Reports Server (NTRS)
Kharkovshy, S.; Zoughi, R.; Hepburn, F. L.
2007-01-01
Millimeter wave imaging techniques can provide high spatial-resolution images of various composites. Lens antennas may be incorporated into the imaging system to provide a small incident beam footprint. Another approach may involve the use of horn antennas, which if operating in their near-fields, images with reasonably high spatial-resolutions may also be obtained. This paper gives a comparison between such near-field and focused far-field imaging of the Space Shuttle Spray on Foam Insulation (SOFI) used in its external fuel tank at millimeter wave frequencies. Small horn antennas and lens antennas with relatively long depth of focus were used in this investigation.
Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.
Olsen, Thomas
2007-02-01
This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p < 0.00001). The number of predictions within +/- 0.5 D, +/- 1.0 D and +/- 2.0 D of the expected outcome was 62.5%, 92.4% and 99.9% with PCI, compared with 45.5%, 77.3% and 98.4% with ultrasound, respectively (p < 0.00001). The 2-variable ACD method resulted in an average error in PCI predictions of 0.46 D, which was significantly higher than the error in the 5-variable method (p < 0.001). The accuracy of IOL power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.
Lens-Aided Multi-Angle Spectroscopy (LAMAS) Reveals Small-Scale Outflow Structure in Quasars
NASA Astrophysics Data System (ADS)
Green, Paul J.
2006-06-01
Spectral differences between lensed quasar image components are common. Since lensing is intrinsically achromatic, these differences are typically explained as the effect of either microlensing, or as light path time delays sampling intrinsic quasar spectral variability. Here we advance a novel third hypothesis: some spectral differences are due to small line-of-sight differences through quasar disk wind outflows. In particular, we propose that variable spectral differences seen only in component A of the widest separation lens SDSS J1004+4112 are due to differential absorption along the sight lines. The absorber properties required by this hypothesis are akin to known broad absorption line (BAL) outflows but must have a broader, smoother velocity profile. We interpret the observed C IV emission-line variability as further evidence for spatial fine structure transverse to the line of sight. Since outflows are likely to be rotating, such absorber fine structure can consistently explain some of the UV and X-ray variability seen in AGNs. The implications are many: (1) Spectroscopic differences in other lensed objects may be due to this ``lens-aided multi-angle spectroscopy'' (LAMAS). (2) Outflows have fine structure on size scales of arcseconds, as seen from the nucleus. (3) Assuming either broad absorption line region sizes proposed in recent wind models, or typically assumed continuum emission region sizes, LAMAS and/or variability provide broadly consistent absorber size scale estimates of ~1015 cm. (4) Very broad smooth absorption may be ubiquitous in quasar spectra, even when no obvious troughs are seen.
Miniature electrically tunable rotary dual-focus lenses
NASA Astrophysics Data System (ADS)
Zou, Yongchao; Zhang, Wei; Lin, Tong; Chau, Fook Siong; Zhou, Guangya
2016-03-01
The emerging dual-focus lenses are drawing increasing attention recently due to their wide applications in both academia and industries, including laser cutting systems, microscopy systems, and interferometer-based surface profilers. In this paper, a miniature electrically tunable rotary dual-focus lens is developed. Such a lens consists of two optical elements, each having an optical flat surface and one freeform surface. The two freeform surfaces are initialized with the governing equation Ar2θ (A is the constant to be determined, r and θ denote the radii and angles in the polar coordinate system) and then optimized by ray tracing technique with additional Zernike polynomial terms for aberration correction. The freeform surfaces are achieved by a single-point diamond turning technique and then a PDMS-based replication process is utilized to materialize the final lens elements. To drive the two coaxial elements to rotate independently, two MEMS thermal rotary actuators are developed and fabricated by a standard MUMPs process. The experimental results show that the MEMS thermal actuator provides a maximum rotation angle of about 8.2 degrees with an input DC voltage of 6.5 V, leading to a wide tuning range for both the two focal lengths of the lens. Specifically, one focal length can be tuned from about 30 mm to 20 mm while the other one can be adjusted from about 30 mm to 60 mm.
Image registration reveals central lens thickness minimally increases during accommodation
Schachar, Ronald A; Mani, Majid; Schachar, Ira H
2017-01-01
Purpose To evaluate anterior chamber depth, central crystalline lens thickness and lens curvature during accommodation. Setting California Retina Associates, El Centro, CA, USA. Design Healthy volunteer, prospective, clinical research swept-source optical coherence biometric image registration study of accommodation. Methods Ten subjects (4 females and 6 males) with an average age of 22.5 years (range: 20–26 years) participated in the study. A 45° beam splitter attached to a Zeiss IOLMaster 700 (Carl Zeiss Meditec Inc., Jena, Germany) biometer enabled simultaneous imaging of the cornea, anterior chamber, entire central crystalline lens and fovea in the dilated right eyes of subjects before, and during focus on a target 11 cm from the cornea. Images with superimposable foveal images, obtained before and during accommodation, that met all of the predetermined alignment criteria were selected for comparison. This registration requirement assured that changes in anterior chamber depth and central lens thickness could be accurately and reliably measured. The lens radii of curvatures were measured with a pixel stick circle. Results Images from only 3 of 10 subjects met the predetermined criteria for registration. Mean anterior chamber depth decreased, −67 μm (range: −0.40 to −110 μm), and mean central lens thickness increased, 117 μm (range: 100–130 μm). The lens surfaces steepened, anterior greater than posterior, while the lens, itself, did not move or shift its position as appeared from the lack of movement of the lens nucleus, during 7.8 diopters of accommodation, (range: 6.6–9.7 diopters). Conclusion Image registration, with stable invariant references for image correspondence, reveals that during accommodation a large increase in lens surface curvatures is associated with only a small increase in central lens thickness and no change in lens position. PMID:28979092
Dynamic-focusing microscope objective for optical coherence tomography
NASA Astrophysics Data System (ADS)
Murali, Supraja; Rolland, Jannick
2007-01-01
Optical Coherence Tomography (OCT) is a novel optical imaging technique that has assumed significant importance in bio-medical imaging in the last two decades because it is non-invasive and provides accurate, high resolution images of three dimensional cross-sections of body tissue, exceeding the capabilities of the current predominant imaging technique - ultrasound. In this paper, the application of high resolution OCT, known as optical coherence microscopy (OCM) is investigated for in vivo detection of abnormal skin pathology for the early diagnosis of cancer. A main challenge in OCM is maintaining invariant resolution throughout the sample. The technology presented is based on a dynamic focusing microscope imaging probe conceived for skin imaging and the detection of abnormalities in the epithelium. A novel method for dynamic focusing in the biological sample is presented using variable-focus lens technology to obtain three dimensional images with invariant resolution throughout the cross-section and depth of the sample is presented and discussed. A low coherence broadband source centered at near IR wavelengths is used to illuminate the sample. The design, analysis and predicted performance of the dynamic focusing microscope objective designed for dynamic three dimensional imaging at 5μm resolution for the chosen broadband spectrum is presented.
Language Learning Motivation through a Small Lens: A Research Agenda
ERIC Educational Resources Information Center
Ushioda, Ema
2016-01-01
In this paper I propose an agenda for researching language learning motivation "through a small lens", to counteract our tendency in the second language (L2) motivation field to engage with language learning and teaching processes at a rather general level. I argue that by adopting a more sharply focused or contextualized angle of…
Why Creativity? Articulating and Championing a Museum's Social Mission
ERIC Educational Resources Information Center
Foley, Cindy Meyers
2014-01-01
In late 2006, the Columbus Museum of Art adopted a new framework that established creativity as the lens for learning and visitor experiences. When the Columbus Museum of Art committed to creativity as a focus and lens for learning, the work and nature of its education department adapted and changed. What is a museum's responsibility to its…
The Family Impact Lens: A Family-Focused, Evidence-Informed Approach to Policy and Practice
ERIC Educational Resources Information Center
Bogenschneider, Karen; Little, Olivia M.; Ooms, Theodora; Benning, Sara; Cadigan, Karen; Corbett, Thomas
2012-01-01
Families have long been recognized for the contributions they make to their members and to society. Yet families are seldom substantively incorporated into the normal course of policy and program development, implementation, and evaluation. We propose the family impact lens as one way to shift the rhetoric from appreciating families to…
Habits of Practice: Expanding Disciplinary Literacy Frameworks Through a Physical Education Lens
ERIC Educational Resources Information Center
Wickens, Corrine M.; Manderino, Michael; Parker, Jenny; Jung, Jinhong
2015-01-01
In recent years, disciplinary literacy has been at the forefront of adolescent literacy research and practice but has largely focused on the four core content areas: English language arts, social studies, science, and mathematics. Drawing on a physical education lens, this article is a call to expand the definitions, approaches, and framework of…
Ultra-thin metasurface microwave flat lens for broadband applications
Azad, Abul K.; Efimov, Anatoly V.; Ghosh, Shuprio; ...
2017-05-31
In this paper, we demonstrate a metasurface-based ultrathin flat lens operating at microwave frequencies. A series of subwavelength metallic split-ring resonators, which are sandwiched between two cross-polarized metallic gratings, are defined to obtain a radially symmetric parabolic phase distribution, covering relative phase differences ranging from 0 to 2.5π radians to create a lens. The tri-layer lens exhibits focusing/collimating of broadband microwaves from 7.0 to 10.0 GHz, with a gain enhancement of 17 dBi at a central wavelength 9.0 GHz while fed by a rectangular horn antenna. The measured focal length agrees reasonably well with design, achieving a 3 dB directionalitymore » <4.5° and confirming high-quality beam collimation along the propagation direction. Finally, the demonstrated metasurface flat lens enables light-weight, low-cost, and easily deployable flat transceivers for microwave communication, detection, and imaging applications.« less
Ultra-thin metasurface microwave flat lens for broadband applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azad, Abul K.; Efimov, Anatoly V.; Ghosh, Shuprio
In this paper, we demonstrate a metasurface-based ultrathin flat lens operating at microwave frequencies. A series of subwavelength metallic split-ring resonators, which are sandwiched between two cross-polarized metallic gratings, are defined to obtain a radially symmetric parabolic phase distribution, covering relative phase differences ranging from 0 to 2.5π radians to create a lens. The tri-layer lens exhibits focusing/collimating of broadband microwaves from 7.0 to 10.0 GHz, with a gain enhancement of 17 dBi at a central wavelength 9.0 GHz while fed by a rectangular horn antenna. The measured focal length agrees reasonably well with design, achieving a 3 dB directionalitymore » <4.5° and confirming high-quality beam collimation along the propagation direction. Finally, the demonstrated metasurface flat lens enables light-weight, low-cost, and easily deployable flat transceivers for microwave communication, detection, and imaging applications.« less
Ultra-thin metasurface microwave flat lens for broadband applications
Azad, Abul K.; Efimov, Anatoly V.; Ghosh, Shuprio; Singleton, John; Taylor, Antoinette J.
2017-01-01
We demonstrate a metasurface-based ultrathin flat lens operating at microwave frequencies. A series of subwavelength metallic split-ring resonators, which are sandwiched between two cross-polarized metallic gratings, are defined to obtain a radially symmetric parabolic phase distribution, covering relative phase differences ranging from 0 to 2.5π radians to create a lens. The tri-layer lens exhibits focusing/collimating of broadband microwaves from 7.0 to 10.0 GHz, with a gain enhancement of 17 dBi at a central wavelength 9.0 GHz while fed by a rectangular horn antenna. The measured focal length agrees reasonably well with design, achieving a 3 dB directionality <4.5° and confirming high-quality beam collimation along the propagation direction. The demonstrated metasurface flat lens enables light-weight, low-cost, and easily deployable flat transceivers for microwave communication, detection, and imaging applications. PMID:29104299
A Virtual Reality Simulator Prototype for Learning and Assessing Phaco-sculpting Skills
NASA Astrophysics Data System (ADS)
Choi, Kup-Sze
This paper presents a virtual reality based simulator prototype for learning phacoemulsification in cataract surgery, with focus on the skills required for making a cross-shape trench in cataractous lens by an ultrasound probe during the phaco-sculpting procedure. An immersive virtual environment is created with 3D models of the lens and surgical tools. Haptic device is also used as 3D user interface. Phaco-sculpting is simulated by interactively deleting the constituting tetrahedrons of the lens model. Collisions between the virtual probe and the lens are effectively identified by partitioning the space containing the lens hierarchically with an octree. The simulator can be programmed to collect real-time quantitative user data for reviewing and assessing trainee's performance in an objective manner. A game-based learning environment can be created on top of the simulator by incorporating gaming elements based on the quantifiable performance metrics.
Ultra-thin metasurface microwave flat lens for broadband applications.
Azad, Abul K; Efimov, Anatoly V; Ghosh, Shuprio; Singleton, John; Taylor, Antoinette J; Chen, Hou-Tong
2017-05-29
We demonstrate a metasurface-based ultrathin flat lens operating at microwave frequencies. A series of subwavelength metallic split-ring resonators, which are sandwiched between two cross-polarized metallic gratings, are defined to obtain a radially symmetric parabolic phase distribution, covering relative phase differences ranging from 0 to 2.5π radians to create a lens. The tri-layer lens exhibits focusing/collimating of broadband microwaves from 7.0 to 10.0 GHz, with a gain enhancement of 17 dBi at a central wavelength 9.0 GHz while fed by a rectangular horn antenna. The measured focal length agrees reasonably well with design, achieving a 3 dB directionality <4.5° and confirming high-quality beam collimation along the propagation direction. The demonstrated metasurface flat lens enables light-weight, low-cost, and easily deployable flat transceivers for microwave communication, detection, and imaging applications.
Cryogenic solid Schmidt camera as a base for future wide-field IR systems
NASA Astrophysics Data System (ADS)
Yudin, Alexey N.
2011-11-01
Work is focused on study of capability of solid Schmidt camera to serve as a wide-field infrared lens for aircraft system with whole sphere coverage, working in 8-14 um spectral range, coupled with spherical focal array of megapixel class. Designs of 16 mm f/0.2 lens with 60 and 90 degrees sensor diagonal are presented, their image quality is compared with conventional solid design. Achromatic design with significantly improved performance, containing enclosed soft correcting lens behind protective front lens is proposed. One of the main goals of the work is to estimate benefits from curved detector arrays in 8-14 um spectral range wide-field systems. Coupling of photodetector with solid Schmidt camera by means of frustrated total internal reflection is considered, with corresponding tolerance analysis. The whole lens, except front element, is considered to be cryogenic, with solid Schmidt unit to be flown by hydrogen for improvement of bulk transmission.
Nanofocusing with aberration-corrected rotationally parabolic refractive X-ray lenses
Seiboth, Frank; Wittwer, Felix; Scholz, Maria; ...
2018-01-01
Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with σ¯ = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without priormore » lens characterization but simply based on the derived lens deformation. As a result, the performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.« less
Variable path length spectrophotometric probe
O'Rourke, Patrick E.; McCarty, Jerry E.; Haggard, Ricky A.
1992-01-01
A compact, variable pathlength, fiber optic probe for spectrophotometric measurements of fluids in situ. The probe comprises a probe body with a shaft having a polished end penetrating one side of the probe, a pair of optic fibers, parallel and coterminous, entering the probe opposite the reflecting shaft, and a collimating lens to direct light from one of the fibers to the reflecting surface of the shaft and to direct the reflected light to the second optic fiber. The probe body has an inlet and an outlet port to allow the liquid to enter the probe body and pass between the lens and the reflecting surface of the shaft. A linear stepper motor is connected to the shaft to cause the shaft to advance toward or away from the lens in increments so that absorption measurements can be made at each of the incremental steps. The shaft is sealed to the probe body by a bellows seal to allow freedom of movement of the shaft and yet avoid leakage from the interior of the probe.
Focused Heavy Ion Nuclear Microprobe facility at the University of North Texas
NASA Astrophysics Data System (ADS)
Guo, B. N.; Yang, C.; El Bouanani, M.; Duggan, J. L.; McDaniel, F. D.
1999-10-01
A Focused Heavy Ion Nuclear Microprobe facility has been constructed at the University of North Texas. The microprobe utilizes two separated Russian magnetic quadrupole quadruplets. The two identical magnetic quadrupole doublet lenses are separated by 2.61 meters. The lens system with ~ 80 times demagnification has the ability to focus proton, alpha particle, or heavier ions down to a spot size of ~ 1 μm. The microprobe components rest on a 7 meter steel beam support with vibration isolation. A computer provides control for the lens power supplies and also the parameters for a post-lens scanning coil to raster-scan the beam across the sample. Up to four detection channels can be used for simultaneous data acquisition under VME control. A RISC workstation is used to collect, display and analyze the data. The data is transferred via ethernet. A detailed description of the facility and data acquisition system along with preliminary testing results on TEM grids with Rutherford Backscattering Spectrometry and the Ion Beam Induced Charge Collection techniques will be presented.
Single lens 3D-camera with extended depth-of-field
NASA Astrophysics Data System (ADS)
Perwaß, Christian; Wietzke, Lennart
2012-03-01
Placing a micro lens array in front of an image sensor transforms a normal camera into a single lens 3D camera, which also allows the user to change the focus and the point of view after a picture has been taken. While the concept of such plenoptic cameras is known since 1908, only recently the increased computing power of low-cost hardware and the advances in micro lens array production, have made the application of plenoptic cameras feasible. This text presents a detailed analysis of plenoptic cameras as well as introducing a new type of plenoptic camera with an extended depth of field and a maximal effective resolution of up to a quarter of the sensor resolution.
NASA Astrophysics Data System (ADS)
Marocchino, A.; Anania, M. P.; Bellaveglia, M.; Biagioni, A.; Bini, S.; Bisesto, F.; Brentegani, E.; Chiadroni, E.; Cianchi, A.; Croia, M.; Di Giovenale, D.; Ferrario, M.; Filippi, F.; Giribono, A.; Lollo, V.; Marongiu, M.; Mostacci, A.; Di Pirro, G.; Pompili, R.; Romeo, S.; Rossi, A. R.; Scifo, J.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Zigler, A.
2017-10-01
We report on the experimental characterization of the effect that a passive plasma lens in the overdense regime has on high-brightness bunch quality by means of 6D phase-space analysis. The passive lens is generated by confining hydrogen gas with a capillary tube pre-ionized with a high-voltage discharge. We observed that the optimum condition is retrieved at the end of the overdense regime with almost no effect on bunch brightness. The presence of gas jets, leaking from the hollow capillary end-points, extends the lens effects also outside of the capillary, resulting in longer focusing channels. Experimental results are supported with numerical simulations of the complete accelerator line together with the plasma channel section.
Electrophoretic variation in low molecular weight lens crystallins from inbred strains of rats.
Donner, M E; Skow, L C; Kunz, H W; Gill, T J
1985-10-01
Analysis of rat lens soluble proteins by analytical isoelectric focusing detected two inherited electrophoretic differences in low molecular weight (LM) crystallins from inbred strains of rats (Rattus norvegicus). The polymorphic lens crystallins were shown to be similar to a genetically variant LM crystallin, LEN-1, previously described in mice (Mus musculus) and encoded on chromosome 1, at a locus linked to Pep-3 (dipeptidase). Linkage analysis demonstrated that the rat crystallin locus was loosely linked to Pep-3 at a recombination distance of 38 +/- 4.5 U. These data suggest the conservation of a large chromosomal region during the evolution of Rodentia and support the hypothesis that the gamma-crystallins are evolving more rapidly than alpha- or beta-crystallins.
An analytical and experimental evaluation of a Fresnel lens solar concentrator
NASA Technical Reports Server (NTRS)
Hastings, L. J.; Allums, S. A.; Cosby, R. M.
1976-01-01
An analytical and experimental evaluation of line focusing Fresnel lenses with application potential in the 200 to 370 C range was studied. Analytical techniques were formulated to assess the solar transmission and imaging properties of a grooves down lens. Experimentation was based on a 56 cm wide, f/1.0 lens. A Sun tracking heliostat provided a nonmoving solar source. Measured data indicated more spreading at the profile base than analytically predicted, resulting in a peak concentration 18 percent lower than the computed peak of 57. The measured and computed transmittances were 85 and 87 percent, respectively. Preliminary testing with a subsequent lens indicated that modified manufacturing techniques corrected the profile spreading problem and should enable improved analytical experimental correlation.
An analytical and experimental evaluation of the plano-cylindrical Fresnel lens solar concentrator
NASA Technical Reports Server (NTRS)
Hastings, L. J.; Allums, S. L.; Cosby, R. M.
1976-01-01
Plastic Fresnel lenses for solar concentration are attractive because of potential for low-cost mass production. An analytical and experimental evaluation of line-focusing Fresnel lenses with application potential in the 200 to 370 C range is reported. Analytical techniques were formulated to assess the solar transmission and imaging properties of a grooves-down lens. Experimentation was based primarily on a 56 cm-wide lens with f-number 1.0. A sun-tracking heliostat provided a non-moving solar source. Measured data indicated more spreading at the profile base than analytically predicted. The measured and computed transmittances were 85 and 87% respectively. Preliminary testing with a second lens (1.85 m) indicated that modified manufacturing techniques corrected the profile spreading problem.
Extralenticular and lenticular aspects of accommodation and presbyopia in human versus monkey eyes.
Croft, Mary Ann; McDonald, Jared P; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L
2013-07-26
To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components-muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above-are most important in predicting accommodative amplitude and presbyopia. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19-65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6-27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function.
NASA Astrophysics Data System (ADS)
Santiago-Alvarado, A.; Cruz-Félix, A.; Hernández Méndez, A.; Pérez-Maldonado, Y.; Domínguez-Osante, C.
2015-05-01
Tunable lenses have attracted much attention due to their potential applications in such areas like machine vision, laser projection, ophthalmology, etc. In this work we present the design of a tunable opto-mechatronic system capable of focusing and to regulate the entrance illumination that mimics the performance made by the iris and the crystalline lens of the human eye. A solid elastic lens made of PDMS has been used in order to mimic the crystalline lens and an automatic diaphragm has been used to mimic the iris of the human eye. Also, a characterization of such system has been performed with standard values of luminosity for the human eye have been taken into account to calibrate and to validate the entrance illumination levels to the overall optical system.
Microwave Nondestructive Evaluation of Dielectric Materials with a Metamaterial Lens
NASA Technical Reports Server (NTRS)
Shreiber, Daniel; Gupta, Mool; Cravey, Robin L.
2008-01-01
A novel microwave Nondestructive Evaluation (NDE) sensor was developed in an attempt to increase the sensitivity of the microwave NDE method for detection of defects small relative to a wavelength. The sensor was designed on the basis of a negative index material (NIM) lens. Characterization of the lens was performed to determine its resonant frequency, index of refraction, focus spot size, and optimal focusing length (for proper sample location). A sub-wavelength spot size (3 dB) of 0.48 lambda was obtained. The proof of concept for the sensor was achieved when a fiberglass sample with a 3 mm diameter through hole (perpendicular to the propagation direction of the wave) was tested. The hole was successfully detected with an 8.2 cm wavelength electromagnetic wave. This method is able to detect a defect that is 0.037 lambda. This method has certain advantages over other far field and near field microwave NDE methods currently in use.
Stretched Lens Array Photovoltaic Concentrator Technology Developed
NASA Technical Reports Server (NTRS)
Piszczor, Michael F., Jr.; O'Neill, Mark J.
2004-01-01
Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.
Xie, Peng; Lin, Huichuan; Liu, Yong; Li, Baojun
2014-10-20
We present a waveguide coupling approach for planar waveguide solar concentrator. In this approach, total internal reflection (TIR)-based symmetric air prisms are used as couplers to increase the coupler reflectivity and to maximize the optical efficiency. The proposed concentrator consists of a line focusing cylindrical lens array over a planar waveguide. The TIR-based couplers are located at the focal line of each lens to couple the focused sunlight into the waveguide. The optical system was modeled and simulated with a commercial ray tracing software (Zemax). Results show that the system used with optimized TIR-based couplers can achieve 70% optical efficiency at 50 × geometrical concentration ratio, resulting in a flux concentration ratio of 35 without additional secondary concentrator. An acceptance angle of ± 7.5° is achieved in the x-z plane due to the use of cylindrical lens array as the primary concentrator.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saifee, T.; Konnerth, A. III
1991-11-01
Solar Kinetics, Inc. (SKI) has been developing point-focus concentrating PV modules since 1986. SKI is currently in position to manufacture between 200 to 600 kilowatts annually of the current design by a combination of manual and semi-automated methods. This report reviews the current status of module manufacture and specifies the required approach to achieve a high-volume manufacturing capability and low cost. The approach taken will include process development concurrent with module design for automated manufacturing. The current effort reviews the major manufacturing costs and identifies components and processes whose improvements would produce the greatest effect on manufacturability and cost reduction.more » The Fresnel lens is one such key component. Investigating specific alternative manufacturing methods and sources has substantially reduced the lens costs and has exceeded the DOE cost-reduction goals. 15 refs.« less
Hyperbolic metamaterial lens with hydrodynamic nonlocal response.
Yan, Wei; Mortensen, N Asger; Wubs, Martijn
2013-06-17
We investigate the effects of hydrodynamic nonlocal response in hyperbolic metamaterials (HMMs), focusing on the experimentally realizable parameter regime where unit cells are much smaller than an optical wavelength but much larger than the wavelengths of the longitudinal pressure waves of the free-electron plasma in the metal constituents. We derive the nonlocal corrections to the effective material parameters analytically, and illustrate the noticeable nonlocal effects on the dispersion curves numerically. As an application, we find that the focusing characteristics of a HMM lens in the local-response approximation and in the hydrodynamic Drude model can differ considerably. In particular, the optimal frequency for imaging in the nonlocal theory is blueshifted with respect to that in the local theory. Thus, to detect whether nonlocal response is at work in a hyperbolic metamaterial, we propose to measure the near-field distribution of a hyperbolic metamaterial lens.
Marx, Sebastian; Sickenberger, Wolfgang
2017-12-01
This study was designed to develop a novel technique called non-invasive keratograph dry-up time (NIK-DUT), which used an adapted corneal topographer, to analyse in-vitro contact lens surface dewetting and the effects of combinations of lenses and lens care solutions on dewetting. Variables were assessed to optimise sensitivity and reproducibility. To validate the method, in-vitro dewetting of silicone hydrogel contact lenses (balafilcon A, comfilcon A, lotrafilcon A, lotrafilcon B and senofilcon A) was tested. All lens types were soaked in OPTI-FREE ® PureMoist ® Multipurpose Disinfecting Solution (OFPM) and Sensitive Eyes ® Saline Solution. The mean NIK-DUT, defined as drying of 25% of the placido ring measurement segments (NIK-DUT_S25), was calculated for each lens/lens solution combination and a visual map constructed representing the time and location of the dry-up event. Optimal conditions for NIK-DUT measurement included mounting onto a glass stage with a surface geometry of r=8.5mm, e=0, and measuring with high intensity red or white illumination. This method detected significant differences in contact lens dewetting with different lens soaking solutions. NIK-DUT_S25 for all lenses was longer when pre-soaked in OFPM versus saline. Visual analysis showed that dewetting of contact lenses was not uniform across surfaces and differed between test solutions. NIK-DUT is suitable for detecting differences in dewetting among various contact lenses and lens-care combinations. NIK-DUT can quantify the dewetting of large areas of lens surfaces with little subjective influence. Lens care solutions containing surface-active wetting agents were found to delay surface dewetting of silicone hydrogel lenses. Copyright © 2017. Published by Elsevier Ltd.
Shoji, Takuhei; Kato, Naoko; Ishikawa, Sho; Ibuki, Hisashi; Yamada, Norihiro; Kimura, Itaru; Shinoda, Kei
2017-01-01
To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), -1 D, -3 D and -5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. The intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects. This novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress.
Shoji, Takuhei; Kato, Naoko; Ishikawa, Sho; Ibuki, Hisashi; Yamada, Norihiro; Kimura, Itaru; Shinoda, Kei
2017-01-01
Objective To evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. Methods and analysis One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), −1 D, −3 D and −5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. Results The intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects. Conclusions This novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress. PMID:29354706
Feng, Guo-Hua; Liu, Jun-Hao
2013-02-01
This paper proposes a tunable-focus liquid lens implemented with a simple cylindrical container structure and liquid as the lens material. The cylindrical container was constructed using a Pb [Zr(0.52)Ti(0.48)]O(3) (PZT) ring transducer and a polydimethylsiloxane membrane that was attached to a flat side of the transducer. The free surface of the liquid in the cylindrical container can be driven as a static-like convex lens with different curvatures because the higher-order harmonic resonance of the PZT transducer was electrically controlled. Based on a capillary-force-dominant design, the activated liquid lens maintained surface curvature in an arbitrary orientation without a gravitational effect. Profiles of the liquid lenses were characterized with the driving voltages of the transducer ranging from 12 to 60 V peak-to-peak (Vpp) at a resonant frequency of 460 kHz. The temperature effects on the lenses caused by the continuous operation of the transducer were measured. Images showed the various curvatures of the lenses with a range of actuation voltages. A change in focal length of eight times (5.72 to 46.03 cm) was demonstrated within the 10 Vpp variation of the driving voltage. For the characterized liquid lenses, the distortion was less than 2%, and the modulation transfer function reached 63 line pairs per mm (lp/mm) using ZEMAX analysis.
NASA Astrophysics Data System (ADS)
Selker, Ted
1983-05-01
Lens focusing using a hardware model of a retina (Reticon RL256 light sensitive array) with a low cost processor (8085 with 512 bytes of ROM and 512 bytes of RAM) was built. This system was developed and tested on a variety of visual stimuli to demonstrate that: a)an algorithm which moves a lens to maximize the sum of the difference of light level on adjacent light sensors will converge to best focus in all but contrived situations. This is a simpler algorithm than any previously suggested; b) it is feasible to use unmodified video sensor arrays with in-expensive processors to aid video camera use. In the future, software could be developed to extend the processor's usefulness, possibly to track an actor by panning and zooming to give a earners operator increased ease of framing; c) lateral inhibition is an adequate basis for determining best focus. This supports a simple anatomically motivated model of how our brain focuses our eyes.
Focusing effect of bent GaAs crystals for γ-ray Laue lenses: Monte Carlo and experimental results
NASA Astrophysics Data System (ADS)
Virgilli, E.; Frontera, F.; Rosati, P.; Bonnini, E.; Buffagni, E.; Ferrari, C.; Stephen, J. B.; Caroli, E.; Auricchio, N.; Basili, A.; Silvestri, S.
2016-02-01
We report on results of observation of the focusing effect from the planes (220) of Gallium Arsenide (GaAs) crystals. We have compared the experimental results with the Monte Carlo simulations of the focusing capability of GaAs tiles performed with a dedicated ray-tracer. The GaAs tiles were bent using a lapping process developed at the cnr/imem - Parma (Italy) in the framework of the laue project, funded by ASI, dedicated to build a broad band Laue lens prototype for astrophysical applications in the hard X-/soft γ-ray energy range (80-600 keV). We present and discuss the results obtained from their characterization, mainly in terms of focusing capability. Bent crystals will significantly increase the signal to noise ratio of a telescope based on a Laue lens, consequently leading to an unprecedented enhancement of sensitivity with respect to the present non focusing instrumentation.
Crystalline lens thickness determines the perceived chromatic difference in magnification.
Chen, Yun; Schaeffel, Frank
2014-03-01
Since the origin of the high interindividual variability of the chromatic difference in retinal image magnification (CDM) in the human eye is not well understood, optical parameters that might determine its magnitude were studied in 21 healthy subjects with ages ranging from 21 to 58 years. Two psychophysical procedures were used to quantify CDM. They produced highly correlated results. First, a red and a blue square, presented on a black screen, had to be matched in size by the subjects with their right eyes. Second, a filled red and blue square, flickering on top of each other at 2 Hz, had to be adjusted in perceived brightness and then in size to minimize the impression of flicker. CDM varied widely among subjects from 0.0% to 3.6%. Biometric ocular parameters were measured with low coherence interferometry and crystalline lens tilt and decentration with a custom-built Purkinjemeter. Correlations were studied between CDM and corneal power, anterior chamber depth, lens thickness, lens tilt and lens decentration, and vitreous chamber depths. Lens thickness was found significantly correlated with CDM and accounted for 64% of its variance. Vertical lens tilt and decentration were also significantly correlated. It was also found that CDM increased by 3.5% per year, and part of this change can be attributed to the age-related increase in lens thickness.
Photovoltaic applications of Compound Parabolic Concentrator (CPC)
NASA Technical Reports Server (NTRS)
Winston, R.
1975-01-01
The use of a compound parabolic concentrator as field collector, in conjunction with a primary focusing concentrator for photovoltaic applications is studied. The primary focusing concentrator can be a parabolic reflector, an array of Fresnel mirrors, a Fresnel lens or some other lens. Silicon solar cell grid structures are proposed that increase efficiency with concentration up to 10 suns. A ray tracing program has been developed to determine energy distribution at the exit of a compound parabolic concentrator. Projected total cost of a CPC/solar cell system will be between 4 and 5 times lower than for flat plate silicon cell arrays.
Linearization of an annular image by using a diffractive optic
NASA Technical Reports Server (NTRS)
Matthys, Donald R.
1996-01-01
The goal for this project is to develop the algorithms for fracturing the zones defined by the mapping transformation, and to actually produce the binary optic in an appropriate setup. In 1984 a side-viewing panoramic viewing system was patented, consisting of a single piece of glass with spherical surfaces which produces a 360 degree view of the region surrounding the lens which extends about 25 degrees in front of and 20 degrees behind the lens. The system not only produces images of good quality, it is also afocal, i.e., images stay in focus for objects located right next to the lens as well as those located far from the lens. The lens produced a panoramic view in an annular shaped image, and so the lens was called a PAL (panoramic annular lens). When applying traditional measurements to PAL images, it is found advantageous to linearize the annular image. This can easily be done with a computer and such a linearized image can be produced within about 40 seconds on current microcomputers. However, this process requires a frame-grabber and a computer, and is not real-time. Therefore, it was decided to try to perform this linearization optically by using a diffractive optic.
Numerical Modeling of the Deformation Behavior of Fault Bounded Lens Shaped Bodies in 2D
NASA Astrophysics Data System (ADS)
van der Zee, W.; Urai, J. L.
2001-12-01
Fault zones cause dramatic discontinuous changes in mechanical properties. The early stages of evolution of fault zones are important for its long-term behavior. We consider faults which develop from deformation bands or pre-existing joints which are the initially unconnected discontinuities. With further deformation, these coalesce into a connected network, and develop into a 'mature' fault gouge. When segments are not coplanar, soft linkage or bends in the fault plane (releasing and restraining bends, fault bounded lens-shaped bodies etc) necessarily occurs. Further movement causes additional deformation, and the fault zone has a strongly variable thickness. Here, we present the results of detailed fieldwork combined with numerical modeling on the deformation of fault bounded lens-shaped bodies in the fault zone. Detailed study of a number of lenses in the field shows that the lens is invariably more deformed than the surrounding material. This observation can be explained in several ways. In one end member most of the deformation in the future lens occurs before full coalescence of the slip planes and the formation of the lens. The other end member is that the slip planes coalesce before plastic deformation of the lens is occurring. The internal deformation of the lens occurs after the lens is formed, due to the redistributed stresses in the structure. If this is the case, then lens shaped bodies can be always expected to deform preferentially. Finite element models were used to investigate the shear behavior of a planar fault with a lens shaped body or a sinus-shaped asperity. In a sensitivity analysis, we consider different lens shapes and fault friction coefficients. Results show that 1) during slip, the asperity shears off to form a lens shaped body 2) lens interior deforms more than the surroundings, due to the redistribution of stresses 3) important parameters in this system are the length-thickness ratio of the lens and the fault friction coefficient 4) lens structures can evolve in different ways, but in the final stage the result is a lens with deformed interior In the later stages after further displacement, these zones of preferential deformation evolve into sections containing thick gouge, and the initial lens width controls long term fault gouge thickness.
Assessment of a liquid lens enabled in vivo optical coherence microscope.
Murali, Supraja; Meemon, Panomsak; Lee, Kye-Sung; Kuhn, William P; Thompson, Kevin P; Rolland, Jannick P
2010-06-01
The optical aberrations induced by imaging through skin can be predicted using formulas for Seidel aberrations of a plane-parallel plate. Knowledge of these aberrations helps to guide the choice of numerical aperture (NA) of the optics we can use in an implementation of Gabor domain optical coherence microscopy (GD-OCM), where the focus is the only aberration adjustment made through depth. On this basis, a custom-designed, liquid-lens enabled dynamic focusing optical coherence microscope operating at 0.2 NA is analyzed and validated experimentally. As part of the analysis, we show that the full width at half-maximum metric, as a characteristic descriptor for the point spread function, while commonly used, is not a useful metric for quantifying resolution in non-diffraction-limited systems. Modulation transfer function (MTF) measurements quantify that the liquid lens performance is as predicted by design, even when accounting for the effect of gravity. MTF measurements in a skinlike scattering medium also quantify the performance of the microscope in its potential applications. To guide the fusion of images across the various focus positions of the microscope, as required in GD-OCM, we present depth of focus measurements that can be used to determine the effective number of focusing zones required for a given goal resolution. Subcellular resolution in an onion sample, and high-definition in vivo imaging in human skin are demonstrated with the custom-designed and built microscope.
Visible light focusing flat lenses based on hybrid dielectric-metal metasurface reflector-arrays
Fan, Qingbin; Huo, Pengcheng; Wang, Daopeng; Liang, Yuzhang; Yan, Feng; Xu, Ting
2017-01-01
Conventional metasurface reflector-arrays based on metallic resonant nanoantenna to control the wavefront of light for focusing always suffer from strong ohmic loss at optical frequencies. Here, we overcome this challenge by constructing a non-resonant, hybrid dielectric-metal configuration consisting of TiO2 nanofins associated with an Ag reflector substrate that provides a broadband response and high polarization conversion efficiency in the visible range. A reflective flat lens based on this configuration shows an excellent focusing performance with the spot size close to the diffraction limit. Furthermore, by employing the superimposed phase distribution design to manipulate the wavefront of the reflected light, various functionalities, such as multifocal and achromatic focusing, are demonstrated for the flat lenses. Such a reflective flat lens will find various applications in visible light imaging and sensing systems. PMID:28332611
Optical Manipulation along Optical Axis with Polarization Sensitive Meta-lens.
Markovich, Hen; Shishkin, Ivan; Hendler, Netta; Ginzburg, Pavel
2018-06-27
The ability to manipulate small objects with focused laser beams opens a broad spectrum of opportunities in fundamental and applied studies, where a precise control over mechanical path and stability is required. While conventional optical tweezers are based on bulky diffractive optical elements, developing compact integrable within a fluid cell trapping devices is highly demanded. Here, plasmonic polarization sensitive metasurface-based lens, embedded within a fluid, is demonstrated to provide several stable trapping centers along the optical axis. The position of a particle is controlled with the polarization of the incident light, interacting with plasmonic nanoscale patch antennas, organized within overlapping Fresnel zones of the lens. While standard diffractive optical elements face challenges to trap objects in lateral direction outside the depth of focus, bi-focal Fresnel meta-lens demonstrates the capability to manipulate a bead along 4 micrometers line. Additional fluorescent module, incorporated within the optical trapping setup, was implemented and enabled accurate mapping of optical potential via a particle tracking algorithm. Auxiliary micro- and nano- structures, integrated within fluidic devices, provide numerous opportunities to achieve flexible optomechanical manipulation, including, transport, trapping and sorting, which are highly demanded in lab-on-a-chip applications and many others.
Quasi-mosaicity of (311) planes in silicon and its use in a Laue lens with high-focusing power
NASA Astrophysics Data System (ADS)
Camattari, Riccardo; Paternò, Gianfranco; Bellucci, Valerio; Guidi, Vincenzo
2014-12-01
(311) curved planes can be exploited for efficiently focus hard X-rays. With this purpose, a self-standing bent crystal was manufactured at the Sensor and Semiconductor Laboratory of Ferrara (Italy). The crystal was designed as an optical component for a X-ray concentrator such as a Laue lens. The curvature of (311) planes was obtained through the quasi-mosaic effect. The diffraction efficiency of the sample was tested at the Institut Laue Langevin of Grenoble (France) by using a collimated monochromatic X-ray beam. This was the first prove of the diffraction properties of (311) quasi-mosaic planes. Diffraction efficiency resulted 35 % with a 182 keV X-ray beam, in agreement with the theoretical expectation. It corresponded to a reflectivity of 33 %. While the chosen orientation is not the most performing lying of planes, it can be used, in addition to smaller-index planes, in order to raise the total effective area of a Laue lens. To quantify it, a Laue lens based on quasi-mosaic silicon and germanium crystals, exploiting (111), (422) and (311) diffracting planes, was achieved and simulated with the LaueGen code.
Highly efficient multifunctional metasurface for high-gain lens antenna application
NASA Astrophysics Data System (ADS)
Hou, Haisheng; Wang, Guangming; Li, Haipeng; Guo, Wenlong; Li, Tangjing
2017-07-01
In this paper, a novel multifunctional metasurface combining linear-to-circular polarization conversion and electromagnetic waves focusing has been proposed and applied to design a high-gain lens antenna working at Ku band. The multifunctional metasurface consists of 15 × 15 unit cells. Each unit cell is composed of four identical metallic layers and three intermediate dielectric layers. Due to well optimization, the multifunctional metasurface can convert the linearly polarized waves generated by the source to circularly polarized waves and focus the waves. By placing a patch antenna operating at 15 GHz at the focal point of the metasurface and setting the focal distance to diameter ratio ( F/ D) to 0.34, we obtain a multifunctional lens antenna. Simulated and measured results coincide well, indicating that the metasurface can convert linearly polarized waves to right-handed circularly polarized waves at 15 GHz with excellent performances in terms of the 3 dB axial ratio bandwidth of 5.3%, realized gain of 16.9 dB and aperture efficiency of 41.2%. Because of the advantages of high gain, competitive efficiency and easy fabrication, the proposed lens antenna has a great potential application in wireless and satellite communication.
Three-dimensional microscope tracking system using the astigmatic lens method and a profile sensor
NASA Astrophysics Data System (ADS)
Kibata, Hiroki; Ishii, Katsuhiro
2018-03-01
We developed a three-dimensional microscope tracking system using the astigmatic lens method and a profile sensor, which provides three-dimensional position detection over a wide range at the rate of 3.2 kHz. First, we confirmed the range of target detection of the developed system, where the range of target detection was shown to be ± 90 µm in the horizontal plane and ± 9 µm in the vertical plane for a 10× objective lens. Next, we attempted to track a motion-controlled target. The developed system kept the target at the center of the field of view and in focus up to a target speed of 50 µm/s for a 20× objective lens. Finally, we tracked a freely moving target. We successfully demonstrated the tracking of a 10-µm-diameter polystyrene bead suspended in water for 40 min. The target was kept in the range of approximately 4.9 µm around the center of the field of view. In addition, the vertical direction was maintained in the range of ± 0.84 µm, which was sufficiently within the depth of focus.
One dimensional wavefront distortion sensor comprising a lens array system
Neal, Daniel R.; Michie, Robert B.
1996-01-01
A 1-dimensional sensor for measuring wavefront distortion of a light beam as a function of time and spatial position includes a lens system which incorporates a linear array of lenses, and a detector system which incorporates a linear array of light detectors positioned from the lens system so that light passing through any of the lenses is focused on at least one of the light detectors. The 1-dimensional sensor determines the slope of the wavefront by location of the detectors illuminated by the light. The 1 dimensional sensor has much greater bandwidth that 2 dimensional systems.
Imaging objects behind small obstacles using axicon lens
NASA Astrophysics Data System (ADS)
Perinchery, Sandeep M.; Shinde, Anant; Murukeshan, V. M.
2017-06-01
Axicon lenses are conical prisms, which are known to focus a light source to a line comprising of multiple points along the optical axis. In this study, we analyze the potential of axicon lenses to view, image and record the object behind opaque obstacles in free space. The advantage of an axicon lens over a regular lens is demonstrated experimentally. Parameters such as obstacle size, object and the obstacle position in the context of imaging behind obstacles are tested using Zemax optical simulation. This proposed concept can be easily adapted to most of the optical imaging methods and microscopy modalities.
One dimensional wavefront distortion sensor comprising a lens array system
Neal, D.R.; Michie, R.B.
1996-02-20
A 1-dimensional sensor for measuring wavefront distortion of a light beam as a function of time and spatial position includes a lens system which incorporates a linear array of lenses, and a detector system which incorporates a linear array of light detectors positioned from the lens system so that light passing through any of the lenses is focused on at least one of the light detectors. The 1-dimensional sensor determines the slope of the wavefront by location of the detectors illuminated by the light. The 1 dimensional sensor has much greater bandwidth that 2 dimensional systems. 8 figs.
Coherent diffraction imaging by moving a lens.
Shen, Cheng; Tan, Jiubin; Wei, Ce; Liu, Zhengjun
2016-07-25
A moveable lens is used for determining amplitude and phase on the object plane. The extended fractional Fourier transform is introduced to address the single lens imaging. We put forward a fast algorithm for the transform by convolution. Combined with parallel iterative phase retrieval algorithm, it is applied to reconstruct the complex amplitude of the object. Compared with inline holography, the implementation of our method is simple and easy. Without the oversampling operation, the computational load is less. Also the proposed method has a superiority of accuracy over the direct focusing measurement for the imaging of small size objects.
Dual-beam laser autofocusing system based on liquid lens
NASA Astrophysics Data System (ADS)
Zhang, Fumin; Yao, Yannan; Qu, Xinghua; Zhang, Tong; Pei, Bing
2017-02-01
A dual-beam laser autofocusing system is designed in this paper. The autofocusing system is based on a liquid lens with less moving parts and fast response time, which makes the system simple, reliable, compact and fast. A novel scheme ;Time-sharing focus, fast conversion; is innovatively proposed. The scheme effectively solves the problem that the guiding laser and the working laser cannot focus at the same target point because of the existence of chromatic aberration. This scheme not only makes both guiding laser and working laser achieve optimal focusing in guiding stage and working stage respectively, but also greatly reduces the system complexity and simplifies the focusing process as well as makes autofocusing time of the working laser reduce to about 10 ms. In the distance range of 1 m to 30 m, the autofocusing spot size is kept under 4.3 mm at 30 m and just 0.18 mm at 1 m. The spot size is much less influenced by the target distance compared with the collimated laser with a micro divergence angle for its self-adaptivity. The dual-beam laser autofocusing system based on liquid lens is fully automatic, compact and efficient. It is fully meet the need of dynamicity and adaptivity and it will play an important role in a number of long-range control applications.
NASA Astrophysics Data System (ADS)
Apostolos, John; Mouyos, William; Feng, Judy; Chase, Walter
2015-05-01
The need for advanced techniques to detect improvised explosive devices (IED) at stand-off distances greater than ten (10) meters has driven AMI Research and Development (AMI) to develop a solution to detect and identify the threat utilizing a forward looking Synthetic Aperture Radar (SAR) combined with our CW radar technology Nuclear Quadrupole Resonance (NQR) detection system. The novel features include a near-field sub-wavelength focusing antenna, a wide band 300 KHz to 300 MHz rapidly scanning CW radar facilitated by a high Q antenna/tuner, and an advanced processor utilizing Rabi transitions where the nucleus oscillates between states under the time dependent incident electromagnetic field and alternately absorbs energy from the incident field while emitting coherent energy via stimulated emission. AMI's Sub-wavelength Focusing Wide Band Super Lens uses a Near-Field SAR, making detection possible at distances greater than ten (10) meters. This super lens is capable of operating on the near-field and focusing electromagnetic waves to resolutions beyond the diffraction limit. When applied to the case of a vehicle approaching an explosive hazard the methodologies of synthetic aperture radar is fused with the array based super resolution and the NQR data processing detecting the explosive hazard.
NASA Astrophysics Data System (ADS)
Lacki, Brian C.; Kochanek, Christopher S.; Stanek, Krzysztof Z.; Inada, Naohisa; Oguri, Masamune
2009-06-01
Difference imaging provides a new way to discover gravitationally lensed quasars because few nonlensed sources will show spatially extended, time variable flux. We test the method on the fields of lens candidates in the Sloan Digital Sky Survey (SDSS) Supernova Survey region from the SDSS Quasar Lens Search (SQLS) and one serendipitously discovered lensed quasar. Starting from 20,536 sources, including 49 SDSS quasars, 32 candidate lenses/lensed images, and one known lensed quasar, we find that 174 sources including 35 SDSS quasars, 16 candidate lenses/lensed images, and the known lensed quasar are nonperiodic variable sources. We can measure the spatial structure of the variable flux for 119 of these variable sources and identify only eight as candidate extended variables, including the known lensed quasar. Only the known lensed quasar appears as a close pair of sources on the difference images. Inspection of the remaining seven suggests they are false positives, and only two were spectroscopically identified quasars. One of the lens candidates from the SQLS survives our cuts, but only as a single image instead of a pair. This indicates a false positive rate of order ~1/4000 for the method, or given our effective survey area of order 0.82 deg2, ~5 per deg2 in the SDSS Supernova Survey. The fraction of quasars not found to be variable and the false positive rate would both fall if we had analyzed the full, later data releases for the SDSS fields. While application of the method to the SDSS is limited by the resolution, depth, and sampling of the survey, several future surveys such as Pan-STARRS, LSST, and SNAP will significantly improve on these limitations.
Kao, Yung-Yuan; Chao, Paul C.-P.
2011-01-01
A new liquid crystal lens design is proposed to improve the recovery time with a ring-and-pie electrode pattern through a suitable driving scheme and using dual-frequency liquid crystals (DFLC) MLC-2048. Compared with the conventional single hole-type liquid crystal lens, this new structure of the DFLC lens is composed of only two ITO glasses, one of which is designed with the ring-and-pie pattern. For this device, one can control the orientation of liquid crystal directors via a three-stage switching procedure on the particularly-designed ring-and-pie electrode pattern. This aims to eliminate the disclination lines, and using different drive frequencies to reduce the recovery time to be less than 5 seconds. The proposed DFLC lens is shown effective in reducing recovery time, and then serves well as a potential device in places of the conventional lenses with fixed focus lengths and the conventional LC lens with a single circular-hole electrode pattern. PMID:22163906
A scheiner-principle vernier optometer
NASA Astrophysics Data System (ADS)
Cushman, William B.
1989-06-01
A method and optometer apparatus is disclosed for measuring the dark focus of accommodation. In a preferred embodiment, the optometer apparatus includes: a pinhole aperture plate having first and second horizontally positioned apertures disposed on opposite sides of a first optical axis; first and second orthogonally-oriented polarizing filters respectively covering the first and second horizontally positioned apertures; a positive lens having an optical axis on the first optical axis and being positioned at a distance of approximately one focal length from the pinhole aperture plate; a lens system having an optical axis on the first optical axis; a slit aperture plate having a vertical slit and being disposed on the first optical axis and between the positive lens and the lens system; third and fourth vertically positioned polarizing filters selectively disposed adjacent to the slit aperture plate to divide the slit vertically, a monochromatic light source for propagating light along the first optical axis through the lens system; and movable means attached to the slit aperture plate, the lens system and the monochromatic light source for moving the slit aperture plate.
To construct a stable and tunable optical trap in the focal region of a high numerical aperture lens
NASA Astrophysics Data System (ADS)
Kandasamy, Gokulakrishnan; Ponnan, Suresh; Sivasubramonia Pillai, T. V.; Balasundaram, Rajesh K.
2014-05-01
Based on the diffraction theory, the focusing properties of a radially polarized quadratic Bessel-Gaussian beam (QBG) with on-axis radial phase variance wavefront are investigated theoretically in the focal region of a high numerical aperture (NA) objective lens. The phase wavefront C and pupil beam parameter μ of QBG are the functions of the radial coordinate. The detailed numerical calculation of the focusing property of a QBG beam is presented. The numerical calculation shows that the beam parameter μ and phase parameter C have greater effect on the total electric field intensity distribution. It is observed that under the condition of different μ, evolution principle of focal pattern differs very remarkably on increasing C. Also, some different focal shapes may appear, including rhombic shape, quadrangular shape, two-spherical crust focus shape, two-peak shape, one dark hollow focus, two dark hollow focuses pattern, and triangle dark hollow focus, which find wide optical applications such as optical trapping and nanopatterning.
An electrostatic deceleration lens for highly charged ions.
Rajput, J; Roy, A; Kanjilal, D; Ahuja, R; Safvan, C P
2010-04-01
The design and implementation of a purely electrostatic deceleration lens used to obtain beams of highly charged ions at very low energies is presented. The design of the lens is such that it can be used with parallel as well as diverging incoming beams and delivers a well focused low energy beam at the target. In addition, tuning of the final energy of the beam over a wide range (1 eV/q to several hundred eV/q, where q is the beam charge state) is possible without any change in hardware configuration. The deceleration lens was tested with Ar(8+), extracted from an electron cyclotron resonance ion source, having an initial energy of 30 keV/q and final energies as low as 70 eV/q have been achieved.
Dual-polarity plasmonic metalens for visible light
NASA Astrophysics Data System (ADS)
Chen, Xianzhong; Huang, Lingling; Mühlenbernd, Holger; Li, Guixin; Bai, Benfeng; Tan, Qiaofeng; Jin, Guofan; Qiu, Cheng-Wei; Zhang, Shuang; Zentgraf, Thomas
2012-11-01
Surface topography and refractive index profile dictate the deterministic functionality of a lens. The polarity of most lenses reported so far, that is, either positive (convex) or negative (concave), depends on the curvatures of the interfaces. Here we experimentally demonstrate a counter-intuitive dual-polarity flat lens based on helicity-dependent phase discontinuities for circularly polarized light. Specifically, by controlling the helicity of the input light, the positive and negative polarity are interchangeable in one identical flat lens. Helicity-controllable real and virtual focal planes, as well as magnified and demagnified imaging, are observed on the same plasmonic lens at visible and near-infrared wavelengths. The plasmonic metalens with dual polarity may empower advanced research and applications in helicity-dependent focusing and imaging devices, angular-momentum-based quantum information processing and integrated nano-optoelectronics.
GRI: focusing on the evolving violent universe
NASA Astrophysics Data System (ADS)
Knödlseder, Jürgen; von Ballmoos, Peter; Frontera, Filippo; Bazzano, Angela; Christensen, Finn; Hernanz, Margarida; Wunderer, Cornelia
2009-03-01
The gamma-ray imager (GRI) is a novel mission concept that will provide an unprecedented sensitivity leap in the soft gamma-ray domain by using for the first time a focusing lens built of Laue diffracting crystals. The lens will cover an energy band from 200-1,300 keV with an effective area reaching 600 cm2. It will be complemented by a single reflection multilayer coated mirror, extending the GRI energy band into the hard X-ray regime, down to ˜10 keV. The concentrated photons will be collected by a position sensitive pixelised CZT stack detector. We estimate continuum sensitivities of better than 10 - 7 ph cm - 2s - 1keV - 1 for a 100 ks exposure; the narrow line sensitivity will be better than 3 × 10 - 6 ph cm - 2s - 1 for the same integration time. As focusing instrument, GRI will have an angular resolution of better than 30 arcsec within a field of view of roughly 5 arcmin—an unprecedented achievement in the gamma-ray domain. Owing to the large focal length of 100 m of the lens and the mirror, the optics and detector will be placed on two separate spacecrafts flying in formation in a high elliptical orbit. R&D work to enable the lens focusing technology and to develop the required focal plane detector is currently underway, financed by ASI, CNES, ESA, and the Spanish Ministery of Education and Science. The GRI mission has been proposed as class M mission for ESAs Cosmic Vision 2015-2025 program. GRI will allow studies of particle acceleration processes and explosion physics in unprecedented detail, providing essential clues on the innermost nature of the most violent and most energetic processes in the universe.
GRI: focusing on the evolving violent universe
NASA Astrophysics Data System (ADS)
Knödlseder, Jürgen; von Ballmoos, Peter; Frontera, Filippo; Bazzano, Angela; Christensen, Finn; Hernanz, Margarida; Wunderer, Cornelia
2007-09-01
The Gamma-Ray Imager (GRI) is a novel mission concept that will provide an unprecedented sensitivity leap in the soft gamma-ray domain by using for the first time a focusing lens built of Laue diffracting crystals. The lens will cover an energy band from 200 - 1300 keV with an effective area reaching 600 cm2. It will be complemented by a single reflection multilayer coated mirror, extending the GRI energy band into the hard X-ray regime, down to ~10 keV. The concentrated photons will be collected by a position sensitive pixelised CZT stack detector. We estimate continuum sensitivities of better than 10 -7 ph cm -2s -1keV -1 for a 100 ks exposure; the narrow line sensitivity will be better than 3 x 10 -6 ph cm -2s -1 for the same integration time. As focusing instrument, GRI will have an angular resolution of better than 30 arcsec within a field of view of roughly 5 arcmin - an unprecedented achievement in the gamma-ray domain. Owing to the large focal length of 100 m of the lens and the mirror, the optics and detector will be placed on two separate spacecrafts flying in formation in a high elliptical orbit. R&D work to enable the lens focusing technology and to develop the required focal plane detector is currently underway, financed by ASI, CNES, ESA, and the Spanish Ministery of Education and Science. The GRI mission is proposed as class M mission for ESA's Cosmic Vision 2015-2025 program. GRI will allow studies of particle acceleration processes and explosion physics in unprecedented detail, providing essential clues on the innermost nature of the most violent and most energetic processes in the Universe.
NASA Astrophysics Data System (ADS)
Malin, Michal C.; Ravine, Michael A.; Caplinger, Michael A.; Tony Ghaemi, F.; Schaffner, Jacob A.; Maki, Justin N.; Bell, James F.; Cameron, James F.; Dietrich, William E.; Edgett, Kenneth S.; Edwards, Laurence J.; Garvin, James B.; Hallet, Bernard; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sletten, Ron; Sullivan, Robert J.; Sumner, Dawn Y.; Aileen Yingst, R.; Duston, Brian M.; McNair, Sean; Jensen, Elsa H.
2017-08-01
The Mars Science Laboratory Mast camera and Descent Imager investigations were designed, built, and operated by Malin Space Science Systems of San Diego, CA. They share common electronics and focal plane designs but have different optics. There are two Mastcams of dissimilar focal length. The Mastcam-34 has an f/8, 34 mm focal length lens, and the M-100 an f/10, 100 mm focal length lens. The M-34 field of view is about 20° × 15° with an instantaneous field of view (IFOV) of 218 μrad; the M-100 field of view (FOV) is 6.8° × 5.1° with an IFOV of 74 μrad. The M-34 can focus from 0.5 m to infinity, and the M-100 from 1.6 m to infinity. All three cameras can acquire color images through a Bayer color filter array, and the Mastcams can also acquire images through seven science filters. Images are ≤1600 pixels wide by 1200 pixels tall. The Mastcams, mounted on the 2 m tall Remote Sensing Mast, have a 360° azimuth and 180° elevation field of regard. Mars Descent Imager is fixed-mounted to the bottom left front side of the rover at 66 cm above the surface. Its fixed focus lens is in focus from 2 m to infinity, but out of focus at 66 cm. The f/3 lens has a FOV of 70° by 52° across and along the direction of motion, with an IFOV of 0.76 mrad. All cameras can acquire video at 4 frames/second for full frames or 720p HD at 6 fps. Images can be processed using lossy Joint Photographic Experts Group and predictive lossless compression.
NASA Astrophysics Data System (ADS)
Xia, Yong; Yin, Jianping
2005-03-01
We propose a new scheme to generate a focusing hollow beam (FHB) by use of an azimuthally distributed 2π-phase plate and a convergent thin lens. From the Fresnel diffraction theory, we calculate the intensity distributions of the FHB in free propagation space and study the relationship between the waist w0 of the incident Gaussian beam (or the focal length f of the lens) and the dark spot size (or the beam radius) at the focal point and the relationship between the maximum radial intensity of the FHB and the dark spot size (or the beam radius) at the focal point, respectively. Our study shows that the FHB can be used to cool and trap neutral atoms by intensity-gradient-induced Sisyphus cooling due to an extremely high intensity gradient of the FHB itself near the focal point, or to guide and focus a cold molecular beam. We also calculate the optical potential of the blue-detuned FHB for 85Rb atoms and find that in the focal plane, the smaller the dark spot size of the FHB is, the higher the optical potential is, and the greater the corresponding optimal detuning δ is; these qualities are beneficial to an atomic lens not only because it is profitable to obtain an atomic lens with a higher resolution, but also because it is helpful to reduce the spontaneous photon-scattering effect of atoms in the FHB.
Meridional Modes and Increasing Pacific Decadal Variability Under Anthropogenic Forcing
NASA Astrophysics Data System (ADS)
Liguori, Giovanni; Di Lorenzo, Emanuele
2018-01-01
Pacific decadal variability has strong impacts on the statistics of weather, atmosphere extremes, droughts, hurricanes, marine heatwaves, and marine ecosystems. Sea surface temperature (SST) observations show that the variance of the El Niño-like decadal variability has increased by 30% (1920-2015) with a stronger coupling between the major Pacific climate modes. Although we cannot attribute these trends to global climate change, the examination of 30 members of the Community Earth System Model Large Ensemble (LENS) forced with the RCP8.5 radiative forcing scenario (1920-2100) suggests that significant anthropogenic trends in Pacific decadal variance will emerge by 2020 in response to a more energetic North Pacific Meridional Mode (PMM)—a well-known El Niño precursor. The PMM is a key mechanism for energizing and coupling tropical and extratropical decadal variability. In the LENS, the increase in PMM variance is consistent with an intensification of the winds-evaporation-SST thermodynamic feedback that results from a warmer mean climate.
... Read in Chinese How does the eye focus light? In order to see clearly, light rays from an object must focus onto the ... mechanism (the cornea and crystalline lens), and a light-sensing portion at the back (the retina). If ...
Extralenticular and Lenticular Aspects of Accommodation and Presbyopia in Human Versus Monkey Eyes
Croft, Mary Ann; McDonald, Jared P.; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.
2013-01-01
Purpose. To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components—muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above—are most important in predicting accommodative amplitude and presbyopia. Methods. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19–65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6–27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. Results. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Conclusions. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function. PMID:23745002
A PDMS-based cylindrical hybrid lens for enhanced fluorescence detection in microfluidic systems.
Lin, Bor-Shyh; Yang, Yu-Ching; Ho, Chong-Yi; Yang, Han-Yu; Wang, Hsiang-Yu
2014-02-13
Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.
Temporal integration of visual signals in lens compensation (a review)
Zhu, Xiaoying
2013-01-01
Postnatal eye growth is controlled by visual signals. When wearing a positive lens that causes images to be focused in front of the retina (myopic defocus), the eye reduces its rate of ocular elongation and increases choroidal thickness to move the retina forward to meet the focal plane of the eye. When wearing a negative lens that causes images to be focused behind the retina (hyperopic defocus), the opposite happens. This review summarizes how the retina integrates the constantly changing visual signals in a non-linear fashion to guide eye growth in chicks: (1a) When myopic or hyperopic defocus is interrupted by a daily episode of normal vision, normal vision is more effective in reducing myopia caused by hyperopic defocus than in reducing hyperopia caused by myopic defocus; (1b) when the eye experiences alternating myopic and hyperopic defocus, the eye is more sensitive to myopic defocus than to hyperopic defocus and tends to develop hyperopia, even if the duration of hyperopic defocus is much longer than the duration of myopic defocus; (2) when the eye experiences brief, repeated episodes of defocus by wearing either positive or negative lenses, lens compensation depends on the frequency and duration of individual episodes of lens wear, not just the total daily duration of lens wear; and (3) further analysis of the time constants for the hypothesized internal emmetropization signals show that, while it takes approximately the same amount of time for the signals to rise and saturate during lens-wearing episodes, the decline of the signals between episodes depends strongly on the sign of defocus and the ocular component. Although most extensively studied in chicks, the nonlinear temporal integration of visual signals has been found in other animal models. These findings may help explain the complex etiology of myopia in school-aged children and suggest ways to slow down myopia progression. PMID:23470505
Temporal integration of visual signals in lens compensation (a review).
Zhu, Xiaoying
2013-09-01
Postnatal eye growth is controlled by visual signals. When wearing a positive lens that causes images to be focused in front of the retina (myopic defocus), the eye reduces its rate of ocular elongation and increases choroidal thickness to move the retina forward to meet the focal plane of the eye. When wearing a negative lens that causes images to be focused behind the retina (hyperopic defocus), the opposite happens. This review summarizes how the retina integrates the constantly changing visual signals in a non-linear fashion to guide eye growth in chicks: (1a) When myopic or hyperopic defocus is interrupted by a daily episode of normal vision, normal vision is more effective in reducing myopia caused by hyperopic defocus than in reducing hyperopia caused by myopic defocus; (1b) when the eye experiences alternating myopic and hyperopic defocus, the eye is more sensitive to myopic defocus than to hyperopic defocus and tends to develop hyperopia, even if the duration of hyperopic defocus is much longer than the duration of myopic defocus; (2) when the eye experiences brief, repeated episodes of defocus by wearing either positive or negative lenses, lens compensation depends on the frequency and duration of individual episodes of lens wear, not just the total daily duration of lens wear; and (3) further analysis of the time constants for the hypothesized internal emmetropization signals show that, while it takes approximately the same amount of time for the signals to rise and saturate during lens-wearing episodes, the decline of the signals between episodes depends strongly on the sign of defocus and the ocular component. Although most extensively studied in chicks, the nonlinear temporal integration of visual signals has been found in other animal models. These findings may help explain the complex etiology of myopia in school-aged children and suggest ways to slow down myopia progression. Copyright © 2013 Elsevier Ltd. All rights reserved.
A gravitational lens candidate with an unusually red optical counterpart
NASA Technical Reports Server (NTRS)
Hewitt, J. N.; Turner, E. L.; Lawrence, C. R.; Schneider, D. P.; Brody, J. P.
1992-01-01
The properties of the strong radio source MG0414 + 0534 are described. It is found to display many of the properties expected in a gravitational lens system. At radio wavelengths and 0.5-arcsec resolution, MG0414 + 0534 is made up of four compact components whose unusual configuration and relative flux densities are similar to those found in confirmed four-image gravitational lens systems. At optical wavelengths three objects are detected, consistent with there being optical objects at the positions of the radio components, given the lower optical resolution. The radio and optical centroid positions agree within the astrometric errors, and the relative ordering of the fluxes is the same. The colors and radiooptical spectral indices are similar, but there are differences larger than the photometric errors and the measured variability (about 30 percent). Extinction by dust might simultaneously explain the unusually red color and the absence of light from a lens.
Gelatt, K N; Samuelson, D A; Barrie, K P; Das, N D; Wolf, E D; Bauer, J E; Andresen, T L
1983-07-01
Forty-two Miniature Schnauzer pups and adults with congenital cataracts and microphthalmia were evaluated by serial ophthalmic examinations, slit lamp biomicroscopic photography, and A-scan ultrasonography. The cataracts were evident when the eyelids opened at 2 weeks, affecting predominantly the lens nucleus and posterior cortex. Lenticonus was evident in 19% of the cataractous lenses. Progression of the cataracts was variable and related to involvement of the equatorial and posterior cortices. Lens-induced uveitis developed in some adult dogs with advanced hypermature cataracts. The globe and lens were smaller than normal in the cataractous eyes, as ascertained by A-scan ultrasonography. Age-matched comparisons of clear lens carrier Miniature Schnauzers and normal Beagles with the cataractous Miniature Schnauzers indicated affected globes and cataractous lenses were reduced 10% to 20% in their anteroposterior lengths. The microphthalmia appeared related to the congenital microphakic cataract.
Suspension and optical properties of the crystalline lens in the eyes of basal vertebrates.
Kröger, Ronald H H; Gustafsson, Ola S E; Tuminaite, Inga
2014-06-01
We have investigated the apparatus suspending the crystalline lens in the eyes of basal vertebrates. Data are presented for Holocephali (Chondrichthyes) and the actinopterygians Polypteriformes, Polyodontidae (Acipenseriformes), Lepisosteiformes, Amiiformes, and one teleost species, the banded archerfish (Toxotes jaculatrix). We also studied the optical properties of the lens in Polypteriformes, Lepisosteiformes, and the archerfish. Together with previously published results, our findings show that there are three basic types of lens suspension in vertebrates. These are i) a rotationally symmetric suspension (Petromyzontida, lampreys; Ceratodontiformes, lungfishes; Tetrapoda), ii) a suspension with a dorso-ventral axis of symmetry and a ventral papilla (all Chondrichthyes and Acipenseriformes), and iii) an asymmetric suspension with a ventral muscle and a varying number of ligaments (all Actinopterygii except for Acipenseriformes). Large eyes with presumably high spatial resolution have evolved in all groups. Multifocal lenses creating well-focused color images are also present in all groups studied. Stable and exact positioning of the lens, in many cases in combination with accommodative changes in lens position or shape, is achieved by all three types of lens suspension. It is somewhat surprising that lens suspensions are strikingly similar in Chondrichthyes and Acipenseriformes (Actinopterygii), while the suspension apparatus in Polypteriformes, usually being regarded as an actinopterygian group more basal than Acipenseriformes, are considerably more teleostean-like. This study completes a series of investigations on lens suspensions in nontetrapod vertebrates, covering all major groups except for the rare and highly derived coelacanths. Copyright © 2013 Wiley Periodicals, Inc.
A CPV System with Static Linear Fresnel Lenses in a Greenhouse
NASA Astrophysics Data System (ADS)
Sonneveld, Piet; Zahn, Helmut; Swinkels, Gert-Jan
2010-10-01
A new CPV system with a static linear Fresnel lens, silicon PV module suitable for concentrated radiation and an innovative tracking system is integrated in a greenhouse covering. The basic idea of this horticultural application is to develop a greenhouse for pot plants (typical shadow plants) which don't like high direct radiation. Removing all direct radiation will block up to 77% of the solar energy, which will reduce the necessary cooling capacity. The solar energy focused on the Thermal Photovoltaic (PV/T) module generates electric and thermal energy. The PV/T module is tracked in the focal line and requires cooling due to the high heat load of the concentrated radiation (concentration factor of 50 times). All parts are integrated in a greenhouse with a size of about 36 m2. The electrical and thermal yield is determined for Dutch climate circumstances. Some measurements were performed with a PMMA linear Fresnel lens between double glass. Further improvement of the performance of the CPV-system is possible by using a PDMS lens directly laminated on glass and using AR-coated glass. This lens is developed with ZEMAX and the results of the Ray-tracing simulations are presented with the lens structure oriented in an upwards and downwards position. The best performance of the static linear Fresnel lens is achieved with upwards orientation of the lens structures. In practice this is only possible with the Fresnel lens placed between a double glass structure, which will keep the lens clean and free of water.
Statistical simplex approach to primary and secondary color correction in thick lens assemblies
NASA Astrophysics Data System (ADS)
Ament, Shelby D. V.; Pfisterer, Richard
2017-11-01
A glass selection optimization algorithm is developed for primary and secondary color correction in thick lens systems. The approach is based on the downhill simplex method, and requires manipulation of the surface color equations to obtain a single glass-dependent parameter for each lens element. Linear correlation is used to relate this parameter to all other glass-dependent variables. The algorithm provides a statistical distribution of Abbe numbers for each element in the system. Examples of several lenses, from 2-element to 6-element systems, are performed to verify this approach. The optimization algorithm proposed is capable of finding glass solutions with high color correction without requiring an exhaustive search of the glass catalog.
Electromagnetic field focusing by a plane multilayer structure with a Veselago medium
NASA Astrophysics Data System (ADS)
Fisanov, V. V.
2011-12-01
The focusing properties of a system of plane layers of a Veselago medium divided by vacuous intervals are investigated by the coordinate transformation method. The role of real and virtual foci in the mechanism of focusing by a multilayered lens is considered.
Pinhole Cameras: For Science, Art, and Fun!
ERIC Educational Resources Information Center
Button, Clare
2007-01-01
A pinhole camera is a camera without a lens. A tiny hole replaces the lens, and light is allowed to come in for short amount of time by means of a hand-operated shutter. The pinhole allows only a very narrow beam of light to enter, which reduces confusion due to scattered light on the film. This results in an image that is focused, reversed, and…
Ti/Al multilayer zone plate and Bragg-Fresnel lens.
Koike, M; Suzuki, I H; Komiya, S; Amemiya, Y
1998-05-01
By using a helicon plasma sputtering technique, a one-dimensional Ti/Al multilayer zone plate with an outermost layer width of 76 nm has been successfully fabricated. A Bragg-Fresnel lens has been made by combining this zone plate with a Ge(422) crystal. Comparison of the Ti/Al multilayer zone plate with the Ag/Al zone plate is discussed in terms of focusing efficiency.
ERIC Educational Resources Information Center
Schultz-Jones, Barbara; Faber, Toby; Reed, Jan
2010-01-01
We examined the issues related to delivering service excellence through the lens of 39 graduating school librarians in written assignments for the final course of their certification program, as they focus on what is needed to apply standards to become an effective school library media specialist in the 21st century. Of the 16 issues identified,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duwel, D; Lamba, M; Elson, H
Purpose: Various cancers of the eye are successfully treated with radiotherapy utilizing one anterior-posterior (A/P) beam that encompasses the entire content of the orbit. In such cases, a hanging lens shield can be used to spare dose to the radiosensitive lens of the eye to prevent cataracts. Methods: This research focused on Monte Carlo characterization of dose distributions resulting from a single A-P field to the orbit with a hanging shield in place. Monte Carlo codes were developed which calculated dose distributions for various electron radiation energies, hanging lens shield radii, shield heights above the eye, and beam spoiler configurations.more » Film dosimetry was used to benchmark the coding to ensure it was calculating relative dose accurately. Results: The Monte Carlo dose calculations indicated that lateral and depth dose profiles are insensitive to changes in shield height and electron beam energy. Dose deposition was sensitive to shield radius and beam spoiler composition and height above the eye. Conclusion: The use of a single A/P electron beam to treat cancers of the eye while maintaining adequate lens sparing is feasible. Shield radius should be customized to have the same radius as the patient’s lens. A beam spoiler should be used if it is desired to substantially dose the eye tissues lying posterior to the lens in the shadow of the lens shield. The compromise between lens sparing and dose to diseased tissues surrounding the lens can be modulated by varying the beam spoiler thickness, spoiler material composition, and spoiler height above the eye. The sparing ratio is a metric that can be used to evaluate the compromise between lens sparing and dose to surrounding tissues. The higher the ratio, the more dose received by the tissues immediately posterior to the lens relative to the dose received by the lens.« less
Sant'Anna, Neusa Vidal; Schor, Paulo; Lipener, César; Uras, Ricardo
2006-01-01
To compare the visual function and the answers to a questionnaire of quality of life of patients wearing a progressive contact lens or eyeglasses. The Focus Progressive contact lens had been fitted in 35 patients with far visual acuity with progressive-addition eyeglasses equal to zero (log MAR) and near J1 (Jaeger). The far and near visual acuities and the measurement of contrast sensitivity were compared when the patients were wearing the eyeglasses or the contact lens and the patients' results of the scores of the quality of life questionnaire (NEI VFQ-25) were analyzed statistically considering the type of ametropy and the age. The far and near visual acuities and the contrast sensitivity measurement were worse with the contact lens than with eyeglasses. The answers to the questionnaire did not differ when were comparing the same patients wearing eyeglasses or contact lens, no matter the type of ametropy. The myopic and the hyperopic subgroups had worse answers to the quality of life questionnaire when corrected with the contact lens than with eyeglasses, both with age equal to or less than their median. The visual function was worse with the contact lens. The type of ametropy did not influence the answers to the quality of life questionnaire considering the optical correction, but age did.
A study of GeV proton microprobe lens system designs with normal magnetic quadrupole
NASA Astrophysics Data System (ADS)
Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi
2017-12-01
High energy proton irradiation has many applications to the study of radiation effects in semiconductor devices, biological tissues, proton tomography and space science. Many applications could be extended and enhanced by use of a high energy proton microprobe. However the design of a GeV proton microprobe must address significant challenges including beam collimation that minimizes ion scattering and the probe forming lens system for ions of high rigidity. Here we address the probe forming lens system design subject to several practical constraints including the use of non-superconducting normal magnetic quadrupole lenses, the ability to focus 1-5 GeV protons into 5 μm diameter microprobes and compatibility with the beam parameters of GeV proton accelerators. We show that 2, 3 and 4 lens systems of lenses with effective lengths up to 0.63 m can be employed for this purpose with a demagnification up to 58 and investigate the probe size limitations from beam brightness, lens aberrations and machining precision.
Solutions on a high-speed wide-angle zoom lens with aspheric surfaces
NASA Astrophysics Data System (ADS)
Yamanashi, Takanori
2012-10-01
Recent development in CMOS and digital camera technology has accelerated the business and market share of digital cinematography. In terms of optical design, this technology has increased the need to carefully consider pixel pitch and characteristics of the imager. When the field angle at the wide end, zoom ratio, and F-number are specified, choosing an appropriate zoom lens type is crucial. In addition, appropriate power distributions and lens configurations are required. At points near the wide end of a zoom lens, it is known that an aspheric surface is an effective means to correct off-axis aberrations. On the other hand, optical designers have to focus on manufacturability of aspheric surfaces and perform required analysis with respect to the surface shape. Centration errors aside, it is also important to know the sensitivity to aspheric shape errors and their effect on image quality. In this paper, wide angle cine zoom lens design examples are introduced and their main characteristics are described. Moreover, technical challenges are pointed out and solutions are proposed.
High convergence efficiency design of flat Fresnel lens with large aperture
NASA Astrophysics Data System (ADS)
Ke, Jieyao; Zhao, Changming; Guan, Zhe
2018-01-01
This paper designed a circle-shaped Fresnel lens with large aperture as part of the solar pumped laser design project. The Fresnel lens designed in this paper simulate in size 1000mm×1000mm, focus length 1200mm and polymethyl methacrylate (PMMA) material in order to conduct high convergence efficiency. In the light of design requirement of concentric ring with same width of 0.3mm, this paper proposed an optimized Fresnel lens design based on previous sphere design and conduct light tracing simulation in Matlab. This paper also analyzed the effect of light spot size, light intensity distribution, optical efficiency under four conditions, monochromatic parallel light, parallel spectrum light, divergent monochromatic light and sunlight. Design by 550nm wavelength and under the condition of Fresnel reflection, the results indicated that the designed lens could convergent sunlight in diffraction limit of 11.8mm with a 78.7% optical efficiency, better than the sphere cutting design results of 30.4%.
Acoustic focusing by symmetrical self-bending beams with phase modulations
NASA Astrophysics Data System (ADS)
Gao, He; Gu, Zhong-ming; Liang, Bin; Zou, Xin-ye; Yang, Jing; Yang, Jun; Cheng, Jian-chun
2016-02-01
We propose a scheme for generating high-efficient acoustic focusing capable of circumventing obstacles in the propagating medium. This distinct feature that is highly desirable for practical applications is realized by employing two symmetrical Airy beams, and a different type of acoustic lens is designed by using a zero-index medium to provide the required phase profile with extremely high resolution. Furthermore, the scheme has the flexibility of generating tunable focal length. We anticipate our design to open possibilities for the design of acoustic lens and have potential applications in various important scenarios such as biomedical imaging/therapy and non-destructive evaluation.
Portable instrument for inspecting irradiated nuclear fuel assemblies
Nicholson, Nicholas; Dowdy, Edward J.; Holt, David M.; Stump, Jr., Charles J.
1985-01-01
A portable instrument for measuring induced Cerenkov radiation associated with irradiated nuclear fuel assemblies in a water-filled storage pond is disclosed. The instrument includes a photomultiplier tube and an image intensifier which are operable in parallel and simultaneously by means of a field lens assembly and an associated beam splitter. The image intensifier permits an operator to aim and focus the apparatus on a submerged fuel assembly. Once the instrument is aimed and focused, an illumination reading can be obtained with the photomultiplier tube. The instrument includes a lens cap with a carbon-14/phosphor light source for calibrating the apparatus in the field.
Silicon saw-tooth refractive lens for high-energy x-rays made using a diamond saw.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Said, A. H.; Shastri, S. D.; X-Ray Science Division
2010-01-01
Silicon is a material well suited for refractive lenses operating at high X-ray energies (>50 keV), particularly if implemented in a single-crystal form to minimize small-angle scattering. A single-crystal silicon saw-tooth refractive lens, fabricated by a dicing process using a thin diamond wheel, was tested with 115 keV X-rays, giving an ideal 17 {mu}m line focus width in a long focal length, 2:1 ratio demagnification geometry, with a source-to-focus distance of 58.5 m. The fabrication is simple, using resources typically available at any synchrotron facility's optics shop.
Field modeling and ray-tracing of a miniature scanning electron microscope beam column.
Loyd, Jody S; Gregory, Don A; Gaskin, Jessica A
2017-08-01
A miniature scanning electron microscope (SEM) focusing column design is introduced and its potential performance assessed through an estimation of parameters that affect the probe radius, to include source size, spherical and chromatic aberration, diffraction and space charge broadening. The focusing column, a critical component of any SEM capable of operating on the lunar surface, was developed by the NASA Marshall Space Flight Center and Advanced Research Systems. The ray-trace analysis presented uses a model of the electrostatic field (within the focusing column) that is first calculated using the boundary element method (BEM). This method provides flexibility in modeling the complex electrode shapes of practical electron lens systems. A Fourier series solution of the lens field is then derived within a cylindrical domain whose boundary potential is provided by the BEM. Used in this way, the Fourier series solution is an accuracy enhancement to the BEM solution, allowing sufficient precision to assess geometric aberrations through direct ray-tracing. Two modes of operation with distinct lens field solutions are described. © The Author 2017. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Single-crystal diamond refractive lens for focusing X-rays in two dimensions.
Antipov, S; Baryshev, S V; Butler, J E; Antipova, O; Liu, Z; Stoupin, S
2016-01-01
The fabrication and performance evaluation of single-crystal diamond refractive X-ray lenses of which the surfaces are paraboloids of revolution for focusing X-rays in two dimensions simultaneously are reported. The lenses were manufactured using a femtosecond laser micromachining process and tested using X-ray synchrotron radiation. Such lenses were stacked together to form a standard compound refractive lens (CRL). Owing to the superior physical properties of the material, diamond CRLs could become indispensable wavefront-preserving primary focusing optics for X-ray free-electron lasers and the next-generation synchrotron storage rings. They can be used for highly efficient refocusing of the extremely bright X-ray sources for secondary optical schemes with limited aperture such as nanofocusing Fresnel zone plates and multilayer Laue lenses.
Single-crystal diamond refractive lens for focusing X-rays in two dimensions
Antipov, S.; Baryshev, S. V.; Butler, J. E.; Antipova, O.; Liu, Z.; Stoupin, S.
2016-01-01
The fabrication and performance evaluation of single-crystal diamond refractive X-ray lenses of which the surfaces are paraboloids of revolution for focusing X-rays in two dimensions simultaneously are reported. The lenses were manufactured using a femtosecond laser micromachining process and tested using X-ray synchrotron radiation. Such lenses were stacked together to form a standard compound refractive lens (CRL). Owing to the superior physical properties of the material, diamond CRLs could become indispensable wavefront-preserving primary focusing optics for X-ray free-electron lasers and the next-generation synchrotron storage rings. They can be used for highly efficient refocusing of the extremely bright X-ray sources for secondary optical schemes with limited aperture such as nanofocusing Fresnel zone plates and multilayer Laue lenses. PMID:26698059
Single-crystal diamond refractive lens for focusing X-rays in two dimensions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antipov, S.; Baryshev, Sergey; Butler, J. E.
2016-01-01
The fabrication and performance evaluation of single-crystal diamond refractive X-ray lenses of which the surfaces are paraboloids of revolution for focusing X-rays in two dimensions simultaneously are reported. The lenses were manufactured using a femtosecond laser micromachining process and tested using X-ray synchrotron radiation. Such lenses were stacked together to form a standard compound refractive lens (CRL). Owing to the superior physical properties of the material, diamond CRLs could become indispensable wavefront-preserving primary focusing optics for X-ray free-electron lasers and the next-generation synchrotron storage rings. They can be used for highly efficient refocusing of the extremely bright X-ray sources formore » secondary optical schemes with limited aperture such as nanofocusing Fresnel zone plates and multilayer Laue lenses.« less
Focusing of light by polymer-dispersed liquid-crystal films with nanosized droplets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loiko, V. A., E-mail: loiko@dragon.bas-net.by; Konkolovich, A. V.
2006-12-15
An analysis is presented of polarization-independent electrically tunable light focusing by polymerdispersed liquid-crystal films with nanosized liquid-crystal droplets. Polymer-dispersed liquid-crystal films with axially symmetric distributions of liquid-crystal droplet concentration and layers with axially symmetric thickness profiles are considered. The paraxial, Rayleigh, and Rayleigh-Gans approximations, as well as the Foldy-Twersky equation, are used to examine the dependence of focal length on lens geometry, droplet size, concentration of nematic liquid-crystal droplets, and applied field. The tunable focusing ranges are evaluated for both lens types considered in the study. Dependence of the transmittance of polymer-dispersed liquid-crystal film on its characteristics is analyzed. Themore » results obtained are compared with those available from the literature.« less
Tunable-Bandwidth Filter System
NASA Technical Reports Server (NTRS)
Bailey, John W.
2004-01-01
A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.
Tunable-Bandwidth Filter System
NASA Technical Reports Server (NTRS)
Aye, Tin; Yu, Kevin; Dimov, Fedor; Savant, Gajendra
2006-01-01
A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.
Kaye, Stephen B
2009-04-01
To provide a scalar measure of refractive error, based on geometric lens power through principal, orthogonal and oblique meridians, that is not limited to the paraxial and sag height approximations. A function is derived to model sections through the principal meridian of a lens, followed by rotation of the section through orthogonal and oblique meridians. Average focal length is determined using the definition for the average of a function. Average univariate power in the principal meridian (including spherical aberration), can be computed from the average of a function over the angle of incidence as determined by the parameters of the given lens, or adequately computed from an integrated series function. Average power through orthogonal and oblique meridians, can be similarly determined using the derived formulae. The widely used computation for measuring refractive error, the spherical equivalent, introduces non-constant approximations, leading to a systematic bias. The equations proposed provide a good univariate representation of average lens power and are not subject to a systematic bias. They are particularly useful for the analysis of aggregate data, correlating with biological treatment variables and for developing analyses, which require a scalar equivalent representation of refractive power.
Terahertz Artificial Dielectric Lens.
Mendis, Rajind; Nagai, Masaya; Wang, Yiqiu; Karl, Nicholas; Mittleman, Daniel M
2016-03-14
We have designed, fabricated, and experimentally characterized a lens for the THz regime based on artificial dielectrics. These are man-made media that mimic properties of naturally occurring dielectric media, or even manifest properties that cannot generally occur in nature. For example, the well-known dielectric property, the refractive index, which usually has a value greater than unity, can have a value less than unity in an artificial dielectric. For our lens, the artificial-dielectric medium is made up of a parallel stack of 100 μm thick metal plates that form an array of parallel-plate waveguides. The convergent lens has a plano-concave geometry, in contrast to conventional dielectric lenses. Our results demonstrate that this lens is capable of focusing a 2 cm diameter beam to a spot size of 4 mm, at the design frequency of 0.17 THz. The results further demonstrate that the overall power transmission of the lens can be better than certain conventional dielectric lenses commonly used in the THz regime. Intriguingly, we also observe that under certain conditions, the lens boundary demarcated by the discontinuous plate edges actually resembles a smooth continuous surface. These results highlight the importance of this artificial-dielectric technology for the development of future THz-wave devices.
Terahertz Artificial Dielectric Lens
Mendis, Rajind; Nagai, Masaya; Wang, Yiqiu; Karl, Nicholas; Mittleman, Daniel M.
2016-01-01
We have designed, fabricated, and experimentally characterized a lens for the THz regime based on artificial dielectrics. These are man-made media that mimic properties of naturally occurring dielectric media, or even manifest properties that cannot generally occur in nature. For example, the well-known dielectric property, the refractive index, which usually has a value greater than unity, can have a value less than unity in an artificial dielectric. For our lens, the artificial-dielectric medium is made up of a parallel stack of 100 μm thick metal plates that form an array of parallel-plate waveguides. The convergent lens has a plano-concave geometry, in contrast to conventional dielectric lenses. Our results demonstrate that this lens is capable of focusing a 2 cm diameter beam to a spot size of 4 mm, at the design frequency of 0.17 THz. The results further demonstrate that the overall power transmission of the lens can be better than certain conventional dielectric lenses commonly used in the THz regime. Intriguingly, we also observe that under certain conditions, the lens boundary demarcated by the discontinuous plate edges actually resembles a smooth continuous surface. These results highlight the importance of this artificial-dielectric technology for the development of future THz-wave devices. PMID:26973294
Thermoacoustic focusing lens by symmetric Airy beams with phase manipulations
NASA Astrophysics Data System (ADS)
Liu, Chen; Xia, Jian-Ping; Sun, Hong-Xiang; Yuan, Shou-Qi
2017-12-01
We report the realization of broadband acoustic focusing lenses based on two symmetric thermoacoustic phased arrays of Airy beams, in which the units of thermoacoustic phase control are designed by employing air with different temperatures surrounded by rigid insulated boundaries and thermal insulation films. The phase delays of the transmitted and reflected units could cover a whole 2π interval, which arises from the change of the sound velocity of air induced by the variation of the temperature. Based on the units of phase control, we design the transmitted and reflected acoustic focusing lenses with two symmetric Airy beams, and verify the high self-healing focusing characteristic and the feasibility of the thermal insulation films. Besides, the influences of the bending angle of the Airy beam on the focusing performance are discussed in detail. The proposed acoustic lens has advantages of broad bandwidth (about 4.8 kHz), high focusing performance, self-healing feature, and simple structure, which enable it to provide more schemes for acoustic focusing. It has excellent potential applications in acoustic devices.
Lens elliptic gamma function solution of the Yang-Baxter equation at roots of unity
NASA Astrophysics Data System (ADS)
Kels, Andrew P.; Yamazaki, Masahito
2018-02-01
We study the root of unity limit of the lens elliptic gamma function solution of the star-triangle relation, for an integrable model with continuous and discrete spin variables. This limit involves taking an elliptic nome to a primitive rNth root of unity, where r is an existing integer parameter of the lens elliptic gamma function, and N is an additional integer parameter. This is a singular limit of the star-triangle relation, and at subleading order of an asymptotic expansion, another star-triangle relation is obtained for a model with discrete spin variables in {Z}rN . Some special choices of solutions of equation of motion are shown to result in well-known discrete spin solutions of the star-triangle relation. The saddle point equations themselves are identified with three-leg forms of ‘3D-consistent’ classical discrete integrable equations, known as Q4 and Q3(δ=0) . We also comment on the implications for supersymmetric gauge theories, and in particular comment on a close parallel with the works of Nekrasov and Shatashvili.
Beach, Raymond J.; Honea, Eric C.; Bibeau, Camille; Mitchell, Scott; Lang, John; Maderas, Dennis; Speth, Joel; Payne, Stephen A.
2000-01-01
A hollow lensing duct to condense (intensify) light using a combination of focusing using a spherical or cylindrical lens followed by reflective waveguiding. The hollow duct tapers down from a wide input side to a narrow output side, with the input side consisting of a lens that may be coated with an antireflective coating for more efficient transmission into the duct. The inside surfaces of the hollow lens duct are appropriately coated to be reflective, preventing light from escaping by reflection as it travels along the duct (reflective waveguiding). The hollow duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials.
Efficient flat metasurface lens for terahertz imaging.
Yang, Quanlong; Gu, Jianqiang; Wang, Dongyang; Zhang, Xueqian; Tian, Zhen; Ouyang, Chunmei; Singh, Ranjan; Han, Jiaguang; Zhang, Weili
2014-10-20
Metamaterials offer exciting opportunities that enable precise control of amplitude, polarization and phase of the light beam at a subwavelength scale. A gradient metasurface consists of a class of anisotropic subwavelength metamaterial resonators that offer abrupt amplitude and phase changes, thus enabling new applications in optical device design such as ultrathin flat lenses. We propose a highly efficient gradient metasurface lens based on a metal-dielectric-metal structure that operates in the terahertz regime. The proposed structure consists of slotted metallic resonator arrays on two sides of a thin dielectric spacer. By varying the geometrical parameters, the metasurface lens efficiently manipulates the spatial distribution of the terahertz field and focuses the beam to a spot size on the order of a wavelength. The proposed flat metasurface lens design is polarization insensitive and works efficiently even at wide angles of incidence.
A general purpose wideband optical spatial frequency spectrum analyzer
NASA Technical Reports Server (NTRS)
Ballard, G. S.; Mellor, F. A.
1972-01-01
The light scattered at various angles by a transparent media is studied. An example of these applications is the optical Fourier spectrum measurement resulting from various spatial frequencies which were recorded on a photographic emulsion. A method for obtaining these measurements consists of illuminating the test object with parallel monochromatic light. A stationary lens, placed in the resulting wavefield at a distance of one focal length from the object, will focus parallel waves emanating from the test object at a point lying in the focal plane of the lens. A light detector with a small filtering aperture is then used to measure the intensity variation of the light in the focal or transform plane of the lens. Such measurements require the use of a lens which is highly corrected for all of the common aberrations except chromatic aberration.
Huang, Zhihua; Wei, Xiaofeng; Li, Mingzhong; Wang, Jianjun; Lin, Honghuan; Xu, Dangpeng; Deng, Ying; Zhang, Rui
2012-04-01
Coherent and incoherent combination of Gaussian beams employing a lens array distributed on the spherical chamber is theoretically analyzed. The output field of each source in the array is coupled through an individual optical system whose local optical axis coincides with the radial direction of the chamber. The resulting intensity profile near the origin is derived. The intensity profile and power in the bucket on the target for rectangular and hexagonal arrangement are numerically calculated. The influences of the center-to-center separation and the ring number of the focusing lens array are given. The synthetic intensity profile of incoherent combination changes little for a lens array scale much smaller than the chamber size. In contrast, the synthetic intensity profile of coherent combination shows an interference pattern with a sharp central peak and sidelobes.
Herwig, Martina C; Müller, Annette M; Klarmann-Schulz, Ute; Holz, Frank G; Loeffler, Karin U
2014-01-01
Evaluation of the lens, including cataractous changes, is often of paramount importance in the classification of fetal syndromes or forensic questions. On histology, the crystalline lens is - especially in fetal and infant eyes - an organ susceptible to numerous artifacts. Thus, the aim of our study was to study various factors (including fixatives) that might have an impact on lens histomorphology. Twenty eyes from ten fetuses (formalin fixation: n = 10, glutaraldehyde fixation: n = 10), matched for gestational age and abortion (spontaneous vs. induced), were investigated macroscopically and by light microscopy. Sections were stained with routine hematoxylin & eosin (H&E), and periodic acid schiff (PAS). The age of the fetal eyes ranged from 15 to 36 weeks of gestation. Lens artifacts were analyzed and compared to fetal and adult lenses with definitive cataractous changes. In addition, 34 eyes from 27 fetuses with trisomy 21 were investigated for lens changes. All lenses showed artifacts of varying extent, in particular globules, vacuoles, clefts, anterior/posterior capsular separation, subcapsular proteinaceous material, fragmentation of the lens capsule/epithelium, and a posterior umbilication. Glutaraldehyde-fixed lenses displayed less artifacts compared to those fixed in formalin. Slight differences in the appearance of artifacts were found dependent on the fixative (formaldehyde vs glutaraldehyde) and the kind of abortion (iatrogenous vs spontaneous). The gestational age did not have a significant influence on the type and extent of lens artifacts. The lenses from fetuses with trisomy 21 displayed similar lens artifacts with no specific findings. Alterations in fetal lens morphology are extremely frequent and variable. These artifacts have to be carefully taken into account when interpreting post-mortem findings. Thus, the postmortem diagnosis of a fetal cataract should be made with great caution, and should include, in adherence to our proposed diagnostic flow diagram, the macroscopic lens assessment. Reference slides with a proven cataract are recommended for comparison in equivocal cases.
Mode-mismatched confocal thermal-lens microscope with collimated probe beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabrera, Humberto, E-mail: hcabrera@ictp.it; Centro Multidisciplinartio de Ciencias, Instituto Venezolano de Investigaciones Científicas; Korte, Dorota
2015-05-15
We report a thermal lens microscope (TLM) based on an optimized mode-mismatched configuration. It takes advantage of the coaxial counter propagating tightly focused excitation and collimated probe beams, instead of both focused at the sample, as it is in currently known TLM setups. A simple mathematical model that takes into account the main features of the instrument is presented. The confocal detection scheme and the introduction of highly collimated probe beam allow enhancing the versatility, limit of detection (LOD), and sensitivity of the instrument. The theory is experimentally verified measuring ethanol’s absorption coefficient at 532.8 nm. Additionally, the presented techniquemore » is applied for detection of ultra-trace amounts of Cr(III) in liquid solution. The achieved LOD is 1.3 ppb, which represents 20-fold enhancement compared to transmission mode spectrometric techniques and a 7.5-fold improvement compared to previously reported methods for Cr(III) based on thermal lens effect.« less
Stereo multiplexed holographic particle image velocimeter
Adrian, Ronald J.; Barnhart, Donald H.; Papen, George A.
1996-01-01
A holographic particle image velocimeter employs stereoscopic recording of particle images, taken from two different perspectives and at two distinct points in time for each perspective, on a single holographic film plate. The different perspectives are provided by two optical assemblies, each including a collecting lens, a prism and a focusing lens. Collimated laser energy is pulsed through a fluid stream, with elements carried in the stream scattering light, some of which is collected by each collecting lens. The respective focusing lenses are configured to form images of the scattered light near the holographic plate. The particle images stored on the plate are reconstructed using the same optical assemblies employed in recording, by transferring the film plate and optical assemblies as a single integral unit to a reconstruction site. At the reconstruction site, reconstruction beams, phase conjugates of the reference beams used in recording the image, are directed to the plate, then selectively through either one of the optical assemblies, to form an image reflecting the chosen perspective at the two points in time.
Stereo multiplexed holographic particle image velocimeter
Adrian, R.J.; Barnhart, D.H.; Papen, G.A.
1996-08-20
A holographic particle image velocimeter employs stereoscopic recording of particle images, taken from two different perspectives and at two distinct points in time for each perspective, on a single holographic film plate. The different perspectives are provided by two optical assemblies, each including a collecting lens, a prism and a focusing lens. Collimated laser energy is pulsed through a fluid stream, with elements carried in the stream scattering light, some of which is collected by each collecting lens. The respective focusing lenses are configured to form images of the scattered light near the holographic plate. The particle images stored on the plate are reconstructed using the same optical assemblies employed in recording, by transferring the film plate and optical assemblies as a single integral unit to a reconstruction site. At the reconstruction site, reconstruction beams, phase conjugates of the reference beams used in recording the image, are directed to the plate, then selectively through either one of the optical assemblies, to form an image reflecting the chosen perspective at the two points in time. 13 figs.
ERIC Educational Resources Information Center
Koretz, Jane F.; Handelman, George H.
1988-01-01
Describes the decline in people's ability to focus their eyes as their age increases. Discusses probable causes of this effect including changes in the eye's geometry and biochemistry. Diagrammatically illustrates age related changes in the lens of the human eye. (CW)
Colquitt, Jason A; Scott, Brent A; Rodell, Jessica B; Long, David M; Zapata, Cindy P; Conlon, Donald E; Wesson, Michael J
2013-03-01
Although a flurry of meta-analyses summarized the justice literature at the turn of the millennium, interest in the topic has surged in the decade since. In particular, the past decade has witnessed the rise of social exchange theory as the dominant lens for examining reactions to justice, and the emergence of affect as a complementary lens for understanding such reactions. The purpose of this meta-analytic review was to test direct, mediating, and moderating hypotheses that were inspired by those 2 perspectives, to gauge their adequacy as theoretical guides for justice research. Drawing on a review of 493 independent samples, our findings revealed a number of insights that were not included in prior meta-analyses. With respect to social exchange theory, our results revealed that the significant relationships between justice and both task performance and citizenship behavior were mediated by indicators of social exchange quality (trust, organizational commitment, perceived organizational support, and leader-member exchange), though such mediation was not apparent for counterproductive behavior. The strength of those relationships did not vary according to whether the focus of the justice matched the target of the performance behavior, contrary to popular assumptions in the literature, or according to whether justice was referenced to a specific event or a more general entity. With respect to affect, our results showed that justice-performance relationships were mediated by positive and negative affect, with the relevant affect dimension varying across justice and performance variables. Our discussion of these findings focuses on the merit in integrating the social exchange and affect lenses in future research.
Adaptive beam shaping by controlled thermal lensing in optical elements
NASA Astrophysics Data System (ADS)
Arain, Muzammil A.; Quetschke, Volker; Gleason, Joseph; Williams, Luke F.; Rakhmanov, Malik; Lee, Jinho; Cruz, Rachel J.; Mueller, Guido; Tanner, D. B.; Reitze, David. H.
2007-04-01
We describe an adaptive optical system for use as a tunable focusing element. The system provides adaptive beam shaping via controlled thermal lensing in the optical elements. The system is agile, remotely controllable, touch free, and vacuum compatible; it offers a wide dynamic range, aberration-free focal length tuning, and can provide both positive and negative lensing effects. Focusing is obtained through dynamic heating of an optical element by an external pump beam. The system is especially suitable for use in interferometric gravitational wave interferometers employing high laser power, allowing for in situ control of the laser modal properties and compensation for thermal lensing of the primary laser. Using CO2 laser heating of fused-silica substrates, we demonstrate a focal length variable from infinity to 4.0 m, with a slope of 0.082 diopter/W of absorbed heat. For on-axis operation, no higher-order modes are introduced by the adaptive optical element. Theoretical modeling of the induced optical path change and predicted thermal lens agrees well with measurement.
Adaptive beam shaping by controlled thermal lensing in optical elements.
Arain, Muzammil A; Quetschke, Volker; Gleason, Joseph; Williams, Luke F; Rakhmanov, Malik; Lee, Jinho; Cruz, Rachel J; Mueller, Guido; Tanner, D B; Reitze, David H
2007-04-20
We describe an adaptive optical system for use as a tunable focusing element. The system provides adaptive beam shaping via controlled thermal lensing in the optical elements. The system is agile, remotely controllable, touch free, and vacuum compatible; it offers a wide dynamic range, aberration-free focal length tuning, and can provide both positive and negative lensing effects. Focusing is obtained through dynamic heating of an optical element by an external pump beam. The system is especially suitable for use in interferometric gravitational wave interferometers employing high laser power, allowing for in situ control of the laser modal properties and compensation for thermal lensing of the primary laser. Using CO(2) laser heating of fused-silica substrates, we demonstrate a focal length variable from infinity to 4.0 m, with a slope of 0.082 diopter/W of absorbed heat. For on-axis operation, no higher-order modes are introduced by the adaptive optical element. Theoretical modeling of the induced optical path change and predicted thermal lens agrees well with measurement.
Optically reconfigurable metasurfaces and photonic devices based on phase change materials
NASA Astrophysics Data System (ADS)
Wang, Qian; Rogers, Edward T. F.; Gholipour, Behrad; Wang, Chih-Ming; Yuan, Guanghui; Teng, Jinghua; Zheludev, Nikolay I.
2016-01-01
Photonic components with adjustable parameters, such as variable-focal-length lenses or spectral filters, which can change functionality upon optical stimulation, could offer numerous useful applications. Tuning of such components is conventionally achieved by either micro- or nanomechanical actuation of their constituent parts, by stretching or by heating. Here, we report a novel approach for making reconfigurable optical components that are created with light in a non-volatile and reversible fashion. Such components are written, erased and rewritten as two-dimensional binary or greyscale patterns into a nanoscale film of phase-change material by inducing a refractive-index-changing phase transition with tailored trains of femtosecond pulses. We combine germanium-antimony-tellurium-based films with a diffraction-limited resolution optical writing process to demonstrate a variety of devices: visible-range reconfigurable bichromatic and multi-focus Fresnel zone plates, a super-oscillatory lens with subwavelength focus, a greyscale hologram, and a dielectric metamaterial with on-demand reflection and transmission resonances.
Device for imaging scenes with very large ranges of intensity
Deason, Vance Albert [Idaho Falls, ID
2011-11-15
A device for imaging scenes with a very large range of intensity having a pair of polarizers, a primary lens, an attenuating mask, and an imaging device optically connected along an optical axis. Preferably, a secondary lens, positioned between the attenuating mask and the imaging device is used to focus light on the imaging device. The angle between the first polarization direction and the second polarization direction is adjustable.
Applications of rigid and flexible GRIN-endoscopes
NASA Astrophysics Data System (ADS)
Schenkl, Selma; Ehlers, Alexander; Riemann, Iris; Messerschmidt, Bernhard; Bückle, Rainer; König, Karsten
2007-02-01
Multiphoton autofluorescence imaging became an important technique for minimal invasive examination of cells in biological tissue. Rigid and flexible endoscopes based on gradient index lenses (GRIN-lenses) extend this minimalinvasive technique to deep lying cell layers, inner body and specimens, difficult to access. In the rigid endoscope, a GRIN-lens overcomes the limited depth range, given by the working distance of the microscope objective. The focus of the conventional laser scanning tomography is reproduced tens of millimeters in the specimen under study by the GRIN-lens (diameter 1.8 and 3 μm). We will present images of fluorescent beads, proteins cells and skin tissue, as well as first in vivo measurements on human skin. The autofluorescence signal stems from the endogenous fluorophore elastin and SHG from collagen. The flexible endoscope dispenses completely the need of a microscope next to the specimen of interest. The excitation laser pulses is delivered via a well-characterized photonic crystal fiber and subsequently focused by a newly designed GRIN-lens system. The fluorescence, also transferred by a fiber is detected by a PMT detector. We will show the excellent imaging qualities of a newly developed GRIN-lens system with high-resolution images of proteins, cells and plant tissue and give an out-look on multiphoton endoscopy.
Finesse of transparent tissue cutting by ultrafast lasers at various wavelengths.
Wang, Jenny; Schuele, Georg; Palanker, Daniel
2015-01-01
Transparent ocular tissues, such as the cornea and crystalline lens, can be ablated or dissected using short-pulse lasers. In refractive and cataract surgeries, the cornea, lens, and lens capsule can be cut by producing dielectric breakdown in the focus of a near-infrared (IR) femtosecond laser, which results in explosive vaporization of the interstitial water, causing mechanical rupture of the surrounding tissue. Here, we compare the texture of edges of lens capsule cut by femtosecond lasers with IR and ultraviolet (UV) wavelengths and explore differences in interactions of these lasers with biological molecules. Scanning electron microscopy indicates that a 400-nm laser is capable of producing very smooth cut edges compared to 800 or 1030 nm at a similar focusing angle. Using gel electrophoresis and liquid chromatography/mass spectrometry, we observe laser-induced nonlinear breakdown of proteins and polypeptides by 400-nm femtosecond pulses above and below the dielectric breakdown threshold. On the other hand, 800-nm femtosecond lasers do not produce significant dissociation even above the threshold of dielectric breakdown. However, despite this additional interaction of UV femtosecond laser with proteins, we determine that efficient cutting requires plasma-mediated bubble formation and that remarkably smooth edges are the result of reduced thresholds and smaller focal volume.
The association of contact lens solution use and Acanthamoeba keratitis
Joslin, Charlotte E.; Tu, Elmer Y.; Shoff, Megan E.; Booton, Gregory C.; Fuerst, Paul A.; McMahon, Timothy T.; Anderson, Robert J.; Dworkin, Mark S.; Sugar, Joel; Davis, Faith G.; Stayner, Leslie T.
2009-01-01
Purpose Diagnosis of Acanthamoeba keratitis, a rare but serious corneal infection, has recently increased significantly at the University of Illinois at Chicago (UIC) Cornea Service. The purpose is to investigate Acanthamoeba keratitis risk factors. Design Retrospective case-control study. Methods Setting University, tertiary care hospital. Patients Fifty-five Acanthamoeba keratitis cases with contact lens use were diagnosed between May 1, 2003 and September 15, 2006. Clinic-matched controls with contact lens use were recruited. Subjects completed surveys targeting lens hygiene, contact lens solution use, and water exposure. Main Outcome Measure Acanthamoeba keratitis. Results Thirty-nine (73.6%) cases and 113 (65.3%) controls participated; 38 cases had complete contact lens data. Thirty-five of 38 cases (92.1%) and 47 of 100 controls (47.0%) used soft lenses. Analysis was performed on 30 cases and 39 controls with matched pairs with soft lens use. Exclusive use of AMO Complete MoisturePlus Multi-Purpose Solution was independently associated with Acanthamoeba keratitis in multivariable analysis (55.2% vs. 10.5%; OR, 16.67; 95% CI, 2.11–162.63; p = 0.008). However, 38.8% of cases reported no use of AMO Complete MoisturePlus Multi-Purpose Solution or used it in combination with other solutions. Although not statistically significant, additional hygiene-related variables (solution ‘reuse’, lack of ‘rubbing’, and showering with lenses) suggest a pattern of risk,. Conclusions AMO Complete MoisturePlus Multi-Purpose Solution use is independently associated with Acanthamoeba keratitis among soft contact lens users. However, it does not explain all cases, suggesting additional factors. Further research into environmental risk factors and hygiene practices is warranted, especially considering this is the second outbreak of an atypical, contact lens-related infection. PMID:17588524
The association of contact lens solution use and Acanthamoeba keratitis.
Joslin, Charlotte E; Tu, Elmer Y; Shoff, Megan E; Booton, Gregory C; Fuerst, Paul A; McMahon, Timothy T; Anderson, Robert J; Dworkin, Mark S; Sugar, Joel; Davis, Faith G; Stayner, Leslie T
2007-08-01
To investigate Acanthamoeba keratitis (AK) risk factors. Diagnosis of AK, a rare but serious corneal infection, has recently increased significantly at the University of Illinois at Chicago (UIC) Cornea Service. Retrospective case-control study. settings: University, tertiary care hospital. patients: Fifty-five AK cases with contact lens use were diagnosed between May 1, 2003 and September 15, 2006. Clinic-matched controls with contact lens use were recruited. Subjects completed surveys targeting lens hygiene, contact lens solution use, and water exposure. main outcome measure: Acanthamoeba keratitis. Thirty-nine (73.6%) cases and 113 (65.3%) controls participated; 38 cases had complete contact lens data. Thirty-five of 38 cases (92.1%) and 47 of 100 controls (47.0%) used soft lenses. Analysis was performed on 30 cases and 39 controls with matched pairs with soft lens use. Exclusive use of Advance Medical Optics (AMO) Complete MoisturePlus Multi-Purpose Solution was independently associated with AK in multivariable analysis (55.2% vs 10.5%; odds ratio [OR], 16.67; 95% confidence interval [CI] 2.11 to 162.63; P = .008). However, 38.8% of cases reported no use of AMO Complete MoisturePlus Multi-Purpose Solution either alone or in combination with other solutions. Although not statistically significant, additional hygiene-related variables (solution "reuse," lack of "rubbing," and showering with lenses) suggest a pattern of risk. AMO Complete MoisturePlus Multi-Purpose Solution use is independently associated with AK among soft contact lens users. However, it does not explain all cases, suggesting additional factors. Further research into environmental risk factors and hygiene practices is warranted, especially considering this is the second outbreak of an atypical, contact lens-related infection.
NASA Astrophysics Data System (ADS)
Goosman, David R.; Avara, George R.; Perry, Stephen J.
2001-04-01
We have in the past used several types of optical probe lenses for delivering and collecting laser light to an experiment for laser velocimetry. When the test surface was in focus, however, the collected light would fill mostly the laser fiber rather than the collection fiber(s). We have designed, developed and used for 8 years nested-lens probe assemblies that solve this problem. Our first version used a commercial AR-coated glass achromat, which we cored to remove the inner fourth of its area. The core was then reinserted with its optical center offset from that of annulus by an amount slightly less than the separation between the laser and collector fibers. The laser and collector fibers are placed in contact with each other behind the lens and have NA values of 0.11 and 0.22, respectively. Because most of the collected light now focused on the collection fiber, this system was far superior to the single lens systems, but was laborious. For the last five years we used injection-molded acrylic aspheric nested lenses, which are inexpensive in quantity and require little labor to install into a probe. Only an azimuthal rotation and positioning of the fiber plane are needed to incorporate the plastic lens into a probe. Special ray-trace codes were written and used to design the lens, and many iterations by the molder were required to develop the injection processing parameters to produce a good lens, since it was thick for its diameter. These probes have real light collection efficiencies of 75% of theoretical, work well over a wide range of distances, with collection depths of field matching theory. The lenses can take 100 watts of pulsed power many times without damage, since the lens is designed so that reflections from the lens surface do not focus within the lens. The collection fiber size is designed to work with our manybeam velocimeter facility reported in a previous Congress, where the collection NA times collection fiber size exceeds the acceptance of the velocimeter. The Doppler-shifted light enters the collection fiber with angles between 0.11 and 0.2, with little light in the 0 to 0.11 NA region. However, the manybeam velocimeter uses just the light in the 0 to 0.11 NA range, except when we link two analyzer tables together. A slight amount of mode scrambling of the Doppler shifted light converts the light into a uniformly filled NA equals 0.2 angular range before entering the velocimeter analyzer table. We have expended seven hundred plastic nested lenses in various experiments. The most recent version of the fiber cable assembly will be shown. Six situations will be discussed where multiple reflected frequencies were observed in experiments, illustrating an advantage of the Fabry-Perot vs. the VISAR method.
Curiosity's Mars Hand Lens Imager (MAHLI) Investigation
Edgett, Kenneth S.; Yingst, R. Aileen; Ravine, Michael A.; Caplinger, Michael A.; Maki, Justin N.; Ghaemi, F. Tony; Schaffner, Jacob A.; Bell, James F.; Edwards, Laurence J.; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sullivan, Robert J.; Sumner, Dawn Y.; Thomas, Peter C.; Jensen, Elsa H.; Simmonds, John J.; Sengstacken, Aaron J.; Wilson, Reg G.; Goetz, Walter
2012-01-01
The Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) investigation will use a 2-megapixel color camera with a focusable macro lens aboard the rover, Curiosity, to investigate the stratigraphy and grain-scale texture, structure, mineralogy, and morphology of geologic materials in northwestern Gale crater. Of particular interest is the stratigraphic record of a ?5 km thick layered rock sequence exposed on the slopes of Aeolis Mons (also known as Mount Sharp). The instrument consists of three parts, a camera head mounted on the turret at the end of a robotic arm, an electronics and data storage assembly located inside the rover body, and a calibration target mounted on the robotic arm shoulder azimuth actuator housing. MAHLI can acquire in-focus images at working distances from ?2.1 cm to infinity. At the minimum working distance, image pixel scale is ?14 μm per pixel and very coarse silt grains can be resolved. At the working distance of the Mars Exploration Rover Microscopic Imager cameras aboard Spirit and Opportunity, MAHLI?s resolution is comparable at ?30 μm per pixel. Onboard capabilities include autofocus, auto-exposure, sub-framing, video imaging, Bayer pattern color interpolation, lossy and lossless compression, focus merging of up to 8 focus stack images, white light and longwave ultraviolet (365 nm) illumination of nearby subjects, and 8 gigabytes of non-volatile memory data storage.
Factors influencing bacterial adhesion to contact lenses.
Dutta, Debarun; Cole, Nerida; Willcox, Mark
2012-01-01
The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria.
Addressing challenges of modulation transfer function measurement with fisheye lens cameras
NASA Astrophysics Data System (ADS)
Deegan, Brian M.; Denny, Patrick E.; Zlokolica, Vladimir; Dever, Barry; Russell, Laura
2015-03-01
Modulation transfer function (MTF) is a well defined and accepted method of measuring image sharpness. The slanted edge test, as defined in ISO12233 is a standard method of calculating MTF, and is widely used for lens alignment and auto-focus algorithm verification. However, there are a number of challenges which should be considered when measuring MTF in cameras with fisheye lenses. Due to trade-offs related Petzval curvature, planarity of the optical plane is difficult to achieve in fisheye lenses. It is therefore critical to have the ability to accurately measure sharpness throughout the entire image, particularly for lens alignment. One challenge for fisheye lenses is that, because of the radial distortion, the slanted edges will have different angles, depending on the location within the image and on the distortion profile of the lens. Previous work in the literature indicates that MTF measurements are robust for angles between 2 and 10 degrees. Outside of this range, MTF measurements become unreliable. Also, the slanted edge itself will be curved by the lens distortion, causing further measurement problems. This study summarises the difficulties in the use of MTF for sharpness measurement in fisheye lens cameras, and proposes mitigations and alternative methods.
Factors influencing bacterial adhesion to contact lenses
Dutta, Debarun; Willcox, Mark
2012-01-01
The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria. PMID:22259220
Optimal power distribution for minimizing pupil walk in a 7.5X afocal zoom lens
NASA Astrophysics Data System (ADS)
Song, Wanyue; Zhao, Yang; Berman, Rebecca; Bodell, S. Yvonne; Fennig, Eryn; Ni, Yunhui; Papa, Jonathan C.; Yang, Tianyi; Yee, Anthony J.; Moore, Duncan T.; Bentley, Julie L.
2017-11-01
An extensive design study was conducted to find the best optimal power distribution and stop location for a 7.5x afocal zoom lens that controls the pupil walk and pupil location through zoom. This afocal zoom lens is one of the three components in a VIS-SWIR high-resolution microscope for inspection of photonic chips. The microscope consists of an afocal zoom, a nine-element objective and a tube lens and has diffraction limited performance with zero vignetting. In this case, the required change in object (sample) size and resolution is achieved by the magnification change of the afocal component. This creates strict requirements for both the entrance and exit pupil locations of the afocal zoom to couple the two sides successfully. The first phase of the design study looked at conventional four group zoom lenses with positive groups in the front and back and the stop at a fixed location outside the lens but resulted in significant pupil walk. The second phase of the design study focused on several promising unconventional four-group power distribution designs with moving stops that minimized pupil walk and had an acceptable pupil location (as determined by the objective and tube lens).
Athermal design and analysis of glass-plastic hybrid lens
NASA Astrophysics Data System (ADS)
Yang, Jian; Cen, Zhaofeng; Li, Xiaotong
2018-01-01
With the rapid development of security market, the glass-plastic hybrid lens has gradually become a choice for the special requirements like high imaging quality in a wide temperature range and low cost. The reduction of spherical aberration is achieved by using aspherical surface instead of increasing the number of lenses. Obviously, plastic aspherical lens plays a great role in the cost reduction. However, the hybrid lens has a priority issue, which is the large thermal coefficient of expansion of plastic, causing focus shift and seriously affecting the imaging quality, so the hybrid lens is highly sensitive to the change of temperature. To ensure the system operates normally in a wide temperature range, it is necessary to eliminate the influence of temperature on the hybrid lens system. A practical design method named the Athermal Material Map is summarized and verified by an athermal design example according to the design index. It includes the distribution of optical power and selection of glass or plastic. The design result shows that the optical system has excellent imaging quality at a wide temperature range from -20 ° to 70 °. The method of athermal design in this paper has generality which could apply to optical system with plastic aspherical surface.
A Novel Terminal Web-Like Structure in Cortical Lens Fibers: Architecture and Functional Assessment
Al-Ghoul, Kristin J.; Lindquist, Timothy P.; Kirk, Spencer S.; Donohue, Sean T.
2010-01-01
This study describes a novel cytoskeletal array in fiber cells of the ocular lens of the rat and shows its relationship to the classical terminal web of other epithelial tissues. Naive adult Sprague-Dawley rats (n=28) were utilized. F-actin, fodrin, myosin IIA and CP49 distribution was assessed in anterior and posterior polar sections. For functional analysis, lenses were cultured with or without cytochalasin-D for 3 hours, then processed for confocal microscopy or assessed by laser scan analysis along sutures. Phalloidin labeling demonstrated a dense mesh of F-actin adjacent to posterior sutural domains to a subcapsular depth of 400 μm. Anterior polar sections revealed a comparable actin structure adjacent to anterior suture branches however, it was not developed in superficial fibers. Fodrin and myosin were localized within the web-like actin apparatus. The data was used to construct a model showing that the cytoskeletal array is located within the blunt, variable-width fiber ends that abut at sutures such that the ‘terminal web’ flanks the suture on either side. Treatment with cytochalasin-D resulted in partial disassembly of the ‘terminal web’ and perturbed cellular organization. Laser scan analysis revealed that cytochalasin-D treated lenses had significantly greater focal variability than control lenses (p=0.020). We conclude that cortical fibers of rat lenses contain a bipolar structure that is structurally and compositionally analogous to classical terminal webs. The results indicate that the lens ‘terminal web’ functions to stabilize lens fiber ends at sutures thus minimizing structural disorder, which in turn, promotes the establishment and maintenance of lens transparency. PMID:20730867
Sorbara, Luigina; Maram, Jyotsna; Simpson, Trefford; Hutchings, Natalie
2018-04-01
First, to examine how wearing high and low modulus lenses with two different base curves affected lens fit, and the corneal tissue and bulbar conjunctival vascular tissue (bulbar redness and blood velocity). Secondly, to quantify the associations between these baseline and outcome variables and the third purpose was to correlate these variables with end of day comfort. Thirty participants wore higher (PureVision (PV) 8.3, 8.6) and lower (Acuvue Advance (AA) 8.3, 8.7) modulus silicone hydrogel lenses for two weeks on a daily wear basis. Lens fitting characteristics were examined. Corneal epithelial thickness was measured and the cornea and conjunctiva were assessed. RBC velocity was estimated from high magnification bulbar conjunctival images. Subjective comfort/dryness was reported by participants using visual analogue scales. AA lenses were rated the most comfortable (ANOVA, p=0.041). The least movement was while using the AA 8.3 base curve lens (Tukey p=0.028). Steep AA and PV lenses showed significantly higher conjunctival staining at the 2 week visit (ANOVA, p=0.029). There was a significant decrease in RBC velocity with both steeper AA lenses vs PV lenses (Tukey, p=0.001). Comparing baseline and 2 week visits, there was a significant negative correlation for the PV 8.3 between comfort and superior bulbar staining (r=-0.53). For both the PV 8.3 and AA 8.3 reduced RBC velocity was correlated with dryness (r=0.61 and r=0.91, respectively). Physical differences in contact lenses affect structural and vascular functional aspects of the ocular surface and these may be associated with symptoms of dryness. Copyright © 2017 British Contact Lens Association. All rights reserved.
Gabor domain optical coherence microscopy
NASA Astrophysics Data System (ADS)
Murali, Supraja
Time domain Optical Coherence Tomography (TD-OCT), first reported in 1991, makes use of the low temporal coherence properties of a NIR broadband laser to create depth sectioning of up to 2mm under the surface using optical interferometry and point to point scanning. Prior and ongoing work in OCT in the research community has concentrated on improving axial resolution through the development of broadband sources and speed of image acquisition through new techniques such as Spectral domain OCT (SD-OCT). In SD-OCT, an entire depth scan is acquired at once with a low numerical aperture (NA) objective lens focused at a fixed point within the sample. In this imaging geometry, a longer depth of focus is achieved at the expense of lateral resolution, which is typically limited to 10 to 20 mum. Optical Coherence Microscopy (OCM), introduced in 1994, combined the advantages of high axial resolution obtained in OCT with high lateral resolution obtained by increasing the NA of the microscope placed in the sample arm. However, OCM presented trade-offs caused by the inverse quadratic relationship between the NA and the DOF of the optics used. For applications requiring high lateral resolution, such as cancer diagnostics, several solutions have been proposed including the periodic manual re-focusing of the objective lens in the time domain as well as the spectral domain C-mode configuration in order to overcome the loss in lateral resolution outside the DOF. In this research, we report for the first time, high speed, sub-cellular imaging (lateral resolution of 2 mum) in OCM using a Gabor domain image processing algorithm with a custom designed and fabricated dynamic focus microscope interfaced to a Ti:Sa femtosecond laser centered at 800 nm within an SD-OCM configuration. It is envisioned that this technology will provide a non-invasive replacement for the current practice of multiple biopsies for skin cancer diagnosis. The research reported here presents three important advances to this technology all of which have been demonstrated in full functional hardware conceived and built during the course of this research. First, it has been demonstrated that the coherence gate created by the femtosecond laser can be coupled into a scanning optical microscope using optical design methods to include liquid lens technology that enables scanning below the surface of skin with no moving parts and at high resolution throughout a 2x2x2 mm imaging cube. Second, the integration the variable-focus liquid lens technology within a fixed-optics microscope custom optical design helped increase the working NA by an order of magnitude over the limitation imposed by the liquid lens alone. Thus, this design has enabled homogenous axial and lateral resolution at the micron-level (i.e., 2 mum) while imaging in the spectral domain, and still maintaining in vivo speeds. The latest images in biological specimens clearly demonstrate sub-cellular resolution in all dimensions throughout the imaging volume. Third, this new modality for data collection has been integrated with an automated Gabor domain image registration and fusion algorithm to provide full resolution images across the data cube in real-time. We refer to this overall OCM method as Gabor domain OCM (GD-OCM). These advantages place GD-OCM in a unique position with respect to the diagnosis of cancer, because when fully developed, it promises to enable fast and accurate screening for early symptoms that could lead to prevention. The next step for this technology is to apply it directly, in a clinical environment. This step is underway and is expected to be reported by the next generation of researchers within this group.
Dual FOV infrared lens design with the laser common aperture optics
NASA Astrophysics Data System (ADS)
Chang, Wei-jun; Zhang, Xuan-zhi; Luan, Ya-dong; Zhang, Bo
2015-02-01
With the demand of autonomous precision guidance of air defense missile, the system scheme of the IR imaging/Ladar dual-mode seeker with a common aperture was proposed, and the optical system used in was designed. The system had a common receiving aperture, and its structure was very compact, so it could meet the requirement for the miniaturization of the seeker. Besides, it also could meet the demands of a wide field of view for searching target, and the demands for accurately recognizing and tracking the target at the same time. In order to increase the narrow FOV tracking performance, the dual FOV infrared optical used the zooming mode which some components flip in or out the optical system to firm the target signal. The dual FOV optics are divided into the zooming part, with dual variable focal length, and the reimaging part which was chosen in such a way to minimize the objective lens while maintaining 100% cold shield efficiency. The final infrared optics including 4°×3°(NFOV) and 16°×12°(WFOV) was designed. The NFOV lens composed of two common IR/Ladar lens, three relay lens, a beam splitter and two reflective fold mirrors, while WFOV lens increased two lens such as Germanium and Silicon. The common IR/Ladar lens ZnS and ZnSe could refractive the IR optics and Laser optics. The beam splitter which refractived IR optics and reflected Laser optics was located in the middle of Germanium and Silicon. The designed optical system had good image quality, and fulfilled the performance requirement of seeker system.
Improved alternating gradient transport and focusing of neutral molecules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalnins, Juris; Lambertson, Glen; Gould, Harvey
2001-12-02
Polar molecules, in strong-field seeking states, can be transported and focused by an alternating sequence of electric field gradients that focus in one transverse direction while defocusing in the other. We show by calculation and numerical simulation, how one may greatly improve the alternating gradient transport and focusing of molecules. We use a new optimized multipole lens design, a FODO lattice beam transport line, and lenses to match the beam transport line to the beam source and the final focus. We derive analytic expressions for the potentials, fields, and gradients that may be used to design these lenses. We describemore » a simple lens optimization procedure and derive the equations of motion for tracking molecules through a beam transport line. As an example, we model a straight beamline that transports a 560 m/s jet-source beam of methyl fluoride molecules 15 m from its source and focuses it to 2 mm diameter. We calculate the beam transport line acceptance and transmission, for a beam with velocity spread, and estimate the transmitted intensity for specified source conditions. Possible applications are discussed.« less
NASA Astrophysics Data System (ADS)
Kremer, Matthias P.; Tortschanoff, Andreas
2014-03-01
One key challenge in the field of microfluidics and lab-on-a-chip experiments for biological or chemical applications is the remote manipulation of fluids, droplets and particles. These can be volume elements of reactants, particles coated with markers, cells or many others. Light-driven microfluidics is one way of accomplishing this challenge. In our work, we manipulated micrometre sized polystyrene beads in a microfluidic environment by inducing thermal flows. Therefore, the beads were held statically in an unstructured microfluidic chamber, containing a dyed watery solution. Inside this chamber, the beads were moved along arbitrary trajectories on a micrometre scale. The experiments were performed, using a MOEMS (micro-opto-electro-mechanical-systems)-based laser scanner with a variable focal length. This scanner system is integrated in a compact device, which is flexibly applicable to various microscope setups. The device utilizes a novel approach for varying the focal length, using an electrically tunable lens. A quasi statically driven MOEMS mirror is used for beam steering. The combination of a tunable lens and a dual axis micromirror makes the device very compact and robust and is capable of positioning the laser focus at any arbitrary location within a three dimensional working space. Hence, the developed device constitutes a valuable extension to manually executed microfluidic lab-on-chip experiments.
Milton, H E; Nagaraj, M; Kaur, S; Jones, J C; Morgan, P B; Gleeson, H F
2014-11-01
Liquid crystal lenses are an emerging technology that can provide variable focal power in response to applied voltage. Many designs for liquid-crystal-based lenses are polarization dependent, so that 50% of light is not focused as required, making polarization-independent technologies very attractive. Recently, the dark conglomerate (DC) phase, which is an optically isotropic liquid crystalline state, has been shown to exhibit a large change in refractive index in response to an applied electric field (Δn=0.04). This paper describes computational modeling of the electrostatic solutions for two different types of 100 μm diameter liquid crystal lenses, which include the DC phase, demonstrating that it shows great potential for efficient isotropic optical switching in lenses. A feature of the field dependence of the refractive index change in the DC phase is that it is approximately linear in a certain range, leading to the prediction of excellent optical quality for driving fields in this regime. Interestingly, a simulated microlens is shown to exhibit two modes of operation: a positive lens based upon a uniform bulk change in refractive index at high voltages, and a negative lens resulting from the induction of a gradient index effect at intermediate voltages.
Creating and Steering Highly Directional Electron Beams in Graphene.
Liu, Ming-Hao; Gorini, Cosimo; Richter, Klaus
2017-02-10
We put forward a concept to create highly collimated, nondispersive electron beams in pseudorelativistic Dirac materials such as graphene or topological insulator surfaces. Combining negative refraction and Klein collimation at a parabolic pn junction, the proposed lens generates beams, as narrow as the focal length, that stay focused over scales of several microns and can be steered by a magnetic field without losing collimation. We demonstrate the lens capabilities by applying it to two paradigmatic settings of graphene electron optics: We propose a setup for observing high-resolution angle-dependent Klein tunneling, and, exploiting the intimate quantum-to-classical correspondence of these focused electron waves, we consider high-fidelity transverse magnetic focusing accompanied by simulations for current mapping through scanning gate microscopy. Our proposal opens up new perspectives for next-generation graphene electron optics experiments.