Sample records for variable joint stiffness

  1. Improving stability and curving passing performance for railway vehicles with a variable stiffness MRF rubber joint

    NASA Astrophysics Data System (ADS)

    Harris, B. J.; Sun, S. S.; Li, W. H.

    2017-03-01

    With the growing need for effective intercity transport, the need for more advanced rail vehicle technology has never been greater. The conflicting primary longitudinal suspension requirements of high speed stability and curving performance limit the development of rail vehicle technology. This paper presents a novel magnetorheological fluid based joint with variable stiffness characteristics for the purpose of overcoming this parameter conflict. Firstly, the joint design and working principle is developed. Following this, a prototype is tested by MTS to characterize its variable stiffness properties under a range of conditions. Lastly, the performance of the proposed MRF rubber joint with regard to improving train stability and curving performance is numerically evaluated.

  2. Lower limb joint kinetics and ankle joint stiffness in the sprint start push-off.

    PubMed

    Charalambous, Laura; Irwin, Gareth; Bezodis, Ian N; Kerwin, David

    2012-01-01

    Sprint push-off technique is fundamental to sprint performance and joint stiffness has been identified as a performance-related variable during dynamic movements. However, joint stiffness for the push-off and its relationship with performance (times and velocities) has not been reported. The aim of this study was to quantify and explain lower limb net joint moments and mechanical powers, and ankle stiffness during the first stance phase of the push-off. One elite sprinter performed 10 maximal sprint starts. An automatic motion analysis system (CODA, 200 Hz) with synchronized force plates (Kistler, 1000 Hz) collected kinematic profiles at the hip, knee, and ankle and ground reaction forces, providing input for inverse dynamics analyses. The lower-limb joints predominately extended and revealed a proximal-to-distal sequential pattern of maximal extensor angular velocity and positive power production. Pearson correlations revealed relationships (P < 0.05) between ankle stiffness (5.93 ± 0.75 N x m x deg(-1)) and selected performance variables. Relationships between negative power phase ankle stiffness and horizontal (r = -0.79) and vertical (r = 0.74) centre of mass velocities were opposite in direction to the positive power phase ankle stiffness (horizontal: r = 0.85; vertical: r = -0.54). Thus ankle stiffness may affect the goals of the sprint push-off in different ways, depending on the phase of stance considered.

  3. A torsional MRE joint for a C-shaped robotic leg

    NASA Astrophysics Data System (ADS)

    Christie, M. D.; Sun, S. S.; Ning, D. H.; Du, H.; Zhang, S. W.; Li, W. H.

    2017-01-01

    Serving to improve stability and energy efficiency during locomotion, in nature, animals modulate their leg stiffness to adapt to their terrain. Now incorporated into many locomotive robot designs, such compliance control can enable disturbance rejection and improved transition between changing ground conditions. This paper presents a novel design of a variable stiffness leg utilizing a magnetorheological elastomer joint in a literal rolling spring loaded inverted pendulum (R-SLIP) morphology. Through the semi-active control of this hybrid permanent-magnet and coil design, variable stiffness is realized, offering a design which is capable of both softening and stiffening in an adaptive sort of way, with a maximum stiffness change of 48.0%. Experimental characterization first serves to assess the stiffness variation capacity of the torsional joint, and through later comparison with force testing of the leg, the linear stiffness is characterized with the R-SLIP-like behavior of the leg being demonstrated. Through the force relationships applied, a generalized relationship for determining linear stiffness based on joint rotation angle is also proposed, further aiding experimental validation.

  4. Influence of running velocity on vertical, leg and joint stiffness : modelling and recommendations for future research.

    PubMed

    Brughelli, Matt; Cronin, John

    2008-01-01

    Human running can be modelled as either a spring-mass model or multiple springs in series. A force is required to stretch or compress the spring, and thus stiffness, the variable of interest in this paper, can be calculated from the ratio of this force to the change in spring length. Given the link between force and length change, muscle stiffness and mechanical stiffness have been areas of interest to researchers, clinicians, and strength and conditioning practitioners for many years. This review focuses on mechanical stiffness, and in particular, vertical, leg and joint stiffness, since these are the only stiffness types that have been directly calculated during human running. It has been established that as running velocity increases from slow-to-moderate values, leg stiffness remains constant while both vertical stiffness and joint stiffness increase. However, no studies have calculated vertical, leg or joint stiffness over a range of slow-to-moderate values to maximum values in an athletic population. Therefore, the effects of faster running velocities on stiffness are relatively unexplored. Furthermore, no experimental research has examined the effects of training on vertical, leg or joint stiffness and the subsequent effects on running performance. Various methods of training (Olympic style weightlifting, heavy resistance training, plyometrics, eccentric strength training) have shown to be effective at improving running performance. However, the effects of these training methods on vertical, leg and joint stiffness are unknown. As a result, the true importance of stiffness to running performance remains unexplored, and the best practice for changing stiffness to optimize running performance is speculative at best. It is our hope that a better understanding of stiffness, and the influence of running speed on stiffness, will lead to greater interest and an increase in experimental research in this area.

  5. Parameter identification and optimization of slide guide joint of CNC machine tools

    NASA Astrophysics Data System (ADS)

    Zhou, S.; Sun, B. B.

    2017-11-01

    The joint surface has an important influence on the performance of CNC machine tools. In order to identify the dynamic parameters of slide guide joint, the parametric finite element model of the joint is established and optimum design method is used based on the finite element simulation and modal test. Then the mode that has the most influence on the dynamics of slip joint is found through harmonic response analysis. Take the frequency of this mode as objective, the sensitivity analysis of the stiffness of each joint surface is carried out using Latin Hypercube Sampling and Monte Carlo Simulation. The result shows that the vertical stiffness of slip joint surface constituted by the bed and the slide plate has the most obvious influence on the structure. Therefore, this stiffness is taken as the optimization variable and the optimal value is obtained through studying the relationship between structural dynamic performance and stiffness. Take the stiffness values before and after optimization into the FEM of machine tool, and it is found that the dynamic performance of the machine tool is improved.

  6. Estimation of Quasi-Stiffness of the Human Knee in the Stance Phase of Walking

    PubMed Central

    Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.

    2013-01-01

    Biomechanical data characterizing the quasi-stiffness of lower-limb joints during human locomotion is limited. Understanding joint stiffness is critical for evaluating gait function and designing devices such as prostheses and orthoses intended to emulate biological properties of human legs. The knee joint moment-angle relationship is approximately linear in the flexion and extension stages of stance, exhibiting nearly constant stiffnesses, known as the quasi-stiffnesses of each stage. Using a generalized inverse dynamics analysis approach, we identify the key independent variables needed to predict knee quasi-stiffness during walking, including gait speed, knee excursion, and subject height and weight. Then, based on the identified key variables, we used experimental walking data for 136 conditions (speeds of 0.75–2.63 m/s) across 14 subjects to obtain best fit linear regressions for a set of general models, which were further simplified for the optimal gait speed. We found R2 > 86% for the most general models of knee quasi-stiffnesses for the flexion and extension stages of stance. With only subject height and weight, we could predict knee quasi-stiffness for preferred walking speed with average error of 9% with only one outlier. These results provide a useful framework and foundation for selecting subject-specific stiffness for prosthetic and exoskeletal devices designed to emulate biological knee function during walking. PMID:23533662

  7. Shoe midsole longitudinal bending stiffness and running economy, joint energy, and EMG.

    PubMed

    Roy, Jean-Pierre R; Stefanyshyn, Darren J

    2006-03-01

    It has been shown that mechanical energy is dissipated at the metatarsophalangeal (MTP) joint during running and jumping. Furthermore, increasing the longitudinal bending stiffness of the midsole significantly reduced the energy dissipated at the MTP joint and increased jump performance. It was hypothesized that increasing midsole longitudinal bending stiffness would also lead to improvements in running economy. This study investigated the influence of midsole longitudinal bending stiffness on running economy (performance variable) and evaluated the local effects on joint energetics and muscular activity. Carbon fiber plates were inserted into running shoe midsoles and running economy, joint energy, and electromyographic (EMG) data were collected on 13 subjects. Approximately a 1% metabolic energy savings was observed when subjects ran in a stiff midsole relative to the control midsole. Subjects with a greater body mass had a greater decrease in oxygen consumption rates in the stiff midsole relative to the control midsole condition. The stiffer midsoles showed no significant differences in energy absorption at the MTP joint compared with the control shoe. Finally, no significant changes were observed in muscular activation. Increasing midsole longitudinal bending stiffness led to improvements in running economy, yet the underlying mechanisms that can be attributed to this improvement are still not fully understood.

  8. Changes in In Vivo Knee Loading with a Variable-Stiffness Intervention Shoe Correlate with Changes in the Knee Adduction Moment

    PubMed Central

    Erhart, Jennifer C.; Dyrby, Chris O.; D'Lima, Darryl D.; Colwell, Clifford W.; Andriacchi, Thomas P.

    2010-01-01

    External knee adduction moment can be reduced using footwear interventions, but the exact changes in in vivo medial joint loading remain unknown. An instrumented knee replacement was used to assess changes in in vivo medial joint loading in a single patient walking with a variable-stiffness intervention shoe. We hypothesized that during walking with a load modifying variable-stiffness shoe intervention: (1) the first peak knee adduction moment will be reduced compared to a subject's personal shoes; (2) the first peak in vivo medial contact force will be reduced compared to personal shoes; and (3) the reduction in knee adduction moment will be correlated with the reduction in medial contact force. The instrumentation included a motion capture system, force plate, and the instrumented knee prosthesis. The intervention shoe reduced the first peak knee adduction moment (13.3%, p=0.011) and medial compartment joint contact force (22%; p=0.008) compared to the personal shoe. The change in first peak knee adduction moment was significantly correlated with the change in first peak medial contact force (R2=0.67, p=0.007). Thus, for a single subject with a total knee prosthesis the variable-stiffness shoe reduces loading on the affected compartment of the joint. The reductions in the external knee adduction moment are indicative of reductions in in vivo medial compressive force with this intervention. PMID:20973058

  9. Joint stability characteristics of the ankle complex after lateral ligamentous injury, part I: a laboratory comparison using arthrometric measurement.

    PubMed

    Kovaleski, John E; Heitman, Robert J; Gurchiek, Larry R; Hollis, J M; Liu, Wei; Pearsall, Albert W

    2014-01-01

    The mechanical property of stiffness may be important to investigating how lateral ankle ligament injury affects the behavior of the viscoelastic properties of the ankle complex. A better understanding of injury effects on tissue elastic characteristics in relation to joint laxity could be obtained from cadaveric study. To biomechanically determine the laxity and stiffness characteristics of the cadaver ankle complex before and after simulated injury to the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) during anterior drawer and inversion loading. Cross-sectional study. University research laboratory. Seven fresh-frozen cadaver ankle specimens. All ankles underwent loading before and after simulated lateral ankle injury using an ankle arthrometer. The dependent variables were anterior displacement, anterior end-range stiffness, inversion rotation, and inversion end-range stiffness. Isolated ATFL and combined ATFL and CFL sectioning resulted in increased anterior displacement but not end-range stiffness when compared with the intact ankle. With inversion loading, combined ATFL and CFL sectioning resulted in increased range of motion and decreased end-range stiffness when compared with the intact and ATFL-sectioned ankles. The absence of change in anterior end-range stiffness between the intact and ligament-deficient ankles indicated bony and other soft tissues functioned to maintain stiffness after pathologic joint displacement, whereas inversion loading of the CFL-deficient ankle after pathologic joint displacement indicated the ankle complex was less stiff when supported only by the secondary joint structures.

  10. Running Economy: Neuromuscular and Joint Stiffness Contributions in Trained Runners.

    PubMed

    Tam, Nicholas; Tucker, Ross; Santos-Concejero, Jordan; Prins, Danielle; Lamberts, Robert P

    2018-05-29

    It is debated whether running biomechanics make good predictors of running economy, with little known information about the neuromuscular and joint stiffness contributions to economical running gait. The aim of this study was to understand the relationship between certain neuromuscular and spatiotemporal biomechanical factors associated with running economy. Thirty trained runners performed a 6-minute constant-speed running set at 3.3 m∙s -1 , where oxygen consumption was assessed. Overground running trials were also performed at 3.3 m∙s -1 to assess kinematics, kinetics and muscle activity. Spatiotemporal gait variables, joint stiffness, pre-activation and stance phase muscle activity (gluteus medius; rectus femoris (RF); biceps femoris(BF); peroneus longus (PL); tibialis anterior (TA); gastrocnemius lateralis and medius (LG and MG) were variables of specific interest and thus determined. Additionally, pre-activation and ground contact of agonist:antagonist co-activation were calculated. More economical runners presented with short ground contact times (r=0.639, p<0.001) and greater strides frequencies (r=-0.630, p<0.001). Lower ankle and greater knee stiffness were associated with lower oxygen consumption (r=0.527, p=0.007 & r=0.384, p=0.043, respectively). Only LG:TA co-activation during stance were associated with lower oxygen cost of transport (r=0.672, p<0.0001). Greater muscle pre-activation and bi-articular muscle activity during stance were associated with more economical runners. Consequently, trained runners who exhibit greater neuromuscular activation prior to and during ground contact, in turn optimise spatiotemporal variables and joint stiffness, will be the most economical runners.

  11. Bio-inspired control of joint torque and knee stiffness in a robotic lower limb exoskeleton using a central pattern generator.

    PubMed

    Schrade, Stefan O; Nager, Yannik; Wu, Amy R; Gassert, Roger; Ijspeert, Auke

    2017-07-01

    Robotic lower limb exoskeletons are becoming increasingly popular in therapy and recreational use. However, most exoskeletons are still rather limited in their locomotion speed and the activities of daily live they can perform. Furthermore, they typically do not allow for a dynamic adaptation to the environment, as they are often controlled with predefined reference trajectories. Inspired by human leg stiffness modulation during walking, variable stiffness actuators increase flexibility without the need for more complex controllers. Actuation with adaptable stiffness is inspired by the human leg stiffness modulation during walking. However, this actuation principle also introduces the stiffness setpoint as an additional degree of freedom that needs to be coordinated with the joint trajectories. As a potential solution to this issue a bio-inspired controller based on a central pattern generator (CPG) is presented in this work. It generates coordinated joint torques and knee stiffness modulations to produce flexible and dynamic gait patterns for an exoskeleton with variable knee stiffness actuation. The CPG controller is evaluated and optimized in simulation using a model of the exoskeleton. The CPG controller produced stable and smooth gait for walking speeds from 0.4 m/s up to 1.57 m/s with a torso stabilizing force that simulated the use of crutches, which are commonly needed by exoskeleton users. Through the CPG, the knee stiffness intrinsically adapted to the frequency and phase of the gait, when the speed was changed. Additionally, it adjusted to changes in the environment in the form of uneven terrain by reacting to ground contact forces. This could allow future exoskeletons to be more adaptive to various environments, thus making ambulation more robust.

  12. Bioinspired Robotic Fingers Based on Pneumatic Actuator and 3D Printing of Smart Material.

    PubMed

    Yang, Yang; Chen, Yonghua; Li, Yingtian; Chen, Michael Z Q; Wei, Ying

    2017-06-01

    In this article, we have proposed a novel robotic finger design principle aimed to address two challenges in soft pneumatic grippers-the controllability of the stiffness and the controllability of the bending position. The proposed finger design is composed of a 3D printed multimaterial substrate and a soft pneumatic actuator. The substrate has four polylactic acid (PLA) segments interlocked with three shape memory polymer (SMP) joints, inspired by bones and joints in human fingers. By controlling the thermal energy of an SMP joint, the stiffness of the joints is modulated due to the dramatic change in SMP elastic modulus around its glass transition temperature (T g ). When SMP joints are heated above T g , they exhibit very small stiffness, allowing the finger to easily bend around the SMP joints if the attached soft actuator is actuated. When there is no force from the soft actuator, shape recovery stress in SMP contributes to the finger's shape restoration. Since each joint's rotation can be individually controlled, the position control of the finger is made possible. Experimental analysis has been conducted to show the finger's variable stiffness and the result is compared with the analytical values. It is found that the stiffness ratio can be 24.9 times for a joint at room temperature (20°C) and at an elevated temperature of 60°C when air pressure p of the soft actuator is turned off. Finally, a gripper composed of two fingers is fabricated for demonstration.

  13. Effects of Low-Intensity Pulsed Ultrasound for Preventing Joint Stiffness in Immobilized Knee Model in Rats.

    PubMed

    Itaya, Nobuyuki; Yabe, Yutake; Hagiwara, Yoshihiro; Kanazawa, Kenji; Koide, Masashi; Sekiguchi, Takuya; Yoshida, Shinichirou; Sogi, Yasuhito; Yano, Toshihisa; Tsuchiya, Masahiro; Saijo, Yoshihumi; Itoi, Eiji

    2018-06-01

    The purpose of this study was to examine the effect of low-intensity pulsed ultrasound (LIPUS) in preventing joint stiffness. Unilateral knee joints were immobilized in two groups of rats (n = 6/period/group). Under general anesthesia, the immobilized knee joints were exposed to LIPUS for 20 min/d, 5 d/wk, using an existing LIPUS device (LIPUS group, 1.5-MHz frequency, 1.0-kHz repetition cycle, 200-µs burst width and 30-mW/cm 2 power output) until endpoints (2, 4 or 6 wk). In the control group, general anesthesia alone was administered in the same manner as in the other group. The variables compared between the groups included joint angles; histologic, histomorphometric and immunohistochemical analyses; quantitative reverse transcription polymerase chain reactions; and tissue elasticity. LIPUS had a preventive effect on joint stiffness, resulting in decreased adhesion, fibrosis and inflammation and hypoxic response after joint immobilization. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  14. Linear Parameter Varying Identification of Dynamic Joint Stiffness during Time-Varying Voluntary Contractions

    PubMed Central

    Golkar, Mahsa A.; Sobhani Tehrani, Ehsan; Kearney, Robert E.

    2017-01-01

    Dynamic joint stiffness is a dynamic, nonlinear relationship between the position of a joint and the torque acting about it, which can be used to describe the biomechanics of the joint and associated limb(s). This paper models and quantifies changes in ankle dynamic stiffness and its individual elements, intrinsic and reflex stiffness, in healthy human subjects during isometric, time-varying (TV) contractions of the ankle plantarflexor muscles. A subspace, linear parameter varying, parallel-cascade (LPV-PC) algorithm was used to identify the model from measured input position perturbations and output torque data using voluntary torque as the LPV scheduling variable (SV). Monte-Carlo simulations demonstrated that the algorithm is accurate, precise, and robust to colored measurement noise. The algorithm was then used to examine stiffness changes associated with TV isometric contractions. The SV was estimated from the Soleus EMG using a Hammerstein model of EMG-torque dynamics identified from unperturbed trials. The LPV-PC algorithm identified (i) a non-parametric LPV impulse response function (LPV IRF) for intrinsic stiffness and (ii) a LPV-Hammerstein model for reflex stiffness consisting of a LPV static nonlinearity followed by a time-invariant state-space model of reflex dynamics. The results demonstrated that: (a) intrinsic stiffness, in particular ankle elasticity, increased significantly and monotonically with activation level; (b) the gain of the reflex pathway increased from rest to around 10–20% of subject's MVC and then declined; and (c) the reflex dynamics were second order. These findings suggest that in healthy human ankle, reflex stiffness contributes most at low muscle contraction levels, whereas, intrinsic contributions monotonically increase with activation level. PMID:28579954

  15. A comparison of muscle stiffness and musculoarticular stiffness of the knee joint in young athletic males and females.

    PubMed

    Wang, Dan; De Vito, Giuseppe; Ditroilo, Massimiliano; Fong, Daniel T P; Delahunt, Eamonn

    2015-06-01

    The objective of this study was to investigate the gender-specific differences in peak torque (PT), muscle stiffness (MS) and musculoarticular stiffness (MAS) of the knee joints in a young active population. Twenty-two male and twenty-two female recreational athletes participated. PT of the knee joint extensor musculature was assessed on an isokinetic dynamometer, MS of the vastus lateralis (VL) muscle was measured in both relaxed and contracted conditions, and knee joint MAS was quantified using the free oscillation technique. Significant gender differences were observed for all dependent variables. Females demonstrated less normalized PT (mean difference (MD)=0.4Nm/kg, p=0.005, η(2)=0.17), relaxed MS (MD=94.2N/m, p<.001, η(2)=0.53), contracted MS (MD=162.7N/m, p<.001, η(2)=0.53) and MAS (MD=422.1N/m, p<.001, η(2)=0.23) than males. MAS increased linearly with the external load in both genders with males demonstrating a significantly higher slope (p=0.019) than females. The observed differences outlined above may contribute to the higher knee joint injury incidence and prevalence in females when compared to males. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Estimation of Time-Varying, Intrinsic and Reflex Dynamic Joint Stiffness during Movement. Application to the Ankle Joint

    PubMed Central

    Guarín, Diego L.; Kearney, Robert E.

    2017-01-01

    Dynamic joint stiffness determines the relation between joint position and torque, and plays a vital role in the control of posture and movement. Dynamic joint stiffness can be quantified during quasi-stationary conditions using disturbance experiments, where small position perturbations are applied to the joint and the torque response is recorded. Dynamic joint stiffness is composed of intrinsic and reflex mechanisms that act and change together, so that nonlinear, mathematical models and specialized system identification techniques are necessary to estimate their relative contributions to overall joint stiffness. Quasi-stationary experiments have demonstrated that dynamic joint stiffness is heavily modulated by joint position and voluntary torque. Consequently, during movement, when joint position and torque change rapidly, dynamic joint stiffness will be Time-Varying (TV). This paper introduces a new method to quantify the TV intrinsic and reflex components of dynamic joint stiffness during movement. The algorithm combines ensemble and deterministic approaches for estimation of TV systems; and uses a TV, parallel-cascade, nonlinear system identification technique to separate overall dynamic joint stiffness into intrinsic and reflex components from position and torque records. Simulation studies of a stiffness model, whose parameters varied with time as is expected during walking, demonstrated that the new algorithm accurately tracked the changes in dynamic joint stiffness using as little as 40 gait cycles. The method was also used to estimate the intrinsic and reflex dynamic ankle stiffness from an experiment with a healthy subject during which ankle movements were imposed while the subject maintained a constant muscle contraction. The method identified TV stiffness model parameters that predicted the measured torque very well, accounting for more than 95% of its variance. Moreover, both intrinsic and reflex dynamic stiffness were heavily modulated through the movement in a manner that could not be predicted from quasi-stationary experiments. The new method provides the tool needed to explore the role of dynamic stiffness in the control of movement. PMID:28649196

  17. Torsional stiffness after subtalar arthrodesis using second generation headless compression screws: Biomechanical comparison of 2-screw and 3-screw fixation.

    PubMed

    Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E

    2017-06-01

    Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.

  18. Balance disorders caused by running and jumping occurring in young basketball players.

    PubMed

    Struzik, Artur; Zawadzki, Jerzy; Pietraszewski, Bogdan

    2015-01-01

    Body balance, as one of the coordination abilities,is a desirable variable for basketball players as regards the necessity of efficient responses in constantly changing situations on a basketball court. The aim of this study was to check whether physical activity in the form of running and jumping influences variables characterizing the process of keeping body balance of a basketball player in the standing position. The research was conducted on 11 young basketball players. The measurements were taken with a Kistler force plate. Apart from commonly registered COP displacements, an additional variable describing the process of keeping body balance by a basketball player was ankle joint stiffness on the basis of which an "Index of Balance-Stiffness" (IB-S) was created. Statistically significant differences were obtained for the maximum COP displacements and ankle joint stiffness between measurements of balance in the standing position before and after the employed movement tasks whereas there were no statistically significant differences for the aforementioned variables describing the process of keeping balance between measurements after running and after jumping. The research results indicate that the employed movement activities brought about significant changes in the process of keeping balance of basketball player in the standing position which, after the run performed, remain on a similar level to the series of jumps being performed. The authors attempted to establish an index based on the stiffness which yields a possibility to perceive each basketball player as an individual person in the process of keeping balance.

  19. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability.

    PubMed

    Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn

    2016-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability

    PubMed Central

    Gustafson, Jonathan A.; Gorman, Shannon; Fitzgerald, G. Kelley; Farrokhi, Shawn

    2017-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. PMID:26481256

  1. Characterization of the bending stiffness of large space structure joints

    NASA Technical Reports Server (NTRS)

    Wu, K. Chauncey

    1989-01-01

    A technique for estimating the bending stiffness of large space structure joints is developed and demonstrated for an erectable joint concept. Experimental load-deflection data from a three-point bending test was used as input to solve a closed-form expression for the joint bending stiffness which was derived from linear beam theory. Potential error sources in both the experimental and analytical procedures are identified and discussed. The bending stiffness of a mechanically preloaded erectable joint is studied at three applied moments and seven joint orientations. Using this technique, the joint bending stiffness was bounded between 6 and 17 percent of the bending stiffness of the graphite/epoxy strut member.

  2. Virtual trajectories of single-joint movements performed under two basic strategies.

    PubMed

    Latash, M L; Gottlieb, G L

    1992-01-01

    The framework of the equilibrium point hypothesis has been used to analyse motor control processes for single-joint movements. Virtual trajectories and joint stiffness were reconstructed for different movement speeds and distances when subjects were instructed either to move "as fast as possible" or to intentionally vary movement speed. These instructions are assumed to be associated with similar or different rates of change of hypothetical central control variables (corresponding to the speed-sensitive and speed-insensitive strategies). The subjects were trained to perform relatively slow, moderately fast and very fast (nominal movement times 800, 400 and 250 ms) single-joint elbow flexion movements against a constant extending torque bias. They were instructed to reproduce the motor command for a series of movements while ignoring possible changes in the external torque which could slowly and unpredictably increase, decrease, or remain constant. The total muscle torque was calculated as a sum of external and inertial components. Fast movements over different distances were made with the speed-insensitive strategy. They were characterized by an increase in joint stiffness near the midpoint of the movements which was relatively independent of movement amplitude. Their virtual trajectories had a non-monotonic N-shape. All three arms of the N-shape scaled with movement amplitude. Movements over one distance at different speeds were made with a speed-sensitive strategy. They demonstrated different patterns of virtual trajectories and joint stiffness that depended on movement speed. The N-shape became less apparent for moderately fast movements and virtually disappeared for the slow movements. Slow movements showed no visible increase in joint stiffness.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Comparison of plantar flexor musculotendinous stiffness, geometry, and architecture in male runners with and without a history of tibial stress fracture.

    PubMed

    Pamukoff, Derek N; Blackburn, J Troy

    2015-02-01

    Greater lower extremity joint stiffness may be related to the development of tibial stress fractures in runners. Musculotendinous stiffness is the largest contributor to joint stiffness, but it is unclear what factors contribute to musculotendinous stiffness. The purpose of this study was to compare plantar flexor musculotendinous stiffness, architecture, geometry, and Achilles tendon stiffness between male runners with and without a history of tibial stress fracture. Nineteen healthy runners (age = 21 ± 2.7 years; mass = 68.2 ± 9.3 kg; height = 177.3 ± 6.0 cm) and 19 runners with a history of tibial stress fracture (age = 21 ± 2.9 years; mass = 65.3 ± 6.0 kg; height = 177.2 ± 5.2 cm) were recruited from community running groups and the university's varsity and club cross-country teams. Plantar flexor musculotendinous stiffness was estimated from the damped frequency of oscillatory motion about the ankle follow perturbation. Ultrasound imaging was used to measure architecture and geometry of the medial gastrocnemius. Dependent variables were compared between groups via one-way ANOVAs. Previously injured runners had greater plantar flexor musculotendinous stiffness (P < .001), greater Achilles tendon stiffness (P = .004), and lesser Achilles tendon elongation (P = .003) during maximal isometric contraction compared with healthy runners. No differences were found in muscle thickness, pennation angle, or fascicle length.

  4. Biomechanical Effects of Stiffness in Parallel With the Knee Joint During Walking.

    PubMed

    Shamaei, Kamran; Cenciarini, Massimo; Adams, Albert A; Gregorczyk, Karen N; Schiffman, Jeffrey M; Dollar, Aaron M

    2015-10-01

    The human knee behaves similarly to a linear torsional spring during the stance phase of walking with a stiffness referred to as the knee quasi-stiffness. The spring-like behavior of the knee joint led us to hypothesize that we might partially replace the knee joint contribution during stance by utilizing an external spring acting in parallel with the knee joint. We investigated the validity of this hypothesis using a pair of experimental robotic knee exoskeletons that provided an external stiffness in parallel with the knee joints in the stance phase. We conducted a series of experiments involving walking with the exoskeletons with four levels of stiffness, including 0%, 33%, 66%, and 100% of the estimated human knee quasi-stiffness, and a pair of joint-less replicas. The results indicated that the ankle and hip joints tend to retain relatively invariant moment and angle patterns under the effects of the exoskeleton mass, articulation, and stiffness. The results also showed that the knee joint responds in a way such that the moment and quasi-stiffness of the knee complex (knee joint and exoskeleton) remains mostly invariant. A careful analysis of the knee moment profile indicated that the knee moment could fully adapt to the assistive moment; whereas, the knee quasi-stiffness fully adapts to values of the assistive stiffness only up to ∼80%. Above this value, we found biarticular consequences emerge at the hip joint.

  5. A stochastic Iwan-type model for joint behavior variability modeling

    NASA Astrophysics Data System (ADS)

    Mignolet, Marc P.; Song, Pengchao; Wang, X. Q.

    2015-08-01

    This paper focuses overall on the development and validation of a stochastic model to describe the dissipation and stiffness properties of a bolted joint for which experimental data is available and exhibits a large scatter. An extension of the deterministic parallel-series Iwan model for the characterization of the force-displacement behavior of joints is first carried out. This new model involves dynamic and static coefficients of friction differing from each other and a broadly defined distribution of Jenkins elements. Its applicability is next investigated using the experimental data, i.e. stiffness and dissipation measurements obtained in harmonic testing of 9 nominally identical bolted joints. The model is found to provide a very good fit of the experimental data for each bolted joint notwithstanding the significant variability of their behavior. This finding suggests that this variability can be simulated through the randomization of only the parameters of the proposed Iwan-type model. The distribution of these parameters is next selected based on maximum entropy concepts and their corresponding parameters, i.e. the hyperparameters of the model, are identified using a maximum likelihood strategy. Proceeding with a Monte Carlo simulation of this stochastic Iwan model demonstrates that the experimental data fits well within the uncertainty band corresponding to the 5th and 95th percentiles of the model predictions which well supports the adequacy of the modeling effort.

  6. The contribution of quasi-joint stiffness of the ankle joint to gait in patients with hemiparesis.

    PubMed

    Sekiguchi, Yusuke; Muraki, Takayuki; Kuramatsu, Yuko; Furusawa, Yoshihito; Izumi, Shin-Ichi

    2012-06-01

    The role of ankle joint stiffness during gait in patients with hemiparesis has not been clarified. The purpose of this study was to determine the contribution of quasi-joint stiffness of the ankle joint to spatiotemporal and kinetic parameters regarding gait in patients with hemiparesis due to brain tumor or stroke and healthy individuals. Spatiotemporal and kinetic parameters regarding gait in twelve patients with hemiparesis due to brain tumor or stroke and nine healthy individuals were measured with a 3-dimensional motion analysis system. Quasi-joint stiffness was calculated from the slope of the linear regression of the moment-angle curve of the ankle joint during the second rocker. There was no significant difference in quasi-joint stiffness among both sides of patients and the right side of controls. Quasi-joint stiffness on the paretic side of patients with hemiparesis positively correlated with maximal ankle power (r=0.73, P<0.01) and gait speed (r=0.66, P<0.05). In contrast, quasi-joint stiffness in controls negatively correlated with maximal ankle power (r=-0.73, P<0.05) and gait speed (r=-0.76, P<0.05). Our findings suggested that ankle power during gait might be generated by increasing quasi-joint stiffness in patients with hemiparesis. In contrast, healthy individuals might decrease quasi-joint stiffness to avoid deceleration of forward tilt of the tibia. Our findings might be useful for selecting treatment for increased ankle stiffness due to contracture and spasticity in patients with hemiparesis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Measurement of gastrocnemius muscle elasticity by shear wave elastography: association with passive ankle joint stiffness and sex differences.

    PubMed

    Chino, Kentaro; Takahashi, Hideyuki

    2016-04-01

    Passive joint stiffness is an important quantitative measure of flexibility, but is affected by muscle volume and all of the anatomical structures located within and over the joint. Shear wave elastography can assess muscle elasticity independent of the influences of muscle volume and the other nearby anatomical structures. We determined how muscle elasticity, as measured using shear wave elastography, is associated with passive joint stiffness and patient sex. Twenty-six healthy men (24.4 ± 5.9 years) and 26 healthy women (25.2 ± 4.8 years) participated in this study. The passive ankle joint stiffness and tissue elasticity of the medial gastrocnemius (MG) were quantified with the ankle in 30° plantar flexion (PF), a neutral anatomical position (NE), and 20° dorsiflexion (DF). No significant difference in passive joint stiffness by sex was observed with the ankle in PF, but significantly greater passive ankle joint stiffness in men than in women was observed in NE and DF. The MG elasticity was not significantly associated with joint stiffness in PF or NE, but it was significantly associated with joint stiffness in DF. There were no significant differences in MG elasticity by sex at any ankle position. Muscle elasticity, measured independent of the confounding effects of muscle volume and the other nearby anatomical structures, is associated with passive joint stiffness in the joint position where the muscle is sufficiently lengthened, but does not vary by sex in any joint position tested.

  8. Robust passive dynamics of the musculoskeletal system compensate for unexpected surface changes during human hopping

    PubMed Central

    van der Krogt, Marjolein M.; de Graaf, Wendy W.; Farley, Claire T.; Moritz, Chet T.; Richard Casius, L. J.; Bobbert, Maarten F.

    2009-01-01

    When human hoppers are surprised by a change in surface stiffness, they adapt almost instantly by changing leg stiffness, implying that neural feedback is not necessary. The goal of this simulation study was first to investigate whether leg stiffness can change without neural control adjustment when landing on an unexpected hard or unexpected compliant (soft) surface, and second to determine what underlying mechanisms are responsible for this change in leg stiffness. The muscle stimulation pattern of a forward dynamic musculoskeletal model was optimized to make the model match experimental hopping kinematics on hard and soft surfaces. Next, only surface stiffness was changed to determine how the mechanical interaction of the musculoskeletal model with the unexpected surface affected leg stiffness. It was found that leg stiffness adapted passively to both unexpected surfaces. On the unexpected hard surface, leg stiffness was lower than on the soft surface, resulting in close-to-normal center of mass displacement. This reduction in leg stiffness was a result of reduced joint stiffness caused by lower effective muscle stiffness. Faster flexion of the joints due to the interaction with the hard surface led to larger changes in muscle length, while the prescribed increase in active state and resulting muscle force remained nearly constant in time. Opposite effects were found on the unexpected soft surface, demonstrating the bidirectional stabilizing properties of passive dynamics. These passive adaptations to unexpected surfaces may be critical when negotiating disturbances during locomotion across variable terrain. PMID:19589956

  9. Can a Soft Robotic Probe Use Stiffness Control Like a Human Finger to Improve Efficacy of Haptic Perception?

    PubMed

    Sornkarn, Nantachai; Nanayakkara, Thrishantha

    2017-01-01

    When humans are asked to palpate a soft tissue to locate a hard nodule, they regulate the stiffness, speed, and force of the finger during examination. If we understand the relationship between these behavioral variables and haptic information gain (transfer entropy) during manual probing, we can improve the efficacy of soft robotic probes for soft tissue palpation, such as in tumor localization in minimally invasive surgery. Here, we recorded the muscle co-contraction activity of the finger using EMG sensors to address the question as to whether joint stiffness control during manual palpation plays an important role in the haptic information gain. To address this question, we used a soft robotic probe with a controllable stiffness joint and a force sensor mounted at the base to represent the function of the tendon in a biological finger. Then, we trained a Markov chain using muscle co-contraction patterns of human subjects, and used it to control the stiffness of the soft robotic probe in the same soft tissue palpation task. The soft robotic experiments showed that haptic information gain about the depth of the hard nodule can be maximized by varying the internal stiffness of the soft probe.

  10. Self-Myofascial Release: No Improvement of Functional Outcomes in 'Tight' Hamstrings.

    PubMed

    Morton, Robert W; Oikawa, Sara Y; Phillips, Stuart M; Devries, Michaela C; Mitchell, Cameron J

    2016-07-01

    Self-myofascial release (SMR) is a common exercise and therapeutic modality shown to induce acute improvements in joint range of motion (ROM) and recovery; however, no long-term studies have been conducted. Static stretching (SS) is the most common method used to increase joint ROM and decrease muscle stiffness. It was hypothesized that SMR paired with SS (SMR+SS) compared with SS alone over a 4-wk intervention would yield greater improvement in knee-extension ROM and hamstring stiffness. 19 men (22 ± 3 y) with bilateral reduced hamstring ROM had each of their legs randomly assigned to either an SMR+SS or an SS-only group. The intervention consisted of 4 repetitions of SS each for 45 s or the identical amount of SS preceded by 4 repetitions of SMR each for 60 s and was performed on the respective leg twice daily for 4 wk. Passive ROM, hamstring stiffness, rate of torque development (RTD), and maximum voluntary contraction (MVC) were assessed pre- and postintervention. Passive ROM (P < .001), RTD, and MVC (P < .05) all increased after the intervention. Hamstring stiffness toward end-ROM was reduced postintervention (P = .02). There were no differences between the intervention groups for any variable. The addition of SMR to SS did not enhance the efficacy of SS alone. SS increases joint ROM through a combination of decreased muscle stiffness and increased stretch tolerance.

  11. Exploratory factor analysis for differentiating sensory and mechanical variables related to muscle-tendon unit elongation

    PubMed Central

    Chagas, Mauro H.; Magalhães, Fabrício A.; Peixoto, Gustavo H. C.; Pereira, Beatriz M.; Andrade, André G. P.; Menzel, Hans-Joachim K.

    2016-01-01

    ABSTRACT Background Stretching exercises are able to promote adaptations in the muscle-tendon unit (MTU), which can be tested through physiological and biomechanical variables. Identifying the key variables in MTU adaptations is crucial to improvements in training. Objective To perform an exploratory factor analysis (EFA) involving the variables often used to evaluate the response of the MTU to stretching exercises. Method Maximum joint range of motion (ROMMAX), ROM at first sensation of stretching (FSTROM), peak torque (torqueMAX), passive stiffness, normalized stiffness, passive energy, and normalized energy were investigated in 36 participants during passive knee extension on an isokinetic dynamometer. Stiffness and energy values were normalized by the muscle cross-sectional area and their passive mode assured by monitoring the EMG activity. Results EFA revealed two major factors that explained 89.68% of the total variance: 53.13% was explained by the variables torqueMAX, passive stiffness, normalized stiffness, passive energy, and normalized energy, whereas the remaining 36.55% was explained by the variables ROMMAX and FSTROM. Conclusion This result supports the literature wherein two main hypotheses (mechanical and sensory theories) have been suggested to describe the adaptations of the MTU to stretching exercises. Contrary to some studies, in the present investigation torqueMAX was significantly correlated with the variables of the mechanical theory rather than those of the sensory theory. Therefore, a new approach was proposed to explain the behavior of the torqueMAX during stretching exercises. PMID:27437715

  12. Increase in Leg Stiffness Reduces Joint Work During Backpack Carriage Running at Slow Velocities.

    PubMed

    Liew, Bernard; Netto, Kevin; Morris, Susan

    2017-10-01

    Optimal tuning of leg stiffness has been associated with better running economy. Running with a load is energetically expensive, which could have a significant impact on athletic performance where backpack carriage is involved. The purpose of this study was to investigate the impact of load magnitude and velocity on leg stiffness. We also explored the relationship between leg stiffness and running joint work. Thirty-one healthy participants ran overground at 3 velocities (3.0, 4.0, 5.0 m·s -1 ), whilst carrying 3 load magnitudes (0%, 10%, 20% weight). Leg stiffness was derived using the direct kinetic-kinematic method. Joint work data was previously reported in a separate study. Linear models were used to establish relationships between leg stiffness and load magnitude, velocity, and joint work. Our results found that leg stiffness did not increase with load magnitude. Increased leg stiffness was associated with reduced total joint work at 3.0 m·s -1 , but not at faster velocities. The association between leg stiffness and joint work at slower velocities could be due to an optimal covariation between skeletal and muscular components of leg stiffness, and limb attack angle. When running at a relatively comfortable velocity, greater leg stiffness may reflect a more energy efficient running pattern.

  13. Self-reported knee joint instability is related to passive mechanical stiffness in medial knee osteoarthritis.

    PubMed

    Creaby, Mark W; Wrigley, Tim V; Lim, Boon-Whatt; Hinman, Rana S; Bryant, Adam L; Bennell, Kim L

    2013-11-20

    Self-reported knee joint instability compromises function in individuals with medial knee osteoarthritis and may be related to impaired joint mechanics. The purpose of this study was to evaluate the relationship between self-reported instability and the passive varus-valgus mechanical behaviour of the medial osteoarthritis knee. Passive varus-valgus angular laxity and stiffness were assessed using a modified isokinetic dynamometer in 73 participants with medial tibiofemoral osteoarthritis. All participants self-reported the absence or presence of knee instability symptoms and the degree to which instability affected daily activity on a 6-point likert scale. Forward linear regression modelling identified a significant inverse relationship between passive mid-range knee stiffness and symptoms of knee instability (r = 0.27; P < 0.05): reduced stiffness was indicative of more severe instability symptoms. Angular laxity and end-range stiffness were not related to instability symptoms (P > 0.05). Conceivably, a stiffer passive system may contribute toward greater joint stability during functional activities. Importantly however, net joint stiffness is influenced by both active and passive stiffness, and thus the active neuromuscular system may compensate for reduced passive stiffness in order to maintain joint stability. Future work is merited to examine the role of active stiffness in symptomatic joint stability.

  14. Self-reported knee joint instability is related to passive mechanical stiffness in medial knee osteoarthritis

    PubMed Central

    2013-01-01

    Background Self-reported knee joint instability compromises function in individuals with medial knee osteoarthritis and may be related to impaired joint mechanics. The purpose of this study was to evaluate the relationship between self-reported instability and the passive varus-valgus mechanical behaviour of the medial osteoarthritis knee. Methods Passive varus-valgus angular laxity and stiffness were assessed using a modified isokinetic dynamometer in 73 participants with medial tibiofemoral osteoarthritis. All participants self-reported the absence or presence of knee instability symptoms and the degree to which instability affected daily activity on a 6-point likert scale. Results Forward linear regression modelling identified a significant inverse relationship between passive mid-range knee stiffness and symptoms of knee instability (r = 0.27; P < 0.05): reduced stiffness was indicative of more severe instability symptoms. Angular laxity and end-range stiffness were not related to instability symptoms (P > 0.05). Conclusions Conceivably, a stiffer passive system may contribute toward greater joint stability during functional activities. Importantly however, net joint stiffness is influenced by both active and passive stiffness, and thus the active neuromuscular system may compensate for reduced passive stiffness in order to maintain joint stability. Future work is merited to examine the role of active stiffness in symptomatic joint stability. PMID:24252592

  15. Modeling and simulating the neuromuscular mechanisms regulating ankle and knee joint stiffness during human locomotion.

    PubMed

    Sartori, Massimo; Maculan, Marco; Pizzolato, Claudio; Reggiani, Monica; Farina, Dario

    2015-10-01

    This work presents an electrophysiologically and dynamically consistent musculoskeletal model to predict stiffness in the human ankle and knee joints as derived from the joints constituent biological tissues (i.e., the spanning musculotendon units). The modeling method we propose uses electromyography (EMG) recordings from 13 muscle groups to drive forward dynamic simulations of the human leg in five healthy subjects during overground walking and running. The EMG-driven musculoskeletal model estimates musculotendon and resulting joint stiffness that is consistent with experimental EMG data as well as with the experimental joint moments. This provides a framework that allows for the first time observing 1) the elastic interplay between the knee and ankle joints, 2) the individual muscle contribution to joint stiffness, and 3) the underlying co-contraction strategies. It provides a theoretical description of how stiffness modulates as a function of muscle activation, fiber contraction, and interacting tendon dynamics. Furthermore, it describes how this differs from currently available stiffness definitions, including quasi-stiffness and short-range stiffness. This work offers a theoretical and computational basis for describing and investigating the neuromuscular mechanisms underlying human locomotion. Copyright © 2015 the American Physiological Society.

  16. Modeling and simulating the neuromuscular mechanisms regulating ankle and knee joint stiffness during human locomotion

    PubMed Central

    Maculan, Marco; Pizzolato, Claudio; Reggiani, Monica; Farina, Dario

    2015-01-01

    This work presents an electrophysiologically and dynamically consistent musculoskeletal model to predict stiffness in the human ankle and knee joints as derived from the joints constituent biological tissues (i.e., the spanning musculotendon units). The modeling method we propose uses electromyography (EMG) recordings from 13 muscle groups to drive forward dynamic simulations of the human leg in five healthy subjects during overground walking and running. The EMG-driven musculoskeletal model estimates musculotendon and resulting joint stiffness that is consistent with experimental EMG data as well as with the experimental joint moments. This provides a framework that allows for the first time observing 1) the elastic interplay between the knee and ankle joints, 2) the individual muscle contribution to joint stiffness, and 3) the underlying co-contraction strategies. It provides a theoretical description of how stiffness modulates as a function of muscle activation, fiber contraction, and interacting tendon dynamics. Furthermore, it describes how this differs from currently available stiffness definitions, including quasi-stiffness and short-range stiffness. This work offers a theoretical and computational basis for describing and investigating the neuromuscular mechanisms underlying human locomotion. PMID:26245321

  17. The bending stiffness of shoes is beneficial to running energetics if it does not disturb the natural MTP joint flexion.

    PubMed

    Oh, Keonyoung; Park, Sukyung

    2017-02-28

    A local minimum for running energetics has been reported for a specific bending stiffness, implying that shoe stiffness assists in running propulsion. However, the determinant of the metabolic optimum remains unknown. Highly stiff shoes significantly increase the moment arm of the ground reaction force (GRF) and reduce the leverage effect of joint torque at ground push-off. Inspired by previous findings, we hypothesized that the restriction of the natural metatarsophalangeal (MTP) flexion caused by stiffened shoes and the corresponding joint torque changes may reduce the benefit of shoe bending stiffness to running energetics. We proposed the critical stiffness, k cr , which is defined as the ratio of the MTP joint (MTPJ) torque to the maximal MTPJ flexion angle, as a possible threshold of the elastic benefit of shoe stiffness. 19 subjects participated in a running test while wearing insoles with five different bending stiffness levels. Joint angles, GRFs, and metabolic costs were measured and analyzed as functions of the shoe stiffness. No significant changes were found in the take-off velocity of the center of mass (CoM), but the horizontal ground push-offs were significantly reduced at different shoe stiffness levels, indicating that complementary changes in the lower-limb joint torques were introduced to maintain steady running. Slight increases in the ankle, knee, and hip joint angular impulses were observed at stiffness levels exceeding the critical stiffness, whereas the angular impulse at the MTPJ was significantly reduced. These results indicate that the shoe bending stiffness is beneficial to running energetics if it does not disturb the natural MTPJ flexion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. A model-based approach to stabilizing crutch supported paraplegic standing by artificial hip joint stiffness.

    PubMed

    van der Spek, Jaap H; Veltink, Peter H; Hermens, Hermie J; Koopman, Bart F J M; Boom, Herman B K

    2003-12-01

    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hip-joint stiffness for changing crutch placement and hip-joint offset angle was studied under static and dynamic conditions. Modeling results indicate that, by using additional hip-joint stiffness, stable crutch supported paraplegic standing can be achieved, both under static as well as dynamic situations. The static equilibrium postures and the stability under perturbations were calculated to be dependent on crutch placement and stiffness applied. However, postures in which the hip joint was in extension (C postures) appeared to the most stable postures. Applying at least 60 N x m/rad hip-joint stiffness gave stable equilibrium postures in all cases. Choosing appropriate hip-joint offset angles, the static equilibrium postures changed to more erect postures, without causing instability or excessive arm forces to occur.

  19. Nervous system excitability and joint stiffness following short-term dynamic ankle immobilization.

    PubMed

    Stirling, Alyssa M; McBride, Jeffrey M; Merritt, Edward K; Needle, Alan R

    2018-01-01

    Joint immobilization has been demonstrated to modify neural excitability in subsets of healthy populations, leading to disinhibition of cortical and reflexive pathways. However, these findings may have limited clinical application as most models have investigated casting and rigid immobilization, while many musculoskeletal injuries often utilize dynamic immobilization devices such as boot immobilizers and pneumatic splints that allow for modified ambulation. We therefore aimed to determine the short-term effects of ambulation in ankle immobilization devices on nervous system excitability and stiffness in able-bodied individuals. A repeated-measures design was implemented where 12 healthy individuals were tested for cortical excitability to the ankle musculature using transcranial magnetic stimulation, reflexive excitability using the Hoffmann reflex, and ankle joint stiffness using arthrometry before and after 30min of ambulation with a boot immobilizer, pneumatic leg splint, or barefoot. Motor evoked potential (MEP), cortical silent period (CSP), H max to M max ratio, and ankle joint displacement were extracted as dependent variables. Results indicated that despite the novel motor demands of walking in immobilization devices, no significant changes in cortical excitability (F≥0.335, P≥0.169), reflexive excitability (F≥0.027, P≥0.083), or joint stiffness (F≥0.558, P≥0.169) occurred. These findings indicate that short-term ambulation in dynamic immobilization devices does not modify neural excitability despite forced constraints on the sensorimotor system. We may therefore conclude that modifications to neural excitability in previous immobilization models are mediated by long-term nervous system plasticity rather than acute mechanisms, and there appear to be no robust changes in corticomotor or spinal excitability acutely posed by ambulation with immobilization devices. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Structural performance of light-frame roof assemblies. I, Truss assemblies designed for high variability and wood failure

    Treesearch

    R.W. Wolfe; Monica McCarthy

    1989-01-01

    The first report of a three-part series that covers results of a full-scale roof assemblies research program. The focus of this report is the structural performance of truss assemblies comprising trusses with abnormally high stiffness variability and critical joint strength. Results discussed include properties of truss members and connections. individual truss...

  1. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    PubMed Central

    Avgoulas, Evangelos I.; Sutcliffe, Michael P. F.

    2016-01-01

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints. PMID:28773688

  2. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints.

    PubMed

    Avgoulas, Evangelos I; Sutcliffe, Michael P F

    2016-07-12

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  3. Estimation of joint stiffness with a compliant load.

    PubMed

    Ludvig, Daniel; Kearney, Robert E

    2009-01-01

    Joint stiffness defines the dynamic relationship between the position of the joint and the torque acting about it. It consists of two components: intrinsic and reflex stiffness. Many previous studies have investigated joint stiffness in an open-loop environment, because the current algorithm in use is an open-loop algorithm. This paper explores issues related to the estimation of joint stiffness when subjects interact with compliant loads. First, we show analytically how the bias in closed-loop estimates of joint stiffness depends on the properties of the load, the noise power, and length of the estimated impulse response functions (IRF). We then demonstrate with simulations that the open-loop analysis will fail completely for an elastic load but may succeed for an inertial load. We further show that the open-loop analysis can yield unbiased results with an inertial load and document IRF length, signal-to-noise ratio needed, and minimum inertia needed for the analysis to succeed. Thus, by using a load with a properly selected inertia, open-loop analysis can be used under closed-loop conditions.

  4. Joint stiffness and running economy during imposed forefoot strike before and after a long run in rearfoot strike runners.

    PubMed

    Melcher, Daniel A; Paquette, Max R; Schilling, Brian K; Bloomer, Richard J

    2017-12-01

    Research has focused on the effects of acute strike pattern modifications on lower extremity joint stiffness and running economy (RE). Strike pattern modifications on running biomechanics have mostly been studied while runners complete short running bouts. This study examined the effects of an imposed forefoot strike (FFS) on RE and ankle and knee joint stiffness before and after a long run in habitual rearfoot strike (RFS) runners. Joint kinetics and RE were collected before and after a long run. Sagittal joint kinetics were computed from kinematic and ground reaction force data that were collected during over-ground running trials in 13 male runners. RE was measured during treadmill running. Knee flexion range of motion, knee extensor moment and ankle joint stiffness were lower while plantarflexor moment and knee joint stiffness were greater during imposed FFS compared with RFS. The long run did not influence the difference in ankle and knee joint stiffness between strike patterns. Runners were more economical during RFS than imposed FFS and RE was not influenced by the long run. These findings suggest that using a FFS pattern towards the end of a long run may not be mechanically or metabolically beneficial for well-trained male RFS runners.

  5. Differences in neutral foot positions when measured barefoot compared to in shoes with varying stiffnesses.

    PubMed

    Shultz, R; Birmingham, T B; Jenkyn, T R

    2011-12-01

    This study examined the absolute differences in neutral positions of the joints of the foot with different footwear. This addresses the question of whether separate static trials should be collected for each footwear condition to establish neutral positions. A multi-segment kinematic foot model and optical motion analysis system measured four inter-segmental joints of the foot: (1) hindfoot-to-midfoot in the frontal plane, (2) forefoot-to-midfoot in the frontal plane, (3) hallux-to-forefoot in the sagittal plane, and (4) the height-to-length ratio of the medial longitudinal arch. Barefoot was compared to three shoe condition using Nike Free trainers of varying longitudinal torsional stiffness in ten male volunteers. There was high variability both within subjects and shoe conditions. Shoes in general tended to raise the medial longitudinal arch and dorsiflex the hallux compared to barefoot condition. For the hallux, a minimum important difference of 5° or more was found between shoe conditions and the barefoot condition for majority of the subjects in all three shoe conditions (90% for control, 60% for least stiff, 50% for most stiff). This was less for the frontal plane inter-segmental joints of the foot where 50% of the subjects experience a change above 5° for at least one of the conditions. The choice of using condition-specific neutral trials versus a single common neutral trials should be considered carefully. A single common trial allows for differences in absolute joint angles to be compared between footwear conditions. This can be important clinically to determine whether a joint is approaching its end-of-range and therefore at risk of injury. Several condition-specific neutral trials allows for subtleties in kinematic waveforms to be better compared between conditions, since absolute shifts in joint angles due to changing neutral position are removed and the waveforms are better aligned. Copyright © 2011. Published by Elsevier Ltd.

  6. Idiopathic toe-walking in children, adolescents and young adults: a matter of local or generalised stiffness?

    PubMed Central

    2011-01-01

    Background Idiopathic Toe Walking (ITW) is present in children older than 3 years of age still walking on their toes without signs of neurological, orthopaedic or psychiatric diseases. ITW has been estimated to occur in 7% to 24% of the childhood population. To study associations between Idiopathic Toe Walking (ITW) and decrease in range of joint motion of the ankle joint. To study associations between ITW (with stiff ankles) and stiffness in other joints, muscle strength and bone density. Methods In a cross-sectional study, 362 healthy children, adolescents and young adults (mean age (sd): 14.2 (3.9) years) participated. Range of joint motion (ROM), muscle strength, anthropometrics sport activities and bone density were measured. Results A prevalence of 12% of ITW was found. Nine percent had ITW and severely restricted ROM of the ankle joint. Children with ITW had three times higher chance of severe ROM restriction of the ankle joint. Participants with ITW and stiff ankle joints had a decreased ROM in other joints, whereas bone density and muscle strength were comparable. Conclusion ITW and a decrease in ankle joint ROM might be due to local stiffness. Differential etiological diagnosis should be considered. PMID:21418634

  7. Idiopathic toe-walking in children, adolescents and young adults: a matter of local or generalised stiffness?

    PubMed

    Engelbert, Raoul; Gorter, Jan Willem; Uiterwaal, Cuno; van de Putte, Elise; Helders, Paul

    2011-03-21

    Idiopathic Toe Walking (ITW) is present in children older than 3 years of age still walking on their toes without signs of neurological, orthopaedic or psychiatric diseases. ITW has been estimated to occur in 7% to 24% of the childhood population. To study associations between Idiopathic Toe Walking (ITW) and decrease in range of joint motion of the ankle joint. To study associations between ITW (with stiff ankles) and stiffness in other joints, muscle strength and bone density. In a cross-sectional study, 362 healthy children, adolescents and young adults (mean age (sd): 14.2 (3.9) years) participated. Range of joint motion (ROM), muscle strength, anthropometrics sport activities and bone density were measured. A prevalence of 12% of ITW was found. Nine percent had ITW and severely restricted ROM of the ankle joint. Children with ITW had three times higher chance of severe ROM restriction of the ankle joint. Participants with ITW and stiff ankle joints had a decreased ROM in other joints, whereas bone density and muscle strength were comparable. ITW and a decrease in ankle joint ROM might be due to local stiffness. Differential etiological diagnosis should be considered.

  8. Estimating the Mechanical Behavior of the Knee Joint during Crouch Gait: Implications for Real-Time Motor Control of Robotic Knee Orthoses

    PubMed Central

    Damiano, Diane L.; Bulea, Thomas C.

    2016-01-01

    Individuals with cerebral palsy frequently exhibit crouch gait, a pathological walking pattern characterized by excessive knee flexion. Knowledge of the knee joint moment during crouch gait is necessary for the design and control of assistive devices used for treatment. Our goal was to 1) develop statistical models to estimate knee joint moment extrema and dynamic stiffness during crouch gait, and 2) use the models to estimate the instantaneous joint moment during weight-acceptance. We retrospectively computed knee moments from 10 children with crouch gait and used stepwise linear regression to develop statistical models describing the knee moment features. The models explained at least 90% of the response value variability: peak moment in early (99%) and late (90%) stance, and dynamic stiffness of weight-acceptance flexion (94%) and extension (98%). We estimated knee extensor moment profiles from the predicted dynamic stiffness and instantaneous knee angle. This approach captured the timing and shape of the computed moment (root-mean-squared error: 2.64 Nm); including the predicted early-stance peak moment as a correction factor improved model performance (root-mean-squared error: 1.37 Nm). Our strategy provides a practical, accurate method to estimate the knee moment during crouch gait, and could be used for real-time, adaptive control of robotic orthoses. PMID:27101612

  9. Evaluating the Ergonomic Benefit of a Wrist Brace on Wrist Posture, Muscle Activity, Rotational Stiffness, and Peak Shovel-Ground Impact Force During a Simulated Tree-Planting Task.

    PubMed

    Sheahan, Peter J; Cashaback, Joshua G A; Fischer, Steven L

    2017-09-01

    Background Tree planters are at a high risk for wrist injury due to awkward postures and high wrist loads experienced during each planting cycle, specifically at shovel-ground impact. Wrist joint stiffness provides a measure that integrates postural and loading information. Objective The purpose of this study was to evaluate wrist joint stiffness requirements at the instant of shovel-ground impact during tree planting and determine if a wrist brace could alter muscular contributions to wrist joint stiffness. Method Planters simulated tree planting with and without wearing a brace on their planting arm. Surface electromyography (sEMG) from six forearm muscles and wrist kinematics were collected and used to calculate muscular contributions to joint rotational stiffness about the wrist. Results Wrist joint stiffness increased with brace use, an unanticipated and negative consequence of wearing a brace. As a potential benefit, planters achieved a more neutrally oriented wrist angle about the flexion/extension axis, although a less neutral wrist angle about the ulnar/radial axis was observed. Muscle activity did not change between conditions. Conclusion The joint stiffness analysis, combining kinematic and sEMG information in a biologically relevant manner, revealed clear limitations with the interface between the brace grip and shovel handle that jeopardized the prophylactic benefits of the current brace design. This limitation was not as evident when considering kinematics and sEMG data independently. Application A neuromechanical model (joint rotational stiffness) enhanced our ability to evaluate the brace design relative to kinematic and sEMG parameter-based metrics alone.

  10. Spatial and temporal modulation of joint stiffness during multijoint movement.

    PubMed

    Mah, C D

    2001-02-01

    Joint stiffness measurements during small transient perturbations have suggested that stiffness during movement is different from that observed during posture. These observations are problematic for theories like the classical equilibrium point hypothesis, which suggest that desired trajectories during movement are enforced by joint stiffness. We measured arm impedances during large, slow perturbations to obtain detailed information about the spatial and temporal modulation of stiffness and viscosity during movement. While our measurements of stiffness magnitudes during movement generally agreed with the results of measurements using fast perturbations, they revealed that joint stiffness undergoes stereotyped changes in magnitude and aspect ratio which depend on the direction of movement and show a strong dependence on joint angles. Movement simulations using measured parameters show that the measured modulation of impedance acts as an energy conserving force field to constrain movement. This mechanism allows for a computationally simplified account of the execution of multijoint movement. While our measurements do not rule out a role for afferent feedback in force generation, the observed stereotyped restoring forces can allow a dramatic relaxation of the accuracy requirements for forces generated by other control mechanisms, such as inverse dynamical models.

  11. Measurement of the passive stiffness of ankle joint in 3 DOF using stewart platform type ankle foot device.

    PubMed

    Nomura, Kenta; Yonezawa, Teru; Mizoguchi, Hiroshi; Takemura, Hiroshi

    2016-08-01

    This paper presents a method to measure the passive stiffness of an ankle joint in three degrees of freedom (DOF) under two motion speeds (1 Hz and 5 degree/s) using a developed Stewart platform-type device. The developed device can reproduce input motions of the foot in 6 DOF by controlling six pneumatic linear motion actuators. We used the device to measure the passive stiffness of an ankle joint undergoing three kinds of motion, namely dorsi-plantar flexion, inversion-eversion, and adduction-abduction. The measured values of the passive stiffness of the ankle joint in dorsiflexion that we obtained agreed well with that obtained in a previous study, indicating that the developed device is useful for measuring the passive stiffness of ankle joint. In addition, the developed device can be used to measure the stiffness in inversion-eversion and adduction-abduction motions as well, parameters that have never been measured. The results we obtained demonstrated certain interesting features as we varied both the direction and pace of motion (e.g., there were significant differences in the stiffness not only between adduction and abduction during the faster pace, but also between these and the other motions).

  12. Can chronic stretching change the muscle-tendon mechanical properties? A review.

    PubMed

    Freitas, S R; Mendes, B; Le Sant, G; Andrade, R J; Nordez, A; Milanovic, Z

    2018-03-01

    It is recognized that stretching is an effective method to chronically increase the joint range of motion. However, the effects of stretching training on the muscle-tendon structural properties remain unclear. This systematic review with meta-analysis aimed to determine whether chronic stretching alter the muscle-tendon structural properties. Published papers regarding longitudinal stretching (static, dynamic and/or PNF) intervention (either randomized or not) in humans of any age and health status, with more than 2 weeks in duration and at least 2 sessions per week, were searched in PubMed, PEDro, ScienceDirect and ResearchGate databases. Structural or mechanical variables from joint (maximal tolerated passive torque or resistance to stretch) or muscle-tendon unit (muscle architecture, stiffness, extensibility, shear modulus, volume, thickness, cross-sectional area, and slack length) were extracted from those papers. A total of 26 studies were selected, with a duration ranging from 3 to 8 weeks, and an average total time under stretching of 1165 seconds per week. Small effects were seen for maximal tolerated passive torque, but trivial effects were seen for joint resistance to stretch, muscle architecture, muscle stiffness, and tendon stiffness. A large heterogeneity was seen for most of the variables. Stretching interventions with 3- to 8-week duration do not seem to change either the muscle or the tendon properties, although it increases the extensibility and tolerance to a greater tensile force. Adaptations to chronic stretching protocols shorter than 8 weeks seem to mostly occur at a sensory level. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Estimation of Quasi-Stiffness and Propulsive Work of the Human Ankle in the Stance Phase of Walking

    PubMed Central

    Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.

    2013-01-01

    Characterizing the quasi-stiffness and work of lower extremity joints is critical for evaluating human locomotion and designing assistive devices such as prostheses and orthoses intended to emulate the biological behavior of human legs. This work aims to establish statistical models that allow us to predict the ankle quasi-stiffness and net mechanical work for adults walking on level ground. During the stance phase of walking, the ankle joint propels the body through three distinctive phases of nearly constant stiffness known as the quasi-stiffness of each phase. Using a generic equation for the ankle moment obtained through an inverse dynamics analysis, we identify key independent parameters needed to predict ankle quasi-stiffness and propulsive work and also the functional form of each correlation. These parameters include gait speed, ankle excursion, and subject height and weight. Based on the identified form of the correlation and key variables, we applied linear regression on experimental walking data for 216 gait trials across 26 subjects (speeds from 0.75–2.63 m/s) to obtain statistical models of varying complexity. The most general forms of the statistical models include all the key parameters and have an R2 of 75% to 81% in the prediction of the ankle quasi-stiffnesses and propulsive work. The most specific models include only subject height and weight and could predict the ankle quasi-stiffnesses and work for optimal walking speed with average error of 13% to 30%. We discuss how these models provide a useful framework and foundation for designing subject- and gait-specific prosthetic and exoskeletal devices designed to emulate biological ankle function during level ground walking. PMID:23555839

  14. Biomechanical response to ankle-foot orthosis stiffness during running.

    PubMed

    Russell Esposito, Elizabeth; Choi, Harmony S; Owens, Johnny G; Blanck, Ryan V; Wilken, Jason M

    2015-12-01

    The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is an ankle-foot orthosis developed to address the high rates of delayed amputation in the military. Its use has enabled many wounded Service Members to run again. During running, stiffness is thought to influence an orthosis' energy storage and return mechanical properties. This study examined the effect of orthosis stiffness on running biomechanics in patients with lower limb impairments who had undergone unilateral limb salvage. Ten patients with lower limb impairments underwent gait analysis at a self-selected running velocity. 1. Nominal (clinically-prescribed), 2. Stiff (20% stiffer than nominal), and 3. Compliant (20% less stiff than nominal) ankle-foot orthosis stiffnesses were tested. Ankle joint stiffness was greatest in the stiffest strut and lowest in the compliant strut, however ankle mechanical work remained unchanged. Speed, stride length, cycle time, joint angles, moments, powers, and ground reaction forces were not significantly different among stiffness conditions. Ankle joint kinematics and ankle, knee and hip kinetics were different between limbs. Ankle power, in particular, was lower in the injured limb. Ankle-foot orthosis stiffness affected ankle joint stiffness but did not influence other biomechanical parameters of running in individuals with unilateral limb salvage. Foot strike asymmetries may have influenced the kinetics of running. Therefore, a range of stiffness may be clinically appropriate when prescribing ankle-foot orthoses for active individuals with limb salvage. Published by Elsevier Ltd.

  15. An experimental and morphometric test of the relationship between vertebral morphology and joint stiffness in Nile crocodiles (Crocodylus niloticus).

    PubMed

    Molnar, Julia L; Pierce, Stephanie E; Hutchinson, John R

    2014-03-01

    Despite their semi-aquatic mode of life, modern crocodylians use a wide range of terrestrial locomotor behaviours, including asymmetrical gaits otherwise only found in mammals. The key to these diverse abilities may lie in the axial skeleton. Correlations between vertebral morphology and both intervertebral joint stiffness and locomotor behaviour have been found in other animals, but the vertebral mechanics of crocodylians have not yet been experimentally and quantitatively tested. We measured the passive mechanics and morphology of the thoracolumbar vertebral column in Crocodylus niloticus in order to validate a method to infer intervertebral joint stiffness based on morphology. Passive stiffness of eight thoracic and lumbar joints was tested in dorsal extension, ventral flexion and mediolateral flexion using cadaveric specimens. Fifteen measurements that we deemed to be potential correlates of stiffness were taken from each vertebra and statistically tested for correlation with joint stiffness. We found that the vertebral column of C. niloticus is stiffer in dorsoventral flexion than in lateral flexion and, in contrast to that of many mammals, shows an increase in joint stiffness in the lumbar region. Our findings suggest that the role of the axial column in crocodylian locomotion may be functionally different from that in mammals, even during analogous gaits. A moderate proportion of variation in joint stiffness (R(2)=0.279-0.520) was predicted by centrum width and height, neural spine angle and lamina width. These results support the possible utility of some vertebral morphometrics in predicting mechanical properties of the vertebral column in crocodiles, which also should be useful for forming functional hypotheses of axial motion during locomotion in extinct archosaurs.

  16. Soldier-relevant body borne loads increase knee joint contact force during a run-to-stop maneuver.

    PubMed

    Ramsay, John W; Hancock, Clifford L; O'Donovan, Meghan P; Brown, Tyler N

    2016-12-08

    The purpose of this study was to understand the effects of load carriage on human performance, specifically during a run-to-stop (RTS) task. Using OpenSim analysis tools, knee joint contact force, grounds reaction force, leg stiffness and lower extremity joint angles and moments were determined for nine male military personnel performing a RTS under three load configurations (light, ~6kg, medium, ~20kg, and heavy, ~40kg). Subject-based means for each biomechanical variable were submitted to repeated measures ANOVA to test the effects of load. During the RTS, body borne load significantly increased peak knee joint contact force by 1.2 BW (p<0.001) and peak vertical (p<0.001) and anterior-posterior (p=0.002) ground reaction forces by 0.6 BW and 0.3 BW, respectively. Body borne load also had a significant effect on hip (p=0.026) posture with the medium load and knee (p=0.046) posture with the heavy load. With the heavy load, participants exhibited a substantial, albeit non-significant increase in leg stiffness (p=0.073 and d=0.615). Increases in joint contact force exhibited during the RTS were primarily due to greater GRFs that impact the soldier with each incremental addition of body borne load. The stiff leg, extended knee and large braking force the soldiers exhibited with the heavy load suggests their injury risk may be greatest with that specific load configuration. Further work is needed to determine if the biomechanical profile exhibited with the heavy load configuration translates to unsafe shear forces at the knee joint and consequently, a higher likelihood of injury. Published by Elsevier Ltd.

  17. Subspace methods for identification of human ankle joint stiffness.

    PubMed

    Zhao, Y; Westwick, D T; Kearney, R E

    2011-11-01

    Joint stiffness, the dynamic relationship between the angular position of a joint and the torque acting about it, describes the dynamic, mechanical behavior of a joint during posture and movement. Joint stiffness arises from both intrinsic and reflex mechanisms, but the torques due to these mechanisms cannot be measured separately experimentally, since they appear and change together. Therefore, the direct estimation of the intrinsic and reflex stiffnesses is difficult. In this paper, we present a new, two-step procedure to estimate the intrinsic and reflex components of ankle stiffness. In the first step, a discrete-time, subspace-based method is used to estimate a state-space model for overall stiffness from the measured overall torque and then predict the intrinsic and reflex torques. In the second step, continuous-time models for the intrinsic and reflex stiffnesses are estimated from the predicted intrinsic and reflex torques. Simulations and experimental results demonstrate that the algorithm estimates the intrinsic and reflex stiffnesses accurately. The new subspace-based algorithm has three advantages over previous algorithms: 1) It does not require iteration, and therefore, will always converge to an optimal solution; 2) it provides better estimates for data with high noise or short sample lengths; and 3) it provides much more accurate results for data acquired under the closed-loop conditions, that prevail when subjects interact with compliant loads.

  18. Effect of static foot posture on the dynamic stiffness of foot joints during walking.

    PubMed

    Sanchis-Sales, E; Sancho-Bru, J L; Roda-Sales, A; Pascual-Huerta, J

    2018-05-01

    The static foot posture has been related to the development of lower limb injuries. This study aimed to investigate the dynamic stiffness of foot joints during gait in the sagittal plane to understand the role of the static foot posture in the development of injuries. Seventy healthy adult male subjects with different static postures, assessed by the Foot Posture Index (FPI) (30 normal, 20 highly pronated and 20 highly supinated), were recruited. Kinematic and kinetic data were recorded using an optical motion capture system and a pressure platform, and dynamic stiffness at the different stages of the stance was calculated from the slopes of the linear regression on the flexion moment-angle curves. The effect of foot type on dynamic stiffness and on ranges of motion and moments was analysed using ANOVAs and post-hoc tests, and linear correlation between dynamic stiffness and FPI was also tested. Highly pronated feet showed a significantly smaller range of motion at the ankle and metatarsophalangeal joints and also a larger range of moments at the metatarsophalangeal joint than highly supinated feet. Dynamic stiffness during propulsion was significantly greater at all foot joints for highly pronated feet, with positive significant correlations with the squared FPI. Highly supinated feet showed greater dynamic stiffness than normal feet, although to a lesser extent. Highly pronated feet during normal gait experienced the greatest decrease in the dorsiflexor moments during propulsion, normal feet being the most balanced regarding work generated and absorbed. Extreme static foot postures show greater dynamic stiffness during propulsion and greater absorbed work, which increases the risk of developing injuries. The data presented may be used when designing orthotics or prostheses, and also when planning surgery that modifies joint stiffness. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Management of the Stiff Finger: Evidence and Outcomes

    PubMed Central

    Yang, Guang; McGlinn, Evan P.; Chung, Kevin C.

    2014-01-01

    SYNOPSIS The term “stiff finger” refers to a reduction in the range of motion in the finger, and it is a condition that has many different causes and involves a number of different structures. Almost all injuries of the fingers and some diseases can cause finger stiffness. Hand surgeons often face difficulty treating stiff fingers that are affected by irreversible soft tissues fibrosis. Stiff fingers can be divided into flexion and extension deformities. They can also be sub-classified into four categories according to the involved tissues extending from the skin to the joint capsule. Prevention of stiff fingers by judicious mobilization of the joints is prudent to avoid more complicated treatment after established stiffness occurs. Static progressive and dynamic splints have been considered as effective non-operative interventions to treat stiff fingers. Most authors believe force of joint distraction and time duration of stretching are two important factors to consider while applying a splint or cast. We also introduce the concepts of capsulotomy and collateral ligament release and other soft tissue release of the MCP and PIP joint in this article. Future outcomes research is vital to assessing the effectiveness of these surgical procedures and guiding postoperative treatment recommendations. PMID:24996467

  20. An under-actuated origami gripper with adjustable stiffness joints for multiple grasp modes

    NASA Astrophysics Data System (ADS)

    Firouzeh, Amir; Paik, Jamie

    2017-05-01

    Under-actuated robots offer multiple degrees of freedom without much added complexity to the actuation and control. Utilizing adjustable stiffness joints in these robots allows us to control their stable configurations and their mode of interaction with the environment. In this paper, we present the design of tendon-driven robotic origami (robogami) joints with adjustable stiffness. The proposed designs allow us to place joints along any direction in the plane of the robot and in the normal direction to the plane. The layer-by-layer manufacturing of robogamis facilitates the design and manufacturing of robots with different arrangement of joints for different applications. We use thermally activated shape memory polymer to control the joint stiffness. The manufacturing of the polymer layer is compatible with the layer-by-layer manufacturing process of the robogamis which results in scalable and customizable robots. To demonstrate, we prototyped an under-actuated gripper with three fingers and only one input actuation. The grasp mode of the gripper is set by adjusting the configuration of the locked joints and modulating the stiffness of the active joints. We present a model to estimate the configuration and the contact forces of the gripper at different settings that will assist us in design and control of future generation of under-actuated robogamis.

  1. Muscle contributions to elbow joint rotational stiffness in preparation for sudden external arm perturbations.

    PubMed

    Holmes, Michael W R; Keir, Peter J

    2014-04-01

    Understanding joint stiffness and stability is beneficial for assessing injury risk. The purpose of this study was to examine joint rotational stiffness for individual muscles contributing to elbow joint stability. Fifteen male participants maintained combinations of three body orientations (standing, supine, sitting) and three hand preloads (no load, solid tube, fluid filled tube) while a device imposed a sudden elbow extension. Elbow angle and activity from nine muscles were inputs to a biomechanical model to determine relative contributions to elbow joint rotational stiffness, reported as percent of total stiffness. A body orientation by preload interaction was evident for most muscles (P<.001). Brachioradialis had the largest change in contribution while standing (no load, 18.5%; solid, 23.8%; fluid, 26.3%). Across trials, the greatest contributions were brachialis (30.4±1.9%) and brachioradialis (21.7±2.2%). Contributions from the forearm muscles and triceps were 5.5±0.6% and 9.2±1.9%, respectively. Contributions increased at time points closer to the perturbation (baseline to anticipatory), indicating increased neuromuscular response to resist rotation. This study quantified muscle contributions that resist elbow perturbations, found that forearm muscles contribute marginally and showed that orientation and preload should be considered when evaluating elbow joint stiffness and safety.

  2. Research regarding stiffness optimization of wires used for joints actuation from an elephant's trunk robotic arm

    NASA Astrophysics Data System (ADS)

    Ciofu, C.; Stan, G.

    2016-11-01

    Elephant's trunk robotic arms driven by wires and pulley mechanisms have issues with wires stiffness because of the entailed elastic deformations that is causing errors of positioning. Static and dynamic loads from each joint of the robotic arm affect the stiffness of driving wires and precision positioning. The influence of wires elastic deformation on precision positioning decreases with the increasing of wires stiffness by using different pre-tensioning devices. In this paper, we analyze the variation of driving wires stiffness particularly to each wire driven joint. We obtain optimum wires stiffness variation by using an analytical method that highlights the efficiency of pre-tensioning mechanism. The analysis of driving wires stiffness is necessary for taking appropriate optimization measures of robotic arm dynamic behavior and, thus, for decreasing positioning errors of the elephant's trunk robotic arm with inner actuation through wires/cables.

  3. Stretching of Active Muscle Elicits Chronic Changes in Multiple Strain Risk Factors.

    PubMed

    Kay, Anthony David; Richmond, Dominic; Talbot, Chris; Mina, Minas; Baross, Anthony William; Blazevich, Anthony John

    2016-07-01

    The muscle stretch intensity imposed during "flexibility" training influences the magnitude of joint range of motion (ROM) adaptation. Thus, stretching while the muscle is voluntarily activated was hypothesized to provide a greater stimulus than passive stretching. The effect of a 6-wk program of stretch imposed on an isometrically contracting muscle (i.e., qualitatively similar to isokinetic eccentric training) on muscle-tendon mechanics was therefore studied in 13 healthy human volunteers. Before and after the training program, dorsiflexion ROM, passive joint moment, and maximal isometric plantarflexor moment were recorded on an isokinetic dynamometer. Simultaneous real-time motion analysis and ultrasound imaging recorded gastrocnemius medialis muscle and Achilles tendon elongation. Training was performed twice weekly and consisted of five sets of 12 maximal isokinetic eccentric contractions at 10°·s. Significant increases (P < 0.01) in ROM (92.7% [14.7°]), peak passive moment (i.e., stretch tolerance; 136.2%), area under the passive moment curve (i.e., energy storage; 302.6%), and maximal isometric plantarflexor moment (51.3%) were observed after training. Although no change in the slope of the passive moment curve (muscle-tendon stiffness) was detected (-1.5%, P > 0.05), a significant increase in tendon stiffness (31.2%, P < 0.01) and a decrease in passive muscle stiffness (-14.6%, P < 0.05) were observed. The substantial positive adaptation in multiple functional and physiological variables that are cited within the primary etiology of muscle strain injury, including strength, ROM, muscle stiffness, and maximal energy storage, indicate that the stretching of active muscle might influence injury risk in addition to muscle function. The lack of change in muscle-tendon stiffness simultaneous with significant increases in tendon stiffness and decreases in passive muscle stiffness indicates that tissue-specific effects were elicited.

  4. Comparison of neuromuscular abnormalities between upper and lower extremities in hemiparetic stroke.

    PubMed

    Mirbagheri, M M; AliBiglou, L; Thajchayapong, M; Lilaonitkul, T; Rymer, W Z

    2006-01-01

    We studied the neuromuscular mechanical properties of the elbow and ankle joints in chronic, hemiparetic stroke patients and healthy subjects. System identification techniques were used to characterize the mechanical abnormalities of these joints and to identify the contribution of intrinsic and reflex stiffness to these abnormalities. Modulation of intrinsic and reflex stiffness with the joint angle was studied by applying PRBS perturbations to the joint at different joint angles. The experiments were performed for both spastic (stroke) and contralateral (control) sides of stroke patients and one side of healthy (normal) subjects. We found reflex stiffness gain (GR) was significantly larger in the stroke than the control side for both elbow and ankle joints. GR was also strongly position dependent in both joints. However, the modulation of GR with position was slightly different in two joints. GR was also larger in the control than the normal joints but the differences were significant only for the ankle joint. Intrinsic stiffness gain (K) was also significantly larger in the stroke than the control joint at elbow extended positions and at ankle dorsiflexed positions. Modulation of K with the ankle angle was similar for stroke, control and normal groups. In contrast, the position dependency of the elbow was different. K was larger in the control than normal ankle whereas it was lower in the control than normal elbow. However, the differences were not significant for any joint. The findings demonstrate that both reflex and intrinsic stiffness gain increase abnormally in both upper and lower extremities. However, the major contribution of intrinsic and reflex stiffness to the abnormalities is at the end of ROM and at the middle ROM, respectively. The results also demonstrate that the neuromuscular properties of the contralateral limb are not normal suggesting that it may not be used as a suitable control at least for the ankle study.

  5. Comparison of cervical spine stiffness in individuals with chronic nonspecific neck pain and asymptomatic individuals.

    PubMed

    Ingram, Lewis A; Snodgrass, Suzanne J; Rivett, Darren A

    2015-03-01

    Clinical measurement, cross-sectional. To determine if spinal joint stiffness is different in individuals with nonspecific neck pain, and whether stiffness magnitude is associated with pain intensity and disability. Manual therapists commonly evaluate spinal joint stiffness in patients presenting with nonspecific neck pain. However, a relationship between stiffness and neck pain has not yet been demonstrated. Spinal stiffness at C7 was objectively measured in participants with chronic nonspecific neck pain whose symptomatic spinal level was identified as C7 (n = 12) and in age- and sex-matched asymptomatic controls (n = 12). Stiffness (slope of the linear region of the force-displacement curve) was quantified using a device that applied 5 standardized mechanical force cycles to the C7 spinous process, while concurrently measuring displacement and resistance to movement. Stiffness was compared between groups using an independent t test. Spearman rho and Pearson r were used to determine the extent to which stiffness magnitude was associated with pain intensity (visual analog scale) and level of disability (Neck Disability Index), respectively, in the group with neck pain. Participants with nonspecific neck pain had greater spinal joint stiffness at C7 compared with asymptomatic individuals (mean difference, 1.78 N/mm; 95% confidence interval: 0.28, 3.27; P = .022). However, stiffness magnitude in the group with neck pain was not associated (P>.05) with pain intensity or level of disability. These preliminary results suggest that cervical spine stiffness may be greater in the presence of nonspecific neck pain. However, judgments regarding pain intensity and level of disability should not be inferred from examinations of spinal joint stiffness.

  6. Determination of Ankle and Metatarsophalangeal Stiffness During Walking and Jogging.

    PubMed

    Mager, Fabian; Richards, Jim; Hennies, Malika; Dötzel, Eugen; Chohan, Ambreen; Mbuli, Alex; Capanni, Felix

    2018-05-29

    Forefoot stiffness has been shown to influence joint biomechanics. However, little or no data exists on metatarsophalangeal stiffness. Twenty-four healthy rearfoot strike runners were recruited from a staff and student population at the University of Central Lancashire. Five repetitions of shod, self-selected speed level walking and jogging were performed. Kinetic and kinematic data were collected using retro-reflective markers placed on the lower limb and foot, to create a three-segment foot model using the Calibrated Anatomical System Technique. Ankle and metatarsophalangeal moments and angles were calculated. Stiffness values were calculated using a linear best fit line of moment versus of angle plots. Paired t-tests were used to compare values between walking and jogging conditions. Significant differences were seen in ankle range of motion (ROM), but not in metatarsophalangeal ROM. Maximum moments were significantly greater in the ankle during jogging, but these were not significantly different at the metatarsophalangeal joint. Average ankle joint stiffness exhibited significantly lower stiffness when walking compared to jogging. However, the metatarsophalangeal joint exhibited significantly greater stiffness when walking compared to jogging. A greater understanding of forefoot stiffness may inform the development of footwear, prosthetic feet and orthotic devices, such as ankle-foot orthoses for walking and sporting activities.

  7. Lower Body Stiffness Modulation Strategies in Well Trained Female Athletes.

    PubMed

    Millett, Emma L; Moresi, Mark P; Watsford, Mark L; Taylor, Paul G; Greene, David A

    2016-10-01

    Millett, EL, Moresi, MP, Watsford, ML, Taylor, PG, and Greene, DA. Lower body stiffness modulation strategies in well trained female athletes. J Strength Cond Res 30(10): 2845-2856, 2016-Lower extremity stiffness quantifies the relationship between the amount of leg compression and the external load to which the limb are subjected. This study aimed to assess differences in leg and joint stiffness and the subsequent kinematic and kinetic control mechanisms between athletes from various training backgrounds. Forty-seven female participants (20 nationally identified netballers, 13 high level endurance athletes and 14 age and gender matched controls) completed a maximal unilateral countermovement jump, drop jump and horizontal jump to assess stiffness. Leg stiffness, joint stiffness and associated mechanical parameters were assessed with a 10 camera motion analysis system and force plate. No significant differences were evident for leg stiffness measures between athletic groups for any of the tasks (p = 0.321-0.849). However, differences in joint stiffness and its contribution to leg stiffness, jump performance outcome measures and stiffness control mechanisms were evident between all groups. Practitioners should consider the appropriateness of the task utilised in leg stiffness screening. Inclusion of mechanistic and/or more sports specific tasks may be more appropriate for athletic groups.

  8. Knee joint laxity and passive stiffness in meniscectomized patients compared with healthy controls.

    PubMed

    Thorlund, Jonas B; Creaby, Mark W; Wrigley, Tim V; Metcalf, Ben R; Bennell, Kim L

    2014-10-01

    Passive mechanical behavior of the knee in the frontal plane, measured as angular laxity and mechanical stiffness, may play an important role in the pathogenesis of knee osteoarthritis (OA). Little is known about knee laxity and stiffness prior to knee OA onset. We investigated knee joint angular laxity and passive stiffness in meniscectomized patients at high risk of knee OA compared with healthy controls. Sixty patients meniscectomized for a medial meniscal tear (52 men, 41.4 ± 5.5 years, 175.3 ± 7.9 cm, 83.6 ± 12.8 kg, mean ± SD) and 21 healthy controls (18 men, 42.0 ± 6.7 years, 176.8 ± 5.7 cm, 77.8 ± 13.4 kg) had their knee joint angular laxity and passive stiffness assessed twice ~2.3 years apart. Linear regression models including age, sex, height and body mass as covariates in the adjusted model were used to assess differences between groups. Greater knee joint varus (-10.1 vs. -7.3°, p<0.001), valgus (7.1 vs. 5.6°, p=0.001) and total (17.2 vs. 12.9°, p<0.001) angular laxity together with reduced midrange passive stiffness (1.71 vs. 2.36 Nm/°, p<0.001) were observed in patients vs. healthy controls. No differences were observed in change in stiffness over time between patients and controls, however a tendency towards increased laxity in patients was seen. Meniscectomized patients showed increased knee joint angular laxity and reduced passive stiffness ~3 months post surgery compared with controls. In addition, the results indicated that knee joint laxity may increase over time in meniscectomized patients. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Human arm stiffness and equilibrium-point trajectory during multi-joint movement.

    PubMed

    Gomi, H; Kawato, M

    1997-03-01

    By using a newly designed high-performance manipulandum and a new estimation algorithm, we measured human multi-joint arm stiffness parameters during multi-joint point-to-point movements on a horizontal plane. This manipulandum allows us to apply a sufficient perturbation to subject's arm within a brief period during movement. Arm stiffness parameters were reliably estimated using a new algorithm, in which all unknown structural parameters could be estimated independent of arm posture (i.e., constant values under any arm posture). Arm stiffness during transverse movement was considerably greater than that during corresponding posture, but not during a longitudinal movement. Although the ratios of elbow, shoulder, and double-joint stiffness were varied in time, the orientation of stiffness ellipses during the movement did not change much. Equilibrium-point trajectories that were predicted from measured stiffness parameters and actual trajectories were slightly sinusoidally curved in Cartesian space and their velocity profiles were quite different from the velocity profiles of actual hand trajectories. This result contradicts the hypothesis that the brain does not take the dynamics into account in movement control depending on the neuromuscular servo mechanism; rather, it implies that the brain needs to acquire some internal models of controlled objects.

  10. Interlimb symmetry of dynamic knee joint stiffness and co-contraction is maintained in early stage knee osteoarthritis.

    PubMed

    Collins, A T; Richardson, R T; Higginson, J S

    2014-08-01

    Individuals with knee OA often exhibit greater co-contraction of antagonistic muscle groups surrounding the affected joint which may lead to increases in dynamic joint stiffness. These detrimental changes in the symptomatic limb may also exist in the contralateral limb, thus contributing to its risk of developing knee osteoarthritis. The purpose of this study is to investigate the interlimb symmetry of dynamic knee joint stiffness and muscular co-contraction in knee osteoarthritis. Muscular co-contraction and dynamic knee joint stiffness were assessed in 17 subjects with mild to moderate unilateral medial compartment knee osteoarthritis and 17 healthy control subjects while walking at a controlled speed (1.0m/s). Paired and independent t-tests determined whether significant differences exist between groups (p<0.05). There were no significant differences in dynamic joint stiffness or co-contraction between the OA symptomatic and OA contralateral group (p=0.247, p=0.874, respectively) or between the OA contralateral and healthy group (p=0.635, p=0.078, respectively). There was no significant difference in stiffness between the OA symptomatic and healthy group (p=0.600); however, there was a slight trend toward enhanced co-contraction in the symptomatic knees compared to the healthy group (p=0.051). Subjects with mild to moderate knee osteoarthritis maintain symmetric control strategies during gait. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Interlimb symmetry of dynamic knee joint stiffness and co-contraction is maintained in early stage knee osteoarthritis

    PubMed Central

    Collins, A.T.; Richardson, R.T.; Higginson, J.S.

    2014-01-01

    Individuals with knee OA often exhibit greater co-contraction of antagonistic muscle groups surrounding the affected joint which may lead to increases in dynamic joint stiffness. These detrimental changes in the symptomatic limb may also exist in the contralateral limb, thus contributing to its risk of developing knee osteoarthritis. The purpose of this study is to investigate the interlimb symmetry of dynamic knee joint stiffness and muscular co-contraction in knee osteoarthritis. Muscular co-contraction and dynamic knee joint stiffness were assessed in 17 subjects with mild to moderate unilateral medial compartment knee osteoarthritis and 17 healthy control subjects while walking at a controlled speed (1.0 m/s). Paired and independent t-tests determined whether significant differences exist between groups (p < 0.05). There were no significant differences in dynamic joint stiffness or co-contraction between the OA symptomatic and OA contralateral group (p = 0.247, p = 0.874, respectively) or between the OA contralateral and healthy group (p = 0.635, p = 0.078, respectively). There was no significant difference in stiffness between the OA symptomatic and healthy group (p = 0.600); however, there was a slight trend toward enhanced co-contraction in the symptomatic knees compared to the healthy group (p = 0.051). Subjects with mild to moderate knee osteoarthritis maintain symmetric control strategies during gait. PMID:24768278

  12. Biomechanics of an orthosis-managed cranial cruciate ligament-deficient canine stifle joint predicted by use of a computer model.

    PubMed

    Bertocci, Gina E; Brown, Nathan P; Mich, Patrice M

    2017-01-01

    OBJECTIVE To evaluate effects of an orthosis on biomechanics of a cranial cruciate ligament (CrCL)-deficient canine stifle joint by use of a 3-D quasistatic rigid-body pelvic limb computer model simulating the stance phase of gait and to investigate influences of orthosis hinge stiffness (durometer). SAMPLE A previously developed computer simulation model for a healthy 33-kg 5-year-old neutered Golden Retriever. PROCEDURES A custom stifle joint orthosis was implemented in the CrCL-deficient pelvic limb computer simulation model. Ligament loads, relative tibial translation, and relative tibial rotation in the orthosis-stabilized stifle joint (baseline scenario; high-durometer hinge]) were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. Sensitivity analysis was conducted to evaluate the influence of orthosis hinge stiffness on model outcome measures. RESULTS The orthosis decreased loads placed on the caudal cruciate and lateral collateral ligaments and increased load placed on the medial collateral ligament, compared with loads for the CrCL-intact stifle joint. Ligament loads were decreased in the orthosis-managed CrCL-deficient stifle joint, compared with loads for the CrCL-deficient stifle joint. Relative tibial translation and rotation decreased but were not eliminated after orthosis management. Increased orthosis hinge stiffness reduced tibial translation and rotation, whereas decreased hinge stiffness increased internal tibial rotation, compared with values for the baseline scenario. CONCLUSIONS AND CLINICAL RELEVANCE Stifle joint biomechanics were improved following orthosis implementation, compared with biomechanics of the CrCL-deficient stifle joint. Orthosis hinge stiffness influenced stifle joint biomechanics. An orthosis may be a viable option to stabilize a CrCL-deficient canine stifle joint.

  13. Force control compensation method with variable load stiffness and damping of the hydraulic drive unit force control system

    NASA Astrophysics Data System (ADS)

    Kong, Xiangdong; Ba, Kaixian; Yu, Bin; Cao, Yuan; Zhu, Qixin; Zhao, Hualong

    2016-05-01

    Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit (HDU), and the contacting between the robot foot end and the ground is complex and variable, which increases the difficulty of force control inevitably. In the recent years, although many scholars researched some control methods such as disturbance rejection control, parameter self-adaptive control, impedance control and so on, to improve the force control performance of HDU, the robustness of the force control still needs improving. Therefore, how to simulate the complex and variable load characteristics of the environment structure and how to ensure HDU having excellent force control performance with the complex and variable load characteristics are key issues to be solved in this paper. The force control system mathematic model of HDU is established by the mechanism modeling method, and the theoretical models of a novel force control compensation method and a load characteristics simulation method under different environment structures are derived, considering the dynamic characteristics of the load stiffness and the load damping under different environment structures. Then, simulation effects of the variable load stiffness and load damping under the step and sinusoidal load force are analyzed experimentally on the HDU force control performance test platform, which provides the foundation for the force control compensation experiment research. In addition, the optimized PID control parameters are designed to make the HDU have better force control performance with suitable load stiffness and load damping, under which the force control compensation method is introduced, and the robustness of the force control system with several constant load characteristics and the variable load characteristics respectively are comparatively analyzed by experiment. The research results indicate that if the load characteristics are known, the force control compensation method presented in this paper has positive compensation effects on the load characteristics variation, i.e., this method decreases the effects of the load characteristics variation on the force control performance and enhances the force control system robustness with the constant PID parameters, thereby, the online PID parameters tuning control method which is complex needs not be adopted. All the above research provides theoretical and experimental foundation for the force control method of the quadruped robot joints with high robustness.

  14. Influence of Joint Flexibility on Vibration Analysis of Free-Free Beams

    NASA Astrophysics Data System (ADS)

    Gunda, Jagadish Babu; Krishna, Y.

    2014-12-01

    In present work, joint flexibility (or looseness) of the free-free beam is investigated by using a two noded beam finite element formulation with transverse displacement and joint rotations as the degrees of freedom per node at joint location. Flexibility of the joint is primarily represented by means of a rotational spring analogy, where the stiffness of the rotational spring characterizes the looseness of the flexible joint for an applied bending moment. Influence of joint location as well as joint stiffness on modal behavior of first five modes of slender, uniform free-free beams are discussed for various values of non-dimensional rotational spring stiffness parameter. Numerical accuracy of the results obtained from the present finite element formulation are validated by using the commercially available finite element software which shows the confidence gained on the numerical results discussed in the present study.

  15. Soft tissue balance changes depending on joint distraction force in total knee arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Matsumoto, Tomoyuki; Miya, Hidetoshi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2014-03-01

    The influence of joint distraction force on intraoperative soft tissue balance was evaluated using Offset Repo-Tensor® for 78 knees that underwent primary posterior-stabilized total knee arthroplasty. The joint center gap and varus ligament balance were measured between osteotomized surfaces using 20, 40 and 60 lbs of joint distraction force. These values were significantly increased at extension and flexion as the distraction force increased. Furthermore, lateral compartment stiffness was significantly lower than medial compartment stiffness. Thus, larger joint distraction forces led to larger varus ligament balance and joint center gap, because of the difference in soft tissue stiffness between lateral and medial compartments. These findings indicate the importance of the strength of joint distraction force in the assessment of soft tissue balance, especially when using gap-balancing technique. © 2014.

  16. Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair.

    PubMed

    Weiser, Lukas; Nüchtern, Jakob V; Sellenschloh, Kay; Püschel, Klaus; Morlock, Michael M; Rueger, Johannes M; Hoffmann, Michael; Lehmann, Wolfgang; Großterlinden, Lars G

    2017-07-01

    To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing. Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.

  17. External rotation elastic bands at the lower limb decrease rearfoot eversion during walking: a preliminary proof of concept

    PubMed Central

    Souza, Thales R.; Araújo, Vanessa L.; Silva, Paula L.; Carvalhais, Viviane O. C.; Resende, Renan A.; Fonseca, Sérgio T.

    2016-01-01

    ABSTRACT Background Reducing rearfoot eversion is a commonly desired effect in clinical practice to prevent or treat musculoskeletal dysfunction. Interventions that pull the lower limb into external rotation may reduce rearfoot eversion. Objective This study investigated whether the use of external rotation elastic bands, of different levels of stiffness, will decrease rearfoot eversion during walking. We hypothesized that the use of elastic bands would decrease rearfoot eversion and that the greater the band stiffness, the greater the eversion reduction. Method Seventeen healthy participants underwent three-dimensional kinematic analysis of the rearfoot and shank. The participants walked on a treadmill with and without high- and low-stiffness bands. Frontal-plane kinematics of the rearfoot-shank joint complex was obtained during the stance phase of walking. Repeated-measures ANOVAs were used to compare discrete variables that described rearfoot eversion-inversion: mean eversion-inversion; eversion peak; and eversion-inversion range of motion. Results The low-stiffness and high-stiffness bands significantly decreased eversion and increased mean eversion-inversion (p≤0.037) and eversion peak (p≤0.006) compared with the control condition. Both bands also decreased eversion-inversion range of motion (p≤0.047) compared with control by reducing eversion. The high-stiffness band condition was not significantly different from the low-stiffness band condition for any variables (p≥0.479). Conclusion The results indicated that the external rotation bands decreased rearfoot eversion during walking. This constitutes preliminary experimental evidence suggesting that increasing external rotation moments at the lower limb may reduce rearfoot eversion, which needs further testing. PMID:27849289

  18. Knee Kinematics Estimation Using Multi-Body Optimisation Embedding a Knee Joint Stiffness Matrix: A Feasibility Study.

    PubMed

    Richard, Vincent; Lamberto, Giuliano; Lu, Tung-Wu; Cappozzo, Aurelio; Dumas, Raphaël

    2016-01-01

    The use of multi-body optimisation (MBO) to estimate joint kinematics from stereophotogrammetric data while compensating for soft tissue artefact is still open to debate. Presently used joint models embedded in MBO, such as mechanical linkages, constitute a considerable simplification of joint function, preventing a detailed understanding of it. The present study proposes a knee joint model where femur and tibia are represented as rigid bodies connected through an elastic element the behaviour of which is described by a single stiffness matrix. The deformation energy, computed from the stiffness matrix and joint angles and displacements, is minimised within the MBO. Implemented as a "soft" constraint using a penalty-based method, this elastic joint description challenges the strictness of "hard" constraints. In this study, estimates of knee kinematics obtained using MBO embedding four different knee joint models (i.e., no constraints, spherical joint, parallel mechanism, and elastic joint) were compared against reference kinematics measured using bi-planar fluoroscopy on two healthy subjects ascending stairs. Bland-Altman analysis and sensitivity analysis investigating the influence of variations in the stiffness matrix terms on the estimated kinematics substantiate the conclusions. The difference between the reference knee joint angles and displacements and the corresponding estimates obtained using MBO embedding the stiffness matrix showed an average bias and standard deviation for kinematics of 0.9±3.2° and 1.6±2.3 mm. These values were lower than when no joint constraints (1.1±3.8°, 2.4±4.1 mm) or a parallel mechanism (7.7±3.6°, 1.6±1.7 mm) were used and were comparable to the values obtained with a spherical joint (1.0±3.2°, 1.3±1.9 mm). The study demonstrated the feasibility of substituting an elastic joint for more classic joint constraints in MBO.

  19. Knee Kinematics Estimation Using Multi-Body Optimisation Embedding a Knee Joint Stiffness Matrix: A Feasibility Study

    PubMed Central

    Richard, Vincent; Lamberto, Giuliano; Lu, Tung-Wu; Cappozzo, Aurelio; Dumas, Raphaël

    2016-01-01

    The use of multi-body optimisation (MBO) to estimate joint kinematics from stereophotogrammetric data while compensating for soft tissue artefact is still open to debate. Presently used joint models embedded in MBO, such as mechanical linkages, constitute a considerable simplification of joint function, preventing a detailed understanding of it. The present study proposes a knee joint model where femur and tibia are represented as rigid bodies connected through an elastic element the behaviour of which is described by a single stiffness matrix. The deformation energy, computed from the stiffness matrix and joint angles and displacements, is minimised within the MBO. Implemented as a “soft” constraint using a penalty-based method, this elastic joint description challenges the strictness of “hard” constraints. In this study, estimates of knee kinematics obtained using MBO embedding four different knee joint models (i.e., no constraints, spherical joint, parallel mechanism, and elastic joint) were compared against reference kinematics measured using bi-planar fluoroscopy on two healthy subjects ascending stairs. Bland-Altman analysis and sensitivity analysis investigating the influence of variations in the stiffness matrix terms on the estimated kinematics substantiate the conclusions. The difference between the reference knee joint angles and displacements and the corresponding estimates obtained using MBO embedding the stiffness matrix showed an average bias and standard deviation for kinematics of 0.9±3.2° and 1.6±2.3 mm. These values were lower than when no joint constraints (1.1±3.8°, 2.4±4.1 mm) or a parallel mechanism (7.7±3.6°, 1.6±1.7 mm) were used and were comparable to the values obtained with a spherical joint (1.0±3.2°, 1.3±1.9 mm). The study demonstrated the feasibility of substituting an elastic joint for more classic joint constraints in MBO. PMID:27314586

  20. Effects of circumferential ankle pressure on ankle proprioception, stiffness, and postural stability: a preliminary investigation.

    PubMed

    You, Sung H; Granata, Kevin P; Bunker, Linda K

    2004-08-01

    Cross-sectional repeated-measures design. Determine the effects of circumferential ankle pressure (CAP) intervention on proprioceptive acuity, ankle stiffness, and postural stability. The application of CAP using braces, taping, and adaptive shoes or military boots is widely used to address chronic ankle instability (CAI). An underlying assumption is that the CAP intervention might improve ankle stability through increased proprioceptive acuity and stiffness in the ankle. METHOD AND MEASURES: A convenience sample of 10 subjects was recruited from the local university community and categorized according to proprioceptive acuity (high, low) and ankle stability (normal, CAI). Proprioceptive acuity was measured when blindfolded subjects were asked to accurately reproduce a self-selected target ankle position before and after the application of CAP. Proprioceptive acuity was determined in 5 different ankle joint position sense tests: neutral, inversion, eversion, plantar flexion, and dorsiflexion. Joint position angles were recorded electromechanically using a potentiometer. Passive ankle stiffness was computed from the ratio of applied static moment versus angular displacement. Active ankle stiffness was determined from biomechanical analyses of ankle motion following a mediolateral perturbation. Postural stability was quantified from the center of pressure displacement in the mediolateral and the anteroposterior directions in unipedal stance. All measurements were recorded with and without CAP applied by a pediatric blood pressure cuff. Data were analyzed using a separate mixed-model analysis of variance (ANOVA) for each dependent variable. Post hoc comparison using Tukey's honestly significant difference (HSD) test was performed if significant interactions were obtained. Significance level was set at P<.05 for all analyses. Significant group (high versus low proprioceptive acuity) x CAP interactions were identified for postural stability. Passive ankle stiffness was not increased by an application of CAP. Active ankle stiffness was significantly different between the high and low proprioceptive acuity groups and was not affected by an application of CAP. Significant group (normal versus CAI) x CAP interactions were observed for mediolateral center-of-pressure displacement with a main effect of group on neutral joint position sense. Application of CAP increased proprioceptive acuity and demonstrated trends toward increased active stiffness in the ankle, hence improved postural stability. The effects tend to be limited to individuals with low proprioceptive acuity.

  1. Lower Extremity Stiffness Changes after Concussion in Collegiate Football Players.

    PubMed

    Dubose, Dominique F; Herman, Daniel C; Jones, Deborah L; Tillman, Susan M; Clugston, James R; Pass, Anthony; Hernandez, Jorge A; Vasilopoulos, Terrie; Horodyski, Marybeth; Chmielewski, Terese L

    2017-01-01

    Recent research indicates that a concussion increases the risk of musculoskeletal injury. Neuromuscular changes after concussion might contribute to the increased risk of injury. Many studies have examined gait postconcussion, but few studies have examined more demanding tasks. This study compared changes in stiffness across the lower extremity, a measure of neuromuscular function, during a jump-landing task in athletes with a concussion (CONC) to uninjured athletes (UNINJ). Division I football players (13 CONC and 26 UNINJ) were tested pre- and postseason. A motion capture system recorded subjects jumping on one limb from a 25.4-cm step onto a force plate. Hip, knee, and ankle joint stiffness were calculated from initial contact to peak joint flexion using the regression line slopes of the joint moment versus the joint angle plots. Leg stiffness was (peak vertical ground reaction force [PVGRF]/lower extremity vertical displacement) from initial contact to peak vertical ground reaction force. All stiffness values were normalized to body weight. Values from both limbs were averaged. General linear models compared group (CONC, UNINJ) differences in the changes of pre- and postseason stiffness values. Average time from concussion to postseason testing was 49.9 d. The CONC group showed an increase in hip stiffness (P = 0.03), a decrease in knee (P = 0.03) and leg stiffness (P = 0.03), but no change in ankle stiffness (P = 0.65) from pre- to postseason. Lower extremity stiffness is altered after concussion, which could contribute to an increased risk of lower extremity injury. These data provide further evidence of altered neuromuscular function after concussion.

  2. Lower Extremity Stiffness Changes following Concussion in Collegiate Football Players

    PubMed Central

    DuBose, Dominique F.; Herman, Daniel C.; Jones, Debi L.; Tillman, Susan M.; Clugston, James R.; Pass, Anthony; Hernandez, Jorge A.; Vasilopoulos, Terrie; Horodyski, MaryBeth; Chmielewski, Terese L.

    2016-01-01

    Purpose Recent research indicates that a concussion increases risk of musculoskeletal injury. Neuromuscular changes following concussion might contribute to the increased risk of injury. Many studies have examined gait post-concussion, but few studies have examined more demanding tasks. This study compared changes in stiffness across the lower extremity, a measure of neuromuscular function, during a jump-landing task in athletes with a concussion (CONC) to uninjured athletes (UNINJ). Methods Division I football players (13 CONC, 26 UNINJ) were tested pre- and post-season. A motion-capture system recorded subjects jumping on one limb from a 25.4 cm step onto a force plate. Hip, knee, and ankle joint stiffness were calculated from initial contact to peak joint flexion using the regression line slopes of the joint moment versus joint angle plots. Leg stiffness was (peak vertical ground reaction force (PVGRF)/lower extremity vertical displacement) from initial contact to PVGRF. All stiffness values were normalized to bodyweight. Values from both limbs were averaged. General linear models compared group (CONC, UNINJ) differences in the changes of pre- and post-season stiffness values. Results Average time from concussion to post-season testing was 49.9 days. The CONC group showed an increase in hip stiffness (p=0.03), a decrease in knee (p=0.03) and leg stiffness (p=0.03), but no change in ankle stiffness (p=0.65) from pre- to post-season. Conclusion Lower extremity stiffness is altered following concussion, which could contribute to an increased risk of lower extremity injury. These data provide further evidence of altered neuromuscular function after concussion. PMID:27501359

  3. Independent control of joint stiffness in the framework of the equilibrium-point hypothesis.

    PubMed

    Latash, M L

    1992-01-01

    In the framework of the equilibrium-point hypothesis, virtual trajectories and joint stiffness patterns have been reconstructed during two motor tasks practiced against a constant bias torque. One task required a voluntary increase in joint stiffness while preserving the original joint position. The other task involved fast elbow flexions over 36 degrees. Joint stiffness gradually subsided after the termination of fast movements. In both tasks, the external torque could slowly and unexpectedly change. The subjects were required not to change their motor commands if the torque changed, i.e. "to do the same no matter what the motor did". In both tasks, changes in joint stiffness were accompanied by unchanged virtual trajectories that were also independent of the absolute value of the bias torque. By contrast, the intercept of the joint compliant characteristic with the angle axis, r(t)-function, has demonstrated a clear dependence upon both the level of coactivation and external load. We assume that a template virtual trajectory is generated at a certain level of the motor hierarchy and is later scaled taking into account some commonly changing dynamic factors of the movement execution, for example, external load. The scaling leads to the generation of commands to the segmental structures that can be expressed, according to the equilibrium-point hypothesis, as changes in the thresholds of the tonic stretch reflex for corresponding muscles.

  4. A randomised controlled trial of intra-articular corticosteroid injection of the carpometacarpal joint of the thumb in osteoarthritis

    PubMed Central

    Meenagh, G; Patton, J; Kynes, C; Wright, G

    2004-01-01

    Objective: To investigate the efficacy of corticosteroid injections into the carpometacarpal joint of the thumb (CMCJ) in patients with osteoarthritis. Design: A double blind, randomised controlled trial using 40 hospital referred patients with CMCJ osteoarthritis who received intra-articular injections of 5 mg triamcinolone hexacetonide (0.25 ml) or sterile 0.9% saline (0.25 ml). Injections were given under imaging control. Main outcome measures: The primary outcome was improvement in a pain visual analogue score (VAS) of 20% at 24 weeks. In addition patients were assessed at 4, 12, and 24 weeks for joint stiffness, joint tenderness, and physician and patient global assessments. Hand radiographs were evaluated for the degree of CMC joint space narrowing and marginal osteophytes according to the OARSI atlas. Results: Baseline clinical variables were not significantly different between the two treatment groups. There was no improvement in the VAS of pain at 24 weeks. At each assessment point there was no significant difference between the steroid and placebo groups in median values for joint stiffness, joint tenderness, or patient and physician global assessments. Non-parametric analysis of each group individually revealed statistically significant improvements in patient and physician global assessments at weeks 4, 12, and 24 in the placebo group and at weeks 4 and 12 in the steroid group. Conclusions: No clinical benefit was gained from intra-articular steroid injection to the CMCJ in moderate to severe osteoarthritis compared with placebo injection. PMID:15361383

  5. Performance Analysis of a Self-Propelling Flat Plate Fin with Joint Compliance

    NASA Astrophysics Data System (ADS)

    Reddy, N. Srinivasa; Sen, Soumen; Pal, Sumit; Shome, Sankar Nath

    2017-12-01

    Fish fin muscles are compliant and they regulate the stiffness to suit different swimming conditions. This article attempts to understand the significance of presence of compliance in fin muscle with help of a flexible joint flat plate fin model. Blade element method is employed to model hydrodynamics and to compute the forces of interaction during motion of the plate within fluid. The dynamic model of self-propelling fin is developed through multi-body dynamics approach considering the hydrodynamic forces as external forces acting on the fin. The derived hydrodynamic model is validated with experiments on rigid flat plate fin. The effect of the joint stiffness and flapping frequency on the propulsion speed and efficiency is investigated through simulations using the derived and validated model. The propulsion efficiency is found to be highly influenced by the joint stiffness at a given flapping frequency. The fin attained maximum propulsion efficiency when the joint stiffness is tuned to a value at which flapping frequency matches near natural frequency of the fin. At this tuned joint stiffness and flapping frequency, the resulted Strouhal numbers are observed to fall within the optimum range (0.2 to 0.4) for maximized propulsion efficiency of flying birds and swimming aquatic animals reported in literature.

  6. Gait training reduces ankle joint stiffness and facilitates heel strike in children with Cerebral Palsy.

    PubMed

    Willerslev-Olsen, Maria; Lorentzen, Jakob; Nielsen, Jens Bo

    2014-01-01

    Foot drop and toe walking are frequent concerns in children with cerebral palsy (CP). Increased stiffness of the ankle joint muscles may contribute to these problems. Does four weeks of daily home based treadmill training with incline reduce ankle joint stiffness and facilitate heel strike in children with CP? Seventeen children with CP (4-14 years) were recruited. Muscle stiffness and gait ability were measured twice before and twice after training with an interval of one month. Passive and reflex-mediated stiffness were measured by a dynamometer which applied stretches below and above reflex threshold. Gait kinematics were recorded by 3-D video-analysis during treadmill walking. Foot pressure was measured by force-sensitive foot soles during treadmill and over-ground walking. Children with increased passive stiffness showed a significant reduction in stiffness following training (P = 0.01). Toe lift in the swing phase (P = 0.014) and heel impact (P = 0.003) increased significantly following the training during both treadmill and over-ground walking. Daily intensive gait training may influence the elastic properties of ankle joint muscles and facilitate toe lift and heel strike in children with CP. Intensive gait training may be beneficial in preventing contractures and maintain gait ability in children with CP.

  7. A quasi-linear control theory analysis of timesharing skills

    NASA Technical Reports Server (NTRS)

    Agarwal, G. C.; Gottlieb, G. L.

    1977-01-01

    The compliance of the human ankle joint is measured by applying 0 to 50 Hz band-limited gaussian random torques to the foot of a seated human subject. These torques rotate the foot in a plantar-dorsal direction about a horizontal axis at a medial moleolus of the ankle. The applied torques and the resulting angular rotation of the foot are measured, digitized and recorded for off-line processing. Using such a best-fit, second-order model, the effective moment of inertia of the ankle joint, the angular viscosity and the stiffness are calculated. The ankle joint stiffness is shown to be a linear function of the level of tonic muscle contraction, increasing at a rate of 20 to 40 Nm/rad/Kg.m. of active torque. In terms of the muscle physiology, the more muscle fibers that are active, the greater the muscle stiffness. Joint viscosity also increases with activation. Joint stiffness is also a linear function of the joint angle, increasing at a rate of about 0.7 to 1.1 Nm/rad/deg from plantar flexion to dorsiflexion rotation.

  8. The differential effects of gender, anthropometry, and prior hormonal state on frontal plane knee joint stiffness

    PubMed Central

    Cammarata, Martha L.; Dhaher, Yasin Y.

    2012-01-01

    Background Gender differences in passive frontal plane knee stiffness may contribute to the increased anterior cruciate ligament injury rate in females. Gender-based stiffness differences have been attributed to anthropometric variations, but little data exist describing this relationship. Furthermore, sex hormone levels appear to influence joint stiffness, but the differential effects of instantaneous and prior hormonal concentrations remain unknown. This study sought to explore the effect of gender, prior hormonal status, and anthropometry on passive frontal plane knee joint stiffness. Methods Twelve males and 31 females participated. Females were grouped by hormonal contraceptive use (non users [n=11], monophasic contraceptive users [n=11], and triphasic contraceptive users [n=9]) and tested at the same point in the menstrual cycle. Subjects’ right knee was passively stretched ±7° in the frontal plane at 3°/s. Stiffness was estimated at three loading levels and normalized by body size to minimize anthropometric biases. A 4 (group) × 3 (load) repeated measures analysis of variance was performed for both raw and normalized stiffness. Linear regression analyses were preformed between stiffness estimates and knee diameter and quadriceps femoris angle. Findings Males displayed significantly greater (P<0.05) frontal plane stiffness than females. When normalized, males displayed significantly greater stiffness in valgus (P<0.05), but not varus (P>0.05) than females. No significant effect (P>0.05) of prior hormonal state was found; however, when normalized, varus stiffness was significantly less for triphasic contraceptive users than the other female groups (P<0.05). Quadriceps femoris angle was negatively correlated and knee diameter was positively correlated to knee stiffness. Interpretation Consistent with earlier in vitro findings, our data may indicate that ligament material properties are gender specific. A deficit in passive knee joint stiffness may place a larger burden on the neuromuscular system to resist frontal plane loading in females. PMID:18479791

  9. Arch structure is associated with unique joint work, relative joint contributions and stiffness during landing.

    PubMed

    Powell, Douglas W; Queen, Robin M; Williams, D S Blaise

    2016-10-01

    To examine lower extremity joint contributions to a landing task in high-(HA) and low-arched (LA) female athletes by quantifying vertical stiffness, joint work and relative joint contributions to landing. Twenty healthy female recreational athletes (10 HA and 10 LA) performed five barefoot drop landings from a height of 30cm. Three-dimensional kinematics (240Hz) and ground reaction forces (960Hz) were recorded simultaneously. Vertical stiffness, joint work values and relative joint work values were calculated using Visual 3D and MatLab. HA athletes had significantly greater vertical stiffness compared to LA athletes (p=0.013). Though no differences in ankle joint work were observed (p=0.252), HA athletes had smaller magnitudes of knee (p=0.046), hip (p=0.019) and total lower extremity joint work values (p=0.016) compared to LA athletes. HA athletes had greater relative contributions of the ankle (p=0.032) and smaller relative contributions of the hip (p=0.049) compared to LA athletes. No differences in relative contributions of the knee were observed (p=0.255). These findings demonstrate that aberrant foot structure is associated with unique contributions of lower extremity joints to load attenuation during landing. These data may provide insight into the unique injury mechanisms associated with arch height in female athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. The effect of ankle-foot orthosis plantarflexion stiffness on ankle and knee joint kinematics and kinetics during first and second rockers of gait in individuals with stroke

    PubMed Central

    Singer, Madeline L.; Kobayashi, Toshiki; Lincoln, Lucas S.; Orendurff, Michael S.; Foreman, K. Bo

    2014-01-01

    Background Stiffness of an ankle-foot orthosis plays an important role in improving gait in patients with a history of stroke. To address this, the aim of this case series study was to determine the effect of increasing plantarflexion stiffness of an ankle-foot orthosis on the sagittal ankle and knee joint angle and moment during the first and second rockers of gait. Methods Gait data were collected in 5 subjects with stroke at a self-selected walking speed under two plantarflexion stiffness conditions (0.4 Nm/deg and 1.3 Nm/deg) using a stiffness-adjustable experimental ankle-foot orthosis on a Bertec split-belt fully instrumented treadmill in a 3-dimensional motion analysis laboratory. Findings By increasing the plantarflexion stiffness of the ankle-foot orthosis, peak plantarfexion angle of the ankle was reduced and peak dorsiflexion moment was generally increased in the first rocker as hypothesized. Two subjects demonstrated increases in both peak knee flexion angle and peak knee extension moment in the second rocker as hypothesized. The two subjects exhibited minimum contractility during active plantarflexion, while the other three subjects could actively plantarflex their ankle joint. Interpretation It was suggested that those with the decreased ability to actively plantarflex their ankle could not overcome excessive plantarflexion stiffness at initial contact of gait, and as a result exhibited compensation strategies at the knee joint. Providing excessively stiff ankle-foot orthoses might put added stress on the extensor muscles of the knee joint, potentially creating fatigue and future pathologies in some patients with stroke. PMID:25241248

  11. Experimental Characterization of Stress- and Strain-Dependent Stiffness in Grouted Rock Masses.

    PubMed

    Kim, Ji-Won; Chong, Song-Hun; Cho, Gye-Chun

    2018-03-29

    Grouting of fractured rock mass prior to excavation results in grout-filled discontinuities that govern the deformation characteristics of a site. The influence of joint characteristics on the properties of grouted rocks is important in assessing the effects of grouting on jointed rock mass. However, grouting remains a predominantly empirical practice and the effects of grouting on rock joint behavior and material properties have yet to be accurately assessed. Granular materials, including jointed rocks, typically display nonlinear strain-dependent responses that can be characterized by the shear modulus degradation curve. In this study, the effects of grouting on the strain-dependent shear stiffness of jointed rock mass were investigated at the small-strain (below 10 -5 ) and mid-strain (10 -5 to 10 -3 ) ranges using the quasi-static resonant column test and rock mass dynamic test devices. The effects of curing time, axial stress, initial joint roughness, and grouted joint thickness were examined. The results show that (1) grouting of rock joints leads to decreased stress sensitivity and increased small-strain shear stiffness for all tested samples; (2) the grouted rock samples display similar modulus degradation characteristics as the applied grout material; (3) the initial joint roughness determines the stress-dependent behaviors and general stiffness range of the jointed and grouted rocks, but the strain-dependent behaviors are dependent on the properties of the grout material; (4) increased grouted joint thickness results in larger contribution of the grout properties in the overall grouted rock mass.

  12. Experimental Characterization of Stress- and Strain-Dependent Stiffness in Grouted Rock Masses

    PubMed Central

    Cho, Gye-Chun

    2018-01-01

    Grouting of fractured rock mass prior to excavation results in grout-filled discontinuities that govern the deformation characteristics of a site. The influence of joint characteristics on the properties of grouted rocks is important in assessing the effects of grouting on jointed rock mass. However, grouting remains a predominantly empirical practice and the effects of grouting on rock joint behavior and material properties have yet to be accurately assessed. Granular materials, including jointed rocks, typically display nonlinear strain-dependent responses that can be characterized by the shear modulus degradation curve. In this study, the effects of grouting on the strain-dependent shear stiffness of jointed rock mass were investigated at the small-strain (below 10−5) and mid-strain (10−5 to 10−3) ranges using the quasi-static resonant column test and rock mass dynamic test devices. The effects of curing time, axial stress, initial joint roughness, and grouted joint thickness were examined. The results show that (1) grouting of rock joints leads to decreased stress sensitivity and increased small-strain shear stiffness for all tested samples; (2) the grouted rock samples display similar modulus degradation characteristics as the applied grout material; (3) the initial joint roughness determines the stress-dependent behaviors and general stiffness range of the jointed and grouted rocks, but the strain-dependent behaviors are dependent on the properties of the grout material; (4) increased grouted joint thickness results in larger contribution of the grout properties in the overall grouted rock mass. PMID:29596371

  13. Neuromuscular properties of different spastic human joints vary systematically.

    PubMed

    Mirbagheri, M M; Settle, K

    2010-01-01

    We quantified the mechanical abnormalities of the spastic wrist in chronic stroke survivors, and determined whether these findings were representative of those recorded at the elbow and ankle joints. System identification techniques were used to characterize the mechanical abnormalities of these joints and to identify the contribution of intrinsic and reflex stiffness to these abnormalities. Modulation of intrinsic and reflex stiffness with the joint angle was studied by applying PRBS perturbations to the joints at different joint angles over the range of motion. Age-matched healthy subjects were used as control.

  14. Kinetic Compensations due to Chronic Ankle Instability during Landing and Jumping.

    PubMed

    Kim, Hyunsoo; Son, S Jun; Seeley, Matthew K; Hopkins, J Ty

    2018-02-01

    Skeletal muscles absorb and transfer kinetic energy during landing and jumping, which are common requirements of various forms of physical activity. Chronic ankle instability (CAI) is associated with impaired neuromuscular control and dynamic stability of the lower extremity. Little is known regarding an intralimb, lower-extremity joint coordination of kinetics during landing and jumping for CAI patients. We investigated the effect of CAI on lower-extremity joint stiffness and kinetic and energetic patterns across the ground contact phase of landing and jumping. One hundred CAI patients and 100 matched able-bodied controls performed five trials of a landing and jumping task (a maximal vertical forward jump, landing on a force plate with the test leg only, and immediate lateral jump toward the contralateral side). Functional analyses of variance and independent t-tests were used to evaluate between-group differences for lower-extremity net internal joint moment, power, and stiffness throughout the entire ground contact phase of landing and jumping. Relative to the control group, the CAI group revealed (i) reduced plantarflexion and knee extension and increased hip extension moments; (ii) reduced ankle and knee eccentric and concentric power, and increased hip eccentric and concentric power, and (iii) reduced ankle and knee joint stiffness and increased hip joint stiffness during the task. CAI patients seemed to use a hip-dominant strategy by increasing the hip extension moment, stiffness, and eccentric and concentric power during landing and jumping. This apparent compensation may be due to decreased capabilities to produce sufficient joint moment, stiffness, and power at the ankle and knee. These differences might have injury risk and performance implications.

  15. Virtual trajectories, joint stiffness, and changes in the limb natural frequency during single-joint oscillatory movements.

    PubMed

    Latash, M L

    1992-07-01

    In the framework of the equilibrium-point hypothesis, virtual trajectories and patterns of joint stiffness were reconstructed during voluntary single-joint oscillatory movements in the elbow joint at a variety of frequencies and against two inertial loads. At low frequencies, virtual trajectories were in-phase with the actual joint trajectories. Joint stiffness changed at a doubled frequency. An increase in movement frequency and/or inertial load led to an increase in the difference between the peaks of the actual and virtual trajectories and in both peak and averaged values of joint stiffness. At a certain, critical frequency, virtual trajectory was nearly flat. Further increase in movement frequency led to a 180 degree phase shift between the actual and virtual trajectories. The assessed values of the natural frequency of the system "limb + manipulandum" were close to the critical frequencies for both low and high inertial loads. Peak levels and integrals of the electromyograms of two flexor and two extensor muscles changed monotonically with movement frequency without any special behavior at the critical frequencies. Nearly flat virtual trajectories at the natural frequency make physical sense as hypothetical control signals, unlike the electromyographic recordings, since a system at its natural frequency requires minimal central interference. Modulation of joint stiffness is assumed to be an important adaptive mechanism attenuating difference between the system's natural frequency and desired movement frequency. Virtual trajectory is considered a behavioral observable. Phase transitions between the virtual and actual trajectories are illustrations of behavioral discontinuities introduced by slow changes in a higher level control parameter, movement frequency. Relative phase shift between these two trajectories may be considered an order parameter.

  16. Behavior of Fiber Glass Bolts, Rock Bolts and Cable Bolts in Shear

    NASA Astrophysics Data System (ADS)

    Li, Xuwei; Aziz, Naj; Mirzaghorbanali, Ali; Nemcik, Jan

    2016-07-01

    This paper experimentally compares the shear behavior of fiber glass (FG) bolt, rock bolt (steel rebar bolt) and cable bolt for the bolt contribution to bolted concrete surface shear strength, and bolt failure mode. Two double shear apparatuses of different size were used for the study. The tensile strength, the shear strength and the deformation modulus of bolt control the shear behavior of a sheared bolted joint. Since the strength and deformation modulus of FG bolt, rock bolt and cable bolt obtained from uniaxial tensile tests are different, their shear behavior in reinforcing joints is accordingly different. Test results showed that the shear stiffness of FG bolted joints decreased gradually from the beginning to end, while the shear stiffness of joints reinforced by rock bolt and cable bolt decreased bi-linearly, which is clearly consistent with their tensile deformation modulus. The bolted joint shear stiffness was highly influenced by bolt pretension in the high stiffness stage for both rock bolt and cable bolt, but not in the low stiffness stage. The rock bolt contribution to joint shear strength standardised by the bolt tensile strength was the largest, followed by cable bolts, then FG bolts. Both the rock bolts and cable bolts tended to fail in tension, while FG bolts in shear due to their low shear strength and constant deformation modulus.

  17. An analytical investigation of a conceptual design for the station transverse boom rotary joint structure

    NASA Technical Reports Server (NTRS)

    Lake, M. S.; Bush, H. G.

    1986-01-01

    A study was conducted to define an annular ring, discrete roller assembly concept for the space station transverse boom rotary joint. The concept was analyzed using closed-form and finite element techniques, to size structural members for a range of joint diameters and to determine necessary equivalent stiffnesses for the roller assemblies. Also, a mass study of the system was conducted to determine its practicality, and maximum loads in the joint were identified. To obtain the optimum balance between high stiffness and low structural mass in the design of the rotary joint, it is necessary to maximize the diameter of the annular ring within operational constraints (i.e., shuttle cargo bay size). Further, a rotary joint designed with the largest possible ring diameter will result in minimum operational loads in both the roller assemblies and the transition truss members while also allowing minimum design stiffnesses for the roller assemblies.

  18. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  19. Temporary ipsilateral stiff shoulder after operative fixation of distal radial fractures.

    PubMed

    Cha, Soo Min; Shin, Hyun Dae; Hwang, Sung Jin

    2017-06-01

    This study was conducted to identify variables affecting the development of temporary stiff shoulder after operative fixation for distal radial fractures (DRF). The study retrospectively analyzed 167 patients who had undergone internal fixation using volar locking plate for DRF between 2010 and 2013. Group 1 was denoted as the "normal group," and group 2 was denoted as the "stiff shoulder group." Basic demographic factors evaluated included age, sex, bone mineral density (BMD), and the dominancy. Also investigated were radiologic variables, including concurrent fractures of the styloid process, positive ulnar variances, classification of DRF, and morphologic type of the distal radioulnar joint. Finally, the type of plate, methods used for postoperative protection, and time of union were analyzed. Group 1 consisted of 114 patients, and group 2 consisted of 53 patients. On overall univariate analysis, BMD, hand dominancy, and the protective methods after plating were significantly different between the 2 groups. On multivariate analysis, a lower BMD and injury on the nondominant side were significant factors for shoulder stiffness. Stiffness was significantly higher in patients with a mean BMD < -2.6 than in patients with a mean BMD ≥ -2.6. At the final follow-up, all of the 53 patients in group 2 were relieved of the symptoms of a stiff shoulder. A lower BMD and injury on the nondominant distal radius were distinct factors for the development of a stiff shoulder after operative fixation in DRF. Fortunately, nonoperative treatments, such as stretching exercises/injections, were useful for the relief of these symptoms in the short-term follow-up. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. A Novel Concept for Safe, Stiffness-Controllable Robot Links.

    PubMed

    Stilli, Agostino; Wurdemann, Helge A; Althoefer, Kaspar

    2017-03-01

    The recent decade has seen an astounding increase of interest and advancement in a new field of robotics, aimed at creating structures specifically for the safe interaction with humans. Softness, flexibility, and variable stiffness in robotics have been recognized as highly desirable characteristics for many applications. A number of solutions were proposed ranging from entirely soft robots (such as those composed mainly from soft materials such as silicone), via flexible continuum and snake-like robots, to rigid-link robots enhanced by joints that exhibit an elastic behavior either implemented in hardware or achieved purely by means of intelligent control. Although these are very good solutions paving the path to safe human-robot interaction, we propose here a new approach that focuses on creating stiffness controllability for the linkages between the robot joints. This article proposes a replacement for the traditionally rigid robot link-the new link is equipped with an additional capability of stiffness controllability. With this added feature, a robot can accurately carry out manipulation tasks (high stiffness), but can virtually instantaneously reduce its stiffness when a human is nearby or in contact with the robot. The key point of the invention described here is a robot link made of an airtight chamber formed by a soft and flexible, but high-strain resistant combination of a plastic mesh and silicone wall. Inflated with air to a high pressure, the mesh silicone chamber behaves like a rigid link; reducing the air pressure, softens the link and rendering the robot structure safe. This article investigates a number of link prototypes and shows the feasibility of the new concept. Stiffness tests have been performed, showing that a significant level of stiffness can be achieved-up to 40 N reaction force along the axial direction, for a 25-mm-diameter sample at 60 kPa, at an axial deformation of 5 mm. The results confirm that this novel concept to linkages for robot manipulators exhibits the beam-like behavior of traditional rigid links when fully pressurized and significantly reduced stiffness at low pressure. The proposed concept has the potential to easily create safe robots, augmenting traditional robot designs.

  1. Biomimetic-inspired joining of composite with metal structures: A survey of natural joints and application to single lap joints

    NASA Astrophysics Data System (ADS)

    Avgoulas, Evangelos Ioannis; Sutcliffe, Michael P. F.

    2014-03-01

    Joining composites with metal parts leads, inevitably, to high stress concentrations because of the material property mismatch. Since joining composite to metal is required in many high performance structures, there is a need to develop a new multifunctional approach to meet this challenge. This paper uses the biomimetics approach to help develop solutions to this problem. Nature has found many ingenious ways of joining dissimilar materials and making robust attachments, alleviating potential stress concentrations. A literature survey of natural joint systems has been carried out, identifying and analysing different natural joint methods from a mechanical perspective. A taxonomy table was developed based on the different methods/functions that nature successfully uses to attach dissimilar tissues (materials). This table is used to understand common themes or approaches used in nature for different joint configurations and functionalities. One of the key characteristics that nature uses to joint dissimilar materials is a transitional zone of stiffness in the insertion site. Several biomimetic-inspired metal-to-composite (steel-to-CFRP), adhesively bonded, Single Lap Joints (SLJs) were numerically investigated using a finite element analysis. The proposed solutions offer a transitional zone of stiffness of one joint part to reduce the material stiffness mismatch at the joint. An optimisation procedure was used to identify the variation in material stiffness which minimises potential failure of the joint. It was found that the proposed biomimetic SLJs reduce the asymmetry of the stress distribution along the adhesive area.

  2. Differentiation between non-neural and neural contributors to ankle joint stiffness in cerebral palsy

    PubMed Central

    2013-01-01

    Background Spastic paresis in cerebral palsy (CP) is characterized by increased joint stiffness that may be of neural origin, i.e. improper muscle activation caused by e.g. hyperreflexia or non-neural origin, i.e. altered tissue viscoelastic properties (clinically: “spasticity” vs. “contracture”). Differentiation between these components is hard to achieve by common manual tests. We applied an assessment instrument to obtain quantitative measures of neural and non-neural contributions to ankle joint stiffness in CP. Methods Twenty-three adolescents with CP and eleven healthy subjects were seated with their foot fixated to an electrically powered single axis footplate. Passive ramp-and-hold rotations were applied over full ankle range of motion (RoM) at low and high velocities. Subject specific tissue stiffness, viscosity and reflexive torque were estimated from ankle angle, torque and triceps surae EMG activity using a neuromuscular model. Results In CP, triceps surae reflexive torque was on average 5.7 times larger (p = .002) and tissue stiffness 2.1 times larger (p = .018) compared to controls. High tissue stiffness was associated with reduced RoM (p < .001). Ratio between neural and non-neural contributors varied substantially within adolescents with CP. Significant associations of SPAT (spasticity test) score with both tissue stiffness and reflexive torque show agreement with clinical phenotype. Conclusions Using an instrumented and model based approach, increased joint stiffness in CP could be mainly attributed to higher reflexive torque compared to control subjects. Ratios between contributors varied substantially within adolescents with CP. Quantitative differentiation of neural and non-neural stiffness contributors in CP allows for assessment of individual patient characteristics and tailoring of therapy. PMID:23880287

  3. Differentiation between non-neural and neural contributors to ankle joint stiffness in cerebral palsy.

    PubMed

    de Gooijer-van de Groep, Karin L; de Vlugt, Erwin; de Groot, Jurriaan H; van der Heijden-Maessen, Hélène C M; Wielheesen, Dennis H M; van Wijlen-Hempel, Rietje M S; Arendzen, J Hans; Meskers, Carel G M

    2013-07-23

    Spastic paresis in cerebral palsy (CP) is characterized by increased joint stiffness that may be of neural origin, i.e. improper muscle activation caused by e.g. hyperreflexia or non-neural origin, i.e. altered tissue viscoelastic properties (clinically: "spasticity" vs. "contracture"). Differentiation between these components is hard to achieve by common manual tests. We applied an assessment instrument to obtain quantitative measures of neural and non-neural contributions to ankle joint stiffness in CP. Twenty-three adolescents with CP and eleven healthy subjects were seated with their foot fixated to an electrically powered single axis footplate. Passive ramp-and-hold rotations were applied over full ankle range of motion (RoM) at low and high velocities. Subject specific tissue stiffness, viscosity and reflexive torque were estimated from ankle angle, torque and triceps surae EMG activity using a neuromuscular model. In CP, triceps surae reflexive torque was on average 5.7 times larger (p = .002) and tissue stiffness 2.1 times larger (p = .018) compared to controls. High tissue stiffness was associated with reduced RoM (p < .001). Ratio between neural and non-neural contributors varied substantially within adolescents with CP. Significant associations of SPAT (spasticity test) score with both tissue stiffness and reflexive torque show agreement with clinical phenotype. Using an instrumented and model based approach, increased joint stiffness in CP could be mainly attributed to higher reflexive torque compared to control subjects. Ratios between contributors varied substantially within adolescents with CP. Quantitative differentiation of neural and non-neural stiffness contributors in CP allows for assessment of individual patient characteristics and tailoring of therapy.

  4. Free vibrations of a pultruded GFRP frame with different rotational stiffnesses of bolted joints

    NASA Astrophysics Data System (ADS)

    Boscato, G.; Russo, S.

    2013-01-01

    Experimental and numerical results for the dynamic response of an all-FRP (fiber-reinforced polymer) twodimensional frame in free vibration are presented. The frame was assembled of pultruded glass-fiber-reinforced polymer (GFRP) profiles and bolted beam-to-column connections with GFRP angles. To give a variable rotational stiffness to the four beam-to-column major-axis joints, all bolts were tightened by a constant torque of 10, 25, or 40 N · m. Experimental measurements were performed on the three configurations to identify the natural frequencies of the first vibration mode in the plane of the frame and to determine the ability of each structure to dissipate the initial acceleration imposed on it through damping. The results obtained are compared with analytical and finite-element calculations. It was found that an increased bolt torque improved the dynamic response of the GFRP frame by reducing its vibration time and maximum displacements and by enhancing its dissipation capacity.

  5. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

    PubMed

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-08-30

    Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.

  6. Application of traction drives as servo mechanisms

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.; Steinetz, B. M.

    1985-01-01

    The suitability of traction drives for a wide class of aerospace control mechanisms is examined. Potential applications include antenna or solar array drive positioners, robotic joints, control moment gyro (CMG) actuators and propeller pitch change mechanisms. In these and similar applications the zero backlash, high torsional stiffness, low hysteresis and torque ripple characteristics of traction drives are of particular interest, as is the ability to run without liquid lubrication in certain cases. Wear and fatigue considerations for wet and dry operation are examined along with the tribological performance of several promising self lubricating polymers for traction contracts. The speed regulation capabilities of variable ratio traction drives are reviewed. A torsional stiffness analysis described suggests that traction contacts are relatively stiff compared to gears and are significantly stiffer than the other structural elements in the prototype CMG traction drive analyzed. Discussion is also given of an advanced turboprop propeller pitch change mechanism that incorporates a traction drive.

  7. BioMot exoskeleton - Towards a smart wearable robot for symbiotic human-robot interaction.

    PubMed

    Bacek, Tomislav; Moltedo, Marta; Langlois, Kevin; Prieto, Guillermo Asin; Sanchez-Villamanan, Maria Carmen; Gonzalez-Vargas, Jose; Vanderborght, Bram; Lefeber, Dirk; Moreno, Juan C

    2017-07-01

    This paper presents design of a novel modular lower-limb gait exoskeleton built within the FP7 BioMot project. Exoskeleton employs a variable stiffness actuator in all 6 joints, a directional-flexibility structure and a novel physical humanrobot interfacing, which allows it to deliver the required output while minimally constraining user's gait by providing passive degrees of freedom. Due to modularity, the exoskeleton can be used as a full lower-limb orthosis, a single-joint orthosis in any of the three joints, and a two-joint orthosis in a combination of any of the two joints. By employing a simple torque control strategy, the exoskeleton can be used to deliver user-specific assistance, both in gait rehabilitation and in assisting people suffering musculoskeletal impairments. The result of the presented BioMot efforts is a low-footprint exoskeleton with powerful compliant actuators, simple, yet effective torque controller and easily adjustable flexible structure.

  8. Astym® Therapy for the Management of Recalcitrant Knee Joint Stiffness after Total Knee Arthroplasty.

    PubMed

    Bhave, Anil; Corcoran, James; Cherian, Jeffery J; Mont, Michael A

    2016-01-01

    Knee stiffness is a common complication after total knee arthroplasty (TKA). Despite studies published on the surgical management of reduced range of motion (ROM) after TKA, there is limited evidence on the nonoperative management of joint and soft tissue imbalances possibly contributing to reduced knee ROM. This report assesses changes in ROM, pain, function, and patellar tendon length after Astym® joint mobilization use. A 38-year-old male professional skier had a right TKA 3 months before presentation with 2 subsequent manipulations under anesthesia secondary to persistent knee stiffness. He had patellar baja on radiograph, a reduced arc of ROM, reduced patellar mobility and muscular extensibility, and pain to palpation along the patellar tendon. He had 12 visits of physical therapy with the use of Astym®, patellar mobilization, and tibio-femoral mobilizations with movement. The patient also used a customized knee device at home for prolonged knee extension stretching. The patient was treated for 12 visits, along with home use of customized bracing for knee extension. Significant improvements were seen in pain, function, and ROM. He returned to work full-time, ambulated prolonged distances, and negotiated stairs pain-free. He also demonstrated resolution of patellar baja radiographically. Conservative management of recalcitrant knee joint stiffness after primary TKA can be effective in restoring knee mobility and reducing pain and activity limitation. A multimodal approach using Astym® treatment, customized knee bracing, and targeted joint mobilization can be effective in resolving knee joint stiffness.

  9. Lower Body Stiffness and Muscle Activity Differences Between Female Dancers and Basketball Players During Drop Jumps

    PubMed Central

    Ambegaonkar, Jatin P.; Shultz, Sandra J.; Perrin, David H.; Schmitz, Randy J.; Ackerman, Terry A.; Schulz, Mark R.

    2011-01-01

    Background: Anterior cruciate ligament (ACL) injuries often occur during landing, with female athletes at higher injury risk than male athletes. Interestingly, female dancers have lower ACL injury rates than do female athletes in general. Hypothesis: Female dancers will have earlier and greater lower extremity muscle activity and higher sagittal knee joint and leg stiffness than will female basketball players. Study Design: Cross-sectional group comparison. Methods: Fifty-five healthy female athletes (35 dancers, 20 basketball players) performed 5 double-leg drop jumps from a 45-cm box. Surface electromyography (onsets and amplitudes; prelanding and postlanding) was recorded from the lateral gastrocnemius, medial and lateral hamstrings, lateral quadriceps muscles with a 3-dimensional electromagnetic tracking system, and forceplates recording biomechanics (leg spring stiffness and knee joint stiffness). Results: Compared with basketball players, dancers had greater leg spring stiffness (P = 0.047) but similar knee joint stiffness (P = 0.44). Although no significant differences were observed in overall muscle onset times (P = 0.22) or activation amplitudes (prelanding, P = 0.60; postlanding, P = 0.78), small to moderate effect sizes (ESs) suggest trends in dancers toward earlier (ES = 0.53) and higher medial hamstrings activation pre- (ES = 0.55) and post- (ES = 0.41) landing and lower lateral quadriceps (ES = 0.30) and higher gastrocnemius (ES = 0.33) postlanding muscle activation. Conclusions: In dancers, the higher leg spring stiffness and trends toward higher hamstrings prelanding and postlanding, as well as lower quadriceps and higher gastrocnemius activation postlanding with similar knee joint stiffness, indicate lower extremity neuromechanical differences across other joints. Clinical Relevance: Female dancers may have lower extremity neuromechanics that are different from those of basketball players during drop jumps. If dancers use ACL-protective strategies during activity, then their training routines should be further investigated to improve ACL injury prevention programs. PMID:23015996

  10. Associations of passive muscle stiffness, muscle stretch tolerance, and muscle slack angle with range of motion: individual and sex differences.

    PubMed

    Miyamoto, Naokazu; Hirata, Kosuke; Miyamoto-Mikami, Eri; Yasuda, Osamu; Kanehisa, Hiroaki

    2018-05-29

    Joint range of motion (ROM) is an important parameter for athletic performance and muscular injury risk. Nonetheless, a complete description of muscular factors influencing ROM among individuals and between men and women is lacking. We examined whether passive muscle stiffness (evaluated by angle-specific muscle shear modulus), tolerance to muscle stretch (evaluated by muscle shear modulus at end-ROM), and muscle slack angle of the triceps surae are associated with the individual variability and sex difference in dorsiflexion ROM, using ultrasound shear wave elastography. For men, ROM was negatively correlated to passive muscle stiffness of the medial and lateral gastrocnemius in a tensioned state and positively to tolerance to muscle stretch in the medial gastrocnemius. For women, ROM was only positively correlated to tolerance to muscle stretch in all muscles but not correlated to passive muscle stiffness. Muscle slack angle was not correlated to ROM in men and women. Significant sex differences were observed only for dorsiflexion ROM and passive muscle stiffness in a tensioned state. These findings suggest that muscular factors associated with ROM are different between men and women. Furthermore, the sex difference in dorsiflexion ROM might be attributed partly to that in passive muscle stiffness of plantar flexors.

  11. Assessment of passive knee stiffness and viscosity in individuals with spinal cord injury using pendulum test.

    PubMed

    Joghtaei, Mahmoud; Arab, Amir Massoud; Hashemi-Nasl, Hamed; Joghataei, Mohammad Taghi; Tokhi, Mohammad Osman

    2015-03-01

    Stiffness and viscosity represent passive resistances to joint motion related with the structural properties of the joint tissue and of the musculotendinous complex. Both parameters can be affected in patients with spinal cord injury (SCI). The purpose of this study was to measure passive knee stiffness and viscosity in patients with SCI with paraplegia and healthy subjects using Wartenberg pendulum test. Non-experimental, cross-sectional, case-control design. An outpatient physical therapy clinic, University of social welfare and Rehabilitation Science, Iran. A sample of convenience sample of 30 subjects participated in the study. Subjects were categorized into two groups: individuals with paraplegic SCI (n = 15, age: 34.60 ± 9.18 years) and 15 able-bodied individuals as control group (n = 15, age: 30.66 ± 11.13 years). Not applicable. Passive pendulum test of Wartenberg was used to measure passive viscous-elastic parameters of the knee (stiffness, viscosity) in all subjects. Statistical analysis (independent t-test) revealed significant difference in the joint stiffness between healthy subjects and those with paraplegic SCI (P = 0.01). However, no significant difference was found in the viscosity between two groups (P = 0.17). Except for first peak flexion angle, all other displacement kinematic parameters exhibited no statistically significant difference between normal subjects and subjects with SCI. Patients with SCI have significantly greater joint stiffness compared to able-bodied subjects.

  12. Is stiffness related to athletic groin pain?

    PubMed

    Gore, S J; Franklyn-Miller, A; Richter, C; Falvey, E C; King, E; Moran, K

    2018-06-01

    Athletic groin pain (AGP) is a common injury prevalent in field sports. One biomechanical measure that may be of importance for injury risk is stiffness. To date however, stiffness has not been examined in AGP. The primary aim was to determine whether AGP affects vertical and joint stiffness and if so, whether successful rehabilitation is associated with a change in stiffness. Sixty-five male patients with AGP and fifty male controls were recruited to this study. Assessment included a biomechanical examination of stiffness during a lateral hurdle hop test. Subjects with AGP were tested pre- and post-rehabilitation, while controls were tested once. AGP subjects were cleared for return to play in a median time of 9.14 weeks (5.14-29.0). Stiffness was significantly different at pre-rehabilitation in comparison with controls for four of the ten stiffness values examined: ankle plantar flexor, knee extensor, hip abductor, and vertical stiffness (P < .05, D = 0.36-0.79). Despite clearance for return to play, of these four variables, only hip abductor stiffness changed significantly from pre- to post-rehabilitation (P = .05, D = 0.35) to become non-significantly different to the uninjured group (P = .18, D = 0.26). These findings suggest that hip abductor stiffness may represent a target for AGP rehabilitation. Conversely, given the clearance for return to play, the lower sagittal plane and vertical stiffness in the AGP group in comparison with the uninjured controls likely represents either a compensatory mechanism to reduce the risk of further injury or a consequence of neuromuscular detraining. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Integrated, proportionally controlled, and naturally compliant universal joint actuator with controllable stiffness

    DOEpatents

    Borenstein, Johann; Granosik, Grzegorz

    2005-03-22

    An apparatus for traversing obstacles having an elongated, round, flexible body that includes a plurality of segments interconnected by an integrated joint actuator assembly. The integrated joint actuator assembly includes a plurality of bellows-type actuators individually coupling adjacent segments to permit pivotal actuation of the apparatus therebetween. A controller is employed to maintain proper positional control and stiffness control while minimize air flow.

  14. Stiffness is more than just duration and severity: a qualitative exploration in people with rheumatoid arthritis

    PubMed Central

    Dures, Emma; Kirwan, John; Pollock, Jon; Baker, Gill; Edmunds, Avis; Hewlett, Sarah

    2015-01-01

    Objective. Stiffness is internationally recognized as an important indicator of inflammatory activity in RA but is poorly understood and difficult to measure. The aim of this study was to explore the experience of stiffness from the patient perspective. Methods. Semi-structured interviews conducted with 16 RA patients were analysed independently by researchers and pat.ient partners using inductive thematic analysis. Results. Six themes were identified. Part of having RA identified stiffness as a normal consequence of RA, perceived as associated with disease-related aspects such as fluctuating disease activity, other RA symptoms and disease duration. Local and widespread highlighted stiffness occurring not only in joints, but also over the whole body, being more widespread during the morning or flare. Linked to behaviour and environment illustrated factors that influence stiffness, including movement, medications and weather. Highly variable captured the fluctuating nature of stiffness within and between patients and in relation to temporality, duration and intensity. Impacts on daily life emphasized the effect of stiffness on a range of domains, including physical function, quality of life, psychological well-being, activities of daily living and participation in work and leisure activities. Requires self-management detailed self-management strategies targeting both the symptom and its consequences. Conclusion. Patients’ experiences of stiffness were varied, complex and not exclusive to the morning period. Importantly, stiffness was reported in terms of impact rather than the traditional measurement concepts of severity or duration. Based on these findings, further research is needed to develop a patient-centred measure that adequately reflects inflammatory activity. PMID:25231178

  15. Correlations among measures of knee stiffness, gait performance and complaints in individuals with knee osteoarthritis.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J

    2013-03-01

    Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; P<.05) and between Western Ontario and McMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; P<.05). The damping coefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Knee stiffness and viscosity: New implementation and perspectives in prosthesis development

    PubMed Central

    Bohinc, Klemen; Vantur, Nejc; Torkar, Drago; Lampe, Tomaž; Hribernik, Marija; Jakovljević, Miroljub

    2017-01-01

    The pendulum test is a method applied to measure passive resistance of the knee. A new and simple pendulum test with instrumentation based on infrared camera was used to evaluate knee stiffness and viscosity on a female human cadaver. The stiffness and viscosity were calculated based on the kinetic data. During the measurements, the periarticular and intraarticular soft tissue of the knee was gradually removed to determine the stiffness and viscosity as a function of the tissue removal rate. The measurements showed that the removal of tissue around the joint reduces the damping of leg oscillation, and therefore decreases the stiffness and viscosity. The contribution to knee joint damping was 10% for the skin, 20% for ligaments, and 40% for muscles and tendons. Tissue removal has a very large impact on the knee stiffness and viscosity. PMID:28422623

  17. Knee stiffness and viscosity: New implementation and perspectives in prosthesis development.

    PubMed

    Bohinc, Klemen; Vantur, Nejc; Torkar, Drago; Lampe, Tomaž; Hribernik, Marija; Jakovljević, Miroljub

    2017-05-20

    The pendulum test is a method applied to measure passive resistance of the knee. A new and simple pendulum test with instrumentation based on infrared camera was used to evaluate knee stiffness and viscosity on a female human cadaver. The stiffness and viscosity were calculated based on the kinetic data. During the measurements, the periarticular and intraarticular soft tissue of the knee was gradually removed to determine the stiffness and viscosity as a function of the tissue removal rate. The measurements showed that the removal of tissue around the joint reduces the damping of leg oscillation, and therefore decreases the stiffness and viscosity. The contribution to knee joint damping was 10% for the skin, 20% for ligaments, and 40% for muscles and tendons. Tissue removal has a very large impact on the knee stiffness and viscosity.

  18. A review of models of vertical, leg, and knee stiffness in adults for running, jumping or hopping tasks.

    PubMed

    Serpell, Benjamin G; Ball, Nick B; Scarvell, Jennie M; Smith, Paul N

    2012-01-01

    The 'stiffness' concept originates from Hooke's law which states that the force required to deform an object is related to a spring constant and the distance that object is deformed. Research into stiffness in the human body is undergoing unprecedented popularity; possibly because stiffness has been associated with sporting performance and some lower limb injuries. However, some inconsistencies surrounding stiffness measurement exists bringing into question the integrity of some research related to stiffness. The aim of this study was to review literature which describes how vertical, leg and knee stiffness has been measured in adult populations while running, jumping or hopping. A search of the entire MEDLINE, PubMed and SPORTDiscus databases and an iterative reference check was performed. Sixty-seven articles were retrieved; 21 measured vertical stiffness, 51 measured leg stiffness, and 22 measured knee stiffness. Thus, some studies measured several 'types' of stiffness. Vertical stiffness was typically the quotient of ground reaction force and centre of mass displacement. For leg stiffness it was and change in leg length, and for the knee it was the quotient of knee joint moments and change in joint angle. Sample size issues and measurement techniques were identified as limitations to current research.

  19. [Correlations Between Joint Proprioception, Muscle Strength, and Functional Ability in Patients with Knee Osteoarthritis].

    PubMed

    Chen, Yoa; Yu, Yong; He, Cheng-qi

    2015-11-01

    To establish correlations between joint proprioception, muscle flexion and extension peak torque, and functional ability in patients with knee osteoarthritis (OA). Fifty-six patients with symptomatic knee OA were recruited in this study. Both proprioceptive acuity and muscle strength were measured using the isomed-2000 isokinetic dynamometer. Proprioceptive acuity was evaluated by establishing the joint motion detection threshold (JMDT). Muscle strength was evaluated by Max torque (Nm) and Max torque/weight (Nm/ kg). Functional ability was assessed by the Western Ontario and McMaster Universities Osteoarthritis Index physical function (WOMAC-PF) questionnaire. Correlational analyses were performed between proprioception, muscle strength, and functional ability. A multiple stepwise regression model was established, with WOMAC-PF as dependent variable and patient age, body mass index (BMI), visual analogue scale (VAS)-score, mean grade for Kellgren-Lawrance of both knees, mean strength for quadriceps and hamstring muscles of both knees, and mean JMDT of both knees as independent variables. Poor proprioception (high JMDT) was negatively correlated with muscle strength (P<0.05). There was no significant correlation between knee proprioception (high JMDT) and joint pain (WOMAC pain score), and between knee proprioception (high JMDT) and joint stiffness (WOMAC stiffness score). Poor proprioception (high JMDT) was correlated with limitation in functional ability (WOMAC physical function score r=0.659, P<0.05). WOMAC score was correlated with poor muscle strength (quadriceps muscle strength r = -0.511, P<0.05, hamstring muscle strength r = -0.408, P<0.05). The multiple stepwise regression model showed that high JMDT C standard partial regression coefficient (B) = 0.385, P<0.50 and high VAS-scale score (B=0.347, P<0.05) were significant predictors of WOMAC-PF score. Patients with poor proprioception is associated with poor muscle strength and limitation in functional ability. Patients with symptomatic OA of knees commonly endure with moderate to considerable dysfunction, which is associated with poor proprioception (high JMDT) and high VAS-scale score.

  20. Knee joint stiffness in individuals with and without knee osteoarthritis: a preliminary study.

    PubMed

    Oatis, Carol A; Wolff, Edward F; Lennon, Sandra K

    2006-12-01

    Descriptive, case-matched comparison. To compare the knee joint stiffness and damping coefficients of individuals with knee osteoarthritis (KOA) to those of age- and gender-matched individuals without KOA. A secondary purpose was to investigate relationships between these coefficients and complaints of stiffness in individuals with KOA. KOA is a leading cause of disability, and stiffness is a common complaint in individuals with KOA. Yet the most common method of assessing knee joint stiffness is through a self-report questionnaire. Stiffness and damping coefficients at the knee were calculated in 10 volunteers (mean age +/- SD, 64.1+/-15.5 years) with KOA and compared to coefficients from age-and gender-matched individuals without KOA, collected in a previous study (mean age +/- SD, 62.1+/-13.9 years). Stiffness and damping coefficients were calculated from the angular motion of the knee during a relaxed oscillation. Spearman correlation coefficients were calculated between stiffness and damping coefficients and WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) scores for subjects with KOA. Independent 2-tailed t tests revealed significantly larger damping coefficients (P = .035) among those with KOA (95% CI, 0.10-2.32 Nm s/rad). Spearman rank correlations revealed a significant positive relationship (r = .85, P = .003) between the damping coefficient and the stiffness subscore of the WOMAC. This study offers preliminary data demonstrating the feasibility of measuring stiffness and damping coefficients in individuals with KOA. Additionally, the damping coefficient is increased in people with KOA when compared to age- and gender-matched individuals without KOA. The damping coefficient appears to be associated with the complaints of stiffness reported by the WOMAC.

  1. Linear parameter varying identification of ankle joint intrinsic stiffness during imposed walking movements.

    PubMed

    Sobhani Tehrani, Ehsan; Jalaleddini, Kian; Kearney, Robert E

    2013-01-01

    This paper describes a novel model structure and identification method for the time-varying, intrinsic stiffness of human ankle joint during imposed walking (IW) movements. The model structure is based on the superposition of a large signal, linear, time-invariant (LTI) model and a small signal linear-parameter varying (LPV) model. The methodology is based on a two-step algorithm; the LTI model is first estimated using data from an unperturbed IW trial. Then, the LPV model is identified using data from a perturbed IW trial with the output predictions of the LTI model removed from the measured torque. Experimental results demonstrate that the method accurately tracks the continuous-time variation of normal ankle intrinsic stiffness when the joint position changes during the IW movement. Intrinsic stiffness gain decreases from full plantarflexion to near the mid-point of plantarflexion and then increases substantially as the ankle is dosriflexed.

  2. Experimental behaviour of beam-column connection using cold-formed steel sections with rectangular gusset-plate

    NASA Astrophysics Data System (ADS)

    Aminuddin, K. M.; Saggaff, Anis; Tahir, Mahmood Md

    2017-11-01

    Beam-to-column connections setting up as isolated joint of cold-formed steel sections were tested up to failure. This experiment was conducted to observe the behaviour of connection in term of strength, stiffness and ductility. The type of connection used was rectangular gusset plate which stiffen the beam-to-column connection. The behaviour of the proposed connection was expressed with Moment-Rotation curves plotted from the experiment test results. The capacity of connections on this research were done in two ways: theoretical calculation by adopting Eurocode 3 BS EN 1993-1-8:2005 and experimental test results. The theoretical calculation of the moment capacit y of the proposed connection has found (Mj) to be 10.78 kNm with joint stiffness (Sj) amount to 458.53 kNm/rad. The experimental test results has recorded that the Moment capacity (Mj) of 15.68 kNm with joint stiffness (Sj) of 1948.06 kNm/rad. The moment ratio of theoretical to experimental amount to 0.69. The joint stiffness ratio of theoretical to experimental amount to 0.24.

  3. Biomechanical effects of transverse partial sacrectomy on the sacroiliac joints: an in vitro human cadaveric investigation of the borderline of sacroiliac joint instability.

    PubMed

    Yu, Binsheng; Zheng, Zhaomin; Zhuang, Xinming; Chen, Hui; Xie, Denghui; Luk, K D K; Lu, W W

    2009-06-01

    In vitro laboratory study. To measure the effects of transverse partial sacrectomies on the compressive and torsional stiffness of the sacroiliac joints. Surgical treatment for sacral tumor of different location and nature includes partial or complete sacrectomy. Though the biomechanical investigations about the local destructive force of residual sacrum after partial sacrectomy have been reported, biomechanical properties of the residual sacroiliac joints after different transverse partial sacrectomies remain unknown. Seven fresh human cadaveric L5-pelves with normal bone mineral density were used in this study. Each specimen was tested in intact condition first, followed by a series of segmental transverse partial sacrectomies: under S2 partial sacrectomy (U-S2); U-(1/2)S2; U-S1; U-(1/2)S1; and right side sacroiliac joint resection (one-side). A material testing machine was used to apply 800 N compression and 7 Nm torsion loads through the L5/S1 joint. The resected dimensional area of sacroiliac joints and structural stiffness of the residual sacroiliac joints were analyzed. Average percentages of the resected area of sacroiliac joints were 8.4% in U-S2, 15.1% in U-(1/2)S2, 24.8% in U-S1, and 72.3% in U-(1/2)S1, respectively. In compression U-S2 approximately one-side preserved 98.7%, 97.1%, 94.4%, 82.9%, and 55.2% of the initial stiffness of the sacroiliac joint, respectively. No significant differences were detected among intact, U-S2, U-(1/2)S2, and U-S1 (P > 0.05). However, compressive stiffness of U-(1/2)S1 and one-side was markedly less than that of intact, U-S2, and U-(1/2)S2 (P < 0.05). In Torsion U-S2 approximately one-side preserved 90.7%, 88.5%, 81.9%, 71.9%, and 44.5% of the initial sacroiliac joint stiffness, respectively. No significant differences were demonstrated among intact, U-S2, and U-(1/2)S2 (P > 0.05); However, U-S1, U-(1/2)S1 and one-side exhibited significantly less torsional stiffness than intact and U-S2 (P < 0.05). In surgical treatment of distal sacral tumor, transverse partial sacrectomy involving S1 could result in rotational instability, and the resection level beyond (1/2)S1 further led to compressive instability. When the sacrectomy was at or above the S1/2 level, local reconstruction should be considered.

  4. Low-Friction, High-Stiffness Joint for Uniaxial Load Cell

    NASA Technical Reports Server (NTRS)

    Lewis, James L.; Le, Thang; Carroll, Monty B.

    2007-01-01

    A universal-joint assembly has been devised for transferring axial tension or compression to a load cell. To maximize measurement accuracy, the assembly is required to minimize any moments and non-axial forces on the load cell and to exhibit little or no hysteresis. The requirement to minimize hysteresis translates to a requirement to maximize axial stiffness (including minimizing backlash) and a simultaneous requirement to minimize friction. In practice, these are competing requirements, encountered repeatedly in efforts to design universal joints. Often, universal-joint designs represent compromises between these requirements. The improved universal-joint assembly contains two universal joints, each containing two adjustable pairs of angular-contact ball bearings. One might be tempted to ask why one could not use simple ball-and-socket joints rather than something as complex as universal joints containing adjustable pairs of angularcontact ball bearings. The answer is that ball-and-socket joints do not offer sufficient latitude to trade stiffness versus friction: the inevitable result of an attempt to make such a trade in a ball-and-socket joint is either too much backlash or too much friction. The universal joints are located at opposite ends of an axial subassembly that contains the load cell. The axial subassembly includes an axial shaft, an axial housing, and a fifth adjustable pair of angular-contact ball bearings that allows rotation of the axial housing relative to the shaft. The preload on each pair of angular-contact ball bearings can be adjusted to obtain the required stiffness with minimal friction, tailored for a specific application. The universal joint at each end affords two degrees of freedom, allowing only axial force to reach the load cell regardless of application of moments and non-axial forces. The rotational joint on the axial subassembly affords a fifth degree of freedom, preventing application of a torsion load to the load cell.

  5. A Subspace Approach to the Structural Decomposition and Identification of Ankle Joint Dynamic Stiffness.

    PubMed

    Jalaleddini, Kian; Tehrani, Ehsan Sobhani; Kearney, Robert E

    2017-06-01

    The purpose of this paper is to present a structural decomposition subspace (SDSS) method for decomposition of the joint torque to intrinsic, reflexive, and voluntary torques and identification of joint dynamic stiffness. First, it formulates a novel state-space representation for the joint dynamic stiffness modeled by a parallel-cascade structure with a concise parameter set that provides a direct link between the state-space representation matrices and the parallel-cascade parameters. Second, it presents a subspace method for the identification of the new state-space model that involves two steps: 1) the decomposition of the intrinsic and reflex pathways and 2) the identification of an impulse response model of the intrinsic pathway and a Hammerstein model of the reflex pathway. Extensive simulation studies demonstrate that SDSS has significant performance advantages over some other methods. Thus, SDSS was more robust under high noise conditions, converging where others failed; it was more accurate, giving estimates with lower bias and random errors. The method also worked well in practice and yielded high-quality estimates of intrinsic and reflex stiffnesses when applied to experimental data at three muscle activation levels. The simulation and experimental results demonstrate that SDSS accurately decomposes the intrinsic and reflex torques and provides accurate estimates of physiologically meaningful parameters. SDSS will be a valuable tool for studying joint stiffness under functionally important conditions. It has important clinical implications for the diagnosis, assessment, objective quantification, and monitoring of neuromuscular diseases that change the muscle tone.

  6. Assessment of passive knee stiffness and viscosity in individuals with spinal cord injury using pendulum test

    PubMed Central

    Joghtaei, Mahmoud; Arab, Amir Massoud; Hashemi-Nasl, Hamed; Joghataei, Mohammad Taghi; Tokhi, Mohammad Osman

    2015-01-01

    Objective Stiffness and viscosity represent passive resistances to joint motion related with the structural properties of the joint tissue and of the musculotendinous complex. Both parameters can be affected in patients with spinal cord injury (SCI). The purpose of this study was to measure passive knee stiffness and viscosity in patients with SCI with paraplegia and healthy subjects using Wartenberg pendulum test. Design Non-experimental, cross-sectional, case–control design. Setting An outpatient physical therapy clinic, University of social welfare and Rehabilitation Science, Iran. Patients A sample of convenience sample of 30 subjects participated in the study. Subjects were categorized into two groups: individuals with paraplegic SCI (n = 15, age: 34.60 ± 9.18 years) and 15 able-bodied individuals as control group (n = 15, age: 30.66 ± 11.13 years). Interventions Not applicable. Main measures Passive pendulum test of Wartenberg was used to measure passive viscous-elastic parameters of the knee (stiffness, viscosity) in all subjects. Results Statistical analysis (independent t-test) revealed significant difference in the joint stiffness between healthy subjects and those with paraplegic SCI (P = 0.01). However, no significant difference was found in the viscosity between two groups (P = 0.17). Except for first peak flexion angle, all other displacement kinematic parameters exhibited no statistically significant difference between normal subjects and subjects with SCI. Conclusions Patients with SCI have significantly greater joint stiffness compared to able-bodied subjects. PMID:25437824

  7. Treadmill training with an incline reduces ankle joint stiffness and improves active range of movement during gait in adults with cerebral palsy.

    PubMed

    Lorentzen, Jakob; Kirk, Henrik; Fernandez-Lago, Helena; Frisk, Rasmus; Scharff Nielsen, Nanna; Jorsal, Martin; Nielsen, Jens Bo

    2017-05-01

    We investigated if 30 min of daily treadmill training with an incline for 6 weeks would reduce ankle joint stiffness and improve active range of movement in adults with cerebral palsy (CP). The study was designed as a randomized controlled clinical trial including 32 adults with CP (GMFCS 1-3) aged 38.1 SD 12 years. The training group (n = 16) performed uphill treadmill training at home daily for 30 min for 6 weeks in addition to their usual activities. Passive and reflex mediated stiffness and range of motion (ROM) of the ankle joint, kinematic and functional measures of gait were obtained before and after the intervention/control period. Intervention subjects trained 31.4 SD 10.1 days for 29.0 SD 2.3 min (total) 15.2 h. Passive ankle joint stiffness was reduced (F = 5.1; p = 0.031), maximal gait speed increased (F = 42.8, p < 0.001), amplitude of toe lift prior to heel strike increased (F = 5.3, p < 0.03) and ankle angle at heel strike was decreased (F = 12.5; p < 0.001) significant in the training group as compared to controls. Daily treadmill training with an incline for 6 weeks reduces ankle joint stiffness and increases active ROM during gait in adults with CP. Intensive gait training may thus be beneficial in preventing and reducing contractures and help to maintain functional gait ability in adults with CP. Implications for rehabilitation Uphill gait training is an effective way to reduce ankle joint stiffness in adult with contractures. 6 weeks of daily uphill gait training improves functional gait parameters such as gait speed and dorsal flexion during gait in adults with cerebral palsy.

  8. Joining of Components of Complex Structures for Improved Dynamic Response

    DTIC Science & Technology

    2011-10-28

    system- level mass and stiffness matrices and force vector (at each frequency in the range of interest). To address this issue a series of complex...displacements of all candidate joint locations by using the system- level mass and stiffness matrices and force vector (at each frequency in the range of...joints. In contrast, Li et al. [10] proposed a fastener layout/topology that achieves an almost uniform stress level in each joint, and adopted

  9. Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

    NASA Technical Reports Server (NTRS)

    Verhage, Joseph M.; Bower, Mark V.; Gilbert, Paul A. (Technical Monitor)

    2001-01-01

    The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

  10. Model-Based Estimation of Knee Stiffness

    PubMed Central

    Pfeifer, Serge; Vallery, Heike; Hardegger, Michael; Riener, Robert; Perreault, Eric J.

    2013-01-01

    During natural locomotion, the stiffness of the human knee is modulated continuously and subconsciously according to the demands of activity and terrain. Given modern actuator technology, powered transfemoral prostheses could theoretically provide a similar degree of sophistication and function. However, experimentally quantifying knee stiffness modulation during natural gait is challenging. Alternatively, joint stiffness could be estimated in a less disruptive manner using electromyography (EMG) combined with kinetic and kinematic measurements to estimate muscle force, together with models that relate muscle force to stiffness. Here we present the first step in that process, where we develop such an approach and evaluate it in isometric conditions, where experimental measurements are more feasible. Our EMG-guided modeling approach allows us to consider conditions with antagonistic muscle activation, a phenomenon commonly observed in physiological gait. Our validation shows that model-based estimates of knee joint stiffness coincide well with experimental data obtained using conventional perturbation techniques. We conclude that knee stiffness can be accurately estimated in isometric conditions without applying perturbations, which presents an important step towards our ultimate goal of quantifying knee stiffness during gait. PMID:22801482

  11. Methodological considerations of task and shoe wear on joint energetics during landing.

    PubMed

    Shultz, Sandra J; Schmitz, Randy J; Tritsch, Amanda J; Montgomery, Melissa M

    2012-02-01

    To better understand methodological factors that alter landings strategies, we compared sagittal plane joint energetics during the initial landing phase of drop jumps (DJ) vs. drop landings (DL), and when shod vs. barefoot. Surface electromyography, kinematic and kinetic data were obtained on 10 males and 10 females during five consecutive drop landings and five consecutive drop jumps (0.45m) when shod and when barefoot. Energy absorption was greater in the DJ vs. DL (P=.002), due to increased energy absorption at the hip during the DJ. Joint stiffness/impedance was more affected by shoe condition, where overall stiffness/impedance was greater in shod compared to barefoot conditions (P=.036). Further, hip impedance was greater in shod vs. barefoot for the DL only (via increased peak hip extensor moment in DL), while ankle stiffness was greater in the barefoot vs. shod condition for the DJ only (via decreased joint excursion and increased peak joint moment in DJ vs. DL) (P=.011). DJ and DL place different neuromechanical demands upon the lower extremities, and shoe wear may alter impact forces that modulate stiffness/impedance strategies. The impact of these methodological differences should be considered when comparing landing biomechanics across studies. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Low-Intensity Vibration as a Treatment for Traumatic Muscle Injury

    DTIC Science & Technology

    2015-08-01

    improving muscle healing, thereby reducing joint stiffness and increasing mobility of polytrauma patients. 15. SUBJECT TERMS Skeletal muscle repair...mobility of polytrauma patients. 2. KEYWORDS Skeletal muscle repair, low-intensity vibration, monocytes/macrophages, endothelial precursor cells...innovative, non-invasive and simple treatment for improving muscle healing and thereby reducing joint stiffness and increasing mobility of polytrauma

  13. Contribution of knee flexor and extensor strength on sex-specific energy absorption and torsional joint stiffness during drop jumping.

    PubMed

    Schmitz, Randy J; Shultz, Sandra J

    2010-01-01

    Lower extremity injury often occurs during abrupt deceleration when attempting to change the body's direction. Although sex-specific biomechanics have been implicated in the greater risk of acute knee injury in women than in men, it is unknown if sex differences in thigh strength affect sex-specific energy absorption and torsional joint stiffness patterns. To determine sex differences in energy absorption patterns and joint stiffnesses of the lower extremity during a drop jump and to determine if these sex differences were predicted by knee extensor and flexor strength. Cross-sectional study. Laboratory environment. Recreationally active, college-aged students (41 women: age  =  22.1 ± 2.9 years, height  =  1.63 ± 0.07 m, mass  =  59.3 ± 8.0 kg; 40 men: age  =  22.4 ± 2.8 years, height  =  1.77 ± 0.1 m, mass  =  80.9 ± 14.1 kg). Participants performed knee flexor and extensor maximal voluntary isometric contractions followed by double-leg drop-jump landings. Lower extremity joint energetics (J × N(-1) × m(-1)) and torsional joint stiffnesses (Nm × N(-1) × m(-1) × degrees(-1)) were calculated for the hip, knee, and ankle during the initial landing phase. Body weight was measured in newtons and height was measured in meters. Sex comparisons were made and sex-specific regressions determined if thigh muscle strength (Nm/kg) predicted sagittal-plane landing energetics and stiffnesses. Women absorbed 69% more knee energy and had 36% less hip torsional stiffness than men. In women, greater knee extensor strength predicted greater knee energy absorption (R(2)  =  0.11, P  =  .04), and greater knee flexor strength predicted greater hip torsional stiffness (R(2)  =  0.12, P  =  .03). Sex-specific biomechanics during the deceleration phase of a drop jump revealed that women used a strategy to attempt to decrease system stiffness. Additionally, only female strength values were predictive of landing energetics and stiffnesses. These findings collectively demonstrated that the task may have been more difficult for women, resulting in a different movement strategy among those with different levels of thigh strength to safely complete the task. Future researchers should look at other predictive factors of observed sex differences.

  14. Anti-buckling design of variable stiffness composite cylinder under combined loading based on the multi-objective optimization method

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Chen, J.

    2018-06-01

    Variable stiffness composite structures take full advantages of composite’s design ability. An enlarged design space will make the structure’s performance more excellent. Through an optimal design of a variable stiffness cylinder, the buckling capacity of the cylinder will be increased as compared with its constant stiffness counterpart. In this paper, variable stiffness composite cylinders sustaining combined loadings are considered, and the optimization is conducted based on the multi-objective optimization method. The results indicate that variable stiffness cylinder’s loading capacity is increased significantly as compared with the constant stiffness, especially when an inhomogeneous loading is considered.

  15. Mechanical behaviour of hamstring muscles in low-back pain patients and control subjects.

    PubMed

    Tafazzoli, F; Lamontagne, M

    1996-01-01

    The purpose of this study was to measure and compare the passive elastic moment, the stiffness and the damping coefficient of the hip joint, as functions of the hip and knee joint angles in men with and without low-back pain. Two conventional tests, the straight-leg-raising test and the trunk forward flexion, were also performed and compared between these subjects. The passive elastic moment was measured using an isokinetic device in the passive mode. This device raised the lower limb from the horizontal position to the straight-leg-raising angle at a slow and constant angular velocity. A custom-made splint connected with the lever arm of the isokinetic device maintained the knee in extension and the ankle in the neutral position. The damping coefficient of the hip joint was measured for 0, 15, 45, 60, 75 and 90% of straight leg raising angle of each subject, using the suspension method based on small oscillation theory. To ensure that muscles were inactive during the passive hip moment tests, muscle activity was monitored with surface EMG. The stiffness was computed as the ratio of the change in passive elastic moment to the change in the hip angle. The passive elastic moment, the stiffness and the normalized trunk flexion were significantly different between the two groups respectively. There was, however, no difference between the two groups in the results of straight-leg-raise and damping coefficient of the hip. The passive elastic moment was a nonlinear function of the hip flexion angle and showed large intersubject differences, especially as the joint limit was approached. The damping coefficient was a polynomial function of the hip flexion angle. The measured variables were analysed using a discriminant function and it was shown that the two groups were clearly discriminable in a meaningful manner.

  16. Endpoint Accuracy in Manual Control of a Steerable Needle.

    PubMed

    van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-02-01

    To study the ability of a human operator to manually correct for errors in the needle insertion path without partial withdrawal of the needle by means of an active, tip-articulated steerable needle. The needle is composed of a 1.32-mm outer-diameter cannula, with a flexure joint near the tip, and a retractable stylet. The bending stiffness of the needle resembles that of a 20-gauge hypodermic needle. The needle functionality was evaluated in manual insertions by steering to predefined targets and a lateral displacement of 20 mm from the straight insertion line. Steering tasks were conducted in 5 directions and 2 tissue simulants under image guidance from a camera. The repeatability in instrument actuations was assessed during 100 mm deep automated insertions with a linear motor. In addition to tip position, tip angles were tracked during the insertions. The targeting error (mean absolute error ± standard deviation) during manual steering to 5 different targets in stiff tissue was 0.5 mm ± 1.1. This variability in manual tip placement (1.1 mm) was less than the variability among automated insertions (1.4 mm) in the same tissue type. An increased tissue stiffness resulted in an increased lateral tip displacement. The tip angle was directly controlled by the user interface, and remained unaffected by the tissue stiffness. This study demonstrates the ability to manually steer needles to predefined target locations under image guidance. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  17. On the Origin of Muscle Synergies: Invariant Balance in the Co-activation of Agonist and Antagonist Muscle Pairs

    PubMed Central

    Hirai, Hiroaki; Miyazaki, Fumio; Naritomi, Hiroaki; Koba, Keitaro; Oku, Takanori; Uno, Kanna; Uemura, Mitsunori; Nishi, Tomoki; Kageyama, Masayuki; Krebs, Hermano Igo

    2015-01-01

    Investigation of neural representation of movement planning has attracted the attention of neuroscientists, as it may reveal the sensorimotor transformation essential to motor control. The analysis of muscle synergies based on the activity of agonist–antagonist (AA) muscle pairs may provide insight into such transformations, especially for a reference frame in the muscle space. In this study, we examined the AA concept using the following explanatory variables: the AA ratio, which is related to the equilibrium-joint angle, and the AA sum, which is associated with joint stiffness. We formulated muscle synergies as a function of AA sums, positing that muscle synergies are composite units of mechanical impedance. The AA concept can be regarded as another form of the equilibrium-point (EP) hypothesis, and it can be extended to the concept of EP-based synergies. We introduce, here, a novel tool for analyzing the neurological and motor functions underlying human movements and review some initial insights from our results about the relationships between muscle synergies, endpoint stiffness, and virtual trajectories (time series of EP). Our results suggest that (1) muscle synergies reflect an invariant balance in the co-activation of AA muscle pairs; (2) each synergy represents the basis for the radial, tangential, and null movements of the virtual trajectory in the polar coordinates centered on the specific joint at the base of the body; and (3) the alteration of muscle synergies (for example, due to spasticity or rigidity following neurological injury) results in significant distortion of endpoint stiffness and concomitant virtual trajectories. These results indicate that muscle synergies (i.e., the balance of muscle mechanical impedance) are essential for motor control. PMID:26636079

  18. On the Origin of Muscle Synergies: Invariant Balance in the Co-activation of Agonist and Antagonist Muscle Pairs.

    PubMed

    Hirai, Hiroaki; Miyazaki, Fumio; Naritomi, Hiroaki; Koba, Keitaro; Oku, Takanori; Uno, Kanna; Uemura, Mitsunori; Nishi, Tomoki; Kageyama, Masayuki; Krebs, Hermano Igo

    2015-01-01

    Investigation of neural representation of movement planning has attracted the attention of neuroscientists, as it may reveal the sensorimotor transformation essential to motor control. The analysis of muscle synergies based on the activity of agonist-antagonist (AA) muscle pairs may provide insight into such transformations, especially for a reference frame in the muscle space. In this study, we examined the AA concept using the following explanatory variables: the AA ratio, which is related to the equilibrium-joint angle, and the AA sum, which is associated with joint stiffness. We formulated muscle synergies as a function of AA sums, positing that muscle synergies are composite units of mechanical impedance. The AA concept can be regarded as another form of the equilibrium-point (EP) hypothesis, and it can be extended to the concept of EP-based synergies. We introduce, here, a novel tool for analyzing the neurological and motor functions underlying human movements and review some initial insights from our results about the relationships between muscle synergies, endpoint stiffness, and virtual trajectories (time series of EP). Our results suggest that (1) muscle synergies reflect an invariant balance in the co-activation of AA muscle pairs; (2) each synergy represents the basis for the radial, tangential, and null movements of the virtual trajectory in the polar coordinates centered on the specific joint at the base of the body; and (3) the alteration of muscle synergies (for example, due to spasticity or rigidity following neurological injury) results in significant distortion of endpoint stiffness and concomitant virtual trajectories. These results indicate that muscle synergies (i.e., the balance of muscle mechanical impedance) are essential for motor control.

  19. Low Intensity Vibration as a Treatment for Traumatic Muscle Injury

    DTIC Science & Technology

    2016-08-01

    improving muscle healing, thereby reducing joint stiffness and increasing mobility of polytrauma patients. 15. SUBJECT TERMS Skeletal muscle repair...and increasing mobility of polytrauma patients. 2. KEYWORDS Skeletal muscle repair, low-intensity vibration, monocytes/macrophages, endothelial...reducing joint stiffness and increasing mobility of polytrauma patients. 11 What was the impact on other disciplines? Nothing to report What was

  20. Mechanical model of suture joints with fibrous connective layer

    NASA Astrophysics Data System (ADS)

    Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning

    2018-02-01

    A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.

  1. Neural Network Optimization of Ligament Stiffnesses for the Enhanced Predictive Ability of a Patient-Specific, Computational Foot/Ankle Model.

    PubMed

    Chande, Ruchi D; Wayne, Jennifer S

    2017-09-01

    Computational models of diarthrodial joints serve to inform the biomechanical function of these structures, and as such, must be supplied appropriate inputs for performance that is representative of actual joint function. Inputs for these models are sourced from both imaging modalities as well as literature. The latter is often the source of mechanical properties for soft tissues, like ligament stiffnesses; however, such data are not always available for all the soft tissues nor is it known for patient-specific work. In the current research, a method to improve the ligament stiffness definition for a computational foot/ankle model was sought with the greater goal of improving the predictive ability of the computational model. Specifically, the stiffness values were optimized using artificial neural networks (ANNs); both feedforward and radial basis function networks (RBFNs) were considered. Optimal networks of each type were determined and subsequently used to predict stiffnesses for the foot/ankle model. Ultimately, the predicted stiffnesses were considered reasonable and resulted in enhanced performance of the computational model, suggesting that artificial neural networks can be used to optimize stiffness inputs.

  2. Acute effects of static stretching on passive stiffness of the hamstring muscles calculated using different mathematical models.

    PubMed

    Nordez, Antoine; Cornu, Christophe; McNair, Peter

    2006-08-01

    The aim of this study was to assess the effects of static stretching on hamstring passive stiffness calculated using different data reduction methods. Subjects performed a maximal range of motion test, five cyclic stretching repetitions and a static stretching intervention that involved five 30-s static stretches. A computerised dynamometer allowed the measurement of torque and range of motion during passive knee extension. Stiffness was then calculated as the slope of the torque-angle relationship fitted using a second-order polynomial, a fourth-order polynomial, and an exponential model. The second-order polynomial and exponential models allowed the calculation of stiffness indices normalized to knee angle and passive torque, respectively. Prior to static stretching, stiffness levels were significantly different across the models. After stretching, while knee maximal joint range of motion increased, stiffness was shown to decrease. Stiffness decreased more at the extended knee joint angle, and the magnitude of change depended upon the model used. After stretching, the stiffness indices also varied according to the model used to fit data. Thus, the stiffness index normalized to knee angle was found to decrease whereas the stiffness index normalized to passive torque increased after static stretching. Stretching has significant effects on stiffness, but the findings highlight the need to carefully assess the effect of different models when analyzing such data.

  3. Mechanics of Suture Joints

    NASA Astrophysics Data System (ADS)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  4. Human-like Compliance for Dexterous Robot Hands

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.

    1995-01-01

    This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.

  5. Development of safe mechanism for surgical robots using equilibrium point control method.

    PubMed

    Park, Shinsuk; Lim, Hokjin; Kim, Byeong-sang; Song, Jae-bok

    2006-01-01

    This paper introduces a novel mechanism for surgical robotic systems to generate human arm-like compliant motion. The mechanism is based on the idea of the equilibrium point control hypothesis which claims that multi-joint limb movements are achieved by shifting the limbs' equilibrium positions defined by neuromuscular activity. The equilibrium point control can be implemented on a robot manipulator by installing two actuators at each joint of the manipulator, one to control the joint position, and the other to control the joint stiffness. This double-actuator mechanism allows us to arbitrarily manipulate the stiffness (or impedance) of a robotic manipulator as well as its position. Also, the force at the end-effector can be estimated based on joint stiffness and joint angle changes without using force transducers. A two-link manipulator and a three-link manipulator with the double-actuator units have been developed, and experiments and simulation results show the potential of the proposed approach. By creating the human arm-like behavior, this mechanism can improve the performance of robot manipulators to execute stable and safe movement in surgical environments by using a simple control scheme.

  6. Quantifying in vivo laxity in the anterior cruciate ligament and individual knee joint structures.

    PubMed

    Westover, L M; Sinaei, N; Küpper, J C; Ronsky, J L

    2016-11-01

    A custom knee loading apparatus (KLA), when used in conjunction with magnetic resonance imaging, enables in vivo measurement of the gross anterior laxity of the knee joint. A numerical model was applied to the KLA to understand the contribution of the individual joint structures and to estimate the stiffness of the anterior-cruciate ligament (ACL). The model was evaluated with a cadaveric study using an in situ knee loading apparatus and an ElectroForce test system. A constrained optimization solution technique was able to predict the restraining forces within the soft-tissue structures and joint contact. The numerical model presented here allowed in vivo prediction of the material stiffness parameters of the ACL in response to applied anterior loading. Promising results were obtained for in vivo load sharing within the structures. The numerical model overestimated the ACL forces by 27.61-92.71%. This study presents a novel approach to estimate ligament stiffness and provides the basis to develop a robust and accurate measure of in vivo knee joint laxity.

  7. Model-Based Estimation of Ankle Joint Stiffness

    PubMed Central

    Misgeld, Berno J. E.; Zhang, Tony; Lüken, Markus J.; Leonhardt, Steffen

    2017-01-01

    We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model’s inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements. PMID:28353683

  8. Increased vertical impact forces and altered running mechanics with softer midsole shoes.

    PubMed

    Baltich, Jennifer; Maurer, Christian; Nigg, Benno M

    2015-01-01

    To date it has been thought that shoe midsole hardness does not affect vertical impact peak forces during running. This conclusion is based partially on results from experimental data using homogeneous samples of participants that found no difference in vertical impact peaks when running in shoes with different midsole properties. However, it is currently unknown how apparent joint stiffness is affected by shoe midsole hardness. An increase in apparent joint stiffness could result in a harder landing, which should result in increased vertical impact peaks during running. The purpose of this study was to quantify the effect of shoe midsole hardness on apparent ankle and knee joint stiffness and the associated vertical ground reaction force for age and sex subgroups during heel-toe running. 93 runners (male and female) aged 16-75 years ran at 3.33 ± 0.15 m/s on a 30 m-long runway with soft, medium and hard midsole shoes. The vertical impact peak increased as the shoe midsole hardness decreased (mean(SE); soft: 1.70BW(0.03), medium: 1.64BW(0.03), hard: 1.54BW(0.03)). Similar results were found for the apparent ankle joint stiffness where apparent stiffness increased as the shoe midsole hardness decreased (soft: 2.08BWm/º x 100 (0.05), medium: 1.92 BWm/º x 100 (0.05), hard: 1.85 BWm/º x 100 (0.05)). Apparent knee joint stiffness increased for soft (1.06BWm/º x 100 (0.04)) midsole compared to the medium (0.95BWm/º x 100 (0.04)) and hard (0.96BWm/º x 100 (0.04)) midsoles for female participants. The results from this study confirm that shoe midsole hardness can have an effect on vertical impact force peaks and that this may be connected to the hardness of the landing. The results from this study may provide useful information regarding the development of cushioning guidelines for running shoes.

  9. Increased Vertical Impact Forces and Altered Running Mechanics with Softer Midsole Shoes

    PubMed Central

    Baltich, Jennifer; Maurer, Christian; Nigg, Benno M.

    2015-01-01

    To date it has been thought that shoe midsole hardness does not affect vertical impact peak forces during running. This conclusion is based partially on results from experimental data using homogeneous samples of participants that found no difference in vertical impact peaks when running in shoes with different midsole properties. However, it is currently unknown how apparent joint stiffness is affected by shoe midsole hardness. An increase in apparent joint stiffness could result in a harder landing, which should result in increased vertical impact peaks during running. The purpose of this study was to quantify the effect of shoe midsole hardness on apparent ankle and knee joint stiffness and the associated vertical ground reaction force for age and sex subgroups during heel-toe running. 93 runners (male and female) aged 16-75 years ran at 3.33 ± 0.15 m/s on a 30 m-long runway with soft, medium and hard midsole shoes. The vertical impact peak increased as the shoe midsole hardness decreased (mean(SE); soft: 1.70BW(0.03), medium: 1.64BW(0.03), hard: 1.54BW(0.03)). Similar results were found for the apparent ankle joint stiffness where apparent stiffness increased as the shoe midsole hardness decreased (soft: 2.08BWm/º x 100 (0.05), medium: 1.92 BWm/º x 100 (0.05), hard: 1.85 BWm/º x 100 (0.05)). Apparent knee joint stiffness increased for soft (1.06BWm/º x 100 (0.04)) midsole compared to the medium (0.95BWm/º x 100 (0.04)) and hard (0.96BWm/º x 100 (0.04)) midsoles for female participants. The results from this study confirm that shoe midsole hardness can have an effect on vertical impact force peaks and that this may be connected to the hardness of the landing. The results from this study may provide useful information regarding the development of cushioning guidelines for running shoes. PMID:25897963

  10. Effect of Reduced Stiffness Dance Flooring on Lower Extremity Joint Angular Trajectories During a Ballet Jump.

    PubMed

    Hackney, James; Brummel, Sara; Newman, Mary; Scott, Shannon; Reinagel, Matthew; Smith, Jennifer

    2015-09-01

    We carried out a study to investigate how low stiffness flooring may help prevent overuse injuries of the lower extremity in dancers. It was hypothesized that performing a ballet jump (sauté) on a reduced stiffness dance floor would decrease maximum joint flexion angles and negative angular velocities at the hips, knees, or ankles compared to performing the same jump on a harder floor. The participants were 15 young adult female dancers (age range 18 to 28, mean = 20.89 ± 2.93 years) with at least 5 years of continuous ballet experience and without history of serious lower body injury, surgery, or recent pain. They performed sautés on a (low stiffness) Harlequin ® WoodSpring Floor and on a vinyl-covered hardwood on concrete floor. Maximum joint flexion angles and negative velocities at bilateral hips, knees, and ankles were measured with the "Ariel Performance Analysis System" (APAS). Paired one-tailed t-tests yielded significant decreases in maximum knee angle (average decrease = 3.4° ± 4.2°, p = 0.026) and angular negative velocity of the ankles (average decrease = 18.7°/sec ± 27.9°/sec, p = 0.009) with low stiffness flooring. If the knee angle is less acute, then the length of the external knee flexion moment arm will also be shorter and result in a smaller external knee flexion moment, given an equal landing force. Also, high velocities of eccentric muscle contraction, which are necessary to control negative angular velocity of the ankle joint, are associated with higher risk of musculotendinous injury. Hence, our findings indicate that reduced floor stiffness may indeed help decrease the likelihood of lower extremity injuries.

  11. Contribution of Knee Flexor and Extensor Strength on Sex-Specific Energy Absorption and Torsional Joint Stiffness During Drop Jumping

    PubMed Central

    Schmitz, Randy J.; Shultz, Sandra J.

    2010-01-01

    Abstract Context: Lower extremity injury often occurs during abrupt deceleration when attempting to change the body's direction. Although sex-specific biomechanics have been implicated in the greater risk of acute knee injury in women than in men, it is unknown if sex differences in thigh strength affect sex-specific energy absorption and torsional joint stiffness patterns. Objective: To determine sex differences in energy absorption patterns and joint stiffnesses of the lower extremity during a drop jump and to determine if these sex differences were predicted by knee extensor and flexor strength. Design: Cross-sectional study. Setting: Laboratory environment. Patients or Other Participants: Recreationally active, college-aged students (41 women: age  =  22.1 ± 2.9 years, height  =  1.63 ± 0.07 m, mass  =  59.3 ± 8.0 kg; 40 men: age  =  22.4 ± 2.8 years, height  =  1.77 ± 0.1 m, mass  =  80.9 ± 14.1 kg). Intervention(s): Participants performed knee flexor and extensor maximal voluntary isometric contractions followed by double-leg drop-jump landings. Main Outcome Measure(s): Lower extremity joint energetics (J × N−1 × m−1) and torsional joint stiffnesses (Nm × N−1 × m−1 × degrees−1) were calculated for the hip, knee, and ankle during the initial landing phase. Body weight was measured in newtons and height was measured in meters. Sex comparisons were made and sex-specific regressions determined if thigh muscle strength (Nm/kg) predicted sagittal-plane landing energetics and stiffnesses. Results: Women absorbed 69% more knee energy and had 36% less hip torsional stiffness than men. In women, greater knee extensor strength predicted greater knee energy absorption (R2  =  0.11, P  =  .04), and greater knee flexor strength predicted greater hip torsional stiffness (R2  =  0.12, P  =  .03). Conclusions: Sex-specific biomechanics during the deceleration phase of a drop jump revealed that women used a strategy to attempt to decrease system stiffness. Additionally, only female strength values were predictive of landing energetics and stiffnesses. These findings collectively demonstrated that the task may have been more difficult for women, resulting in a different movement strategy among those with different levels of thigh strength to safely complete the task. Future researchers should look at other predictive factors of observed sex differences. PMID:20831388

  12. Joint stability characteristics of the ankle complex in female athletes with histories of lateral ankle sprain, part II: clinical experience using arthrometric measurement.

    PubMed

    Kovaleski, John E; Heitman, Robert J; Gurchiek, Larry R; Hollis, J M; Liu, Wei; Pearsall, Albert W

    2014-01-01

    This is part II of a 2-part series discussing stability characteristics of the ankle complex. In part I, we used a cadaver model to examine the effects of sectioning the lateral ankle ligaments on anterior and inversion motion and stiffness of the ankle complex. In part II, we wanted to build on and apply these findings to the clinical assessment of ankle-complex motion and stiffness in a group of athletes with a history of unilateral ankle sprain. To examine ankle-complex motion and stiffness in a group of athletes with reported history of lateral ankle sprain. Cross-sectional study. University research laboratory. Twenty-five female college athletes (age = 19.4 ± 1.4 years, height = 170.2 ± 7.4 cm, mass = 67.3 ± 10.0 kg) with histories of unilateral ankle sprain. All ankles underwent loading with an ankle arthrometer. Ankles were tested bilaterally. The dependent variables were anterior displacement, anterior end-range stiffness, inversion rotation, and inversion end-range stiffness. Anterior displacement of the ankle complex did not differ between the uninjured and sprained ankles (P = .37), whereas ankle-complex rotation was greater for the sprained ankles (P = .03). The sprained ankles had less anterior and inversion end-range stiffness than the uninjured ankles (P < .01). Changes in ankle-complex laxity and end-range stiffness were detected in ankles with histories of sprain. These results indicate the presence of altered mechanical characteristics in the soft tissues of the sprained ankles.

  13. Optimal lay-up design of variable stiffness laminated composite plates by a layer-wise optimization technique

    NASA Astrophysics Data System (ADS)

    Houmat, A.

    2018-02-01

    The optimal lay-up design for the maximum fundamental frequency of variable stiffness laminated composite plates is investigated using a layer-wise optimization technique. The design variables are two fibre orientation angles per ply. Thin plate theory is used in conjunction with a p-element to calculate the fundamental frequencies of symmetrically and antisymmetrically laminated composite plates. Comparisons with existing optimal solutions for constant stiffness symmetrically laminated composite plates show excellent agreement. It is observed that the maximum fundamental frequency can be increased considerably using variable stiffness design as compared to constant stiffness design. In addition, optimal lay-ups for the maximum fundamental frequency of variable stiffness symmetrically and antisymmetrically laminated composite plates with different aspect ratios and various combinations of free, simply supported and clamped edge conditions are presented. These should prove a useful benchmark for optimal lay-ups of variable stiffness laminated composite plates.

  14. Effects of repeated ankle stretching on calf muscle-tendon and ankle biomechanical properties in stroke survivors

    PubMed Central

    Gao, Fan; Ren, Yupeng; Roth, Elliot J.; Harvey, Richard; Zhang, Li-Qun

    2011-01-01

    Background The objective of this study was to investigate changes in active and passive biomechanical properties of the calf muscle-tendon unit induced by controlled ankle stretching in stroke survivors. Methods Ten stroke survivors with ankle spasticity/contracture and ten healthy control subjects received intervention of 60-min ankle stretching. Joint biomechanical properties including resistance torque, stiffness and index of hysteresis were evaluated pre- and post-intervention. Achilles tendon length was measured using ultrasonography. The force output of the triceps surae muscles was characterized via the torque-angle relationship, by stimulating the calf muscles at a controlled intensity across different ankle positions. Findings Compared to healthy controls, the ankle position corresponding to the peak torque of the stroke survivors was shifted towards plantar flexion (P<0.001). Stroke survivors showed significantly higher resistance torques and joint stiffness (P<0.05), and these higher resistances were reduced significantly after the stretching intervention, especially in dorsiflexion (P = 0.013). Stretching significantly improved the force output of the impaired calf muscles in stroke survivors under matched stimulations (P<0.05). Ankle range of motion was also increased by stretching (P<0.001). Interpretation At the joint level, repeated stretching loosened the ankle joint with increased passive joint range of motion and decreased joint stiffness. At the muscle-tendon level, repeated stretching improved calf muscle force output, which might be associated with decreased muscle fascicle stiffness, increased fascicle length and shortening of the Achilles tendon. The study provided evidence of improvement in muscle tendon properties through stretching intervention. PMID:21211873

  15. Impact attenuation properties of jazz shoes alter lower limb joint stiffness during jump landings.

    PubMed

    Fong Yan, Alycia; Smith, Richard M; Hiller, Claire E; Sinclair, Peter J

    2017-05-01

    To quantify the impact attenuation properties of the jazz shoes, and to investigate the in-vivo effect of four jazz shoe designs on lower limb joint stiffness during a dance-specific jump. Repeated measures. A custom-built mechanical shoe tester similar to that used by athletic shoe companies was used to vertically impact the forefoot and heel region of four different jazz shoe designs. Additionally, dancers performed eight sautés in second position in bare feet and the shoe conditions. Force platforms and 3D-motion capture were used to analyse the joint stiffness of the midfoot, ankle, knee and hip during the jump landings. Mechanical testing of the jazz shoes revealed significant differences in impact attenuation characteristics among each of the jazz shoe designs. Gross knee and midfoot joint stiffness were significantly affected by the jazz shoe designs in the dancers' jump landings. The tested jazz shoe designs altered the impact attenuating capacity of jump landing technique in dancers. The cushioned jazz shoes are recommended particularly for injured dancers to reduce impact on the lower limb. Jazz shoe design should consider the impact attenuation properties of the forefoot region, due to the toe-strike landing technique in dance movement. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Self-aligning exoskeleton hip joint: Kinematic design with five revolute, three prismatic and one ball joint.

    PubMed

    Beil, Jonas; Marquardt, Charlotte; Asfour, Tamim

    2017-07-01

    Kinematic compatibility is of paramount importance in wearable robotic and exoskeleton design. Misalignments between exoskeletons and anatomical joints of the human body result in interaction forces which make wearing the exoskeleton uncomfortable and even dangerous for the human. In this paper we present a kinematically compatible design of an exoskeleton hip to reduce kinematic incompatibilities, so called macro- and micro-misalignments, between the human's and exoskeleton's joint axes, which are caused by inter-subject variability and articulation. The resulting design consists of five revolute, three prismatic and one ball joint. Design parameters such as range of motion and joint velocities are calculated based on the analysis of human motion data acquired by motion capture systems. We show that the resulting design is capable of self-aligning to the human hip joint in all three anatomical planes during operation and can be adapted along the dorsoventral and mediolateral axis prior to operation. Calculation of the forward kinematics and FEM-simulation considering kinematic and musculoskeletal constraints proved sufficient mobility and stiffness of the system regarding the range of motion, angular velocity and torque admissibility needed to provide 50 % assistance for an 80 kg person.

  17. On the stiffness matrix of the intervertebral joint: application to total disk replacement.

    PubMed

    O'Reilly, Oliver M; Metzger, Melodie F; Buckley, Jenni M; Moody, David A; Lotz, Jeffrey C

    2009-08-01

    The traditional method of establishing the stiffness matrix associated with an intervertebral joint is valid only for infinitesimal rotations, whereas the rotations featured in spinal motion are often finite. In the present paper, a new formulation of this stiffness matrix is presented, which is valid for finite rotations. This formulation uses Euler angles to parametrize the rotation, an associated basis, which is known as the dual Euler basis, to describe the moments, and it enables a characterization of the nonconservative nature of the joint caused by energy loss in the poroviscoelastic disk and ligamentous support structure. As an application of the formulation, the stiffness matrix of a motion segment is experimentally determined for the case of an intact intervertebral disk and compared with the matrices associated with the same segment after the insertion of a total disk replacement system. In this manner, the matrix is used to quantify the changes in the intervertebral kinetics associated with total disk replacements. As a result, this paper presents the first such characterization of the kinetics of a total disk replacement.

  18. Measurement of passive ankle stiffness in subjects with chronic hemiparesis using a novel ankle robot

    PubMed Central

    Roy, Anindo; Bever, Christopher T.; Forrester, Larry W.; Macko, Richard F.; Hogan, Neville

    2011-01-01

    Our objective in this study was to assess passive mechanical stiffness in the ankle of chronic hemiparetic stroke survivors and to compare it with those of healthy young and older (age-matched) individuals. Given the importance of the ankle during locomotion, an accurate estimate of passive ankle stiffness would be valuable for locomotor rehabilitation, potentially providing a measure of recovery and a quantitative basis to design treatment protocols. Using a novel ankle robot, we characterized passive ankle stiffness both in sagittal and in frontal planes by applying perturbations to the ankle joint over the entire range of motion with subjects in a relaxed state. We found that passive stiffness of the affected ankle joint was significantly higher in chronic stroke survivors than in healthy adults of a similar cohort, both in the sagittal as well as frontal plane of movement, in three out of four directions tested with indistinguishable stiffness values in plantarflexion direction. Our findings are comparable to the literature, thus indicating its plausibility, and, to our knowledge, report for the first time passive stiffness in the frontal plane for persons with chronic stroke and older healthy adults. PMID:21346215

  19. A novel variable stiffness mechanism for dielectric elastomer actuators

    NASA Astrophysics Data System (ADS)

    Li, Wen-Bo; Zhang, Wen-Ming; Zou, Hong-Xiang; Peng, Zhi-Ke; Meng, Guang

    2017-08-01

    In this paper, a novel variable stiffness mechanism is proposed for the design of a variable stiffness dielectric elastomer actuator (VSDEA) which combines a flexible strip with a DEA in a dielectric elastomer minimum energy structure. The DEA induces an analog tuning of the transverse curvature of the strip, thus conveniently providing a voltage-controllable flexural rigidity. The VSDEA tends to be a fully flexible and compact structure with the advantages of simplicity and fast response. Both experimental and theoretical investigations are carried out to reveal the variable stiffness performances of the VSDEA. The effect of the clamped location on the bending stiffness of the VSDEA is analyzed, and then effects of the lengths, the loading points and the applied voltages on the bending stiffness are experimentally investigated. An analytical model is developed to verify the availability of this variable stiffness mechanism, and the theoretical results demonstrate that the bending stiffness of the VSDEA decreases as the applied voltage increases, which agree well with the experimental data. Moreover, the experimental results show that the maximum change of the relative stiffness can reach about 88.80%. It can be useful for the design and optimization of active variable stiffness structures and DEAs for soft robots, vibration control, and morphing applications.

  20. Structural Mechanics Solutions for Butt Joint Seals in Cold Climates

    DOT National Transportation Integrated Search

    1996-08-01

    An effective, formed-in-place joint seal will respond with elastic or viscoelastic behavior over a reasonable design life to any large movement of the joint without adhesive or cohesive failure. For a given joint movement, seals with lower stiffness ...

  1. Biomechanical Evaluation of a Prototype Foot/Ankle Prosthesis

    PubMed Central

    Quesada, P. M.; Pitkin, M.; Colvin, J.

    2016-01-01

    In this paper, we report on our pilot evaluation of a prototype foot/ankle prosthesis. This prototype has been designed and fabricated with the intention of providing decreased ankle joint stiffness during the middle portion of the stance phase of gait, and increased (i.e., more normal) knee range of motion during stance. Our evaluation involved fitting the existing prototype foot/ankle prosthesis, as well as a traditional solid ankle cushioned heel (SACH) foot, to an otherwise healthy volunteer with a below-knee (BK) amputation. We measured this individual’s lower extremity joint kinematics and kinetics during walking using a video motion analysis system and force platform. These measurements permitted direct comparison of prosthetic ankle joint stiffness and involved side knee joint motion, as well as prosthetic ankle joint moment and power. PMID:10779119

  2. Fluid flow analysis of E-glass fiber reinforced pipe joints in oil and gas industry

    NASA Astrophysics Data System (ADS)

    Bobba, Sujith; Leman, Z.; Zainuddin, E. S.; Sapuan, S. M.

    2018-04-01

    Glass Fiber reinforced composites have become increasingly important over the past few years and now they are the first choice materials for fabricating pipes with low weight in combination with high strength and stiffness. In Oil And Gas Industry, The Pipelines transporting heavy crude oil are subjected to variable pressure waves causing fluctuating stress levels in the pipes. Computational Fluid Dynamics (CFD) analysis was performed using solid works flow stimulation software to study the effects of these pressure waves on some specified joints in the pipes. Depending on the type of heavy crude oil being used, the flow behavior indicated a considerable degree of stress levels in certain connecting joints, causing the joints to become weak over a prolonged period of use. This research proposes a new perspective that is still required to be developed regarding the change of the pipe material, fiber winding angle in those specified joints and finally implementing cad wind technology to check the output result of the stress levels so that the life of the pipes can be optimized.

  3. Variable stiffness mechanisms with SMA actuators

    NASA Astrophysics Data System (ADS)

    Siler, Damin J.; Demoret, Kimberly B. J.

    1996-05-01

    Variable stiffness is a new branch of smart structures development with several applications related to aircraft. Previous research indicates that temporarily reducing the stiffness of an airplane wing can decrease control actuator sizing and improve aeroelastic roll performance. Some smart materials like shape memory alloys (SMA) can change their material stiffness properties, but they tend to gain stiffness in their `power on' state. An alternative is to integrate mechanisms into a structure and change stiffness by altering boundary conditions and structural load paths. An innovative concept for an axial strut mechanism was discovered as part of research into variable stiffness. It employs SMA springs (specifically Ni-Ti) in a way that reduces overall stiffness when the SMA springs gain stiffness. A simplified mathematical model for static analysis was developed, and a 70% reduction in stiffness was obtained for a particular selection of springs. The small force capacity of commercially available SMA springs limits the practicality of this concept for large load applications. However, smart material technology is still immature, and future advances may permit development of a heavy-duty, variable stiffness strut that is small and light enough for use in aircraft structures.

  4. Reconstruction of equilibrium trajectories and joint stiffness patterns during single-joint voluntary movements under different instructions.

    PubMed

    Latash, M L

    1994-01-01

    A method for reconstructing joint compliant characteristics during voluntary movements was applied to the analysis of oscillatory and unidirectional elbow flexion movements. In different series, the subjects were given one of the following instructions: (1) do not intervene voluntarily; (2) keep the trajectory; (3) in cases of perturbations, return back to the starting position as quickly as possible (only during unidirectional movements). Under the instruction 'keep trajectory', the apparent joint stiffness increased by 50% to 250%. During oscillatory movements, this was accompanied by a decrease in the maximal difference between the actual and equilibrium joint trajectories and, in several cases, led to a change in the phase relation between the two trajectories. The coefficients of correlation between joint torque and angle were very high (commonly, over 0.9) under the 'do not intervene' instruction. They dropped to about 0.6 under the 'keep trajectory' and to about 0.3 under the 'return back' instructions. Under these two instructions, the low values of the coefficients of correlation did not allow reconstruction of segments of equilibrium trajectories and joint stiffness values in all the subjects. The results provide further support for the lambda-version of the equilibrium-point hypothesis and for using the instruction 'do not intervene voluntarily' to obtain reproducible time patterns of the central motor command.

  5. Bee venom acupuncture for rheumatoid arthritis: a systematic review of randomised clinical trials.

    PubMed

    Lee, Ju Ah; Son, Mi Ju; Choi, Jiae; Jun, Ji Hee; Kim, Jong-In; Lee, Myeong Soo

    2014-11-07

    To assess the clinical evidence for bee venom acupuncture (BVA) for rheumatoid arthritis (RA). Systematic review of randomised controlled trials (RCTs). We searched 14 databases up to March 2014 without a language restriction. Patients with RA. BVA involved injecting purified, diluted BV into acupoints. We included trials on BVA used alone or in combination with a conventional therapy versus the conventional therapy alone. Morning stiffness, pain and joint swelling Erythrocyte sedimentation rate (ESR), C reactive protein (CRP), rheumatoid factor, the number of joints affected by RA and adverse effects likely related to RA. A total of 304 potentially relevant studies were identified; only one RCT met our inclusion criteria. Compared with placebo, BVA may more effectively improve joint pain, swollen joint counts, tender joint counts, ESR and CRP but was not shown to improve morning stiffness. There is low-quality evidence, based on one trial, that BVA can significantly reduce pain, morning stiffness, tender joint counts, swollen joint counts and improve the quality of life of patients with RA compared with placebo (normal saline injection) control. However, the number of trials, their quality and the total sample size were too low to draw firm conclusions. PROSPERO 2013: CRD42013005853. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Investigating the sources of variability in the dynamic response of built-up structures through a linear analytical model

    NASA Astrophysics Data System (ADS)

    Abolfathi, Ali; O'Boy, Dan J.; Walsh, Stephen J.; Fisher, Stephen A.

    2017-01-01

    It is well established that the dynamic response of a number of nominally identical built-up structures are often different and the variability increases with increasing complexity of the structure. Furthermore, the effects of the different parameters, for example the variation in joint locations or the range of the Young's modulus, on the dynamic response of the system are not the same. In this paper, the effects of different material and geometric parameters on the variability of a vibration transfer function are compared using an analytical model of a simple linear built-up structure that consist of two plates connected by a single mount. Similar results can be obtained if multiple mounts are used. The scope of this paper is limited to a low and medium frequency range where usually deterministic models are used for vibrational analysis. The effect of the mount position and also the global variation in the properties of the plate, such as modulus of elasticity or thickness, is higher on the variability of vibration transfer function than the effect of the mount properties. It is shown that the vibration transfer function between the plates is independent of the mount property if a stiff enough mount with a small mass is implemented. For a soft mount, there is a direct relationship between the mount impedance and the variation in the vibration transfer function. Furthermore, there are a range of mount stiffnesses between these two extreme cases at which the vibration transfer function is more sensitive to changes in the stiffness of the mount than when compared to a soft mount. It is found that the effect of variation in the mount damping and the mount mass on the variability is negligible. Similarly, the effect of the plate damping on the variability is not significant.

  7. The Shank-to-Vertical-Angle as a parameter to evaluate tuning of Ankle-Foot Orthoses.

    PubMed

    Kerkum, Yvette L; Houdijk, Han; Brehm, Merel-Anne; Buizer, Annemieke I; Kessels, Manon L C; Sterk, Arjan; van den Noort, Josien C; Harlaar, Jaap

    2015-09-01

    The effectiveness of an Ankle-Foot Orthosis footwear combination (AFO-FC) may be partly dependent on the alignment of the ground reaction force with respect to lower limb joint rotation centers, reflected by joint angles and moments. Adjusting (i.e. tuning) the AFO-FC's properties could affect this alignment, which may be guided by monitoring the Shank-to-Vertical-Angle. This study aimed to investigate whether the Shank-to-Vertical-Angle during walking responds to variations in heel height and footplate stiffness, and if this would reflect changes in joint angles and net moments in healthy adults. Ten subjects walked on an instrumented treadmill and performed six trials while walking with bilateral rigid Ankle-Foot Orthoses. The AFO-FC heel height was increased, aiming to impose a Shank-to-Vertical-Angle of 5°, 11° and 20°, and combined with a flexible or stiff footplate. For each trial, the Shank-to-Vertical-Angle, joint flexion-extension angles and net joint moments of the right leg at midstance were averaged over 25 gait cycles. The Shank-to-Vertical-Angle significantly increased with increasing heel height (p<0.001), resulting in an increase in knee flexion angle and internal knee extensor moment (p<0.001). The stiff footplate reduced the effect of heel height on the internal knee extensor moment (p=0.030), while the internal ankle plantar flexion moment increased (p=0.035). Effects of heel height and footplate stiffness on the hip joint were limited. Our results support the potential to use the Shank-to-Vertical-Angle as a parameter to evaluate AFO-FC tuning, as it is responsive to changes in heel height and reflects concomitant changes in the lower limb angles and moments. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Variable stiffness corrugated composite structure with shape memory polymer for morphing skin applications

    NASA Astrophysics Data System (ADS)

    Gong, Xiaobo; Liu, Liwu; Scarpa, Fabrizio; Leng, Jinsong; Liu, Yanju

    2017-03-01

    This work presents a variable stiffness corrugated structure based on a shape memory polymer (SMP) composite with corrugated laminates as reinforcement that shows smooth aerodynamic surface, extreme mechanical anisotropy and variable stiffness for potential morphing skin applications. The smart composite corrugated structure shows a low in-plane stiffness to minimize the actuation energy, but also possess high out-of-plane stiffness to transfer the aerodynamic pressure load. The skin provides an external smooth aerodynamic surface because of the one-sided filling with the SMP. Due to variable stiffness of the shape memory polymer the morphing skin exhibits a variable stiffness with a change of temperature, which can help the skin adjust its stiffness according different service environments and also lock the temporary shape without external force. Analytical models related to the transverse and bending stiffness are derived and validated using finite element techniques. The stiffness of the morphing skin is further investigated by performing a parametric analysis against the geometry of the corrugation and various sets of SMP fillers. The theoretical and numerical models show a good agreement and demonstrate the potential of this morphing skin concept for morphing aircraft applications. We also perform a feasibility study of the use of this morphing skin in a variable camber morphing wing baseline. The results show that the morphing skin concept exhibits sufficient bending stiffness to withstand the aerodynamic load at low speed (less than 0.3 Ma), while demonstrating a large transverse stiffness variation (up to 191 times) that helps to create a maximum mechanical efficiency of the structure under varying external conditions.

  9. An Examination of the True Reliability of Lower Limb Stiffness Measures During Overground Hopping.

    PubMed

    Diggin, David; Anderson, Ross; Harrison, Andrew J

    2016-06-01

    Evidence suggests reports describing the reliability of leg-spring (kleg) and joint stiffness (kjoint) measures are contaminated by artifacts originating from digital filtering procedures. In addition, the intraday reliability of kleg and kjoint requires investigation. This study examined the effects of experimental procedures on the inter- and intraday reliability of kleg and kjoint. Thirty-two participants completed 2 trials of single-legged hopping at 1.5, 2.2, and 3.0 Hz at the same time of day across 3 days. On the final test day a fourth experimental bout took place 6 hours before or after participants' typical testing time. Kinematic and kinetic data were collected throughout. Stiffness was calculated using models of kleg and kjoint. Classifications of measurement agreement were established using thresholds for absolute and relative reliability statistics. Results illustrated that kleg and kankle exhibited strong agreement. In contrast, kknee and khip demonstrated weak-to-moderate consistency. Results suggest limits in kjoint reliability persist despite employment of appropriate filtering procedures. Furthermore, diurnal fluctuations in lower-limb muscle-tendon stiffness exhibit little effect on intraday reliability. The present findings support the existence of kleg as an attractor state during hopping, achieved through fluctuations in kjoint variables. Limits to kjoint reliability appear to represent biological function rather than measurement artifact.

  10. Influence of Passive Joint Stiffness on Proprioceptive Acuity in Individuals With Functional Instability of the Ankle.

    PubMed

    Marinho, Hellen Veloso Rocha; Amaral, Giovanna Mendes; de Souza Moreira, Bruno; Araújo, Vanessa Lara; Souza, Thales Rezende; Ocarino, Juliana Melo; da Fonseca, Sérgio Teixeira

    2017-12-01

    Study Design Controlled laboratory study, cross-sectional. Background Deficits in ankle proprioceptive acuity have been reported in persons with functional instability of the ankle. Passive stiffness has been proposed as a possible mechanism underlying proprioceptive acuity. Objective To compare proprioceptive acuity and passive ankle stiffness in persons with and without functional ankle instability, and to assess the influence of passive joint stiffness on proprioceptive acuity in persons with functional ankle instability. Methods A sample of 18 subjects with and 18 without complaints of functional ankle instability following lateral ankle sprain participated. An isokinetic dynamometer was used to compare motion perception threshold, passive position sense, and passive ankle stiffness between groups. To evaluate the influence of passive stiffness on proprioceptive acuity, individuals in the lateral functional ankle instability group were divided into 2 subgroups: "high" and "low" passive ankle stiffness. Results The functional ankle instability group exhibited increased motion perception threshold when compared with the corresponding limb of the control group. Between-group differences were not found for passive position sense and passive ankle stiffness. Those in the functional ankle instability group with higher passive ankle stiffness had smaller motion perception thresholds than those with lower passive ankle stiffness. Conclusion Unlike motion perception threshold, passive position sense is not affected by the presence of functional ankle instability. Passive ankle stiffness appears to influence proprioceptive acuity in persons with functional ankle instability. J Orthop Sports Phys Ther 2017;47(12):899-905. Epub 7 Oct 2017. doi:10.2519/jospt.2017.7030.

  11. A Study of the Effect of Adhesive and Matrix Stiffnesses on the Axial, Normal, and Shear Stress Distributions of a Boron-epoxy Reinforced Composite Joint. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Howell, W. E.

    1974-01-01

    The mechanical properties of a symmetrical, eight-step, titanium-boron-epoxy joint are discussed. A study of the effect of adhesive and matrix stiffnesses on the axial, normal, and shear stress distributions was made using the finite element method. The NASA Structural Analysis Program (NASTRAN) was used for the analysis. The elastic modulus of the adhesive was varied from 345 MPa to 3100 MPa with the nominal value of 1030 MPa as a standard. The nominal values were used to analyze the stability of the joint. The elastic moduli were varied to determine their effect on the stresses in the joint.

  12. Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

    NASA Astrophysics Data System (ADS)

    Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel

    2018-03-01

    The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

  13. Joint Stability Characteristics of the Ankle Complex in Female Athletes With Histories of Lateral Ankle Sprain, Part II: Clinical Experience Using Arthrometric Measurement

    PubMed Central

    Kovaleski, John E.; Heitman, Robert J.; Gurchiek, Larry R.; Hollis, J. M.; Liu, Wei; IV, Albert W. Pearsall

    2014-01-01

    Context: This is part II of a 2-part series discussing stability characteristics of the ankle complex. In part I, we used a cadaver model to examine the effects of sectioning the lateral ankle ligaments on anterior and inversion motion and stiffness of the ankle complex. In part II, we wanted to build on and apply these findings to the clinical assessment of ankle-complex motion and stiffness in a group of athletes with a history of unilateral ankle sprain. Objective: To examine ankle-complex motion and stiffness in a group of athletes with reported history of lateral ankle sprain. Design: Cross-sectional study. Setting: University research laboratory. Patients or Other Participants: Twenty-five female college athletes (age = 19.4 ± 1.4 years, height = 170.2 ± 7.4 cm, mass = 67.3 ± 10.0 kg) with histories of unilateral ankle sprain. Intervention(s): All ankles underwent loading with an ankle arthrometer. Ankles were tested bilaterally. Main Outcome Measure(s): The dependent variables were anterior displacement, anterior end-range stiffness, inversion rotation, and inversion end-range stiffness. Results: Anterior displacement of the ankle complex did not differ between the uninjured and sprained ankles (P = .37), whereas ankle-complex rotation was greater for the sprained ankles (P = .03). The sprained ankles had less anterior and inversion end-range stiffness than the uninjured ankles (P < .01). Conclusions: Changes in ankle-complex laxity and end-range stiffness were detected in ankles with histories of sprain. These results indicate the presence of altered mechanical characteristics in the soft tissues of the sprained ankles. PMID:24568223

  14. A commercialized dietary supplement alleviates joint pain in community adults: a double-blind, placebo-controlled community trial.

    PubMed

    Nieman, David C; Shanely, R Andrew; Luo, Beibei; Dew, Dustin; Meaney, Mary Pat; Sha, Wei

    2013-11-25

    The purpose of this study was to assess the effect of 8-weeks ingestion of a commercialized joint pain dietary supplement (Instaflex™ Joint Support, Direct Digital, Charlotte, NC) compared to placebo on joint pain, stiffness, and function in adults with self-reported joint pain. Instaflex™ is a joint pain supplement containing glucosamine sulfate, methylsufonlylmethane (MSM), white willow bark extract (15% salicin), ginger root concentrate, boswella serrata extract (65% boswellic acid), turmeric root extract, cayenne, and hyaluronic acid. Subjects included 100 men and women, ages 50-75 years, with a history (>3 months) of joint pain, and were randomized to Instaflex™ or placebo (3 colored gel capsules per day for 8 weeks, double-blind administration). Subjects agreed to avoid the use of non-steroidal anti-inflammatory drugs (NSAID) and all other medications and supplements targeted for joint pain. Primary outcome measures were obtained pre- and post-study and included joint pain severity, stiffness, and function (Western Ontario and McMaster Universities [WOMAC]), and secondary outcome measures included health-related quality of life (Short Form 36 or SF-36), systemic inflammation (serum C-reactive protein and 9 plasma cytokines), and physical function (6-minute walk test). Joint pain symptom severity was assessed bi-weekly using a 12-point Likert visual scale (12-VS). Joint pain severity was significantly reduced in Instaflex™ compared to placebo (8-week WOMAC, ↓37% versus ↓16%, respectively, interaction effect P = 0.025), with group differences using the 12-VS emerging by week 4 of the study (interaction effect, P = 0.0125). Improvements in ability to perform daily activities and stiffness scores in Instaflex™ compared to placebo were most evident for the 74% of subjects reporting knee pain (8-week WOMAC function score, ↓39% versus ↓14%, respectively, interaction effect P = 0.027; stiffness score, ↓30% versus ↓12%, respectively, interaction effect P = 0.081). Patterns of change in SF-36, systemic inflammation biomarkers, and the 6-minute walk test did not differ significantly between groups during the 8-week study Results from this randomized, double blind, placebo-controlled community trial support the use of the Instaflex™ dietary supplement in alleviating joint pain severity in middle-aged and older adults, with mitigation of difficulty performing daily activities most apparent in subjects with knee pain.

  15. Improved Function and Reduced Pain after Swimming and Cycling Training in Patients with Osteoarthritis.

    PubMed

    Alkatan, Mohammed; Baker, Jeffrey R; Machin, Daniel R; Park, Wonil; Akkari, Amanda S; Pasha, Evan P; Tanaka, Hirofumi

    2016-03-01

    Arthritis and its associated joint pain act as significant barriers for adults attempting to perform land-based physical activity. Swimming can be an ideal form of exercise for patients with arthritis. Yet there is no information on the efficacy of regular swimming exercise involving patients with arthritis. The effect of a swimming exercise intervention on joint pain, stiffness, and physical function was evaluated in patients with osteoarthritis (OA). Using a randomized study design, 48 sedentary middle-aged and older adults with OA underwent 3 months of either swimming or cycling exercise training. Supervised exercise training was performed for 45 min/day, 3 days/week at 60-70% heart rate reserve for 12 weeks. The Western Ontario and McMaster Universities Arthritis Index was used to measure joint pain, stiffness, and physical limitation. After the exercise interventions, there were significant reductions in joint pain, stiffness, and physical limitation accompanied by increases in quality of life in both groups (all p < 0.05). Functional capacity as assessed by maximal handgrip strength, isokinetic knee extension and flexion power (15-30% increases), and the distance covered in the 6-min walk test increased (all p < 0.05) in both exercise groups. No differences were observed in the magnitude of improvements between swimming and cycling training. Regular swimming exercise reduced joint pain and stiffness associated with OA and improved muscle strength and functional capacity in middle-aged and older adults with OA. Additionally, the benefits of swimming exercise were similar to the more frequently prescribed land-based cycling training. clinicaltrials.gov NCT01836380.

  16. Development of a mechatronic platform and validation of methods for estimating ankle stiffness during the stance phase of walking.

    PubMed

    Rouse, Elliott J; Hargrove, Levi J; Perreault, Eric J; Peshkin, Michael A; Kuiken, Todd A

    2013-08-01

    The mechanical properties of human joints (i.e., impedance) are constantly modulated to precisely govern human interaction with the environment. The estimation of these properties requires the displacement of the joint from its intended motion and a subsequent analysis to determine the relationship between the imposed perturbation and the resultant joint torque. There has been much investigation into the estimation of upper-extremity joint impedance during dynamic activities, yet the estimation of ankle impedance during walking has remained a challenge. This estimation is important for understanding how the mechanical properties of the human ankle are modulated during locomotion, and how those properties can be replicated in artificial prostheses designed to restore natural movement control. Here, we introduce a mechatronic platform designed to address the challenge of estimating the stiffness component of ankle impedance during walking, where stiffness denotes the static component of impedance. The system consists of a single degree of freedom mechatronic platform that is capable of perturbing the ankle during the stance phase of walking and measuring the response torque. Additionally, we estimate the platform's intrinsic inertial impedance using parallel linear filters and present a set of methods for estimating the impedance of the ankle from walking data. The methods were validated by comparing the experimentally determined estimates for the stiffness of a prosthetic foot to those measured from an independent testing machine. The parallel filters accurately estimated the mechatronic platform's inertial impedance, accounting for 96% of the variance, when averaged across channels and trials. Furthermore, our measurement system was found to yield reliable estimates of stiffness, which had an average error of only 5.4% (standard deviation: 0.7%) when measured at three time points within the stance phase of locomotion, and compared to the independently determined stiffness values of the prosthetic foot. The mechatronic system and methods proposed in this study are capable of accurately estimating ankle stiffness during the foot-flat region of stance phase. Future work will focus on the implementation of this validated system in estimating human ankle impedance during the stance phase of walking.

  17. Experimental characterization and numerical simulation of riveted lap-shear joints using Rivet Element

    NASA Astrophysics Data System (ADS)

    Vivio, Francesco; Fanelli, Pierluigi; Ferracci, Michele

    2018-03-01

    In aeronautical and automotive industries the use of rivets for applications requiring several joining points is now very common. In spite of a very simple shape, a riveted junction has many contact surfaces and stress concentrations that make the local stiffness very difficult to be calculated. To overcome this difficulty, commonly finite element models with very dense meshes are performed for single joint analysis because the accuracy is crucial for a correct structural analysis. Anyhow, when several riveted joints are present, the simulation becomes computationally too heavy and usually significant restrictions to joint modelling are introduced, sacrificing the accuracy of local stiffness evaluation. In this paper, we tested the accuracy of a rivet finite element presented in previous works by the authors. The structural behaviour of a lap joint specimen with a rivet joining is simulated numerically and compared to experimental measurements. The Rivet Element, based on a closed-form solution of a reference theoretical model of the rivet joint, simulates local and overall stiffness of the junction combining high accuracy with low degrees of freedom contribution. In this paper the Rivet Element performances are compared to that of a FE non-linear model of the rivet, built with solid elements and dense mesh, and to experimental data. The promising results reported allow to consider the Rivet Element able to simulate, with a great accuracy, actual structures with several rivet connections.

  18. Dwarfism

    MedlinePlus

    ... dwarfism might have: cleft palate hand and ear differences hip dysplasia club feet severe curvature of the spine early deterioration of joints and joint stiffness potential hip and knee dislocation Complications From Spondyloepiphyseal Dysplasia ...

  19. Adaptation of multijoint coordination during standing balance in healthy young and healthy old individuals

    PubMed Central

    Pasma, J. H.; Schouten, A. C.; Aarts, R. G. K. M.; Meskers, C. G. M.; Maier, A. B.; van der Kooij, H.

    2015-01-01

    Standing balance requires multijoint coordination between the ankles and hips. We investigated how humans adapt their multijoint coordination to adjust to various conditions and whether the adaptation differed between healthy young participants and healthy elderly. Balance was disturbed by push/pull rods, applying two continuous and independent force disturbances at the level of the hip and between the shoulder blades. In addition, external force fields were applied, represented by an external stiffness at the hip, either stabilizing or destabilizing the participants' balance. Multivariate closed-loop system-identification techniques were used to describe the neuromuscular control mechanisms by quantifying the corrective joint torques as a response to body sway, represented by frequency response functions (FRFs). Model fits on the FRFs resulted in an estimation of time delays, intrinsic stiffness, reflexive stiffness, and reflexive damping of both the ankle and hip joint. The elderly generated similar corrective joint torques but had reduced body sway compared with the young participants, corresponding to the increased FRF magnitude with age. When a stabilizing or destabilizing external force field was applied at the hip, both young and elderly participants adapted their multijoint coordination by lowering or respectively increasing their neuromuscular control actions around the ankles, expressed in a change of FRF magnitude. However, the elderly adapted less compared with the young participants. Model fits on the FRFs showed that elderly had higher intrinsic and reflexive stiffness of the ankle, together with higher time delays of the hip. Furthermore, the elderly adapted their reflexive stiffness around the ankle joint less compared with young participants. These results imply that elderly were stiffer and were less able to adapt to external force fields. PMID:26719084

  20. Functional Capacity in Adults With Cerebral Palsy: Lower Limb Muscle Strength Matters.

    PubMed

    Gillett, Jarred G; Lichtwark, Glen A; Boyd, Roslyn N; Barber, Lee A

    2018-05-01

    To investigate the relation between lower limb muscle strength, passive muscle properties, and functional capacity outcomes in adults with cerebral palsy (CP). Cross-sectional study. Tertiary institution biomechanics laboratory. Adults with spastic-type CP (N=33; mean age, 25y; range, 15-51y; mean body mass, 70.15±21.35kg) who were either Gross Motor Function Classification System (GMFCS) level I (n=20) or level II (n=13). Not applicable. Six-minute walk test (6MWT) distance (m), lateral step-up (LSU) test performance (total repetitions), timed up-stairs (TUS) performance (s), maximum voluntary isometric strength of plantar flexors (PF) and dorsiflexors (DF) (Nm.kg -1 ), and passive ankle joint and muscle stiffness. Maximum isometric PF strength independently explained 61% of variance in 6MWT performance, 57% of variance in LSU test performance, and 50% of variance in TUS test performance. GMFCS level was significantly and independently related to all 3 functional capacity outcomes, and age was retained as a significant independent predictor of LSU and TUS test performance. Passive medial gastrocnemius muscle fascicle stiffness and ankle joint stiffness were not significantly related to functional capacity measures in any of the multiple regression models. Low isometric PF strength was the most important independent variable related to distance walked on the 6MWT, fewer repetitions on the LSU test, and slower TUS test performance. These findings suggest lower isometric muscle strength contributes to the decline in functional capacity in adults with CP. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Altered astronaut lower limb and mass center kinematics in downward jumping following space flight

    NASA Technical Reports Server (NTRS)

    Newman, D. J.; Jackson, D. K.; Bloomberg, J. J.

    1997-01-01

    Astronauts exposed to the microgravity conditions encountered during space flight exhibit postural and gait instabilities upon return to earth that could impair critical postflight performance. The aim of the present study was to determine the effects of microgravity exposure on astronauts' performance of two-footed jump landings. Nine astronauts from several Space Shuttle missions were tested both preflight and postflight with a series of voluntary, two-footed downward hops from a 30-cm-high step. A video-based, three-dimensional motion-analysis system permitted calculation of body segment positions and joint angular displacements. Phase-plane plots of knee, hip, and ankle angular velocities compared with the corresponding joint angles were used to describe the lower limb kinematics during jump landings. The position of the whole-body center of mass (COM) was also estimated in the sagittal plane using an eight-segment body model. Four of nine subjects exhibited expanded phase-plane portraits postflight, with significant increases in peak joint flexion angles and flexion rates following space flight. In contrast, two subjects showed significant contractions of their phase-plane portraits postflight and three subjects showed insignificant overall changes after space flight. Analysis of the vertical COM motion generally supported the joint angle results. Subjects with expanded joint angle phase-plane portraits postflight exhibited larger downward deviations of the COM and longer times from impact to peak deflection, as well as lower upward recovery velocities. Subjects with postflight joint angle phase-plane contraction demonstrated opposite effects in the COM motion. The joint kinematics results indicated the existence of two contrasting response modes due to microgravity exposure. Most subjects exhibited "compliant" impact absorption postflight, consistent with decreased limb stiffness and damping, and a reduction in the bandwidth of the postural control system. Fewer subjects showed "stiff" behavior after space flight, where contractions in the phase-plane portraits pointed to an increase in control bandwidth. The changes appeared to result from adaptive modifications in the control of lower limb impedance. A simple 2nd-order model of the vertical COM motion indicated that changes in the effective vertical stiffness of the legs can predict key features of the postflight performance. Compliant responses may reflect inflight adaptation due to altered demands on the postural control system in microgravity, while stiff behavior may result from overcompensation postflight for the presumed reduction in limb stiffness inflight.

  2. New insights on equid locomotor evolution from the lumbar region of fossil horses

    PubMed Central

    Jones, Katrina Elizabeth

    2016-01-01

    The specialization of equid limbs for cursoriality is a classic case of adaptive evolution, but the role of the axial skeleton in this famous transition is not well understood. Extant horses are extremely fast and efficient runners, which use a stiff-backed gallop with reduced bending of the lumbar region relative to other mammals. This study tests the hypothesis that stiff-backed running in horses evolved in response to evolutionary increases in body size by examining lumbar joint shape from a broad sample of fossil equids in a phylogenetic context. Lumbar joint shape scaling suggests that stability of the lumbar region does correlate with size through equid evolution. However, scaling effects were dampened in the posterior lumbar region, near the sacrum, which suggests strong selection for sagittal mobility in association with locomotor–respiratory coupling near the lumbosacral joint. I hypothesize that small-bodied fossil horses may have used a speed-dependent running gait, switching between stiff-backed and flex-backed galloping as speed increased. PMID:27122554

  3. Manipulation under Anesthesia for Stiffness after Total Knee Arthroplasty

    PubMed Central

    Yoo, Ju-Hyung; Oh, Jin-Cheol; Park, Sang-Hoon

    2015-01-01

    Purpose This study evaluated the incidence of manipulation under anesthesia (MUA) for stiffness after total knee arthroplasty (TKA) and the degree of joint motion recovery after MUA. Materials and Methods A total of 4,449 TKAs (2,973 patients) were performed between March 2000 and August 2014. Cases that underwent MUA for stiffness after TKA were reviewed. TKAs were performed using the conventional procedure in 329 cases and using the minimally invasive procedure in 4,120 cases. The preoperative range of joint motion, timing of manipulation, diagnosis and the range of joint motion before and after MUA were retrospectively investigated. Results MUA was carried out in 22 cases (16 patients), resulting in the incidence of 0.5%. The incidence after the conventional procedure was 1.2% and 0.4% after the minimally invasive procedure. In the manipulated knees, the preoperative range of motion (ROM) was 102.5°±26.7°, and the preoperative diagnosis was osteoarthritis in 19 cases, rheumatoid arthritis in two, and infection sequela in one. MUA was performed 4.7±3.0 weeks after TKA. The average ROM was 64.5°±13.5° before manipulation. At an average of 64.3±41.3 months after manipulation, the ROM was recovered to 113.4°±31.2°, which was an additional 49.9° improvement in flexion. Conclusions The satisfactory recovery of joint movement was achieved when MUA for stiffness was performed relatively early after TKA. PMID:26676186

  4. Quasi-stiffness of the knee joint in flexion and extension during the golf swing.

    PubMed

    Choi, Ahnryul; Sim, Taeyong; Mun, Joung Hwan

    2015-01-01

    Biomechanical understanding of the knee joint during a golf swing is essential to improve performance and prevent injury. In this study, we quantified the flexion/extension angle and moment as the primary knee movement, and evaluated quasi-stiffness represented by moment-angle coupling in the knee joint. Eighteen skilled and 23 unskilled golfers participated in this study. Six infrared cameras and two force platforms were used to record a swing motion. The anatomical angle and moment were calculated from kinematic and kinetic models, and quasi-stiffness of the knee joint was determined as an instantaneous slope of moment-angle curves. The lead knee of the skilled group had decreased resistance duration compared with the unskilled group (P < 0.05), and the resistance duration of the lead knee was lower than that of the trail knee in the skilled group (P < 0.01). The lead knee of the skilled golfers had greater flexible excursion duration than the trail knee of the skilled golfers, and of both the lead and trail knees of the unskilled golfers. These results provide critical information for preventing knee injuries during a golf swing and developing rehabilitation strategies following surgery.

  5. An Extended Passive Motion Paradigm for Human-Like Posture and Movement Planning in Redundant Manipulators

    PubMed Central

    Tommasino, Paolo; Campolo, Domenico

    2017-01-01

    A major challenge in robotics and computational neuroscience is relative to the posture/movement problem in presence of kinematic redundancy. We recently addressed this issue using a principled approach which, in conjunction with nonlinear inverse optimization, allowed capturing postural strategies such as Donders' law. In this work, after presenting this general model specifying it as an extension of the Passive Motion Paradigm, we show how, once fitted to capture experimental postural strategies, the model is actually able to also predict movements. More specifically, the passive motion paradigm embeds two main intrinsic components: joint damping and joint stiffness. In previous work we showed that joint stiffness is responsible for static postures and, in this sense, its parameters are regressed to fit to experimental postural strategies. Here, we show how joint damping, in particular its anisotropy, directly affects task-space movements. Rather than using damping parameters to fit a posteriori task-space motions, we make the a priori hypothesis that damping is proportional to stiffness. This remarkably allows a postural-fitted model to also capture dynamic performance such as curvature and hysteresis of task-space trajectories during wrist pointing tasks, confirming and extending previous findings in literature. PMID:29249954

  6. Forms of Arthritis

    MedlinePlus

    ... stiffness, inflammation, swelling and, sometimes, destruction of joints. Gout — a form of arthritis that occurs when uric ... the joints. Some 2.1 million Americans have gout. Lupus — a form of arthritis, like rheumatoid arthritis, ...

  7. Analysis of kinematically redundant reaching movements using the equilibrium-point hypothesis.

    PubMed

    Cesari, P; Shiratori, T; Olivato, P; Duarte, M

    2001-03-01

    Six subjects performed a planar reaching arm movement to a target while unpredictable perturbations were applied to the endpoint; the perturbations consisted of pulling springs having different stiffness. Two conditions were applied; in the first, subjects had to reach for the target despite the perturbation, in the second condition, the subjects were asked to not correct the motion as a perturbation was applied. We analyzed the kinematics profiles of the three arm segments and, by means of inverse dynamics, calculated the joint torques. The framework of the equilibrium-point (EP) hypothesis, the lambda model, allowed the reconstruction of the control variables, the "equilibrium trajectories", in the "do not correct" condition for the wrist and the elbow joints as well as for the end point final position, while for the other condition, the reconstruction was less reliable. The findings support and extend to a multiple-joint planar movement, the paradigm of the EP hypothesis along with the "do not correct" instruction.

  8. Stiff, Strong Splice For A Composite Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Schmaling, D.

    1991-01-01

    New type of splice for composite sandwich structure reduces peak shear stress in structure. Layers of alternating fiber orientation interposed between thin ears in adhesive joint. Developed for structural joint in spar of helicopter rotor blade, increases precision of control over thickness of adhesive at joint. Joint easy to make, requires no additional pieces, and adds little weight.

  9. A commercialized dietary supplement alleviates joint pain in community adults: a double-blind, placebo-controlled community trial

    PubMed Central

    2013-01-01

    Background The purpose of this study was to assess the effect of 8-weeks ingestion of a commercialized joint pain dietary supplement (InstaflexTM Joint Support, Direct Digital, Charlotte, NC) compared to placebo on joint pain, stiffness, and function in adults with self-reported joint pain. InstaflexTM is a joint pain supplement containing glucosamine sulfate, methylsufonlylmethane (MSM), white willow bark extract (15% salicin), ginger root concentrate, boswella serrata extract (65% boswellic acid), turmeric root extract, cayenne, and hyaluronic acid. Methods Subjects included 100 men and women, ages 50-75 years, with a history (>3 months) of joint pain, and were randomized to Instaflex™ or placebo (3 colored gel capsules per day for 8 weeks, double-blind administration). Subjects agreed to avoid the use of non-steroidal anti-inflammatory drugs (NSAID) and all other medications and supplements targeted for joint pain. Primary outcome measures were obtained pre- and post-study and included joint pain severity, stiffness, and function (Western Ontario and McMaster Universities [WOMAC]), and secondary outcome measures included health-related quality of life (Short Form 36 or SF-36), systemic inflammation (serum C-reactive protein and 9 plasma cytokines), and physical function (6-minute walk test). Joint pain symptom severity was assessed bi-weekly using a 12-point Likert visual scale (12-VS). Results Joint pain severity was significantly reduced in Instaflex™ compared to placebo (8-week WOMAC, ↓37% versus ↓16%, respectively, interaction effect P = 0.025), with group differences using the 12-VS emerging by week 4 of the study (interaction effect, P = 0.0125). Improvements in ability to perform daily activities and stiffness scores in Instaflex™ compared to placebo were most evident for the 74% of subjects reporting knee pain (8-week WOMAC function score, ↓39% versus ↓14%, respectively, interaction effect P = 0.027; stiffness score, ↓30% versus ↓12%, respectively, interaction effect P = 0.081). Patterns of change in SF-36, systemic inflammation biomarkers, and the 6-minute walk test did not differ significantly between groups during the 8-week study Conclusions Results from this randomized, double blind, placebo-controlled community trial support the use of the Instaflex™ dietary supplement in alleviating joint pain severity in middle-aged and older adults, with mitigation of difficulty performing daily activities most apparent in subjects with knee pain. Trial registration ClinicalTrials.gov Identifier: NCT01956500 PMID:24274358

  10. An acoustic startle alters knee joint stiffness and neuromuscular control.

    PubMed

    DeAngelis, A I; Needle, A R; Kaminski, T W; Royer, T R; Knight, C A; Swanik, C B

    2015-08-01

    Growing evidence suggests that the nervous system contributes to non-contact knee ligament injury, but limited evidence has measured the effect of extrinsic events on joint stability. Following unanticipated events, the startle reflex leads to universal stiffening of the limbs, but no studies have investigated how an acoustic startle influences knee stiffness and muscle activation during a dynamic knee perturbation. Thirty-six individuals were tested for knee stiffness and muscle activation of the quadriceps and hamstrings. Subjects were seated and instructed to resist a 40-degree knee flexion perturbation from a relaxed state. During some trials, an acoustic startle (50 ms, 1000 Hz, 100 dB) was applied 100 ms prior to the perturbation. Knee stiffness, muscle amplitude, and timing were quantified across time, muscle, and startle conditions. The acoustic startle increased short-range (no startle: 0.044 ± 0.011 N·m/deg/kg; average startle: 0.047 ± 0.01 N·m/deg/kg) and total knee stiffness (no startle: 0.036 ± 0.01 N·m/deg/kg; first startle 0.027 ± 0.02 N·m/deg/kg). Additionally, the startle contributed to decreased [vastus medialis (VM): 13.76 ± 33.6%; vastus lateralis (VL): 6.72 ± 37.4%] but earlier (VM: 0.133 ± 0.17 s; VL: 0.124 ± 0.17 s) activation of the quadriceps muscles. The results of this study indicate that the startle response can significantly disrupt knee stiffness regulation required to maintain joint stability. Further studies should explore the role of unanticipated events on unintentional injury. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. The Relationship Between Early-Stage Knee Osteoarthritis and Lower-Extremity Alignment, Joint Laxity, and Subjective Scores of Pain, Stiffness, and Function.

    PubMed

    Hicks-Little, Charlie A; Peindl, Richard D; Hubbard-Turner, Tricia J; Cordova, Mitchell L

    2016-08-01

    Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. Case control. Sports-medicine research laboratory. 18 participants with knee OA and 18 healthy matched controls. Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). WOMAC scores, A-P (mm), and ALIGN (°). A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P < .0001) was found. Knee-OA participants differed in WOMAC scores (P < .0001) but did not differ from healthy controls on ALIGN (P = .49) or total A-P (P = .66). No significant relationships were identified among main outcome measures. These data demonstrate that participants with early-stage knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.

  12. Effects of hamstring stretching on passive muscle stiffness vary between hip flexion and knee extension maneuvers.

    PubMed

    Miyamoto, N; Hirata, K; Kanehisa, H

    2017-01-01

    The purpose of this study was to examine whether the effects of hamstring stretching on the passive stiffness of each of the long head of the biceps femoris (BFl), semitendinosus (ST), and semimembranosus (SM) vary between passive knee extension and hip flexion stretching maneuvers. In 12 male subjects, before and after five sets of 90 s static stretching, passive lengthening measurements where knee or hip joint was passively rotated to the maximal range of motion (ROM) were performed. During the passive lengthening, shear modulus of each muscle was measured by ultrasound shear wave elastography. Both stretching maneuvers significantly increased maximal ROM and decreased passive torque at a given joint angle. Passive knee extension stretching maneuver significantly reduced shear modulus at a given knee joint angle in all of BFl, ST, and SM. In contrast, the stretching effect by passive hip flexion maneuver was significant only in ST and SM. The present findings indicate that the effects of hamstring stretching on individual passive muscles' stiffness vary between passive knee extension and hip flexion stretching maneuvers. In terms of reducing the muscle stiffness of BFl, stretching of the hamstring should be performed by passive knee extension rather than hip flexion. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Is statin use associated with new joint-related symptoms, physical function, and quality of life? Results from two population-based cohorts of women.

    PubMed

    Peeters, Geeske; Tett, Susan E; Conaghan, Philip G; Mishra, Gita D; Dobson, Annette J

    2015-01-01

    Previous studies have suggested that statins may prevent development of osteoarthritis and have antiinflammatory effects. Our aim was to examine the associations between statin use and patient-reported joint symptoms in 2 large cohorts of middle-aged and older women. Data were from 6,966 middle-aged (born 1946-1951) and 4,806 older (born 1921-1926) participants in the Australian Longitudinal Study on Women's Health who completed surveys from 2001 to 2011, including questions about joint pain/stiffness, physical functioning, and self-rated health (SRH). Administrative pharmaceutical data were used to classify participants according to statin use, cumulative volume of statin use, and type of drug. Associations between statin use and newly reported symptoms were analyzed using logistic regression with generalized estimating equations to account for repeated measures. A total of 2,096 (31.3%) of the middle-aged women and 2,473 (51.5%) of the older women were classified as statin users. After adjustment for confounders, statin use in middle-aged women was weakly associated with poor physical functioning (odds ratio [OR] 1.29, 99% confidence interval [99% CI] 1.07-1.55) and poor SRH (OR 1.35, 99% CI 1.13-1.61), but not with new joint pain/stiffness (OR 1.09, 99% CI 0.88-1.34). No dose-response relationships were found. Pravastatin and atorvastatin were associated with poor physical functioning, while atorvastatin was also associated with poor SRH. Associations found in older women were mostly explained by confounders. This large study did not demonstrate an association between statin use and reduced onset of joint pain/stiffness. Associations between statin use and poor physical functioning and poor SRH may be explained by factors other than joint pain/stiffness, e.g., muscle pain. Copyright © 2015 by the American College of Rheumatology.

  14. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite

    PubMed Central

    He, Minjuan; Tao, Duo; Li, Zheng; Li, Maolin

    2016-01-01

    As a renewable building material with low embodied energy characteristics, wood has gained more and more attention in the green and sustainable building industry. In terms of material resource and physical properties, scrimber composite not only makes full use of fast-growing wood species, but also has better mechanical performance and less inherent variability than natural wood material. In this study, the mechanical behavior of bolted beam-to-column joints built with a kind of scrimber composite was investigated both experimentally and numerically. Two groups of specimens were tested under monotonic and low frequency cyclic loading protocols. The experimental results showed that the bolted joints built with scrimber composite performed well in initial stiffness, ductility, and energy dissipation. A three-dimensional (3D) non-linear finite element model (FEM) for the bolted beam-to-column joints was then developed and validated by experimental results. The validated model was further used to investigate the failure mechanism of the bolted joints through stress analysis. This study can contribute to the application of the proposed scrimber composite in structural engineering, and the developed FEM can serve as a useful tool to evaluate the mechanical behavior of such bolted beam-to-column joints with different configurations in future research. PMID:28773703

  15. Mechanical Behavior of Dowel-Type Joints Made of Wood Scrimber Composite.

    PubMed

    He, Minjuan; Tao, Duo; Li, Zheng; Li, Maolin

    2016-07-15

    As a renewable building material with low embodied energy characteristics, wood has gained more and more attention in the green and sustainable building industry. In terms of material resource and physical properties, scrimber composite not only makes full use of fast-growing wood species, but also has better mechanical performance and less inherent variability than natural wood material. In this study, the mechanical behavior of bolted beam-to-column joints built with a kind of scrimber composite was investigated both experimentally and numerically. Two groups of specimens were tested under monotonic and low frequency cyclic loading protocols. The experimental results showed that the bolted joints built with scrimber composite performed well in initial stiffness, ductility, and energy dissipation. A three-dimensional (3D) non-linear finite element model (FEM) for the bolted beam-to-column joints was then developed and validated by experimental results. The validated model was further used to investigate the failure mechanism of the bolted joints through stress analysis. This study can contribute to the application of the proposed scrimber composite in structural engineering, and the developed FEM can serve as a useful tool to evaluate the mechanical behavior of such bolted beam-to-column joints with different configurations in future research.

  16. Mechanisms of Shoulder Range of Motion Deficits in Asymptomatic Baseball Players.

    PubMed

    Bailey, Lane B; Shanley, Ellen; Hawkins, Richard; Beattie, Paul F; Fritz, Stacy; Kwartowitz, David; Thigpen, Charles A

    2015-11-01

    Shoulder range of motion (ROM) deficits have been identified as injury risk factors among baseball athletes. Despite the knowledge surrounding these risk factors, there is a lack of consensus regarding the specific tissues responsible for these deficits in ROM. The purpose of this study was to elucidate the primary mechanisms of posterior shoulder tightness (capsular, musculotendinous, bony) by examining the tissue responses that occur with the application of an acute intervention in baseball players with ROM deficits. The hypothesis was that posterior rotator cuff stiffness, not glenohumeral joint mobility, would be primarily responsible for ROM gains observed within an acute treatment setting. Controlled laboratory study. Through use of ultrasound elastography, electromagnetic motion analysis, and ultrasound imaging, posterior rotator cuff stiffness, glenohumeral joint translation, and humeral torsion were examined in 60 asymptomatic baseball players (age, mean ± SD, 19 ± 2 years) with shoulder ROM deficits. Tissue mechanisms were examined concurrently, with the ROM gains elicited by an acute application of instrument-assisted soft tissue mobilization plus self-stretching (n = 30) versus self-stretching only (n = 30). Separate 3-way analyses of variance (group × arm × time) and linear regression analyses were used to determine the treatment effects and relationships between tissue mechanisms and ROM gains. ROM gains were associated with decreases in rotator cuff stiffness (internal rotation: r = 0.35, P = .034; horizontal adduction: r = 0.44, P = .008) and increased humeral retrotorsion (internal rotation: r = -0.35, P = .034), not joint translation (P > .05). Players receiving instrument-assisted soft tissue mobilization plus stretching displayed greater shoulder ROM gains (internal rotation, +5° ± 2° [P = .010]; total arc of motion, +8° ± 6° [P = .010]; horizontal adduction, +7° ± 2° [P = .004]; and decreased posterior rotator cuff stiffness, -0.2 ± 0.3 kPa [P = .050]) compared with players receiving self-stretching alone. Decreases in rotator cuff stiffness were associated with acute ROM gains in baseball players. The study results show that changes in rotator cuff stiffness, not glenohumeral joint mobility or humeral torsion, are most likely associated with the ROM deficits observed in adolescent baseball players. Reducing rotator cuff stiffness may be beneficial in improving the ROM deficits associated with injury risk in overhead athletes. © 2015 The Author(s).

  17. Velocity-based planning of rapid elbow movements expands the control scheme of the equilibrium point hypothesis.

    PubMed

    Suzuki, Masataka; Yamazaki, Yoshihiko

    2005-01-01

    According to the equilibrium point hypothesis of voluntary motor control, control action of muscles is not explicitly computed, but rather arises as a consequence of interaction between moving equilibrium position, current kinematics and stiffness of the joint. This approach is attractive as it obviates the need to explicitly specify the forces controlling limb movements. However, many debatable aspects of this hypothesis remain in the manner of specification of the equilibrium point trajectory and muscle activation (or its stiffness), which elicits a restoring force toward the planned equilibrium trajectory. In this study, we expanded the framework of this hypothesis by assuming that the control system uses the velocity measure as the origin of subordinate variables scaling descending commands. The velocity command is translated into muscle control inputs by second order pattern generators, which yield reciprocal command and coactivation commands, and create alternating activation of the antagonistic muscles during movement and coactivation in the post-movement phase, respectively. The velocity command is also integrated to give a position command specifying a moving equilibrium point. This model is purely kinematics-dependent, since the descending commands needed to modulate the visco-elasticity of muscles are implicitly given by simple parametric specifications of the velocity command alone. The simulated movements of fast elbow single-joint movements corresponded well with measured data performed over a wide range of movement distances, in terms of both muscle excitations and kinematics. Our proposal on a synthesis for the equilibrium point approach and velocity command, may offer some insights into the control scheme of the single-joint arm movements.

  18. X-ray motion analysis of the vertebral column during the startle response in striped bass, Morone saxatilis.

    PubMed

    Nowroozi, B N; Brainerd, E L

    2013-08-01

    Whole-body stiffness has a substantial impact on propulsive wave speed during axial undulatory locomotion in fishes. The connective tissues of the vertebral column may contribute to body stiffness, but without mechanical and kinematic analysis it is unclear whether the in vivo range of motion of intervertebral joints (IVJs) is great enough to stress IVJ tissues, thus generating stiffness. The present study used 2D videoradiography and 3D X-ray reconstruction of moving morphology (XROMM) to quantify vertebral kinematics during the startle response in striped bass (Morone saxatilis). X-ray video revealed two distinct patterns of bending: pattern I begins in the abdominal region and then proceeds to maximum IVJ angles in the caudal region, whereas pattern II begins in the cervical region and proceeds to maximum IVJ angles in the abdominal and then the caudal joints. In pattern II bends, the cervical joints exhibit a greater in vivo range of motion than previously reported in other species. XROMM analysis of caudal IVJs suggests primarily lateral bending: mean axial and dorsoventral rotations were less than 2 deg and inconsistent across 51 sequences analyzed from five individuals, whereas mean maximum lateral bending angles were 10.4±3.57 deg. These angles, combined with previous investigations of mechanical properties, reveal that the maximum angles all occur within the neutral zone of bending, indicating that little stress is experienced about the joint. This suggests that the IVJs of striped bass are quite compliant and likely do not contribute significantly to whole-body stiffness or elastic recoil during swimming in vivo.

  19. Control of paraplegic ankle joint stiffness using FES while standing.

    PubMed

    Hunt, K J; Gollee, H; Jaime, R P

    2001-10-01

    The goal of this work was to investigate the feasibility of ankle stiffness control using functional electrical stimulation (FES) while standing, as relevant to the development of feedback systems for balance control in paraplegia. The work was carried out using apparatus in which the subject stands with all joints above the ankles braced, and where ankle moment is provided via FES of the ankle flexor and extensor muscles. A feedback control strategy for ankle stiffness control is proposed in which the ankle moment is controlled to a reference value equal to the product of the desired stiffness and the measured ankle angle. Two subjects participated in the study: one neurologically-intact person, and one paraplegic person with a complete thoracic spinal cord lesion. The results show that during forward-leaning postures, when the plantarflexor muscles are stimulated, relatively high ankle moments of up to 60 Nm can be generated and accurate moment tracking is achieved. As a consequence, ankle stiffness is close to the desired value. During backward lean, on the other hand, the dorsiflexor muscles are stimulated. These muscles are relatively weak and only modest ankle moments of up to around 15 Nm can be produced. As a result, dorsiflexor stimulation readily saturates giving poor stiffness control. It was further observed that when the desired stiffness is higher more external force has to be applied to perturb the body away from the neutral (upright) position. We conclude that: (i) accurate ankle stiffness control, up to the fundamental strength limits of the muscles, can be achieved with controlled FES; (ii) ankle stiffness control using FES in paraplegia has the potential to ease the task of stabilising upright posture by application of additional upper-body forces.

  20. The effects of prosthetic foot stiffness on transtibial amputee walking mechanics and balance control during turning.

    PubMed

    Shell, Courtney E; Segal, Ava D; Klute, Glenn K; Neptune, Richard R

    2017-11-01

    Little evidence exists regarding how prosthesis design characteristics affect performance in tasks that challenge mediolateral balance such as turning. This study assesses the influence of prosthetic foot stiffness on amputee walking mechanics and balance control during a continuous turning task. Three-dimensional kinematic and kinetic data were collected from eight unilateral transtibial amputees as they walked overground at self-selected speed clockwise and counterclockwise around a 1-meter circle and along a straight line. Subjects performed the walking tasks wearing three different ankle-foot prostheses that spanned a range of sagittal- and coronal-plane stiffness levels. A decrease in stiffness increased residual ankle dorsiflexion (10-13°), caused smaller adaptations (<5°) in proximal joint angles, decreased residual and increased intact limb body support, increased residual limb propulsion and increased intact limb braking for all tasks. While changes in sagittal-plane joint work due to decreased stiffness were generally consistent across tasks, effects on coronal-plane hip work were task-dependent. When the residual limb was on the inside of the turn and during straight-line walking, coronal-plane hip work increased and coronal-plane peak-to-peak range of whole-body angular momentum decreased with decreased stiffness. Changes in sagittal-plane kinematics and kinetics were similar to those previously observed in straight-line walking. Mediolateral balance improved with decreased stiffness, but adaptations in coronal-plane angles, work and ground reaction force impulses were less systematic than those in sagittal-plane measures. Effects of stiffness varied with the residual limb inside versus outside the turn, which suggests that actively adjusting stiffness to turn direction may be beneficial. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Dynamically variable negative stiffness structures.

    PubMed

    Churchill, Christopher B; Shahan, David W; Smith, Sloan P; Keefe, Andrew C; McKnight, Geoffrey P

    2016-02-01

    Variable stiffness structures that enable a wide range of efficient load-bearing and dexterous activity are ubiquitous in mammalian musculoskeletal systems but are rare in engineered systems because of their complexity, power, and cost. We present a new negative stiffness-based load-bearing structure with dynamically tunable stiffness. Negative stiffness, traditionally used to achieve novel response from passive structures, is a powerful tool to achieve dynamic stiffness changes when configured with an active component. Using relatively simple hardware and low-power, low-frequency actuation, we show an assembly capable of fast (<10 ms) and useful (>100×) dynamic stiffness control. This approach mitigates limitations of conventional tunable stiffness structures that exhibit either small (<30%) stiffness change, high friction, poor load/torque transmission at low stiffness, or high power active control at the frequencies of interest. We experimentally demonstrate actively tunable vibration isolation and stiffness tuning independent of supported loads, enhancing applications such as humanoid robotic limbs and lightweight adaptive vibration isolators.

  2. Juvenile Arthritis

    MedlinePlus

    Juvenile arthritis (JA) is arthritis that happens in children. It causes joint swelling, pain, stiffness, and loss of motion. It can affect any joint, but ... of JA that children get is juvenile idiopathic arthritis. There are several other forms of arthritis affecting ...

  3. Evaluation of Silicone as an Artificial Lubricant in Osteoarthrotic Joints

    PubMed Central

    Wright, V.; Haslock, D. I.; Dowson, D.; Seller, P. C.; Reeves, B.

    1971-01-01

    Silicone 300 has been evaluated as an artificial lubricant in osteoarthrotic joints by means of a pilot study in five inpatients and a control trial of 25 outpatients with 40 osteoarthrotic knees. Sequential analysis showed a significant benefit from saline compared with silicone at one week follow-up and no significant difference at one month. Measurement of stiffness with a knee arthrograph showed no difference in reduction of stiffness between the two substances. In a study of 18 rabbits there was no evidence that silicone was retained in the joint cavity for longer than 48 hours. There was a failure of clearance of iodinated serum albumin for as long as three to four days after the injection of silicone, suggesting some obstruction to lymphatic outflow. Experimentally produced cartilaginous defects did not heal quicker with the injection of silicone into the joint. PMID:5575973

  4. Associations between lower extremity muscle mass and multiplanar knee laxity and stiffness: a potential explanation for sex differences in frontal and transverse plane knee laxity.

    PubMed

    Shultz, Sandra J; Pye, Michele L; Montgomery, Melissa M; Schmitz, Randy J

    2012-12-01

    Compared with men, women have disproportionally greater frontal (varus-valgus) and transverse (internal-external) plane laxity and lower stiffness, despite having similar sagittal (anterior-posterior) plane laxity and stiffness. While the underlying cause is unclear, the amount of lower extremity lean mass (LELM) may be a contributing factor. Lower extremity lean mass would be a stronger predictor of frontal and transverse plane laxity and incremental stiffness than the sagittal plane. Associations between LELM and stiffness would be stronger at lower force increments. Descriptive laboratory study. Sixty-three women and 30 men with no history of ligament injury were measured for knee laxity and incremental stiffness in the sagittal (-90- to 130-N posterior-to-anterior directed loads), frontal (±10-N·m varus-valgus torques), and transverse (±5-N·m internal-external rotation torques) planes and underwent dual-energy X-ray absorptiometry scans to measure LELM. Linear regressions examined the extent to which LELM predicted each laxity and stiffness value, while also accounting for a person's sex. Females (vs males) had greater laxity and less stiffness in the frontal and transverse planes but not the sagittal plane. Lower extremity lean mass was a poor predictor of sagittal laxity and stiffness (R (2) range = .021-.081; P > .06) but was a stronger predictor of frontal (R (2) range = .215-.567; P < .01) and transverse (R (2) range = .224-.356; P < .01) plane laxity and stiffness. Associations were stronger for low (R (2) = .495-.504) versus high (R (2) = .215-.435) frontal plane stiffness but were similar for low (R (2) = .233-.293) versus high (R (2) = .224-.356) transverse plane stiffness. Once we accounted for a person's LELM, sex had little effect on laxity and stiffness (change in R (2) after removal = .01-.08; P = .027-.797). Less LELM was associated with greater laxity and less stiffness in frontal and transverse planes, which may contribute to the disproportionally higher laxities and reduced stiffnesses observed in females in these planes. Frontal and transverse plane laxity and stiffness may be modifiable through strength training interventions that promote changes in muscle characteristics (eg, muscle cross-sectional area, stiffness) that may contribute to static knee joint stability, thus dynamic joint stability during sport activity.

  5. Application of shape memory alloy (SMA) spars for aircraft maneuver enhancement

    NASA Astrophysics Data System (ADS)

    Nam, Changho; Chattopadhyay, Aditi; Kim, Youdan

    2002-07-01

    Modern combat aircraft are required to achieve aggressive maneuverability and high agility performance, while maintaining handling qualities over a wide range of flight conditions. Recently, a new adaptive-structural concept called variable stiffness spar is proposed in order to increase the maneuverability of the flexible aircraft. The variable stiffness spar controls wing torsional stiffness to enhance roll performance in the complete flight envelope. However, variable stiffness spar requires the mechanical actuation system in order to rotate the Variable stiffness spar during flight. The mechanical actuation system to rotate variable stiffness spar may cause an additional weight increase. In this paper, we will apply Shape Memory Alloy (SMA) spars for aeroelastic performance enhancement. In order to explore the potential of SMA spar design, roll performance of the composite smart wings will be investigated using ASTROS. Parametric study will be conducted to investigate the SMA spar effects by changing the spar locations and geometry. The results show that with activation of the SMA spar, the roll effectiveness can be increased up to 61% compared with the baseline model.

  6. Development of VariLeg, an exoskeleton with variable stiffness actuation: first results and user evaluation from the CYBATHLON 2016.

    PubMed

    Schrade, Stefan O; Dätwyler, Katrin; Stücheli, Marius; Studer, Kathrin; Türk, Daniel-Alexander; Meboldt, Mirko; Gassert, Roger; Lambercy, Olivier

    2018-03-13

    Powered exoskeletons are a promising approach to restore the ability to walk after spinal cord injury (SCI). However, current exoskeletons remain limited in their walking speed and ability to support tasks of daily living, such as stair climbing or overcoming ramps. Moreover, training progress for such advanced mobility tasks is rarely reported in literature. The work presented here aims to demonstrate the basic functionality of the VariLeg exoskeleton and its ability to enable people with motor complete SCI to perform mobility tasks of daily life. VariLeg is a novel powered lower limb exoskeleton that enables adjustments to the compliance in the leg, with the objective of improving the robustness of walking on uneven terrain. This is achieved by an actuation system with variable mechanical stiffness in the knee joint, which was validated through test bench experiments. The feasibility and usability of the exoskeleton was tested with two paraplegic users with motor complete thoracic lesions at Th4 and Th12. The users trained three times a week, in 60 min sessions over four months with the aim of participating in the CYBATHLON 2016 competition, which served as a field test for the usability of the exoskeleton. The progress on basic walking skills and on advanced mobility tasks such as incline walking and stair climbing is reported. Within this first study, the exoskeleton was used with a constant knee stiffness. Test bench evaluation of the variable stiffness actuation system demonstrate that the stiffness could be rendered with an error lower than 30 Nm/rad. During training with the exoskeleton, both users acquired proficient skills in basic balancing, walking and slalom walking. In advanced mobility tasks, such as climbing ramps and stairs, only basic (needing support) to intermediate (able to perform task independently in 25% of the attempts) skill levels were achieved. After 4 months of training, one user competed at the CYBATHLON 2016 and was able to perform 3 (stand-sit-stand, slalom and tilted path) out of 6 obstacles of the track. No adverse events occurred during the training or the competition. Demonstration of the applicability to restore ambulation for people with motor complete SCI was achieved. The CYBATHLON highlighted the importance of training and gaining experience in piloting an exoskeleton, which were just as important as the technical realization of the robot.

  7. Physical Modeling of Shear Behavior of Infilled Rock Joints Under CNL and CNS Boundary Conditions

    NASA Astrophysics Data System (ADS)

    Shrivastava, Amit Kumar; Rao, K. Seshagiri

    2018-01-01

    Despite their frequent natural occurrence, filled discontinuities under constant normal stiffness (CNS) boundary conditions have been studied much less systematically, perhaps because of the difficulties arising from the increased number of variable parameters. Because of the lack of reliable and realistic theoretical or empirical relations and the difficulties in obtaining and testing representative samples, engineers rely on judgment and often consider the shear strength of the infilled material itself as shear strength of rock joints. This assumption leads to uneconomical and also sometimes the unsafe design of underground structures, slopes, rock-socketed piles and foundations. To study the effect of infill on the shear behavior of rock joints, tests were performed on the modeled infilled rock joint having different joint roughness under constant normal load (CNL) and CNS boundary conditions at various initial normal stress and varying thickness of the infilled material. The test results indicate that shear strength decreases with an increase in t/ a ratio for both CNL and CNS conditions, but the reduction in shear strength is more for CNL than for CNS condition for a given initial normal stress. The detailed account of the effect of thickness of infilled material on shear and deformation behavior of infilled rock joint is discussed in this paper, and a model is proposed to predict shear strength of infilled rock joint.

  8. The influence of landing mat composition on ankle injury risk during a gymnastic landing: a biomechanical quantification.

    PubMed

    Xiao, Xiaofei; Hao, Weiya; Li, Xuhong; Wan, Bingjun; Shan, Gongbing

    2017-01-01

    About 70% injury of gymnasts happened during landing - an interaction between gymnast and landing mat. The most injured joint is the ankle. The current study examined the effect of mechanical properties of landing mat on ankle loading with aims to identify means of decreasing the risk of ankle injury. Gymnastic skill - salto backward stretched with 3/2 twist was captured by two high-speed camcorders and digitized by using SIMI-Motion software. A subject-specific, 14-segment rigid-body model and a mechanical landing-mat model were built using BRG.LifeMODTM. The landings were simulated with varied landing-mat mechanical properties (i.e., stiffness, dampness and friction coefficients). Real landing performance could be accurately reproduced by the model. The simulations revealed that the ankle angle was relatively sensitive to stiffness and dampness of the landing mat, the ankle loading rate increased 26% when the stiffness was increased by 30%, and the changing of dampness had notable effect on horizontal ground reaction force and foot velocity. Further, the peak joint-reaction force and joint torque were more sensitive to friction than to stiffness and dampness of landing mat. Finally, ankle muscles would dissipate about twice energy (189%) when the friction was increased by 30%. Loads to ankles during landing would increase as the stiffness and dampness of the landing mat increase. Yet, increasing friction would cause a substantial rise of the ankle internal loads. As such, the friction should be a key factor influencing the risk of injury. Unfortunately, this key factor has rarely attracted attention in practice.

  9. Prevention of the Post-traumatic Fibrotic Response in Joints

    DTIC Science & Technology

    2014-10-01

    The American journal of forensic medicine and pathology . 1988; 9(4):310-2. 14 APPENDICES: An abstract submitted for the ORS conference...clinical problem of posttraumatic joint stiffness, a pathology that reduces the range of motion (ROM) of injured joints and contributes to the...development of osteoarthritis. The fundamental hypothesis that drives the current study is that pathological fibrotic response of injured joint tissues

  10. Regulation of step frequency in transtibial amputee endurance athletes using a running-specific prosthesis.

    PubMed

    Oudenhoven, Laura M; Boes, Judith M; Hak, Laura; Faber, Gert S; Houdijk, Han

    2017-01-25

    Running specific prostheses (RSP) are designed to replicate the spring-like behaviour of the human leg during running, by incorporating a real physical spring in the prosthesis. Leg stiffness is an important parameter in running as it is strongly related to step frequency and running economy. To be able to select a prosthesis that contributes to the required leg stiffness of the athlete, it needs to be known to what extent the behaviour of the prosthetic leg during running is dominated by the stiffness of the prosthesis or whether it can be regulated by adaptations of the residual joints. The aim of this study was to investigate whether and how athletes with an RSP could regulate leg stiffness during distance running at different step frequencies. Seven endurance runners with an unilateral transtibial amputation performed five running trials on a treadmill at a fixed speed, while different step frequencies were imposed (preferred step frequency (PSF) and -15%, -7.5%, +7.5% and +15% of PSF). Among others, step time, ground contact time, flight time, leg stiffness and joint kinetics were measured for both legs. In the intact leg, increasing step frequency was accompanied by a decrease in both contact and flight time, while in the prosthetic leg contact time remained constant and only flight time decreased. In accordance, leg stiffness increased in the intact leg, but not in the prosthetic leg. Although a substantial contribution of the residual leg to total leg stiffness was observed, this contribution did not change considerably with changing step frequency. Amputee athletes do not seem to be able to alter prosthetic leg stiffness to regulate step frequency during running. This invariant behaviour indicates that RSP stiffness has a large effect on total leg stiffness and therefore can have an important influence on running performance. Nevertheless, since prosthetic leg stiffness was considerably lower than stiffness of the RSP, compliance of the residual leg should not be ignored when selecting RSP stiffness. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Age and Sex Effects on the Active Stiffness of Vastus Intermedius under Isometric Contraction

    PubMed Central

    Wang, Cong-Zhi; Guo, Jing-Yi; Li, Tian-Jie; Shi, Wenxiu; Zheng, Yong-Ping

    2017-01-01

    Previously, a novel technique was proposed to quantify the relationship between the muscle stiffness and its nonfatigue contraction intensity. The method extended the measured range of isometric contraction to 100% maximum voluntary contraction (MVC) using an ultrasonic shear wave measurement setup. Yet, it has not been revealed how this relationship could be affected by factors like age or sex. To clarify these questions, vastus intermedius (VI) stiffness of 40 healthy subjects was assessed under 11 step levels of isometric contraction. The subjects were divided into four groups: young males, young females, elderly males, and elderly females (n = 10 for each). In a relaxed state, no significant difference was observed between the male and female subjects (p = 0.156) nor between the young and elderly subjects (p = 0.221). However, when performing isometric contraction, the VI stiffness of males was found to be significantly higher than that of females at the same level (p < 0.001), and that of the young was higher than the elderly (p < 0.001). Meanwhile, for two knee joint angles used, the stiffness measured at a 90° knee joint angle was always significantly larger than that measured at 60° (p < 0.001). Recognizing the active muscle stiffness of VI contributes to body stability, and these results may provide insight into the age and sex bias in musculoskeletal studies, such as those on fall risks. PMID:28473990

  12. Treatment with Ruta graveolens 5CH and Rhus toxicodendron 9CH may reduce joint pain and stiffness linked to aromatase inhibitors in women with early breast cancer: results of a pilot observational study.

    PubMed

    Karp, Jean-Claude; Sanchez, Carole; Guilbert, Philippe; Mina, William; Demonceaux, Antoine; Curé, Hervé

    2016-11-01

    To determine the possible effect of two homeopathic medicines, Ruta graveolens 5CH and Rhus toxicodendron 9CH, in the prevention of aromatase inhibitor (AI) associated joint pain and/or stiffness in women with early, hormone-receptor positive, breast cancer. This prospective, unrandomized observational study was carried out between April and October 2014. Women were recruited in two groups, according to which of the two study centres they attended: one receiving homeopathy in addition to standard treatment (group H) and a control group, receiving standard treatment (group C). All women were treated with an AI. In addition, women in group H also took Ruta graveolens 5CH and Rhus toxicodendron 9CH (5 granules, twice a day) up to 7 days before starting AI treatment. The homeopathic medicines were continued for 3 months. Demographic and clinical data were recorded using a self-assessment questionnaire at inclusion (T0) and 3 months (T3). Primary evaluation criteria were the evolution of scores for joint pain and stiffness, the impact of pain on sleep and analgesic consumption in the two groups after 3 months of treatment. Forty patients (mean age 64.9±8.1 years) were recruited, 20 in each group. Two-thirds of the patients had joint pain before starting AI treatment. There was a significant difference in the evolution of mean composite pain score between T0 and T3 in the two groups (-1.3 in group H vs. +3.4 in group C; p=0.0001). The individual components of the pain score (frequency, intensity and number of sites of pain) also decreased significantly in group H. Nine patients in group C (45%) vs. 1 (5%) in group H increased their analgesic consumption between T0 and T3 (p=0.0076). After 3 months of treatment, joint pain had a worse impact on sleep in patients in group C (35% vs. 0% of patients; p=0.0083). The differences observed in the evolution of morning and daytime stiffness between the two groups were smaller (p=0.053 and p=0.33, respectively), with the exception of time necessary for the disappearance of morning stiffness which was greater in group C (37.7±23.0 vs. 17.9±20.1 min; p=0.0173). These preliminary results suggest that treatment with Ruta graveolens 5CH and Rhus toxicodendron 9CH may decrease joint pain/stiffness in breast cancer patients treated with AIs. A larger-scale randomized study is required to confirm these results. Copyright © 2016 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  13. Quantifying anti-gravity torques for the design of a powered exoskeleton.

    PubMed

    Ragonesi, Daniel; Agrawal, Sunil K; Sample, Whitney; Rahman, Tariq

    2013-03-01

    Designing an upper extremity exoskeleton for people with arm weakness requires knowledge of the joint torques due to gravity and joint stiffness, as well as, active residual force capabilities of users. The objective of this research paper is to describe the characteristics of the upper limb of children with upper limb impairment. This paper describes the experimental measurements of the torque on the upper limb due to gravity and joint stiffness of three groups of subjects: able-bodied adults, able-bodied children, and children with neuromuscular disabilities. The experiment involves moving the arm to various positions in the sagittal plane and measuring the resultant force at the forearm. This force is then converted to torques at the elbow and shoulder. These data are compared to a two-link lumped mass model based on anthropomorphic data. Results show that the torques based on anthropometry deviate from experimentally measured torques as the arm goes through the range. Subjects with disabilities also maximally pushed and pulled against the force sensor to measure maximum strength as a function of arm orientation. For all subjects, the maximum voluntary applied torque at the shoulder and elbow in the sagittal plane was found to be lower than gravity torques throughout the disabled subjects' range of motion. This experiment informs designers of upper limb orthoses on the contribution of passive human joint torques due to gravity and joint stiffness and the strength capability of targeted users.

  14. Fetlock joint kinematics differ with age in Thoroughbred [was thoroughbred] racehorses.

    PubMed

    Butcher, Michael T; Ashley-Ross, M A

    2002-05-01

    Fetlock joint kinematics during galloping in 2-, 3-, 4-, and 5-year-old Thoroughbreds in race training were quantified to determine if differences due to age could account for the observation that 2-year old Thoroughbred racehorses incur a high number of injuries to the bones and soft tissues in the distal forelimbs during training and at the outset of racing. Twelve Thoroughbred racehorses were videotaped in the sagittal plane at 250 frames/s during their daily galloping workout on a 7/8 mile sand-surface training track. Four galloping strides were recorded for each horse and subsequently digitized to determine fetlock joint angles of the leading forelimb during the limb support period of a stride. Four kinematic variables were measured from each stride's angular profile: angle of fetlock joint dorsi-flexion at mid-stance, negative angular velocity, positive angular velocity and time from hoof impact to mid-stance phase of limb support. The 2-year old Thoroughbreds had significantly quicker rates of dorsi-flexion of their fetlock joints than 3- (p=0.01), 4- (p=0.01), and 5-year old (p<0.01) Thoroughbreds following impact of the leading forelimb during moderate galloping (avg. 14 m/s). Higher rates of dorsi-flexion in young Thoroughbreds may reflect immaturity (lack of stiffness) of the suspensory apparatus tissues.

  15. Influences of Patellofemoral Pain and Fatigue in Female Dancers during Ballet Jump-Landing.

    PubMed

    Peng, H-T; Chen, W C; Kernozek, T W; Kim, K; Song, C-Y

    2015-08-01

    This study investigated the influence of patellofemoral pain (PFP) and fatigue on lower-extremity joint biomechanics in female dancers during consecutive simple ground échappé. 3-dimensional joint mechanics were analyzed from the no-fatigue to fatigue conditions. 2-way mixed ANOVAs were used to compare the differences of the kinematic and kinetic variables between groups and conditions. Group main effects were seen in increased jump height (p=0.03), peak vertical ground reaction force (p=0.01), knee joint power absorption (p=0.04), and patellofemoral joint stress (PFJS, p=0.04) for PFP group. Fatigue main effects were found for decreased jump height (p<0.01), decreased ankle plantarflexion at initial foot-ground contact (p=0.01), and decreased ankle displacement (p<0.01). Hip external rotation impulse and hip joint stiffness increased (both p<0.01) while knee extension and external rotation moment, and ankle joint power absorption decreased (p<0.01, p=0.02, p<0.01, respectively) after fatigue. The peak PFJS also decreased after fatigue (p<0.01). Female ballet dancers with PFP sustained great ground impact and loads on the knee probably due to higher jump height compared to the controls. All dancers presented diminished knee joint loading for the protective mechanism and endurance of ankle joint musculature required for the dissipation of loads and displayed a distal-to-proximal dissipation strategy after fatigue. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Integral abutment bridge for Louisiana's soft and stiff soils.

    DOT National Transportation Integrated Search

    2016-03-01

    Integral abutment bridges (IABs) have been designed and constructed in a few US states in the past few : decades. The initial purpose of building such bridges was to eliminate the expansion joints and resolve the : joint-induced problems. Although IA...

  17. Variable Stiffness Panel Structural Analyses With Material Nonlinearity and Correlation With Tests

    NASA Technical Reports Server (NTRS)

    Wu, K. Chauncey; Gurdal, Zafer

    2006-01-01

    Results from structural analyses of three tow-placed AS4/977-3 composite panels with both geometric and material nonlinearities are presented. Two of the panels have variable stiffness layups where the fiber orientation angle varies as a continuous function of location on the panel planform. One variable stiffness panel has overlapping tow bands of varying thickness, while the other has a theoretically uniform thickness. The third panel has a conventional uniform-thickness [plus or minus 45](sub 5s) layup with straight fibers, providing a baseline for comparing the performance of the variable stiffness panels. Parametric finite element analyses including nonlinear material shear are first compared with material characterization test results for two orthotropic layups. This nonlinear material model is incorporated into structural analysis models of the variable stiffness and baseline panels with applied end shortenings. Measured geometric imperfections and mechanical prestresses, generated by forcing the variable stiffness panels from their cured anticlastic shapes into their flatter test configurations, are also modeled. Results of these structural analyses are then compared to the measured panel structural response. Good correlation is observed between the analysis results and displacement test data throughout deep postbuckling up to global failure, suggesting that nonlinear material behavior is an important component of the actual panel structural response.

  18. Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    PubMed

    Facchinello, Yann; Brailovski, Vladimir; Petit, Yvan; Mac-Thiong, Jean-Marc

    2014-11-01

    The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted from this thermal treatment are numerically modeled and experimentally measured. To illustrate the possible applications of such a modeling approach, two case studies are presented: (a) optimization of the Joule-heating strategy to reduce annealing time, and (b) modulation of the rod's overall flexural stiffness using partial annealing. A numerical model of a human spine coupled with the model of the variable flexural stiffness spinal rod developed in this work can ultimately be used to maximize the stabilization capability of spinal instrumentation, while simultaneously decreasing the risks associated with spinal fusion. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Use of a Multivector Mandibular Distractor for Treatment of Pediatric Proximal Interphalangeal Joint Pilon Fractures: A Case-Based Review.

    PubMed

    Pedreira, Rachel; Cho, Brian H; Geer, Angela; DeJesus, Ramon A

    2018-04-01

    The difficulties in surgical treatment of pilon fractures of the finger include fragment reconstitution and posthealing stiffness. In adults, external fixation with traction and early active range of motion (AROM)/passive range of motion (PROM) during healing is considered necessary for avoiding joint stiffness and attaining realignment. The authors present a unique approach to pediatric pilon fractures that uses open reduction and multivector external fixation with delayed AROM/PROM. Initial immobilization and significant traction allowed for joint realignment and prevented noncompliance with staged distraction. The authors believe this immobilization leads to a superior outcome because, unlike adults, children tend to avoid stiffness and a larger distraction force allowed for sufficient joint realignment to regain range of motion (ROM). A right-handed 13-year-old boy sustained a right ring finger fracture and presented 12 days later. Radiographs revealed a comminuted Salter-Harris 4 fracture of the middle phalanx. The patient underwent open reduction and placement of multivector external fixation using a pediatric mandibular distractor/fixator. Significant traction was applied to distract the finger to length. Hardware was removed 6 weeks postoperatively and AROM was initiated after splinting. The patient started PROM 8 weeks postoperatively. Strengthening was initiated 2 weeks later. ROM improved and rehabilitation was continued. The patient exhibited nearly equal grip strength 12 weeks postoperatively. At 14 months follow-up, radiographs showed complete healing and joint realignment. There was no deformity or pain and finger length was restored. Management of pediatric pilon fractures is rarely described and presents unique considerations. Early-stage traction and immobilization using a multivector mandibular fixator/distractor is suitable in a child because noncompliance is avoided and there is a decreased risk for stiffness. Combining early immobilization with subsequent-staged AROM, PROM, and strengthening resulted in no loss of ROM and maintained articular symmetry.

  20. Effect of sex and fatigue on muscle stiffness and musculoarticular stiffness of the knee joint in a young active population.

    PubMed

    Wang, Dan; De Vito, Giuseppe; Ditroilo, Massimiliano; Delahunt, Eamonn

    2017-08-01

    The purpose of this study was to investigate the influence of sex and fatigue on knee extensor peak torque (PT), muscle stiffness (MS) of the vastus lateralis (VL) and knee joint musculoarticular stiffness (MAS) in young adults. Twenty-two male and 22 female recreational athletes participated. Males were characterised by higher relaxed [pre-: males 364.43 (52.00) N · m -1 , females 270.27 (37.25) N · m -1 ; post-: males 446.75 (83.27) N · m -1 , females 307.39 (38.58) N · m -1 ] and contracted [pre-: males 495.07 (71.04) N · m -1 , females 332.34 (85.42) N · m -1 ; post-: males 546.37 (90.74) N · m -1 , females 349.21 (85.55) N · m -1 ] MS of the VL, and knee joint MAS [pre-: males 1450.11 (507.98) N · m -1 , females 1027.99 (227.33) N · m -1 ; post-: males 1345.81 (404.90) N · m -1 , females 952.78 (192.38) N · m -1 ] than females pre- and post-fatigue. A similar finding was observed in pre-fatigue normalised knee extensor PT [pre-: males 2.77 (0.42) N · m kg -1 , females 2.41 (0.40) N · m kg -1 , post-: males 2.53 (0.54) N · m kg -1 , females 2.26 (0.44) N · m kg -1 ]. After the fatigue protocol, normalised knee extensor PT and knee joint MAS decreased, whilst relaxed and contracted MS of the VL increased in both sexes. These observed differences may contribute to the higher risk of knee injury in females and following the onset of fatigue.

  1. Stance controlled knee flexion improves stimulation driven walking after spinal cord injury

    PubMed Central

    2013-01-01

    Background Functional neuromuscular stimulation (FNS) restores walking function after paralysis from spinal cord injury via electrical activation of muscles in a coordinated fashion. Combining FNS with a controllable orthosis to create a hybrid neuroprosthesis (HNP) has the potential to extend walking distance and time by mechanically locking the knee joint during stance to allow knee extensor muscle to rest with stimulation turned off. Recent efforts have focused on creating advanced HNPs which couple joint motion (e.g., hip and knee or knee and ankle) to improve joint coordination during swing phase while maintaining a stiff-leg during stance phase. Methods The goal of this study was to investigate the effects of incorporating stance controlled knee flexion during loading response and pre-swing phases on restored gait. Knee control in the HNP was achieved by a specially designed variable impedance knee mechanism (VIKM). One subject with a T7 level spinal cord injury was enrolled and served as his own control in examining two techniques to restore level over-ground walking: FNS-only (which retained a stiff knee during stance) and VIKM-HNP (which allowed controlled knee motion during stance). The stimulation pattern driving the walking motion remained the same for both techniques; the only difference was that knee extensor stimulation was constant during stance with FNS-only and modulated together with the VIKM to control knee motion during stance with VIKM-HNP. Results Stance phase knee angle was more natural during VIKM-HNP gait while knee hyperextension persisted during stiff-legged FNS-only walking. During loading response phase, vertical ground reaction force was less impulsive and instantaneous gait speed was increased with VIKM-HNP, suggesting that knee flexion assisted in weight transfer to the leading limb. Enhanced knee flexion during pre-swing phase also aided flexion during swing, especially when response to stimulation was compromised. Conclusions These results show the potential advantages of incorporating stance controlled knee flexion into a hybrid neuroprosthesis for walking. The addition of such control to FNS driven walking could also enable non-level walking tasks such as uneven terrain, slope navigation and stair descent where controlled knee flexion during weight bearing is critical. PMID:23826711

  2. Optimization of prosthetic foot stiffness to reduce metabolic cost and intact knee loading during below-knee amputee walking: a theoretical study.

    PubMed

    Fey, Nicholas P; Klute, Glenn K; Neptune, Richard R

    2012-11-01

    Unilateral below-knee amputees develop abnormal gait characteristics that include bilateral asymmetries and an elevated metabolic cost relative to non-amputees. In addition, long-term prosthesis use has been linked to an increased prevalence of joint pain and osteoarthritis in the intact leg knee. To improve amputee mobility, prosthetic feet that utilize elastic energy storage and return (ESAR) have been designed, which perform important biomechanical functions such as providing body support and forward propulsion. However, the prescription of appropriate design characteristics (e.g., stiffness) is not well-defined since its influence on foot function and important in vivo biomechanical quantities such as metabolic cost and joint loading remain unclear. The design of feet that improve these quantities could provide considerable advancements in amputee care. Therefore, the purpose of this study was to couple design optimization with dynamic simulations of amputee walking to identify the optimal foot stiffness that minimizes metabolic cost and intact knee joint loading. A musculoskeletal model and distributed stiffness ESAR prosthetic foot model were developed to generate muscle-actuated forward dynamics simulations of amputee walking. Dynamic optimization was used to solve for the optimal muscle excitation patterns and foot stiffness profile that produced simulations that tracked experimental amputee walking data while minimizing metabolic cost and intact leg internal knee contact forces. Muscle and foot function were evaluated by calculating their contributions to the important walking subtasks of body support, forward propulsion and leg swing. The analyses showed that altering a nominal prosthetic foot stiffness distribution by stiffening the toe and mid-foot while making the ankle and heel less stiff improved ESAR foot performance by offloading the intact knee during early to mid-stance of the intact leg and reducing metabolic cost. The optimal design also provided moderate braking and body support during the first half of residual leg stance, while increasing the prosthesis contributions to forward propulsion and body support during the second half of residual leg stance. Future work will be directed at experimentally validating these results, which have important implications for future designs of prosthetic feet that could significantly improve amputee care.

  3. Close-wedge osteotomy for bony locking stiffness of the elbow in Gorham disease patients: a case report.

    PubMed

    Wang, Hsien-Chung; Lin, Gau-Tyan

    2004-05-01

    Gorham disease is a so-called massive idiopathic osteolysis or vanishing bone disorder. Massive osteolysis remains an enigmatic condition that involves various skeletal locations and is caused by endothelial proliferation. The diagnosis is difficult and is established via the association of clinical, radiologic and histologic pictures. Treatment modalities yield variable results. We report a case of vanishing bone in the elbow joint and carpal bones following trauma. This 13-year-old boy complained of severe restricted motion and deformity of the right elbow. We managed the problem using arthroplasty with close-wedge osteotomy on the lateral condyle of the humerus.

  4. Development of an Intelligent Stretching Device for Ankle Joints With Contracture/Spasticity

    DTIC Science & Technology

    2001-10-25

    percentage corresponded to background dorsi-flexion muscle contraction and 0% was the relaxed state. Next, tendon reflexes were evaluated...the representative cases, joint stiffness was reduced markedly after stretching across the range of muscle contraction (Fig. 5), including both

  5. Sway‐dependent changes in standing ankle stiffness caused by muscle thixotropy

    PubMed Central

    Sakanaka, Tania E.; Lakie, Martin

    2016-01-01

    Key points The passive stiffness of the calf muscles contributes to standing balance, although the properties of muscle tissue are highly labile.We investigated the effect of sway history upon intrinsic ankle stiffness and demonstrated reductions in stiffness of up to 43% during conditions of increased baseline sway.This sway dependence was most apparent when using low amplitude stiffness‐measuring perturbations, and the short‐range stiffness component was smaller during periods of high sway.These characteristics are consistent with the thixotropic properties of the calf muscles causing the observed changes in ankle stiffness.Periods of increased sway impair the passive stabilization of standing, demanding more active neural control of balance. Abstract Quiet standing is achieved through a combination of active and passive mechanisms, consisting of neural control and intrinsic mechanical stiffness of the ankle joint, respectively. The mechanical stiffness is partly determined by the calf muscles. However, the viscoelastic properties of muscle are highly labile, exhibiting a strong dependence on movement history. By measuring the effect of sway history upon ankle stiffness, the present study determines whether this lability has consequences for the passive stabilization of human standing. Ten subjects stood quietly on a rotating platform whose axis was collinear with the ankle joint. Ankle sway was increased by slowly tilting this platform in a random fashion, or decreased by fixing the body to a board. Ankle stiffness was measured by using the same platform to simultaneously apply small, brief perturbations (<0.6 deg; 140 ms) at the same time as the resulting torque response was recorded. The results show that increasing sway reduces ankle stiffness by up to 43% compared to the body‐fixed condition. Normal quiet stance was associated with intermediate values. The effect was most apparent when using smaller perturbation amplitudes to measure stiffness (0.1 vs. 0.6 deg). Furthermore, torque responses exhibited a biphasic pattern, consisting of an initial steep rise followed by a shallower increase. This transition occurred earlier during increased levels of ankle sway. These results are consistent with a movement‐dependent change in passive ankle stiffness caused by thixotropic properties of the calf muscle. The consequence is to place increased reliance upon active neural control during times when increased sway renders ankle stiffness low. PMID:26607292

  6. Dynamically variable negative stiffness structures

    PubMed Central

    Churchill, Christopher B.; Shahan, David W.; Smith, Sloan P.; Keefe, Andrew C.; McKnight, Geoffrey P.

    2016-01-01

    Variable stiffness structures that enable a wide range of efficient load-bearing and dexterous activity are ubiquitous in mammalian musculoskeletal systems but are rare in engineered systems because of their complexity, power, and cost. We present a new negative stiffness–based load-bearing structure with dynamically tunable stiffness. Negative stiffness, traditionally used to achieve novel response from passive structures, is a powerful tool to achieve dynamic stiffness changes when configured with an active component. Using relatively simple hardware and low-power, low-frequency actuation, we show an assembly capable of fast (<10 ms) and useful (>100×) dynamic stiffness control. This approach mitigates limitations of conventional tunable stiffness structures that exhibit either small (<30%) stiffness change, high friction, poor load/torque transmission at low stiffness, or high power active control at the frequencies of interest. We experimentally demonstrate actively tunable vibration isolation and stiffness tuning independent of supported loads, enhancing applications such as humanoid robotic limbs and lightweight adaptive vibration isolators. PMID:26989771

  7. Experimental measure of arm stiffness during single reaching movements with a time-frequency analysis

    PubMed Central

    Pierobon, Alberto; DiZio, Paul; Lackner, James R.

    2013-01-01

    We tested an innovative method to estimate joint stiffness and damping during multijoint unfettered arm movements. The technique employs impulsive perturbations and a time-frequency analysis to estimate the arm's mechanical properties along a reaching trajectory. Each single impulsive perturbation provides a continuous estimation on a single-reach basis, making our method ideal to investigate motor adaptation in the presence of force fields and to study the control of movement in impaired individuals with limited kinematic repeatability. In contrast with previous dynamic stiffness studies, we found that stiffness varies during movement, achieving levels higher than during static postural control. High stiffness was associated with elevated reflexive activity. We observed a decrease in stiffness and a marked reduction in long-latency reflexes around the reaching movement velocity peak. This pattern could partly explain the difference between the high stiffness reported in postural studies and the low stiffness measured in dynamic estimation studies, where perturbations are typically applied near the peak velocity point. PMID:23945781

  8. Reduced-order modeling approach for frictional stick-slip behaviors of joint interface

    NASA Astrophysics Data System (ADS)

    Wang, Dong; Xu, Chao; Fan, Xuanhua; Wan, Qiang

    2018-03-01

    The complex frictional stick-slip behaviors of mechanical joint interface have a great effect on the dynamic properties of assembled structures. In this paper, a reduced-order modeling approach based on the constitutive Iwan model is proposed to describe the stick-slip behaviors of joint interface. An improved Iwan model is developed to describe the non-zero residual stiffness at macro-slip regime and smooth transition of joint stiffness from micro-slip to macro-slip regime, and the power-law relationship of energy dissipation during the micro-slip regime. In allusion to these nonlinear behaviors, the finite element method is used to calculate the recycle force under monolithic loading and the energy dissipation per cycle under oscillatory loading. The proposed model is then used to predict the nonlinear stick-slip behaviors of joint interface by curve-fitting to the results of finite element analysis, and the results show good agreements with the finite element analysis. A comparison with the experiment results in literature is also made. The proposed model agrees very well with the experiment results.

  9. Heavily loaded joints for assembling aerobrake support trusses

    NASA Technical Reports Server (NTRS)

    Bandel, Hannskarl; Olsson, Nils; Levintov, Boris

    1990-01-01

    The major emphasis was to develop erectable joints for large aerobrake support trusses. The truss joints must be able to withstand the large forces experienced by the truss during the aero-pass, as well as be easily assembled and disassembled on orbit by astronauts or robots. Other important design considerations include; strength, stiffness, and allowable error in strut length. Six mechanical joint designs, as well as a seventh joint design, where a high strength epoxy is injected to make the connection rigid, are presented.

  10. Artificial atlanto-odontoid joint replacement through a transoral approach.

    PubMed

    Lu, Bin; He, Xi Jing; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2009-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \\ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities.

  11. Artificial atlanto-odontoid joint replacement through a transoral approach

    PubMed Central

    Lu, Bin; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2008-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1–C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P ≤ 0.021) and NZ (P ≤ 0.002) and a significantly increased stiffness (P < 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P ≥ 0.719), NZ (P ≥ 0.580), and stiffness (P ≥ 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities. PMID:19043745

  12. The gearing function of running shoe longitudinal bending stiffness.

    PubMed

    Willwacher, Steffen; König, Manuel; Braunstein, Björn; Goldmann, Jan-Peter; Brüggemann, Gert-Peter

    2014-07-01

    The purpose of the present study was to investigate whether altered longitudinal bending stiffness (LBS) levels of the midsole of a running shoe lead to a systematic change in lower extremity joint lever arms of the ground reaction force (GRF). Joint moments and GRF lever arms in the sagittal plane were determined from 19 male subjects running at 3.5 m/s using inverse dynamics procedures. LBS was manipulated using carbon fiber insoles of 1.9 mm and 3.2 mm thickness. Increasing LBS led to a significant shift of joint lever arms to a more anterior position. Effects were more pronounced at distal joints. Ankle joint moments were not significantly increased in the presence of higher GRF lever arms when averaged over all subjects. Still, two individual strategies (1: increase ankle joint moments while keeping push-off times almost constant, 2: decrease ankle joint moments and increase push-off times) could be identified in response to increased ankle joint lever arms that might reflect individual differences between subjects with respect to strength capacities or anthropometric characteristics. The results of the present study indicate that LBS systematically influences GRF lever arms of lower extremity joints during the push-off phase in running. Further, individual responses to altered LBS levels could be identified that could aid in finding optimum LBS values for a given individual. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. The behavior of bonded doubler splices for composite sandwich panels

    NASA Technical Reports Server (NTRS)

    Zeller, T. A.; Weisahaar, T. A.

    1980-01-01

    The results of an investigation into the behavior of adhesively bonded doubler splices of two composite material sandwich panels are presented. The splices are studied from three approaches: analytical; numerical (finite elements); and experimental. Several parameters that characterize the splice are developed to determine their influence upon joint strength. These parameters are: doubler overlap length; core stiffness; laminate bending stiffness; the size of the gap between the spliced sandwich panels; and room and elevated temperatures. Similarities and contrasts between these splices and the physically similar single and double lap joints are discussed. The results of this investigation suggest several possible approaches to improving the strength of the sandwich splices.

  14. Optimal compliant-surface jumping: a multi-segment model of springboard standing jumps.

    PubMed

    Cheng, Kuangyou B; Hubbard, Mont

    2005-09-01

    A multi-segment model is used to investigate optimal compliant-surface jumping strategies and is applied to springboard standing jumps. The human model has four segments representing the feet, shanks, thighs, and trunk-head-arms. A rigid bar with a rotational spring on one end and a point mass on the other end (the tip) models the springboard. Board tip mass, length, and stiffness are functions of the fulcrum setting. Body segments and board tip are connected by frictionless hinge joints and are driven by joint torque actuators at the ankle, knee, and hip. One constant (maximum isometric torque) and three variable functions (of instantaneous joint angle, angular velocity, and activation level) determine each joint torque. Movement from a nearly straight motionless initial posture to jump takeoff is simulated. The objective is to find joint torque activation patterns during board contact so that jump height can be maximized. Minimum and maximum joint angles, rates of change of normalized activation levels, and contact duration are constrained. Optimal springboard jumping simulations can reasonably predict jumper vertical velocity and jump height. Qualitatively similar joint torque activation patterns are found over different fulcrum settings. Different from rigid-surface jumping where maximal activation is maintained until takeoff, joint activation decreases near takeoff in compliant-surface jumping. The fulcrum-height relations in experimental data were predicted by the models. However, lack of practice at non-preferred fulcrum settings might have caused less jump height than the models' prediction. Larger fulcrum numbers are beneficial for taller/heavier jumpers because they need more time to extend joints.

  15. Telemetric ambulatory arterial stiffness index, a predictor of cardio-cerebro-vascular mortality, is associated with aortic stiffness-determining factors.

    PubMed

    Li, Zhi-Yong; Xu, Tian-Ying; Zhang, Sai-Long; Zhou, Xiao-Ming; Xu, Xue-Wen; Guan, Yun-Feng; Lo, Ming; Miao, Chao-Yu

    2013-09-01

    Ambulatory arterial stiffness index (AASI) has been proposed as a new measure of arterial stiffness for predicting cardio-cerebro-vascular morbidity and mortality. However, there has been no research on the direct relationships between AASI and arterial stiffness-determining factors. We utilized beat-to-beat intra-aortic blood pressure (BP) telemetry to characterize AASI in Wistar-Kyoto (WKY) and spontaneously hypertensive rats (SHR). By determination of aortic structural components and analysis of their correlations with AASI, we provided the first direct evidence for the associations between AASI and arterial stiffness-determining factors including the collagen content and collagen/elastin. Ambulatory arterial stiffness index was positively correlated with pulse pressure in both WKY and SHR, less dependent on BP and BP variability than pulse pressure, and relatively stable, especially the number of BP readings not less than ~36. The correlations between AASI and aortic components were comparable for various AASI values derived from BP readings not less than ~36. Not only AASI but also BP variability and pulse pressure demonstrated a direct relationship with arterial stiffness. These findings indicate AASI may become a routine measure in human arterial stiffness assessment. It is recommended to use a cluster of parameters such as AASI, BP variability, and pulse pressure for evaluating arterial stiffness. © 2013 John Wiley & Sons Ltd.

  16. Quantifying the variability in stiffness and damping of an automotive vehicle's trim-structure mounts

    NASA Astrophysics Data System (ADS)

    Abolfathi, Ali; O'Boy, Dan J.; Walsh, Stephen J.; Dowsett, Amy; Fisher, Stephen A.

    2016-09-01

    Small plastic clips are used in large numbers in automotive vehicles to connect interior trims to vehicle structures. The variability in their properties can contribute to the overall variability in noise and vibration response of the vehicle. The variability arises due to their material and manufacturing tolerances and more importantly due to the boundary condition. To measure their stiffness and damping, a simple experimental rig is used where a mass is supported by the clip which is modelled as a single degree of freedom system. The rig is designed in a way that it simulates the boundary condition as those of the real vehicle. The variability in clip and also due to the boundary condition at the structure side is first examined which is 7% for stiffness and 8% for damping. To simulate the connection of the trim side, a mount is built using a 3D printer. Rattling occurs in the response of the clips with loose connections, however by preloading the mount the effective stiffness increases and the rattling is eliminated. The variability due to the boundary condition at the trim side was as large as 40% for stiffness and 52% for damping.

  17. Electrical stimulation on joint contracture: an experiment in rat model with direct current.

    PubMed

    Akai, M; Shirasaki, Y; Tateishi, T

    1997-04-01

    To examine whether electrical stimulation could decrease the degree of joint stiffness in a rat lower extremity model. Rat knee joints were surgically immobilized in a flexed position for 3 weeks. Two groups of rats were stimulated with 20 microA and 50 microA constant direct current. Another group had surgical intervention and sham electrodes without electricity. The hind leg was extirpated and prepared for a sample with the femur-knee joint-tibia unit. Recording the knee flexion angle with extension torque, the degree of joint contracture was assessed biomechanically by measuring the bone-joint-bone sample as a cantilever. Measurement was performed with (1) spectral analysis of transfer function measurement using random mechanical noise with frequency range from 1 to 50Hz, and (2) dynamic stiffness and loss tangent with steady-state sinusoidal excitation (11 and 35Hz). The results showed that no significant difference or trend was found in vibration analysis among three groups. However, spectral analysis of transfer function measurement revealed more deformation against load, and more viscous nature in the stimulation groups, especially in low frequency band, than in the sham group. Electrical stimulation with constant direct current has a possibility of reducing the degree of joint contracture.

  18. A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.

    PubMed

    De Falco, Iris; Culmone, Costanza; Menciassi, Arianna; Dankelman, Jenny; van den Dobbelsteen, John J

    2018-06-04

    Needles are advanced tools commonly used in minimally invasive medical procedures. The accurate manoeuvrability of flexible needles through soft tissues is strongly determined by variations in tissue stiffness, which affects the needle-tissue interaction and thus causes needle deflection. This work presents a variable stiffness mechanism for percutaneous needles capable of compensating for variations in tissue stiffness and undesirable trajectory changes. It is composed of compliant segments and rigid plates alternately connected in series and longitudinally crossed by four cables. The tensioning of the cables allows the omnidirectional steering of the tip and the stiffness tuning of the needle. The mechanism was tested separately under different working conditions, demonstrating a capability to exert up to 3.6 N. Afterwards, the mechanism was integrated into a needle, and the overall device was tested in gelatine phantoms simulating the stiffness of biological tissues. The needle demonstrated the capability to vary deflection (from 11.6 to 4.4 mm) and adapt to the inhomogeneity of the phantoms (from 21 to 80 kPa) depending on the activation of the variable stiffness mechanism. Graphical abstract ᅟ.

  19. Design optimization of dual-axis driving mechanism for satellite antenna with two planar revolute clearance joints

    NASA Astrophysics Data System (ADS)

    Bai, Zheng Feng; Zhao, Ji Jun; Chen, Jun; Zhao, Yang

    2018-03-01

    In the dynamic analysis of satellite antenna dual-axis driving mechanism, it is usually assumed that the joints are ideal or perfect without clearances. However, in reality, clearances in joints are unavoidable due to assemblage, manufacturing errors and wear. When clearance is introduced to the mechanism, it will lead to poor dynamic performances and undesirable vibrations due to impact forces in clearance joint. In this paper, a design optimization method is presented to reduce the undesirable vibrations of satellite antenna considering clearance joints in dual-axis driving mechanism. The contact force model in clearance joint is established using a nonlinear spring-damper model and the friction effect is considered using a modified Coulomb friction model. Firstly, the effects of clearances on dynamic responses of satellite antenna are investigated. Then the optimization method for dynamic design of the dual-axis driving mechanism with clearance is presented. The objective of the optimization is to minimize the maximum absolute vibration peak of antenna acceleration by reducing the impact forces in clearance joint. The main consideration here is to optimize the contact parameters of the joint elements. The contact stiffness coefficient, damping coefficient and the dynamic friction coefficient for clearance joint elements are taken as the optimization variables. A Generalized Reduced Gradient (GRG) algorithm is used to solve this highly nonlinear optimization problem for dual-axis driving mechanism with clearance joints. The results show that the acceleration peaks of satellite antenna and contact forces in clearance joints are reduced obviously after design optimization, which contributes to a better performance of the satellite antenna. Also, the application and limitation of the proposed optimization method are discussed.

  20. Advanced joining concepts for passive vibration control

    NASA Technical Reports Server (NTRS)

    Prucz, Jacky C.; Spyrakos, Constantine

    1987-01-01

    A comprehensive parametric study was carried out to establish design guidelines for favorable tradeoffs between damping benefits and the associated stiffness, strength and weight penalties in a rhombic joint. The results are compared with the corresponding tradeoffs for a double-lap joint made of the same materials.

  1. Fuzzy variable impedance control based on stiffness identification for human-robot cooperation

    NASA Astrophysics Data System (ADS)

    Mao, Dachao; Yang, Wenlong; Du, Zhijiang

    2017-06-01

    This paper presents a dynamic fuzzy variable impedance control algorithm for human-robot cooperation. In order to estimate the intention of human for co-manipulation, a fuzzy inference system is set up to adjust the impedance parameter. Aiming at regulating the output fuzzy universe based on the human arm’s stiffness, an online stiffness identification method is developed. A drag interaction task is conducted on a 5-DOF robot with variable impedance control. Experimental results demonstrate that the proposed algorithm is superior.

  2. A variable stiffness dielectric elastomer actuator based on electrostatic chucking.

    PubMed

    Imamura, Hiroya; Kadooka, Kevin; Taya, Minoru

    2017-05-14

    Dielectric elastomer actuators (DEA) are one type of promising artificial muscle; however, applications of bending-type DEA for robotic end-effectors may be limited by their low stiffness and ability to resist external loads without buckling. Unimorph DEA can produce large out-of-plane deformation suitable for use as robotic end effectors; however, design of such actuators for large displacement comes at the cost of low stiffness and blocking force. This work proposes and demonstrates a variable stiffness dielectric elastomer actuator (VSDEA) consisting of a plurality of unimorph DEA units operating in parallel, which can exhibit variable electrostatic chucking to modulate the structure's bending stiffness. The unimorph DEA units are additively manufactured using a high-resolution pneumatic dispenser, and VSDEA comprising various numbers of units are assembled. The performance of the DEA units and VSDEA are compared to model predictions, exhibiting a maximum stiffness change of 39.2×. A claw actuator comprising two VSDEA and weighing 0.6 grams is demonstrated grasping and lifting a 10 gram object.

  3. Variable stiffness sandwich panels using electrostatic interlocking core

    NASA Astrophysics Data System (ADS)

    Heath, Callum J. C.; Bond, Ian P.; Potter, Kevin D.

    2016-04-01

    Structural topology has a large impact on the flexural stiffness of a beam structure. Reversible attachment between discrete substructures allows for control of shear stress transfer between structural elements, thus stiffness modulation. Electrostatic adhesion has shown promise for providing a reversible latching mechanism for controllable internal connectivity. Building on previous research, a thin film copper polyimide laminate has been used to incorporate high voltage electrodes to Fibre Reinforced Polymer (FRP) sandwich structures. The level of electrostatic holding force across the electrode interface is key to the achievable level of stiffness modulation. The use of non-flat interlocking core structures can allow for a significant increase in electrode contact area for a given core geometry, thus a greater electrostatic holding force. Interlocking core geometries based on cosine waves can be Computer Numerical Control (CNC) machined from Rohacell IGF 110 Foam core. These Interlocking Core structures could allow for enhanced variable stiffness functionality compared to basic planar electrodes. This novel concept could open up potential new applications for electrostatically induced variable stiffness structures.

  4. [Restricted motion after total knee arthroplasty].

    PubMed

    Kucera, T; Urban, K; Karpas, K; Sponer, P

    2007-10-01

    The aim of the study was to ascertain what proportion of patients undergoing total knee arthroplasty (TKA) complain of restricted knee joint motion, and to investigate options for improvement of this situation. Our evaluation included a group of 796 patients treated with TKA at our department in the period from January 1, 1990, to December 31, 2004. In all cases, a condylar implant with preservation of the posterior cruciate ligaments was used. In addition to medical history, the range of motion, knee joint malalignment and radiological findings were assessed before surgery. After THA, the type of implant and complications, if any, were recorded, and improvement in joint motion was followed up. Based on the results of Kim et al., flexion contracture equal to or higher than 15 degrees and/or flexion less than 75 degrees were made the criteria of stiffness after THA. Patients with restricted THA motion who had aseptic or septic implant loosening were not included. Of the 796 evaluated patients, 32 (4.14 %) showed restricted motion after total knee arthroplasty, as assessed by the established criteria. In 16 patients, stiffness defined by these criteria had existed before surgery, and three patients showed an excessive production of adhesions and heterotopic ossifications. In three patients, the implantation procedure resulted in an elevated level of the original joint line and subsequent development of patella infera and increased tension of the posterior cruciate ligament. Four patients declined physical therapy and, in six, the main cause of stiffness could not be found. Seventeen patients did not require surgical therapy for restricted motion; TKA provided significant pain relief and they considered the range of motion achieved to be sufficient. One patient underwent redress 3 months after surgery, but with no success. Repeated releases of adhesions, replacement of a polyethylene liner and revision surgery of the extensor knee structures were performed in 15 patients. In these, the average value of knee flexion increased by 17 degrees only and, in the patients suffering from excessive adhesion production, this value remained almost unchanged. Revision TKA was carried out in four patients, in whom knee joint flexion increased on average by 35 degrees to achieve an average flexion of 83 degrees. Restricted motion after TKA has been reported to range from 1.3 % to 12.0 %, but consistent criteria have not been set up. In our study it was 4.14 %. In agreement with the literature data, one of the reasons was pre-operative restricted motion, which was recorded in 16 of 32 patients. Similarly, also in our patients, biological predisposition to excessive production of fibrocartilage associated with adhesions in all knee joint compartments was the major therapeutic problem. Intra-operative fractures, ligament tears requiring post-operative fixation and unremoved dorsal osteophytes lead to the restriction of knee joint motion. By inadequate resection of articular surface, the original joint line may be at a higher level; this results in an increased tension of the posterior cruciate ligament and patella infera development, both influencing knee flexion. In our study, three patients were affected. Knee joint stiffness can also develop in patients declining physical therapy or in whom this is not correctly performed, often for insufficient analgesia. In contrast to the data reported in the literature, 17 of 32 patients in this study had no need for surgical treatment of restricted knee joint motion. Redress under general anesthesia was not effective. For markedly restricted motion of the knee joint, reimplantation can be recommended or, in less severe cases, an intervention on adjacent soft tissues. Restricted motion of the knee joint after TKA is difficult to treat and, therefore, prevention is recommended. This should include thorough conservative treatment of gonarthrosis, early indication for surgery, prevention of elevation in the joint line and consistent rehabilitation with appropriate analgesia. For severe stiffness of the knee joint, as evaluated by the criteria of Kim et al., revision arthroplasty can be recommended.

  5. Identification of a parametric, discrete-time model of ankle stiffness.

    PubMed

    Guarin, Diego L; Jalaleddini, Kian; Kearney, Robert E

    2013-01-01

    Dynamic ankle joint stiffness defines the relationship between the position of the ankle and the torque acting about it and can be separated into intrinsic and reflex components. Under stationary conditions, intrinsic stiffness can described by a linear second order system while reflex stiffness is described by Hammerstein system whose input is delayed velocity. Given that reflex and intrinsic torque cannot be measured separately, there has been much interest in the development of system identification techniques to separate them analytically. To date, most methods have been nonparametric and as a result there is no direct link between the estimated parameters and those of the stiffness model. This paper presents a novel algorithm for identification of a discrete-time model of ankle stiffness. Through simulations we show that the algorithm gives unbiased results even in the presence of large, non-white noise. Application of the method to experimental data demonstrates that it produces results consistent with previous findings.

  6. Prevention of the Post-traumatic Fibrotic Response in Joints

    DTIC Science & Technology

    2014-10-01

    an experimental model in mice. The American journal of forensic medicine and pathology . 1988; 9(4):310-2. 14 APPENDICES: An abstract...ongoing study addresses the critical clinical problem of posttraumatic joint stiffness, a pathology that reduces the range of motion (ROM) of injured...joints and contributes to the development of osteoarthritis. The fundamental hypothesis that drives the current study is that pathological fibrotic

  7. Estimation of Quasi-Stiffness of the Human Hip in the Stance Phase of Walking

    PubMed Central

    Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.

    2013-01-01

    This work presents a framework for selection of subject-specific quasi-stiffness of hip orthoses and exoskeletons, and other devices that are intended to emulate the biological performance of this joint during walking. The hip joint exhibits linear moment-angular excursion behavior in both the extension and flexion stages of the resilient loading-unloading phase that consists of terminal stance and initial swing phases. Here, we establish statistical models that can closely estimate the slope of linear fits to the moment-angle graph of the hip in this phase, termed as the quasi-stiffness of the hip. Employing an inverse dynamics analysis, we identify a series of parameters that can capture the nearly linear hip quasi-stiffnesses in the resilient loading phase. We then employ regression analysis on experimental moment-angle data of 216 gait trials across 26 human adults walking over a wide range of gait speeds (0.75–2.63 m/s) to obtain a set of general-form statistical models that estimate the hip quasi-stiffnesses using body weight and height, gait speed, and hip excursion. We show that the general-form models can closely estimate the hip quasi-stiffness in the extension (R2 = 92%) and flexion portions (R2 = 89%) of the resilient loading phase of the gait. We further simplify the general-form models and present a set of stature-based models that can estimate the hip quasi-stiffness for the preferred gait speed using only body weight and height with an average error of 27% for the extension stage and 37% for the flexion stage. PMID:24349136

  8. Multiscale biomechanical responses of adapted bone-periodontal ligament-tooth fibrous joints

    PubMed Central

    Jang, Andrew T.; Merkle, Arno; Fahey, Kevin; Gansky, Stuart A.; Ho, Sunita P.

    2015-01-01

    Reduced functional loads cause adaptations in organs. In this study, temporal adaptations of bone-ligament-tooth fibrous joints to reduced functional loads were mapped using a holistic approach. Systematic studies were performed to evaluate organ-level and tissue-level adaptations in specimens harvested periodically from rats given powder food for 6 months (N = 60 over 8,12,16,20, and 24 weeks). Bone-periodontal ligament (PDL)-tooth fibrous joint adaptation was evaluated by comparing changes in joint stiffness with changes in functional space between the tooth and alveolar bony socket. Adaptations in tissues included mapping changes in the PDL and bone architecture as observed from collagen birefringence, bone hardness and volume fraction in rats fed soft foods (soft diet, SD) compared to those fed hard pellets as a routine diet (hard diet, HD). In situ biomechanical testing on harvested fibrous joints revealed increased stiffness in SD groups (SD:239-605 N/mm) (p<0.05) at 8 and 12 weeks. Increased joint stiffness in early development phase was due to decreased functional space (at 8wks change in functional space was −33 µm, at 12wks change in functional space was −30 µm) and shifts in tissue quality as highlighted by birefringence, architecture and hardness. These physical changes were not observed in joints that were well into function, that is, in rodents older than 12 weeks of age. Significant adaptations in older groups were highlighted by shifts in bone growth (bone volume fraction 24wks: Δ-0.06) and bone hardness (8wks: Δ−0.04 GPa, 16 wks: Δ−0.07 GPa, 24wks: Δ−0.06 GPa). The response rate (N/s) of joints to mechanical loads decreased in SD groups. Results from the study showed that joint adaptation depended on age. The initial form-related adaptation (observed change in functional space) can challenge strain-adaptive nature of tissues to meet functional demands with increasing age into adulthood. The coupled effect between functional space in the bone-PDLtooth complex and strain-adaptive nature of tissues is necessary to accommodate functional demands, and is temporally sensitive despite joint malfunction. From an applied science perspective, we propose that adaptations are registered as functional history in tissues and joints. PMID:26151121

  9. Effects of 8-week swimming training on carotid arterial stiffness and hemodynamics in young overweight adults.

    PubMed

    Yuan, Wen-Xue; Liu, Hai-Bin; Gao, Feng-Shan; Wang, Yan-Xia; Qin, Kai-Rong

    2016-12-28

    Exercise has been found to either reduce or increase arterial stiffness. Land-based exercise modalities have been documented as effective physical therapies to decrease arterial stiffness. However, these land-based exercise modalities may not be suitable for overweight individuals, in terms of risks of joint injury. The purpose of this study was to determine the effects of 8-week swimming training and 4-week detraining on carotid arterial stiffness and hemodynamics in young overweight adults. Twenty young male adults who were overweight were recruited and engaged in 8-week of swimming training and 4-week detraining. Five individuals withdrew due to lack of interest and failure to follow the training protocol. Body Fat Percentage (BFP) and carotid hemodynamic variables were measured on a resting day at the following intervals: baseline, 4 weeks, 8 weeks after swimming training and 4 weeks after detraining. A repeated analysis of variance (ANOVA) was used to assess the differences between baseline and each measurement. When significant differences were detected, Tukey's test for post hoc comparisons was used. Eight-week swimming training at moderate intensity decreased BFP, including the trunk and four extremities. Additionally, the BFP of the right and left lower extremities continued to decrease in these overweight adults 4 weeks after ceasing training. Carotid arterial stiffness decreased, while there were no significant changes in arterial diameters. Blood flow velocity, flow rate, maximal and mean wall shear stress increased, while systolic blood pressure and peripheral resistance decreased. No significant differences existed in minimal wall shear stress and oscillatory shear stress. Eight-week swimming training at moderate intensity exhibited beneficial effects on systolic blood pressure, arterial stiffness and blood supply to the brain in overweight adults. Moreover, maximal and mean wall shear stress increased after training. It is worth noting that these changes in hemodynamics did not last 4 weeks. Therefore, further studies are still warranted to clarify the underlying relationship between improvements in arterial stiffness and alterations in wall shear stress.

  10. Dynamics of quiet human stance: computer simulations of a triple inverted pendulum model.

    PubMed

    Günther, Michael; Wagner, Heiko

    2016-01-01

    For decades, the biomechanical description of quiet human stance has been dominated by the single inverted pendulum (SIP) paradigm. However, in the past few years, the SIP model family has been falsified as an explanatory approach. Double inverted pendulum models have recently proven to be inappropriate. Human topology with three major leg joints suggests in a natural way to examine triple inverted pendulum (TIP) models as an appropriate approach. In this study, we focused on formulating a TIP model that can synthesise stable balancing attractors based on minimalistic sensor information and actuation complexity. The simulated TIP oscillation amplitudes are realistic in vertical direction. Along with the horizontal ankle, knee and hip positions, though, all simulated joint angle amplitudes still exceed the measured ones about threefold. It is likely that they could be eventually brought down to the physiological range by using more sensor information. The TIP systems' eigenfrequency spectra come out as another major result. The eigenfrequencies spread across about 0.1 Hz...20 Hz. Our main result is that joint stiffnesses can be reduced even below statically required values by using an active hip torque balancing strategy. When reducing mono- and bi-articular stiffnesses further down to levels threatening dynamic stability, the spectra indicate a change from torus-like (stable) to strange (chaotic) attractors. Spectra of measured ground reaction forces appear to be strange-attractor-like. We would conclude that TIP models are a suitable starting point to examine more deeply the dynamic character of and the essential structural properties behind quiet human stance. Abbreviations and technical terms Inverted pendulum body exposed to gravity and pivoting in a joint around position of unstable equilibrium (operating point) SIP single inverted pendulum: one rigid body pivoting around fixation to the ground (external joint) DIP double inverted pendulum: two bodies; external and internal joint operate around instability TIP triple inverted pendulum: three bodies; external and both internal joints operate around instability QIP quadruple inverted pendulum: four bodies, foot replaces external joint; all three internal joints operate around instability Eigenfrequency characteristic frequency that a physical system is oscillating at when externally excited at a limited energy level DOF degree of freedom; in mechanics: linear displacement or angle or combination thereof Mono-articular stiffness: coefficient of proportionality between mechanical displacement of a DOF and restoring force/torque component in the respective DOF Bi-articular stiffness coefficient of proportionality between mechanical displacement of a DOF and restoring force/torque component in another DOF GRF ground reaction force HAT segment including head, arms and trunk COM centre of mass COP centre of pressure in the plane of the force platform surface.

  11. Knee joint passive stiffness and moment in sagittal and frontal planes markedly increase with compression.

    PubMed

    Marouane, H; Shirazi-Adl, A; Adouni, M

    2015-01-01

    Knee joints are subject to large compression forces in daily activities. Due to artefact moments and instability under large compression loads, biomechanical studies impose additional constraints to circumvent the compression position-dependency in response. To quantify the effect of compression on passive knee moment resistance and stiffness, two validated finite element models of the tibiofemoral (TF) joint, one refined with depth-dependent fibril-reinforced cartilage and the other less refined with homogeneous isotropic cartilage, are used. The unconstrained TF joint response in sagittal and frontal planes is investigated at different flexion angles (0°, 15°, 30° and 45°) up to 1800 N compression preloads. The compression is applied at a novel joint mechanical balance point (MBP) identified as a point at which the compression does not cause any coupled rotations in sagittal and frontal planes. The MBP of the unconstrained joint is located at the lateral plateau in small compressions and shifts medially towards the inter-compartmental area at larger compression forces. The compression force substantially increases the joint moment-bearing capacities and instantaneous angular rigidities in both frontal and sagittal planes. The varus-valgus laxities diminish with compression preloads despite concomitant substantial reductions in collateral ligament forces. While the angular rigidity would enhance the joint stability, the augmented passive moment resistance under compression preloads plays a role in supporting external moments and should as such be considered in the knee joint musculoskeletal models.

  12. Relationships between habitual physical activity and osteoarthrosis in ageing women.

    PubMed

    White, J A; Wright, V; Hudson, A M

    1993-11-01

    The examination of middle-aged women specialist teachers of physical education, who have undertaken habitual physical activity over many years, demonstrated a lower prevalence of osteoarthrosis in the knee joints, a greater prevalence of degenerative joint disease in the lumbar spine and a similar prevalence of osteoarthrosis in the hips, compared with a closely age-matched group. A further review 12 years later revealed significantly less joint pain and joint stiffness in active women compared with less active controls.

  13. Serum matrix metalloproteinase 3 in detecting remitting seronegative symmetrical synovitis with pitting edema syndrome: A case report.

    PubMed

    Kenzaka, Tsuneaki; Goda, Ken

    2018-05-16

    We report a case of remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome in a 71-year-old woman. She referred to our hospital with finger stiffness, edema of both hands and feet, pain of bilateral shoulder, wrist, metacarpophalangeal, proximal interphalangeal, and ankle joints. Rheumatoid factor was negative, human leukocyte antigen -B7 antigen was positive. Moreover, matrix metalloproteinase 3 (MMP-3) was high. She was diagnosed with RS3PE syndrome, and treatment with prednisolone (15 mg/d) was started. One week after prednisolone treatment initiation, CRP decreased to negative, and joint pain was almost completely resolved. However, hand stiffness persisted, and MMP-3 level was still high. Thus, prednisolone dose was increased to 20 mg/d, and the stiffness resolved. Twenty days after treatment initiation, MMP-3 was normalized. MMP-3 was more indicative of RS3PE syndrome symptoms than CRP. Thus, MMP-3 seems to be more sensitive to RS3PE syndrome symptoms.

  14. Serum matrix metalloproteinase 3 in detecting remitting seronegative symmetrical synovitis with pitting edema syndrome: A case report

    PubMed Central

    Kenzaka, Tsuneaki; Goda, Ken

    2018-01-01

    We report a case of remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome in a 71-year-old woman. She referred to our hospital with finger stiffness, edema of both hands and feet, pain of bilateral shoulder, wrist, metacarpophalangeal, proximal interphalangeal, and ankle joints. Rheumatoid factor was negative, human leukocyte antigen -B7 antigen was positive. Moreover, matrix metalloproteinase 3 (MMP-3) was high. She was diagnosed with RS3PE syndrome, and treatment with prednisolone (15 mg/d) was started. One week after prednisolone treatment initiation, CRP decreased to negative, and joint pain was almost completely resolved. However, hand stiffness persisted, and MMP-3 level was still high. Thus, prednisolone dose was increased to 20 mg/d, and the stiffness resolved. Twenty days after treatment initiation, MMP-3 was normalized. MMP-3 was more indicative of RS3PE syndrome symptoms than CRP. Thus, MMP-3 seems to be more sensitive to RS3PE syndrome symptoms. PMID:29774220

  15. Prevention of the Post-traumatic Fibrotic Response in Joints

    DTIC Science & Technology

    2014-10-01

    JJ, Wolman M. Aging of wound healing in an experimental model in mice. The American journal of forensic medicine and pathology . 1988; 9(4):310-2...SUPPLEMENTARY NOTES 14. ABSTRACT The ongoing study addresses the critical clinical problem of posttraumatic joint stiffness, a pathology that reduces...study is that pathological fibrotic response of injured joint tissues may be limited by targeting the formation of collagen fibrils, a main component

  16. Fundamental Principles of Tremor Propagation in the Upper Limb.

    PubMed

    Davidson, Andrew D; Charles, Steven K

    2017-04-01

    Although tremor is the most common movement disorder, there exist few effective tremor-suppressing devices, in part because the characteristics of tremor throughout the upper limb are unknown. To clarify, optimally suppressing tremor requires a knowledge of the mechanical origin, propagation, and distribution of tremor throughout the upper limb. Here we present the first systematic investigation of how tremor propagates between the shoulder, elbow, forearm, and wrist. We simulated tremor propagation using a linear, time-invariant, lumped-parameter model relating joint torques and the resulting joint displacements. The model focused on the seven main degrees of freedom from the shoulder to the wrist and included coupled joint inertia, damping, and stiffness. We deliberately implemented a simple model to focus first on the most basic effects. Simulating tremorogenic joint torque as a sinusoidal input, we used the model to establish fundamental principles describing how input parameters (torque location and frequency) and joint impedance (inertia, damping, and stiffness) affect tremor propagation. We expect that the methods and principles presented here will serve as the groundwork for future refining studies to understand the origin, propagation, and distribution of tremor throughout the upper limb in order to enable the future development of optimal tremor-suppressing devices.

  17. Fundamental Principles of Tremor Propagation in the Upper Limb

    PubMed Central

    Davidson, Andrew D.; Charles, Steven K.

    2017-01-01

    Although tremor is the most common movement disorder, there exist few effective tremor-suppressing devices, in part because the characteristics of tremor throughout the upper limb are unknown. To clarify, optimally suppressing tremor requires a knowledge of the mechanical origin, propagation, and distribution of tremor throughout the upper limb. Here we present the first systematic investigation of how tremor propagates between the shoulder, elbow, forearm, and wrist. We simulated tremor propagation using a linear, time-invariant, lumped-parameter model relating joint torques and the resulting joint displacements. The model focused on the seven main degrees of freedom from the shoulder to the wrist and included coupled joint inertia, damping, and stiffness. We deliberately implemented a simple model to focus first on the most basic effects. Simulating tremorogenic joint torque as a sinusoidal input, we used the model to establish fundamental principles describing how input parameters (torque location and frequency) and joint impedance (inertia, damping, and stiffness) affect tremor propagation. We expect that the methods and principles presented here will serve as the groundwork for future refining studies to understand the origin, propagation, and distribution of tremor throughout the upper limb in order to enable the future development of optimal tremor-suppressing devices. PMID:27957608

  18. The effects of range-of-motion therapy on the plantar pressures of patients with diabetes mellitus.

    PubMed

    Goldsmith, Jon R; Lidtke, Roy H; Shott, Susan

    2002-10-01

    A randomized controlled study of 19 patients with diabetes mellitus (10 men, 9 women) was undertaken to determine the effects of home exercise therapy on joint mobility and plantar pressures. Of the 19 subjects, 9 subjects performed unsupervised active and passive range-of-motion exercises of the joints in their feet. Each subject was evaluated for joint stiffness and peak plantar pressures at the beginning and conclusion of the study. After only 1 month of therapy, a statistically significant average decrease of 4.2% in peak plantar pressures was noted in the subjects performing the range-of-motion exercises. In the control group, an average increase of 4.4% in peak plantar pressures was noted. Although the joint mobility data revealed no statistically significant differences between the groups, there was a trend for a decrease in joint stiffness in the treatment group. The results of this study demonstrate that an unsupervised range-of-motion exercise program can reduce peak plantar pressures in the diabetic foot. Given that high plantar pressures have been linked to diabetic neuropathic ulceration, it may be possible to reduce the risk of such ulceration with this therapy.

  19. A new mathematical neck model for a low-velocity rear-end impact dummy: evaluation of components influencing head kinematics.

    PubMed

    Linder, A

    2000-03-01

    A mathematical model of a new rear-end impact dummy neck was implemented using MADYMO. The main goal was to design a model with a human-like response of the first extension motion in the crash event. The new dummy neck was modelled as a series of rigid bodies (representing the seven cervical vertebrae and the uppermost thoracic element, T1) connected by pin joints, and supplemented by two muscle substitutes. The joints had non-linear stiffness characteristics and the muscle elements possessed both elastic stiffness and damping properties. The new model was compared with two neck models with the same number of vertebrae, but without muscle substitutes. The properties of the muscle substitutes and the need of these were evaluated by using three different modified neck models. The motion of T1 in the simulations was prescribed using displacement data obtained from volunteer tests. In a sensitivity analysis of the mathematical model the influence of different factors on the head-neck kinematics was evaluated. The neck model was validated against kinematics data from volunteer tests: linear displacement, angular displacement, and acceleration of the head relative to the upper torso at 7 km/h velocity change. The response of the new model was within the corridor of the volunteer tests for the main part of the time history plot. This study showed that a combination of elastic stiffness and damping in the muscle substitutes, together with a non-linear joint stiffness, resulted in a head-neck response similar to human volunteers, and superior to that of other tested neck models.

  20. The immediate effects of two manual therapy techniques on ankle musculoarticular stiffness and dorsiflexion range of motion in people with chronic ankle rigidity: A randomized clinical trial.

    PubMed

    Hidalgo, Benjamin; Hall, Toby; Berwart, Mathilde; Biernaux, Elinor; Detrembleur, Christine

    2017-12-29

    Ankle rigidity is a common musculoskeletal disorder affecting the talocrural joint, which can impair weight-bearing ankle dorsiflexion (WBADF) and daily-life in people with or without history of ankle injuries. Our objective was to compare the immediate effects of efficacy of Mulligan Mobilization with Movement (MWM) and Osteopathic Mobilization (OM) for improving ankle dorsiflexion range of motion (ROM) and musculoarticular stiffness (MAS) in people with chronic ankle dorsiflexion rigidity. A randomized clinical trial with two arms. Patients were recruited by word of mouth and via social network as well as posters, and analyzed in the neuro musculoskeletal laboratory of the "Université Catholique de Louvain-la-Neuve", Brussels, Belgium. 67 men (aged 18-40 years) presenting with potential chronic non-specific and unilateral ankle mobility deficit during WBDF were assessed for eligibility and finally 40 men were included and randomly allocated to single session of either MWM or OM. Two modalities of manual therapy indicated for hypothetic immediate effects in chronic ankle dorsiflexion stiffness, i.e. MWM and OM, were applied during a single session on included patients. Comprised blinding measures of MAS with a specific electromechanical device (namely: Lehmann's device) producing passive oscillatory ankle joint dorsiflexion and with clinical measures of WBADF-ROM as well. A two-way ANOVA revealed a non-significant interaction between both techniques and time for all outcome measures. For measures of MAS: elastic-stiffness (p= 0.37), viscous-stiffness (p= 0.83), total-stiffness (p= 0.58). For WBADF-ROM: toe-wall distance (p= 0.58) and angular ROM (p= 0.68). Small effect sizes between groups were determined with Cohen's d ranging from 0.05 to 0.29. One-way ANOVA demonstrated non-significant difference and small to moderate effects sizes (d= 0.003-0.58) on all outcome measures before and after interventions within both groups. A second two-way ANOVA analyzed the effect of each intervention on the sample categorized according to injury history status, and demonstrated a significant interaction between groups and time only for viscous stiffness (p= 0.04, d=-0.55). A single session of MWM and OM targeting the talocrural joint failed to immediately improve all measures in.

  1. Research on damping properties optimization of variable-stiffness plate

    NASA Astrophysics Data System (ADS)

    Wen-kai, QI; Xian-tao, YIN; Cheng, SHEN

    2016-09-01

    This paper investigates damping optimization design of variable-stiffness composite laminated plate, which means fibre paths can be continuously curved and fibre angles are distinct for different regions. First, damping prediction model is developed based on modal dissipative energy principle and verified by comparing with modal testing results. Then, instead of fibre angles, the element stiffness and damping matrixes are translated to be design variables on the basis of novel Discrete Material Optimization (DMO) formulation, thus reducing the computation time greatly. Finally, the modal damping capacity of arbitrary order is optimized using MMA (Method of Moving Asymptotes) method. Meanwhile, mode tracking technique is employed to investigate the variation of modal shape. The convergent performance of interpolation function, first order specific damping capacity (SDC) optimization results and variation of modal shape in different penalty factor are discussed. The results show that the damping properties of the variable-stiffness plate can be increased by 50%-70% after optimization.

  2. Reliability of metatarsophalangeal and ankle joint torque measurements by an innovative device.

    PubMed

    Man, Hok-Sum; Leung, Aaron Kam-Lun; Cheung, Jason Tak-Man; Sterzing, Thorsten

    2016-07-01

    The toe flexor muscles maintain body balance during standing and provide push-off force during walking, running, and jumping. Additionally, they are important contributing structures to maintain normal foot function. Thus, weakness of these muscles may cause poor balance, inefficient locomotion and foot deformities. The quantification of metatarsophalangeal joint (MPJ) stiffness is valuable as it is considered as a confounding factor in toe flexor muscles function. MPJ and ankle joint stiffness measurement is still largely depended on manual skills as current devices do not have good control on alignment, angular joint speed and displacement during measurement. Therefore, this study introduces an innovative dynamometer and protocol procedures for MPJ and ankle Joint torque measurement with precise and reliable foot alignment, angular joint speed and displacement control. Within-day and between-day test-retest experiments on MPJ and ankle joint torque measurement were conducted on ten and nine healthy male subjects respectively. The mean peak torques of MPJ and ankle joint of between-day and within-day measurement were 1.50±0.38Nm/deg and 1.19±0.34Nm/deg. The corresponding torques of the ankle joint were 8.24±2.20Nm/deg and 7.90±3.18Nm/deg respectively. Intraclass-correlation coefficients (ICC) of averaged peak torque of both joints of between-day and within-day test-retest experiments were ranging from 0.91 to 0.96, indicating the innovative device is systematic and reliable for the measurements and can be used for multiple scientific and clinical purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Case Report: The casting motion to mobilize stiffness technique for rehabilitation after a crush and degloving injury of the hand.

    PubMed

    Midgley, Robyn

    2016-01-01

    Case report. This case report describes the use of the casting motion to mobilize stiffness (CMMS) technique in the management of a crush and degloving injury of the hand. The patient was unable to attend multiple hand therapy sessions due to geographic constraints. The CMMS technique involved the application of a nonremovable plaster of paris cast that selectively immobilizes proximal joints in an ideal position while constraining distal joints to direct desired motion over a long period. This uses active motion only. Traditional hand therapy techniques or modalities are not used. This treatment approach was beneficial to the patient as a minimum of 2 appointments per month were needed to regain functional hand use. To document the use of the CMMS technique as an effective treatment approach in the management of a crush and degloving injury of the hand. The CMMS technique was applied to the patient's left (nondominant) hand 8 weeks after injury. The technique's aim was to improve the 30° flexion deformity of the left wrist and flexion contractures of the index, middle, and ring fingers with a total active motion of 0°. Orthotic devices and traditional therapy were applied once joint stiffness was resolved, and a normal pattern of motion was reinstated. At 6 months, substantial improvement was noted in wrist as well as metacarpophalangeal and interphalangeal joints. Total active motion exceeded 170° in all fingers excellent functional outcome resulted as measured with the upper limb functional index short form-10. The upper limb functional index increased from 0% to 55% of preinjury status (or capacity) over the 18 months of therapy. Brief immobilization through casting causes certain functional losses, but these are temporary and reversible. Finger stiffness, edema, and tissue fibrosis were successfully managed with the CMMS technique without the need for attendance at multiple hand therapy sessions. Level V. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Analytical Time-Domain Solution of Plane Wave Propagation Across a Viscoelastic Rock Joint

    NASA Astrophysics Data System (ADS)

    Zou, Yang; Li, Jianchun; Laloui, Lyesse; Zhao, Jian

    2017-10-01

    The effects of viscoelastic filled rock joints on wave propagation are of great significance in rock engineering. The solutions in time domain for plane longitudinal ( P-) and transverse ( S-) waves propagation across a viscoelastic rock joint are derived based on Maxwell and Kelvin models which are, respectively, applied to describe the viscoelastic deformational behaviour of the rock joint and incorporated into the displacement discontinuity model (DDM). The proposed solutions are verified by comparing with the previous studies on harmonic waves, which are simulated by sinusoidal incident P- and S-waves. Comparison between the predicted transmitted waves and the experimental data for P-wave propagation across a joint filled with clay is conducted. The Maxwell is found to be more appropriate to describe the filled joint. The parametric studies show that wave propagation is affected by many factors, such as the stiffness and the viscosity of joints, the incident angle and the duration of incident waves. Furthermore, the dependences of the transmission and reflection coefficients on the specific joint stiffness and viscosity are different for the joints with Maxwell and Kelvin behaviours. The alternation of the reflected and transmitted waveforms is discussed, and the application scope of this study is demonstrated by an illustration of the effects of the joint thickness. The solutions are also extended for multiple parallel joints with the virtual wave source method and the time-domain recursive method. For an incident wave with arbitrary waveform, it is convenient to adopt the present approach to directly calculate wave propagation across a viscoelastic rock joint without additional mathematical methods such as the Fourier and inverse Fourier transforms.

  5. A linear stepping endovascular intervention robot with variable stiffness and force sensing.

    PubMed

    He, Chengbin; Wang, Shuxin; Zuo, Siyang

    2018-05-01

    Robotic-assisted endovascular intervention surgery has attracted significant attention and interest in recent years. However, limited designs have focused on the variable stiffness mechanism of the catheter shaft. Flexible catheter needs to be partially switched to a rigid state that can hold its shape against external force to achieve a stable and effective insertion procedure. Furthermore, driving catheter in a similar way with manual procedures has the potential to make full use of the extensive experience from conventional catheter navigation. Besides driving method, force sensing is another significant factor for endovascular intervention. This paper presents a variable stiffness catheterization system that can provide stable and accurate endovascular intervention procedure with a linear stepping mechanism that has a similar operation mode to the conventional catheter navigation. A specially designed shape-memory polymer tube with water cooling structure is used to achieve variable stiffness of the catheter. Hence, four FBG sensors are attached to the catheter tip in order to monitor the tip contact force situation with temperature compensation. Experimental results show that the actuation unit is able to deliver linear and rotational motions. We have shown the feasibility of FBG force sensing to reduce the effect of temperature and detect the tip contact force. The designed catheter can change its stiffness partially, and the stiffness of the catheter can be remarkably increased in rigid state. Hence, in the rigid state, the catheter can hold its shape against a [Formula: see text] load. The prototype has also been validated with a vascular phantom, demonstrating the potential clinical value of the system. The proposed system provides important insights into the design of compact robotic-assisted catheter incorporating effective variable stiffness mechanism and real-time force sensing for intraoperative endovascular intervention.

  6. Total knee replacement with tibial tubercle osteotomy in rheumatoid patients with stiff knee.

    PubMed

    Eid, Ahmed Salem; Nassar, Wael Ahmed Mohamed; Fayyad, Tamer Abdelmeguid Mohamed

    2016-11-01

    Total knee arthroplasty (TKA) is a well-proven modality that can provide pain relief and restore mobility for rheumatoid arthritis (RA) patients with advanced joint destruction. Patellar ligament avulsion, especially in presence of poor bone quality and knee stiffness, is one of the special considerations that must be addressed in this unique population of patients. This study aimed to determine the functional results in a series of rheumatoid patients with stiff knee and end-stage joint destruction who underwent tibial tubercle osteotomy during TKA. Twenty-three knees in 20 patients (16 women; four men) at a mean age of 54 years with end-stage arthritis and knee stiffness due to RA were operated upon for TKA using tibial tubercle osteotomy as a step during the operation. Patients were reviewed clinically and radiographically with a minimum follow-up of two years. Complications were noted. Hospital for Special Surgery (HSS) score was recorded pre-operatively and at six and 12 months postoperatively. Union occurred at the osteotomy site in 21 of 23 cases. One case had deep venous thrombosis (DVT). There was no infection or periprosthetic fracture, and at last follow-up, no patient required revision. HSS score improved from 46 (15-60) pre-operatively to 85 (71-96) post-operatively. Tibial tubercle osteotomy during TKA in patients with RA and stiff knee is technically demanding yet proved to be effective in improving post-operative range of movement and minimising the complication of patellar ligament avulsion.

  7. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    NASA Technical Reports Server (NTRS)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  8. Quantifying Effects of Voids in Woven Ceramic Matrix Composites

    NASA Technical Reports Server (NTRS)

    Goldsmith, Marlana B.; Sankar, Bhavani V.; Haftka, Raphael T.; Goldberg, Robert K.

    2013-01-01

    Randomness in woven ceramic matrix composite architecture has been found to cause large variability in stiffness and strength. The inherent voids are an aspect of the architecture that may cause a significant portion of the variability. A study is undertaken to investigate the effects of many voids of random sizes and distributions. Response surface approximations were formulated based on void parameters such as area and length fractions to provide an estimate of the effective stiffness. Obtaining quantitative relationships between the properties of the voids and their effects on stiffness of ceramic matrix composites are of ultimate interest, but the exploratory study presented here starts by first modeling the effects of voids on an isotropic material. Several cases with varying void parameters were modeled which resulted in a large amount of variability of the transverse stiffness and out-of-plane shear stiffness. An investigation into a physical explanation for the stiffness degradation led to the observation that the voids need to be treated as an entity that reduces load bearing capabilities in a space larger than what the void directly occupies through a corrected length fraction or area fraction. This provides explanation as to why void volume fraction is not the only important factor to consider when computing loss of stiffness.

  9. Relationships between acoustic variables and different measures of stiffness in standing Pinus taeda trees

    Treesearch

    Christian R. Mora; Laurence R. Schimleck; Fikret Isik; Jerry M. Mahon Jr.; Alexander Clark III; Richard F. Daniels

    2009-01-01

    Acoustic tools are increasingly used to estimate standing-tree (dynamic) stiffness; however, such techniques overestimate static stiffness, the standard measurement for determining modulus of elasticity (MOE) of wood. This study aimed to identify correction methods for standing-tree estimates making dynamic and static stiffness comparable. Sixty Pinus taeda L...

  10. Four Weeks of Balance Training does not Affect Ankle Joint Stiffness in Subjects with Unilateral Chronic Ankle Instability

    PubMed Central

    Jain, Tarang Kumar; Wauneka, Clayton N.; Liu, Wen

    2016-01-01

    Background Balance training has been shown to be effective in preventing ankle sprain recurrences in subjects with chronic ankle instability (CAI) but the biomechanical pathways underlying the clinical outcomes are still unknown. This study was conducted to determine if a 4-week balance training intervention can alter the mechanical characteristics in ankles with CAI. Methods Twenty-two recreationally active subjects with unilateral CAI were randomized to either a control (n = 11, 35.1 ± 9.3 years) or intervention (n = 11, 33.5 ± 6.6 years) group. Subjects in the intervention group were trained on the affected limb with static and dynamic components using a Biodex balance stability system for 4-weeks. The ankle joint stiffness and neutral zone in inversion and eversion directions on the involved and uninvolved limbs was measured at baseline and post-intervention using a dynamometer. Results At baseline, the mean values of the inversion stiffness (0.69 ± 0.37 Nm/degree) in the involved ankle was significantly lower (p < 0.011, 95% CI [0.563, 0.544]) than that of uninvolved contralateral ankle (0.99 ± 0.41 Nm/degree). With the available sample size, the eversion stiffness, inversion neutral zone, and eversion neutral zone were not found to be significantly different between the involved and uninvolved contralateral ankles. The 4-week balance training intervention failed to show any significant effect on the passive ankle stiffness and neutral zones in inversion and eversion. Conclusion Decreased inversion stiffness in the involved chronic unstable ankle was found that of uninvolved contralateral ankle. The 4-week balance training program intervention was ineffective in altering the mechanical characteristics of ankles with CAI. Level of evidence Randomized controlled clinical trial; Level of evidence, 1. PMID:27642647

  11. In vivo biomechanical measurement and haptic simulation of portal placement procedure in shoulder arthroscopic surgery

    PubMed Central

    Chae, Sanghoon; Jung, Sung-Weon

    2018-01-01

    A survey of 67 experienced orthopedic surgeons indicated that precise portal placement was the most important skill in arthroscopic surgery. However, none of the currently available virtual reality simulators include simulation / training in portal placement, including haptic feedback of the necessary puncture force. This study aimed to: (1) measure the in vivo force and stiffness during a portal placement procedure in an actual operating room and (2) implement active haptic simulation of a portal placement procedure using the measured in vivo data. We measured the force required for port placement and the stiffness of the joint capsule during portal placement procedures performed by an experienced arthroscopic surgeon. Based on the acquired mechanical property values, we developed a cable-driven active haptic simulator designed to train the portal placement skill and evaluated the validity of the simulated haptics. Ten patients diagnosed with rotator cuff tears were enrolled in this experiment. The maximum peak force and joint capsule stiffness during posterior portal placement procedures were 66.46 (±10.76N) and 2560.82(±252.92) N/m, respectively. We then designed an active haptic simulator using the acquired data. Our cable-driven mechanism structure had a friction force of 3.763 ± 0.341 N, less than 6% of the mean puncture force. Simulator performance was evaluated by comparing the target stiffness and force with the stiffness and force reproduced by the device. R-squared values were 0.998 for puncture force replication and 0.902 for stiffness replication, indicating that the in vivo data can be used to implement a realistic haptic simulator. PMID:29494691

  12. Passive stiffness of coupled wrist and forearm rotations.

    PubMed

    Drake, Will B; Charles, Steven K

    2014-09-01

    Coordinated movement requires that the neuromuscular system account and compensate for movement dynamics. One particularly complex aspect of movement dynamics is the interaction that occurs between degrees of freedom (DOF), which may be caused by inertia, damping, and/or stiffness. During wrist rotations, the two DOF of the wrist (flexion-extension and radial-ulnar deviation, FE and RUD) are coupled through interaction torques arising from passive joint stiffness. One important unanswered question is whether the DOF of the forearm (pronation-supination, PS) is coupled to the two DOF of the wrist. Answering this question, and understanding the dynamics of wrist and forearm rotations in general, requires knowledge of the stiffness encountered during rotations involving all three DOF (PS, FE, and RUD). Here we present the first-ever measurement of the passive stiffness encountered during simultaneous wrist and forearm rotations. Using a wrist and forearm robot, we measured coupled wrist and forearm stiffness in 10 subjects and present it as a 3-by-3 stiffness matrix. This measurement of passive wrist and forearm stiffness will enable future studies investigating the dynamics of wrist and forearm rotations, exposing the dynamics for which the neuromuscular system must plan and compensate during movements involving the wrist and forearm.

  13. The effect of short-term isometric training on core/torso stiffness.

    PubMed

    Lee, Benjamin; McGill, Stuart

    2017-09-01

    "Core" exercise is a basic part of many physical training regimens with goals ranging from rehabilitation of spine and knee injuries to improving athletic performance. Core stiffness has been proposed to perform several functions including reducing pain by minimising joint micro-movements, and enhancing strength and speed performance. This study probes the links between a training approach and immediate but temporary changes in stiffness. Passive and active stiffness was measured on 24 participants; 12 having little to no experience in core training (inexperienced), and the other 12 being athletes experienced to core training methods; before and after a 15 min bout of isometric core exercises. Passive stiffness was assessed on a "frictionless" bending apparatus and active stiffness assessed via a quick release mechanism. Short-term isometric core training increased passive and active stiffness in most directions for both inexperienced and experienced participants, passive left lateral bend among experienced participants being the exception (P < 0.05). There was no difference between the inexperienced and experienced groups. The results confirm that the specific isometric training exercise approach tested here can induce immediate changes in core stiffness, in this case following a single session. This may influence performance and injury resilience for a brief period.

  14. Pulsed radiofrequency of the composite nerve supply to the knee joint as a new technique for relieving osteoarthritic pain: a preliminary report.

    PubMed

    Vas, Lakshmi; Pai, Renuka; Khandagale, Nishigandha; Pattnaik, Manorama

    2014-01-01

    We report a new technique for pulsed radiofrequency (PRF) of the entire nerve supply of the knee as an option in treating osteoarthritis (OA) of knee. We targeted both sensory and motor nerves supplying all the structures around the knee: joint, muscles, and skin to address the entire nociception and stiffness leading to peripheral and central sensitization in osteoarthritis. Ten patients with pain, stiffness, and loss of function in both knees were treated with ultrasonography (USG) guided PRF of saphenous, tibial, and common peroneal nerves along with subsartorial, peripatellar, and popliteal plexuses. USG guided PRF of the femoral nerve was also done to address the innervation of the quadriceps muscle. Assessment of pain (Numerical Rating Scale [NRS], pain DETECT, knee function [Western Ontario and McMaster Universities Osteoarthritis Index- WOMAC]) were documented pre and post PRF at 3 and 6 months. Knee radiographs (Kellgren-Lawrence [K-L] grading) were done before PRF and one week later. All the patients showed a sustained improvement of NRS, pain DETECT, and WOMAC at 3 and 6 months. The significant improvement of patellar position and tibio-femoral joint space was concordant with the patient's reporting of improvement in stiffness and pain. The sustained pain relief and muscle relaxation enabled the patients to optimize physiotherapy thereby improving endurance training to include the daily activities of life. We conclude that OA knee pain is a product of neuromyopathy and that PRF of the sensory and motor nerves appeared to be a safe, effective, and minimally invasive technique. The reduction of pain and stiffness improved the knee function and probably reduced the peripheral and central sensitization.

  15. Dynamic Analyses Including Joints Of Truss Structures

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith

    1991-01-01

    Method for mathematically modeling joints to assess influences of joints on dynamic response of truss structures developed in study. Only structures with low-frequency oscillations considered; only Coulomb friction and viscous damping included in analysis. Focus of effort to obtain finite-element mathematical models of joints exhibiting load-vs.-deflection behavior similar to measured load-vs.-deflection behavior of real joints. Experiments performed to determine stiffness and damping nonlinearities typical of joint hardware. Algorithm for computing coefficients of analytical joint models based on test data developed to enable study of linear and nonlinear effects of joints on global structural response. Besides intended application to large space structures, applications in nonaerospace community include ground-based antennas and earthquake-resistant steel-framed buildings.

  16. Effect of Treat-to-target Strategies Aiming at Remission of Arterial Stiffness in Early Rheumatoid Arthritis: A Randomized Controlled Study.

    PubMed

    Tam, Lydia Ho-Pui; Shang, Qing; Li, Edmund Kwok-Ming; Wong, Priscilla Ching-Han; Kwok, Kitty Yan; Kun, Emily Wai-Lin; Yim, Isaac Cheuk-Wan; Lee, Violet Ka-Lai; Yip, Ronald Man-Lung; Pang, Steve Hin-Ting; Lao, Virginia Weng-Nga; Mak, Queenie Wah-Yan; Cheng, Isaac Tsz-Ho; Lau, Xerox Sze-Lok; Li, Tena Ka-Yan; Zhu, Tracy Yaner; Lee, Alex Pui-Wai; Tam, Lai-Shan

    2018-05-15

    To determine the efficacy of 2 tight control treatment strategies aiming at Simplified Disease Activity Score (SDAI) remission (SDAI ≤ 3.3) compared to 28-joint count Disease Activity Score (DAS28) remission (DAS28 < 2.6) in the prevention of arterial stiffness in patients with early rheumatoid arthritis (RA). This was an open-label study in which 120 patients with early RA were randomized to receive 1 year of tight control treatment. Group 1 (n = 60) aimed to achieve SDAI ≤ 3.3 and Group 2 (n = 60), DAS28 < 2.6. Pulse wave velocity (PWV) and augmentation index (AIx) were measured at baseline and 12 months. A posthoc analysis was also performed to ascertain whether achieving sustained remission could prevent progression in arterial stiffness. The proportions of patients receiving methotrexate monotherapy were significantly lower in Group 1 throughout the study period. At 12 months, the proportions of patients achieving DAS28 and SDAI remission, and the change in PWV and AIx, were comparable between the 2 groups. In view of the lack of differences between the 2 groups, a posthoc analysis was performed at Month 12, including all 110 patients with PWV, to elucidate the independent predictors associated with the change in PWV. Multivariate analysis revealed that achieving sustained DAS28 remission at months 6, 9, and 12 and a shorter disease duration were independent explanatory variables associated with less progression of PWV. With limited access to biologic disease-modifying antirheumatic drugs, treatment efforts toward DAS28 and SDAI remission had similar effects in preventing the progression of arterial stiffness at 1 year. However, achieving sustained DAS28 remission was associated with a significantly greater improvement in PWV. [Clinical Trial registration: Clinicaltrial.gov NCT01768923.].

  17. The effect of postoperative passive motion on rotator cuff healing in a rat model.

    PubMed

    Peltz, Cathryn D; Dourte, Leann M; Kuntz, Andrew F; Sarver, Joseph J; Kim, Soung-Yon; Williams, Gerald R; Soslowsky, Louis J

    2009-10-01

    Surgical repairs of torn rotator cuff tendons frequently fail. Immobilization has been shown to improve tissue mechanical properties in an animal model of rotator cuff repair, and passive motion has been shown to improve joint mechanics in animal models of flexor tendon repair. Our objective was to determine if daily passive motion would improve joint mechanics in comparison with continuous immobilization in a rat rotator cuff repair model. We hypothesized that daily passive motion would result in improved passive shoulder joint mechanics in comparison with continuous immobilization initially and that there would be no differences in passive joint mechanics or insertion site mechanical properties after four weeks of remobilization. A supraspinatus injury was created and was surgically repaired in sixty-five Sprague-Dawley rats. Rats were separated into three postoperative groups (continuous immobilization, passive motion protocol 1, and passive motion protocol 2) for two weeks before all underwent a remobilization protocol for four weeks. Serial measurements of passive shoulder mechanics (internal and external range of motion and joint stiffness) were made before surgery and at two and six weeks after surgery. After the animals were killed, collagen organization and mechanical properties of the tendon-to-bone insertion site were determined. Total range of motion for both passive motion groups (49% and 45% of the pre-injury values) was less than that for the continuous immobilization group (59% of the pre-injury value) at two weeks and remained significantly less following four weeks of remobilization exercise. Joint stiffness at two weeks was increased for both passive motion groups in comparison with the continuous immobilization group. At both two and six weeks after repair, internal range of motion was significantly decreased whereas external range of motion was not. There were no differences between the groups in terms of collagen organization or mechanical properties. In this model, immediate postoperative passive motion was found to be detrimental to passive shoulder mechanics. We speculate that passive motion results in increased scar formation in the subacromial space, thereby resulting in decreased range of motion and increased joint stiffness. Passive motion had no effect on collagen organization or tendon mechanical properties measured six weeks after surgery.

  18. Reducing vibration transfer from power plants by active methods

    NASA Astrophysics Data System (ADS)

    Kiryukhin, A. V.; Milman, O. O.; Ptakhin, A. V.

    2017-12-01

    The possibility of applying the methods of active damping of vibration and pressure pulsations for reducing their transfer from power plants into the environment, the seating, and the industrial premises are considered. The results of experimental works implemented by the authors on the active broadband damping of vibration and dynamic forces after shock-absorption up to 15 dB in the frequency band up to 150 Hz, of water pressure pulsations in the pipeline up to 20 dB in the frequency band up to 600 Hz, and of spatial low-frequency air noise indoors of a diesel generator at discrete frequency up to 20 dB are presented. It is shown that a reduction of vibration transfer through a vibration-isolating junction (expansion joints) of pipelines with liquid is the most complicated and has hardly been developed so far. This problem is essential for vibration isolation of power equipment from the seating and the environment through pipelines with water and steam in the power and transport engineering, shipbuilding, and in oil and gas pipelines in pumping stations. For improving efficiency, reducing the energy consumption, and decreasing the overall dimensions of equipment, it is advisable to combine the work of an active system with passive damping means, the use of which is not always sufficient. The executive component of the systems of active damping should be placed behind the vibration isolators (expansion joints). It is shown that the existence of working medium and connection of vibration with pressure pulsations in existing designs of pipeline expansion joints lead to growth of vibration stiffness of the expansion joint with the environment by two and more orders as compared with the static stiffness and makes difficulties for using the active methods. For active damping of vibration transfer through expansion joints of pipelines with a liquid, it is necessary to develop expansion joint structures with minimal connection of vibrations and pulsations and minimal vibration stiffness in the specified frequency range. The example of structure of such expansion joint and its test results are presented.

  19. Effect of joint mechanism on vehicle redirectional capability of water-filled road safety barrier systems.

    PubMed

    Thiyahuddin, M I; Thambiratnam, D P; Gu, Y T

    2014-10-01

    Portable water-filled barriers (PWFBs) are roadside appurtenances that prevent vehicles from penetrating into temporary construction zones on roadways. PWFBs are required to satisfy the strict regulations for vehicle re-direction in tests. However, many of the current PWFBs fail to re-direct the vehicle at high speeds due to the inability of the joints to provide appropriate stiffness. The joint mechanism hence plays a crucial role in the performance of a PWFB system at high speed impacts. This paper investigates the desired features of the joint mechanism in a PWFB system that can re-direct vehicles at high speeds, while limiting the lateral displacement to acceptable limits. A rectangular "wall" representative of a 30m long barrier system was modeled and a novel method of joining adjacent road barriers was introduced through appropriate pin-joint connections. The impact response of the barrier "wall" and the vehicle was obtained and the results show that a rotational stiffness of 3000kNm/rad at the joints seems to provide the desired features of the PWFB system to re-direct impacting vehicles and restrict the lateral deflection. These research findings will be useful to safety engineers and road barrier designers in developing a new generation of PWFBs for increased road safety. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Resonant Column Tests and Nonlinear Elasticity in Simulated Rocks

    NASA Astrophysics Data System (ADS)

    Sebastian, Resmi; Sitharam, T. G.

    2018-01-01

    Rocks are generally regarded as linearly elastic even though the manifestations of nonlinearity are prominent. The variations of elastic constants with varying strain levels and stress conditions, disagreement between static and dynamic moduli, etc., are some of the examples of nonlinear elasticity in rocks. The grain-to-grain contact, presence of pores and joints along with other compliant features induce the nonlinear behavior in rocks. The nonlinear elastic behavior of rocks is demonstrated through resonant column tests and numerical simulations in this paper. Resonant column tests on intact and jointed gypsum samples across varying strain levels have been performed in laboratory and using numerical simulations. The paper shows the application of resonant column apparatus to obtain the wave velocities of stiff samples at various strain levels under long wavelength condition, after performing checks and incorporating corrections to the obtained resonant frequencies. The numerical simulation and validation of the resonant column tests using distinct element method are presented. The stiffness reductions of testing samples under torsional and flexural vibrations with increasing strain levels have been analyzed. The nonlinear elastic behavior of rocks is reflected in the results, which is enhanced by the presence of joints. The significance of joint orientation and influence of joint spacing during wave propagation have also been assessed and presented using the numerical simulations. It has been found that rock joints also exhibit nonlinear behavior within the elastic limit.

  1. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    PubMed Central

    Höppner, Hannes; Große-Dunker, Maximilian; Stillfried, Georg; Bayer, Justin; van der Smagt, Patrick

    2017-01-01

    We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands. PMID:28588472

  2. An Analytical Model for Two-Order Asperity Degradation of Rock Joints Under Constant Normal Stiffness Conditions

    NASA Astrophysics Data System (ADS)

    Li, Yingchun; Wu, Wei; Li, Bo

    2018-05-01

    Jointed rock masses during underground excavation are commonly located under the constant normal stiffness (CNS) condition. This paper presents an analytical formulation to predict the shear behaviour of rough rock joints under the CNS condition. The dilatancy and deterioration of two-order asperities are quantified by considering the variation of normal stress. We separately consider the dilation angles of waviness and unevenness, which decrease to zero as the normal stress approaches the transitional stress. The sinusoidal function naturally yields the decay of dilation angle as a function of relative normal stress. We assume that the magnitude of transitional stress is proportionate to the square root of asperity geometric area. The comparison between the analytical prediction and experimental data shows the reliability of the analytical model. All the parameters involved in the analytical model possess explicit physical meanings and are measurable from laboratory tests. The proposed model is potentially practicable for assessing the stability of underground structures at various field scales.

  3. The Load Distribution in Bolted or Riveted Joints in Light-Alloy Structures

    NASA Technical Reports Server (NTRS)

    Vogt, F.

    1947-01-01

    This report contains a theoretical discussion of the load distribution in bolted or riveted joints in light-alloy structures which is applicable not only for loads below the limit of proportionality but also for loads above this limit. The theory is developed for double and single shear joints. The methods given are illustrated by numerical examples and the values assumed for the bolt (or rivet) stiffnesses are based partly on theory and partly on known experimental values. It is shown that the load distribution does not vary greatly with the bolt (or rivet) stiffnesses and that for design purposes it is usually sufficient to know their order of magnitude. The theory may also be directly used for spot-welded structures and, with small modifications, for seam-welded structures, The computational work involved in the methods described is simple and may be completed in a reasonable time for most practical problems. A summary of earlier theoretical and experimental investigations on the subject is included in the report.

  4. Time-dependent behavior of rough discontinuities under shearing conditions

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Shen, Mingrong; Ding, Wenqi; Jang, Boan; Zhang, Qingzhao

    2018-02-01

    The mechanical properties of rocks are generally controlled by their discontinuities. In this study, the time-dependent behavior of rough artificial joints under shearing conditions was investigated. Based on Barton’s standard profile lines, samples with artificial joint surfaces were prepared and used to conduct the shear and creep tests. The test results showed that the shear strength of discontinuity was linearly related to roughness, and subsequently an empirical equation was established. The long-term strength of discontinuity can be identified using the inflection point of the isocreep-rate curve, and it was linearly related to roughness. Furthermore, the ratio of long-term and instantaneous strength decreased with the increase of roughness. The shear-stiffness coefficient increased with the increase of shear rate, and the influence of shear rate on the shear stiffness coefficient decreased with the decrease of roughness. Further study of the mechanism revealed that these results could be attributed to the different time-dependent behavior of intact and joint rocks.

  5. Reconstruction of shifting elbow joint compliant characteristics during fast and slow movements.

    PubMed

    Latash, M L; Gottlieb, G L

    1991-01-01

    The purpose of this study was to experimentally investigate the applicability of the equilibrium-point hypothesis to the dynamics of single-joint movements. Subjects were trained to perform relatively slow (movement time 600-1000 ms) or fast (movement time 200-300 ms) single-joint elbow flexion movements against a constant extending torque bias. They were instructed to reproduce the same time pattern of central motor command for a series of movements when the external torque could slowly and unpredictably increase, decrease, or remain constant. For fast movements, the total muscle torque was calculated as a sum of external and inertial components. Analysis of the data allowed reconstruction of the elbow joint compliant characteristics at different times during execution of the learned motor command. "Virtual" trajectories of the movements, representing time-varying changes in a central control parameter, were reconstructed and compared with the "actual" trajectories. For slow movements, the actual trajectories lagged behind the virtual ones. There were no consistent changes in the joint stiffness during slow movements. Similar analysis of experiments without voluntary movements demonstrated a lack of changes in the central parameters, supporting the assumption that the subjects were able to keep the same central motor command in spite of externally imposed unexpected torque perturbations. For the fast movements, the virtual trajectories were N-shaped, and the joint stiffness demonstrated a considerable increase near the middle of the movement. These findings contradict an hypothesis of monotonic joint compliant characteristic translation at a nearly constant rate during such movements.

  6. Preliminary Assessment of a Compliant Gait Exoskeleton.

    PubMed

    Cestari, Manuel; Sanz-Merodio, Daniel; Garcia, Elena

    2017-06-01

    Current commercial wearable gait exoskeletons contain joints with stiff actuators that cannot adapt to unpredictable environments. These actuators consume a significant amount of energy, and their stiffness may not be appropriate for safe human-machine interactions. Adjustable compliant actuators are being designed and implemented because of their ability to minimize large forces due to shocks, to safely interact with the user, and to store and release energy in passive elastic elements. Introduction of such compliant actuation in gait exoskeletons, however, has been limited by the larger power-to-weight and volume ratio requirement. This article presents a preliminary assessment of the first compliant exoskeleton for children. Compliant actuation systems developed by our research group were integrated into the ATLAS exoskeleton prototype. The resulting device is a compliant exoskeleton, the ATLAS-C prototype. The exoskeleton is coupled with a special standing frame to provide balance while allowing a semi-natural gait. Experiments show that when comparing the behavior of the joints under different stiffness conditions, the inherent compliance of the implemented actuators showed natural adaptability during the gait cycle and in regions of shock absorption. Torque tracking of the joint is achieved, identifying the areas of loading response. The implementation of a state machine in the control of knee motion allowed reutilization of the stored energy during deflection at the end of the support phase to partially propel the leg and achieve a more natural and free swing.

  7. Flurbiprofen

    MedlinePlus

    Flurbiprofen is used to relieve pain, tenderness, swelling, and stiffness caused by osteoarthritis (arthritis caused by a ... by swelling of the lining of the joints). Flurbiprofen is in a class of medications called NSAIDs. ...

  8. Classical and numerical approaches to determining V-section band clamp axial stiffness

    NASA Astrophysics Data System (ADS)

    Barrans, Simon M.; Khodabakhshi, Goodarz; Muller, Matthias

    2015-01-01

    V-band clamp joints are used in a wide range of applications to connect circular flanges, for ducts, pipes and the turbocharger housing. Previous studies and research on V-bands are either purely empirical or analytical with limited applicability on the variety of V-band design and working conditions. In this paper models of the V-band are developed based on the classical theory of solid mechanics and the finite element method to study the behaviour of theV-bands under axial loading conditions. The good agreement between results from the developed FEA and the classical model support the suitability of the latter to modelV-band joints with diameters greater than 110mm under axial loading. The results from both models suggest that the axial stiffness for thisV-band cross section reaches a peak value for V-bands with radius of approximately 150 mmacross a wide range of coefficients of friction. Also, it is shown that the coefficient of friction and the wedge angle have a significant effect on the axial stiffness of V-bands.

  9. Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses.

    PubMed

    Adamczyk, Peter Gabriel; Roland, Michelle; Hahn, Michael E

    2017-08-01

    Many studies have reported the effects of different foot prostheses on gait, but most results cannot be generalized because the prostheses' properties are seldom reported. We varied hindfoot and forefoot stiffness in an experimental foot prosthesis, in increments of 15N/mm, and tested the parametric effects of these variations on treadmill walking in unilateral transtibial amputees, at speeds from 0.7 to 1.5m/s. We computed outcomes such as prosthesis energy return, center of mass (COM) mechanics, ground reaction forces, and joint mechanics, and computed their sensitivity to component stiffness. A stiffer hindfoot led to reduced prosthesis energy return, increased ground reaction force (GRF) loading rate, and greater stance-phase knee flexion and knee extensor moment. A stiffer forefoot resulted in reduced prosthetic-side ankle push-off and COM push-off work, and increased knee extension and knee flexor moment in late stance. The sensitivity parameters obtained from these tests may be useful in clinical prescription and further research into compensatory mechanisms of joint function. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Analysis and Modeling of Chromosome Congression During Mitosis in the Chemotherapy Drug Cisplatin.

    PubMed

    Chacón, Jeremy M; Gardner, Melissa K

    2013-12-01

    The chemotherapy drug Cisplatin (cis-diamminedichloroplatinum(II)) induces crosslinks within and between DNA strands, and between DNA and nearby proteins. Therefore, Cisplatin-treated cells which progress into cell division may do so with altered chromosome mechanical properties. This could have important consequences for the successful completion of mitosis. Using Total Internal Reflection Fluorescence (TIRF) microscopy of live Cisplatin-treated Saccharomyces cerevisiae cells, we found that metaphase mitotic spindles have disorganized kinetochores relative to untreated cells, and also that there is increased variability in the chromosome stretching distance between sister centromeres. This suggests that chromosome stiffness may become more variable after Cisplatin treatment. We explored the effect of variable chromosome stiffness during mitosis using a stochastic model in which kinetochore microtubule dynamics were regulated by tension imparted by stretched sister chromosomes. Consistent with experimental results, increased variability of chromosome stiffness in the model led to disorganization of kinetochores in simulated metaphase mitotic spindles. Furthermore, the variability in simulated chromosome stretching tension was increased as chromosome stiffness became more variable. Because proper chromosome stretching tension may serve as a signal that is required for proper progression through mitosis, tension variability could act to impair this signal and thus prevent proper mitotic progression. Our results suggest a possible mitotic mode of action for the anti-cancer drug Cisplatin.

  11. Can hybrid hyaluronic acid represent a valid approach to treat rizoarthrosis? A retrospective comparative study.

    PubMed

    Tenti, Sara; Pascarelli, Nicola Antonio; Giannotti, Stefano; Galeazzi, Mauro; Giordano, Nicola; Fioravanti, Antonella

    2017-11-13

    Osteoarthritis (OA) of the trapeziometacarpal joint (TMJ) is a disabling condition with a significant impact on quality of life. The optimal management of hand OA requires a combination of non-pharmacological and pharmacological treatments that include intra-articular (i.a.) therapy. EULAR experts recommend corticosteroid injections in TMJ OA and underline the usefulness of hyaluronic acid (HA). The aim of this study was the assessment of the efficacy and tolerability of i.a. injections of a hybrid formulation of HA (Sinovial H-L®) in comparison to triamcinolone in patients with TMJ OA. This 6-months observational comparative study, retrospective analyzed the medical records of 100 patients with monolateral or bilateral TMJ OA, treated with two injections of Sinovial H-L® (Sinovial H-L Group) or of triamcinolone acetonide (Triamcinolone Group). Clinical assessments were recorded at the time of the first and second injection and after one, 3 and 6 months. The primary outcomes were the change in global pain on a Visual Analogue Scale (VAS) and in hand function evaluated by the Functional Index for Hand OA (FIHOA) from baseline to month 6. Secondary outcomes were the improvement of the duration of morning stiffness, Health Assessment Questionnaire (HAQ) and the Medical Outcomes Study 36-Item Short Form (SF-36). The comparison between the two groups of treatment were performed with the Wilcoxon rank-sum test for continuous variables and with chi-square or Fisher exact test for categorical variables. Statistical significance was set at p < 0.05. Both therapies provided effective pain relief and joint function improvement, but the benefits achieved were statistically significantly superior in the Sinovial H-L Group than the Triamcinolone Group after one month (p < 0.01) from the beginning of the therapy and during the 6-months follow-up (p < 0.001). Furthermore, Sinovial H-L® was associated with a significant decrease in the duration of morning stiffness and with a significant improvement in the HAQ score and physical component summary (PCS)-SF-36. Our results suggested that the hybrid formulation of HA may be more effective than triamcinolone in pain relief and joint function improvement with a rapid and persistent effect, resulting a valid alternative to steroid in the management of TMJ OA. ClinicalTrials.gov, date of registration: June 14, 2017, NCT03200886 . The present trial was retrospectively registered.

  12. Evaluation of feedforward and feedback contributions to hand stiffness and variability in multijoint arm control.

    PubMed

    He, Xin; Du, Yu-Fan; Lan, Ning

    2013-07-01

    The purpose of this study is to validate a neuromechanical model of the virtual arm (VA) by comparing emerging behaviors of the model to those of experimental observations. Hand stiffness of the VA model was obtained by either theoretical computation or simulated perturbations. Variability in hand position of the VA was generated by adding signal dependent noise (SDN) to the motoneuron pools of muscles. Reflex circuits of Ia, Ib and Renshaw cells were included to regulate the motoneuron pool outputs. Evaluation of hand stiffness and variability was conducted in simulations with and without afferent feedback under different patterns of muscle activations during postural maintenance. The simulated hand stiffness and variability ellipses captured the experimentally observed features in shape, magnitude and orientation. Steady state afferent feedback contributed significantly to the increase in hand stiffness by 35.75±16.99% in area, 18.37±7.80% and 16.15±7.15% in major and minor axes; and to the reduction of hand variability by 49.41±21.19% in area, 36.89±12.78% and 18.87±23.32% in major and minor axes. The VA model reproduced the neuromechanical behaviors that were consistent with experimental data, and it could be a useful tool for study of neural control of posture and movement, as well as for application to rehabilitation.

  13. An easily implemented static condensation method for structural sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Gangadharan, S. N.; Haftka, R. T.; Nikolaidis, E.

    1990-01-01

    A black-box approach to static condensation for sensitivity analysis is presented with illustrative examples of a cube and a car structure. The sensitivity of the structural response with respect to joint stiffness parameter is calculated using the direct method, forward-difference, and central-difference schemes. The efficiency of the various methods for identifying joint stiffness parameters from measured static deflections of these structures is compared. The results indicate that the use of static condensation can reduce computation times significantly and the black-box approach is only slightly less efficient than the standard implementation of static condensation. The ease of implementation of the black-box approach recommends it for use with general-purpose finite element codes that do not have a built-in facility for static condensation.

  14. Investigation into discretization methods of the six-parameter Iwan model

    NASA Astrophysics Data System (ADS)

    Li, Yikun; Hao, Zhiming; Feng, Jiaquan; Zhang, Dingguo

    2017-02-01

    Iwan model is widely applied for the purpose of describing nonlinear mechanisms of jointed structures. In this paper, parameter identification procedures of the six-parameter Iwan model based on joint experiments with different preload techniques are performed. Four kinds of discretization methods deduced from stiffness equation of the six-parameter Iwan model are provided, which can be used to discretize the integral-form Iwan model into a sum of finite Jenkins elements. In finite element simulation, the influences of discretization methods and numbers of Jenkins elements on computing accuracy are discussed. Simulation results indicate that a higher accuracy can be obtained with larger numbers of Jenkins elements. It is also shown that compared with other three kinds of discretization methods, the geometric series discretization based on stiffness provides the highest computing accuracy.

  15. Effect of adhesive stiffness and thickness on stress distributions in structural finger joints

    Treesearch

    Leslie H. Groom; Robert J. Leichti

    1994-01-01

    Environmental, political. and socioeconomic actions over the past several years have resulted in a decreased wood supply at a time when there is an increased demand for forest products. This combination of increased demand and decreased supply has forced more emphasis on engineered wood products, a varied category usually connected with adhesively-bonded end joints, of...

  16. Effect of adhesive stiffness and thickness on stress distributions in structural finger joints

    Treesearch

    Leslie H. Groom; Robert J. Leichti

    1994-01-01

    Environmental, political, and socioeconomic actions over the past several years have resulted in a decreased wood supply at a time when there is an increased demand for forest products. This combination of increased demand and decreased supply has forced more emphasis on engineered wood products, a varied category usually connected with adhesively-bonded end joints, of...

  17. Estimation of tissue stiffness, reflex activity, optimal muscle length and slack length in stroke patients using an electromyography driven antagonistic wrist model.

    PubMed

    de Gooijer-van de Groep, Karin L; de Vlugt, Erwin; van der Krogt, Hanneke J; Helgadóttir, Áróra; Arendzen, J Hans; Meskers, Carel G M; de Groot, Jurriaan H

    2016-06-01

    About half of all chronic stroke patients experience loss of arm function coinciding with increased stiffness, reduced range of motion and a flexed wrist due to a change in neural and/or structural tissue properties. Quantitative assessment of these changes is of clinical importance, yet not trivial. The goal of this study was to quantify the neural and structural properties contributing to wrist joint stiffness and to compare these properties between healthy subjects and stroke patients. Stroke patients (n=32) and healthy volunteers (n=14) were measured using ramp-and-hold rotations applied to the wrist joint by a haptic manipulator. Neural (reflexive torque) and structural (connective tissue stiffness and slack lengths and (contractile) optimal muscle lengths) parameters were estimated using an electromyography driven antagonistic wrist model. Kruskal-Wallis analysis with multiple comparisons was used to compare results between healthy subjects, stroke patients with modified Ashworth score of zero and stroke patients with modified Ashworth score of one or more. Stroke patients with modified Ashworth score of one or more differed from healthy controls (P<0.05) by increased tissue stiffness, increased reflexive torque, decreased optimal muscle length and decreased slack length of connective tissue of the flexor muscles. Non-invasive quantitative analysis, including estimation of optimal muscle lengths, enables to identify neural and non-neural changes in chronic stroke patients. Monitoring these changes in time is important to understand the recovery process and to optimize treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Loading rate increases during barefoot running in habitually shod runners: Individual responses to an unfamiliar condition.

    PubMed

    Tam, Nicholas; Astephen Wilson, Janie L; Coetzee, Devon R; van Pletsen, Leanri; Tucker, Ross

    2016-05-01

    The purpose of this study was to examine the effect of barefoot running on initial loading rate (LR), lower extremity joint kinematics and kinetics, and neuromuscular control in habitually shod runners with an emphasis on the individual response to this unfamiliar condition. Kinematics and ground reaction force data were collected from 51 habitually shod runners during overground running in a barefoot and shod condition. Joint kinetics and stiffness were calculated with inverse dynamics. Inter-individual initial LR variability was explored by separating individuals by a barefoot/shod ratio to determine acute responders/non-responders. Mean initial LR was 54.1% greater in the barefoot when compared to the shod condition. Differences between acute responders/non-responders were found at peak and initial contact sagittal ankle angle and at initial ground contact. Correlations were found between barefoot sagittal ankle angle at initial ground contact and barefoot initial LR. A large variability in biomechanical responses to an acute exposure to barefoot running was found. A large intra-individual variability was found in initial LR but not ankle plantar-dorsiflexion between footwear conditions. A majority of habitually shod runners do not exhibit previously reported benefits in terms of reduced initial LRs when barefoot. Lastly, runners who increased LR when barefoot reduced LRs when wearing shoes to levels similar seen in habitually barefoot runners who do adopt a forefoot-landing pattern, despite increased dorsiflexion. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Analysis and Design of Variable Stiffness Composite Cylinders

    NASA Technical Reports Server (NTRS)

    Tatting, Brian F.; Guerdal, Zafer

    1998-01-01

    An investigation of the possible performance improvements of thin circular cylindrical shells through the use of the variable stiffness concept is presented. The variable stiffness concept implies that the stiffness parameters change spatially throughout the structure. This situation is achieved mainly through the use of curvilinear fibers within a fiber-reinforced composite laminate, though the possibility of thickness variations and discrete stiffening elements is also allowed. These three mechanisms are incorporated into the constitutive laws for thin shells through the use of Classical Lamination Theory. The existence of stiffness variation within the structure warrants a formulation of the static equilibrium equations from the most basic principles. The governing equations include sufficient detail to correctly model several types of nonlinearity, including the formation of a nonlinear shell boundary layer as well as the Brazier effect due to nonlinear bending of long cylinders. Stress analysis and initial buckling estimates are formulated for a general variable stiffness cylinder. Results and comparisons for several simplifications of these highly complex governing equations are presented so that the ensuing numerical solutions are considered reliable and efficient enough for in-depth optimization studies. Four distinct cases of loading and stiffness variation are chosen to investigate possible areas of improvement that the variable stiffness concept may offer over traditional constant stiffness and/or stiffened structures. The initial investigation deals with the simplest solution for cylindrical shells in which all quantities are constant around the circumference of the cylinder. This axisymmetric case includes a stiffness variation exclusively in the axial direction, and the only pertinent loading scenarios include constant loads of axial compression, pressure, and torsion. The results for these cases indicate that little improvement over traditional laminates exists through the use of curvilinear fibers, mainly due to the presence of a weak link area within the stiffness variation that limits the ultimate load that the structure can withstand. Rigorous optimization studies reveal that even though slight increases in the critical loads can be produced for designs with an arbitrary variation of the fiber orientation angle, the improvements are not significant when compared to traditional design techniques that utilize ring stiffeners and frames. The second problem that is studied involves arbitrary loading of a cylinder with a stiffness variation that changes only in the circumferential direction. The end effects of the cylinder are ignored, so that the problem takes the form of an analysis of a cross-section for a short cylinder segment. Various load cases including axial compression, pressure, torsion, bending, and transverse shear forces are investigated. It is found that the most significant improvements in load-carrying capability exist for cases which involve loads that also vary around the circumference of the shell, namely bending and shear forces. The stiffness variation of the optimal designs contribute to the increased performance in two ways: lowering the stresses in the critical areas through redistribution of the stresses; and providing a relatively stiff region that alters the buckling behavior of the structure. These results lead to an in-depth optimization study involving weight optimization of a fuselage structure subjected to typical design constraints. Comparisons of the curvilinear fiber format to traditional stiffened structures constructed of isotropic and composite materials are included. It is found that standard variable stiffness designs are quite comparable in terms of weight and load-carrying capability yet offer the added advantage of tailorability of distinct regions of the structure that experience drastically different loading conditions. The last two problems presented in this work involve the nonlinear phenomenon of long tubes under bending. Though this scenario is not as applicable to fuselage structures as the previous problems, the mechanisms that produce the nonlinear effect are ideally suited to be controlled by the variable stiffness concept. This is due to the fact that the dominating influence for long cylinders under bending is the ovalization of the cross-section, which is governed mainly by the stiffness parameters of the cylindrical shell. Possible improvement of the critical buckling moments for these structures is investigated using either a circumferential or axial stiffness variation. For the circumferential case involving infinite length cylinders, it is found that slight improvements can be observed by designing structures that resist the cross-sectional deformation yet do not detract from the buckling resistance at the critical location. The results also indicate that buckling behavior is extremely dependent on cylinder length. This effect is most easily seen in the solution of finite length cylinders under bending that contain an axial stiffness variation. For these structures, the only mechanism that exhibits improved response are those that effectively shorten the length of the cylinder, thus reducing the cross-sectional deformation due to the forced restraint at the ends. It was found that the use of curvilinear fibers was not able to achieve this effect in sufficient degree to resist the deformation, but that ring stiffeners produced the desired response admirably. Thus, it is shown that the variable stiffness concept is most effective at improving the bending response of long cylinders through the use of a circumferential stiffness variation.

  20. Etodolac

    MedlinePlus

    Etodolac tablets, capsules, and extended-release (long-acting) tablets are used to relieve pain, tenderness, swelling, and stiffness caused ... swelling of the lining of the joints). Etodolac tablets and capsules are also used to relieve pain ...

  1. Tolmetin

    MedlinePlus

    ... breakdown of the lining of the joints) and rheumatoid arthritis (arthritis caused by swelling of the lining of ... pain, tenderness, swelling, and stiffness caused by juvenile rheumatoid arthritis in children 2 years of age and older. ...

  2. Oxaprozin

    MedlinePlus

    ... breakdown of the lining of the joints) and rheumatoid arthritis (arthritis caused by swelling of the lining of ... pain, tenderness, swelling, and stiffness caused by juvenile rheumatoid arthritis in children 6 years of age and older. ...

  3. Meloxicam

    MedlinePlus

    ... breakdown of the lining of the joints) and rheumatoid arthritis (arthritis caused by swelling of the lining of ... pain, tenderness, swelling, and stiffness caused by juvenile rheumatoid arthritis (a type of arthritis that affects children) in ...

  4. Stiffness and Damping in Postural Control Increase with Age

    PubMed Central

    Cenciarini, Massimo; Loughlin, Patrick J.; Sparto, Patrick J.; Redfern, Mark S.

    2011-01-01

    Upright balance is believed to be maintained through active and passive mechanisms, both of which have been shown to be impacted by aging. A compensatory balance response often observed in older adults is increased co-contraction, which is generally assumed to enhance stability by increasing joint stiffness. We investigated the effect of aging on standing balance by fitting body sway data to a previously-developed postural control model that includes active and passive stiffness and damping parameters. Ten young (24 ± 3 y) and seven older (75 ± 5 y) adults were exposed during eyes-closed stance to perturbations consisting of lateral pseudorandom floor tilts. A least-squares fit of the measured body sway data to the postural control model found significantly larger active stiffness and damping model parameters in the older adults. These differences remained significant even after normalizing to account for different body sizes between the young and older adult groups. An age effect was also found for the normalized passive stiffness, but not for the normalized passive damping parameter. This concurrent increase in active stiffness and damping was shown to be more stabilizing than an increase in stiffness alone, as assessed by oscillations in the postural control model impulse response. PMID:19770083

  5. Nuclear Fuel Depletion Analysis Using Matlab Software

    NASA Astrophysics Data System (ADS)

    Faghihi, F.; Nematollahi, M. R.

    Coupled first order IVPs are frequently used in many parts of engineering and sciences. In this article, we presented a code including three computer programs which are joint with the Matlab software to solve and plot the solutions of the first order coupled stiff or non-stiff IVPs. Some engineering and scientific problems related to IVPs are given and fuel depletion (production of the 239Pu isotope) in a Pressurized Water Nuclear Reactor (PWR) are computed by the present code.

  6. Design and verification of a hybrid nonlinear MRE vibration absorber for controllable broadband performance

    NASA Astrophysics Data System (ADS)

    Sun, S. S.; Yildirim, T.; Wu, Jichu; Yang, J.; Du, H.; Zhang, S. W.; Li, W. H.

    2017-09-01

    In this work, a hybrid nonlinear magnetorheological elastomer (MRE) vibration absorber has been designed, theoretically investigated and experimentally verified. The proposed nonlinear MRE absorber has the dual advantages of a nonlinear force-displacement relationship and variable stiffness technology; the purpose for coupling these two technologies is to achieve a large broadband vibration absorber with controllable capability. To achieve a nonlinear stiffness in the device, two pairs of magnets move at a rotary angle against each other, and the theoretical nonlinear force-displacement relationship has been theoretically calculated. For the experimental investigation, the effects of base excitation, variable currents applied to the device (i.e. variable stiffness of the MRE) and semi-active control have been conducted to determine the enhanced broadband performance of the designed device. It was observed the device was able to change resonance frequency with the applied current; moreover, the hybrid nonlinear MRE absorber displayed a softening-type nonlinear response with clear discontinuous bifurcations observed. Furthermore, the performance of the device under a semi-active control algorithm displayed the optimal performance in attenuating the vibration from a primary system to the absorber over a large frequency bandwidth from 4 to 12 Hz. By coupling nonlinear stiffness attributes with variable stiffness MRE technology, the performance of a vibration absorber is substantially improved.

  7. Collar height and heel counter-stiffness for ankle stability and athletic performance in basketball.

    PubMed

    Liu, Hui; Wu, Zitian; Lam, Wing-Kai

    2017-01-01

    This study examined the effects of collar height and heel counter-stiffness of basketball shoes on ankle stability during sidestep cutting and athletic performance. 15 university basketball players wore customized shoes with different collar heights (high and low) and heel counter-stiffness (regular, stiffer and stiffest) for this study. Ankle stability was evaluated in sidestep cutting while athletic performance evaluated in jumping and agility tasks. All variables were analysed using two-way repeated ANOVA. Results showed shorter time to peak ankle inversion for both high collar and stiff heel counter conditions (P < 0.05), while smaller initial ankle inversion angle, peak inversion velocity and total range of inversion for wearing high collar shoes (P < 0.05). No shoe differences were found for performance variables. These findings imply that the collar height might play a larger role in lateral stability than heel counter-stiffness, while both collar height and counter-stiffness have no effect on athletic performance.

  8. Design, analysis, and testing of the Phase 1 CSI Evolutionary Model erectable truss

    NASA Technical Reports Server (NTRS)

    Gronet, M. J.; Davis, D. A.; Kintis, D. H.; Brillhart, R. D.; Atkins, E. M.

    1992-01-01

    This report addressed the design, analysis, and testing of the erectable truss structure for the Phase 1 CSI Evolutionary Model (CEM) testbed. The Phase 1 CEM testbed is the second testbed to form part of an ongoing program of focused research at NASA/LaRC in the development of Controls-Structures Integration (CSI) technology. The Phase 1 CEM contains the same overall geometry, weight, and sensor locations as the Phase 0 CEM, but is based in an integrated controller and structure design, whereby both structure and controller design variables are sized simultaneously. The Phase 1 CEM design features seven truss sections composed of struts with tailored mass and stiffness properties. A common erectable joint is used and the strut stiffness is tailored by varying the cross-sectional area. To characterize the structure, static tests were conducted on individual struts and 10-bay truss assemblies. Dynamic tests were conducted on 10-bay truss assemblies as well as the fully-assembled CEM truss. The results indicate that the static and dynamic properties of the structure are predictable, well-characterized, and within the performance requirements established during the Phase 1 CEM integrated controller/structure design analysis.

  9. Tissue-engineered collateral ligament composite allografts for scapholunate ligament reconstruction: an experimental study.

    PubMed

    Endress, Ryan; Woon, Colin Y L; Farnebo, Simon J; Behn, Anthony; Bronstein, Joel; Pham, Hung; Yan, Xinrui; Gambhir, Sanjiv S; Chang, James

    2012-08-01

    In patients with chronic scapholunate (SL) dissociation or dynamic instability, ligament repair is often not possible, and surgical reconstruction is indicated. The ideal graft ligament would recreate both anatomical and biomechanical properties of the dorsal scapholunate ligament (dorsal SLIL). The finger proximal interphalangeal joint (PIP joint) collateral ligament could possibly be a substitute ligament. We harvested human PIP joint collateral ligaments and SL ligaments from 15 cadaveric limbs. We recorded ligament length, width, and thickness, and measured the biomechanical properties (ultimate load, stiffness, and displacement to failure) of native dorsal SLIL, untreated collateral ligaments, decellularized collateral ligaments, and SL repairs with bone-collateral ligament-bone composite collateral ligament grafts. As proof of concept, we then reseeded decellularized bone-collateral ligament-bone composite grafts with green fluorescent protein-labeled adipo-derived mesenchymal stem cells and evaluated them histologically. There was no difference in ultimate load, stiffness, and displacement to failure among native dorsal SLIL, untreated and decellularized collateral ligaments, and SL repairs with tissue-engineered collateral ligament grafts. With pair-matched untreated and decellularized scaffolds, there was no difference in ultimate load or stiffness. However, decellularized ligaments revealed lower displacement to failure compared with untreated ligaments. There was no difference in displacement between decellularized ligaments and native dorsal SLIL. We successfully decellularized grafts with recently described techniques, and they could be similarly reseeded. Proximal interphalangeal joint collateral ligament-based bone-collateral ligament-bone composite allografts had biomechanical properties similar to those of native dorsal SLIL. Decellularization did not adversely affect material properties. These tissue-engineered grafts may offer surgeons another option for reconstruction of chronic SL instability. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Measuring multi-joint stiffness during single movements: numerical validation of a novel time-frequency approach.

    PubMed

    Piovesan, Davide; Pierobon, Alberto; DiZio, Paul; Lackner, James R

    2012-01-01

    This study presents and validates a Time-Frequency technique for measuring 2-dimensional multijoint arm stiffness throughout a single planar movement as well as during static posture. It is proposed as an alternative to current regressive methods which require numerous repetitions to obtain average stiffness on a small segment of the hand trajectory. The method is based on the analysis of the reassigned spectrogram of the arm's response to impulsive perturbations and can estimate arm stiffness on a trial-by-trial basis. Analytic and empirical methods are first derived and tested through modal analysis on synthetic data. The technique's accuracy and robustness are assessed by modeling the estimation of stiffness time profiles changing at different rates and affected by different noise levels. Our method obtains results comparable with two well-known regressive techniques. We also test how the technique can identify the viscoelastic component of non-linear and higher than second order systems with a non-parametrical approach. The technique proposed here is very impervious to noise and can be used easily for both postural and movement tasks. Estimations of stiffness profiles are possible with only one perturbation, making our method a useful tool for estimating limb stiffness during motor learning and adaptation tasks, and for understanding the modulation of stiffness in individuals with neurodegenerative diseases.

  11. Stiff muscle fibers in calf muscles of patients with cerebral palsy lead to high passive muscle stiffness.

    PubMed

    Mathewson, Margie A; Chambers, Henry G; Girard, Paul J; Tenenhaus, Mayer; Schwartz, Alexandra K; Lieber, Richard L

    2014-12-01

    Cerebral palsy (CP), caused by an injury to the developing brain, can lead to alterations in muscle function. Subsequently, increased muscle stiffness and decreased joint range of motion are often seen in patients with CP. We examined mechanical and biochemical properties of the gastrocnemius and soleus muscles, which are involved in equinus muscle contracture. Passive mechanical testing of single muscle fibers from gastrocnemius and soleus muscle of patients with CP undergoing surgery for equinus deformity showed a significant increase in fiber stiffness (p<0.01). Bundles of fibers that included their surrounding connective tissues showed no stiffness difference (p=0.28).). When in vivo sarcomere lengths were measured and fiber and bundle stiffness compared at these lengths, both fibers and bundles of patients with CP were predicted to be much stiffer in vivo compared to typically developing (TD) individuals. Interestingly, differences in fiber and bundle stiffness were not explained by typical biochemical measures such as titin molecular weight (a giant protein thought to impact fiber stiffness) or collagen content (a proxy for extracellular matrix amount). We suggest that the passive mechanical properties of fibers and bundles are thus poorly understood. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. The importance of assessment and management of morning stiffness in Asian patients with rheumatoid arthritis: Recommendations from an expert panel.

    PubMed

    Mok, Chi Chiu; Cha, Hoon Suk; Hidayat, Rudy; Nguyen, Lan Thi Ngoc; Perez, Emmanuel C; Ramachandran, Raveendran; Tsay, Gregory J; Yoo, Dae Hyun

    2016-01-01

    In patients with rheumatoid arthritis (RA), morning stiffness is linked more to functional disability and pain than disease activity, as assessed by joint counts and markers of inflammation. As part of the Asia Pacific Morning Stiffness in Rheumatoid Arthritis Expert Panel, a group of eight rheumatologists met to formulate consensus points and develop recommendations for the assessment and management of morning stiffness in RA. On the basis of a systematic literature review and expert opinion, a panel of Asian rheumatologists formulated recommendations for the assessment and medical treatment of RA. The panel agreed upon 10 consensus statements on morning stiffness, its assessment and treatment. Specifically, the panel recommended that morning stiffness, pain and impaired morning function should be routinely assessed in clinical practice. Although there are currently no validated tools for these parameters, they should be assessed as part of the patients' reported outcomes in RA. The panel also agreed on the benefits of low-dose glucocorticoids in RA, particularly for the improvement of morning stiffness. These recommendations serve to guide rheumatologists and other stakeholders on the assessment and management of morning stiffness, and help implement the treat-to-target principle in the management of RA. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  13. Pneumatic Variable Series Elastic Actuator.

    PubMed

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  14. Pneumatic Variable Series Elastic Actuator

    PubMed Central

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-01-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on–off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator. PMID:27354755

  15. Intrinsic ankle stiffness during standing increases with ankle torque and passive stretch of the Achilles tendon

    PubMed Central

    Gill, Jaspret

    2018-01-01

    Individuals may stand with a range of ankle angles. Furthermore, shoes or floor surfaces may elevate or depress their heels. Here we ask how these situations impact ankle stiffness and balance. We performed two studies (each with 10 participants) in which the triceps surae, Achilles tendon and aponeurosis were stretched either passively, by rotating the support surface, or actively by leaning forward. Participants stood freely on footplates which could rotate around the ankle joint axis. Brief, small stiffness-measuring perturbations (<0.7 deg; 140 ms) were applied at intervals of 4–5 s. In study 1, participants stood at selected angles of forward lean. In study 2, normal standing was compared with passive dorsiflexion induced by 15 deg toes-up tilt of the support surface. Smaller perturbations produced higher stiffness estimates, but for all perturbation sizes stiffness increased with active torque or passive stretch. Sway was minimally affected by stretch or lean, suggesting that this did not underlie the alterations in stiffness. In quiet stance, maximum ankle stiffness is limited by the tendon. As tendon strain increases, it becomes stiffer, causing an increase in overall ankle stiffness, which would explain the effects of leaning. However, stiffness also increased considerably with passive stretch, despite a modest torque increase. We discuss possible explanations for this increase. PMID:29558469

  16. Surgery Considerations for Adults and Children

    MedlinePlus

    ... may be posed by complicating factors such as dental problems (skeletal fragility makes dentitia prone to fracture), cleft palate, joint stiffness or heart valve disease. Anesthesia personnel also need to be aware of ...

  17. Internal rotor friction instability

    NASA Technical Reports Server (NTRS)

    Walton, J.; Artiles, A.; Lund, J.; Dill, J.; Zorzi, E.

    1990-01-01

    The analytical developments and experimental investigations performed in assessing the effect of internal friction on rotor systems dynamic performance are documented. Analytical component models for axial splines, Curvic splines, and interference fit joints commonly found in modern high speed turbomachinery were developed. Rotor systems operating above a bending critical speed were shown to exhibit unstable subsynchronous vibrations at the first natural frequency. The effect of speed, bearing stiffness, joint stiffness, external damping, torque, and coefficient of friction, was evaluated. Testing included material coefficient of friction evaluations, component joint quantity and form of damping determinations, and rotordynamic stability assessments. Under conditions similar to those in the SSME turbopumps, material interfaces experienced a coefficient of friction of approx. 0.2 for lubricated and 0.8 for unlubricated conditions. The damping observed in the component joints displayed nearly linear behavior with increasing amplitude. Thus, the measured damping, as a function of amplitude, is not represented by either linear or Coulomb friction damper models. Rotordynamic testing of an axial spline joint under 5000 in.-lb of static torque, demonstrated the presence of an extremely severe instability when the rotor was operated above its first flexible natural frequency. The presence of this instability was predicted by nonlinear rotordynamic time-transient analysis using the nonlinear component model developed under this program. Corresponding rotordynamic testing of a shaft with an interference fit joint demonstrated the presence of subsynchronous vibrations at the first natural frequency. While subsynchronous vibrations were observed, they were bounded and significantly lower in amplitude than the synchronous vibrations.

  18. Error Modeling and Experimental Study of a Flexible Joint 6-UPUR Parallel Six-Axis Force Sensor.

    PubMed

    Zhao, Yanzhi; Cao, Yachao; Zhang, Caifeng; Zhang, Dan; Zhang, Jie

    2017-09-29

    By combining a parallel mechanism with integrated flexible joints, a large measurement range and high accuracy sensor is realized. However, the main errors of the sensor involve not only assembly errors, but also deformation errors of its flexible leg. Based on a flexible joint 6-UPUR (a kind of mechanism configuration where U-universal joint, P-prismatic joint, R-revolute joint) parallel six-axis force sensor developed during the prephase, assembly and deformation error modeling and analysis of the resulting sensors with a large measurement range and high accuracy are made in this paper. First, an assembly error model is established based on the imaginary kinematic joint method and the Denavit-Hartenberg (D-H) method. Next, a stiffness model is built to solve the stiffness matrix. The deformation error model of the sensor is obtained. Then, the first order kinematic influence coefficient matrix when the synthetic error is taken into account is solved. Finally, measurement and calibration experiments of the sensor composed of the hardware and software system are performed. Forced deformation of the force-measuring platform is detected by using laser interferometry and analyzed to verify the correctness of the synthetic error model. In addition, the first order kinematic influence coefficient matrix in actual circumstances is calculated. By comparing the condition numbers and square norms of the coefficient matrices, the conclusion is drawn theoretically that it is very important to take into account the synthetic error for design stage of the sensor and helpful to improve performance of the sensor in order to meet needs of actual working environments.

  19. Error Modeling and Experimental Study of a Flexible Joint 6-UPUR Parallel Six-Axis Force Sensor

    PubMed Central

    Zhao, Yanzhi; Cao, Yachao; Zhang, Caifeng; Zhang, Dan; Zhang, Jie

    2017-01-01

    By combining a parallel mechanism with integrated flexible joints, a large measurement range and high accuracy sensor is realized. However, the main errors of the sensor involve not only assembly errors, but also deformation errors of its flexible leg. Based on a flexible joint 6-UPUR (a kind of mechanism configuration where U-universal joint, P-prismatic joint, R-revolute joint) parallel six-axis force sensor developed during the prephase, assembly and deformation error modeling and analysis of the resulting sensors with a large measurement range and high accuracy are made in this paper. First, an assembly error model is established based on the imaginary kinematic joint method and the Denavit-Hartenberg (D-H) method. Next, a stiffness model is built to solve the stiffness matrix. The deformation error model of the sensor is obtained. Then, the first order kinematic influence coefficient matrix when the synthetic error is taken into account is solved. Finally, measurement and calibration experiments of the sensor composed of the hardware and software system are performed. Forced deformation of the force-measuring platform is detected by using laser interferometry and analyzed to verify the correctness of the synthetic error model. In addition, the first order kinematic influence coefficient matrix in actual circumstances is calculated. By comparing the condition numbers and square norms of the coefficient matrices, the conclusion is drawn theoretically that it is very important to take into account the synthetic error for design stage of the sensor and helpful to improve performance of the sensor in order to meet needs of actual working environments. PMID:28961209

  20. Prevention of the Post traumatic Fibrotic Response in Joints

    DTIC Science & Technology

    2016-12-01

    researchers focusing on research associated with post -traumatic joint stiffness. This team has grown from a group of three initial Principal Investigators...The formation of the Translational Research Partnership ensured reaching the stated objective. Two Specific Aims were defined to test the...body weight of rabbits during the initial 8 weeks of the experimental study. During this time the rabbits were treated with tested and control

  1. Patellofemoral Arthroplasty: Current Concepts and Review of the Literature

    PubMed Central

    Pisanu, Gabriele; Rosso, Federica; Bertolo, Corrado; Dettoni, Federico; Blonna, Davide; Bonasia, Davide Edoardo; Rossi, Roberto

    2017-01-01

    Patellofemoral osteoarthritis (PFOA) can be associated with anterior knee pain, stiffness, and functional impairment. Some authors report that PFOA affects approximately 9% of patients older than 40 years with a greater prevalence in females. Etiology of PFOA is multifactorial and is related to the presence of abnormal stresses at the PF joint due to knee- and patient-related factors. The need for a joint preserving treatment by isolated replacement of the injured compartment of the knee led to the development of PF arthroplasty (PFA). When a correct PF replacement is performed, PFA preserves physiologic tibiofemoral joint, thus allowing patients for a rapid recovery with a high satisfaction. The outcomes for PFA are quite variable with a trend toward good to excellent results, mainly owing to the improvement in surgical techniques, patient selection, and implant design. The development of the second generation of PFA improved the outcomes, which is attributed to the different trochlear designs. Recently, encouraging results have been provided by the association of PFA and unicompartmental knee arthroplasty (UKA). In many studies, the main cause of PFA failure is progression of tibiofemoral OA. The aim of this brief review of literature is to summarize the clinical features, indications and contraindications, surgical techniques, complications, and outcomes of PFA. PMID:29270562

  2. Active stiffness and strength in people with unilateral anterior shoulder instability: a bilateral comparison.

    PubMed

    Olds, Margie; McNair, Peter; Nordez, Antoine; Cornu, Christophe

    2011-01-01

    Active muscle stiffness might protect the unstable shoulder from recurrent dislocation. To compare strength and active stiffness in participants with unilateral anterior shoulder instability and to examine the relationship between active stiffness and functional ability. Cross-sectional study. University research laboratory. Participants included 16 males (age range, 16-40 years; height = 179.4 ± 6.1 cm; mass = 79.1 ± 6.8 kg) with 2 or more episodes of unilateral traumatic anterior shoulder instability. Active stiffness and maximal voluntary strength were measured bilaterally in participants. In addition, quality of life, function, and perceived instability were measured using the Western Ontario Stability Index, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, and Single Alpha Numeric Evaluation, respectively. We found less horizontal adduction strength (t(15) = -4.092, P = .001) and less stiffness at 30% (t(14) = -3.796, P = .002) and 50% (t(12) = -2.341, P = .04) maximal voluntary strength in the unstable than stable shoulder. Active stiffness was not correlated with quality of life, function, or perceived instability (r range, 0.0-0.25; P > .05). The observed reduction in stiffness in the unstable shoulder warrants inclusion of exercises in the rehabilitation program to protect the joint from perturbations that might lead to dislocation. The lack of association between active stiffness and quality of life, function, or perceived instability might indicate that stiffness plays a less direct role in shoulder stability.

  3. How joint characteristics between a piezoelectric beam and the main structure affect the performance of an energy harvester

    NASA Astrophysics Data System (ADS)

    Jahani, K.; Rafiei, M. M.; Aghazadeh, P.

    2017-09-01

    In this paper, the influence of the joint region between a piezoelectric energy harvesting beam and the vibratory main structure is studied. The investigations are conducted in two separate sections, namely numerical and experimental studies. In numerical studies, the effects of nonlinear parameters on generated power are investigated while the joint characteristics the between vibrating base and a piezoelectric energy harvester are taken into consideration. A unimorph beam with a tip mass and a nonlinear piezoelectric layer that undergoes a large-amplitude deflection is considered as an energy harvester. By applying the Euler-Lagrange equation and Gauss’s law the mechanical and electrical equations of motion are obtained, respectively. The excitation frequency is assumed to be close to the first natural frequency. Thus, a unimodal response is considered to be like that of a system with a single degree of freedom (SDOF). The joint between the vibrating main structure and the cantilevered beam is then added to the SDOF model. The joint characteristics are simulated with a light mass, mj , linear spring stiffness, kj , and equivalent viscous damper, cj . In two scenarios, i.e. with a rigid joint and with a flexible one, a numerical approach is followed to investigate the effects of each nonlinear parameter of the harvester (stiffness, damping and piezoelectric coefficient) on the harvested power. In experimental studies, the influence of a bolted joining technique and a flexible adhesive bonding method on the harvested power is investigated. The results achieved experimentally confirm those obtained numerically, i.e. a stiffer joint leads to a greater power produced by the harvester. In other words, neglecting the joint characteristics will cause the performance (maximum output power and the range of excitation frequency) of the harvester to be overestimated in numerical simulations.

  4. Contribution of facet joints, axial compression, and composition to human lumbar disc torsion mechanics.

    PubMed

    Bezci, Semih E; Eleswarapu, Ananth; Klineberg, Eric O; O'Connell, Grace D

    2018-02-12

    Stresses applied to the spinal column are distributed between the intervertebral disc and facet joints. Structural and compositional changes alter stress distributions within the disc and between the disc and facet joints. These changes influence the mechanical properties of the disc joint, including its stiffness, range of motion, and energy absorption under quasi-static and dynamic loads. There have been few studies evaluating the role of facet joints in torsion. Furthermore, the relationship between biochemical composition and torsion mechanics is not well understood. Therefore, the first objective of this study was to investigate the role of facet joints in torsion mechanics of healthy and degenerated human lumbar discs under a wide range of compressive preloads. To achieve this, each disc was tested under four different compressive preloads (300-1200 N) with and without facet joints. The second objective was to develop a quantitative structure-function relationship between tissue composition and torsion mechanics. Facet joints have a significant contribution to disc torsional stiffness (∼60%) and viscoelasticity, regardless of the magnitude of axial compression. The findings from this study demonstrate that annulus fibrosus GAG content plays an important role in disc torsion mechanics. A decrease in GAG content with degeneration reduced torsion mechanics by more than an order of magnitude, while collagen content did not significantly influence disc torsion mechanics. The biochemical-mechanical and compression-torsion relationships reported in this study allow for better comparison between studies that use discs of varying levels of degeneration or testing protocols and provide important design criteria for biological repair strategies. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Novel compliant actuator for wearable robotics applications.

    PubMed

    Claros, M; Soto, R; Rodríguez, J J; Cantú, C; Contreras-Vidal, José L

    2013-01-01

    In the growing fields of wearable robotics, rehabilitation robotics, prosthetics, and walking robots, variable impedance and force actuators are being designed and implemented because of their ability to dynamically modulate the intrinsic viscoelastic properties such as stiffness and damping. This modulation is crucial to achieve an efficient and safe human-robot interaction that could lead to electronically generate useful emergent dynamical behaviors. In this work we propose a novel actuation system in which is implemented a control scheme based on equilibrium forces for an active joint capable to provide assistance/resistance as needed and also achieve minimal mechanical impedance when tracking the movement of the user limbs. The actuation system comprises a DC motor with a built in speed reducer, two force-sensing resistors (FSR), a mechanism which transmits to the FSRs the torque developed in the joint and a controller which regulate the amount of energy that is delivered to the DC motor. The proposed system showed more impedance reduction, by the effect of the controlled contact forces, compared with the ones in the reviewed literature.

  6. Analysis of polyethylene terephthalate PET plastic bottle jointing system using finite element method (FEM)

    NASA Astrophysics Data System (ADS)

    Zaidi, N. A.; Rosli, Muhamad Farizuan; Effendi, M. S. M.; Abdullah, Mohamad Hariri

    2017-09-01

    For almost all injection molding applications of Polyethylene Terephthalate (PET) plastic was analyzed the strength, durability and stiffness of properties by using Finite Element Method (FEM) for jointing system of wood furniture. The FEM was utilized for analyzing the PET jointing system for Oak and Pine as wood based material of furniture. The difference pattern design of PET as wood jointing furniture gives the difference value of strength furniture itself. The results show the wood specimen with grooves and eclipse pattern design PET jointing give lower global estimated error is 28.90%, compare to the rectangular and non-grooves wood specimen of global estimated error is 63.21%.

  7. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    PubMed

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  8. Can We Predict Those With Osteoarthritis Who Will Worsen Following a Chronic Disease Management Program?

    PubMed

    Eyles, Jillian P; Mills, Kathryn; Lucas, Barbara R; Williams, Matthew J; Makovey, Joanna; Teoh, Laurence; Hunter, David J

    2016-09-01

    To identify predictors of worsening symptoms and overall health of the treated hip or knee joint following 26 weeks of a nonsurgical chronic disease management program for hip and knee osteoarthritis (OA) and to examine the consistency of these predictors across 3 definitions of worsening. This prospective cohort study followed 539 participants of the program for 26 weeks. The 3 definitions of worsening included symptomatic worsening based on change in the Western Ontario and McMaster Universities Osteoarthritis Index Global score (WOMAC-G) measuring pain, stiffness, and function; a transition scale that asked about overall health of the treated hip or knee joint; and a composite outcome including both. Multivariate logistic regression models were constructed for the 3 definitions of worsening. Complete data were available for 386 participants: mean age was 66.3 years, 69% were female, 85% reported knee joint pain as primary symptom (signal joint), 46% were waitlisted for total joint arthroplasty (TJA). TJA waitlist status, signal joint, 6-Minute Walk Test (6MWT), depressive symptoms, pain, and age were independently associated with at least 1 definition of worsening. TJA waitlist status and 6MWT remained in the multivariate models for the transition and composite definitions of worsening. Participants reporting worsening on the transition scale did not consistently meet the WOMAC-G definition of worsening symptoms. TJA waitlist status was predictive of the composite definition of worsening, a trend apparent for the transition definition. However, variables that predict worsening remain largely unknown. Further research is required to direct comprehensive and targeted management of patients with hip and knee OA. © 2016, American College of Rheumatology.

  9. Quantitative evaluations of ankle spasticity and stiffness in neurological disorders using manual spasticity evaluator.

    PubMed

    Peng, Qiyu; Park, Hyung-Soon; Shah, Parag; Wilson, Nicole; Ren, Yupeng; Wu, Yi-Ning; Liu, Jie; Gaebler-Spira, Deborah J; Zhang, Li-Qun

    2011-01-01

    Spasticity and contracture are major sources of disability in people with neurological impairments that have been evaluated using various instruments: the Modified Ashworth Scale, tendon reflex scale, pendulum test, mechanical perturbations, and passive joint range of motion (ROM). These measures generally are either convenient to use in clinics but not quantitative or they are quantitative but difficult to use conveniently in clinics. We have developed a manual spasticity evaluator (MSE) to evaluate spasticity/contracture quantitatively and conveniently, with ankle ROM and stiffness measured at a controlled low velocity and joint resistance and Tardieu catch angle measured at several higher velocities. We found that the Tardieu catch angle was linearly related to the velocity, indicating that increased resistance at higher velocities was felt at further stiffer positions and, thus, that the velocity dependence of spasticity may also be position-dependent. This finding indicates the need to control velocity in spasticity evaluation, which is achieved with the MSE. Quantitative measurements of spasticity, stiffness, and ROM can lead to more accurate characterizations of pathological conditions and outcome evaluations of interventions, potentially contributing to better healthcare services for patients with neurological disorders such as cerebral palsy, spinal cord injury, traumatic brain injury, and stroke.

  10. Design and analysis of composite structures with stress concentrations

    NASA Technical Reports Server (NTRS)

    Garbo, S. P.

    1983-01-01

    An overview of an analytic procedure which can be used to provide comprehensive stress and strength analysis of composite structures with stress concentrations is given. The methodology provides designer/analysts with a user-oriented procedure which, within acceptable engineering accuracy, accounts for the effects of a wide range of application design variables. The procedure permits the strength of arbitrary laminate constructions under general bearing/bypass load conditions to be predicted with only unnotched unidirectional strength and stiffness input data required. Included is a brief discussion of the relevancy of this analysis to the design of primary aircraft structure; an overview of the analytic procedure with theory/test correlations; and an example of the use and interaction of this strength analysis relative to the design of high-load transfer bolted composite joints.

  11. A fast collocation method for a variable-coefficient nonlocal diffusion model

    NASA Astrophysics Data System (ADS)

    Wang, Che; Wang, Hong

    2017-02-01

    We develop a fast collocation scheme for a variable-coefficient nonlocal diffusion model, for which a numerical discretization would yield a dense stiffness matrix. The development of the fast method is achieved by carefully handling the variable coefficients appearing inside the singular integral operator and exploiting the structure of the dense stiffness matrix. The resulting fast method reduces the computational work from O (N3) required by a commonly used direct solver to O (Nlog ⁡ N) per iteration and the memory requirement from O (N2) to O (N). Furthermore, the fast method reduces the computational work of assembling the stiffness matrix from O (N2) to O (N). Numerical results are presented to show the utility of the fast method.

  12. The mechanism of bolt loading

    NASA Technical Reports Server (NTRS)

    Lee, H. M.

    1992-01-01

    It is shown that the mechanism of bolt loading for preloaded fasteners can be effectively portrayed through simple spring models and some algebraic manipulations. Understanding schematically what is involved in such joints provides insight into the distribution of loads. The developed equations confirm that for both symmetric and nonsymmetric joints the loading plane factor and the stiffness factor directly affect the load seen in preloaded fasteners. The manner in which an external loading is transferred through the joint can be explained as energy dissipated in the various springs of both the abutment and the bolt itself.

  13. What makes patients aware of their artificial knee joint?

    PubMed

    Loth, F L; Liebensteiner, M C; Giesinger, J M; Giesinger, K; Bliem, H R; Holzner, B

    2018-01-08

    Joint awareness was recently introduced as a new concept for outcome assessment after total knee arthroplasty (TKA). Findings from qualitative and psychometric studies suggest that joint awareness is a distinct concept especially relevant to patients with good surgical outcome and patients at late follow-up time points. The aim of this study was to improve the understanding of the concept of joint awareness by identifying situations in which patients are aware of their artificial knee joint and to investigate what bodily sensations and psychological factors raise a patient's awareness of her/his knee. In addition, we evaluated the relative importance of patient-reported outcome parameters that are commonly assessed in orthopaedics. Qualitative interviews were conducted with patients being at least 12 months after TKA. The interviews focused on when, where and for what reasons patients were aware of their artificial knee joint. To evaluate the relative importance of 'joint awareness' after TKA among nine commonly assessed outcome parameters (e.g. pain or stiffness), we collected importance ratings ('0' indicating no importance at all and '10' indicating high importance). We conducted interviews with 40 TKA patients (mean age 69.0 years; 65.0% female). Joint awareness was found to be frequently triggered by kneeling on the floor (30%), climbing stairs (25%), and starting up after resting (25%). Patients reported joint awareness to be related to activities of daily living (68%), specific movements (60%), or meteoropathy (18%). Sensations causing joint awareness included pain (45%) or stiffness (15%). Psychological factors raising a patient's awareness of his/her knee comprised for example feelings of insecurity (15%), and fears related to revision surgeries, inflammations or recurring pain (8%). Patients' importance ratings of outcome parameters were generally high and did not allow differentiating clearly among them. We have identified a wide range of situations, activities, movements and psychological factors contributing to patients' awareness of their artificial knee joints. This improves the understanding of the concept of joint awareness and of a patient's perception of his/her artificial knee joint. The diversity of sensations and factors raising patient's awareness of their joint encourages taking a broader perspective on outcome after TKA.

  14. Adjustable hinge permits movement of knee in plaster cast

    NASA Technical Reports Server (NTRS)

    Maley, W. E.

    1967-01-01

    Metal knee hinge with an adjustable sleeve worn on the outside of a leg cast facilitates movement of the knee joint. This helps eliminate stiffness of the knee and eliminates bulkiness and adjustment difficulty.

  15. The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness.

    PubMed

    Shepherd, Max K; Rouse, Elliott J

    2017-12-01

    Most commercially available prosthetic feet do not exhibit a biomimetic torque-angle relationship, and are unable to modulate their mechanics to assist with other mobility tasks, such as stairs and ramps. In this paper, we present a quasi-passive ankle-foot prosthesis with a customizable torque-angle curve and an ability to quickly modulate ankle stiffness between tasks. The customizable torque-angle curve is obtained with a cam-based transmission and a fiberglass leaf spring. To achieve variable stiffness, the leaf spring's support conditions can be actively modulated by a small motor, shifting the torque-angle curve to be more or less stiff. We introduce the design, characterize the available torque-angle curves, and present kinematics from a transtibial amputee subject performing level-ground walking, stair ascent/descent, and ramp ascent/descent. The subject exhibited a more normative range of motion on stairs and ramps at lower stiffness levels, and preferred different stiffness levels for each task. Paired with an appropriate intent recognition system, our novel ankle prosthesis could improve gait biomechanics during walking and many other mobility tasks.

  16. Bonded joint and method. [for reducing peak shear stress in adhesive bonds

    NASA Technical Reports Server (NTRS)

    Sainsbury-Carter, J. B. (Inventor)

    1974-01-01

    An improved joint is described for reducing the peak shear stress in adhesive bonds when adhesives are used to bond two materials which are in a lapped relationship and which differ in value of modulus of elasticity. An insert placed between the adhesive and one of the two materials acts to cushion the discontinuity of material stiffness thereby reducing the peak shear stress in the adhesive bond.

  17. Hand Surgery In World War II. Medical Department, United States Army,

    DTIC Science & Technology

    1955-09-01

    Few of these patients presented deep cicatrices , latent infection was minimal, and as a rule the position of function was maintained. DEBARKATION...HOSPITAL 217 Many patients were received with large dorsal cicatrices which, although healed, were unstable. Joints and tendons not directly injured by...burns were frequently damaged by constriction and immobility because of superimposed cicatrices . Joint stiffness was likely to be even more pronounced

  18. Ankle Joint Intrinsic Dynamics is More Complex than a Mass-Spring-Damper Model.

    PubMed

    Sobhani Tehrani, Ehsan; Jalaleddini, Kian; Kearney, Robert E

    2017-09-01

    This paper describes a new small signal parametric model of ankle joint intrinsic mechanics in normal subjects. We found that intrinsic ankle mechanics is a third-order system and the second-order mass-spring-damper model, referred to as IBK, used by many researchers in the literature cannot adequately represent ankle dynamics at all frequencies in a number of important tasks. This was demonstrated using experimental data from five healthy subjects with no voluntary muscle contraction and at seven ankle positions covering the range of motion. We showed that the difference between the new third-order model and the conventional IBK model increased from dorsi to plantarflexed position. The new model was obtained using a multi-step identification procedure applied to experimental input/output data of the ankle joint. The procedure first identifies a non-parametric model of intrinsic joint stiffness where ankle position is the input and torque is the output. Then, in several steps, the model is converted into a continuous-time transfer function of ankle compliance, which is the inverse of stiffness. Finally, we showed that the third-order model is indeed structurally consistent with agonist-antagonist musculoskeletal structure of human ankle, which is not the case for the IBK model.

  19. Measuring Multi-Joint Stiffness during Single Movements: Numerical Validation of a Novel Time-Frequency Approach

    PubMed Central

    Piovesan, Davide; Pierobon, Alberto; DiZio, Paul; Lackner, James R.

    2012-01-01

    This study presents and validates a Time-Frequency technique for measuring 2-dimensional multijoint arm stiffness throughout a single planar movement as well as during static posture. It is proposed as an alternative to current regressive methods which require numerous repetitions to obtain average stiffness on a small segment of the hand trajectory. The method is based on the analysis of the reassigned spectrogram of the arm's response to impulsive perturbations and can estimate arm stiffness on a trial-by-trial basis. Analytic and empirical methods are first derived and tested through modal analysis on synthetic data. The technique's accuracy and robustness are assessed by modeling the estimation of stiffness time profiles changing at different rates and affected by different noise levels. Our method obtains results comparable with two well-known regressive techniques. We also test how the technique can identify the viscoelastic component of non-linear and higher than second order systems with a non-parametrical approach. The technique proposed here is very impervious to noise and can be used easily for both postural and movement tasks. Estimations of stiffness profiles are possible with only one perturbation, making our method a useful tool for estimating limb stiffness during motor learning and adaptation tasks, and for understanding the modulation of stiffness in individuals with neurodegenerative diseases. PMID:22448233

  20. Synthesis, Characterization, and Modeling of Nanotube Materials with Variable Stiffness Tethers

    NASA Technical Reports Server (NTRS)

    Frankland, S. J. V.; Herzog, M. N.; Odegard, G. M.; Gates, T. S.; Fay, C. C.

    2004-01-01

    Synthesis, mechanical testing, and modeling have been performed for carbon nanotube based materials. Tests using nanoindentation indicated a six-fold enhancement in the storage modulus when comparing the base material (no nanotubes) to the composite that contained 5.3 wt% of nanotubes. To understand how crosslinking the nanotubes may further alter the stiffness, a model of the system was constructed using nanotubes crosslinked with a variable stiffness tether (VST). The model predicted that for a composite with 5 wt% nanotubes at random orientations, crosslinked with the VST, the bulk Young's modulus was reduced by 30% compared to the noncrosslinked equivalent.

  1. The use of self-report questions to examine the prevalence of musculoskeletal problems: a test-retest study.

    PubMed

    Gill, Tiffany K; Tucker, Graeme R; Avery, Jodie C; Shanahan, E Michael; Menz, Hylton B; Taylor, Anne W; Adams, Robert J; Hill, Catherine L

    2016-02-24

    Case definition has long been an issue for comparability of results obtained for musculoskeletal pain prevalence, however the test-retest reliability of questions used to determine joint pain prevalence has not been examined. The objective of this study was to determine question reliability and the impact of question wording, ordering and the time between questions on responses. A Computer Assisted Telephone Interviewing (CATI) survey was used to re-administer questions collected as part of a population-based longitudinal cohort study. On two different occasions questions were asked of the same sample of 203 community dwelling respondents (which were initially randomly selected) aged 18 years and over at two time points 14 to 27 days apart (average 15 days). Reliability of the questions was assessed using Cohen's kappa (κ) and intraclass correlation coefficient (ICC) and whether question wording and period effects existed was assessed using a crossover design. The self-reported prevalence of doctor diagnosed arthritis demonstrated excellent reliability (κ = 0.84 and κ = 0.79 for questionnaires 1 and 2 respectively). The reliability of questions relating to musculoskeletal pain and/or stiffness ranged from moderate to excellent for both types of questions, that is, those related to ever having joint pain on most days for at least a month (κ = 0.52 to κ = 0.95) and having pain and/or stiffness on most days for the last month (κ = 0.52 to κ = 0.90). However there was an effect of question wording on the results obtained for hand, foot and back pain and/or stiffness indicating that the area of pain may influence prevalence estimates. Joint pain and stiffness questions are reliable and can be used to determine prevalence. However, question wording and pain area may impact on estimates with issues such as pain perception and effect on activities playing a possible role in the recall of musculoskeletal pain.

  2. Stiffness control of magnetorheological gels for adaptive tunable vibration absorber

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Kee; Kim, Hye Shin; Kim, Young-Keun

    2017-01-01

    In this study, a stiffness feedback control system for magnetorheological (MR) gel—a smart material of variable stiffness—is proposed, toward the design of a tunable vibration absorber that can adaptively tune to a time varying disturbance in real time. A PID controller was designed to track the required stiffness of the MR gel by controlling the magnitude of the target external magnetic field pervading the MR gel. This paper proposes a novel magnetic field generator that could produce a variable magnetic field with low energy consumption. The performance of the MR gel stiffness control was validated through experiments that showed the MR gel absorber system could be automatically tuned from 56 Hz to 67 Hz under a field of 100 mT to minimize the vibration of the primary system.

  3. Biomechanical comparisons of single- and double-legged drop jumps with changes in drop height.

    PubMed

    Wang, L-I; Peng, H-T

    2014-06-01

    The purpose of this study was to compare the biomechanics of single- and double-legged drop jumps (SDJ vs. DDJ) with changes in drop height. Jumping height, ground contact time, reactive strength index, ground reaction force, loading rate of ground reaction force, joint power and stiffness were measured in 12 male college students during SDJ from 20-, 30-, 40-, and 50-cm heights and DDJ from of 20- and 40-cm heights. The peak impact force was increased with the incremental drop height during SDJs. The jumping height and leg and ankle stiffness of SDJ30 were greater than those of SDJ40 and SDJ50. The knee and hip stiffnesses of SDJ30 were greater than those of SDJ50. The impact forces of SDJ30-50 were greater than those of DDJ40. The leg, ankle, knee and hip joint stiffnesses of SDJ20-30 were greater than those of DDJ20 and DDJ40. The propulsive forces of SDJ20-50 were greater than those of DDJ20 and DDJ40. The jumping height of SDJ30 was greater than that of DDJ20. Drop height of 30 cm was recommended during single-legged drop jump with the best biomechanical benefit. Single-legged drop jump from 20-30 cm could provide comparable intensity to double-legged drop jump from 40 cm. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Mechanical properties of hyaline and repair cartilage studied by nanoindentation.

    PubMed

    Franke, O; Durst, K; Maier, V; Göken, M; Birkholz, T; Schneider, H; Hennig, F; Gelse, K

    2007-11-01

    Articular cartilage is a highly organized tissue that is well adapted to the functional demands in joints but difficult to replicate via tissue engineering or regeneration. Its viscoelastic properties allow cartilage to adapt to both slow and rapid mechanical loading. Several cartilage repair strategies that aim to restore tissue and protect it from further degeneration have been introduced. The key to their success is the quality of the newly formed tissue. In this study, periosteal cells loaded on a scaffold were used to repair large partial-thickness cartilage defects in the knee joint of miniature pigs. The repair cartilage was analyzed 26 weeks after surgery and compared both morphologically and mechanically with healthy hyaline cartilage. Contact stiffness, reduced modulus and hardness as key mechanical properties were examined in vitro by nanoindentation in phosphate-buffered saline at room temperature. In addition, the influence of tissue fixation with paraformaldehyde on the biomechanical properties was investigated. Although the repair process resulted in the formation of a stable fibrocartilaginous tissue, its contact stiffness was lower than that of hyaline cartilage by a factor of 10. Fixation with paraformaldehyde significantly increased the stiffness of cartilaginous tissue by one order of magnitude, and therefore, should not be used when studying biomechanical properties of cartilage. Our study suggests a sensitive method for measuring the contact stiffness of articular cartilage and demonstrates the importance of mechanical analysis for proper evaluation of the success of cartilage repair strategies.

  5. Vertical stiffness is not related to anterior cruciate ligament elongation in professional rugby union players.

    PubMed

    Serpell, Benjamin G; Scarvell, Jennie M; Pickering, Mark R; Ball, Nick B; Perriman, Diana; Warmenhoven, John; Smith, Paul N

    2016-01-01

    Novel research surrounding anterior cruciate ligament (ACL) injury is necessary because ACL injury rates have remained unchanged for several decades. An area of ACL risk mitigation which has not been well researched relates to vertical stiffness. The relationship between increased vertical stiffness and increased ground reaction force suggests that vertical stiffness may be related to ACL injury risk. However, given that increased dynamic knee joint stability has been shown to be associated with vertical stiffness, it is possible that modification of vertical stiffness could help to protect against injury. We aimed to determine whether vertical stiffness is related to measures known to load, or which represent loading of, the ACL. This was a cross-sectional observational study of 11 professional Australian rugby players. Knee kinematics and ACL elongation were measured from a 4-dimensional model of a hopping task which simulated the change of direction manoeuvre typically observed when non-contact ACL injury occurs. The model was generated from a CT scan of the participant's knee registered frame by frame to fluoroscopy images of the hopping task. Vertical stiffness was calculated from force plate data. There was no association found between vertical stiffness and anterior tibial translation (ATT) or ACL elongation (r=-0.05; p=0.89, and r=-0.07; p=0.83, respectively). ATT was related to ACL elongation (r=0.93; p=0.0001). Vertical stiffness was not associated with ACL loading in this cohort of elite rugby players but a novel method for measuring ACL elongation in vivo was found to have good construct validity.

  6. Shape Memory Alloy-Based Soft Gripper with Variable Stiffness for Compliant and Effective Grasping.

    PubMed

    Wang, Wei; Ahn, Sung-Hoon

    2017-12-01

    Soft pneumatic actuators and motor-based mechanisms being concomitant with the cumbersome appendages have many challenges to making the independent robotic system with compact and lightweight configuration. Meanwhile, shape memory actuators have shown a promising alternative solution in many engineering applications ranging from artificial muscle to aerospace industry. However, one of the main limitations of such systems is their inherent softness resulting in a small actuation force, which prevents them from more effective applications. This issue can be solved by combining shape memory actuators and the mechanism of stiffness modulation. As a first, this study describes a shape memory alloy-based soft gripper composed of three identical fingers with variable stiffness for adaptive grasping in low stiffness state and effective holding in high stiffness state. Each finger with two hinges is fabricated through integrating soft composite actuator with stiffness changeable material where each hinge can approximately achieve a 55-fold changeable stiffness independently. Besides, each finger with two hinges can actively achieve multiple postures by both selectively changing the stiffness of hinges and actuating the relevant SMA wire. Based on these principles, the gripper is applicable for grasping objects with deformable shapes and varying shapes with a large range of weight where its maximum grasping force is increased to ∼10 times through integrating with the stiffness changeable mechanism. The final demonstration shows that the finger with desired shape-retained configurations enables the gripper to successfully pick up a frustum-shaped object.

  7. Foot Health

    MedlinePlus

    ... straight across and not too short Your foot health can be a clue to your overall health. For example, joint stiffness could mean arthritis. Tingling ... foot checks are an important part of your health care. If you have foot problems, be sure ...

  8. Hunter syndrome

    MedlinePlus

    ... from joint stiffness) Tests may include: Enzyme study Genetic testing for a change in the iduronate sulfatase gene ... genetic carrier and are considering having children ... who have a family history of MPS II. Prenatal testing is available. Carrier testing for female relatives of ...

  9. Gout

    MedlinePlus

    ... red, hot and stiff joints. Gout happens when uric acid builds up in your body. Uric acid comes from the breakdown of substances called purines. ... liver, dried beans and peas, and anchovies. Normally, uric acid dissolves in the blood. It passes through the ...

  10. Angular Deformities of the Lower Limb in Children

    PubMed Central

    Espandar, Ramin; Mortazavi, Seyed Mohammad-Javad; Baghdadi, Taghi

    2010-01-01

    Angular deformities of the lower limbs are common during childhood. In most cases this represents a variation in the normal growth pattern and is an entirely benign condition. Presence of symmetrical deformities and absence of symptoms, joint stiffness, systemic disorders or syndromes indicates a benign condition with excellent long-term outcome. In contrast, deformities which are asymmetrical and associated with pain, joint stiffness, systemic disorders or syndromes may indicate a serious underlying cause and require treatment. Little is known about the relationship between sport participation and body adaptations during growth. Intense soccer participation increases the degree of genu varum in males from the age of 16. Since, according to some investigations, genu varum predisposes individuals to more injuries, efforts to reduce the development of genu varum in soccer players are warranted. In this article major topics of angular deformities of the knees in pediatric population are practically reviewed. PMID:22375192

  11. Numerical and experimental analysis of a vibration isolator equipped with a negative stiffness system

    NASA Astrophysics Data System (ADS)

    Palomares, E.; Nieto, A. J.; Morales, A. L.; Chicharro, J. M.; Pintado, P.

    2018-02-01

    This paper presents a Negative Stiffness System (NSS) based on a set of two double-acting pneumatic linear actuators (PLA). The NSS is added to a system with a single degree of freedom, which consists of a sprung mass and a pneumatic spring. One end of each PLA is jointed to the sprung mass while the other end is jointed to the vibrating frame. In addition, the PLAs are symmetrically arranged so that they remain horizontal while the sprung mass is in static conditions. When the rear chamber is pressurised, the vertical component of the force applied by the PLAs will work against the pneumatic spring reducing the dynamic resonance frequency of the overall system. Experimental tests and simulations showed improvements regarding sprung mass isolation in comparison to the passive system without NSS, decreasing the resonance frequency by up to 58 % and improving the vibration attenuation for different experimental excitations.

  12. Martial arts training attenuates arterial stiffness in middle aged adults.

    PubMed

    Douris, Peter C; Ingenito, Teresa; Piccirillo, Barbara; Herbst, Meredith; Petrizzo, John; Cherian, Vincen; McCutchan, Christopher; Burke, Caitlin; Stamatinos, George; Jung, Min-Kyung

    2013-09-01

    Arterial stiffness increases with age and is related to an increased risk of coronary artery disease. Poor trunk flexibility has been shown to be associated with arterial stiffness in middle-aged subjects. The purpose of our research study was to measure arterial stiffness and flexibility in healthy middle-aged martial artists compared to age and gender matched healthy sedentary controls. Ten martial artists (54.0 ± 2.0 years), who practice Soo Bahk Do (SBD), a Korean martial art, and ten sedentary subjects (54.7 ± 1.8 years) for a total of twenty subjects took part in this cross-sectional study. Arterial stiffness was assessed in all subjects using pulse wave velocity (PWV), a recognized index of arterial stiffness. Flexibility of the trunk and hamstring were also measured. The independent variables were the martial artists and matched sedentary controls. The dependent variables were PWV and flexibility. There were significant differences, between the SBD practitioners and sedentary controls, in PWV (P = 0.004), in trunk flexibility (P= 0.002), and in hamstring length (P= 0.003). The middle-aged martial artists were more flexible in their trunk and hamstrings and had less arterial stiffness compared to the healthy sedentary controls. The flexibility component of martial art training or flexibility exercises in general may be considered as a possible intervention to reduce the effects of aging on arterial stiffness.

  13. Martial Arts Training Attenuates Arterial Stiffness in Middle Aged Adults

    PubMed Central

    Douris, Peter C.; Ingenito, Teresa; Piccirillo, Barbara; Herbst, Meredith; Petrizzo, John; Cherian, Vincen; McCutchan, Christopher; Burke, Caitlin; Stamatinos, George; Jung, Min-Kyung

    2013-01-01

    Purpose Arterial stiffness increases with age and is related to an increased risk of coronary artery disease. Poor trunk flexibility has been shown to be associated with arterial stiffness in middle-aged subjects. The purpose of our research study was to measure arterial stiffness and flexibility in healthy middle-aged martial artists compared to age and gender matched healthy sedentary controls. Methods Ten martial artists (54.0 ± 2.0 years), who practice Soo Bahk Do (SBD), a Korean martial art, and ten sedentary subjects (54.7 ± 1.8 years) for a total of twenty subjects took part in this cross-sectional study. Arterial stiffness was assessed in all subjects using pulse wave velocity (PWV), a recognized index of arterial stiffness. Flexibility of the trunk and hamstring were also measured. The independent variables were the martial artists and matched sedentary controls. The dependent variables were PWV and flexibility. Results There were significant differences, between the SBD practitioners and sedentary controls, in PWV (P = 0.004), in trunk flexibility (P= 0.002), and in hamstring length (P= 0.003). Conclusion The middle-aged martial artists were more flexible in their trunk and hamstrings and had less arterial stiffness compared to the healthy sedentary controls. The flexibility component of martial art training or flexibility exercises in general may be considered as a possible intervention to reduce the effects of aging on arterial stiffness. PMID:24427479

  14. Fatigue and Fracture Characterization of GlasGridRTM Reinforced Asphalt Concrete Pavement

    NASA Astrophysics Data System (ADS)

    Safavizadeh, Seyed Amirshayan

    The purpose of this research is to develop an experimental and analytical framework for describing, modeling, and predicting the reflective cracking patterns and crack growth rates in GlasGridRTM-reinforced asphalt pavements. In order to fulfill this objective, the effects of different interfacial conditions (mixture and tack coat type, and grid opening size) on reflective cracking-related failure mechanisms and the fatigue and fracture characteristics of fiberglass grid-reinforced asphalt concrete beams were studied by means of four- and threepoint bending notched beam fatigue tests (NBFTs) and cyclic and monotonic interface shear tests. The digital image correlation (DIC) technique was utilized for obtaining the displacement and strain contours of specimen surfaces during each test. The DIC analysis results were used to develop crack tip detection methods that were in turn used to determine interfacial crack lengths in the shear tests, and vertical and horizontal (interfacial) crack lengths in the notched beam fatigue tests. Linear elastic fracture mechanics (LEFM) principles were applied to the crack length data to describe the crack growth. In the case of the NBFTs, a finite element (FE) code was developed and used for modeling each beam at different stages of testing and back-calculating the stress intensity factors (SIFs) for the vertical and horizontal cracks. The local effect of reinforcement on the stiffness of the system at a vertical crack-interface intersection or the resistance of the grid system to the deflection differential at the joint/crack (hereinafter called joint stiffness) for GlasGrid-reinforced asphalt concrete beams was determined by implementing a joint stiffness parameter into the finite element code. The strain level dependency of the fatigue and fracture characteristics of the GlasGrid-reinforced beams was studied by performing four-point bending notched beam fatigue tests at strain levels of 600, 750, and 900 microstrain. These beam tests were conducted at 15°C, 20°C, and 23°C, with the main focus being to find the characteristics at 20°C. The results obtained from the tests at the different temperatures were used to investigate the effects of temperature on the reflective cracking performance of the gridreinforced beam specimens. The temperature tests were also used to investigate the validity of the time-temperature superposition (t-TS) principle in shear and the beam fatigue performance of the grid-reinforced specimens. The NBFT results suggest that different interlayer conditions do not reflect a unique failure mechanism, and thus, in order to predict and model the performance of grid-reinforced pavement, all the mechanisms involved in weakening its structural integrity, including damage within the asphalt layers and along the interface, must be considered. The shear and beam fatigue test results suggest that the grid opening size, interfacial bond quality, and mixture type play important roles in the reflective cracking performance of GlasGrid-reinforced asphalt pavements. According to the NBTF results, GlasGrid reinforcement retards reflective crack growth by stiffening the composite system and introducing a joint stiffness parameter. The results also show that the higher the bond strength and interlayer stiffness values, the higher the joint stiffness and retardation effects. The t-TS studies proved the validity of this principle in terms of the reflective crack growth of the grid-reinforced beam specimens and the shear modulus and shear strength of the grid-reinforced interfaces.

  15. Ankle Joint Angle and Lower Leg Musculotendinous Unit Responses to Cryotherapy.

    PubMed

    Akehi, Kazuma; Long, Blaine C; Warren, Aric J; Goad, Carla L

    2016-09-01

    Akehi, K, Long, BC, Warren, AJ, and Goad, CL. Ankle joint angle and lower leg musculotendinous unit responses to cryotherapy. J Strength Cond Res 30(9): 2482-2492, 2016-The use of cold application has been debated for its influence on joint range of motion (ROM) and stiffness. The purpose of this study was to determine whether a 30-minute ice bag application to the plantarflexor muscles or ankle influences passive ankle dorsiflexion ROM and lower leg musculotendinous stiffness (MTS). Thirty-five recreationally active college-aged individuals with no history of lower leg injury 6 months before data collection volunteered. On each testing day, we measured maximum passive ankle dorsiflexion ROM (°) and plantarflexor torque (N·m) on an isokinetic dynamometer to calculate the passive plantarflexor MTS (N·m per degree) at 4 joint angles before, during, and after a treatment. Surface electromyography amplitudes (μV), and skin surface and ambient air temperature (°C) were also measured. Subjects received an ice bag to the posterior lower leg, ankle joint, or nothing for 30 minutes in different days. Ice bag application to the lower leg and ankle did not influence passive ROM (F(12,396) = 0.67, p = 0.78). Passive torque increased after ice bag application to the lower leg (F(12,396) = 2.21, p = 0.011). Passive MTS at the initial joint angle increased after ice bag application to the lower leg (F(12,396) = 2.14, p = 0.014) but not at the other joint angles (p > 0.05). Surface electromyography amplitudes for gastrocnemius and soleus muscles increased after ice application to the lower leg (F(2,66) = 5.61, p = 0.006; F(12,396) = 3.60, p < 0.001). Ice bag application to the lower leg and ankle joint does not alter passive dorsiflexion ROM but increases passive ankle plantarflexor torque in addition to passive ankle plantarflexor MTS at the initial joint angle.

  16. Evolution of the Deformation Behavior of Sn-Rich Solders during Cyclic Fatigue

    NASA Astrophysics Data System (ADS)

    Wentlent, Luke Arthur

    Continuous developments in the electronics industry have provided a critical need for a quantitative, fundamental understanding of the behavior of SnAgCu (SAC) solders in both isothermal and thermal fatigue conditions. This study examines the damage behavior of Sn-based solders in a constant amplitude and variable amplitude environment. In addition, damage properties are correlated with crystal orientation and slip behavior. Select solder joints were continuously characterized and tested repeatedly in order to eliminate the joint to joint variation due to the anisotropy of beta-Sn. Characterization was partitioned into three different categories: effective properties and slip behavior, creep mechanisms and crystal morphology development, and atomic behavior and evolution. Active slip systems were correlated with measured properties. Characterization of the mechanical behavior was performed by the calculation and extrapolation of the elastic modulus, work, effective stiffness, Schmid factors, and time-dependent plasticity (creep). Electron microscopy based characterization methods included Scanning Electron Microscopy (SEM), Electron Backscattering Diffraction (EBSD), and Transmission Electron Microscopy (TEM). Testing showed a clear evolution of the steady-state creep mechanism when the cycling amplitudes were varied, from dislocation controlled to diffusion controlled creep. Dislocation behavior was examined and shown to evolve differently in single amplitude vs. variable amplitude testing. Finally, the mechanism of the recrystallization behavior of the beta-Sn was observed. This work fills a gap in the literature, providing a systematic study which identifies how the damage behavior in Sn-alloys depends upon the previous damage. A link is made between the observed creep behavior and the dislocation observations, providing a unified picture. Information developed in this work lays a stepping stone to future fundamental analyses as well as clarifying aspects of the mechanistic behavior of Sn and Sn-based alloys.

  17. Exploring novel objective functions for simulating muscle coactivation in the neck.

    PubMed

    Mortensen, J; Trkov, M; Merryweather, A

    2018-04-11

    Musculoskeletal modeling allows for analysis of individual muscles in various situations. However, current techniques to realistically simulate muscle response when significant amounts of intentional coactivation is required are inadequate. This would include stiffening the neck or spine through muscle coactivation in preparation for perturbations or impacts. Muscle coactivation has been modeled previously in the neck and spine using optimization techniques that seek to maximize the joint stiffness by maximizing total muscle activation or muscle force. These approaches have not sought to replicate human response, but rather to explore the possible effects of active muscle. Coactivation remains a challenging feature to include in musculoskeletal models, and may be improved by extracting optimization objective functions from experimental data. However, the components of such an objective function must be known before fitting to experimental data. This study explores the effect of components in several objective functions, in order to recommend components to be used for fitting to experimental data. Four novel approaches to modeling coactivation through optimization techniques are presented, two of which produce greater levels of stiffness than previous techniques. Simulations were performed using OpenSim and MATLAB cooperatively. Results show that maximizing the moment generated by a particular muscle appears analogous to maximizing joint stiffness. The approach of optimizing for maximum moment generated by individual muscles may be a good candidate for developing objective functions that accurately simulate muscle coactivation in complex joints. This new approach will be the focus of future studies with human subjects. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Determination of torque-limits for human and cat lumbar spine specimens during displacement-controlled physiological motions.

    PubMed

    Ianuzzi, Allyson; Pickar, Joel G; Khalsa, Partap S

    2009-01-01

    Quadruped animal models have been validated and used as biomechanical models for the lumbar spine. The biomechanics of the cat lumbar spine has not been well characterized, even though it is a common model used in neuromechanical studies. Compare the physiological ranges of motion and determine torque-limits for cat and human lumbar spine specimens during physiological motions. Biomechanics study. Cat and human lumbar spine specimens. Intervertebral angle (IVA), joint moment, yield point, torque-limit, and correlation coefficients. Cat (L2-sacrum) and human (T12-sacrum) lumbar spine specimens were mechanically tested to failure during displacement-controlled extension (E), lateral bending (LB), and axial rotation (AR). Single trials consisted of 10 cycles (10mm/s or 5 degrees /s) to a target displacement where the magnitude of the target displacement was increased for subsequent trials until failure occurred. Whole-lumbar stiffness, torque at yield point, and joint stiffness were determined. Scaling relationships were established using equations analogous to those that describe the load response of elliptically shaped beams. IVA magnitudes for cat and human lumbar spines were similar during physiological motions. Human whole-lumbar and joint stiffness magnitudes were significantly greater than those for cat spine specimens (p<.05). Torque-limits were also greater for humans compared with cats. Scaling relationships with high correlation (R(2) greater than 0.77) were established during later LB and AR. The current study defined "physiological ranges of movement" for human and cat lumbar spine specimens during displacement-controlled testing, and should be observed in future biomechanical studies conducted under displacement control.

  19. Coexistence of Ankylosing Spondylitis and Klinefelter's Syndrome

    PubMed Central

    Kobak, Şenol; Yalçin, Murat; Karadeniz, Muamer; Oncel, Guray

    2013-01-01

    Ankylosing spondylitis is a chronic inflammatory disease characterized by inflammatory lower back pain and morning stiffness and accompanied by spine and sacroiliac joint involvement. Klinefelter's syndrome is a genetic condition that only affects males. Affected males have an extra X chromosome. This paper reports a 30-years-old male on followup with the diagnosis of Klinefelters syndrome. The patient admitted with complaints of inflammatory lower back, and neck pain and morning stiffness and was diagnosed with ankylosing spondylitis. Nonsteroidal anti-inflammatory drug and salazopyrine treatment resulted in significant regression in his complaints. PMID:23762731

  20. Coexistence of Ankylosing Spondylitis and Klinefelter's Syndrome.

    PubMed

    Kobak, Senol; Yalçin, Murat; Karadeniz, Muamer; Oncel, Guray

    2013-01-01

    Ankylosing spondylitis is a chronic inflammatory disease characterized by inflammatory lower back pain and morning stiffness and accompanied by spine and sacroiliac joint involvement. Klinefelter's syndrome is a genetic condition that only affects males. Affected males have an extra X chromosome. This paper reports a 30-years-old male on followup with the diagnosis of Klinefelters syndrome. The patient admitted with complaints of inflammatory lower back, and neck pain and morning stiffness and was diagnosed with ankylosing spondylitis. Nonsteroidal anti-inflammatory drug and salazopyrine treatment resulted in significant regression in his complaints.

  1. Motor control: the importance of stiffness.

    PubMed

    Hooper, Scott L

    2006-04-18

    An octopus brings food grasped by a tentacle to its mouth by bending the tentacle around a joint formed by stiffened distal and proximal tentacle muscles, and thus may use motor control strategies analogous to those in animals with articulated limbs.

  2. Adhesive-bonded scarf and stepped-lap joints

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1973-01-01

    Continuum mechanics solutions are derived for the static load-carrying capacity of scarf and stepped-lap adhesive-bonded joints. The analyses account for adhesive plasticity and adherend stiffness imbalance and thermal mismatch. The scarf joint solutions include a simple algebraic formula which serves as a close lower bound, within a small fraction of a per cent of the true answer for most practical geometries and materials. Digital computer programs were developed and, for the stepped-lap joints, the critical adherend and adhesive stresses are computed for each step. The scarf joint solutions exhibit grossly different behavior from that for double-lap joints for long overlaps inasmuch as that the potential bond shear strength continues to increase with indefinitely long overlaps on the scarf joints. The stepped-lap joint solutions exhibit some characteristics of both the scarf and double-lap joints. The stepped-lap computer program handles arbitrary (different) step lengths and thickness and the solutions obtained have clarified potentially weak design details and the remedies. The program has been used effectively to optimize the joint proportions.

  3. Hypothyroidism presenting as destructive arthropathy of the fingers.

    PubMed Central

    Gerster, J. C.; Quadri, P.; Saudan, Y.

    1985-01-01

    A patient presenting with destructive arthropathy of the proximal interphalangeal (PIP) joints of the hands is described. She was initially believed to have rheumatoid arthritis but non-steroidal anti-inflammatory drugs were of no help. The patient was subsequently found to have hypothyroidism and erosive osteoarthritis of the fingers. Joint swelling, pain and stiffness responded dramatically to thyroid hormone substitution. The PIP joint spaces reappeared on the radiographs within 9 months. This case suggest that hypothyroidism may induce destructive arthropathy of the finger joints. As thyroxine replacement may reverse the rheumatic complaints, hypothyroidism should be considered in the differential diagnosis of a destructive arthropathy of unclear aetiology. Images Figure 1 Figure 2 PMID:3983045

  4. Adaptive velocity-based six degree of freedom load control for real-time unconstrained biomechanical testing.

    PubMed

    Lawless, I M; Ding, B; Cazzolato, B S; Costi, J J

    2014-09-22

    Robotic biomechanics is a powerful tool for further developing our understanding of biological joints, tissues and their repair. Both velocity-based and hybrid force control methods have been applied to biomechanics but the complex and non-linear properties of joints have limited these to slow or stepwise loading, which may not capture the real-time behaviour of joints. This paper presents a novel force control scheme combining stiffness and velocity based methods aimed at achieving six degree of freedom unconstrained force control at physiological loading rates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Clinical study of Agnikarma and Panchatikta Guggulu in the management of Sandhivata (osteoartheritis of knee joint).

    PubMed

    Sharma, Aneesh Vasudeva; Dudhamal, Tukaram Sambhaji; Gupta, Sanjay Kumar; Mahanta, Vyasadeva

    2016-01-01

    Sandhivata is a disease described under Vatavyadhi and resembles osteoarthritis (OA) in respect to etiology, pathology, and clinical features. Knee joints are more prone to be affected by this disease because it is the most frequently involved joint in daily works. Acharya Sushruta has indicated Agnikarma , when severe pain occurs in Twak , Mamsa , Sira, Snayu , Sandhi , and Asthi due to Vata Prakopa . Panchatikta Guggulu is a formulation mentioned in Chakradatta and Bhaishajya Ratnavali in the context of Kushtha Roga where it is also indicated for Sandhigata Vata and Asthigata Vata . The aim of this study is to evaluate the comparative effect of Agnikarma alone and Agnikarma along with Panchatikta Guggulu orally in Janugata Sandhivata (OA of knee joint). Thirty-three patients of Janugata Sandhivata were registered and randomly divided into two groups. In Group A ( n = 18), Agnikarma was done with Panchadhatu Shalaka once every week for one month while in Group B ( n = 15), Agnikarma along with Panchatikta Guggulu orally was given for one month. Weekly assessment was done for relief in Sandhishula (pain), Sparshaasahyata (tenderness), Sandhisphutana (crepitus), Sandhigraha (stiffness) by subjective gradation, and range of movement (ROM) was recorded in research proforma. In Sandhishula , 86% relief was found in Group A whereas 77.78% relief was obtained in Group B. Sparshaasahyata was reduced by 69% in Group A while 87.78% in Group B. Nearly 39% improvement was seen in Sandhisphutana in Group A while 46.67% in Group B. In Sandhigraha , 63% relief was obtained in each of the groups. The patients got relief from the pain after first sitting of Agnikarma in both the groups. The relief was sustained for more than 3 months in most of the patients. There was no significant difference in radiological findings before and after treatment in both the groups. It was concluded that Agnikarma is effective in the management of pain in the Sandhivata . However, the addition of Panchatikta Guggulu in the treatment provides better efficacy on joint stiffness and crepitus. Further analysis showed that better relief in pain was observed in Group A while relief in tenderness, crepitus, and stiffness was found better in Group B.

  6. Application of a local linearization technique for the solution of a system of stiff differential equations associated with the simulation of a magnetic bearing assembly

    NASA Technical Reports Server (NTRS)

    Kibler, K. S.; Mcdaniel, G. A.

    1981-01-01

    A digital local linearization technique was used to solve a system of stiff differential equations which simulate a magnetic bearing assembly. The results prove the technique to be accurate, stable, and efficient when compared to a general purpose variable order Adams method with a stiff option.

  7. Exposure to wood smoke increases arterial stiffness and decreases heart rate variability in humans

    PubMed Central

    2013-01-01

    Background Emissions from biomass combustion are a major source of indoor and outdoor air pollution, and are estimated to cause millions of premature deaths worldwide annually. Whilst adverse respiratory health effects of biomass exposure are well established, less is known about its effects on the cardiovascular system. In this study we assessed the effect of exposure to wood smoke on heart rate, blood pressure, central arterial stiffness and heart rate variability in otherwise healthy persons. Methods Fourteen healthy non-smoking subjects participated in a randomized, double-blind crossover study. Subjects were exposed to dilute wood smoke (mean particle concentration of 314±38 μg/m3) or filtered air for three hours during intermittent exercise. Heart rate, blood pressure, central arterial stiffness and heart rate variability were measured at baseline and for one hour post-exposure. Results Central arterial stiffness, measured as augmentation index, augmentation pressure and pulse wave velocity, was higher after wood smoke exposure as compared to filtered air (p < 0.01 for all), and heart rate was increased (p < 0.01) although there was no effect on blood pressure. Heart rate variability (SDNN, RMSSD and pNN50; p = 0.003, p < 0.001 and p < 0.001 respectively) was decreased one hour following exposure to wood smoke compared to filtered air. Conclusions Acute exposure to wood smoke as a model of exposure to biomass combustion is associated with an immediate increase in central arterial stiffness and a simultaneous reduction in heart rate variability. As biomass is used for cooking and heating by a large fraction of the global population and is currently advocated as a sustainable alternative energy source, further studies are required to establish its likely impact on cardiovascular disease. Trial registration ClinicalTrials.gov, NCT01488500 PMID:23742058

  8. Space Station alpha joint bearing

    NASA Technical Reports Server (NTRS)

    Everman, Michael R.; Jones, P. Alan; Spencer, Porter A.

    1987-01-01

    Perhaps the most critical structural system aboard the Space Station is the Solar Alpha Rotary Joint which helps align the power generation system with the sun. The joint must provide structural support and controlled rotation to the outboard transverse booms as well as power and data transfer across the joint. The Solar Alpha Rotary Joint is composed of two transition sections and an integral, large diameter bearing. Alpha joint bearing design presents a particularly interesting problem because of its large size and need for high reliability, stiffness, and on orbit maintability. The discrete roller bearing developed is a novel refinement to cam follower technology. It offers thermal compensation and ease of on-orbit maintenance that are not found in conventional rolling element bearings. How the bearing design evolved is summarized. Driving requirements are reviewed, alternative concepts assessed, and the selected design is described.

  9. A comparison of pectoral fin ray morphology and its impact on fin ray flexural stiffness in labriform swimmers.

    PubMed

    Aiello, Brett R; Hardy, Adam R; Cherian, Chery; Olsen, Aaron M; Orsbon, Courtney P; Hale, Melina E; Westneat, Mark W

    2018-04-25

    The organization of tissues in appendages often affects their mechanical properties and function. In the fish family Labridae, swimming behavior is associated with pectoral fin flexural stiffness and morphology, where fins range on a continuum from stiff to relatively flexible fins. Across this diversity, pectoral fin flexural stiffness decreases exponentially along the length of any given fin ray, and ray stiffness decreases along the chord of the fin from the leading to trailing edge. In this study, we examine the morphological properties of fin rays, including the effective modulus in bending (E), second moment of area (I), segmentation, and branching patterns, and their impact on fin ray stiffness. We quantify intrinsic pectoral fin ray stiffness in similarly sized fins of two closely related species that employ fins of divergent mechanics, the flapping Gomphosus varius and the rowing Halichoeres bivittatus. While segmentation patterns and E were similar between species, measurements of I and the number of fin ray branch nodes were greater in G. varius than in H. bivittatus. A multiple regression model found that of these variables, I was always significantly correlated with fin ray flexural stiffness and that variation in I always explained the majority of the variation in flexural stiffness. Thus, while most of the morphological variables quantified in this study correlate with fin ray flexural stiffness, second moment of area is the greatest factor contributing to variation in flexural stiffness. Further, interspecific variation in fin ray branching pattern could be used as a means of tuning the effective stiffness of the fin webbing to differences in swimming behavior and hydrodynamics. The comparison of these results to other systems begins to unveil fundamental morphological features of biological beams and yields insight into the role of mechanical properties in fin deformation for aquatic locomotion. © 2018 Wiley Periodicals, Inc.

  10. Effects of walkbot gait training on kinematics, kinetics, and clinical gait function in paraplegia and quadriplegia.

    PubMed

    Hwang, Jongseok; Shin, Yongil; Park, Ji-Ho; Cha, Young Joo; You, Joshua Sung H

    2018-04-07

    The robotic-assisted gait training (RAGT) system has gained recognition as an innovative, effective paradigm to improve functional ambulation and activities of daily living in spinal cord injury and stroke. However, the effects of the Walkbot robotic-assisted gait training system with a specialized hip-knee-ankle actuator have never been examined in the paraplegia and quadriplegia population. The aim of this study was to determine the long-term effects of Walkbot training on clinical for hips and knee stiffness in individuals with paraplegia or quadriplegia. Nine adults with subacute or chronic paraplegia resulting from spinal cord injury or quadriplegia resulting from cerebral vascular accident (CVA) and/or hypoxia underwent progressive conventional gait retraining combined with the Walkbot RAGT for 5 days/week over an average of 43 sessions for 8 weeks. Clinical outcomes were measured with the Functional Ambulation Category (FAC), Modified Rankin Scale (MRS), Korean version of the Modified Barthel Index (K-MBI), Modified Ashworth Scale (MAS). Kinetic and kinematic data were collected via a built-in Walkbot program. Wilcoxon signed-rank tests showed significant positive intervention effects on K-MBI, maximal hip flexion and extension, maximal knee flexion, active torque in the knee joint, resistive torque, and stiffness in the hip joint (P <  0.05). These findings suggest that the Walkbot RAGT was effective for improving knee and hip kinematics and the active knee joint moment while decreasing hip resistive force. These improvements were associated with functional recovery in gait, balance, mobility and daily activities. These findings suggest that the Walkbot RAGT was effective for improving knee and hip kinematics and the active knee joint moment while decreasing hip resistive force. This is the first clinical evidence for intensive, long-term effects of the Walkbot RAGT on active or resistive moments and stiffness associated with spasticity and functional mobility in individuals with subacute or chronic paraplegia or quadriplegia who had reached a plateau in motor recovery after conventional therapy.

  11. The influence of artificially increased trunk stiffness on the balance recovery after a trip.

    PubMed

    van der Burg, J C E; Pijnappels, M; van Dieën, J H

    2007-07-01

    Falls occur frequently in the growing population of elderly. Since trunk control is critical for maintaining balance, the higher trunk stiffness in elderly people compared to the general population has been associated with their increased fall-risk. Theoretically, trunk stiffness may be beneficial for balance recovery in walking, i.e. after a trip. A stiff joint may provide a torque that restricts the perturbation effects and thereby reduces the probability of a fall. The aim of this study was to test whether trunk stiffness impaired or assisted balance recovery after a trip during walking. An orthopedic corset was used to simulate trunk stiffness in 11 young male adults. Subjects walked over a platform, with or without the corset on, and were occasionally tripped over a hidden obstacle. Kinematics of the tripping reaction were measured. Initial trunk accelerations were significantly attenuated by the corset, which indicates a positive effect of the stiffening corset. However, no subsequent effects on peak trunk inclination and on the peak moment arm of gravity on the trunk were found. The pattern of trunk motion allowed ample time for triggered or voluntary muscle responses to be generated, before a substantial inclination occurred. It appears that such active responses were sufficient in the young subjects tested to obtain a similar net effect with or without the increased trunk stiffness induced by the corset.

  12. On the stiffness analysis of a cable driven leg exoskeleton.

    PubMed

    Sanjeevi, N S S; Vashista, Vineet

    2017-07-01

    Robotic systems are being used for gait rehabilitation of patients with neurological disorder. These devices are externally powered to apply external forces on human limbs to assist the leg motion. Patients while walking with these devices adapt their walking pattern in response to the applied forces. The efficacy of a rehabilitation paradigm thus depends on the human-robot interaction. A cable driven leg exoskeleton (CDLE) use actuated cables to apply external joint torques on human leg. Cables are lightweight and flexible but can only be pulled, thus a CDLE requires redundant cables. Redundancy in CDLE can be utilized to appropriately tune a robot's performance. In this work, we present the stiffness analysis of CDLE. Different stiffness performance indices are established to study the role of system parameters in improving the human-robot interaction.

  13. Vertical stiffness is not related to anterior cruciate ligament elongation in professional rugby union players

    PubMed Central

    Serpell, Benjamin G; Scarvell, Jennie M; Pickering, Mark R; Ball, Nick B; Perriman, Diana; Warmenhoven, John; Smith, Paul N

    2016-01-01

    Background Novel research surrounding anterior cruciate ligament (ACL) injury is necessary because ACL injury rates have remained unchanged for several decades. An area of ACL risk mitigation which has not been well researched relates to vertical stiffness. The relationship between increased vertical stiffness and increased ground reaction force suggests that vertical stiffness may be related to ACL injury risk. However, given that increased dynamic knee joint stability has been shown to be associated with vertical stiffness, it is possible that modification of vertical stiffness could help to protect against injury. We aimed to determine whether vertical stiffness is related to measures known to load, or which represent loading of, the ACL. Methods This was a cross-sectional observational study of 11 professional Australian rugby players. Knee kinematics and ACL elongation were measured from a 4-dimensional model of a hopping task which simulated the change of direction manoeuvre typically observed when non-contact ACL injury occurs. The model was generated from a CT scan of the participant's knee registered frame by frame to fluoroscopy images of the hopping task. Vertical stiffness was calculated from force plate data. Results There was no association found between vertical stiffness and anterior tibial translation (ATT) or ACL elongation (r=−0.05; p=0.89, and r=−0.07; p=0.83, respectively). ATT was related to ACL elongation (r=0.93; p=0.0001). Conclusions Vertical stiffness was not associated with ACL loading in this cohort of elite rugby players but a novel method for measuring ACL elongation in vivo was found to have good construct validity. PMID:27900192

  14. A comparison and update of direct kinematic-kinetic models of leg stiffness in human running.

    PubMed

    Liew, Bernard X W; Morris, Susan; Masters, Ashleigh; Netto, Kevin

    2017-11-07

    Direct kinematic-kinetic modelling currently represents the "Gold-standard" in leg stiffness quantification during three-dimensional (3D) motion capture experiments. However, the medial-lateral components of ground reaction force and leg length have been neglected in current leg stiffness formulations. It is unknown if accounting for all 3D would alter healthy biologic estimates of leg stiffness, compared to present direct modelling methods. This study compared running leg stiffness derived from a new method (multiplanar method) which includes all three Cartesian axes, against current methods which either only include the vertical axis (line method) or only the plane of progression (uniplanar method). Twenty healthy female runners performed shod overground running at 5.0 m/s. Three-dimensional motion capture and synchronised in-ground force plates were used to track the change in length of the leg vector (hip joint centre to centre of pressure) and resultant projected ground reaction force. Leg stiffness was expressed as dimensionless units, as a percentage of an individual's bodyweight divided by standing leg length (BW/LL). Leg stiffness using the line method was larger than the uniplanar method by 15.6%BW/LL (P < .001), and multiplanar method by 24.2%BW/LL (P < .001). Leg stiffness from the uniplanar method was larger than the multiplanar method by 8.5%BW/LL (6.5 kN/m) (P < .001). The inclusion of medial-lateral components significantly increased leg deformation magnitude, accounting for the reduction in leg stiffness estimate with the multiplanar method. Given that limb movements typically occur in 3D, the new multiplanar method provides the most complete accounting of all force and length components in leg stiffness calculation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Regional variation in the mechanical properties of the vertebral column during lateral bending in Morone saxatilis

    PubMed Central

    Nowroozi, B. N.; Brainerd, E. L.

    2012-01-01

    Unlike mammalian, disc-shaped intervertebral joints (IVJs), the IVJs in fishes are biconid structures, filled with fluid and thought to act as hydrostatic hinge joints during swimming. However, it remains unclear which IVJ structures are dominant in mechanical resistance to forces in fishes, and whether variation in these tissues might impact the function of the vertebral column along its length. Here, we measured the dynamic mechanical behaviour of IVJs from striped bass, Morone saxatilis. During lateral bending, angular stiffness was significantly lower in the caudal and cervical regions, relative to the abdominal region. The neutral zone, defined as the range of motion (ROM) at bending moments less than 0.001 Nm, was longer in the caudal relative to the abdominal IVJs. Hysteresis was 30–40% in all regions, suggesting that IVJs may play a role in energy dissipation during swimming. Cutting the vertical septum had no statistically significant effect, but cutting the encapsulating tissues caused a sharp decline in angular stiffness and a substantial increase in ROM and hysteresis. We conclude that stiffness decreases and ROM increases from cranial to caudal in striped bass, and that the encapsulating tissues play a prominent role in mechanical variation along the length of the vertebral column. PMID:22552920

  16. Regional variation in the mechanical properties of the vertebral column during lateral bending in Morone saxatilis.

    PubMed

    Nowroozi, B N; Brainerd, E L

    2012-10-07

    Unlike mammalian, disc-shaped intervertebral joints (IVJs), the IVJs in fishes are biconid structures, filled with fluid and thought to act as hydrostatic hinge joints during swimming. However, it remains unclear which IVJ structures are dominant in mechanical resistance to forces in fishes, and whether variation in these tissues might impact the function of the vertebral column along its length. Here, we measured the dynamic mechanical behaviour of IVJs from striped bass, Morone saxatilis. During lateral bending, angular stiffness was significantly lower in the caudal and cervical regions, relative to the abdominal region. The neutral zone, defined as the range of motion (ROM) at bending moments less than 0.001 Nm, was longer in the caudal relative to the abdominal IVJs. Hysteresis was 30-40% in all regions, suggesting that IVJs may play a role in energy dissipation during swimming. Cutting the vertical septum had no statistically significant effect, but cutting the encapsulating tissues caused a sharp decline in angular stiffness and a substantial increase in ROM and hysteresis. We conclude that stiffness decreases and ROM increases from cranial to caudal in striped bass, and that the encapsulating tissues play a prominent role in mechanical variation along the length of the vertebral column.

  17. Probabilistic micromechanics of woven ceramic matrix composites

    NASA Astrophysics Data System (ADS)

    Goldsmith, Marlana

    Woven ceramic matrix composites are a special class of composite materials that are of current interest for harsh thermo-structural conditions such as those encountered by hypersonic vehicle systems and turbine engine components. Testing of the materials is expensive, especially as materials are constantly redesigned. Randomness in the tow architecture, as well as the randomly shaped and spaced voids that are produced as a result of the manufacturing process, are features that contribute to variability in stiffness and strength. The goal of the research is to lay a foundation in which characteristics of the geometry can be translated into material properties. The research first includes quantifying the architectural variability based on 2D micrographs of a 5 harness satin CVI (Chemical Vapor Infiltration) SiC/SiC composite. The architectural variability is applied to a 2D representative volume element (RVE) in order to evaluate which aspects of the architecture are important to model in order to capture the variability found in the cross sections. Tow width, tow spacing, and tow volume fraction were found to have some effect on the variability, but voids were found to have a large influence on transverse stiffness, and a separate study was conducted to determine which characteristics of the voids are most critical to model. It was found that the projected area of the void perpendicular to the transverse direction and the number of voids modeled had a significant influence on the stiffness. The effect of varying architecture on the variability of in-plane tensile strength was also studied using the Brittle Cracking Model for Concrete in the commercial finite element software, Abaqus. A maximum stress criterion is used to evaluate failure, and the stiffness of failed elements is gradually degraded such that the energy required to open a crack (fracture energy) is dissipated during this degradation process. While the varying architecture did not create variability in the in-plane stiffness, it does contribute significantly to the variability of in-plane strength as measured by a 0.02% offset method. Applying spatially random strengths for the constituents did not contribute to variability in strength as measured by the 0.02% offset. The results of this research may be of interest to those designing materials, as well as those using the material in their design. Having an idea about which characteristics of the architecture affect variability in stiffness may provide guidance to the material designer with respect to which aspects of the architecture can be controlled or improved to decrease the variability of the material properties. The work will also be useful to those desiring to use the complex materials by determining how to link the architectural properties to the mechanical properties with the ultimate goal of reducing the required number of tests.

  18. Crack Damage Parameters and Dilatancy of Artificially Jointed Granite Samples Under Triaxial Compression

    NASA Astrophysics Data System (ADS)

    Walton, G.; Alejano, L. R.; Arzua, J.; Markley, T.

    2018-06-01

    A database of post-peak triaxial test results was created for artificially jointed planes introduced in cylindrical compression samples of a Blanco Mera granite. Aside from examining the artificial jointing effect on major rock and rock mass parameters such as stiffness, peak strength and residual strength, other strength parameters related to brittle cracking and post-yield dilatancy were analyzed. Crack initiation and crack damage values for both the intact and artificially jointed samples were determined, and these damage envelopes were found to be notably impacted by the presence of jointing. The data suggest that with increased density of jointing, the samples transition from a combined matrix damage and joint slip yielding mechanism to yield dominated by joint slip. Additionally, post-yield dilation data were analyzed in the context of a mobilized dilation angle model, and the peak dilation angle was found to decrease significantly when there were joints in the samples. These dilatancy results are consistent with hypotheses in the literature on rock mass dilatancy.

  19. Biomechanical investigation of two plating systems for medial column fusion in foot

    PubMed Central

    Simons, Paul; Sommerer, Theresia; Zderic, Ivan; Wahl, Dieter; Lenz, Mark; Skulev, Hristo; Knobe, Matthias; Gueorguiev, Boyko; Richards, R. Geoff; Klos, Kajetan

    2017-01-01

    Background Arthrodesis of the medial column (navicular, cuneiform I and metatarsal I) is performed for reasons such as Charcot arthropathy, arthritis, posttraumatic reconstruction or severe pes planus. However, the complication rate is still high and mainly resulting from inadequate fixation. Special plates, designed for medial column arthrodesis, seem to offer potential to reduce the complication rate. The aim of this study was to investigate biomechanically plantar and dorsomedial fusion of the medial column using two new plating systems. Methods Eight matched pairs of human cadaveric lower legs were randomized in two groups and medial column fusion was performed using either plantar or dorsomedial variable-angle locking compression plates. The specimens were biomechanically tested under cyclic progressively increasing axial loading with physiological profile of each cycle. In addition to the machine data, mediolateral x-rays were taken every 250 cycles and motion tracking was performed to determine movements at the arthrodesis site. Statistical analysis of the parameters of interest was performed at a level of significance p = 0.05. Results Displacement of the talo-navicular joint after 1000, 2000 and 4000 cycles was significantly lower for plantar plating (p≤0.039) while there was significantly less movement in the naviculo-cuneiform I joint for dorsal plating post these cycle numbers (p<0.001). Displacements in all three joints of the medial column, as well as angular and torsional deformations between the navicular and metatarsal I increased significantly for each plating technique between 1000, 2000 and 4000 cycles (p≤0.021). The two plating systems did not differ significantly with regard to stiffness and cycles to failure (p≥0.171). Conclusion From biomechanical point of view, although dorsomedial plating showed less movement than plantar plating in the current setup under dynamic loading, there was no significant difference between the two plating systems with regard to stiffness and cycles to failure. Both tested techniques for dorsomedial and plantar plating appear to be applicable for arthrodesis of the medial column of the foot and other considerations, such as access morbidity, associated deformities or surgeon's preference, may also guide the choice of plating pattern. Further clinical studies are necessary before definitive recommendations can be given. PMID:28222170

  20. Biomechanical investigation of two plating systems for medial column fusion in foot.

    PubMed

    Simons, Paul; Sommerer, Theresia; Zderic, Ivan; Wahl, Dieter; Lenz, Mark; Skulev, Hristo; Knobe, Matthias; Gueorguiev, Boyko; Richards, R Geoff; Klos, Kajetan

    2017-01-01

    Arthrodesis of the medial column (navicular, cuneiform I and metatarsal I) is performed for reasons such as Charcot arthropathy, arthritis, posttraumatic reconstruction or severe pes planus. However, the complication rate is still high and mainly resulting from inadequate fixation. Special plates, designed for medial column arthrodesis, seem to offer potential to reduce the complication rate. The aim of this study was to investigate biomechanically plantar and dorsomedial fusion of the medial column using two new plating systems. Eight matched pairs of human cadaveric lower legs were randomized in two groups and medial column fusion was performed using either plantar or dorsomedial variable-angle locking compression plates. The specimens were biomechanically tested under cyclic progressively increasing axial loading with physiological profile of each cycle. In addition to the machine data, mediolateral x-rays were taken every 250 cycles and motion tracking was performed to determine movements at the arthrodesis site. Statistical analysis of the parameters of interest was performed at a level of significance p = 0.05. Displacement of the talo-navicular joint after 1000, 2000 and 4000 cycles was significantly lower for plantar plating (p≤0.039) while there was significantly less movement in the naviculo-cuneiform I joint for dorsal plating post these cycle numbers (p<0.001). Displacements in all three joints of the medial column, as well as angular and torsional deformations between the navicular and metatarsal I increased significantly for each plating technique between 1000, 2000 and 4000 cycles (p≤0.021). The two plating systems did not differ significantly with regard to stiffness and cycles to failure (p≥0.171). From biomechanical point of view, although dorsomedial plating showed less movement than plantar plating in the current setup under dynamic loading, there was no significant difference between the two plating systems with regard to stiffness and cycles to failure. Both tested techniques for dorsomedial and plantar plating appear to be applicable for arthrodesis of the medial column of the foot and other considerations, such as access morbidity, associated deformities or surgeon's preference, may also guide the choice of plating pattern. Further clinical studies are necessary before definitive recommendations can be given.

  1. Seismic Response Control Of Structures Using Semi-Active and Passive Variable Stiffness Devices

    NASA Astrophysics Data System (ADS)

    Salem, Mohamed M. A.

    Controllable devices such as Magneto-Rheological Fluid Dampers, Electro-Rheological Dampers, and controllable friction devices have been studied extensively with limited implementation in real structures. Such devices have shown great potential in reducing seismic demands, either as smart base isolation systems, or as smart devices for multistory structures. Although variable stiffness devices can be used for seismic control of structures, the vast majority of research effort has been given to the control of damping. The primary focus of this dissertation is to evaluate the seismic control of structures using semi-active and passive variable stiffness characteristics. Smart base isolation systems employing variable stiffness devices have been studied, and two semi-active control strategies are proposed. The control algorithms were designed to reduce the superstructure and base accelerations of seismically isolated structures subject to near-fault and far-field ground motions. Computational simulations of the proposed control algorithms on the benchmark structure have shown that excessive base displacements associated with the near-fault ground motions may be better mitigated with the use of variable stiffness devices. However, the device properties must be controllable to produce a wide range of stiffness changes for an effective control of the base displacements. The potential of controllable stiffness devices in limiting the base displacement due to near-fault excitation without compromising the performance of conventionally isolated structures, is illustrated. The application of passive variable stiffness devices for seismic response mitigation of multistory structures is also investigated. A stiffening bracing system (SBS) is proposed to replace the conventional bracing systems of braced frames. An optimization process for the SBS parameters has been developed. The main objective of the design process is to maintain a uniform inter-story drift angle over the building's height, which in turn would evenly distribute the seismic demand over the building. This behavior is particularly essential so that any possible damage is not concentrated in a single story. Furthermore, the proposed design ensures that additional damping devices distributed over the building's height work efficiently with their maximum design capacity, leading to a cost efficient design. An integrated and comprehensive design procedure that can be readily adopted by the current seismic design codes is proposed. An equivalent lateral force distribution is developed that shows a good agreement with the response history analyses in terms of seismic performance and demand prediction. This lateral force pattern explicitly accounts for the higher mode effect, the dynamic characteristics of the structure, the supplemental damping, and the site specific seismic hazard. Therefore, the proposed design procedure is considered as a standalone method for the design of SBS equipped buildings.

  2. Inspiration from nature: dynamic modelling of the musculoskeletal structure of the seahorse tail.

    PubMed

    Praet, Tomas; Adriaens, Dominique; Van Cauter, Sofie; Masschaele, Bert; De Beule, Matthieu; Verhegghe, Benedict

    2012-10-01

    Technological advances are often inspired by nature, considering that engineering is frequently faced by the same challenges as organisms in nature. One such interesting challenge is creating a structure that is at the same time stiff in a certain direction, yet flexible in another. The seahorse tail combines both radial stiffness and bending flexibility in a particularly elegant way: even though the tail is covered in a protective armour, it still shows sufficient flexibility to fully function as a prehensile organ. We therefore study the complex mechanics and dynamics of the musculoskeletal system of the seahorse tail from an engineering point of view. The seahorse tail derives its combination of flexibility and resilience from a chain of articulating skeletal segments. A versatile dynamic model of those segments was constructed, on the basis of automatic recognition of joint positions and muscle attachments. Both muscle structures that are thought to be responsible for ventral and ventral-lateral tail bending, namely the median ventral muscles and the hypaxial myomere muscles, were included in the model. Simulations on the model consist mainly of dynamic multi-body simulations. The results show that the sequential structure of uniformly shaped bony segments can remain flexible because of gliding joints that connect the corners of the segments. Radial stiffness on the other hand is obtained through the support that the central vertebra provides to the tail plating. Such insights could help in designing biomedical instruments that specifically require both high bending flexibility and radial stiffness (e.g. flexible stents and steerable catheters). Copyright © 2012 John Wiley & Sons, Ltd.

  3. Assessing the Relative Contributions of Active Ankle and Knee Assistance to the Walking Mechanics of Transfemoral Amputees Using a Powered Prosthesis

    PubMed Central

    Simon, Ann M.; Hargrove, Levi J.

    2016-01-01

    Powered knee-ankle prostheses are capable of providing net-positive mechanical energy to amputees. Yet, there are limitless ways to deliver this energy throughout the gait cycle. It remains largely unknown how different combinations of active knee and ankle assistance affect the walking mechanics of transfemoral amputees. This study assessed the relative contributions of stance phase knee swing initiation, increasing ankle stiffness and powered plantarflexion as three unilateral transfemoral amputees walked overground at their self-selected walking speed. Five combinations of knee and ankle conditions were evaluated regarding the kinematics and kinetics of the amputated and intact legs using repeated measures analyses of variance. We found eliminating active knee swing initiation or powered plantarflexion was linked to increased compensations of the ipsilateral hip joint during the subsequent swing phase. The elimination of knee swing initiation or powered plantarflexion also led to reduced braking ground reaction forces of the amputated and intact legs, and influenced both sagittal and frontal plane loading of the intact knee joint. Gradually increasing prosthetic ankle stiffness influenced the shape of the prosthetic ankle plantarflexion moment, more closely mirroring the intact ankle moment. Increasing ankle stiffness also corresponded to increased prosthetic ankle power generation (despite a similar maximum stiffness value across conditions) and increased braking ground reaction forces of the amputated leg. These findings further our understanding of how to deliver assistance with powered knee-ankle prostheses and the compensations that occur when specific aspects of assistance are added/removed. PMID:26807889

  4. On the Value of Estimating Human Arm Stiffness during Virtual Teleoperation with Robotic Manipulators

    PubMed Central

    Buzzi, Jacopo; Ferrigno, Giancarlo; Jansma, Joost M.; De Momi, Elena

    2017-01-01

    Teleoperated robotic systems are widely spreading in multiple different fields, from hazardous environments exploration to surgery. In teleoperation, users directly manipulate a master device to achieve task execution at the slave robot side; this interaction is fundamental to guarantee both system stability and task execution performance. In this work, we propose a non-disruptive method to study the arm endpoint stiffness. We evaluate how users exploit the kinetic redundancy of the arm to achieve stability and precision during the execution of different tasks with different master devices. Four users were asked to perform two planar trajectories following virtual tasks using both a serial and a parallel link master device. Users' arm kinematics and muscular activation were acquired and combined with a user-specific musculoskeletal model to estimate the joint stiffness. Using the arm kinematic Jacobian, the arm end-point stiffness was derived. The proposed non-disruptive method is capable of estimating the arm endpoint stiffness during the execution of virtual teleoperated tasks. The obtained results are in accordance with the existing literature in human motor control and show, throughout the tested trajectory, a modulation of the arm endpoint stiffness that is affected by task characteristics and hand speed and acceleration. PMID:29018319

  5. Composite sizing and ply orientation for stiffness requirements using a large finite element structural model

    NASA Technical Reports Server (NTRS)

    Radovcich, N. A.; Gentile, D. P.

    1989-01-01

    A NASTRAN bulk dataset preprocessor was developed to facilitate the integration of filamentary composite laminate properties into composite structural resizing for stiffness requirements. The NASCOMP system generates delta stiffness and delta mass matrices for input to the flutter derivative program. The flutter baseline analysis, derivative calculations, and stiffness and mass matrix updates are controlled by engineer defined processes under an operating system called CBUS. A multi-layered design variable grid system permits high fidelity resizing without excessive computer cost. The NASCOMP system uses ply layup drawings for basic input. The aeroelastic resizing for stiffness capability was used during an actual design exercise.

  6. [Distal soft-tissue procedure in hallux valgus deformity].

    PubMed

    Arbab, D; Wingenfeld, C; Frank, D; Bouillon, B; König, D P

    2016-04-01

    Distal, lateral soft tissue release to restore mediolateral balance of the first metatarsophalangeal (MTP) joint in hallux valgus deformity. Incision of the adductor hallucis tendon from the fibular sesamoid, the lateral capsule, the lateral collateral ligament, and the lateral metatarsosesamoid ligament. Hallux valgus deformities or recurrent hallux valgus deformities with an incongruent MTP joint. General medical contraindications to surgical interventions. Painful stiffness of the MTP joint, osteonecrosis, congruent joint. Relative contraindications: connective tissue diseases (Marfan syndrome, Ehler-Danlos syndrome). Longitudinal, dorsal incision in the first intermetatarsal web space between the first and second MTP joint. Blunt dissection and identification of the adductor hallucis tendon. Release of the adductor tendon from the fibular sesamoid. Incision of the lateral capsule, the lateral collateral ligament, and the lateral metatarsosesamoid ligament. Postoperative management depends on bony correction. In joint-preserving procedures, dressing for 3 weeks in corrected position. Subsequently hallux valgus orthosis at night and a toe spreader for a further 3 months. Passive mobilization of the first MTP joint. Postoperative weight-bearing according to the osteotomy. A total of 31 patients with isolated hallux valgus deformity underwent surgery with a Chevron and Akin osteotomy and a distal medial and lateral soft tissue balancing. The mean preoperative intermetatarsal (IMA) angle was 12.3° (range 11-15°); the hallux valgus (HV) angle was 28.2° (25-36°). The mean follow-up was 16.4 months (range 12-22 months). The mean postoperative IMA correction ranged between 2 and 7° (mean 5.2°); the mean HV correction was 15.5° (range 9-21°). In all, 29 patients (93%) were satisfied or very satisfied with the postoperative outcome, while 2 patients (7%) were not satisfied due to one delayed wound healing and one recurrent hallux valgus deformity. There were no infections, clinical and radiological signs of avascular necrosis of the metatarsal head, overcorrection with hallux varus deformity, or significant stiffness of the first MTP joint.

  7. Morphological Computation of Haptic Perception of a Controllable Stiffness Probe.

    PubMed

    Sornkarn, Nantachai; Dasgupta, Prokar; Nanayakkara, Thrishantha

    2016-01-01

    When people are asked to palpate a novel soft object to discern its physical properties such as texture, elasticity, and even non-homogeneity, they not only regulate probing behaviors, but also the co-contraction level of antagonistic muscles to control the mechanical impedance of fingers. It is suspected that such behavior tries to enhance haptic perception by regulating the function of mechanoreceptors at different depths of the fingertips and proprioceptive sensors such as tendon and spindle sensors located in muscles. In this paper, we designed and fabricated a novel two-degree of freedom variable stiffness indentation probe to investigate whether the regulation of internal stiffness, indentation, and probe sweeping velocity (PSV) variables affect the accuracy of the depth estimation of stiff inclusions in an artificial silicon phantom using information gain metrics. Our experimental results provide new insights into not only the biological phenomena of haptic perception but also new opportunities to design and control soft robotic probes.

  8. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness.

    PubMed

    Freeberg, M J; Stone, M A; Triolo, R J; Tyler, D J

    2017-06-01

    As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite's capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. In vitro inflation tests showed effective CNRs (1.93  ±  0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p  >  0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p  >  0.14 for all measures). We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.

  9. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness

    NASA Astrophysics Data System (ADS)

    Freeberg, M. J.; Stone, M. A.; Triolo, R. J.; Tyler, D. J.

    2017-06-01

    Objective. As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Approach. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite’s capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. Main Results. In vitro inflation tests showed effective CNRs (1.93  ±  0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p  >  0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p  >  0.14 for all measures). Significance. We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.

  10. Design of a Variable Stiffness Soft Dexterous Gripper

    PubMed Central

    Nefti-Meziani, Samia; Davis, Steve

    2017-01-01

    Abstract This article presents the design of a variable stiffness, soft, three-fingered dexterous gripper. The gripper uses two designs of McKibben muscles. Extensor muscles that increase in length when pressurized are used to form the fingers of the gripper. Contractor muscles that decrease in length when pressurized are then used to apply forces to the fingers through tendons, which cause flexion and extension of the fingers. The two types of muscles are arranged to act antagonistically and this means that by raising the pressure in all of the pneumatic muscles, the stiffness of the system can be increased without a resulting change in finger position. The article presents the design of the gripper, some basic kinematics to describe its function, and then experimental results demonstrating the ability to adjust the bending stiffness of the gripper's fingers. It has been demonstrated that the fingers' bending stiffness can be increased by more than 150%. The article concludes by demonstrating that the fingers can be closed loop position controlled and are able to track step and sinusoidal inputs. PMID:29062630

  11. Adjustments with running speed reveal neuromuscular adaptations during landing associated with high mileage running training.

    PubMed

    Verheul, Jasper; Clansey, Adam C; Lake, Mark J

    2017-03-01

    It remains to be determined whether running training influences the amplitude of lower limb muscle activations before and during the first half of stance and whether such changes are associated with joint stiffness regulation and usage of stored energy from tendons. Therefore, the aim of this study was to investigate neuromuscular and movement adaptations before and during landing in response to running training across a range of speeds. Two groups of high mileage (HM; >45 km/wk, n = 13) and low mileage (LM; <15 km/wk, n = 13) runners ran at four speeds (2.5-5.5 m/s) while lower limb mechanics and electromyography of the thigh muscles were collected. There were few differences in prelanding activation levels, but HM runners displayed lower activations of the rectus femoris, vastus medialis, and semitendinosus muscles postlanding, and these differences increased with running speed. HM runners also demonstrated higher initial knee stiffness during the impact phase compared with LM runners, which was associated with an earlier peak knee flexion velocity, and both were relatively unchanged by running speed. In contrast, LM runners had higher knee stiffness during the slightly later weight acceptance phase and the disparity was amplified with increases in speed. It was concluded that initial knee joint stiffness might predominantly be governed by tendon stiffness rather than muscular activations before landing. Estimated elastic work about the ankle was found to be higher in the HM runners, which might play a role in reducing weight acceptance phase muscle activation levels and improve muscle activation efficiency with running training. NEW & NOTEWORTHY Although neuromuscular factors play a key role during running, the influence of high mileage training on neuromuscular function has been poorly studied, especially in relation to running speed. This study is the first to demonstrate changes in neuromuscular conditioning with high mileage training, mainly characterized by lower thigh muscle activation after touch down, higher initial knee stiffness, and greater estimates of energy return, with adaptations being increasingly evident at faster running speeds. Copyright © 2017 the American Physiological Society.

  12. Exercise through Menopause.

    ERIC Educational Resources Information Center

    Stuhr, Robyn M.

    2002-01-01

    Menopause is associated with many different health effects and symptoms. This paper explains that regular exercise can play a critical role in protecting health and battling the increased risk of cardiovascular disease, osteoporosis, pelvic floor atrophy, and joint stiffness associated with menopause. Exercise programs for menopausal women should…

  13. Multi-stability and variable stiffness of cellular solids designed based on origami patterns

    NASA Astrophysics Data System (ADS)

    Sengupta, Sattam; Li, Suyi

    2017-04-01

    The application of origami-inspired designs to engineered structures and materials has been a subject of much research efforts. These structures and materials, whose mechanical properties are directly related to the geometry of folding, are capable of achieving a host of unique adaptive functions. In this study, we investigate a three-dimensional multistability and variable stiffness function of a cellular solid based on the Miura-Ori folding pattern. The unit cell of such a solid, consisting of two stacked Miura-Ori sheets, can be elastically bistable due to the nonlinear relationship between rigid-folding deformation and crease material bending. Such a bistability possesses an unorthodox property: the critical, unstable configuration lies on the same side of two stable ones, so that two different force-deformation curves co-exist within the same range of deformation. By exploiting such unique stability properties, we can achieve a programmable stiffness change between the two elastically stable states, and the stiffness differences can be prescribed by tailoring the crease patterns of the cell. This paper presents a comprehensive parametric study revealing the correlations between such variable stiffness and various design parameters. The unique properties stemming from the bistability and design of such a unit cell can be advanced further by assembling them into a solid which can be capable of shape morphing and programmable mechanical properties.

  14. Variable stiffness torsion springs

    NASA Astrophysics Data System (ADS)

    Alhorn, Dean C.; Polites, Michael E.

    1994-05-01

    In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.

  15. Variable stiffness torsion springs

    NASA Technical Reports Server (NTRS)

    Alhorn, Dean C. (Inventor); Polites, Michael E. (Inventor)

    1995-01-01

    In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.

  16. Variable stiffness torsion springs

    NASA Astrophysics Data System (ADS)

    Alhorn, Dean C.; Polites, Michael E.

    1995-08-01

    In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.

  17. Variable stiffness torsion springs

    NASA Technical Reports Server (NTRS)

    Alhorn, Dean C. (Inventor); Polites, Michael E. (Inventor)

    1994-01-01

    In a torsion spring the spring action is a result of the relationships between the torque applied in twisting the spring, the angle through which the torsion spring twists, and the modulus of elasticity of the spring material in shear. Torsion springs employed industrially have been strips, rods, or bars, generally termed shafts, capabable of being flexed by twisting their axes. They rely on the variations in shearing forces to furnish an internal restoring torque. In the torsion springs herein the restoring torque is external and therefore independent of the shearing modulus of elasticity of the torsion spring shaft. Also provided herein is a variable stiffness torsion spring. This torsion spring can be so adjusted as to have a given spring constant. Such variable stiffness torsion springs are extremely useful in gimballed payloads such as sensors, telescopes, and electronic devices on such platforms as a space shuttle or a space station.

  18. Long term type 1 diabetes is associated with hand pain, disability and stiffness but not with structural hand osteoarthritis features – The Dialong hand study

    PubMed Central

    Magnusson, Karin; Bech Holte, Kristine; Juel, Niels Gunnar; Brox, Jens Ivar; Hagen, Kåre Birger; Haugen, Ida Kristin; Berg, Tore Julsrud

    2017-01-01

    Objective To explore whether having long-term type 1 diabetes (>45 years) is associated with a higher prevalence of radiographic hand OA, erosive hand OA and increased hand pain, disability and stiffness. Methods In total N = 96 persons with type 1 diabetes diagnosed before 1970 were included (mean [SD] age: 62.2 [7.4], mean [SD] HbA1c: 7.43 [0.80] and N = 49 [51%] men). Regular measurements of their HbA1c were obtained till 2015. We included N = 69 healthy controls without any diabetes (mean [SD] age: 63.0 [7.0], mean [SD] HbA1c: 5.41 [0.32], N = 29 [42%] men). The groups were compared for radiographic hand OA (Kellgren-Lawrence grade ≥2 in ≥1 joint) and erosive hand OA (central erosions in ≥1 joint), Australian/Canadian index (AUSCAN) for hand pain, disability and stiffness using regression analyses adjusted for age, sex, educational level and waist circumference. Results We found no associations between having long term type 1 diabetes and more prevalent radiographic hand OA (OR = 0.83, 95% CI = 0.38–1.81). We found a trend towards higher prevalence of erosive hand OA in diabetes patients (OR = 2.96, 95% CI = 0.82–10.64). Strong and consistent associations were observed between long term type 1 diabetes and increased hand pain (B = 2.78, 95% CI = 1.65–3.91), disability (B = 5.30, 95% CI = 3.48–7.12) and stiffness (B = 2.00, 95% CI = 1.33–2.67). These associations were particularly strong for women and participants below the median age of 61 years. Conclusion Long-term type 1 diabetes was not associated with radiographic hand OA, but was strongly associated with hand pain, disability and stiffness. The association between diabetes and erosive hand OA warrants further investigation. PMID:28510594

  19. A springy pendulum could describe the swing leg kinetics of human walking.

    PubMed

    Song, Hyunggwi; Park, Heewon; Park, Sukyung

    2016-06-14

    The dynamics of human walking during various walking conditions could be qualitatively captured by the springy legged dynamics, which have been used as a theoretical framework for bipedal robotics applications. However, the spring-loaded inverted pendulum model describes the motion of the center of mass (CoM), which combines the torso, swing and stance legs together and does not explicitly inform us as to whether the inter-limb dynamics share the springy legged dynamics characteristics of the CoM. In this study, we examined whether the swing leg dynamics could also be represented by springy mechanics and whether the swing leg stiffness shows a dependence on gait speed, as has been observed in CoM mechanics during walking. The swing leg was modeled as a spring-loaded pendulum hinged at the hip joint, which is under forward motion. The model parameters of the loaded mass were adopted from body parameters and anthropometric tables, whereas the free model parameters for the rest length of the spring and its stiffness were estimated to best match the data for the swing leg joint forces. The joint forces of the swing leg were well represented by the springy pendulum model at various walking speeds with a regression coefficient of R(2)>0.8. The swing leg stiffness increased with walking speed and was correlated with the swing frequency, which is consistent with previous observations from CoM dynamics described using the compliant leg. These results suggest that the swing leg also shares the springy dynamics, and the compliant walking model could be extended to better present swing leg dynamics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Association between use of self-prescribed complementary and alternative medicine and menopause-related symptoms: a cross-sectional study.

    PubMed

    Peng, Wenbo; Sibbritt, David W; Hickman, Louise; Adams, Jon

    2015-10-01

    To examine the association between self-prescribed complementary and alternative medicine use and menopause-related symptoms, stratified by menopausal status. Data were obtained from a cross-sectional survey of a nationally representative sample of 10,011 menopausal women from the Australian Longitudinal Study on Women's Health, conducted in 2010. Multivariable logistic regression models were applied to identify if the use of selected self-prescribed complementary and alternative medicine was significantly associated with a range of menopause-related symptoms. Vitamins/minerals were more likely to be used by natural menopausal women experiencing anxiety (adjusted OR=1.20) and/or stiff/painful joints (adjusted OR=1.16). Yoga/meditation was more likely to be used by women with hysterectomy (adjusted OR=1.76) or natural menopausal women (adjusted OR=1.38) experiencing anxiety. Herbal medicines were more likely to be used by natural menopausal women experiencing anxiety (adjusted OR=1.22), tiredness (adjusted OR=1.20), and/or stiff/painful joints (adjusted OR=1.17), and by women with oophorectomy experiencing tiredness (adjusted OR=1.45). Aromatherapy oils were more likely to be used by natural menopausal women experiencing night sweats (adjusted OR=1.25) and by women with hysterectomy experiencing anxiety (adjusted OR=2.02). Chinese medicines were more likely to be used by women with oophorectomy experiencing stiff/painful joints (adjusted OR=4.06) and/or palpitations (adjusted OR=3.06). Our study will help improve the patient-provider communication regarding complementary and alternative medicine use for menopause, and we conclude that menopausal status should be taken into account by providers for menopause care. The women's experience and motivations of such use warrant further research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. A painless and constraint-free method to estimate viscoelastic passive dynamics of limbs' joints to support diagnosis of neuromuscular diseases.

    PubMed

    Venture, Gentiane; Nakamura, Yoshihiko; Yamane, Katsu; Hirashima, Masaya

    2007-01-01

    Though seldom identified, the human joints dynamics is important in the fields of medical robotics and medical research. We present a general solution to estimate in-vivo and simultaneously the passive dynamics of the human limbs' joints. It is based on the use of the multi-body description of the human body and its kinematics and dynamics computations. The linear passive joint dynamics of the shoulders and the elbows: stiffness, viscosity and friction, is estimated simultaneously using the linear least squares method. Acquisition of movements is achieved with an optical motion capture studio on one examinee during the clinical diagnosis of neuromuscular diseases. Experimental results are given and discussed.

  2. Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Data report

    NASA Technical Reports Server (NTRS)

    Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.

    1982-01-01

    Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116 K (-250 F), 294 K (70 F) and 561 K (550 F). Joint parameters evaluated are lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Advanced joint concepts were examined to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. The material properties of the high temperature adhesive, designated A7F, used for bonding were established. The bonded joint tests resulted in interlaminar shear or peel failures of the composite and there were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.

  3. Interfacial contact stiffness of fractal rough surfaces.

    PubMed

    Zhang, Dayi; Xia, Ying; Scarpa, Fabrizio; Hong, Jie; Ma, Yanhong

    2017-10-09

    In this work we describe a theoretical model that predicts the interfacial contact stiffness of fractal rough surfaces by considering the effects of elastic and plastic deformations of the fractal asperities. We also develop an original test rig that simulates dovetail joints for turbo machinery blades, which can fine tune the normal contact load existing between the contacting surfaces of the blade root. The interfacial contact stiffness is obtained through an inverse identification method in which finite element simulations are fitted to the experimental results. Excellent agreement is observed between the contact stiffness predicted by the theoretical model and by the analogous experimental results. We demonstrate that the contact stiffness is a power law function of the normal contact load with an exponent α within the whole range of fractal dimension D(1 < D < 2). We also show that for 1 < D < 1.5 the Pohrt-Popov behavior (α = 1/(3 - D)) is valid, however for 1.5 < D < 2, the exponent α is different and equal to 2(D - 1)/D. The diversity between the model developed in the work and the Pohrt-Popov one is explained in detail.

  4. Predictive Behavior of a Computational Foot/Ankle Model through Artificial Neural Networks.

    PubMed

    Chande, Ruchi D; Hargraves, Rosalyn Hobson; Ortiz-Robinson, Norma; Wayne, Jennifer S

    2017-01-01

    Computational models are useful tools to study the biomechanics of human joints. Their predictive performance is heavily dependent on bony anatomy and soft tissue properties. Imaging data provides anatomical requirements while approximate tissue properties are implemented from literature data, when available. We sought to improve the predictive capability of a computational foot/ankle model by optimizing its ligament stiffness inputs using feedforward and radial basis function neural networks. While the former demonstrated better performance than the latter per mean square error, both networks provided reasonable stiffness predictions for implementation into the computational model.

  5. A quantitative method for evaluating inferior glenohumeral joint stiffness using ultrasonography.

    PubMed

    Tsai, Wen-Wei; Lee, Ming-Yih; Yeh, Wen-Lin; Cheng, Shih-Chung; Soon, Kok-Soon; Lei, Kin Fong; Lin, Wen-Yen

    2013-02-01

    Subluxation of the affected shoulder in post-stroke patients is associated with nerve disorders and muscle fatigue. Clinicians must be able to accurately and reliably measure inferior glenohumeral subluxation in patients to provide appropriate treatment. However, quantitative methods for evaluating the laxity and stiffness of the glenohumeral joint (GHJ) are still being developed. The aim of this study was to develop a new protocol for evaluating the laxity and stiffness of the inferior GHJ using ultrasonography under optimal testing conditions and to investigate changes in the GHJ from a commercially available humerus brace and shoulder brace. Multistage inferior displacement forces were applied to create a glide between the most cephalad point on the visible anterosuperior surface of the humeral head and coracoid process in seven healthy volunteers. GHJ stiffness was defined as the slope of the linear regression line between the glides and different testing loads. The testing conditions were defined by different test loading mechanisms (n=2), shoulder constraining conditions (n=2), and loading modes (n=4). The optimal testing condition was defined as the condition with the least residual variance of measured laxity to the calculated stiffness under different testing loads. A paired t-test was used to compare the laxity and stiffness of the inferior GHJ using different braces. No significant difference was identified between the two test loading mechanisms (t=0.218, p=0.831) and two shoulder constraining conditions (t=-0.235, p=0.818). We concluded that ultrasonographic laxity measurements performed using a pulley set loading mechanism was as reliable as direct loading. Additionally, constraining the unloaded shoulder was proposed due to the lower mean residual variance value. Moreover, pulling the elbow downward with loading on the upper arm was suggested, as pulling the elbow downward with the elbow flexed and loading on the forearm may overestimate stiffness and pain in the inferior GHJ at the loading point due to friction between the wide belt and skin. Furthermore, subjects wearing a humerus brace with a belt, which creates the effect of lifting the humerus toward the acromion, had greater GHJ stiffness compared to subjects wearing a shoulder brace without a belt to lift the humerus under the proposed testing conditions. This study provides experimental evidence that shoulder braces may reduce GHJ laxity under an external load, implying that the use of a humeral brace can prevent subluxation in post-stroke patients. The resulting optimal testing conditions for measuring the laxity and stiffness of the GHJ is to constrain the unloaded shoulder and bend the loaded arm at the elbow with loading on the upper arm using a pulley system. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. A Biomechanical Simulation of the Effect of the Extrinsic Flexor Muscles on Finger Joint Flexion

    DTIC Science & Technology

    2001-10-25

    vol. 44, pp. 493-504, 1997. [8] A.B. Leger and T.E. Milner, “The effect of eccentric exercise on intrinsic and reflex stiffness in the human hand...line of action of the tendons and the effective moment arms. After a certain point, the FDP tendon became slack, while the FDS tendon remained...link chain with three revolute joints and four links was created to model the index finger. The tendons from the extrinsic flexor muscles were

  7. Large strain variable stiffness composites for shear deformations with applications to morphing aircraft skins

    NASA Astrophysics Data System (ADS)

    McKnight, G. P.; Henry, C. P.

    2008-03-01

    Morphing or reconfigurable structures potentially allow for previously unattainable vehicle performance by permitting several optimized structures to be achieved using a single platform. The key to enabling this technology in applications such as aircraft wings, nozzles, and control surfaces, are new engineered materials which can achieve the necessary deformations but limit losses in parasitic actuation mass and structural efficiency (stiffness/weight). These materials should exhibit precise control of deformation properties and provide high stiffness when exercised through large deformations. In this work, we build upon previous efforts in segmented reinforcement variable stiffness composites employing shape memory polymers to create prototype hybrid composite materials that combine the benefits of cellular materials with those of discontinuous reinforcement composites. These composites help overcome two key challenges for shearing wing skins: the resistance to out of plane buckling from actuation induced shear deformation, and resistance to membrane deflections resulting from distributed aerodynamic pressure loading. We designed, fabricated, and tested composite materials intended for shear deformation and address out of plane deflections in variable area wing skins. Our designs are based on the kinematic engineering of reinforcement platelets such that desired microstructural kinematics is achieved through prescribed boundary conditions. We achieve this kinematic control by etching sheets of metallic reinforcement into regular patterns of platelets and connecting ligaments. This kinematic engineering allows optimization of materials properties for a known deformation pathway. We use mechanical analysis and full field photogrammetry to relate local scale kinematics and strains to global deformations for both axial tension loading and shear loading with a pinned-diamond type fixture. The Poisson ratio of the kinematically engineered composite is ~3x higher than prototypical orthotropic variable stiffness composites. This design allows us to create composite materials that have high stiffness in the cold state below SMP T g (4-14GPa) and yet achieve large composite shear strains (5-20%) in the hot state (above SMP T g).

  8. Juvenile hyaline fibromatosis: a case report and review of literature.

    PubMed

    Ribeiro, Sandra Lúcia; Guedes, Erilane L; Botan, Valeria; Barbosa, Alessandra; Freitas, Ernani J

    2009-01-01

    Juvenile hyaline fibromatosis (JHF) is a rare disease with autosomal recessive inheritance that occurs mainly in childhood and is characterized by the deposition of amorphous hyaline material in the skin and other organs. There are approximately 70 cases reported in the literature. Herein we describe the case of a 14-month-old boy with multiple cutaneous nodules around small and large joints, papulous skin lesions, hyperpigmented plaques and nodules in the perianal region, flexion contractures and stiffness of joints and diffuse osteoporosis. Symptoms were present since the second month of life. Histopathologic studies of joint nodulations demonstrated the presence of hyaline material, confirming the diagnosis of juvenile hyaline fibromatosis.

  9. Variable Cadence Walking and Ground Adaptive Standing with a Powered Ankle Prosthesis

    PubMed Central

    Shultz, Amanda H.; Lawson, Brian E.; Goldfarb, Michael

    2015-01-01

    Abstract This paper describes a control approach that provides walking and standing functionality for a powered ankle prosthesis, and demonstrates the efficacy of the approach in experiments in which a unilateral transtibial amputee subject walks with the prosthesis at variable cadences, and stands on various slopes. Both controllers incorporate a finite-state structure that emulates healthy ankle joint behavior via a series of piecewise passive impedance functions. The walking controller incorporates an algorithm to modify impedance parameters based on estimated cadence, while the standing controller incorporates an algorithm to modulate the ankle equilibrium angle in order to adapt to the ground slope and user posture, and the supervisory controller selects between the walking and standing controllers. The system is shown to reproduce several essential biomechanical features of the healthy joint during walking, particularly relative to a passive prosthesis, and is shown to adapt to variable cadences. The system is also shown to adapt to slopes over a range of ± 15 deg and to provide support to the user in a manner that is biomimetic, as validated by quasi-static stiffness measurements recorded by the prosthesis. Data from standing trials indicate that the user places more weight on the powered prosthesis than on his passive prosthesis when standing on sloped surfaces, particularly at angles of 10 deg or greater. The authors also demonstrated that the prosthesis typically began providing support within 1 s of initial contact with the ground. Further, the supervisory controller was shown to be effective in switching between walking and standing, as well as in determining ground slope just prior to the transition from the standing controller to the walking controller, where the estimated ground slope was within 1.25 deg of the actual ground slope for all trials. PMID:25955789

  10. Energy Finite Element Analysis for Computing the High Frequency Vibration of the Aluminum Testbed Cylinder and Correlating the Results to Test Data

    NASA Technical Reports Server (NTRS)

    Vlahopoulos, Nickolas

    2005-01-01

    The Energy Finite Element Analysis (EFEA) is a finite element based computational method for high frequency vibration and acoustic analysis. The EFEA solves with finite elements governing differential equations for energy variables. These equations are developed from wave equations. Recently, an EFEA method for computing high frequency vibration of structures either in vacuum or in contact with a dense fluid has been presented. The presence of fluid loading has been considered through added mass and radiation damping. The EFEA developments were validated by comparing EFEA results to solutions obtained by very dense conventional finite element models and solutions from classical techniques such as statistical energy analysis (SEA) and the modal decomposition method for bodies of revolution. EFEA results have also been compared favorably with test data for the vibration and the radiated noise generated by a large scale submersible vehicle. The primary variable in EFEA is defined as the time averaged over a period and space averaged over a wavelength energy density. A joint matrix computed from the power transmission coefficients is utilized for coupling the energy density variables across any discontinuities, such as change of plate thickness, plate/stiffener junctions etc. When considering the high frequency vibration of a periodically stiffened plate or cylinder, the flexural wavelength is smaller than the interval length between two periodic stiffeners, therefore the stiffener stiffness can not be smeared by computing an equivalent rigidity for the plate or cylinder. The periodic stiffeners must be regarded as coupling components between periodic units. In this paper, Periodic Structure (PS) theory is utilized for computing the coupling joint matrix and for accounting for the periodicity characteristics.

  11. Contribution of sensory feedback to plantar flexor muscle activation during push-off in adults with cerebral palsy.

    PubMed

    Frisk, Rasmus F; Jensen, Peter; Kirk, Henrik; Bouyer, Laurent J; Lorentzen, Jakob; Nielsen, Jens B

    2017-12-01

    Exaggerated sensory activity has been assumed to contribute to functional impairment following lesion of the central motor pathway. However, recent studies have suggested that sensory contribution to muscle activity during gait is reduced in stroke patients and children with cerebral palsy (CP). We investigated whether this also occurs in CP adults and whether daily treadmill training is accompanied by alterations in sensory contribution to muscle activity. Seventeen adults with CP and 12 uninjured individuals participated. The participants walked on a treadmill while a robotized ankle-foot orthosis applied unload perturbations at the ankle, thereby removing sensory feedback naturally activated during push-off. Reduction of electromyographic (EMG) activity in the soleus muscle caused by unloads was compared and related to kinematics and ankle joint stiffness measurements. Similar measures were obtained after 6 wk of gait training. We found that sensory contribution to soleus EMG activation was reduced in CP adults compared with uninjured adults. The lowest contribution of sensory feedback was found in participants with lowest maximal gait speed. This was related to increased ankle plantar flexor stiffness. Six weeks of gait training did not alter the contribution of sensory feedback. We conclude that exaggerated sensory activity is unlikely to contribute to impaired gait in CP adults, because sensory contribution to muscle activity during gait was reduced compared with in uninjured individuals. Increased passive stiffness around the ankle joint is likely to diminish sensory feedback during gait so that a larger part of plantar flexor muscle activity must be generated by descending motor commands. NEW & NOTEWORTHY Findings suggest that adults with cerebral palsy have less contribution of sensory feedback to ongoing soleus muscle activation during push-off than uninjured individuals. Increased passive stiffness around the ankle joint is likely to diminish sensory feedback during gait, and/or sensory feedback is less integrated with central motor commands in the activation of spinal motor neurons. Consequently, muscle activation must to a larger extent rely on descending drive, which is already decreased because of the cerebral lesion. Copyright © 2017 the American Physiological Society.

  12. Evaluation of patient-rated stiffness associated with fibromyalgia: a post-hoc analysis of 4 pooled, randomized clinical trials of duloxetine.

    PubMed

    Bennett, Robert; Russell, I Jon; Choy, Ernest; Spaeth, Michael; Mease, Philip; Kajdasz, Daniel; Walker, Daniel; Wang, Fujun; Chappell, Amy

    2012-04-01

    Patients with fibromyalgia (FM) rate stiffness as one of the most troublesome symptoms of the disorder. However, there are few published studies that have focused on better understanding the nature of stiffness in FM. The primary objectives of these analyses were to characterize the distribution of stiffness severity in patients at baseline, evaluate changes in stiffness after 12 weeks of treatment with duloxetine, and determine which outcomes were correlated with stiffness. These were post-hoc analyses of 3-month data from 4 randomized, double-blind, placebo-controlled studies that assessed efficacy of duloxetine in adults with FM. Severity of stiffness was assessed by using the Fibromyalgia Impact Questionnaire (FIQ) on a scale from 0 (no stiffness) to 10 (most severe stiffness). The association between changes in stiffness and other measures was evaluated by using Pearson's correlation coefficient. The FIQ total score and items, the Brief Pain Inventory (BPI-modified short form), the Clinical Global Impression-Severity scale, the Multidimensional Fatigue Inventory, the 17-item Hamilton Depression Rating Scale, the Sheehan Disability Scale, the 36-item Short-Form Health Survey, and the EuroQoL Questionnaire-5 Dimensions were evaluated in the correlation analyses. Stepwise linear regression was used to identify the variables that were most highly predictive of the changes in FIQ stiffness. The analysis included 1332 patients (mean age, 50.2 years; 94.7% female; and 87.8% white). The mean (SD) baseline FIQ stiffness score was 7.7 (2.0), and this score correlated with baseline BPI pain score and FIQ function. Duloxetine significantly improved the FIQ stiffness score compared with placebo (P < 0.001) and provided a moderate effect size (0.23 for the 60-mg dose and 0.38 for the 120-mg dose). Changes in stiffness were best correlated (range, 0.52-0.75; all, P < 0.001) with changes in BPI/FIQ pain and interference scores, FIQ nonrefreshing sleep, FIQ anxiety, 36-item Short-Form Health Survey bodily pain, and Sheehan Disability Scale total score. Variables related to severity of pain, pain interfering with daily activities, and physical functioning were predictors of change in stiffness. Stiffness scores were high in this population with FM and best correlated at baseline with BPI pain score and FIQ function. Not unexpectedly, improvement in stiffness with duloxetine correlated with many of the other markers of FM severity, presumably a result of amelioration in FM comorbidities. Copyright © 2012. Published by EM Inc USA.

  13. Design Study for the Asteroid Redirect Vehicle (ARV) Composite Primary Bulkhead

    NASA Technical Reports Server (NTRS)

    Cressman, Thomas O.; Paddock, David A.

    2017-01-01

    A design study was undertaken of a carbon fiber primary bulkhead for a large solar electric propulsion (SEP) spacecraft. The bulkhead design, supporting up to 16 t of xenon propellant, progressed from one consisting of many simple parts with many complex joints, to one consisting of a few complex parts with a few simple joints. The unique capabilities of composites led to a topology that transitioned loads from bending to in-plane tension and shear, with low part count. This significantly improved bulkhead manufacturability, cost, and mass. The stiffness-driven structure utilized high-modulus M55J fiber unidirectional prepregs. A full-scale engineering demonstration unit (EDU) of the concept was used to demonstrate manufacturability of the concept. Actual labor data was obtained, which could be extrapolated to a full bulkhead. The effort demonstrated the practicality of using high-modulus fiber (HMF) composites for unique shape topologies that minimize mass and cost. The lessons are applicable to primary and secondary aerospace structures that are stiffness driven.

  14. Different TCR-induced T lymphocyte responses are potentiated by stiffness with variable sensitivity

    PubMed Central

    Saitakis, Michael; Dogniaux, Stéphanie; Goudot, Christel; Bufi, Nathalie; Asnacios, Sophie; Maurin, Mathieu; Randriamampita, Clotilde; Asnacios, Atef; Hivroz, Claire

    2017-01-01

    T cells are mechanosensitive but the effect of stiffness on their functions is still debated. We characterize herein how human primary CD4+ T cell functions are affected by stiffness within the physiological Young’s modulus range of 0.5 kPa to 100 kPa. Stiffness modulates T lymphocyte migration and morphological changes induced by TCR/CD3 triggering. Stiffness also increases TCR-induced immune system, metabolism and cell-cycle-related genes. Yet, upon TCR/CD3 stimulation, while cytokine production increases within a wide range of stiffness, from hundreds of Pa to hundreds of kPa, T cell metabolic properties and cell cycle progression are only increased by the highest stiffness tested (100 kPa). Finally, mechanical properties of adherent antigen-presenting cells modulate cytokine production by T cells. Together, these results reveal that T cells discriminate between the wide range of stiffness values found in the body and adapt their responses accordingly. DOI: http://dx.doi.org/10.7554/eLife.23190.001 PMID:28594327

  15. Development of a method for fabricating polypropylene non-articulated dorsiflexion assist ankle foot orthoses with predetermined stiffness.

    PubMed

    Ramsey, Jason Allan

    2011-03-01

    A non-articulated plantarflexion resist ankle foot orthosis (AFO), commonly known as a posterior leaf spring AFO, is indicated for patients with motor impairment to the dorsiflexors. The AFO is often custom molded to a patient's lower limb anatomy and fabricated from polypropylene. There are no established guidelines for fabricating this type of AFO with predetermined stiffness of the ankle region for normal walking speeds. Therefore an AFO may not meet the biomechanical needs of the patient. Quantify the biomechanical ankle stiffness requirement for an individual with complete dorsiflexor impairment and develop a method for fabricating an AFO with ankle stiffness to meet that requirement. Experimental, bench research. The literature on sagittal biomechanics of non-pathological adults was reviewed to derive the stiffness of the ankle during loading response. Computer models of 144 AFOs were created with geometric variations to account for differences in human anthropometrics. Computer-based finite element analysis was employed to determine the stiffness and safety factor of the models. Stiffness of the AFOs ranged from 0.04 to 1.8 Nm/deg. This ample range is expected to account for the stiffness required for most adults with complete dorsiflexor impairment. At 5° deflection the factor of safety (ratio of strength to stress) ranged from 2.8 to 9.1. A computer program was generated that computes AFO stiffness from user-input variables of AFO geometry. The stiffness is compared to a theoretically appropriate stiffness based on the patient mass. The geometric variables can be modified until there is a close match, resulting in AFO design specification that is appropriate for the patient. Through validation on human subjects, this method may benefit patient outcomes in clinical practice by avoiding the current uncertainty surrounding AFO performance and reducing the labor and time involved in rectifying a custom AFO post-fabrication. This method provides an avenue for improving patient outcomes by avoiding the current uncertainty surrounding non-articulated plantarflexion resist ankle foot orthosis performance. The ability to quantify the biomechanical ankle stiffness requirement for an individual with complete dorsiflexor impairment provides insight into how other AFO types should be designed as well.

  16. Acute changes in arterial stiffness following exercise in people with metabolic syndrome.

    PubMed

    Radhakrishnan, Jeyasundar; Swaminathan, Narasimman; Pereira, Natasha M; Henderson, Keiran; Brodie, David A

    This study aims to examine the changes in arterial stiffness immediately following sub-maximal exercise in people with metabolic syndrome. Ninety-four adult participants (19-80 years) with metabolic syndrome gave written consent and were measured for arterial stiffness using a SphygmoCor (SCOR-PVx, Version 8.0, Atcor Medical Private Ltd, USA) immediately before and within 5-10min after an incremental shuttle walk test. The arterial stiffness measures used were pulse wave velocity (PWV), aortic pulse pressure (PP), augmentation pressure, augmentation index (AI), subendocardial viability ratio (SEVR) and ejection duration (ED). There was a significant increase (p<0.05) in most of the arterial stiffness variables following exercise. Exercise capacity had a strong inverse correlation with arterial stiffness and age (p<0.01). Age influences arterial stiffness. Exercise capacity is inversely related to arterial stiffness and age in people with metabolic syndrome. Exercise induced changes in arterial stiffness measured using pulse wave analysis is an important tool that provides further evidence in studying cardiovascular risk in metabolic syndrome. Copyright © 2016 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  17. Muscular contribution to low-back loading and stiffness during standard and suspended push-ups.

    PubMed

    Beach, Tyson A C; Howarth, Samuel J; Callaghan, Jack P

    2008-06-01

    Push-up exercises are normally performed to challenge muscles that span upper extremity joints. However, it is also recognized that push-ups provide an effective abdominal muscle challenge, especially when the hands are in contact with a labile support surface. The purpose of this study was to compare trunk muscle activation levels and resultant intervertebral joint (IVJ) loading when standard and suspended push-ups were performed, and to quantify and compare the contribution of trunk muscles to IVJ rotational stiffness in both exercises. Eleven recreationally trained male volunteers performed sets of standard and suspended push-ups. Upper body kinematic, kinetic, and EMG data were collected and input into a 3D biomechanical model of the lumbar torso to quantify lumbar IVJ loading and the contributions of trunk muscles to IVJ rotational stiffness. When performing suspended push-ups, muscles of the abdominal wall and the latissimus dorsi were activated to levels that were significantly greater than those elicited when performing standard push-ups (p<.05). As a direct result of these increased activation levels, model-predicted muscle forces increased and consequently led to significantly greater mean (p=.0008) and peak (p=.0012) lumbar IVJ compressive forces when performing suspended push-ups. Also directly resulting from the increased activation levels of the abdominal muscles and the latissimus dorsi during suspended push-ups was increased muscular contribution to lumbar IVJ rotational stiffness (p<.05). In comparison to the standard version of the exercise, suspended push-ups appear to provide a superior abdominal muscle challenge. However, for individuals unable to tolerate high lumbar IVJ compressive loads, potential benefits gained by incorporating suspended push-ups into their resistance training regimen may be outweighed by the risk of overloading low-back tissues.

  18. An Investigation of the Tensile Strength of a Composite-To-Metal Adhesive Joint

    NASA Astrophysics Data System (ADS)

    Tsouvalis, Nicholas G.; Karatzas, Vassilios A.

    2011-04-01

    The present study examines the feasibility of a simple concept composite-to-metal butt joint through the performance of both numerical and experimental studies. The composite part is made of glass/epoxy unidirectional layers made with the vacuum bag method. The geometry of the joint is typical for marine applications and corresponds to a low stiffness ratio. Two major parameters are investigated, namely the overlap length and the surface preparation of the steel adherent. Manufacturing of specimens and the procedure of the tensile tests are described in detail, giving hints for obtaining a better quality joint. Axial elongation and strains at various places of the joint were monitored and also numerically calculated. The tests revealed that the joint is quite effective, irrespectively of the steel surface preparation method. The failure loads are comparable and in some cases superior to other corresponding values found in the literature. The numerical models proved to adequately predict the structural response of the joint up to the loading where debonding starts.

  19. Design Methodology for Scarf Repairs to Composite Structures

    DTIC Science & Technology

    2006-08-01

    particularly for laminates containing unidirectional ( tape ) plies, where the variation in stiffness along the scarf is significant. (a) A scarf...London. p. 610-666. 5. Lubkin, J.L., A theory of adhesive scarf joints. Journal of Applied Mechanics, 1956. July 1957: p. 255-260. 6. Erdogan , F

  20. Effects of phyllotaxy on biomechanical properties of stems of Cercis occidentalis (Fabaceae).

    PubMed

    Caringella, Marissa A; Bergman, Brett A; Stanfield, Ryan C; Ewers, Madeleine M; Bobich, Edward G; Ewers, Frank W

    2014-01-01

    Phyllotaxy, the arrangement of leaves on a stem, may impact the mechanical properties of woody stems several years after the leaves have been shed. We explored mechanical properties of a plant with alternate distichous phyllotaxy, with a row of leaves produced on each side of the stem, to determine whether the nodes behave as spring-like joints. Flexural stiffness of 1 cm diameter woody stems was measured in four directions with an Instron mechanical testing system; the xylem of the stems was then cut into node (former leaf junction) and nonnode segments for measurement of xylem density. Stems had 20% greater flexural stiffness in the plane perpendicular to the original leaf placement than in the parallel plane. The xylem in the node region was more flexible, but it had significantly greater tissue density than adjacent regions, contradicting the usual correlation between wood density and stiffness. Nodes can behave as spring-like joints in woody plants. For plagiotropic shoots, distichous phyllotaxy results in stems that resist up-and-down bending more than lateral back-and-forth movement. Thus, they may more effectively absorb applied loads from fruits, animals, wind, rain, and snow and resist stresses due to gravity without cracking and breaking. Under windy conditions, nodes may improve damping by absorbing vibrational energy and thus reducing oscillation damage. The effect of plant nodes also has biomimetic design implications for architects and material engineers.

  1. Motor Inhibition Affects the Speed But Not Accuracy of Aimed Limb Movements in an Insect

    PubMed Central

    Calas-List, Delphine; Clare, Anthony J.; Komissarova, Alexandra; Nielsen, Thomas A.

    2014-01-01

    When reaching toward a target, human subjects use slower movements to achieve higher accuracy, and this can be accompanied by increased limb impedance (stiffness, viscosity) that stabilizes movements against motor noise and external perturbation. In arthropods, the activity of common inhibitory motor neurons influences limb impedance, so we hypothesized that this might provide a mechanism for speed and accuracy control of aimed movements in insects. We recorded simultaneously from excitatory leg motor neurons and from an identified common inhibitory motor neuron (CI1) in locusts that performed natural aimed scratching movements. We related limb movement kinematics to recorded motor activity and demonstrate that imposed alterations in the activity of CI1 influenced these kinematics. We manipulated the activity of CI1 by injecting depolarizing or hyperpolarizing current or killing the cell using laser photoablation. Naturally higher levels of inhibitory activity accompanied faster movements. Experimentally biasing the firing rate downward, or stopping firing completely, led to slower movements mediated by changes at several joints of the limb. Despite this, we found no effect on overall movement accuracy. We conclude that inhibitory modulation of joint stiffness has effects across most of the working range of the insect limb, with a pronounced effect on the overall velocity of natural movements independent of their accuracy. Passive joint forces that are greatest at extreme joint angles may enhance accuracy and are not affected by motor inhibition. PMID:24872556

  2. Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.

    2010-01-01

    Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

  3. Pericellular plasma clot negates the influence of scaffold stiffness on chondrogenic differentiation.

    PubMed

    Arora, Aditya; Kothari, Anjaney; Katti, Dhirendra S

    2016-12-01

    Matrix stiffness is known to play a pivotal role in cellular differentiation. Studies have shown that soft scaffolds (<2-3kPa) promote cellular aggregation and chondrogenesis, whereas, stiffer ones (>10kPa) show poor chondrogenesis in vitro. In this work we investigated if fibrin matrix from clotted blood can act as a soft surrogate which nullifies the influence of the underlying stiff scaffold, thus promoting chondrogenesis irrespective of bulk scale scaffold stiffness. For this we performed in vitro chondrogenesis on soft (∼1.5kPa) and stiff (∼40kPa) gelatin scaffolds in the presence and absence of pericellular plasma clot. Our results demonstrated that in absence of pericellular plasma clot, chondrocytes showed efficient condensation and cartilaginous matrix secretion only on soft scaffolds, whereas, in presence of pericellular plasma clot, cell rounding and cartilaginous matrix secretion was observed in both soft and stiff scaffolds. More specifically, significantly higher collagen II, chondroitin sulfate and aggrecan deposition was observed in soft scaffolds, and soft and stiff scaffolds with pericellular plasma clot as compared to stiff scaffolds without pericellular plasma clot. Moreover, collagen type I, a fibrocartilage/bone marker was significantly higher only in stiff scaffolds without plasma clot. Therefore, it can be concluded that chondrocytes surrounded by a soft fibrin network were unable to sense the stiffness of the underlying scaffold/substrate and hence facilitate chondrogenesis even on stiff scaffolds. This understanding can have significant implications in the design of scaffolds for cartilage tissue engineering. Cell fate is influenced by the mechanical properties of cell culture substrates. Outside the body, cartilage progenitor cells express significant amounts of cartilage-specific markers on soft scaffolds but not on stiff scaffolds. However, when implanted in joints, stiff scaffolds show equivalent expression of markers as seen in soft scaffolds. This disparity in existing literature prompted our study. Our results suggest that encapsulation of cells in a soft plasma clot, present in any surgical intervention, prevents their perception of stiffness of the underlying scaffold, and hence the ability to distinguish between soft and stiff scaffolds vanishes. This finding would aid the design of new scaffolds that elicit cartilage-like biochemical properties while simultaneously being mechanically comparable to cartilage tissue. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. Feedback-controlled and programmed stretching of the ankle plantarflexors and dorsiflexors in stroke: effects of a 4-week intervention program.

    PubMed

    Selles, Ruud W; Li, Xiaoyan; Lin, Fang; Chung, Sun G; Roth, Elliot J; Zhang, Li-Qun

    2005-12-01

    To investigate the effect of repeated feedback-controlled and programmed "intelligent" stretching of the ankle plantar- and dorsiflexors to treat subjects with ankle spasticity and/or contracture in stroke. Noncontrolled trial. Institutional research center. Subjects with spasticity and/or contracture after stroke. Stretching of the plantar- and dorsiflexors of the ankle 3 times a week for 45 minutes during a 4-week period by using a feedback-controlled and programmed stretching device. Passive and active range of motion (ROM), muscle strength, joint stiffness, joint viscous damping, reflex excitability, comfortable walking speed, and subjective experiences of the subjects. Significant improvements were found in the passive ROM, maximum voluntary contraction, ankle stiffness, and comfortable walking speed. The visual analog scales indicated very positive subjective evaluation in terms of the comfort of stretching and the effect on their involved ankle. Repeated feedback-controlled or intelligent stretching had a positive influence on the joint properties of the ankle with spasticity and/or contracture after stroke. The stretching device may be an effective and safe alternative to manual passive motion treatment by a therapist and has potential to be used to repeatedly and regularly stretch the ankle of subjects with spasticity and/or contracture without daily involvement of clinicians or physical therapists.

  5. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning.

    PubMed

    Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-02-01

    Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.

  6. Buckling and Post-Buckling Behaviors of a Variable Stiffness Composite Laminated Wing Box Structure

    NASA Astrophysics Data System (ADS)

    Wang, Peiyan; Huang, Xinting; Wang, Zhongnan; Geng, Xiaoliang; Wang, Yuansheng

    2018-04-01

    The buckling and post-buckling behaviors of variable stiffness composite laminates (VSCL) with curvilinear fibers were investigated and compared with constant stiffness composite laminates (CSCL) with straight fibers. A VSCL box structure was evaluated under a pure bending moment. The results of the comparative test showed that the critical buckling load of the VSCL box was approximately 3% higher than that of the CSCL box. However, the post-buckling load-bearing capacity was similar due to the layup angle and the immature status of the material processing technology. The properties of the VSCL and CSCL boxes under a pure bending moment were simulated using the Hashin criterion and cohesive interface elements. The simulation results are consistent with the experimental results in stiffness, critical buckling load and failure modes but not in post-buckling load capacity. The results of the experiment, the simulation and laminated plate theory show that VSCL greatly improves the critical buckling load but has little influence on the post-buckling load-bearing capacity.

  7. Morphological Computation of Haptic Perception of a Controllable Stiffness Probe

    PubMed Central

    Sornkarn, Nantachai; Dasgupta, Prokar; Nanayakkara, Thrishantha

    2016-01-01

    When people are asked to palpate a novel soft object to discern its physical properties such as texture, elasticity, and even non-homogeneity, they not only regulate probing behaviors, but also the co-contraction level of antagonistic muscles to control the mechanical impedance of fingers. It is suspected that such behavior tries to enhance haptic perception by regulating the function of mechanoreceptors at different depths of the fingertips and proprioceptive sensors such as tendon and spindle sensors located in muscles. In this paper, we designed and fabricated a novel two-degree of freedom variable stiffness indentation probe to investigate whether the regulation of internal stiffness, indentation, and probe sweeping velocity (PSV) variables affect the accuracy of the depth estimation of stiff inclusions in an artificial silicon phantom using information gain metrics. Our experimental results provide new insights into not only the biological phenomena of haptic perception but also new opportunities to design and control soft robotic probes. PMID:27257814

  8. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning

    PubMed Central

    Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-01-01

    Abstract Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally. PMID:29412080

  9. Influence of Passive Stiffness of Hamstrings on Postural Stability

    PubMed Central

    Kuszewski, Michał; Gnat, Rafał; Sobota, Grzegorz; Myśliwiec, Andrzej

    2015-01-01

    The aim of the study was to explore whether passive stiffness of the hamstrings influences the strategy of maintaining postural stability. A sample of 50 subjects was selected; the final analyses were based on data of 41 individuals (33 men, 8 women) aged 21 to 29 (mean = 23.3, SD = 1.1) years. A quasi- experimental ex post facto design with repeated measures was used. Categories of independent variables were obtained directly prior to the measurement of the dependent variables. In stage one of the study, passive knee extension was measured in the supine position to assess hamstring stiffness. In stage two, the magnitude of postural sway in antero-posterior direction was measured, while varying the body position on a stabilometric platform, both with and without visual control. The margin of safety was used as a measure of postural control. The magnitude of the margin of safety increased significantly between the open-eye and closed-eye trials. However, although we registered a visible tendency for a larger increase of the margin of safety associated with lower levels of passive hamstrings stiffness, no significant differences were found. Therefore, this study demonstrated that hamstring stiffness did not influence the strategy used to maintain postural stability. PMID:25964809

  10. Influence of passive stiffness of hamstrings on postural stability.

    PubMed

    Kuszewski, Michał; Gnat, Rafał; Sobota, Grzegorz; Myśliwiec, Andrzej

    2015-03-29

    The aim of the study was to explore whether passive stiffness of the hamstrings influences the strategy of maintaining postural stability. A sample of 50 subjects was selected; the final analyses were based on data of 41 individuals (33 men, 8 women) aged 21 to 29 (mean = 23.3, SD = 1.1) years. A quasi- experimental ex post facto design with repeated measures was used. Categories of independent variables were obtained directly prior to the measurement of the dependent variables. In stage one of the study, passive knee extension was measured in the supine position to assess hamstring stiffness. In stage two, the magnitude of postural sway in antero-posterior direction was measured, while varying the body position on a stabilometric platform, both with and without visual control. The margin of safety was used as a measure of postural control. The magnitude of the margin of safety increased significantly between the open-eye and closed-eye trials. However, although we registered a visible tendency for a larger increase of the margin of safety associated with lower levels of passive hamstrings stiffness, no significant differences were found. Therefore, this study demonstrated that hamstring stiffness did not influence the strategy used to maintain postural stability.

  11. Reverse Dynamization: Influence of Fixator Stiffness on the Mode and Efficiency of Large-Bone-Defect Healing at Different Doses of rhBMP-2.

    PubMed

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-04-20

    Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Exercise Helps Ease Arthritis Pain and Stiffness

    MedlinePlus

    ... you control your weight Enhance your quality of life Improve your balance Though you might think exercise will aggravate your ... involved. Your doctor or a physical therapist can work with you to find the exercise plan that gives you the most benefit with the least aggravation of your joint pain. ...

  13. Concrete pedestals for high-performance semiconductor production equipment

    NASA Astrophysics Data System (ADS)

    Vogen, Wayne; Franklin, Craig L.; Morneault, Joseph

    1999-09-01

    Concrete pedestals have many vibration and stiffness characteristics that make them a superior choice for sensitive semiconductor production equipment including scanners, scanning electron microscopes, focused ion beam millers and optical inspection equipment. Among the advantages of concrete pedestals are high inherent damping, monolithic construction that eliminates low stiffness joints common in steep pedestals, ability to reuse and ease of installation. Steel pedestals that have plates attached to the top of the frame are easily excited by acoustic excitation, especially in the range from 50 Hertz to 400 Hertz. Concrete pedestals do not suffer from this phenomenon because of the high mass and damping of the top surface.

  14. Design of a 6-DOF upper limb rehabilitation exoskeleton with parallel actuated joints.

    PubMed

    Chen, Yanyan; Li, Ge; Zhu, Yanhe; Zhao, Jie; Cai, Hegao

    2014-01-01

    In this paper, a 6-DOF wearable upper limb exoskeleton with parallel actuated joints which perfectly mimics human motions is proposed. The upper limb exoskeleton assists the movement of physically weak people. Compared with the existing upper limb exoskeletons which are mostly designed using a serial structure with large movement space but small stiffness and poor wearable ability, a prototype for motion assistance based on human anatomy structure has been developed in our design. Moreover, the design adopts balls instead of bearings to save space, which simplifies the structure and reduces the cost of the mechanism. The proposed design also employs deceleration processes to ensure that the transmission ratio of each joint is coincident.

  15. Adhesive-bonded double-lap joints. [analytical solutions for static load carrying capacity

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1973-01-01

    Explicit analytical solutions are derived for the static load carrying capacity of double-lap adhesive-bonded joints. The analyses extend the elastic solution Volkersen and cover adhesive plasticity, adherend stiffness imbalance and thermal mismatch between the adherends. Both elastic-plastic and bi-elastic adhesive representations lead to the explicit result that the influence of the adhesive on the maximum potential bond strength is defined uniquely by the strain energy in shear per unit area of bond. Failures induced by peel stresses at the ends of the joint are examined. This failure mode is particularly important for composite adherends. The explicit solutions are sufficiently simple to be used for design purposes

  16. A new active variable stiffness suspension system using a nonlinear energy sink-based controller

    NASA Astrophysics Data System (ADS)

    Anubi, Olugbenga Moses; Crane, Carl D.

    2013-10-01

    This paper presents the active case of a variable stiffness suspension system. The central concept is based on a recently designed variable stiffness mechanism which consists of a horizontal control strut and a vertical strut. The horizontal strut is used to vary the load transfer ratio by actively controlling the location of the point of attachment of the vertical strut to the car body. The control algorithm, effected by a hydraulic actuator, uses the concept of nonlinear energy sink (NES) to effectively transfer the vibrational energy in the sprung mass to a control mass, thereby reducing the transfer of energy from road disturbance to the car body at a relatively lower cost compared to the traditional active suspension using the skyhook concept. The analyses and simulation results show that a better performance can be achieved by subjecting the point of attachment of a suspension system, to the chassis, to the influence of a horizontal NES system.

  17. Articular cartilage. Part II. The osteoarthritic joint.

    PubMed

    Muehleman, C; Arsenis, C H

    1995-05-01

    Articular hyaline cartilage, though a metabolically active tissue, has limited capacity for repair. Though the integrity of the cartilage is dependent upon a certain level of force placed upon it, excessive force leads to damage. It is when the breakdown of the cartilage exceeds the capacity of the cartilage for repair that osteoarthritis results. At present, pharmacologic treatment of osteoarthritis is focused toward the control of pain and stiffness. This treatment, however, masks the symptoms of the disease and effectively allows the patient to do further damage to the joint.

  18. Management of proximal interphalangeal joint injuries

    PubMed Central

    Freiberg, Arnis

    2007-01-01

    Injuries to the proximal interphalangeal joint are common but frequently missed. They are often overtreated by prolonged immobilization, resulting in stiffness, which may be permanent. The purpose of the present article is to briefly review the relevant anatomy and biomechanics, present an approach to physical examination and diagnosis, and propose a practical clinical classification. The treatment of the most severe injury – the intra-articular fracture dislocation – is controversial. The various treatment options are discussed, based on personal experience and a review of the literature. A list of relevant references is presented. PMID:19554177

  19. Importance of mechanics and kinematics in determining the stiffness contribution of the vertebral column during body-caudal-fin swimming in fishes.

    PubMed

    Nowroozi, Bryan N; Brainerd, Elizabeth L

    2014-02-01

    Whole-body stiffness in fishes has important consequences for swimming mode, speed and efficiency, but the contribution of vertebral column stiffness to whole-body stiffness is unclear. In our opinion, this lack of clarity is due in part to the lack of studies that have measured both in vitro mechanical properties of the vertebral column as well as in vivo vertebral kinematics in the same species. Some lack of clarity may also come from real variation in the mechanical role of the vertebral column across species. Previous studies, based on either mechanics or kinematics alone, suggest species-specific variation in vertebral column locomotor function that ranges from highly stiff regimes that contribute greatly to whole-body stiffness, and potentially act as a spring, to highly compliant regimes that only prohibit excessive flexion of the intervertebral joints. We review data collected in combined investigations of both mechanics and kinematics of three species, Myxine glutinosa, Acipenser transmontanus, and Morone saxatilis, to illustrate how mechanical testing within the context of the in vivo kinematics more clearly distinguishes the role of the vertebral column in each species. In addition, we identify species for which kinematic data are available, but mechanical data are lacking. We encourage further investigation of these species to fill these mechanical data gaps. Finally, we hope these future combined analyses will identify certain morphological, mechanical, or kinematic parameters that might be associated with certain vertebral column functional regimes with respect to body stiffness. Copyright © 2013 Elsevier GmbH. All rights reserved.

  20. [Functional status, self-rated health and level of physical activity of patients with osteoarthritis].

    PubMed

    Val Jiménez, Carmen Llanos; López-Torres Hidalgo, Jesús; García Atienza, Eva María; Navarro Ruiz, María Soledad; Hernández Cerón, Inmaculada; Moreno de la Rosa, Lorena

    2017-04-01

    To describe the functional status and self-rated health of patients with osteoarthritis (OA) in Primary Care, and checking their relationship with the level of physical activity and sociodemographic characteristics. Study of prevalence and cross association. Primary Care Clinics. Adult patients with a diagnosis of OA in any joint in their clinical records. Out of a total of 487 selected, 346 (71.0%) took part in the study. Functional capacity (WOMAC scale), self-rated quality of life (EuroQol- 5D questionnaire), physical activity (IPAQ questionnaire), number of affected joints, pain level, and sociodemographic characteristics. A mean score of 30.2 (SD: 20.8; CI 95% CI: 28.0 to 32.4) was obtained on the WOMAC scale, with pain, stiffness, and functional capacity scores of 6.5 (SD: 4.8), 1.9 (SD: 2.0), and 21.7 (SD: 15.7), respectively. The score showed a linear trend (P<.001) compared to the level of physical activity, being 41.1 (SD: 19.9) in inactive subjects, 24.3 (SD: 18.7) in subjects with moderate activity, and 22.3 (SD: 19.8) in subjects with intense activity. In the multiple linear regression, the score on the WOMAC scale, as well as that obtained in self-rated health status, maintained their association with physical activity level after adjusting for sociodemographic variables and the number of affected joints. In patients with OA, pain and functional capacity are the most affected dimensions. Functional status and self-rated health status are higher in active patients, regardless of the number of joints affected and their demographic characteristics. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  1. “An Impediment to Living Life”: Why and How Should We Measure Stiffness in Polymyalgia Rheumatica?

    PubMed Central

    Mackie, Sarah Louise; Hughes, Rodney; Walsh, Margaret; Day, John; Newton, Marion; Pease, Colin; Kirwan, John; Morris, Marianne

    2015-01-01

    Objectives To explore patients’ concepts of stiffness in polymyalgia rheumatica (PMR), and how they think stiffness should be measured. Methods Eight focus groups were held at three centres involving 50 patients with current/previous PMR. Each group had at least one facilitator and one rapporteur making field notes. An interview schedule was used to stimulate discussion. Interviews were recorded, transcribed and analysed using an inductive thematic approach. Results Major themes identified were: symptoms: pain, stiffness and fatigue; functional impact; impact on daily schedule; and approaches to measurement. The common subtheme for the experience of stiffness was “difficulty in moving”, and usually considered as distinct from the experience of pain, albeit with a variable overlap. Some participants felt stiffness was the “overwhelming” symptom, in that it prevented them carrying out “fundamental activities” and “generally living life”. Diurnal variation in stiffness was generally described in relation to the daily schedule but was not the same as stiffness severity. Some participants suggested measuring stiffness using a numeric rating scale or a Likert scale, while others felt that it was more relevant and straightforward to measure difficulty in performing everyday activities rather than about stiffness itself. Conclusions A conceptual model of stiffness in PMR is presented where stiffness is an important part of the patient experience and impacts on their ability to live their lives. Stiffness is closely related to function and often regarded as interchangeable with pain. From the patients’ perspective, visual analogue scales measuring pain and stiffness were not the most useful method for reporting stiffness; participants preferred numerical rating scales, or assessments of function to reflect how stiffness impacts on their daily lives. Assessing function may be a pragmatic solution to difficulties in quantifying stiffness. PMID:25955770

  2. Associations between yoga practice and joint problems: a cross-sectional survey among 9151 Australian women.

    PubMed

    Lauche, Romy; Schumann, Dania; Sibbritt, David; Adams, Jon; Cramer, Holger

    2017-07-01

    Yoga exercises have been associated with joint problems recently, indicating that yoga practice might be potentially dangerous for joint health. This study aimed to analyse whether regular yoga practice is associated with the frequency of joint problems in upper middle-aged Australian women. Women aged 62-67 years from the Australian Longitudinal Study on Women's Health (ALSWH) were questioned in 2013 whether they experienced regular joint pain or problems in the past 12 months and whether they regularly practiced yoga. Associations of joint problems with yoga practice were analysed using Chi-squared tests and multiple logistic regression modelling. Of 9151 women, 29.8% reported regular problems with stiff or painful joints, and 15.2, 11.9, 18.1 and 15.9% reported regular problems with shoulders, hips, knees and feet, respectively, in the past 12 months. Yoga was practiced sometimes by 10.1% and often by 8.4% of women. Practicing yoga was not associated with upper or lower limb joint problems. No association between yoga practice and joint problems has been identified. Further studies are warranted for conclusive judgement of benefits and safety of yoga in relation to joint problems.

  3. The cyclic fatigue behavior of adhesive joints

    NASA Astrophysics Data System (ADS)

    Kinloch, A. J.; Toh, T.

    1995-06-01

    In the last six months we have: (1) Concentrated our efforts on the fatigue failure of carbon-fiber PEEK/AFl63 lap joints, and in particular we have started to predict the life time of single-lap joints under cyclic fatigue loading. The analysis is based on data obtained from double cantilever beam (DCB) fracture mechanics tests; (2) Further, we have been successful in measuring the rate of crack growth in lap joints during fatigue fracture using ultrasonic scanning; (3) Preliminary test data on the static fracture of glass-fiber reinforced poly(phenylene sulphide) (PPS)/AF163 joints have also been studied; and (4) A comparison has been made in computing the critical strain energy release rate G(sub c) for the glass-fiber PPS/AF163 joints based on the compliance method, beam theory and corrected beam theory. The last method accounts for large non-linear deflections and the associated crack root rotations along with the necessary corrections for the increase in stiffness introduced by the presence of end blocks.

  4. Bio-inspired flexible joints with passive feathering for robotic fish pectoral fins.

    PubMed

    Behbahani, Sanaz Bazaz; Tan, Xiaobo

    2016-05-04

    In this paper a novel flexible joint is proposed for robotic fish pectoral fins, which enables a swimming behavior emulating the fin motions of many aquatic animals. In particular, the pectoral fin operates primarily in the rowing mode, while undergoing passive feathering during the recovery stroke to reduce hydrodynamic drag on the fin. The latter enables effective locomotion even with symmetric base actuation during power and recovery strokes. A dynamic model is developed to facilitate the understanding and design of the joint, where blade element theory is used to calculate the hydrodynamic forces on the pectoral fins, and the joint is modeled as a paired torsion spring and damper. Experimental results on a robotic fish prototype are presented to illustrate the effectiveness of the joint mechanism, validate the proposed model, and indicate the utility of the proposed model for the optimal design of joint depth and stiffness in achieving the trade-off between swimming speed and mechanical efficiency.

  5. Finite element based nonlinear normalization of human lumbar intervertebral disc stiffness to account for its morphology.

    PubMed

    Maquer, Ghislain; Laurent, Marc; Brandejsky, Vaclav; Pretterklieber, Michael L; Zysset, Philippe K

    2014-06-01

    Disc degeneration, usually associated with low back pain and changes of intervertebral stiffness, represents a major health issue. As the intervertebral disc (IVD) morphology influences its stiffness, the link between mechanical properties and degenerative grade is partially lost without an efficient normalization of the stiffness with respect to the morphology. Moreover, although the behavior of soft tissues is highly nonlinear, only linear normalization protocols have been defined so far for the disc stiffness. Thus, the aim of this work is to propose a nonlinear normalization based on finite elements (FE) simulations and evaluate its impact on the stiffness of human anatomical specimens of lumbar IVD. First, a parameter study involving simulations of biomechanical tests (compression, flexion/extension, bilateral torsion and bending) on 20 FE models of IVDs with various dimensions was carried out to evaluate the effect of the disc's geometry on its compliance and establish stiffness/morphology relations necessary to the nonlinear normalization. The computed stiffness was then normalized by height (H), cross-sectional area (CSA), polar moment of inertia (J) or moments of inertia (Ixx, Iyy) to quantify the effect of both linear and nonlinear normalizations. In the second part of the study, T1-weighted MRI images were acquired to determine H, CSA, J, Ixx and Iyy of 14 human lumbar IVDs. Based on the measured morphology and pre-established relation with stiffness, linear and nonlinear normalization routines were then applied to the compliance of the specimens for each quasi-static biomechanical test. The variability of the stiffness prior to and after normalization was assessed via coefficient of variation (CV). The FE study confirmed that larger and thinner IVDs were stiffer while the normalization strongly attenuated the effect of the disc geometry on its stiffness. Yet, notwithstanding the results of the FE study, the experimental stiffness showed consistently higher CV after normalization. Assuming that geometry and material properties affect the mechanical response, they can also compensate for one another. Therefore, the larger CV after normalization can be interpreted as a strong variability of the material properties, previously hidden by the geometry's own influence. In conclusion, a new normalization protocol for the intervertebral disc stiffness in compression, flexion, extension, bilateral torsion and bending was proposed, with the possible use of MRI and FE to acquire the discs' anatomy and determine the nonlinear relations between stiffness and morphology. Such protocol may be useful to relate the disc's mechanical properties to its degree of degeneration.

  6. Reliability of Tin Silver Copper and mixed solders under variable loading conditions

    NASA Astrophysics Data System (ADS)

    Jaradat, Younis

    Industry use of lead free solder joints necessitates accurate modeling in predicting life in service. Yet, current extrapolations of accelerated test results do not actuate realistic conditions. This research focuses on joint properties of Pb-mixed and Pb-free solder alloys in order to explain material behavior subject to certain test conditions, i.e., varying cycling amplitudes. Additionally, this research will begin with extensive studies on backward compatible solder joints from the material's behavior to its reliability under displacement and load controlled fatigue tests. We address the evolution of the joint's microstructure ergo its properties and performance (mixed solder joints). The present work reports results of reflowing 30 mil SAC305 balls onto Cu, and ENIG coated BGA pads with different amounts of SnPb paste, aging and/or cycling the joints and inspecting the microstructure by cross polarizer microscopy and SEM. We found that the addition of small amounts of Pb had significant effects on solidification during cool-down from reflow, and consequently the initial microstructure. In terms of the varying cycling amplitude study, we note how realistic service conditions are almost never well approximated by cycling with fixed amplitudes. Recent results have demonstrated the consistent breakdown of common damage accumulation rules. In isothermal cycling tests the remaining life, after a step-down in amplitude, was invariably shorter than predicted by such a rule, while a step-up tended to have the opposite effect. The present work offers a mechanistic explanation for this and the basis for a practical approach to the assessment of life under service conditions. Realistic BGA joints were cycled individually in a micromechanical tester, monitoring the solder stiffness and the inelastic energy deposition. Cycling was seen to first cause rapid hardening, followed by leveling off in a 'cyclic saturation' stage and eventually the initiation and growth of a crack until failure. A temporary increase in amplitude during cycling caused a lasting reduction in hardness, and thus enhanced inelastic energy deposition and damage evolution, after the fact. This factor dominates during repeated increases and decreases, eventually shortening the remaining life dramatically

  7. Finite Element Analysis of Increasing Column Section and CFRP Reinforcement Method under Different Axial Compression Ratio

    NASA Astrophysics Data System (ADS)

    Jinghai, Zhou; Tianbei, Kang; Fengchi, Wang; Xindong, Wang

    2017-11-01

    Eight less stirrups in the core area frame joints are simulated by ABAQUS finite element numerical software. The composite reinforcement method is strengthened with carbon fiber and increasing column section, the axial compression ratio of reinforced specimens is 0.3, 0.45 and 0.6 respectively. The results of the load-displacement curve, ductility and stiffness are analyzed, and it is found that the different axial compression ratio has great influence on the bearing capacity of increasing column section strengthening method, and has little influence on carbon fiber reinforcement method. The different strengthening schemes improve the ultimate bearing capacity and ductility of frame joints in a certain extent, composite reinforcement joints strengthening method to improve the most significant, followed by increasing column section, reinforcement method of carbon fiber reinforced joints to increase the minimum.

  8. Effects of forefoot bending stiffness of badminton shoes on agility, comfort perception and lower leg kinematics during typical badminton movements.

    PubMed

    Park, Sang-Kyoon; Lam, Wing-Kai; Yoon, Sukhoon; Lee, Ki-Kwang; Ryu, Jiseon

    2017-09-01

    This study investigated whether an increase in the forefoot bending stiffness of a badminton shoe would positively affect agility, comfort and biomechanical variables during badminton-specific movements. Three shoe conditions with identical shoe upper and sole designs with different bending stiffness (Flexible, Regular and Stiff) were used. Elite male badminton players completed an agility test on a standard badminton court involving consecutive lunges in six directions, a comfort test performed by a pair of participants conducting a game-like practice trial and a biomechanics test involving a random assignment of consecutive right forward lunges. No significant differences were found in agility time and biomechanical variables among the three shoes. The players wearing the shoe with a flexible forefoot outsole demonstrated a decreased perception of comfort in the forefoot cushion compared to regular and stiffer conditions during the comfort test (p < 0.05). The results suggested that the modification of forefoot bending stiffness would influence individual perception of comfort but would not influence performance and lower extremity kinematics during the tested badminton-specific tasks. It was concluded that an optimisation of forefoot structure and materials in badminton shoes should consider the individual's perception to maximise footwear comfort in performance.

  9. Reliability of Leg and Vertical Stiffness During High Speed Treadmill Running.

    PubMed

    Pappas, Panagiotis; Dallas, Giorgos; Paradisis, Giorgos

    2017-04-01

    In research, the accurate and reliable measurement of leg and vertical stiffness could contribute to valid interpretations. The current study aimed at determining the intraparticipant variability (ie, intraday and interday reliabilities) of leg and vertical stiffness, as well as related parameters, during high speed treadmill running, using the "sine-wave" method. Thirty-one males ran on a treadmill at 6.67 m∙s -1 , and the contact and flight times were measured. To determine the intraday reliability, three 10-s running bouts with 10-min recovery were performed. In addition, to examine the interday reliability, three 10-s running bouts on 3 separate days with 48-h interbout intervals were performed. The reliability statistics included repeated-measure analysis of variance, average intertrial correlations, intraclass correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation (CV%). Both intraday and interday reliabilities were high for leg and vertical stiffness (ICC > 0.939 and CV < 4.3%), as well as related variables (ICC > 0.934 and CV < 3.9%). It was thus inferred that the measurements of leg and vertical stiffness, as well as the related parameters obtained using the "sine-wave" method during treadmill running at 6.67 m∙s -1 , were highly reliable, both within and across days.

  10. Morning pressor surge, blood pressure variability, and arterial stiffness in essential hypertension.

    PubMed

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Schillaci, Giuseppe

    2017-02-01

    An excess morning blood pressure surge (MBPS) may portend an increased cardiovascular risk, but the mechanisms thereof have been little investigated. The link between MBPS, short-term blood pressure (BP) variability, and arterial stiffness has not been entirely defined. In 602 consecutive untreated hypertensive patients (48 ± 12 years, 61% men, office BP 149/93 ± 17/10 mmHg), we measured carotid-femoral pulse wave velocity (cf-PWV, SphygmoCor) and 24-h ambulatory BP. Using self-reported sleep and wake times, MBPS was defined as sleep-trough (ST-MBPS), prewaking, rising. Short-term BP variability was calculated as weighted 24-h SBP SD and average real variability of 24-h SBP (ARV), that is, average of absolute differences between consecutive SBP readings. ST-MBPS (r = 0.16, P < 0.001) and rising MBPS (r = 0.12, P = 0.003) showed a direct correlation with cf-PWV, whereas prewaking MBPS had no such relation (r = 0.06, P = 0.14). Only ST-MBPS was independently associated with cf-PWV (t = 1.96, P = 0.04) after adjustment for age, sex, height, office mean arterial pressure, heart rate, and renal function. This association was lost after further adjustment for weighted 24-h SBP SD (P = 0.13) or ARV (P = 0.24). ARV was a significant mediator of the relationship between ST-MBPS and cf-PWV (P = 0.003). In untreated hypertension, ST-MBPS has a direct relation with aortic stiffness, which is mediated by an increased ARV. The adverse effects of MBPS may be partly explained by its link with arterial stiffness, mediated by short-term SBP variability.

  11. Continuous Passive Motion Provides Good Pain Control in Patients with Adhesive Capsulitis

    ERIC Educational Resources Information Center

    Dundar, Umit; Toktas, Hasan; Cakir, Tuncay; Evcik, Deniz; Kavuncu, Vural

    2009-01-01

    Painful stiffening of the shoulder, "frozen shoulder" is a common cause of shoulder pain and disability. Continuous passive motion (CPM) is an established method of preventing joint stiffness and of overcoming it. A randomized, comparative prospective clinical trial was planned to compare the early response with different rehabilitation…

  12. Effect of spine motion on mobility in quadruped running

    NASA Astrophysics Data System (ADS)

    Chen, Dongliang; Liu, Qi; Dong, Litao; Wang, Hong; Zhang, Qun

    2014-11-01

    Most of current running quadruped robots have similar construction: a stiff body and four compliant legs. Many researches have indicated that the stiff body without spine motion is a main factor in limitation of robots' mobility. Therefore, investigating spine motion is very important to build robots with better mobility. A planar quadruped robot is designed based on cheetahs' morphology. There is a spinal driving joint in the body of the robot. When the spinal driving joint acts, the robot has spine motion; otherwise, the robot has not spine motion. Six group prototype experiments with the robot are carried out to study the effect of spine motion on mobility. In each group, there are two comparative experiments: the spinal driving joint acts in one experiment but does not in the other experiment. The results of the prototype experiments indicate that the average speeds of the robot with spine motion are 8.7%-15.9% larger than those of the robot without spine motion. Furthermore, a simplified sagittal plane model of quadruped mammals is introduced. The simplified model also has a spinal driving joint. Using a similar process as the prototype experiments, six group simulation experiments with the simplified model are conducted. The results of the simulation experiments show that the maximum rear leg horizontal thrusts of the simplified mode with spine motion are 68.2%-71.3% larger than those of the simplified mode without spine motion. Hence, it is found that spine motion can increase the average running speed and the intrinsic reason of speed increase is the improvement of the maximum rear leg horizontal thrust.

  13. Multifunctional Lattices with Low Thermal Expansion and Low Thermal Conductivity

    NASA Astrophysics Data System (ADS)

    Xu, Hang; Liu, Lu; Pasini, Damiano

    Systems in space are vulnerable to large temperature changes when travelling into and out of the Earth's shadow. Variations in temperature can lead to undesired geometric changes in susceptible applications requiring very fine precision. In addition, temperature-sensitive electronic equipment hosted in a satellite needs adequate thermal-control to guarantee a moderate ambient temperature. To address these specifications, materials with low coefficient of thermal expansion (CTE) and low coefficient of thermal conductivity (CTC) over a wide range of temperatures are often sought, especially for bearing components in satellites. Besides low CTE and low CTC, these materials should also provide desirable stiffness, strength and extraordinarily low mass. This work presents ultralightweight bi-material lattices with tunable CTE and CTC, besides high stiffness and strength. We show that the compensation of the thermal expansion and joint rotation at the lattice joints can be used as an effective strategy to tailor thermomechanical performance. Proof-of-concept lattices are fabricated from Al and Ti alloy sheets via a simple snap-fit technique and vacuum brazing, and their CTE and CTC are assessed via a combination of experiments and theory. Corresponding Author.

  14. Global Gene Expression Differences in Joints of Mice with Divergent Post Traumatic Osteoarthritis Phenotypes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kibui, J.

    Osteoarthritis (OA) is a debilitating joint disease characterized by cartilage degradation which prompts pain, stiffness and swelling. Contributing factors include age, genetics, obesity, injury and overuse of joints. OA is defined by an acute phase and a chronic phase whereby inflammation and degeneration of articular cartilage and other tissues is followed by joint pain and limited mobility. Patients remain asymptomatic until substantial joint damage has occurred and therefore rely on long term surgical joint replacement and pain management as their sole treatment options. For this reason, there is an increasing need to identify early stage osteoarthritis biomarkers. Our study aimedmore » to identify and characterize gene expression variances in 3 different mouse strains (STR/ort, C57BL/6 and MRL/MpJ) with different susceptibility to post traumatic osteoarthritis (PTOA). Through RNA sequence analysis of whole knee joint RNA, we identified differentially expressed genes associated with the initial stages of PTOA in relation to mice with divergent phenotypes. These results will help elucidate potential mechanisms responsible for PTOA outcomes.« less

  15. Equilibrium-point control of human elbow-joint movement under isometric environment by using multichannel functional electrical stimulation

    PubMed Central

    Matsui, Kazuhiro; Hishii, Yasuo; Maegaki, Kazuya; Yamashita, Yuto; Uemura, Mitsunori; Hirai, Hiroaki; Miyazaki, Fumio

    2014-01-01

    Functional electrical stimulation (FES) is considered an effective technique for aiding quadriplegic persons. However, the human musculoskeletal system has highly non-linearity and redundancy. It is thus difficult to stably and accurately control limbs using FES. In this paper, we propose a simple FES method that is consistent with the motion-control mechanism observed in humans. We focus on joint motion by a pair of agonist-antagonist muscles of the musculoskeletal system, and define the “electrical agonist-antagonist muscle ratio (EAA ratio)” and “electrical agonist-antagonist muscle activity (EAA activity)” in light of the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, respectively, to extract the equilibrium point and joint stiffness from electromyography (EMG) signals. These notions, the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, are based on the hypothesis that the equilibrium point and stiffness of the agonist-antagonist motion system are controlled by the central nervous system. We derived the transfer function between the input EAA ratio and force output of the end-point. We performed some experiments in an isometric environment using six subjects. This transfer-function model is expressed as a cascade-coupled dead time element and a second-order system. High-speed, high-precision, smooth control of the hand force were achieved through the agonist-antagonist muscle stimulation pattern determined by this transfer function model. PMID:24987326

  16. Equilibrium-point control of human elbow-joint movement under isometric environment by using multichannel functional electrical stimulation.

    PubMed

    Matsui, Kazuhiro; Hishii, Yasuo; Maegaki, Kazuya; Yamashita, Yuto; Uemura, Mitsunori; Hirai, Hiroaki; Miyazaki, Fumio

    2014-01-01

    Functional electrical stimulation (FES) is considered an effective technique for aiding quadriplegic persons. However, the human musculoskeletal system has highly non-linearity and redundancy. It is thus difficult to stably and accurately control limbs using FES. In this paper, we propose a simple FES method that is consistent with the motion-control mechanism observed in humans. We focus on joint motion by a pair of agonist-antagonist muscles of the musculoskeletal system, and define the "electrical agonist-antagonist muscle ratio (EAA ratio)" and "electrical agonist-antagonist muscle activity (EAA activity)" in light of the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, respectively, to extract the equilibrium point and joint stiffness from electromyography (EMG) signals. These notions, the agonist-antagonist muscle ratio and agonist-antagonist muscle activity, are based on the hypothesis that the equilibrium point and stiffness of the agonist-antagonist motion system are controlled by the central nervous system. We derived the transfer function between the input EAA ratio and force output of the end-point. We performed some experiments in an isometric environment using six subjects. This transfer-function model is expressed as a cascade-coupled dead time element and a second-order system. High-speed, high-precision, smooth control of the hand force were achieved through the agonist-antagonist muscle stimulation pattern determined by this transfer function model.

  17. Nonlinear Analysis of Bonded Composite Single-LAP Joints

    NASA Technical Reports Server (NTRS)

    Oterkus, E.; Barut, A.; Madenci, E.; Smeltzer, S. S.; Ambur, D. R.

    2004-01-01

    This study presents a semi-analytical solution method to analyze the geometrically nonlinear response of bonded composite single-lap joints with tapered adherend edges under uniaxial tension. The solution method provides the transverse shear and normal stresses in the adhesive and in-plane stress resultants and bending moments in the adherends. The method utilizes the principle of virtual work in conjunction with von Karman s nonlinear plate theory to model the adherends and the shear lag model to represent the kinematics of the thin adhesive layer between the adherends. Furthermore, the method accounts for the bilinear elastic material behavior of the adhesive while maintaining a linear stress-strain relationship in the adherends. In order to account for the stiffness changes due to thickness variation of the adherends along the tapered edges, their in-plane and bending stiffness matrices are varied as a function of thickness along the tapered region. The combination of these complexities results in a system of nonlinear governing equilibrium equations. This approach represents a computationally efficient alternative to finite element method. Comparisons are made with corresponding results obtained from finite-element analysis. The results confirm the validity of the solution method. The numerical results present the effects of taper angle, adherend overlap length, and the bilinear adhesive material on the stress fields in the adherends, as well as the adhesive, of a single-lap joint

  18. Habitual Minimalist Shod Running Biomechanics and the Acute Response to Running Barefoot.

    PubMed

    Tam, Nicholas; Darragh, Ian A J; Divekar, Nikhil V; Lamberts, Robert P

    2017-09-01

    The aim of the study was to determine whether habitual minimalist shoe runners present with purported favorable running biomechanithat reduce running injury risk such as initial loading rate. Eighteen minimalist and 16 traditionally cushioned shod runners were assessed when running both in their preferred training shoe and barefoot. Ankle and knee joint kinetics and kinematics, initial rate of loading, and footstrike angle were measured. Sagittal ankle and knee joint stiffness were also calculated. Results of a two-factor ANOVA presented no group difference in initial rate of loading when participants were running either shod or barefoot; however, initial loading rate increased for both groups when running barefoot (p=0.008). Differences in footstrike angle were observed between groups when running shod, but not when barefoot (minimalist:8.71±8.99 vs. traditional: 17.32±11.48 degrees, p=0.002). Lower ankle joint stiffness was found in both groups when running barefoot (p=0.025). These findings illustrate that risk factors for injury potentially differ between the two groups. Shoe construction differences do change mechanical demands, however, once habituated to the demands of a given shoe condition, certain acute favorable or unfavorable responses may be moderated. The purported benefits of minimalist running shoes in mimicking habitual barefoot running is questioned, and risk of injury may not be attenuated. © Georg Thieme Verlag KG Stuttgart · New York.

  19. A structurally adaptive space crane concept for assembling space systems on orbit

    NASA Technical Reports Server (NTRS)

    Dorsey, John T.; Sutter, Thomas R.; Wu, K. C.

    1992-01-01

    A space crane concept is presented which is based on erectable truss hardware to achieve high stiffness and low mass booms and articulating-truss joints which can be assembled on orbit. The hardware is characterized by linear load-deflection response and is structurally predictable. The crane can be reconfigured into different geometries to meet future assembly requirements. Articulating-truss joint concepts with significantly different geometries are analyzed and found to have similar static and dynamic performance, which indicates that criteria other than structural and kinematic performance can be used to select a joint. Passive damping and an open-loop preshaped command input technique greatly enhance the structural damping in the space crane and may preclude the need for an active vibrations suppression system.

  20. Mechanical Impedance of the Non-loaded Lower Leg with Relaxed Muscles in the Transverse Plane

    PubMed Central

    Ficanha, Evandro Maicon; Ribeiro, Guilherme Aramizo; Rastgaar, Mohammad

    2015-01-01

    This paper describes the protocols and results of the experiments for the estimation of the mechanical impedance of the humans’ lower leg in the External–Internal direction in the transverse plane under non-load bearing condition and with relaxed muscles. The objectives of the estimation of the lower leg’s mechanical impedance are to facilitate the design of passive and active prostheses with mechanical characteristics similar to the humans’ lower leg, and to define a reference that can be compared to the values from the patients suffering from spasticity. The experiments were performed with 10 unimpaired male subjects using a lower extremity rehabilitation robot (Anklebot, Interactive Motion Technologies, Inc.) capable of applying torque perturbations to the foot. The subjects were in a seated position, and the Anklebot recorded the applied torques and the resulting angular movement of the lower leg. In this configuration, the recorded dynamics are due mainly to the rotations of the ankle’s talocrural and the subtalar joints, and any contribution of the tibiofibular joints and knee joint. The dynamic mechanical impedance of the lower leg was estimated in the frequency domain with an average coherence of 0.92 within the frequency range of 0–30 Hz, showing a linear correlation between the displacement and the torques within this frequency range under the conditions of the experiment. The mean magnitude of the stiffness of the lower leg (the impedance magnitude averaged in the range of 0–1 Hz) was determined as 4.9 ± 0.74 Nm/rad. The direct estimation of the quasi-static stiffness of the lower leg results in the mean value of 5.8 ± 0.81 Nm/rad. An analysis of variance shows that the estimated values for the stiffness from the two experiments are not statistically different. PMID:26697424

  1. Changes in biomechanical properties of glenohumeral joint capsules with adhesive capsulitis by repeated capsule-preserving hydraulic distensions with saline solution and corticosteroid.

    PubMed

    Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan

    2012-12-01

    To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P < .05 for all). Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  2. Dynamic response characteristics of steel portal frames having semi-rigid joints under sinusoidal wave excitation

    NASA Astrophysics Data System (ADS)

    Bhatti, Abdul Qadir

    2017-12-01

    To demonstrate the characteristics of the nonlinear response of steel frames, an elastic dynamic response analysis of the semi-rigid frame is performed under the harmonic wave. The semi-rigid contact is represented by the alternating spring which is given stiffness by a three-parameter energy model which approaches the hysterical curve by hardening model. The properties of spectra and hysteric curves are presented. This study shows that (1) the greater the acceleration input capacitance the smaller the instant connection capability and the smaller is the response. (2) However, by allowing an extreme increase in capacitance input acceleration, response spectra can be increased as the contact stiffness results near zero.

  3. Relationship between neck circumference, insulin resistance and arterial stiffness in overweight and obese subjects.

    PubMed

    Fantin, Francesco; Comellato, Gabriele; Rossi, Andrea P; Grison, Elisa; Zoico, Elena; Mazzali, Gloria; Zamboni, Mauro

    2017-09-01

    Background Only a few studies have investigated the relationship between neck circumference and cardiometabolic risk. The aim of this study was to assess the relationships between neck circumference, waist circumference, metabolic variables and arterial stiffness in a group of overweight and obese subjects evaluating a possible independent role of neck circumference in determining arterial stiffness. Methods and results We studied 95 subjects (53 women) with an age range of 20-77 years and body mass index range from 25.69 to 47.04 kg/m 2 . In each subject we evaluated body mass index, waist, hip and neck circumference, systolic and diastolic blood pressure, insulin, fasting glucose, cholesterol, low-density lipoprotein and high-density lipoprotein cholesterol and triglycerides. Arterial stiffness was assessed by carotid-femoral pulse wave velocity (PWVcf) and carotid-radial pulse wave velocity (PWVcr). Both PWVcf and PWVcr were higher in subjects with high values of neck circumference compared with subjects with normal values of neck circumference. Subjects with high values of neck circumference and abdominal obesity presented higher values of mean arterial pressure, PWVcr and homeostasis model assessment (HOMA) index and lower values of high-density lipoprotein than subjects with only abdominal obesity. Two models of stepwise multiple regression were performed in order to evaluate the combined effect of independent variables on arterial stiffness. In the first model PWVcf was considered a dependent variable, and age, gender, systolic blood pressure, triglycerides, high-density lipoprotein cholesterol, waist circumference, neck circumference, HOMA index and the use of anti-hypertensive medications were considered independent variables. Age, systolic blood pressure, triglycerides and waist circumference were significant predictors of PWVcf, explaining 65% of its variance. In the second model, in which PWVcr was considered a dependent variable, neck circumference and gender were significant predictors of PWVcr, explaining 24% of its variance. Conclusions These findings emphasise the need to measure not only waist but even neck circumference to better stratify and identify individuals at increased cardiometabolic risk, as upper-body subcutaneous fat is a novel, easily measured fat depot.

  4. Identifying the control structure of multijoint coordination during pistol shooting.

    PubMed

    Scholz, J P; Schöner, G; Latash, M L

    2000-12-01

    The question of degrees of freedom in the control of multijoint movement is posed as the problem of discovering how the motor control system constrains the many possible combinations of joint postures to stabilize task-dependent essential variables. Success at a task can be achieved, in principle, by always adopting a particular joint combination. In contrast, we propose a more selective control strategy: variations of the joint configuration that leave the values of essential task variables unchanged are predicted to be less controlled (i.e., stabilized to a lesser degree) than joint configuration changes that shift the values of the task variables. Our experimental task involved shooting with a laser pistol at a target under four conditions. The seven joint angles of the arm were obtained from the recorded positions of markers on the limb segments. The joint configurations observed at each point in normalized time were analyzed with respect to trial-to-trial variability. Different hypotheses about relevant task variables were used to define sets of joint configurations ("uncontrolled manifolds" or UCMs) that, if realized, would leave essential task variables unchanged. The variability of joint configurations was decomposed into components lying parallel to those sets and components lying in their complement. The orientation of the gun's barrel relative to a vector pointing from the gun to the target was the task variable most successful at showing a difference between the two components of joint variability. This variable determines success at the task. Throughout the movement, not only while the gun was pointing at the target, fluctuations of joint configuration that affected this variable were much reduced compared with fluctuations that did not affect this variable. The UCM principle applied to relative gun orientation thus captures the structure of the motor control system across different parts of joint configuration space as the movement evolves in time. This suggests a specific control strategy in which changes of joint configuration that are irrelevant to success at the task are selectively released from control. By contrast, constraints representing an invariant spatial position of the gun or of the arm's center of mass structured joint configuration variability in the early and mid-portion of the movement trajectory, but not at the time of shooting. This specific control strategy is not trivial, because a target can be hit successfully also by controlling irrelevant directions in joint space equally to relevant ones. The results indicate that the method can be successfully used to determine the structure of coordination in joint space that underlies the control of the essential variables for a given task.

  5. The effect of ankle foot orthosis stiffness on the energy cost of walking: a simulation study.

    PubMed

    Bregman, D J J; van der Krogt, M M; de Groot, V; Harlaar, J; Wisse, M; Collins, S H

    2011-11-01

    In stroke and multiple sclerosis patients, gait is frequently hampered by a reduced ability to push-off with the ankle caused by weakness of the plantar-flexor muscles. To enhance ankle push-off and to decrease the high energy cost of walking, spring-like carbon-composite Ankle Foot Orthoses are frequently prescribed. However, it is unknown what Ankle Foot Orthoses stiffness should be used to obtain the most efficient gait. The aim of this simulation study was to gain insights into the effect of variation in Ankle Foot Orthosis stiffness on the amount of energy stored in the Ankle Foot Orthosis and the energy cost of walking. We developed a two-dimensional forward-dynamic walking model with a passive spring at the ankle representing the Ankle Foot Orthosis and two constant torques at the hip for propulsion. We varied Ankle Foot Orthosis stiffness while keeping speed and step length constant. We found an optimal stiffness, at which the energy delivered at the hip joint was minimal. Energy cost decreased with increasing energy storage in the ankle foot orthosis, but the most efficient gait did not occur with maximal energy storage. With maximum storage, push-off occurred too late to reduce the impact of the contralateral leg with the floor. Maximum return prior to foot strike was also suboptimal, as push-off occurred too early and its effects were subsequently counteracted by gravity. The optimal Ankle Foot Orthosis stiffness resulted in significant push-off timed just prior to foot strike and led to greater ankle plantar-flexion velocity just before contralateral foot strike. Our results suggest that patient energy cost might be reduced by the proper choice of Ankle Foot Orthosis stiffness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. The Relationship Between Shoulder Stiffness and Rotator Cuff Healing: A Study of 1,533 Consecutive Arthroscopic Rotator Cuff Repairs.

    PubMed

    McNamara, William J; Lam, Patrick H; Murrell, George A C

    2016-11-16

    Retear and stiffness are not uncommon outcomes of rotator cuff repair. The purpose of this study was to evaluate the relationship between rotator cuff repair healing and shoulder stiffness. A total of 1,533 consecutive shoulders had an arthroscopic rotator cuff repair by a single surgeon. Patients assessed their shoulder stiffness using a Likert scale preoperatively and at 1, 6, 12, and 24 weeks (6 months) postoperatively, and examiners evaluated passive range of motion preoperatively and at 6, 12, and 24 weeks postoperatively. Repair integrity was determined by ultrasound evaluation at 6 months. After rotator cuff repair, there was an overall significant loss of patient-ranked and examiner-assessed shoulder motion at 6 weeks compared with preoperative measurements (p < 0.0001), a partial recovery at 12 weeks, and a full recovery at 24 weeks. Shoulders that were stiff before surgery were more likely to be stiff at 6, 12, and, to a lesser extent, 24 weeks after surgery (r = 0.10 to 0.31; p < 0.0001). A stiffer shoulder at 6 and 12 weeks (but not 24 weeks) postoperatively correlated with better rotator cuff integrity at 6 months postoperatively (r = 0.11 to 0.18; p < 0.001). The retear rate of patients with ≤20° of external rotation at 6 weeks postoperatively was 7%, while the retear rate of patients with >20° of external rotation at 6 weeks was 15% (p < 0.001). In patients who developed stiffness after surgery, a rotator cuff repair was more likely to heal. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  7. Net ankle quasi-stiffness is influenced by walking speed but not age for older adult women.

    PubMed

    Collins, John D; Arch, Elisa S; Crenshaw, Jeremy R; Bernhardt, Kathie A; Khosla, Sundeep; Amin, Shreyasee; Kaufman, Kenton R

    2018-03-26

    Insufficient plantar flexor resistance due to plantar flexor weakness, an impairment common in patient populations, causes substantial gait deficits. The bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) has the capacity to replace lost plantar flexor resistance. Many patients who are prescribed PD-AFOs are older adults. While PD-AFO bending stiffness should be customized for patients, a method to objectively prescribe this stiffness does not exist. Quantifying natural plantar flexor resistance during non-pathological gait could provide a reference value for objectively prescribing PD-AFO bending stiffness. This study investigated the effect of age on plantar flexor resistance in 113 participants above the age of 65 years. We did so while also considering the confounding influence of gait speed, an aspect known to be reduced with old age. Ambulatory, community-dwelling older adult women (ages 65-91 years) with no current or recent lower-extremity injuries or surgeries underwent an instrumented gait analysis at a self-selected speed. Plantar flexor resistance was quantified via net ankle quasi-stiffness (NAS) defined as the slope of ankle joint moment-angle curve during late stance. showed that NAS was not significantly influenced by age (r = -0.11, p = 0.12), and that the confounding factor of walking speed had a significant, positive relationship with NAS (r = 0.59, p < 0.001). By determining that gait speed, not age, is related to NAS in older adults, this study represents the initial step towards objectively prescribing PD-AFO bending stiffness to achieve a targeted gait speed for older adults with plantar flexor weakness. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Defining the mechanical properties of a spring-hinged ankle foot orthosis to assess its potential use in children with spastic cerebral palsy.

    PubMed

    Kerkum, Yvette L; Brehm, Merel-Anne; Buizer, Annemieke I; van den Noort, Josien C; Becher, Jules G; Harlaar, Jaap

    2014-12-01

    A rigid ventral shelf ankle foot orthosis (AFO) may improve gait in children with spastic cerebral palsy (SCP) whose gait is characterized by excessive knee flexion in stance. However, these AFOs can also impede ankle range of motion (ROM) and thereby inhibit push-off power. A more spring-like AFO can enhance push-off and may potentially reduce walking energy cost. The recent development of an adjustable spring-hinged AFO now allows adjustment of AFO stiffness, enabling tuning toward optimal gait performance. This study aims to quantify the mechanical properties of this spring-hinged AFO for each of its springs and settings. Using an AFO stiffness tester, two AFO hinges and their accompanying springs were measured. The springs showed a stiffness range of 0.01-1.82 N · m · deg(-1). The moment-threshold increased with increasing stiffness (1.13-12.1 N · m), while ROM decreased (4.91-16.5°). Energy was returned by all springs (11.5-116.3 J). These results suggest that the two stiffest available springs should improve joint kinematics and enhance push-off in children with SCP walking with excessive knee flexion.

  9. Spinal Stiffness in Prone and Upright Postures During 0-1.8 g Induced by Parabolic Flight.

    PubMed

    Swanenburg, Jaap; Meier, Michael L; Langenfeld, Anke; Schweinhardt, Petra; Humphreys, B Kim

    2018-06-01

    The purpose of this study was to analyze posterior-to-anterior spinal stiffness in Earth, hyper-, and microgravity conditions during both prone and upright postures. During parabolic flight, the spinal stiffness of the L3 vertebra of a healthy 37-yr-old man was measured in normal Earth gravity (1.0 g), hypergravity (1.8 g), and microgravity (0.0 g) conditions induced in the prone and upright positions. Differences in spinal stiffness were significant across all three gravity conditions in the prone and upright positions. Most effect sizes were large; however, in the upright posture, the effect size between Earth gravity and microgravity was medium. Significant differences in spinal stiffness between the prone and upright positions were found during Earth gravity and hypergravity conditions. No difference was found between the two postures during microgravity conditions. Based on repeated measurements of a single individual, our results showed detectable changes in posterior-to-anterior spinal stiffness. Spinal stiffness increased during microgravity and decreased during hypergravity conditions. In microgravity conditions, posture did not impact spinal stiffness. More data on spinal stiffness in variable gravitational conditions is needed to confirm these results.Swanenburg J, Meier ML, Langenfeld A, Schweinhardt P, Humphreys BK. Spinal stiffness in prone and upright postures during 0-1.8 g induced by parabolic flight. Aerosp Med Hum Perform. 2018; 89(6):563-567.

  10. Propulsive performance of pitching foils with variable chordwise flexibility

    NASA Astrophysics Data System (ADS)

    Zeyghami, Samane; Moored, Keith; Lehigh University Team

    2017-11-01

    Many swimming and flying animals propel themselves efficiently through water by oscillating flexible fins. These fins are not homogeneously flexible, but instead their flexural stiffness varies along their chord and span. Here we seek to evaluate the effect stiffness profile on the propulsive performance of pitching foils. Stiffness profile characterizes the variation in the local fin stiffness along the chord. To this aim, we developed a low order model of a functionally-graded material where the chordwise flexibility is modeled by two torsional springs along the chordline and the stiffness and location of the springs can be varied arbitrarily. The torsional spring structural model is then strongly coupled to a boundary element fluid model to simulate the fluid-structure interactions. Keeping the leading edge kinematics unchanged, we alter the stiffness profile of the foil and allow it to swim freely in response to the resulting hydrodynamic forces. We then detail the dependency of the hydrodynamic performance and the wake structure to the variations in the local structural properties of the foil.

  11. Mechanical stiffness of TMJ condylar cartilage increases after artificial aging by ribose.

    PubMed

    Mirahmadi, Fereshteh; Koolstra, Jan Harm; Lobbezoo, Frank; van Lenthe, G Harry; Ghazanfari, Samaneh; Snabel, Jessica; Stoop, Reinout; Everts, Vincent

    2018-03-01

    Aging is accompanied by a series of changes in mature tissues that influence their properties and functions. Collagen, as one of the main extracellular components of cartilage, becomes highly crosslinked during aging. In this study, the aim was to examine whether a correlation exists between collagen crosslinking induced by artificial aging and mechanical properties of the temporomandibular joint (TMJ) condyle. To evaluate this hypothesis, collagen crosslinks were induced using ribose incubation. Porcine TMJ condyles were incubated for 7 days with different concentrations of ribose. The compressive modulus and stiffness ratio (incubated versus control) was determined after loading. Glycosaminoglycan and collagen content, and the number of crosslinks were analyzed. Tissue structure was visualized by microscopy using different staining methods. Concomitant with an increasing concentration of ribose, an increase of collagen crosslinks was found. The number of crosslinks increased almost 50 fold after incubation with the highest concentration of ribose. Simultaneously, the stiffness ratio of the samples showed a significant increase after incubation with the ribose. Pearson correlation analyses showed a significant positive correlation between the overall stiffness ratio and the crosslink level; the higher the number of crosslinks the higher the stiffness. The present model, in which ribose was used to mimic certain aspects of age-related changes, can be employed as an in vitro model to study age-related mechanical changes in the TMJ condyle. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Metatarsal Osteotomies: Complications.

    PubMed

    Reddy, Veerabhadra Babu

    2018-03-01

    Metatarsal osteotomies can be divided into proximal and distal. The proximal osteotomies, such as the oblique, segmental, set cut, and Barouk-Rippstein-Toullec (BRT) osteotomy, all provide the ability to significantly change the position of the metatarsal head without violating the joint. These osteotomies, however, have a high rate of nonunion when done without internal fixation and can lead to transfer metatarsalgia when done without regard to the parabola of metatarsal head position. Distal osteotomies such as the Weil and Helal offer superior healing but have an increased incidence of recurrent metatarsalgia, joint stiffness, and floating toe. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Janus Kinase Inhibitors for the Treatment of Rheumatoid Arthritis.

    PubMed

    Turan, Senir; Walker, Scot

    2017-11-01

    Rheumatoid arthritis (RA) is a disease where the immune system attacks the linings of the joints, resulting in joint pain, stiffness, swelling, and destruction. Although many products are available for the treatment of RA, limitations such as adverse reactions and tolerance greatly affect adherence. Many of the current biologic disease-modifying antirheumatic drugs on the market are injectables, leaving a void to be filled for a product that can be taken orally. The most advanced of these approaches, the Janus kinase (JAK) inhibitors, are oral drugs that have not only made a breakthrough in RA, but also other skin conditions.

  14. Maps and models of density and stiffness within individual Douglas-fir trees

    Treesearch

    Christine L. Todoroki; Eini C. Lowell; Dennis P. Dykstra; David G. Briggs

    2012-01-01

    Spatial maps of density and stiffness patterns within individual trees were developed using two methods: (1) measured wood properties of veneer sheets; and (2) mixed effects models, to test the hypothesis that within-tree patterns could be predicted from easily measurable tree variables (height, taper, breast-height diameter, and acoustic velocity). Sample trees...

  15. Modeling Anisotropic Elastic Wave Propagation in Jointed Rock Masses

    NASA Astrophysics Data System (ADS)

    Hurley, R.; Vorobiev, O.; Ezzedine, S. M.; Antoun, T.

    2016-12-01

    We present a numerical approach for determining the anisotropic stiffness of materials with nonlinearly-compliant joints capable of sliding. The proposed method extends existing ones for upscaling the behavior of a medium with open cracks and inclusions to cases relevant to natural fractured and jointed rocks, where nonlinearly-compliant joints can undergo plastic slip. The method deviates from existing techniques by incorporating the friction and closure states of the joints, and recovers an anisotropic elastic form in the small-strain limit when joints are not sliding. We present the mathematical formulation of our method and use Representative Volume Element (RVE) simulations to evaluate its accuracy for joint sets with varying complexity. We then apply the formulation to determine anisotropic elastic constants of jointed granite found at the Nevada Nuclear Security Site (NNSS) where the Source Physics Experiments (SPE), a campaign of underground chemical explosions, are performed. Finally, we discuss the implementation of our numerical approach in a massively parallel Lagrangian code Geodyn-L and its use for studying wave propagation from underground explosions. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  16. Numerical Investigation of the Dynamic Properties of Intermittent Jointed Rock Models Subjected to Cyclic Uniaxial Compression

    NASA Astrophysics Data System (ADS)

    Liu, Yi; Dai, Feng; Zhao, Tao; Xu, Nu-wen

    2017-01-01

    Intermittent jointed rocks, which exist in a myriad of engineering projects, are extraordinarily susceptible to cyclic loadings. Understanding the dynamic fatigue properties of jointed rocks is necessary for evaluating the stability of rock engineering structures. This study numerically investigated the influences of cyclic loading conditions (i.e., frequency, maximum stress and amplitude) and joint geometric configurations (i.e., dip angle, persistency and interspace) on the dynamic fatigue mechanisms of jointed rock models. A reduction model of stiffness and strength was first proposed, and then, sixteen cyclic uniaxial loading tests with distinct loading parameters and joint geometries were simulated. Our results indicate that the reduction model can effectively reproduce the hysteresis loops and the accumulative plastic deformation of jointed rocks in the cyclic process. Both the loading parameters and the joint geometries significantly affect the dynamic properties, including the irreversible strain, damage evolution, dynamic residual strength and fatigue life. Three failure modes of jointed rocks, which are principally controlled by joint geometries, occur in the simulations: splitting failure through the entire rock sample, sliding failure along joint planes and mixed failure, which are principally controlled by joint geometries. Furthermore, the progressive failure processes of the jointed rock samples are numerically observed, and the different loading stages can be distinguished by the relationship between the number of broken bonds and the axial stress.

  17. Adaptive Postural Control for Joint Immobilization during Multitask Performance

    PubMed Central

    Hsu, Wei-Li

    2014-01-01

    Motor abundance is an essential feature of adaptive control. The range of joint combinations enabled by motor abundance provides the body with the necessary freedom to adopt different positions, configurations, and movements that allow for exploratory postural behavior. This study investigated the adaptation of postural control to joint immobilization during multi-task performance. Twelve healthy volunteers (6 males and 6 females; 21–29 yr) without any known neurological deficits, musculoskeletal conditions, or balance disorders participated in this study. The participants executed a targeting task, alone or combined with a ball-balancing task, while standing with free or restricted joint motions. The effects of joint configuration variability on center of mass (COM) stability were examined using uncontrolled manifold (UCM) analysis. The UCM method separates joint variability into two components: the first is consistent with the use of motor abundance, which does not affect COM position (VUCM); the second leads to COM position variability (VORT). The analysis showed that joints were coordinated such that their variability had a minimal effect on COM position. However, the component of joint variability that reflects the use of motor abundance to stabilize COM (VUCM) was significant decreased when the participants performed the combined task with immobilized joints. The component of joint variability that leads to COM variability (VORT) tended to increase with a reduction in joint degrees of freedom. The results suggested that joint immobilization increases the difficulty of stabilizing COM when multiple tasks are performed simultaneously. These findings are important for developing rehabilitation approaches for patients with limited joint movements. PMID:25329477

  18. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint.

    PubMed

    Vedrine, Bertrand

    2017-04-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation.

  19. Applied Joint-Space Torque and Stiffness Control of Tendon-Driven Fingers

    NASA Technical Reports Server (NTRS)

    Abdallah, Muhammad E.; Platt, Robert, Jr.; Wampler, Charles W.; Hargrave, Brian

    2010-01-01

    Existing tendon-driven fingers have applied force control through independent tension controllers on each tendon, i.e. in the tendon-space. The coupled kinematics of the tendons, however, cause such controllers to exhibit a transient coupling in their response. This problem can be resolved by alternatively framing the controllers in the joint-space of the manipulator. This work presents a joint-space torque control law that demonstrates both a decoupled and significantly faster response than an equivalent tendon-space formulation. The law also demonstrates greater speed and robustness than comparable PI controllers. In addition, a tension distribution algorithm is presented here to allocate forces from the joints to the tendons. It allocates the tensions so that they satisfy both an upper and lower bound, and it does so without requiring linear programming or open-ended iterations. The control law and tension distribution algorithm are implemented on the robotic hand of Robonaut-2.

  20. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint

    PubMed Central

    Vedrine, Bertrand

    2017-01-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation. PMID:28373726

  1. Nonlinear Modeling of Joint Dominated Structures

    NASA Technical Reports Server (NTRS)

    Chapman, J. M.

    1990-01-01

    The development and verification of an accurate structural model of the nonlinear joint-dominated NASA Langley Mini-Mast truss are described. The approach is to characterize the structural behavior of the Mini-Mast joints and struts using a test configuration that can directly measure the struts' overall stiffness and damping properties, incorporate this data into the structural model using the residual force technique, and then compare the predicted response with empirical data taken by NASA/LaRC during the modal survey tests of the Mini-Mast. A new testing technique, referred to as 'link' testing, was developed and used to test prototype struts of the Mini-Masts. Appreciable nonlinearities including the free-play and hysteresis were demonstrated. Since static and dynamic tests performed on the Mini-Mast also exhibited behavior consistent with joints having free-play and hysteresis, nonlinear models of the Mini-Mast were constructed and analyzed. The Residual Force Technique was used to analyze the nonlinear model of the Mini-Mast having joint free-play and hysteresis.

  2. Reliability formulation for the strength and fire endurance of glued-laminated beams

    Treesearch

    D. A. Bender

    A model was developed for predicting the statistical distribution of glued-laminated beam strength and stiffness under normal temperature conditions using available long span modulus of elasticity data, end joint tension test data, and tensile strength data for laminating-grade lumber. The beam strength model predictions compared favorably with test data for glued-...

  3. Influence of Maturation Status on Eccentric Exercise-Induced Muscle Damage and the Repeated Bout Effect in Females

    PubMed Central

    Lin, Ming-Ju; Nosaka, Kazunori; Ho, Chih-Chiao; Chen, Hsin-Lian; Tseng, Kuo-Wei; Ratel, Sébastien; Chen, Trevor Chung-Ching

    2018-01-01

    This study compared changes in indirect muscle damage markers, proprioception and arterial stiffness after elbow flexor eccentric exercise between pre-pubescent (9–10 y), pubescent (14–15 y), and post-pubescent (20–24 y) healthy, untrained females (n = 13/group). The maturation of the participants was confirmed by the hand bone age. All participants performed two bouts of 30 sub-maximal eccentric contractions (EC1, EC2) using a dumbbell set at 60% of pre-exercise maximal voluntary isometric elbow flexion strength at 90°. Changes in maximal voluntary concentric contraction (MVC) torque, muscle soreness (SOR), plasma creatine kinase activity, proprioception (position sense, joint reaction angle) and arterial stiffness (carotid-femoral pulse-wave velocity: cfPWV) before to 5 days after EC1 and EC2 were compared among groups by a mixed-design two-way ANOVA. Pre-exercise MVC torque and cfPWV were smaller (P < 0.05) for the pre-pubescent (MVC: 10.0 ± 0.9 Nm, cfPWV: 903 ± 60 cm/s) and the pubescent (14.3 ± 1.1 Nm, 967 ± 61 cm/s) than the post-pubescent (19.1 ± 1.4 Nm, 1,103 ± 73 cm/s). Changes in all variables after EC1 were smaller (P < 0.05) for the pre-pubescent (e.g., MVC at 1 d post-exercise: −10 ± 6%, peak SOR: 5 ± 2 mm) than the pubescent (−15 ± 9%, 12 ± 6 mm) and the post-pubescent (−25 ± 7%, 19 ± 13 mm). After EC2, changes in all variables were smaller (P < 0.05) than those after EC1 for all groups (e.g., MVC at 1 d post-exercise, pre-pubescent: −4 ± 6%, pubescent: −9 ± 4%, post-pubescent: −14 ± 5%; peak SOR: 3 ± 2, 7 ± 3, 11 ± 6 mm), but the magnitude of the repeated bout effect was not different (P > 0.05) among the groups. These results show that the extents of muscle damage, and proprioception and arterial stiffness changes after eccentric exercise are greater at later stages of maturation, but the repeated bout effect is not affected by maturation. PMID:29354073

  4. Unintentional Changes in the Apparent Stiffness of the Multi-Joint Limb

    PubMed Central

    Zhou, Tao; Zatsiorsky, Vladimir M.; Latash, Mark L.

    2015-01-01

    We explored the phenomenon of unintentional changes in the apparent stiffness of the human arm produced by transient changes in the external force. The subjects performed a positional task against a constant baseline force and were instructed not to react to changes in the force. A HapticMaster robot produced a smooth force increase (a perturbation) leading to a hand movement, followed by a dwell time. No visible hand drift was observed during the dwell time. After the robot force dropped to its initial baseline value, the hand moved towards the initial position but stopped short of it. Small perturbations were applied at different time intervals along different directions during the dwell time. Arm apparent stiffness distribution in a horizontal plane was approximated with an ellipse. The apparent stiffness magnitude along the main axis of the ellipse showed a non-monotonic increase with dwell time while the apparent stiffness along the minor axis did not change significantly. We interpreted the early part of the changes in the apparent stiffness as due to peripheral muscle properties. The later part is interpreted as caused by a combination of two processes, a drift in the referent hand coordinate due to the hypothesized back-coupling between the referent and actual hand coordinates and an implicit instruction to keep the hand steady when no changes in robot-generated force took place. The data provide support for the idea of back-coupling between the referent and actual body configurations, which may be an important contributor to stability of motor actions. PMID:26169103

  5. Mechanical testing of internal fixation devices: A theoretical and practical examination of current methods.

    PubMed

    Grant, Caroline A; Schuetz, Michael; Epari, Devakar

    2015-11-26

    Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated interfragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Rotational stiffness of American football shoes affects ankle biomechanics and injury severity.

    PubMed

    Button, Keith D; Braman, Jerrod E; Davison, Mark A; Wei, Feng; Schaeffer, Maureen C; Haut, Roger C

    2015-06-01

    While previous studies have investigated the effect of shoe-surface interaction on injury risk, few studies have examined the effect of rotational stiffness of the shoe. The hypothesis of the current study was that ankles externally rotated to failure in shoes with low rotational stiffness would allow more talus eversion than those in shoes with a higher rotational stiffness, resulting in less severe injury. Twelve (six pairs) cadaver lower extremities were externally rotated to gross failure while positioned in 20 deg of pre-eversion and 20 deg of predorsiflexion by fixing the distal end of the foot, axially loading the proximal tibia, and internally rotating the tibia. One ankle in each pair was constrained by an American football shoe with a stiff upper, while the other was constrained by an American football shoe with a flexible upper. Experimental bone motions were input into specimen-specific computational models to examine levels of ligament elongation to help understand mechanisms of ankle joint failure. Ankles in flexible shoes allowed 6.7±2.4 deg of talus eversion during rotation, significantly greater than the 1.7±1.0 deg for ankles in stiff shoes (p = 0.01). The significantly greater eversion in flexible shoes was potentially due to a more natural response of the ankle during rotation, possibly affecting the injuries that were produced. All ankles failed by either medial ankle injury or syndesmotic injury, or a combination of both. Complex (more than one ligament or bone) injuries were noted in 4 of 6 ankles in stiff shoes and 1 of 6 ankles in flexible shoes. Ligament elongations from the computational model validated the experimental injury data. The current study suggested flexibility (or rotational stiffness) of the shoe may play an important role in both the severity of ankle injuries for athletes.

  7. Multi-field coupled sensing network for health monitoring of composite bolted joint

    NASA Astrophysics Data System (ADS)

    Wang, Yishou; Qing, Xinlin; Dong, Liang; Banerjee, Sourav

    2016-04-01

    Advanced fiber reinforced composite materials are becoming the main structural materials of next generation of aircraft because of their high strength and stiffness to weight ratios, and excellent designability. As key components of large composite structures, joints play important roles to ensure the integrity of the composite structures. However, it is very difficult to analyze the strength and failure modes of composite joints due to their complex nonlinear coupling factors. Therefore, there is a need to monitor, diagnose, evaluate and predict the structure state of composite joints. This paper proposes a multi-field coupled sensing network for health monitoring of composite bolted joints. Major work of this paper includes: 1) The concept of multifunctional sensor layer integrated with eddy current sensors, Rogowski coil and arrayed piezoelectric sensors; 2) Development of the process for integrating the eddy current sensor foil, Rogowski coil and piezoelectric sensor array in multifunctional sensor layer; 3) A new concept of smart composite joint with multifunctional sensing capability. The challenges for building such a structural state sensing system and some solutions to address the challenges are also discussed in the study.

  8. Structural characterization of a first-generation articulated-truss joint for space crane application

    NASA Technical Reports Server (NTRS)

    Sutter, Thomas R.; Wu, K. Chauncey; Riutort, Kevin T.; Laufer, Joseph B.; Phelps, James E.

    1992-01-01

    A first-generation space crane articulated-truss joint was statically and dynamically characterized in a configuration that approximated an operational environment. The articulated-truss joint was integrated into a test-bed for structural characterization. Static characterization was performed by applying known loads and measuring the corresponding deflections to obtain load-deflection curves. Dynamic characterization was performed using modal testing to experimentally determine the first six mode shapes, frequencies, and modal damping values. Static and dynamic characteristics were also determined for a reference truss that served as a characterization baseline. Load-deflection curves and experimental frequency response functions are presented for the reference truss and the articulated-truss joint mounted in the test-bed. The static and dynamic experimental results are compared with analytical predictions obtained from finite element analyses. Load-deflection response is also presented for one of the linear actuators used in the articulated-truss joint. Finally, an assessment is presented for the predictability of the truss hardware used in the reference truss and articulated-truss joint based upon hardware stiffness properties that were previously obtained during the Precision Segmented Reflector (PSR) Technology Development Program.

  9. Dietary variation and mechanical properties of articular cartilage in the temporomandibular joint: implications for the role of plasticity in mechanobiology and pathobiology.

    PubMed

    Ravosa, Matthew J; Kane, Robert J

    2017-10-01

    Due to their nature as tissue composites, skeletal joints pose an additional challenge in terms of evaluating the functional significance of morphological variation in their bony and cartilaginous components in response to altered loading conditions. Arguably, this complexity requires more direct means of investigating joint plasticity and performance than typically employed to analyze macro- and micro-anatomical phenomena. To address a significant gap in our understanding of the plasticity of the mammalian temporomandibular joint (TMJ), we investigated the histology and mechanical properties of condylar articular cartilage in rabbits subjected to long-term variation in diet-induced masticatory stresses, specifically cyclical loading. Three cohorts of male weanlings were raised for six months on different diets until adulthood. Following euthanasia, the TMJ condyles on one side were dissected away, fixed, decalcified, dehydrated, embedded and sectioned. Safranin O staining was employed to identify variation in proteoglycan content, which in turn was used to predict patterns of articular cartilage stiffness in contralateral condylar specimens for each treatment group. Hematoxylin and eosin staining was used to quantify diet-induced changes in chondrocyte hypertrophy and cellularity. Mechanical tests document significant decreases in articular cartilage stiffness corresponding to patterns of extracellular matrix relative protein abundance in rabbits subjected to greater cyclical loading. This indicates that TMJs routinely subjected to higher masticatory stresses due to a challenging diet eventually develop postnatal decreases in the ability to counter compressive loads during postcanine biting and chewing. These findings provide novel information regarding TMJ performance, with broader implications about the costs and benefits of phenotypic plasticity as well as implications for how such biological processes affect connective tissue mechanobiology and pathobiology. Copyright © 2017 Elsevier GmbH. All rights reserved.

  10. Midtarsal locking, the windlass mechanism, and running strike pattern: A kinematic and kinetic assessment.

    PubMed

    Bruening, Dustin A; Pohl, Michael B; Takahashi, Kota Z; Barrios, Joaquin A

    2018-05-17

    Changes in running strike pattern affect ankle and knee mechanics, but little is known about the influence of strike pattern on the joints distal to the ankle. The purpose of this study was to explore the effects of forefoot strike (FFS) and rearfoot strike (RFS) running patterns on foot kinematics and kinetics, from the perspectives of the midtarsal locking theory and the windlass mechanism. Per the midtarsal locking theory, we hypothesized that the ankle would be more inverted in early stance when using a FFS, resulting in decreased midtarsal joint excursions and increased dynamic stiffness. Associated with a more engaged windlass mechanism, we hypothesized that a FFS would elicit increased metatarsophalangeal joint excursions and negative work in late stance. Eighteen healthy female runners ran overground with both FFS and RFS patterns. Instrumented motion capture and a validated multi-segment foot model were used to analyze midtarsal and metatarsophalangeal joint kinematics and kinetics. During early stance in FFS the ankle was more inverted, with concurrently decreased midtarsal eversion (p < 0.001) and abduction excursions (p = 0.003) but increased dorsiflexion excursion (p = 0.005). Dynamic midtarsal stiffness did not differ (p = 0.761). During late stance in FFS, metatarsophalangeal extension was increased (p = 0.009), with concurrently increased negative work (p < 0.001). In addition, there was simultaneously increased midtarsal positive work (p < 0.001), suggesting enhanced power transfer in FFS. Clear evidence for the presence of midtarsal locking was not observed in either strike pattern during running. However, the windlass mechanism appeared to be engaged to a greater extent during FFS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Relationship between activation of ankle muscles and quasi-joint stiffness in early and middle stances during gait in patients with hemiparesis.

    PubMed

    Sekiguchi, Yusuke; Muraki, Takayuki; Tanaka, Naofumi; Izumi, Shin-Ichi

    2015-09-01

    It is unclear whether muscle contraction is necessary to increase quasi-joint stiffness (QJS) of the ankle joint during gait in patients with hemiparesis. The purpose of the present study was to investigate the relationship between QJS and muscle activation at the ankle joint in the stance phase during gait in patients with hemiparesis. Spatiotemporal and kinetic gait parameters and activation of the medial head of the gastrocnemius (MG), soleus (SOL), and tibialis anterior (TA) muscles were measured using a 3-dimensional motion analysis system and surface electromyography, in 21 patients with hemiparesis due to stroke and 10 healthy individuals. In the early stance, the QJS on the paretic side (PS) of patients was greater than that on the non-PS (p<0.05) and not significantly correlated with activation of the three muscles. In the middle stance, the QJS on the PS was lower than that on the non-PS (p<0.05) and that on the right side of controls (p<0.001), which was positively correlated with activation of the MG (r=0.51, p<0.05) and SOL (r=0.49, p<0.05). In the patients with hemiparesis, plantarflexor activation may not contribute to QJS in the early stance. On the other hand, QJS in the middle stance may be attributed to activation of the MG and SOL. Our findings suggest that activation of the MG and SOL in the middle stance on the PS may require to be enhanced to increase QJS during gait in patients with hemiparesis. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Vibration Control Using a State Observer that Considers Disturbances of a Golf Swing Robot

    NASA Astrophysics Data System (ADS)

    Hoshino, Yohei; Kobayashi, Yukinori; Yamada, Gen

    In this paper, optimal control of a golf swing robot that is used to evaluate the performance of golf clubs is described. The robot has two joints, a rigid link and a flexible link that is a golf club. A mathematical model of the golf club is derived by Hamilton’s principle in consideration of bending and torsional stiffness and in consideration of eccentricity of the center of gravity of the club head on the shaft axis. A linear quadratic regulator (LQR) that considers the vibration of the club shaft is used to stop the robot during the follow-through. Since the robot moves fast and has strong non-linearity, an ordinary state observer for a linear system cannot accurately estimate the states of the system. A state observer that considers disturbances accurately estimates the state variables that cannot be measured. The results of numerical simulation are compared with experimental results obtained by using a swing robot.

  13. Relationships of density, microfibril angle, and sound velocity with stiffness and strength in mature wood of Douglas-fir

    Treesearch

    B. Lachenbruch; G.R. Johnson; G.M. Downes; R. Evans

    2010-01-01

    The relative importance of density, acoustic velocity, and microfibril angle (MFA) for the prediction of stiffness (MOE) and strength (MOR) has not been well established for Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco). MOE and MOR of small clear specimens of mature wood were better predicted by density and velocity than by either variable...

  14. A preliminary case series evaluating the safety and immediate to short-term clinical benefits of joint mobilization in hemophilic arthritis of the lower limb.

    PubMed

    Scaddan, Emma; Rowell, John; O'Leary, Shaun

    2017-09-01

    Arthritis resulting from recurrent intra-articular bleeding in individuals with hemophilia can be severely debilitating due to joint pain and stiffness with subsequent loss of mobility and function. Very limited studies have investigated the potential benefits of joint mobilization for this condition. This case series is a preliminary investigation of safety, as well as immediate and short-term clinical benefits, associated with gentle knee and ankle joint mobilization in people with hemophilic arthropathy. A single intervention of joint mobilization was applied to the affected knees and/or ankles of 16 individuals with severe or moderate hemophilia within a public hospital setting. Adverse events, as well as immediate (pain-free passive joint range, Timed Up and Go Test with maximum pain numerical rating scale) and short-term (Lower Extremity Functional Scale) effects of the intervention were evaluated with a repeated measures ANOVA. There were no adverse events. An immediate significant increase was observed in pain-free passive ankle joint range of motion ( p  < 0.05) following the joint mobilization intervention. The findings of this case series suggest that gentle joint mobilization techniques may be safely considered as part of a multimodal management approach for hemophilic arthropathy.

  15. [Clinical randomized study of bee-sting therapy for rheumatoid arthritis].

    PubMed

    Liu, Xi-De; Zhang, Jin-Lu; Zheng, Han-Guang; Liu, Feng-Yun; Chen, Ying

    2008-06-01

    To observe the clinical effect of bee-sting (venom) therapy in the treatment of rheumatoid arthritis (RA). One hundred RA patients were randomly divided into medication (control) group and bee-venom group, with 50 cases in each. Patients of control group were treated with oral administration of Methotrexate (MTX, 7.5 mg/w), Sulfasalazine (0.5 g,t. i.d.), Meloxicam (Mobic,7. 5 mg, b. i. d.); and those of bee-venom group treated with Bee-sting of Ashi-points and the above-mentioned Western medicines. Ashi-points were selected according to the position of RA and used as the main acupoints, supplemented with other acupoints according to syndrome differentiation. The treatment was given once every other day and all the treatments lasted for 3 months. Compared with pre-treatment, scores of joint swelling degree, joint activity, pain, and pressing pain, joint-swelling number, grasp force, 15 m-walking duration, morning stiff duration in bee-venom group and medication group were improved significantly (P<0.05, 0.01). Comparison between two groups showed that after the therapy, scores of joint swelling, pain and pressing pain, joint-swelling number and morning stiff duration, and the doses of the administered MTX and Mobic in bee-venom group were all significantly lower than those in medication group (P<0.05, 0.01); whereas the grasp force in been-venom group was markedly higher than that in medication group (P<0.05). In addition, the relapse rate of bee-venom group was obviously lower than that of medication group (P<0.05; 12% vs 32%). Combined application of bee-venom therapy and medication is superior to simple use of medication in relieving RA, and when bee-sting therapy used, the commonly-taken doses of western medicines may be reduced, and the relapse rate gets lower.

  16. Multivariable Dynamic Ankle Mechanical Impedance With Relaxed Muscles

    PubMed Central

    Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville

    2015-01-01

    Neurological or biomechanical disorders may distort ankle mechanical impedance and thereby impair locomotor function. This paper presents a quantitative characterization of multivariable ankle mechanical impedance of young healthy subjects when their muscles were relaxed, to serve as a baseline to compare with pathophysiological ankle properties of biomechanically and/or neurologically impaired patients. Measurements using a highly backdrivable wearable ankle robot combined with multi-input multi-output stochastic system identification methods enabled reliable characterization of ankle mechanical impedance in two degrees-of-freedom (DOFs) simultaneously, the sagittal and frontal planes. The characterization included important ankle properties unavailable from single DOF studies: coupling between DOFs and anisotropy as a function of frequency. Ankle impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness in both seated (knee flexed) and standing (knee straightened) postures. Stiffness in the sagittal plane was greater than in the frontal plane and furthermore, was greater when standing than when seated, most likely due to the stretch of bi-articular muscles (medial and lateral gastrocnemius). Very low off-diagonal partial coherences implied negligible coupling between dorsiflexion-plantarflexion and inversion-eversion. The directions of principal axes were tilted slightly counterclockwise from the original joint coordinates. The directional variation (anisotropy) of ankle impedance in the 2-D space formed by rotations in the sagittal and frontal planes exhibited a characteristic “peanut” shape, weak in inversion-eversion over a wide range of frequencies from the stiffness dominated region up to the inertia dominated region. Implications for the assessment of neurological and biomechanical impairments are discussed. PMID:24686292

  17. Olympic weightlifting training causes different knee muscle-coactivation adaptations compared with traditional weight training.

    PubMed

    Arabatzi, Fotini; Kellis, Eleftherios

    2012-08-01

    The purpose of this study was to compare the effects of an Olympic weightlifting (OL) and traditional weight (TW) training program on muscle coactivation around the knee joint during vertical jump tests. Twenty-six men were assigned randomly to 3 groups: the OL (n = 9), the TW (n = 9), and Control (C) groups (n = 8). The experimental groups trained 3 d · wk(-1) for 8 weeks. Electromyographic (EMG) activity from the rectus femoris and biceps femoris, sagittal kinematics, vertical stiffness, maximum height, and power were collected during the squat jump, countermovement jump (CMJ), and drop jump (DJ), before and after training. Knee muscle coactivation index (CI) was calculated for different phases of each jump by dividing the antagonist EMG activity by the agonist. Analysis of variance showed that the CI recorded during the preactivation and eccentric phases of all the jumps increased in both training groups. The OL group showed a higher stiffness and jump height adaptation than the TW group did (p < 0.05). Further, the OL showed a decrease or maintenance of the CI recorded during the propulsion phase of the CMJ and DJs, which is in contrast to the increase in the CI observed after TW training (p < 0.05). The results indicated that the altered muscle activation patterns about the knee, coupled with changes of leg stiffness, differ between the 2 programs. The OL program improves jump performance via a constant CI, whereas the TW training caused an increased CI, probably to enhance joint stability.

  18. Correlation between Mechanical Properties of the Ankle Muscles and Postural Sway during the Menstrual Cycle.

    PubMed

    Yim, JongEun; Petrofsky, Jerrold; Lee, Haneul

    2018-03-01

    Ankle and foot injuries are common among athletes and physically active individuals. The most common residual disability, ankle sprain, is characterized by instability along with postural sway. If the supporting structures around a joint become lax, posture stability and balance are also affected. Previous studies have examined muscle stiffness and elasticity and postural sway separately; however, the relationship between these factors is yet unknown. It is well known that the levels of sex hormones, especially estrogen, change in women over the phase of the menstrual cycle. Therefore, this study examined the relationship between the mechanical properties of tissue and balance activity using a non-invasive digital palpation device to determine if they undergo any changes over the menstrual cycle in young women. Sixteen young women with regular menstrual cycles completed the study. Tone, stiffness, and elasticity of the ankle muscles (lateral gastrocnemius, peroneus longus, and tibialis anterior) were measured using a non-invasive digital palpation device. Postural sway was recorded while the participants performed balance tasks during ovulation and menstruation. Significantly greater posture sway characteristics and ankle muscle elasticity were found during ovulation than during menstruation; lower tone and stiffness of the ankle muscles were observed at ovulation (p < 0.05). Additionally, weak-to-strong relationships between ankle muscle mechanical properties and postural sway characteristics were found (p < 0.05). These results suggest the effect of estrogen on human connective tissues. We therefore postulate that estrogen increases joint and muscle laxity and affects posture stability according to the phase of the menstrual cycle.

  19. Multivariable dynamic ankle mechanical impedance with relaxed muscles.

    PubMed

    Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville

    2014-11-01

    Neurological or biomechanical disorders may distort ankle mechanical impedance and thereby impair locomotor function. This paper presents a quantitative characterization of multivariable ankle mechanical impedance of young healthy subjects when their muscles were relaxed, to serve as a baseline to compare with pathophysiological ankle properties of biomechanically and/or neurologically impaired patients. Measurements using a highly backdrivable wearable ankle robot combined with multi-input multi-output stochastic system identification methods enabled reliable characterization of ankle mechanical impedance in two degrees-of-freedom (DOFs) simultaneously, the sagittal and frontal planes. The characterization included important ankle properties unavailable from single DOF studies: coupling between DOFs and anisotropy as a function of frequency. Ankle impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness in both seated (knee flexed) and standing (knee straightened) postures. Stiffness in the sagittal plane was greater than in the frontal plane and furthermore, was greater when standing than when seated, most likely due to the stretch of bi-articular muscles (medial and lateral gastrocnemius). Very low off-diagonal partial coherences implied negligible coupling between dorsiflexion-plantarflexion and inversion-eversion. The directions of principal axes were tilted slightly counterclockwise from the original joint coordinates. The directional variation (anisotropy) of ankle impedance in the 2-D space formed by rotations in the sagittal and frontal planes exhibited a characteristic "peanut" shape, weak in inversion-eversion over a wide range of frequencies from the stiffness dominated region up to the inertia dominated region. Implications for the assessment of neurological and biomechanical impairments are discussed.

  20. Cardiac Organ Damage and Arterial Stiffness in Autonomic Failure: Comparison With Essential Hypertension.

    PubMed

    Milazzo, Valeria; Maule, Simona; Di Stefano, Cristina; Tosello, Francesco; Totaro, Silvia; Veglio, Franco; Milan, Alberto

    2015-12-01

    Autonomic failure (AF) is characterized by orthostatic hypotension, supine hypertension, and increased blood pressure (BP) variability. AF patients develop cardiac organ damage, similarly to essential hypertension (EH), and have higher arterial stiffness than healthy controls. Determinants of cardiovascular organ damage in AF are not well known: both BP variability and mean BP values may be involved. The aim of the study was to evaluate cardiac organ damage, arterial stiffness, and central hemodynamics in AF, compared with EH subjects with similar 24-hour BP and a group of healthy controls, and to evaluate determinants of target organ damage in patients with AF. Twenty-seven patients with primary AF were studied (mean age, 65.7±11.2 years) using transthoracic echocardiography, carotid-femoral pulse wave velocity, central hemodynamics, and 24-hour ambulatory BP monitoring. They were compared with 27 EH subjects matched for age, sex, and 24-hour mean BP and with 27 healthy controls. AF and EH had similar left ventricular mass (101.6±33.3 versus 97.7±28.1 g/m(2), P=0.59) and carotid-femoral pulse wave velocity (9.3±1.8 versus 9.2±3.0 m/s, P=0.93); both parameters were significantly lower in healthy controls (P<0.01). Compared with EH, AF patients had higher augmentation index (31.0±7.6% versus 26.1±9.2%, P=0.04) and central BP values. Nighttime systolic BP and 24-hour systolic BP predicted organ damage, independent of BP variability. AF patients develop hypertensive heart disease and increased arterial stiffness, similar to EH with comparable mean BP values. Twenty-four-hour and nighttime systolic BP were determinants of cardiovascular damage, independent of BP variability. © 2015 American Heart Association, Inc.

Top